SLAC Magnetic Measurements Date: 06-13-2019 Time: 09:54:33 Project: LCLS-II Magnet Type: Radiation_Detection_System Magnet Name: SXU3_TCRM_Tension Serial Number: SXU3 Run Number: 10 Measurement Device: Flex_Coil Operator: sda Comment: Long term test. Gap from 8 to 12 mm every hour 09:54:36 Ambient Measurement Device(s) Being Used, type = None 09:54:36 Magnet Voltage Measurement Device(s) Being Used, type = None 09:54:36 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:54:36 XMAG Device(s) Being Used, type = None 09:54:36 Ambient Measurement Device(s) Being Used, type = None 09:54:46 Temperature Measurement, Probe Number = 0, T = 20.041000 C 09:54:47 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:54:48 Temperature Measurement, Probe Number = 2, T = 20.072000 C 09:54:48 Temperature Measurement, Probe Number = 3, T = 19.999000 C 09:54:49 Temperature Measurement, Probe Number = 4, T = 20.048000 C 09:54:50 Temperature Measurement, Probe Number = 5, T = 19.997000 C 09:54:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 09:54:50 Integrated Voltage Measurement... 09:55:12 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = 0.000000190 V 09:55:12 Integrated Voltage Measurement Delta Gap = 0.0040000 m VT = 0.158486453 Vs 09:55:12 Integrated Voltage Measurement... 09:55:35 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000003109 V 09:55:35 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158516137 Vs 09:55:48 Temperature Measurement, Probe Number = 0, T = 20.034000 C 09:55:49 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:55:49 Temperature Measurement, Probe Number = 2, T = 20.069000 C 09:55:50 Temperature Measurement, Probe Number = 3, T = 19.999000 C 09:55:51 Temperature Measurement, Probe Number = 4, T = 20.045000 C 09:55:51 Temperature Measurement, Probe Number = 5, T = 19.994000 C 09:55:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 19.99 09:55:51 Integrated Voltage Measurement... 09:56:13 Voltage Offset Correction: v_off_ini = -0.000002165 V, v_off_fin = 0.000001068 V 09:56:13 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158515821 Vs 09:56:13 Integrated Voltage Measurement... 09:56:36 Voltage Offset Correction: v_off_ini = -0.000002223 V, v_off_fin = -0.000001053 V 09:56:36 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158485831 Vs 09:56:50 Temperature Measurement, Probe Number = 0, T = 20.066000 C 09:56:50 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:56:51 Temperature Measurement, Probe Number = 2, T = 20.074000 C 09:56:52 Temperature Measurement, Probe Number = 3, T = 20.002000 C 09:56:52 Temperature Measurement, Probe Number = 4, T = 20.046000 C 09:56:53 Temperature Measurement, Probe Number = 5, T = 19.995000 C 09:56:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 09:56:53 Integrated Voltage Measurement... 09:57:15 Voltage Offset Correction: v_off_ini = -0.000001777 V, v_off_fin = -0.000001499 V 09:57:15 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158540001 Vs 09:57:15 Integrated Voltage Measurement... 09:57:37 Voltage Offset Correction: v_off_ini = -0.000002406 V, v_off_fin = -0.000002106 V 09:57:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158493813 Vs 09:57:51 Temperature Measurement, Probe Number = 0, T = 20.083000 C 09:57:51 Temperature Measurement, Probe Number = 1, T = 20.042000 C 09:57:52 Temperature Measurement, Probe Number = 2, T = 20.076000 C 09:57:53 Temperature Measurement, Probe Number = 3, T = 20.006000 C 09:57:53 Temperature Measurement, Probe Number = 4, T = 20.048000 C 09:57:54 Temperature Measurement, Probe Number = 5, T = 19.995000 C 09:57:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 09:57:54 Integrated Voltage Measurement... 09:58:16 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000000841 V 09:58:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158529908 Vs 09:58:16 Integrated Voltage Measurement... 09:58:38 Voltage Offset Correction: v_off_ini = -0.000004169 V, v_off_fin = -0.000002955 V 09:58:38 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158474647 Vs 09:58:52 Temperature Measurement, Probe Number = 0, T = 20.099000 C 09:58:52 Temperature Measurement, Probe Number = 1, T = 20.045000 C 09:58:53 Temperature Measurement, Probe Number = 2, T = 20.077000 C 09:58:54 Temperature Measurement, Probe Number = 3, T = 20.009000 C 09:58:54 Temperature Measurement, Probe Number = 4, T = 20.050000 C 09:58:55 Temperature Measurement, Probe Number = 5, T = 19.997000 C 09:58:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 09:58:55 Integrated Voltage Measurement... 09:59:17 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = 0.000000965 V 09:59:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158500764 Vs 09:59:17 Integrated Voltage Measurement... 09:59:39 Voltage Offset Correction: v_off_ini = 0.000000702 V, v_off_fin = -0.000001961 V 09:59:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158514761 Vs 09:59:53 Temperature Measurement, Probe Number = 0, T = 20.094000 C 09:59:53 Temperature Measurement, Probe Number = 1, T = 20.045000 C 09:59:54 Temperature Measurement, Probe Number = 2, T = 20.080000 C 09:59:55 Temperature Measurement, Probe Number = 3, T = 20.010000 C 09:59:55 Temperature Measurement, Probe Number = 4, T = 20.050000 C 09:59:56 Temperature Measurement, Probe Number = 5, T = 19.996000 C 09:59:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 09:59:56 Integrated Voltage Measurement... 10:00:18 Voltage Offset Correction: v_off_ini = 0.000000271 V, v_off_fin = -0.000000373 V 10:00:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158480483 Vs 10:00:18 Integrated Voltage Measurement... 10:00:41 Voltage Offset Correction: v_off_ini = -0.000002619 V, v_off_fin = -0.000000468 V 10:00:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158492011 Vs 10:00:54 Temperature Measurement, Probe Number = 0, T = 20.151000 C 10:00:55 Temperature Measurement, Probe Number = 1, T = 20.042000 C 10:00:55 Temperature Measurement, Probe Number = 2, T = 20.074000 C 10:00:56 Temperature Measurement, Probe Number = 3, T = 20.017000 C 10:00:57 Temperature Measurement, Probe Number = 4, T = 20.050000 C 10:00:57 Temperature Measurement, Probe Number = 5, T = 19.996000 C 10:00:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 10:00:57 Integrated Voltage Measurement... 10:01:19 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = 0.000004125 V 10:01:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158479428 Vs 10:01:19 Integrated Voltage Measurement... 10:01:42 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = -0.000003401 V 10:01:42 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158493618 Vs 10:01:55 Temperature Measurement, Probe Number = 0, T = 20.154000 C 10:01:56 Temperature Measurement, Probe Number = 1, T = 20.040000 C 10:01:56 Temperature Measurement, Probe Number = 2, T = 20.072000 C 10:01:57 Temperature Measurement, Probe Number = 3, T = 20.019000 C 10:01:58 Temperature Measurement, Probe Number = 4, T = 20.047000 C 10:01:58 Temperature Measurement, Probe Number = 5, T = 19.994000 C 10:01:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 19.99 10:01:58 Integrated Voltage Measurement... 10:02:20 Voltage Offset Correction: v_off_ini = 0.000000921 V, v_off_fin = -0.000000029 V 10:02:20 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158494324 Vs 10:02:20 Integrated Voltage Measurement... 10:02:42 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000003036 V 10:02:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158516169 Vs 10:02:56 Temperature Measurement, Probe Number = 0, T = 20.146000 C 10:02:57 Temperature Measurement, Probe Number = 1, T = 20.043000 C 10:02:57 Temperature Measurement, Probe Number = 2, T = 20.075000 C 10:02:58 Temperature Measurement, Probe Number = 3, T = 20.021000 C 10:02:58 Temperature Measurement, Probe Number = 4, T = 20.048000 C 10:02:59 Temperature Measurement, Probe Number = 5, T = 19.996000 C 10:02:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 10:02:59 Integrated Voltage Measurement... 10:03:21 Voltage Offset Correction: v_off_ini = -0.000001822 V, v_off_fin = -0.000002517 V 10:03:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158528283 Vs 10:03:21 Integrated Voltage Measurement... 10:03:43 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000002582 V 10:03:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158488138 Vs 10:03:57 Temperature Measurement, Probe Number = 0, T = 20.156000 C 10:03:58 Temperature Measurement, Probe Number = 1, T = 20.040000 C 10:03:58 Temperature Measurement, Probe Number = 2, T = 20.072000 C 10:03:59 Temperature Measurement, Probe Number = 3, T = 20.018000 C 10:03:59 Temperature Measurement, Probe Number = 4, T = 20.048000 C 10:04:00 Temperature Measurement, Probe Number = 5, T = 19.995000 C 10:04:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 20.00 10:04:00 Integrated Voltage Measurement... 10:04:22 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000000212 V 10:04:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158521406 Vs 10:04:22 Integrated Voltage Measurement... 10:04:44 Voltage Offset Correction: v_off_ini = -0.000002546 V, v_off_fin = -0.000002363 V 10:04:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158495310 Vs 11:00:58 Temperature Measurement, Probe Number = 0, T = 20.668000 C 11:00:59 Temperature Measurement, Probe Number = 1, T = 20.084000 C 11:00:59 Temperature Measurement, Probe Number = 2, T = 20.119000 C 11:01:00 Temperature Measurement, Probe Number = 3, T = 20.134000 C 11:01:00 Temperature Measurement, Probe Number = 4, T = 20.091000 C 11:01:01 Temperature Measurement, Probe Number = 5, T = 20.033000 C 11:01:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.67 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 11:01:01 Integrated Voltage Measurement... 11:01:23 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = -0.000003081 V 11:01:23 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.158646283 Vs 11:01:23 Integrated Voltage Measurement... 11:01:46 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000002876 V 11:01:46 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158460679 Vs 11:01:59 Temperature Measurement, Probe Number = 0, T = 20.622000 C 11:02:00 Temperature Measurement, Probe Number = 1, T = 20.084000 C 11:02:00 Temperature Measurement, Probe Number = 2, T = 20.119000 C 11:02:01 Temperature Measurement, Probe Number = 3, T = 20.132000 C 11:02:02 Temperature Measurement, Probe Number = 4, T = 20.091000 C 11:02:02 Temperature Measurement, Probe Number = 5, T = 20.034000 C 11:02:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.62 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 11:02:02 Integrated Voltage Measurement... 11:02:24 Voltage Offset Correction: v_off_ini = -0.000002474 V, v_off_fin = -0.000001815 V 11:02:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158513178 Vs 11:02:25 Integrated Voltage Measurement... 11:02:47 Voltage Offset Correction: v_off_ini = -0.000002671 V, v_off_fin = -0.000001259 V 11:02:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447820 Vs 11:03:01 Temperature Measurement, Probe Number = 0, T = 20.633000 C 11:03:02 Temperature Measurement, Probe Number = 1, T = 20.089000 C 11:03:02 Temperature Measurement, Probe Number = 2, T = 20.124000 C 11:03:03 Temperature Measurement, Probe Number = 3, T = 20.135000 C 11:03:04 Temperature Measurement, Probe Number = 4, T = 20.094000 C 11:03:04 Temperature Measurement, Probe Number = 5, T = 20.037000 C 11:03:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.63 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 11:03:04 Integrated Voltage Measurement... 11:03:26 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = 0.000001200 V 11:03:27 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158483412 Vs 11:03:27 Integrated Voltage Measurement... 11:03:49 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000002642 V 11:03:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158462116 Vs 11:04:03 Temperature Measurement, Probe Number = 0, T = 20.642000 C 11:04:03 Temperature Measurement, Probe Number = 1, T = 20.093000 C 11:04:04 Temperature Measurement, Probe Number = 2, T = 20.126000 C 11:04:05 Temperature Measurement, Probe Number = 3, T = 20.133000 C 11:04:05 Temperature Measurement, Probe Number = 4, T = 20.098000 C 11:04:06 Temperature Measurement, Probe Number = 5, T = 20.039000 C 11:04:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.64 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 11:04:06 Integrated Voltage Measurement... 11:04:28 Voltage Offset Correction: v_off_ini = -0.000001866 V, v_off_fin = 0.000001171 V 11:04:28 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158510413 Vs 11:04:28 Integrated Voltage Measurement... 11:04:51 Voltage Offset Correction: v_off_ini = -0.000002144 V, v_off_fin = -0.000001222 V 11:04:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442549 Vs 11:05:04 Temperature Measurement, Probe Number = 0, T = 20.661000 C 11:05:05 Temperature Measurement, Probe Number = 1, T = 20.093000 C 11:05:05 Temperature Measurement, Probe Number = 2, T = 20.128000 C 11:05:06 Temperature Measurement, Probe Number = 3, T = 20.133000 C 11:05:07 Temperature Measurement, Probe Number = 4, T = 20.098000 C 11:05:07 Temperature Measurement, Probe Number = 5, T = 20.040000 C 11:05:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.66 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 11:05:07 Integrated Voltage Measurement... 11:05:29 Voltage Offset Correction: v_off_ini = -0.000001076 V, v_off_fin = 0.000000059 V 11:05:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158483774 Vs 11:05:29 Integrated Voltage Measurement... 11:05:52 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000001997 V 11:05:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447043 Vs 11:06:05 Temperature Measurement, Probe Number = 0, T = 20.641000 C 11:06:06 Temperature Measurement, Probe Number = 1, T = 20.092000 C 11:06:06 Temperature Measurement, Probe Number = 2, T = 20.128000 C 11:06:07 Temperature Measurement, Probe Number = 3, T = 20.131000 C 11:06:07 Temperature Measurement, Probe Number = 4, T = 20.098000 C 11:06:08 Temperature Measurement, Probe Number = 5, T = 20.039000 C 11:06:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.64 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 11:06:08 Integrated Voltage Measurement... 11:06:30 Voltage Offset Correction: v_off_ini = -0.000002253 V, v_off_fin = 0.000000688 V 11:06:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158470458 Vs 11:06:30 Integrated Voltage Measurement... 11:06:53 Voltage Offset Correction: v_off_ini = -0.000002868 V, v_off_fin = -0.000001968 V 11:06:53 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158432859 Vs 11:07:07 Temperature Measurement, Probe Number = 0, T = 20.587000 C 11:07:08 Temperature Measurement, Probe Number = 1, T = 20.090000 C 11:07:08 Temperature Measurement, Probe Number = 2, T = 20.125000 C 11:07:09 Temperature Measurement, Probe Number = 3, T = 20.127000 C 11:07:09 Temperature Measurement, Probe Number = 4, T = 20.097000 C 11:07:10 Temperature Measurement, Probe Number = 5, T = 20.039000 C 11:07:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.59 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 11:07:10 Integrated Voltage Measurement... 11:07:40 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = 0.000001405 V 11:07:40 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158447140 Vs 11:07:40 Integrated Voltage Measurement... 11:08:03 Voltage Offset Correction: v_off_ini = -0.000001105 V, v_off_fin = 0.000000322 V 11:08:03 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158462508 Vs 11:08:17 Temperature Measurement, Probe Number = 0, T = 20.574000 C 11:08:17 Temperature Measurement, Probe Number = 1, T = 20.089000 C 11:08:18 Temperature Measurement, Probe Number = 2, T = 20.126000 C 11:08:19 Temperature Measurement, Probe Number = 3, T = 20.126000 C 11:08:19 Temperature Measurement, Probe Number = 4, T = 20.096000 C 11:08:20 Temperature Measurement, Probe Number = 5, T = 20.039000 C 11:08:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.57 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 11:08:20 Integrated Voltage Measurement... 11:08:42 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000000446 V 11:08:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158448358 Vs 11:08:42 Integrated Voltage Measurement... 11:09:05 Voltage Offset Correction: v_off_ini = -0.000000000 V, v_off_fin = -0.000003812 V 11:09:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448627 Vs 11:09:18 Temperature Measurement, Probe Number = 0, T = 20.510000 C 11:09:19 Temperature Measurement, Probe Number = 1, T = 20.087000 C 11:09:19 Temperature Measurement, Probe Number = 2, T = 20.123000 C 11:09:20 Temperature Measurement, Probe Number = 3, T = 20.120000 C 11:09:21 Temperature Measurement, Probe Number = 4, T = 20.094000 C 11:09:21 Temperature Measurement, Probe Number = 5, T = 20.037000 C 11:09:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.51 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 11:09:21 Integrated Voltage Measurement... 11:09:43 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = 0.000001164 V 11:09:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158470324 Vs 11:09:44 Integrated Voltage Measurement... 11:10:06 Voltage Offset Correction: v_off_ini = -0.000001075 V, v_off_fin = -0.000004865 V 11:10:06 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158461960 Vs 11:10:20 Temperature Measurement, Probe Number = 0, T = 20.397000 C 11:10:20 Temperature Measurement, Probe Number = 1, T = 20.083000 C 11:10:21 Temperature Measurement, Probe Number = 2, T = 20.115000 C 11:10:22 Temperature Measurement, Probe Number = 3, T = 20.118000 C 11:10:22 Temperature Measurement, Probe Number = 4, T = 20.085000 C 11:10:23 Temperature Measurement, Probe Number = 5, T = 20.035000 C 11:10:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.40 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 11:10:23 Integrated Voltage Measurement... 11:10:45 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000000007 V 11:10:45 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158463840 Vs 11:10:45 Integrated Voltage Measurement... 11:11:07 Voltage Offset Correction: v_off_ini = -0.000004156 V, v_off_fin = -0.000001610 V 11:11:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398167 Vs 12:07:21 Temperature Measurement, Probe Number = 0, T = 19.866000 C 12:07:22 Temperature Measurement, Probe Number = 1, T = 20.078000 C 12:07:22 Temperature Measurement, Probe Number = 2, T = 20.113000 C 12:07:23 Temperature Measurement, Probe Number = 3, T = 20.133000 C 12:07:24 Temperature Measurement, Probe Number = 4, T = 20.097000 C 12:07:24 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:07:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 12:07:24 Integrated Voltage Measurement... 12:07:46 Voltage Offset Correction: v_off_ini = 0.000001208 V, v_off_fin = 0.000000168 V 12:07:47 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158465383 Vs 12:07:47 Integrated Voltage Measurement... 12:08:09 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000001676 V 12:08:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158470027 Vs 12:08:23 Temperature Measurement, Probe Number = 0, T = 19.887000 C 12:08:24 Temperature Measurement, Probe Number = 1, T = 20.077000 C 12:08:24 Temperature Measurement, Probe Number = 2, T = 20.118000 C 12:08:25 Temperature Measurement, Probe Number = 3, T = 20.131000 C 12:08:25 Temperature Measurement, Probe Number = 4, T = 20.099000 C 12:08:26 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:08:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 12:08:26 Integrated Voltage Measurement... 12:08:48 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000000476 V 12:08:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158475001 Vs 12:08:48 Integrated Voltage Measurement... 12:09:11 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = 0.000000373 V 12:09:11 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158457556 Vs 12:09:25 Temperature Measurement, Probe Number = 0, T = 19.905000 C 12:09:25 Temperature Measurement, Probe Number = 1, T = 20.077000 C 12:09:26 Temperature Measurement, Probe Number = 2, T = 20.122000 C 12:09:27 Temperature Measurement, Probe Number = 3, T = 20.129000 C 12:09:27 Temperature Measurement, Probe Number = 4, T = 20.100000 C 12:09:28 Temperature Measurement, Probe Number = 5, T = 20.047000 C 12:09:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 12:09:28 Integrated Voltage Measurement... 12:09:50 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = -0.000001010 V 12:09:50 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158465285 Vs 12:09:50 Integrated Voltage Measurement... 12:10:12 Voltage Offset Correction: v_off_ini = -0.000002356 V, v_off_fin = -0.000002458 V 12:10:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427787 Vs 12:10:26 Temperature Measurement, Probe Number = 0, T = 19.939000 C 12:10:27 Temperature Measurement, Probe Number = 1, T = 20.083000 C 12:10:27 Temperature Measurement, Probe Number = 2, T = 20.128000 C 12:10:28 Temperature Measurement, Probe Number = 3, T = 20.134000 C 12:10:29 Temperature Measurement, Probe Number = 4, T = 20.101000 C 12:10:29 Temperature Measurement, Probe Number = 5, T = 20.048000 C 12:10:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 12:10:29 Integrated Voltage Measurement... 12:10:52 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = 0.000000300 V 12:10:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158464761 Vs 12:10:52 Integrated Voltage Measurement... 12:11:14 Voltage Offset Correction: v_off_ini = 0.000001054 V, v_off_fin = -0.000002225 V 12:11:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158474787 Vs 12:11:28 Temperature Measurement, Probe Number = 0, T = 19.953000 C 12:11:28 Temperature Measurement, Probe Number = 1, T = 20.085000 C 12:11:29 Temperature Measurement, Probe Number = 2, T = 20.123000 C 12:11:30 Temperature Measurement, Probe Number = 3, T = 20.133000 C 12:11:30 Temperature Measurement, Probe Number = 4, T = 20.103000 C 12:11:31 Temperature Measurement, Probe Number = 5, T = 20.050000 C 12:11:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 12:11:31 Integrated Voltage Measurement... 12:11:53 Voltage Offset Correction: v_off_ini = -0.000000688 V, v_off_fin = -0.000000666 V 12:11:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158457416 Vs 12:11:53 Integrated Voltage Measurement... 12:12:15 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001288 V 12:12:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158457181 Vs 12:12:29 Temperature Measurement, Probe Number = 0, T = 19.894000 C 12:12:30 Temperature Measurement, Probe Number = 1, T = 20.077000 C 12:12:30 Temperature Measurement, Probe Number = 2, T = 20.109000 C 12:12:31 Temperature Measurement, Probe Number = 3, T = 20.130000 C 12:12:31 Temperature Measurement, Probe Number = 4, T = 20.095000 C 12:12:32 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:12:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 12:12:32 Integrated Voltage Measurement... 12:12:54 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000000922 V 12:12:54 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158478071 Vs 12:12:54 Integrated Voltage Measurement... 12:13:17 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000002618 V 12:13:17 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158449362 Vs 12:13:31 Temperature Measurement, Probe Number = 0, T = 19.855000 C 12:13:31 Temperature Measurement, Probe Number = 1, T = 20.076000 C 12:13:32 Temperature Measurement, Probe Number = 2, T = 20.107000 C 12:13:32 Temperature Measurement, Probe Number = 3, T = 20.123000 C 12:13:33 Temperature Measurement, Probe Number = 4, T = 20.093000 C 12:13:34 Temperature Measurement, Probe Number = 5, T = 20.044000 C 12:13:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 12:13:34 Integrated Voltage Measurement... 12:13:56 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000000615 V 12:13:56 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158465339 Vs 12:13:56 Integrated Voltage Measurement... 12:14:19 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = -0.000002238 V 12:14:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158484745 Vs 12:14:33 Temperature Measurement, Probe Number = 0, T = 19.806000 C 12:14:33 Temperature Measurement, Probe Number = 1, T = 20.074000 C 12:14:34 Temperature Measurement, Probe Number = 2, T = 20.107000 C 12:14:34 Temperature Measurement, Probe Number = 3, T = 20.117000 C 12:14:35 Temperature Measurement, Probe Number = 4, T = 20.089000 C 12:14:36 Temperature Measurement, Probe Number = 5, T = 20.042000 C 12:14:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.81 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 12:14:36 Integrated Voltage Measurement... 12:14:58 Voltage Offset Correction: v_off_ini = -0.000001917 V, v_off_fin = -0.000000644 V 12:14:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158485786 Vs 12:14:58 Integrated Voltage Measurement... 12:15:21 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000001148 V 12:15:21 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158455686 Vs 12:15:34 Temperature Measurement, Probe Number = 0, T = 19.771000 C 12:15:35 Temperature Measurement, Probe Number = 1, T = 20.070000 C 12:15:36 Temperature Measurement, Probe Number = 2, T = 20.103000 C 12:15:36 Temperature Measurement, Probe Number = 3, T = 20.116000 C 12:15:37 Temperature Measurement, Probe Number = 4, T = 20.091000 C 12:15:37 Temperature Measurement, Probe Number = 5, T = 20.042000 C 12:15:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 12:15:38 Integrated Voltage Measurement... 12:16:00 Voltage Offset Correction: v_off_ini = -0.000001404 V, v_off_fin = 0.000000161 V 12:16:00 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158445502 Vs 12:16:00 Integrated Voltage Measurement... 12:16:22 Voltage Offset Correction: v_off_ini = 0.000000541 V, v_off_fin = -0.000005368 V 12:16:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443506 Vs 12:16:36 Temperature Measurement, Probe Number = 0, T = 19.798000 C 12:16:37 Temperature Measurement, Probe Number = 1, T = 20.075000 C 12:16:37 Temperature Measurement, Probe Number = 2, T = 20.115000 C 12:16:38 Temperature Measurement, Probe Number = 3, T = 20.127000 C 12:16:38 Temperature Measurement, Probe Number = 4, T = 20.093000 C 12:16:39 Temperature Measurement, Probe Number = 5, T = 20.042000 C 12:16:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.80 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 12:16:39 Integrated Voltage Measurement... 12:17:01 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = 0.000000987 V 12:17:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158475179 Vs 12:17:01 Integrated Voltage Measurement... 12:17:24 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = -0.000000878 V 12:17:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158482156 Vs 13:13:37 Temperature Measurement, Probe Number = 0, T = 20.202000 C 13:13:38 Temperature Measurement, Probe Number = 1, T = 20.103000 C 13:13:38 Temperature Measurement, Probe Number = 2, T = 20.142000 C 13:13:39 Temperature Measurement, Probe Number = 3, T = 20.190000 C 13:13:40 Temperature Measurement, Probe Number = 4, T = 20.124000 C 13:13:40 Temperature Measurement, Probe Number = 5, T = 20.069000 C 13:13:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.19 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:13:40 Integrated Voltage Measurement... 13:14:02 Voltage Offset Correction: v_off_ini = 0.000000681 V, v_off_fin = 0.000000059 V 13:14:03 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158533505 Vs 13:14:03 Integrated Voltage Measurement... 13:14:25 Voltage Offset Correction: v_off_ini = 0.000001581 V, v_off_fin = -0.000002408 V 13:14:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158466538 Vs 13:14:39 Temperature Measurement, Probe Number = 0, T = 20.133000 C 13:14:39 Temperature Measurement, Probe Number = 1, T = 20.103000 C 13:14:40 Temperature Measurement, Probe Number = 2, T = 20.147000 C 13:14:40 Temperature Measurement, Probe Number = 3, T = 20.185000 C 13:14:41 Temperature Measurement, Probe Number = 4, T = 20.121000 C 13:14:42 Temperature Measurement, Probe Number = 5, T = 20.068000 C 13:14:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:14:42 Integrated Voltage Measurement... 13:15:04 Voltage Offset Correction: v_off_ini = -0.000000227 V, v_off_fin = -0.000000702 V 13:15:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158478485 Vs 13:15:04 Integrated Voltage Measurement... 13:15:27 Voltage Offset Correction: v_off_ini = -0.000002194 V, v_off_fin = -0.000002633 V 13:15:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439143 Vs 13:15:40 Temperature Measurement, Probe Number = 0, T = 20.097000 C 13:15:41 Temperature Measurement, Probe Number = 1, T = 20.105000 C 13:15:41 Temperature Measurement, Probe Number = 2, T = 20.139000 C 13:15:42 Temperature Measurement, Probe Number = 3, T = 20.179000 C 13:15:43 Temperature Measurement, Probe Number = 4, T = 20.117000 C 13:15:43 Temperature Measurement, Probe Number = 5, T = 20.067000 C 13:15:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:15:43 Integrated Voltage Measurement... 13:16:05 Voltage Offset Correction: v_off_ini = -0.000000659 V, v_off_fin = 0.000000234 V 13:16:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453294 Vs 13:16:06 Integrated Voltage Measurement... 13:16:28 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000002831 V 13:16:28 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158451710 Vs 13:16:42 Temperature Measurement, Probe Number = 0, T = 20.096000 C 13:16:42 Temperature Measurement, Probe Number = 1, T = 20.101000 C 13:16:43 Temperature Measurement, Probe Number = 2, T = 20.144000 C 13:16:43 Temperature Measurement, Probe Number = 3, T = 20.177000 C 13:16:44 Temperature Measurement, Probe Number = 4, T = 20.118000 C 13:16:45 Temperature Measurement, Probe Number = 5, T = 20.066000 C 13:16:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:16:45 Integrated Voltage Measurement... 13:17:07 Voltage Offset Correction: v_off_ini = -0.000002867 V, v_off_fin = -0.000000761 V 13:17:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158469280 Vs 13:17:07 Integrated Voltage Measurement... 13:17:29 Voltage Offset Correction: v_off_ini = -0.000000731 V, v_off_fin = -0.000001799 V 13:17:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158461491 Vs 13:17:43 Temperature Measurement, Probe Number = 0, T = 20.061000 C 13:17:44 Temperature Measurement, Probe Number = 1, T = 20.099000 C 13:17:44 Temperature Measurement, Probe Number = 2, T = 20.141000 C 13:17:45 Temperature Measurement, Probe Number = 3, T = 20.174000 C 13:17:46 Temperature Measurement, Probe Number = 4, T = 20.119000 C 13:17:46 Temperature Measurement, Probe Number = 5, T = 20.066000 C 13:17:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:17:46 Integrated Voltage Measurement... 13:18:08 Voltage Offset Correction: v_off_ini = -0.000003123 V, v_off_fin = -0.000004345 V 13:18:09 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158490864 Vs 13:18:09 Integrated Voltage Measurement... 13:18:31 Voltage Offset Correction: v_off_ini = -0.000000154 V, v_off_fin = -0.000005273 V 13:18:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434182 Vs 13:18:45 Temperature Measurement, Probe Number = 0, T = 20.022000 C 13:18:45 Temperature Measurement, Probe Number = 1, T = 20.099000 C 13:18:46 Temperature Measurement, Probe Number = 2, T = 20.142000 C 13:18:47 Temperature Measurement, Probe Number = 3, T = 20.171000 C 13:18:47 Temperature Measurement, Probe Number = 4, T = 20.118000 C 13:18:48 Temperature Measurement, Probe Number = 5, T = 20.068000 C 13:18:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:18:48 Integrated Voltage Measurement... 13:19:10 Voltage Offset Correction: v_off_ini = -0.000001873 V, v_off_fin = -0.000002048 V 13:19:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158505957 Vs 13:19:10 Integrated Voltage Measurement... 13:19:32 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000002195 V 13:19:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433733 Vs 13:19:46 Temperature Measurement, Probe Number = 0, T = 20.020000 C 13:19:46 Temperature Measurement, Probe Number = 1, T = 20.108000 C 13:19:47 Temperature Measurement, Probe Number = 2, T = 20.147000 C 13:19:48 Temperature Measurement, Probe Number = 3, T = 20.181000 C 13:19:48 Temperature Measurement, Probe Number = 4, T = 20.121000 C 13:19:49 Temperature Measurement, Probe Number = 5, T = 20.069000 C 13:19:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:19:49 Integrated Voltage Measurement... 13:20:11 Voltage Offset Correction: v_off_ini = -0.000000783 V, v_off_fin = 0.000000702 V 13:20:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158466439 Vs 13:20:11 Integrated Voltage Measurement... 13:20:34 Voltage Offset Correction: v_off_ini = -0.000000592 V, v_off_fin = -0.000001931 V 13:20:34 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158444412 Vs 13:20:48 Temperature Measurement, Probe Number = 0, T = 20.018000 C 13:20:48 Temperature Measurement, Probe Number = 1, T = 20.107000 C 13:20:49 Temperature Measurement, Probe Number = 2, T = 20.149000 C 13:20:50 Temperature Measurement, Probe Number = 3, T = 20.188000 C 13:20:50 Temperature Measurement, Probe Number = 4, T = 20.122000 C 13:20:51 Temperature Measurement, Probe Number = 5, T = 20.069000 C 13:20:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.19 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:20:51 Integrated Voltage Measurement... 13:21:13 Voltage Offset Correction: v_off_ini = -0.000002290 V, v_off_fin = 0.000000410 V 13:21:13 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158425892 Vs 13:21:13 Integrated Voltage Measurement... 13:21:36 Voltage Offset Correction: v_off_ini = 0.000001953 V, v_off_fin = -0.000002356 V 13:21:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158464919 Vs 13:21:49 Temperature Measurement, Probe Number = 0, T = 20.013000 C 13:21:50 Temperature Measurement, Probe Number = 1, T = 20.102000 C 13:21:51 Temperature Measurement, Probe Number = 2, T = 20.148000 C 13:21:51 Temperature Measurement, Probe Number = 3, T = 20.176000 C 13:21:52 Temperature Measurement, Probe Number = 4, T = 20.122000 C 13:21:52 Temperature Measurement, Probe Number = 5, T = 20.067000 C 13:21:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:21:52 Integrated Voltage Measurement... 13:22:15 Voltage Offset Correction: v_off_ini = -0.000001332 V, v_off_fin = -0.000001376 V 13:22:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158472672 Vs 13:22:15 Integrated Voltage Measurement... 13:22:37 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000001288 V 13:22:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158460085 Vs 13:22:51 Temperature Measurement, Probe Number = 0, T = 20.024000 C 13:22:51 Temperature Measurement, Probe Number = 1, T = 20.100000 C 13:22:52 Temperature Measurement, Probe Number = 2, T = 20.148000 C 13:22:53 Temperature Measurement, Probe Number = 3, T = 20.179000 C 13:22:53 Temperature Measurement, Probe Number = 4, T = 20.120000 C 13:22:54 Temperature Measurement, Probe Number = 5, T = 20.067000 C 13:22:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 13:22:54 Integrated Voltage Measurement... 13:23:16 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = 0.000003717 V 13:23:16 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158420603 Vs 13:23:16 Integrated Voltage Measurement... 13:23:39 Voltage Offset Correction: v_off_ini = -0.000004274 V, v_off_fin = -0.000002151 V 13:23:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424917 Vs 14:19:52 Temperature Measurement, Probe Number = 0, T = 20.240000 C 14:19:53 Temperature Measurement, Probe Number = 1, T = 20.131000 C 14:19:53 Temperature Measurement, Probe Number = 2, T = 20.169000 C 14:19:54 Temperature Measurement, Probe Number = 3, T = 20.219000 C 14:19:55 Temperature Measurement, Probe Number = 4, T = 20.148000 C 14:19:55 Temperature Measurement, Probe Number = 5, T = 20.090000 C 14:19:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:19:55 Integrated Voltage Measurement... 14:20:18 Voltage Offset Correction: v_off_ini = -0.000002378 V, v_off_fin = -0.000002948 V 14:20:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.158537021 Vs 14:20:18 Integrated Voltage Measurement... 14:20:40 Voltage Offset Correction: v_off_ini = 0.000000754 V, v_off_fin = -0.000002048 V 14:20:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436951 Vs 14:20:54 Temperature Measurement, Probe Number = 0, T = 20.303000 C 14:20:54 Temperature Measurement, Probe Number = 1, T = 20.131000 C 14:20:55 Temperature Measurement, Probe Number = 2, T = 20.170000 C 14:20:56 Temperature Measurement, Probe Number = 3, T = 20.216000 C 14:20:56 Temperature Measurement, Probe Number = 4, T = 20.148000 C 14:20:57 Temperature Measurement, Probe Number = 5, T = 20.091000 C 14:20:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:20:57 Integrated Voltage Measurement... 14:21:19 Voltage Offset Correction: v_off_ini = -0.000001214 V, v_off_fin = 0.000000234 V 14:21:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158458435 Vs 14:21:19 Integrated Voltage Measurement... 14:21:41 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000002443 V 14:21:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441032 Vs 14:21:55 Temperature Measurement, Probe Number = 0, T = 20.297000 C 14:21:55 Temperature Measurement, Probe Number = 1, T = 20.133000 C 14:21:56 Temperature Measurement, Probe Number = 2, T = 20.174000 C 14:21:57 Temperature Measurement, Probe Number = 3, T = 20.218000 C 14:21:57 Temperature Measurement, Probe Number = 4, T = 20.150000 C 14:21:58 Temperature Measurement, Probe Number = 5, T = 20.092000 C 14:21:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:21:58 Integrated Voltage Measurement... 14:22:20 Voltage Offset Correction: v_off_ini = -0.000001734 V, v_off_fin = -0.000001170 V 14:22:20 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158473446 Vs 14:22:20 Integrated Voltage Measurement... 14:22:42 Voltage Offset Correction: v_off_ini = -0.000002253 V, v_off_fin = -0.000001916 V 14:22:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414311 Vs 14:22:56 Temperature Measurement, Probe Number = 0, T = 20.315000 C 14:22:56 Temperature Measurement, Probe Number = 1, T = 20.135000 C 14:22:57 Temperature Measurement, Probe Number = 2, T = 20.174000 C 14:22:58 Temperature Measurement, Probe Number = 3, T = 20.227000 C 14:22:58 Temperature Measurement, Probe Number = 4, T = 20.150000 C 14:22:59 Temperature Measurement, Probe Number = 5, T = 20.093000 C 14:22:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.23 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:22:59 Integrated Voltage Measurement... 14:23:21 Voltage Offset Correction: v_off_ini = -0.000003592 V, v_off_fin = -0.000000124 V 14:23:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158464206 Vs 14:23:21 Integrated Voltage Measurement... 14:23:43 Voltage Offset Correction: v_off_ini = -0.000000358 V, v_off_fin = -0.000000878 V 14:23:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158429416 Vs 14:23:57 Temperature Measurement, Probe Number = 0, T = 20.341000 C 14:23:58 Temperature Measurement, Probe Number = 1, T = 20.134000 C 14:23:59 Temperature Measurement, Probe Number = 2, T = 20.171000 C 14:23:59 Temperature Measurement, Probe Number = 3, T = 20.237000 C 14:24:00 Temperature Measurement, Probe Number = 4, T = 20.151000 C 14:24:00 Temperature Measurement, Probe Number = 5, T = 20.094000 C 14:24:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.34 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.24 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:24:00 Integrated Voltage Measurement... 14:24:23 Voltage Offset Correction: v_off_ini = -0.000000746 V, v_off_fin = 0.000000168 V 14:24:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453884 Vs 14:24:23 Integrated Voltage Measurement... 14:24:45 Voltage Offset Correction: v_off_ini = -0.000001975 V, v_off_fin = -0.000002911 V 14:24:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417941 Vs 14:24:59 Temperature Measurement, Probe Number = 0, T = 20.347000 C 14:25:00 Temperature Measurement, Probe Number = 1, T = 20.133000 C 14:25:00 Temperature Measurement, Probe Number = 2, T = 20.170000 C 14:25:01 Temperature Measurement, Probe Number = 3, T = 20.236000 C 14:25:01 Temperature Measurement, Probe Number = 4, T = 20.151000 C 14:25:02 Temperature Measurement, Probe Number = 5, T = 20.095000 C 14:25:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.24 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:25:02 Integrated Voltage Measurement... 14:25:24 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000001419 V 14:25:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158468203 Vs 14:25:24 Integrated Voltage Measurement... 14:25:47 Voltage Offset Correction: v_off_ini = -0.000002107 V, v_off_fin = -0.000001821 V 14:25:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440256 Vs 14:26:00 Temperature Measurement, Probe Number = 0, T = 20.355000 C 14:26:01 Temperature Measurement, Probe Number = 1, T = 20.135000 C 14:26:01 Temperature Measurement, Probe Number = 2, T = 20.174000 C 14:26:02 Temperature Measurement, Probe Number = 3, T = 20.237000 C 14:26:03 Temperature Measurement, Probe Number = 4, T = 20.152000 C 14:26:03 Temperature Measurement, Probe Number = 5, T = 20.095000 C 14:26:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.36 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.24 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 14:26:03 Integrated Voltage Measurement... 14:26:25 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = 0.000000285 V 14:26:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158444078 Vs 14:26:25 Integrated Voltage Measurement... 14:26:48 Voltage Offset Correction: v_off_ini = -0.000000037 V, v_off_fin = -0.000002779 V 14:26:48 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158440388 Vs 14:27:01 Temperature Measurement, Probe Number = 0, T = 20.322000 C 14:27:02 Temperature Measurement, Probe Number = 1, T = 20.138000 C 14:27:02 Temperature Measurement, Probe Number = 2, T = 20.177000 C 14:27:03 Temperature Measurement, Probe Number = 3, T = 20.239000 C 14:27:04 Temperature Measurement, Probe Number = 4, T = 20.154000 C 14:27:04 Temperature Measurement, Probe Number = 5, T = 20.098000 C 14:27:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.24 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.10 14:27:04 Integrated Voltage Measurement... 14:27:26 Voltage Offset Correction: v_off_ini = -0.000000687 V, v_off_fin = -0.000000410 V 14:27:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158470430 Vs 14:27:26 Integrated Voltage Measurement... 14:27:49 Voltage Offset Correction: v_off_ini = -0.000000029 V, v_off_fin = -0.000002070 V 14:27:49 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158439530 Vs 14:28:03 Temperature Measurement, Probe Number = 0, T = 20.310000 C 14:28:03 Temperature Measurement, Probe Number = 1, T = 20.138000 C 14:28:04 Temperature Measurement, Probe Number = 2, T = 20.177000 C 14:28:05 Temperature Measurement, Probe Number = 3, T = 20.230000 C 14:28:05 Temperature Measurement, Probe Number = 4, T = 20.155000 C 14:28:06 Temperature Measurement, Probe Number = 5, T = 20.097000 C 14:28:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.23 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 14:28:06 Integrated Voltage Measurement... 14:28:28 Voltage Offset Correction: v_off_ini = -0.000001953 V, v_off_fin = -0.000000768 V 14:28:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158473131 Vs 14:28:28 Integrated Voltage Measurement... 14:28:50 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000001770 V 14:28:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158429650 Vs 14:29:04 Temperature Measurement, Probe Number = 0, T = 20.297000 C 14:29:04 Temperature Measurement, Probe Number = 1, T = 20.136000 C 14:29:05 Temperature Measurement, Probe Number = 2, T = 20.176000 C 14:29:06 Temperature Measurement, Probe Number = 3, T = 20.224000 C 14:29:06 Temperature Measurement, Probe Number = 4, T = 20.154000 C 14:29:07 Temperature Measurement, Probe Number = 5, T = 20.096000 C 14:29:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.10 14:29:07 Integrated Voltage Measurement... 14:29:29 Voltage Offset Correction: v_off_ini = -0.000001880 V, v_off_fin = -0.000000702 V 14:29:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158450901 Vs 14:29:29 Integrated Voltage Measurement... 14:29:51 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000002662 V 14:29:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427669 Vs 15:26:05 Temperature Measurement, Probe Number = 0, T = 20.313000 C 15:26:05 Temperature Measurement, Probe Number = 1, T = 20.159000 C 15:26:06 Temperature Measurement, Probe Number = 2, T = 20.198000 C 15:26:07 Temperature Measurement, Probe Number = 3, T = 20.219000 C 15:26:07 Temperature Measurement, Probe Number = 4, T = 20.179000 C 15:26:08 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:26:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:26:08 Integrated Voltage Measurement... 15:26:30 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = 0.000000344 V 15:26:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.158497506 Vs 15:26:30 Integrated Voltage Measurement... 15:26:52 Voltage Offset Correction: v_off_ini = 0.000000842 V, v_off_fin = -0.000002965 V 15:26:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444414 Vs 15:27:06 Temperature Measurement, Probe Number = 0, T = 20.345000 C 15:27:07 Temperature Measurement, Probe Number = 1, T = 20.161000 C 15:27:07 Temperature Measurement, Probe Number = 2, T = 20.200000 C 15:27:08 Temperature Measurement, Probe Number = 3, T = 20.219000 C 15:27:08 Temperature Measurement, Probe Number = 4, T = 20.182000 C 15:27:09 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:27:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.34 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:27:09 Integrated Voltage Measurement... 15:27:31 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000001845 V 15:27:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158436693 Vs 15:27:32 Integrated Voltage Measurement... 15:27:54 Voltage Offset Correction: v_off_ini = 0.000002833 V, v_off_fin = -0.000002401 V 15:27:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158458561 Vs 15:28:07 Temperature Measurement, Probe Number = 0, T = 20.354000 C 15:28:08 Temperature Measurement, Probe Number = 1, T = 20.159000 C 15:28:09 Temperature Measurement, Probe Number = 2, T = 20.202000 C 15:28:09 Temperature Measurement, Probe Number = 3, T = 20.220000 C 15:28:10 Temperature Measurement, Probe Number = 4, T = 20.180000 C 15:28:10 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:28:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:28:10 Integrated Voltage Measurement... 15:28:33 Voltage Offset Correction: v_off_ini = -0.000000242 V, v_off_fin = -0.000000644 V 15:28:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158443722 Vs 15:28:33 Integrated Voltage Measurement... 15:28:55 Voltage Offset Correction: v_off_ini = -0.000001501 V, v_off_fin = -0.000002379 V 15:28:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424514 Vs 15:29:09 Temperature Measurement, Probe Number = 0, T = 20.367000 C 15:29:10 Temperature Measurement, Probe Number = 1, T = 20.161000 C 15:29:10 Temperature Measurement, Probe Number = 2, T = 20.200000 C 15:29:11 Temperature Measurement, Probe Number = 3, T = 20.220000 C 15:29:11 Temperature Measurement, Probe Number = 4, T = 20.182000 C 15:29:12 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:29:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.37 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:29:12 Integrated Voltage Measurement... 15:29:34 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000000732 V 15:29:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453769 Vs 15:29:34 Integrated Voltage Measurement... 15:29:57 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000000739 V 15:29:57 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158445049 Vs 15:30:10 Temperature Measurement, Probe Number = 0, T = 20.351000 C 15:30:11 Temperature Measurement, Probe Number = 1, T = 20.160000 C 15:30:11 Temperature Measurement, Probe Number = 2, T = 20.199000 C 15:30:12 Temperature Measurement, Probe Number = 3, T = 20.220000 C 15:30:13 Temperature Measurement, Probe Number = 4, T = 20.182000 C 15:30:13 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:30:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:30:13 Integrated Voltage Measurement... 15:30:36 Voltage Offset Correction: v_off_ini = -0.000001581 V, v_off_fin = -0.000001625 V 15:30:36 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158448731 Vs 15:30:36 Integrated Voltage Measurement... 15:30:58 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = -0.000001706 V 15:30:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444773 Vs 15:31:12 Temperature Measurement, Probe Number = 0, T = 20.348000 C 15:31:12 Temperature Measurement, Probe Number = 1, T = 20.159000 C 15:31:13 Temperature Measurement, Probe Number = 2, T = 20.199000 C 15:31:14 Temperature Measurement, Probe Number = 3, T = 20.220000 C 15:31:14 Temperature Measurement, Probe Number = 4, T = 20.181000 C 15:31:15 Temperature Measurement, Probe Number = 5, T = 20.120000 C 15:31:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:31:15 Integrated Voltage Measurement... 15:31:37 Voltage Offset Correction: v_off_ini = -0.000000271 V, v_off_fin = 0.000000454 V 15:31:37 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158425890 Vs 15:31:37 Integrated Voltage Measurement... 15:31:59 Voltage Offset Correction: v_off_ini = 0.000001245 V, v_off_fin = -0.000002438 V 15:32:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427215 Vs 15:32:13 Temperature Measurement, Probe Number = 0, T = 20.330000 C 15:32:14 Temperature Measurement, Probe Number = 1, T = 20.159000 C 15:32:14 Temperature Measurement, Probe Number = 2, T = 20.200000 C 15:32:15 Temperature Measurement, Probe Number = 3, T = 20.218000 C 15:32:15 Temperature Measurement, Probe Number = 4, T = 20.180000 C 15:32:16 Temperature Measurement, Probe Number = 5, T = 20.121000 C 15:32:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.33 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:32:16 Integrated Voltage Measurement... 15:32:38 Voltage Offset Correction: v_off_ini = -0.000000857 V, v_off_fin = -0.000000674 V 15:32:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453234 Vs 15:32:38 Integrated Voltage Measurement... 15:33:01 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = -0.000001618 V 15:33:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433872 Vs 15:33:14 Temperature Measurement, Probe Number = 0, T = 20.299000 C 15:33:15 Temperature Measurement, Probe Number = 1, T = 20.156000 C 15:33:15 Temperature Measurement, Probe Number = 2, T = 20.197000 C 15:33:16 Temperature Measurement, Probe Number = 3, T = 20.215000 C 15:33:17 Temperature Measurement, Probe Number = 4, T = 20.179000 C 15:33:17 Temperature Measurement, Probe Number = 5, T = 20.118000 C 15:33:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.16 P3 = Bottom_DS_Module, Value = 20.20 P4 = Encode_Arm, Value = 20.21 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:33:17 Integrated Voltage Measurement... 15:33:40 Voltage Offset Correction: v_off_ini = -0.000001435 V, v_off_fin = 0.000000081 V 15:33:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158460312 Vs 15:33:40 Integrated Voltage Measurement... 15:34:03 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000002299 V 15:34:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424650 Vs 15:34:16 Temperature Measurement, Probe Number = 0, T = 20.288000 C 15:34:17 Temperature Measurement, Probe Number = 1, T = 20.152000 C 15:34:17 Temperature Measurement, Probe Number = 2, T = 20.191000 C 15:34:18 Temperature Measurement, Probe Number = 3, T = 20.215000 C 15:34:19 Temperature Measurement, Probe Number = 4, T = 20.178000 C 15:34:19 Temperature Measurement, Probe Number = 5, T = 20.118000 C 15:34:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 20.15 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.21 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:34:19 Integrated Voltage Measurement... 15:34:41 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = 0.000001699 V 15:34:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158440790 Vs 15:34:41 Integrated Voltage Measurement... 15:35:04 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000001552 V 15:35:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158428885 Vs 15:35:17 Temperature Measurement, Probe Number = 0, T = 20.295000 C 15:35:18 Temperature Measurement, Probe Number = 1, T = 20.153000 C 15:35:18 Temperature Measurement, Probe Number = 2, T = 20.192000 C 15:35:19 Temperature Measurement, Probe Number = 3, T = 20.216000 C 15:35:20 Temperature Measurement, Probe Number = 4, T = 20.179000 C 15:35:20 Temperature Measurement, Probe Number = 5, T = 20.119000 C 15:35:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.15 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.22 P5 = Bottom_Jaw, Value = 20.18 P6 = Top_Jaw, Value = 20.12 15:35:20 Integrated Voltage Measurement... 15:35:42 Voltage Offset Correction: v_off_ini = 0.000000088 V, v_off_fin = -0.000000849 V 15:35:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442154 Vs 15:35:43 Integrated Voltage Measurement... 15:36:05 Voltage Offset Correction: v_off_ini = 0.000003353 V, v_off_fin = -0.000001874 V 15:36:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158465712 Vs 16:32:19 Temperature Measurement, Probe Number = 0, T = 20.067000 C 16:32:19 Temperature Measurement, Probe Number = 1, T = 20.134000 C 16:32:20 Temperature Measurement, Probe Number = 2, T = 20.180000 C 16:32:21 Temperature Measurement, Probe Number = 3, T = 20.175000 C 16:32:21 Temperature Measurement, Probe Number = 4, T = 20.171000 C 16:32:22 Temperature Measurement, Probe Number = 5, T = 20.109000 C 16:32:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:32:22 Integrated Voltage Measurement... 16:32:44 Voltage Offset Correction: v_off_ini = -0.000000637 V, v_off_fin = -0.000002547 V 16:32:44 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158473897 Vs 16:32:44 Integrated Voltage Measurement... 16:33:06 Voltage Offset Correction: v_off_ini = -0.000002356 V, v_off_fin = -0.000002400 V 16:33:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440570 Vs 16:33:20 Temperature Measurement, Probe Number = 0, T = 20.072000 C 16:33:21 Temperature Measurement, Probe Number = 1, T = 20.131000 C 16:33:21 Temperature Measurement, Probe Number = 2, T = 20.181000 C 16:33:22 Temperature Measurement, Probe Number = 3, T = 20.176000 C 16:33:22 Temperature Measurement, Probe Number = 4, T = 20.170000 C 16:33:23 Temperature Measurement, Probe Number = 5, T = 20.106000 C 16:33:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.18 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:33:23 Integrated Voltage Measurement... 16:33:45 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = 0.000000732 V 16:33:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453123 Vs 16:33:45 Integrated Voltage Measurement... 16:34:08 Voltage Offset Correction: v_off_ini = 0.000000271 V, v_off_fin = -0.000001581 V 16:34:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158469164 Vs 16:34:21 Temperature Measurement, Probe Number = 0, T = 20.088000 C 16:34:22 Temperature Measurement, Probe Number = 1, T = 20.140000 C 16:34:22 Temperature Measurement, Probe Number = 2, T = 20.189000 C 16:34:23 Temperature Measurement, Probe Number = 3, T = 20.174000 C 16:34:24 Temperature Measurement, Probe Number = 4, T = 20.173000 C 16:34:24 Temperature Measurement, Probe Number = 5, T = 20.106000 C 16:34:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:34:24 Integrated Voltage Measurement... 16:34:46 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000001837 V 16:34:46 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158475741 Vs 16:34:46 Integrated Voltage Measurement... 16:35:09 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = -0.000000703 V 16:35:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158474334 Vs 16:35:22 Temperature Measurement, Probe Number = 0, T = 20.073000 C 16:35:23 Temperature Measurement, Probe Number = 1, T = 20.139000 C 16:35:23 Temperature Measurement, Probe Number = 2, T = 20.189000 C 16:35:24 Temperature Measurement, Probe Number = 3, T = 20.171000 C 16:35:25 Temperature Measurement, Probe Number = 4, T = 20.172000 C 16:35:25 Temperature Measurement, Probe Number = 5, T = 20.108000 C 16:35:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:35:25 Integrated Voltage Measurement... 16:35:47 Voltage Offset Correction: v_off_ini = -0.000002811 V, v_off_fin = -0.000000878 V 16:35:47 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158470816 Vs 16:35:47 Integrated Voltage Measurement... 16:36:09 Voltage Offset Correction: v_off_ini = -0.000000183 V, v_off_fin = -0.000001757 V 16:36:10 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158448047 Vs 16:36:23 Temperature Measurement, Probe Number = 0, T = 20.089000 C 16:36:24 Temperature Measurement, Probe Number = 1, T = 20.140000 C 16:36:24 Temperature Measurement, Probe Number = 2, T = 20.191000 C 16:36:25 Temperature Measurement, Probe Number = 3, T = 20.168000 C 16:36:25 Temperature Measurement, Probe Number = 4, T = 20.173000 C 16:36:26 Temperature Measurement, Probe Number = 5, T = 20.107000 C 16:36:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:36:26 Integrated Voltage Measurement... 16:36:48 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = -0.000001523 V 16:36:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158454715 Vs 16:36:48 Integrated Voltage Measurement... 16:37:11 Voltage Offset Correction: v_off_ini = -0.000004480 V, v_off_fin = -0.000002489 V 16:37:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158410506 Vs 16:37:24 Temperature Measurement, Probe Number = 0, T = 20.099000 C 16:37:25 Temperature Measurement, Probe Number = 1, T = 20.137000 C 16:37:26 Temperature Measurement, Probe Number = 2, T = 20.185000 C 16:37:26 Temperature Measurement, Probe Number = 3, T = 20.167000 C 16:37:27 Temperature Measurement, Probe Number = 4, T = 20.171000 C 16:37:27 Temperature Measurement, Probe Number = 5, T = 20.107000 C 16:37:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:37:27 Integrated Voltage Measurement... 16:37:50 Voltage Offset Correction: v_off_ini = -0.000001105 V, v_off_fin = -0.000000615 V 16:37:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158458295 Vs 16:37:50 Integrated Voltage Measurement... 16:38:12 Voltage Offset Correction: v_off_ini = -0.000000183 V, v_off_fin = -0.000002394 V 16:38:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432597 Vs 16:38:26 Temperature Measurement, Probe Number = 0, T = 20.102000 C 16:38:26 Temperature Measurement, Probe Number = 1, T = 20.136000 C 16:38:27 Temperature Measurement, Probe Number = 2, T = 20.190000 C 16:38:28 Temperature Measurement, Probe Number = 3, T = 20.162000 C 16:38:28 Temperature Measurement, Probe Number = 4, T = 20.172000 C 16:38:29 Temperature Measurement, Probe Number = 5, T = 20.105000 C 16:38:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.16 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:38:29 Integrated Voltage Measurement... 16:38:51 Voltage Offset Correction: v_off_ini = -0.000001493 V, v_off_fin = 0.000001010 V 16:38:51 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158457525 Vs 16:38:51 Integrated Voltage Measurement... 16:39:14 Voltage Offset Correction: v_off_ini = -0.000002848 V, v_off_fin = -0.000002284 V 16:39:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433692 Vs 16:39:28 Temperature Measurement, Probe Number = 0, T = 20.083000 C 16:39:28 Temperature Measurement, Probe Number = 1, T = 20.138000 C 16:39:29 Temperature Measurement, Probe Number = 2, T = 20.186000 C 16:39:30 Temperature Measurement, Probe Number = 3, T = 20.164000 C 16:39:30 Temperature Measurement, Probe Number = 4, T = 20.172000 C 16:39:31 Temperature Measurement, Probe Number = 5, T = 20.106000 C 16:39:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.16 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:39:31 Integrated Voltage Measurement... 16:39:53 Voltage Offset Correction: v_off_ini = -0.000002086 V, v_off_fin = -0.000004495 V 16:39:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158525758 Vs 16:39:53 Integrated Voltage Measurement... 16:40:15 Voltage Offset Correction: v_off_ini = 0.000000432 V, v_off_fin = -0.000001947 V 16:40:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158456259 Vs 16:40:29 Temperature Measurement, Probe Number = 0, T = 20.066000 C 16:40:29 Temperature Measurement, Probe Number = 1, T = 20.138000 C 16:40:30 Temperature Measurement, Probe Number = 2, T = 20.189000 C 16:40:31 Temperature Measurement, Probe Number = 3, T = 20.166000 C 16:40:31 Temperature Measurement, Probe Number = 4, T = 20.171000 C 16:40:32 Temperature Measurement, Probe Number = 5, T = 20.105000 C 16:40:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.17 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.11 16:40:32 Integrated Voltage Measurement... 16:40:54 Voltage Offset Correction: v_off_ini = -0.000002357 V, v_off_fin = 0.000003206 V 16:40:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158444385 Vs 16:40:54 Integrated Voltage Measurement... 16:41:18 Voltage Offset Correction: v_off_ini = -0.000002167 V, v_off_fin = -0.000002643 V 16:41:19 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158441713 Vs 16:41:32 Temperature Measurement, Probe Number = 0, T = 20.029000 C 16:41:33 Temperature Measurement, Probe Number = 1, T = 20.134000 C 16:41:33 Temperature Measurement, Probe Number = 2, T = 20.190000 C 16:41:34 Temperature Measurement, Probe Number = 3, T = 20.163000 C 16:41:34 Temperature Measurement, Probe Number = 4, T = 20.170000 C 16:41:35 Temperature Measurement, Probe Number = 5, T = 20.104000 C 16:41:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.16 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.10 16:41:35 Integrated Voltage Measurement... 16:41:57 Voltage Offset Correction: v_off_ini = -0.000000959 V, v_off_fin = -0.000000491 V 16:41:58 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158456885 Vs 16:41:58 Integrated Voltage Measurement... 16:42:20 Voltage Offset Correction: v_off_ini = 0.000000176 V, v_off_fin = -0.000002013 V 16:42:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449480 Vs 17:38:34 Temperature Measurement, Probe Number = 0, T = 20.087000 C 17:38:34 Temperature Measurement, Probe Number = 1, T = 20.135000 C 17:38:35 Temperature Measurement, Probe Number = 2, T = 20.185000 C 17:38:35 Temperature Measurement, Probe Number = 3, T = 20.153000 C 17:38:36 Temperature Measurement, Probe Number = 4, T = 20.165000 C 17:38:37 Temperature Measurement, Probe Number = 5, T = 20.102000 C 17:38:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:38:37 Integrated Voltage Measurement... 17:38:59 Voltage Offset Correction: v_off_ini = -0.000001435 V, v_off_fin = -0.000007936 V 17:38:59 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158575956 Vs 17:38:59 Integrated Voltage Measurement... 17:39:21 Voltage Offset Correction: v_off_ini = 0.000000044 V, v_off_fin = -0.000002416 V 17:39:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451276 Vs 17:39:35 Temperature Measurement, Probe Number = 0, T = 20.102000 C 17:39:35 Temperature Measurement, Probe Number = 1, T = 20.136000 C 17:39:36 Temperature Measurement, Probe Number = 2, T = 20.186000 C 17:39:36 Temperature Measurement, Probe Number = 3, T = 20.150000 C 17:39:37 Temperature Measurement, Probe Number = 4, T = 20.164000 C 17:39:38 Temperature Measurement, Probe Number = 5, T = 20.099000 C 17:39:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:39:38 Integrated Voltage Measurement... 17:40:00 Voltage Offset Correction: v_off_ini = -0.000001977 V, v_off_fin = -0.000000915 V 17:40:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158497191 Vs 17:40:00 Integrated Voltage Measurement... 17:40:22 Voltage Offset Correction: v_off_ini = 0.000003280 V, v_off_fin = -0.000003660 V 17:40:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158497272 Vs 17:40:36 Temperature Measurement, Probe Number = 0, T = 20.092000 C 17:40:37 Temperature Measurement, Probe Number = 1, T = 20.135000 C 17:40:37 Temperature Measurement, Probe Number = 2, T = 20.187000 C 17:40:38 Temperature Measurement, Probe Number = 3, T = 20.151000 C 17:40:38 Temperature Measurement, Probe Number = 4, T = 20.165000 C 17:40:39 Temperature Measurement, Probe Number = 5, T = 20.100000 C 17:40:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:40:39 Integrated Voltage Measurement... 17:41:01 Voltage Offset Correction: v_off_ini = -0.000001084 V, v_off_fin = 0.000000674 V 17:41:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158472479 Vs 17:41:01 Integrated Voltage Measurement... 17:41:23 Voltage Offset Correction: v_off_ini = 0.000001120 V, v_off_fin = -0.000002445 V 17:41:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468081 Vs 17:41:37 Temperature Measurement, Probe Number = 0, T = 20.095000 C 17:41:38 Temperature Measurement, Probe Number = 1, T = 20.136000 C 17:41:38 Temperature Measurement, Probe Number = 2, T = 20.186000 C 17:41:39 Temperature Measurement, Probe Number = 3, T = 20.149000 C 17:41:39 Temperature Measurement, Probe Number = 4, T = 20.164000 C 17:41:40 Temperature Measurement, Probe Number = 5, T = 20.098000 C 17:41:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:41:40 Integrated Voltage Measurement... 17:42:02 Voltage Offset Correction: v_off_ini = -0.000000110 V, v_off_fin = 0.000000703 V 17:42:02 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158467023 Vs 17:42:02 Integrated Voltage Measurement... 17:42:25 Voltage Offset Correction: v_off_ini = -0.000000746 V, v_off_fin = -0.000001193 V 17:42:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158467634 Vs 17:42:38 Temperature Measurement, Probe Number = 0, T = 20.086000 C 17:42:39 Temperature Measurement, Probe Number = 1, T = 20.134000 C 17:42:39 Temperature Measurement, Probe Number = 2, T = 20.181000 C 17:42:40 Temperature Measurement, Probe Number = 3, T = 20.145000 C 17:42:41 Temperature Measurement, Probe Number = 4, T = 20.165000 C 17:42:41 Temperature Measurement, Probe Number = 5, T = 20.100000 C 17:42:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:42:41 Integrated Voltage Measurement... 17:43:03 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = 0.000000403 V 17:43:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158458634 Vs 17:43:03 Integrated Voltage Measurement... 17:43:26 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000002196 V 17:43:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158459538 Vs 17:43:39 Temperature Measurement, Probe Number = 0, T = 20.065000 C 17:43:40 Temperature Measurement, Probe Number = 1, T = 20.132000 C 17:43:40 Temperature Measurement, Probe Number = 2, T = 20.182000 C 17:43:41 Temperature Measurement, Probe Number = 3, T = 20.149000 C 17:43:42 Temperature Measurement, Probe Number = 4, T = 20.165000 C 17:43:42 Temperature Measurement, Probe Number = 5, T = 20.099000 C 17:43:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:43:42 Integrated Voltage Measurement... 17:44:04 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = -0.000001413 V 17:44:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158468085 Vs 17:44:05 Integrated Voltage Measurement... 17:44:27 Voltage Offset Correction: v_off_ini = 0.000000278 V, v_off_fin = -0.000000198 V 17:44:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158471293 Vs 17:44:40 Temperature Measurement, Probe Number = 0, T = 20.093000 C 17:44:41 Temperature Measurement, Probe Number = 1, T = 20.139000 C 17:44:42 Temperature Measurement, Probe Number = 2, T = 20.187000 C 17:44:42 Temperature Measurement, Probe Number = 3, T = 20.153000 C 17:44:43 Temperature Measurement, Probe Number = 4, T = 20.166000 C 17:44:43 Temperature Measurement, Probe Number = 5, T = 20.101000 C 17:44:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.10 17:44:43 Integrated Voltage Measurement... 17:45:06 Voltage Offset Correction: v_off_ini = -0.000002320 V, v_off_fin = -0.000003184 V 17:45:06 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158494974 Vs 17:45:06 Integrated Voltage Measurement... 17:45:28 Voltage Offset Correction: v_off_ini = -0.000002035 V, v_off_fin = -0.000001793 V 17:45:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442718 Vs 17:45:41 Temperature Measurement, Probe Number = 0, T = 20.097000 C 17:45:42 Temperature Measurement, Probe Number = 1, T = 20.134000 C 17:45:43 Temperature Measurement, Probe Number = 2, T = 20.184000 C 17:45:43 Temperature Measurement, Probe Number = 3, T = 20.154000 C 17:45:44 Temperature Measurement, Probe Number = 4, T = 20.165000 C 17:45:44 Temperature Measurement, Probe Number = 5, T = 20.100000 C 17:45:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.10 17:45:44 Integrated Voltage Measurement... 17:46:07 Voltage Offset Correction: v_off_ini = -0.000001662 V, v_off_fin = -0.000002709 V 17:46:07 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158491773 Vs 17:46:07 Integrated Voltage Measurement... 17:46:29 Voltage Offset Correction: v_off_ini = -0.000001186 V, v_off_fin = -0.000001632 V 17:46:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158453089 Vs 17:46:43 Temperature Measurement, Probe Number = 0, T = 20.095000 C 17:46:44 Temperature Measurement, Probe Number = 1, T = 20.133000 C 17:46:44 Temperature Measurement, Probe Number = 2, T = 20.187000 C 17:46:45 Temperature Measurement, Probe Number = 3, T = 20.155000 C 17:46:45 Temperature Measurement, Probe Number = 4, T = 20.166000 C 17:46:46 Temperature Measurement, Probe Number = 5, T = 20.099000 C 17:46:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.16 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.10 17:46:46 Integrated Voltage Measurement... 17:47:08 Voltage Offset Correction: v_off_ini = -0.000001669 V, v_off_fin = 0.000000659 V 17:47:09 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158475152 Vs 17:47:09 Integrated Voltage Measurement... 17:47:31 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000002005 V 17:47:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158459279 Vs 17:47:45 Temperature Measurement, Probe Number = 0, T = 20.117000 C 17:47:46 Temperature Measurement, Probe Number = 1, T = 20.135000 C 17:47:46 Temperature Measurement, Probe Number = 2, T = 20.189000 C 17:47:47 Temperature Measurement, Probe Number = 3, T = 20.152000 C 17:47:48 Temperature Measurement, Probe Number = 4, T = 20.166000 C 17:47:48 Temperature Measurement, Probe Number = 5, T = 20.099000 C 17:47:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.14 P3 = Bottom_DS_Module, Value = 20.19 P4 = Encode_Arm, Value = 20.15 P5 = Bottom_Jaw, Value = 20.17 P6 = Top_Jaw, Value = 20.10 17:47:48 Integrated Voltage Measurement... 17:48:10 Voltage Offset Correction: v_off_ini = -0.000001113 V, v_off_fin = -0.000000059 V 17:48:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158475145 Vs 17:48:10 Integrated Voltage Measurement... 17:48:33 Voltage Offset Correction: v_off_ini = -0.000000293 V, v_off_fin = -0.000001720 V 17:48:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158462465 Vs 18:44:46 Temperature Measurement, Probe Number = 0, T = 20.048000 C 18:44:47 Temperature Measurement, Probe Number = 1, T = 20.122000 C 18:44:48 Temperature Measurement, Probe Number = 2, T = 20.173000 C 18:44:48 Temperature Measurement, Probe Number = 3, T = 20.134000 C 18:44:49 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:44:49 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:44:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:44:49 Integrated Voltage Measurement... 18:45:12 Voltage Offset Correction: v_off_ini = -0.000000798 V, v_off_fin = -0.000000512 V 18:45:12 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158489289 Vs 18:45:12 Integrated Voltage Measurement... 18:45:34 Voltage Offset Correction: v_off_ini = -0.000001683 V, v_off_fin = -0.000002041 V 18:45:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413723 Vs 18:45:48 Temperature Measurement, Probe Number = 0, T = 20.035000 C 18:45:49 Temperature Measurement, Probe Number = 1, T = 20.126000 C 18:45:49 Temperature Measurement, Probe Number = 2, T = 20.177000 C 18:45:50 Temperature Measurement, Probe Number = 3, T = 20.136000 C 18:45:50 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:45:51 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:45:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:45:51 Integrated Voltage Measurement... 18:46:13 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = 0.000000644 V 18:46:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158457923 Vs 18:46:14 Integrated Voltage Measurement... 18:46:36 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000002547 V 18:46:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438996 Vs 18:46:50 Temperature Measurement, Probe Number = 0, T = 20.035000 C 18:46:50 Temperature Measurement, Probe Number = 1, T = 20.126000 C 18:46:51 Temperature Measurement, Probe Number = 2, T = 20.177000 C 18:46:52 Temperature Measurement, Probe Number = 3, T = 20.137000 C 18:46:52 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:46:53 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:46:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:46:53 Integrated Voltage Measurement... 18:47:15 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000001698 V 18:47:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158462294 Vs 18:47:15 Integrated Voltage Measurement... 18:47:37 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000002693 V 18:47:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438951 Vs 18:47:51 Temperature Measurement, Probe Number = 0, T = 20.020000 C 18:47:51 Temperature Measurement, Probe Number = 1, T = 20.125000 C 18:47:52 Temperature Measurement, Probe Number = 2, T = 20.173000 C 18:47:53 Temperature Measurement, Probe Number = 3, T = 20.135000 C 18:47:53 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:47:54 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:47:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:47:54 Integrated Voltage Measurement... 18:48:16 Voltage Offset Correction: v_off_ini = -0.000001669 V, v_off_fin = -0.000000263 V 18:48:16 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462616 Vs 18:48:16 Integrated Voltage Measurement... 18:48:38 Voltage Offset Correction: v_off_ini = -0.000001837 V, v_off_fin = -0.000001215 V 18:48:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427953 Vs 18:48:52 Temperature Measurement, Probe Number = 0, T = 20.024000 C 18:48:53 Temperature Measurement, Probe Number = 1, T = 20.125000 C 18:48:53 Temperature Measurement, Probe Number = 2, T = 20.178000 C 18:48:54 Temperature Measurement, Probe Number = 3, T = 20.132000 C 18:48:54 Temperature Measurement, Probe Number = 4, T = 20.154000 C 18:48:55 Temperature Measurement, Probe Number = 5, T = 20.090000 C 18:48:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 18:48:55 Integrated Voltage Measurement... 18:49:17 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000001127 V 18:49:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158453063 Vs 18:49:17 Integrated Voltage Measurement... 18:49:39 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = -0.000001903 V 18:49:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440290 Vs 18:49:53 Temperature Measurement, Probe Number = 0, T = 20.024000 C 18:49:53 Temperature Measurement, Probe Number = 1, T = 20.122000 C 18:49:54 Temperature Measurement, Probe Number = 2, T = 20.173000 C 18:49:55 Temperature Measurement, Probe Number = 3, T = 20.133000 C 18:49:55 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:49:56 Temperature Measurement, Probe Number = 5, T = 20.090000 C 18:49:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:49:56 Integrated Voltage Measurement... 18:50:18 Voltage Offset Correction: v_off_ini = -0.000002371 V, v_off_fin = -0.000001083 V 18:50:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446643 Vs 18:50:18 Integrated Voltage Measurement... 18:50:41 Voltage Offset Correction: v_off_ini = 0.000001230 V, v_off_fin = -0.000001771 V 18:50:41 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158442961 Vs 18:50:54 Temperature Measurement, Probe Number = 0, T = 20.059000 C 18:50:55 Temperature Measurement, Probe Number = 1, T = 20.126000 C 18:50:55 Temperature Measurement, Probe Number = 2, T = 20.170000 C 18:50:56 Temperature Measurement, Probe Number = 3, T = 20.133000 C 18:50:57 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:50:57 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:50:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:50:57 Integrated Voltage Measurement... 18:51:19 Voltage Offset Correction: v_off_ini = -0.000002722 V, v_off_fin = 0.000000863 V 18:51:20 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158453105 Vs 18:51:20 Integrated Voltage Measurement... 18:51:42 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000002079 V 18:51:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439943 Vs 18:51:56 Temperature Measurement, Probe Number = 0, T = 20.086000 C 18:51:56 Temperature Measurement, Probe Number = 1, T = 20.124000 C 18:51:57 Temperature Measurement, Probe Number = 2, T = 20.171000 C 18:51:57 Temperature Measurement, Probe Number = 3, T = 20.134000 C 18:51:58 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:51:59 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:51:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:51:59 Integrated Voltage Measurement... 18:52:21 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = -0.000002232 V 18:52:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455204 Vs 18:52:21 Integrated Voltage Measurement... 18:52:44 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000003981 V 18:52:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407346 Vs 18:52:57 Temperature Measurement, Probe Number = 0, T = 20.078000 C 18:52:58 Temperature Measurement, Probe Number = 1, T = 20.127000 C 18:52:58 Temperature Measurement, Probe Number = 2, T = 20.175000 C 18:52:59 Temperature Measurement, Probe Number = 3, T = 20.135000 C 18:53:00 Temperature Measurement, Probe Number = 4, T = 20.155000 C 18:53:00 Temperature Measurement, Probe Number = 5, T = 20.091000 C 18:53:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.13 P3 = Bottom_DS_Module, Value = 20.18 P4 = Encode_Arm, Value = 20.14 P5 = Bottom_Jaw, Value = 20.16 P6 = Top_Jaw, Value = 20.09 18:53:00 Integrated Voltage Measurement... 18:53:22 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000000124 V 18:53:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453699 Vs 18:53:22 Integrated Voltage Measurement... 18:53:45 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000003125 V 18:53:45 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158428536 Vs 18:53:59 Temperature Measurement, Probe Number = 0, T = 20.032000 C 18:53:59 Temperature Measurement, Probe Number = 1, T = 20.118000 C 18:54:00 Temperature Measurement, Probe Number = 2, T = 20.167000 C 18:54:01 Temperature Measurement, Probe Number = 3, T = 20.131000 C 18:54:01 Temperature Measurement, Probe Number = 4, T = 20.154000 C 18:54:02 Temperature Measurement, Probe Number = 5, T = 20.089000 C 18:54:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.17 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.15 P6 = Top_Jaw, Value = 20.09 18:54:02 Integrated Voltage Measurement... 18:54:24 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000007 V 18:54:24 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158428307 Vs 18:54:24 Integrated Voltage Measurement... 18:54:47 Voltage Offset Correction: v_off_ini = 0.000005283 V, v_off_fin = -0.000003139 V 18:54:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158486687 Vs 19:51:01 Temperature Measurement, Probe Number = 0, T = 20.035000 C 19:51:02 Temperature Measurement, Probe Number = 1, T = 20.115000 C 19:51:02 Temperature Measurement, Probe Number = 2, T = 20.161000 C 19:51:03 Temperature Measurement, Probe Number = 3, T = 20.124000 C 19:51:04 Temperature Measurement, Probe Number = 4, T = 20.145000 C 19:51:04 Temperature Measurement, Probe Number = 5, T = 20.080000 C 19:51:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:51:04 Integrated Voltage Measurement... 19:51:26 Voltage Offset Correction: v_off_ini = -0.000000278 V, v_off_fin = 0.000000556 V 19:51:27 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158450459 Vs 19:51:27 Integrated Voltage Measurement... 19:51:49 Voltage Offset Correction: v_off_ini = -0.000000835 V, v_off_fin = -0.000003090 V 19:51:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384576 Vs 19:52:03 Temperature Measurement, Probe Number = 0, T = 20.037000 C 19:52:03 Temperature Measurement, Probe Number = 1, T = 20.114000 C 19:52:04 Temperature Measurement, Probe Number = 2, T = 20.161000 C 19:52:05 Temperature Measurement, Probe Number = 3, T = 20.122000 C 19:52:05 Temperature Measurement, Probe Number = 4, T = 20.143000 C 19:52:06 Temperature Measurement, Probe Number = 5, T = 20.080000 C 19:52:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:52:06 Integrated Voltage Measurement... 19:52:28 Voltage Offset Correction: v_off_ini = -0.000002203 V, v_off_fin = -0.000002342 V 19:52:28 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158424540 Vs 19:52:28 Integrated Voltage Measurement... 19:52:50 Voltage Offset Correction: v_off_ini = 0.000002840 V, v_off_fin = -0.000001610 V 19:52:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427884 Vs 19:53:04 Temperature Measurement, Probe Number = 0, T = 20.043000 C 19:53:05 Temperature Measurement, Probe Number = 1, T = 20.114000 C 19:53:05 Temperature Measurement, Probe Number = 2, T = 20.162000 C 19:53:06 Temperature Measurement, Probe Number = 3, T = 20.121000 C 19:53:06 Temperature Measurement, Probe Number = 4, T = 20.143000 C 19:53:07 Temperature Measurement, Probe Number = 5, T = 20.080000 C 19:53:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:53:07 Integrated Voltage Measurement... 19:53:29 Voltage Offset Correction: v_off_ini = -0.000002173 V, v_off_fin = 0.000000746 V 19:53:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395968 Vs 19:53:30 Integrated Voltage Measurement... 19:53:52 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000001947 V 19:53:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385631 Vs 19:54:06 Temperature Measurement, Probe Number = 0, T = 20.051000 C 19:54:06 Temperature Measurement, Probe Number = 1, T = 20.115000 C 19:54:07 Temperature Measurement, Probe Number = 2, T = 20.161000 C 19:54:07 Temperature Measurement, Probe Number = 3, T = 20.123000 C 19:54:08 Temperature Measurement, Probe Number = 4, T = 20.143000 C 19:54:09 Temperature Measurement, Probe Number = 5, T = 20.079000 C 19:54:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:54:09 Integrated Voltage Measurement... 19:54:32 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000001675 V 19:54:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158414818 Vs 19:54:32 Integrated Voltage Measurement... 19:54:54 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000002167 V 19:54:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383480 Vs 19:55:08 Temperature Measurement, Probe Number = 0, T = 20.016000 C 19:55:08 Temperature Measurement, Probe Number = 1, T = 20.113000 C 19:55:09 Temperature Measurement, Probe Number = 2, T = 20.159000 C 19:55:09 Temperature Measurement, Probe Number = 3, T = 20.121000 C 19:55:10 Temperature Measurement, Probe Number = 4, T = 20.141000 C 19:55:11 Temperature Measurement, Probe Number = 5, T = 20.079000 C 19:55:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:55:11 Integrated Voltage Measurement... 19:55:33 Voltage Offset Correction: v_off_ini = -0.000002670 V, v_off_fin = -0.000000980 V 19:55:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437213 Vs 19:55:33 Integrated Voltage Measurement... 19:55:55 Voltage Offset Correction: v_off_ini = 0.000000724 V, v_off_fin = -0.000002107 V 19:55:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404539 Vs 19:56:09 Temperature Measurement, Probe Number = 0, T = 20.004000 C 19:56:09 Temperature Measurement, Probe Number = 1, T = 20.111000 C 19:56:10 Temperature Measurement, Probe Number = 2, T = 20.160000 C 19:56:11 Temperature Measurement, Probe Number = 3, T = 20.121000 C 19:56:11 Temperature Measurement, Probe Number = 4, T = 20.141000 C 19:56:12 Temperature Measurement, Probe Number = 5, T = 20.079000 C 19:56:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:56:12 Integrated Voltage Measurement... 19:56:34 Voltage Offset Correction: v_off_ini = -0.000001097 V, v_off_fin = 0.000001866 V 19:56:34 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158402495 Vs 19:56:34 Integrated Voltage Measurement... 19:56:56 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001500 V 19:56:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399955 Vs 19:57:10 Temperature Measurement, Probe Number = 0, T = 20.006000 C 19:57:10 Temperature Measurement, Probe Number = 1, T = 20.112000 C 19:57:11 Temperature Measurement, Probe Number = 2, T = 20.160000 C 19:57:12 Temperature Measurement, Probe Number = 3, T = 20.121000 C 19:57:12 Temperature Measurement, Probe Number = 4, T = 20.142000 C 19:57:13 Temperature Measurement, Probe Number = 5, T = 20.079000 C 19:57:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:57:13 Integrated Voltage Measurement... 19:57:35 Voltage Offset Correction: v_off_ini = -0.000002238 V, v_off_fin = -0.000001265 V 19:57:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400083 Vs 19:57:35 Integrated Voltage Measurement... 19:57:57 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000002253 V 19:57:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376045 Vs 19:58:11 Temperature Measurement, Probe Number = 0, T = 20.008000 C 19:58:11 Temperature Measurement, Probe Number = 1, T = 20.112000 C 19:58:12 Temperature Measurement, Probe Number = 2, T = 20.159000 C 19:58:13 Temperature Measurement, Probe Number = 3, T = 20.123000 C 19:58:13 Temperature Measurement, Probe Number = 4, T = 20.142000 C 19:58:14 Temperature Measurement, Probe Number = 5, T = 20.078000 C 19:58:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:58:14 Integrated Voltage Measurement... 19:58:36 Voltage Offset Correction: v_off_ini = -0.000000307 V, v_off_fin = 0.000000702 V 19:58:36 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158391970 Vs 19:58:36 Integrated Voltage Measurement... 19:58:59 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000002135 V 19:58:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158375616 Vs 19:59:12 Temperature Measurement, Probe Number = 0, T = 20.007000 C 19:59:13 Temperature Measurement, Probe Number = 1, T = 20.112000 C 19:59:13 Temperature Measurement, Probe Number = 2, T = 20.157000 C 19:59:14 Temperature Measurement, Probe Number = 3, T = 20.126000 C 19:59:15 Temperature Measurement, Probe Number = 4, T = 20.139000 C 19:59:15 Temperature Measurement, Probe Number = 5, T = 20.077000 C 19:59:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.13 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 19:59:15 Integrated Voltage Measurement... 19:59:37 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000000161 V 19:59:38 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158403193 Vs 19:59:38 Integrated Voltage Measurement... 20:00:00 Voltage Offset Correction: v_off_ini = 0.000000278 V, v_off_fin = -0.000001426 V 20:00:00 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158391949 Vs 20:00:13 Temperature Measurement, Probe Number = 0, T = 20.000000 C 20:00:14 Temperature Measurement, Probe Number = 1, T = 20.110000 C 20:00:14 Temperature Measurement, Probe Number = 2, T = 20.156000 C 20:00:15 Temperature Measurement, Probe Number = 3, T = 20.124000 C 20:00:16 Temperature Measurement, Probe Number = 4, T = 20.139000 C 20:00:16 Temperature Measurement, Probe Number = 5, T = 20.077000 C 20:00:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 20:00:16 Integrated Voltage Measurement... 20:00:38 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000001821 V 20:00:38 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158412541 Vs 20:00:38 Integrated Voltage Measurement... 20:01:01 Voltage Offset Correction: v_off_ini = -0.000000965 V, v_off_fin = -0.000002749 V 20:01:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158377625 Vs 20:57:14 Temperature Measurement, Probe Number = 0, T = 20.128000 C 20:57:15 Temperature Measurement, Probe Number = 1, T = 20.116000 C 20:57:16 Temperature Measurement, Probe Number = 2, T = 20.157000 C 20:57:16 Temperature Measurement, Probe Number = 3, T = 20.123000 C 20:57:17 Temperature Measurement, Probe Number = 4, T = 20.140000 C 20:57:17 Temperature Measurement, Probe Number = 5, T = 20.079000 C 20:57:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 20:57:17 Integrated Voltage Measurement... 