SLAC Magnetic Measurements Date: 12-02-2020 Time: 15:55:19 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_002_Cell_41 Serial Number: PC33408 Run Number: 14 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full set 14 15:55:37 Ambient Measurement Device(s) Being Used, type = None 15:55:37 Magnet Voltage Measurement Device(s) Being Used, type = None 15:55:37 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:55:37 XMAG Device(s) Being Used, type = None 15:55:37 Ambient Measurement Device(s) Being Used, type = None 15:55:40   Voltage Measurement, V = 0.000000 V 15:55:40 Temperature Measurement, Probe Number = 0, T = 21.288000 C 15:55:41 Temperature Measurement, Probe Number = 1, T = 22.900000 C 15:55:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.29 P2 = 3458_Meas_Junction, Value = 22.90 15:55:41 Integrated Voltage Measurement... 15:56:07 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = 0.000002019 V 15:56:07 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.141468930 Vs 15:56:07 Integrated Voltage Measurement... 15:56:41 Voltage Offset Correction: v_off_ini = 0.000000971 V, v_off_fin = 0.000028761 V 15:56:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141792185 Vs 15:56:42   Voltage Measurement, V = 0.000000 V 15:56:43 Temperature Measurement, Probe Number = 0, T = 21.279000 C 15:56:44 Temperature Measurement, Probe Number = 1, T = 22.929000 C 15:56:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 22.93 15:56:44 Integrated Voltage Measurement... 15:57:45 Voltage Offset Correction: v_off_ini = 0.000000213 V, v_off_fin = 0.000000245 V 15:57:45 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.141478883 Vs 15:57:45 Integrated Voltage Measurement... 15:58:32 Voltage Offset Correction: v_off_ini = 0.000000760 V, v_off_fin = -0.000000229 V 15:58:32 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.141464980 Vs 15:58:33   Voltage Measurement, V = 0.000000 V 15:58:33 Temperature Measurement, Probe Number = 0, T = 21.264000 C 15:58:34 Temperature Measurement, Probe Number = 1, T = 22.971000 C 15:58:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.26 P2 = 3458_Meas_Junction, Value = 22.97 15:58:34 Integrated Voltage Measurement... 15:59:05 Voltage Offset Correction: v_off_ini = -0.000000142 V, v_off_fin = 0.000000993 V 15:59:05 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141471020 Vs 15:59:05 Integrated Voltage Measurement... 15:59:36 Voltage Offset Correction: v_off_ini = 0.000000748 V, v_off_fin = -0.000000747 V 15:59:36 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141458141 Vs 15:59:37   Voltage Measurement, V = 0.000000 V 15:59:38 Temperature Measurement, Probe Number = 0, T = 21.255000 C 15:59:39 Temperature Measurement, Probe Number = 1, T = 22.982000 C 15:59:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.25 P2 = 3458_Meas_Junction, Value = 22.98 15:59:39 Integrated Voltage Measurement... 16:00:12 Voltage Offset Correction: v_off_ini = 0.000000005 V, v_off_fin = 0.000001589 V 16:00:12 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141474082 Vs 16:00:12 Integrated Voltage Measurement... 16:00:42 Voltage Offset Correction: v_off_ini = 0.000001007 V, v_off_fin = -0.000000241 V 16:00:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141461805 Vs 16:00:43   Voltage Measurement, V = 0.000000 V 16:00:44 Temperature Measurement, Probe Number = 0, T = 21.267000 C 16:00:44 Temperature Measurement, Probe Number = 1, T = 22.921000 C 16:00:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.27 P2 = 3458_Meas_Junction, Value = 22.92 16:00:44 Integrated Voltage Measurement... 16:01:14 Voltage Offset Correction: v_off_ini = -0.000000125 V, v_off_fin = 0.000001318 V 16:01:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141464971 Vs 16:01:15 Integrated Voltage Measurement... 16:01:45 Voltage Offset Correction: v_off_ini = 0.000001043 V, v_off_fin = -0.000001042 V 16:01:45 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141455875 Vs 16:01:46   Voltage Measurement, V = 0.000000 V 16:01:47 Temperature Measurement, Probe Number = 0, T = 21.308000 C 16:01:47 Temperature Measurement, Probe Number = 1, T = 22.951000 C 16:01:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.31 P2 = 3458_Meas_Junction, Value = 22.95 16:01:47 Integrated Voltage Measurement... 16:02:18 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = 0.000001466 V 16:02:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141468576 Vs 16:02:18 Integrated Voltage Measurement... 16:02:49 Voltage Offset Correction: v_off_ini = 0.000000883 V, v_off_fin = -0.000001266 V 16:02:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141464147 Vs 16:02:50   Voltage Measurement, V = 0.000000 V 16:02:51 Temperature Measurement, Probe Number = 0, T = 21.310000 C 16:02:51 Temperature Measurement, Probe Number = 1, T = 22.978000 C 16:02:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.31 P2 = 3458_Meas_Junction, Value = 22.98 16:02:51 Integrated Voltage Measurement... 16:03:22 Voltage Offset Correction: v_off_ini = -0.000000054 V, v_off_fin = 0.000001573 V 16:03:22 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141473847 Vs 16:03:22 Integrated Voltage Measurement... 16:03:53 Voltage Offset Correction: v_off_ini = 0.000000808 V, v_off_fin = -0.000001222 V 16:03:53 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.141463601 Vs 16:03:54   Voltage Measurement, V = 0.000000 V 16:03:54 Temperature Measurement, Probe Number = 0, T = 21.295000 C 16:03:55 Temperature Measurement, Probe Number = 1, T = 23.026000 C 16:03:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.30 P2 = 3458_Meas_Junction, Value = 23.03 16:03:55 Integrated Voltage Measurement... 16:04:26 Voltage Offset Correction: v_off_ini = -0.000000128 V, v_off_fin = 0.000001346 V 16:04:26 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141473749 Vs 16:04:26 Integrated Voltage Measurement... 16:04:57 Voltage Offset Correction: v_off_ini = 0.000001030 V, v_off_fin = -0.000000173 V 16:04:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141459651 Vs 16:04:58   Voltage Measurement, V = 0.000000 V 16:04:59 Temperature Measurement, Probe Number = 0, T = 21.283000 C 16:04:59 Temperature Measurement, Probe Number = 1, T = 23.053000 C 16:04:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 23.05 16:04:59 Integrated Voltage Measurement... 16:05:30 Voltage Offset Correction: v_off_ini = -0.000000068 V, v_off_fin = 0.000001258 V 16:05:30 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141465399 Vs 16:05:30 Integrated Voltage Measurement... 16:05:59 Voltage Offset Correction: v_off_ini = 0.000000950 V, v_off_fin = -0.000000588 V 16:06:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141470611 Vs 16:06:01   Voltage Measurement, V = 0.000000 V 16:06:01 Temperature Measurement, Probe Number = 0, T = 21.276000 C 16:06:02 Temperature Measurement, Probe Number = 1, T = 23.052000 C 16:06:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.28 P2 = 3458_Meas_Junction, Value = 23.05 16:06:02 Integrated Voltage Measurement... 16:06:32 Voltage Offset Correction: v_off_ini = -0.000000436 V, v_off_fin = 0.000002476 V 16:06:33 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141481357 Vs 16:06:33 Integrated Voltage Measurement... 16:07:03 Voltage Offset Correction: v_off_ini = 0.000000924 V, v_off_fin = -0.000001634 V 16:07:04 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141458692 Vs