SLAC Magnetic Measurements Date: 01-21-2021 Time: 08:48:08 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_001_Cell_28_Upstairs Serial Number: PC33408 Run Number: 9 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement upstairs, cable through switch Full Set 9 08:48:26 Ambient Measurement Device(s) Being Used, type = None 08:48:26 Magnet Voltage Measurement Device(s) Being Used, type = None 08:48:26 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 08:48:26 XMAG Device(s) Being Used, type = None 08:48:26 Ambient Measurement Device(s) Being Used, type = None 08:48:55   Voltage Measurement, V = 0.000000 V 08:48:56 Temperature Measurement, Probe Number = 0, T = 23.511000 C 08:48:56 Temperature Measurement, Probe Number = 1, T = 24.161000 C 08:48:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.51 P2 = 3458_Meas_Junction, Value = 24.16 08:48:56 Integrated Voltage Measurement... 08:49:44 Voltage Offset Correction: v_off_ini = 0.000009897 V, v_off_fin = 0.000013414 V 08:49:44 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.142799591 Vs 08:49:44 Integrated Voltage Measurement... 08:50:22 Voltage Offset Correction: v_off_ini = 0.000011723 V, v_off_fin = 0.000010418 V 08:50:22 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142783456 Vs 08:50:23   Voltage Measurement, V = 0.000000 V 08:50:23 Temperature Measurement, Probe Number = 0, T = 23.494000 C 08:50:24 Temperature Measurement, Probe Number = 1, T = 24.158000 C 08:50:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.16 08:50:24 Integrated Voltage Measurement... 08:50:54 Voltage Offset Correction: v_off_ini = 0.000011987 V, v_off_fin = 0.000012932 V 08:50:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142789175 Vs 08:50:54 Integrated Voltage Measurement... 08:51:26 Voltage Offset Correction: v_off_ini = 0.000011954 V, v_off_fin = 0.000011576 V 08:51:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142780170 Vs 08:51:27   Voltage Measurement, V = 0.000000 V 08:51:27 Temperature Measurement, Probe Number = 0, T = 23.493000 C 08:51:28 Temperature Measurement, Probe Number = 1, T = 24.149000 C 08:51:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.15 08:51:28 Integrated Voltage Measurement... 08:51:59 Voltage Offset Correction: v_off_ini = 0.000010742 V, v_off_fin = 0.000012303 V 08:51:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142787458 Vs 08:51:59 Integrated Voltage Measurement... 08:52:30 Voltage Offset Correction: v_off_ini = 0.000012276 V, v_off_fin = 0.000011176 V 08:52:30 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142798616 Vs 08:52:31   Voltage Measurement, V = 0.000000 V 08:52:32 Temperature Measurement, Probe Number = 0, T = 23.487000 C 08:52:32 Temperature Measurement, Probe Number = 1, T = 24.143000 C 08:52:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.14 08:52:32 Integrated Voltage Measurement... 08:53:03 Voltage Offset Correction: v_off_ini = 0.000011451 V, v_off_fin = 0.000012134 V 08:53:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142796621 Vs 08:53:03 Integrated Voltage Measurement... 08:53:36 Voltage Offset Correction: v_off_ini = 0.000012152 V, v_off_fin = 0.000010344 V 08:53:36 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142786650 Vs 08:53:37   Voltage Measurement, V = 0.000000 V 08:53:38 Temperature Measurement, Probe Number = 0, T = 23.490000 C 08:53:39 Temperature Measurement, Probe Number = 1, T = 24.154000 C 08:53:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.49 P2 = 3458_Meas_Junction, Value = 24.15 08:53:39 Integrated Voltage Measurement... 08:54:12 Voltage Offset Correction: v_off_ini = 0.000011022 V, v_off_fin = 0.000011144 V 08:54:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142789607 Vs 08:54:12 Integrated Voltage Measurement... 08:54:50 Voltage Offset Correction: v_off_ini = 0.000012245 V, v_off_fin = 0.000011026 V 08:54:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142778429 Vs 08:54:51   Voltage Measurement, V = 0.000000 V 08:54:52 Temperature Measurement, Probe Number = 0, T = 23.513000 C 08:54:52 Temperature Measurement, Probe Number = 1, T = 24.166000 C 08:54:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.51 P2 = 3458_Meas_Junction, Value = 24.17 08:54:52 Integrated Voltage Measurement... 08:55:23 Voltage Offset Correction: v_off_ini = 0.000011435 V, v_off_fin = 0.000012755 V 08:55:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142784737 Vs 08:55:23 Integrated Voltage Measurement... 08:55:56 Voltage Offset Correction: v_off_ini = 0.000011995 V, v_off_fin = 0.000011226 V 08:55:56 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142791545 Vs 08:55:57   Voltage Measurement, V = 0.000000 V 08:55:58 Temperature Measurement, Probe Number = 0, T = 23.509000 C 08:55:58 Temperature Measurement, Probe Number = 1, T = 24.164000 C 08:55:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.51 P2 = 3458_Meas_Junction, Value = 24.16 08:55:58 Integrated Voltage Measurement... 08:56:30 Voltage Offset Correction: v_off_ini = 0.000011697 V, v_off_fin = 0.000011890 V 08:56:30 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142788206 Vs 08:56:30 Integrated Voltage Measurement... 08:57:01 Voltage Offset Correction: v_off_ini = 0.000012025 V, v_off_fin = 0.000011044 V 08:57:01 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142780874 Vs 08:57:02   Voltage Measurement, V = 0.000000 V 08:57:03 Temperature Measurement, Probe Number = 0, T = 23.510000 C 08:57:03 Temperature Measurement, Probe Number = 1, T = 24.186000 C 08:57:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.51 P2 = 3458_Meas_Junction, Value = 24.19 08:57:03 Integrated Voltage Measurement... 08:57:34 Voltage Offset Correction: v_off_ini = 0.000011490 V, v_off_fin = 0.000012264 V 08:57:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142793148 Vs 08:57:34 Integrated Voltage Measurement... 08:58:04 Voltage Offset Correction: v_off_ini = 0.000011991 V, v_off_fin = 0.000010825 V 08:58:04 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142782455 Vs 08:58:05   Voltage Measurement, V = 0.000000 V 08:58:06 Temperature Measurement, Probe Number = 0, T = 23.528000 C 08:58:07 Temperature Measurement, Probe Number = 1, T = 24.197000 C 08:58:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.53 P2 = 3458_Meas_Junction, Value = 24.20 08:58:07 Integrated Voltage Measurement... 08:58:39 Voltage Offset Correction: v_off_ini = 0.000011877 V, v_off_fin = 0.000013255 V 08:58:39 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142801740 Vs 08:58:39 Integrated Voltage Measurement... 08:59:10 Voltage Offset Correction: v_off_ini = 0.000011883 V, v_off_fin = 0.000010867 V 08:59:10 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142772154 Vs 08:59:11   Voltage Measurement, V = 0.000000 V 08:59:12 Temperature Measurement, Probe Number = 0, T = 23.512000 C 08:59:13 Temperature Measurement, Probe Number = 1, T = 24.188000 C 08:59:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 23.51 P2 = 3458_Meas_Junction, Value = 24.19 08:59:13 Integrated Voltage Measurement... 08:59:44 Voltage Offset Correction: v_off_ini = 0.000011459 V, v_off_fin = 0.000012251 V 08:59:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142780411 Vs 08:59:44 Integrated Voltage Measurement... 09:00:14 Voltage Offset Correction: v_off_ini = 0.000012578 V, v_off_fin = 0.000011340 V 09:00:14 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142781460 Vs