20:57:40 Voltage Offset Correction: v_off_ini = -0.000000724 V, v_off_fin = 0.000002399 V 20:57:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158425630 Vs 20:57:40 Integrated Voltage Measurement... 20:58:02 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = -0.000001566 V 20:58:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383639 Vs 20:58:16 Temperature Measurement, Probe Number = 0, T = 20.182000 C 20:58:16 Temperature Measurement, Probe Number = 1, T = 20.116000 C 20:58:17 Temperature Measurement, Probe Number = 2, T = 20.159000 C 20:58:18 Temperature Measurement, Probe Number = 3, T = 20.123000 C 20:58:18 Temperature Measurement, Probe Number = 4, T = 20.140000 C 20:58:19 Temperature Measurement, Probe Number = 5, T = 20.078000 C 20:58:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 20:58:19 Integrated Voltage Measurement... 20:58:41 Voltage Offset Correction: v_off_ini = -0.000000124 V, v_off_fin = -0.000000746 V 20:58:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158396192 Vs 20:58:41 Integrated Voltage Measurement... 20:59:03 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000002999 V 20:59:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396076 Vs 20:59:17 Temperature Measurement, Probe Number = 0, T = 20.184000 C 20:59:17 Temperature Measurement, Probe Number = 1, T = 20.119000 C 20:59:18 Temperature Measurement, Probe Number = 2, T = 20.161000 C 20:59:19 Temperature Measurement, Probe Number = 3, T = 20.124000 C 20:59:19 Temperature Measurement, Probe Number = 4, T = 20.141000 C 20:59:20 Temperature Measurement, Probe Number = 5, T = 20.079000 C 20:59:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 20:59:20 Integrated Voltage Measurement... 20:59:42 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000000475 V 20:59:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158398243 Vs 20:59:42 Integrated Voltage Measurement... 21:00:05 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = -0.000001587 V 21:00:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367914 Vs 21:00:18 Temperature Measurement, Probe Number = 0, T = 20.185000 C 21:00:19 Temperature Measurement, Probe Number = 1, T = 20.114000 C 21:00:19 Temperature Measurement, Probe Number = 2, T = 20.159000 C 21:00:20 Temperature Measurement, Probe Number = 3, T = 20.123000 C 21:00:21 Temperature Measurement, Probe Number = 4, T = 20.140000 C 21:00:21 Temperature Measurement, Probe Number = 5, T = 20.077000 C 21:00:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:00:21 Integrated Voltage Measurement... 21:00:43 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = 0.000001317 V 21:00:43 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158386569 Vs 21:00:43 Integrated Voltage Measurement... 21:01:06 Voltage Offset Correction: v_off_ini = -0.000001243 V, v_off_fin = -0.000002224 V 21:01:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383886 Vs 21:01:20 Temperature Measurement, Probe Number = 0, T = 20.165000 C 21:01:20 Temperature Measurement, Probe Number = 1, T = 20.116000 C 21:01:21 Temperature Measurement, Probe Number = 2, T = 20.162000 C 21:01:21 Temperature Measurement, Probe Number = 3, T = 20.123000 C 21:01:22 Temperature Measurement, Probe Number = 4, T = 20.141000 C 21:01:23 Temperature Measurement, Probe Number = 5, T = 20.078000 C 21:01:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:01:23 Integrated Voltage Measurement... 21:01:45 Voltage Offset Correction: v_off_ini = -0.000000826 V, v_off_fin = -0.000000263 V 21:01:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402527 Vs 21:01:45 Integrated Voltage Measurement... 21:02:07 Voltage Offset Correction: v_off_ini = -0.000000095 V, v_off_fin = -0.000002742 V 21:02:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372151 Vs 21:02:21 Temperature Measurement, Probe Number = 0, T = 20.142000 C 21:02:21 Temperature Measurement, Probe Number = 1, T = 20.115000 C 21:02:22 Temperature Measurement, Probe Number = 2, T = 20.162000 C 21:02:22 Temperature Measurement, Probe Number = 3, T = 20.123000 C 21:02:23 Temperature Measurement, Probe Number = 4, T = 20.141000 C 21:02:24 Temperature Measurement, Probe Number = 5, T = 20.079000 C 21:02:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:02:24 Integrated Voltage Measurement... 21:02:46 Voltage Offset Correction: v_off_ini = -0.000002954 V, v_off_fin = -0.000001272 V 21:02:46 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158434431 Vs 21:02:46 Integrated Voltage Measurement... 21:03:08 Voltage Offset Correction: v_off_ini = -0.000000534 V, v_off_fin = -0.000002955 V 21:03:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384105 Vs 21:03:22 Temperature Measurement, Probe Number = 0, T = 20.119000 C 21:03:22 Temperature Measurement, Probe Number = 1, T = 20.114000 C 21:03:23 Temperature Measurement, Probe Number = 2, T = 20.160000 C 21:03:24 Temperature Measurement, Probe Number = 3, T = 20.122000 C 21:03:24 Temperature Measurement, Probe Number = 4, T = 20.140000 C 21:03:25 Temperature Measurement, Probe Number = 5, T = 20.078000 C 21:03:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:03:25 Integrated Voltage Measurement... 21:03:47 Voltage Offset Correction: v_off_ini = -0.000002633 V, v_off_fin = -0.000000746 V 21:03:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158395386 Vs 21:03:47 Integrated Voltage Measurement... 21:04:09 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000001909 V 21:04:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394457 Vs 21:04:23 Temperature Measurement, Probe Number = 0, T = 20.130000 C 21:04:24 Temperature Measurement, Probe Number = 1, T = 20.114000 C 21:04:24 Temperature Measurement, Probe Number = 2, T = 20.158000 C 21:04:25 Temperature Measurement, Probe Number = 3, T = 20.123000 C 21:04:25 Temperature Measurement, Probe Number = 4, T = 20.140000 C 21:04:26 Temperature Measurement, Probe Number = 5, T = 20.077000 C 21:04:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:04:26 Integrated Voltage Measurement... 21:04:48 Voltage Offset Correction: v_off_ini = -0.000000929 V, v_off_fin = -0.000002575 V 21:04:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158445690 Vs 21:04:49 Integrated Voltage Measurement... 21:05:11 Voltage Offset Correction: v_off_ini = -0.000001382 V, v_off_fin = -0.000001741 V 21:05:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388020 Vs 21:05:24 Temperature Measurement, Probe Number = 0, T = 20.136000 C 21:05:25 Temperature Measurement, Probe Number = 1, T = 20.113000 C 21:05:26 Temperature Measurement, Probe Number = 2, T = 20.160000 C 21:05:26 Temperature Measurement, Probe Number = 3, T = 20.125000 C 21:05:27 Temperature Measurement, Probe Number = 4, T = 20.139000 C 21:05:27 Temperature Measurement, Probe Number = 5, T = 20.077000 C 21:05:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:05:27 Integrated Voltage Measurement... 21:05:50 Voltage Offset Correction: v_off_ini = -0.000001858 V, v_off_fin = -0.000000051 V 21:05:50 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158408490 Vs 21:05:50 Integrated Voltage Measurement... 21:06:12 Voltage Offset Correction: v_off_ini = -0.000000607 V, v_off_fin = -0.000003658 V 21:06:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158360498 Vs 21:06:25 Temperature Measurement, Probe Number = 0, T = 20.159000 C 21:06:26 Temperature Measurement, Probe Number = 1, T = 20.112000 C 21:06:27 Temperature Measurement, Probe Number = 2, T = 20.158000 C 21:06:27 Temperature Measurement, Probe Number = 3, T = 20.125000 C 21:06:28 Temperature Measurement, Probe Number = 4, T = 20.139000 C 21:06:28 Temperature Measurement, Probe Number = 5, T = 20.077000 C 21:06:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.08 21:06:28 Integrated Voltage Measurement... 21:06:51 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000001639 V 21:06:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158415115 Vs 21:06:51 Integrated Voltage Measurement... 21:07:13 Voltage Offset Correction: v_off_ini = -0.000000958 V, v_off_fin = -0.000003951 V 21:07:13 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158372852 Vs 22:03:26 Temperature Measurement, Probe Number = 0, T = 20.122000 C 22:03:27 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:03:27 Temperature Measurement, Probe Number = 2, T = 20.151000 C 22:03:28 Temperature Measurement, Probe Number = 3, T = 20.116000 C 22:03:29 Temperature Measurement, Probe Number = 4, T = 20.134000 C 22:03:29 Temperature Measurement, Probe Number = 5, T = 20.073000 C 22:03:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 22:03:29 Integrated Voltage Measurement... 22:03:51 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000000790 V 22:03:52 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158449559 Vs 22:03:52 Integrated Voltage Measurement... 22:04:14 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001990 V 22:04:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386130 Vs 22:04:28 Temperature Measurement, Probe Number = 0, T = 20.106000 C 22:04:28 Temperature Measurement, Probe Number = 1, T = 20.109000 C 22:04:29 Temperature Measurement, Probe Number = 2, T = 20.151000 C 22:04:30 Temperature Measurement, Probe Number = 3, T = 20.115000 C 22:04:30 Temperature Measurement, Probe Number = 4, T = 20.134000 C 22:04:31 Temperature Measurement, Probe Number = 5, T = 20.072000 C 22:04:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 22:04:31 Integrated Voltage Measurement... 22:04:53 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = 0.000000907 V 22:04:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382658 Vs 22:04:53 Integrated Voltage Measurement... 22:05:15 Voltage Offset Correction: v_off_ini = 0.000000915 V, v_off_fin = -0.000003424 V 22:05:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404461 Vs 22:05:29 Temperature Measurement, Probe Number = 0, T = 20.088000 C 22:05:30 Temperature Measurement, Probe Number = 1, T = 20.115000 C 22:05:30 Temperature Measurement, Probe Number = 2, T = 20.156000 C 22:05:31 Temperature Measurement, Probe Number = 3, T = 20.112000 C 22:05:31 Temperature Measurement, Probe Number = 4, T = 20.136000 C 22:05:32 Temperature Measurement, Probe Number = 5, T = 20.074000 C 22:05:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:05:32 Integrated Voltage Measurement... 22:05:54 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000000907 V 22:05:54 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158425360 Vs 22:05:54 Integrated Voltage Measurement... 22:06:17 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000003687 V 22:06:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373570 Vs 22:06:30 Temperature Measurement, Probe Number = 0, T = 20.098000 C 22:06:31 Temperature Measurement, Probe Number = 1, T = 20.114000 C 22:06:32 Temperature Measurement, Probe Number = 2, T = 20.158000 C 22:06:32 Temperature Measurement, Probe Number = 3, T = 20.115000 C 22:06:33 Temperature Measurement, Probe Number = 4, T = 20.135000 C 22:06:33 Temperature Measurement, Probe Number = 5, T = 20.074000 C 22:06:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:06:33 Integrated Voltage Measurement... 22:06:56 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000001287 V 22:06:56 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158408222 Vs 22:06:56 Integrated Voltage Measurement... 22:07:18 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000003372 V 22:07:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158408068 Vs 22:07:32 Temperature Measurement, Probe Number = 0, T = 20.128000 C 22:07:33 Temperature Measurement, Probe Number = 1, T = 20.112000 C 22:07:33 Temperature Measurement, Probe Number = 2, T = 20.158000 C 22:07:34 Temperature Measurement, Probe Number = 3, T = 20.114000 C 22:07:35 Temperature Measurement, Probe Number = 4, T = 20.135000 C 22:07:35 Temperature Measurement, Probe Number = 5, T = 20.074000 C 22:07:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:07:35 Integrated Voltage Measurement... 22:07:58 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000001090 V 22:07:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158435858 Vs 22:07:58 Integrated Voltage Measurement... 22:08:20 Voltage Offset Correction: v_off_ini = -0.000001243 V, v_off_fin = -0.000003277 V 22:08:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376719 Vs 22:08:34 Temperature Measurement, Probe Number = 0, T = 20.145000 C 22:08:35 Temperature Measurement, Probe Number = 1, T = 20.115000 C 22:08:35 Temperature Measurement, Probe Number = 2, T = 20.158000 C 22:08:36 Temperature Measurement, Probe Number = 3, T = 20.115000 C 22:08:36 Temperature Measurement, Probe Number = 4, T = 20.137000 C 22:08:37 Temperature Measurement, Probe Number = 5, T = 20.074000 C 22:08:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:08:37 Integrated Voltage Measurement... 22:08:59 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000001258 V 22:08:59 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158425783 Vs 22:08:59 Integrated Voltage Measurement... 22:09:21 Voltage Offset Correction: v_off_ini = -0.000003306 V, v_off_fin = -0.000001990 V 22:09:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365948 Vs 22:09:35 Temperature Measurement, Probe Number = 0, T = 20.162000 C 22:09:36 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:09:36 Temperature Measurement, Probe Number = 2, T = 20.155000 C 22:09:37 Temperature Measurement, Probe Number = 3, T = 20.115000 C 22:09:37 Temperature Measurement, Probe Number = 4, T = 20.135000 C 22:09:38 Temperature Measurement, Probe Number = 5, T = 20.073000 C 22:09:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:09:38 Integrated Voltage Measurement... 22:10:00 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001360 V 22:10:00 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158434995 Vs 22:10:00 Integrated Voltage Measurement... 22:10:23 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000001185 V 22:10:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403325 Vs 22:10:36 Temperature Measurement, Probe Number = 0, T = 20.158000 C 22:10:37 Temperature Measurement, Probe Number = 1, T = 20.113000 C 22:10:37 Temperature Measurement, Probe Number = 2, T = 20.160000 C 22:10:38 Temperature Measurement, Probe Number = 3, T = 20.115000 C 22:10:39 Temperature Measurement, Probe Number = 4, T = 20.136000 C 22:10:39 Temperature Measurement, Probe Number = 5, T = 20.072000 C 22:10:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:10:39 Integrated Voltage Measurement... 22:11:02 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000000863 V 22:11:02 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158419352 Vs 22:11:02 Integrated Voltage Measurement... 22:11:24 Voltage Offset Correction: v_off_ini = -0.000002253 V, v_off_fin = -0.000004981 V 22:11:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158344682 Vs 22:11:38 Temperature Measurement, Probe Number = 0, T = 20.153000 C 22:11:38 Temperature Measurement, Probe Number = 1, T = 20.114000 C 22:11:39 Temperature Measurement, Probe Number = 2, T = 20.160000 C 22:11:40 Temperature Measurement, Probe Number = 3, T = 20.114000 C 22:11:40 Temperature Measurement, Probe Number = 4, T = 20.137000 C 22:11:41 Temperature Measurement, Probe Number = 5, T = 20.075000 C 22:11:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.11 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:11:41 Integrated Voltage Measurement... 22:12:03 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001156 V 22:12:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411210 Vs 22:12:03 Integrated Voltage Measurement... 22:12:25 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = -0.000002546 V 22:12:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396313 Vs 22:12:39 Temperature Measurement, Probe Number = 0, T = 20.131000 C 22:12:39 Temperature Measurement, Probe Number = 1, T = 20.114000 C 22:12:40 Temperature Measurement, Probe Number = 2, T = 20.160000 C 22:12:41 Temperature Measurement, Probe Number = 3, T = 20.116000 C 22:12:41 Temperature Measurement, Probe Number = 4, T = 20.136000 C 22:12:42 Temperature Measurement, Probe Number = 5, T = 20.074000 C 22:12:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.16 P4 = Encode_Arm, Value = 20.12 P5 = Bottom_Jaw, Value = 20.14 P6 = Top_Jaw, Value = 20.07 22:12:42 Integrated Voltage Measurement... 22:13:04 Voltage Offset Correction: v_off_ini = -0.000001390 V, v_off_fin = 0.000001338 V 22:13:04 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158391655 Vs 22:13:04 Integrated Voltage Measurement... 22:13:26 Voltage Offset Correction: v_off_ini = 0.000000256 V, v_off_fin = -0.000001002 V 22:13:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407302 Vs 23:09:40 Temperature Measurement, Probe Number = 0, T = 20.083000 C 23:09:40 Temperature Measurement, Probe Number = 1, T = 20.096000 C 23:09:41 Temperature Measurement, Probe Number = 2, T = 20.142000 C 23:09:42 Temperature Measurement, Probe Number = 3, T = 20.103000 C 23:09:42 Temperature Measurement, Probe Number = 4, T = 20.126000 C 23:09:43 Temperature Measurement, Probe Number = 5, T = 20.063000 C 23:09:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.06 23:09:43 Integrated Voltage Measurement... 23:10:05 Voltage Offset Correction: v_off_ini = -0.000003234 V, v_off_fin = -0.000001449 V 23:10:06 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158489466 Vs 23:10:06 Integrated Voltage Measurement... 23:10:28 Voltage Offset Correction: v_off_ini = -0.000000307 V, v_off_fin = -0.000002634 V 23:10:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430510 Vs 23:10:42 Temperature Measurement, Probe Number = 0, T = 20.072000 C 23:10:42 Temperature Measurement, Probe Number = 1, T = 20.102000 C 23:10:43 Temperature Measurement, Probe Number = 2, T = 20.146000 C 23:10:44 Temperature Measurement, Probe Number = 3, T = 20.101000 C 23:10:44 Temperature Measurement, Probe Number = 4, T = 20.128000 C 23:10:45 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:10:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:10:45 Integrated Voltage Measurement... 23:11:07 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000001434 V 23:11:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158439452 Vs 23:11:07 Integrated Voltage Measurement... 23:11:29 Voltage Offset Correction: v_off_ini = -0.000000066 V, v_off_fin = -0.000000746 V 23:11:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439100 Vs 23:11:43 Temperature Measurement, Probe Number = 0, T = 20.072000 C 23:11:43 Temperature Measurement, Probe Number = 1, T = 20.097000 C 23:11:44 Temperature Measurement, Probe Number = 2, T = 20.144000 C 23:11:45 Temperature Measurement, Probe Number = 3, T = 20.097000 C 23:11:45 Temperature Measurement, Probe Number = 4, T = 20.128000 C 23:11:46 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:11:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:11:46 Integrated Voltage Measurement... 23:12:08 Voltage Offset Correction: v_off_ini = -0.000001888 V, v_off_fin = -0.000004179 V 23:12:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158479511 Vs 23:12:09 Integrated Voltage Measurement... 23:12:31 Voltage Offset Correction: v_off_ini = -0.000000776 V, v_off_fin = -0.000003425 V 23:12:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419705 Vs 23:12:45 Temperature Measurement, Probe Number = 0, T = 20.059000 C 23:12:45 Temperature Measurement, Probe Number = 1, T = 20.099000 C 23:12:46 Temperature Measurement, Probe Number = 2, T = 20.146000 C 23:12:47 Temperature Measurement, Probe Number = 3, T = 20.101000 C 23:12:47 Temperature Measurement, Probe Number = 4, T = 20.127000 C 23:12:48 Temperature Measurement, Probe Number = 5, T = 20.064000 C 23:12:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.06 23:12:48 Integrated Voltage Measurement... 23:13:10 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = -0.000000373 V 23:13:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453124 Vs 23:13:10 Integrated Voltage Measurement... 23:13:32 Voltage Offset Correction: v_off_ini = 0.000000073 V, v_off_fin = -0.000000974 V 23:13:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427347 Vs 23:13:46 Temperature Measurement, Probe Number = 0, T = 20.103000 C 23:13:46 Temperature Measurement, Probe Number = 1, T = 20.103000 C 23:13:47 Temperature Measurement, Probe Number = 2, T = 20.148000 C 23:13:48 Temperature Measurement, Probe Number = 3, T = 20.104000 C 23:13:48 Temperature Measurement, Probe Number = 4, T = 20.129000 C 23:13:49 Temperature Measurement, Probe Number = 5, T = 20.066000 C 23:13:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:13:49 Integrated Voltage Measurement... 23:14:11 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = 0.000001317 V 23:14:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158436564 Vs 23:14:11 Integrated Voltage Measurement... 23:14:33 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000000688 V 23:14:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158445477 Vs 23:14:47 Temperature Measurement, Probe Number = 0, T = 20.133000 C 23:14:47 Temperature Measurement, Probe Number = 1, T = 20.101000 C 23:14:48 Temperature Measurement, Probe Number = 2, T = 20.148000 C 23:14:49 Temperature Measurement, Probe Number = 3, T = 20.103000 C 23:14:49 Temperature Measurement, Probe Number = 4, T = 20.129000 C 23:14:50 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:14:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:14:50 Integrated Voltage Measurement... 23:15:12 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000000029 V 23:15:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158444886 Vs 23:15:12 Integrated Voltage Measurement... 23:15:34 Voltage Offset Correction: v_off_ini = -0.000002731 V, v_off_fin = -0.000001786 V 23:15:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421586 Vs 23:15:48 Temperature Measurement, Probe Number = 0, T = 20.126000 C 23:15:49 Temperature Measurement, Probe Number = 1, T = 20.107000 C 23:15:49 Temperature Measurement, Probe Number = 2, T = 20.151000 C 23:15:50 Temperature Measurement, Probe Number = 3, T = 20.101000 C 23:15:50 Temperature Measurement, Probe Number = 4, T = 20.130000 C 23:15:51 Temperature Measurement, Probe Number = 5, T = 20.066000 C 23:15:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:15:51 Integrated Voltage Measurement... 23:16:13 Voltage Offset Correction: v_off_ini = -0.000001113 V, v_off_fin = -0.000001464 V 23:16:14 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158443814 Vs 23:16:14 Integrated Voltage Measurement... 23:16:36 Voltage Offset Correction: v_off_ini = -0.000000264 V, v_off_fin = -0.000001493 V 23:16:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426309 Vs 23:16:50 Temperature Measurement, Probe Number = 0, T = 20.100000 C 23:16:50 Temperature Measurement, Probe Number = 1, T = 20.102000 C 23:16:51 Temperature Measurement, Probe Number = 2, T = 20.148000 C 23:16:52 Temperature Measurement, Probe Number = 3, T = 20.101000 C 23:16:52 Temperature Measurement, Probe Number = 4, T = 20.129000 C 23:16:53 Temperature Measurement, Probe Number = 5, T = 20.064000 C 23:16:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.06 23:16:53 Integrated Voltage Measurement... 23:17:15 Voltage Offset Correction: v_off_ini = -0.000001881 V, v_off_fin = -0.000002137 V 23:17:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456431 Vs 23:17:15 Integrated Voltage Measurement... 23:17:37 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000001405 V 23:17:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404388 Vs 23:17:51 Temperature Measurement, Probe Number = 0, T = 20.094000 C 23:17:51 Temperature Measurement, Probe Number = 1, T = 20.101000 C 23:17:52 Temperature Measurement, Probe Number = 2, T = 20.147000 C 23:17:53 Temperature Measurement, Probe Number = 3, T = 20.100000 C 23:17:53 Temperature Measurement, Probe Number = 4, T = 20.129000 C 23:17:54 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:17:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:17:54 Integrated Voltage Measurement... 23:18:16 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000000849 V 23:18:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158448885 Vs 23:18:16 Integrated Voltage Measurement... 23:18:39 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = -0.000003111 V 23:18:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433016 Vs 23:18:52 Temperature Measurement, Probe Number = 0, T = 20.095000 C 23:18:53 Temperature Measurement, Probe Number = 1, T = 20.100000 C 23:18:53 Temperature Measurement, Probe Number = 2, T = 20.148000 C 23:18:54 Temperature Measurement, Probe Number = 3, T = 20.100000 C 23:18:55 Temperature Measurement, Probe Number = 4, T = 20.129000 C 23:18:55 Temperature Measurement, Probe Number = 5, T = 20.066000 C 23:18:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 23:18:55 Integrated Voltage Measurement... 23:19:17 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000002137 V 23:19:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456388 Vs 23:19:18 Integrated Voltage Measurement... 23:19:40 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = -0.000002203 V 23:19:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436357 Vs 00:15:54 Temperature Measurement, Probe Number = 0, T = 20.070000 C 00:15:54 Temperature Measurement, Probe Number = 1, T = 20.090000 C 00:15:55 Temperature Measurement, Probe Number = 2, T = 20.135000 C 00:15:56 Temperature Measurement, Probe Number = 3, T = 20.087000 C 00:15:56 Temperature Measurement, Probe Number = 4, T = 20.118000 C 00:15:57 Temperature Measurement, Probe Number = 5, T = 20.056000 C 00:15:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.06 00:15:57 Integrated Voltage Measurement... 00:16:19 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000000966 V 00:16:19 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158476489 Vs 00:16:19 Integrated Voltage Measurement... 00:16:41 Voltage Offset Correction: v_off_ini = -0.000001230 V, v_off_fin = -0.000002408 V 00:16:41 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158435789 Vs 00:16:55 Temperature Measurement, Probe Number = 0, T = 20.084000 C 00:16:55 Temperature Measurement, Probe Number = 1, T = 20.090000 C 00:16:56 Temperature Measurement, Probe Number = 2, T = 20.136000 C 00:16:57 Temperature Measurement, Probe Number = 3, T = 20.087000 C 00:16:57 Temperature Measurement, Probe Number = 4, T = 20.118000 C 00:16:58 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:16:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:16:58 Integrated Voltage Measurement... 00:17:20 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000000483 V 00:17:20 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158471497 Vs 00:17:20 Integrated Voltage Measurement... 00:17:42 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000002964 V 00:17:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438359 Vs 00:17:56 Temperature Measurement, Probe Number = 0, T = 20.070000 C 00:17:57 Temperature Measurement, Probe Number = 1, T = 20.088000 C 00:17:57 Temperature Measurement, Probe Number = 2, T = 20.139000 C 00:17:58 Temperature Measurement, Probe Number = 3, T = 20.085000 C 00:17:58 Temperature Measurement, Probe Number = 4, T = 20.116000 C 00:17:59 Temperature Measurement, Probe Number = 5, T = 20.054000 C 00:17:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:17:59 Integrated Voltage Measurement... 00:18:21 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000001581 V 00:18:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158473254 Vs 00:18:21 Integrated Voltage Measurement... 00:18:44 Voltage Offset Correction: v_off_ini = -0.000002737 V, v_off_fin = -0.000002796 V 00:18:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426201 Vs 00:18:57 Temperature Measurement, Probe Number = 0, T = 20.081000 C 00:18:58 Temperature Measurement, Probe Number = 1, T = 20.092000 C 00:18:58 Temperature Measurement, Probe Number = 2, T = 20.139000 C 00:18:59 Temperature Measurement, Probe Number = 3, T = 20.083000 C 00:19:00 Temperature Measurement, Probe Number = 4, T = 20.119000 C 00:19:00 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:19:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:19:00 Integrated Voltage Measurement... 00:19:22 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000000476 V 00:19:22 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158454565 Vs 00:19:22 Integrated Voltage Measurement... 00:19:45 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = -0.000002466 V 00:19:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158456723 Vs 00:19:58 Temperature Measurement, Probe Number = 0, T = 20.083000 C 00:19:59 Temperature Measurement, Probe Number = 1, T = 20.089000 C 00:20:00 Temperature Measurement, Probe Number = 2, T = 20.136000 C 00:20:00 Temperature Measurement, Probe Number = 3, T = 20.083000 C 00:20:01 Temperature Measurement, Probe Number = 4, T = 20.117000 C 00:20:01 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:20:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:20:01 Integrated Voltage Measurement... 00:20:24 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000988 V 00:20:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158460785 Vs 00:20:24 Integrated Voltage Measurement... 00:20:46 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000002218 V 00:20:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439641 Vs 00:21:00 Temperature Measurement, Probe Number = 0, T = 20.050000 C 00:21:01 Temperature Measurement, Probe Number = 1, T = 20.089000 C 00:21:01 Temperature Measurement, Probe Number = 2, T = 20.135000 C 00:21:02 Temperature Measurement, Probe Number = 3, T = 20.083000 C 00:21:02 Temperature Measurement, Probe Number = 4, T = 20.117000 C 00:21:03 Temperature Measurement, Probe Number = 5, T = 20.054000 C 00:21:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:21:03 Integrated Voltage Measurement... 00:21:25 Voltage Offset Correction: v_off_ini = -0.000002202 V, v_off_fin = -0.000001932 V 00:21:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158475556 Vs 00:21:26 Integrated Voltage Measurement... 00:21:48 Voltage Offset Correction: v_off_ini = -0.000000373 V, v_off_fin = -0.000001098 V 00:21:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440640 Vs 00:22:02 Temperature Measurement, Probe Number = 0, T = 20.088000 C 00:22:02 Temperature Measurement, Probe Number = 1, T = 20.095000 C 00:22:03 Temperature Measurement, Probe Number = 2, T = 20.142000 C 00:22:04 Temperature Measurement, Probe Number = 3, T = 20.086000 C 00:22:04 Temperature Measurement, Probe Number = 4, T = 20.118000 C 00:22:05 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:22:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:22:05 Integrated Voltage Measurement... 00:22:27 Voltage Offset Correction: v_off_ini = -0.000002443 V, v_off_fin = -0.000001470 V 00:22:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158474558 Vs 00:22:27 Integrated Voltage Measurement... 00:22:50 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000001581 V 00:22:50 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158439138 Vs 00:23:03 Temperature Measurement, Probe Number = 0, T = 20.104000 C 00:23:04 Temperature Measurement, Probe Number = 1, T = 20.089000 C 00:23:04 Temperature Measurement, Probe Number = 2, T = 20.136000 C 00:23:05 Temperature Measurement, Probe Number = 3, T = 20.084000 C 00:23:06 Temperature Measurement, Probe Number = 4, T = 20.117000 C 00:23:06 Temperature Measurement, Probe Number = 5, T = 20.051000 C 00:23:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:23:06 Integrated Voltage Measurement... 00:23:28 Voltage Offset Correction: v_off_ini = -0.000001961 V, v_off_fin = -0.000002253 V 00:23:28 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158475352 Vs 00:23:28 Integrated Voltage Measurement... 00:23:50 Voltage Offset Correction: v_off_ini = 0.000000227 V, v_off_fin = -0.000002100 V 00:23:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442713 Vs 00:24:04 Temperature Measurement, Probe Number = 0, T = 20.074000 C 00:24:05 Temperature Measurement, Probe Number = 1, T = 20.089000 C 00:24:05 Temperature Measurement, Probe Number = 2, T = 20.135000 C 00:24:06 Temperature Measurement, Probe Number = 3, T = 20.082000 C 00:24:06 Temperature Measurement, Probe Number = 4, T = 20.116000 C 00:24:07 Temperature Measurement, Probe Number = 5, T = 20.053000 C 00:24:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.05 00:24:07 Integrated Voltage Measurement... 00:24:29 Voltage Offset Correction: v_off_ini = -0.000001419 V, v_off_fin = 0.000000615 V 00:24:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455658 Vs 00:24:29 Integrated Voltage Measurement... 00:24:51 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000001756 V 00:24:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432400 Vs 00:25:05 Temperature Measurement, Probe Number = 0, T = 20.067000 C 00:25:06 Temperature Measurement, Probe Number = 1, T = 20.087000 C 00:25:06 Temperature Measurement, Probe Number = 2, T = 20.133000 C 00:25:07 Temperature Measurement, Probe Number = 3, T = 20.083000 C 00:25:08 Temperature Measurement, Probe Number = 4, T = 20.115000 C 00:25:08 Temperature Measurement, Probe Number = 5, T = 20.052000 C 00:25:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.05 00:25:08 Integrated Voltage Measurement... 00:25:31 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = 0.000000322 V 00:25:31 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158462901 Vs 00:25:31 Integrated Voltage Measurement... 00:25:53 Voltage Offset Correction: v_off_ini = 0.000000761 V, v_off_fin = -0.000002196 V 00:25:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439795 Vs 01:22:07 Temperature Measurement, Probe Number = 0, T = 20.058000 C 01:22:07 Temperature Measurement, Probe Number = 1, T = 20.080000 C 01:22:08 Temperature Measurement, Probe Number = 2, T = 20.122000 C 01:22:09 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:22:09 Temperature Measurement, Probe Number = 4, T = 20.104000 C 01:22:10 Temperature Measurement, Probe Number = 5, T = 20.043000 C 01:22:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 01:22:10 Integrated Voltage Measurement... 01:22:32 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000001690 V 01:22:32 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158472981 Vs 01:22:32 Integrated Voltage Measurement... 01:22:57 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000002049 V 01:22:57 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158413015 Vs 01:23:11 Temperature Measurement, Probe Number = 0, T = 20.073000 C 01:23:12 Temperature Measurement, Probe Number = 1, T = 20.075000 C 01:23:12 Temperature Measurement, Probe Number = 2, T = 20.122000 C 01:23:13 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:23:13 Temperature Measurement, Probe Number = 4, T = 20.104000 C 01:23:14 Temperature Measurement, Probe Number = 5, T = 20.043000 C 01:23:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 01:23:14 Integrated Voltage Measurement... 01:23:36 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000000622 V 01:23:36 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158433318 Vs 01:23:36 Integrated Voltage Measurement... 01:23:58 Voltage Offset Correction: v_off_ini = -0.000000981 V, v_off_fin = -0.000002811 V 01:23:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418476 Vs 01:24:12 Temperature Measurement, Probe Number = 0, T = 20.064000 C 01:24:12 Temperature Measurement, Probe Number = 1, T = 20.076000 C 01:24:13 Temperature Measurement, Probe Number = 2, T = 20.124000 C 01:24:14 Temperature Measurement, Probe Number = 3, T = 20.071000 C 01:24:14 Temperature Measurement, Probe Number = 4, T = 20.106000 C 01:24:15 Temperature Measurement, Probe Number = 5, T = 20.043000 C 01:24:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.04 01:24:15 Integrated Voltage Measurement... 01:24:37 Voltage Offset Correction: v_off_ini = -0.000002034 V, v_off_fin = -0.000001405 V 01:24:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158461339 Vs 01:24:37 Integrated Voltage Measurement... 01:25:00 Voltage Offset Correction: v_off_ini = 0.000001449 V, v_off_fin = -0.000003374 V 01:25:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448119 Vs 01:25:13 Temperature Measurement, Probe Number = 0, T = 20.119000 C 01:25:14 Temperature Measurement, Probe Number = 1, T = 20.078000 C 01:25:14 Temperature Measurement, Probe Number = 2, T = 20.126000 C 01:25:15 Temperature Measurement, Probe Number = 3, T = 20.072000 C 01:25:16 Temperature Measurement, Probe Number = 4, T = 20.106000 C 01:25:16 Temperature Measurement, Probe Number = 5, T = 20.042000 C 01:25:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.04 01:25:16 Integrated Voltage Measurement... 01:25:38 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000000424 V 01:25:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441373 Vs 01:25:38 Integrated Voltage Measurement... 01:26:01 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000003776 V 01:26:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437673 Vs 01:26:14 Temperature Measurement, Probe Number = 0, T = 20.139000 C 01:26:15 Temperature Measurement, Probe Number = 1, T = 20.077000 C 01:26:16 Temperature Measurement, Probe Number = 2, T = 20.125000 C 01:26:16 Temperature Measurement, Probe Number = 3, T = 20.070000 C 01:26:17 Temperature Measurement, Probe Number = 4, T = 20.104000 C 01:26:17 Temperature Measurement, Probe Number = 5, T = 20.043000 C 01:26:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 01:26:17 Integrated Voltage Measurement... 01:26:40 Voltage Offset Correction: v_off_ini = -0.000002028 V, v_off_fin = -0.000000329 V 01:26:40 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158437577 Vs 01:26:40 Integrated Voltage Measurement... 01:27:02 Voltage Offset Correction: v_off_ini = 0.000000183 V, v_off_fin = -0.000002042 V 01:27:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424157 Vs 01:27:15 Temperature Measurement, Probe Number = 0, T = 20.141000 C 01:27:16 Temperature Measurement, Probe Number = 1, T = 20.080000 C 01:27:17 Temperature Measurement, Probe Number = 2, T = 20.127000 C 01:27:17 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:27:18 Temperature Measurement, Probe Number = 4, T = 20.105000 C 01:27:18 Temperature Measurement, Probe Number = 5, T = 20.044000 C 01:27:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.04 01:27:18 Integrated Voltage Measurement... 01:27:41 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000004274 V 01:27:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158473976 Vs 01:27:41 Integrated Voltage Measurement... 01:28:12 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = -0.000002349 V 01:28:12 Integrated Voltage Measurement Delta Gap = -0.0040000 m VT = -0.158411162 Vs 01:28:26 Temperature Measurement, Probe Number = 0, T = 20.125000 C 01:28:26 Temperature Measurement, Probe Number = 1, T = 20.079000 C 01:28:27 Temperature Measurement, Probe Number = 2, T = 20.126000 C 01:28:27 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:28:28 Temperature Measurement, Probe Number = 4, T = 20.105000 C 01:28:29 Temperature Measurement, Probe Number = 5, T = 20.042000 C 01:28:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.04 01:28:29 Integrated Voltage Measurement... 01:28:51 Voltage Offset Correction: v_off_ini = -0.000001179 V, v_off_fin = -0.000000710 V 01:28:51 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158436360 Vs 01:28:51 Integrated Voltage Measurement... 01:29:13 Voltage Offset Correction: v_off_ini = -0.000000666 V, v_off_fin = -0.000002225 V 01:29:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420576 Vs 01:29:27 Temperature Measurement, Probe Number = 0, T = 20.111000 C 01:29:28 Temperature Measurement, Probe Number = 1, T = 20.077000 C 01:29:28 Temperature Measurement, Probe Number = 2, T = 20.124000 C 01:29:29 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:29:29 Temperature Measurement, Probe Number = 4, T = 20.104000 C 01:29:30 Temperature Measurement, Probe Number = 5, T = 20.043000 C 01:29:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 01:29:30 Integrated Voltage Measurement... 01:29:52 Voltage Offset Correction: v_off_ini = -0.000001757 V, v_off_fin = -0.000002759 V 01:29:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158464377 Vs 01:29:52 Integrated Voltage Measurement... 01:30:14 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = -0.000000776 V 01:30:15 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158423977 Vs 01:30:28 Temperature Measurement, Probe Number = 0, T = 20.117000 C 01:30:29 Temperature Measurement, Probe Number = 1, T = 20.077000 C 01:30:29 Temperature Measurement, Probe Number = 2, T = 20.126000 C 01:30:30 Temperature Measurement, Probe Number = 3, T = 20.066000 C 01:30:31 Temperature Measurement, Probe Number = 4, T = 20.105000 C 01:30:31 Temperature Measurement, Probe Number = 5, T = 20.042000 C 01:30:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.04 01:30:31 Integrated Voltage Measurement... 01:30:53 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000000527 V 01:30:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158419630 Vs 01:30:53 Integrated Voltage Measurement... 01:31:16 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002430 V 01:31:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433572 Vs 01:31:29 Temperature Measurement, Probe Number = 0, T = 20.113000 C 01:31:30 Temperature Measurement, Probe Number = 1, T = 20.079000 C 01:31:30 Temperature Measurement, Probe Number = 2, T = 20.126000 C 01:31:31 Temperature Measurement, Probe Number = 3, T = 20.066000 C 01:31:32 Temperature Measurement, Probe Number = 4, T = 20.104000 C 01:31:32 Temperature Measurement, Probe Number = 5, T = 20.042000 C 01:31:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 01:31:32 Integrated Voltage Measurement... 01:31:54 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000000351 V 01:31:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158441012 Vs 01:31:54 Integrated Voltage Measurement... 01:32:17 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000002020 V 01:32:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423465 Vs 02:28:30 Temperature Measurement, Probe Number = 0, T = 20.052000 C 02:28:31 Temperature Measurement, Probe Number = 1, T = 20.077000 C 02:28:31 Temperature Measurement, Probe Number = 2, T = 20.115000 C 02:28:32 Temperature Measurement, Probe Number = 3, T = 20.043000 C 02:28:33 Temperature Measurement, Probe Number = 4, T = 20.094000 C 02:28:33 Temperature Measurement, Probe Number = 5, T = 20.040000 C 02:28:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:28:33 Integrated Voltage Measurement... 02:29:05 Voltage Offset Correction: v_off_ini = -0.000001917 V, v_off_fin = -0.000001317 V 02:29:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158481567 Vs 02:29:05 Integrated Voltage Measurement... 02:29:27 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000002495 V 02:29:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404182 Vs 02:29:41 Temperature Measurement, Probe Number = 0, T = 20.053000 C 02:29:41 Temperature Measurement, Probe Number = 1, T = 20.082000 C 02:29:42 Temperature Measurement, Probe Number = 2, T = 20.118000 C 02:29:43 Temperature Measurement, Probe Number = 3, T = 20.039000 C 02:29:43 Temperature Measurement, Probe Number = 4, T = 20.096000 C 02:29:44 Temperature Measurement, Probe Number = 5, T = 20.042000 C 02:29:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.04 02:29:44 Integrated Voltage Measurement... 02:30:06 Voltage Offset Correction: v_off_ini = -0.000002254 V, v_off_fin = -0.000000776 V 02:30:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158419481 Vs 02:30:06 Integrated Voltage Measurement... 02:30:29 Voltage Offset Correction: v_off_ini = 0.000002400 V, v_off_fin = -0.000002085 V 02:30:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424429 Vs 02:30:42 Temperature Measurement, Probe Number = 0, T = 20.021000 C 02:30:43 Temperature Measurement, Probe Number = 1, T = 20.077000 C 02:30:43 Temperature Measurement, Probe Number = 2, T = 20.121000 C 02:30:44 Temperature Measurement, Probe Number = 3, T = 20.038000 C 02:30:45 Temperature Measurement, Probe Number = 4, T = 20.095000 C 02:30:45 Temperature Measurement, Probe Number = 5, T = 20.042000 C 02:30:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:30:45 Integrated Voltage Measurement... 02:31:07 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000001032 V 02:31:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158444655 Vs 02:31:08 Integrated Voltage Measurement... 02:31:30 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000001259 V 02:31:30 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158395905 Vs 02:31:44 Temperature Measurement, Probe Number = 0, T = 20.039000 C 02:31:44 Temperature Measurement, Probe Number = 1, T = 20.077000 C 02:31:45 Temperature Measurement, Probe Number = 2, T = 20.116000 C 02:31:46 Temperature Measurement, Probe Number = 3, T = 20.037000 C 02:31:46 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:31:47 Temperature Measurement, Probe Number = 5, T = 20.040000 C 02:31:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:31:47 Integrated Voltage Measurement... 02:32:09 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000000783 V 02:32:09 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158431377 Vs 02:32:09 Integrated Voltage Measurement... 02:32:31 Voltage Offset Correction: v_off_ini = 0.000000812 V, v_off_fin = -0.000002869 V 02:32:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158408810 Vs 02:32:45 Temperature Measurement, Probe Number = 0, T = 20.015000 C 02:32:46 Temperature Measurement, Probe Number = 1, T = 20.076000 C 02:32:46 Temperature Measurement, Probe Number = 2, T = 20.113000 C 02:32:47 Temperature Measurement, Probe Number = 3, T = 20.036000 C 02:32:47 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:32:48 Temperature Measurement, Probe Number = 5, T = 20.039000 C 02:32:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:32:48 Integrated Voltage Measurement... 02:33:10 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = 0.000000168 V 02:33:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425970 Vs 02:33:10 Integrated Voltage Measurement... 02:33:32 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = -0.000003703 V 02:33:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413808 Vs 02:33:46 Temperature Measurement, Probe Number = 0, T = 20.010000 C 02:33:47 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:33:47 Temperature Measurement, Probe Number = 2, T = 20.113000 C 02:33:48 Temperature Measurement, Probe Number = 3, T = 20.035000 C 02:33:48 Temperature Measurement, Probe Number = 4, T = 20.091000 C 02:33:49 Temperature Measurement, Probe Number = 5, T = 20.038000 C 02:33:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:33:49 Integrated Voltage Measurement... 02:34:11 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000000117 V 02:34:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411208 Vs 02:34:11 Integrated Voltage Measurement... 02:34:36 Voltage Offset Correction: v_off_ini = 0.000000812 V, v_off_fin = -0.000001661 V 02:34:37 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158428904 Vs 02:34:50 Temperature Measurement, Probe Number = 0, T = 19.999000 C 02:34:51 Temperature Measurement, Probe Number = 1, T = 20.071000 C 02:34:52 Temperature Measurement, Probe Number = 2, T = 20.112000 C 02:34:52 Temperature Measurement, Probe Number = 3, T = 20.038000 C 02:34:53 Temperature Measurement, Probe Number = 4, T = 20.091000 C 02:34:53 Temperature Measurement, Probe Number = 5, T = 20.038000 C 02:34:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:34:53 Integrated Voltage Measurement... 02:35:16 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000001837 V 02:35:16 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158420863 Vs 02:35:16 Integrated Voltage Measurement... 02:35:38 Voltage Offset Correction: v_off_ini = -0.000000827 V, v_off_fin = -0.000002086 V 02:35:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407990 Vs 02:35:52 Temperature Measurement, Probe Number = 0, T = 20.034000 C 02:35:52 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:35:53 Temperature Measurement, Probe Number = 2, T = 20.113000 C 02:35:54 Temperature Measurement, Probe Number = 3, T = 20.039000 C 02:35:54 Temperature Measurement, Probe Number = 4, T = 20.090000 C 02:35:55 Temperature Measurement, Probe Number = 5, T = 20.039000 C 02:35:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:35:55 Integrated Voltage Measurement... 02:36:17 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000000907 V 02:36:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158434701 Vs 02:36:17 Integrated Voltage Measurement... 02:36:39 Voltage Offset Correction: v_off_ini = -0.000003103 V, v_off_fin = -0.000002730 V 02:36:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376584 Vs 02:36:53 Temperature Measurement, Probe Number = 0, T = 20.043000 C 02:36:54 Temperature Measurement, Probe Number = 1, T = 20.074000 C 02:36:54 Temperature Measurement, Probe Number = 2, T = 20.114000 C 02:36:55 Temperature Measurement, Probe Number = 3, T = 20.039000 C 02:36:55 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:36:56 Temperature Measurement, Probe Number = 5, T = 20.038000 C 02:36:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:36:56 Integrated Voltage Measurement... 02:37:18 Voltage Offset Correction: v_off_ini = -0.000000864 V, v_off_fin = 0.000001442 V 02:37:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158396482 Vs 02:37:18 Integrated Voltage Measurement... 02:37:41 Voltage Offset Correction: v_off_ini = -0.000002905 V, v_off_fin = -0.000000995 V 02:37:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381046 Vs 02:37:54 Temperature Measurement, Probe Number = 0, T = 20.032000 C 02:37:55 Temperature Measurement, Probe Number = 1, T = 20.074000 C 02:37:55 Temperature Measurement, Probe Number = 2, T = 20.113000 C 02:37:56 Temperature Measurement, Probe Number = 3, T = 20.039000 C 02:37:57 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:37:57 Temperature Measurement, Probe Number = 5, T = 20.038000 C 02:37:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.04 02:37:57 Integrated Voltage Measurement... 02:38:19 Voltage Offset Correction: v_off_ini = -0.000002664 V, v_off_fin = -0.000001149 V 02:38:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441163 Vs 02:38:19 Integrated Voltage Measurement... 02:38:42 Voltage Offset Correction: v_off_ini = -0.000001880 V, v_off_fin = -0.000002268 V 02:38:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383316 Vs 03:34:56 Temperature Measurement, Probe Number = 0, T = 19.966000 C 03:34:56 Temperature Measurement, Probe Number = 1, T = 20.070000 C 03:34:57 Temperature Measurement, Probe Number = 2, T = 20.099000 C 03:34:58 Temperature Measurement, Probe Number = 3, T = 20.016000 C 03:34:58 Temperature Measurement, Probe Number = 4, T = 20.076000 C 03:34:59 Temperature Measurement, Probe Number = 5, T = 20.030000 C 03:34:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:34:59 Integrated Voltage Measurement... 03:35:21 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000001038 V 03:35:21 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158455069 Vs 03:35:21 Integrated Voltage Measurement... 03:35:43 Voltage Offset Correction: v_off_ini = -0.000002092 V, v_off_fin = -0.000000856 V 03:35:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386919 Vs 03:35:57 Temperature Measurement, Probe Number = 0, T = 19.940000 C 03:35:58 Temperature Measurement, Probe Number = 1, T = 20.069000 C 03:35:58 Temperature Measurement, Probe Number = 2, T = 20.098000 C 03:35:59 Temperature Measurement, Probe Number = 3, T = 20.016000 C 03:35:59 Temperature Measurement, Probe Number = 4, T = 20.076000 C 03:36:00 Temperature Measurement, Probe Number = 5, T = 20.030000 C 03:36:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:36:00 Integrated Voltage Measurement... 03:36:22 Voltage Offset Correction: v_off_ini = -0.000001858 V, v_off_fin = -0.000000527 V 03:36:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411538 Vs 03:36:22 Integrated Voltage Measurement... 03:36:46 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000002787 V 03:36:46 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158391026 Vs 03:36:59 Temperature Measurement, Probe Number = 0, T = 19.954000 C 03:37:00 Temperature Measurement, Probe Number = 1, T = 20.073000 C 03:37:00 Temperature Measurement, Probe Number = 2, T = 20.098000 C 03:37:01 Temperature Measurement, Probe Number = 3, T = 20.018000 C 03:37:02 Temperature Measurement, Probe Number = 4, T = 20.076000 C 03:37:02 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:37:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:37:02 Integrated Voltage Measurement... 03:37:24 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001521 V 03:37:24 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158400018 Vs 03:37:24 Integrated Voltage Measurement... 03:37:47 Voltage Offset Correction: v_off_ini = -0.000000636 V, v_off_fin = -0.000001960 V 03:37:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399152 Vs 03:38:00 Temperature Measurement, Probe Number = 0, T = 19.963000 C 03:38:01 Temperature Measurement, Probe Number = 1, T = 20.072000 C 03:38:02 Temperature Measurement, Probe Number = 2, T = 20.100000 C 03:38:02 Temperature Measurement, Probe Number = 3, T = 20.017000 C 03:38:03 Temperature Measurement, Probe Number = 4, T = 20.077000 C 03:38:03 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:38:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:38:03 Integrated Voltage Measurement... 03:38:26 Voltage Offset Correction: v_off_ini = -0.000000475 V, v_off_fin = -0.000001178 V 03:38:26 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158413451 Vs 03:38:26 Integrated Voltage Measurement... 03:38:48 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000001383 V 03:38:48 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158404205 Vs 03:39:02 Temperature Measurement, Probe Number = 0, T = 19.951000 C 03:39:03 Temperature Measurement, Probe Number = 1, T = 20.071000 C 03:39:03 Temperature Measurement, Probe Number = 2, T = 20.099000 C 03:39:04 Temperature Measurement, Probe Number = 3, T = 20.019000 C 03:39:04 Temperature Measurement, Probe Number = 4, T = 20.075000 C 03:39:05 Temperature Measurement, Probe Number = 5, T = 20.030000 C 03:39:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.03 03:39:05 Integrated Voltage Measurement... 03:39:27 Voltage Offset Correction: v_off_ini = -0.000000293 V, v_off_fin = -0.000001551 V 03:39:27 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420144 Vs 03:39:27 Integrated Voltage Measurement... 03:39:50 Voltage Offset Correction: v_off_ini = -0.000000571 V, v_off_fin = -0.000002034 V 03:39:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404224 Vs 03:40:03 Temperature Measurement, Probe Number = 0, T = 20.013000 C 03:40:04 Temperature Measurement, Probe Number = 1, T = 20.070000 C 03:40:04 Temperature Measurement, Probe Number = 2, T = 20.100000 C 03:40:05 Temperature Measurement, Probe Number = 3, T = 20.019000 C 03:40:06 Temperature Measurement, Probe Number = 4, T = 20.077000 C 03:40:06 Temperature Measurement, Probe Number = 5, T = 20.030000 C 03:40:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:40:06 Integrated Voltage Measurement... 03:40:29 Voltage Offset Correction: v_off_ini = -0.000002465 V, v_off_fin = 0.000000351 V 03:40:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158414071 Vs 03:40:29 Integrated Voltage Measurement... 03:40:51 Voltage Offset Correction: v_off_ini = -0.000001939 V, v_off_fin = -0.000003160 V 03:40:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385178 Vs 03:41:05 Temperature Measurement, Probe Number = 0, T = 20.026000 C 03:41:05 Temperature Measurement, Probe Number = 1, T = 20.071000 C 03:41:06 Temperature Measurement, Probe Number = 2, T = 20.102000 C 03:41:07 Temperature Measurement, Probe Number = 3, T = 20.016000 C 03:41:07 Temperature Measurement, Probe Number = 4, T = 20.078000 C 03:41:08 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:41:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:41:08 Integrated Voltage Measurement... 03:41:30 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000002371 V 03:41:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158427338 Vs 03:41:30 Integrated Voltage Measurement... 03:41:52 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000002729 V 03:41:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401809 Vs 03:42:06 Temperature Measurement, Probe Number = 0, T = 19.992000 C 03:42:06 Temperature Measurement, Probe Number = 1, T = 20.071000 C 03:42:07 Temperature Measurement, Probe Number = 2, T = 20.104000 C 03:42:08 Temperature Measurement, Probe Number = 3, T = 20.015000 C 03:42:08 Temperature Measurement, Probe Number = 4, T = 20.076000 C 03:42:09 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:42:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:42:09 Integrated Voltage Measurement... 03:42:31 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000002839 V 03:42:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158436398 Vs 03:42:31 Integrated Voltage Measurement... 03:42:53 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000003145 V 03:42:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404099 Vs 03:43:07 Temperature Measurement, Probe Number = 0, T = 20.007000 C 03:43:07 Temperature Measurement, Probe Number = 1, T = 20.070000 C 03:43:08 Temperature Measurement, Probe Number = 2, T = 20.104000 C 03:43:09 Temperature Measurement, Probe Number = 3, T = 20.017000 C 03:43:09 Temperature Measurement, Probe Number = 4, T = 20.077000 C 03:43:10 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:43:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:43:10 Integrated Voltage Measurement... 03:43:32 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = 0.000004156 V 03:43:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393043 Vs 03:43:32 Integrated Voltage Measurement... 03:43:55 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = -0.000002773 V 03:43:55 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158389734 Vs 03:44:08 Temperature Measurement, Probe Number = 0, T = 19.971000 C 03:44:09 Temperature Measurement, Probe Number = 1, T = 20.073000 C 03:44:09 Temperature Measurement, Probe Number = 2, T = 20.103000 C 03:44:10 Temperature Measurement, Probe Number = 3, T = 20.013000 C 03:44:11 Temperature Measurement, Probe Number = 4, T = 20.076000 C 03:44:11 Temperature Measurement, Probe Number = 5, T = 20.031000 C 03:44:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.03 03:44:11 Integrated Voltage Measurement... 03:44:34 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = 0.000000146 V 03:44:35 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158423109 Vs 03:44:35 Integrated Voltage Measurement... 03:44:57 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000001924 V 03:44:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391072 Vs 04:41:11 Temperature Measurement, Probe Number = 0, T = 20.055000 C 04:41:11 Temperature Measurement, Probe Number = 1, T = 20.065000 C 04:41:12 Temperature Measurement, Probe Number = 2, T = 20.089000 C 04:41:13 Temperature Measurement, Probe Number = 3, T = 20.013000 C 04:41:13 Temperature Measurement, Probe Number = 4, T = 20.065000 C 04:41:14 Temperature Measurement, Probe Number = 5, T = 20.023000 C 04:41:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.02 04:41:14 Integrated Voltage Measurement... 04:41:36 Voltage Offset Correction: v_off_ini = -0.000000564 V, v_off_fin = -0.000000417 V 04:41:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158462955 Vs 04:41:37 Integrated Voltage Measurement... 04:41:59 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000002913 V 04:41:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394566 Vs 04:42:13 Temperature Measurement, Probe Number = 0, T = 20.026000 C 04:42:13 Temperature Measurement, Probe Number = 1, T = 20.067000 C 04:42:14 Temperature Measurement, Probe Number = 2, T = 20.089000 C 04:42:15 Temperature Measurement, Probe Number = 3, T = 20.011000 C 04:42:15 Temperature Measurement, Probe Number = 4, T = 20.064000 C 04:42:16 Temperature Measurement, Probe Number = 5, T = 20.025000 C 04:42:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:42:16 Integrated Voltage Measurement... 04:42:38 Voltage Offset Correction: v_off_ini = -0.000001325 V, v_off_fin = -0.000001003 V 04:42:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417690 Vs 04:42:38 Integrated Voltage Measurement... 04:43:00 Voltage Offset Correction: v_off_ini = -0.000000908 V, v_off_fin = -0.000002430 V 04:43:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388705 Vs 04:43:14 Temperature Measurement, Probe Number = 0, T = 19.978000 C 04:43:14 Temperature Measurement, Probe Number = 1, T = 20.066000 C 04:43:15 Temperature Measurement, Probe Number = 2, T = 20.088000 C 04:43:16 Temperature Measurement, Probe Number = 3, T = 20.010000 C 04:43:16 Temperature Measurement, Probe Number = 4, T = 20.062000 C 04:43:17 Temperature Measurement, Probe Number = 5, T = 20.025000 C 04:43:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:43:17 Integrated Voltage Measurement... 04:43:40 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000001068 V 04:43:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420694 Vs 04:43:40 Integrated Voltage Measurement... 04:44:02 Voltage Offset Correction: v_off_ini = -0.000001720 V, v_off_fin = -0.000001332 V 04:44:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158368408 Vs 04:44:16 Temperature Measurement, Probe Number = 0, T = 19.976000 C 04:44:17 Temperature Measurement, Probe Number = 1, T = 20.061000 C 04:44:17 Temperature Measurement, Probe Number = 2, T = 20.086000 C 04:44:18 Temperature Measurement, Probe Number = 3, T = 20.010000 C 04:44:18 Temperature Measurement, Probe Number = 4, T = 20.060000 C 04:44:19 Temperature Measurement, Probe Number = 5, T = 20.023000 C 04:44:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:44:19 Integrated Voltage Measurement... 04:44:41 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000000593 V 04:44:41 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158432247 Vs 04:44:41 Integrated Voltage Measurement... 04:45:04 Voltage Offset Correction: v_off_ini = -0.000002906 V, v_off_fin = -0.000003052 V 04:45:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371713 Vs 04:45:17 Temperature Measurement, Probe Number = 0, T = 19.972000 C 04:45:18 Temperature Measurement, Probe Number = 1, T = 20.064000 C 04:45:18 Temperature Measurement, Probe Number = 2, T = 20.085000 C 04:45:19 Temperature Measurement, Probe Number = 3, T = 20.009000 C 04:45:20 Temperature Measurement, Probe Number = 4, T = 20.061000 C 04:45:20 Temperature Measurement, Probe Number = 5, T = 20.025000 C 04:45:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:45:20 Integrated Voltage Measurement... 04:45:43 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000000446 V 04:45:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403921 Vs 04:45:43 Integrated Voltage Measurement... 04:46:05 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000002488 V 04:46:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388787 Vs 04:46:19 Temperature Measurement, Probe Number = 0, T = 19.956000 C 04:46:19 Temperature Measurement, Probe Number = 1, T = 20.058000 C 04:46:20 Temperature Measurement, Probe Number = 2, T = 20.080000 C 04:46:21 Temperature Measurement, Probe Number = 3, T = 20.007000 C 04:46:21 Temperature Measurement, Probe Number = 4, T = 20.060000 C 04:46:22 Temperature Measurement, Probe Number = 5, T = 20.023000 C 04:46:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:46:22 Integrated Voltage Measurement... 04:46:49 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = 0.000001339 V 04:46:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158383690 Vs 04:46:49 Integrated Voltage Measurement... 04:47:11 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000003102 V 04:47:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382582 Vs 04:47:25 Temperature Measurement, Probe Number = 0, T = 19.940000 C 04:47:25 Temperature Measurement, Probe Number = 1, T = 20.063000 C 04:47:26 Temperature Measurement, Probe Number = 2, T = 20.086000 C 04:47:27 Temperature Measurement, Probe Number = 3, T = 20.007000 C 04:47:27 Temperature Measurement, Probe Number = 4, T = 20.059000 C 04:47:28 Temperature Measurement, Probe Number = 5, T = 20.023000 C 04:47:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.09 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:47:28 Integrated Voltage Measurement... 04:47:50 Voltage Offset Correction: v_off_ini = -0.000001669 V, v_off_fin = -0.000000651 V 04:47:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158413073 Vs 04:47:50 Integrated Voltage Measurement... 04:48:17 Voltage Offset Correction: v_off_ini = -0.000002357 V, v_off_fin = -0.000001910 V 04:48:17 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158360647 Vs 04:48:31 Temperature Measurement, Probe Number = 0, T = 19.985000 C 04:48:32 Temperature Measurement, Probe Number = 1, T = 20.065000 C 04:48:32 Temperature Measurement, Probe Number = 2, T = 20.084000 C 04:48:33 Temperature Measurement, Probe Number = 3, T = 20.006000 C 04:48:33 Temperature Measurement, Probe Number = 4, T = 20.060000 C 04:48:34 Temperature Measurement, Probe Number = 5, T = 20.024000 C 04:48:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:48:34 Integrated Voltage Measurement... 04:48:57 Voltage Offset Correction: v_off_ini = -0.000000900 V, v_off_fin = -0.000000476 V 04:48:57 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158396647 Vs 04:48:57 Integrated Voltage Measurement... 04:49:19 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000000966 V 04:49:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379970 Vs 04:49:32 Temperature Measurement, Probe Number = 0, T = 19.960000 C 04:49:33 Temperature Measurement, Probe Number = 1, T = 20.064000 C 04:49:34 Temperature Measurement, Probe Number = 2, T = 20.082000 C 04:49:34 Temperature Measurement, Probe Number = 3, T = 20.005000 C 04:49:35 Temperature Measurement, Probe Number = 4, T = 20.059000 C 04:49:35 Temperature Measurement, Probe Number = 5, T = 20.023000 C 04:49:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:49:35 Integrated Voltage Measurement... 04:49:58 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = 0.000000168 V 04:49:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399005 Vs 04:49:58 Integrated Voltage Measurement... 04:50:20 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000002517 V 04:50:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400638 Vs 04:50:34 Temperature Measurement, Probe Number = 0, T = 19.967000 C 04:50:35 Temperature Measurement, Probe Number = 1, T = 20.062000 C 04:50:35 Temperature Measurement, Probe Number = 2, T = 20.081000 C 04:50:36 Temperature Measurement, Probe Number = 3, T = 20.006000 C 04:50:36 Temperature Measurement, Probe Number = 4, T = 20.058000 C 04:50:37 Temperature Measurement, Probe Number = 5, T = 20.022000 C 04:50:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.02 04:50:37 Integrated Voltage Measurement... 04:50:59 Voltage Offset Correction: v_off_ini = -0.000001068 V, v_off_fin = -0.000000783 V 04:50:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158429039 Vs 04:50:59 Integrated Voltage Measurement... 04:51:21 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000002788 V 04:51:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391604 Vs 05:47:35 Temperature Measurement, Probe Number = 0, T = 19.947000 C 05:47:36 Temperature Measurement, Probe Number = 1, T = 20.045000 C 05:47:36 Temperature Measurement, Probe Number = 2, T = 20.060000 C 05:47:37 Temperature Measurement, Probe Number = 3, T = 19.977000 C 05:47:37 Temperature Measurement, Probe Number = 4, T = 20.040000 C 05:47:38 Temperature Measurement, Probe Number = 5, T = 20.008000 C 05:47:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 05:47:38 Integrated Voltage Measurement... 05:48:00 Voltage Offset Correction: v_off_ini = -0.000000410 V, v_off_fin = 0.000004112 V 05:48:00 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158409137 Vs 05:48:00 Integrated Voltage Measurement... 05:48:22 Voltage Offset Correction: v_off_ini = -0.000001932 V, v_off_fin = -0.000000842 V 05:48:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378489 Vs 05:48:36 Temperature Measurement, Probe Number = 0, T = 19.950000 C 05:48:37 Temperature Measurement, Probe Number = 1, T = 20.048000 C 05:48:37 Temperature Measurement, Probe Number = 2, T = 20.062000 C 05:48:38 Temperature Measurement, Probe Number = 3, T = 19.977000 C 05:48:38 Temperature Measurement, Probe Number = 4, T = 20.038000 C 05:48:39 Temperature Measurement, Probe Number = 5, T = 20.008000 C 05:48:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 05:48:39 Integrated Voltage Measurement... 05:49:01 Voltage Offset Correction: v_off_ini = -0.000002217 V, v_off_fin = -0.000001931 V 05:49:01 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158425156 Vs 05:49:01 Integrated Voltage Measurement... 05:49:23 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000002415 V 05:49:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395807 Vs 05:49:37 Temperature Measurement, Probe Number = 0, T = 19.943000 C 05:49:37 Temperature Measurement, Probe Number = 1, T = 20.045000 C 05:49:38 Temperature Measurement, Probe Number = 2, T = 20.061000 C 05:49:39 Temperature Measurement, Probe Number = 3, T = 19.979000 C 05:49:39 Temperature Measurement, Probe Number = 4, T = 20.037000 C 05:49:40 Temperature Measurement, Probe Number = 5, T = 20.008000 C 05:49:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 05:49:40 Integrated Voltage Measurement... 05:50:02 Voltage Offset Correction: v_off_ini = -0.000002056 V, v_off_fin = -0.000002429 V 05:50:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158434472 Vs 05:50:02 Integrated Voltage Measurement... 05:50:25 Voltage Offset Correction: v_off_ini = -0.000001931 V, v_off_fin = -0.000001112 V 05:50:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392759 Vs 05:50:38 Temperature Measurement, Probe Number = 0, T = 19.930000 C 05:50:39 Temperature Measurement, Probe Number = 1, T = 20.047000 C 05:50:40 Temperature Measurement, Probe Number = 2, T = 20.063000 C 05:50:40 Temperature Measurement, Probe Number = 3, T = 19.976000 C 05:50:41 Temperature Measurement, Probe Number = 4, T = 20.036000 C 05:50:41 Temperature Measurement, Probe Number = 5, T = 20.006000 C 05:50:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 05:50:41 Integrated Voltage Measurement... 05:51:04 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = 0.000001090 V 05:51:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158396042 Vs 05:51:04 Integrated Voltage Measurement... 05:51:29 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000002436 V 05:51:30 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158374900 Vs 05:51:43 Temperature Measurement, Probe Number = 0, T = 19.926000 C 05:51:44 Temperature Measurement, Probe Number = 1, T = 20.043000 C 05:51:44 Temperature Measurement, Probe Number = 2, T = 20.058000 C 05:51:45 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:51:46 Temperature Measurement, Probe Number = 4, T = 20.036000 C 05:51:46 Temperature Measurement, Probe Number = 5, T = 20.005000 C 05:51:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.00 05:51:46 Integrated Voltage Measurement... 05:52:10 Voltage Offset Correction: v_off_ini = 0.000000088 V, v_off_fin = 0.000000600 V 05:52:10 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158392251 Vs 05:52:10 Integrated Voltage Measurement... 05:52:32 Voltage Offset Correction: v_off_ini = 0.000002721 V, v_off_fin = -0.000003072 V 05:52:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423637 Vs 05:52:45 Temperature Measurement, Probe Number = 0, T = 19.919000 C 05:52:46 Temperature Measurement, Probe Number = 1, T = 20.040000 C 05:52:47 Temperature Measurement, Probe Number = 2, T = 20.057000 C 05:52:47 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:52:48 Temperature Measurement, Probe Number = 4, T = 20.033000 C 05:52:48 Temperature Measurement, Probe Number = 5, T = 20.003000 C 05:52:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.00 05:52:48 Integrated Voltage Measurement... 05:53:11 Voltage Offset Correction: v_off_ini = -0.000000476 V, v_off_fin = 0.000000520 V 05:53:11 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158393733 Vs 05:53:11 Integrated Voltage Measurement... 05:53:33 Voltage Offset Correction: v_off_ini = -0.000000776 V, v_off_fin = -0.000002451 V 05:53:33 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158384282 Vs 05:53:46 Temperature Measurement, Probe Number = 0, T = 19.928000 C 05:53:47 Temperature Measurement, Probe Number = 1, T = 20.041000 C 05:53:48 Temperature Measurement, Probe Number = 2, T = 20.056000 C 05:53:48 Temperature Measurement, Probe Number = 3, T = 19.963000 C 05:53:49 Temperature Measurement, Probe Number = 4, T = 20.033000 C 05:53:49 Temperature Measurement, Probe Number = 5, T = 20.005000 C 05:53:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.00 05:53:49 Integrated Voltage Measurement... 05:54:12 Voltage Offset Correction: v_off_ini = -0.000000871 V, v_off_fin = -0.000002422 V 05:54:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158430023 Vs 05:54:12 Integrated Voltage Measurement... 05:54:34 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000003074 V 05:54:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387336 Vs 05:54:48 Temperature Measurement, Probe Number = 0, T = 19.895000 C 05:54:48 Temperature Measurement, Probe Number = 1, T = 20.041000 C 05:54:49 Temperature Measurement, Probe Number = 2, T = 20.058000 C 05:54:50 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:54:50 Temperature Measurement, Probe Number = 4, T = 20.034000 C 05:54:51 Temperature Measurement, Probe Number = 5, T = 20.004000 C 05:54:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.00 05:54:51 Integrated Voltage Measurement... 05:55:13 Voltage Offset Correction: v_off_ini = -0.000001961 V, v_off_fin = -0.000000219 V 05:55:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414663 Vs 05:55:13 Integrated Voltage Measurement... 05:55:36 Voltage Offset Correction: v_off_ini = 0.000000051 V, v_off_fin = -0.000001383 V 05:55:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402943 Vs 05:55:49 Temperature Measurement, Probe Number = 0, T = 19.925000 C 05:55:50 Temperature Measurement, Probe Number = 1, T = 20.040000 C 05:55:50 Temperature Measurement, Probe Number = 2, T = 20.062000 C 05:55:51 Temperature Measurement, Probe Number = 3, T = 19.963000 C 05:55:52 Temperature Measurement, Probe Number = 4, T = 20.036000 C 05:55:52 Temperature Measurement, Probe Number = 5, T = 20.004000 C 05:55:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.00 05:55:52 Integrated Voltage Measurement... 05:56:15 Voltage Offset Correction: v_off_ini = -0.000002034 V, v_off_fin = -0.000000146 V 05:56:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158417993 Vs 05:56:15 Integrated Voltage Measurement... 05:56:37 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000000629 V 05:56:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385760 Vs 05:56:51 Temperature Measurement, Probe Number = 0, T = 19.920000 C 05:56:51 Temperature Measurement, Probe Number = 1, T = 20.041000 C 05:56:52 Temperature Measurement, Probe Number = 2, T = 20.058000 C 05:56:53 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:56:53 Temperature Measurement, Probe Number = 4, T = 20.034000 C 05:56:54 Temperature Measurement, Probe Number = 5, T = 20.003000 C 05:56:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.00 05:56:54 Integrated Voltage Measurement... 05:57:16 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000003102 V 05:57:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422467 Vs 05:57:16 Integrated Voltage Measurement... 05:57:39 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000002560 V 05:57:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387726 Vs 06:53:53 Temperature Measurement, Probe Number = 0, T = 19.892000 C 06:53:53 Temperature Measurement, Probe Number = 1, T = 20.041000 C 06:53:54 Temperature Measurement, Probe Number = 2, T = 20.045000 C 06:53:55 Temperature Measurement, Probe Number = 3, T = 19.966000 C 06:53:55 Temperature Measurement, Probe Number = 4, T = 20.025000 C 06:53:56 Temperature Measurement, Probe Number = 5, T = 20.003000 C 06:53:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:53:56 Integrated Voltage Measurement... 06:54:18 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = 0.000001976 V 06:54:18 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.158451592 Vs 06:54:18 Integrated Voltage Measurement... 06:54:40 Voltage Offset Correction: v_off_ini = -0.000000681 V, v_off_fin = -0.000001808 V 06:54:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387261 Vs 06:54:54 Temperature Measurement, Probe Number = 0, T = 19.894000 C 06:54:54 Temperature Measurement, Probe Number = 1, T = 20.036000 C 06:54:55 Temperature Measurement, Probe Number = 2, T = 20.044000 C 06:54:56 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:54:56 Temperature Measurement, Probe Number = 4, T = 20.024000 C 06:54:57 Temperature Measurement, Probe Number = 5, T = 20.001000 C 06:54:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:54:57 Integrated Voltage Measurement... 06:55:19 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000000263 V 06:55:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158394429 Vs 06:55:19 Integrated Voltage Measurement... 06:55:42 Voltage Offset Correction: v_off_ini = 0.000000051 V, v_off_fin = -0.000001800 V 06:55:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389659 Vs 06:55:55 Temperature Measurement, Probe Number = 0, T = 19.882000 C 06:55:56 Temperature Measurement, Probe Number = 1, T = 20.038000 C 06:55:57 Temperature Measurement, Probe Number = 2, T = 20.046000 C 06:55:57 Temperature Measurement, Probe Number = 3, T = 19.966000 C 06:55:58 Temperature Measurement, Probe Number = 4, T = 20.024000 C 06:55:58 Temperature Measurement, Probe Number = 5, T = 20.002000 C 06:55:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:55:58 Integrated Voltage Measurement... 06:56:21 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = 0.000000000 V 06:56:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410487 Vs 06:56:21 Integrated Voltage Measurement... 06:56:43 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000002313 V 06:56:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391150 Vs 06:56:57 Temperature Measurement, Probe Number = 0, T = 19.909000 C 06:56:58 Temperature Measurement, Probe Number = 1, T = 20.035000 C 06:56:59 Temperature Measurement, Probe Number = 2, T = 20.041000 C 06:56:59 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:57:00 Temperature Measurement, Probe Number = 4, T = 20.024000 C 06:57:00 Temperature Measurement, Probe Number = 5, T = 20.000000 C 06:57:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:57:00 Integrated Voltage Measurement... 06:57:23 Voltage Offset Correction: v_off_ini = -0.000001076 V, v_off_fin = -0.000000234 V 06:57:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158397617 Vs 06:57:23 Integrated Voltage Measurement... 06:57:45 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = -0.000003286 V 06:57:45 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158400875 Vs 06:57:59 Temperature Measurement, Probe Number = 0, T = 19.881000 C 06:57:59 Temperature Measurement, Probe Number = 1, T = 20.034000 C 06:58:00 Temperature Measurement, Probe Number = 2, T = 20.043000 C 06:58:01 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:58:01 Temperature Measurement, Probe Number = 4, T = 20.024000 C 06:58:02 Temperature Measurement, Probe Number = 5, T = 19.999000 C 06:58:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:58:02 Integrated Voltage Measurement... 06:58:24 Voltage Offset Correction: v_off_ini = -0.000001420 V, v_off_fin = -0.000001303 V 06:58:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418337 Vs 06:58:24 Integrated Voltage Measurement... 06:58:47 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000002401 V 06:58:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390589 Vs 06:59:00 Temperature Measurement, Probe Number = 0, T = 19.842000 C 06:59:01 Temperature Measurement, Probe Number = 1, T = 20.034000 C 06:59:01 Temperature Measurement, Probe Number = 2, T = 20.043000 C 06:59:02 Temperature Measurement, Probe Number = 3, T = 19.966000 C 06:59:03 Temperature Measurement, Probe Number = 4, T = 20.023000 C 06:59:03 Temperature Measurement, Probe Number = 5, T = 19.999000 C 06:59:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 06:59:03 Integrated Voltage Measurement... 06:59:25 Voltage Offset Correction: v_off_ini = -0.000001859 V, v_off_fin = -0.000001061 V 06:59:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158413530 Vs 06:59:25 Integrated Voltage Measurement... 06:59:48 Voltage Offset Correction: v_off_ini = -0.000000395 V, v_off_fin = -0.000001991 V 06:59:48 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158392644 Vs 07:00:01 Temperature Measurement, Probe Number = 0, T = 19.853000 C 07:00:02 Temperature Measurement, Probe Number = 1, T = 20.039000 C 07:00:02 Temperature Measurement, Probe Number = 2, T = 20.045000 C 07:00:03 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:00:04 Temperature Measurement, Probe Number = 4, T = 20.023000 C 07:00:04 Temperature Measurement, Probe Number = 5, T = 20.001000 C 07:00:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 07:00:04 Integrated Voltage Measurement... 07:00:26 Voltage Offset Correction: v_off_ini = -0.000001734 V, v_off_fin = 0.000000263 V 07:00:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158409839 Vs 07:00:26 Integrated Voltage Measurement... 07:00:48 Voltage Offset Correction: v_off_ini = -0.000000293 V, v_off_fin = -0.000001544 V 07:00:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390572 Vs 07:01:02 Temperature Measurement, Probe Number = 0, T = 19.841000 C 07:01:03 Temperature Measurement, Probe Number = 1, T = 20.036000 C 07:01:03 Temperature Measurement, Probe Number = 2, T = 20.043000 C 07:01:04 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:01:04 Temperature Measurement, Probe Number = 4, T = 20.022000 C 07:01:05 Temperature Measurement, Probe Number = 5, T = 20.000000 C 07:01:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 07:01:05 Integrated Voltage Measurement... 07:01:27 Voltage Offset Correction: v_off_ini = -0.000002422 V, v_off_fin = -0.000002371 V 07:01:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158419302 Vs 07:01:27 Integrated Voltage Measurement... 07:01:49 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = -0.000001229 V 07:01:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390990 Vs 07:02:03 Temperature Measurement, Probe Number = 0, T = 19.825000 C 07:02:04 Temperature Measurement, Probe Number = 1, T = 20.040000 C 07:02:04 Temperature Measurement, Probe Number = 2, T = 20.044000 C 07:02:05 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:02:05 Temperature Measurement, Probe Number = 4, T = 20.021000 C 07:02:06 Temperature Measurement, Probe Number = 5, T = 20.002000 C 07:02:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 07:02:06 Integrated Voltage Measurement... 07:02:28 Voltage Offset Correction: v_off_ini = -0.000002217 V, v_off_fin = -0.000000512 V 07:02:28 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158412665 Vs 07:02:28 Integrated Voltage Measurement... 07:02:50 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000003014 V 07:02:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393702 Vs 07:03:04 Temperature Measurement, Probe Number = 0, T = 19.819000 C 07:03:05 Temperature Measurement, Probe Number = 1, T = 20.036000 C 07:03:05 Temperature Measurement, Probe Number = 2, T = 20.041000 C 07:03:06 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:03:06 Temperature Measurement, Probe Number = 4, T = 20.022000 C 07:03:07 Temperature Measurement, Probe Number = 5, T = 20.001000 C 07:03:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 07:03:07 Integrated Voltage Measurement... 07:03:29 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = -0.000000146 V 07:03:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158423307 Vs 07:03:29 Integrated Voltage Measurement... 07:03:51 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000002751 V 07:03:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392784 Vs 08:00:05 Temperature Measurement, Probe Number = 0, T = 19.970000 C 08:00:06 Temperature Measurement, Probe Number = 1, T = 20.033000 C 08:00:06 Temperature Measurement, Probe Number = 2, T = 20.035000 C 08:00:07 Temperature Measurement, Probe Number = 3, T = 19.963000 C 08:00:07 Temperature Measurement, Probe Number = 4, T = 20.012000 C 08:00:08 Temperature Measurement, Probe Number = 5, T = 19.994000 C 08:00:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:00:08 Integrated Voltage Measurement... 08:00:30 Voltage Offset Correction: v_off_ini = -0.000004288 V, v_off_fin = -0.000001061 V 08:00:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.158476986 Vs 08:00:31 Integrated Voltage Measurement... 08:00:53 Voltage Offset Correction: v_off_ini = 0.000002195 V, v_off_fin = -0.000002254 V 08:00:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435660 Vs 08:01:07 Temperature Measurement, Probe Number = 0, T = 19.983000 C 08:01:07 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:01:08 Temperature Measurement, Probe Number = 2, T = 20.037000 C 08:01:09 Temperature Measurement, Probe Number = 3, T = 19.963000 C 08:01:09 Temperature Measurement, Probe Number = 4, T = 20.013000 C 08:01:10 Temperature Measurement, Probe Number = 5, T = 19.995000 C 08:01:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 08:01:10 Integrated Voltage Measurement... 08:01:32 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000000498 V 08:01:33 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158412365 Vs 08:01:33 Integrated Voltage Measurement... 08:01:55 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = 0.000000263 V 08:01:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385456 Vs 08:02:09 Temperature Measurement, Probe Number = 0, T = 19.978000 C 08:02:09 Temperature Measurement, Probe Number = 1, T = 20.031000 C 08:02:10 Temperature Measurement, Probe Number = 2, T = 20.037000 C 08:02:11 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:02:11 Temperature Measurement, Probe Number = 4, T = 20.013000 C 08:02:12 Temperature Measurement, Probe Number = 5, T = 19.994000 C 08:02:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:02:12 Integrated Voltage Measurement... 08:02:34 Voltage Offset Correction: v_off_ini = -0.000001478 V, v_off_fin = -0.000000315 V 08:02:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411026 Vs 08:02:34 Integrated Voltage Measurement... 08:02:56 Voltage Offset Correction: v_off_ini = -0.000000190 V, v_off_fin = -0.000002605 V 08:02:56 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158401166 Vs 08:03:10 Temperature Measurement, Probe Number = 0, T = 19.976000 C 08:03:10 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:03:11 Temperature Measurement, Probe Number = 2, T = 20.038000 C 08:03:12 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:03:12 Temperature Measurement, Probe Number = 4, T = 20.013000 C 08:03:13 Temperature Measurement, Probe Number = 5, T = 19.993000 C 08:03:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:03:13 Integrated Voltage Measurement... 08:03:36 Voltage Offset Correction: v_off_ini = -0.000002407 V, v_off_fin = -0.000001229 V 08:03:36 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158425394 Vs 08:03:36 Integrated Voltage Measurement... 08:03:58 Voltage Offset Correction: v_off_ini = 0.000000183 V, v_off_fin = -0.000002546 V 08:03:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404288 Vs 08:04:12 Temperature Measurement, Probe Number = 0, T = 19.964000 C 08:04:12 Temperature Measurement, Probe Number = 1, T = 20.035000 C 08:04:13 Temperature Measurement, Probe Number = 2, T = 20.040000 C 08:04:14 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:04:14 Temperature Measurement, Probe Number = 4, T = 20.014000 C 08:04:15 Temperature Measurement, Probe Number = 5, T = 19.993000 C 08:04:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:04:15 Integrated Voltage Measurement... 08:04:37 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000001610 V 08:04:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420944 Vs 08:04:37 Integrated Voltage Measurement... 08:05:00 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000002956 V 08:05:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381173 Vs 08:05:13 Temperature Measurement, Probe Number = 0, T = 19.954000 C 08:05:14 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:05:14 Temperature Measurement, Probe Number = 2, T = 20.035000 C 08:05:15 Temperature Measurement, Probe Number = 3, T = 19.962000 C 08:05:16 Temperature Measurement, Probe Number = 4, T = 20.013000 C 08:05:16 Temperature Measurement, Probe Number = 5, T = 19.993000 C 08:05:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:05:16 Integrated Voltage Measurement... 