SLAC Magnetic Measurements Date: 09-13-2019 Time: 08:26:42 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU3_TCRM_Tension_27 Serial Number: SXU3 Run Number: 14 Measurement Device: Flex_Coil Operator: sda Comment: BNC cable dis and reconnected at 3458A as if measuring in the tunnel. 7 days later 08:26:44 Ambient Measurement Device(s) Being Used, type = None 08:26:44 Magnet Voltage Measurement Device(s) Being Used, type = None 08:26:45 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 08:26:45 XMAG Device(s) Being Used, type = None 08:26:45 Ambient Measurement Device(s) Being Used, type = None 08:26:53 Temperature Measurement, Probe Number = 0, T = 20.132000 C 08:26:54 Temperature Measurement, Probe Number = 1, T = 19.817000 C 08:26:55 Temperature Measurement, Probe Number = 2, T = 19.825000 C 08:26:55 Temperature Measurement, Probe Number = 3, T = 19.801000 C 08:26:56 Temperature Measurement, Probe Number = 4, T = 19.802000 C 08:26:57 Temperature Measurement, Probe Number = 5, T = 19.775000 C 08:26:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.82 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:26:57 Integrated Voltage Measurement... 08:27:19 Voltage Offset Correction: v_off_ini = 0.000000498 V, v_off_fin = 0.000000410 V 08:27:19 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = -0.142473642 Vs 08:27:19 Integrated Voltage Measurement... 08:27:42 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000000754 V 08:27:42 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.142447055 Vs 08:27:55 Temperature Measurement, Probe Number = 0, T = 20.149000 C 08:27:56 Temperature Measurement, Probe Number = 1, T = 19.817000 C 08:27:57 Temperature Measurement, Probe Number = 2, T = 19.825000 C 08:27:57 Temperature Measurement, Probe Number = 3, T = 19.796000 C 08:27:58 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:27:58 Temperature Measurement, Probe Number = 5, T = 19.771000 C 08:27:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.82 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:27:58 Integrated Voltage Measurement... 08:28:21 Voltage Offset Correction: v_off_ini = -0.000000161 V, v_off_fin = -0.000006462 V 08:28:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142428465 Vs 08:28:21 Integrated Voltage Measurement... 08:28:43 Voltage Offset Correction: v_off_ini = -0.000000834 V, v_off_fin = -0.000000293 V 08:28:43 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.142453427 Vs 08:28:57 Temperature Measurement, Probe Number = 0, T = 20.149000 C 08:28:58 Temperature Measurement, Probe Number = 1, T = 19.817000 C 08:28:58 Temperature Measurement, Probe Number = 2, T = 19.825000 C 08:28:59 Temperature Measurement, Probe Number = 3, T = 19.793000 C 08:28:59 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:29:00 Temperature Measurement, Probe Number = 5, T = 19.771000 C 08:29:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.82 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:29:00 Integrated Voltage Measurement... 08:29:22 Voltage Offset Correction: v_off_ini = 0.000000805 V, v_off_fin = -0.000001434 V 08:29:22 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142484038 Vs 08:29:22 Integrated Voltage Measurement... 08:29:44 Voltage Offset Correction: v_off_ini = -0.000001046 V, v_off_fin = 0.000002845 V 08:29:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142435582 Vs 08:29:58 Temperature Measurement, Probe Number = 0, T = 20.168000 C 08:29:59 Temperature Measurement, Probe Number = 1, T = 19.818000 C 08:29:59 Temperature Measurement, Probe Number = 2, T = 19.828000 C 08:30:00 Temperature Measurement, Probe Number = 3, T = 19.792000 C 08:30:00 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:30:01 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:30:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:30:01 Integrated Voltage Measurement... 08:30:23 Voltage Offset Correction: v_off_ini = -0.000001566 V, v_off_fin = -0.000002019 V 08:30:23 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142459992 Vs 08:30:23 Integrated Voltage Measurement... 08:30:46 Voltage Offset Correction: v_off_ini = -0.000003380 V, v_off_fin = 0.000000790 V 08:30:46 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.142477858 Vs 08:31:00 Temperature Measurement, Probe Number = 0, T = 20.158000 C 08:31:00 Temperature Measurement, Probe Number = 1, T = 19.819000 C 08:31:01 Temperature Measurement, Probe Number = 2, T = 19.830000 C 08:31:01 Temperature Measurement, Probe Number = 3, T = 19.799000 C 08:31:02 Temperature Measurement, Probe Number = 4, T = 19.801000 C 08:31:03 Temperature Measurement, Probe Number = 5, T = 19.774000 C 08:31:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:31:03 Integrated Voltage Measurement... 