SLAC Magnetic Measurements Date: 09-14-2019 Time: 11:31:18 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU3_TCRM_Tension_27 Serial Number: SXU3 Run Number: 17 Measurement Device: Flex_Coil Operator: sda Comment: BNC cable dis and reconnected at 3458A as if measuring in the tunnel. 8 days later 11:31:20 Ambient Measurement Device(s) Being Used, type = None 11:31:20 Magnet Voltage Measurement Device(s) Being Used, type = None 11:31:21 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:31:21 XMAG Device(s) Being Used, type = None 11:31:21 Ambient Measurement Device(s) Being Used, type = None 11:31:31 Temperature Measurement, Probe Number = 0, T = 20.349000 C 11:31:31 Temperature Measurement, Probe Number = 1, T = 19.860000 C 11:31:32 Temperature Measurement, Probe Number = 2, T = 19.890000 C 11:31:33 Temperature Measurement, Probe Number = 3, T = 19.849000 C 11:31:33 Temperature Measurement, Probe Number = 4, T = 19.860000 C 11:31:34 Temperature Measurement, Probe Number = 5, T = 19.811000 C 11:31:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:31:34 Integrated Voltage Measurement... 11:31:56 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = -0.000003395 V 11:31:56 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = -0.142431289 Vs 11:31:56 Integrated Voltage Measurement... 11:32:19 Voltage Offset Correction: v_off_ini = 0.000003629 V, v_off_fin = 0.000000439 V 11:32:20 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.142443640 Vs 11:32:33 Temperature Measurement, Probe Number = 0, T = 20.365000 C 11:32:34 Temperature Measurement, Probe Number = 1, T = 19.858000 C 11:32:34 Temperature Measurement, Probe Number = 2, T = 19.886000 C 11:32:35 Temperature Measurement, Probe Number = 3, T = 19.844000 C 11:32:36 Temperature Measurement, Probe Number = 4, T = 19.857000 C 11:32:36 Temperature Measurement, Probe Number = 5, T = 19.807000 C 11:32:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.36 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:32:36 Integrated Voltage Measurement... 11:32:58 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = -0.000002979 V 11:32:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142489681 Vs 11:32:58 Integrated Voltage Measurement... 11:33:20 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = 0.000001237 V 11:33:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142491774 Vs 11:33:34 Temperature Measurement, Probe Number = 0, T = 20.386000 C 11:33:35 Temperature Measurement, Probe Number = 1, T = 19.859000 C 11:33:35 Temperature Measurement, Probe Number = 2, T = 19.886000 C 11:33:36 Temperature Measurement, Probe Number = 3, T = 19.844000 C 11:33:36 Temperature Measurement, Probe Number = 4, T = 19.858000 C 11:33:37 Temperature Measurement, Probe Number = 5, T = 19.807000 C 11:33:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.39 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:33:37 Integrated Voltage Measurement... 11:33:59 Voltage Offset Correction: v_off_ini = -0.000001017 V, v_off_fin = -0.000003198 V 11:33:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142493506 Vs 11:33:59 Integrated Voltage Measurement... 11:34:21 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000002020 V 11:34:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142523290 Vs 11:34:35 Temperature Measurement, Probe Number = 0, T = 20.359000 C 11:34:36 Temperature Measurement, Probe Number = 1, T = 19.859000 C 11:34:36 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:34:37 Temperature Measurement, Probe Number = 3, T = 19.842000 C 11:34:37 Temperature Measurement, Probe Number = 4, T = 19.858000 C 11:34:38 Temperature Measurement, Probe Number = 5, T = 19.807000 C 11:34:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.36 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:34:38 Integrated Voltage Measurement... 11:35:00 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000001698 V 11:35:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142497246 Vs 11:35:00 Integrated Voltage Measurement... 11:35:22 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000000673 V 11:35:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142508916 Vs 11:35:36 Temperature Measurement, Probe Number = 0, T = 20.320000 C 11:35:37 Temperature Measurement, Probe Number = 1, T = 19.855000 C 11:35:37 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:35:38 Temperature Measurement, Probe Number = 3, T = 19.841000 C 11:35:38 Temperature Measurement, Probe Number = 4, T = 19.857000 C 11:35:39 Temperature Measurement, Probe Number = 5, T = 19.806000 C 11:35:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:35:39 Integrated Voltage Measurement... 