08:05:38 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000001032 V 08:05:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405206 Vs 08:05:38 Integrated Voltage Measurement... 08:06:01 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000003191 V 08:06:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386933 Vs 08:06:15 Temperature Measurement, Probe Number = 0, T = 19.972000 C 08:06:15 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:06:16 Temperature Measurement, Probe Number = 2, T = 20.035000 C 08:06:17 Temperature Measurement, Probe Number = 3, T = 19.965000 C 08:06:17 Temperature Measurement, Probe Number = 4, T = 20.014000 C 08:06:18 Temperature Measurement, Probe Number = 5, T = 19.993000 C 08:06:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:06:18 Integrated Voltage Measurement... 08:06:40 Voltage Offset Correction: v_off_ini = -0.000000827 V, v_off_fin = 0.000000344 V 08:06:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403138 Vs 08:06:40 Integrated Voltage Measurement... 08:07:02 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002591 V 08:07:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383709 Vs 08:07:16 Temperature Measurement, Probe Number = 0, T = 19.946000 C 08:07:16 Temperature Measurement, Probe Number = 1, T = 20.029000 C 08:07:17 Temperature Measurement, Probe Number = 2, T = 20.033000 C 08:07:18 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:07:18 Temperature Measurement, Probe Number = 4, T = 20.012000 C 08:07:19 Temperature Measurement, Probe Number = 5, T = 19.992000 C 08:07:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:07:19 Integrated Voltage Measurement... 08:07:41 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = -0.000000029 V 08:07:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158404227 Vs 08:07:41 Integrated Voltage Measurement... 08:08:03 Voltage Offset Correction: v_off_ini = -0.000001369 V, v_off_fin = -0.000003806 V 08:08:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379336 Vs 08:08:17 Temperature Measurement, Probe Number = 0, T = 19.943000 C 08:08:17 Temperature Measurement, Probe Number = 1, T = 20.031000 C 08:08:18 Temperature Measurement, Probe Number = 2, T = 20.034000 C 08:08:19 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:08:19 Temperature Measurement, Probe Number = 4, T = 20.012000 C 08:08:20 Temperature Measurement, Probe Number = 5, T = 19.993000 C 08:08:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:08:20 Integrated Voltage Measurement... 08:08:42 Voltage Offset Correction: v_off_ini = -0.000000359 V, v_off_fin = 0.000000849 V 08:08:42 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158406552 Vs 08:08:42 Integrated Voltage Measurement... 08:09:04 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000002379 V 08:09:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394476 Vs 08:09:18 Temperature Measurement, Probe Number = 0, T = 19.915000 C 08:09:19 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:09:19 Temperature Measurement, Probe Number = 2, T = 20.036000 C 08:09:20 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:09:20 Temperature Measurement, Probe Number = 4, T = 20.012000 C 08:09:21 Temperature Measurement, Probe Number = 5, T = 19.992000 C 08:09:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 08:09:21 Integrated Voltage Measurement... 08:09:43 Voltage Offset Correction: v_off_ini = -0.000001888 V, v_off_fin = -0.000001991 V 08:09:43 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158429848 Vs 08:09:43 Integrated Voltage Measurement... 08:10:05 Voltage Offset Correction: v_off_ini = 0.000000124 V, v_off_fin = -0.000002488 V 08:10:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393724 Vs 09:06:19 Temperature Measurement, Probe Number = 0, T = 20.079000 C 09:06:20 Temperature Measurement, Probe Number = 1, T = 20.040000 C 09:06:20 Temperature Measurement, Probe Number = 2, T = 20.043000 C 09:06:21 Temperature Measurement, Probe Number = 3, T = 19.977000 C 09:06:21 Temperature Measurement, Probe Number = 4, T = 20.018000 C 09:06:22 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:06:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:06:22 Integrated Voltage Measurement... 09:06:45 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000000681 V 09:06:45 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158484366 Vs 09:06:45 Integrated Voltage Measurement... 09:07:07 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000001998 V 09:07:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400380 Vs 09:07:20 Temperature Measurement, Probe Number = 0, T = 20.065000 C 09:07:21 Temperature Measurement, Probe Number = 1, T = 20.043000 C 09:07:22 Temperature Measurement, Probe Number = 2, T = 20.046000 C 09:07:22 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:07:23 Temperature Measurement, Probe Number = 4, T = 20.018000 C 09:07:23 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:07:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:07:23 Integrated Voltage Measurement... 09:07:46 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002986 V 09:07:46 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158419294 Vs 09:07:46 Integrated Voltage Measurement... 09:08:08 Voltage Offset Correction: v_off_ini = 0.000001259 V, v_off_fin = -0.000001529 V 09:08:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158411745 Vs 09:08:22 Temperature Measurement, Probe Number = 0, T = 20.051000 C 09:08:22 Temperature Measurement, Probe Number = 1, T = 20.044000 C 09:08:23 Temperature Measurement, Probe Number = 2, T = 20.046000 C 09:08:24 Temperature Measurement, Probe Number = 3, T = 19.976000 C 09:08:24 Temperature Measurement, Probe Number = 4, T = 20.018000 C 09:08:25 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:08:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:08:25 Integrated Voltage Measurement... 09:08:47 Voltage Offset Correction: v_off_ini = -0.000000586 V, v_off_fin = 0.000000754 V 09:08:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158404974 Vs 09:08:47 Integrated Voltage Measurement... 09:09:09 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000002971 V 09:09:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158416072 Vs 09:09:23 Temperature Measurement, Probe Number = 0, T = 20.034000 C 09:09:23 Temperature Measurement, Probe Number = 1, T = 20.044000 C 09:09:24 Temperature Measurement, Probe Number = 2, T = 20.045000 C 09:09:25 Temperature Measurement, Probe Number = 3, T = 19.977000 C 09:09:25 Temperature Measurement, Probe Number = 4, T = 20.018000 C 09:09:26 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:09:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:09:26 Integrated Voltage Measurement... 09:09:48 Voltage Offset Correction: v_off_ini = -0.000002591 V, v_off_fin = -0.000001676 V 09:09:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158434226 Vs 09:09:48 Integrated Voltage Measurement... 09:10:10 Voltage Offset Correction: v_off_ini = -0.000002225 V, v_off_fin = -0.000003367 V 09:10:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392274 Vs 09:10:24 Temperature Measurement, Probe Number = 0, T = 20.049000 C 09:10:25 Temperature Measurement, Probe Number = 1, T = 20.045000 C 09:10:25 Temperature Measurement, Probe Number = 2, T = 20.046000 C 09:10:26 Temperature Measurement, Probe Number = 3, T = 19.977000 C 09:10:27 Temperature Measurement, Probe Number = 4, T = 20.019000 C 09:10:27 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:10:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:10:27 Integrated Voltage Measurement... 09:10:49 Voltage Offset Correction: v_off_ini = -0.000002459 V, v_off_fin = -0.000003373 V 09:10:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158432081 Vs 09:10:50 Integrated Voltage Measurement... 09:11:12 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000000805 V 09:11:12 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158395783 Vs 09:11:26 Temperature Measurement, Probe Number = 0, T = 20.048000 C 09:11:26 Temperature Measurement, Probe Number = 1, T = 20.043000 C 09:11:27 Temperature Measurement, Probe Number = 2, T = 20.046000 C 09:11:27 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:11:28 Temperature Measurement, Probe Number = 4, T = 20.019000 C 09:11:29 Temperature Measurement, Probe Number = 5, T = 19.999000 C 09:11:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:11:29 Integrated Voltage Measurement... 09:11:51 Voltage Offset Correction: v_off_ini = -0.000001998 V, v_off_fin = -0.000001990 V 09:11:51 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158432425 Vs 09:11:51 Integrated Voltage Measurement... 09:12:13 Voltage Offset Correction: v_off_ini = -0.000000908 V, v_off_fin = -0.000001552 V 09:12:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389856 Vs 09:12:27 Temperature Measurement, Probe Number = 0, T = 20.032000 C 09:12:27 Temperature Measurement, Probe Number = 1, T = 20.042000 C 09:12:28 Temperature Measurement, Probe Number = 2, T = 20.043000 C 09:12:28 Temperature Measurement, Probe Number = 3, T = 19.978000 C 09:12:29 Temperature Measurement, Probe Number = 4, T = 20.017000 C 09:12:30 Temperature Measurement, Probe Number = 5, T = 19.998000 C 09:12:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:12:30 Integrated Voltage Measurement... 09:12:52 Voltage Offset Correction: v_off_ini = -0.000002005 V, v_off_fin = -0.000000966 V 09:12:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158411068 Vs 09:12:52 Integrated Voltage Measurement... 09:13:14 Voltage Offset Correction: v_off_ini = 0.000001639 V, v_off_fin = -0.000003454 V 09:13:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425930 Vs 09:13:28 Temperature Measurement, Probe Number = 0, T = 20.036000 C 09:13:28 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:13:29 Temperature Measurement, Probe Number = 2, T = 20.043000 C 09:13:29 Temperature Measurement, Probe Number = 3, T = 19.980000 C 09:13:30 Temperature Measurement, Probe Number = 4, T = 20.017000 C 09:13:31 Temperature Measurement, Probe Number = 5, T = 19.997000 C 09:13:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:13:31 Integrated Voltage Measurement... 09:13:53 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = 0.000001932 V 09:13:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400217 Vs 09:13:53 Integrated Voltage Measurement... 09:14:16 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000001983 V 09:14:16 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158404660 Vs 09:14:29 Temperature Measurement, Probe Number = 0, T = 20.029000 C 09:14:30 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:14:30 Temperature Measurement, Probe Number = 2, T = 20.043000 C 09:14:31 Temperature Measurement, Probe Number = 3, T = 19.981000 C 09:14:32 Temperature Measurement, Probe Number = 4, T = 20.017000 C 09:14:32 Temperature Measurement, Probe Number = 5, T = 19.997000 C 09:14:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:14:32 Integrated Voltage Measurement... 09:14:54 Voltage Offset Correction: v_off_ini = -0.000001932 V, v_off_fin = -0.000000915 V 09:14:55 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158425462 Vs 09:14:55 Integrated Voltage Measurement... 09:15:17 Voltage Offset Correction: v_off_ini = 0.000000285 V, v_off_fin = -0.000002781 V 09:15:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389686 Vs 09:15:31 Temperature Measurement, Probe Number = 0, T = 20.029000 C 09:15:31 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:15:32 Temperature Measurement, Probe Number = 2, T = 20.044000 C 09:15:32 Temperature Measurement, Probe Number = 3, T = 19.982000 C 09:15:33 Temperature Measurement, Probe Number = 4, T = 20.018000 C 09:15:34 Temperature Measurement, Probe Number = 5, T = 19.997000 C 09:15:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 09:15:34 Integrated Voltage Measurement... 09:15:56 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = -0.000000066 V 09:15:56 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420442 Vs 09:15:56 Integrated Voltage Measurement... 09:16:18 Voltage Offset Correction: v_off_ini = -0.000000227 V, v_off_fin = -0.000001215 V 09:16:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396936 Vs 10:12:32 Temperature Measurement, Probe Number = 0, T = 20.302000 C 10:12:32 Temperature Measurement, Probe Number = 1, T = 20.063000 C 10:12:33 Temperature Measurement, Probe Number = 2, T = 20.066000 C 10:12:34 Temperature Measurement, Probe Number = 3, T = 20.039000 C 10:12:34 Temperature Measurement, Probe Number = 4, T = 20.040000 C 10:12:35 Temperature Measurement, Probe Number = 5, T = 20.018000 C 10:12:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:12:35 Integrated Voltage Measurement... 10:12:57 Voltage Offset Correction: v_off_ini = -0.000000190 V, v_off_fin = -0.000001243 V 10:12:57 Integrated Voltage Measurement Delta Gap = 0.0040024 m VT = 0.158493556 Vs 10:12:57 Integrated Voltage Measurement... 10:13:20 Voltage Offset Correction: v_off_ini = -0.000000080 V, v_off_fin = -0.000001024 V 10:13:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384892 Vs 10:13:33 Temperature Measurement, Probe Number = 0, T = 20.316000 C 10:13:34 Temperature Measurement, Probe Number = 1, T = 20.066000 C 10:13:35 Temperature Measurement, Probe Number = 2, T = 20.069000 C 10:13:35 Temperature Measurement, Probe Number = 3, T = 20.035000 C 10:13:36 Temperature Measurement, Probe Number = 4, T = 20.041000 C 10:13:37 Temperature Measurement, Probe Number = 5, T = 20.020000 C 10:13:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:13:37 Integrated Voltage Measurement... 10:13:59 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000000636 V 10:13:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158402947 Vs 10:13:59 Integrated Voltage Measurement... 10:14:21 Voltage Offset Correction: v_off_ini = -0.000000709 V, v_off_fin = -0.000001609 V 10:14:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394107 Vs 10:14:35 Temperature Measurement, Probe Number = 0, T = 20.317000 C 10:14:36 Temperature Measurement, Probe Number = 1, T = 20.068000 C 10:14:36 Temperature Measurement, Probe Number = 2, T = 20.072000 C 10:14:37 Temperature Measurement, Probe Number = 3, T = 20.034000 C 10:14:38 Temperature Measurement, Probe Number = 4, T = 20.043000 C 10:14:38 Temperature Measurement, Probe Number = 5, T = 20.021000 C 10:14:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:14:38 Integrated Voltage Measurement... 10:15:01 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000001828 V 10:15:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158429738 Vs 10:15:01 Integrated Voltage Measurement... 10:15:23 Voltage Offset Correction: v_off_ini = 0.000001075 V, v_off_fin = -0.000003160 V 10:15:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399198 Vs 10:15:37 Temperature Measurement, Probe Number = 0, T = 20.319000 C 10:15:37 Temperature Measurement, Probe Number = 1, T = 20.068000 C 10:15:38 Temperature Measurement, Probe Number = 2, T = 20.074000 C 10:15:38 Temperature Measurement, Probe Number = 3, T = 20.034000 C 10:15:39 Temperature Measurement, Probe Number = 4, T = 20.043000 C 10:15:40 Temperature Measurement, Probe Number = 5, T = 20.021000 C 10:15:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:15:40 Integrated Voltage Measurement... 10:16:02 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = 0.000008366 V 10:16:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158351700 Vs 10:16:02 Integrated Voltage Measurement... 10:16:24 Voltage Offset Correction: v_off_ini = -0.000005155 V, v_off_fin = -0.000001697 V 10:16:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158355250 Vs 10:16:38 Temperature Measurement, Probe Number = 0, T = 20.298000 C 10:16:38 Temperature Measurement, Probe Number = 1, T = 20.069000 C 10:16:39 Temperature Measurement, Probe Number = 2, T = 20.075000 C 10:16:40 Temperature Measurement, Probe Number = 3, T = 20.032000 C 10:16:40 Temperature Measurement, Probe Number = 4, T = 20.044000 C 10:16:41 Temperature Measurement, Probe Number = 5, T = 20.022000 C 10:16:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:16:41 Integrated Voltage Measurement... 10:17:03 Voltage Offset Correction: v_off_ini = -0.000001521 V, v_off_fin = 0.000000029 V 10:17:03 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158418966 Vs 10:17:03 Integrated Voltage Measurement... 10:17:25 Voltage Offset Correction: v_off_ini = -0.000001872 V, v_off_fin = -0.000001360 V 10:17:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387661 Vs 10:17:39 Temperature Measurement, Probe Number = 0, T = 20.273000 C 10:17:39 Temperature Measurement, Probe Number = 1, T = 20.068000 C 10:17:40 Temperature Measurement, Probe Number = 2, T = 20.072000 C 10:17:41 Temperature Measurement, Probe Number = 3, T = 20.031000 C 10:17:41 Temperature Measurement, Probe Number = 4, T = 20.043000 C 10:17:42 Temperature Measurement, Probe Number = 5, T = 20.021000 C 10:17:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:17:42 Integrated Voltage Measurement... 10:18:04 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000000146 V 10:18:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402707 Vs 10:18:04 Integrated Voltage Measurement... 10:18:26 Voltage Offset Correction: v_off_ini = -0.000000256 V, v_off_fin = -0.000001682 V 10:18:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381233 Vs 10:18:40 Temperature Measurement, Probe Number = 0, T = 20.238000 C 10:18:40 Temperature Measurement, Probe Number = 1, T = 20.064000 C 10:18:41 Temperature Measurement, Probe Number = 2, T = 20.068000 C 10:18:42 Temperature Measurement, Probe Number = 3, T = 20.032000 C 10:18:42 Temperature Measurement, Probe Number = 4, T = 20.042000 C 10:18:43 Temperature Measurement, Probe Number = 5, T = 20.019000 C 10:18:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:18:43 Integrated Voltage Measurement... 10:19:05 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = -0.000000585 V 10:19:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403687 Vs 10:19:05 Integrated Voltage Measurement... 10:19:28 Voltage Offset Correction: v_off_ini = 0.000000029 V, v_off_fin = -0.000002077 V 10:19:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391255 Vs 10:19:42 Temperature Measurement, Probe Number = 0, T = 20.216000 C 10:19:42 Temperature Measurement, Probe Number = 1, T = 20.063000 C 10:19:43 Temperature Measurement, Probe Number = 2, T = 20.067000 C 10:19:44 Temperature Measurement, Probe Number = 3, T = 20.032000 C 10:19:44 Temperature Measurement, Probe Number = 4, T = 20.041000 C 10:19:45 Temperature Measurement, Probe Number = 5, T = 20.019000 C 10:19:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.22 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:19:45 Integrated Voltage Measurement... 10:20:07 Voltage Offset Correction: v_off_ini = -0.000001382 V, v_off_fin = -0.000001543 V 10:20:07 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158397130 Vs 10:20:07 Integrated Voltage Measurement... 10:20:30 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = -0.000001938 V 10:20:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386900 Vs 10:20:44 Temperature Measurement, Probe Number = 0, T = 20.241000 C 10:20:44 Temperature Measurement, Probe Number = 1, T = 20.066000 C 10:20:45 Temperature Measurement, Probe Number = 2, T = 20.069000 C 10:20:46 Temperature Measurement, Probe Number = 3, T = 20.034000 C 10:20:46 Temperature Measurement, Probe Number = 4, T = 20.043000 C 10:20:47 Temperature Measurement, Probe Number = 5, T = 20.021000 C 10:20:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:20:47 Integrated Voltage Measurement... 10:21:09 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000001258 V 10:21:09 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158412824 Vs 10:21:09 Integrated Voltage Measurement... 10:21:31 Voltage Offset Correction: v_off_ini = -0.000000826 V, v_off_fin = 0.000000848 V 10:21:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400034 Vs 10:21:45 Temperature Measurement, Probe Number = 0, T = 20.275000 C 10:21:45 Temperature Measurement, Probe Number = 1, T = 20.066000 C 10:21:46 Temperature Measurement, Probe Number = 2, T = 20.070000 C 10:21:47 Temperature Measurement, Probe Number = 3, T = 20.044000 C 10:21:47 Temperature Measurement, Probe Number = 4, T = 20.043000 C 10:21:48 Temperature Measurement, Probe Number = 5, T = 20.022000 C 10:21:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 10:21:48 Integrated Voltage Measurement... 10:22:10 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = 0.000000870 V 10:22:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158394963 Vs 10:22:10 Integrated Voltage Measurement... 10:22:33 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000003130 V 10:22:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370807 Vs 11:18:46 Temperature Measurement, Probe Number = 0, T = 20.287000 C 11:18:47 Temperature Measurement, Probe Number = 1, T = 20.090000 C 11:18:47 Temperature Measurement, Probe Number = 2, T = 20.098000 C 11:18:48 Temperature Measurement, Probe Number = 3, T = 20.062000 C 11:18:49 Temperature Measurement, Probe Number = 4, T = 20.072000 C 11:18:49 Temperature Measurement, Probe Number = 5, T = 20.044000 C 11:18:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.04 11:18:49 Integrated Voltage Measurement... 11:19:11 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = 0.000002502 V 11:19:11 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158436030 Vs 11:19:11 Integrated Voltage Measurement... 11:19:34 Voltage Offset Correction: v_off_ini = 0.000001346 V, v_off_fin = -0.000004806 V 11:19:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385600 Vs 11:19:47 Temperature Measurement, Probe Number = 0, T = 20.287000 C 11:19:48 Temperature Measurement, Probe Number = 1, T = 20.091000 C 11:19:48 Temperature Measurement, Probe Number = 2, T = 20.101000 C 11:19:49 Temperature Measurement, Probe Number = 3, T = 20.061000 C 11:19:50 Temperature Measurement, Probe Number = 4, T = 20.073000 C 11:19:50 Temperature Measurement, Probe Number = 5, T = 20.045000 C 11:19:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:19:50 Integrated Voltage Measurement... 11:20:12 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = 0.000001083 V 11:20:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158377973 Vs 11:20:13 Integrated Voltage Measurement... 11:20:35 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000001654 V 11:20:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415758 Vs 11:20:49 Temperature Measurement, Probe Number = 0, T = 20.308000 C 11:20:49 Temperature Measurement, Probe Number = 1, T = 20.092000 C 11:20:50 Temperature Measurement, Probe Number = 2, T = 20.102000 C 11:20:51 Temperature Measurement, Probe Number = 3, T = 20.063000 C 11:20:51 Temperature Measurement, Probe Number = 4, T = 20.073000 C 11:20:52 Temperature Measurement, Probe Number = 5, T = 20.045000 C 11:20:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:20:52 Integrated Voltage Measurement... 11:21:14 Voltage Offset Correction: v_off_ini = -0.000001968 V, v_off_fin = -0.000000768 V 11:21:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418596 Vs 11:21:14 Integrated Voltage Measurement... 11:21:36 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000002802 V 11:21:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364687 Vs 11:21:50 Temperature Measurement, Probe Number = 0, T = 20.349000 C 11:21:50 Temperature Measurement, Probe Number = 1, T = 20.092000 C 11:21:51 Temperature Measurement, Probe Number = 2, T = 20.101000 C 11:21:52 Temperature Measurement, Probe Number = 3, T = 20.064000 C 11:21:52 Temperature Measurement, Probe Number = 4, T = 20.074000 C 11:21:53 Temperature Measurement, Probe Number = 5, T = 20.045000 C 11:21:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:21:53 Integrated Voltage Measurement... 11:22:15 Voltage Offset Correction: v_off_ini = -0.000001485 V, v_off_fin = -0.000001243 V 11:22:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408962 Vs 11:22:15 Integrated Voltage Measurement... 11:22:37 Voltage Offset Correction: v_off_ini = -0.000001755 V, v_off_fin = -0.000003342 V 11:22:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369287 Vs 11:22:51 Temperature Measurement, Probe Number = 0, T = 20.352000 C 11:22:52 Temperature Measurement, Probe Number = 1, T = 20.094000 C 11:22:52 Temperature Measurement, Probe Number = 2, T = 20.102000 C 11:22:53 Temperature Measurement, Probe Number = 3, T = 20.065000 C 11:22:53 Temperature Measurement, Probe Number = 4, T = 20.074000 C 11:22:54 Temperature Measurement, Probe Number = 5, T = 20.046000 C 11:22:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.35 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:22:54 Integrated Voltage Measurement... 11:23:16 Voltage Offset Correction: v_off_ini = -0.000002049 V, v_off_fin = -0.000001544 V 11:23:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411240 Vs 11:23:16 Integrated Voltage Measurement... 11:23:38 Voltage Offset Correction: v_off_ini = -0.000001645 V, v_off_fin = -0.000000965 V 11:23:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373380 Vs 11:23:52 Temperature Measurement, Probe Number = 0, T = 20.343000 C 11:23:53 Temperature Measurement, Probe Number = 1, T = 20.093000 C 11:23:53 Temperature Measurement, Probe Number = 2, T = 20.103000 C 11:23:54 Temperature Measurement, Probe Number = 3, T = 20.066000 C 11:23:54 Temperature Measurement, Probe Number = 4, T = 20.074000 C 11:23:55 Temperature Measurement, Probe Number = 5, T = 20.046000 C 11:23:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.34 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:23:55 Integrated Voltage Measurement... 11:24:17 Voltage Offset Correction: v_off_ini = -0.000000702 V, v_off_fin = -0.000001031 V 11:24:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158421722 Vs 11:24:17 Integrated Voltage Measurement... 11:24:39 Voltage Offset Correction: v_off_ini = 0.000000717 V, v_off_fin = -0.000001697 V 11:24:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392443 Vs 11:24:53 Temperature Measurement, Probe Number = 0, T = 20.340000 C 11:24:54 Temperature Measurement, Probe Number = 1, T = 20.095000 C 11:24:54 Temperature Measurement, Probe Number = 2, T = 20.103000 C 11:24:55 Temperature Measurement, Probe Number = 3, T = 20.067000 C 11:24:55 Temperature Measurement, Probe Number = 4, T = 20.075000 C 11:24:56 Temperature Measurement, Probe Number = 5, T = 20.046000 C 11:24:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.34 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:24:56 Integrated Voltage Measurement... 11:25:18 Voltage Offset Correction: v_off_ini = -0.000002582 V, v_off_fin = -0.000003073 V 11:25:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158440429 Vs 11:25:18 Integrated Voltage Measurement... 11:25:40 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000003248 V 11:25:40 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158390945 Vs 11:25:54 Temperature Measurement, Probe Number = 0, T = 20.326000 C 11:25:54 Temperature Measurement, Probe Number = 1, T = 20.095000 C 11:25:55 Temperature Measurement, Probe Number = 2, T = 20.104000 C 11:25:56 Temperature Measurement, Probe Number = 3, T = 20.067000 C 11:25:56 Temperature Measurement, Probe Number = 4, T = 20.075000 C 11:25:57 Temperature Measurement, Probe Number = 5, T = 20.047000 C 11:25:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.33 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.05 11:25:57 Integrated Voltage Measurement... 11:26:19 Voltage Offset Correction: v_off_ini = -0.000001755 V, v_off_fin = -0.000001850 V 11:26:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424755 Vs 11:26:19 Integrated Voltage Measurement... 11:26:41 Voltage Offset Correction: v_off_ini = -0.000001302 V, v_off_fin = -0.000003943 V 11:26:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158368783 Vs 11:26:55 Temperature Measurement, Probe Number = 0, T = 20.321000 C 11:26:55 Temperature Measurement, Probe Number = 1, T = 20.094000 C 11:26:56 Temperature Measurement, Probe Number = 2, T = 20.105000 C 11:26:57 Temperature Measurement, Probe Number = 3, T = 20.070000 C 11:26:57 Temperature Measurement, Probe Number = 4, T = 20.076000 C 11:26:58 Temperature Measurement, Probe Number = 5, T = 20.047000 C 11:26:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 11:26:58 Integrated Voltage Measurement... 11:27:20 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = 0.000000293 V 11:27:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398712 Vs 11:27:20 Integrated Voltage Measurement... 11:27:43 Voltage Offset Correction: v_off_ini = -0.000001046 V, v_off_fin = -0.000002963 V 11:27:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386049 Vs 11:27:56 Temperature Measurement, Probe Number = 0, T = 20.307000 C 11:27:57 Temperature Measurement, Probe Number = 1, T = 20.097000 C 11:27:57 Temperature Measurement, Probe Number = 2, T = 20.106000 C 11:27:58 Temperature Measurement, Probe Number = 3, T = 20.068000 C 11:27:59 Temperature Measurement, Probe Number = 4, T = 20.077000 C 11:27:59 Temperature Measurement, Probe Number = 5, T = 20.048000 C 11:27:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 11:27:59 Integrated Voltage Measurement... 11:28:21 Voltage Offset Correction: v_off_ini = 0.000003291 V, v_off_fin = -0.000000965 V 11:28:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158367748 Vs 11:28:21 Integrated Voltage Measurement... 11:28:43 Voltage Offset Correction: v_off_ini = -0.000001895 V, v_off_fin = -0.000003745 V 11:28:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378489 Vs 12:24:57 Temperature Measurement, Probe Number = 0, T = 20.045000 C 12:24:58 Temperature Measurement, Probe Number = 1, T = 20.087000 C 12:24:58 Temperature Measurement, Probe Number = 2, T = 20.106000 C 12:24:59 Temperature Measurement, Probe Number = 3, T = 20.057000 C 12:25:00 Temperature Measurement, Probe Number = 4, T = 20.082000 C 12:25:00 Temperature Measurement, Probe Number = 5, T = 20.048000 C 12:25:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:25:00 Integrated Voltage Measurement... 12:25:22 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = -0.000001185 V 12:25:23 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158467255 Vs 12:25:23 Integrated Voltage Measurement... 12:25:45 Voltage Offset Correction: v_off_ini = -0.000002838 V, v_off_fin = -0.000001244 V 12:25:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412301 Vs 12:25:58 Temperature Measurement, Probe Number = 0, T = 20.072000 C 12:25:59 Temperature Measurement, Probe Number = 1, T = 20.079000 C 12:25:59 Temperature Measurement, Probe Number = 2, T = 20.101000 C 12:26:00 Temperature Measurement, Probe Number = 3, T = 20.054000 C 12:26:01 Temperature Measurement, Probe Number = 4, T = 20.080000 C 12:26:01 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:26:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:26:01 Integrated Voltage Measurement... 12:26:23 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000001207 V 12:26:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158438009 Vs 12:26:24 Integrated Voltage Measurement... 12:26:46 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000000936 V 12:26:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422214 Vs 12:27:00 Temperature Measurement, Probe Number = 0, T = 20.087000 C 12:27:00 Temperature Measurement, Probe Number = 1, T = 20.083000 C 12:27:01 Temperature Measurement, Probe Number = 2, T = 20.101000 C 12:27:02 Temperature Measurement, Probe Number = 3, T = 20.054000 C 12:27:02 Temperature Measurement, Probe Number = 4, T = 20.080000 C 12:27:03 Temperature Measurement, Probe Number = 5, T = 20.043000 C 12:27:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.04 12:27:03 Integrated Voltage Measurement... 12:27:25 Voltage Offset Correction: v_off_ini = -0.000002415 V, v_off_fin = 0.000000461 V 12:27:25 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158434240 Vs 12:27:25 Integrated Voltage Measurement... 12:27:47 Voltage Offset Correction: v_off_ini = -0.000002473 V, v_off_fin = -0.000004770 V 12:27:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378721 Vs 12:28:01 Temperature Measurement, Probe Number = 0, T = 20.106000 C 12:28:02 Temperature Measurement, Probe Number = 1, T = 20.087000 C 12:28:02 Temperature Measurement, Probe Number = 2, T = 20.104000 C 12:28:03 Temperature Measurement, Probe Number = 3, T = 20.056000 C 12:28:03 Temperature Measurement, Probe Number = 4, T = 20.083000 C 12:28:04 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:28:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:28:04 Integrated Voltage Measurement... 12:28:27 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = 0.000001244 V 12:28:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420682 Vs 12:28:27 Integrated Voltage Measurement... 12:28:49 Voltage Offset Correction: v_off_ini = -0.000002884 V, v_off_fin = -0.000004743 V 12:28:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380293 Vs 12:29:03 Temperature Measurement, Probe Number = 0, T = 20.114000 C 12:29:03 Temperature Measurement, Probe Number = 1, T = 20.088000 C 12:29:04 Temperature Measurement, Probe Number = 2, T = 20.107000 C 12:29:04 Temperature Measurement, Probe Number = 3, T = 20.055000 C 12:29:05 Temperature Measurement, Probe Number = 4, T = 20.084000 C 12:29:06 Temperature Measurement, Probe Number = 5, T = 20.047000 C 12:29:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:29:06 Integrated Voltage Measurement... 12:29:28 Voltage Offset Correction: v_off_ini = -0.000001603 V, v_off_fin = 0.000001113 V 12:29:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424772 Vs 12:29:28 Integrated Voltage Measurement... 12:29:50 Voltage Offset Correction: v_off_ini = -0.000002774 V, v_off_fin = -0.000002811 V 12:29:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158411524 Vs 12:30:04 Temperature Measurement, Probe Number = 0, T = 20.098000 C 12:30:04 Temperature Measurement, Probe Number = 1, T = 20.088000 C 12:30:05 Temperature Measurement, Probe Number = 2, T = 20.103000 C 12:30:06 Temperature Measurement, Probe Number = 3, T = 20.053000 C 12:30:06 Temperature Measurement, Probe Number = 4, T = 20.081000 C 12:30:07 Temperature Measurement, Probe Number = 5, T = 20.044000 C 12:30:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.04 12:30:07 Integrated Voltage Measurement... 12:30:29 Voltage Offset Correction: v_off_ini = -0.000002518 V, v_off_fin = 0.000000439 V 12:30:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158444347 Vs 12:30:29 Integrated Voltage Measurement... 12:30:58 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000001061 V 12:30:58 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158396698 Vs 12:31:12 Temperature Measurement, Probe Number = 0, T = 20.078000 C 12:31:12 Temperature Measurement, Probe Number = 1, T = 20.087000 C 12:31:13 Temperature Measurement, Probe Number = 2, T = 20.099000 C 12:31:13 Temperature Measurement, Probe Number = 3, T = 20.054000 C 12:31:14 Temperature Measurement, Probe Number = 4, T = 20.080000 C 12:31:15 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:31:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:31:15 Integrated Voltage Measurement... 12:31:37 Voltage Offset Correction: v_off_ini = -0.000001120 V, v_off_fin = -0.000000066 V 12:31:37 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158407722 Vs 12:31:37 Integrated Voltage Measurement... 12:32:00 Voltage Offset Correction: v_off_ini = 0.000000586 V, v_off_fin = -0.000002628 V 12:32:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424798 Vs 12:32:14 Temperature Measurement, Probe Number = 0, T = 20.102000 C 12:32:14 Temperature Measurement, Probe Number = 1, T = 20.084000 C 12:32:15 Temperature Measurement, Probe Number = 2, T = 20.103000 C 12:32:15 Temperature Measurement, Probe Number = 3, T = 20.058000 C 12:32:16 Temperature Measurement, Probe Number = 4, T = 20.082000 C 12:32:17 Temperature Measurement, Probe Number = 5, T = 20.045000 C 12:32:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.08 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:32:17 Integrated Voltage Measurement... 12:32:39 Voltage Offset Correction: v_off_ini = -0.000002840 V, v_off_fin = -0.000001186 V 12:32:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158462650 Vs 12:32:39 Integrated Voltage Measurement... 12:33:01 Voltage Offset Correction: v_off_ini = 0.000001698 V, v_off_fin = -0.000002650 V 12:33:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158452730 Vs 12:33:15 Temperature Measurement, Probe Number = 0, T = 20.120000 C 12:33:16 Temperature Measurement, Probe Number = 1, T = 20.090000 C 12:33:16 Temperature Measurement, Probe Number = 2, T = 20.105000 C 12:33:17 Temperature Measurement, Probe Number = 3, T = 20.059000 C 12:33:17 Temperature Measurement, Probe Number = 4, T = 20.084000 C 12:33:18 Temperature Measurement, Probe Number = 5, T = 20.047000 C 12:33:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 12:33:18 Integrated Voltage Measurement... 12:33:40 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000003213 V 12:33:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158476930 Vs 12:33:41 Integrated Voltage Measurement... 12:34:03 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000004311 V 12:34:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158409338 Vs 12:34:16 Temperature Measurement, Probe Number = 0, T = 20.125000 C 12:34:17 Temperature Measurement, Probe Number = 1, T = 20.090000 C 12:34:18 Temperature Measurement, Probe Number = 2, T = 20.111000 C 12:34:18 Temperature Measurement, Probe Number = 3, T = 20.058000 C 12:34:19 Temperature Measurement, Probe Number = 4, T = 20.086000 C 12:34:19 Temperature Measurement, Probe Number = 5, T = 20.048000 C 12:34:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 12:34:19 Integrated Voltage Measurement... 12:34:42 Voltage Offset Correction: v_off_ini = -0.000000937 V, v_off_fin = -0.000000768 V 12:34:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411077 Vs 12:34:42 Integrated Voltage Measurement... 12:35:04 Voltage Offset Correction: v_off_ini = -0.000001859 V, v_off_fin = -0.000002657 V 12:35:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419821 Vs 13:31:18 Temperature Measurement, Probe Number = 0, T = 20.114000 C 13:31:18 Temperature Measurement, Probe Number = 1, T = 20.093000 C 13:31:19 Temperature Measurement, Probe Number = 2, T = 20.116000 C 13:31:19 Temperature Measurement, Probe Number = 3, T = 20.060000 C 13:31:20 Temperature Measurement, Probe Number = 4, T = 20.093000 C 13:31:21 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:31:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 13:31:21 Integrated Voltage Measurement... 13:31:43 Voltage Offset Correction: v_off_ini = -0.000002364 V, v_off_fin = -0.000001822 V 13:31:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158487948 Vs 13:31:43 Integrated Voltage Measurement... 13:32:06 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000001449 V 13:32:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158429643 Vs 13:32:19 Temperature Measurement, Probe Number = 0, T = 20.100000 C 13:32:20 Temperature Measurement, Probe Number = 1, T = 20.093000 C 13:32:20 Temperature Measurement, Probe Number = 2, T = 20.121000 C 13:32:21 Temperature Measurement, Probe Number = 3, T = 20.061000 C 13:32:22 Temperature Measurement, Probe Number = 4, T = 20.094000 C 13:32:22 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:32:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 13:32:22 Integrated Voltage Measurement... 13:32:44 Voltage Offset Correction: v_off_ini = -0.000002224 V, v_off_fin = -0.000000790 V 13:32:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437683 Vs 13:32:44 Integrated Voltage Measurement... 13:33:06 Voltage Offset Correction: v_off_ini = 0.000000483 V, v_off_fin = -0.000002378 V 13:33:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436427 Vs 13:33:20 Temperature Measurement, Probe Number = 0, T = 20.118000 C 13:33:21 Temperature Measurement, Probe Number = 1, T = 20.095000 C 13:33:21 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:33:22 Temperature Measurement, Probe Number = 3, T = 20.062000 C 13:33:22 Temperature Measurement, Probe Number = 4, T = 20.096000 C 13:33:23 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:33:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:33:23 Integrated Voltage Measurement... 13:33:45 Voltage Offset Correction: v_off_ini = -0.000002605 V, v_off_fin = -0.000001463 V 13:33:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456609 Vs 13:33:45 Integrated Voltage Measurement... 13:34:07 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000002195 V 13:34:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421097 Vs 13:34:21 Temperature Measurement, Probe Number = 0, T = 20.148000 C 13:34:22 Temperature Measurement, Probe Number = 1, T = 20.094000 C 13:34:22 Temperature Measurement, Probe Number = 2, T = 20.121000 C 13:34:23 Temperature Measurement, Probe Number = 3, T = 20.060000 C 13:34:24 Temperature Measurement, Probe Number = 4, T = 20.095000 C 13:34:24 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:34:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 13:34:24 Integrated Voltage Measurement... 13:34:47 Voltage Offset Correction: v_off_ini = -0.000001566 V, v_off_fin = 0.000004909 V 13:34:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403538 Vs 13:34:47 Integrated Voltage Measurement... 13:35:09 Voltage Offset Correction: v_off_ini = -0.000002839 V, v_off_fin = -0.000002371 V 13:35:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418191 Vs 13:35:23 Temperature Measurement, Probe Number = 0, T = 20.146000 C 13:35:23 Temperature Measurement, Probe Number = 1, T = 20.097000 C 13:35:24 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:35:25 Temperature Measurement, Probe Number = 3, T = 20.060000 C 13:35:25 Temperature Measurement, Probe Number = 4, T = 20.095000 C 13:35:26 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:35:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 13:35:26 Integrated Voltage Measurement... 13:35:48 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000001866 V 13:35:48 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158451777 Vs 13:35:48 Integrated Voltage Measurement... 13:36:10 Voltage Offset Correction: v_off_ini = -0.000001573 V, v_off_fin = -0.000002480 V 13:36:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418281 Vs 13:36:24 Temperature Measurement, Probe Number = 0, T = 20.140000 C 13:36:25 Temperature Measurement, Probe Number = 1, T = 20.099000 C 13:36:25 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:36:26 Temperature Measurement, Probe Number = 3, T = 20.062000 C 13:36:26 Temperature Measurement, Probe Number = 4, T = 20.096000 C 13:36:27 Temperature Measurement, Probe Number = 5, T = 20.054000 C 13:36:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:36:27 Integrated Voltage Measurement... 13:36:49 Voltage Offset Correction: v_off_ini = 0.000000929 V, v_off_fin = 0.000002327 V 13:36:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417010 Vs 13:36:49 Integrated Voltage Measurement... 13:37:11 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = -0.000001478 V 13:37:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435149 Vs 13:37:25 Temperature Measurement, Probe Number = 0, T = 20.163000 C 13:37:26 Temperature Measurement, Probe Number = 1, T = 20.097000 C 13:37:26 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:37:27 Temperature Measurement, Probe Number = 3, T = 20.062000 C 13:37:27 Temperature Measurement, Probe Number = 4, T = 20.096000 C 13:37:28 Temperature Measurement, Probe Number = 5, T = 20.054000 C 13:37:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:37:28 Integrated Voltage Measurement... 13:37:50 Voltage Offset Correction: v_off_ini = -0.000001998 V, v_off_fin = -0.000000790 V 13:37:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158434138 Vs 13:37:50 Integrated Voltage Measurement... 13:38:13 Voltage Offset Correction: v_off_ini = 0.000001097 V, v_off_fin = -0.000002882 V 13:38:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158454228 Vs 13:38:26 Temperature Measurement, Probe Number = 0, T = 20.181000 C 13:38:27 Temperature Measurement, Probe Number = 1, T = 20.097000 C 13:38:27 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:38:28 Temperature Measurement, Probe Number = 3, T = 20.063000 C 13:38:29 Temperature Measurement, Probe Number = 4, T = 20.097000 C 13:38:29 Temperature Measurement, Probe Number = 5, T = 20.053000 C 13:38:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:38:29 Integrated Voltage Measurement... 13:38:51 Voltage Offset Correction: v_off_ini = -0.000001537 V, v_off_fin = -0.000000980 V 13:38:51 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158449266 Vs 13:38:51 Integrated Voltage Measurement... 13:39:14 Voltage Offset Correction: v_off_ini = 0.000001697 V, v_off_fin = -0.000001112 V 13:39:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158456591 Vs 13:39:27 Temperature Measurement, Probe Number = 0, T = 20.193000 C 13:39:28 Temperature Measurement, Probe Number = 1, T = 20.096000 C 13:39:28 Temperature Measurement, Probe Number = 2, T = 20.123000 C 13:39:29 Temperature Measurement, Probe Number = 3, T = 20.063000 C 13:39:30 Temperature Measurement, Probe Number = 4, T = 20.096000 C 13:39:30 Temperature Measurement, Probe Number = 5, T = 20.054000 C 13:39:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:39:30 Integrated Voltage Measurement... 13:39:52 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001917 V 13:39:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158444803 Vs 13:39:53 Integrated Voltage Measurement... 13:40:15 Voltage Offset Correction: v_off_ini = -0.000000966 V, v_off_fin = -0.000000878 V 13:40:15 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158431537 Vs 13:40:29 Temperature Measurement, Probe Number = 0, T = 20.171000 C 13:40:29 Temperature Measurement, Probe Number = 1, T = 20.098000 C 13:40:30 Temperature Measurement, Probe Number = 2, T = 20.122000 C 13:40:30 Temperature Measurement, Probe Number = 3, T = 20.064000 C 13:40:31 Temperature Measurement, Probe Number = 4, T = 20.097000 C 13:40:32 Temperature Measurement, Probe Number = 5, T = 20.054000 C 13:40:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 13:40:32 Integrated Voltage Measurement... 13:40:54 Voltage Offset Correction: v_off_ini = -0.000003066 V, v_off_fin = -0.000001610 V 13:40:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459663 Vs 13:40:54 Integrated Voltage Measurement... 13:41:16 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000003922 V 13:41:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403285 Vs 14:37:30 Temperature Measurement, Probe Number = 0, T = 20.121000 C 14:37:30 Temperature Measurement, Probe Number = 1, T = 20.097000 C 14:37:31 Temperature Measurement, Probe Number = 2, T = 20.127000 C 14:37:32 Temperature Measurement, Probe Number = 3, T = 20.057000 C 14:37:32 Temperature Measurement, Probe Number = 4, T = 20.101000 C 14:37:33 Temperature Measurement, Probe Number = 5, T = 20.055000 C 14:37:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:37:33 Integrated Voltage Measurement... 14:37:55 Voltage Offset Correction: v_off_ini = -0.000001104 V, v_off_fin = -0.000000995 V 14:37:55 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158478671 Vs 14:37:55 Integrated Voltage Measurement... 14:38:17 Voltage Offset Correction: v_off_ini = -0.000001228 V, v_off_fin = -0.000000834 V 14:38:17 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158438310 Vs 14:38:31 Temperature Measurement, Probe Number = 0, T = 20.164000 C 14:38:31 Temperature Measurement, Probe Number = 1, T = 20.093000 C 14:38:32 Temperature Measurement, Probe Number = 2, T = 20.125000 C 14:38:32 Temperature Measurement, Probe Number = 3, T = 20.059000 C 14:38:33 Temperature Measurement, Probe Number = 4, T = 20.100000 C 14:38:34 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:38:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:38:34 Integrated Voltage Measurement... 14:38:56 Voltage Offset Correction: v_off_ini = -0.000001931 V, v_off_fin = -0.000003233 V 14:38:57 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158473551 Vs 14:38:57 Integrated Voltage Measurement... 14:39:19 Voltage Offset Correction: v_off_ini = 0.000000219 V, v_off_fin = -0.000004161 V 14:39:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418611 Vs 14:39:33 Temperature Measurement, Probe Number = 0, T = 20.172000 C 14:39:33 Temperature Measurement, Probe Number = 1, T = 20.093000 C 14:39:34 Temperature Measurement, Probe Number = 2, T = 20.124000 C 14:39:35 Temperature Measurement, Probe Number = 3, T = 20.059000 C 14:39:35 Temperature Measurement, Probe Number = 4, T = 20.100000 C 14:39:36 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:39:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:39:36 Integrated Voltage Measurement... 14:39:58 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000001353 V 14:39:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455298 Vs 14:39:58 Integrated Voltage Measurement... 14:40:20 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000003218 V 14:40:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420170 Vs 14:40:34 Temperature Measurement, Probe Number = 0, T = 20.172000 C 14:40:35 Temperature Measurement, Probe Number = 1, T = 20.095000 C 14:40:35 Temperature Measurement, Probe Number = 2, T = 20.125000 C 14:40:36 Temperature Measurement, Probe Number = 3, T = 20.061000 C 14:40:36 Temperature Measurement, Probe Number = 4, T = 20.101000 C 14:40:37 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:40:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:40:37 Integrated Voltage Measurement... 14:40:59 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000001273 V 14:41:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441423 Vs 14:41:00 Integrated Voltage Measurement... 14:41:22 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000002486 V 14:41:22 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158422975 Vs 14:41:35 Temperature Measurement, Probe Number = 0, T = 20.200000 C 14:41:36 Temperature Measurement, Probe Number = 1, T = 20.096000 C 14:41:37 Temperature Measurement, Probe Number = 2, T = 20.127000 C 14:41:37 Temperature Measurement, Probe Number = 3, T = 20.065000 C 14:41:38 Temperature Measurement, Probe Number = 4, T = 20.101000 C 14:41:38 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:41:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:41:38 Integrated Voltage Measurement... 14:42:01 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000000512 V 14:42:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158443987 Vs 14:42:01 Integrated Voltage Measurement... 14:42:23 Voltage Offset Correction: v_off_ini = 0.000000878 V, v_off_fin = -0.000003204 V 14:42:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158456804 Vs 14:42:37 Temperature Measurement, Probe Number = 0, T = 20.196000 C 14:42:38 Temperature Measurement, Probe Number = 1, T = 20.097000 C 14:42:38 Temperature Measurement, Probe Number = 2, T = 20.125000 C 14:42:39 Temperature Measurement, Probe Number = 3, T = 20.064000 C 14:42:40 Temperature Measurement, Probe Number = 4, T = 20.101000 C 14:42:40 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:42:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:42:40 Integrated Voltage Measurement... 14:43:02 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = -0.000003746 V 14:43:02 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158482581 Vs 14:43:02 Integrated Voltage Measurement... 14:43:25 Voltage Offset Correction: v_off_ini = 0.000001712 V, v_off_fin = -0.000004097 V 14:43:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430431 Vs 14:43:39 Temperature Measurement, Probe Number = 0, T = 20.204000 C 14:43:39 Temperature Measurement, Probe Number = 1, T = 20.098000 C 14:43:40 Temperature Measurement, Probe Number = 2, T = 20.126000 C 14:43:40 Temperature Measurement, Probe Number = 3, T = 20.065000 C 14:43:41 Temperature Measurement, Probe Number = 4, T = 20.101000 C 14:43:42 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:43:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:43:42 Integrated Voltage Measurement... 14:44:04 Voltage Offset Correction: v_off_ini = -0.000002422 V, v_off_fin = -0.000000732 V 14:44:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459535 Vs 14:44:04 Integrated Voltage Measurement... 14:44:26 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000000300 V 14:44:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444826 Vs 14:44:40 Temperature Measurement, Probe Number = 0, T = 20.209000 C 14:44:41 Temperature Measurement, Probe Number = 1, T = 20.096000 C 14:44:41 Temperature Measurement, Probe Number = 2, T = 20.125000 C 14:44:42 Temperature Measurement, Probe Number = 3, T = 20.064000 C 14:44:42 Temperature Measurement, Probe Number = 4, T = 20.099000 C 14:44:43 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:44:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:44:43 Integrated Voltage Measurement... 14:45:05 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000002970 V 14:45:05 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158474559 Vs 14:45:05 Integrated Voltage Measurement... 14:45:28 Voltage Offset Correction: v_off_ini = -0.000003571 V, v_off_fin = -0.000003805 V 14:45:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403657 Vs 14:45:41 Temperature Measurement, Probe Number = 0, T = 20.187000 C 14:45:42 Temperature Measurement, Probe Number = 1, T = 20.097000 C 14:45:42 Temperature Measurement, Probe Number = 2, T = 20.128000 C 14:45:43 Temperature Measurement, Probe Number = 3, T = 20.064000 C 14:45:44 Temperature Measurement, Probe Number = 4, T = 20.100000 C 14:45:44 Temperature Measurement, Probe Number = 5, T = 20.054000 C 14:45:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:45:44 Integrated Voltage Measurement... 14:46:06 Voltage Offset Correction: v_off_ini = -0.000002869 V, v_off_fin = -0.000001178 V 14:46:06 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158458615 Vs 14:46:06 Integrated Voltage Measurement... 14:46:29 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = -0.000001844 V 14:46:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434753 Vs 14:46:42 Temperature Measurement, Probe Number = 0, T = 20.166000 C 14:46:43 Temperature Measurement, Probe Number = 1, T = 20.096000 C 14:46:43 Temperature Measurement, Probe Number = 2, T = 20.126000 C 14:46:44 Temperature Measurement, Probe Number = 3, T = 20.062000 C 14:46:45 Temperature Measurement, Probe Number = 4, T = 20.100000 C 14:46:45 Temperature Measurement, Probe Number = 5, T = 20.053000 C 14:46:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.06 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 14:46:45 Integrated Voltage Measurement... 14:47:07 Voltage Offset Correction: v_off_ini = -0.000004660 V, v_off_fin = -0.000001602 V 14:47:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158465868 Vs 14:47:07 Integrated Voltage Measurement... 14:47:30 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = -0.000003337 V 14:47:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439302 Vs 15:43:43 Temperature Measurement, Probe Number = 0, T = 20.171000 C 15:43:44 Temperature Measurement, Probe Number = 1, T = 20.095000 C 15:43:44 Temperature Measurement, Probe Number = 2, T = 20.127000 C 15:43:45 Temperature Measurement, Probe Number = 3, T = 20.065000 C 15:43:46 Temperature Measurement, Probe Number = 4, T = 20.103000 C 15:43:46 Temperature Measurement, Probe Number = 5, T = 20.054000 C 15:43:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 15:43:46 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = -0.000000176 V 15:44:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158487056 Vs 15:44:08 Integrated Voltage Measurement... 15:44:30 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002392 V 15:44:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158454144 Vs 15:44:44 Temperature Measurement, Probe Number = 0, T = 20.203000 C 15:44:45 Temperature Measurement, Probe Number = 1, T = 20.099000 C 15:44:45 Temperature Measurement, Probe Number = 2, T = 20.130000 C 15:44:46 Temperature Measurement, Probe Number = 3, T = 20.070000 C 15:44:46 Temperature Measurement, Probe Number = 4, T = 20.105000 C 15:44:47 Temperature Measurement, Probe Number = 5, T = 20.057000 C 15:44:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:44:47 Integrated Voltage Measurement... 15:45:09 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = 0.000000498 V 15:45:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158463518 Vs 15:45:09 Integrated Voltage Measurement... 15:45:31 Voltage Offset Correction: v_off_ini = 0.000000110 V, v_off_fin = -0.000003870 V 15:45:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443692 Vs 15:45:45 Temperature Measurement, Probe Number = 0, T = 20.248000 C 15:45:46 Temperature Measurement, Probe Number = 1, T = 20.102000 C 15:45:46 Temperature Measurement, Probe Number = 2, T = 20.133000 C 15:45:47 Temperature Measurement, Probe Number = 3, T = 20.076000 C 15:45:48 Temperature Measurement, Probe Number = 4, T = 20.108000 C 15:45:48 Temperature Measurement, Probe Number = 5, T = 20.059000 C 15:45:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:45:48 Integrated Voltage Measurement... 15:46:10 Voltage Offset Correction: v_off_ini = -0.000000776 V, v_off_fin = -0.000000293 V 15:46:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158444630 Vs 15:46:10 Integrated Voltage Measurement... 15:46:33 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000002488 V 15:46:33 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158429907 Vs 15:46:46 Temperature Measurement, Probe Number = 0, T = 20.284000 C 15:46:47 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:46:47 Temperature Measurement, Probe Number = 2, T = 20.135000 C 15:46:48 Temperature Measurement, Probe Number = 3, T = 20.079000 C 15:46:49 Temperature Measurement, Probe Number = 4, T = 20.109000 C 15:46:49 Temperature Measurement, Probe Number = 5, T = 20.059000 C 15:46:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:46:49 Integrated Voltage Measurement... 15:47:11 Voltage Offset Correction: v_off_ini = -0.000002277 V, v_off_fin = -0.000000410 V 15:47:12 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158472987 Vs 15:47:12 Integrated Voltage Measurement... 15:47:34 Voltage Offset Correction: v_off_ini = -0.000002736 V, v_off_fin = -0.000003892 V 15:47:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426145 Vs 15:47:48 Temperature Measurement, Probe Number = 0, T = 20.322000 C 15:47:48 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:47:49 Temperature Measurement, Probe Number = 2, T = 20.135000 C 15:47:50 Temperature Measurement, Probe Number = 3, T = 20.080000 C 15:47:50 Temperature Measurement, Probe Number = 4, T = 20.109000 C 15:47:51 Temperature Measurement, Probe Number = 5, T = 20.059000 C 15:47:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:47:51 Integrated Voltage Measurement... 15:48:13 Voltage Offset Correction: v_off_ini = -0.000001274 V, v_off_fin = -0.000000798 V 15:48:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456601 Vs 15:48:13 Integrated Voltage Measurement... 15:48:36 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000001434 V 15:48:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441355 Vs 15:48:49 Temperature Measurement, Probe Number = 0, T = 20.325000 C 15:48:50 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:48:50 Temperature Measurement, Probe Number = 2, T = 20.134000 C 15:48:51 Temperature Measurement, Probe Number = 3, T = 20.079000 C 15:48:52 Temperature Measurement, Probe Number = 4, T = 20.108000 C 15:48:52 Temperature Measurement, Probe Number = 5, T = 20.058000 C 15:48:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:48:52 Integrated Voltage Measurement... 15:49:14 Voltage Offset Correction: v_off_ini = -0.000002372 V, v_off_fin = -0.000000783 V 15:49:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158464612 Vs 15:49:15 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000001464 V 15:49:37 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158450225 Vs 15:49:51 Temperature Measurement, Probe Number = 0, T = 20.321000 C 15:49:51 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:49:52 Temperature Measurement, Probe Number = 2, T = 20.135000 C 15:49:52 Temperature Measurement, Probe Number = 3, T = 20.078000 C 15:49:53 Temperature Measurement, Probe Number = 4, T = 20.108000 C 15:49:54 Temperature Measurement, Probe Number = 5, T = 20.058000 C 15:49:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:49:54 Integrated Voltage Measurement... 15:50:16 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000000132 V 15:50:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158456061 Vs 15:50:17 Integrated Voltage Measurement... 15:50:39 Voltage Offset Correction: v_off_ini = -0.000001881 V, v_off_fin = -0.000001756 V 15:50:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449530 Vs 15:50:53 Temperature Measurement, Probe Number = 0, T = 20.303000 C 15:50:53 Temperature Measurement, Probe Number = 1, T = 20.100000 C 15:50:54 Temperature Measurement, Probe Number = 2, T = 20.133000 C 15:50:55 Temperature Measurement, Probe Number = 3, T = 20.078000 C 15:50:55 Temperature Measurement, Probe Number = 4, T = 20.107000 C 15:50:56 Temperature Measurement, Probe Number = 5, T = 20.056000 C 15:50:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:50:56 Integrated Voltage Measurement... 15:51:18 Voltage Offset Correction: v_off_ini = 0.000000666 V, v_off_fin = -0.000000607 V 15:51:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431390 Vs 15:51:19 Integrated Voltage Measurement... 15:51:41 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000002012 V 15:51:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419650 Vs 15:51:55 Temperature Measurement, Probe Number = 0, T = 20.296000 C 15:51:55 Temperature Measurement, Probe Number = 1, T = 20.102000 C 15:51:56 Temperature Measurement, Probe Number = 2, T = 20.132000 C 15:51:57 Temperature Measurement, Probe Number = 3, T = 20.078000 C 15:51:57 Temperature Measurement, Probe Number = 4, T = 20.106000 C 15:51:58 Temperature Measurement, Probe Number = 5, T = 20.057000 C 15:51:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:51:58 Integrated Voltage Measurement... 15:52:20 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = 0.000000249 V 15:52:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446494 Vs 15:52:20 Integrated Voltage Measurement... 15:52:43 Voltage Offset Correction: v_off_ini = -0.000000893 V, v_off_fin = -0.000004580 V 15:52:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158410944 Vs 15:52:56 Temperature Measurement, Probe Number = 0, T = 20.280000 C 15:52:57 Temperature Measurement, Probe Number = 1, T = 20.101000 C 15:52:57 Temperature Measurement, Probe Number = 2, T = 20.134000 C 15:52:58 Temperature Measurement, Probe Number = 3, T = 20.077000 C 15:52:59 Temperature Measurement, Probe Number = 4, T = 20.107000 C 15:52:59 Temperature Measurement, Probe Number = 5, T = 20.058000 C 15:52:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 15:52:59 Integrated Voltage Measurement... 15:53:21 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001756 V 15:53:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158483607 Vs 15:53:21 Integrated Voltage Measurement... 15:53:44 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000002407 V 15:53:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422793 Vs 16:49:58 Temperature Measurement, Probe Number = 0, T = 20.163000 C 16:49:58 Temperature Measurement, Probe Number = 1, T = 20.100000 C 16:49:59 Temperature Measurement, Probe Number = 2, T = 20.135000 C 16:50:00 Temperature Measurement, Probe Number = 3, T = 20.081000 C 16:50:00 Temperature Measurement, Probe Number = 4, T = 20.109000 C 16:50:01 Temperature Measurement, Probe Number = 5, T = 20.060000 C 16:50:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:50:01 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = -0.000000776 V, v_off_fin = 0.000000864 V 16:50:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158489189 Vs 16:50:23 Integrated Voltage Measurement... 16:50:46 Voltage Offset Correction: v_off_ini = -0.000000542 V, v_off_fin = -0.000001288 V 16:50:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430935 Vs 16:50:59 Temperature Measurement, Probe Number = 0, T = 20.176000 C 16:51:00 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:51:00 Temperature Measurement, Probe Number = 2, T = 20.136000 C 16:51:01 Temperature Measurement, Probe Number = 3, T = 20.082000 C 16:51:02 Temperature Measurement, Probe Number = 4, T = 20.110000 C 16:51:02 Temperature Measurement, Probe Number = 5, T = 20.060000 C 16:51:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:51:02 Integrated Voltage Measurement... 16:51:24 Voltage Offset Correction: v_off_ini = 0.000000066 V, v_off_fin = 0.000000073 V 16:51:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158429601 Vs 16:51:25 Integrated Voltage Measurement... 16:51:47 Voltage Offset Correction: v_off_ini = -0.000001113 V, v_off_fin = -0.000001962 V 16:51:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418751 Vs 16:52:01 Temperature Measurement, Probe Number = 0, T = 20.189000 C 16:52:01 Temperature Measurement, Probe Number = 1, T = 20.104000 C 16:52:02 Temperature Measurement, Probe Number = 2, T = 20.137000 C 16:52:03 Temperature Measurement, Probe Number = 3, T = 20.083000 C 16:52:03 Temperature Measurement, Probe Number = 4, T = 20.112000 C 16:52:04 Temperature Measurement, Probe Number = 5, T = 20.059000 C 16:52:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:52:04 Integrated Voltage Measurement... 16:52:26 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = 0.000002064 V 16:52:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158445502 Vs 16:52:26 Integrated Voltage Measurement... 16:52:48 Voltage Offset Correction: v_off_ini = 0.000002979 V, v_off_fin = -0.000002094 V 16:52:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158472476 Vs 16:53:02 Temperature Measurement, Probe Number = 0, T = 20.177000 C 16:53:02 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:53:03 Temperature Measurement, Probe Number = 2, T = 20.139000 C 16:53:04 Temperature Measurement, Probe Number = 3, T = 20.080000 C 16:53:04 Temperature Measurement, Probe Number = 4, T = 20.112000 C 16:53:05 Temperature Measurement, Probe Number = 5, T = 20.060000 C 16:53:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:53:05 Integrated Voltage Measurement... 16:53:27 Voltage Offset Correction: v_off_ini = -0.000001589 V, v_off_fin = -0.000000944 V 16:53:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158445577 Vs 16:53:27 Integrated Voltage Measurement... 16:53:49 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = -0.000001361 V 16:53:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438321 Vs 16:54:03 Temperature Measurement, Probe Number = 0, T = 20.182000 C 16:54:04 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:54:04 Temperature Measurement, Probe Number = 2, T = 20.137000 C 16:54:05 Temperature Measurement, Probe Number = 3, T = 20.080000 C 16:54:05 Temperature Measurement, Probe Number = 4, T = 20.113000 C 16:54:06 Temperature Measurement, Probe Number = 5, T = 20.061000 C 16:54:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:54:06 Integrated Voltage Measurement... 16:54:28 Voltage Offset Correction: v_off_ini = -0.000002438 V, v_off_fin = -0.000002767 V 16:54:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455306 Vs 16:54:28 Integrated Voltage Measurement... 16:54:51 Voltage Offset Correction: v_off_ini = 0.000001025 V, v_off_fin = -0.000002577 V 16:54:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437271 Vs 16:55:04 Temperature Measurement, Probe Number = 0, T = 20.205000 C 16:55:05 Temperature Measurement, Probe Number = 1, T = 20.106000 C 16:55:06 Temperature Measurement, Probe Number = 2, T = 20.140000 C 16:55:06 Temperature Measurement, Probe Number = 3, T = 20.082000 C 16:55:07 Temperature Measurement, Probe Number = 4, T = 20.114000 C 16:55:07 Temperature Measurement, Probe Number = 5, T = 20.062000 C 16:55:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:55:07 Integrated Voltage Measurement... 16:55:30 Voltage Offset Correction: v_off_ini = -0.000002811 V, v_off_fin = -0.000001735 V 16:55:30 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158476984 Vs 16:55:30 Integrated Voltage Measurement... 16:55:52 Voltage Offset Correction: v_off_ini = -0.000000630 V, v_off_fin = -0.000002423 V 16:55:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424376 Vs 16:56:06 Temperature Measurement, Probe Number = 0, T = 20.201000 C 16:56:07 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:56:07 Temperature Measurement, Probe Number = 2, T = 20.141000 C 16:56:08 Temperature Measurement, Probe Number = 3, T = 20.084000 C 16:56:08 Temperature Measurement, Probe Number = 4, T = 20.113000 C 16:56:09 Temperature Measurement, Probe Number = 5, T = 20.062000 C 16:56:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:56:09 Integrated Voltage Measurement... 16:56:31 Voltage Offset Correction: v_off_ini = -0.000000629 V, v_off_fin = -0.000000176 V 16:56:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158448489 Vs 16:56:31 Integrated Voltage Measurement... 16:56:53 Voltage Offset Correction: v_off_ini = -0.000000834 V, v_off_fin = -0.000002642 V 16:56:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430134 Vs 16:57:07 Temperature Measurement, Probe Number = 0, T = 20.225000 C 16:57:08 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:57:08 Temperature Measurement, Probe Number = 2, T = 20.137000 C 16:57:09 Temperature Measurement, Probe Number = 3, T = 20.084000 C 16:57:09 Temperature Measurement, Probe Number = 4, T = 20.114000 C 16:57:10 Temperature Measurement, Probe Number = 5, T = 20.062000 C 16:57:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:57:10 Integrated Voltage Measurement... 16:57:32 Voltage Offset Correction: v_off_ini = -0.000002255 V, v_off_fin = -0.000000798 V 16:57:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158430040 Vs 16:57:32 Integrated Voltage Measurement... 16:57:55 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000001471 V 16:57:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425461 Vs 16:58:08 Temperature Measurement, Probe Number = 0, T = 20.197000 C 16:58:09 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:58:09 Temperature Measurement, Probe Number = 2, T = 20.138000 C 16:58:10 Temperature Measurement, Probe Number = 3, T = 20.083000 C 16:58:11 Temperature Measurement, Probe Number = 4, T = 20.114000 C 16:58:11 Temperature Measurement, Probe Number = 5, T = 20.062000 C 16:58:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:58:11 Integrated Voltage Measurement... 16:58:33 Voltage Offset Correction: v_off_ini = -0.000000857 V, v_off_fin = -0.000000783 V 16:58:33 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158439367 Vs 16:58:33 Integrated Voltage Measurement... 16:58:56 Voltage Offset Correction: v_off_ini = -0.000000981 V, v_off_fin = -0.000001377 V 16:58:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419601 Vs 16:59:09 Temperature Measurement, Probe Number = 0, T = 20.173000 C 16:59:10 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:59:11 Temperature Measurement, Probe Number = 2, T = 20.141000 C 16:59:11 Temperature Measurement, Probe Number = 3, T = 20.085000 C 16:59:12 Temperature Measurement, Probe Number = 4, T = 20.114000 C 16:59:12 Temperature Measurement, Probe Number = 5, T = 20.063000 C 16:59:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 16:59:12 Integrated Voltage Measurement... 16:59:35 Voltage Offset Correction: v_off_ini = -0.000002167 V, v_off_fin = -0.000002489 V 16:59:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158450896 Vs 16:59:35 Integrated Voltage Measurement... 16:59:57 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000002036 V 16:59:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158416355 Vs 17:56:10 Temperature Measurement, Probe Number = 0, T = 20.130000 C 17:56:11 Temperature Measurement, Probe Number = 1, T = 20.101000 C 17:56:12 Temperature Measurement, Probe Number = 2, T = 20.137000 C 17:56:12 Temperature Measurement, Probe Number = 3, T = 20.083000 C 17:56:13 Temperature Measurement, Probe Number = 4, T = 20.113000 C 17:56:13 Temperature Measurement, Probe Number = 5, T = 20.061000 C 17:56:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 17:56:13 Integrated Voltage Measurement... 17:56:36 Voltage Offset Correction: v_off_ini = -0.000000534 V, v_off_fin = -0.000000761 V 17:56:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158482200 Vs 17:56:36 Integrated Voltage Measurement... 17:56:58 Voltage Offset Correction: v_off_ini = -0.000000791 V, v_off_fin = -0.000001552 V 17:56:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430373 Vs 17:57:12 Temperature Measurement, Probe Number = 0, T = 20.112000 C 17:57:12 Temperature Measurement, Probe Number = 1, T = 20.098000 C 17:57:13 Temperature Measurement, Probe Number = 2, T = 20.131000 C 17:57:14 Temperature Measurement, Probe Number = 3, T = 20.082000 C 17:57:14 Temperature Measurement, Probe Number = 4, T = 20.110000 C 17:57:15 Temperature Measurement, Probe Number = 5, T = 20.059000 C 17:57:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 17:57:15 Integrated Voltage Measurement... 17:57:37 Voltage Offset Correction: v_off_ini = -0.000001676 V, v_off_fin = 0.000001859 V 17:57:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158436438 Vs 17:57:37 Integrated Voltage Measurement... 17:58:00 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000002526 V 17:58:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430030 Vs 17:58:13 Temperature Measurement, Probe Number = 0, T = 20.115000 C 17:58:14 Temperature Measurement, Probe Number = 1, T = 20.102000 C 17:58:14 Temperature Measurement, Probe Number = 2, T = 20.138000 C 17:58:15 Temperature Measurement, Probe Number = 3, T = 20.083000 C 17:58:16 Temperature Measurement, Probe Number = 4, T = 20.112000 C 17:58:16 Temperature Measurement, Probe Number = 5, T = 20.062000 C 17:58:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 17:58:16 Integrated Voltage Measurement... 17:58:38 Voltage Offset Correction: v_off_ini = -0.000002079 V, v_off_fin = 0.000002489 V 17:58:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420216 Vs 17:58:38 Integrated Voltage Measurement... 17:59:01 Voltage Offset Correction: v_off_ini = -0.000000469 V, v_off_fin = -0.000005675 V 17:59:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421507 Vs 17:59:14 Temperature Measurement, Probe Number = 0, T = 20.164000 C 17:59:15 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:59:15 Temperature Measurement, Probe Number = 2, T = 20.140000 C 17:59:16 Temperature Measurement, Probe Number = 3, T = 20.083000 C 17:59:17 Temperature Measurement, Probe Number = 4, T = 20.114000 C 17:59:17 Temperature Measurement, Probe Number = 5, T = 20.062000 C 17:59:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 17:59:17 Integrated Voltage Measurement... 17:59:40 Voltage Offset Correction: v_off_ini = -0.000001560 V, v_off_fin = -0.000005367 V 17:59:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158477590 Vs 17:59:40 Integrated Voltage Measurement... 18:00:02 Voltage Offset Correction: v_off_ini = -0.000001940 V, v_off_fin = -0.000002255 V 18:00:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158416035 Vs 18:00:15 Temperature Measurement, Probe Number = 0, T = 20.181000 C 18:00:16 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:00:17 Temperature Measurement, Probe Number = 2, T = 20.142000 C 18:00:17 Temperature Measurement, Probe Number = 3, T = 20.084000 C 18:00:18 Temperature Measurement, Probe Number = 4, T = 20.115000 C 18:00:18 Temperature Measurement, Probe Number = 5, T = 20.063000 C 18:00:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 18:00:18 Integrated Voltage Measurement... 18:00:41 Voltage Offset Correction: v_off_ini = -0.000001135 V, v_off_fin = -0.000001465 V 18:00:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158432161 Vs 18:00:41 Integrated Voltage Measurement... 18:01:04 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = -0.000001757 V 18:01:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426706 Vs 18:01:18 Temperature Measurement, Probe Number = 0, T = 20.189000 C 18:01:19 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:01:19 Temperature Measurement, Probe Number = 2, T = 20.144000 C 18:01:20 Temperature Measurement, Probe Number = 3, T = 20.084000 C 18:01:20 Temperature Measurement, Probe Number = 4, T = 20.116000 C 18:01:21 Temperature Measurement, Probe Number = 5, T = 20.063000 C 18:01:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.06 18:01:21 Integrated Voltage Measurement... 18:01:43 Voltage Offset Correction: v_off_ini = 0.000003039 V, v_off_fin = -0.000001333 V 18:01:43 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158409111 Vs 18:01:43 Integrated Voltage Measurement... 18:02:05 Voltage Offset Correction: v_off_ini = 0.000002475 V, v_off_fin = -0.000000513 V 18:02:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158466520 Vs 18:02:19 Temperature Measurement, Probe Number = 0, T = 20.189000 C 18:02:19 Temperature Measurement, Probe Number = 1, T = 20.104000 C 18:02:20 Temperature Measurement, Probe Number = 2, T = 20.143000 C 18:02:21 Temperature Measurement, Probe Number = 3, T = 20.084000 C 18:02:21 Temperature Measurement, Probe Number = 4, T = 20.115000 C 18:02:22 Temperature Measurement, Probe Number = 5, T = 20.063000 C 18:02:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 18:02:22 Integrated Voltage Measurement... 18:02:44 Voltage Offset Correction: v_off_ini = 0.000001508 V, v_off_fin = -0.000001743 V 18:02:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422967 Vs 18:02:44 Integrated Voltage Measurement... 18:03:06 Voltage Offset Correction: v_off_ini = -0.000001787 V, v_off_fin = -0.000002607 V 18:03:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420223 Vs 18:03:20 Temperature Measurement, Probe Number = 0, T = 20.166000 C 18:03:20 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:03:21 Temperature Measurement, Probe Number = 2, T = 20.145000 C 18:03:22 Temperature Measurement, Probe Number = 3, T = 20.084000 C 18:03:22 Temperature Measurement, Probe Number = 4, T = 20.118000 C 18:03:23 Temperature Measurement, Probe Number = 5, T = 20.064000 C 18:03:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.06 18:03:23 Integrated Voltage Measurement... 18:03:45 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = 0.000000242 V 18:03:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422140 Vs 18:03:45 Integrated Voltage Measurement... 18:04:08 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000002431 V 18:04:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420287 Vs 18:04:22 Temperature Measurement, Probe Number = 0, T = 20.166000 C 18:04:22 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:04:23 Temperature Measurement, Probe Number = 2, T = 20.141000 C 18:04:23 Temperature Measurement, Probe Number = 3, T = 20.082000 C 18:04:24 Temperature Measurement, Probe Number = 4, T = 20.115000 C 18:04:25 Temperature Measurement, Probe Number = 5, T = 20.063000 C 18:04:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 18:04:25 Integrated Voltage Measurement... 18:04:47 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000002203 V 18:04:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158453819 Vs 18:04:47 Integrated Voltage Measurement... 18:05:09 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = -0.000002701 V 18:05:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434920 Vs 18:05:23 Temperature Measurement, Probe Number = 0, T = 20.171000 C 18:05:23 Temperature Measurement, Probe Number = 1, T = 20.105000 C 18:05:24 Temperature Measurement, Probe Number = 2, T = 20.141000 C 18:05:25 Temperature Measurement, Probe Number = 3, T = 20.081000 C 18:05:25 Temperature Measurement, Probe Number = 4, T = 20.115000 C 18:05:26 Temperature Measurement, Probe Number = 5, T = 20.061000 C 18:05:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 18:05:26 Integrated Voltage Measurement... 18:05:48 Voltage Offset Correction: v_off_ini = 0.000000498 V, v_off_fin = 0.000000322 V 18:05:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424576 Vs 18:05:48 Integrated Voltage Measurement... 18:06:11 Voltage Offset Correction: v_off_ini = -0.000000454 V, v_off_fin = -0.000004326 V 18:06:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426968 Vs 19:02:24 Temperature Measurement, Probe Number = 0, T = 20.247000 C 19:02:25 Temperature Measurement, Probe Number = 1, T = 20.114000 C 19:02:25 Temperature Measurement, Probe Number = 2, T = 20.147000 C 19:02:26 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:02:27 Temperature Measurement, Probe Number = 4, T = 20.122000 C 19:02:27 Temperature Measurement, Probe Number = 5, T = 20.072000 C 19:02:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:02:27 Integrated Voltage Measurement... 19:02:50 Voltage Offset Correction: v_off_ini = -0.000000220 V, v_off_fin = 0.000000571 V 19:02:51 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.158460941 Vs 19:02:51 Integrated Voltage Measurement... 19:03:13 Voltage Offset Correction: v_off_ini = 0.000001786 V, v_off_fin = -0.000002825 V 19:03:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431320 Vs 19:03:27 Temperature Measurement, Probe Number = 0, T = 20.277000 C 19:03:27 Temperature Measurement, Probe Number = 1, T = 20.115000 C 19:03:28 Temperature Measurement, Probe Number = 2, T = 20.150000 C 19:03:29 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:03:29 Temperature Measurement, Probe Number = 4, T = 20.122000 C 19:03:30 Temperature Measurement, Probe Number = 5, T = 20.072000 C 19:03:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:03:30 Integrated Voltage Measurement... 19:03:52 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000002136 V 19:03:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422718 Vs 19:03:52 Integrated Voltage Measurement... 19:04:15 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000003930 V 19:04:15 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158370449 Vs 19:04:28 Temperature Measurement, Probe Number = 0, T = 20.262000 C 19:04:29 Temperature Measurement, Probe Number = 1, T = 20.114000 C 19:04:29 Temperature Measurement, Probe Number = 2, T = 20.151000 C 19:04:30 Temperature Measurement, Probe Number = 3, T = 20.102000 C 19:04:31 Temperature Measurement, Probe Number = 4, T = 20.122000 C 19:04:31 Temperature Measurement, Probe Number = 5, T = 20.073000 C 19:04:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:04:31 Integrated Voltage Measurement... 19:04:53 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001354 V 19:04:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158397527 Vs 19:04:53 Integrated Voltage Measurement... 19:05:16 Voltage Offset Correction: v_off_ini = 0.000001229 V, v_off_fin = -0.000003008 V 19:05:16 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158412215 Vs 19:05:30 Temperature Measurement, Probe Number = 0, T = 20.231000 C 19:05:30 Temperature Measurement, Probe Number = 1, T = 20.117000 C 19:05:31 Temperature Measurement, Probe Number = 2, T = 20.153000 C 19:05:32 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:05:32 Temperature Measurement, Probe Number = 4, T = 20.124000 C 19:05:33 Temperature Measurement, Probe Number = 5, T = 20.074000 C 19:05:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:05:33 Integrated Voltage Measurement... 19:05:55 Voltage Offset Correction: v_off_ini = -0.000000578 V, v_off_fin = -0.000000234 V 19:05:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415873 Vs 19:05:55 Integrated Voltage Measurement... 19:06:17 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000003256 V 19:06:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372252 Vs 19:06:31 Temperature Measurement, Probe Number = 0, T = 20.248000 C 19:06:31 Temperature Measurement, Probe Number = 1, T = 20.116000 C 19:06:32 Temperature Measurement, Probe Number = 2, T = 20.151000 C 19:06:33 Temperature Measurement, Probe Number = 3, T = 20.102000 C 19:06:33 Temperature Measurement, Probe Number = 4, T = 20.125000 C 19:06:34 Temperature Measurement, Probe Number = 5, T = 20.072000 C 19:06:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:06:34 Integrated Voltage Measurement... 19:06:56 Voltage Offset Correction: v_off_ini = -0.000002693 V, v_off_fin = -0.000002078 V 19:06:56 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158439496 Vs 19:06:56 Integrated Voltage Measurement... 19:07:18 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000004039 V 19:07:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158359070 Vs 19:07:32 Temperature Measurement, Probe Number = 0, T = 20.255000 C 19:07:33 Temperature Measurement, Probe Number = 1, T = 20.117000 C 19:07:33 Temperature Measurement, Probe Number = 2, T = 20.152000 C 19:07:34 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:07:35 Temperature Measurement, Probe Number = 4, T = 20.125000 C 19:07:35 Temperature Measurement, Probe Number = 5, T = 20.074000 C 19:07:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:07:35 Integrated Voltage Measurement... 19:07:57 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = 0.000001068 V 19:07:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158397477 Vs 19:07:57 Integrated Voltage Measurement... 19:08:20 Voltage Offset Correction: v_off_ini = -0.000001302 V, v_off_fin = -0.000001361 V 19:08:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380733 Vs 19:08:33 Temperature Measurement, Probe Number = 0, T = 20.250000 C 19:08:34 Temperature Measurement, Probe Number = 1, T = 20.119000 C 19:08:34 Temperature Measurement, Probe Number = 2, T = 20.153000 C 19:08:35 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:08:36 Temperature Measurement, Probe Number = 4, T = 20.127000 C 19:08:36 Temperature Measurement, Probe Number = 5, T = 20.075000 C 19:08:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 19:08:36 Integrated Voltage Measurement... 19:08:58 Voltage Offset Correction: v_off_ini = -0.000004251 V, v_off_fin = -0.000001595 V 19:08:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158426721 Vs 19:08:58 Integrated Voltage Measurement... 19:09:21 Voltage Offset Correction: v_off_ini = 0.000000658 V, v_off_fin = -0.000001097 V 19:09:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399722 Vs 19:09:34 Temperature Measurement, Probe Number = 0, T = 20.209000 C 19:09:35 Temperature Measurement, Probe Number = 1, T = 20.117000 C 19:09:35 Temperature Measurement, Probe Number = 2, T = 20.152000 C 19:09:36 Temperature Measurement, Probe Number = 3, T = 20.103000 C 19:09:37 Temperature Measurement, Probe Number = 4, T = 20.125000 C 19:09:37 Temperature Measurement, Probe Number = 5, T = 20.073000 C 19:09:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:09:37 Integrated Voltage Measurement... 19:09:59 Voltage Offset Correction: v_off_ini = -0.000002187 V, v_off_fin = -0.000003146 V 19:09:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446512 Vs 19:09:59 Integrated Voltage Measurement... 19:10:22 Voltage Offset Correction: v_off_ini = -0.000002370 V, v_off_fin = -0.000002685 V 19:10:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369078 Vs 19:10:35 Temperature Measurement, Probe Number = 0, T = 20.194000 C 19:10:36 Temperature Measurement, Probe Number = 1, T = 20.116000 C 19:10:37 Temperature Measurement, Probe Number = 2, T = 20.153000 C 19:10:37 Temperature Measurement, Probe Number = 3, T = 20.101000 C 19:10:38 Temperature Measurement, Probe Number = 4, T = 20.124000 C 19:10:38 Temperature Measurement, Probe Number = 5, T = 20.073000 C 19:10:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.12 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:10:38 Integrated Voltage Measurement... 19:11:01 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000000688 V 19:11:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158397625 Vs 19:11:01 Integrated Voltage Measurement... 19:11:23 Voltage Offset Correction: v_off_ini = -0.000000220 V, v_off_fin = -0.000001317 V 19:11:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398321 Vs 19:11:37 Temperature Measurement, Probe Number = 0, T = 20.150000 C 19:11:38 Temperature Measurement, Probe Number = 1, T = 20.113000 C 19:11:38 Temperature Measurement, Probe Number = 2, T = 20.149000 C 19:11:39 Temperature Measurement, Probe Number = 3, T = 20.100000 C 19:11:40 Temperature Measurement, Probe Number = 4, T = 20.123000 C 19:11:40 Temperature Measurement, Probe Number = 5, T = 20.073000 C 19:11:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.10 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 19:11:40 Integrated Voltage Measurement... 19:12:02 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000000995 V 19:12:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158396466 Vs 19:12:03 Integrated Voltage Measurement... 