SLAC Magnetic Measurements Date: 09-09-2020 Time: 18:27:06 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_002_Cell_41_Upstairs Serial Number: PC97084 Run Number: 1 Measurement Device: WalkerVS Operator: sda Comment: Coil Integral measurement upstairs, cable straight into 3458A. Set 1 18:27:09 Ambient Measurement Device(s) Being Used, type = None 18:27:09 Magnet Voltage Measurement Device(s) Being Used, type = None 18:27:09 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 18:27:09 XMAG Device(s) Being Used, type = None 18:27:09 Ambient Measurement Device(s) Being Used, type = None 18:27:17   Voltage Measurement, V = 0.000000 V 18:27:18 Temperature Measurement, Probe Number = 0, T = 27.017000 C 18:27:18 Temperature Measurement, Probe Number = 1, T = 27.014000 C 18:27:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.02 P2 = 3458_Meas_Junction, Value = 27.01 18:27:18 Integrated Voltage Measurement... 18:27:51 Voltage Offset Correction: v_off_ini = 0.000003985 V, v_off_fin = 0.000005204 V 18:27:51 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.141522777 Vs 18:27:51 Integrated Voltage Measurement... 18:28:24 Voltage Offset Correction: v_off_ini = 0.000005067 V, v_off_fin = 0.000003837 V 18:28:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141463280 Vs 18:28:25   Voltage Measurement, V = 0.000000 V 18:28:25 Temperature Measurement, Probe Number = 0, T = 26.996000 C 18:28:26 Temperature Measurement, Probe Number = 1, T = 27.007000 C 18:28:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 27.00 P2 = 3458_Meas_Junction, Value = 27.01 18:28:26 Integrated Voltage Measurement... 18:29:17 Voltage Offset Correction: v_off_ini = 0.000004037 V, v_off_fin = 0.000005561 V 18:29:17 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.141492401 Vs 18:29:17 Integrated Voltage Measurement... 18:29:55 Voltage Offset Correction: v_off_ini = 0.000004813 V, v_off_fin = 0.000002666 V 18:29:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141473064 Vs 18:29:56   Voltage Measurement, V = 0.000000 V 18:29:56 Temperature Measurement, Probe Number = 0, T = 26.990000 C 18:29:57 Temperature Measurement, Probe Number = 1, T = 26.992000 C 18:29:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 26.99 18:29:57 Integrated Voltage Measurement... 18:30:34 Voltage Offset Correction: v_off_ini = 0.000003612 V, v_off_fin = 0.000005524 V 18:30:34 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.141499908 Vs 18:30:34 Integrated Voltage Measurement... 18:31:08 Voltage Offset Correction: v_off_ini = 0.000004704 V, v_off_fin = 0.000002915 V 18:31:08 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141470730 Vs 18:31:10   Voltage Measurement, V = 0.000000 V 18:31:10 Temperature Measurement, Probe Number = 0, T = 26.993000 C 18:31:11 Temperature Measurement, Probe Number = 1, T = 26.991000 C 18:31:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 26.99 18:31:11 Integrated Voltage Measurement... 18:31:42 Voltage Offset Correction: v_off_ini = 0.000003262 V, v_off_fin = 0.000004817 V 18:31:42 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141496766 Vs 18:31:42 Integrated Voltage Measurement... 18:32:21 Voltage Offset Correction: v_off_ini = 0.000004661 V, v_off_fin = 0.000003392 V 18:32:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141467466 Vs 18:32:22   Voltage Measurement, V = 0.000000 V 18:32:23 Temperature Measurement, Probe Number = 0, T = 26.991000 C 18:32:23 Temperature Measurement, Probe Number = 1, T = 26.989000 C 18:32:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 26.99 18:32:23 Integrated Voltage Measurement... 18:32:54 Voltage Offset Correction: v_off_ini = 0.000003477 V, v_off_fin = 0.000004549 V 18:32:54 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141481151 Vs 18:32:54 Integrated Voltage Measurement... 18:33:26 Voltage Offset Correction: v_off_ini = 0.000004962 V, v_off_fin = 0.000003150 V 18:33:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141464190 Vs 18:33:27   Voltage Measurement, V = 0.000000 V 18:33:27 Temperature Measurement, Probe Number = 0, T = 26.990000 C 18:33:28 Temperature Measurement, Probe Number = 1, T = 26.994000 C 18:33:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 26.99 18:33:28 Integrated Voltage Measurement... 18:34:01 Voltage Offset Correction: v_off_ini = 0.000003751 V, v_off_fin = 0.000005657 V 18:34:01 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141488253 Vs 18:34:01 Integrated Voltage Measurement... 18:34:32 Voltage Offset Correction: v_off_ini = 0.000004799 V, v_off_fin = 0.000002646 V 18:34:32 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141469016 Vs 18:34:33   Voltage Measurement, V = 0.000000 V 18:34:34 Temperature Measurement, Probe Number = 0, T = 26.988000 C 18:34:34 Temperature Measurement, Probe Number = 1, T = 26.995000 C 18:34:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 27.00 18:34:34 Integrated Voltage Measurement... 18:35:06 Voltage Offset Correction: v_off_ini = 0.000003373 V, v_off_fin = 0.000005079 V 18:35:06 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.141503075 Vs 18:35:06 Integrated Voltage Measurement... 18:35:37 Voltage Offset Correction: v_off_ini = 0.000004816 V, v_off_fin = 0.000002665 V 18:35:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141465281 Vs 18:35:38   Voltage Measurement, V = 0.000000 V 18:35:39 Temperature Measurement, Probe Number = 0, T = 26.987000 C 18:35:39 Temperature Measurement, Probe Number = 1, T = 26.999000 C 18:35:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 27.00 18:35:39 Integrated Voltage Measurement... 18:36:11 Voltage Offset Correction: v_off_ini = 0.000003633 V, v_off_fin = 0.000005279 V 18:36:11 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141483627 Vs 18:36:11 Integrated Voltage Measurement... 18:36:49 Voltage Offset Correction: v_off_ini = 0.000004588 V, v_off_fin = 0.000002505 V 18:36:49 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.141469611 Vs 18:36:50   Voltage Measurement, V = 0.000000 V 18:36:50 Temperature Measurement, Probe Number = 0, T = 26.987000 C 18:36:51 Temperature Measurement, Probe Number = 1, T = 27.001000 C 18:36:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.99 P2 = 3458_Meas_Junction, Value = 27.00 18:36:51 Integrated Voltage Measurement... 18:37:21 Voltage Offset Correction: v_off_ini = 0.000003749 V, v_off_fin = 0.000005091 V 18:37:21 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141485727 Vs 18:37:21 Integrated Voltage Measurement... 18:37:51 Voltage Offset Correction: v_off_ini = 0.000005030 V, v_off_fin = 0.000002801 V 18:37:51 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141467954 Vs 18:37:52   Voltage Measurement, V = 0.000000 V 18:37:53 Temperature Measurement, Probe Number = 0, T = 26.983000 C 18:37:54 Temperature Measurement, Probe Number = 1, T = 26.987000 C 18:37:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 26.98 P2 = 3458_Meas_Junction, Value = 26.99 18:37:54 Integrated Voltage Measurement... 18:38:23 Voltage Offset Correction: v_off_ini = 0.000003306 V, v_off_fin = 0.000005710 V 18:38:23 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141491464 Vs 18:38:23 Integrated Voltage Measurement... 18:38:55 Voltage Offset Correction: v_off_ini = 0.000005034 V, v_off_fin = 0.000002831 V 18:38:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141468826 Vs