SLAC Magnetic Measurements Date: 10-06-2020 Time: 13:00:25 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU_001_Cell_28 Serial Number: PC33408 Run Number: 10 Measurement Device: Coil Operator: sda Comment: Coil Integral measurement in tunnel. Full Set 10 13:00:28 Ambient Measurement Device(s) Being Used, type = None 13:00:28 Magnet Voltage Measurement Device(s) Being Used, type = None 13:00:28 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:00:28 XMAG Device(s) Being Used, type = None 13:00:28 Ambient Measurement Device(s) Being Used, type = None 13:00:38   Voltage Measurement, V = 0.000000 V 13:00:39 Temperature Measurement, Probe Number = 0, T = 20.755000 C 13:00:39 Temperature Measurement, Probe Number = 1, T = 21.551000 C 13:00:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.75 P2 = 3458_Meas_Junction, Value = 21.55 13:00:39 Integrated Voltage Measurement... 13:01:08 Voltage Offset Correction: v_off_ini = -0.000000255 V, v_off_fin = 0.000000155 V 13:01:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142867789 Vs 13:01:08 Integrated Voltage Measurement... 13:01:42 Voltage Offset Correction: v_off_ini = -0.000000087 V, v_off_fin = -0.000001438 V 13:01:42 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142882338 Vs 13:01:43   Voltage Measurement, V = 0.000000 V 13:01:43 Temperature Measurement, Probe Number = 0, T = 20.759000 C 13:01:44 Temperature Measurement, Probe Number = 1, T = 21.553000 C 13:01:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.76 P2 = 3458_Meas_Junction, Value = 21.55 13:01:44 Integrated Voltage Measurement... 13:02:20 Voltage Offset Correction: v_off_ini = -0.000000541 V, v_off_fin = 0.000000324 V 13:02:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142877628 Vs 13:02:20 Integrated Voltage Measurement... 13:02:57 Voltage Offset Correction: v_off_ini = -0.000000086 V, v_off_fin = -0.000001969 V 13:02:57 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.142871758 Vs 13:02:58   Voltage Measurement, V = 0.000000 V 13:02:59 Temperature Measurement, Probe Number = 0, T = 20.803000 C 13:02:59 Temperature Measurement, Probe Number = 1, T = 21.549000 C 13:02:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.55 13:02:59 Integrated Voltage Measurement... 13:03:36 Voltage Offset Correction: v_off_ini = -0.000000669 V, v_off_fin = -0.000000140 V 13:03:36 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142878863 Vs 13:03:36 Integrated Voltage Measurement... 13:04:09 Voltage Offset Correction: v_off_ini = -0.000000096 V, v_off_fin = -0.000001156 V 13:04:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142868704 Vs 13:04:10   Voltage Measurement, V = 0.000000 V 13:04:11 Temperature Measurement, Probe Number = 0, T = 20.803000 C 13:04:12 Temperature Measurement, Probe Number = 1, T = 21.549000 C 13:04:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.80 P2 = 3458_Meas_Junction, Value = 21.55 13:04:12 Integrated Voltage Measurement... 13:04:46 Voltage Offset Correction: v_off_ini = -0.000000423 V, v_off_fin = 0.000000752 V 13:04:46 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.142873620 Vs 13:04:46 Integrated Voltage Measurement... 13:05:19 Voltage Offset Correction: v_off_ini = -0.000000098 V, v_off_fin = -0.000000790 V 13:05:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142872468 Vs 13:05:20   Voltage Measurement, V = 0.000000 V 13:05:21 Temperature Measurement, Probe Number = 0, T = 20.824000 C 13:05:21 Temperature Measurement, Probe Number = 1, T = 21.547000 C 13:05:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 21.55 13:05:21 Integrated Voltage Measurement... 13:05:56 Voltage Offset Correction: v_off_ini = -0.000000604 V, v_off_fin = 0.000000166 V 13:05:56 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.142877235 Vs 13:05:56 Integrated Voltage Measurement... 