19:12:28 Voltage Offset Correction: v_off_ini = -0.000003695 V, v_off_fin = -0.000002956 V 19:12:28 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158334386 Vs 20:08:41 Temperature Measurement, Probe Number = 0, T = 20.128000 C 20:08:42 Temperature Measurement, Probe Number = 1, T = 20.111000 C 20:08:43 Temperature Measurement, Probe Number = 2, T = 20.144000 C 20:08:43 Temperature Measurement, Probe Number = 3, T = 20.091000 C 20:08:44 Temperature Measurement, Probe Number = 4, T = 20.122000 C 20:08:44 Temperature Measurement, Probe Number = 5, T = 20.072000 C 20:08:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:08:44 Integrated Voltage Measurement... 20:09:07 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001638 V 20:09:07 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.158422482 Vs 20:09:07 Integrated Voltage Measurement... 20:09:29 Voltage Offset Correction: v_off_ini = 0.000002194 V, v_off_fin = -0.000000168 V 20:09:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422292 Vs 20:09:43 Temperature Measurement, Probe Number = 0, T = 20.118000 C 20:09:43 Temperature Measurement, Probe Number = 1, T = 20.110000 C 20:09:44 Temperature Measurement, Probe Number = 2, T = 20.148000 C 20:09:45 Temperature Measurement, Probe Number = 3, T = 20.089000 C 20:09:45 Temperature Measurement, Probe Number = 4, T = 20.124000 C 20:09:46 Temperature Measurement, Probe Number = 5, T = 20.072000 C 20:09:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:09:46 Integrated Voltage Measurement... 20:10:08 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = -0.000001149 V 20:10:08 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158394560 Vs 20:10:08 Integrated Voltage Measurement... 20:10:30 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = -0.000002458 V 20:10:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376368 Vs 20:10:44 Temperature Measurement, Probe Number = 0, T = 20.098000 C 20:10:44 Temperature Measurement, Probe Number = 1, T = 20.115000 C 20:10:45 Temperature Measurement, Probe Number = 2, T = 20.149000 C 20:10:46 Temperature Measurement, Probe Number = 3, T = 20.090000 C 20:10:46 Temperature Measurement, Probe Number = 4, T = 20.125000 C 20:10:47 Temperature Measurement, Probe Number = 5, T = 20.074000 C 20:10:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:10:47 Integrated Voltage Measurement... 20:11:09 Voltage Offset Correction: v_off_ini = -0.000002348 V, v_off_fin = -0.000000885 V 20:11:09 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158407945 Vs 20:11:09 Integrated Voltage Measurement... 20:11:31 Voltage Offset Correction: v_off_ini = -0.000004075 V, v_off_fin = -0.000001880 V 20:11:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158343881 Vs 20:11:45 Temperature Measurement, Probe Number = 0, T = 20.081000 C 20:11:45 Temperature Measurement, Probe Number = 1, T = 20.112000 C 20:11:46 Temperature Measurement, Probe Number = 2, T = 20.150000 C 20:11:47 Temperature Measurement, Probe Number = 3, T = 20.092000 C 20:11:47 Temperature Measurement, Probe Number = 4, T = 20.125000 C 20:11:48 Temperature Measurement, Probe Number = 5, T = 20.072000 C 20:11:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:11:48 Integrated Voltage Measurement... 20:12:10 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001170 V 20:12:10 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158403640 Vs 20:12:10 Integrated Voltage Measurement... 20:12:33 Voltage Offset Correction: v_off_ini = -0.000000241 V, v_off_fin = -0.000001112 V 20:12:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158377426 Vs 20:12:46 Temperature Measurement, Probe Number = 0, T = 20.088000 C 20:12:47 Temperature Measurement, Probe Number = 1, T = 20.111000 C 20:12:47 Temperature Measurement, Probe Number = 2, T = 20.145000 C 20:12:48 Temperature Measurement, Probe Number = 3, T = 20.088000 C 20:12:49 Temperature Measurement, Probe Number = 4, T = 20.125000 C 20:12:49 Temperature Measurement, Probe Number = 5, T = 20.074000 C 20:12:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:12:49 Integrated Voltage Measurement... 20:13:11 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000001434 V 20:13:11 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158402814 Vs 20:13:11 Integrated Voltage Measurement... 20:13:34 Voltage Offset Correction: v_off_ini = 0.000000015 V, v_off_fin = -0.000001375 V 20:13:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388707 Vs 20:13:47 Temperature Measurement, Probe Number = 0, T = 20.124000 C 20:13:48 Temperature Measurement, Probe Number = 1, T = 20.111000 C 20:13:48 Temperature Measurement, Probe Number = 2, T = 20.145000 C 20:13:49 Temperature Measurement, Probe Number = 3, T = 20.094000 C 20:13:50 Temperature Measurement, Probe Number = 4, T = 20.122000 C 20:13:50 Temperature Measurement, Probe Number = 5, T = 20.072000 C 20:13:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:13:50 Integrated Voltage Measurement... 20:14:12 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000002517 V 20:14:13 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158412469 Vs 20:14:13 Integrated Voltage Measurement... 20:14:35 Voltage Offset Correction: v_off_ini = -0.000001720 V, v_off_fin = -0.000003285 V 20:14:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366225 Vs 20:14:49 Temperature Measurement, Probe Number = 0, T = 20.147000 C 20:14:49 Temperature Measurement, Probe Number = 1, T = 20.112000 C 20:14:50 Temperature Measurement, Probe Number = 2, T = 20.147000 C 20:14:50 Temperature Measurement, Probe Number = 3, T = 20.094000 C 20:14:51 Temperature Measurement, Probe Number = 4, T = 20.124000 C 20:14:52 Temperature Measurement, Probe Number = 5, T = 20.074000 C 20:14:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:14:52 Integrated Voltage Measurement... 20:15:14 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = 0.000000293 V 20:15:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158385238 Vs 20:15:15 Integrated Voltage Measurement... 20:15:37 Voltage Offset Correction: v_off_ini = -0.000002231 V, v_off_fin = -0.000002560 V 20:15:37 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158350881 Vs 20:15:51 Temperature Measurement, Probe Number = 0, T = 20.151000 C 20:15:51 Temperature Measurement, Probe Number = 1, T = 20.114000 C 20:15:52 Temperature Measurement, Probe Number = 2, T = 20.150000 C 20:15:53 Temperature Measurement, Probe Number = 3, T = 20.092000 C 20:15:53 Temperature Measurement, Probe Number = 4, T = 20.127000 C 20:15:54 Temperature Measurement, Probe Number = 5, T = 20.074000 C 20:15:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.13 P6 = Top_Jaw, Value = 20.07 20:15:54 Integrated Voltage Measurement... 20:16:16 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = 0.000000432 V 20:16:16 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158388725 Vs 20:16:16 Integrated Voltage Measurement... 20:16:38 Voltage Offset Correction: v_off_ini = 0.000001127 V, v_off_fin = -0.000002297 V 20:16:38 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158404147 Vs 20:16:52 Temperature Measurement, Probe Number = 0, T = 20.125000 C 20:16:52 Temperature Measurement, Probe Number = 1, T = 20.112000 C 20:16:53 Temperature Measurement, Probe Number = 2, T = 20.148000 C 20:16:54 Temperature Measurement, Probe Number = 3, T = 20.092000 C 20:16:54 Temperature Measurement, Probe Number = 4, T = 20.123000 C 20:16:55 Temperature Measurement, Probe Number = 5, T = 20.073000 C 20:16:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:16:55 Integrated Voltage Measurement... 20:17:17 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = 0.000001134 V 20:17:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158384511 Vs 20:17:17 Integrated Voltage Measurement... 20:17:39 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000000739 V 20:17:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383368 Vs 20:17:53 Temperature Measurement, Probe Number = 0, T = 20.127000 C 20:17:54 Temperature Measurement, Probe Number = 1, T = 20.112000 C 20:17:54 Temperature Measurement, Probe Number = 2, T = 20.150000 C 20:17:55 Temperature Measurement, Probe Number = 3, T = 20.093000 C 20:17:55 Temperature Measurement, Probe Number = 4, T = 20.123000 C 20:17:56 Temperature Measurement, Probe Number = 5, T = 20.072000 C 20:17:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.09 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 20:17:56 Integrated Voltage Measurement... 20:18:19 Voltage Offset Correction: v_off_ini = -0.000002730 V, v_off_fin = 0.000000146 V 20:18:19 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158395275 Vs 20:18:19 Integrated Voltage Measurement... 20:18:41 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000000629 V 20:18:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374210 Vs 21:14:55 Temperature Measurement, Probe Number = 0, T = 20.063000 C 21:14:56 Temperature Measurement, Probe Number = 1, T = 20.108000 C 21:14:56 Temperature Measurement, Probe Number = 2, T = 20.146000 C 21:14:57 Temperature Measurement, Probe Number = 3, T = 20.079000 C 21:14:58 Temperature Measurement, Probe Number = 4, T = 20.122000 C 21:14:58 Temperature Measurement, Probe Number = 5, T = 20.068000 C 21:14:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:14:58 Integrated Voltage Measurement... 21:15:21 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000000651 V 21:15:21 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158421846 Vs 21:15:21 Integrated Voltage Measurement... 21:15:43 Voltage Offset Correction: v_off_ini = 0.000000614 V, v_off_fin = -0.000004301 V 21:15:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364699 Vs 21:15:57 Temperature Measurement, Probe Number = 0, T = 20.101000 C 21:15:58 Temperature Measurement, Probe Number = 1, T = 20.107000 C 21:15:58 Temperature Measurement, Probe Number = 2, T = 20.145000 C 21:15:59 Temperature Measurement, Probe Number = 3, T = 20.081000 C 21:15:59 Temperature Measurement, Probe Number = 4, T = 20.121000 C 21:16:00 Temperature Measurement, Probe Number = 5, T = 20.068000 C 21:16:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:16:00 Integrated Voltage Measurement... 21:16:22 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000001119 V 21:16:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393152 Vs 21:16:22 Integrated Voltage Measurement... 21:16:44 Voltage Offset Correction: v_off_ini = -0.000000702 V, v_off_fin = -0.000002662 V 21:16:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374620 Vs 21:16:58 Temperature Measurement, Probe Number = 0, T = 20.122000 C 21:16:59 Temperature Measurement, Probe Number = 1, T = 20.105000 C 21:16:59 Temperature Measurement, Probe Number = 2, T = 20.146000 C 21:17:00 Temperature Measurement, Probe Number = 3, T = 20.080000 C 21:17:01 Temperature Measurement, Probe Number = 4, T = 20.122000 C 21:17:01 Temperature Measurement, Probe Number = 5, T = 20.067000 C 21:17:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:17:01 Integrated Voltage Measurement... 21:17:23 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000446 V 21:17:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158385103 Vs 21:17:23 Integrated Voltage Measurement... 21:17:46 Voltage Offset Correction: v_off_ini = 0.000001309 V, v_off_fin = -0.000002034 V 21:17:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381309 Vs 21:18:00 Temperature Measurement, Probe Number = 0, T = 20.096000 C 21:18:01 Temperature Measurement, Probe Number = 1, T = 20.111000 C 21:18:01 Temperature Measurement, Probe Number = 2, T = 20.147000 C 21:18:02 Temperature Measurement, Probe Number = 3, T = 20.078000 C 21:18:03 Temperature Measurement, Probe Number = 4, T = 20.124000 C 21:18:03 Temperature Measurement, Probe Number = 5, T = 20.070000 C 21:18:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:18:03 Integrated Voltage Measurement... 21:18:25 Voltage Offset Correction: v_off_ini = -0.000002209 V, v_off_fin = -0.000001412 V 21:18:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158413197 Vs 21:18:26 Integrated Voltage Measurement... 21:18:48 Voltage Offset Correction: v_off_ini = 0.000001295 V, v_off_fin = -0.000003540 V 21:18:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391620 Vs 21:19:02 Temperature Measurement, Probe Number = 0, T = 20.107000 C 21:19:03 Temperature Measurement, Probe Number = 1, T = 20.108000 C 21:19:03 Temperature Measurement, Probe Number = 2, T = 20.148000 C 21:19:04 Temperature Measurement, Probe Number = 3, T = 20.079000 C 21:19:04 Temperature Measurement, Probe Number = 4, T = 20.123000 C 21:19:05 Temperature Measurement, Probe Number = 5, T = 20.068000 C 21:19:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:19:05 Integrated Voltage Measurement... 21:19:27 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000000059 V 21:19:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158389345 Vs 21:19:27 Integrated Voltage Measurement... 21:19:49 Voltage Offset Correction: v_off_ini = -0.000003761 V, v_off_fin = -0.000003673 V 21:19:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158341499 Vs 21:20:03 Temperature Measurement, Probe Number = 0, T = 20.136000 C 21:20:04 Temperature Measurement, Probe Number = 1, T = 20.107000 C 21:20:04 Temperature Measurement, Probe Number = 2, T = 20.147000 C 21:20:05 Temperature Measurement, Probe Number = 3, T = 20.080000 C 21:20:05 Temperature Measurement, Probe Number = 4, T = 20.122000 C 21:20:06 Temperature Measurement, Probe Number = 5, T = 20.069000 C 21:20:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:20:06 Integrated Voltage Measurement... 21:20:28 Voltage Offset Correction: v_off_ini = -0.000001887 V, v_off_fin = -0.000000622 V 21:20:28 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158395947 Vs 21:20:28 Integrated Voltage Measurement... 21:20:50 Voltage Offset Correction: v_off_ini = 0.000002209 V, v_off_fin = -0.000001609 V 21:20:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158406016 Vs 21:21:04 Temperature Measurement, Probe Number = 0, T = 20.125000 C 21:21:05 Temperature Measurement, Probe Number = 1, T = 20.105000 C 21:21:05 Temperature Measurement, Probe Number = 2, T = 20.144000 C 21:21:06 Temperature Measurement, Probe Number = 3, T = 20.080000 C 21:21:06 Temperature Measurement, Probe Number = 4, T = 20.119000 C 21:21:07 Temperature Measurement, Probe Number = 5, T = 20.068000 C 21:21:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:21:07 Integrated Voltage Measurement... 21:21:29 Voltage Offset Correction: v_off_ini = -0.000002267 V, v_off_fin = -0.000000958 V 21:21:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400934 Vs 21:21:29 Integrated Voltage Measurement... 21:21:51 Voltage Offset Correction: v_off_ini = -0.000000293 V, v_off_fin = -0.000001521 V 21:21:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382606 Vs 21:22:05 Temperature Measurement, Probe Number = 0, T = 20.138000 C 21:22:05 Temperature Measurement, Probe Number = 1, T = 20.108000 C 21:22:06 Temperature Measurement, Probe Number = 2, T = 20.147000 C 21:22:07 Temperature Measurement, Probe Number = 3, T = 20.080000 C 21:22:07 Temperature Measurement, Probe Number = 4, T = 20.122000 C 21:22:08 Temperature Measurement, Probe Number = 5, T = 20.069000 C 21:22:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:22:08 Integrated Voltage Measurement... 21:22:30 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000003423 V 21:22:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407076 Vs 21:22:30 Integrated Voltage Measurement... 21:22:53 Voltage Offset Correction: v_off_ini = -0.000000497 V, v_off_fin = -0.000002187 V 21:22:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374200 Vs 21:23:06 Temperature Measurement, Probe Number = 0, T = 20.133000 C 21:23:07 Temperature Measurement, Probe Number = 1, T = 20.111000 C 21:23:07 Temperature Measurement, Probe Number = 2, T = 20.149000 C 21:23:08 Temperature Measurement, Probe Number = 3, T = 20.079000 C 21:23:09 Temperature Measurement, Probe Number = 4, T = 20.123000 C 21:23:09 Temperature Measurement, Probe Number = 5, T = 20.070000 C 21:23:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:23:09 Integrated Voltage Measurement... 21:23:31 Voltage Offset Correction: v_off_ini = -0.000001653 V, v_off_fin = -0.000000797 V 21:23:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393773 Vs 21:23:31 Integrated Voltage Measurement... 21:23:54 Voltage Offset Correction: v_off_ini = 0.000000732 V, v_off_fin = -0.000002839 V 21:23:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389044 Vs 21:24:07 Temperature Measurement, Probe Number = 0, T = 20.100000 C 21:24:08 Temperature Measurement, Probe Number = 1, T = 20.114000 C 21:24:08 Temperature Measurement, Probe Number = 2, T = 20.147000 C 21:24:09 Temperature Measurement, Probe Number = 3, T = 20.079000 C 21:24:10 Temperature Measurement, Probe Number = 4, T = 20.123000 C 21:24:10 Temperature Measurement, Probe Number = 5, T = 20.071000 C 21:24:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.15 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 21:24:10 Integrated Voltage Measurement... 21:24:33 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000002165 V 21:24:33 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158415278 Vs 21:24:33 Integrated Voltage Measurement... 21:24:55 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000001463 V 21:24:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158377835 Vs 22:21:09 Temperature Measurement, Probe Number = 0, T = 20.105000 C 22:21:09 Temperature Measurement, Probe Number = 1, T = 20.104000 C 22:21:10 Temperature Measurement, Probe Number = 2, T = 20.142000 C 22:21:10 Temperature Measurement, Probe Number = 3, T = 20.074000 C 22:21:11 Temperature Measurement, Probe Number = 4, T = 20.119000 C 22:21:12 Temperature Measurement, Probe Number = 5, T = 20.066000 C 22:21:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:21:12 Integrated Voltage Measurement... 22:21:34 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = 0.000000234 V 22:21:34 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158425822 Vs 22:21:34 Integrated Voltage Measurement... 22:21:56 Voltage Offset Correction: v_off_ini = 0.000000585 V, v_off_fin = -0.000002341 V 22:21:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158363664 Vs 22:22:10 Temperature Measurement, Probe Number = 0, T = 20.089000 C 22:22:10 Temperature Measurement, Probe Number = 1, T = 20.109000 C 22:22:11 Temperature Measurement, Probe Number = 2, T = 20.142000 C 22:22:11 Temperature Measurement, Probe Number = 3, T = 20.073000 C 22:22:12 Temperature Measurement, Probe Number = 4, T = 20.120000 C 22:22:13 Temperature Measurement, Probe Number = 5, T = 20.068000 C 22:22:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:22:13 Integrated Voltage Measurement... 22:22:35 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = 0.000000812 V 22:22:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158347603 Vs 22:22:35 Integrated Voltage Measurement... 22:22:57 Voltage Offset Correction: v_off_ini = 0.000001083 V, v_off_fin = -0.000000798 V 22:22:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378443 Vs 22:23:11 Temperature Measurement, Probe Number = 0, T = 20.098000 C 22:23:11 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:23:12 Temperature Measurement, Probe Number = 2, T = 20.144000 C 22:23:12 Temperature Measurement, Probe Number = 3, T = 20.069000 C 22:23:13 Temperature Measurement, Probe Number = 4, T = 20.119000 C 22:23:14 Temperature Measurement, Probe Number = 5, T = 20.068000 C 22:23:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:23:14 Integrated Voltage Measurement... 22:23:36 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000001346 V 22:23:36 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158380445 Vs 22:23:36 Integrated Voltage Measurement... 22:23:58 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = -0.000003693 V 22:23:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158352941 Vs 22:24:12 Temperature Measurement, Probe Number = 0, T = 20.110000 C 22:24:12 Temperature Measurement, Probe Number = 1, T = 20.111000 C 22:24:13 Temperature Measurement, Probe Number = 2, T = 20.144000 C 22:24:14 Temperature Measurement, Probe Number = 3, T = 20.072000 C 22:24:14 Temperature Measurement, Probe Number = 4, T = 20.120000 C 22:24:15 Temperature Measurement, Probe Number = 5, T = 20.068000 C 22:24:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:24:15 Integrated Voltage Measurement... 22:24:38 Voltage Offset Correction: v_off_ini = -0.000003285 V, v_off_fin = -0.000001273 V 22:24:38 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158400619 Vs 22:24:38 Integrated Voltage Measurement... 22:25:00 Voltage Offset Correction: v_off_ini = -0.000000402 V, v_off_fin = -0.000001858 V 22:25:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374573 Vs 22:25:14 Temperature Measurement, Probe Number = 0, T = 20.089000 C 22:25:14 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:25:15 Temperature Measurement, Probe Number = 2, T = 20.143000 C 22:25:16 Temperature Measurement, Probe Number = 3, T = 20.071000 C 22:25:16 Temperature Measurement, Probe Number = 4, T = 20.119000 C 22:25:17 Temperature Measurement, Probe Number = 5, T = 20.067000 C 22:25:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:25:17 Integrated Voltage Measurement... 22:25:39 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000002691 V 22:25:39 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158388678 Vs 22:25:39 Integrated Voltage Measurement... 22:26:01 Voltage Offset Correction: v_off_ini = 0.000000219 V, v_off_fin = -0.000000826 V 22:26:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382745 Vs 22:26:15 Temperature Measurement, Probe Number = 0, T = 20.068000 C 22:26:16 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:26:16 Temperature Measurement, Probe Number = 2, T = 20.143000 C 22:26:17 Temperature Measurement, Probe Number = 3, T = 20.071000 C 22:26:17 Temperature Measurement, Probe Number = 4, T = 20.120000 C 22:26:18 Temperature Measurement, Probe Number = 5, T = 20.068000 C 22:26:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:26:18 Integrated Voltage Measurement... 22:26:40 Voltage Offset Correction: v_off_ini = -0.000002516 V, v_off_fin = -0.000001639 V 22:26:40 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158386596 Vs 22:26:40 Integrated Voltage Measurement... 22:27:02 Voltage Offset Correction: v_off_ini = 0.000000534 V, v_off_fin = -0.000003189 V 22:27:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158337208 Vs 22:27:16 Temperature Measurement, Probe Number = 0, T = 20.070000 C 22:27:17 Temperature Measurement, Probe Number = 1, T = 20.109000 C 22:27:17 Temperature Measurement, Probe Number = 2, T = 20.145000 C 22:27:18 Temperature Measurement, Probe Number = 3, T = 20.072000 C 22:27:18 Temperature Measurement, Probe Number = 4, T = 20.120000 C 22:27:19 Temperature Measurement, Probe Number = 5, T = 20.067000 C 22:27:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:27:19 Integrated Voltage Measurement... 22:27:42 Voltage Offset Correction: v_off_ini = -0.000001763 V, v_off_fin = 0.000000366 V 22:27:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158385206 Vs 22:27:42 Integrated Voltage Measurement... 22:28:04 Voltage Offset Correction: v_off_ini = -0.000001587 V, v_off_fin = -0.000003013 V 22:28:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158343157 Vs 22:28:18 Temperature Measurement, Probe Number = 0, T = 20.130000 C 22:28:19 Temperature Measurement, Probe Number = 1, T = 20.110000 C 22:28:19 Temperature Measurement, Probe Number = 2, T = 20.145000 C 22:28:20 Temperature Measurement, Probe Number = 3, T = 20.073000 C 22:28:20 Temperature Measurement, Probe Number = 4, T = 20.121000 C 22:28:21 Temperature Measurement, Probe Number = 5, T = 20.069000 C 22:28:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:28:21 Integrated Voltage Measurement... 22:28:43 Voltage Offset Correction: v_off_ini = -0.000000966 V, v_off_fin = 0.000000146 V 22:28:43 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158367970 Vs 22:28:43 Integrated Voltage Measurement... 22:29:05 Voltage Offset Correction: v_off_ini = 0.000000424 V, v_off_fin = -0.000001946 V 22:29:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379072 Vs 22:29:19 Temperature Measurement, Probe Number = 0, T = 20.115000 C 22:29:19 Temperature Measurement, Probe Number = 1, T = 20.109000 C 22:29:20 Temperature Measurement, Probe Number = 2, T = 20.145000 C 22:29:21 Temperature Measurement, Probe Number = 3, T = 20.069000 C 22:29:21 Temperature Measurement, Probe Number = 4, T = 20.121000 C 22:29:22 Temperature Measurement, Probe Number = 5, T = 20.067000 C 22:29:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:29:22 Integrated Voltage Measurement... 22:29:44 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000000761 V 22:29:44 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158380977 Vs 22:29:44 Integrated Voltage Measurement... 22:30:06 Voltage Offset Correction: v_off_ini = 0.000000709 V, v_off_fin = -0.000001426 V 22:30:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158363503 Vs 22:30:20 Temperature Measurement, Probe Number = 0, T = 20.086000 C 22:30:21 Temperature Measurement, Probe Number = 1, T = 20.107000 C 22:30:21 Temperature Measurement, Probe Number = 2, T = 20.144000 C 22:30:22 Temperature Measurement, Probe Number = 3, T = 20.072000 C 22:30:22 Temperature Measurement, Probe Number = 4, T = 20.118000 C 22:30:23 Temperature Measurement, Probe Number = 5, T = 20.067000 C 22:30:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.12 P6 = Top_Jaw, Value = 20.07 22:30:23 Integrated Voltage Measurement... 22:30:45 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000029 V 22:30:45 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158375857 Vs 22:30:45 Integrated Voltage Measurement... 22:31:07 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000003101 V 22:31:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158355342 Vs 23:27:21 Temperature Measurement, Probe Number = 0, T = 20.098000 C 23:27:22 Temperature Measurement, Probe Number = 1, T = 20.103000 C 23:27:22 Temperature Measurement, Probe Number = 2, T = 20.134000 C 23:27:23 Temperature Measurement, Probe Number = 3, T = 20.068000 C 23:27:23 Temperature Measurement, Probe Number = 4, T = 20.112000 C 23:27:24 Temperature Measurement, Probe Number = 5, T = 20.064000 C 23:27:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:27:24 Integrated Voltage Measurement... 23:27:46 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000000995 V 23:27:46 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158405860 Vs 23:27:46 Integrated Voltage Measurement... 23:28:08 Voltage Offset Correction: v_off_ini = -0.000000249 V, v_off_fin = -0.000002137 V 23:28:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364453 Vs 23:28:22 Temperature Measurement, Probe Number = 0, T = 20.084000 C 23:28:23 Temperature Measurement, Probe Number = 1, T = 20.104000 C 23:28:23 Temperature Measurement, Probe Number = 2, T = 20.134000 C 23:28:24 Temperature Measurement, Probe Number = 3, T = 20.066000 C 23:28:24 Temperature Measurement, Probe Number = 4, T = 20.112000 C 23:28:25 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:28:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.07 23:28:25 Integrated Voltage Measurement... 23:28:48 Voltage Offset Correction: v_off_ini = -0.000001880 V, v_off_fin = -0.000001068 V 23:28:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395091 Vs 23:28:48 Integrated Voltage Measurement... 23:29:10 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000001624 V 23:29:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372381 Vs 23:29:24 Temperature Measurement, Probe Number = 0, T = 20.088000 C 23:29:24 Temperature Measurement, Probe Number = 1, T = 20.104000 C 23:29:25 Temperature Measurement, Probe Number = 2, T = 20.134000 C 23:29:26 Temperature Measurement, Probe Number = 3, T = 20.069000 C 23:29:26 Temperature Measurement, Probe Number = 4, T = 20.113000 C 23:29:27 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:29:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.07 23:29:27 Integrated Voltage Measurement... 23:29:49 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000000673 V 23:29:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158375349 Vs 23:29:50 Integrated Voltage Measurement... 23:30:12 Voltage Offset Correction: v_off_ini = -0.000000344 V, v_off_fin = -0.000002283 V 23:30:12 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158386504 Vs 23:30:26 Temperature Measurement, Probe Number = 0, T = 20.102000 C 23:30:26 Temperature Measurement, Probe Number = 1, T = 20.107000 C 23:30:27 Temperature Measurement, Probe Number = 2, T = 20.134000 C 23:30:28 Temperature Measurement, Probe Number = 3, T = 20.069000 C 23:30:28 Temperature Measurement, Probe Number = 4, T = 20.112000 C 23:30:29 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:30:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.07 23:30:29 Integrated Voltage Measurement... 23:30:51 Voltage Offset Correction: v_off_ini = -0.000001991 V, v_off_fin = -0.000001559 V 23:30:51 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158410593 Vs 23:30:51 Integrated Voltage Measurement... 23:31:13 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = -0.000002635 V 23:31:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361127 Vs 23:31:27 Temperature Measurement, Probe Number = 0, T = 20.121000 C 23:31:28 Temperature Measurement, Probe Number = 1, T = 20.105000 C 23:31:28 Temperature Measurement, Probe Number = 2, T = 20.136000 C 23:31:29 Temperature Measurement, Probe Number = 3, T = 20.066000 C 23:31:29 Temperature Measurement, Probe Number = 4, T = 20.112000 C 23:31:30 Temperature Measurement, Probe Number = 5, T = 20.063000 C 23:31:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:31:30 Integrated Voltage Measurement... 23:31:52 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = 0.000000190 V 23:31:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158371706 Vs 23:31:52 Integrated Voltage Measurement... 23:32:14 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000003600 V 23:32:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158362772 Vs 23:32:28 Temperature Measurement, Probe Number = 0, T = 20.103000 C 23:32:29 Temperature Measurement, Probe Number = 1, T = 20.105000 C 23:32:29 Temperature Measurement, Probe Number = 2, T = 20.134000 C 23:32:30 Temperature Measurement, Probe Number = 3, T = 20.066000 C 23:32:30 Temperature Measurement, Probe Number = 4, T = 20.111000 C 23:32:31 Temperature Measurement, Probe Number = 5, T = 20.065000 C 23:32:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.11 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.07 23:32:31 Integrated Voltage Measurement... 23:33:00 Voltage Offset Correction: v_off_ini = -0.000002254 V, v_off_fin = -0.000001120 V 23:33:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393292 Vs 23:33:00 Integrated Voltage Measurement... 23:33:22 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = -0.000002151 V 23:33:22 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158358315 Vs 23:33:36 Temperature Measurement, Probe Number = 0, T = 20.080000 C 23:33:36 Temperature Measurement, Probe Number = 1, T = 20.102000 C 23:33:37 Temperature Measurement, Probe Number = 2, T = 20.133000 C 23:33:37 Temperature Measurement, Probe Number = 3, T = 20.066000 C 23:33:38 Temperature Measurement, Probe Number = 4, T = 20.112000 C 23:33:39 Temperature Measurement, Probe Number = 5, T = 20.064000 C 23:33:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:33:39 Integrated Voltage Measurement... 23:34:01 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000000717 V 23:34:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158397859 Vs 23:34:01 Integrated Voltage Measurement... 23:34:23 Voltage Offset Correction: v_off_ini = -0.000000659 V, v_off_fin = -0.000003044 V 23:34:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158352509 Vs 23:34:37 Temperature Measurement, Probe Number = 0, T = 20.078000 C 23:34:37 Temperature Measurement, Probe Number = 1, T = 20.104000 C 23:34:38 Temperature Measurement, Probe Number = 2, T = 20.135000 C 23:34:39 Temperature Measurement, Probe Number = 3, T = 20.066000 C 23:34:39 Temperature Measurement, Probe Number = 4, T = 20.111000 C 23:34:40 Temperature Measurement, Probe Number = 5, T = 20.064000 C 23:34:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:34:40 Integrated Voltage Measurement... 23:35:02 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000001902 V 23:35:02 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382020 Vs 23:35:02 Integrated Voltage Measurement... 23:35:25 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000004537 V 23:35:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158340748 Vs 23:35:38 Temperature Measurement, Probe Number = 0, T = 20.093000 C 23:35:39 Temperature Measurement, Probe Number = 1, T = 20.103000 C 23:35:39 Temperature Measurement, Probe Number = 2, T = 20.135000 C 23:35:40 Temperature Measurement, Probe Number = 3, T = 20.067000 C 23:35:41 Temperature Measurement, Probe Number = 4, T = 20.110000 C 23:35:41 Temperature Measurement, Probe Number = 5, T = 20.063000 C 23:35:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.14 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:35:41 Integrated Voltage Measurement... 23:36:03 Voltage Offset Correction: v_off_ini = -0.000003174 V, v_off_fin = -0.000001463 V 23:36:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405828 Vs 23:36:03 Integrated Voltage Measurement... 23:36:26 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000001171 V 23:36:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366074 Vs 23:36:39 Temperature Measurement, Probe Number = 0, T = 20.078000 C 23:36:40 Temperature Measurement, Probe Number = 1, T = 20.102000 C 23:36:40 Temperature Measurement, Probe Number = 2, T = 20.133000 C 23:36:41 Temperature Measurement, Probe Number = 3, T = 20.065000 C 23:36:42 Temperature Measurement, Probe Number = 4, T = 20.110000 C 23:36:42 Temperature Measurement, Probe Number = 5, T = 20.063000 C 23:36:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.11 P6 = Top_Jaw, Value = 20.06 23:36:42 Integrated Voltage Measurement... 23:37:04 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000000965 V 23:37:04 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158388298 Vs 23:37:04 Integrated Voltage Measurement... 23:37:27 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000002407 V 23:37:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366921 Vs 00:33:40 Temperature Measurement, Probe Number = 0, T = 20.021000 C 00:33:41 Temperature Measurement, Probe Number = 1, T = 20.097000 C 00:33:41 Temperature Measurement, Probe Number = 2, T = 20.122000 C 00:33:42 Temperature Measurement, Probe Number = 3, T = 20.036000 C 00:33:43 Temperature Measurement, Probe Number = 4, T = 20.099000 C 00:33:43 Temperature Measurement, Probe Number = 5, T = 20.056000 C 00:33:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.06 00:33:43 Integrated Voltage Measurement... 00:34:06 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000002019 V 00:34:06 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158418760 Vs 00:34:06 Integrated Voltage Measurement... 00:34:28 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = -0.000001434 V 00:34:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366991 Vs 00:34:42 Temperature Measurement, Probe Number = 0, T = 20.031000 C 00:34:43 Temperature Measurement, Probe Number = 1, T = 20.093000 C 00:34:43 Temperature Measurement, Probe Number = 2, T = 20.122000 C 00:34:44 Temperature Measurement, Probe Number = 3, T = 20.033000 C 00:34:44 Temperature Measurement, Probe Number = 4, T = 20.098000 C 00:34:45 Temperature Measurement, Probe Number = 5, T = 20.054000 C 00:34:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:34:45 Integrated Voltage Measurement... 00:35:07 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000000007 V 00:35:07 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158378478 Vs 00:35:07 Integrated Voltage Measurement... 00:35:29 Voltage Offset Correction: v_off_ini = -0.000003161 V, v_off_fin = -0.000002371 V 00:35:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158362817 Vs 00:35:43 Temperature Measurement, Probe Number = 0, T = 20.048000 C 00:35:44 Temperature Measurement, Probe Number = 1, T = 20.099000 C 00:35:44 Temperature Measurement, Probe Number = 2, T = 20.125000 C 00:35:45 Temperature Measurement, Probe Number = 3, T = 20.038000 C 00:35:46 Temperature Measurement, Probe Number = 4, T = 20.099000 C 00:35:46 Temperature Measurement, Probe Number = 5, T = 20.058000 C 00:35:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.06 00:35:46 Integrated Voltage Measurement... 00:36:08 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000000600 V 00:36:08 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158368256 Vs 00:36:08 Integrated Voltage Measurement... 00:36:31 Voltage Offset Correction: v_off_ini = 0.000000081 V, v_off_fin = -0.000001054 V 00:36:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366345 Vs 00:36:44 Temperature Measurement, Probe Number = 0, T = 20.041000 C 00:36:45 Temperature Measurement, Probe Number = 1, T = 20.094000 C 00:36:45 Temperature Measurement, Probe Number = 2, T = 20.125000 C 00:36:46 Temperature Measurement, Probe Number = 3, T = 20.037000 C 00:36:47 Temperature Measurement, Probe Number = 4, T = 20.098000 C 00:36:47 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:36:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:36:47 Integrated Voltage Measurement... 00:37:09 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000001573 V 00:37:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158390839 Vs 00:37:09 Integrated Voltage Measurement... 00:37:32 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = -0.000002642 V 00:37:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158346346 Vs 00:37:45 Temperature Measurement, Probe Number = 0, T = 20.030000 C 00:37:46 Temperature Measurement, Probe Number = 1, T = 20.093000 C 00:37:46 Temperature Measurement, Probe Number = 2, T = 20.126000 C 00:37:47 Temperature Measurement, Probe Number = 3, T = 20.036000 C 00:37:48 Temperature Measurement, Probe Number = 4, T = 20.098000 C 00:37:48 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:37:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.13 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:37:48 Integrated Voltage Measurement... 00:38:10 Voltage Offset Correction: v_off_ini = -0.000001369 V, v_off_fin = -0.000002862 V 00:38:10 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158407215 Vs 00:38:10 Integrated Voltage Measurement... 00:38:33 Voltage Offset Correction: v_off_ini = -0.000001486 V, v_off_fin = -0.000002847 V 00:38:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158352245 Vs 00:38:47 Temperature Measurement, Probe Number = 0, T = 20.015000 C 00:38:48 Temperature Measurement, Probe Number = 1, T = 20.091000 C 00:38:48 Temperature Measurement, Probe Number = 2, T = 20.121000 C 00:38:49 Temperature Measurement, Probe Number = 3, T = 20.037000 C 00:38:50 Temperature Measurement, Probe Number = 4, T = 20.096000 C 00:38:50 Temperature Measurement, Probe Number = 5, T = 20.054000 C 00:38:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:38:50 Integrated Voltage Measurement... 00:39:12 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = 0.000000673 V 00:39:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158383967 Vs 00:39:13 Integrated Voltage Measurement... 00:39:35 Voltage Offset Correction: v_off_ini = -0.000001010 V, v_off_fin = -0.000001698 V 00:39:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374017 Vs 00:39:49 Temperature Measurement, Probe Number = 0, T = 20.048000 C 00:39:49 Temperature Measurement, Probe Number = 1, T = 20.093000 C 00:39:50 Temperature Measurement, Probe Number = 2, T = 20.117000 C 00:39:51 Temperature Measurement, Probe Number = 3, T = 20.039000 C 00:39:51 Temperature Measurement, Probe Number = 4, T = 20.096000 C 00:39:52 Temperature Measurement, Probe Number = 5, T = 20.054000 C 00:39:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:39:52 Integrated Voltage Measurement... 00:40:14 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000000476 V 00:40:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158399808 Vs 00:40:14 Integrated Voltage Measurement... 00:40:36 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002758 V 00:40:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158350248 Vs 00:40:50 Temperature Measurement, Probe Number = 0, T = 20.066000 C 00:40:50 Temperature Measurement, Probe Number = 1, T = 20.094000 C 00:40:51 Temperature Measurement, Probe Number = 2, T = 20.120000 C 00:40:52 Temperature Measurement, Probe Number = 3, T = 20.041000 C 00:40:52 Temperature Measurement, Probe Number = 4, T = 20.097000 C 00:40:53 Temperature Measurement, Probe Number = 5, T = 20.055000 C 00:40:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.05 00:40:53 Integrated Voltage Measurement... 00:41:15 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000000878 V 00:41:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158387274 Vs 00:41:15 Integrated Voltage Measurement... 00:41:38 Voltage Offset Correction: v_off_ini = -0.000000651 V, v_off_fin = -0.000001434 V 00:41:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364509 Vs 00:41:51 Temperature Measurement, Probe Number = 0, T = 20.085000 C 00:41:52 Temperature Measurement, Probe Number = 1, T = 20.096000 C 00:41:52 Temperature Measurement, Probe Number = 2, T = 20.121000 C 00:41:53 Temperature Measurement, Probe Number = 3, T = 20.043000 C 00:41:54 Temperature Measurement, Probe Number = 4, T = 20.096000 C 00:41:54 Temperature Measurement, Probe Number = 5, T = 20.056000 C 00:41:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.06 00:41:54 Integrated Voltage Measurement... 00:42:17 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = -0.000001844 V 00:42:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382986 Vs 00:42:17 Integrated Voltage Measurement... 00:42:39 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000003484 V 00:42:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364820 Vs 00:42:53 Temperature Measurement, Probe Number = 0, T = 20.124000 C 00:42:53 Temperature Measurement, Probe Number = 1, T = 20.099000 C 00:42:54 Temperature Measurement, Probe Number = 2, T = 20.122000 C 00:42:55 Temperature Measurement, Probe Number = 3, T = 20.045000 C 00:42:55 Temperature Measurement, Probe Number = 4, T = 20.098000 C 00:42:56 Temperature Measurement, Probe Number = 5, T = 20.056000 C 00:42:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.10 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.06 00:42:56 Integrated Voltage Measurement... 00:43:18 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = 0.000001083 V 00:43:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158364782 Vs 00:43:18 Integrated Voltage Measurement... 00:43:40 Voltage Offset Correction: v_off_ini = -0.000000183 V, v_off_fin = -0.000003930 V 00:43:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370038 Vs 01:39:54 Temperature Measurement, Probe Number = 0, T = 19.927000 C 01:39:55 Temperature Measurement, Probe Number = 1, T = 20.090000 C 01:39:55 Temperature Measurement, Probe Number = 2, T = 20.105000 C 01:39:56 Temperature Measurement, Probe Number = 3, T = 20.032000 C 01:39:56 Temperature Measurement, Probe Number = 4, T = 20.087000 C 01:39:57 Temperature Measurement, Probe Number = 5, T = 20.053000 C 01:39:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:39:57 Integrated Voltage Measurement... 01:40:19 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = 0.000002100 V 01:40:20 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158397469 Vs 01:40:20 Integrated Voltage Measurement... 01:40:42 Voltage Offset Correction: v_off_ini = -0.000002487 V, v_off_fin = -0.000002473 V 01:40:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158331241 Vs 01:40:55 Temperature Measurement, Probe Number = 0, T = 19.976000 C 01:40:56 Temperature Measurement, Probe Number = 1, T = 20.091000 C 01:40:56 Temperature Measurement, Probe Number = 2, T = 20.110000 C 01:40:57 Temperature Measurement, Probe Number = 3, T = 20.033000 C 01:40:58 Temperature Measurement, Probe Number = 4, T = 20.087000 C 01:40:58 Temperature Measurement, Probe Number = 5, T = 20.053000 C 01:40:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:40:58 Integrated Voltage Measurement... 01:41:21 Voltage Offset Correction: v_off_ini = -0.000001887 V, v_off_fin = -0.000000344 V 01:41:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158362595 Vs 01:41:21 Integrated Voltage Measurement... 01:41:43 Voltage Offset Correction: v_off_ini = -0.000000563 V, v_off_fin = -0.000002254 V 01:41:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366941 Vs 01:41:57 Temperature Measurement, Probe Number = 0, T = 20.026000 C 01:41:57 Temperature Measurement, Probe Number = 1, T = 20.091000 C 01:41:58 Temperature Measurement, Probe Number = 2, T = 20.109000 C 01:41:59 Temperature Measurement, Probe Number = 3, T = 20.034000 C 01:41:59 Temperature Measurement, Probe Number = 4, T = 20.088000 C 01:42:00 Temperature Measurement, Probe Number = 5, T = 20.052000 C 01:42:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:42:00 Integrated Voltage Measurement... 01:42:22 Voltage Offset Correction: v_off_ini = -0.000002020 V, v_off_fin = -0.000002232 V 01:42:22 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158404378 Vs 01:42:22 Integrated Voltage Measurement... 01:42:44 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = -0.000002531 V 01:42:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158348822 Vs 01:42:58 Temperature Measurement, Probe Number = 0, T = 20.002000 C 01:42:59 Temperature Measurement, Probe Number = 1, T = 20.090000 C 01:42:59 Temperature Measurement, Probe Number = 2, T = 20.105000 C 01:43:00 Temperature Measurement, Probe Number = 3, T = 20.033000 C 01:43:01 Temperature Measurement, Probe Number = 4, T = 20.087000 C 01:43:01 Temperature Measurement, Probe Number = 5, T = 20.052000 C 01:43:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:43:01 Integrated Voltage Measurement... 01:43:23 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000001412 V 01:43:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382581 Vs 01:43:24 Integrated Voltage Measurement... 01:43:46 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000002693 V 01:43:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158352163 Vs 01:44:00 Temperature Measurement, Probe Number = 0, T = 19.982000 C 01:44:00 Temperature Measurement, Probe Number = 1, T = 20.089000 C 01:44:01 Temperature Measurement, Probe Number = 2, T = 20.105000 C 01:44:01 Temperature Measurement, Probe Number = 3, T = 20.033000 C 01:44:02 Temperature Measurement, Probe Number = 4, T = 20.086000 C 01:44:03 Temperature Measurement, Probe Number = 5, T = 20.051000 C 01:44:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:44:03 Integrated Voltage Measurement... 01:44:25 Voltage Offset Correction: v_off_ini = -0.000001654 V, v_off_fin = -0.000002356 V 01:44:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158389488 Vs 01:44:25 Integrated Voltage Measurement... 01:44:47 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000001390 V 01:44:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361110 Vs 01:45:01 Temperature Measurement, Probe Number = 0, T = 19.959000 C 01:45:01 Temperature Measurement, Probe Number = 1, T = 20.088000 C 01:45:02 Temperature Measurement, Probe Number = 2, T = 20.103000 C 01:45:03 Temperature Measurement, Probe Number = 3, T = 20.033000 C 01:45:03 Temperature Measurement, Probe Number = 4, T = 20.085000 C 01:45:04 Temperature Measurement, Probe Number = 5, T = 20.051000 C 01:45:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:45:04 Integrated Voltage Measurement... 01:45:26 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000000439 V 01:45:26 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158366158 Vs 01:45:26 Integrated Voltage Measurement... 01:45:49 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000003738 V 01:45:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158351825 Vs 01:46:02 Temperature Measurement, Probe Number = 0, T = 19.939000 C 01:46:03 Temperature Measurement, Probe Number = 1, T = 20.086000 C 01:46:03 Temperature Measurement, Probe Number = 2, T = 20.104000 C 01:46:04 Temperature Measurement, Probe Number = 3, T = 20.032000 C 01:46:05 Temperature Measurement, Probe Number = 4, T = 20.085000 C 01:46:05 Temperature Measurement, Probe Number = 5, T = 20.051000 C 01:46:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:46:05 Integrated Voltage Measurement... 01:46:27 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000002136 V 01:46:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158377074 Vs 01:46:27 Integrated Voltage Measurement... 01:46:50 Voltage Offset Correction: v_off_ini = -0.000000337 V, v_off_fin = -0.000001529 V 01:46:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365593 Vs 01:47:03 Temperature Measurement, Probe Number = 0, T = 19.990000 C 01:47:04 Temperature Measurement, Probe Number = 1, T = 20.090000 C 01:47:04 Temperature Measurement, Probe Number = 2, T = 20.104000 C 01:47:05 Temperature Measurement, Probe Number = 3, T = 20.032000 C 01:47:06 Temperature Measurement, Probe Number = 4, T = 20.085000 C 01:47:06 Temperature Measurement, Probe Number = 5, T = 20.052000 C 01:47:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:47:06 Integrated Voltage Measurement... 01:47:28 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000001054 V 01:47:28 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158388701 Vs 01:47:28 Integrated Voltage Measurement... 01:47:51 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000003930 V 01:47:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158350586 Vs 01:48:04 Temperature Measurement, Probe Number = 0, T = 19.984000 C 01:48:05 Temperature Measurement, Probe Number = 1, T = 20.091000 C 01:48:06 Temperature Measurement, Probe Number = 2, T = 20.105000 C 01:48:06 Temperature Measurement, Probe Number = 3, T = 20.031000 C 01:48:07 Temperature Measurement, Probe Number = 4, T = 20.084000 C 01:48:07 Temperature Measurement, Probe Number = 5, T = 20.052000 C 01:48:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.05 01:48:07 Integrated Voltage Measurement... 01:48:30 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000001493 V 01:48:30 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158373881 Vs 01:48:30 Integrated Voltage Measurement... 01:48:52 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000001910 V 01:48:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158351826 Vs 01:49:05 Temperature Measurement, Probe Number = 0, T = 19.998000 C 01:49:06 Temperature Measurement, Probe Number = 1, T = 20.091000 C 01:49:06 Temperature Measurement, Probe Number = 2, T = 20.106000 C 01:49:07 Temperature Measurement, Probe Number = 3, T = 20.032000 C 01:49:08 Temperature Measurement, Probe Number = 4, T = 20.085000 C 01:49:08 Temperature Measurement, Probe Number = 5, T = 20.052000 C 01:49:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.09 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.03 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.05 01:49:08 Integrated Voltage Measurement... 01:49:31 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001031 V 01:49:31 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382234 Vs 01:49:31 Integrated Voltage Measurement... 01:49:53 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000003497 V 01:49:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158354763 Vs 02:46:07 Temperature Measurement, Probe Number = 0, T = 19.854000 C 02:46:07 Temperature Measurement, Probe Number = 1, T = 20.073000 C 02:46:08 Temperature Measurement, Probe Number = 2, T = 20.081000 C 02:46:08 Temperature Measurement, Probe Number = 3, T = 19.999000 C 02:46:09 Temperature Measurement, Probe Number = 4, T = 20.062000 C 02:46:10 Temperature Measurement, Probe Number = 5, T = 20.038000 C 02:46:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:46:10 Integrated Voltage Measurement... 02:46:32 Voltage Offset Correction: v_off_ini = -0.000000659 V, v_off_fin = -0.000000403 V 02:46:32 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.158398990 Vs 02:46:33 Integrated Voltage Measurement... 02:46:55 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = -0.000001734 V 02:46:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158349559 Vs 02:47:09 Temperature Measurement, Probe Number = 0, T = 19.862000 C 02:47:09 Temperature Measurement, Probe Number = 1, T = 20.070000 C 02:47:10 Temperature Measurement, Probe Number = 2, T = 20.078000 C 02:47:11 Temperature Measurement, Probe Number = 3, T = 19.997000 C 02:47:11 Temperature Measurement, Probe Number = 4, T = 20.060000 C 02:47:12 Temperature Measurement, Probe Number = 5, T = 20.037000 C 02:47:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:47:12 Integrated Voltage Measurement... 02:47:34 Voltage Offset Correction: v_off_ini = -0.000001917 V, v_off_fin = 0.000000176 V 02:47:34 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158377314 Vs 02:47:34 Integrated Voltage Measurement... 02:47:56 Voltage Offset Correction: v_off_ini = -0.000000988 V, v_off_fin = -0.000002225 V 02:47:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158351069 Vs 02:48:10 Temperature Measurement, Probe Number = 0, T = 19.852000 C 02:48:11 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:48:11 Temperature Measurement, Probe Number = 2, T = 20.081000 C 02:48:12 Temperature Measurement, Probe Number = 3, T = 19.998000 C 02:48:12 Temperature Measurement, Probe Number = 4, T = 20.061000 C 02:48:13 Temperature Measurement, Probe Number = 5, T = 20.037000 C 02:48:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:48:13 Integrated Voltage Measurement... 02:48:35 Voltage Offset Correction: v_off_ini = -0.000000717 V, v_off_fin = -0.000001449 V 02:48:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158398982 Vs 02:48:35 Integrated Voltage Measurement... 02:48:58 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000002378 V 02:48:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158349709 Vs 02:49:11 Temperature Measurement, Probe Number = 0, T = 19.808000 C 02:49:12 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:49:12 Temperature Measurement, Probe Number = 2, T = 20.082000 C 02:49:13 Temperature Measurement, Probe Number = 3, T = 19.997000 C 02:49:14 Temperature Measurement, Probe Number = 4, T = 20.060000 C 02:49:14 Temperature Measurement, Probe Number = 5, T = 20.035000 C 02:49:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.81 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:49:14 Integrated Voltage Measurement... 02:49:36 Voltage Offset Correction: v_off_ini = -0.000002107 V, v_off_fin = -0.000001698 V 02:49:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158383042 Vs 02:49:37 Integrated Voltage Measurement... 02:49:59 Voltage Offset Correction: v_off_ini = 0.000001171 V, v_off_fin = -0.000001756 V 02:49:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372729 Vs 02:50:12 Temperature Measurement, Probe Number = 0, T = 19.862000 C 02:50:13 Temperature Measurement, Probe Number = 1, T = 20.073000 C 02:50:14 Temperature Measurement, Probe Number = 2, T = 20.080000 C 02:50:14 Temperature Measurement, Probe Number = 3, T = 19.998000 C 02:50:15 Temperature Measurement, Probe Number = 4, T = 20.061000 C 02:50:15 Temperature Measurement, Probe Number = 5, T = 20.036000 C 02:50:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:50:15 Integrated Voltage Measurement... 02:50:38 Voltage Offset Correction: v_off_ini = -0.000001887 V, v_off_fin = -0.000002107 V 02:50:38 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158376903 Vs 02:50:38 Integrated Voltage Measurement... 02:51:00 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000002312 V 02:51:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158353242 Vs 02:51:14 Temperature Measurement, Probe Number = 0, T = 19.872000 C 02:51:14 Temperature Measurement, Probe Number = 1, T = 20.074000 C 02:51:15 Temperature Measurement, Probe Number = 2, T = 20.080000 C 02:51:16 Temperature Measurement, Probe Number = 3, T = 19.998000 C 02:51:16 Temperature Measurement, Probe Number = 4, T = 20.060000 C 02:51:17 Temperature Measurement, Probe Number = 5, T = 20.037000 C 02:51:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:51:17 Integrated Voltage Measurement... 02:51:39 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000000776 V 02:51:39 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382894 Vs 02:51:39 Integrated Voltage Measurement... 02:52:02 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000003103 V 02:52:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158358950 Vs 02:52:15 Temperature Measurement, Probe Number = 0, T = 19.883000 C 02:52:16 Temperature Measurement, Probe Number = 1, T = 20.071000 C 02:52:16 Temperature Measurement, Probe Number = 2, T = 20.078000 C 02:52:17 Temperature Measurement, Probe Number = 3, T = 19.997000 C 02:52:18 Temperature Measurement, Probe Number = 4, T = 20.060000 C 02:52:18 Temperature Measurement, Probe Number = 5, T = 20.035000 C 02:52:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.04 02:52:18 Integrated Voltage Measurement... 02:52:40 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000000556 V 02:52:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158383992 Vs 02:52:40 Integrated Voltage Measurement... 02:53:03 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000002517 V 02:53:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371428 Vs 02:53:16 Temperature Measurement, Probe Number = 0, T = 19.904000 C 02:53:17 Temperature Measurement, Probe Number = 1, T = 20.069000 C 02:53:17 Temperature Measurement, Probe Number = 2, T = 20.080000 C 02:53:18 Temperature Measurement, Probe Number = 3, T = 19.997000 C 02:53:19 Temperature Measurement, Probe Number = 4, T = 20.060000 C 02:53:19 Temperature Measurement, Probe Number = 5, T = 20.034000 C 02:53:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.03 02:53:19 Integrated Voltage Measurement... 02:53:41 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = 0.000000703 V 02:53:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158385904 Vs 02:53:41 Integrated Voltage Measurement... 02:54:04 Voltage Offset Correction: v_off_ini = -0.000000768 V, v_off_fin = -0.000000263 V 02:54:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365362 Vs 02:54:17 Temperature Measurement, Probe Number = 0, T = 19.862000 C 02:54:18 Temperature Measurement, Probe Number = 1, T = 20.070000 C 02:54:19 Temperature Measurement, Probe Number = 2, T = 20.078000 C 02:54:19 Temperature Measurement, Probe Number = 3, T = 19.993000 C 02:54:20 Temperature Measurement, Probe Number = 4, T = 20.057000 C 02:54:20 Temperature Measurement, Probe Number = 5, T = 20.033000 C 02:54:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.03 02:54:21 Integrated Voltage Measurement... 02:54:43 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000001266 V 02:54:43 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158387264 Vs 02:54:43 Integrated Voltage Measurement... 02:55:05 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000002429 V 02:55:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158354907 Vs 02:55:19 Temperature Measurement, Probe Number = 0, T = 19.863000 C 02:55:20 Temperature Measurement, Probe Number = 1, T = 20.067000 C 02:55:20 Temperature Measurement, Probe Number = 2, T = 20.077000 C 02:55:21 Temperature Measurement, Probe Number = 3, T = 19.994000 C 02:55:22 Temperature Measurement, Probe Number = 4, T = 20.058000 C 02:55:22 Temperature Measurement, Probe Number = 5, T = 20.034000 C 02:55:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.08 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.06 P6 = Top_Jaw, Value = 20.03 02:55:22 Integrated Voltage Measurement... 02:55:44 Voltage Offset Correction: v_off_ini = -0.000002165 V, v_off_fin = -0.000001324 V 02:55:44 Integrated Voltage Measurement Delta Gap = 0.1123409 m VT = 0.158395152 Vs 02:55:44 Integrated Voltage Measurement... 02:56:07 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000001639 V 02:56:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158348950 Vs 03:52:20 Temperature Measurement, Probe Number = 0, T = 19.950000 C 03:52:21 Temperature Measurement, Probe Number = 1, T = 20.058000 C 03:52:21 Temperature Measurement, Probe Number = 2, T = 20.059000 C 03:52:22 Temperature Measurement, Probe Number = 3, T = 19.970000 C 03:52:23 Temperature Measurement, Probe Number = 4, T = 20.036000 C 03:52:23 Temperature Measurement, Probe Number = 5, T = 20.021000 C 03:52:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:52:23 Integrated Voltage Measurement... 03:52:46 Voltage Offset Correction: v_off_ini = -0.000001332 V, v_off_fin = -0.000001698 V 03:52:46 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.158409415 Vs 03:52:46 Integrated Voltage Measurement... 03:53:09 Voltage Offset Correction: v_off_ini = -0.000000380 V, v_off_fin = -0.000001902 V 03:53:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158367514 Vs 03:53:23 Temperature Measurement, Probe Number = 0, T = 20.014000 C 03:53:23 Temperature Measurement, Probe Number = 1, T = 20.062000 C 03:53:24 Temperature Measurement, Probe Number = 2, T = 20.063000 C 03:53:24 Temperature Measurement, Probe Number = 3, T = 19.974000 C 03:53:25 Temperature Measurement, Probe Number = 4, T = 20.039000 C 03:53:26 Temperature Measurement, Probe Number = 5, T = 20.022000 C 03:53:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:53:26 Integrated Voltage Measurement... 03:53:48 Voltage Offset Correction: v_off_ini = -0.000001625 V, v_off_fin = -0.000001376 V 03:53:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158385129 Vs 03:53:49 Integrated Voltage Measurement... 03:54:11 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = -0.000002488 V 03:54:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158357670 Vs 03:54:25 Temperature Measurement, Probe Number = 0, T = 20.113000 C 03:54:25 Temperature Measurement, Probe Number = 1, T = 20.063000 C 03:54:26 Temperature Measurement, Probe Number = 2, T = 20.065000 C 03:54:27 Temperature Measurement, Probe Number = 3, T = 19.978000 C 03:54:27 Temperature Measurement, Probe Number = 4, T = 20.040000 C 03:54:28 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:54:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:54:28 Integrated Voltage Measurement... 03:54:50 Voltage Offset Correction: v_off_ini = -0.000001596 V, v_off_fin = 0.000002247 V 03:54:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158388452 Vs 03:54:50 Integrated Voltage Measurement... 03:55:13 Voltage Offset Correction: v_off_ini = -0.000002371 V, v_off_fin = -0.000002488 V 03:55:13 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158339898 Vs 03:55:26 Temperature Measurement, Probe Number = 0, T = 20.153000 C 03:55:27 Temperature Measurement, Probe Number = 1, T = 20.064000 C 03:55:27 Temperature Measurement, Probe Number = 2, T = 20.066000 C 03:55:28 Temperature Measurement, Probe Number = 3, T = 19.980000 C 03:55:29 Temperature Measurement, Probe Number = 4, T = 20.040000 C 03:55:29 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:55:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:55:29 Integrated Voltage Measurement... 03:55:51 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000944 V 03:55:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158377725 Vs 03:55:51 Integrated Voltage Measurement... 03:56:14 Voltage Offset Correction: v_off_ini = -0.000000322 V, v_off_fin = -0.000002108 V 03:56:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158355204 Vs 03:56:27 Temperature Measurement, Probe Number = 0, T = 20.155000 C 03:56:28 Temperature Measurement, Probe Number = 1, T = 20.064000 C 03:56:28 Temperature Measurement, Probe Number = 2, T = 20.067000 C 03:56:29 Temperature Measurement, Probe Number = 3, T = 19.982000 C 03:56:30 Temperature Measurement, Probe Number = 4, T = 20.041000 C 03:56:30 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:56:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:56:30 Integrated Voltage Measurement... 03:56:52 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000000637 V 03:56:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158388223 Vs 03:56:52 Integrated Voltage Measurement... 03:57:15 Voltage Offset Correction: v_off_ini = -0.000000198 V, v_off_fin = -0.000001003 V 03:57:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361392 Vs 03:57:28 Temperature Measurement, Probe Number = 0, T = 20.124000 C 03:57:29 Temperature Measurement, Probe Number = 1, T = 20.065000 C 03:57:29 Temperature Measurement, Probe Number = 2, T = 20.067000 C 03:57:30 Temperature Measurement, Probe Number = 3, T = 19.982000 C 03:57:31 Temperature Measurement, Probe Number = 4, T = 20.040000 C 03:57:31 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:57:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:57:31 Integrated Voltage Measurement... 03:57:54 Voltage Offset Correction: v_off_ini = -0.000002107 V, v_off_fin = -0.000000110 V 03:57:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158386613 Vs 03:57:54 Integrated Voltage Measurement... 03:58:16 Voltage Offset Correction: v_off_ini = -0.000000651 V, v_off_fin = -0.000002708 V 03:58:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158354898 Vs 03:58:30 Temperature Measurement, Probe Number = 0, T = 20.104000 C 03:58:30 Temperature Measurement, Probe Number = 1, T = 20.064000 C 03:58:31 Temperature Measurement, Probe Number = 2, T = 20.066000 C 03:58:32 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:58:32 Temperature Measurement, Probe Number = 4, T = 20.040000 C 03:58:33 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:58:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:58:33 Integrated Voltage Measurement... 03:58:55 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000000154 V 03:58:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158375227 Vs 03:58:55 Integrated Voltage Measurement... 03:59:17 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = -0.000002254 V 03:59:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371732 Vs 03:59:31 Temperature Measurement, Probe Number = 0, T = 20.164000 C 03:59:31 Temperature Measurement, Probe Number = 1, T = 20.064000 C 03:59:32 Temperature Measurement, Probe Number = 2, T = 20.066000 C 03:59:33 Temperature Measurement, Probe Number = 3, T = 19.982000 C 03:59:33 Temperature Measurement, Probe Number = 4, T = 20.040000 C 03:59:34 Temperature Measurement, Probe Number = 5, T = 20.023000 C 03:59:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 03:59:34 Integrated Voltage Measurement... 03:59:56 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000001281 V 03:59:56 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158390828 Vs 03:59:56 Integrated Voltage Measurement... 04:00:18 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000003117 V 04:00:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369924 Vs 04:00:32 Temperature Measurement, Probe Number = 0, T = 20.124000 C 04:00:33 Temperature Measurement, Probe Number = 1, T = 20.064000 C 04:00:33 Temperature Measurement, Probe Number = 2, T = 20.064000 C 04:00:34 Temperature Measurement, Probe Number = 3, T = 19.980000 C 04:00:35 Temperature Measurement, Probe Number = 4, T = 20.038000 C 04:00:35 Temperature Measurement, Probe Number = 5, T = 20.022000 C 04:00:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 04:00:35 Integrated Voltage Measurement... 04:00:57 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000000505 V 04:00:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158382155 Vs 04:00:57 Integrated Voltage Measurement... 04:01:20 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000001691 V 04:01:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365022 Vs 04:01:33 Temperature Measurement, Probe Number = 0, T = 20.045000 C 04:01:34 Temperature Measurement, Probe Number = 1, T = 20.063000 C 04:01:35 Temperature Measurement, Probe Number = 2, T = 20.063000 C 04:01:35 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:01:36 Temperature Measurement, Probe Number = 4, T = 20.037000 C 04:01:36 Temperature Measurement, Probe Number = 5, T = 20.022000 C 04:01:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 04:01:36 Integrated Voltage Measurement... 04:01:59 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000000337 V 04:01:59 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158375277 Vs 04:01:59 Integrated Voltage Measurement... 04:02:21 Voltage Offset Correction: v_off_ini = 0.000001332 V, v_off_fin = -0.000000563 V 04:02:21 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158383466 Vs 04:58:35 Temperature Measurement, Probe Number = 0, T = 19.604000 C 04:58:35 Temperature Measurement, Probe Number = 1, T = 20.024000 C 04:58:36 Temperature Measurement, Probe Number = 2, T = 20.017000 C 04:58:37 Temperature Measurement, Probe Number = 3, T = 19.917000 C 04:58:37 Temperature Measurement, Probe Number = 4, T = 19.997000 C 04:58:38 Temperature Measurement, Probe Number = 5, T = 19.988000 C 04:58:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 04:58:38 Integrated Voltage Measurement... 04:59:00 Voltage Offset Correction: v_off_ini = -0.000000037 V, v_off_fin = 0.000001939 V 04:59:00 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.158378003 Vs 04:59:00 Integrated Voltage Measurement... 04:59:27 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000002692 V 04:59:27 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158355968 Vs 04:59:41 Temperature Measurement, Probe Number = 0, T = 19.607000 C 04:59:42 Temperature Measurement, Probe Number = 1, T = 20.025000 C 04:59:42 Temperature Measurement, Probe Number = 2, T = 20.019000 C 04:59:43 Temperature Measurement, Probe Number = 3, T = 19.919000 C 04:59:43 Temperature Measurement, Probe Number = 4, T = 19.997000 C 04:59:44 Temperature Measurement, Probe Number = 5, T = 19.989000 C 04:59:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 04:59:44 Integrated Voltage Measurement... 05:00:06 Voltage Offset Correction: v_off_ini = -0.000000900 V, v_off_fin = -0.000000615 V 05:00:06 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158369140 Vs 05:00:06 Integrated Voltage Measurement... 05:00:28 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000001302 V 05:00:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369402 Vs 05:00:42 Temperature Measurement, Probe Number = 0, T = 19.603000 C 05:00:43 Temperature Measurement, Probe Number = 1, T = 20.022000 C 05:00:43 Temperature Measurement, Probe Number = 2, T = 20.017000 C 05:00:44 Temperature Measurement, Probe Number = 3, T = 19.918000 C 05:00:44 Temperature Measurement, Probe Number = 4, T = 19.996000 C 05:00:45 Temperature Measurement, Probe Number = 5, T = 19.989000 C 05:00:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 05:00:45 Integrated Voltage Measurement... 05:01:07 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000000834 V 05:01:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393396 Vs 05:01:07 Integrated Voltage Measurement... 05:01:30 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002172 V 05:01:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367538 Vs 05:01:43 Temperature Measurement, Probe Number = 0, T = 19.601000 C 05:01:44 Temperature Measurement, Probe Number = 1, T = 20.022000 C 05:01:44 Temperature Measurement, Probe Number = 2, T = 20.015000 C 05:01:45 Temperature Measurement, Probe Number = 3, T = 19.916000 C 05:01:46 Temperature Measurement, Probe Number = 4, T = 19.995000 C 05:01:46 Temperature Measurement, Probe Number = 5, T = 19.987000 C 05:01:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 05:01:46 Integrated Voltage Measurement... 05:02:09 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = 0.000000263 V 05:02:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392923 Vs 05:02:09 Integrated Voltage Measurement... 05:02:31 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = -0.000001565 V 05:02:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364403 Vs 05:02:45 Temperature Measurement, Probe Number = 0, T = 19.615000 C 05:02:45 Temperature Measurement, Probe Number = 1, T = 20.023000 C 05:02:46 Temperature Measurement, Probe Number = 2, T = 20.015000 C 05:02:46 Temperature Measurement, Probe Number = 3, T = 19.915000 C 05:02:47 Temperature Measurement, Probe Number = 4, T = 19.995000 C 05:02:48 Temperature Measurement, Probe Number = 5, T = 19.987000 C 05:02:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 05:02:48 Integrated Voltage Measurement... 05:03:10 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000001638 V 05:03:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158391406 Vs 05:03:10 Integrated Voltage Measurement... 05:03:32 Voltage Offset Correction: v_off_ini = -0.000000768 V, v_off_fin = -0.000001499 V 05:03:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372377 Vs 05:03:46 Temperature Measurement, Probe Number = 0, T = 19.624000 C 05:03:46 Temperature Measurement, Probe Number = 1, T = 20.018000 C 05:03:47 Temperature Measurement, Probe Number = 2, T = 20.011000 C 05:03:47 Temperature Measurement, Probe Number = 3, T = 19.914000 C 05:03:48 Temperature Measurement, Probe Number = 4, T = 19.995000 C 05:03:49 Temperature Measurement, Probe Number = 5, T = 19.986000 C 05:03:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 05:03:49 Integrated Voltage Measurement... 05:04:15 Voltage Offset Correction: v_off_ini = -0.000000534 V, v_off_fin = -0.000000549 V 05:04:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158380747 Vs 05:04:15 Integrated Voltage Measurement... 05:04:37 Voltage Offset Correction: v_off_ini = -0.000000870 V, v_off_fin = -0.000002157 V 05:04:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158364414 Vs 05:04:51 Temperature Measurement, Probe Number = 0, T = 19.618000 C 05:04:52 Temperature Measurement, Probe Number = 1, T = 20.023000 C 05:04:52 Temperature Measurement, Probe Number = 2, T = 20.016000 C 05:04:53 Temperature Measurement, Probe Number = 3, T = 19.914000 C 05:04:53 Temperature Measurement, Probe Number = 4, T = 19.993000 C 05:04:54 Temperature Measurement, Probe Number = 5, T = 19.986000 C 05:04:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.99 05:04:54 Integrated Voltage Measurement... 05:05:16 Voltage Offset Correction: v_off_ini = -0.000000731 V, v_off_fin = -0.000000080 V 05:05:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158386223 Vs 05:05:16 Integrated Voltage Measurement... 05:05:38 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000002611 V 05:05:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365894 Vs 05:05:52 Temperature Measurement, Probe Number = 0, T = 19.599000 C 05:05:53 Temperature Measurement, Probe Number = 1, T = 20.018000 C 05:05:53 Temperature Measurement, Probe Number = 2, T = 20.010000 C 05:05:54 Temperature Measurement, Probe Number = 3, T = 19.912000 C 05:05:54 Temperature Measurement, Probe Number = 4, T = 19.991000 C 05:05:55 Temperature Measurement, Probe Number = 5, T = 19.985000 C 05:05:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.98 05:05:55 Integrated Voltage Measurement... 05:06:17 Voltage Offset Correction: v_off_ini = -0.000000804 V, v_off_fin = -0.000000088 V 05:06:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158387736 Vs 05:06:17 Integrated Voltage Measurement... 05:06:39 Voltage Offset Correction: v_off_ini = -0.000000680 V, v_off_fin = -0.000002136 V 05:06:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158362798 Vs 05:06:53 Temperature Measurement, Probe Number = 0, T = 19.584000 C 05:06:54 Temperature Measurement, Probe Number = 1, T = 20.016000 C 05:06:54 Temperature Measurement, Probe Number = 2, T = 20.005000 C 05:06:55 Temperature Measurement, Probe Number = 3, T = 19.912000 C 05:06:55 Temperature Measurement, Probe Number = 4, T = 19.989000 C 05:06:56 Temperature Measurement, Probe Number = 5, T = 19.984000 C 05:06:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.98 05:06:56 Integrated Voltage Measurement... 05:07:18 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = -0.000000351 V 05:07:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158386010 Vs 05:07:19 Integrated Voltage Measurement... 05:07:41 Voltage Offset Correction: v_off_ini = -0.000001939 V, v_off_fin = -0.000002655 V 05:07:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158358599 Vs 05:07:55 Temperature Measurement, Probe Number = 0, T = 19.585000 C 05:07:56 Temperature Measurement, Probe Number = 1, T = 20.022000 C 05:07:56 Temperature Measurement, Probe Number = 2, T = 20.014000 C 05:07:57 Temperature Measurement, Probe Number = 3, T = 19.912000 C 05:07:57 Temperature Measurement, Probe Number = 4, T = 19.991000 C 05:07:58 Temperature Measurement, Probe Number = 5, T = 19.986000 C 05:07:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.99 05:07:58 Integrated Voltage Measurement... 05:08:20 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = -0.000000205 V 05:08:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158388760 Vs 05:08:20 Integrated Voltage Measurement... 05:08:42 Voltage Offset Correction: v_off_ini = 0.000000673 V, v_off_fin = -0.000001492 V 05:08:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367077 Vs 06:04:56 Temperature Measurement, Probe Number = 0, T = 19.618000 C 06:04:57 Temperature Measurement, Probe Number = 1, T = 19.996000 C 06:04:57 Temperature Measurement, Probe Number = 2, T = 19.982000 C 06:04:58 Temperature Measurement, Probe Number = 3, T = 19.881000 C 06:04:58 Temperature Measurement, Probe Number = 4, T = 19.963000 C 06:04:59 Temperature Measurement, Probe Number = 5, T = 19.963000 C 06:04:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:04:59 Integrated Voltage Measurement... 06:05:21 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000002349 V 06:05:21 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158420607 Vs 06:05:21 Integrated Voltage Measurement... 06:05:44 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000000849 V 06:05:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369160 Vs 06:05:57 Temperature Measurement, Probe Number = 0, T = 19.601000 C 06:05:58 Temperature Measurement, Probe Number = 1, T = 19.994000 C 06:05:58 Temperature Measurement, Probe Number = 2, T = 19.981000 C 06:05:59 Temperature Measurement, Probe Number = 3, T = 19.880000 C 06:06:00 Temperature Measurement, Probe Number = 4, T = 19.963000 C 06:06:00 Temperature Measurement, Probe Number = 5, T = 19.963000 C 06:06:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:06:00 Integrated Voltage Measurement... 06:06:22 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000001149 V 06:06:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158387102 Vs 06:06:22 Integrated Voltage Measurement... 06:06:45 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001888 V 06:06:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380070 Vs 06:06:58 Temperature Measurement, Probe Number = 0, T = 19.579000 C 06:06:59 Temperature Measurement, Probe Number = 1, T = 19.992000 C 06:06:59 Temperature Measurement, Probe Number = 2, T = 19.979000 C 06:07:00 Temperature Measurement, Probe Number = 3, T = 19.879000 C 06:07:01 Temperature Measurement, Probe Number = 4, T = 19.960000 C 06:07:01 Temperature Measurement, Probe Number = 5, T = 19.961000 C 06:07:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:07:01 Integrated Voltage Measurement... 06:07:23 Voltage Offset Correction: v_off_ini = -0.000002019 V, v_off_fin = -0.000000161 V 06:07:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393030 Vs 06:07:24 Integrated Voltage Measurement... 06:07:46 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002042 V 06:07:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379110 Vs 06:08:00 Temperature Measurement, Probe Number = 0, T = 19.568000 C 06:08:00 Temperature Measurement, Probe Number = 1, T = 19.991000 C 06:08:01 Temperature Measurement, Probe Number = 2, T = 19.976000 C 06:08:02 Temperature Measurement, Probe Number = 3, T = 19.878000 C 06:08:02 Temperature Measurement, Probe Number = 4, T = 19.958000 C 06:08:03 Temperature Measurement, Probe Number = 5, T = 19.960000 C 06:08:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:08:03 Integrated Voltage Measurement... 06:08:25 Voltage Offset Correction: v_off_ini = -0.000001851 V, v_off_fin = -0.000001610 V 06:08:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398322 Vs 06:08:25 Integrated Voltage Measurement... 06:08:47 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000001435 V 06:08:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369480 Vs 06:09:01 Temperature Measurement, Probe Number = 0, T = 19.555000 C 06:09:01 Temperature Measurement, Probe Number = 1, T = 19.995000 C 06:09:02 Temperature Measurement, Probe Number = 2, T = 19.981000 C 06:09:03 Temperature Measurement, Probe Number = 3, T = 19.879000 C 06:09:03 Temperature Measurement, Probe Number = 4, T = 19.959000 C 06:09:04 Temperature Measurement, Probe Number = 5, T = 19.960000 C 06:09:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.55 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:09:04 Integrated Voltage Measurement... 06:09:26 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000000337 V 06:09:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409359 Vs 06:09:26 Integrated Voltage Measurement... 06:09:49 Voltage Offset Correction: v_off_ini = -0.000000329 V, v_off_fin = -0.000001903 V 06:09:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379084 Vs 06:10:02 Temperature Measurement, Probe Number = 0, T = 19.567000 C 06:10:03 Temperature Measurement, Probe Number = 1, T = 19.998000 C 06:10:03 Temperature Measurement, Probe Number = 2, T = 19.984000 C 06:10:04 Temperature Measurement, Probe Number = 3, T = 19.877000 C 06:10:05 Temperature Measurement, Probe Number = 4, T = 19.960000 C 06:10:05 Temperature Measurement, Probe Number = 5, T = 19.960000 C 06:10:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:10:05 Integrated Voltage Measurement... 06:10:27 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000000666 V 06:10:27 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158417086 Vs 06:10:27 Integrated Voltage Measurement... 06:10:50 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = -0.000002687 V 06:10:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369446 Vs 06:11:03 Temperature Measurement, Probe Number = 0, T = 19.573000 C 06:11:04 Temperature Measurement, Probe Number = 1, T = 19.996000 C 06:11:04 Temperature Measurement, Probe Number = 2, T = 19.981000 C 06:11:05 Temperature Measurement, Probe Number = 3, T = 19.879000 C 06:11:06 Temperature Measurement, Probe Number = 4, T = 19.960000 C 06:11:06 Temperature Measurement, Probe Number = 5, T = 19.957000 C 06:11:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:11:06 Integrated Voltage Measurement... 06:11:28 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = 0.000000029 V 06:11:28 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158399708 Vs 06:11:28 Integrated Voltage Measurement... 06:11:51 Voltage Offset Correction: v_off_ini = -0.000000908 V, v_off_fin = -0.000002255 V 06:11:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370502 Vs 06:12:05 Temperature Measurement, Probe Number = 0, T = 19.585000 C 06:12:05 Temperature Measurement, Probe Number = 1, T = 19.997000 C 06:12:06 Temperature Measurement, Probe Number = 2, T = 19.982000 C 06:12:07 Temperature Measurement, Probe Number = 3, T = 19.878000 C 06:12:07 Temperature Measurement, Probe Number = 4, T = 19.960000 C 06:12:08 Temperature Measurement, Probe Number = 5, T = 19.959000 C 06:12:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:12:08 Integrated Voltage Measurement... 06:12:30 Voltage Offset Correction: v_off_ini = -0.000001193 V, v_off_fin = -0.000000717 V 06:12:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158394717 Vs 06:12:30 Integrated Voltage Measurement... 06:12:53 Voltage Offset Correction: v_off_ini = -0.000000102 V, v_off_fin = -0.000002964 V 06:12:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387427 Vs 06:13:06 Temperature Measurement, Probe Number = 0, T = 19.593000 C 06:13:07 Temperature Measurement, Probe Number = 1, T = 19.994000 C 06:13:07 Temperature Measurement, Probe Number = 2, T = 19.980000 C 06:13:08 Temperature Measurement, Probe Number = 3, T = 19.878000 C 06:13:09 Temperature Measurement, Probe Number = 4, T = 19.960000 C 06:13:09 Temperature Measurement, Probe Number = 5, T = 19.956000 C 06:13:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 06:13:09 Integrated Voltage Measurement... 06:13:31 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000001398 V 06:13:32 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158403488 Vs 06:13:32 Integrated Voltage Measurement... 06:13:54 Voltage Offset Correction: v_off_ini = -0.000000381 V, v_off_fin = -0.000002100 V 06:13:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372364 Vs 06:14:07 Temperature Measurement, Probe Number = 0, T = 19.596000 C 06:14:08 Temperature Measurement, Probe Number = 1, T = 19.994000 C 06:14:08 Temperature Measurement, Probe Number = 2, T = 19.985000 C 06:14:09 Temperature Measurement, Probe Number = 3, T = 19.878000 C 06:14:10 Temperature Measurement, Probe Number = 4, T = 19.959000 C 06:14:10 Temperature Measurement, Probe Number = 5, T = 19.955000 C 06:14:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.95 06:14:10 Integrated Voltage Measurement... 06:14:32 Voltage Offset Correction: v_off_ini = -0.000001867 V, v_off_fin = -0.000001713 V 06:14:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398034 Vs 06:14:33 Integrated Voltage Measurement... 06:14:55 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000001786 V 06:14:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388525 Vs 07:11:08 Temperature Measurement, Probe Number = 0, T = 19.552000 C 07:11:09 Temperature Measurement, Probe Number = 1, T = 19.965000 C 07:11:09 Temperature Measurement, Probe Number = 2, T = 19.948000 C 07:11:10 Temperature Measurement, Probe Number = 3, T = 19.846000 C 07:11:11 Temperature Measurement, Probe Number = 4, T = 19.928000 C 07:11:11 Temperature Measurement, Probe Number = 5, T = 19.930000 C 07:11:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.55 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:11:11 Integrated Voltage Measurement... 07:11:33 Voltage Offset Correction: v_off_ini = -0.000000432 V, v_off_fin = 0.000000454 V 07:11:33 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158419321 Vs 07:11:33 Integrated Voltage Measurement... 07:11:56 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000001727 V 07:11:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382463 Vs 07:12:09 Temperature Measurement, Probe Number = 0, T = 19.561000 C 07:12:10 Temperature Measurement, Probe Number = 1, T = 19.969000 C 07:12:10 Temperature Measurement, Probe Number = 2, T = 19.950000 C 07:12:11 Temperature Measurement, Probe Number = 3, T = 19.846000 C 07:12:12 Temperature Measurement, Probe Number = 4, T = 19.929000 C 07:12:12 Temperature Measurement, Probe Number = 5, T = 19.930000 C 07:12:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.56 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:12:12 Integrated Voltage Measurement... 07:12:34 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000000739 V 07:12:35 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158406552 Vs 07:12:35 Integrated Voltage Measurement... 07:12:57 Voltage Offset Correction: v_off_ini = -0.000002151 V, v_off_fin = -0.000002956 V 07:12:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158355163 Vs 07:13:10 Temperature Measurement, Probe Number = 0, T = 19.569000 C 07:13:11 Temperature Measurement, Probe Number = 1, T = 19.965000 C 07:13:12 Temperature Measurement, Probe Number = 2, T = 19.946000 C 07:13:12 Temperature Measurement, Probe Number = 3, T = 19.849000 C 07:13:13 Temperature Measurement, Probe Number = 4, T = 19.929000 C 07:13:13 Temperature Measurement, Probe Number = 5, T = 19.929000 C 07:13:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:13:14 Integrated Voltage Measurement... 07:13:36 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = 0.000000110 V 07:13:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398298 Vs 07:13:36 Integrated Voltage Measurement... 07:13:59 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000001640 V 07:13:59 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158390678 Vs 07:14:12 Temperature Measurement, Probe Number = 0, T = 19.569000 C 07:14:13 Temperature Measurement, Probe Number = 1, T = 19.967000 C 07:14:13 Temperature Measurement, Probe Number = 2, T = 19.950000 C 07:14:14 Temperature Measurement, Probe Number = 3, T = 19.846000 C 07:14:15 Temperature Measurement, Probe Number = 4, T = 19.929000 C 07:14:15 Temperature Measurement, Probe Number = 5, T = 19.928000 C 07:14:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:14:15 Integrated Voltage Measurement... 07:14:37 Voltage Offset Correction: v_off_ini = -0.000000578 V, v_off_fin = -0.000000380 V 07:14:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158383454 Vs 07:14:37 Integrated Voltage Measurement... 