11:36:01 Voltage Offset Correction: v_off_ini = -0.000000029 V, v_off_fin = -0.000001559 V 11:36:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142505963 Vs 11:36:01 Integrated Voltage Measurement... 11:36:23 Voltage Offset Correction: v_off_ini = 0.000000007 V, v_off_fin = 0.000001054 V 11:36:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142497922 Vs 11:36:37 Temperature Measurement, Probe Number = 0, T = 20.349000 C 11:36:38 Temperature Measurement, Probe Number = 1, T = 19.858000 C 11:36:38 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:36:39 Temperature Measurement, Probe Number = 3, T = 19.841000 C 11:36:39 Temperature Measurement, Probe Number = 4, T = 19.858000 C 11:36:40 Temperature Measurement, Probe Number = 5, T = 19.808000 C 11:36:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:36:40 Integrated Voltage Measurement... 11:37:02 Voltage Offset Correction: v_off_ini = 0.000001113 V, v_off_fin = -0.000000937 V 11:37:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142520122 Vs 11:37:02 Integrated Voltage Measurement... 11:37:24 Voltage Offset Correction: v_off_ini = -0.000002312 V, v_off_fin = -0.000001149 V 11:37:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142493562 Vs 11:37:38 Temperature Measurement, Probe Number = 0, T = 20.325000 C 11:37:39 Temperature Measurement, Probe Number = 1, T = 19.858000 C 11:37:39 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:37:40 Temperature Measurement, Probe Number = 3, T = 19.841000 C 11:37:40 Temperature Measurement, Probe Number = 4, T = 19.859000 C 11:37:41 Temperature Measurement, Probe Number = 5, T = 19.808000 C 11:37:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:37:41 Integrated Voltage Measurement... 11:38:03 Voltage Offset Correction: v_off_ini = 0.000000644 V, v_off_fin = -0.000000571 V 11:38:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142526613 Vs 11:38:03 Integrated Voltage Measurement... 11:38:25 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = -0.000002064 V 11:38:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142498403 Vs 11:38:39 Temperature Measurement, Probe Number = 0, T = 20.259000 C 11:38:40 Temperature Measurement, Probe Number = 1, T = 19.860000 C 11:38:40 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:38:41 Temperature Measurement, Probe Number = 3, T = 19.837000 C 11:38:41 Temperature Measurement, Probe Number = 4, T = 19.859000 C 11:38:42 Temperature Measurement, Probe Number = 5, T = 19.808000 C 11:38:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:38:42 Integrated Voltage Measurement... 11:39:04 Voltage Offset Correction: v_off_ini = 0.000001727 V, v_off_fin = -0.000000388 V 11:39:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142544783 Vs 11:39:04 Integrated Voltage Measurement... 11:39:26 Voltage Offset Correction: v_off_ini = -0.000002649 V, v_off_fin = -0.000000585 V 11:39:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142500520 Vs 11:39:40 Temperature Measurement, Probe Number = 0, T = 20.300000 C 11:39:41 Temperature Measurement, Probe Number = 1, T = 19.858000 C 11:39:41 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:39:42 Temperature Measurement, Probe Number = 3, T = 19.839000 C 11:39:42 Temperature Measurement, Probe Number = 4, T = 19.857000 C 11:39:43 Temperature Measurement, Probe Number = 5, T = 19.806000 C 11:39:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.81 11:39:43 Integrated Voltage Measurement... 11:40:05 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000002429 V 11:40:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142512404 Vs 11:40:05 Integrated Voltage Measurement... 11:40:27 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = 0.000000117 V 11:40:27 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = 0.142492569 Vs 11:40:41 Temperature Measurement, Probe Number = 0, T = 20.268000 C 11:40:42 Temperature Measurement, Probe Number = 1, T = 19.856000 C 11:40:42 Temperature Measurement, Probe Number = 2, T = 19.885000 C 11:40:43 Temperature Measurement, Probe Number = 3, T = 19.839000 C 11:40:43 Temperature Measurement, Probe Number = 4, T = 19.854000 C 11:40:44 Temperature Measurement, Probe Number = 5, T = 19.806000 C 11:40:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.81 11:40:44 Integrated Voltage Measurement... 11:41:06 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = -0.000003526 V 11:41:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142484995 Vs 11:41:06 Integrated Voltage Measurement... 11:41:28 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = 0.000001434 V 11:41:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142468891 Vs