08:31:25 Voltage Offset Correction: v_off_ini = 0.000000388 V, v_off_fin = -0.000000849 V 08:31:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142479174 Vs 08:31:25 Integrated Voltage Measurement... 08:31:47 Voltage Offset Correction: v_off_ini = -0.000000417 V, v_off_fin = 0.000001434 V 08:31:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142425361 Vs 08:32:01 Temperature Measurement, Probe Number = 0, T = 20.087000 C 08:32:02 Temperature Measurement, Probe Number = 1, T = 19.815000 C 08:32:02 Temperature Measurement, Probe Number = 2, T = 19.823000 C 08:32:03 Temperature Measurement, Probe Number = 3, T = 19.800000 C 08:32:03 Temperature Measurement, Probe Number = 4, T = 19.799000 C 08:32:04 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:32:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.82 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:32:04 Integrated Voltage Measurement... 08:32:26 Voltage Offset Correction: v_off_ini = -0.000000476 V, v_off_fin = -0.000000454 V 08:32:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142475647 Vs 08:32:26 Integrated Voltage Measurement... 08:32:48 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000000066 V 08:32:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142444919 Vs 08:33:02 Temperature Measurement, Probe Number = 0, T = 20.053000 C 08:33:02 Temperature Measurement, Probe Number = 1, T = 19.815000 C 08:33:03 Temperature Measurement, Probe Number = 2, T = 19.826000 C 08:33:04 Temperature Measurement, Probe Number = 3, T = 19.801000 C 08:33:04 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:33:05 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:33:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:33:05 Integrated Voltage Measurement... 08:33:27 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = 0.000000088 V 08:33:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142478837 Vs 08:33:27 Integrated Voltage Measurement... 08:33:49 Voltage Offset Correction: v_off_ini = 0.000000022 V, v_off_fin = 0.000001720 V 08:33:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142430304 Vs 08:34:03 Temperature Measurement, Probe Number = 0, T = 20.013000 C 08:34:03 Temperature Measurement, Probe Number = 1, T = 19.816000 C 08:34:04 Temperature Measurement, Probe Number = 2, T = 19.827000 C 08:34:05 Temperature Measurement, Probe Number = 3, T = 19.804000 C 08:34:05 Temperature Measurement, Probe Number = 4, T = 19.799000 C 08:34:06 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:34:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:34:06 Integrated Voltage Measurement... 08:34:28 Voltage Offset Correction: v_off_ini = 0.000000380 V, v_off_fin = -0.000001807 V 08:34:28 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = -0.142479643 Vs 08:34:28 Integrated Voltage Measurement... 08:34:50 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000000080 V 08:34:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142453328 Vs 08:35:04 Temperature Measurement, Probe Number = 0, T = 20.075000 C 08:35:04 Temperature Measurement, Probe Number = 1, T = 19.817000 C 08:35:05 Temperature Measurement, Probe Number = 2, T = 19.829000 C 08:35:06 Temperature Measurement, Probe Number = 3, T = 19.805000 C 08:35:06 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:35:07 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:35:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:35:07 Integrated Voltage Measurement... 08:35:29 Voltage Offset Correction: v_off_ini = -0.000002633 V, v_off_fin = 0.000000380 V 08:35:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.142465536 Vs 08:35:29 Integrated Voltage Measurement... 08:35:52 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000000234 V 08:35:52 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.142445298 Vs 08:36:05 Temperature Measurement, Probe Number = 0, T = 20.128000 C 08:36:06 Temperature Measurement, Probe Number = 1, T = 19.815000 C 08:36:06 Temperature Measurement, Probe Number = 2, T = 19.826000 C 08:36:07 Temperature Measurement, Probe Number = 3, T = 19.808000 C 08:36:08 Temperature Measurement, Probe Number = 4, T = 19.800000 C 08:36:08 Temperature Measurement, Probe Number = 5, T = 19.772000 C 08:36:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.77 08:36:08 Integrated Voltage Measurement... 08:36:30 Voltage Offset Correction: v_off_ini = 0.000000585 V, v_off_fin = 0.000001039 V 08:36:30 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.142472236 Vs 08:36:30 Integrated Voltage Measurement... 08:36:53 Voltage Offset Correction: v_off_ini = -0.000000095 V, v_off_fin = 0.000001229 V 08:36:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.142435321 Vs