07:15:00 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000002935 V 07:15:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371369 Vs 07:15:13 Temperature Measurement, Probe Number = 0, T = 19.579000 C 07:15:14 Temperature Measurement, Probe Number = 1, T = 19.968000 C 07:15:14 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:15:15 Temperature Measurement, Probe Number = 3, T = 19.845000 C 07:15:16 Temperature Measurement, Probe Number = 4, T = 19.928000 C 07:15:16 Temperature Measurement, Probe Number = 5, T = 19.929000 C 07:15:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:15:16 Integrated Voltage Measurement... 07:15:38 Voltage Offset Correction: v_off_ini = -0.000000834 V, v_off_fin = 0.000000293 V 07:15:38 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158413649 Vs 07:15:38 Integrated Voltage Measurement... 07:16:01 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000003762 V 07:16:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376127 Vs 07:16:15 Temperature Measurement, Probe Number = 0, T = 19.581000 C 07:16:15 Temperature Measurement, Probe Number = 1, T = 19.966000 C 07:16:16 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:16:16 Temperature Measurement, Probe Number = 3, T = 19.847000 C 07:16:17 Temperature Measurement, Probe Number = 4, T = 19.926000 C 07:16:18 Temperature Measurement, Probe Number = 5, T = 19.929000 C 07:16:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:16:18 Integrated Voltage Measurement... 07:16:40 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = 0.000000446 V 07:16:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158401818 Vs 07:16:40 Integrated Voltage Measurement... 07:17:02 Voltage Offset Correction: v_off_ini = -0.000000966 V, v_off_fin = -0.000003133 V 07:17:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371980 Vs 07:17:16 Temperature Measurement, Probe Number = 0, T = 19.593000 C 07:17:16 Temperature Measurement, Probe Number = 1, T = 19.969000 C 07:17:17 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:17:17 Temperature Measurement, Probe Number = 3, T = 19.848000 C 07:17:18 Temperature Measurement, Probe Number = 4, T = 19.928000 C 07:17:19 Temperature Measurement, Probe Number = 5, T = 19.929000 C 07:17:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:17:19 Integrated Voltage Measurement... 07:17:41 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000001851 V 07:17:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158413139 Vs 07:17:41 Integrated Voltage Measurement... 07:18:03 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000001347 V 07:18:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379566 Vs 07:18:17 Temperature Measurement, Probe Number = 0, T = 19.589000 C 07:18:17 Temperature Measurement, Probe Number = 1, T = 19.965000 C 07:18:18 Temperature Measurement, Probe Number = 2, T = 19.949000 C 07:18:19 Temperature Measurement, Probe Number = 3, T = 19.847000 C 07:18:19 Temperature Measurement, Probe Number = 4, T = 19.927000 C 07:18:20 Temperature Measurement, Probe Number = 5, T = 19.929000 C 07:18:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:18:20 Integrated Voltage Measurement... 07:18:42 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000001259 V 07:18:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415014 Vs 07:18:42 Integrated Voltage Measurement... 07:19:04 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = -0.000001610 V 07:19:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379917 Vs 07:19:18 Temperature Measurement, Probe Number = 0, T = 19.576000 C 07:19:19 Temperature Measurement, Probe Number = 1, T = 19.959000 C 07:19:19 Temperature Measurement, Probe Number = 2, T = 19.942000 C 07:19:20 Temperature Measurement, Probe Number = 3, T = 19.845000 C 07:19:20 Temperature Measurement, Probe Number = 4, T = 19.924000 C 07:19:21 Temperature Measurement, Probe Number = 5, T = 19.927000 C 07:19:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 07:19:21 Integrated Voltage Measurement... 07:19:43 Voltage Offset Correction: v_off_ini = -0.000000959 V, v_off_fin = -0.000000446 V 07:19:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158401233 Vs 07:19:43 Integrated Voltage Measurement... 07:20:05 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = -0.000001683 V 07:20:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382556 Vs 07:20:19 Temperature Measurement, Probe Number = 0, T = 19.582000 C 07:20:20 Temperature Measurement, Probe Number = 1, T = 19.964000 C 07:20:20 Temperature Measurement, Probe Number = 2, T = 19.950000 C 07:20:21 Temperature Measurement, Probe Number = 3, T = 19.848000 C 07:20:21 Temperature Measurement, Probe Number = 4, T = 19.926000 C 07:20:22 Temperature Measurement, Probe Number = 5, T = 19.926000 C 07:20:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.93 07:20:22 Integrated Voltage Measurement... 07:20:44 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000001654 V 07:20:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409980 Vs 07:20:44 Integrated Voltage Measurement... 07:21:06 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = -0.000003249 V 07:21:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376854 Vs 08:17:20 Temperature Measurement, Probe Number = 0, T = 19.574000 C 08:17:21 Temperature Measurement, Probe Number = 1, T = 19.937000 C 08:17:21 Temperature Measurement, Probe Number = 2, T = 19.919000 C 08:17:22 Temperature Measurement, Probe Number = 3, T = 19.823000 C 08:17:22 Temperature Measurement, Probe Number = 4, T = 19.901000 C 08:17:23 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:17:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:17:23 Integrated Voltage Measurement... 08:17:45 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000001712 V 08:17:45 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158444311 Vs 08:17:45 Integrated Voltage Measurement... 08:18:07 Voltage Offset Correction: v_off_ini = 0.000000315 V, v_off_fin = -0.000002575 V 08:18:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386104 Vs 08:18:21 Temperature Measurement, Probe Number = 0, T = 19.581000 C 08:18:22 Temperature Measurement, Probe Number = 1, T = 19.940000 C 08:18:22 Temperature Measurement, Probe Number = 2, T = 19.923000 C 08:18:23 Temperature Measurement, Probe Number = 3, T = 19.825000 C 08:18:23 Temperature Measurement, Probe Number = 4, T = 19.902000 C 08:18:24 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:18:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:18:24 Integrated Voltage Measurement... 08:18:46 Voltage Offset Correction: v_off_ini = -0.000000563 V, v_off_fin = 0.000000497 V 08:18:46 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158408677 Vs 08:18:46 Integrated Voltage Measurement... 08:19:09 Voltage Offset Correction: v_off_ini = -0.000001265 V, v_off_fin = -0.000003840 V 08:19:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385007 Vs 08:19:22 Temperature Measurement, Probe Number = 0, T = 19.583000 C 08:19:23 Temperature Measurement, Probe Number = 1, T = 19.942000 C 08:19:23 Temperature Measurement, Probe Number = 2, T = 19.926000 C 08:19:24 Temperature Measurement, Probe Number = 3, T = 19.823000 C 08:19:25 Temperature Measurement, Probe Number = 4, T = 19.900000 C 08:19:25 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:19:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:19:25 Integrated Voltage Measurement... 08:19:48 Voltage Offset Correction: v_off_ini = -0.000001382 V, v_off_fin = -0.000001331 V 08:19:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158416195 Vs 08:19:49 Integrated Voltage Measurement... 08:20:11 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000002574 V 08:20:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380645 Vs 08:20:25 Temperature Measurement, Probe Number = 0, T = 19.590000 C 08:20:26 Temperature Measurement, Probe Number = 1, T = 19.943000 C 08:20:26 Temperature Measurement, Probe Number = 2, T = 19.927000 C 08:20:27 Temperature Measurement, Probe Number = 3, T = 19.822000 C 08:20:28 Temperature Measurement, Probe Number = 4, T = 19.900000 C 08:20:28 Temperature Measurement, Probe Number = 5, T = 19.904000 C 08:20:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:20:28 Integrated Voltage Measurement... 08:20:50 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000000578 V 08:20:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158424169 Vs 08:20:50 Integrated Voltage Measurement... 08:21:13 Voltage Offset Correction: v_off_ini = -0.000002589 V, v_off_fin = -0.000001843 V 08:21:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158365195 Vs 08:21:26 Temperature Measurement, Probe Number = 0, T = 19.591000 C 08:21:27 Temperature Measurement, Probe Number = 1, T = 19.942000 C 08:21:27 Temperature Measurement, Probe Number = 2, T = 19.925000 C 08:21:28 Temperature Measurement, Probe Number = 3, T = 19.823000 C 08:21:29 Temperature Measurement, Probe Number = 4, T = 19.899000 C 08:21:29 Temperature Measurement, Probe Number = 5, T = 19.904000 C 08:21:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:21:29 Integrated Voltage Measurement... 08:21:51 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000000614 V 08:21:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158422381 Vs 08:21:52 Integrated Voltage Measurement... 08:22:14 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002267 V 08:22:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393443 Vs 08:22:28 Temperature Measurement, Probe Number = 0, T = 19.594000 C 08:22:28 Temperature Measurement, Probe Number = 1, T = 19.944000 C 08:22:29 Temperature Measurement, Probe Number = 2, T = 19.927000 C 08:22:30 Temperature Measurement, Probe Number = 3, T = 19.824000 C 08:22:30 Temperature Measurement, Probe Number = 4, T = 19.900000 C 08:22:31 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:22:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:22:31 Integrated Voltage Measurement... 08:22:53 Voltage Offset Correction: v_off_ini = -0.000001850 V, v_off_fin = -0.000001346 V 08:22:53 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158427011 Vs 08:22:53 Integrated Voltage Measurement... 08:23:15 Voltage Offset Correction: v_off_ini = -0.000000271 V, v_off_fin = -0.000002581 V 08:23:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392034 Vs 08:23:29 Temperature Measurement, Probe Number = 0, T = 19.608000 C 08:23:30 Temperature Measurement, Probe Number = 1, T = 19.944000 C 08:23:30 Temperature Measurement, Probe Number = 2, T = 19.926000 C 08:23:31 Temperature Measurement, Probe Number = 3, T = 19.823000 C 08:23:32 Temperature Measurement, Probe Number = 4, T = 19.900000 C 08:23:32 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:23:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:23:32 Integrated Voltage Measurement... 08:23:54 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000000234 V 08:23:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158430011 Vs 08:23:54 Integrated Voltage Measurement... 08:24:16 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000002530 V 08:24:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387756 Vs 08:24:30 Temperature Measurement, Probe Number = 0, T = 19.613000 C 08:24:31 Temperature Measurement, Probe Number = 1, T = 19.944000 C 08:24:31 Temperature Measurement, Probe Number = 2, T = 19.926000 C 08:24:32 Temperature Measurement, Probe Number = 3, T = 19.824000 C 08:24:32 Temperature Measurement, Probe Number = 4, T = 19.900000 C 08:24:33 Temperature Measurement, Probe Number = 5, T = 19.903000 C 08:24:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:24:33 Integrated Voltage Measurement... 08:24:55 Voltage Offset Correction: v_off_ini = -0.000000037 V, v_off_fin = -0.000001770 V 08:24:55 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158414058 Vs 08:24:55 Integrated Voltage Measurement... 08:25:18 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002779 V 08:25:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378155 Vs 08:25:31 Temperature Measurement, Probe Number = 0, T = 19.615000 C 08:25:32 Temperature Measurement, Probe Number = 1, T = 19.941000 C 08:25:32 Temperature Measurement, Probe Number = 2, T = 19.923000 C 08:25:33 Temperature Measurement, Probe Number = 3, T = 19.825000 C 08:25:34 Temperature Measurement, Probe Number = 4, T = 19.899000 C 08:25:34 Temperature Measurement, Probe Number = 5, T = 19.902000 C 08:25:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:25:34 Integrated Voltage Measurement... 08:25:56 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = 0.000000212 V 08:25:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400120 Vs 08:25:56 Integrated Voltage Measurement... 08:26:19 Voltage Offset Correction: v_off_ini = -0.000000863 V, v_off_fin = -0.000002765 V 08:26:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381681 Vs 08:26:32 Temperature Measurement, Probe Number = 0, T = 19.598000 C 08:26:33 Temperature Measurement, Probe Number = 1, T = 19.936000 C 08:26:33 Temperature Measurement, Probe Number = 2, T = 19.918000 C 08:26:34 Temperature Measurement, Probe Number = 3, T = 19.824000 C 08:26:35 Temperature Measurement, Probe Number = 4, T = 19.898000 C 08:26:35 Temperature Measurement, Probe Number = 5, T = 19.899000 C 08:26:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.90 08:26:35 Integrated Voltage Measurement... 08:26:57 Voltage Offset Correction: v_off_ini = -0.000000344 V, v_off_fin = 0.000000212 V 08:26:57 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158421672 Vs 08:26:57 Integrated Voltage Measurement... 08:27:20 Voltage Offset Correction: v_off_ini = -0.000001624 V, v_off_fin = -0.000002816 V 08:27:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381867 Vs 09:23:33 Temperature Measurement, Probe Number = 0, T = 19.575000 C 09:23:34 Temperature Measurement, Probe Number = 1, T = 19.915000 C 09:23:34 Temperature Measurement, Probe Number = 2, T = 19.895000 C 09:23:35 Temperature Measurement, Probe Number = 3, T = 19.803000 C 09:23:36 Temperature Measurement, Probe Number = 4, T = 19.876000 C 09:23:36 Temperature Measurement, Probe Number = 5, T = 19.882000 C 09:23:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:23:36 Integrated Voltage Measurement... 09:23:58 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = 0.000000256 V 09:23:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158437494 Vs 09:23:58 Integrated Voltage Measurement... 09:24:21 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000001968 V 09:24:21 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158390925 Vs 09:24:34 Temperature Measurement, Probe Number = 0, T = 19.587000 C 09:24:35 Temperature Measurement, Probe Number = 1, T = 19.918000 C 09:24:35 Temperature Measurement, Probe Number = 2, T = 19.899000 C 09:24:36 Temperature Measurement, Probe Number = 3, T = 19.801000 C 09:24:37 Temperature Measurement, Probe Number = 4, T = 19.878000 C 09:24:37 Temperature Measurement, Probe Number = 5, T = 19.883000 C 09:24:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:24:37 Integrated Voltage Measurement... 09:25:00 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = 0.000000395 V 09:25:00 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158405296 Vs 09:25:00 Integrated Voltage Measurement... 09:25:23 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000002429 V 09:25:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385650 Vs 09:25:36 Temperature Measurement, Probe Number = 0, T = 19.584000 C 09:25:37 Temperature Measurement, Probe Number = 1, T = 19.913000 C 09:25:38 Temperature Measurement, Probe Number = 2, T = 19.896000 C 09:25:38 Temperature Measurement, Probe Number = 3, T = 19.802000 C 09:25:39 Temperature Measurement, Probe Number = 4, T = 19.876000 C 09:25:39 Temperature Measurement, Probe Number = 5, T = 19.882000 C 09:25:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:25:39 Integrated Voltage Measurement... 09:26:02 Voltage Offset Correction: v_off_ini = -0.000001596 V, v_off_fin = 0.000000644 V 09:26:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402056 Vs 09:26:02 Integrated Voltage Measurement... 09:26:24 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000003182 V 09:26:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403528 Vs 09:26:38 Temperature Measurement, Probe Number = 0, T = 19.598000 C 09:26:38 Temperature Measurement, Probe Number = 1, T = 19.921000 C 09:26:39 Temperature Measurement, Probe Number = 2, T = 19.901000 C 09:26:39 Temperature Measurement, Probe Number = 3, T = 19.803000 C 09:26:40 Temperature Measurement, Probe Number = 4, T = 19.877000 C 09:26:41 Temperature Measurement, Probe Number = 5, T = 19.883000 C 09:26:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:26:41 Integrated Voltage Measurement... 09:27:13 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = 0.013445552 V 09:27:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = -0.010626867 Vs 09:27:13 Integrated Voltage Measurement... 09:27:35 Voltage Offset Correction: v_off_ini = 0.000001566 V, v_off_fin = -0.000001844 V 09:27:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415906 Vs 09:27:49 Temperature Measurement, Probe Number = 0, T = 19.608000 C 09:27:49 Temperature Measurement, Probe Number = 1, T = 19.923000 C 09:27:50 Temperature Measurement, Probe Number = 2, T = 19.902000 C 09:27:51 Temperature Measurement, Probe Number = 3, T = 19.804000 C 09:27:51 Temperature Measurement, Probe Number = 4, T = 19.879000 C 09:27:52 Temperature Measurement, Probe Number = 5, T = 19.883000 C 09:27:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:27:52 Integrated Voltage Measurement... 09:28:14 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000798 V 09:28:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158419328 Vs 09:28:14 Integrated Voltage Measurement... 09:28:36 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000003102 V 09:28:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383727 Vs 09:28:50 Temperature Measurement, Probe Number = 0, T = 19.617000 C 09:28:50 Temperature Measurement, Probe Number = 1, T = 19.926000 C 09:28:51 Temperature Measurement, Probe Number = 2, T = 19.904000 C 09:28:52 Temperature Measurement, Probe Number = 3, T = 19.804000 C 09:28:52 Temperature Measurement, Probe Number = 4, T = 19.877000 C 09:28:53 Temperature Measurement, Probe Number = 5, T = 19.885000 C 09:28:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 09:28:53 Integrated Voltage Measurement... 09:29:15 Voltage Offset Correction: v_off_ini = -0.000000937 V, v_off_fin = -0.000000805 V 09:29:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420835 Vs 09:29:15 Integrated Voltage Measurement... 09:29:37 Voltage Offset Correction: v_off_ini = -0.000000051 V, v_off_fin = -0.000000373 V 09:29:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401359 Vs 09:29:51 Temperature Measurement, Probe Number = 0, T = 19.618000 C 09:29:52 Temperature Measurement, Probe Number = 1, T = 19.925000 C 09:29:52 Temperature Measurement, Probe Number = 2, T = 19.902000 C 09:29:53 Temperature Measurement, Probe Number = 3, T = 19.802000 C 09:29:53 Temperature Measurement, Probe Number = 4, T = 19.877000 C 09:29:54 Temperature Measurement, Probe Number = 5, T = 19.884000 C 09:29:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:29:54 Integrated Voltage Measurement... 09:30:16 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000001507 V 09:30:17 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409321 Vs 09:30:17 Integrated Voltage Measurement... 09:30:39 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000003213 V 09:30:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394167 Vs 09:30:53 Temperature Measurement, Probe Number = 0, T = 19.636000 C 09:30:53 Temperature Measurement, Probe Number = 1, T = 19.923000 C 09:30:54 Temperature Measurement, Probe Number = 2, T = 19.903000 C 09:30:55 Temperature Measurement, Probe Number = 3, T = 19.802000 C 09:30:55 Temperature Measurement, Probe Number = 4, T = 19.877000 C 09:30:56 Temperature Measurement, Probe Number = 5, T = 19.884000 C 09:30:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:30:56 Integrated Voltage Measurement... 09:31:18 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000001617 V 09:31:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420713 Vs 09:31:18 Integrated Voltage Measurement... 09:31:40 Voltage Offset Correction: v_off_ini = -0.000000578 V, v_off_fin = -0.000002554 V 09:31:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386756 Vs 09:31:54 Temperature Measurement, Probe Number = 0, T = 19.621000 C 09:31:55 Temperature Measurement, Probe Number = 1, T = 19.920000 C 09:31:55 Temperature Measurement, Probe Number = 2, T = 19.899000 C 09:31:56 Temperature Measurement, Probe Number = 3, T = 19.802000 C 09:31:56 Temperature Measurement, Probe Number = 4, T = 19.875000 C 09:31:57 Temperature Measurement, Probe Number = 5, T = 19.882000 C 09:31:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:31:57 Integrated Voltage Measurement... 09:32:19 Voltage Offset Correction: v_off_ini = -0.000001998 V, v_off_fin = -0.000001595 V 09:32:19 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420771 Vs 09:32:19 Integrated Voltage Measurement... 09:32:42 Voltage Offset Correction: v_off_ini = -0.000001515 V, v_off_fin = -0.000002547 V 09:32:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378870 Vs 09:32:56 Temperature Measurement, Probe Number = 0, T = 19.615000 C 09:32:56 Temperature Measurement, Probe Number = 1, T = 19.922000 C 09:32:57 Temperature Measurement, Probe Number = 2, T = 19.899000 C 09:32:57 Temperature Measurement, Probe Number = 3, T = 19.800000 C 09:32:58 Temperature Measurement, Probe Number = 4, T = 19.875000 C 09:32:59 Temperature Measurement, Probe Number = 5, T = 19.883000 C 09:32:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 09:32:59 Integrated Voltage Measurement... 09:33:21 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = 0.000000022 V 09:33:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408717 Vs 09:33:21 Integrated Voltage Measurement... 09:33:44 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000002904 V 09:33:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385996 Vs 10:29:57 Temperature Measurement, Probe Number = 0, T = 19.774000 C 10:29:58 Temperature Measurement, Probe Number = 1, T = 19.910000 C 10:29:59 Temperature Measurement, Probe Number = 2, T = 19.888000 C 10:29:59 Temperature Measurement, Probe Number = 3, T = 19.797000 C 10:30:00 Temperature Measurement, Probe Number = 4, T = 19.863000 C 10:30:00 Temperature Measurement, Probe Number = 5, T = 19.871000 C 10:30:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:30:00 Integrated Voltage Measurement... 10:30:23 Voltage Offset Correction: v_off_ini = -0.000000410 V, v_off_fin = -0.000000637 V 10:30:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158458457 Vs 10:30:23 Integrated Voltage Measurement... 10:30:45 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000001946 V 10:30:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400587 Vs 10:30:58 Temperature Measurement, Probe Number = 0, T = 19.762000 C 10:30:59 Temperature Measurement, Probe Number = 1, T = 19.910000 C 10:31:00 Temperature Measurement, Probe Number = 2, T = 19.887000 C 10:31:00 Temperature Measurement, Probe Number = 3, T = 19.796000 C 10:31:01 Temperature Measurement, Probe Number = 4, T = 19.862000 C 10:31:01 Temperature Measurement, Probe Number = 5, T = 19.869000 C 10:31:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:31:01 Integrated Voltage Measurement... 10:31:24 Voltage Offset Correction: v_off_ini = -0.000001712 V, v_off_fin = -0.000000658 V 10:31:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422506 Vs 10:31:24 Integrated Voltage Measurement... 10:31:46 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000002055 V 10:31:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390542 Vs 10:31:59 Temperature Measurement, Probe Number = 0, T = 19.756000 C 10:32:00 Temperature Measurement, Probe Number = 1, T = 19.909000 C 10:32:01 Temperature Measurement, Probe Number = 2, T = 19.889000 C 10:32:01 Temperature Measurement, Probe Number = 3, T = 19.796000 C 10:32:02 Temperature Measurement, Probe Number = 4, T = 19.862000 C 10:32:02 Temperature Measurement, Probe Number = 5, T = 19.870000 C 10:32:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:32:02 Integrated Voltage Measurement... 10:32:25 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001609 V 10:32:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158429156 Vs 10:32:25 Integrated Voltage Measurement... 10:32:47 Voltage Offset Correction: v_off_ini = -0.000002384 V, v_off_fin = -0.000001331 V 10:32:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403944 Vs 10:33:00 Temperature Measurement, Probe Number = 0, T = 19.799000 C 10:33:01 Temperature Measurement, Probe Number = 1, T = 19.914000 C 10:33:02 Temperature Measurement, Probe Number = 2, T = 19.889000 C 10:33:02 Temperature Measurement, Probe Number = 3, T = 19.799000 C 10:33:03 Temperature Measurement, Probe Number = 4, T = 19.862000 C 10:33:03 Temperature Measurement, Probe Number = 5, T = 19.871000 C 10:33:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.80 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:33:03 Integrated Voltage Measurement... 10:33:26 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = 0.000000234 V 10:33:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414679 Vs 10:33:26 Integrated Voltage Measurement... 10:33:48 Voltage Offset Correction: v_off_ini = 0.000000439 V, v_off_fin = -0.000002195 V 10:33:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419587 Vs 10:34:02 Temperature Measurement, Probe Number = 0, T = 19.817000 C 10:34:02 Temperature Measurement, Probe Number = 1, T = 19.915000 C 10:34:03 Temperature Measurement, Probe Number = 2, T = 19.887000 C 10:34:04 Temperature Measurement, Probe Number = 3, T = 19.799000 C 10:34:04 Temperature Measurement, Probe Number = 4, T = 19.863000 C 10:34:05 Temperature Measurement, Probe Number = 5, T = 19.871000 C 10:34:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:34:05 Integrated Voltage Measurement... 10:34:27 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000000256 V 10:34:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418928 Vs 10:34:28 Integrated Voltage Measurement... 10:34:50 Voltage Offset Correction: v_off_ini = 0.000000168 V, v_off_fin = -0.000001236 V 10:34:50 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158400307 Vs 10:35:03 Temperature Measurement, Probe Number = 0, T = 19.789000 C 10:35:04 Temperature Measurement, Probe Number = 1, T = 19.912000 C 10:35:05 Temperature Measurement, Probe Number = 2, T = 19.888000 C 10:35:05 Temperature Measurement, Probe Number = 3, T = 19.800000 C 10:35:06 Temperature Measurement, Probe Number = 4, T = 19.863000 C 10:35:06 Temperature Measurement, Probe Number = 5, T = 19.871000 C 10:35:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.79 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:35:06 Integrated Voltage Measurement... 10:35:29 Voltage Offset Correction: v_off_ini = -0.000001778 V, v_off_fin = -0.000001602 V 10:35:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415178 Vs 10:35:29 Integrated Voltage Measurement... 10:35:51 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000003278 V 10:35:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390332 Vs 10:36:04 Temperature Measurement, Probe Number = 0, T = 19.767000 C 10:36:05 Temperature Measurement, Probe Number = 1, T = 19.908000 C 10:36:05 Temperature Measurement, Probe Number = 2, T = 19.888000 C 10:36:06 Temperature Measurement, Probe Number = 3, T = 19.799000 C 10:36:07 Temperature Measurement, Probe Number = 4, T = 19.861000 C 10:36:07 Temperature Measurement, Probe Number = 5, T = 19.868000 C 10:36:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:36:07 Integrated Voltage Measurement... 10:36:30 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000000000 V 10:36:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421016 Vs 10:36:30 Integrated Voltage Measurement... 10:36:52 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000003651 V 10:36:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393479 Vs 10:37:07 Temperature Measurement, Probe Number = 0, T = 19.743000 C 10:37:07 Temperature Measurement, Probe Number = 1, T = 19.905000 C 10:37:08 Temperature Measurement, Probe Number = 2, T = 19.886000 C 10:37:08 Temperature Measurement, Probe Number = 3, T = 19.797000 C 10:37:09 Temperature Measurement, Probe Number = 4, T = 19.861000 C 10:37:10 Temperature Measurement, Probe Number = 5, T = 19.867000 C 10:37:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:37:10 Integrated Voltage Measurement... 10:37:32 Voltage Offset Correction: v_off_ini = -0.000002384 V, v_off_fin = -0.000002165 V 10:37:32 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158430653 Vs 10:37:32 Integrated Voltage Measurement... 10:37:54 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000001909 V 10:37:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384441 Vs 10:38:08 Temperature Measurement, Probe Number = 0, T = 19.725000 C 10:38:09 Temperature Measurement, Probe Number = 1, T = 19.906000 C 10:38:09 Temperature Measurement, Probe Number = 2, T = 19.888000 C 10:38:10 Temperature Measurement, Probe Number = 3, T = 19.797000 C 10:38:10 Temperature Measurement, Probe Number = 4, T = 19.860000 C 10:38:11 Temperature Measurement, Probe Number = 5, T = 19.868000 C 10:38:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.73 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:38:11 Integrated Voltage Measurement... 10:38:33 Voltage Offset Correction: v_off_ini = -0.000001039 V, v_off_fin = -0.000002596 V 10:38:33 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158443382 Vs 10:38:33 Integrated Voltage Measurement... 10:38:57 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000001295 V 10:38:57 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158387957 Vs 10:39:11 Temperature Measurement, Probe Number = 0, T = 19.714000 C 10:39:12 Temperature Measurement, Probe Number = 1, T = 19.904000 C 10:39:12 Temperature Measurement, Probe Number = 2, T = 19.884000 C 10:39:13 Temperature Measurement, Probe Number = 3, T = 19.798000 C 10:39:13 Temperature Measurement, Probe Number = 4, T = 19.861000 C 10:39:14 Temperature Measurement, Probe Number = 5, T = 19.867000 C 10:39:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.71 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 10:39:14 Integrated Voltage Measurement... 10:39:36 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000000848 V 10:39:36 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158420660 Vs 10:39:36 Integrated Voltage Measurement... 10:39:59 Voltage Offset Correction: v_off_ini = -0.000001411 V, v_off_fin = -0.000001960 V 10:39:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401261 Vs 11:36:12 Temperature Measurement, Probe Number = 0, T = 19.841000 C 11:36:13 Temperature Measurement, Probe Number = 1, T = 19.914000 C 11:36:13 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:36:14 Temperature Measurement, Probe Number = 3, T = 19.815000 C 11:36:15 Temperature Measurement, Probe Number = 4, T = 19.859000 C 11:36:15 Temperature Measurement, Probe Number = 5, T = 19.871000 C 11:36:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:36:15 Integrated Voltage Measurement... 11:36:37 Voltage Offset Correction: v_off_ini = -0.000000271 V, v_off_fin = -0.000001316 V 11:36:38 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158472847 Vs 11:36:38 Integrated Voltage Measurement... 11:37:00 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000001536 V 11:37:00 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158398860 Vs 11:37:14 Temperature Measurement, Probe Number = 0, T = 19.843000 C 11:37:14 Temperature Measurement, Probe Number = 1, T = 19.915000 C 11:37:15 Temperature Measurement, Probe Number = 2, T = 19.889000 C 11:37:16 Temperature Measurement, Probe Number = 3, T = 19.815000 C 11:37:16 Temperature Measurement, Probe Number = 4, T = 19.860000 C 11:37:17 Temperature Measurement, Probe Number = 5, T = 19.871000 C 11:37:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:37:17 Integrated Voltage Measurement... 11:37:39 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = 0.000000029 V 11:37:39 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158422702 Vs 11:37:39 Integrated Voltage Measurement... 11:38:02 Voltage Offset Correction: v_off_ini = 0.000000307 V, v_off_fin = -0.000002487 V 11:38:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422924 Vs 11:38:15 Temperature Measurement, Probe Number = 0, T = 19.867000 C 11:38:16 Temperature Measurement, Probe Number = 1, T = 19.916000 C 11:38:16 Temperature Measurement, Probe Number = 2, T = 19.889000 C 11:38:17 Temperature Measurement, Probe Number = 3, T = 19.816000 C 11:38:18 Temperature Measurement, Probe Number = 4, T = 19.861000 C 11:38:18 Temperature Measurement, Probe Number = 5, T = 19.872000 C 11:38:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:38:18 Integrated Voltage Measurement... 11:38:41 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = 0.000000373 V 11:38:42 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420690 Vs 11:38:42 Integrated Voltage Measurement... 11:39:04 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000002912 V 11:39:04 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158406010 Vs 11:39:18 Temperature Measurement, Probe Number = 0, T = 19.897000 C 11:39:18 Temperature Measurement, Probe Number = 1, T = 19.913000 C 11:39:19 Temperature Measurement, Probe Number = 2, T = 19.885000 C 11:39:20 Temperature Measurement, Probe Number = 3, T = 19.817000 C 11:39:20 Temperature Measurement, Probe Number = 4, T = 19.861000 C 11:39:21 Temperature Measurement, Probe Number = 5, T = 19.871000 C 11:39:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:39:21 Integrated Voltage Measurement... 11:39:43 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = 0.000001339 V 11:39:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408448 Vs 11:39:43 Integrated Voltage Measurement... 11:40:05 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000002699 V 11:40:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158408815 Vs 11:40:19 Temperature Measurement, Probe Number = 0, T = 19.909000 C 11:40:19 Temperature Measurement, Probe Number = 1, T = 19.915000 C 11:40:20 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:40:21 Temperature Measurement, Probe Number = 3, T = 19.817000 C 11:40:21 Temperature Measurement, Probe Number = 4, T = 19.860000 C 11:40:22 Temperature Measurement, Probe Number = 5, T = 19.871000 C 11:40:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:40:22 Integrated Voltage Measurement... 11:40:44 Voltage Offset Correction: v_off_ini = -0.000001119 V, v_off_fin = 0.000000234 V 11:40:44 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158423078 Vs 11:40:44 Integrated Voltage Measurement... 11:41:06 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000003518 V 11:41:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396343 Vs 11:41:20 Temperature Measurement, Probe Number = 0, T = 19.904000 C 11:41:21 Temperature Measurement, Probe Number = 1, T = 19.916000 C 11:41:21 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:41:22 Temperature Measurement, Probe Number = 3, T = 19.817000 C 11:41:23 Temperature Measurement, Probe Number = 4, T = 19.861000 C 11:41:23 Temperature Measurement, Probe Number = 5, T = 19.871000 C 11:41:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:41:23 Integrated Voltage Measurement... 11:41:45 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002165 V 11:41:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158440020 Vs 11:41:45 Integrated Voltage Measurement... 11:42:07 Voltage Offset Correction: v_off_ini = -0.000000958 V, v_off_fin = -0.000001982 V 11:42:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393450 Vs 11:42:21 Temperature Measurement, Probe Number = 0, T = 19.937000 C 11:42:22 Temperature Measurement, Probe Number = 1, T = 19.915000 C 11:42:22 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:42:23 Temperature Measurement, Probe Number = 3, T = 19.818000 C 11:42:23 Temperature Measurement, Probe Number = 4, T = 19.861000 C 11:42:24 Temperature Measurement, Probe Number = 5, T = 19.872000 C 11:42:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:42:24 Integrated Voltage Measurement... 11:42:46 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000001317 V 11:42:46 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158442173 Vs 11:42:46 Integrated Voltage Measurement... 11:43:09 Voltage Offset Correction: v_off_ini = -0.000000709 V, v_off_fin = -0.000002874 V 11:43:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158392678 Vs 11:43:22 Temperature Measurement, Probe Number = 0, T = 19.920000 C 11:43:23 Temperature Measurement, Probe Number = 1, T = 19.917000 C 11:43:24 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:43:24 Temperature Measurement, Probe Number = 3, T = 19.819000 C 11:43:25 Temperature Measurement, Probe Number = 4, T = 19.860000 C 11:43:25 Temperature Measurement, Probe Number = 5, T = 19.873000 C 11:43:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:43:26 Integrated Voltage Measurement... 11:43:48 Voltage Offset Correction: v_off_ini = -0.000000848 V, v_off_fin = 0.000001770 V 11:43:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158406483 Vs 11:43:48 Integrated Voltage Measurement... 11:44:10 Voltage Offset Correction: v_off_ini = -0.000002348 V, v_off_fin = -0.000002019 V 11:44:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393885 Vs 11:44:24 Temperature Measurement, Probe Number = 0, T = 19.901000 C 11:44:25 Temperature Measurement, Probe Number = 1, T = 19.915000 C 11:44:25 Temperature Measurement, Probe Number = 2, T = 19.888000 C 11:44:26 Temperature Measurement, Probe Number = 3, T = 19.820000 C 11:44:26 Temperature Measurement, Probe Number = 4, T = 19.860000 C 11:44:27 Temperature Measurement, Probe Number = 5, T = 19.872000 C 11:44:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:44:27 Integrated Voltage Measurement... 11:44:49 Voltage Offset Correction: v_off_ini = -0.000000958 V, v_off_fin = -0.000000527 V 11:44:49 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158424815 Vs 11:44:49 Integrated Voltage Measurement... 11:45:12 Voltage Offset Correction: v_off_ini = -0.000000190 V, v_off_fin = -0.000001990 V 11:45:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399486 Vs 11:45:26 Temperature Measurement, Probe Number = 0, T = 19.904000 C 11:45:26 Temperature Measurement, Probe Number = 1, T = 19.915000 C 11:45:27 Temperature Measurement, Probe Number = 2, T = 19.887000 C 11:45:27 Temperature Measurement, Probe Number = 3, T = 19.820000 C 11:45:28 Temperature Measurement, Probe Number = 4, T = 19.861000 C 11:45:29 Temperature Measurement, Probe Number = 5, T = 19.873000 C 11:45:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 11:45:29 Integrated Voltage Measurement... 11:45:51 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000001361 V 11:45:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158428698 Vs 11:45:52 Integrated Voltage Measurement... 11:46:14 Voltage Offset Correction: v_off_ini = -0.000002048 V, v_off_fin = -0.000001434 V 11:46:14 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158388174 Vs 12:42:28 Temperature Measurement, Probe Number = 0, T = 19.914000 C 12:42:28 Temperature Measurement, Probe Number = 1, T = 19.925000 C 12:42:29 Temperature Measurement, Probe Number = 2, T = 19.896000 C 12:42:29 Temperature Measurement, Probe Number = 3, T = 19.838000 C 12:42:30 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:42:31 Temperature Measurement, Probe Number = 5, T = 19.881000 C 12:42:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:42:31 Integrated Voltage Measurement... 12:42:53 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = 0.000000820 V 12:42:54 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158477036 Vs 12:42:54 Integrated Voltage Measurement... 12:43:16 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000001749 V 12:43:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390249 Vs 12:43:30 Temperature Measurement, Probe Number = 0, T = 19.968000 C 12:43:30 Temperature Measurement, Probe Number = 1, T = 19.926000 C 12:43:31 Temperature Measurement, Probe Number = 2, T = 19.898000 C 12:43:32 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:43:32 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:43:33 Temperature Measurement, Probe Number = 5, T = 19.882000 C 12:43:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:43:33 Integrated Voltage Measurement... 12:43:55 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000002378 V 12:43:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158435303 Vs 12:43:55 Integrated Voltage Measurement... 12:44:17 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000002224 V 12:44:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158408129 Vs 12:44:31 Temperature Measurement, Probe Number = 0, T = 19.969000 C 12:44:32 Temperature Measurement, Probe Number = 1, T = 19.927000 C 12:44:32 Temperature Measurement, Probe Number = 2, T = 19.897000 C 12:44:33 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:44:34 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:44:34 Temperature Measurement, Probe Number = 5, T = 19.882000 C 12:44:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:44:34 Integrated Voltage Measurement... 12:44:56 Voltage Offset Correction: v_off_ini = -0.000000746 V, v_off_fin = -0.000001170 V 12:44:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158423917 Vs 12:44:57 Integrated Voltage Measurement... 12:45:19 Voltage Offset Correction: v_off_ini = -0.000000358 V, v_off_fin = -0.000002165 V 12:45:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398182 Vs 12:45:33 Temperature Measurement, Probe Number = 0, T = 19.972000 C 12:45:34 Temperature Measurement, Probe Number = 1, T = 19.925000 C 12:45:34 Temperature Measurement, Probe Number = 2, T = 19.897000 C 12:45:35 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:45:35 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:45:36 Temperature Measurement, Probe Number = 5, T = 19.880000 C 12:45:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:45:36 Integrated Voltage Measurement... 12:45:58 Voltage Offset Correction: v_off_ini = -0.000001895 V, v_off_fin = -0.000001376 V 12:45:58 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158430679 Vs 12:45:58 Integrated Voltage Measurement... 12:46:20 Voltage Offset Correction: v_off_ini = 0.000000168 V, v_off_fin = -0.000002780 V 12:46:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399463 Vs 12:46:34 Temperature Measurement, Probe Number = 0, T = 19.974000 C 12:46:35 Temperature Measurement, Probe Number = 1, T = 19.926000 C 12:46:35 Temperature Measurement, Probe Number = 2, T = 19.898000 C 12:46:36 Temperature Measurement, Probe Number = 3, T = 19.841000 C 12:46:36 Temperature Measurement, Probe Number = 4, T = 19.871000 C 12:46:37 Temperature Measurement, Probe Number = 5, T = 19.881000 C 12:46:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:46:37 Integrated Voltage Measurement... 12:46:59 Voltage Offset Correction: v_off_ini = -0.000000520 V, v_off_fin = -0.000000454 V 12:46:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414594 Vs 12:46:59 Integrated Voltage Measurement... 12:47:22 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000002816 V 12:47:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381714 Vs 12:47:35 Temperature Measurement, Probe Number = 0, T = 19.975000 C 12:47:36 Temperature Measurement, Probe Number = 1, T = 19.925000 C 12:47:36 Temperature Measurement, Probe Number = 2, T = 19.897000 C 12:47:37 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:47:38 Temperature Measurement, Probe Number = 4, T = 19.871000 C 12:47:38 Temperature Measurement, Probe Number = 5, T = 19.881000 C 12:47:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:47:38 Integrated Voltage Measurement... 12:48:00 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000000732 V 12:48:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422223 Vs 12:48:00 Integrated Voltage Measurement... 12:48:23 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000005166 V 12:48:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381958 Vs 12:48:36 Temperature Measurement, Probe Number = 0, T = 19.951000 C 12:48:37 Temperature Measurement, Probe Number = 1, T = 19.925000 C 12:48:37 Temperature Measurement, Probe Number = 2, T = 19.898000 C 12:48:38 Temperature Measurement, Probe Number = 3, T = 19.839000 C 12:48:39 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:48:39 Temperature Measurement, Probe Number = 5, T = 19.880000 C 12:48:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:48:39 Integrated Voltage Measurement... 12:49:02 Voltage Offset Correction: v_off_ini = -0.000001485 V, v_off_fin = 0.000000124 V 12:49:02 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158399710 Vs 12:49:02 Integrated Voltage Measurement... 12:49:24 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000002078 V 12:49:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403750 Vs 12:49:38 Temperature Measurement, Probe Number = 0, T = 19.941000 C 12:49:38 Temperature Measurement, Probe Number = 1, T = 19.922000 C 12:49:39 Temperature Measurement, Probe Number = 2, T = 19.895000 C 12:49:40 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:49:40 Temperature Measurement, Probe Number = 4, T = 19.869000 C 12:49:41 Temperature Measurement, Probe Number = 5, T = 19.880000 C 12:49:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:49:41 Integrated Voltage Measurement... 12:50:03 Voltage Offset Correction: v_off_ini = -0.000001704 V, v_off_fin = 0.000001141 V 12:50:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158426625 Vs 12:50:03 Integrated Voltage Measurement... 12:50:25 Voltage Offset Correction: v_off_ini = -0.000001932 V, v_off_fin = -0.000003484 V 12:50:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380506 Vs 12:50:39 Temperature Measurement, Probe Number = 0, T = 19.961000 C 12:50:40 Temperature Measurement, Probe Number = 1, T = 19.923000 C 12:50:40 Temperature Measurement, Probe Number = 2, T = 19.898000 C 12:50:41 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:50:42 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:50:42 Temperature Measurement, Probe Number = 5, T = 19.880000 C 12:50:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:50:42 Integrated Voltage Measurement... 12:51:04 Voltage Offset Correction: v_off_ini = -0.000000629 V, v_off_fin = -0.000000856 V 12:51:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431713 Vs 12:51:04 Integrated Voltage Measurement... 12:51:26 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000002334 V 12:51:27 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158392053 Vs 12:51:40 Temperature Measurement, Probe Number = 0, T = 19.949000 C 12:51:41 Temperature Measurement, Probe Number = 1, T = 19.923000 C 12:51:41 Temperature Measurement, Probe Number = 2, T = 19.899000 C 12:51:42 Temperature Measurement, Probe Number = 3, T = 19.840000 C 12:51:42 Temperature Measurement, Probe Number = 4, T = 19.870000 C 12:51:43 Temperature Measurement, Probe Number = 5, T = 19.879000 C 12:51:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.88 12:51:43 Integrated Voltage Measurement... 12:52:05 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000000388 V 12:52:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421328 Vs 12:52:05 Integrated Voltage Measurement... 12:52:34 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = -0.000000703 V 12:52:34 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158388903 Vs 13:48:48 Temperature Measurement, Probe Number = 0, T = 20.023000 C 13:48:48 Temperature Measurement, Probe Number = 1, T = 19.934000 C 13:48:49 Temperature Measurement, Probe Number = 2, T = 19.908000 C 13:48:49 Temperature Measurement, Probe Number = 3, T = 19.859000 C 13:48:50 Temperature Measurement, Probe Number = 4, T = 19.882000 C 13:48:51 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:48:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:48:51 Integrated Voltage Measurement... 13:49:13 Voltage Offset Correction: v_off_ini = -0.000001185 V, v_off_fin = -0.000001910 V 13:49:14 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158454936 Vs 13:49:14 Integrated Voltage Measurement... 13:49:36 Voltage Offset Correction: v_off_ini = -0.000001047 V, v_off_fin = -0.000003037 V 13:49:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395618 Vs 13:49:50 Temperature Measurement, Probe Number = 0, T = 20.015000 C 13:49:51 Temperature Measurement, Probe Number = 1, T = 19.936000 C 13:49:51 Temperature Measurement, Probe Number = 2, T = 19.910000 C 13:49:52 Temperature Measurement, Probe Number = 3, T = 19.859000 C 13:49:52 Temperature Measurement, Probe Number = 4, T = 19.883000 C 13:49:53 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:49:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:49:53 Integrated Voltage Measurement... 13:50:15 Voltage Offset Correction: v_off_ini = -0.000000937 V, v_off_fin = -0.000002283 V 13:50:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158423831 Vs 13:50:15 Integrated Voltage Measurement... 13:50:38 Voltage Offset Correction: v_off_ini = -0.000002262 V, v_off_fin = -0.000002027 V 13:50:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393753 Vs 13:50:52 Temperature Measurement, Probe Number = 0, T = 20.007000 C 13:50:52 Temperature Measurement, Probe Number = 1, T = 19.932000 C 13:50:53 Temperature Measurement, Probe Number = 2, T = 19.908000 C 13:50:54 Temperature Measurement, Probe Number = 3, T = 19.859000 C 13:50:54 Temperature Measurement, Probe Number = 4, T = 19.882000 C 13:50:55 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:50:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:50:55 Integrated Voltage Measurement... 13:51:17 Voltage Offset Correction: v_off_ini = -0.000001734 V, v_off_fin = -0.000000322 V 13:51:17 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420671 Vs 13:51:17 Integrated Voltage Measurement... 13:51:39 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = -0.000004273 V 13:51:39 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158368079 Vs 13:51:53 Temperature Measurement, Probe Number = 0, T = 20.014000 C 13:51:54 Temperature Measurement, Probe Number = 1, T = 19.935000 C 13:51:54 Temperature Measurement, Probe Number = 2, T = 19.910000 C 13:51:55 Temperature Measurement, Probe Number = 3, T = 19.860000 C 13:51:55 Temperature Measurement, Probe Number = 4, T = 19.883000 C 13:51:56 Temperature Measurement, Probe Number = 5, T = 19.889000 C 13:51:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:51:56 Integrated Voltage Measurement... 13:52:18 Voltage Offset Correction: v_off_ini = -0.000002173 V, v_off_fin = -0.000001405 V 13:52:18 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158426224 Vs 13:52:18 Integrated Voltage Measurement... 13:52:40 Voltage Offset Correction: v_off_ini = 0.000000461 V, v_off_fin = -0.000000607 V 13:52:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402475 Vs 13:52:54 Temperature Measurement, Probe Number = 0, T = 20.019000 C 13:52:54 Temperature Measurement, Probe Number = 1, T = 19.934000 C 13:52:55 Temperature Measurement, Probe Number = 2, T = 19.911000 C 13:52:56 Temperature Measurement, Probe Number = 3, T = 19.860000 C 13:52:56 Temperature Measurement, Probe Number = 4, T = 19.883000 C 13:52:57 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:52:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:52:57 Integrated Voltage Measurement... 13:53:19 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000000307 V 13:53:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418891 Vs 13:53:19 Integrated Voltage Measurement... 13:53:41 Voltage Offset Correction: v_off_ini = 0.000000563 V, v_off_fin = -0.000003666 V 13:53:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396744 Vs 13:53:55 Temperature Measurement, Probe Number = 0, T = 20.015000 C 13:53:55 Temperature Measurement, Probe Number = 1, T = 19.936000 C 13:53:56 Temperature Measurement, Probe Number = 2, T = 19.910000 C 13:53:57 Temperature Measurement, Probe Number = 3, T = 19.862000 C 13:53:57 Temperature Measurement, Probe Number = 4, T = 19.884000 C 13:53:58 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:53:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:53:58 Integrated Voltage Measurement... 13:54:20 Voltage Offset Correction: v_off_ini = -0.000002283 V, v_off_fin = -0.000000285 V 13:54:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158429389 Vs 13:54:20 Integrated Voltage Measurement... 13:54:43 Voltage Offset Correction: v_off_ini = 0.000002356 V, v_off_fin = -0.000001800 V 13:54:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427590 Vs 13:54:56 Temperature Measurement, Probe Number = 0, T = 19.996000 C 13:54:57 Temperature Measurement, Probe Number = 1, T = 19.935000 C 13:54:57 Temperature Measurement, Probe Number = 2, T = 19.910000 C 13:54:58 Temperature Measurement, Probe Number = 3, T = 19.861000 C 13:54:59 Temperature Measurement, Probe Number = 4, T = 19.883000 C 13:54:59 Temperature Measurement, Probe Number = 5, T = 19.890000 C 13:54:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:54:59 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000000117 V 13:55:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403111 Vs 13:55:22 Integrated Voltage Measurement... 13:55:44 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = -0.000001874 V 13:55:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158406337 Vs 13:55:57 Temperature Measurement, Probe Number = 0, T = 19.999000 C 13:55:58 Temperature Measurement, Probe Number = 1, T = 19.936000 C 13:55:58 Temperature Measurement, Probe Number = 2, T = 19.912000 C 13:55:59 Temperature Measurement, Probe Number = 3, T = 19.862000 C 13:56:00 Temperature Measurement, Probe Number = 4, T = 19.884000 C 13:56:00 Temperature Measurement, Probe Number = 5, T = 19.891000 C 13:56:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:56:00 Integrated Voltage Measurement... 13:56:22 Voltage Offset Correction: v_off_ini = -0.000000190 V, v_off_fin = -0.000000512 V 13:56:22 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158413435 Vs 13:56:23 Integrated Voltage Measurement... 13:56:45 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000002781 V 13:56:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387965 Vs 13:56:59 Temperature Measurement, Probe Number = 0, T = 20.011000 C 13:56:59 Temperature Measurement, Probe Number = 1, T = 19.937000 C 13:57:00 Temperature Measurement, Probe Number = 2, T = 19.912000 C 13:57:01 Temperature Measurement, Probe Number = 3, T = 19.863000 C 13:57:01 Temperature Measurement, Probe Number = 4, T = 19.884000 C 13:57:02 Temperature Measurement, Probe Number = 5, T = 19.891000 C 13:57:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 13:57:02 Integrated Voltage Measurement... 13:57:24 Voltage Offset Correction: v_off_ini = -0.000001515 V, v_off_fin = -0.000000739 V 13:57:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158419925 Vs 13:57:24 Integrated Voltage Measurement... 13:57:46 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000002766 V 13:57:46 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158384881 Vs 13:58:00 Temperature Measurement, Probe Number = 0, T = 20.037000 C 13:58:00 Temperature Measurement, Probe Number = 1, T = 19.938000 C 13:58:01 Temperature Measurement, Probe Number = 2, T = 19.914000 C 13:58:02 Temperature Measurement, Probe Number = 3, T = 19.864000 C 13:58:02 Temperature Measurement, Probe Number = 4, T = 19.885000 C 13:58:03 Temperature Measurement, Probe Number = 5, T = 19.893000 C 13:58:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.89 13:58:03 Integrated Voltage Measurement... 13:58:25 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000000037 V 13:58:25 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158425218 Vs 13:58:25 Integrated Voltage Measurement... 13:58:48 Voltage Offset Correction: v_off_ini = -0.000003140 V, v_off_fin = -0.000001903 V 13:58:48 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158387379 Vs 14:55:01 Temperature Measurement, Probe Number = 0, T = 20.108000 C 14:55:02 Temperature Measurement, Probe Number = 1, T = 19.954000 C 14:55:03 Temperature Measurement, Probe Number = 2, T = 19.934000 C 14:55:03 Temperature Measurement, Probe Number = 3, T = 19.893000 C 14:55:04 Temperature Measurement, Probe Number = 4, T = 19.906000 C 14:55:04 Temperature Measurement, Probe Number = 5, T = 19.909000 C 14:55:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.93 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 14:55:04 Integrated Voltage Measurement... 14:55:27 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = 0.000000022 V 14:55:27 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158473342 Vs 14:55:27 Integrated Voltage Measurement... 14:55:49 Voltage Offset Correction: v_off_ini = 0.000001580 V, v_off_fin = -0.000004068 V 14:55:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426783 Vs 14:56:03 Temperature Measurement, Probe Number = 0, T = 20.125000 C 14:56:03 Temperature Measurement, Probe Number = 1, T = 19.956000 C 14:56:04 Temperature Measurement, Probe Number = 2, T = 19.937000 C 14:56:05 Temperature Measurement, Probe Number = 3, T = 19.893000 C 14:56:05 Temperature Measurement, Probe Number = 4, T = 19.907000 C 14:56:06 Temperature Measurement, Probe Number = 5, T = 19.910000 C 14:56:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 14:56:06 Integrated Voltage Measurement... 14:56:28 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = -0.000001170 V 14:56:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158440835 Vs 14:56:28 Integrated Voltage Measurement... 14:56:50 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = -0.000001383 V 14:56:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415668 Vs 14:57:04 Temperature Measurement, Probe Number = 0, T = 20.107000 C 14:57:04 Temperature Measurement, Probe Number = 1, T = 19.957000 C 14:57:05 Temperature Measurement, Probe Number = 2, T = 19.937000 C 14:57:06 Temperature Measurement, Probe Number = 3, T = 19.894000 C 14:57:06 Temperature Measurement, Probe Number = 4, T = 19.907000 C 14:57:07 Temperature Measurement, Probe Number = 5, T = 19.910000 C 14:57:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 14:57:07 Integrated Voltage Measurement... 14:57:29 Voltage Offset Correction: v_off_ini = -0.000002451 V, v_off_fin = -0.000002502 V 14:57:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158443259 Vs 14:57:29 Integrated Voltage Measurement... 14:57:52 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000002415 V 14:57:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404849 Vs 14:58:05 Temperature Measurement, Probe Number = 0, T = 20.121000 C 14:58:06 Temperature Measurement, Probe Number = 1, T = 19.957000 C 14:58:06 Temperature Measurement, Probe Number = 2, T = 19.938000 C 14:58:07 Temperature Measurement, Probe Number = 3, T = 19.895000 C 14:58:08 Temperature Measurement, Probe Number = 4, T = 19.908000 C 14:58:08 Temperature Measurement, Probe Number = 5, T = 19.910000 C 14:58:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 14:58:08 Integrated Voltage Measurement... 14:58:36 Voltage Offset Correction: v_off_ini = -0.000002144 V, v_off_fin = -0.000006117 V 14:58:36 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158492559 Vs 14:58:36 Integrated Voltage Measurement... 14:58:58 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000003827 V 14:58:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158376371 Vs 14:59:12 Temperature Measurement, Probe Number = 0, T = 20.143000 C 14:59:13 Temperature Measurement, Probe Number = 1, T = 19.958000 C 14:59:13 Temperature Measurement, Probe Number = 2, T = 19.939000 C 14:59:14 Temperature Measurement, Probe Number = 3, T = 19.896000 C 14:59:14 Temperature Measurement, Probe Number = 4, T = 19.909000 C 14:59:15 Temperature Measurement, Probe Number = 5, T = 19.911000 C 14:59:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 14:59:15 Integrated Voltage Measurement... 14:59:37 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000702 V 14:59:37 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158426707 Vs 14:59:37 Integrated Voltage Measurement... 14:59:59 Voltage Offset Correction: v_off_ini = -0.000002940 V, v_off_fin = -0.000001580 V 14:59:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392513 Vs 15:00:13 Temperature Measurement, Probe Number = 0, T = 20.146000 C 15:00:14 Temperature Measurement, Probe Number = 1, T = 19.958000 C 15:00:14 Temperature Measurement, Probe Number = 2, T = 19.939000 C 15:00:15 Temperature Measurement, Probe Number = 3, T = 19.896000 C 15:00:15 Temperature Measurement, Probe Number = 4, T = 19.909000 C 15:00:16 Temperature Measurement, Probe Number = 5, T = 19.911000 C 15:00:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 15:00:16 Integrated Voltage Measurement... 15:00:38 Voltage Offset Correction: v_off_ini = -0.000002231 V, v_off_fin = -0.000000490 V 15:00:39 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158434140 Vs 15:00:39 Integrated Voltage Measurement... 15:01:01 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000002495 V 15:01:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381049 Vs 15:01:15 Temperature Measurement, Probe Number = 0, T = 20.162000 C 15:01:15 Temperature Measurement, Probe Number = 1, T = 19.959000 C 15:01:16 Temperature Measurement, Probe Number = 2, T = 19.941000 C 15:01:16 Temperature Measurement, Probe Number = 3, T = 19.897000 C 15:01:17 Temperature Measurement, Probe Number = 4, T = 19.910000 C 15:01:18 Temperature Measurement, Probe Number = 5, T = 19.912000 C 15:01:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 15:01:18 Integrated Voltage Measurement... 15:01:40 Voltage Offset Correction: v_off_ini = -0.000002144 V, v_off_fin = -0.000002100 V 15:01:40 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158437855 Vs 15:01:40 Integrated Voltage Measurement... 15:02:02 Voltage Offset Correction: v_off_ini = -0.000003892 V, v_off_fin = -0.000003439 V 15:02:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370410 Vs 15:02:16 Temperature Measurement, Probe Number = 0, T = 20.180000 C 15:02:16 Temperature Measurement, Probe Number = 1, T = 19.959000 C 15:02:17 Temperature Measurement, Probe Number = 2, T = 19.941000 C 15:02:17 Temperature Measurement, Probe Number = 3, T = 19.897000 C 15:02:18 Temperature Measurement, Probe Number = 4, T = 19.910000 C 15:02:19 Temperature Measurement, Probe Number = 5, T = 19.913000 C 15:02:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 15:02:19 Integrated Voltage Measurement... 15:02:41 Voltage Offset Correction: v_off_ini = -0.000002246 V, v_off_fin = 0.000001683 V 15:02:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410415 Vs 15:02:41 Integrated Voltage Measurement... 15:03:03 Voltage Offset Correction: v_off_ini = -0.000003227 V, v_off_fin = -0.000002817 V 15:03:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382332 Vs 15:03:17 Temperature Measurement, Probe Number = 0, T = 20.158000 C 15:03:17 Temperature Measurement, Probe Number = 1, T = 19.960000 C 15:03:18 Temperature Measurement, Probe Number = 2, T = 19.942000 C 15:03:18 Temperature Measurement, Probe Number = 3, T = 19.897000 C 15:03:19 Temperature Measurement, Probe Number = 4, T = 19.911000 C 15:03:20 Temperature Measurement, Probe Number = 5, T = 19.913000 C 15:03:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 15:03:20 Integrated Voltage Measurement... 15:03:42 Voltage Offset Correction: v_off_ini = -0.000001961 V, v_off_fin = -0.000001207 V 15:03:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158428392 Vs 15:03:42 Integrated Voltage Measurement... 15:04:04 Voltage Offset Correction: v_off_ini = 0.000001551 V, v_off_fin = -0.000002729 V 15:04:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412619 Vs 15:04:18 Temperature Measurement, Probe Number = 0, T = 20.154000 C 15:04:18 Temperature Measurement, Probe Number = 1, T = 19.961000 C 15:04:19 Temperature Measurement, Probe Number = 2, T = 19.942000 C 15:04:20 Temperature Measurement, Probe Number = 3, T = 19.897000 C 15:04:20 Temperature Measurement, Probe Number = 4, T = 19.912000 C 15:04:21 Temperature Measurement, Probe Number = 5, T = 19.913000 C 15:04:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.90 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 15:04:21 Integrated Voltage Measurement... 15:04:43 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000002122 V 15:04:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158440836 Vs 15:04:43 Integrated Voltage Measurement... 15:05:06 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = -0.000004267 V 15:05:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371312 Vs 16:01:19 Temperature Measurement, Probe Number = 0, T = 20.255000 C 16:01:20 Temperature Measurement, Probe Number = 1, T = 19.985000 C 16:01:20 Temperature Measurement, Probe Number = 2, T = 19.969000 C 16:01:21 Temperature Measurement, Probe Number = 3, T = 19.935000 C 16:01:22 Temperature Measurement, Probe Number = 4, T = 19.941000 C 16:01:22 Temperature Measurement, Probe Number = 5, T = 19.938000 C 16:01:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:01:22 Integrated Voltage Measurement... 16:01:45 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000001098 V 16:01:45 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.158502267 Vs 16:01:45 Integrated Voltage Measurement... 16:02:07 Voltage Offset Correction: v_off_ini = -0.000000322 V, v_off_fin = -0.000002400 V 16:02:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395554 Vs 16:02:21 Temperature Measurement, Probe Number = 0, T = 20.248000 C 16:02:22 Temperature Measurement, Probe Number = 1, T = 19.985000 C 16:02:22 Temperature Measurement, Probe Number = 2, T = 19.971000 C 16:02:23 Temperature Measurement, Probe Number = 3, T = 19.935000 C 16:02:23 Temperature Measurement, Probe Number = 4, T = 19.942000 C 16:02:24 Temperature Measurement, Probe Number = 5, T = 19.938000 C 16:02:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:02:24 Integrated Voltage Measurement... 16:02:46 Voltage Offset Correction: v_off_ini = -0.000000285 V, v_off_fin = -0.000000461 V 16:02:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409919 Vs 16:02:46 Integrated Voltage Measurement... 16:03:09 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000002379 V 16:03:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389314 Vs 16:03:22 Temperature Measurement, Probe Number = 0, T = 20.236000 C 16:03:23 Temperature Measurement, Probe Number = 1, T = 19.984000 C 16:03:23 Temperature Measurement, Probe Number = 2, T = 19.970000 C 16:03:24 Temperature Measurement, Probe Number = 3, T = 19.936000 C 16:03:25 Temperature Measurement, Probe Number = 4, T = 19.941000 C 16:03:25 Temperature Measurement, Probe Number = 5, T = 19.938000 C 16:03:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:03:25 Integrated Voltage Measurement... 16:03:47 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000001653 V 16:03:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158426320 Vs 16:03:47 Integrated Voltage Measurement... 16:04:09 Voltage Offset Correction: v_off_ini = -0.000001873 V, v_off_fin = -0.000002473 V 16:04:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385677 Vs 16:04:23 Temperature Measurement, Probe Number = 0, T = 20.253000 C 16:04:24 Temperature Measurement, Probe Number = 1, T = 19.987000 C 16:04:24 Temperature Measurement, Probe Number = 2, T = 19.973000 C 16:04:25 Temperature Measurement, Probe Number = 3, T = 19.938000 C 16:04:25 Temperature Measurement, Probe Number = 4, T = 19.943000 C 16:04:26 Temperature Measurement, Probe Number = 5, T = 19.940000 C 16:04:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:04:26 Integrated Voltage Measurement... 16:04:48 Voltage Offset Correction: v_off_ini = -0.000001910 V, v_off_fin = -0.000000849 V 16:04:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417278 Vs 16:04:49 Integrated Voltage Measurement... 16:05:11 Voltage Offset Correction: v_off_ini = -0.000001493 V, v_off_fin = -0.000002964 V 16:05:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380295 Vs 16:05:25 Temperature Measurement, Probe Number = 0, T = 20.241000 C 16:05:25 Temperature Measurement, Probe Number = 1, T = 19.988000 C 16:05:26 Temperature Measurement, Probe Number = 2, T = 19.974000 C 16:05:27 Temperature Measurement, Probe Number = 3, T = 19.937000 C 16:05:27 Temperature Measurement, Probe Number = 4, T = 19.944000 C 16:05:28 Temperature Measurement, Probe Number = 5, T = 19.940000 C 16:05:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:05:28 Integrated Voltage Measurement... 16:05:50 Voltage Offset Correction: v_off_ini = -0.000003753 V, v_off_fin = 0.000001332 V 16:05:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158414383 Vs 16:05:50 Integrated Voltage Measurement... 16:06:12 Voltage Offset Correction: v_off_ini = -0.000003440 V, v_off_fin = -0.000003110 V 16:06:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158354263 Vs 16:06:26 Temperature Measurement, Probe Number = 0, T = 20.254000 C 16:06:26 Temperature Measurement, Probe Number = 1, T = 19.988000 C 16:06:27 Temperature Measurement, Probe Number = 2, T = 19.974000 C 16:06:28 Temperature Measurement, Probe Number = 3, T = 19.939000 C 16:06:28 Temperature Measurement, Probe Number = 4, T = 19.944000 C 16:06:29 Temperature Measurement, Probe Number = 5, T = 19.940000 C 16:06:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.94 16:06:29 Integrated Voltage Measurement... 16:06:51 Voltage Offset Correction: v_off_ini = -0.000003066 V, v_off_fin = -0.000000702 V 16:06:51 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158426428 Vs 16:06:51 Integrated Voltage Measurement... 16:07:13 Voltage Offset Correction: v_off_ini = 0.000000432 V, v_off_fin = -0.000001522 V 16:07:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403869 Vs 16:07:27 Temperature Measurement, Probe Number = 0, T = 20.235000 C 16:07:28 Temperature Measurement, Probe Number = 1, T = 19.989000 C 16:07:28 Temperature Measurement, Probe Number = 2, T = 19.976000 C 16:07:29 Temperature Measurement, Probe Number = 3, T = 19.940000 C 16:07:30 Temperature Measurement, Probe Number = 4, T = 19.945000 C 16:07:30 Temperature Measurement, Probe Number = 5, T = 19.941000 C 16:07:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 16:07:30 Integrated Voltage Measurement... 16:07:52 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000000615 V 16:07:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158412776 Vs 16:07:52 Integrated Voltage Measurement... 16:08:15 Voltage Offset Correction: v_off_ini = 0.000000790 V, v_off_fin = -0.000001676 V 16:08:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422066 Vs 16:08:29 Temperature Measurement, Probe Number = 0, T = 20.228000 C 16:08:29 Temperature Measurement, Probe Number = 1, T = 19.989000 C 16:08:30 Temperature Measurement, Probe Number = 2, T = 19.977000 C 16:08:30 Temperature Measurement, Probe Number = 3, T = 19.941000 C 16:08:31 Temperature Measurement, Probe Number = 4, T = 19.945000 C 16:08:32 Temperature Measurement, Probe Number = 5, T = 19.941000 C 16:08:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 16:08:32 Integrated Voltage Measurement... 16:08:54 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000004588 V 16:08:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158428580 Vs 16:08:54 Integrated Voltage Measurement... 16:09:16 Voltage Offset Correction: v_off_ini = -0.000001119 V, v_off_fin = -0.000000629 V 16:09:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407337 Vs 16:09:30 Temperature Measurement, Probe Number = 0, T = 20.230000 C 16:09:31 Temperature Measurement, Probe Number = 1, T = 19.989000 C 16:09:31 Temperature Measurement, Probe Number = 2, T = 19.976000 C 16:09:32 Temperature Measurement, Probe Number = 3, T = 19.940000 C 16:09:33 Temperature Measurement, Probe Number = 4, T = 19.946000 C 16:09:33 Temperature Measurement, Probe Number = 5, T = 19.941000 C 16:09:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 16:09:33 Integrated Voltage Measurement... 16:09:55 Voltage Offset Correction: v_off_ini = -0.000002165 V, v_off_fin = -0.000001024 V 16:09:55 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158414830 Vs 16:09:55 Integrated Voltage Measurement... 16:10:18 Voltage Offset Correction: v_off_ini = -0.000001477 V, v_off_fin = -0.000001858 V 16:10:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382300 Vs 16:10:32 Temperature Measurement, Probe Number = 0, T = 20.229000 C 16:10:32 Temperature Measurement, Probe Number = 1, T = 19.988000 C 16:10:33 Temperature Measurement, Probe Number = 2, T = 19.977000 C 16:10:33 Temperature Measurement, Probe Number = 3, T = 19.940000 C 16:10:34 Temperature Measurement, Probe Number = 4, T = 19.945000 C 16:10:35 Temperature Measurement, Probe Number = 5, T = 19.940000 C 16:10:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 16:10:35 Integrated Voltage Measurement... 16:10:57 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000001273 V 16:10:57 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158422759 Vs 16:10:57 Integrated Voltage Measurement... 16:11:19 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000002487 V 16:11:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389914 Vs 17:07:33 Temperature Measurement, Probe Number = 0, T = 20.274000 C 17:07:34 Temperature Measurement, Probe Number = 1, T = 20.014000 C 17:07:34 Temperature Measurement, Probe Number = 2, T = 20.004000 C 17:07:35 Temperature Measurement, Probe Number = 3, T = 19.969000 C 17:07:36 Temperature Measurement, Probe Number = 4, T = 19.977000 C 17:07:36 Temperature Measurement, Probe Number = 5, T = 19.968000 C 17:07:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:07:36 Integrated Voltage Measurement... 17:07:59 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000000249 V 17:07:59 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158482470 Vs 17:07:59 Integrated Voltage Measurement... 17:08:21 Voltage Offset Correction: v_off_ini = 0.000000980 V, v_off_fin = -0.000002670 V 17:08:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158409276 Vs 17:08:35 Temperature Measurement, Probe Number = 0, T = 20.252000 C 17:08:35 Temperature Measurement, Probe Number = 1, T = 20.016000 C 17:08:36 Temperature Measurement, Probe Number = 2, T = 20.008000 C 17:08:36 Temperature Measurement, Probe Number = 3, T = 19.970000 C 17:08:37 Temperature Measurement, Probe Number = 4, T = 19.977000 C 17:08:38 Temperature Measurement, Probe Number = 5, T = 19.969000 C 17:08:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:08:38 Integrated Voltage Measurement... 17:09:00 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = 0.000003936 V 17:09:00 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158373464 Vs 17:09:00 Integrated Voltage Measurement... 17:09:22 Voltage Offset Correction: v_off_ini = -0.000002612 V, v_off_fin = -0.000002722 V 17:09:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367305 Vs 17:09:36 Temperature Measurement, Probe Number = 0, T = 20.269000 C 17:09:36 Temperature Measurement, Probe Number = 1, T = 20.016000 C 17:09:37 Temperature Measurement, Probe Number = 2, T = 20.009000 C 17:09:38 Temperature Measurement, Probe Number = 3, T = 19.972000 C 17:09:38 Temperature Measurement, Probe Number = 4, T = 19.978000 C 17:09:39 Temperature Measurement, Probe Number = 5, T = 19.969000 C 17:09:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:09:39 Integrated Voltage Measurement... 17:10:01 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000000190 V 17:10:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405211 Vs 17:10:01 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = -0.000001851 V, v_off_fin = 0.000000322 V 17:10:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393724 Vs 17:10:38 Temperature Measurement, Probe Number = 0, T = 20.260000 C 17:10:38 Temperature Measurement, Probe Number = 1, T = 20.016000 C 17:10:39 Temperature Measurement, Probe Number = 2, T = 20.009000 C 17:10:40 Temperature Measurement, Probe Number = 3, T = 19.972000 C 17:10:40 Temperature Measurement, Probe Number = 4, T = 19.979000 C 17:10:41 Temperature Measurement, Probe Number = 5, T = 19.970000 C 17:10:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:10:41 Integrated Voltage Measurement... 17:11:03 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = 0.000000285 V 17:11:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407367 Vs 17:11:03 Integrated Voltage Measurement... 17:11:25 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = -0.000002926 V 17:11:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393294 Vs 17:11:39 Temperature Measurement, Probe Number = 0, T = 20.245000 C 17:11:39 Temperature Measurement, Probe Number = 1, T = 20.016000 C 17:11:40 Temperature Measurement, Probe Number = 2, T = 20.008000 C 17:11:41 Temperature Measurement, Probe Number = 3, T = 19.974000 C 17:11:41 Temperature Measurement, Probe Number = 4, T = 19.979000 C 17:11:42 Temperature Measurement, Probe Number = 5, T = 19.968000 C 17:11:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:11:42 Integrated Voltage Measurement... 17:12:04 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = 0.000001544 V 17:12:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399907 Vs 17:12:04 Integrated Voltage Measurement... 17:12:26 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000002897 V 17:12:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370632 Vs 17:12:40 Temperature Measurement, Probe Number = 0, T = 20.249000 C 17:12:40 Temperature Measurement, Probe Number = 1, T = 20.018000 C 17:12:41 Temperature Measurement, Probe Number = 2, T = 20.011000 C 17:12:42 Temperature Measurement, Probe Number = 3, T = 19.975000 C 17:12:42 Temperature Measurement, Probe Number = 4, T = 19.979000 C 17:12:43 Temperature Measurement, Probe Number = 5, T = 19.969000 C 17:12:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:12:43 Integrated Voltage Measurement... 17:13:05 Voltage Offset Correction: v_off_ini = -0.000000476 V, v_off_fin = -0.000000051 V 17:13:05 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158407648 Vs 17:13:05 Integrated Voltage Measurement... 17:13:27 Voltage Offset Correction: v_off_ini = -0.000000271 V, v_off_fin = -0.000003176 V 17:13:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393849 Vs 17:13:41 Temperature Measurement, Probe Number = 0, T = 20.251000 C 17:13:42 Temperature Measurement, Probe Number = 1, T = 20.018000 C 17:13:42 Temperature Measurement, Probe Number = 2, T = 20.009000 C 17:13:43 Temperature Measurement, Probe Number = 3, T = 19.974000 C 17:13:44 Temperature Measurement, Probe Number = 4, T = 19.979000 C 17:13:44 Temperature Measurement, Probe Number = 5, T = 19.969000 C 17:13:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:13:44 Integrated Voltage Measurement... 17:14:06 Voltage Offset Correction: v_off_ini = -0.000002532 V, v_off_fin = -0.000001200 V 17:14:06 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158443739 Vs 17:14:06 Integrated Voltage Measurement... 17:14:29 Voltage Offset Correction: v_off_ini = -0.000002795 V, v_off_fin = -0.000002254 V 17:14:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389683 Vs 17:14:42 Temperature Measurement, Probe Number = 0, T = 20.249000 C 17:14:43 Temperature Measurement, Probe Number = 1, T = 20.017000 C 17:14:44 Temperature Measurement, Probe Number = 2, T = 20.010000 C 17:14:44 Temperature Measurement, Probe Number = 3, T = 19.975000 C 17:14:45 Temperature Measurement, Probe Number = 4, T = 19.979000 C 17:14:45 Temperature Measurement, Probe Number = 5, T = 19.970000 C 17:14:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:14:45 Integrated Voltage Measurement... 17:15:08 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000000585 V 17:15:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158416811 Vs 17:15:08 Integrated Voltage Measurement... 17:15:31 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = -0.000002839 V 17:15:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369812 Vs 17:15:44 Temperature Measurement, Probe Number = 0, T = 20.242000 C 17:15:45 Temperature Measurement, Probe Number = 1, T = 20.019000 C 17:15:45 Temperature Measurement, Probe Number = 2, T = 20.012000 C 17:15:46 Temperature Measurement, Probe Number = 3, T = 19.975000 C 17:15:47 Temperature Measurement, Probe Number = 4, T = 19.981000 C 17:15:47 Temperature Measurement, Probe Number = 5, T = 19.971000 C 17:15:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:15:47 Integrated Voltage Measurement... 17:16:09 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000000980 V 17:16:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421739 Vs 17:16:09 Integrated Voltage Measurement... 17:16:32 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = -0.000001207 V 17:16:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397146 Vs 17:16:46 Temperature Measurement, Probe Number = 0, T = 20.256000 C 17:16:46 Temperature Measurement, Probe Number = 1, T = 20.018000 C 17:16:47 Temperature Measurement, Probe Number = 2, T = 20.012000 C 17:16:48 Temperature Measurement, Probe Number = 3, T = 19.975000 C 17:16:48 Temperature Measurement, Probe Number = 4, T = 19.981000 C 17:16:49 Temperature Measurement, Probe Number = 5, T = 19.971000 C 17:16:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 17:16:49 Integrated Voltage Measurement... 17:17:11 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000000249 V 17:17:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409607 Vs 17:17:11 Integrated Voltage Measurement... 17:17:34 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000003570 V 17:17:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384161 Vs 18:13:47 Temperature Measurement, Probe Number = 0, T = 20.296000 C 18:13:48 Temperature Measurement, Probe Number = 1, T = 20.040000 C 18:13:49 Temperature Measurement, Probe Number = 2, T = 20.038000 C 18:13:49 Temperature Measurement, Probe Number = 3, T = 20.004000 C 18:13:50 Temperature Measurement, Probe Number = 4, T = 20.011000 C 18:13:50 Temperature Measurement, Probe Number = 5, T = 19.994000 C 18:13:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 18:13:50 Integrated Voltage Measurement... 18:14:13 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = 0.000000117 V 18:14:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.158445521 Vs 18:14:13 Integrated Voltage Measurement... 18:14:35 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000003417 V 18:14:35 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158386640 Vs 18:14:48 Temperature Measurement, Probe Number = 0, T = 20.308000 C 18:14:49 Temperature Measurement, Probe Number = 1, T = 20.041000 C 18:14:50 Temperature Measurement, Probe Number = 2, T = 20.040000 C 18:14:50 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:14:51 Temperature Measurement, Probe Number = 4, T = 20.012000 C 18:14:51 Temperature Measurement, Probe Number = 5, T = 19.994000 C 18:14:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 18:14:51 Integrated Voltage Measurement... 18:15:14 Voltage Offset Correction: v_off_ini = -0.000002143 V, v_off_fin = -0.000001412 V 18:15:14 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158421078 Vs 18:15:14 Integrated Voltage Measurement... 18:15:36 Voltage Offset Correction: v_off_ini = -0.000002494 V, v_off_fin = -0.000004857 V 18:15:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158360503 Vs 18:15:50 Temperature Measurement, Probe Number = 0, T = 20.284000 C 18:15:50 Temperature Measurement, Probe Number = 1, T = 20.043000 C 18:15:51 Temperature Measurement, Probe Number = 2, T = 20.041000 C 18:15:52 Temperature Measurement, Probe Number = 3, T = 20.004000 C 18:15:52 Temperature Measurement, Probe Number = 4, T = 20.013000 C 18:15:53 Temperature Measurement, Probe Number = 5, T = 19.996000 C 18:15:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 18:15:53 Integrated Voltage Measurement... 18:16:15 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000001565 V 18:16:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408213 Vs 18:16:15 Integrated Voltage Measurement... 18:16:38 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000002399 V 18:16:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382881 Vs 18:16:51 Temperature Measurement, Probe Number = 0, T = 20.284000 C 18:16:52 Temperature Measurement, Probe Number = 1, T = 20.043000 C 18:16:52 Temperature Measurement, Probe Number = 2, T = 20.042000 C 18:16:53 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:16:54 Temperature Measurement, Probe Number = 4, T = 20.013000 C 18:16:54 Temperature Measurement, Probe Number = 5, T = 19.996000 C 18:16:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 18:16:54 Integrated Voltage Measurement... 18:17:16 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000001009 V 18:17:16 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158413755 Vs 18:17:17 Integrated Voltage Measurement... 18:17:39 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000002780 V 18:17:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382360 Vs 18:17:53 Temperature Measurement, Probe Number = 0, T = 20.254000 C 18:17:53 Temperature Measurement, Probe Number = 1, T = 20.044000 C 18:17:54 Temperature Measurement, Probe Number = 2, T = 20.044000 C 18:17:55 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:17:55 Temperature Measurement, Probe Number = 4, T = 20.014000 C 18:17:56 Temperature Measurement, Probe Number = 5, T = 19.997000 C 18:17:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 18:17:56 Integrated Voltage Measurement... 18:18:18 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = -0.000000951 V 18:18:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392198 Vs 18:18:18 Integrated Voltage Measurement... 18:18:40 Voltage Offset Correction: v_off_ini = -0.000000622 V, v_off_fin = -0.000002823 V 18:18:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382260 Vs 18:18:54 Temperature Measurement, Probe Number = 0, T = 20.253000 C 18:18:54 Temperature Measurement, Probe Number = 1, T = 20.042000 C 18:18:55 Temperature Measurement, Probe Number = 2, T = 20.042000 C 18:18:56 Temperature Measurement, Probe Number = 3, T = 20.006000 C 18:18:56 Temperature Measurement, Probe Number = 4, T = 20.013000 C 18:18:57 Temperature Measurement, Probe Number = 5, T = 19.996000 C 18:18:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 18:18:57 Integrated Voltage Measurement... 18:19:19 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = 0.000001492 V 18:19:19 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158379087 Vs 18:19:19 Integrated Voltage Measurement... 18:19:41 Voltage Offset Correction: v_off_ini = 0.000001551 V, v_off_fin = -0.000004477 V 18:19:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394090 Vs 18:19:55 Temperature Measurement, Probe Number = 0, T = 20.260000 C 18:19:55 Temperature Measurement, Probe Number = 1, T = 20.045000 C 18:19:56 Temperature Measurement, Probe Number = 2, T = 20.046000 C 18:19:57 Temperature Measurement, Probe Number = 3, T = 20.006000 C 18:19:57 Temperature Measurement, Probe Number = 4, T = 20.014000 C 18:19:58 Temperature Measurement, Probe Number = 5, T = 19.997000 C 18:19:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 18:19:58 Integrated Voltage Measurement... 18:20:20 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001053 V 18:20:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405347 Vs 18:20:20 Integrated Voltage Measurement... 18:20:42 Voltage Offset Correction: v_off_ini = -0.000000636 V, v_off_fin = -0.000001288 V 18:20:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401377 Vs 18:20:56 Temperature Measurement, Probe Number = 0, T = 20.276000 C 18:20:56 Temperature Measurement, Probe Number = 1, T = 20.045000 C 18:20:57 Temperature Measurement, Probe Number = 2, T = 20.045000 C 18:20:58 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:20:58 Temperature Measurement, Probe Number = 4, T = 20.015000 C 18:20:59 Temperature Measurement, Probe Number = 5, T = 19.998000 C 18:20:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 18:20:59 Integrated Voltage Measurement... 18:21:21 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000000366 V 18:21:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395901 Vs 18:21:21 Integrated Voltage Measurement... 18:21:44 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000002253 V 18:21:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373216 Vs 18:21:57 Temperature Measurement, Probe Number = 0, T = 20.268000 C 18:21:58 Temperature Measurement, Probe Number = 1, T = 20.045000 C 18:21:58 Temperature Measurement, Probe Number = 2, T = 20.045000 C 18:21:59 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:22:00 Temperature Measurement, Probe Number = 4, T = 20.016000 C 18:22:00 Temperature Measurement, Probe Number = 5, T = 19.998000 C 18:22:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 18:22:00 Integrated Voltage Measurement... 