SLAC Magnetic Measurements Date: 10-29-2020 Time: 15:27:37 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_002_Cell_41 Serial Number: PC33408 Run Number: 12 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 12 15:27:55 Ambient Measurement Device(s) Being Used, type = None 15:27:55 Magnet Voltage Measurement Device(s) Being Used, type = None 15:27:55 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:27:56 XMAG Device(s) Being Used, type = None 15:27:56 Ambient Measurement Device(s) Being Used, type = None 15:27:57   Voltage Measurement, V = 0.000000 V 15:27:58 Temperature Measurement, Probe Number = 0, T = 21.452000 C 15:27:59 Temperature Measurement, Probe Number = 1, T = 22.389000 C 15:27:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.39 15:27:59 Integrated Voltage Measurement... 15:28:25 Voltage Offset Correction: v_off_ini = -0.000000081 V, v_off_fin = 0.000001765 V 15:28:25 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.141492040 Vs 15:28:25 Integrated Voltage Measurement... 15:28:56 Voltage Offset Correction: v_off_ini = 0.000000635 V, v_off_fin = -0.000002176 V 15:28:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141475576 Vs 15:28:57   Voltage Measurement, V = 0.000000 V 15:28:57 Temperature Measurement, Probe Number = 0, T = 21.436000 C 15:28:58 Temperature Measurement, Probe Number = 1, T = 22.399000 C 15:28:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.44 P2 = 3458_Meas_Junction, Value = 22.40 15:28:58 Integrated Voltage Measurement... 15:29:29 Voltage Offset Correction: v_off_ini = -0.000000722 V, v_off_fin = 0.000000231 V 15:29:29 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.141499606 Vs 15:29:29 Integrated Voltage Measurement... 15:30:00 Voltage Offset Correction: v_off_ini = 0.000000869 V, v_off_fin = -0.000001191 V 15:30:00 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141477330 Vs 15:30:01   Voltage Measurement, V = 0.000000 V 15:30:01 Temperature Measurement, Probe Number = 0, T = 21.437000 C 15:30:02 Temperature Measurement, Probe Number = 1, T = 22.425000 C 15:30:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.44 P2 = 3458_Meas_Junction, Value = 22.43 15:30:02 Integrated Voltage Measurement... 15:30:33 Voltage Offset Correction: v_off_ini = -0.000000293 V, v_off_fin = 0.000001652 V 15:30:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.141468147 Vs 15:30:33 Integrated Voltage Measurement... 15:31:06 Voltage Offset Correction: v_off_ini = 0.000000599 V, v_off_fin = -0.000001628 V 15:31:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141476041 Vs 15:31:07   Voltage Measurement, V = 0.000000 V 15:31:08 Temperature Measurement, Probe Number = 0, T = 21.427000 C 15:31:08 Temperature Measurement, Probe Number = 1, T = 22.425000 C 15:31:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 22.43 15:31:08 Integrated Voltage Measurement... 15:31:44 Voltage Offset Correction: v_off_ini = -0.000000528 V, v_off_fin = 0.000000595 V 15:31:44 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141483580 Vs 15:31:44 Integrated Voltage Measurement... 15:32:15 Voltage Offset Correction: v_off_ini = 0.000000638 V, v_off_fin = -0.000001272 V 15:32:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.141474246 Vs 15:32:16   Voltage Measurement, V = 0.000000 V 15:32:17 Temperature Measurement, Probe Number = 0, T = 21.431000 C 15:32:18 Temperature Measurement, Probe Number = 1, T = 22.438000 C 15:32:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.43 P2 = 3458_Meas_Junction, Value = 22.44 15:32:18 Integrated Voltage Measurement... 15:32:49 Voltage Offset Correction: v_off_ini = -0.000000736 V, v_off_fin = 0.000000644 V 15:32:49 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.141490730 Vs 15:32:49 Integrated Voltage Measurement... 15:33:20 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000001507 V 15:33:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141476220 Vs 15:33:21   Voltage Measurement, V = 0.000000 V 15:33:21 Temperature Measurement, Probe Number = 0, T = 21.437000 C 15:33:22 Temperature Measurement, Probe Number = 1, T = 22.424000 C 15:33:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.44 P2 = 3458_Meas_Junction, Value = 22.42 15:33:22 Integrated Voltage Measurement... 15:33:53 Voltage Offset Correction: v_off_ini = -0.000000792 V, v_off_fin = 0.000002155 V 15:33:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.141503130 Vs 15:33:53 Integrated Voltage Measurement... 15:34:26 Voltage Offset Correction: v_off_ini = 0.000000609 V, v_off_fin = -0.000001445 V 15:34:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141469860 Vs 15:34:27   Voltage Measurement, V = 0.000000 V 15:34:28 Temperature Measurement, Probe Number = 0, T = 21.446000 C 15:34:28 Temperature Measurement, Probe Number = 1, T = 22.401000 C 15:34:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.40 15:34:29 Integrated Voltage Measurement... 15:35:00 Voltage Offset Correction: v_off_ini = -0.000000934 V, v_off_fin = 0.000000530 V 15:35:00 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141498112 Vs 15:35:00 Integrated Voltage Measurement... 15:35:31 Voltage Offset Correction: v_off_ini = 0.000000971 V, v_off_fin = -0.000000987 V 15:35:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.141470214 Vs 15:35:32   Voltage Measurement, V = 0.000000 V 15:35:33 Temperature Measurement, Probe Number = 0, T = 21.458000 C 15:35:34 Temperature Measurement, Probe Number = 1, T = 22.414000 C 15:35:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.46 P2 = 3458_Meas_Junction, Value = 22.41 15:35:34 Integrated Voltage Measurement... 15:36:05 Voltage Offset Correction: v_off_ini = -0.000000596 V, v_off_fin = 0.000000813 V 15:36:05 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.141485492 Vs 15:36:05 Integrated Voltage Measurement... 15:36:36 Voltage Offset Correction: v_off_ini = 0.000000684 V, v_off_fin = -0.000001635 V 15:36:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141467252 Vs 15:36:37   Voltage Measurement, V = 0.000000 V 15:36:38 Temperature Measurement, Probe Number = 0, T = 21.457000 C 15:36:38 Temperature Measurement, Probe Number = 1, T = 22.377000 C 15:36:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.46 P2 = 3458_Meas_Junction, Value = 22.38 15:36:38 Integrated Voltage Measurement... 15:37:09 Voltage Offset Correction: v_off_ini = -0.000000581 V, v_off_fin = 0.000000650 V 15:37:09 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.141485325 Vs 15:37:09 Integrated Voltage Measurement... 15:37:41 Voltage Offset Correction: v_off_ini = 0.000000843 V, v_off_fin = 0.000000059 V 15:37:41 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.141480720 Vs 15:37:42   Voltage Measurement, V = 0.000000 V 15:37:42 Temperature Measurement, Probe Number = 0, T = 21.451000 C 15:37:43 Temperature Measurement, Probe Number = 1, T = 22.401000 C 15:37:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 21.45 P2 = 3458_Meas_Junction, Value = 22.40 15:37:43 Integrated Voltage Measurement... 15:38:16 Voltage Offset Correction: v_off_ini = -0.000000553 V, v_off_fin = 0.000000681 V 15:38:16 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.141494231 Vs 15:38:16 Integrated Voltage Measurement... 15:38:47 Voltage Offset Correction: v_off_ini = 0.000000879 V, v_off_fin = -0.000001342 V 15:38:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.141469704 Vs