SLAC Magnetic Measurements Date: 11-18-2020 Time: 15:34:10 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_002_Cell_41 Serial Number: PC33408 Run Number: 13 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 13 15:34:27 Ambient Measurement Device(s) Being Used, type = None 15:34:27 Magnet Voltage Measurement Device(s) Being Used, type = None 15:34:28 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:34:28 XMAG Device(s) Being Used, type = None 15:34:28 Ambient Measurement Device(s) Being Used, type = None 15:34:29   Voltage Measurement, V = 0.000000 V 15:34:30 Temperature Measurement, Probe Number = 0, T = 21.480000 C 15:34:31 Temperature Measurement, Probe Number = 1, T = 21.878000 C 15:34:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.48 P2 = 3458_Meas_Junction, Value = 21.88 15:34:31 Integrated Voltage Measurement... 15:34:57 Voltage Offset Correction: v_off_ini = -0.000000507 V, v_off_fin = -0.000000435 V 15:34:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.141543087 Vs 15:34:57 Integrated Voltage Measurement... 15:35:39 Voltage Offset Correction: v_off_ini = -0.000000092 V, v_off_fin = -0.000001563 V 15:35:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141528366 Vs 15:35:40   Voltage Measurement, V = 0.000000 V 15:35:41 Temperature Measurement, Probe Number = 0, T = 21.455000 C 15:35:41 Temperature Measurement, Probe Number = 1, T = 21.898000 C 15:35:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 21.90 15:35:41 Integrated Voltage Measurement... 15:36:14 Voltage Offset Correction: v_off_ini = -0.000001035 V, v_off_fin = 0.000001084 V 15:36:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141528802 Vs 15:36:14 Integrated Voltage Measurement... 15:36:45 Voltage Offset Correction: v_off_ini = 0.000000057 V, v_off_fin = -0.000001850 V 15:36:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141527011 Vs 15:36:46   Voltage Measurement, V = 0.000000 V 15:36:46 Temperature Measurement, Probe Number = 0, T = 21.441000 C 15:36:47 Temperature Measurement, Probe Number = 1, T = 21.894000 C 15:36:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.44 P2 = 3458_Meas_Junction, Value = 21.89 15:36:47 Integrated Voltage Measurement... 15:37:18 Voltage Offset Correction: v_off_ini = -0.000001390 V, v_off_fin = -0.000001373 V 15:37:18 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141535989 Vs 15:37:18 Integrated Voltage Measurement... 15:37:48 Voltage Offset Correction: v_off_ini = -0.000000132 V, v_off_fin = -0.000002736 V 15:37:48 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141522149 Vs 15:37:49   Voltage Measurement, V = 0.000000 V 15:37:50 Temperature Measurement, Probe Number = 0, T = 21.433000 C 15:37:50 Temperature Measurement, Probe Number = 1, T = 21.906000 C 15:37:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 21.91 15:37:50 Integrated Voltage Measurement... 15:38:21 Voltage Offset Correction: v_off_ini = -0.000001323 V, v_off_fin = 0.000001274 V 15:38:21 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141529988 Vs 15:38:21 Integrated Voltage Measurement... 15:38:51 Voltage Offset Correction: v_off_ini = -0.000000138 V, v_off_fin = -0.000001637 V 15:38:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141520893 Vs 15:38:53   Voltage Measurement, V = 0.000000 V 15:38:53 Temperature Measurement, Probe Number = 0, T = 21.428000 C 15:38:54 Temperature Measurement, Probe Number = 1, T = 21.914000 C 15:38:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 21.91 15:38:54 Integrated Voltage Measurement... 15:39:25 Voltage Offset Correction: v_off_ini = -0.000001475 V, v_off_fin = 0.000000042 V 15:39:25 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141542262 Vs 15:39:25 Integrated Voltage Measurement... 15:40:00 Voltage Offset Correction: v_off_ini = -0.000000111 V, v_off_fin = -0.000000951 V 15:40:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141517918 Vs 15:40:01   Voltage Measurement, V = 0.000000 V 15:40:01 Temperature Measurement, Probe Number = 0, T = 21.422000 C 15:40:02 Temperature Measurement, Probe Number = 1, T = 21.915000 C 15:40:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 21.91 15:40:02 Integrated Voltage Measurement... 15:40:35 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000000395 V 15:40:35 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.141534754 Vs 15:40:35 Integrated Voltage Measurement... 15:41:06 Voltage Offset Correction: v_off_ini = -0.000000045 V, v_off_fin = -0.000002219 V 15:41:06 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141521467 Vs 15:41:07   Voltage Measurement, V = 0.000000 V 15:41:07 Temperature Measurement, Probe Number = 0, T = 21.419000 C 15:41:08 Temperature Measurement, Probe Number = 1, T = 21.924000 C 15:41:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.42 P2 = 3458_Meas_Junction, Value = 21.92 15:41:08 Integrated Voltage Measurement... 15:41:42 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = 0.000000190 V 15:41:42 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141535029 Vs 15:41:42 Integrated Voltage Measurement... 15:42:13 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000001768 V 15:42:13 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141515315 Vs 15:42:14   Voltage Measurement, V = 0.000000 V 15:42:14 Temperature Measurement, Probe Number = 0, T = 21.426000 C 15:42:15 Temperature Measurement, Probe Number = 1, T = 21.940000 C 15:42:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 21.94 15:42:15 Integrated Voltage Measurement... 15:42:56 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = 0.000001422 V 15:42:56 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.141545887 Vs 15:42:56 Integrated Voltage Measurement... 15:43:29 Voltage Offset Correction: v_off_ini = -0.000000114 V, v_off_fin = -0.000002055 V 15:43:29 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141518125 Vs 15:43:30   Voltage Measurement, V = 0.000000 V 15:43:30 Temperature Measurement, Probe Number = 0, T = 21.442000 C 15:43:31 Temperature Measurement, Probe Number = 1, T = 21.944000 C 15:43:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.44 P2 = 3458_Meas_Junction, Value = 21.94 15:43:31 Integrated Voltage Measurement... 15:44:04 Voltage Offset Correction: v_off_ini = -0.000001173 V, v_off_fin = -0.000000676 V 15:44:04 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141533410 Vs 15:44:04 Integrated Voltage Measurement... 15:44:42 Voltage Offset Correction: v_off_ini = 0.000000127 V, v_off_fin = -0.000003139 V 15:44:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141517779 Vs 15:44:43   Voltage Measurement, V = 0.000000 V 15:44:44 Temperature Measurement, Probe Number = 0, T = 21.430000 C 15:44:45 Temperature Measurement, Probe Number = 1, T = 21.965000 C 15:44:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 21.96 15:44:45 Integrated Voltage Measurement... 15:45:17 Voltage Offset Correction: v_off_ini = -0.000001321 V, v_off_fin = 0.000000479 V 15:45:17 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.141545209 Vs 15:45:17 Integrated Voltage Measurement... 15:45:47 Voltage Offset Correction: v_off_ini = 0.000000043 V, v_off_fin = -0.000001183 V 15:45:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141517550 Vs