18:22:22 Voltage Offset Correction: v_off_ini = -0.000001843 V, v_off_fin = -0.000001704 V 18:22:22 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158397887 Vs 18:22:22 Integrated Voltage Measurement... 18:22:44 Voltage Offset Correction: v_off_ini = 0.000000907 V, v_off_fin = -0.000003073 V 18:22:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387961 Vs 18:22:58 Temperature Measurement, Probe Number = 0, T = 20.264000 C 18:22:59 Temperature Measurement, Probe Number = 1, T = 20.045000 C 18:22:59 Temperature Measurement, Probe Number = 2, T = 20.045000 C 18:23:00 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:23:01 Temperature Measurement, Probe Number = 4, T = 20.016000 C 18:23:01 Temperature Measurement, Probe Number = 5, T = 19.998000 C 18:23:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 18:23:01 Integrated Voltage Measurement... 18:23:23 Voltage Offset Correction: v_off_ini = -0.000001587 V, v_off_fin = -0.000000870 V 18:23:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408878 Vs 18:23:23 Integrated Voltage Measurement... 18:23:46 Voltage Offset Correction: v_off_ini = 0.000003768 V, v_off_fin = -0.000001683 V 18:23:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421868 Vs 19:19:59 Temperature Measurement, Probe Number = 0, T = 20.215000 C 19:20:00 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:20:00 Temperature Measurement, Probe Number = 2, T = 20.057000 C 19:20:01 Temperature Measurement, Probe Number = 3, T = 20.015000 C 19:20:02 Temperature Measurement, Probe Number = 4, T = 20.033000 C 19:20:02 Temperature Measurement, Probe Number = 5, T = 20.012000 C 19:20:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:20:02 Integrated Voltage Measurement... 19:20:32 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = 0.011341122 V 19:20:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.035816194 Vs 19:20:33 Integrated Voltage Measurement... 19:20:55 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000001558 V 19:20:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158368840 Vs 19:21:08 Temperature Measurement, Probe Number = 0, T = 20.215000 C 19:21:09 Temperature Measurement, Probe Number = 1, T = 20.054000 C 19:21:10 Temperature Measurement, Probe Number = 2, T = 20.058000 C 19:21:10 Temperature Measurement, Probe Number = 3, T = 20.015000 C 19:21:11 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:21:11 Temperature Measurement, Probe Number = 5, T = 20.011000 C 19:21:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:21:11 Integrated Voltage Measurement... 19:21:34 Voltage Offset Correction: v_off_ini = -0.000001390 V, v_off_fin = 0.000000146 V 19:21:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158383088 Vs 19:21:34 Integrated Voltage Measurement... 19:21:56 Voltage Offset Correction: v_off_ini = 0.000000029 V, v_off_fin = -0.000003292 V 19:21:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158377599 Vs 19:22:10 Temperature Measurement, Probe Number = 0, T = 20.204000 C 19:22:10 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:22:11 Temperature Measurement, Probe Number = 2, T = 20.060000 C 19:22:11 Temperature Measurement, Probe Number = 3, T = 20.015000 C 19:22:12 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:22:13 Temperature Measurement, Probe Number = 5, T = 20.013000 C 19:22:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:22:13 Integrated Voltage Measurement... 19:22:35 Voltage Offset Correction: v_off_ini = -0.000001763 V, v_off_fin = -0.000001244 V 19:22:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158395547 Vs 19:22:35 Integrated Voltage Measurement... 19:22:57 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000002144 V 19:22:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158366561 Vs 19:23:11 Temperature Measurement, Probe Number = 0, T = 20.198000 C 19:23:11 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:23:12 Temperature Measurement, Probe Number = 2, T = 20.061000 C 19:23:12 Temperature Measurement, Probe Number = 3, T = 20.016000 C 19:23:13 Temperature Measurement, Probe Number = 4, T = 20.035000 C 19:23:14 Temperature Measurement, Probe Number = 5, T = 20.013000 C 19:23:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 19:23:14 Integrated Voltage Measurement... 19:23:36 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000000337 V 19:23:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395149 Vs 19:23:36 Integrated Voltage Measurement... 19:23:58 Voltage Offset Correction: v_off_ini = -0.000001587 V, v_off_fin = -0.000003124 V 19:23:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372605 Vs 19:24:12 Temperature Measurement, Probe Number = 0, T = 20.201000 C 19:24:12 Temperature Measurement, Probe Number = 1, T = 20.057000 C 19:24:13 Temperature Measurement, Probe Number = 2, T = 20.061000 C 19:24:14 Temperature Measurement, Probe Number = 3, T = 20.016000 C 19:24:14 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:24:15 Temperature Measurement, Probe Number = 5, T = 20.013000 C 19:24:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:24:15 Integrated Voltage Measurement... 19:24:37 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = 0.000000922 V 19:24:37 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158383903 Vs 19:24:37 Integrated Voltage Measurement... 19:24:59 Voltage Offset Correction: v_off_ini = 0.000000095 V, v_off_fin = -0.000002283 V 19:24:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158363553 Vs 19:25:13 Temperature Measurement, Probe Number = 0, T = 20.190000 C 19:25:14 Temperature Measurement, Probe Number = 1, T = 20.057000 C 19:25:14 Temperature Measurement, Probe Number = 2, T = 20.061000 C 19:25:15 Temperature Measurement, Probe Number = 3, T = 20.015000 C 19:25:15 Temperature Measurement, Probe Number = 4, T = 20.035000 C 19:25:16 Temperature Measurement, Probe Number = 5, T = 20.012000 C 19:25:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 19:25:16 Integrated Voltage Measurement... 19:25:38 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000000468 V 19:25:38 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158384857 Vs 19:25:38 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000002210 V 19:26:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371225 Vs 19:26:14 Temperature Measurement, Probe Number = 0, T = 20.198000 C 19:26:15 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:26:15 Temperature Measurement, Probe Number = 2, T = 20.060000 C 19:26:16 Temperature Measurement, Probe Number = 3, T = 20.016000 C 19:26:16 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:26:17 Temperature Measurement, Probe Number = 5, T = 20.012000 C 19:26:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:26:17 Integrated Voltage Measurement... 19:26:39 Voltage Offset Correction: v_off_ini = -0.000001778 V, v_off_fin = -0.000001119 V 19:26:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158381392 Vs 19:26:40 Integrated Voltage Measurement... 19:27:02 Voltage Offset Correction: v_off_ini = -0.000000227 V, v_off_fin = -0.000002897 V 19:27:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367819 Vs 19:27:16 Temperature Measurement, Probe Number = 0, T = 20.185000 C 19:27:16 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:27:17 Temperature Measurement, Probe Number = 2, T = 20.059000 C 19:27:17 Temperature Measurement, Probe Number = 3, T = 20.015000 C 19:27:18 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:27:19 Temperature Measurement, Probe Number = 5, T = 20.013000 C 19:27:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:27:19 Integrated Voltage Measurement... 19:27:41 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = 0.000000614 V 19:27:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158370024 Vs 19:27:41 Integrated Voltage Measurement... 19:28:03 Voltage Offset Correction: v_off_ini = -0.000000124 V, v_off_fin = -0.000001792 V 19:28:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371675 Vs 19:28:17 Temperature Measurement, Probe Number = 0, T = 20.172000 C 19:28:17 Temperature Measurement, Probe Number = 1, T = 20.054000 C 19:28:18 Temperature Measurement, Probe Number = 2, T = 20.057000 C 19:28:18 Temperature Measurement, Probe Number = 3, T = 20.016000 C 19:28:19 Temperature Measurement, Probe Number = 4, T = 20.034000 C 19:28:20 Temperature Measurement, Probe Number = 5, T = 20.012000 C 19:28:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:28:20 Integrated Voltage Measurement... 19:28:42 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000002371 V 19:28:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158416069 Vs 19:28:42 Integrated Voltage Measurement... 19:29:04 Voltage Offset Correction: v_off_ini = -0.000001163 V, v_off_fin = -0.000003124 V 19:29:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361654 Vs 19:29:18 Temperature Measurement, Probe Number = 0, T = 20.158000 C 19:29:18 Temperature Measurement, Probe Number = 1, T = 20.053000 C 19:29:19 Temperature Measurement, Probe Number = 2, T = 20.058000 C 19:29:19 Temperature Measurement, Probe Number = 3, T = 20.016000 C 19:29:20 Temperature Measurement, Probe Number = 4, T = 20.033000 C 19:29:21 Temperature Measurement, Probe Number = 5, T = 20.014000 C 19:29:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 19:29:21 Integrated Voltage Measurement... 19:29:43 Voltage Offset Correction: v_off_ini = -0.000000490 V, v_off_fin = -0.000000944 V 19:29:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158375598 Vs 19:29:44 Integrated Voltage Measurement... 19:30:06 Voltage Offset Correction: v_off_ini = -0.000001653 V, v_off_fin = -0.000002334 V 19:30:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373929 Vs 20:26:20 Temperature Measurement, Probe Number = 0, T = 20.092000 C 20:26:21 Temperature Measurement, Probe Number = 1, T = 20.059000 C 20:26:21 Temperature Measurement, Probe Number = 2, T = 20.063000 C 20:26:22 Temperature Measurement, Probe Number = 3, T = 20.009000 C 20:26:22 Temperature Measurement, Probe Number = 4, T = 20.042000 C 20:26:23 Temperature Measurement, Probe Number = 5, T = 20.019000 C 20:26:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:26:23 Integrated Voltage Measurement... 20:26:45 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000000732 V 20:26:45 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158418038 Vs 20:26:45 Integrated Voltage Measurement... 20:27:07 Voltage Offset Correction: v_off_ini = -0.000002897 V, v_off_fin = -0.000001675 V 20:27:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158349326 Vs 20:27:21 Temperature Measurement, Probe Number = 0, T = 20.109000 C 20:27:22 Temperature Measurement, Probe Number = 1, T = 20.057000 C 20:27:22 Temperature Measurement, Probe Number = 2, T = 20.065000 C 20:27:23 Temperature Measurement, Probe Number = 3, T = 20.008000 C 20:27:24 Temperature Measurement, Probe Number = 4, T = 20.040000 C 20:27:24 Temperature Measurement, Probe Number = 5, T = 20.018000 C 20:27:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:27:24 Integrated Voltage Measurement... 20:27:46 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000002224 V 20:27:46 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158396853 Vs 20:27:46 Integrated Voltage Measurement... 20:28:09 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000002312 V 20:28:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371469 Vs 20:28:22 Temperature Measurement, Probe Number = 0, T = 20.076000 C 20:28:23 Temperature Measurement, Probe Number = 1, T = 20.060000 C 20:28:23 Temperature Measurement, Probe Number = 2, T = 20.066000 C 20:28:24 Temperature Measurement, Probe Number = 3, T = 20.010000 C 20:28:25 Temperature Measurement, Probe Number = 4, T = 20.040000 C 20:28:25 Temperature Measurement, Probe Number = 5, T = 20.017000 C 20:28:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:28:25 Integrated Voltage Measurement... 20:28:47 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000003051 V 20:28:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409378 Vs 20:28:47 Integrated Voltage Measurement... 20:29:10 Voltage Offset Correction: v_off_ini = 0.000001112 V, v_off_fin = -0.000002590 V 20:29:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384501 Vs 20:29:23 Temperature Measurement, Probe Number = 0, T = 20.071000 C 20:29:24 Temperature Measurement, Probe Number = 1, T = 20.060000 C 20:29:25 Temperature Measurement, Probe Number = 2, T = 20.065000 C 20:29:25 Temperature Measurement, Probe Number = 3, T = 20.009000 C 20:29:26 Temperature Measurement, Probe Number = 4, T = 20.041000 C 20:29:27 Temperature Measurement, Probe Number = 5, T = 20.018000 C 20:29:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:29:27 Integrated Voltage Measurement... 20:29:49 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000001434 V 20:29:49 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158386221 Vs 20:29:49 Integrated Voltage Measurement... 20:30:11 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000001793 V 20:30:12 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158358776 Vs 20:30:25 Temperature Measurement, Probe Number = 0, T = 20.113000 C 20:30:26 Temperature Measurement, Probe Number = 1, T = 20.062000 C 20:30:27 Temperature Measurement, Probe Number = 2, T = 20.064000 C 20:30:27 Temperature Measurement, Probe Number = 3, T = 20.011000 C 20:30:28 Temperature Measurement, Probe Number = 4, T = 20.040000 C 20:30:28 Temperature Measurement, Probe Number = 5, T = 20.019000 C 20:30:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:30:28 Integrated Voltage Measurement... 20:30:51 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000000849 V 20:30:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158382912 Vs 20:30:51 Integrated Voltage Measurement... 20:31:13 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000002597 V 20:31:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158358104 Vs 20:31:27 Temperature Measurement, Probe Number = 0, T = 20.126000 C 20:31:27 Temperature Measurement, Probe Number = 1, T = 20.062000 C 20:31:28 Temperature Measurement, Probe Number = 2, T = 20.065000 C 20:31:29 Temperature Measurement, Probe Number = 3, T = 20.007000 C 20:31:29 Temperature Measurement, Probe Number = 4, T = 20.041000 C 20:31:30 Temperature Measurement, Probe Number = 5, T = 20.020000 C 20:31:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:31:30 Integrated Voltage Measurement... 20:31:52 Voltage Offset Correction: v_off_ini = -0.000002575 V, v_off_fin = -0.000001639 V 20:31:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407138 Vs 20:31:52 Integrated Voltage Measurement... 20:32:15 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = -0.000002758 V 20:32:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369696 Vs 20:32:29 Temperature Measurement, Probe Number = 0, T = 20.110000 C 20:32:29 Temperature Measurement, Probe Number = 1, T = 20.061000 C 20:32:30 Temperature Measurement, Probe Number = 2, T = 20.065000 C 20:32:30 Temperature Measurement, Probe Number = 3, T = 20.008000 C 20:32:31 Temperature Measurement, Probe Number = 4, T = 20.040000 C 20:32:32 Temperature Measurement, Probe Number = 5, T = 20.019000 C 20:32:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:32:32 Integrated Voltage Measurement... 20:32:54 Voltage Offset Correction: v_off_ini = -0.000001499 V, v_off_fin = -0.000001229 V 20:32:54 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158390559 Vs 20:32:54 Integrated Voltage Measurement... 20:33:16 Voltage Offset Correction: v_off_ini = -0.000000680 V, v_off_fin = -0.000002758 V 20:33:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372830 Vs 20:33:30 Temperature Measurement, Probe Number = 0, T = 20.104000 C 20:33:31 Temperature Measurement, Probe Number = 1, T = 20.056000 C 20:33:31 Temperature Measurement, Probe Number = 2, T = 20.063000 C 20:33:32 Temperature Measurement, Probe Number = 3, T = 20.009000 C 20:33:32 Temperature Measurement, Probe Number = 4, T = 20.039000 C 20:33:33 Temperature Measurement, Probe Number = 5, T = 20.017000 C 20:33:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:33:33 Integrated Voltage Measurement... 20:33:55 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000000154 V 20:33:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158378726 Vs 20:33:56 Integrated Voltage Measurement... 20:34:18 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000001646 V 20:34:19 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158371975 Vs 20:34:32 Temperature Measurement, Probe Number = 0, T = 20.098000 C 20:34:33 Temperature Measurement, Probe Number = 1, T = 20.055000 C 20:34:33 Temperature Measurement, Probe Number = 2, T = 20.063000 C 20:34:34 Temperature Measurement, Probe Number = 3, T = 20.008000 C 20:34:35 Temperature Measurement, Probe Number = 4, T = 20.039000 C 20:34:35 Temperature Measurement, Probe Number = 5, T = 20.017000 C 20:34:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:34:35 Integrated Voltage Measurement... 20:34:57 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000002546 V 20:34:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417656 Vs 20:34:58 Integrated Voltage Measurement... 20:35:20 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000002919 V 20:35:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361234 Vs 20:35:34 Temperature Measurement, Probe Number = 0, T = 20.090000 C 20:35:34 Temperature Measurement, Probe Number = 1, T = 20.058000 C 20:35:35 Temperature Measurement, Probe Number = 2, T = 20.062000 C 20:35:36 Temperature Measurement, Probe Number = 3, T = 20.007000 C 20:35:36 Temperature Measurement, Probe Number = 4, T = 20.040000 C 20:35:37 Temperature Measurement, Probe Number = 5, T = 20.018000 C 20:35:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 20:35:37 Integrated Voltage Measurement... 20:35:59 Voltage Offset Correction: v_off_ini = -0.000002129 V, v_off_fin = -0.000001039 V 20:35:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403583 Vs 20:35:59 Integrated Voltage Measurement... 20:36:21 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000002817 V 20:36:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372310 Vs 21:32:35 Temperature Measurement, Probe Number = 0, T = 19.948000 C 21:32:36 Temperature Measurement, Probe Number = 1, T = 20.050000 C 21:32:36 Temperature Measurement, Probe Number = 2, T = 20.054000 C 21:32:37 Temperature Measurement, Probe Number = 3, T = 19.987000 C 21:32:37 Temperature Measurement, Probe Number = 4, T = 20.033000 C 21:32:38 Temperature Measurement, Probe Number = 5, T = 20.013000 C 21:32:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:32:38 Integrated Voltage Measurement... 21:33:00 Voltage Offset Correction: v_off_ini = -0.000002239 V, v_off_fin = -0.000002093 V 21:33:00 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158421969 Vs 21:33:00 Integrated Voltage Measurement... 21:33:22 Voltage Offset Correction: v_off_ini = 0.000001215 V, v_off_fin = -0.000002744 V 21:33:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389653 Vs 21:33:36 Temperature Measurement, Probe Number = 0, T = 19.944000 C 21:33:37 Temperature Measurement, Probe Number = 1, T = 20.053000 C 21:33:37 Temperature Measurement, Probe Number = 2, T = 20.055000 C 21:33:38 Temperature Measurement, Probe Number = 3, T = 19.988000 C 21:33:38 Temperature Measurement, Probe Number = 4, T = 20.035000 C 21:33:39 Temperature Measurement, Probe Number = 5, T = 20.013000 C 21:33:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 21:33:39 Integrated Voltage Measurement... 21:34:01 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = 0.000000263 V 21:34:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395109 Vs 21:34:02 Integrated Voltage Measurement... 21:34:24 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000002327 V 21:34:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380179 Vs 21:34:37 Temperature Measurement, Probe Number = 0, T = 19.975000 C 21:34:38 Temperature Measurement, Probe Number = 1, T = 20.057000 C 21:34:39 Temperature Measurement, Probe Number = 2, T = 20.057000 C 21:34:39 Temperature Measurement, Probe Number = 3, T = 19.989000 C 21:34:40 Temperature Measurement, Probe Number = 4, T = 20.035000 C 21:34:41 Temperature Measurement, Probe Number = 5, T = 20.017000 C 21:34:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 21:34:41 Integrated Voltage Measurement... 21:35:03 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001332 V 21:35:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158387407 Vs 21:35:03 Integrated Voltage Measurement... 21:35:25 Voltage Offset Correction: v_off_ini = -0.000000446 V, v_off_fin = -0.000003659 V 21:35:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158360960 Vs 21:35:38 Temperature Measurement, Probe Number = 0, T = 19.982000 C 21:35:39 Temperature Measurement, Probe Number = 1, T = 20.056000 C 21:35:40 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:35:40 Temperature Measurement, Probe Number = 3, T = 19.989000 C 21:35:41 Temperature Measurement, Probe Number = 4, T = 20.035000 C 21:35:41 Temperature Measurement, Probe Number = 5, T = 20.017000 C 21:35:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.02 21:35:41 Integrated Voltage Measurement... 21:36:04 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000000029 V 21:36:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398900 Vs 21:36:04 Integrated Voltage Measurement... 21:36:26 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002254 V 21:36:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369521 Vs 21:36:40 Temperature Measurement, Probe Number = 0, T = 19.966000 C 21:36:41 Temperature Measurement, Probe Number = 1, T = 20.052000 C 21:36:41 Temperature Measurement, Probe Number = 2, T = 20.054000 C 21:36:42 Temperature Measurement, Probe Number = 3, T = 19.988000 C 21:36:42 Temperature Measurement, Probe Number = 4, T = 20.034000 C 21:36:43 Temperature Measurement, Probe Number = 5, T = 20.014000 C 21:36:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:36:43 Integrated Voltage Measurement... 21:37:05 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = -0.000000263 V 21:37:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392584 Vs 21:37:05 Integrated Voltage Measurement... 21:37:28 Voltage Offset Correction: v_off_ini = -0.000000776 V, v_off_fin = -0.000002869 V 21:37:28 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158363097 Vs 21:37:41 Temperature Measurement, Probe Number = 0, T = 19.992000 C 21:37:42 Temperature Measurement, Probe Number = 1, T = 20.054000 C 21:37:42 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:37:43 Temperature Measurement, Probe Number = 3, T = 19.987000 C 21:37:44 Temperature Measurement, Probe Number = 4, T = 20.035000 C 21:37:44 Temperature Measurement, Probe Number = 5, T = 20.014000 C 21:37:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 20.01 21:37:44 Integrated Voltage Measurement... 21:38:06 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000001083 V 21:38:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158368433 Vs 21:38:06 Integrated Voltage Measurement... 21:38:29 Voltage Offset Correction: v_off_ini = 0.000000586 V, v_off_fin = -0.000002694 V 21:38:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389127 Vs 21:38:42 Temperature Measurement, Probe Number = 0, T = 19.994000 C 21:38:43 Temperature Measurement, Probe Number = 1, T = 20.055000 C 21:38:43 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:38:44 Temperature Measurement, Probe Number = 3, T = 19.989000 C 21:38:45 Temperature Measurement, Probe Number = 4, T = 20.034000 C 21:38:45 Temperature Measurement, Probe Number = 5, T = 20.014000 C 21:38:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:38:45 Integrated Voltage Measurement... 21:39:07 Voltage Offset Correction: v_off_ini = -0.000001815 V, v_off_fin = -0.000001756 V 21:39:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393103 Vs 21:39:08 Integrated Voltage Measurement... 21:39:30 Voltage Offset Correction: v_off_ini = -0.000000176 V, v_off_fin = -0.000002188 V 21:39:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158367378 Vs 21:39:44 Temperature Measurement, Probe Number = 0, T = 19.971000 C 21:39:44 Temperature Measurement, Probe Number = 1, T = 20.050000 C 21:39:45 Temperature Measurement, Probe Number = 2, T = 20.055000 C 21:39:45 Temperature Measurement, Probe Number = 3, T = 19.984000 C 21:39:46 Temperature Measurement, Probe Number = 4, T = 20.032000 C 21:39:47 Temperature Measurement, Probe Number = 5, T = 20.014000 C 21:39:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:39:47 Integrated Voltage Measurement... 21:40:09 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000695 V 21:40:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158388304 Vs 21:40:09 Integrated Voltage Measurement... 21:40:31 Voltage Offset Correction: v_off_ini = -0.000000681 V, v_off_fin = -0.000001493 V 21:40:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158370528 Vs 21:40:45 Temperature Measurement, Probe Number = 0, T = 19.948000 C 21:40:46 Temperature Measurement, Probe Number = 1, T = 20.053000 C 21:40:46 Temperature Measurement, Probe Number = 2, T = 20.058000 C 21:40:47 Temperature Measurement, Probe Number = 3, T = 19.984000 C 21:40:47 Temperature Measurement, Probe Number = 4, T = 20.032000 C 21:40:48 Temperature Measurement, Probe Number = 5, T = 20.013000 C 21:40:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:40:48 Integrated Voltage Measurement... 21:41:10 Voltage Offset Correction: v_off_ini = -0.000002349 V, v_off_fin = -0.000001932 V 21:41:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158390135 Vs 21:41:10 Integrated Voltage Measurement... 21:41:33 Voltage Offset Correction: v_off_ini = 0.000001025 V, v_off_fin = -0.000001383 V 21:41:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393419 Vs 21:41:46 Temperature Measurement, Probe Number = 0, T = 19.935000 C 21:41:47 Temperature Measurement, Probe Number = 1, T = 20.056000 C 21:41:48 Temperature Measurement, Probe Number = 2, T = 20.058000 C 21:41:48 Temperature Measurement, Probe Number = 3, T = 19.986000 C 21:41:49 Temperature Measurement, Probe Number = 4, T = 20.032000 C 21:41:49 Temperature Measurement, Probe Number = 5, T = 20.014000 C 21:41:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.03 P6 = Top_Jaw, Value = 20.01 21:41:49 Integrated Voltage Measurement... 21:42:12 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000000768 V 21:42:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399934 Vs 21:42:12 Integrated Voltage Measurement... 21:42:34 Voltage Offset Correction: v_off_ini = 0.000002165 V, v_off_fin = -0.000001639 V 21:42:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394731 Vs 22:38:47 Temperature Measurement, Probe Number = 0, T = 19.879000 C 22:38:48 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:38:48 Temperature Measurement, Probe Number = 2, T = 20.037000 C 22:38:49 Temperature Measurement, Probe Number = 3, T = 19.959000 C 22:38:50 Temperature Measurement, Probe Number = 4, T = 20.017000 C 22:38:50 Temperature Measurement, Probe Number = 5, T = 20.002000 C 22:38:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:38:50 Integrated Voltage Measurement... 22:39:13 Voltage Offset Correction: v_off_ini = -0.000001391 V, v_off_fin = 0.000000315 V 22:39:13 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158400800 Vs 22:39:13 Integrated Voltage Measurement... 22:39:35 Voltage Offset Correction: v_off_ini = -0.000002467 V, v_off_fin = -0.000002958 V 22:39:35 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158356924 Vs 22:39:49 Temperature Measurement, Probe Number = 0, T = 19.873000 C 22:39:50 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:39:50 Temperature Measurement, Probe Number = 2, T = 20.039000 C 22:39:51 Temperature Measurement, Probe Number = 3, T = 19.959000 C 22:39:51 Temperature Measurement, Probe Number = 4, T = 20.017000 C 22:39:52 Temperature Measurement, Probe Number = 5, T = 20.003000 C 22:39:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:39:52 Integrated Voltage Measurement... 22:40:14 Voltage Offset Correction: v_off_ini = -0.000000637 V, v_off_fin = -0.000000703 V 22:40:14 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158393160 Vs 22:40:14 Integrated Voltage Measurement... 22:40:36 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000001940 V 22:40:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373769 Vs 22:40:50 Temperature Measurement, Probe Number = 0, T = 19.888000 C 22:40:51 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:40:51 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:40:52 Temperature Measurement, Probe Number = 3, T = 19.960000 C 22:40:52 Temperature Measurement, Probe Number = 4, T = 20.018000 C 22:40:53 Temperature Measurement, Probe Number = 5, T = 20.002000 C 22:40:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:40:53 Integrated Voltage Measurement... 22:41:15 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000000234 V 22:41:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392645 Vs 22:41:15 Integrated Voltage Measurement... 22:41:38 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000002123 V 22:41:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396438 Vs 22:41:51 Temperature Measurement, Probe Number = 0, T = 19.892000 C 22:41:52 Temperature Measurement, Probe Number = 1, T = 20.038000 C 22:41:52 Temperature Measurement, Probe Number = 2, T = 20.039000 C 22:41:53 Temperature Measurement, Probe Number = 3, T = 19.960000 C 22:41:54 Temperature Measurement, Probe Number = 4, T = 20.016000 C 22:41:54 Temperature Measurement, Probe Number = 5, T = 20.002000 C 22:41:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:41:54 Integrated Voltage Measurement... 22:42:17 Voltage Offset Correction: v_off_ini = -0.000000952 V, v_off_fin = -0.000002226 V 22:42:17 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403482 Vs 22:42:17 Integrated Voltage Measurement... 22:42:39 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = -0.000001179 V 22:42:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381302 Vs 22:42:53 Temperature Measurement, Probe Number = 0, T = 19.887000 C 22:42:53 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:42:54 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:42:54 Temperature Measurement, Probe Number = 3, T = 19.959000 C 22:42:55 Temperature Measurement, Probe Number = 4, T = 20.016000 C 22:42:56 Temperature Measurement, Probe Number = 5, T = 20.000000 C 22:42:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:42:56 Integrated Voltage Measurement... 22:43:18 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000001289 V 22:43:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158419391 Vs 22:43:18 Integrated Voltage Measurement... 22:43:40 Voltage Offset Correction: v_off_ini = -0.000000505 V, v_off_fin = -0.000002262 V 22:43:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388918 Vs 22:43:54 Temperature Measurement, Probe Number = 0, T = 19.886000 C 22:43:54 Temperature Measurement, Probe Number = 1, T = 20.042000 C 22:43:55 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:43:56 Temperature Measurement, Probe Number = 3, T = 19.958000 C 22:43:56 Temperature Measurement, Probe Number = 4, T = 20.015000 C 22:43:57 Temperature Measurement, Probe Number = 5, T = 20.001000 C 22:43:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:43:57 Integrated Voltage Measurement... 22:44:19 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000001486 V 22:44:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395085 Vs 22:44:19 Integrated Voltage Measurement... 22:44:41 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = -0.000002232 V 22:44:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386967 Vs 22:44:55 Temperature Measurement, Probe Number = 0, T = 19.888000 C 22:44:55 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:44:56 Temperature Measurement, Probe Number = 2, T = 20.041000 C 22:44:57 Temperature Measurement, Probe Number = 3, T = 19.957000 C 22:44:57 Temperature Measurement, Probe Number = 4, T = 20.015000 C 22:44:58 Temperature Measurement, Probe Number = 5, T = 20.001000 C 22:44:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:44:58 Integrated Voltage Measurement... 22:45:20 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = -0.000000622 V 22:45:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392693 Vs 22:45:20 Integrated Voltage Measurement... 22:45:42 Voltage Offset Correction: v_off_ini = 0.000001003 V, v_off_fin = -0.000002628 V 22:45:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389386 Vs 22:45:56 Temperature Measurement, Probe Number = 0, T = 19.902000 C 22:45:57 Temperature Measurement, Probe Number = 1, T = 20.038000 C 22:45:57 Temperature Measurement, Probe Number = 2, T = 20.039000 C 22:45:58 Temperature Measurement, Probe Number = 3, T = 19.959000 C 22:45:58 Temperature Measurement, Probe Number = 4, T = 20.015000 C 22:45:59 Temperature Measurement, Probe Number = 5, T = 19.999000 C 22:45:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:45:59 Integrated Voltage Measurement... 22:46:21 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = 0.000000146 V 22:46:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158388253 Vs 22:46:21 Integrated Voltage Measurement... 22:46:43 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = -0.000002613 V 22:46:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399255 Vs 22:46:57 Temperature Measurement, Probe Number = 0, T = 19.909000 C 22:46:58 Temperature Measurement, Probe Number = 1, T = 20.039000 C 22:46:58 Temperature Measurement, Probe Number = 2, T = 20.038000 C 22:46:59 Temperature Measurement, Probe Number = 3, T = 19.956000 C 22:47:00 Temperature Measurement, Probe Number = 4, T = 20.016000 C 22:47:00 Temperature Measurement, Probe Number = 5, T = 20.001000 C 22:47:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:47:00 Integrated Voltage Measurement... 22:47:22 Voltage Offset Correction: v_off_ini = -0.000000329 V, v_off_fin = 0.000000959 V 22:47:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158382446 Vs 22:47:22 Integrated Voltage Measurement... 22:47:45 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000001610 V 22:47:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389076 Vs 22:47:58 Temperature Measurement, Probe Number = 0, T = 19.947000 C 22:47:59 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:48:00 Temperature Measurement, Probe Number = 2, T = 20.035000 C 22:48:00 Temperature Measurement, Probe Number = 3, T = 19.955000 C 22:48:01 Temperature Measurement, Probe Number = 4, T = 20.016000 C 22:48:02 Temperature Measurement, Probe Number = 5, T = 20.001000 C 22:48:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 22:48:02 Integrated Voltage Measurement... 22:48:24 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000812 V 22:48:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158402622 Vs 22:48:24 Integrated Voltage Measurement... 22:48:46 Voltage Offset Correction: v_off_ini = 0.000002554 V, v_off_fin = -0.000002188 V 22:48:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417287 Vs 23:45:00 Temperature Measurement, Probe Number = 0, T = 19.982000 C 23:45:00 Temperature Measurement, Probe Number = 1, T = 20.035000 C 23:45:01 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:45:02 Temperature Measurement, Probe Number = 3, T = 19.947000 C 23:45:02 Temperature Measurement, Probe Number = 4, T = 20.003000 C 23:45:03 Temperature Measurement, Probe Number = 5, T = 19.994000 C 23:45:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:45:03 Integrated Voltage Measurement... 23:45:25 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000001083 V 23:45:25 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158430873 Vs 23:45:25 Integrated Voltage Measurement... 23:45:47 Voltage Offset Correction: v_off_ini = 0.000000402 V, v_off_fin = -0.000001207 V 23:45:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383242 Vs 23:46:01 Temperature Measurement, Probe Number = 0, T = 19.967000 C 23:46:01 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:46:02 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:46:03 Temperature Measurement, Probe Number = 3, T = 19.947000 C 23:46:03 Temperature Measurement, Probe Number = 4, T = 20.002000 C 23:46:04 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:46:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:46:04 Integrated Voltage Measurement... 23:46:26 Voltage Offset Correction: v_off_ini = -0.000002459 V, v_off_fin = -0.000001983 V 23:46:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410487 Vs 23:46:26 Integrated Voltage Measurement... 23:46:48 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = -0.000002459 V 23:46:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391956 Vs 23:47:02 Temperature Measurement, Probe Number = 0, T = 19.944000 C 23:47:02 Temperature Measurement, Probe Number = 1, T = 20.035000 C 23:47:03 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:47:04 Temperature Measurement, Probe Number = 3, T = 19.946000 C 23:47:04 Temperature Measurement, Probe Number = 4, T = 20.002000 C 23:47:05 Temperature Measurement, Probe Number = 5, T = 19.994000 C 23:47:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:47:05 Integrated Voltage Measurement... 23:47:27 Voltage Offset Correction: v_off_ini = -0.000002751 V, v_off_fin = -0.000001990 V 23:47:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415765 Vs 23:47:27 Integrated Voltage Measurement... 23:47:49 Voltage Offset Correction: v_off_ini = -0.000002370 V, v_off_fin = -0.000002978 V 23:47:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158368774 Vs 23:48:03 Temperature Measurement, Probe Number = 0, T = 19.924000 C 23:48:04 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:48:04 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:48:05 Temperature Measurement, Probe Number = 3, T = 19.944000 C 23:48:06 Temperature Measurement, Probe Number = 4, T = 20.002000 C 23:48:06 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:48:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:48:06 Integrated Voltage Measurement... 23:48:29 Voltage Offset Correction: v_off_ini = -0.000001858 V, v_off_fin = -0.000001119 V 23:48:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395998 Vs 23:48:29 Integrated Voltage Measurement... 23:48:51 Voltage Offset Correction: v_off_ini = -0.000000154 V, v_off_fin = -0.000002239 V 23:48:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384839 Vs 23:49:05 Temperature Measurement, Probe Number = 0, T = 19.920000 C 23:49:06 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:49:06 Temperature Measurement, Probe Number = 2, T = 20.025000 C 23:49:07 Temperature Measurement, Probe Number = 3, T = 19.944000 C 23:49:08 Temperature Measurement, Probe Number = 4, T = 20.001000 C 23:49:08 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:49:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:49:08 Integrated Voltage Measurement... 23:49:30 Voltage Offset Correction: v_off_ini = -0.000001873 V, v_off_fin = -0.000002795 V 23:49:31 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158426798 Vs 23:49:31 Integrated Voltage Measurement... 23:49:53 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = -0.000004361 V 23:49:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158361370 Vs 23:50:07 Temperature Measurement, Probe Number = 0, T = 19.913000 C 23:50:07 Temperature Measurement, Probe Number = 1, T = 20.031000 C 23:50:08 Temperature Measurement, Probe Number = 2, T = 20.025000 C 23:50:08 Temperature Measurement, Probe Number = 3, T = 19.943000 C 23:50:09 Temperature Measurement, Probe Number = 4, T = 20.001000 C 23:50:10 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:50:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:50:10 Integrated Voltage Measurement... 23:50:32 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000724 V 23:50:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158406583 Vs 23:50:32 Integrated Voltage Measurement... 23:50:54 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000001968 V 23:50:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378557 Vs 23:51:08 Temperature Measurement, Probe Number = 0, T = 19.926000 C 23:51:08 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:51:09 Temperature Measurement, Probe Number = 2, T = 20.023000 C 23:51:10 Temperature Measurement, Probe Number = 3, T = 19.944000 C 23:51:10 Temperature Measurement, Probe Number = 4, T = 20.002000 C 23:51:11 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:51:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:51:11 Integrated Voltage Measurement... 23:51:33 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000001317 V 23:51:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402465 Vs 23:51:34 Integrated Voltage Measurement... 23:51:59 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000001799 V 23:52:00 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158365226 Vs 23:52:13 Temperature Measurement, Probe Number = 0, T = 19.896000 C 23:52:14 Temperature Measurement, Probe Number = 1, T = 20.030000 C 23:52:14 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:52:15 Temperature Measurement, Probe Number = 3, T = 19.945000 C 23:52:16 Temperature Measurement, Probe Number = 4, T = 20.000000 C 23:52:16 Temperature Measurement, Probe Number = 5, T = 19.992000 C 23:52:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:52:16 Integrated Voltage Measurement... 23:52:38 Voltage Offset Correction: v_off_ini = -0.000001419 V, v_off_fin = -0.000001961 V 23:52:39 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158385945 Vs 23:52:39 Integrated Voltage Measurement... 23:53:01 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000001697 V 23:53:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378279 Vs 23:53:15 Temperature Measurement, Probe Number = 0, T = 19.911000 C 23:53:15 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:53:16 Temperature Measurement, Probe Number = 2, T = 20.025000 C 23:53:16 Temperature Measurement, Probe Number = 3, T = 19.945000 C 23:53:17 Temperature Measurement, Probe Number = 4, T = 19.999000 C 23:53:18 Temperature Measurement, Probe Number = 5, T = 19.992000 C 23:53:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:53:18 Integrated Voltage Measurement... 23:53:40 Voltage Offset Correction: v_off_ini = -0.000001843 V, v_off_fin = -0.000000958 V 23:53:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158404938 Vs 23:53:40 Integrated Voltage Measurement... 23:54:02 Voltage Offset Correction: v_off_ini = 0.000000936 V, v_off_fin = -0.000002816 V 23:54:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395928 Vs 23:54:16 Temperature Measurement, Probe Number = 0, T = 19.936000 C 23:54:16 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:54:17 Temperature Measurement, Probe Number = 2, T = 20.024000 C 23:54:18 Temperature Measurement, Probe Number = 3, T = 19.944000 C 23:54:18 Temperature Measurement, Probe Number = 4, T = 19.999000 C 23:54:19 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:54:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.99 23:54:19 Integrated Voltage Measurement... 23:54:41 Voltage Offset Correction: v_off_ini = -0.000001814 V, v_off_fin = -0.000001024 V 23:54:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402919 Vs 23:54:41 Integrated Voltage Measurement... 23:55:03 Voltage Offset Correction: v_off_ini = -0.000000841 V, v_off_fin = -0.000002084 V 23:55:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158371316 Vs 00:51:17 Temperature Measurement, Probe Number = 0, T = 19.867000 C 00:51:17 Temperature Measurement, Probe Number = 1, T = 20.019000 C 00:51:18 Temperature Measurement, Probe Number = 2, T = 20.007000 C 00:51:19 Temperature Measurement, Probe Number = 3, T = 19.922000 C 00:51:19 Temperature Measurement, Probe Number = 4, T = 19.983000 C 00:51:20 Temperature Measurement, Probe Number = 5, T = 19.983000 C 00:51:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:51:20 Integrated Voltage Measurement... 00:51:42 Voltage Offset Correction: v_off_ini = 0.000000176 V, v_off_fin = -0.000003452 V 00:51:42 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158441239 Vs 00:51:42 Integrated Voltage Measurement... 00:52:04 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = -0.000002085 V 00:52:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386730 Vs 00:52:18 Temperature Measurement, Probe Number = 0, T = 19.860000 C 00:52:19 Temperature Measurement, Probe Number = 1, T = 20.021000 C 00:52:19 Temperature Measurement, Probe Number = 2, T = 20.010000 C 00:52:20 Temperature Measurement, Probe Number = 3, T = 19.921000 C 00:52:20 Temperature Measurement, Probe Number = 4, T = 19.984000 C 00:52:21 Temperature Measurement, Probe Number = 5, T = 19.982000 C 00:52:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:52:21 Integrated Voltage Measurement... 00:52:43 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000002604 V 00:52:43 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422012 Vs 00:52:43 Integrated Voltage Measurement... 00:53:05 Voltage Offset Correction: v_off_ini = -0.000000278 V, v_off_fin = -0.000002253 V 00:53:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386870 Vs 00:53:19 Temperature Measurement, Probe Number = 0, T = 19.884000 C 00:53:20 Temperature Measurement, Probe Number = 1, T = 20.022000 C 00:53:20 Temperature Measurement, Probe Number = 2, T = 20.008000 C 00:53:21 Temperature Measurement, Probe Number = 3, T = 19.922000 C 00:53:22 Temperature Measurement, Probe Number = 4, T = 19.983000 C 00:53:22 Temperature Measurement, Probe Number = 5, T = 19.982000 C 00:53:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:53:22 Integrated Voltage Measurement... 00:53:44 Voltage Offset Correction: v_off_ini = -0.000001814 V, v_off_fin = -0.000000702 V 00:53:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414634 Vs 00:53:45 Integrated Voltage Measurement... 00:54:07 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = -0.000002019 V 00:54:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380553 Vs 00:54:20 Temperature Measurement, Probe Number = 0, T = 19.871000 C 00:54:21 Temperature Measurement, Probe Number = 1, T = 20.022000 C 00:54:22 Temperature Measurement, Probe Number = 2, T = 20.007000 C 00:54:22 Temperature Measurement, Probe Number = 3, T = 19.921000 C 00:54:23 Temperature Measurement, Probe Number = 4, T = 19.983000 C 00:54:23 Temperature Measurement, Probe Number = 5, T = 19.982000 C 00:54:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:54:23 Integrated Voltage Measurement... 00:54:46 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000001784 V 00:54:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158419417 Vs 00:54:46 Integrated Voltage Measurement... 00:55:08 Voltage Offset Correction: v_off_ini = -0.000000914 V, v_off_fin = -0.000002019 V 00:55:09 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158383213 Vs 00:55:22 Temperature Measurement, Probe Number = 0, T = 19.857000 C 00:55:23 Temperature Measurement, Probe Number = 1, T = 20.022000 C 00:55:23 Temperature Measurement, Probe Number = 2, T = 20.009000 C 00:55:24 Temperature Measurement, Probe Number = 3, T = 19.921000 C 00:55:25 Temperature Measurement, Probe Number = 4, T = 19.983000 C 00:55:25 Temperature Measurement, Probe Number = 5, T = 19.981000 C 00:55:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:55:25 Integrated Voltage Measurement... 00:55:49 Voltage Offset Correction: v_off_ini = -0.000001909 V, v_off_fin = -0.000000366 V 00:55:49 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158407019 Vs 00:55:49 Integrated Voltage Measurement... 00:56:12 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = 0.000000432 V 00:56:12 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158377979 Vs 00:56:25 Temperature Measurement, Probe Number = 0, T = 19.851000 C 00:56:26 Temperature Measurement, Probe Number = 1, T = 20.021000 C 00:56:26 Temperature Measurement, Probe Number = 2, T = 20.006000 C 00:56:27 Temperature Measurement, Probe Number = 3, T = 19.919000 C 00:56:28 Temperature Measurement, Probe Number = 4, T = 19.982000 C 00:56:28 Temperature Measurement, Probe Number = 5, T = 19.980000 C 00:56:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:56:28 Integrated Voltage Measurement... 00:56:51 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000002531 V 00:56:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158406479 Vs 00:56:51 Integrated Voltage Measurement... 00:57:13 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000002465 V 00:57:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390247 Vs 00:57:27 Temperature Measurement, Probe Number = 0, T = 19.826000 C 00:57:27 Temperature Measurement, Probe Number = 1, T = 20.019000 C 00:57:28 Temperature Measurement, Probe Number = 2, T = 20.004000 C 00:57:29 Temperature Measurement, Probe Number = 3, T = 19.918000 C 00:57:29 Temperature Measurement, Probe Number = 4, T = 19.982000 C 00:57:30 Temperature Measurement, Probe Number = 5, T = 19.980000 C 00:57:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.83 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:57:30 Integrated Voltage Measurement... 00:57:52 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = -0.000001024 V 00:57:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158394416 Vs 00:57:52 Integrated Voltage Measurement... 00:58:15 Voltage Offset Correction: v_off_ini = 0.000000688 V, v_off_fin = -0.000002670 V 00:58:15 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158405907 Vs 00:58:29 Temperature Measurement, Probe Number = 0, T = 19.818000 C 00:58:29 Temperature Measurement, Probe Number = 1, T = 20.017000 C 00:58:30 Temperature Measurement, Probe Number = 2, T = 20.003000 C 00:58:31 Temperature Measurement, Probe Number = 3, T = 19.916000 C 00:58:31 Temperature Measurement, Probe Number = 4, T = 19.980000 C 00:58:32 Temperature Measurement, Probe Number = 5, T = 19.980000 C 00:58:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:58:32 Integrated Voltage Measurement... 00:58:54 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000000380 V 00:58:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158415329 Vs 00:58:54 Integrated Voltage Measurement... 00:59:17 Voltage Offset Correction: v_off_ini = -0.000000563 V, v_off_fin = -0.000002385 V 00:59:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388924 Vs 00:59:30 Temperature Measurement, Probe Number = 0, T = 19.777000 C 00:59:31 Temperature Measurement, Probe Number = 1, T = 20.017000 C 00:59:31 Temperature Measurement, Probe Number = 2, T = 20.002000 C 00:59:32 Temperature Measurement, Probe Number = 3, T = 19.917000 C 00:59:33 Temperature Measurement, Probe Number = 4, T = 19.978000 C 00:59:33 Temperature Measurement, Probe Number = 5, T = 19.979000 C 00:59:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.78 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 00:59:33 Integrated Voltage Measurement... 00:59:56 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000000980 V 00:59:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403669 Vs 00:59:56 Integrated Voltage Measurement... 01:00:18 Voltage Offset Correction: v_off_ini = -0.000002056 V, v_off_fin = -0.000003394 V 01:00:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372238 Vs 01:00:32 Temperature Measurement, Probe Number = 0, T = 19.776000 C 01:00:33 Temperature Measurement, Probe Number = 1, T = 20.019000 C 01:00:33 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:00:34 Temperature Measurement, Probe Number = 3, T = 19.916000 C 01:00:34 Temperature Measurement, Probe Number = 4, T = 19.979000 C 01:00:35 Temperature Measurement, Probe Number = 5, T = 19.978000 C 01:00:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.78 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.92 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.98 01:00:35 Integrated Voltage Measurement... 01:00:57 Voltage Offset Correction: v_off_ini = -0.000002048 V, v_off_fin = -0.000001902 V 01:00:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415890 Vs 01:00:57 Integrated Voltage Measurement... 01:01:20 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001199 V 01:01:20 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158384605 Vs 01:57:33 Temperature Measurement, Probe Number = 0, T = 19.705000 C 01:57:34 Temperature Measurement, Probe Number = 1, T = 19.989000 C 01:57:35 Temperature Measurement, Probe Number = 2, T = 19.972000 C 01:57:35 Temperature Measurement, Probe Number = 3, T = 19.884000 C 01:57:36 Temperature Measurement, Probe Number = 4, T = 19.954000 C 01:57:36 Temperature Measurement, Probe Number = 5, T = 19.959000 C 01:57:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.70 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 01:57:36 Integrated Voltage Measurement... 01:57:59 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001236 V 01:57:59 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158438250 Vs 01:57:59 Integrated Voltage Measurement... 01:58:21 Voltage Offset Correction: v_off_ini = -0.000001280 V, v_off_fin = -0.000003270 V 01:58:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391827 Vs 01:58:35 Temperature Measurement, Probe Number = 0, T = 19.689000 C 01:58:35 Temperature Measurement, Probe Number = 1, T = 19.996000 C 01:58:36 Temperature Measurement, Probe Number = 2, T = 19.976000 C 01:58:37 Temperature Measurement, Probe Number = 3, T = 19.884000 C 01:58:37 Temperature Measurement, Probe Number = 4, T = 19.956000 C 01:58:38 Temperature Measurement, Probe Number = 5, T = 19.959000 C 01:58:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 01:58:38 Integrated Voltage Measurement... 01:59:00 Voltage Offset Correction: v_off_ini = -0.000002004 V, v_off_fin = -0.000000980 V 01:59:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410125 Vs 01:59:01 Integrated Voltage Measurement... 01:59:23 Voltage Offset Correction: v_off_ini = -0.000000629 V, v_off_fin = -0.000002428 V 01:59:23 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158381928 Vs 01:59:36 Temperature Measurement, Probe Number = 0, T = 19.681000 C 01:59:37 Temperature Measurement, Probe Number = 1, T = 19.992000 C 01:59:37 Temperature Measurement, Probe Number = 2, T = 19.976000 C 01:59:38 Temperature Measurement, Probe Number = 3, T = 19.883000 C 01:59:39 Temperature Measurement, Probe Number = 4, T = 19.955000 C 01:59:39 Temperature Measurement, Probe Number = 5, T = 19.959000 C 01:59:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 01:59:39 Integrated Voltage Measurement... 02:00:01 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000002897 V 02:00:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158431031 Vs 02:00:01 Integrated Voltage Measurement... 02:00:24 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000001945 V 02:00:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389834 Vs 02:00:38 Temperature Measurement, Probe Number = 0, T = 19.671000 C 02:00:38 Temperature Measurement, Probe Number = 1, T = 19.993000 C 02:00:39 Temperature Measurement, Probe Number = 2, T = 19.976000 C 02:00:40 Temperature Measurement, Probe Number = 3, T = 19.883000 C 02:00:40 Temperature Measurement, Probe Number = 4, T = 19.954000 C 02:00:41 Temperature Measurement, Probe Number = 5, T = 19.956000 C 02:00:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.67 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 02:00:41 Integrated Voltage Measurement... 02:01:03 Voltage Offset Correction: v_off_ini = -0.000002677 V, v_off_fin = -0.000000205 V 02:01:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424113 Vs 02:01:03 Integrated Voltage Measurement... 02:01:25 Voltage Offset Correction: v_off_ini = -0.000000410 V, v_off_fin = -0.000002421 V 02:01:25 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158388616 Vs 02:01:39 Temperature Measurement, Probe Number = 0, T = 19.651000 C 02:01:39 Temperature Measurement, Probe Number = 1, T = 19.993000 C 02:01:40 Temperature Measurement, Probe Number = 2, T = 19.978000 C 02:01:41 Temperature Measurement, Probe Number = 3, T = 19.881000 C 02:01:41 Temperature Measurement, Probe Number = 4, T = 19.952000 C 02:01:42 Temperature Measurement, Probe Number = 5, T = 19.956000 C 02:01:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.65 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 02:01:42 Integrated Voltage Measurement... 02:02:04 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000000534 V 02:02:04 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158415580 Vs 02:02:04 Integrated Voltage Measurement... 02:02:26 Voltage Offset Correction: v_off_ini = -0.000001638 V, v_off_fin = -0.000003811 V 02:02:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388416 Vs 02:02:40 Temperature Measurement, Probe Number = 0, T = 19.643000 C 02:02:41 Temperature Measurement, Probe Number = 1, T = 19.991000 C 02:02:41 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:02:42 Temperature Measurement, Probe Number = 3, T = 19.881000 C 02:02:42 Temperature Measurement, Probe Number = 4, T = 19.953000 C 02:02:43 Temperature Measurement, Probe Number = 5, T = 19.956000 C 02:02:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 02:02:43 Integrated Voltage Measurement... 02:03:05 Voltage Offset Correction: v_off_ini = -0.000002063 V, v_off_fin = -0.000001317 V 02:03:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424297 Vs 02:03:05 Integrated Voltage Measurement... 02:03:27 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000003818 V 02:03:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398110 Vs 02:03:41 Temperature Measurement, Probe Number = 0, T = 19.634000 C 02:03:42 Temperature Measurement, Probe Number = 1, T = 19.989000 C 02:03:43 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:03:43 Temperature Measurement, Probe Number = 3, T = 19.879000 C 02:03:44 Temperature Measurement, Probe Number = 4, T = 19.952000 C 02:03:44 Temperature Measurement, Probe Number = 5, T = 19.954000 C 02:03:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 02:03:44 Integrated Voltage Measurement... 02:04:07 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000001200 V 02:04:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418578 Vs 02:04:07 Integrated Voltage Measurement... 02:04:29 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000002838 V 02:04:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396605 Vs 02:04:43 Temperature Measurement, Probe Number = 0, T = 19.632000 C 02:04:43 Temperature Measurement, Probe Number = 1, T = 19.987000 C 02:04:44 Temperature Measurement, Probe Number = 2, T = 19.972000 C 02:04:45 Temperature Measurement, Probe Number = 3, T = 19.879000 C 02:04:45 Temperature Measurement, Probe Number = 4, T = 19.952000 C 02:04:46 Temperature Measurement, Probe Number = 5, T = 19.954000 C 02:04:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 02:04:46 Integrated Voltage Measurement... 02:05:08 Voltage Offset Correction: v_off_ini = -0.000002063 V, v_off_fin = -0.000000541 V 02:05:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158408045 Vs 02:05:08 Integrated Voltage Measurement... 02:05:30 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000003636 V 02:05:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398486 Vs 02:05:44 Temperature Measurement, Probe Number = 0, T = 19.633000 C 02:05:44 Temperature Measurement, Probe Number = 1, T = 19.990000 C 02:05:45 Temperature Measurement, Probe Number = 2, T = 19.973000 C 02:05:46 Temperature Measurement, Probe Number = 3, T = 19.878000 C 02:05:46 Temperature Measurement, Probe Number = 4, T = 19.952000 C 02:05:47 Temperature Measurement, Probe Number = 5, T = 19.956000 C 02:05:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.96 02:05:47 Integrated Voltage Measurement... 02:06:09 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000001054 V 02:06:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158412574 Vs 02:06:09 Integrated Voltage Measurement... 02:06:31 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000002261 V 02:06:31 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158387266 Vs 02:06:45 Temperature Measurement, Probe Number = 0, T = 19.619000 C 02:06:45 Temperature Measurement, Probe Number = 1, T = 19.989000 C 02:06:46 Temperature Measurement, Probe Number = 2, T = 19.974000 C 02:06:47 Temperature Measurement, Probe Number = 3, T = 19.877000 C 02:06:47 Temperature Measurement, Probe Number = 4, T = 19.949000 C 02:06:48 Temperature Measurement, Probe Number = 5, T = 19.954000 C 02:06:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 02:06:48 Integrated Voltage Measurement... 02:07:10 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000000951 V 02:07:10 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158419125 Vs 02:07:10 Integrated Voltage Measurement... 02:07:32 Voltage Offset Correction: v_off_ini = 0.000000454 V, v_off_fin = -0.000001829 V 02:07:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400608 Vs 03:03:46 Temperature Measurement, Probe Number = 0, T = 19.633000 C 03:03:46 Temperature Measurement, Probe Number = 1, T = 19.971000 C 03:03:47 Temperature Measurement, Probe Number = 2, T = 19.947000 C 03:03:48 Temperature Measurement, Probe Number = 3, T = 19.847000 C 03:03:48 Temperature Measurement, Probe Number = 4, T = 19.923000 C 03:03:49 Temperature Measurement, Probe Number = 5, T = 19.934000 C 03:03:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:03:49 Integrated Voltage Measurement... 03:04:11 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000000168 V 03:04:11 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158438662 Vs 03:04:11 Integrated Voltage Measurement... 03:04:34 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000001682 V 03:04:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381001 Vs 03:04:47 Temperature Measurement, Probe Number = 0, T = 19.602000 C 03:04:48 Temperature Measurement, Probe Number = 1, T = 19.966000 C 03:04:48 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:04:49 Temperature Measurement, Probe Number = 3, T = 19.843000 C 03:04:50 Temperature Measurement, Probe Number = 4, T = 19.922000 C 03:04:50 Temperature Measurement, Probe Number = 5, T = 19.934000 C 03:04:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:04:50 Integrated Voltage Measurement... 03:05:12 Voltage Offset Correction: v_off_ini = -0.000002195 V, v_off_fin = 0.000000073 V 03:05:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410187 Vs 03:05:12 Integrated Voltage Measurement... 03:05:35 Voltage Offset Correction: v_off_ini = -0.000000285 V, v_off_fin = -0.000003314 V 03:05:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403616 Vs 03:05:48 Temperature Measurement, Probe Number = 0, T = 19.584000 C 03:05:49 Temperature Measurement, Probe Number = 1, T = 19.969000 C 03:05:50 Temperature Measurement, Probe Number = 2, T = 19.944000 C 03:05:50 Temperature Measurement, Probe Number = 3, T = 19.842000 C 03:05:51 Temperature Measurement, Probe Number = 4, T = 19.922000 C 03:05:51 Temperature Measurement, Probe Number = 5, T = 19.934000 C 03:05:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:05:52 Integrated Voltage Measurement... 03:06:14 Voltage Offset Correction: v_off_ini = -0.000002326 V, v_off_fin = 0.000000205 V 03:06:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158419499 Vs 03:06:14 Integrated Voltage Measurement... 03:06:36 Voltage Offset Correction: v_off_ini = 0.000000585 V, v_off_fin = -0.000000300 V 03:06:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158416621 Vs 03:06:50 Temperature Measurement, Probe Number = 0, T = 19.577000 C 03:06:50 Temperature Measurement, Probe Number = 1, T = 19.968000 C 03:06:51 Temperature Measurement, Probe Number = 2, T = 19.948000 C 03:06:52 Temperature Measurement, Probe Number = 3, T = 19.843000 C 03:06:52 Temperature Measurement, Probe Number = 4, T = 19.920000 C 03:06:53 Temperature Measurement, Probe Number = 5, T = 19.931000 C 03:06:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:06:53 Integrated Voltage Measurement... 03:07:15 Voltage Offset Correction: v_off_ini = -0.000000183 V, v_off_fin = -0.000000007 V 03:07:15 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158425242 Vs 03:07:15 Integrated Voltage Measurement... 03:07:37 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000001047 V 03:07:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401426 Vs 03:07:51 Temperature Measurement, Probe Number = 0, T = 19.587000 C 03:07:52 Temperature Measurement, Probe Number = 1, T = 19.966000 C 03:07:52 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:07:53 Temperature Measurement, Probe Number = 3, T = 19.844000 C 03:07:53 Temperature Measurement, Probe Number = 4, T = 19.919000 C 03:07:54 Temperature Measurement, Probe Number = 5, T = 19.931000 C 03:07:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:07:54 Integrated Voltage Measurement... 03:08:16 Voltage Offset Correction: v_off_ini = -0.000001493 V, v_off_fin = 0.000000585 V 03:08:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158416047 Vs 03:08:16 Integrated Voltage Measurement... 03:08:38 Voltage Offset Correction: v_off_ini = -0.000000519 V, v_off_fin = -0.000003161 V 03:08:38 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158407317 Vs 03:08:52 Temperature Measurement, Probe Number = 0, T = 19.581000 C 03:08:53 Temperature Measurement, Probe Number = 1, T = 19.968000 C 03:08:53 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:08:54 Temperature Measurement, Probe Number = 3, T = 19.841000 C 03:08:54 Temperature Measurement, Probe Number = 4, T = 19.920000 C 03:08:55 Temperature Measurement, Probe Number = 5, T = 19.932000 C 03:08:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:08:55 Integrated Voltage Measurement... 03:09:17 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000000790 V 03:09:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420371 Vs 03:09:18 Integrated Voltage Measurement... 03:09:40 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000001558 V 03:09:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393046 Vs 03:09:54 Temperature Measurement, Probe Number = 0, T = 19.575000 C 03:09:54 Temperature Measurement, Probe Number = 1, T = 19.962000 C 03:09:55 Temperature Measurement, Probe Number = 2, T = 19.940000 C 03:09:55 Temperature Measurement, Probe Number = 3, T = 19.841000 C 03:09:56 Temperature Measurement, Probe Number = 4, T = 19.919000 C 03:09:57 Temperature Measurement, Probe Number = 5, T = 19.930000 C 03:09:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:09:57 Integrated Voltage Measurement... 03:10:19 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000000659 V 03:10:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415302 Vs 03:10:19 Integrated Voltage Measurement... 03:10:41 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000002634 V 03:10:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391192 Vs 03:10:55 Temperature Measurement, Probe Number = 0, T = 19.607000 C 03:10:55 Temperature Measurement, Probe Number = 1, T = 19.966000 C 03:10:56 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:10:56 Temperature Measurement, Probe Number = 3, T = 19.840000 C 03:10:57 Temperature Measurement, Probe Number = 4, T = 19.920000 C 03:10:58 Temperature Measurement, Probe Number = 5, T = 19.931000 C 03:10:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:10:58 Integrated Voltage Measurement... 03:11:20 Voltage Offset Correction: v_off_ini = -0.000000805 V, v_off_fin = 0.000000410 V 03:11:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409083 Vs 03:11:20 Integrated Voltage Measurement... 03:11:42 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000002319 V 03:11:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399680 Vs 03:11:56 Temperature Measurement, Probe Number = 0, T = 19.615000 C 03:11:56 Temperature Measurement, Probe Number = 1, T = 19.967000 C 03:11:57 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:11:57 Temperature Measurement, Probe Number = 3, T = 19.840000 C 03:11:58 Temperature Measurement, Probe Number = 4, T = 19.919000 C 03:11:59 Temperature Measurement, Probe Number = 5, T = 19.930000 C 03:11:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:11:59 Integrated Voltage Measurement... 03:12:21 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000001317 V 03:12:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414225 Vs 03:12:21 Integrated Voltage Measurement... 03:12:43 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000001909 V 03:12:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383520 Vs 03:12:57 Temperature Measurement, Probe Number = 0, T = 19.618000 C 03:12:57 Temperature Measurement, Probe Number = 1, T = 19.966000 C 03:12:58 Temperature Measurement, Probe Number = 2, T = 19.942000 C 03:12:59 Temperature Measurement, Probe Number = 3, T = 19.837000 C 03:12:59 Temperature Measurement, Probe Number = 4, T = 19.918000 C 03:13:00 Temperature Measurement, Probe Number = 5, T = 19.929000 C 03:13:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 03:13:00 Integrated Voltage Measurement... 03:13:22 Voltage Offset Correction: v_off_ini = -0.000001185 V, v_off_fin = -0.000001573 V 03:13:22 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158420035 Vs 03:13:22 Integrated Voltage Measurement... 03:13:45 Voltage Offset Correction: v_off_ini = 0.000002502 V, v_off_fin = -0.000001595 V 03:13:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417297 Vs 04:09:58 Temperature Measurement, Probe Number = 0, T = 19.736000 C 04:09:59 Temperature Measurement, Probe Number = 1, T = 19.951000 C 04:10:00 Temperature Measurement, Probe Number = 2, T = 19.920000 C 04:10:00 Temperature Measurement, Probe Number = 3, T = 19.828000 C 04:10:01 Temperature Measurement, Probe Number = 4, T = 19.897000 C 04:10:01 Temperature Measurement, Probe Number = 5, T = 19.916000 C 04:10:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.92 04:10:01 Integrated Voltage Measurement... 04:10:24 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = 0.000000359 V 04:10:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158439081 Vs 04:10:24 Integrated Voltage Measurement... 04:10:46 Voltage Offset Correction: v_off_ini = -0.000003402 V, v_off_fin = -0.000002758 V 04:10:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158362766 Vs 04:11:00 Temperature Measurement, Probe Number = 0, T = 19.765000 C 04:11:01 Temperature Measurement, Probe Number = 1, T = 19.947000 C 04:11:01 Temperature Measurement, Probe Number = 2, T = 19.919000 C 04:11:02 Temperature Measurement, Probe Number = 3, T = 19.828000 C 04:11:02 Temperature Measurement, Probe Number = 4, T = 19.898000 C 04:11:03 Temperature Measurement, Probe Number = 5, T = 19.914000 C 04:11:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.91 04:11:03 Integrated Voltage Measurement... 04:11:25 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001668 V 04:11:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158415141 Vs 04:11:25 Integrated Voltage Measurement... 04:11:48 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = -0.000003601 V 04:11:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378498 Vs 04:12:02 Temperature Measurement, Probe Number = 0, T = 19.768000 C 04:12:02 Temperature Measurement, Probe Number = 1, T = 19.950000 C 04:12:03 Temperature Measurement, Probe Number = 2, T = 19.920000 C 04:12:03 Temperature Measurement, Probe Number = 3, T = 19.827000 C 04:12:04 Temperature Measurement, Probe Number = 4, T = 19.897000 C 04:12:05 Temperature Measurement, Probe Number = 5, T = 19.913000 C 04:12:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.90 P6 = Top_Jaw, Value = 19.91 04:12:05 Integrated Voltage Measurement... 04:12:27 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000000234 V 04:12:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158406625 Vs 04:12:28 Integrated Voltage Measurement... 04:12:50 Voltage Offset Correction: v_off_ini = -0.000000154 V, v_off_fin = -0.000002130 V 04:12:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158399104 Vs 04:13:04 Temperature Measurement, Probe Number = 0, T = 19.754000 C 04:13:04 Temperature Measurement, Probe Number = 1, T = 19.946000 C 04:13:05 Temperature Measurement, Probe Number = 2, T = 19.918000 C 04:13:06 Temperature Measurement, Probe Number = 3, T = 19.824000 C 04:13:06 Temperature Measurement, Probe Number = 4, T = 19.895000 C 04:13:07 Temperature Measurement, Probe Number = 5, T = 19.913000 C 04:13:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.75 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:13:07 Integrated Voltage Measurement... 04:13:29 Voltage Offset Correction: v_off_ini = -0.000001903 V, v_off_fin = -0.000001815 V 04:13:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158415420 Vs 04:13:29 Integrated Voltage Measurement... 04:13:51 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000003022 V 04:13:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396688 Vs 04:14:05 Temperature Measurement, Probe Number = 0, T = 19.702000 C 04:14:06 Temperature Measurement, Probe Number = 1, T = 19.944000 C 04:14:06 Temperature Measurement, Probe Number = 2, T = 19.916000 C 04:14:07 Temperature Measurement, Probe Number = 3, T = 19.822000 C 04:14:07 Temperature Measurement, Probe Number = 4, T = 19.894000 C 04:14:08 Temperature Measurement, Probe Number = 5, T = 19.911000 C 04:14:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.70 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:14:08 Integrated Voltage Measurement... 04:14:30 Voltage Offset Correction: v_off_ini = -0.000001961 V, v_off_fin = -0.000003549 V 04:14:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158436499 Vs 04:14:30 Integrated Voltage Measurement... 04:14:53 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000001961 V 04:14:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378711 Vs 04:15:06 Temperature Measurement, Probe Number = 0, T = 19.680000 C 04:15:07 Temperature Measurement, Probe Number = 1, T = 19.945000 C 04:15:07 Temperature Measurement, Probe Number = 2, T = 19.916000 C 04:15:08 Temperature Measurement, Probe Number = 3, T = 19.821000 C 04:15:09 Temperature Measurement, Probe Number = 4, T = 19.894000 C 04:15:09 Temperature Measurement, Probe Number = 5, T = 19.913000 C 04:15:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:15:09 Integrated Voltage Measurement... 04:15:31 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000000819 V 04:15:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405038 Vs 04:15:31 Integrated Voltage Measurement... 04:15:54 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000002196 V 04:15:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382879 Vs 04:16:07 Temperature Measurement, Probe Number = 0, T = 19.687000 C 04:16:08 Temperature Measurement, Probe Number = 1, T = 19.946000 C 04:16:08 Temperature Measurement, Probe Number = 2, T = 19.916000 C 04:16:09 Temperature Measurement, Probe Number = 3, T = 19.822000 C 04:16:10 Temperature Measurement, Probe Number = 4, T = 19.895000 C 04:16:10 Temperature Measurement, Probe Number = 5, T = 19.913000 C 04:16:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:16:10 Integrated Voltage Measurement... 04:16:32 Voltage Offset Correction: v_off_ini = -0.000001823 V, v_off_fin = -0.000001632 V 04:16:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422620 Vs 04:16:32 Integrated Voltage Measurement... 04:16:55 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000003432 V 04:16:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392693 Vs 04:17:08 Temperature Measurement, Probe Number = 0, T = 19.700000 C 04:17:09 Temperature Measurement, Probe Number = 1, T = 19.945000 C 04:17:09 Temperature Measurement, Probe Number = 2, T = 19.919000 C 04:17:10 Temperature Measurement, Probe Number = 3, T = 19.822000 C 04:17:11 Temperature Measurement, Probe Number = 4, T = 19.895000 C 04:17:11 Temperature Measurement, Probe Number = 5, T = 19.911000 C 04:17:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.70 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:17:11 Integrated Voltage Measurement... 04:17:34 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = 0.000001127 V 04:17:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158391395 Vs 04:17:34 Integrated Voltage Measurement... 04:17:56 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000002239 V 04:17:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386885 Vs 04:18:10 Temperature Measurement, Probe Number = 0, T = 19.679000 C 04:18:11 Temperature Measurement, Probe Number = 1, T = 19.942000 C 04:18:11 Temperature Measurement, Probe Number = 2, T = 19.916000 C 04:18:12 Temperature Measurement, Probe Number = 3, T = 19.819000 C 04:18:13 Temperature Measurement, Probe Number = 4, T = 19.893000 C 04:18:13 Temperature Measurement, Probe Number = 5, T = 19.911000 C 04:18:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.92 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:18:13 Integrated Voltage Measurement... 04:18:35 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = 0.000000300 V 04:18:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158410776 Vs 04:18:35 Integrated Voltage Measurement... 04:18:58 Voltage Offset Correction: v_off_ini = -0.000000080 V, v_off_fin = -0.000003336 V 04:18:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404376 Vs 04:19:11 Temperature Measurement, Probe Number = 0, T = 19.661000 C 04:19:12 Temperature Measurement, Probe Number = 1, T = 19.943000 C 04:19:12 Temperature Measurement, Probe Number = 2, T = 19.915000 C 04:19:13 Temperature Measurement, Probe Number = 3, T = 19.818000 C 04:19:14 Temperature Measurement, Probe Number = 4, T = 19.893000 C 04:19:14 Temperature Measurement, Probe Number = 5, T = 19.910000 C 04:19:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.66 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.91 04:19:14 Integrated Voltage Measurement... 04:19:37 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001800 V 04:19:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425269 Vs 04:19:37 Integrated Voltage Measurement... 04:19:59 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000003059 V 04:19:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402469 Vs 05:16:13 Temperature Measurement, Probe Number = 0, T = 19.639000 C 05:16:13 Temperature Measurement, Probe Number = 1, T = 19.926000 C 05:16:14 Temperature Measurement, Probe Number = 2, T = 19.894000 C 05:16:15 Temperature Measurement, Probe Number = 3, T = 19.811000 C 05:16:15 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:16:16 Temperature Measurement, Probe Number = 5, T = 19.893000 C 05:16:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:16:16 Integrated Voltage Measurement... 05:16:38 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = -0.000002232 V 05:16:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158458938 Vs 05:16:39 Integrated Voltage Measurement... 05:17:01 Voltage Offset Correction: v_off_ini = -0.000000988 V, v_off_fin = -0.000002430 V 05:17:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383068 Vs 05:17:15 Temperature Measurement, Probe Number = 0, T = 19.643000 C 05:17:15 Temperature Measurement, Probe Number = 1, T = 19.927000 C 05:17:16 Temperature Measurement, Probe Number = 2, T = 19.895000 C 05:17:17 Temperature Measurement, Probe Number = 3, T = 19.814000 C 05:17:17 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:17:18 Temperature Measurement, Probe Number = 5, T = 19.890000 C 05:17:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:17:18 Integrated Voltage Measurement... 05:17:40 Voltage Offset Correction: v_off_ini = -0.000001852 V, v_off_fin = -0.000000037 V 05:17:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158394370 Vs 05:17:40 Integrated Voltage Measurement... 05:18:07 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = 0.000002664 V 05:18:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417714 Vs 05:18:21 Temperature Measurement, Probe Number = 0, T = 19.628000 C 05:18:21 Temperature Measurement, Probe Number = 1, T = 19.928000 C 05:18:22 Temperature Measurement, Probe Number = 2, T = 19.899000 C 05:18:23 Temperature Measurement, Probe Number = 3, T = 19.813000 C 05:18:23 Temperature Measurement, Probe Number = 4, T = 19.876000 C 05:18:24 Temperature Measurement, Probe Number = 5, T = 19.891000 C 05:18:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:18:24 Integrated Voltage Measurement... 05:18:46 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000000271 V 05:18:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399334 Vs 05:18:46 Integrated Voltage Measurement... 05:19:09 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000001054 V 05:19:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382722 Vs 05:19:22 Temperature Measurement, Probe Number = 0, T = 19.619000 C 05:19:23 Temperature Measurement, Probe Number = 1, T = 19.929000 C 05:19:23 Temperature Measurement, Probe Number = 2, T = 19.899000 C 05:19:24 Temperature Measurement, Probe Number = 3, T = 19.810000 C 05:19:25 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:19:25 Temperature Measurement, Probe Number = 5, T = 19.890000 C 05:19:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:19:25 Integrated Voltage Measurement... 05:19:47 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = -0.000000037 V 05:19:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400588 Vs 05:19:48 Integrated Voltage Measurement... 05:20:11 Voltage Offset Correction: v_off_ini = -0.000001025 V, v_off_fin = -0.000001932 V 05:20:11 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158378322 Vs 05:20:24 Temperature Measurement, Probe Number = 0, T = 19.598000 C 05:20:25 Temperature Measurement, Probe Number = 1, T = 19.925000 C 05:20:26 Temperature Measurement, Probe Number = 2, T = 19.897000 C 05:20:26 Temperature Measurement, Probe Number = 3, T = 19.808000 C 05:20:27 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:20:27 Temperature Measurement, Probe Number = 5, T = 19.890000 C 05:20:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:20:27 Integrated Voltage Measurement... 05:20:50 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001266 V 05:20:50 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158398780 Vs 05:20:50 Integrated Voltage Measurement... 05:21:12 Voltage Offset Correction: v_off_ini = -0.000000607 V, v_off_fin = -0.000003264 V 05:21:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158393906 Vs 05:21:26 Temperature Measurement, Probe Number = 0, T = 19.592000 C 05:21:26 Temperature Measurement, Probe Number = 1, T = 19.928000 C 05:21:27 Temperature Measurement, Probe Number = 2, T = 19.900000 C 05:21:28 Temperature Measurement, Probe Number = 3, T = 19.807000 C 05:21:28 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:21:29 Temperature Measurement, Probe Number = 5, T = 19.888000 C 05:21:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:21:29 Integrated Voltage Measurement... 05:21:51 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = 0.000000198 V 05:21:51 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405802 Vs 05:21:51 Integrated Voltage Measurement... 05:22:13 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000002810 V 05:22:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386846 Vs 05:22:27 Temperature Measurement, Probe Number = 0, T = 19.603000 C 05:22:28 Temperature Measurement, Probe Number = 1, T = 19.925000 C 05:22:28 Temperature Measurement, Probe Number = 2, T = 19.899000 C 05:22:29 Temperature Measurement, Probe Number = 3, T = 19.810000 C 05:22:29 Temperature Measurement, Probe Number = 4, T = 19.874000 C 05:22:30 Temperature Measurement, Probe Number = 5, T = 19.888000 C 05:22:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.89 05:22:30 Integrated Voltage Measurement... 05:22:52 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000000622 V 05:22:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158404729 Vs 05:22:52 Integrated Voltage Measurement... 05:23:14 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000003286 V 05:23:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397485 Vs 05:23:28 Temperature Measurement, Probe Number = 0, T = 19.617000 C 05:23:29 Temperature Measurement, Probe Number = 1, T = 19.927000 C 05:23:29 Temperature Measurement, Probe Number = 2, T = 19.898000 C 05:23:30 Temperature Measurement, Probe Number = 3, T = 19.811000 C 05:23:31 Temperature Measurement, Probe Number = 4, T = 19.873000 C 05:23:31 Temperature Measurement, Probe Number = 5, T = 19.889000 C 05:23:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.89 05:23:31 Integrated Voltage Measurement... 05:23:54 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = 0.000001376 V 05:23:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158384086 Vs 05:23:54 Integrated Voltage Measurement... 05:24:16 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000002752 V 05:24:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390080 Vs 05:24:30 Temperature Measurement, Probe Number = 0, T = 19.632000 C 05:24:30 Temperature Measurement, Probe Number = 1, T = 19.929000 C 05:24:31 Temperature Measurement, Probe Number = 2, T = 19.900000 C 05:24:31 Temperature Measurement, Probe Number = 3, T = 19.810000 C 05:24:32 Temperature Measurement, Probe Number = 4, T = 19.875000 C 05:24:33 Temperature Measurement, Probe Number = 5, T = 19.889000 C 05:24:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.63 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.89 05:24:33 Integrated Voltage Measurement... 05:24:55 Voltage Offset Correction: v_off_ini = -0.000002049 V, v_off_fin = -0.000001895 V 05:24:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421111 Vs 05:24:55 Integrated Voltage Measurement... 05:25:17 Voltage Offset Correction: v_off_ini = -0.000000615 V, v_off_fin = -0.000001727 V 05:25:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387856 Vs 05:25:31 Temperature Measurement, Probe Number = 0, T = 19.637000 C 05:25:32 Temperature Measurement, Probe Number = 1, T = 19.923000 C 05:25:32 Temperature Measurement, Probe Number = 2, T = 19.898000 C 05:25:33 Temperature Measurement, Probe Number = 3, T = 19.809000 C 05:25:34 Temperature Measurement, Probe Number = 4, T = 19.874000 C 05:25:34 Temperature Measurement, Probe Number = 5, T = 19.887000 C 05:25:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.89 05:25:34 Integrated Voltage Measurement... 05:25:56 Voltage Offset Correction: v_off_ini = -0.000002261 V, v_off_fin = -0.000001537 V 05:25:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158395929 Vs 05:25:57 Integrated Voltage Measurement... 05:26:19 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000002613 V 05:26:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384825 Vs 06:22:33 Temperature Measurement, Probe Number = 0, T = 19.579000 C 06:22:34 Temperature Measurement, Probe Number = 1, T = 19.902000 C 06:22:34 Temperature Measurement, Probe Number = 2, T = 19.876000 C 06:22:35 Temperature Measurement, Probe Number = 3, T = 19.790000 C 06:22:36 Temperature Measurement, Probe Number = 4, T = 19.855000 C 06:22:36 Temperature Measurement, Probe Number = 5, T = 19.868000 C 06:22:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:22:36 Integrated Voltage Measurement... 06:22:58 Voltage Offset Correction: v_off_ini = -0.000000622 V, v_off_fin = -0.000000066 V 06:22:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158436223 Vs 06:22:58 Integrated Voltage Measurement... 06:23:21 Voltage Offset Correction: v_off_ini = -0.000000022 V, v_off_fin = -0.000001617 V 06:23:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382388 Vs 06:23:34 Temperature Measurement, Probe Number = 0, T = 19.591000 C 06:23:35 Temperature Measurement, Probe Number = 1, T = 19.905000 C 06:23:36 Temperature Measurement, Probe Number = 2, T = 19.879000 C 06:23:36 Temperature Measurement, Probe Number = 3, T = 19.790000 C 06:23:37 Temperature Measurement, Probe Number = 4, T = 19.856000 C 06:23:37 Temperature Measurement, Probe Number = 5, T = 19.868000 C 06:23:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:23:37 Integrated Voltage Measurement... 06:24:00 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000498 V 06:24:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158397051 Vs 06:24:00 Integrated Voltage Measurement... 06:24:22 Voltage Offset Correction: v_off_ini = -0.000001398 V, v_off_fin = -0.000002283 V 06:24:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379488 Vs 06:24:36 Temperature Measurement, Probe Number = 0, T = 19.597000 C 06:24:36 Temperature Measurement, Probe Number = 1, T = 19.906000 C 06:24:37 Temperature Measurement, Probe Number = 2, T = 19.878000 C 06:24:38 Temperature Measurement, Probe Number = 3, T = 19.792000 C 06:24:38 Temperature Measurement, Probe Number = 4, T = 19.856000 C 06:24:39 Temperature Measurement, Probe Number = 5, T = 19.869000 C 06:24:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:24:39 Integrated Voltage Measurement... 06:25:01 Voltage Offset Correction: v_off_ini = -0.000001910 V, v_off_fin = 0.000000541 V 06:25:01 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158406621 Vs 06:25:01 Integrated Voltage Measurement... 