13:06:28 Voltage Offset Correction: v_off_ini = -0.000000075 V, v_off_fin = -0.000001026 V 13:06:28 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142860911 Vs 13:06:29   Voltage Measurement, V = 0.000000 V 13:06:30 Temperature Measurement, Probe Number = 0, T = 20.826000 C 13:06:30 Temperature Measurement, Probe Number = 1, T = 21.546000 C 13:06:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.83 P2 = 3458_Meas_Junction, Value = 21.55 13:06:30 Integrated Voltage Measurement... 13:07:03 Voltage Offset Correction: v_off_ini = -0.000000546 V, v_off_fin = -0.000000612 V 13:07:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142879828 Vs 13:07:03 Integrated Voltage Measurement... 13:07:34 Voltage Offset Correction: v_off_ini = -0.000000314 V, v_off_fin = -0.000001607 V 13:07:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142868114 Vs 13:07:35   Voltage Measurement, V = 0.000000 V 13:07:35 Temperature Measurement, Probe Number = 0, T = 20.827000 C 13:07:36 Temperature Measurement, Probe Number = 1, T = 21.540000 C 13:07:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.83 P2 = 3458_Meas_Junction, Value = 21.54 13:07:36 Integrated Voltage Measurement... 13:08:10 Voltage Offset Correction: v_off_ini = -0.000000948 V, v_off_fin = -0.000000535 V 13:08:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142875727 Vs 13:08:10 Integrated Voltage Measurement... 13:08:41 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = -0.000000741 V 13:08:41 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.142866852 Vs 13:08:42   Voltage Measurement, V = 0.000000 V 13:08:43 Temperature Measurement, Probe Number = 0, T = 20.821000 C 13:08:43 Temperature Measurement, Probe Number = 1, T = 21.540000 C 13:08:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.82 P2 = 3458_Meas_Junction, Value = 21.54 13:08:43 Integrated Voltage Measurement... 13:09:23 Voltage Offset Correction: v_off_ini = -0.000000440 V, v_off_fin = -0.000000200 V 13:09:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142874392 Vs 13:09:23 Integrated Voltage Measurement... 13:09:54 Voltage Offset Correction: v_off_ini = -0.000000445 V, v_off_fin = -0.000000396 V 13:09:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142861988 Vs 13:09:55   Voltage Measurement, V = 0.000000 V 13:09:56 Temperature Measurement, Probe Number = 0, T = 20.854000 C 13:09:56 Temperature Measurement, Probe Number = 1, T = 21.538000 C 13:09:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.85 P2 = 3458_Meas_Junction, Value = 21.54 13:09:56 Integrated Voltage Measurement... 13:10:29 Voltage Offset Correction: v_off_ini = -0.000000540 V, v_off_fin = -0.000000299 V 13:10:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142876130 Vs 13:10:29 Integrated Voltage Measurement... 13:11:03 Voltage Offset Correction: v_off_ini = 0.000000259 V, v_off_fin = -0.000000557 V 13:11:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142867771 Vs 13:11:04   Voltage Measurement, V = 0.000000 V 13:11:05 Temperature Measurement, Probe Number = 0, T = 20.873000 C 13:11:06 Temperature Measurement, Probe Number = 1, T = 21.545000 C 13:11:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Walker_Meas_Junction, Value = 20.87 P2 = 3458_Meas_Junction, Value = 21.55 13:11:06 Integrated Voltage Measurement... 13:11:40 Voltage Offset Correction: v_off_ini = -0.000000587 V, v_off_fin = -0.000000256 V 13:11:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.142875368 Vs 13:11:40 Integrated Voltage Measurement... 13:12:14 Voltage Offset Correction: v_off_ini = -0.000000267 V, v_off_fin = -0.000000807 V 13:12:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.142858889 Vs