SLAC Magnetic Measurements Date: 10-21-2020 Time: 12:24:08 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_003_Cell_34 Serial Number: PC33408 Run Number: 11 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 11 12:24:26 Ambient Measurement Device(s) Being Used, type = None 12:24:26 Magnet Voltage Measurement Device(s) Being Used, type = None 12:24:26 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:24:26 XMAG Device(s) Being Used, type = None 12:24:26 Ambient Measurement Device(s) Being Used, type = None 12:24:28   Voltage Measurement, V = 0.000000 V 12:24:29 Temperature Measurement, Probe Number = 0, T = 21.009000 C 12:24:29 Temperature Measurement, Probe Number = 1, T = 20.375000 C 12:24:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.01 P2 = 3458_Meas_Junction, Value = 20.38 12:24:29 Integrated Voltage Measurement... 12:24:59 Voltage Offset Correction: v_off_ini = -0.000000235 V, v_off_fin = -0.000001463 V 12:24:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142377933 Vs 12:24:59 Integrated Voltage Measurement... 12:25:35 Voltage Offset Correction: v_off_ini = 0.000000037 V, v_off_fin = -0.000001333 V 12:25:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142381690 Vs 12:25:36   Voltage Measurement, V = 0.000000 V 12:25:36 Temperature Measurement, Probe Number = 0, T = 21.004000 C 12:25:37 Temperature Measurement, Probe Number = 1, T = 20.639000 C 12:25:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.00 P2 = 3458_Meas_Junction, Value = 20.64 12:25:37 Integrated Voltage Measurement... 12:26:08 Voltage Offset Correction: v_off_ini = -0.000000678 V, v_off_fin = 0.000000588 V 12:26:08 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142377965 Vs 12:26:08 Integrated Voltage Measurement... 12:26:42 Voltage Offset Correction: v_off_ini = -0.000000101 V, v_off_fin = -0.000001753 V 12:26:42 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142376731 Vs 12:26:43   Voltage Measurement, V = 0.000000 V 12:26:43 Temperature Measurement, Probe Number = 0, T = 21.016000 C 12:26:44 Temperature Measurement, Probe Number = 1, T = 20.727000 C 12:26:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 20.73 12:26:44 Integrated Voltage Measurement... 12:27:16 Voltage Offset Correction: v_off_ini = -0.000000883 V, v_off_fin = -0.000000368 V 12:27:16 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142385384 Vs 12:27:16 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = -0.000000278 V, v_off_fin = -0.000001785 V 12:27:47 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142372815 Vs 12:27:48   Voltage Measurement, V = 0.000000 V 12:27:49 Temperature Measurement, Probe Number = 0, T = 21.025000 C 12:27:49 Temperature Measurement, Probe Number = 1, T = 20.557000 C 12:27:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 20.56 12:27:49 Integrated Voltage Measurement... 12:28:24 Voltage Offset Correction: v_off_ini = -0.000000867 V, v_off_fin = 0.000000583 V 12:28:24 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142388924 Vs 12:28:24 Integrated Voltage Measurement... 12:28:56 Voltage Offset Correction: v_off_ini = -0.000000359 V, v_off_fin = -0.000002079 V 12:28:56 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142372971 Vs 12:28:57   Voltage Measurement, V = 0.000000 V 12:28:57 Temperature Measurement, Probe Number = 0, T = 21.019000 C 12:28:58 Temperature Measurement, Probe Number = 1, T = 20.521000 C 12:28:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 20.52 12:28:58 Integrated Voltage Measurement... 12:29:29 Voltage Offset Correction: v_off_ini = -0.000000980 V, v_off_fin = 0.000000328 V 12:29:30 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142390051 Vs 12:29:30 Integrated Voltage Measurement... 12:30:02 Voltage Offset Correction: v_off_ini = -0.000000225 V, v_off_fin = -0.000002118 V 12:30:02 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142371382 Vs 12:30:03   Voltage Measurement, V = 0.000000 V 12:30:04 Temperature Measurement, Probe Number = 0, T = 21.028000 C 12:30:05 Temperature Measurement, Probe Number = 1, T = 20.521000 C 12:30:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 20.52 12:30:05 Integrated Voltage Measurement... 12:30:38 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = 0.000000018 V 12:30:38 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.142387624 Vs 12:30:38 Integrated Voltage Measurement... 12:31:10 Voltage Offset Correction: v_off_ini = -0.000000202 V, v_off_fin = -0.000001687 V 12:31:10 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142359874 Vs 12:31:11   Voltage Measurement, V = 0.000000 V 12:31:11 Temperature Measurement, Probe Number = 0, T = 21.030000 C 12:31:12 Temperature Measurement, Probe Number = 1, T = 20.437000 C 12:31:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 20.44 12:31:12 Integrated Voltage Measurement... 12:31:44 Voltage Offset Correction: v_off_ini = -0.000000793 V, v_off_fin = -0.000001287 V 12:31:44 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142378235 Vs 12:31:45 Integrated Voltage Measurement... 12:32:17 Voltage Offset Correction: v_off_ini = -0.000000182 V, v_off_fin = -0.000001570 V 12:32:17 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142369420 Vs 12:32:18   Voltage Measurement, V = 0.000000 V 12:32:18 Temperature Measurement, Probe Number = 0, T = 21.027000 C 12:32:19 Temperature Measurement, Probe Number = 1, T = 20.437000 C 12:32:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 20.44 12:32:19 Integrated Voltage Measurement... 12:32:52 Voltage Offset Correction: v_off_ini = -0.000000913 V, v_off_fin = -0.000000469 V 12:32:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142387664 Vs 12:32:52 Integrated Voltage Measurement... 12:33:23 Voltage Offset Correction: v_off_ini = -0.000000368 V, v_off_fin = -0.000001525 V 12:33:23 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142363380 Vs 12:33:24   Voltage Measurement, V = 0.000000 V 12:33:25 Temperature Measurement, Probe Number = 0, T = 21.029000 C 12:33:26 Temperature Measurement, Probe Number = 1, T = 20.398000 C 12:33:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.03 P2 = 3458_Meas_Junction, Value = 20.40 12:33:26 Integrated Voltage Measurement... 12:33:57 Voltage Offset Correction: v_off_ini = -0.000000950 V, v_off_fin = -0.000000040 V 12:33:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142378411 Vs 12:33:57 Integrated Voltage Measurement... 12:34:30 Voltage Offset Correction: v_off_ini = -0.000000288 V, v_off_fin = -0.000001231 V 12:34:30 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142370874 Vs 12:34:31   Voltage Measurement, V = 0.000000 V 12:34:31 Temperature Measurement, Probe Number = 0, T = 21.016000 C 12:34:32 Temperature Measurement, Probe Number = 1, T = 20.379000 C 12:34:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.02 P2 = 3458_Meas_Junction, Value = 20.38 12:34:32 Integrated Voltage Measurement... 12:35:04 Voltage Offset Correction: v_off_ini = -0.000000983 V, v_off_fin = -0.000000082 V 12:35:04 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142390563 Vs 12:35:04 Integrated Voltage Measurement... 12:35:36 Voltage Offset Correction: v_off_ini = -0.000000408 V, v_off_fin = -0.000002418 V 12:35:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142360437 Vs