06:25:24 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000002150 V 06:25:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384919 Vs 06:25:38 Temperature Measurement, Probe Number = 0, T = 19.592000 C 06:25:38 Temperature Measurement, Probe Number = 1, T = 19.908000 C 06:25:39 Temperature Measurement, Probe Number = 2, T = 19.881000 C 06:25:39 Temperature Measurement, Probe Number = 3, T = 19.792000 C 06:25:40 Temperature Measurement, Probe Number = 4, T = 19.855000 C 06:25:41 Temperature Measurement, Probe Number = 5, T = 19.869000 C 06:25:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:25:41 Integrated Voltage Measurement... 06:26:03 Voltage Offset Correction: v_off_ini = -0.000001478 V, v_off_fin = -0.000001427 V 06:26:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425571 Vs 06:26:03 Integrated Voltage Measurement... 06:26:25 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000001646 V 06:26:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373305 Vs 06:26:39 Temperature Measurement, Probe Number = 0, T = 19.602000 C 06:26:39 Temperature Measurement, Probe Number = 1, T = 19.905000 C 06:26:40 Temperature Measurement, Probe Number = 2, T = 19.877000 C 06:26:41 Temperature Measurement, Probe Number = 3, T = 19.792000 C 06:26:41 Temperature Measurement, Probe Number = 4, T = 19.854000 C 06:26:42 Temperature Measurement, Probe Number = 5, T = 19.868000 C 06:26:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.87 06:26:42 Integrated Voltage Measurement... 06:27:04 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = -0.000000966 V 06:27:04 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158401069 Vs 06:27:04 Integrated Voltage Measurement... 06:27:26 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002473 V 06:27:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385864 Vs 06:27:40 Temperature Measurement, Probe Number = 0, T = 19.614000 C 06:27:41 Temperature Measurement, Probe Number = 1, T = 19.907000 C 06:27:41 Temperature Measurement, Probe Number = 2, T = 19.879000 C 06:27:42 Temperature Measurement, Probe Number = 3, T = 19.792000 C 06:27:42 Temperature Measurement, Probe Number = 4, T = 19.855000 C 06:27:43 Temperature Measurement, Probe Number = 5, T = 19.869000 C 06:27:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:27:43 Integrated Voltage Measurement... 06:28:05 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = -0.000000673 V 06:28:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400533 Vs 06:28:05 Integrated Voltage Measurement... 06:28:27 Voltage Offset Correction: v_off_ini = -0.000000381 V, v_off_fin = -0.000002078 V 06:28:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379004 Vs 06:28:41 Temperature Measurement, Probe Number = 0, T = 19.618000 C 06:28:42 Temperature Measurement, Probe Number = 1, T = 19.907000 C 06:28:42 Temperature Measurement, Probe Number = 2, T = 19.877000 C 06:28:43 Temperature Measurement, Probe Number = 3, T = 19.790000 C 06:28:43 Temperature Measurement, Probe Number = 4, T = 19.855000 C 06:28:44 Temperature Measurement, Probe Number = 5, T = 19.869000 C 06:28:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:28:44 Integrated Voltage Measurement... 06:29:06 Voltage Offset Correction: v_off_ini = -0.000001053 V, v_off_fin = -0.000000337 V 06:29:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158398885 Vs 06:29:06 Integrated Voltage Measurement... 06:29:28 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000002254 V 06:29:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382645 Vs 06:29:42 Temperature Measurement, Probe Number = 0, T = 19.610000 C 06:29:43 Temperature Measurement, Probe Number = 1, T = 19.905000 C 06:29:43 Temperature Measurement, Probe Number = 2, T = 19.876000 C 06:29:44 Temperature Measurement, Probe Number = 3, T = 19.789000 C 06:29:45 Temperature Measurement, Probe Number = 4, T = 19.854000 C 06:29:45 Temperature Measurement, Probe Number = 5, T = 19.866000 C 06:29:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.87 06:29:45 Integrated Voltage Measurement... 06:30:07 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = 0.000000168 V 06:30:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399498 Vs 06:30:08 Integrated Voltage Measurement... 06:30:30 Voltage Offset Correction: v_off_ini = 0.000000110 V, v_off_fin = -0.000001259 V 06:30:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380945 Vs 06:30:44 Temperature Measurement, Probe Number = 0, T = 19.607000 C 06:30:44 Temperature Measurement, Probe Number = 1, T = 19.904000 C 06:30:45 Temperature Measurement, Probe Number = 2, T = 19.874000 C 06:30:46 Temperature Measurement, Probe Number = 3, T = 19.789000 C 06:30:46 Temperature Measurement, Probe Number = 4, T = 19.852000 C 06:30:47 Temperature Measurement, Probe Number = 5, T = 19.867000 C 06:30:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.87 06:30:47 Integrated Voltage Measurement... 06:31:09 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = 0.000000278 V 06:31:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409794 Vs 06:31:09 Integrated Voltage Measurement... 06:31:32 Voltage Offset Correction: v_off_ini = -0.000000937 V, v_off_fin = -0.000003659 V 06:31:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391376 Vs 06:31:45 Temperature Measurement, Probe Number = 0, T = 19.597000 C 06:31:46 Temperature Measurement, Probe Number = 1, T = 19.904000 C 06:31:46 Temperature Measurement, Probe Number = 2, T = 19.876000 C 06:31:47 Temperature Measurement, Probe Number = 3, T = 19.788000 C 06:31:48 Temperature Measurement, Probe Number = 4, T = 19.853000 C 06:31:48 Temperature Measurement, Probe Number = 5, T = 19.867000 C 06:31:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.87 06:31:48 Integrated Voltage Measurement... 06:32:11 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = 0.000000468 V 06:32:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399204 Vs 06:32:11 Integrated Voltage Measurement... 06:32:33 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = -0.000003220 V 06:32:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384838 Vs 07:28:47 Temperature Measurement, Probe Number = 0, T = 19.577000 C 07:28:47 Temperature Measurement, Probe Number = 1, T = 19.891000 C 07:28:48 Temperature Measurement, Probe Number = 2, T = 19.861000 C 07:28:49 Temperature Measurement, Probe Number = 3, T = 19.773000 C 07:28:49 Temperature Measurement, Probe Number = 4, T = 19.838000 C 07:28:50 Temperature Measurement, Probe Number = 5, T = 19.853000 C 07:28:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:28:50 Integrated Voltage Measurement... 07:29:12 Voltage Offset Correction: v_off_ini = -0.000000505 V, v_off_fin = -0.000001471 V 07:29:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.158445629 Vs 07:29:12 Integrated Voltage Measurement... 07:29:34 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000001895 V 07:29:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390631 Vs 07:29:48 Temperature Measurement, Probe Number = 0, T = 19.585000 C 07:29:48 Temperature Measurement, Probe Number = 1, T = 19.889000 C 07:29:49 Temperature Measurement, Probe Number = 2, T = 19.860000 C 07:29:50 Temperature Measurement, Probe Number = 3, T = 19.774000 C 07:29:50 Temperature Measurement, Probe Number = 4, T = 19.838000 C 07:29:51 Temperature Measurement, Probe Number = 5, T = 19.853000 C 07:29:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:29:51 Integrated Voltage Measurement... 07:30:13 Voltage Offset Correction: v_off_ini = -0.000000636 V, v_off_fin = -0.000001163 V 07:30:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424604 Vs 07:30:13 Integrated Voltage Measurement... 07:30:36 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000003190 V 07:30:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378881 Vs 07:30:49 Temperature Measurement, Probe Number = 0, T = 19.595000 C 07:30:50 Temperature Measurement, Probe Number = 1, T = 19.890000 C 07:30:50 Temperature Measurement, Probe Number = 2, T = 19.860000 C 07:30:51 Temperature Measurement, Probe Number = 3, T = 19.774000 C 07:30:52 Temperature Measurement, Probe Number = 4, T = 19.838000 C 07:30:52 Temperature Measurement, Probe Number = 5, T = 19.854000 C 07:30:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:30:52 Integrated Voltage Measurement... 07:31:14 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = 0.000000439 V 07:31:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158393272 Vs 07:31:14 Integrated Voltage Measurement... 07:31:37 Voltage Offset Correction: v_off_ini = -0.000001156 V, v_off_fin = -0.000001887 V 07:31:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158372597 Vs 07:31:50 Temperature Measurement, Probe Number = 0, T = 19.583000 C 07:31:51 Temperature Measurement, Probe Number = 1, T = 19.890000 C 07:31:51 Temperature Measurement, Probe Number = 2, T = 19.859000 C 07:31:52 Temperature Measurement, Probe Number = 3, T = 19.772000 C 07:31:53 Temperature Measurement, Probe Number = 4, T = 19.838000 C 07:31:53 Temperature Measurement, Probe Number = 5, T = 19.854000 C 07:31:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:31:53 Integrated Voltage Measurement... 07:32:15 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = 0.000000885 V 07:32:15 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158393960 Vs 07:32:15 Integrated Voltage Measurement... 07:32:38 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000003226 V 07:32:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158373891 Vs 07:32:51 Temperature Measurement, Probe Number = 0, T = 19.580000 C 07:32:52 Temperature Measurement, Probe Number = 1, T = 19.890000 C 07:32:53 Temperature Measurement, Probe Number = 2, T = 19.859000 C 07:32:53 Temperature Measurement, Probe Number = 3, T = 19.773000 C 07:32:54 Temperature Measurement, Probe Number = 4, T = 19.837000 C 07:32:54 Temperature Measurement, Probe Number = 5, T = 19.853000 C 07:32:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:32:54 Integrated Voltage Measurement... 07:33:17 Voltage Offset Correction: v_off_ini = -0.000001799 V, v_off_fin = -0.000000841 V 07:33:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158398787 Vs 07:33:17 Integrated Voltage Measurement... 07:33:39 Voltage Offset Correction: v_off_ini = -0.000000132 V, v_off_fin = -0.000003255 V 07:33:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380931 Vs 07:33:52 Temperature Measurement, Probe Number = 0, T = 19.588000 C 07:33:53 Temperature Measurement, Probe Number = 1, T = 19.886000 C 07:33:54 Temperature Measurement, Probe Number = 2, T = 19.858000 C 07:33:54 Temperature Measurement, Probe Number = 3, T = 19.773000 C 07:33:55 Temperature Measurement, Probe Number = 4, T = 19.837000 C 07:33:55 Temperature Measurement, Probe Number = 5, T = 19.852000 C 07:33:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:33:55 Integrated Voltage Measurement... 07:34:18 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = 0.000000322 V 07:34:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392854 Vs 07:34:18 Integrated Voltage Measurement... 07:34:40 Voltage Offset Correction: v_off_ini = -0.000000870 V, v_off_fin = -0.000002165 V 07:34:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387523 Vs 07:34:53 Temperature Measurement, Probe Number = 0, T = 19.579000 C 07:34:54 Temperature Measurement, Probe Number = 1, T = 19.889000 C 07:34:55 Temperature Measurement, Probe Number = 2, T = 19.859000 C 07:34:55 Temperature Measurement, Probe Number = 3, T = 19.774000 C 07:34:56 Temperature Measurement, Probe Number = 4, T = 19.835000 C 07:34:56 Temperature Measurement, Probe Number = 5, T = 19.849000 C 07:34:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:34:56 Integrated Voltage Measurement... 07:35:19 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = -0.000002055 V 07:35:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158396631 Vs 07:35:19 Integrated Voltage Measurement... 07:35:41 Voltage Offset Correction: v_off_ini = -0.000000029 V, v_off_fin = -0.000003423 V 07:35:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374918 Vs 07:35:55 Temperature Measurement, Probe Number = 0, T = 19.592000 C 07:35:55 Temperature Measurement, Probe Number = 1, T = 19.888000 C 07:35:56 Temperature Measurement, Probe Number = 2, T = 19.858000 C 07:35:56 Temperature Measurement, Probe Number = 3, T = 19.775000 C 07:35:57 Temperature Measurement, Probe Number = 4, T = 19.836000 C 07:35:58 Temperature Measurement, Probe Number = 5, T = 19.851000 C 07:35:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:35:58 Integrated Voltage Measurement... 07:36:20 Voltage Offset Correction: v_off_ini = -0.000001718 V, v_off_fin = -0.000000600 V 07:36:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400867 Vs 07:36:20 Integrated Voltage Measurement... 07:36:42 Voltage Offset Correction: v_off_ini = -0.000000358 V, v_off_fin = -0.000003101 V 07:36:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384085 Vs 07:36:56 Temperature Measurement, Probe Number = 0, T = 19.613000 C 07:36:56 Temperature Measurement, Probe Number = 1, T = 19.892000 C 07:36:57 Temperature Measurement, Probe Number = 2, T = 19.863000 C 07:36:58 Temperature Measurement, Probe Number = 3, T = 19.773000 C 07:36:58 Temperature Measurement, Probe Number = 4, T = 19.837000 C 07:36:59 Temperature Measurement, Probe Number = 5, T = 19.852000 C 07:36:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:36:59 Integrated Voltage Measurement... 07:37:21 Voltage Offset Correction: v_off_ini = -0.000001550 V, v_off_fin = -0.000000073 V 07:37:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158393255 Vs 07:37:21 Integrated Voltage Measurement... 07:37:46 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000000826 V 07:37:46 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158375052 Vs 07:38:00 Temperature Measurement, Probe Number = 0, T = 19.612000 C 07:38:01 Temperature Measurement, Probe Number = 1, T = 19.891000 C 07:38:01 Temperature Measurement, Probe Number = 2, T = 19.864000 C 07:38:02 Temperature Measurement, Probe Number = 3, T = 19.773000 C 07:38:02 Temperature Measurement, Probe Number = 4, T = 19.837000 C 07:38:03 Temperature Measurement, Probe Number = 5, T = 19.852000 C 07:38:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.85 07:38:03 Integrated Voltage Measurement... 07:38:25 Voltage Offset Correction: v_off_ini = -0.000001872 V, v_off_fin = -0.000001177 V 07:38:25 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158417264 Vs 07:38:25 Integrated Voltage Measurement... 07:38:47 Voltage Offset Correction: v_off_ini = 0.000000249 V, v_off_fin = -0.000002852 V 07:38:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388233 Vs 08:35:01 Temperature Measurement, Probe Number = 0, T = 19.577000 C 08:35:02 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:35:02 Temperature Measurement, Probe Number = 2, T = 19.846000 C 08:35:03 Temperature Measurement, Probe Number = 3, T = 19.760000 C 08:35:03 Temperature Measurement, Probe Number = 4, T = 19.824000 C 08:35:04 Temperature Measurement, Probe Number = 5, T = 19.837000 C 08:35:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:35:04 Integrated Voltage Measurement... 08:35:27 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000000848 V 08:35:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158435854 Vs 08:35:27 Integrated Voltage Measurement... 08:35:49 Voltage Offset Correction: v_off_ini = -0.000000731 V, v_off_fin = -0.000002296 V 08:35:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388921 Vs 08:36:03 Temperature Measurement, Probe Number = 0, T = 19.594000 C 08:36:03 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:36:04 Temperature Measurement, Probe Number = 2, T = 19.846000 C 08:36:05 Temperature Measurement, Probe Number = 3, T = 19.760000 C 08:36:05 Temperature Measurement, Probe Number = 4, T = 19.824000 C 08:36:06 Temperature Measurement, Probe Number = 5, T = 19.838000 C 08:36:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:36:06 Integrated Voltage Measurement... 08:36:28 Voltage Offset Correction: v_off_ini = -0.000001068 V, v_off_fin = -0.000000380 V 08:36:28 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158395197 Vs 08:36:28 Integrated Voltage Measurement... 08:36:50 Voltage Offset Correction: v_off_ini = -0.000001097 V, v_off_fin = -0.000001967 V 08:36:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158374782 Vs 08:37:04 Temperature Measurement, Probe Number = 0, T = 19.585000 C 08:37:04 Temperature Measurement, Probe Number = 1, T = 19.877000 C 08:37:05 Temperature Measurement, Probe Number = 2, T = 19.848000 C 08:37:06 Temperature Measurement, Probe Number = 3, T = 19.760000 C 08:37:06 Temperature Measurement, Probe Number = 4, T = 19.824000 C 08:37:07 Temperature Measurement, Probe Number = 5, T = 19.839000 C 08:37:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:37:07 Integrated Voltage Measurement... 08:37:29 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000000607 V 08:37:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407096 Vs 08:37:30 Integrated Voltage Measurement... 08:37:52 Voltage Offset Correction: v_off_ini = -0.000000600 V, v_off_fin = -0.000001610 V 08:37:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158384003 Vs 08:38:06 Temperature Measurement, Probe Number = 0, T = 19.578000 C 08:38:06 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:38:07 Temperature Measurement, Probe Number = 2, T = 19.846000 C 08:38:08 Temperature Measurement, Probe Number = 3, T = 19.760000 C 08:38:08 Temperature Measurement, Probe Number = 4, T = 19.824000 C 08:38:09 Temperature Measurement, Probe Number = 5, T = 19.838000 C 08:38:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:38:09 Integrated Voltage Measurement... 08:38:32 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000000571 V 08:38:32 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158405920 Vs 08:38:32 Integrated Voltage Measurement... 08:38:54 Voltage Offset Correction: v_off_ini = 0.000000439 V, v_off_fin = -0.000001961 V 08:38:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386968 Vs 08:39:08 Temperature Measurement, Probe Number = 0, T = 19.566000 C 08:39:09 Temperature Measurement, Probe Number = 1, T = 19.873000 C 08:39:09 Temperature Measurement, Probe Number = 2, T = 19.844000 C 08:39:10 Temperature Measurement, Probe Number = 3, T = 19.756000 C 08:39:11 Temperature Measurement, Probe Number = 4, T = 19.823000 C 08:39:11 Temperature Measurement, Probe Number = 5, T = 19.837000 C 08:39:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:39:11 Integrated Voltage Measurement... 08:39:33 Voltage Offset Correction: v_off_ini = -0.000000731 V, v_off_fin = -0.000001646 V 08:39:34 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158409986 Vs 08:39:34 Integrated Voltage Measurement... 08:39:56 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000002721 V 08:39:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158378955 Vs 08:40:10 Temperature Measurement, Probe Number = 0, T = 19.558000 C 08:40:10 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:40:11 Temperature Measurement, Probe Number = 2, T = 19.843000 C 08:40:12 Temperature Measurement, Probe Number = 3, T = 19.760000 C 08:40:12 Temperature Measurement, Probe Number = 4, T = 19.821000 C 08:40:13 Temperature Measurement, Probe Number = 5, T = 19.836000 C 08:40:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.56 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:40:13 Integrated Voltage Measurement... 08:40:35 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000000497 V 08:40:35 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158414790 Vs 08:40:35 Integrated Voltage Measurement... 08:40:57 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000002970 V 08:40:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387143 Vs 08:41:11 Temperature Measurement, Probe Number = 0, T = 19.576000 C 08:41:11 Temperature Measurement, Probe Number = 1, T = 19.876000 C 08:41:12 Temperature Measurement, Probe Number = 2, T = 19.846000 C 08:41:13 Temperature Measurement, Probe Number = 3, T = 19.761000 C 08:41:13 Temperature Measurement, Probe Number = 4, T = 19.821000 C 08:41:14 Temperature Measurement, Probe Number = 5, T = 19.836000 C 08:41:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:41:14 Integrated Voltage Measurement... 08:41:36 Voltage Offset Correction: v_off_ini = -0.000001968 V, v_off_fin = -0.000001902 V 08:41:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158412222 Vs 08:41:36 Integrated Voltage Measurement... 08:41:58 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001990 V 08:41:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380937 Vs 08:42:12 Temperature Measurement, Probe Number = 0, T = 19.579000 C 08:42:12 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:42:13 Temperature Measurement, Probe Number = 2, T = 19.846000 C 08:42:14 Temperature Measurement, Probe Number = 3, T = 19.759000 C 08:42:14 Temperature Measurement, Probe Number = 4, T = 19.822000 C 08:42:15 Temperature Measurement, Probe Number = 5, T = 19.836000 C 08:42:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:42:15 Integrated Voltage Measurement... 08:42:37 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000000110 V 08:42:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158392745 Vs 08:42:37 Integrated Voltage Measurement... 08:43:00 Voltage Offset Correction: v_off_ini = -0.000001704 V, v_off_fin = -0.000001148 V 08:43:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158369402 Vs 08:43:13 Temperature Measurement, Probe Number = 0, T = 19.581000 C 08:43:14 Temperature Measurement, Probe Number = 1, T = 19.875000 C 08:43:14 Temperature Measurement, Probe Number = 2, T = 19.848000 C 08:43:15 Temperature Measurement, Probe Number = 3, T = 19.759000 C 08:43:16 Temperature Measurement, Probe Number = 4, T = 19.823000 C 08:43:16 Temperature Measurement, Probe Number = 5, T = 19.836000 C 08:43:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:43:16 Integrated Voltage Measurement... 08:43:38 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000000497 V 08:43:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402916 Vs 08:43:38 Integrated Voltage Measurement... 08:44:01 Voltage Offset Correction: v_off_ini = -0.000000578 V, v_off_fin = -0.000002048 V 08:44:01 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158375554 Vs 08:44:14 Temperature Measurement, Probe Number = 0, T = 19.577000 C 08:44:15 Temperature Measurement, Probe Number = 1, T = 19.873000 C 08:44:15 Temperature Measurement, Probe Number = 2, T = 19.844000 C 08:44:16 Temperature Measurement, Probe Number = 3, T = 19.758000 C 08:44:17 Temperature Measurement, Probe Number = 4, T = 19.820000 C 08:44:17 Temperature Measurement, Probe Number = 5, T = 19.837000 C 08:44:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.58 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 08:44:17 Integrated Voltage Measurement... 08:44:39 Voltage Offset Correction: v_off_ini = -0.000001170 V, v_off_fin = -0.000000358 V 08:44:39 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158412880 Vs 08:44:39 Integrated Voltage Measurement... 08:45:02 Voltage Offset Correction: v_off_ini = -0.000000219 V, v_off_fin = -0.000003094 V 08:45:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158381562 Vs 09:41:16 Temperature Measurement, Probe Number = 0, T = 19.601000 C 09:41:16 Temperature Measurement, Probe Number = 1, T = 19.861000 C 09:41:17 Temperature Measurement, Probe Number = 2, T = 19.833000 C 09:41:17 Temperature Measurement, Probe Number = 3, T = 19.753000 C 09:41:18 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:41:19 Temperature Measurement, Probe Number = 5, T = 19.824000 C 09:41:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:41:19 Integrated Voltage Measurement... 09:41:41 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000001785 V 09:41:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158474527 Vs 09:41:41 Integrated Voltage Measurement... 09:42:03 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000966 V 09:42:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385063 Vs 09:42:17 Temperature Measurement, Probe Number = 0, T = 19.592000 C 09:42:17 Temperature Measurement, Probe Number = 1, T = 19.859000 C 09:42:18 Temperature Measurement, Probe Number = 2, T = 19.834000 C 09:42:19 Temperature Measurement, Probe Number = 3, T = 19.753000 C 09:42:19 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:42:20 Temperature Measurement, Probe Number = 5, T = 19.822000 C 09:42:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:42:20 Integrated Voltage Measurement... 09:42:42 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000000827 V 09:42:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405095 Vs 09:42:42 Integrated Voltage Measurement... 09:43:05 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000001822 V 09:43:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385909 Vs 09:43:18 Temperature Measurement, Probe Number = 0, T = 19.597000 C 09:43:19 Temperature Measurement, Probe Number = 1, T = 19.859000 C 09:43:19 Temperature Measurement, Probe Number = 2, T = 19.832000 C 09:43:20 Temperature Measurement, Probe Number = 3, T = 19.750000 C 09:43:21 Temperature Measurement, Probe Number = 4, T = 19.810000 C 09:43:21 Temperature Measurement, Probe Number = 5, T = 19.821000 C 09:43:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:43:21 Integrated Voltage Measurement... 09:43:43 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000001141 V 09:43:43 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158413495 Vs 09:43:43 Integrated Voltage Measurement... 09:44:05 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000001902 V 09:44:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382559 Vs 09:44:19 Temperature Measurement, Probe Number = 0, T = 19.597000 C 09:44:20 Temperature Measurement, Probe Number = 1, T = 19.860000 C 09:44:20 Temperature Measurement, Probe Number = 2, T = 19.836000 C 09:44:21 Temperature Measurement, Probe Number = 3, T = 19.752000 C 09:44:22 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:44:22 Temperature Measurement, Probe Number = 5, T = 19.821000 C 09:44:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:44:22 Integrated Voltage Measurement... 09:44:44 Voltage Offset Correction: v_off_ini = -0.000001777 V, v_off_fin = -0.000000783 V 09:44:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421112 Vs 09:44:44 Integrated Voltage Measurement... 09:45:07 Voltage Offset Correction: v_off_ini = -0.000000402 V, v_off_fin = -0.000001528 V 09:45:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392376 Vs 09:45:20 Temperature Measurement, Probe Number = 0, T = 19.606000 C 09:45:21 Temperature Measurement, Probe Number = 1, T = 19.863000 C 09:45:22 Temperature Measurement, Probe Number = 2, T = 19.838000 C 09:45:22 Temperature Measurement, Probe Number = 3, T = 19.752000 C 09:45:23 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:45:23 Temperature Measurement, Probe Number = 5, T = 19.822000 C 09:45:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.61 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:45:23 Integrated Voltage Measurement... 09:45:46 Voltage Offset Correction: v_off_ini = -0.000000892 V, v_off_fin = 0.000000585 V 09:45:46 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158380337 Vs 09:45:46 Integrated Voltage Measurement... 09:46:08 Voltage Offset Correction: v_off_ini = 0.000000015 V, v_off_fin = -0.000002750 V 09:46:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395151 Vs 09:46:22 Temperature Measurement, Probe Number = 0, T = 19.601000 C 09:46:22 Temperature Measurement, Probe Number = 1, T = 19.862000 C 09:46:23 Temperature Measurement, Probe Number = 2, T = 19.839000 C 09:46:24 Temperature Measurement, Probe Number = 3, T = 19.753000 C 09:46:24 Temperature Measurement, Probe Number = 4, T = 19.810000 C 09:46:25 Temperature Measurement, Probe Number = 5, T = 19.822000 C 09:46:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:46:25 Integrated Voltage Measurement... 09:46:47 Voltage Offset Correction: v_off_ini = -0.000002011 V, v_off_fin = -0.000002289 V 09:46:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158433590 Vs 09:46:47 Integrated Voltage Measurement... 09:47:09 Voltage Offset Correction: v_off_ini = -0.000001521 V, v_off_fin = -0.000000834 V 09:47:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158377328 Vs 09:47:23 Temperature Measurement, Probe Number = 0, T = 19.601000 C 09:47:24 Temperature Measurement, Probe Number = 1, T = 19.860000 C 09:47:24 Temperature Measurement, Probe Number = 2, T = 19.836000 C 09:47:25 Temperature Measurement, Probe Number = 3, T = 19.750000 C 09:47:25 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:47:26 Temperature Measurement, Probe Number = 5, T = 19.823000 C 09:47:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:47:26 Integrated Voltage Measurement... 09:47:48 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000002318 V 09:47:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417974 Vs 09:47:49 Integrated Voltage Measurement... 09:48:11 Voltage Offset Correction: v_off_ini = -0.000001097 V, v_off_fin = -0.000001880 V 09:48:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382880 Vs 09:48:25 Temperature Measurement, Probe Number = 0, T = 19.590000 C 09:48:25 Temperature Measurement, Probe Number = 1, T = 19.860000 C 09:48:26 Temperature Measurement, Probe Number = 2, T = 19.835000 C 09:48:27 Temperature Measurement, Probe Number = 3, T = 19.749000 C 09:48:27 Temperature Measurement, Probe Number = 4, T = 19.811000 C 09:48:28 Temperature Measurement, Probe Number = 5, T = 19.822000 C 09:48:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.59 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:48:28 Integrated Voltage Measurement... 09:48:50 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = -0.000003247 V 09:48:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158423154 Vs 09:48:50 Integrated Voltage Measurement... 09:49:12 Voltage Offset Correction: v_off_ini = -0.000001039 V, v_off_fin = -0.000002838 V 09:49:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387222 Vs 09:49:26 Temperature Measurement, Probe Number = 0, T = 19.571000 C 09:49:27 Temperature Measurement, Probe Number = 1, T = 19.857000 C 09:49:27 Temperature Measurement, Probe Number = 2, T = 19.832000 C 09:49:28 Temperature Measurement, Probe Number = 3, T = 19.750000 C 09:49:29 Temperature Measurement, Probe Number = 4, T = 19.808000 C 09:49:29 Temperature Measurement, Probe Number = 5, T = 19.819000 C 09:49:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:49:29 Integrated Voltage Measurement... 09:49:51 Voltage Offset Correction: v_off_ini = -0.000001609 V, v_off_fin = -0.000000673 V 09:49:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414166 Vs 09:49:52 Integrated Voltage Measurement... 09:50:14 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = -0.000001331 V 09:50:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158388809 Vs 09:50:28 Temperature Measurement, Probe Number = 0, T = 19.568000 C 09:50:28 Temperature Measurement, Probe Number = 1, T = 19.857000 C 09:50:29 Temperature Measurement, Probe Number = 2, T = 19.833000 C 09:50:30 Temperature Measurement, Probe Number = 3, T = 19.749000 C 09:50:30 Temperature Measurement, Probe Number = 4, T = 19.809000 C 09:50:31 Temperature Measurement, Probe Number = 5, T = 19.819000 C 09:50:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 09:50:31 Integrated Voltage Measurement... 09:50:53 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000000768 V 09:50:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410740 Vs 09:50:53 Integrated Voltage Measurement... 09:51:16 Voltage Offset Correction: v_off_ini = 0.000000527 V, v_off_fin = -0.000002421 V 09:51:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403026 Vs 10:47:30 Temperature Measurement, Probe Number = 0, T = 19.664000 C 10:47:31 Temperature Measurement, Probe Number = 1, T = 19.852000 C 10:47:31 Temperature Measurement, Probe Number = 2, T = 19.830000 C 10:47:32 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:47:33 Temperature Measurement, Probe Number = 4, T = 19.805000 C 10:47:33 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:47:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.66 P2 = Top_US_Module, Value = 19.85 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.81 10:47:33 Integrated Voltage Measurement... 10:47:56 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000000293 V 10:47:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158465737 Vs 10:47:56 Integrated Voltage Measurement... 10:48:18 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001734 V 10:48:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392880 Vs 10:48:32 Temperature Measurement, Probe Number = 0, T = 19.668000 C 10:48:33 Temperature Measurement, Probe Number = 1, T = 19.857000 C 10:48:33 Temperature Measurement, Probe Number = 2, T = 19.833000 C 10:48:34 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:48:35 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:48:35 Temperature Measurement, Probe Number = 5, T = 19.815000 C 10:48:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.67 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 10:48:35 Integrated Voltage Measurement... 10:48:57 Voltage Offset Correction: v_off_ini = -0.000002882 V, v_off_fin = -0.000002312 V 10:48:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431798 Vs 10:48:57 Integrated Voltage Measurement... 10:49:20 Voltage Offset Correction: v_off_ini = -0.000000739 V, v_off_fin = -0.000001551 V 10:49:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402299 Vs 10:49:33 Temperature Measurement, Probe Number = 0, T = 19.666000 C 10:49:34 Temperature Measurement, Probe Number = 1, T = 19.856000 C 10:49:35 Temperature Measurement, Probe Number = 2, T = 19.834000 C 10:49:35 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:49:36 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:49:36 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:49:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.67 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.81 10:49:36 Integrated Voltage Measurement... 10:49:59 Voltage Offset Correction: v_off_ini = -0.000002122 V, v_off_fin = -0.000003242 V 10:49:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158445334 Vs 10:49:59 Integrated Voltage Measurement... 10:50:22 Voltage Offset Correction: v_off_ini = 0.000001420 V, v_off_fin = -0.000002312 V 10:50:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426926 Vs 10:50:36 Temperature Measurement, Probe Number = 0, T = 19.688000 C 10:50:36 Temperature Measurement, Probe Number = 1, T = 19.855000 C 10:50:37 Temperature Measurement, Probe Number = 2, T = 19.833000 C 10:50:38 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:50:38 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:50:39 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:50:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.81 10:50:39 Integrated Voltage Measurement... 10:51:01 Voltage Offset Correction: v_off_ini = -0.000002063 V, v_off_fin = -0.000000710 V 10:51:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158416697 Vs 10:51:01 Integrated Voltage Measurement... 10:51:23 Voltage Offset Correction: v_off_ini = 0.000001171 V, v_off_fin = -0.000002305 V 10:51:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419745 Vs 10:51:37 Temperature Measurement, Probe Number = 0, T = 19.692000 C 10:51:37 Temperature Measurement, Probe Number = 1, T = 19.853000 C 10:51:38 Temperature Measurement, Probe Number = 2, T = 19.831000 C 10:51:39 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:51:39 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:51:40 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:51:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 19.85 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.81 10:51:40 Integrated Voltage Measurement... 10:52:02 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = 0.000002481 V 10:52:02 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158401199 Vs 10:52:02 Integrated Voltage Measurement... 10:52:24 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000001551 V 10:52:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398693 Vs 10:52:38 Temperature Measurement, Probe Number = 0, T = 19.713000 C 10:52:39 Temperature Measurement, Probe Number = 1, T = 19.854000 C 10:52:39 Temperature Measurement, Probe Number = 2, T = 19.830000 C 10:52:40 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:52:40 Temperature Measurement, Probe Number = 4, T = 19.805000 C 10:52:41 Temperature Measurement, Probe Number = 5, T = 19.815000 C 10:52:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.71 P2 = Top_US_Module, Value = 19.85 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 10:52:41 Integrated Voltage Measurement... 10:53:03 Voltage Offset Correction: v_off_ini = -0.000001991 V, v_off_fin = -0.000001969 V 10:53:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158430640 Vs 10:53:03 Integrated Voltage Measurement... 10:53:26 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = -0.000002803 V 10:53:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419814 Vs 10:53:39 Temperature Measurement, Probe Number = 0, T = 19.737000 C 10:53:40 Temperature Measurement, Probe Number = 1, T = 19.855000 C 10:53:41 Temperature Measurement, Probe Number = 2, T = 19.833000 C 10:53:41 Temperature Measurement, Probe Number = 3, T = 19.749000 C 10:53:42 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:53:42 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:53:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.81 10:53:42 Integrated Voltage Measurement... 10:54:05 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000000263 V 10:54:05 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158418943 Vs 10:54:05 Integrated Voltage Measurement... 10:54:27 Voltage Offset Correction: v_off_ini = 0.000001134 V, v_off_fin = -0.000002232 V 10:54:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158429109 Vs 10:54:41 Temperature Measurement, Probe Number = 0, T = 19.777000 C 10:54:42 Temperature Measurement, Probe Number = 1, T = 19.857000 C 10:54:42 Temperature Measurement, Probe Number = 2, T = 19.831000 C 10:54:43 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:54:44 Temperature Measurement, Probe Number = 4, T = 19.806000 C 10:54:44 Temperature Measurement, Probe Number = 5, T = 19.816000 C 10:54:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.78 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 10:54:44 Integrated Voltage Measurement... 10:55:06 Voltage Offset Correction: v_off_ini = -0.000002415 V, v_off_fin = -0.000002437 V 10:55:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158438201 Vs 10:55:07 Integrated Voltage Measurement... 10:55:29 Voltage Offset Correction: v_off_ini = 0.000000886 V, v_off_fin = -0.000003264 V 10:55:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414222 Vs 10:55:43 Temperature Measurement, Probe Number = 0, T = 19.775000 C 10:55:43 Temperature Measurement, Probe Number = 1, T = 19.856000 C 10:55:44 Temperature Measurement, Probe Number = 2, T = 19.832000 C 10:55:45 Temperature Measurement, Probe Number = 3, T = 19.748000 C 10:55:45 Temperature Measurement, Probe Number = 4, T = 19.804000 C 10:55:46 Temperature Measurement, Probe Number = 5, T = 19.815000 C 10:55:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 10:55:46 Integrated Voltage Measurement... 10:56:08 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000001896 V 10:56:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158428759 Vs 10:56:08 Integrated Voltage Measurement... 10:56:30 Voltage Offset Correction: v_off_ini = 0.000001955 V, v_off_fin = -0.000001083 V 10:56:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421321 Vs 10:56:44 Temperature Measurement, Probe Number = 0, T = 19.759000 C 10:56:45 Temperature Measurement, Probe Number = 1, T = 19.856000 C 10:56:45 Temperature Measurement, Probe Number = 2, T = 19.832000 C 10:56:46 Temperature Measurement, Probe Number = 3, T = 19.749000 C 10:56:46 Temperature Measurement, Probe Number = 4, T = 19.804000 C 10:56:47 Temperature Measurement, Probe Number = 5, T = 19.814000 C 10:56:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.75 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.81 10:56:47 Integrated Voltage Measurement... 10:57:09 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000205 V 10:57:09 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158443396 Vs 10:57:09 Integrated Voltage Measurement... 10:57:31 Voltage Offset Correction: v_off_ini = 0.000000498 V, v_off_fin = -0.000000468 V 10:57:31 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158412134 Vs 11:53:45 Temperature Measurement, Probe Number = 0, T = 19.851000 C 11:53:46 Temperature Measurement, Probe Number = 1, T = 19.857000 C 11:53:46 Temperature Measurement, Probe Number = 2, T = 19.831000 C 11:53:47 Temperature Measurement, Probe Number = 3, T = 19.759000 C 11:53:47 Temperature Measurement, Probe Number = 4, T = 19.805000 C 11:53:48 Temperature Measurement, Probe Number = 5, T = 19.816000 C 11:53:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:53:48 Integrated Voltage Measurement... 11:54:10 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000001880 V 11:54:11 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.158496966 Vs 11:54:11 Integrated Voltage Measurement... 11:54:33 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = -0.000000527 V 11:54:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431407 Vs 11:54:47 Temperature Measurement, Probe Number = 0, T = 19.853000 C 11:54:47 Temperature Measurement, Probe Number = 1, T = 19.859000 C 11:54:48 Temperature Measurement, Probe Number = 2, T = 19.831000 C 11:54:48 Temperature Measurement, Probe Number = 3, T = 19.760000 C 11:54:49 Temperature Measurement, Probe Number = 4, T = 19.804000 C 11:54:50 Temperature Measurement, Probe Number = 5, T = 19.817000 C 11:54:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:54:50 Integrated Voltage Measurement... 11:55:12 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000001529 V 11:55:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158440107 Vs 11:55:12 Integrated Voltage Measurement... 11:55:34 Voltage Offset Correction: v_off_ini = -0.000001148 V, v_off_fin = -0.000001814 V 11:55:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158406787 Vs 11:55:48 Temperature Measurement, Probe Number = 0, T = 19.847000 C 11:55:48 Temperature Measurement, Probe Number = 1, T = 19.855000 C 11:55:49 Temperature Measurement, Probe Number = 2, T = 19.829000 C 11:55:50 Temperature Measurement, Probe Number = 3, T = 19.760000 C 11:55:50 Temperature Measurement, Probe Number = 4, T = 19.803000 C 11:55:51 Temperature Measurement, Probe Number = 5, T = 19.815000 C 11:55:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:55:51 Integrated Voltage Measurement... 11:56:13 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001112 V 11:56:13 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158448399 Vs 11:56:13 Integrated Voltage Measurement... 11:56:35 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000002209 V 11:56:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427772 Vs 11:56:49 Temperature Measurement, Probe Number = 0, T = 19.832000 C 11:56:50 Temperature Measurement, Probe Number = 1, T = 19.859000 C 11:56:50 Temperature Measurement, Probe Number = 2, T = 19.831000 C 11:56:51 Temperature Measurement, Probe Number = 3, T = 19.759000 C 11:56:52 Temperature Measurement, Probe Number = 4, T = 19.804000 C 11:56:52 Temperature Measurement, Probe Number = 5, T = 19.817000 C 11:56:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.83 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:56:52 Integrated Voltage Measurement... 11:57:15 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000000059 V 11:57:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158429158 Vs 11:57:15 Integrated Voltage Measurement... 11:57:37 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000002722 V 11:57:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422325 Vs 11:57:51 Temperature Measurement, Probe Number = 0, T = 19.824000 C 11:57:51 Temperature Measurement, Probe Number = 1, T = 19.859000 C 11:57:52 Temperature Measurement, Probe Number = 2, T = 19.832000 C 11:57:53 Temperature Measurement, Probe Number = 3, T = 19.760000 C 11:57:53 Temperature Measurement, Probe Number = 4, T = 19.805000 C 11:57:54 Temperature Measurement, Probe Number = 5, T = 19.817000 C 11:57:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:57:54 Integrated Voltage Measurement... 11:58:16 Voltage Offset Correction: v_off_ini = -0.000000541 V, v_off_fin = 0.000000190 V 11:58:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158435330 Vs 11:58:16 Integrated Voltage Measurement... 11:58:39 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000002583 V 11:58:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404621 Vs 11:58:52 Temperature Measurement, Probe Number = 0, T = 19.831000 C 11:58:53 Temperature Measurement, Probe Number = 1, T = 19.861000 C 11:58:53 Temperature Measurement, Probe Number = 2, T = 19.832000 C 11:58:54 Temperature Measurement, Probe Number = 3, T = 19.760000 C 11:58:55 Temperature Measurement, Probe Number = 4, T = 19.804000 C 11:58:55 Temperature Measurement, Probe Number = 5, T = 19.818000 C 11:58:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.83 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:58:55 Integrated Voltage Measurement... 11:59:17 Voltage Offset Correction: v_off_ini = -0.000002553 V, v_off_fin = -0.000001046 V 11:59:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158438660 Vs 11:59:18 Integrated Voltage Measurement... 11:59:40 Voltage Offset Correction: v_off_ini = -0.000000490 V, v_off_fin = -0.000000834 V 11:59:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158428092 Vs 11:59:53 Temperature Measurement, Probe Number = 0, T = 19.815000 C 11:59:54 Temperature Measurement, Probe Number = 1, T = 19.856000 C 11:59:55 Temperature Measurement, Probe Number = 2, T = 19.831000 C 11:59:55 Temperature Measurement, Probe Number = 3, T = 19.760000 C 11:59:56 Temperature Measurement, Probe Number = 4, T = 19.804000 C 11:59:56 Temperature Measurement, Probe Number = 5, T = 19.815000 C 11:59:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 11:59:56 Integrated Voltage Measurement... 12:00:19 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000001478 V 12:00:19 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158446237 Vs 12:00:19 Integrated Voltage Measurement... 12:00:41 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = -0.000002202 V 12:00:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402499 Vs 12:00:55 Temperature Measurement, Probe Number = 0, T = 19.814000 C 12:00:55 Temperature Measurement, Probe Number = 1, T = 19.858000 C 12:00:56 Temperature Measurement, Probe Number = 2, T = 19.832000 C 12:00:57 Temperature Measurement, Probe Number = 3, T = 19.760000 C 12:00:57 Temperature Measurement, Probe Number = 4, T = 19.804000 C 12:00:58 Temperature Measurement, Probe Number = 5, T = 19.815000 C 12:00:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.81 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 12:00:58 Integrated Voltage Measurement... 12:01:20 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000001412 V 12:01:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424603 Vs 12:01:20 Integrated Voltage Measurement... 12:01:42 Voltage Offset Correction: v_off_ini = 0.000000088 V, v_off_fin = -0.000002663 V 12:01:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413996 Vs 12:01:56 Temperature Measurement, Probe Number = 0, T = 19.839000 C 12:01:57 Temperature Measurement, Probe Number = 1, T = 19.858000 C 12:01:57 Temperature Measurement, Probe Number = 2, T = 19.832000 C 12:01:58 Temperature Measurement, Probe Number = 3, T = 19.760000 C 12:01:59 Temperature Measurement, Probe Number = 4, T = 19.804000 C 12:01:59 Temperature Measurement, Probe Number = 5, T = 19.816000 C 12:01:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 12:01:59 Integrated Voltage Measurement... 12:02:21 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001953 V 12:02:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441518 Vs 12:02:22 Integrated Voltage Measurement... 12:02:44 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000002327 V 12:02:44 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158407223 Vs 12:02:57 Temperature Measurement, Probe Number = 0, T = 19.845000 C 12:02:58 Temperature Measurement, Probe Number = 1, T = 19.860000 C 12:02:58 Temperature Measurement, Probe Number = 2, T = 19.832000 C 12:02:59 Temperature Measurement, Probe Number = 3, T = 19.760000 C 12:03:00 Temperature Measurement, Probe Number = 4, T = 19.805000 C 12:03:00 Temperature Measurement, Probe Number = 5, T = 19.816000 C 12:03:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.76 P5 = Bottom_Jaw, Value = 19.80 P6 = Top_Jaw, Value = 19.82 12:03:00 Integrated Voltage Measurement... 12:03:23 Voltage Offset Correction: v_off_ini = -0.000002261 V, v_off_fin = -0.000000037 V 12:03:23 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158436383 Vs 12:03:23 Integrated Voltage Measurement... 12:03:45 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = -0.000003132 V 12:03:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158405882 Vs 12:59:59 Temperature Measurement, Probe Number = 0, T = 19.930000 C 12:59:59 Temperature Measurement, Probe Number = 1, T = 19.867000 C 13:00:00 Temperature Measurement, Probe Number = 2, T = 19.838000 C 13:00:01 Temperature Measurement, Probe Number = 3, T = 19.777000 C 13:00:01 Temperature Measurement, Probe Number = 4, T = 19.811000 C 13:00:02 Temperature Measurement, Probe Number = 5, T = 19.825000 C 13:00:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:00:02 Integrated Voltage Measurement... 13:00:24 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000003351 V 13:00:25 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.158515807 Vs 13:00:25 Integrated Voltage Measurement... 13:00:47 Voltage Offset Correction: v_off_ini = -0.000000717 V, v_off_fin = -0.000003542 V 13:00:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424392 Vs 13:01:01 Temperature Measurement, Probe Number = 0, T = 19.940000 C 13:01:02 Temperature Measurement, Probe Number = 1, T = 19.867000 C 13:01:02 Temperature Measurement, Probe Number = 2, T = 19.838000 C 13:01:03 Temperature Measurement, Probe Number = 3, T = 19.777000 C 13:01:03 Temperature Measurement, Probe Number = 4, T = 19.812000 C 13:01:04 Temperature Measurement, Probe Number = 5, T = 19.824000 C 13:01:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:01:04 Integrated Voltage Measurement... 13:01:26 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000000424 V 13:01:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158438849 Vs 13:01:26 Integrated Voltage Measurement... 13:01:48 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000003791 V 13:01:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418042 Vs 13:02:02 Temperature Measurement, Probe Number = 0, T = 19.947000 C 13:02:03 Temperature Measurement, Probe Number = 1, T = 19.868000 C 13:02:03 Temperature Measurement, Probe Number = 2, T = 19.839000 C 13:02:04 Temperature Measurement, Probe Number = 3, T = 19.777000 C 13:02:04 Temperature Measurement, Probe Number = 4, T = 19.811000 C 13:02:05 Temperature Measurement, Probe Number = 5, T = 19.822000 C 13:02:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:02:05 Integrated Voltage Measurement... 13:02:27 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = 0.000000095 V 13:02:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158435516 Vs 13:02:27 Integrated Voltage Measurement... 13:02:49 Voltage Offset Correction: v_off_ini = -0.000001822 V, v_off_fin = -0.000002635 V 13:02:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421493 Vs 13:03:03 Temperature Measurement, Probe Number = 0, T = 19.941000 C 13:03:04 Temperature Measurement, Probe Number = 1, T = 19.865000 C 13:03:04 Temperature Measurement, Probe Number = 2, T = 19.838000 C 13:03:05 Temperature Measurement, Probe Number = 3, T = 19.778000 C 13:03:05 Temperature Measurement, Probe Number = 4, T = 19.810000 C 13:03:06 Temperature Measurement, Probe Number = 5, T = 19.822000 C 13:03:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:03:06 Integrated Voltage Measurement... 13:03:28 Voltage Offset Correction: v_off_ini = -0.000000936 V, v_off_fin = -0.000000973 V 13:03:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158443089 Vs 13:03:28 Integrated Voltage Measurement... 13:03:50 Voltage Offset Correction: v_off_ini = -0.000001076 V, v_off_fin = -0.000001478 V 13:03:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419723 Vs 13:04:04 Temperature Measurement, Probe Number = 0, T = 19.947000 C 13:04:05 Temperature Measurement, Probe Number = 1, T = 19.865000 C 13:04:05 Temperature Measurement, Probe Number = 2, T = 19.836000 C 13:04:06 Temperature Measurement, Probe Number = 3, T = 19.778000 C 13:04:06 Temperature Measurement, Probe Number = 4, T = 19.811000 C 13:04:07 Temperature Measurement, Probe Number = 5, T = 19.824000 C 13:04:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:04:07 Integrated Voltage Measurement... 13:04:29 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = 0.000000695 V 13:04:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158424018 Vs 13:04:29 Integrated Voltage Measurement... 13:04:51 Voltage Offset Correction: v_off_ini = 0.000001756 V, v_off_fin = -0.000000936 V 13:04:52 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158440441 Vs 13:05:05 Temperature Measurement, Probe Number = 0, T = 19.932000 C 13:05:06 Temperature Measurement, Probe Number = 1, T = 19.865000 C 13:05:06 Temperature Measurement, Probe Number = 2, T = 19.837000 C 13:05:07 Temperature Measurement, Probe Number = 3, T = 19.779000 C 13:05:08 Temperature Measurement, Probe Number = 4, T = 19.811000 C 13:05:08 Temperature Measurement, Probe Number = 5, T = 19.824000 C 13:05:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:05:08 Integrated Voltage Measurement... 13:05:30 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000000585 V 13:05:30 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158445145 Vs 13:05:30 Integrated Voltage Measurement... 13:05:53 Voltage Offset Correction: v_off_ini = -0.000001325 V, v_off_fin = -0.000002708 V 13:05:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158410469 Vs 13:06:06 Temperature Measurement, Probe Number = 0, T = 19.949000 C 13:06:07 Temperature Measurement, Probe Number = 1, T = 19.865000 C 13:06:07 Temperature Measurement, Probe Number = 2, T = 19.838000 C 13:06:08 Temperature Measurement, Probe Number = 3, T = 19.779000 C 13:06:09 Temperature Measurement, Probe Number = 4, T = 19.811000 C 13:06:09 Temperature Measurement, Probe Number = 5, T = 19.823000 C 13:06:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:06:09 Integrated Voltage Measurement... 13:06:31 Voltage Offset Correction: v_off_ini = -0.000002253 V, v_off_fin = -0.000000607 V 13:06:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158445755 Vs 13:06:31 Integrated Voltage Measurement... 13:06:54 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000001463 V 13:06:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423297 Vs 13:07:07 Temperature Measurement, Probe Number = 0, T = 19.955000 C 13:07:08 Temperature Measurement, Probe Number = 1, T = 19.865000 C 13:07:08 Temperature Measurement, Probe Number = 2, T = 19.838000 C 13:07:09 Temperature Measurement, Probe Number = 3, T = 19.779000 C 13:07:10 Temperature Measurement, Probe Number = 4, T = 19.812000 C 13:07:10 Temperature Measurement, Probe Number = 5, T = 19.824000 C 13:07:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:07:10 Integrated Voltage Measurement... 13:07:32 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = 0.000000439 V 13:07:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158435871 Vs 13:07:33 Integrated Voltage Measurement... 13:07:55 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = -0.000002107 V 13:07:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432935 Vs 13:08:09 Temperature Measurement, Probe Number = 0, T = 19.954000 C 13:08:09 Temperature Measurement, Probe Number = 1, T = 19.868000 C 13:08:10 Temperature Measurement, Probe Number = 2, T = 19.839000 C 13:08:11 Temperature Measurement, Probe Number = 3, T = 19.780000 C 13:08:11 Temperature Measurement, Probe Number = 4, T = 19.812000 C 13:08:12 Temperature Measurement, Probe Number = 5, T = 19.825000 C 13:08:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:08:12 Integrated Voltage Measurement... 13:08:34 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = 0.000000497 V 13:08:34 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158435784 Vs 13:08:34 Integrated Voltage Measurement... 13:08:56 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000003635 V 13:08:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412410 Vs 13:09:10 Temperature Measurement, Probe Number = 0, T = 19.948000 C 13:09:11 Temperature Measurement, Probe Number = 1, T = 19.867000 C 13:09:11 Temperature Measurement, Probe Number = 2, T = 19.840000 C 13:09:12 Temperature Measurement, Probe Number = 3, T = 19.781000 C 13:09:12 Temperature Measurement, Probe Number = 4, T = 19.812000 C 13:09:13 Temperature Measurement, Probe Number = 5, T = 19.823000 C 13:09:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.81 P6 = Top_Jaw, Value = 19.82 13:09:13 Integrated Voltage Measurement... 13:09:35 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001639 V 13:09:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158450081 Vs 13:09:35 Integrated Voltage Measurement... 13:09:58 Voltage Offset Correction: v_off_ini = -0.000000519 V, v_off_fin = -0.000001704 V 13:09:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423209 Vs 14:06:11 Temperature Measurement, Probe Number = 0, T = 20.006000 C 14:06:12 Temperature Measurement, Probe Number = 1, T = 19.878000 C 14:06:12 Temperature Measurement, Probe Number = 2, T = 19.850000 C 14:06:13 Temperature Measurement, Probe Number = 3, T = 19.800000 C 14:06:14 Temperature Measurement, Probe Number = 4, T = 19.824000 C 14:06:14 Temperature Measurement, Probe Number = 5, T = 19.835000 C 14:06:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 14:06:14 Integrated Voltage Measurement... 14:06:37 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000000541 V 14:06:37 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.158490003 Vs 14:06:37 Integrated Voltage Measurement... 14:06:59 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000003878 V 14:06:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426942 Vs 14:07:13 Temperature Measurement, Probe Number = 0, T = 20.003000 C 14:07:13 Temperature Measurement, Probe Number = 1, T = 19.880000 C 14:07:14 Temperature Measurement, Probe Number = 2, T = 19.852000 C 14:07:15 Temperature Measurement, Probe Number = 3, T = 19.800000 C 14:07:15 Temperature Measurement, Probe Number = 4, T = 19.825000 C 14:07:16 Temperature Measurement, Probe Number = 5, T = 19.835000 C 14:07:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 14:07:16 Integrated Voltage Measurement... 14:07:38 Voltage Offset Correction: v_off_ini = -0.000002231 V, v_off_fin = -0.000001602 V 14:07:38 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158466327 Vs 14:07:38 Integrated Voltage Measurement... 14:08:01 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000002758 V 14:08:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414295 Vs 14:08:14 Temperature Measurement, Probe Number = 0, T = 20.025000 C 14:08:15 Temperature Measurement, Probe Number = 1, T = 19.879000 C 14:08:15 Temperature Measurement, Probe Number = 2, T = 19.852000 C 14:08:16 Temperature Measurement, Probe Number = 3, T = 19.802000 C 14:08:17 Temperature Measurement, Probe Number = 4, T = 19.825000 C 14:08:17 Temperature Measurement, Probe Number = 5, T = 19.835000 C 14:08:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 14:08:17 Integrated Voltage Measurement... 14:08:39 Voltage Offset Correction: v_off_ini = -0.000002209 V, v_off_fin = -0.000001492 V 14:08:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158452283 Vs 14:08:39 Integrated Voltage Measurement... 14:09:02 Voltage Offset Correction: v_off_ini = -0.000000724 V, v_off_fin = -0.000002809 V 14:09:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414738 Vs 14:09:15 Temperature Measurement, Probe Number = 0, T = 20.012000 C 14:09:16 Temperature Measurement, Probe Number = 1, T = 19.878000 C 14:09:16 Temperature Measurement, Probe Number = 2, T = 19.851000 C 14:09:17 Temperature Measurement, Probe Number = 3, T = 19.800000 C 14:09:18 Temperature Measurement, Probe Number = 4, T = 19.825000 C 14:09:18 Temperature Measurement, Probe Number = 5, T = 19.835000 C 14:09:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.84 14:09:18 Integrated Voltage Measurement... 14:09:40 Voltage Offset Correction: v_off_ini = -0.000000702 V, v_off_fin = 0.000001602 V 14:09:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422463 Vs 14:09:40 Integrated Voltage Measurement... 14:10:03 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000001024 V 14:10:03 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158421975 Vs 14:10:16 Temperature Measurement, Probe Number = 0, T = 20.002000 C 14:10:17 Temperature Measurement, Probe Number = 1, T = 19.881000 C 14:10:17 Temperature Measurement, Probe Number = 2, T = 19.853000 C 14:10:18 Temperature Measurement, Probe Number = 3, T = 19.801000 C 14:10:19 Temperature Measurement, Probe Number = 4, T = 19.826000 C 14:10:19 Temperature Measurement, Probe Number = 5, T = 19.835000 C 14:10:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:10:19 Integrated Voltage Measurement... 14:10:42 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = -0.000002261 V 14:10:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158458604 Vs 14:10:42 Integrated Voltage Measurement... 14:11:04 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000002195 V 14:11:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423283 Vs 14:11:18 Temperature Measurement, Probe Number = 0, T = 20.009000 C 14:11:18 Temperature Measurement, Probe Number = 1, T = 19.883000 C 14:11:19 Temperature Measurement, Probe Number = 2, T = 19.855000 C 14:11:19 Temperature Measurement, Probe Number = 3, T = 19.801000 C 14:11:20 Temperature Measurement, Probe Number = 4, T = 19.827000 C 14:11:21 Temperature Measurement, Probe Number = 5, T = 19.836000 C 14:11:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:11:21 Integrated Voltage Measurement... 14:11:43 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000000322 V 14:11:43 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158453090 Vs 14:11:43 Integrated Voltage Measurement... 14:12:05 Voltage Offset Correction: v_off_ini = -0.000000592 V, v_off_fin = -0.000003189 V 14:12:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420149 Vs 14:12:19 Temperature Measurement, Probe Number = 0, T = 20.022000 C 14:12:19 Temperature Measurement, Probe Number = 1, T = 19.881000 C 14:12:20 Temperature Measurement, Probe Number = 2, T = 19.855000 C 14:12:21 Temperature Measurement, Probe Number = 3, T = 19.802000 C 14:12:21 Temperature Measurement, Probe Number = 4, T = 19.827000 C 14:12:22 Temperature Measurement, Probe Number = 5, T = 19.836000 C 14:12:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:12:22 Integrated Voltage Measurement... 14:12:44 Voltage Offset Correction: v_off_ini = -0.000000914 V, v_off_fin = 0.000000234 V 14:12:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437239 Vs 14:12:44 Integrated Voltage Measurement... 14:13:06 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000001470 V 14:13:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423532 Vs 14:13:20 Temperature Measurement, Probe Number = 0, T = 20.017000 C 14:13:20 Temperature Measurement, Probe Number = 1, T = 19.883000 C 14:13:21 Temperature Measurement, Probe Number = 2, T = 19.855000 C 14:13:22 Temperature Measurement, Probe Number = 3, T = 19.803000 C 14:13:22 Temperature Measurement, Probe Number = 4, T = 19.827000 C 14:13:23 Temperature Measurement, Probe Number = 5, T = 19.838000 C 14:13:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:13:23 Integrated Voltage Measurement... 14:13:45 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000001667 V 14:13:46 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158460747 Vs 14:13:46 Integrated Voltage Measurement... 14:14:08 Voltage Offset Correction: v_off_ini = -0.000001755 V, v_off_fin = -0.000000614 V 14:14:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435033 Vs 14:14:22 Temperature Measurement, Probe Number = 0, T = 20.018000 C 14:14:23 Temperature Measurement, Probe Number = 1, T = 19.884000 C 14:14:23 Temperature Measurement, Probe Number = 2, T = 19.855000 C 14:14:24 Temperature Measurement, Probe Number = 3, T = 19.803000 C 14:14:25 Temperature Measurement, Probe Number = 4, T = 19.828000 C 14:14:25 Temperature Measurement, Probe Number = 5, T = 19.837000 C 14:14:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:14:25 Integrated Voltage Measurement... 14:14:48 Voltage Offset Correction: v_off_ini = -0.000001726 V, v_off_fin = 0.000000088 V 14:14:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158438178 Vs 14:14:48 Integrated Voltage Measurement... 14:15:10 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000002649 V 14:15:10 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158413560 Vs 14:15:23 Temperature Measurement, Probe Number = 0, T = 20.012000 C 14:15:24 Temperature Measurement, Probe Number = 1, T = 19.882000 C 14:15:24 Temperature Measurement, Probe Number = 2, T = 19.855000 C 14:15:25 Temperature Measurement, Probe Number = 3, T = 19.803000 C 14:15:26 Temperature Measurement, Probe Number = 4, T = 19.827000 C 14:15:26 Temperature Measurement, Probe Number = 5, T = 19.837000 C 14:15:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.84 14:15:26 Integrated Voltage Measurement... 14:15:49 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000000439 V 14:15:49 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158433320 Vs 14:15:49 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 0.000000161 V, v_off_fin = -0.000002159 V 14:16:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437182 Vs 15:12:26 Temperature Measurement, Probe Number = 0, T = 20.078000 C 15:12:26 Temperature Measurement, Probe Number = 1, T = 19.898000 C 15:12:27 Temperature Measurement, Probe Number = 2, T = 19.873000 C 15:12:28 Temperature Measurement, Probe Number = 3, T = 19.831000 C 15:12:28 Temperature Measurement, Probe Number = 4, T = 19.846000 C 15:12:29 Temperature Measurement, Probe Number = 5, T = 19.852000 C 15:12:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:12:29 Integrated Voltage Measurement... 15:12:51 Voltage Offset Correction: v_off_ini = -0.000000819 V, v_off_fin = 0.000000607 V 15:12:52 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158476274 Vs 15:12:52 Integrated Voltage Measurement... 15:13:14 Voltage Offset Correction: v_off_ini = -0.000001698 V, v_off_fin = -0.000003395 V 15:13:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422587 Vs 15:13:28 Temperature Measurement, Probe Number = 0, T = 20.074000 C 15:13:29 Temperature Measurement, Probe Number = 1, T = 19.899000 C 15:13:29 Temperature Measurement, Probe Number = 2, T = 19.874000 C 15:13:30 Temperature Measurement, Probe Number = 3, T = 19.831000 C 15:13:31 Temperature Measurement, Probe Number = 4, T = 19.847000 C 15:13:31 Temperature Measurement, Probe Number = 5, T = 19.852000 C 15:13:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:13:31 Integrated Voltage Measurement... 15:13:53 Voltage Offset Correction: v_off_ini = -0.000001932 V, v_off_fin = -0.000000117 V 15:13:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158438092 Vs 15:13:53 Integrated Voltage Measurement... 15:14:15 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = -0.000001127 V 15:14:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431005 Vs 15:14:29 Temperature Measurement, Probe Number = 0, T = 20.080000 C 15:14:30 Temperature Measurement, Probe Number = 1, T = 19.900000 C 15:14:30 Temperature Measurement, Probe Number = 2, T = 19.876000 C 15:14:31 Temperature Measurement, Probe Number = 3, T = 19.831000 C 15:14:32 Temperature Measurement, Probe Number = 4, T = 19.848000 C 15:14:32 Temperature Measurement, Probe Number = 5, T = 19.853000 C 15:14:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:14:32 Integrated Voltage Measurement... 15:14:54 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = 0.000001024 V 15:14:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158422435 Vs 15:14:54 Integrated Voltage Measurement... 15:15:17 Voltage Offset Correction: v_off_ini = -0.000001039 V, v_off_fin = -0.000002752 V 15:15:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423173 Vs 15:15:31 Temperature Measurement, Probe Number = 0, T = 20.107000 C 15:15:31 Temperature Measurement, Probe Number = 1, T = 19.900000 C 15:15:32 Temperature Measurement, Probe Number = 2, T = 19.877000 C 15:15:32 Temperature Measurement, Probe Number = 3, T = 19.833000 C 15:15:33 Temperature Measurement, Probe Number = 4, T = 19.848000 C 15:15:34 Temperature Measurement, Probe Number = 5, T = 19.853000 C 15:15:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:15:34 Integrated Voltage Measurement... 15:15:56 Voltage Offset Correction: v_off_ini = -0.000002605 V, v_off_fin = -0.000000644 V 15:15:56 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158437023 Vs 15:15:56 Integrated Voltage Measurement... 15:16:18 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000002839 V 15:16:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418371 Vs 15:16:32 Temperature Measurement, Probe Number = 0, T = 20.119000 C 15:16:32 Temperature Measurement, Probe Number = 1, T = 19.900000 C 15:16:33 Temperature Measurement, Probe Number = 2, T = 19.877000 C 15:16:34 Temperature Measurement, Probe Number = 3, T = 19.834000 C 15:16:34 Temperature Measurement, Probe Number = 4, T = 19.848000 C 15:16:35 Temperature Measurement, Probe Number = 5, T = 19.853000 C 15:16:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.83 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:16:35 Integrated Voltage Measurement... 15:16:57 Voltage Offset Correction: v_off_ini = -0.000002341 V, v_off_fin = -0.000003277 V 15:16:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158460230 Vs 15:16:57 Integrated Voltage Measurement... 15:17:19 Voltage Offset Correction: v_off_ini = -0.000001844 V, v_off_fin = -0.000001844 V 15:17:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421445 Vs 15:17:33 Temperature Measurement, Probe Number = 0, T = 20.130000 C 15:17:34 Temperature Measurement, Probe Number = 1, T = 19.900000 C 15:17:34 Temperature Measurement, Probe Number = 2, T = 19.878000 C 15:17:35 Temperature Measurement, Probe Number = 3, T = 19.835000 C 15:17:36 Temperature Measurement, Probe Number = 4, T = 19.849000 C 15:17:36 Temperature Measurement, Probe Number = 5, T = 19.854000 C 15:17:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:17:36 Integrated Voltage Measurement... 15:17:58 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000000585 V 15:17:58 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158445189 Vs 15:17:58 Integrated Voltage Measurement... 15:18:21 Voltage Offset Correction: v_off_ini = -0.000000271 V, v_off_fin = -0.000003481 V 15:18:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440295 Vs 15:18:34 Temperature Measurement, Probe Number = 0, T = 20.129000 C 15:18:35 Temperature Measurement, Probe Number = 1, T = 19.901000 C 15:18:36 Temperature Measurement, Probe Number = 2, T = 19.877000 C 15:18:36 Temperature Measurement, Probe Number = 3, T = 19.836000 C 15:18:37 Temperature Measurement, Probe Number = 4, T = 19.849000 C 15:18:37 Temperature Measurement, Probe Number = 5, T = 19.854000 C 15:18:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.85 15:18:37 Integrated Voltage Measurement... 15:19:00 Voltage Offset Correction: v_off_ini = -0.000001998 V, v_off_fin = -0.000002685 V 15:19:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456046 Vs 15:19:00 Integrated Voltage Measurement... 15:19:22 Voltage Offset Correction: v_off_ini = -0.000001426 V, v_off_fin = -0.000003175 V 15:19:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417708 Vs 15:19:36 Temperature Measurement, Probe Number = 0, T = 20.108000 C 15:19:36 Temperature Measurement, Probe Number = 1, T = 19.901000 C 15:19:37 Temperature Measurement, Probe Number = 2, T = 19.878000 C 15:19:38 Temperature Measurement, Probe Number = 3, T = 19.836000 C 15:19:38 Temperature Measurement, Probe Number = 4, T = 19.849000 C 15:19:39 Temperature Measurement, Probe Number = 5, T = 19.855000 C 15:19:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 15:19:39 Integrated Voltage Measurement... 15:20:01 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000000139 V 15:20:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422531 Vs 15:20:01 Integrated Voltage Measurement... 15:20:23 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = -0.000001872 V 15:20:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427335 Vs 15:20:37 Temperature Measurement, Probe Number = 0, T = 20.127000 C 15:20:37 Temperature Measurement, Probe Number = 1, T = 19.902000 C 15:20:38 Temperature Measurement, Probe Number = 2, T = 19.878000 C 15:20:39 Temperature Measurement, Probe Number = 3, T = 19.836000 C 15:20:39 Temperature Measurement, Probe Number = 4, T = 19.849000 C 15:20:40 Temperature Measurement, Probe Number = 5, T = 19.855000 C 15:20:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 15:20:40 Integrated Voltage Measurement... 15:21:02 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000000907 V 15:21:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158450834 Vs 15:21:02 Integrated Voltage Measurement... 15:21:25 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002486 V 15:21:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419220 Vs 15:21:38 Temperature Measurement, Probe Number = 0, T = 20.129000 C 15:21:39 Temperature Measurement, Probe Number = 1, T = 19.903000 C 15:21:39 Temperature Measurement, Probe Number = 2, T = 19.880000 C 15:21:40 Temperature Measurement, Probe Number = 3, T = 19.837000 C 15:21:41 Temperature Measurement, Probe Number = 4, T = 19.850000 C 15:21:41 Temperature Measurement, Probe Number = 5, T = 19.856000 C 15:21:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.84 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 15:21:41 Integrated Voltage Measurement... 15:22:03 Voltage Offset Correction: v_off_ini = -0.000002179 V, v_off_fin = 0.000000395 V 15:22:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442865 Vs 15:22:03 Integrated Voltage Measurement... 15:22:26 Voltage Offset Correction: v_off_ini = -0.000001748 V, v_off_fin = -0.000003101 V 15:22:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426892 Vs 16:18:40 Temperature Measurement, Probe Number = 0, T = 20.122000 C 16:18:40 Temperature Measurement, Probe Number = 1, T = 19.922000 C 16:18:41 Temperature Measurement, Probe Number = 2, T = 19.902000 C 16:18:42 Temperature Measurement, Probe Number = 3, T = 19.868000 C 16:18:42 Temperature Measurement, Probe Number = 4, T = 19.875000 C 16:18:43 Temperature Measurement, Probe Number = 5, T = 19.877000 C 16:18:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:18:43 Integrated Voltage Measurement... 16:19:05 Voltage Offset Correction: v_off_ini = -0.000000871 V, v_off_fin = -0.000000739 V 16:19:05 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158531326 Vs 16:19:05 Integrated Voltage Measurement... 16:19:27 Voltage Offset Correction: v_off_ini = 0.000000929 V, v_off_fin = -0.000002487 V 16:19:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441941 Vs 16:19:41 Temperature Measurement, Probe Number = 0, T = 20.121000 C 16:19:41 Temperature Measurement, Probe Number = 1, T = 19.924000 C 16:19:42 Temperature Measurement, Probe Number = 2, T = 19.906000 C 16:19:43 Temperature Measurement, Probe Number = 3, T = 19.867000 C 16:19:43 Temperature Measurement, Probe Number = 4, T = 19.876000 C 16:19:44 Temperature Measurement, Probe Number = 5, T = 19.878000 C 16:19:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:19:44 Integrated Voltage Measurement... 16:20:06 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = 0.000000344 V 16:20:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158432414 Vs 16:20:06 Integrated Voltage Measurement... 16:20:29 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = -0.000002311 V 16:20:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431287 Vs 16:20:43 Temperature Measurement, Probe Number = 0, T = 20.113000 C 16:20:43 Temperature Measurement, Probe Number = 1, T = 19.926000 C 16:20:44 Temperature Measurement, Probe Number = 2, T = 19.904000 C 16:20:45 Temperature Measurement, Probe Number = 3, T = 19.868000 C 16:20:45 Temperature Measurement, Probe Number = 4, T = 19.877000 C 16:20:46 Temperature Measurement, Probe Number = 5, T = 19.877000 C 16:20:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:20:46 Integrated Voltage Measurement... 16:21:08 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001990 V 16:21:08 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158460323 Vs 16:21:08 Integrated Voltage Measurement... 16:21:30 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = -0.000002092 V 16:21:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440745 Vs 16:21:44 Temperature Measurement, Probe Number = 0, T = 20.103000 C 16:21:44 Temperature Measurement, Probe Number = 1, T = 19.924000 C 16:21:45 Temperature Measurement, Probe Number = 2, T = 19.905000 C 16:21:46 Temperature Measurement, Probe Number = 3, T = 19.870000 C 16:21:46 Temperature Measurement, Probe Number = 4, T = 19.877000 C 16:21:47 Temperature Measurement, Probe Number = 5, T = 19.878000 C 16:21:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:21:47 Integrated Voltage Measurement... 16:22:09 Voltage Offset Correction: v_off_ini = -0.000000168 V, v_off_fin = -0.000001390 V 16:22:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442042 Vs 16:22:09 Integrated Voltage Measurement... 16:22:31 Voltage Offset Correction: v_off_ini = -0.000001339 V, v_off_fin = -0.000003299 V 16:22:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158402582 Vs 16:22:45 Temperature Measurement, Probe Number = 0, T = 20.115000 C 16:22:46 Temperature Measurement, Probe Number = 1, T = 19.925000 C 16:22:46 Temperature Measurement, Probe Number = 2, T = 19.906000 C 16:22:47 Temperature Measurement, Probe Number = 3, T = 19.871000 C 16:22:47 Temperature Measurement, Probe Number = 4, T = 19.878000 C 16:22:48 Temperature Measurement, Probe Number = 5, T = 19.879000 C 16:22:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:22:48 Integrated Voltage Measurement... 16:23:10 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = 0.000000059 V 16:23:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158434998 Vs 16:23:11 Integrated Voltage Measurement... 16:23:33 Voltage Offset Correction: v_off_ini = -0.000000132 V, v_off_fin = -0.000003636 V 16:23:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431316 Vs 16:23:46 Temperature Measurement, Probe Number = 0, T = 20.152000 C 16:23:47 Temperature Measurement, Probe Number = 1, T = 19.927000 C 16:23:48 Temperature Measurement, Probe Number = 2, T = 19.908000 C 16:23:48 Temperature Measurement, Probe Number = 3, T = 19.872000 C 16:23:49 Temperature Measurement, Probe Number = 4, T = 19.879000 C 16:23:49 Temperature Measurement, Probe Number = 5, T = 19.880000 C 16:23:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:23:49 Integrated Voltage Measurement... 16:24:12 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000002034 V 16:24:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158462986 Vs 16:24:12 Integrated Voltage Measurement... 16:24:34 Voltage Offset Correction: v_off_ini = 0.000000556 V, v_off_fin = -0.000002407 V 16:24:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442819 Vs 16:24:48 Temperature Measurement, Probe Number = 0, T = 20.137000 C 16:24:48 Temperature Measurement, Probe Number = 1, T = 19.928000 C 16:24:49 Temperature Measurement, Probe Number = 2, T = 19.908000 C 16:24:50 Temperature Measurement, Probe Number = 3, T = 19.871000 C 16:24:50 Temperature Measurement, Probe Number = 4, T = 19.879000 C 16:24:51 Temperature Measurement, Probe Number = 5, T = 19.880000 C 16:24:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:24:51 Integrated Voltage Measurement... 16:25:13 Voltage Offset Correction: v_off_ini = -0.000001537 V, v_off_fin = -0.000001412 V 16:25:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158454974 Vs 16:25:13 Integrated Voltage Measurement... 16:25:36 Voltage Offset Correction: v_off_ini = 0.000000922 V, v_off_fin = -0.000001895 V 16:25:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447930 Vs 16:25:49 Temperature Measurement, Probe Number = 0, T = 20.122000 C 16:25:50 Temperature Measurement, Probe Number = 1, T = 19.927000 C 16:25:50 Temperature Measurement, Probe Number = 2, T = 19.907000 C 16:25:51 Temperature Measurement, Probe Number = 3, T = 19.872000 C 16:25:52 Temperature Measurement, Probe Number = 4, T = 19.879000 C 16:25:52 Temperature Measurement, Probe Number = 5, T = 19.880000 C 16:25:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:25:52 Integrated Voltage Measurement... 16:26:14 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000000585 V 16:26:14 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158451342 Vs 16:26:14 Integrated Voltage Measurement... 16:26:37 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000002078 V 16:26:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424594 Vs 16:26:50 Temperature Measurement, Probe Number = 0, T = 20.125000 C 16:26:51 Temperature Measurement, Probe Number = 1, T = 19.926000 C 16:26:52 Temperature Measurement, Probe Number = 2, T = 19.908000 C 16:26:52 Temperature Measurement, Probe Number = 3, T = 19.873000 C 16:26:53 Temperature Measurement, Probe Number = 4, T = 19.879000 C 16:26:53 Temperature Measurement, Probe Number = 5, T = 19.880000 C 16:26:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:26:53 Integrated Voltage Measurement... 16:27:16 Voltage Offset Correction: v_off_ini = -0.000002408 V, v_off_fin = 0.000001727 V 16:27:16 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158429941 Vs 16:27:16 Integrated Voltage Measurement... 16:27:38 Voltage Offset Correction: v_off_ini = 0.000000761 V, v_off_fin = -0.000002005 V 16:27:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435790 Vs 16:27:52 Temperature Measurement, Probe Number = 0, T = 20.168000 C 16:27:52 Temperature Measurement, Probe Number = 1, T = 19.927000 C 16:27:53 Temperature Measurement, Probe Number = 2, T = 19.908000 C 16:27:54 Temperature Measurement, Probe Number = 3, T = 19.873000 C 16:27:54 Temperature Measurement, Probe Number = 4, T = 19.880000 C 16:27:55 Temperature Measurement, Probe Number = 5, T = 19.880000 C 16:27:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.87 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.88 16:27:55 Integrated Voltage Measurement... 16:28:17 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000002832 V 16:28:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158438549 Vs 16:28:17 Integrated Voltage Measurement... 16:28:39 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000002379 V 16:28:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420488 Vs 17:24:53 Temperature Measurement, Probe Number = 0, T = 20.250000 C 17:24:53 Temperature Measurement, Probe Number = 1, T = 19.953000 C 17:24:54 Temperature Measurement, Probe Number = 2, T = 19.937000 C 17:24:55 Temperature Measurement, Probe Number = 3, T = 19.907000 C 17:24:55 Temperature Measurement, Probe Number = 4, T = 19.909000 C 17:24:56 Temperature Measurement, Probe Number = 5, T = 19.906000 C 17:24:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:24:56 Integrated Voltage Measurement... 17:25:18 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000000073 V 17:25:19 Integrated Voltage Measurement Delta Gap = 0.0040015 m VT = 0.158484061 Vs 17:25:19 Integrated Voltage Measurement... 17:25:41 Voltage Offset Correction: v_off_ini = 0.000000732 V, v_off_fin = -0.000002752 V 17:25:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444318 Vs 17:25:55 Temperature Measurement, Probe Number = 0, T = 20.241000 C 17:25:55 Temperature Measurement, Probe Number = 1, T = 19.954000 C 17:25:56 Temperature Measurement, Probe Number = 2, T = 19.937000 C 17:25:56 Temperature Measurement, Probe Number = 3, T = 19.907000 C 17:25:57 Temperature Measurement, Probe Number = 4, T = 19.910000 C 17:25:58 Temperature Measurement, Probe Number = 5, T = 19.907000 C 17:25:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:25:58 Integrated Voltage Measurement... 17:26:20 Voltage Offset Correction: v_off_ini = -0.000002224 V, v_off_fin = 0.000000088 V 17:26:21 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158451428 Vs 17:26:21 Integrated Voltage Measurement... 17:26:43 Voltage Offset Correction: v_off_ini = 0.000001185 V, v_off_fin = -0.000002070 V 17:26:43 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158451863 Vs 17:26:57 Temperature Measurement, Probe Number = 0, T = 20.232000 C 17:26:57 Temperature Measurement, Probe Number = 1, T = 19.954000 C 17:26:58 Temperature Measurement, Probe Number = 2, T = 19.939000 C 17:26:59 Temperature Measurement, Probe Number = 3, T = 19.908000 C 17:26:59 Temperature Measurement, Probe Number = 4, T = 19.911000 C 17:27:00 Temperature Measurement, Probe Number = 5, T = 19.907000 C 17:27:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:27:00 Integrated Voltage Measurement... 17:27:22 Voltage Offset Correction: v_off_ini = -0.000001148 V, v_off_fin = -0.000001134 V 17:27:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446052 Vs 17:27:22 Integrated Voltage Measurement... 17:27:44 Voltage Offset Correction: v_off_ini = -0.000002838 V, v_off_fin = -0.000003013 V 17:27:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391545 Vs 17:27:58 Temperature Measurement, Probe Number = 0, T = 20.243000 C 17:27:59 Temperature Measurement, Probe Number = 1, T = 19.954000 C 17:27:59 Temperature Measurement, Probe Number = 2, T = 19.941000 C 17:28:00 Temperature Measurement, Probe Number = 3, T = 19.909000 C 17:28:01 Temperature Measurement, Probe Number = 4, T = 19.911000 C 17:28:01 Temperature Measurement, Probe Number = 5, T = 19.907000 C 17:28:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:28:01 Integrated Voltage Measurement... 17:28:23 Voltage Offset Correction: v_off_ini = -0.000002341 V, v_off_fin = -0.000002077 V 17:28:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158461165 Vs 17:28:23 Integrated Voltage Measurement... 17:28:45 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000001770 V 17:28:46 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158412504 Vs 17:28:59 Temperature Measurement, Probe Number = 0, T = 20.250000 C 17:29:00 Temperature Measurement, Probe Number = 1, T = 19.955000 C 17:29:00 Temperature Measurement, Probe Number = 2, T = 19.942000 C 17:29:01 Temperature Measurement, Probe Number = 3, T = 19.910000 C 17:29:02 Temperature Measurement, Probe Number = 4, T = 19.912000 C 17:29:02 Temperature Measurement, Probe Number = 5, T = 19.908000 C 17:29:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:29:02 Integrated Voltage Measurement... 17:29:24 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000000702 V 17:29:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158432628 Vs 17:29:25 Integrated Voltage Measurement... 17:29:47 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000003745 V 17:29:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404640 Vs 17:30:01 Temperature Measurement, Probe Number = 0, T = 20.255000 C 17:30:01 Temperature Measurement, Probe Number = 1, T = 19.956000 C 17:30:02 Temperature Measurement, Probe Number = 2, T = 19.941000 C 17:30:03 Temperature Measurement, Probe Number = 3, T = 19.910000 C 17:30:03 Temperature Measurement, Probe Number = 4, T = 19.913000 C 17:30:04 Temperature Measurement, Probe Number = 5, T = 19.909000 C 17:30:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:30:04 Integrated Voltage Measurement... 17:30:26 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000000848 V 17:30:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455773 Vs 17:30:26 Integrated Voltage Measurement... 17:30:48 Voltage Offset Correction: v_off_ini = 0.000000497 V, v_off_fin = -0.000001397 V 17:30:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418877 Vs 17:31:02 Temperature Measurement, Probe Number = 0, T = 20.249000 C 17:31:02 Temperature Measurement, Probe Number = 1, T = 19.956000 C 17:31:03 Temperature Measurement, Probe Number = 2, T = 19.941000 C 17:31:04 Temperature Measurement, Probe Number = 3, T = 19.910000 C 17:31:04 Temperature Measurement, Probe Number = 4, T = 19.913000 C 17:31:05 Temperature Measurement, Probe Number = 5, T = 19.909000 C 17:31:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:31:05 Integrated Voltage Measurement... 17:31:27 Voltage Offset Correction: v_off_ini = -0.000000505 V, v_off_fin = 0.000000117 V 17:31:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158424947 Vs 17:31:27 Integrated Voltage Measurement... 17:31:50 Voltage Offset Correction: v_off_ini = 0.000000461 V, v_off_fin = -0.000001917 V 17:31:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442433 Vs 17:32:03 Temperature Measurement, Probe Number = 0, T = 20.264000 C 17:32:04 Temperature Measurement, Probe Number = 1, T = 19.956000 C 17:32:04 Temperature Measurement, Probe Number = 2, T = 19.943000 C 17:32:05 Temperature Measurement, Probe Number = 3, T = 19.911000 C 17:32:06 Temperature Measurement, Probe Number = 4, T = 19.914000 C 17:32:06 Temperature Measurement, Probe Number = 5, T = 19.908000 C 17:32:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:32:06 Integrated Voltage Measurement... 17:32:28 Voltage Offset Correction: v_off_ini = -0.000001558 V, v_off_fin = -0.000001587 V 17:32:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158457596 Vs 17:32:28 Integrated Voltage Measurement... 17:32:51 Voltage Offset Correction: v_off_ini = -0.000002911 V, v_off_fin = -0.000004564 V 17:32:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397403 Vs 17:33:04 Temperature Measurement, Probe Number = 0, T = 20.261000 C 17:33:05 Temperature Measurement, Probe Number = 1, T = 19.957000 C 17:33:05 Temperature Measurement, Probe Number = 2, T = 19.945000 C 17:33:06 Temperature Measurement, Probe Number = 3, T = 19.911000 C 17:33:07 Temperature Measurement, Probe Number = 4, T = 19.914000 C 17:33:07 Temperature Measurement, Probe Number = 5, T = 19.910000 C 17:33:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:33:07 Integrated Voltage Measurement... 17:33:29 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000001017 V 17:33:29 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158445495 Vs 17:33:29 Integrated Voltage Measurement... 17:33:52 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = -0.000000936 V 17:33:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431877 Vs 17:34:05 Temperature Measurement, Probe Number = 0, T = 20.270000 C 17:34:06 Temperature Measurement, Probe Number = 1, T = 19.958000 C 17:34:06 Temperature Measurement, Probe Number = 2, T = 19.944000 C 17:34:07 Temperature Measurement, Probe Number = 3, T = 19.913000 C 17:34:08 Temperature Measurement, Probe Number = 4, T = 19.915000 C 17:34:08 Temperature Measurement, Probe Number = 5, T = 19.911000 C 17:34:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.91 17:34:08 Integrated Voltage Measurement... 17:34:30 Voltage Offset Correction: v_off_ini = -0.000001397 V, v_off_fin = -0.000002319 V 17:34:30 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158446269 Vs 17:34:30 Integrated Voltage Measurement... 17:34:53 Voltage Offset Correction: v_off_ini = 0.000001953 V, v_off_fin = -0.000000900 V 17:34:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158450982 Vs 18:31:06 Temperature Measurement, Probe Number = 0, T = 20.252000 C 18:31:07 Temperature Measurement, Probe Number = 1, T = 19.977000 C 18:31:07 Temperature Measurement, Probe Number = 2, T = 19.973000 C 18:31:08 Temperature Measurement, Probe Number = 3, T = 19.945000 C 18:31:09 Temperature Measurement, Probe Number = 4, T = 19.946000 C 18:31:09 Temperature Measurement, Probe Number = 5, T = 19.937000 C 18:31:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:31:09 Integrated Voltage Measurement... 18:31:31 Voltage Offset Correction: v_off_ini = -0.000000037 V, v_off_fin = -0.000001814 V 18:31:31 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158506098 Vs 18:31:31 Integrated Voltage Measurement... 18:31:54 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000003410 V 18:31:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404646 Vs 18:32:07 Temperature Measurement, Probe Number = 0, T = 20.252000 C 18:32:08 Temperature Measurement, Probe Number = 1, T = 19.978000 C 18:32:08 Temperature Measurement, Probe Number = 2, T = 19.975000 C 18:32:09 Temperature Measurement, Probe Number = 3, T = 19.946000 C 18:32:10 Temperature Measurement, Probe Number = 4, T = 19.947000 C 18:32:10 Temperature Measurement, Probe Number = 5, T = 19.937000 C 18:32:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:32:10 Integrated Voltage Measurement... 18:32:32 Voltage Offset Correction: v_off_ini = -0.000002312 V, v_off_fin = -0.000001961 V 18:32:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158441310 Vs 18:32:32 Integrated Voltage Measurement... 18:32:55 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000002122 V 18:32:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158409350 Vs 18:33:08 Temperature Measurement, Probe Number = 0, T = 20.283000 C 18:33:09 Temperature Measurement, Probe Number = 1, T = 19.978000 C 18:33:09 Temperature Measurement, Probe Number = 2, T = 19.976000 C 18:33:10 Temperature Measurement, Probe Number = 3, T = 19.947000 C 18:33:11 Temperature Measurement, Probe Number = 4, T = 19.948000 C 18:33:11 Temperature Measurement, Probe Number = 5, T = 19.937000 C 18:33:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:33:11 Integrated Voltage Measurement... 18:33:34 Voltage Offset Correction: v_off_ini = -0.000000498 V, v_off_fin = -0.000001829 V 18:33:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158432811 Vs 18:33:34 Integrated Voltage Measurement... 18:33:56 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = -0.000002839 V 18:33:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422997 Vs 18:34:09 Temperature Measurement, Probe Number = 0, T = 20.280000 C 18:34:10 Temperature Measurement, Probe Number = 1, T = 19.979000 C 18:34:11 Temperature Measurement, Probe Number = 2, T = 19.976000 C 18:34:11 Temperature Measurement, Probe Number = 3, T = 19.947000 C 18:34:12 Temperature Measurement, Probe Number = 4, T = 19.948000 C 18:34:12 Temperature Measurement, Probe Number = 5, T = 19.938000 C 18:34:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:34:12 Integrated Voltage Measurement... 18:34:35 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = 0.000000761 V 18:34:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431755 Vs 18:34:35 Integrated Voltage Measurement... 18:34:57 Voltage Offset Correction: v_off_ini = -0.000001632 V, v_off_fin = -0.000000410 V 18:34:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417190 Vs 18:35:11 Temperature Measurement, Probe Number = 0, T = 20.294000 C 18:35:11 Temperature Measurement, Probe Number = 1, T = 19.980000 C 18:35:12 Temperature Measurement, Probe Number = 2, T = 19.978000 C 18:35:12 Temperature Measurement, Probe Number = 3, T = 19.948000 C 18:35:13 Temperature Measurement, Probe Number = 4, T = 19.948000 C 18:35:14 Temperature Measurement, Probe Number = 5, T = 19.939000 C 18:35:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:35:14 Integrated Voltage Measurement... 18:35:36 Voltage Offset Correction: v_off_ini = -0.000002173 V, v_off_fin = -0.000002458 V 18:35:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442176 Vs 18:35:36 Integrated Voltage Measurement... 18:35:58 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000002619 V 18:35:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412672 Vs 18:36:12 Temperature Measurement, Probe Number = 0, T = 20.278000 C 18:36:13 Temperature Measurement, Probe Number = 1, T = 19.981000 C 18:36:13 Temperature Measurement, Probe Number = 2, T = 19.978000 C 18:36:14 Temperature Measurement, Probe Number = 3, T = 19.948000 C 18:36:14 Temperature Measurement, Probe Number = 4, T = 19.949000 C 18:36:15 Temperature Measurement, Probe Number = 5, T = 19.940000 C 18:36:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:36:15 Integrated Voltage Measurement... 18:36:37 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001266 V 18:36:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158448644 Vs 18:36:37 Integrated Voltage Measurement... 18:37:00 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000002678 V 18:37:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158409793 Vs 18:37:14 Temperature Measurement, Probe Number = 0, T = 20.274000 C 18:37:14 Temperature Measurement, Probe Number = 1, T = 19.981000 C 18:37:15 Temperature Measurement, Probe Number = 2, T = 19.979000 C 18:37:16 Temperature Measurement, Probe Number = 3, T = 19.946000 C 18:37:16 Temperature Measurement, Probe Number = 4, T = 19.950000 C 18:37:17 Temperature Measurement, Probe Number = 5, T = 19.940000 C 18:37:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:37:17 Integrated Voltage Measurement... 18:37:39 Voltage Offset Correction: v_off_ini = -0.000002041 V, v_off_fin = -0.000000476 V 18:37:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441185 Vs 18:37:39 Integrated Voltage Measurement... 18:38:01 Voltage Offset Correction: v_off_ini = -0.000002670 V, v_off_fin = -0.000003161 V 18:38:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407726 Vs 18:38:15 Temperature Measurement, Probe Number = 0, T = 20.265000 C 18:38:15 Temperature Measurement, Probe Number = 1, T = 19.982000 C 18:38:16 Temperature Measurement, Probe Number = 2, T = 19.980000 C 18:38:17 Temperature Measurement, Probe Number = 3, T = 19.948000 C 18:38:17 Temperature Measurement, Probe Number = 4, T = 19.950000 C 18:38:18 Temperature Measurement, Probe Number = 5, T = 19.940000 C 18:38:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:38:18 Integrated Voltage Measurement... 18:38:40 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000000819 V 18:38:40 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158434994 Vs 18:38:40 Integrated Voltage Measurement... 18:39:02 Voltage Offset Correction: v_off_ini = -0.000001880 V, v_off_fin = -0.000003672 V 18:39:02 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158402819 Vs 18:39:16 Temperature Measurement, Probe Number = 0, T = 20.251000 C 18:39:17 Temperature Measurement, Probe Number = 1, T = 19.983000 C 18:39:17 Temperature Measurement, Probe Number = 2, T = 19.981000 C 18:39:18 Temperature Measurement, Probe Number = 3, T = 19.947000 C 18:39:18 Temperature Measurement, Probe Number = 4, T = 19.952000 C 18:39:19 Temperature Measurement, Probe Number = 5, T = 19.941000 C 18:39:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:39:19 Integrated Voltage Measurement... 18:39:41 Voltage Offset Correction: v_off_ini = -0.000002429 V, v_off_fin = -0.000001697 V 18:39:41 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158427388 Vs 18:39:41 Integrated Voltage Measurement... 18:40:03 Voltage Offset Correction: v_off_ini = -0.000000827 V, v_off_fin = -0.000000878 V 18:40:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158406659 Vs 18:40:17 Temperature Measurement, Probe Number = 0, T = 20.263000 C 18:40:18 Temperature Measurement, Probe Number = 1, T = 19.983000 C 18:40:18 Temperature Measurement, Probe Number = 2, T = 19.982000 C 18:40:19 Temperature Measurement, Probe Number = 3, T = 19.949000 C 18:40:19 Temperature Measurement, Probe Number = 4, T = 19.952000 C 18:40:20 Temperature Measurement, Probe Number = 5, T = 19.941000 C 18:40:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.94 18:40:20 Integrated Voltage Measurement... 18:40:42 Voltage Offset Correction: v_off_ini = -0.000000936 V, v_off_fin = 0.000002246 V 18:40:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158415450 Vs 18:40:42 Integrated Voltage Measurement... 18:41:04 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = -0.000001375 V 18:41:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444416 Vs 19:37:18 Temperature Measurement, Probe Number = 0, T = 20.306000 C 19:37:19 Temperature Measurement, Probe Number = 1, T = 20.010000 C 19:37:19 Temperature Measurement, Probe Number = 2, T = 20.011000 C 19:37:20 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:37:20 Temperature Measurement, Probe Number = 4, T = 19.984000 C 19:37:21 Temperature Measurement, Probe Number = 5, T = 19.969000 C 19:37:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 19:37:21 Integrated Voltage Measurement... 19:37:43 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = -0.000000359 V 19:37:44 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158488036 Vs 19:37:44 Integrated Voltage Measurement... 19:38:06 Voltage Offset Correction: v_off_ini = -0.000001749 V, v_off_fin = -0.000001903 V 19:38:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390043 Vs 19:38:19 Temperature Measurement, Probe Number = 0, T = 20.279000 C 19:38:20 Temperature Measurement, Probe Number = 1, T = 20.012000 C 19:38:20 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:38:21 Temperature Measurement, Probe Number = 3, T = 19.986000 C 19:38:22 Temperature Measurement, Probe Number = 4, T = 19.986000 C 19:38:22 Temperature Measurement, Probe Number = 5, T = 19.970000 C 19:38:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:38:22 Integrated Voltage Measurement... 19:38:45 Voltage Offset Correction: v_off_ini = 0.000000439 V, v_off_fin = 0.000001412 V 19:38:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400181 Vs 19:38:45 Integrated Voltage Measurement... 19:39:07 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000003688 V 19:39:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390802 Vs 19:39:21 Temperature Measurement, Probe Number = 0, T = 20.262000 C 19:39:21 Temperature Measurement, Probe Number = 1, T = 20.012000 C 19:39:22 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:39:23 Temperature Measurement, Probe Number = 3, T = 19.985000 C 19:39:23 Temperature Measurement, Probe Number = 4, T = 19.986000 C 19:39:24 Temperature Measurement, Probe Number = 5, T = 19.970000 C 19:39:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:39:24 Integrated Voltage Measurement... 19:39:46 Voltage Offset Correction: v_off_ini = -0.000002056 V, v_off_fin = 0.000000410 V 19:39:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158415354 Vs 19:39:46 Integrated Voltage Measurement... 19:40:08 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000002752 V 19:40:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397581 Vs 19:40:22 Temperature Measurement, Probe Number = 0, T = 20.267000 C 19:40:22 Temperature Measurement, Probe Number = 1, T = 20.011000 C 19:40:23 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:40:24 Temperature Measurement, Probe Number = 3, T = 19.986000 C 19:40:24 Temperature Measurement, Probe Number = 4, T = 19.986000 C 19:40:25 Temperature Measurement, Probe Number = 5, T = 19.970000 C 19:40:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:40:25 Integrated Voltage Measurement... 19:40:47 Voltage Offset Correction: v_off_ini = -0.000001786 V, v_off_fin = -0.000003366 V 19:40:47 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158432682 Vs 19:40:47 Integrated Voltage Measurement... 19:41:10 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000003192 V 19:41:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389081 Vs 19:41:23 Temperature Measurement, Probe Number = 0, T = 20.258000 C 19:41:24 Temperature Measurement, Probe Number = 1, T = 20.010000 C 19:41:24 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:41:25 Temperature Measurement, Probe Number = 3, T = 19.986000 C 19:41:26 Temperature Measurement, Probe Number = 4, T = 19.985000 C 19:41:26 Temperature Measurement, Probe Number = 5, T = 19.969000 C 19:41:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 19:41:26 Integrated Voltage Measurement... 19:41:49 Voltage Offset Correction: v_off_ini = -0.000001910 V, v_off_fin = 0.000000937 V 19:41:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158402759 Vs 19:41:49 Integrated Voltage Measurement... 19:42:11 Voltage Offset Correction: v_off_ini = 0.000000146 V, v_off_fin = -0.000003608 V 19:42:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397919 Vs 19:42:25 Temperature Measurement, Probe Number = 0, T = 20.264000 C 19:42:25 Temperature Measurement, Probe Number = 1, T = 20.011000 C 19:42:26 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:42:26 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:42:27 Temperature Measurement, Probe Number = 4, T = 19.986000 C 19:42:28 Temperature Measurement, Probe Number = 5, T = 19.969000 C 19:42:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:42:28 Integrated Voltage Measurement... 19:42:50 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000001237 V 19:42:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158412108 Vs 19:42:50 Integrated Voltage Measurement... 19:43:12 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000002225 V 19:43:12 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158409265 Vs 19:43:26 Temperature Measurement, Probe Number = 0, T = 20.251000 C 19:43:27 Temperature Measurement, Probe Number = 1, T = 20.010000 C 19:43:27 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:43:28 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:43:28 Temperature Measurement, Probe Number = 4, T = 19.986000 C 19:43:29 Temperature Measurement, Probe Number = 5, T = 19.970000 C 19:43:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:43:29 Integrated Voltage Measurement... 19:43:51 Voltage Offset Correction: v_off_ini = -0.000001764 V, v_off_fin = -0.000000703 V 19:43:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421052 Vs 19:43:52 Integrated Voltage Measurement... 19:44:14 Voltage Offset Correction: v_off_ini = 0.000000190 V, v_off_fin = -0.000001296 V 19:44:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413644 Vs 19:44:28 Temperature Measurement, Probe Number = 0, T = 20.266000 C 19:44:28 Temperature Measurement, Probe Number = 1, T = 20.012000 C 19:44:29 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:44:29 Temperature Measurement, Probe Number = 3, T = 19.986000 C 19:44:30 Temperature Measurement, Probe Number = 4, T = 19.987000 C 19:44:31 Temperature Measurement, Probe Number = 5, T = 19.970000 C 19:44:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:44:31 Integrated Voltage Measurement... 19:44:53 Voltage Offset Correction: v_off_ini = 0.000000015 V, v_off_fin = -0.000000534 V 19:44:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158411099 Vs 19:44:53 Integrated Voltage Measurement... 19:45:15 Voltage Offset Correction: v_off_ini = 0.000000168 V, v_off_fin = -0.000002313 V 19:45:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404851 Vs 19:45:29 Temperature Measurement, Probe Number = 0, T = 20.298000 C 19:45:30 Temperature Measurement, Probe Number = 1, T = 20.013000 C 19:45:30 Temperature Measurement, Probe Number = 2, T = 20.016000 C 19:45:31 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:45:31 Temperature Measurement, Probe Number = 4, T = 19.988000 C 19:45:32 Temperature Measurement, Probe Number = 5, T = 19.971000 C 19:45:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:45:32 Integrated Voltage Measurement... 19:45:54 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = 0.000000212 V 19:45:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158414279 Vs 19:45:54 Integrated Voltage Measurement... 19:46:17 Voltage Offset Correction: v_off_ini = -0.000001764 V, v_off_fin = -0.000001691 V 19:46:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158383764 Vs 19:46:30 Temperature Measurement, Probe Number = 0, T = 20.310000 C 19:46:31 Temperature Measurement, Probe Number = 1, T = 20.013000 C 19:46:32 Temperature Measurement, Probe Number = 2, T = 20.016000 C 19:46:32 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:46:33 Temperature Measurement, Probe Number = 4, T = 19.988000 C 19:46:33 Temperature Measurement, Probe Number = 5, T = 19.971000 C 19:46:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.31 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.97 19:46:33 Integrated Voltage Measurement... 19:46:56 Voltage Offset Correction: v_off_ini = -0.000001910 V, v_off_fin = -0.000000322 V 19:46:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158417427 Vs 19:46:56 Integrated Voltage Measurement... 19:47:18 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000002840 V 19:47:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158391808 Vs 20:43:31 Temperature Measurement, Probe Number = 0, T = 20.212000 C 20:43:32 Temperature Measurement, Probe Number = 1, T = 20.026000 C 20:43:32 Temperature Measurement, Probe Number = 2, T = 20.033000 C 20:43:33 Temperature Measurement, Probe Number = 3, T = 19.995000 C 20:43:34 Temperature Measurement, Probe Number = 4, T = 20.008000 C 20:43:34 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:43:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:43:34 Integrated Voltage Measurement... 20:43:56 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = 0.000001061 V 20:43:57 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158428182 Vs 20:43:57 Integrated Voltage Measurement... 20:44:19 Voltage Offset Correction: v_off_ini = 0.000000022 V, v_off_fin = -0.000002802 V 20:44:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392476 Vs 20:44:33 Temperature Measurement, Probe Number = 0, T = 20.220000 C 20:44:33 Temperature Measurement, Probe Number = 1, T = 20.026000 C 20:44:34 Temperature Measurement, Probe Number = 2, T = 20.034000 C 20:44:35 Temperature Measurement, Probe Number = 3, T = 19.995000 C 20:44:35 Temperature Measurement, Probe Number = 4, T = 20.008000 C 20:44:36 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:44:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.22 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 20.00 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:44:36 Integrated Voltage Measurement... 20:44:58 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = 0.000000029 V 20:44:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158410012 Vs 20:44:58 Integrated Voltage Measurement... 20:45:20 Voltage Offset Correction: v_off_ini = -0.000002283 V, v_off_fin = -0.000002810 V 20:45:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382490 Vs 20:45:34 Temperature Measurement, Probe Number = 0, T = 20.212000 C 20:45:34 Temperature Measurement, Probe Number = 1, T = 20.026000 C 20:45:35 Temperature Measurement, Probe Number = 2, T = 20.034000 C 20:45:36 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:45:36 Temperature Measurement, Probe Number = 4, T = 20.008000 C 20:45:37 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:45:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:45:37 Integrated Voltage Measurement... 20:45:59 Voltage Offset Correction: v_off_ini = -0.000002268 V, v_off_fin = 0.000000571 V 20:45:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158389310 Vs 20:45:59 Integrated Voltage Measurement... 20:46:21 Voltage Offset Correction: v_off_ini = -0.000001603 V, v_off_fin = -0.000001434 V 20:46:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158382560 Vs 20:46:35 Temperature Measurement, Probe Number = 0, T = 20.189000 C 20:46:36 Temperature Measurement, Probe Number = 1, T = 20.026000 C 20:46:36 Temperature Measurement, Probe Number = 2, T = 20.034000 C 20:46:37 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:46:37 Temperature Measurement, Probe Number = 4, T = 20.008000 C 20:46:38 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:46:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:46:38 Integrated Voltage Measurement... 20:47:00 Voltage Offset Correction: v_off_ini = -0.000001566 V, v_off_fin = -0.000000900 V 20:47:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158409131 Vs 20:47:00 Integrated Voltage Measurement... 20:47:22 Voltage Offset Correction: v_off_ini = -0.000000044 V, v_off_fin = -0.000003418 V 20:47:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158390174 Vs 20:47:36 Temperature Measurement, Probe Number = 0, T = 20.186000 C 20:47:37 Temperature Measurement, Probe Number = 1, T = 20.029000 C 20:47:37 Temperature Measurement, Probe Number = 2, T = 20.035000 C 20:47:38 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:47:38 Temperature Measurement, Probe Number = 4, T = 20.009000 C 20:47:39 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:47:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:47:39 Integrated Voltage Measurement... 20:48:01 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = -0.000000146 V 20:48:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158421589 Vs 20:48:01 Integrated Voltage Measurement... 20:48:23 Voltage Offset Correction: v_off_ini = -0.000001054 V, v_off_fin = -0.000001544 V 20:48:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158387987 Vs 20:48:37 Temperature Measurement, Probe Number = 0, T = 20.161000 C 20:48:38 Temperature Measurement, Probe Number = 1, T = 20.028000 C 20:48:38 Temperature Measurement, Probe Number = 2, T = 20.034000 C 20:48:39 Temperature Measurement, Probe Number = 3, T = 19.993000 C 20:48:39 Temperature Measurement, Probe Number = 4, T = 20.009000 C 20:48:40 Temperature Measurement, Probe Number = 5, T = 19.988000 C 20:48:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:48:40 Integrated Voltage Measurement... 20:49:02 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = 0.000000446 V 20:49:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158399974 Vs 20:49:02 Integrated Voltage Measurement... 20:49:24 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = -0.000002481 V 20:49:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395937 Vs 20:49:38 Temperature Measurement, Probe Number = 0, T = 20.172000 C 20:49:39 Temperature Measurement, Probe Number = 1, T = 20.031000 C 20:49:39 Temperature Measurement, Probe Number = 2, T = 20.036000 C 20:49:40 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:49:40 Temperature Measurement, Probe Number = 4, T = 20.010000 C 20:49:41 Temperature Measurement, Probe Number = 5, T = 19.989000 C 20:49:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:49:41 Integrated Voltage Measurement... 20:50:03 Voltage Offset Correction: v_off_ini = -0.000002078 V, v_off_fin = -0.000002496 V 20:50:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158436996 Vs 20:50:03 Integrated Voltage Measurement... 20:50:25 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000002379 V 20:50:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386598 Vs 20:50:39 Temperature Measurement, Probe Number = 0, T = 20.186000 C 20:50:40 Temperature Measurement, Probe Number = 1, T = 20.029000 C 20:50:40 Temperature Measurement, Probe Number = 2, T = 20.036000 C 20:50:41 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:50:41 Temperature Measurement, Probe Number = 4, T = 20.010000 C 20:50:42 Temperature Measurement, Probe Number = 5, T = 19.989000 C 20:50:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:50:42 Integrated Voltage Measurement... 20:51:04 Voltage Offset Correction: v_off_ini = -0.000002012 V, v_off_fin = -0.000002093 V 20:51:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422994 Vs 20:51:04 Integrated Voltage Measurement... 20:51:26 Voltage Offset Correction: v_off_ini = 0.000000022 V, v_off_fin = -0.000002583 V 20:51:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158400482 Vs 20:51:40 Temperature Measurement, Probe Number = 0, T = 20.174000 C 20:51:41 Temperature Measurement, Probe Number = 1, T = 20.030000 C 20:51:41 Temperature Measurement, Probe Number = 2, T = 20.036000 C 20:51:42 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:51:42 Temperature Measurement, Probe Number = 4, T = 20.011000 C 20:51:43 Temperature Measurement, Probe Number = 5, T = 19.990000 C 20:51:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:51:43 Integrated Voltage Measurement... 20:52:05 Voltage Offset Correction: v_off_ini = -0.000000300 V, v_off_fin = 0.000000908 V 20:52:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158405859 Vs 20:52:05 Integrated Voltage Measurement... 20:52:27 Voltage Offset Correction: v_off_ini = -0.000002196 V, v_off_fin = -0.000004098 V 20:52:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158379359 Vs 20:52:41 Temperature Measurement, Probe Number = 0, T = 20.170000 C 20:52:42 Temperature Measurement, Probe Number = 1, T = 20.031000 C 20:52:42 Temperature Measurement, Probe Number = 2, T = 20.035000 C 20:52:43 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:52:43 Temperature Measurement, Probe Number = 4, T = 20.010000 C 20:52:44 Temperature Measurement, Probe Number = 5, T = 19.990000 C 20:52:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.99 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 20:52:44 Integrated Voltage Measurement... 20:53:06 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000000966 V 20:53:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158401003 Vs 20:53:06 Integrated Voltage Measurement... 20:53:33 Voltage Offset Correction: v_off_ini = -0.000001017 V, v_off_fin = -0.000001969 V 20:53:33 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158399184 Vs 21:49:46 Temperature Measurement, Probe Number = 0, T = 20.052000 C 21:49:47 Temperature Measurement, Probe Number = 1, T = 20.033000 C 21:49:47 Temperature Measurement, Probe Number = 2, T = 20.038000 C 21:49:48 Temperature Measurement, Probe Number = 3, T = 19.984000 C 21:49:49 Temperature Measurement, Probe Number = 4, T = 20.015000 C 21:49:49 Temperature Measurement, Probe Number = 5, T = 19.996000 C 21:49:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:49:49 Integrated Voltage Measurement... 21:50:11 Voltage Offset Correction: v_off_ini = -0.000001962 V, v_off_fin = 0.000003089 V 21:50:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158403509 Vs 21:50:11 Integrated Voltage Measurement... 21:50:33 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = -0.000002758 V 21:50:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386158 Vs 21:50:47 Temperature Measurement, Probe Number = 0, T = 20.037000 C 21:50:48 Temperature Measurement, Probe Number = 1, T = 20.032000 C 21:50:48 Temperature Measurement, Probe Number = 2, T = 20.038000 C 21:50:49 Temperature Measurement, Probe Number = 3, T = 19.983000 C 21:50:50 Temperature Measurement, Probe Number = 4, T = 20.016000 C 21:50:50 Temperature Measurement, Probe Number = 5, T = 19.995000 C 21:50:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:50:50 Integrated Voltage Measurement... 21:51:12 Voltage Offset Correction: v_off_ini = -0.000001866 V, v_off_fin = -0.000001390 V 21:51:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407464 Vs 21:51:12 Integrated Voltage Measurement... 21:51:34 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = -0.000002070 V 21:51:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395924 Vs 21:51:48 Temperature Measurement, Probe Number = 0, T = 20.032000 C 21:51:49 Temperature Measurement, Probe Number = 1, T = 20.033000 C 21:51:49 Temperature Measurement, Probe Number = 2, T = 20.038000 C 21:51:50 Temperature Measurement, Probe Number = 3, T = 19.983000 C 21:51:51 Temperature Measurement, Probe Number = 4, T = 20.015000 C 21:51:51 Temperature Measurement, Probe Number = 5, T = 19.996000 C 21:51:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:51:51 Integrated Voltage Measurement... 21:52:13 Voltage Offset Correction: v_off_ini = -0.000000629 V, v_off_fin = -0.000001288 V 21:52:13 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158423838 Vs 21:52:13 Integrated Voltage Measurement... 21:52:36 Voltage Offset Correction: v_off_ini = 0.000003014 V, v_off_fin = -0.000002692 V 21:52:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435906 Vs 21:52:50 Temperature Measurement, Probe Number = 0, T = 20.027000 C 21:52:50 Temperature Measurement, Probe Number = 1, T = 20.034000 C 21:52:51 Temperature Measurement, Probe Number = 2, T = 20.038000 C 21:52:52 Temperature Measurement, Probe Number = 3, T = 19.983000 C 21:52:52 Temperature Measurement, Probe Number = 4, T = 20.015000 C 21:52:53 Temperature Measurement, Probe Number = 5, T = 19.997000 C 21:52:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:52:53 Integrated Voltage Measurement... 21:53:15 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001031 V 21:53:15 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158418075 Vs 21:53:15 Integrated Voltage Measurement... 21:53:37 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000002084 V 21:53:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158392081 Vs 21:53:51 Temperature Measurement, Probe Number = 0, T = 20.026000 C 21:53:52 Temperature Measurement, Probe Number = 1, T = 20.032000 C 21:53:52 Temperature Measurement, Probe Number = 2, T = 20.037000 C 21:53:53 Temperature Measurement, Probe Number = 3, T = 19.982000 C 21:53:54 Temperature Measurement, Probe Number = 4, T = 20.014000 C 21:53:54 Temperature Measurement, Probe Number = 5, T = 19.994000 C 21:53:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 21:53:54 Integrated Voltage Measurement... 21:54:16 Voltage Offset Correction: v_off_ini = -0.000002194 V, v_off_fin = 0.000000834 V 21:54:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158400787 Vs 21:54:17 Integrated Voltage Measurement... 21:54:39 Voltage Offset Correction: v_off_ini = -0.000000417 V, v_off_fin = -0.000001287 V 21:54:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399566 Vs 21:54:53 Temperature Measurement, Probe Number = 0, T = 20.027000 C 21:54:53 Temperature Measurement, Probe Number = 1, T = 20.033000 C 21:54:54 Temperature Measurement, Probe Number = 2, T = 20.038000 C 21:54:55 Temperature Measurement, Probe Number = 3, T = 19.982000 C 21:54:55 Temperature Measurement, Probe Number = 4, T = 20.014000 C 21:54:56 Temperature Measurement, Probe Number = 5, T = 19.994000 C 21:54:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 21:54:56 Integrated Voltage Measurement... 21:55:18 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000002165 V 21:55:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158432528 Vs 21:55:18 Integrated Voltage Measurement... 21:55:41 Voltage Offset Correction: v_off_ini = -0.000001690 V, v_off_fin = -0.000004507 V 21:55:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158385130 Vs 21:55:54 Temperature Measurement, Probe Number = 0, T = 20.016000 C 21:55:55 Temperature Measurement, Probe Number = 1, T = 20.033000 C 21:55:55 Temperature Measurement, Probe Number = 2, T = 20.040000 C 21:55:56 Temperature Measurement, Probe Number = 3, T = 19.981000 C 21:55:57 Temperature Measurement, Probe Number = 4, T = 20.015000 C 21:55:57 Temperature Measurement, Probe Number = 5, T = 19.995000 C 21:55:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:55:57 Integrated Voltage Measurement... 21:56:19 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000001229 V 21:56:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431831 Vs 21:56:19 Integrated Voltage Measurement... 21:56:46 Voltage Offset Correction: v_off_ini = 0.000002970 V, v_off_fin = -0.000001521 V 21:56:46 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158429064 Vs 21:57:00 Temperature Measurement, Probe Number = 0, T = 20.055000 C 21:57:00 Temperature Measurement, Probe Number = 1, T = 20.036000 C 21:57:01 Temperature Measurement, Probe Number = 2, T = 20.040000 C 21:57:02 Temperature Measurement, Probe Number = 3, T = 19.980000 C 21:57:02 Temperature Measurement, Probe Number = 4, T = 20.013000 C 21:57:03 Temperature Measurement, Probe Number = 5, T = 19.995000 C 21:57:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 21:57:03 Integrated Voltage Measurement... 21:57:25 Voltage Offset Correction: v_off_ini = -0.000002019 V, v_off_fin = 0.000000849 V 21:57:25 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158388868 Vs 21:57:25 Integrated Voltage Measurement... 21:57:48 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001814 V 21:57:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158380552 Vs 21:58:01 Temperature Measurement, Probe Number = 0, T = 20.044000 C 21:58:02 Temperature Measurement, Probe Number = 1, T = 20.033000 C 21:58:02 Temperature Measurement, Probe Number = 2, T = 20.037000 C 21:58:03 Temperature Measurement, Probe Number = 3, T = 19.980000 C 21:58:04 Temperature Measurement, Probe Number = 4, T = 20.014000 C 21:58:04 Temperature Measurement, Probe Number = 5, T = 19.995000 C 21:58:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 20.00 21:58:04 Integrated Voltage Measurement... 21:58:26 Voltage Offset Correction: v_off_ini = -0.000001997 V, v_off_fin = -0.000000446 V 21:58:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158407232 Vs 21:58:26 Integrated Voltage Measurement... 21:58:49 Voltage Offset Correction: v_off_ini = 0.000003146 V, v_off_fin = -0.000002699 V 21:58:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436910 Vs 21:59:02 Temperature Measurement, Probe Number = 0, T = 20.087000 C 21:59:03 Temperature Measurement, Probe Number = 1, T = 20.036000 C 21:59:03 Temperature Measurement, Probe Number = 2, T = 20.039000 C 21:59:04 Temperature Measurement, Probe Number = 3, T = 19.981000 C 21:59:05 Temperature Measurement, Probe Number = 4, T = 20.015000 C 21:59:05 Temperature Measurement, Probe Number = 5, T = 19.995000 C 21:59:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 20.00 21:59:05 Integrated Voltage Measurement... 21:59:27 Voltage Offset Correction: v_off_ini = -0.000001302 V, v_off_fin = 0.000002509 V 21:59:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158396903 Vs 21:59:27 Integrated Voltage Measurement... 21:59:50 Voltage Offset Correction: v_off_ini = -0.000001002 V, v_off_fin = -0.000001478 V 21:59:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158389551 Vs 22:56:04 Temperature Measurement, Probe Number = 0, T = 20.006000 C 22:56:04 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:56:05 Temperature Measurement, Probe Number = 2, T = 20.034000 C 22:56:05 Temperature Measurement, Probe Number = 3, T = 19.966000 C 22:56:06 Temperature Measurement, Probe Number = 4, T = 20.010000 C 22:56:07 Temperature Measurement, Probe Number = 5, T = 19.994000 C 22:56:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 22:56:07 Integrated Voltage Measurement... 22:56:29 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000001259 V 22:56:29 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158428264 Vs 22:56:29 Integrated Voltage Measurement... 22:56:52 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000002560 V 22:56:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396429 Vs 22:57:05 Temperature Measurement, Probe Number = 0, T = 19.995000 C 22:57:06 Temperature Measurement, Probe Number = 1, T = 20.033000 C 22:57:06 Temperature Measurement, Probe Number = 2, T = 20.034000 C 22:57:07 Temperature Measurement, Probe Number = 3, T = 19.965000 C 22:57:08 Temperature Measurement, Probe Number = 4, T = 20.010000 C 22:57:08 Temperature Measurement, Probe Number = 5, T = 19.993000 C 22:57:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 22:57:08 Integrated Voltage Measurement... 22:57:30 Voltage Offset Correction: v_off_ini = -0.000000432 V, v_off_fin = -0.000000234 V 22:57:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158413154 Vs 22:57:31 Integrated Voltage Measurement... 22:57:55 Voltage Offset Correction: v_off_ini = 0.000000139 V, v_off_fin = -0.000002451 V 22:57:55 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158399220 Vs 22:58:09 Temperature Measurement, Probe Number = 0, T = 20.017000 C 22:58:09 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:58:10 Temperature Measurement, Probe Number = 2, T = 20.034000 C 22:58:11 Temperature Measurement, Probe Number = 3, T = 19.963000 C 22:58:11 Temperature Measurement, Probe Number = 4, T = 20.009000 C 22:58:12 Temperature Measurement, Probe Number = 5, T = 19.992000 C 22:58:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 22:58:12 Integrated Voltage Measurement... 22:58:34 Voltage Offset Correction: v_off_ini = -0.000001281 V, v_off_fin = 0.000000805 V 22:58:34 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158405440 Vs 22:58:34 Integrated Voltage Measurement... 22:58:56 Voltage Offset Correction: v_off_ini = -0.000000805 V, v_off_fin = -0.000001946 V 22:58:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414930 Vs 22:59:10 Temperature Measurement, Probe Number = 0, T = 20.021000 C 22:59:11 Temperature Measurement, Probe Number = 1, T = 20.030000 C 22:59:11 Temperature Measurement, Probe Number = 2, T = 20.031000 C 22:59:12 Temperature Measurement, Probe Number = 3, T = 19.963000 C 22:59:12 Temperature Measurement, Probe Number = 4, T = 20.007000 C 22:59:13 Temperature Measurement, Probe Number = 5, T = 19.991000 C 22:59:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 22:59:13 Integrated Voltage Measurement... 22:59:35 Voltage Offset Correction: v_off_ini = -0.000002196 V, v_off_fin = -0.000001039 V 22:59:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158436734 Vs 22:59:35 Integrated Voltage Measurement... 22:59:57 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000003095 V 22:59:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404806 Vs 23:00:11 Temperature Measurement, Probe Number = 0, T = 19.971000 C 23:00:12 Temperature Measurement, Probe Number = 1, T = 20.030000 C 23:00:12 Temperature Measurement, Probe Number = 2, T = 20.029000 C 23:00:13 Temperature Measurement, Probe Number = 3, T = 19.962000 C 23:00:13 Temperature Measurement, Probe Number = 4, T = 20.007000 C 23:00:14 Temperature Measurement, Probe Number = 5, T = 19.991000 C 23:00:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:00:14 Integrated Voltage Measurement... 23:00:36 Voltage Offset Correction: v_off_ini = -0.000002100 V, v_off_fin = -0.000000059 V 23:00:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158425280 Vs 23:00:37 Integrated Voltage Measurement... 23:00:59 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000001639 V 23:00:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158410643 Vs 23:01:12 Temperature Measurement, Probe Number = 0, T = 19.990000 C 23:01:13 Temperature Measurement, Probe Number = 1, T = 20.030000 C 23:01:13 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:01:14 Temperature Measurement, Probe Number = 3, T = 19.964000 C 23:01:15 Temperature Measurement, Probe Number = 4, T = 20.010000 C 23:01:15 Temperature Measurement, Probe Number = 5, T = 19.991000 C 23:01:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:01:15 Integrated Voltage Measurement... 23:01:37 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001171 V 23:01:38 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158427235 Vs 23:01:38 Integrated Voltage Measurement... 23:02:00 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000003864 V 23:02:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412795 Vs 23:02:14 Temperature Measurement, Probe Number = 0, T = 20.000000 C 23:02:14 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:02:15 Temperature Measurement, Probe Number = 2, T = 20.032000 C 23:02:16 Temperature Measurement, Probe Number = 3, T = 19.964000 C 23:02:16 Temperature Measurement, Probe Number = 4, T = 20.010000 C 23:02:17 Temperature Measurement, Probe Number = 5, T = 19.994000 C 23:02:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:02:17 Integrated Voltage Measurement... 23:02:39 Voltage Offset Correction: v_off_ini = 0.000000534 V, v_off_fin = -0.000001273 V 23:02:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158434301 Vs 23:02:39 Integrated Voltage Measurement... 23:03:01 Voltage Offset Correction: v_off_ini = -0.000001602 V, v_off_fin = -0.000003424 V 23:03:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415533 Vs 23:03:15 Temperature Measurement, Probe Number = 0, T = 19.974000 C 23:03:15 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:03:16 Temperature Measurement, Probe Number = 2, T = 20.030000 C 23:03:17 Temperature Measurement, Probe Number = 3, T = 19.963000 C 23:03:17 Temperature Measurement, Probe Number = 4, T = 20.010000 C 23:03:18 Temperature Measurement, Probe Number = 5, T = 19.993000 C 23:03:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:03:18 Integrated Voltage Measurement... 23:03:40 Voltage Offset Correction: v_off_ini = -0.000001698 V, v_off_fin = 0.000000476 V 23:03:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158432386 Vs 23:03:40 Integrated Voltage Measurement... 23:04:02 Voltage Offset Correction: v_off_ini = 0.000001346 V, v_off_fin = -0.000004098 V 23:04:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158450581 Vs 23:04:16 Temperature Measurement, Probe Number = 0, T = 19.979000 C 23:04:17 Temperature Measurement, Probe Number = 1, T = 20.031000 C 23:04:17 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:04:18 Temperature Measurement, Probe Number = 3, T = 19.962000 C 23:04:19 Temperature Measurement, Probe Number = 4, T = 20.008000 C 23:04:19 Temperature Measurement, Probe Number = 5, T = 19.994000 C 23:04:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:04:19 Integrated Voltage Measurement... 23:04:41 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000000761 V 23:04:42 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158447745 Vs 23:04:42 Integrated Voltage Measurement... 23:05:04 Voltage Offset Correction: v_off_ini = -0.000000644 V, v_off_fin = -0.000002086 V 23:05:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422147 Vs 23:05:18 Temperature Measurement, Probe Number = 0, T = 19.993000 C 23:05:18 Temperature Measurement, Probe Number = 1, T = 20.031000 C 23:05:19 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:05:19 Temperature Measurement, Probe Number = 3, T = 19.961000 C 23:05:20 Temperature Measurement, Probe Number = 4, T = 20.008000 C 23:05:21 Temperature Measurement, Probe Number = 5, T = 19.991000 C 23:05:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 20.03 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.99 23:05:21 Integrated Voltage Measurement... 23:05:43 Voltage Offset Correction: v_off_ini = -0.000001793 V, v_off_fin = -0.000001464 V 23:05:44 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158434264 Vs 23:05:44 Integrated Voltage Measurement... 23:06:06 Voltage Offset Correction: v_off_ini = -0.000001903 V, v_off_fin = -0.000003132 V 23:06:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407156 Vs 00:02:20 Temperature Measurement, Probe Number = 0, T = 19.959000 C 00:02:20 Temperature Measurement, Probe Number = 1, T = 20.019000 C 00:02:21 Temperature Measurement, Probe Number = 2, T = 20.019000 C 00:02:22 Temperature Measurement, Probe Number = 3, T = 19.948000 C 00:02:22 Temperature Measurement, Probe Number = 4, T = 19.998000 C 00:02:23 Temperature Measurement, Probe Number = 5, T = 19.985000 C 00:02:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:02:23 Integrated Voltage Measurement... 00:02:45 Voltage Offset Correction: v_off_ini = -0.000000424 V, v_off_fin = -0.000000234 V 00:02:45 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158460370 Vs 00:02:45 Integrated Voltage Measurement... 00:03:07 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002633 V 00:03:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427705 Vs 00:03:21 Temperature Measurement, Probe Number = 0, T = 19.972000 C 00:03:21 Temperature Measurement, Probe Number = 1, T = 20.023000 C 00:03:22 Temperature Measurement, Probe Number = 2, T = 20.020000 C 00:03:23 Temperature Measurement, Probe Number = 3, T = 19.947000 C 00:03:23 Temperature Measurement, Probe Number = 4, T = 19.998000 C 00:03:24 Temperature Measurement, Probe Number = 5, T = 19.985000 C 00:03:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:03:24 Integrated Voltage Measurement... 00:03:46 Voltage Offset Correction: v_off_ini = -0.000002143 V, v_off_fin = -0.000000944 V 00:03:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459020 Vs 00:03:46 Integrated Voltage Measurement... 00:04:08 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000002217 V 00:04:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431329 Vs 00:04:22 Temperature Measurement, Probe Number = 0, T = 19.951000 C 00:04:22 Temperature Measurement, Probe Number = 1, T = 20.021000 C 00:04:23 Temperature Measurement, Probe Number = 2, T = 20.021000 C 00:04:24 Temperature Measurement, Probe Number = 3, T = 19.945000 C 00:04:24 Temperature Measurement, Probe Number = 4, T = 19.998000 C 00:04:25 Temperature Measurement, Probe Number = 5, T = 19.984000 C 00:04:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:04:25 Integrated Voltage Measurement... 00:04:47 Voltage Offset Correction: v_off_ini = -0.000000805 V, v_off_fin = -0.000002750 V 00:04:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462298 Vs 00:04:47 Integrated Voltage Measurement... 00:05:09 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000002166 V 00:05:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426516 Vs 00:05:23 Temperature Measurement, Probe Number = 0, T = 19.950000 C 00:05:24 Temperature Measurement, Probe Number = 1, T = 20.021000 C 00:05:24 Temperature Measurement, Probe Number = 2, T = 20.019000 C 00:05:25 Temperature Measurement, Probe Number = 3, T = 19.945000 C 00:05:25 Temperature Measurement, Probe Number = 4, T = 19.996000 C 00:05:26 Temperature Measurement, Probe Number = 5, T = 19.983000 C 00:05:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:05:26 Integrated Voltage Measurement... 00:05:48 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000000432 V 00:05:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158455246 Vs 00:05:48 Integrated Voltage Measurement... 00:06:10 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000002779 V 00:06:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432220 Vs 00:06:24 Temperature Measurement, Probe Number = 0, T = 19.935000 C 00:06:25 Temperature Measurement, Probe Number = 1, T = 20.022000 C 00:06:25 Temperature Measurement, Probe Number = 2, T = 20.020000 C 00:06:26 Temperature Measurement, Probe Number = 3, T = 19.944000 C 00:06:26 Temperature Measurement, Probe Number = 4, T = 19.996000 C 00:06:27 Temperature Measurement, Probe Number = 5, T = 19.984000 C 00:06:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:06:27 Integrated Voltage Measurement... 00:06:49 Voltage Offset Correction: v_off_ini = -0.000002034 V, v_off_fin = -0.000000739 V 00:06:49 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158464473 Vs 00:06:49 Integrated Voltage Measurement... 00:07:11 Voltage Offset Correction: v_off_ini = 0.000000102 V, v_off_fin = -0.000002180 V 00:07:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439210 Vs 00:07:25 Temperature Measurement, Probe Number = 0, T = 19.921000 C 00:07:26 Temperature Measurement, Probe Number = 1, T = 20.022000 C 00:07:26 Temperature Measurement, Probe Number = 2, T = 20.019000 C 00:07:27 Temperature Measurement, Probe Number = 3, T = 19.943000 C 00:07:27 Temperature Measurement, Probe Number = 4, T = 19.997000 C 00:07:28 Temperature Measurement, Probe Number = 5, T = 19.983000 C 00:07:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:07:28 Integrated Voltage Measurement... 00:07:50 Voltage Offset Correction: v_off_ini = -0.000002355 V, v_off_fin = 0.000000644 V 00:07:50 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158441838 Vs 00:07:50 Integrated Voltage Measurement... 00:08:12 Voltage Offset Correction: v_off_ini = -0.000002443 V, v_off_fin = -0.000000468 V 00:08:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417714 Vs 00:08:26 Temperature Measurement, Probe Number = 0, T = 19.919000 C 00:08:27 Temperature Measurement, Probe Number = 1, T = 20.018000 C 00:08:27 Temperature Measurement, Probe Number = 2, T = 20.019000 C 00:08:28 Temperature Measurement, Probe Number = 3, T = 19.942000 C 00:08:29 Temperature Measurement, Probe Number = 4, T = 19.997000 C 00:08:29 Temperature Measurement, Probe Number = 5, T = 19.983000 C 00:08:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.92 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:08:29 Integrated Voltage Measurement... 00:08:52 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000000154 V 00:08:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158452801 Vs 00:08:52 Integrated Voltage Measurement... 00:09:14 Voltage Offset Correction: v_off_ini = -0.000001704 V, v_off_fin = -0.000002341 V 00:09:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158422988 Vs 00:09:28 Temperature Measurement, Probe Number = 0, T = 19.951000 C 00:09:28 Temperature Measurement, Probe Number = 1, T = 20.021000 C 00:09:29 Temperature Measurement, Probe Number = 2, T = 20.020000 C 00:09:29 Temperature Measurement, Probe Number = 3, T = 19.942000 C 00:09:30 Temperature Measurement, Probe Number = 4, T = 19.997000 C 00:09:31 Temperature Measurement, Probe Number = 5, T = 19.983000 C 00:09:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:09:31 Integrated Voltage Measurement... 00:09:53 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000000732 V 00:09:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158452791 Vs 00:09:53 Integrated Voltage Measurement... 00:10:15 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000003219 V 00:10:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158445958 Vs 00:10:29 Temperature Measurement, Probe Number = 0, T = 19.929000 C 00:10:30 Temperature Measurement, Probe Number = 1, T = 20.020000 C 00:10:30 Temperature Measurement, Probe Number = 2, T = 20.019000 C 00:10:31 Temperature Measurement, Probe Number = 3, T = 19.944000 C 00:10:31 Temperature Measurement, Probe Number = 4, T = 19.996000 C 00:10:32 Temperature Measurement, Probe Number = 5, T = 19.984000 C 00:10:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:10:32 Integrated Voltage Measurement... 00:10:54 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = 0.000002254 V 00:10:54 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158438574 Vs 00:10:54 Integrated Voltage Measurement... 00:11:16 Voltage Offset Correction: v_off_ini = -0.000002488 V, v_off_fin = -0.000002488 V 00:11:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419906 Vs 00:11:30 Temperature Measurement, Probe Number = 0, T = 19.936000 C 00:11:31 Temperature Measurement, Probe Number = 1, T = 20.023000 C 00:11:31 Temperature Measurement, Probe Number = 2, T = 20.018000 C 00:11:32 Temperature Measurement, Probe Number = 3, T = 19.944000 C 00:11:32 Temperature Measurement, Probe Number = 4, T = 19.995000 C 00:11:33 Temperature Measurement, Probe Number = 5, T = 19.985000 C 00:11:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.98 00:11:33 Integrated Voltage Measurement... 00:11:55 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = 0.000001434 V 00:11:55 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158439400 Vs 00:11:55 Integrated Voltage Measurement... 00:12:17 Voltage Offset Correction: v_off_ini = -0.000000966 V, v_off_fin = -0.000002692 V 00:12:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437104 Vs 01:08:31 Temperature Measurement, Probe Number = 0, T = 19.947000 C 01:08:32 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:08:32 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:08:33 Temperature Measurement, Probe Number = 3, T = 19.927000 C 01:08:33 Temperature Measurement, Probe Number = 4, T = 19.983000 C 01:08:34 Temperature Measurement, Probe Number = 5, T = 19.971000 C 01:08:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:08:34 Integrated Voltage Measurement... 01:08:56 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000003834 V 01:08:56 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158508739 Vs 01:08:56 Integrated Voltage Measurement... 01:09:19 Voltage Offset Correction: v_off_ini = -0.000003277 V, v_off_fin = -0.000001792 V 01:09:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434863 Vs 01:09:32 Temperature Measurement, Probe Number = 0, T = 19.966000 C 01:09:33 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:09:33 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:09:34 Temperature Measurement, Probe Number = 3, T = 19.927000 C 01:09:35 Temperature Measurement, Probe Number = 4, T = 19.982000 C 01:09:35 Temperature Measurement, Probe Number = 5, T = 19.972000 C 01:09:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:09:35 Integrated Voltage Measurement... 01:09:57 Voltage Offset Correction: v_off_ini = -0.000001595 V, v_off_fin = -0.000000944 V 01:09:57 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158470816 Vs 01:09:57 Integrated Voltage Measurement... 01:10:20 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000002283 V 01:10:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443649 Vs 01:10:34 Temperature Measurement, Probe Number = 0, T = 19.942000 C 01:10:34 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:10:35 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:10:35 Temperature Measurement, Probe Number = 3, T = 19.926000 C 01:10:36 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:10:37 Temperature Measurement, Probe Number = 5, T = 19.973000 C 01:10:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:10:37 Integrated Voltage Measurement... 01:10:59 Voltage Offset Correction: v_off_ini = -0.000002846 V, v_off_fin = -0.000002129 V 01:10:59 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158461669 Vs 01:10:59 Integrated Voltage Measurement... 01:11:21 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000002999 V 01:11:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158446736 Vs 01:11:35 Temperature Measurement, Probe Number = 0, T = 19.949000 C 01:11:35 Temperature Measurement, Probe Number = 1, T = 20.012000 C 01:11:36 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:11:37 Temperature Measurement, Probe Number = 3, T = 19.926000 C 01:11:37 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:11:38 Temperature Measurement, Probe Number = 5, T = 19.973000 C 01:11:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:11:38 Integrated Voltage Measurement... 01:12:00 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = 0.000000000 V 01:12:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158454444 Vs 01:12:01 Integrated Voltage Measurement... 01:12:23 Voltage Offset Correction: v_off_ini = 0.000000110 V, v_off_fin = -0.000003286 V 01:12:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449909 Vs 01:12:37 Temperature Measurement, Probe Number = 0, T = 19.957000 C 01:12:37 Temperature Measurement, Probe Number = 1, T = 20.012000 C 01:12:38 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:12:39 Temperature Measurement, Probe Number = 3, T = 19.927000 C 01:12:39 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:12:40 Temperature Measurement, Probe Number = 5, T = 19.972000 C 01:12:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:12:40 Integrated Voltage Measurement... 01:13:02 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000000937 V 01:13:02 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158457364 Vs 01:13:02 Integrated Voltage Measurement... 01:13:24 Voltage Offset Correction: v_off_ini = 0.000000446 V, v_off_fin = -0.000002166 V 01:13:24 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158445912 Vs 01:13:38 Temperature Measurement, Probe Number = 0, T = 19.945000 C 01:13:38 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:13:39 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:13:40 Temperature Measurement, Probe Number = 3, T = 19.926000 C 01:13:40 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:13:41 Temperature Measurement, Probe Number = 5, T = 19.973000 C 01:13:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:13:41 Integrated Voltage Measurement... 01:14:03 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001464 V 01:14:03 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158472386 Vs 01:14:03 Integrated Voltage Measurement... 01:14:26 Voltage Offset Correction: v_off_ini = -0.000001991 V, v_off_fin = -0.000002723 V 01:14:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425618 Vs 01:14:39 Temperature Measurement, Probe Number = 0, T = 19.932000 C 01:14:40 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:14:40 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:14:41 Temperature Measurement, Probe Number = 3, T = 19.925000 C 01:14:42 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:14:42 Temperature Measurement, Probe Number = 5, T = 19.973000 C 01:14:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:14:42 Integrated Voltage Measurement... 01:15:04 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = 0.000000703 V 01:15:05 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462226 Vs 01:15:05 Integrated Voltage Measurement... 01:15:27 Voltage Offset Correction: v_off_ini = 0.000000198 V, v_off_fin = -0.000000703 V 01:15:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432618 Vs 01:15:41 Temperature Measurement, Probe Number = 0, T = 19.937000 C 01:15:41 Temperature Measurement, Probe Number = 1, T = 20.010000 C 01:15:42 Temperature Measurement, Probe Number = 2, T = 20.005000 C 01:15:43 Temperature Measurement, Probe Number = 3, T = 19.925000 C 01:15:43 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:15:44 Temperature Measurement, Probe Number = 5, T = 19.972000 C 01:15:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:15:44 Integrated Voltage Measurement... 01:16:06 Voltage Offset Correction: v_off_ini = -0.000000490 V, v_off_fin = -0.000001405 V 01:16:06 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462776 Vs 01:16:06 Integrated Voltage Measurement... 01:16:29 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000002385 V 01:16:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442460 Vs 01:16:42 Temperature Measurement, Probe Number = 0, T = 19.938000 C 01:16:43 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:16:43 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:16:44 Temperature Measurement, Probe Number = 3, T = 19.926000 C 01:16:45 Temperature Measurement, Probe Number = 4, T = 19.980000 C 01:16:45 Temperature Measurement, Probe Number = 5, T = 19.971000 C 01:16:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.94 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:16:45 Integrated Voltage Measurement... 01:17:07 Voltage Offset Correction: v_off_ini = -0.000000146 V, v_off_fin = -0.000002225 V 01:17:07 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158469542 Vs 01:17:07 Integrated Voltage Measurement... 01:17:30 Voltage Offset Correction: v_off_ini = -0.000002370 V, v_off_fin = -0.000002195 V 01:17:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425866 Vs 01:17:43 Temperature Measurement, Probe Number = 0, T = 19.947000 C 01:17:44 Temperature Measurement, Probe Number = 1, T = 20.009000 C 01:17:44 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:17:45 Temperature Measurement, Probe Number = 3, T = 19.927000 C 01:17:46 Temperature Measurement, Probe Number = 4, T = 19.981000 C 01:17:46 Temperature Measurement, Probe Number = 5, T = 19.970000 C 01:17:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.93 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.97 01:17:46 Integrated Voltage Measurement... 01:18:08 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = 0.000000454 V 01:18:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158462436 Vs 01:18:09 Integrated Voltage Measurement... 01:18:31 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000002707 V 01:18:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451631 Vs 02:14:45 Temperature Measurement, Probe Number = 0, T = 19.904000 C 02:14:46 Temperature Measurement, Probe Number = 1, T = 20.002000 C 02:14:46 Temperature Measurement, Probe Number = 2, T = 19.989000 C 02:14:47 Temperature Measurement, Probe Number = 3, T = 19.910000 C 02:14:48 Temperature Measurement, Probe Number = 4, T = 19.967000 C 02:14:48 Temperature Measurement, Probe Number = 5, T = 19.964000 C 02:14:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.97 P6 = Top_Jaw, Value = 19.96 02:14:48 Integrated Voltage Measurement... 02:15:10 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = 0.000001222 V 02:15:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158453122 Vs 02:15:11 Integrated Voltage Measurement... 02:15:33 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002122 V 02:15:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420646 Vs 02:15:46 Temperature Measurement, Probe Number = 0, T = 19.882000 C 02:15:47 Temperature Measurement, Probe Number = 1, T = 19.999000 C 02:15:48 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:15:48 Temperature Measurement, Probe Number = 3, T = 19.910000 C 02:15:49 Temperature Measurement, Probe Number = 4, T = 19.966000 C 02:15:49 Temperature Measurement, Probe Number = 5, T = 19.961000 C 02:15:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.97 P6 = Top_Jaw, Value = 19.96 02:15:49 Integrated Voltage Measurement... 02:16:12 Voltage Offset Correction: v_off_ini = -0.000002137 V, v_off_fin = 0.000000081 V 02:16:12 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158423381 Vs 02:16:12 Integrated Voltage Measurement... 02:16:34 Voltage Offset Correction: v_off_ini = -0.000002085 V, v_off_fin = -0.000001178 V 02:16:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415548 Vs 02:16:48 Temperature Measurement, Probe Number = 0, T = 19.846000 C 02:16:48 Temperature Measurement, Probe Number = 1, T = 19.999000 C 02:16:49 Temperature Measurement, Probe Number = 2, T = 19.985000 C 02:16:50 Temperature Measurement, Probe Number = 3, T = 19.908000 C 02:16:50 Temperature Measurement, Probe Number = 4, T = 19.967000 C 02:16:51 Temperature Measurement, Probe Number = 5, T = 19.960000 C 02:16:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.85 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.97 P6 = Top_Jaw, Value = 19.96 02:16:51 Integrated Voltage Measurement... 02:17:13 Voltage Offset Correction: v_off_ini = -0.000002115 V, v_off_fin = -0.000000527 V 02:17:13 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158442673 Vs 02:17:13 Integrated Voltage Measurement... 02:17:35 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000002810 V 02:17:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158433990 Vs 02:17:49 Temperature Measurement, Probe Number = 0, T = 19.801000 C 02:17:50 Temperature Measurement, Probe Number = 1, T = 19.999000 C 02:17:50 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:17:51 Temperature Measurement, Probe Number = 3, T = 19.905000 C 02:17:52 Temperature Measurement, Probe Number = 4, T = 19.966000 C 02:17:52 Temperature Measurement, Probe Number = 5, T = 19.960000 C 02:17:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.80 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.97 P6 = Top_Jaw, Value = 19.96 02:17:52 Integrated Voltage Measurement... 02:18:14 Voltage Offset Correction: v_off_ini = -0.000002049 V, v_off_fin = -0.000000761 V 02:18:14 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158444151 Vs 02:18:14 Integrated Voltage Measurement... 02:18:36 Voltage Offset Correction: v_off_ini = -0.000000095 V, v_off_fin = -0.000002927 V 02:18:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435999 Vs 02:18:50 Temperature Measurement, Probe Number = 0, T = 19.771000 C 02:18:51 Temperature Measurement, Probe Number = 1, T = 19.998000 C 02:18:51 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:18:52 Temperature Measurement, Probe Number = 3, T = 19.905000 C 02:18:53 Temperature Measurement, Probe Number = 4, T = 19.964000 C 02:18:53 Temperature Measurement, Probe Number = 5, T = 19.961000 C 02:18:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:18:53 Integrated Voltage Measurement... 02:19:15 Voltage Offset Correction: v_off_ini = -0.000002063 V, v_off_fin = -0.000001631 V 02:19:16 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158454320 Vs 02:19:16 Integrated Voltage Measurement... 02:19:38 Voltage Offset Correction: v_off_ini = -0.000000556 V, v_off_fin = -0.000001726 V 02:19:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430444 Vs 02:19:52 Temperature Measurement, Probe Number = 0, T = 19.764000 C 02:19:52 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:19:53 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:19:54 Temperature Measurement, Probe Number = 3, T = 19.905000 C 02:19:54 Temperature Measurement, Probe Number = 4, T = 19.964000 C 02:19:55 Temperature Measurement, Probe Number = 5, T = 19.962000 C 02:19:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:19:55 Integrated Voltage Measurement... 02:20:17 Voltage Offset Correction: v_off_ini = -0.000002019 V, v_off_fin = -0.000001141 V 02:20:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158453533 Vs 02:20:17 Integrated Voltage Measurement... 02:20:40 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = -0.000001163 V 02:20:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426214 Vs 02:20:53 Temperature Measurement, Probe Number = 0, T = 19.761000 C 02:20:54 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:20:54 Temperature Measurement, Probe Number = 2, T = 19.989000 C 02:20:55 Temperature Measurement, Probe Number = 3, T = 19.905000 C 02:20:56 Temperature Measurement, Probe Number = 4, T = 19.964000 C 02:20:56 Temperature Measurement, Probe Number = 5, T = 19.961000 C 02:20:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:20:56 Integrated Voltage Measurement... 02:21:18 Voltage Offset Correction: v_off_ini = -0.000001573 V, v_off_fin = -0.000000893 V 02:21:18 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158435644 Vs 02:21:18 Integrated Voltage Measurement... 02:21:41 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = -0.000002085 V 02:21:41 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158413741 Vs 02:21:54 Temperature Measurement, Probe Number = 0, T = 19.767000 C 02:21:55 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:21:55 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:21:56 Temperature Measurement, Probe Number = 3, T = 19.905000 C 02:21:57 Temperature Measurement, Probe Number = 4, T = 19.963000 C 02:21:57 Temperature Measurement, Probe Number = 5, T = 19.962000 C 02:21:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:21:57 Integrated Voltage Measurement... 02:22:19 Voltage Offset Correction: v_off_ini = -0.000001939 V, v_off_fin = -0.000000658 V 02:22:19 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158432945 Vs 02:22:19 Integrated Voltage Measurement... 02:22:41 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = -0.000002691 V 02:22:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432797 Vs 02:22:55 Temperature Measurement, Probe Number = 0, T = 19.789000 C 02:22:56 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:22:56 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:22:57 Temperature Measurement, Probe Number = 3, T = 19.907000 C 02:22:58 Temperature Measurement, Probe Number = 4, T = 19.965000 C 02:22:58 Temperature Measurement, Probe Number = 5, T = 19.962000 C 02:22:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.79 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:22:58 Integrated Voltage Measurement... 02:23:20 Voltage Offset Correction: v_off_ini = -0.000000102 V, v_off_fin = -0.000000739 V 02:23:20 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158428837 Vs 02:23:20 Integrated Voltage Measurement... 02:23:43 Voltage Offset Correction: v_off_ini = -0.000001419 V, v_off_fin = -0.000002077 V 02:23:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413826 Vs 02:23:57 Temperature Measurement, Probe Number = 0, T = 19.841000 C 02:23:57 Temperature Measurement, Probe Number = 1, T = 19.999000 C 02:23:58 Temperature Measurement, Probe Number = 2, T = 19.986000 C 02:23:59 Temperature Measurement, Probe Number = 3, T = 19.906000 C 02:23:59 Temperature Measurement, Probe Number = 4, T = 19.964000 C 02:24:00 Temperature Measurement, Probe Number = 5, T = 19.962000 C 02:24:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.91 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.96 02:24:00 Integrated Voltage Measurement... 02:24:22 Voltage Offset Correction: v_off_ini = -0.000001953 V, v_off_fin = -0.000002004 V 02:24:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442827 Vs 02:24:22 Integrated Voltage Measurement... 02:24:44 Voltage Offset Correction: v_off_ini = -0.000000110 V, v_off_fin = -0.000001148 V 02:24:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418736 Vs 03:20:58 Temperature Measurement, Probe Number = 0, T = 19.788000 C 03:20:58 Temperature Measurement, Probe Number = 1, T = 19.985000 C 03:20:59 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:21:00 Temperature Measurement, Probe Number = 3, T = 19.886000 C 03:21:00 Temperature Measurement, Probe Number = 4, T = 19.948000 C 03:21:01 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:21:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.79 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:21:01 Integrated Voltage Measurement... 03:21:23 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000000731 V 03:21:23 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158469963 Vs 03:21:23 Integrated Voltage Measurement... 03:21:46 Voltage Offset Correction: v_off_ini = 0.000001214 V, v_off_fin = -0.000001229 V 03:21:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436378 Vs 03:21:59 Temperature Measurement, Probe Number = 0, T = 19.761000 C 03:22:00 Temperature Measurement, Probe Number = 1, T = 19.987000 C 03:22:00 Temperature Measurement, Probe Number = 2, T = 19.968000 C 03:22:01 Temperature Measurement, Probe Number = 3, T = 19.886000 C 03:22:02 Temperature Measurement, Probe Number = 4, T = 19.947000 C 03:22:02 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:22:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:22:02 Integrated Voltage Measurement... 03:22:24 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000000293 V 03:22:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158454186 Vs 03:22:24 Integrated Voltage Measurement... 03:22:47 Voltage Offset Correction: v_off_ini = -0.000002699 V, v_off_fin = -0.000002524 V 03:22:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158399458 Vs 03:23:00 Temperature Measurement, Probe Number = 0, T = 19.750000 C 03:23:01 Temperature Measurement, Probe Number = 1, T = 19.984000 C 03:23:01 Temperature Measurement, Probe Number = 2, T = 19.971000 C 03:23:02 Temperature Measurement, Probe Number = 3, T = 19.886000 C 03:23:03 Temperature Measurement, Probe Number = 4, T = 19.946000 C 03:23:03 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:23:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.75 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:23:03 Integrated Voltage Measurement... 03:23:25 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000000059 V 03:23:25 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158435695 Vs 03:23:25 Integrated Voltage Measurement... 03:23:48 Voltage Offset Correction: v_off_ini = -0.000000198 V, v_off_fin = -0.000002260 V 03:23:48 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158426177 Vs 03:24:01 Temperature Measurement, Probe Number = 0, T = 19.743000 C 03:24:02 Temperature Measurement, Probe Number = 1, T = 19.987000 C 03:24:02 Temperature Measurement, Probe Number = 2, T = 19.972000 C 03:24:03 Temperature Measurement, Probe Number = 3, T = 19.886000 C 03:24:04 Temperature Measurement, Probe Number = 4, T = 19.947000 C 03:24:04 Temperature Measurement, Probe Number = 5, T = 19.948000 C 03:24:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:24:04 Integrated Voltage Measurement... 03:24:26 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = 0.000001214 V 03:24:27 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158417555 Vs 03:24:27 Integrated Voltage Measurement... 03:24:49 Voltage Offset Correction: v_off_ini = -0.000000110 V, v_off_fin = -0.000001222 V 03:24:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438257 Vs 03:25:03 Temperature Measurement, Probe Number = 0, T = 19.723000 C 03:25:03 Temperature Measurement, Probe Number = 1, T = 19.985000 C 03:25:04 Temperature Measurement, Probe Number = 2, T = 19.972000 C 03:25:04 Temperature Measurement, Probe Number = 3, T = 19.884000 C 03:25:05 Temperature Measurement, Probe Number = 4, T = 19.946000 C 03:25:06 Temperature Measurement, Probe Number = 5, T = 19.946000 C 03:25:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.72 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:25:06 Integrated Voltage Measurement... 03:25:28 Voltage Offset Correction: v_off_ini = -0.000002407 V, v_off_fin = -0.000003753 V 03:25:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453187 Vs 03:25:28 Integrated Voltage Measurement... 03:25:50 Voltage Offset Correction: v_off_ini = -0.000002744 V, v_off_fin = -0.000003395 V 03:25:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397329 Vs 03:26:04 Temperature Measurement, Probe Number = 0, T = 19.728000 C 03:26:04 Temperature Measurement, Probe Number = 1, T = 19.989000 C 03:26:05 Temperature Measurement, Probe Number = 2, T = 19.973000 C 03:26:05 Temperature Measurement, Probe Number = 3, T = 19.883000 C 03:26:06 Temperature Measurement, Probe Number = 4, T = 19.948000 C 03:26:07 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:26:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.73 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:26:07 Integrated Voltage Measurement... 03:26:29 Voltage Offset Correction: v_off_ini = -0.000000783 V, v_off_fin = -0.000001258 V 03:26:29 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158449491 Vs 03:26:29 Integrated Voltage Measurement... 03:26:51 Voltage Offset Correction: v_off_ini = -0.000000007 V, v_off_fin = -0.000002795 V 03:26:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438141 Vs 03:27:05 Temperature Measurement, Probe Number = 0, T = 19.755000 C 03:27:06 Temperature Measurement, Probe Number = 1, T = 19.991000 C 03:27:06 Temperature Measurement, Probe Number = 2, T = 19.972000 C 03:27:07 Temperature Measurement, Probe Number = 3, T = 19.884000 C 03:27:07 Temperature Measurement, Probe Number = 4, T = 19.947000 C 03:27:08 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:27:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.75 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:27:08 Integrated Voltage Measurement... 03:27:30 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001339 V 03:27:30 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158448053 Vs 03:27:30 Integrated Voltage Measurement... 03:27:52 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000002546 V 03:27:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419985 Vs 03:28:06 Temperature Measurement, Probe Number = 0, T = 19.777000 C 03:28:07 Temperature Measurement, Probe Number = 1, T = 19.990000 C 03:28:07 Temperature Measurement, Probe Number = 2, T = 19.971000 C 03:28:08 Temperature Measurement, Probe Number = 3, T = 19.884000 C 03:28:08 Temperature Measurement, Probe Number = 4, T = 19.947000 C 03:28:09 Temperature Measurement, Probe Number = 5, T = 19.949000 C 03:28:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.78 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:28:09 Integrated Voltage Measurement... 03:28:31 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000001236 V 03:28:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158448540 Vs 03:28:32 Integrated Voltage Measurement... 03:28:54 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = -0.000003365 V 03:28:54 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158426862 Vs 03:29:08 Temperature Measurement, Probe Number = 0, T = 19.753000 C 03:29:08 Temperature Measurement, Probe Number = 1, T = 19.986000 C 03:29:09 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:29:10 Temperature Measurement, Probe Number = 3, T = 19.882000 C 03:29:10 Temperature Measurement, Probe Number = 4, T = 19.943000 C 03:29:11 Temperature Measurement, Probe Number = 5, T = 19.948000 C 03:29:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.75 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.95 03:29:11 Integrated Voltage Measurement... 03:29:33 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = 0.000000029 V 03:29:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442562 Vs 03:29:33 Integrated Voltage Measurement... 03:29:55 Voltage Offset Correction: v_off_ini = -0.000002926 V, v_off_fin = -0.000002151 V 03:29:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395345 Vs 03:30:09 Temperature Measurement, Probe Number = 0, T = 19.741000 C 03:30:09 Temperature Measurement, Probe Number = 1, T = 19.986000 C 03:30:10 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:30:11 Temperature Measurement, Probe Number = 3, T = 19.881000 C 03:30:11 Temperature Measurement, Probe Number = 4, T = 19.945000 C 03:30:12 Temperature Measurement, Probe Number = 5, T = 19.948000 C 03:30:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 19.97 P4 = Encode_Arm, Value = 19.88 P5 = Bottom_Jaw, Value = 19.95 P6 = Top_Jaw, Value = 19.95 03:30:12 Integrated Voltage Measurement... 03:30:34 Voltage Offset Correction: v_off_ini = -0.000001382 V, v_off_fin = -0.000001551 V 03:30:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453582 Vs 03:30:34 Integrated Voltage Measurement... 03:30:56 Voltage Offset Correction: v_off_ini = 0.000000958 V, v_off_fin = -0.000001317 V 03:30:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442039 Vs 04:27:10 Temperature Measurement, Probe Number = 0, T = 19.789000 C 04:27:11 Temperature Measurement, Probe Number = 1, T = 19.969000 C 04:27:11 Temperature Measurement, Probe Number = 2, T = 19.946000 C 04:27:12 Temperature Measurement, Probe Number = 3, T = 19.858000 C 04:27:12 Temperature Measurement, Probe Number = 4, T = 19.924000 C 04:27:13 Temperature Measurement, Probe Number = 5, T = 19.932000 C 04:27:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.79 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:27:13 Integrated Voltage Measurement... 04:27:35 Voltage Offset Correction: v_off_ini = -0.000000095 V, v_off_fin = -0.000001325 V 04:27:35 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158462711 Vs 04:27:35 Integrated Voltage Measurement... 04:27:57 Voltage Offset Correction: v_off_ini = -0.000000425 V, v_off_fin = -0.000001054 V 04:27:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413475 Vs 04:28:11 Temperature Measurement, Probe Number = 0, T = 19.777000 C 04:28:12 Temperature Measurement, Probe Number = 1, T = 19.970000 C 04:28:12 Temperature Measurement, Probe Number = 2, T = 19.948000 C 04:28:13 Temperature Measurement, Probe Number = 3, T = 19.857000 C 04:28:13 Temperature Measurement, Probe Number = 4, T = 19.923000 C 04:28:14 Temperature Measurement, Probe Number = 5, T = 19.929000 C 04:28:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.78 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:28:14 Integrated Voltage Measurement... 04:28:36 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000001230 V 04:28:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453080 Vs 04:28:36 Integrated Voltage Measurement... 04:28:58 Voltage Offset Correction: v_off_ini = -0.000000242 V, v_off_fin = -0.000003236 V 04:28:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425042 Vs 04:29:12 Temperature Measurement, Probe Number = 0, T = 19.756000 C 04:29:13 Temperature Measurement, Probe Number = 1, T = 19.961000 C 04:29:13 Temperature Measurement, Probe Number = 2, T = 19.940000 C 04:29:14 Temperature Measurement, Probe Number = 3, T = 19.856000 C 04:29:15 Temperature Measurement, Probe Number = 4, T = 19.921000 C 04:29:15 Temperature Measurement, Probe Number = 5, T = 19.929000 C 04:29:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.76 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:29:15 Integrated Voltage Measurement... 04:29:37 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000000893 V 04:29:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158441524 Vs 04:29:38 Integrated Voltage Measurement... 04:30:00 Voltage Offset Correction: v_off_ini = -0.000000666 V, v_off_fin = -0.000003689 V 04:30:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412651 Vs 04:30:13 Temperature Measurement, Probe Number = 0, T = 19.770000 C 04:30:14 Temperature Measurement, Probe Number = 1, T = 19.964000 C 04:30:14 Temperature Measurement, Probe Number = 2, T = 19.940000 C 04:30:15 Temperature Measurement, Probe Number = 3, T = 19.855000 C 04:30:16 Temperature Measurement, Probe Number = 4, T = 19.922000 C 04:30:16 Temperature Measurement, Probe Number = 5, T = 19.930000 C 04:30:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.77 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:30:16 Integrated Voltage Measurement... 04:30:38 Voltage Offset Correction: v_off_ini = -0.000002613 V, v_off_fin = -0.000001991 V 04:30:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158449659 Vs 04:30:39 Integrated Voltage Measurement... 04:31:01 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000002020 V 04:31:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417390 Vs 04:31:15 Temperature Measurement, Probe Number = 0, T = 19.751000 C 04:31:15 Temperature Measurement, Probe Number = 1, T = 19.966000 C 04:31:16 Temperature Measurement, Probe Number = 2, T = 19.943000 C 04:31:17 Temperature Measurement, Probe Number = 3, T = 19.854000 C 04:31:17 Temperature Measurement, Probe Number = 4, T = 19.921000 C 04:31:18 Temperature Measurement, Probe Number = 5, T = 19.929000 C 04:31:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.75 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:31:18 Integrated Voltage Measurement... 04:31:40 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = -0.000000476 V 04:31:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158438434 Vs 04:31:40 Integrated Voltage Measurement... 04:32:02 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000003073 V 04:32:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158414990 Vs 04:32:16 Temperature Measurement, Probe Number = 0, T = 19.736000 C 04:32:16 Temperature Measurement, Probe Number = 1, T = 19.967000 C 04:32:17 Temperature Measurement, Probe Number = 2, T = 19.944000 C 04:32:18 Temperature Measurement, Probe Number = 3, T = 19.854000 C 04:32:18 Temperature Measurement, Probe Number = 4, T = 19.920000 C 04:32:19 Temperature Measurement, Probe Number = 5, T = 19.930000 C 04:32:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.74 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:32:19 Integrated Voltage Measurement... 04:32:41 Voltage Offset Correction: v_off_ini = -0.000000995 V, v_off_fin = -0.000000293 V 04:32:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158434738 Vs 04:32:41 Integrated Voltage Measurement... 04:33:11 Voltage Offset Correction: v_off_ini = 0.000000395 V, v_off_fin = -0.000000447 V 04:33:11 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158428505 Vs 04:33:25 Temperature Measurement, Probe Number = 0, T = 19.729000 C 04:33:25 Temperature Measurement, Probe Number = 1, T = 19.966000 C 04:33:26 Temperature Measurement, Probe Number = 2, T = 19.945000 C 04:33:27 Temperature Measurement, Probe Number = 3, T = 19.853000 C 04:33:27 Temperature Measurement, Probe Number = 4, T = 19.920000 C 04:33:28 Temperature Measurement, Probe Number = 5, T = 19.929000 C 04:33:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.73 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:33:28 Integrated Voltage Measurement... 04:33:50 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001083 V 04:33:50 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158423970 Vs 04:33:50 Integrated Voltage Measurement... 04:34:12 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000002276 V 04:34:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424716 Vs 04:34:26 Temperature Measurement, Probe Number = 0, T = 19.719000 C 04:34:26 Temperature Measurement, Probe Number = 1, T = 19.962000 C 04:34:27 Temperature Measurement, Probe Number = 2, T = 19.942000 C 04:34:28 Temperature Measurement, Probe Number = 3, T = 19.853000 C 04:34:28 Temperature Measurement, Probe Number = 4, T = 19.919000 C 04:34:29 Temperature Measurement, Probe Number = 5, T = 19.926000 C 04:34:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.72 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:34:29 Integrated Voltage Measurement... 04:34:51 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000827 V 04:34:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158433688 Vs 04:34:51 Integrated Voltage Measurement... 04:35:13 Voltage Offset Correction: v_off_ini = -0.000001522 V, v_off_fin = -0.000002364 V 04:35:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158417211 Vs 04:35:27 Temperature Measurement, Probe Number = 0, T = 19.689000 C 04:35:27 Temperature Measurement, Probe Number = 1, T = 19.964000 C 04:35:28 Temperature Measurement, Probe Number = 2, T = 19.941000 C 04:35:29 Temperature Measurement, Probe Number = 3, T = 19.850000 C 04:35:29 Temperature Measurement, Probe Number = 4, T = 19.918000 C 04:35:30 Temperature Measurement, Probe Number = 5, T = 19.927000 C 04:35:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:35:30 Integrated Voltage Measurement... 04:35:52 Voltage Offset Correction: v_off_ini = -0.000001873 V, v_off_fin = -0.000002473 V 04:35:52 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462415 Vs 04:35:52 Integrated Voltage Measurement... 04:36:14 Voltage Offset Correction: v_off_ini = -0.000001142 V, v_off_fin = -0.000003059 V 04:36:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423621 Vs 04:36:28 Temperature Measurement, Probe Number = 0, T = 19.667000 C 04:36:28 Temperature Measurement, Probe Number = 1, T = 19.964000 C 04:36:29 Temperature Measurement, Probe Number = 2, T = 19.941000 C 04:36:30 Temperature Measurement, Probe Number = 3, T = 19.850000 C 04:36:30 Temperature Measurement, Probe Number = 4, T = 19.918000 C 04:36:31 Temperature Measurement, Probe Number = 5, T = 19.928000 C 04:36:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.67 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.93 04:36:31 Integrated Voltage Measurement... 04:36:53 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000000373 V 04:36:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158443800 Vs 04:36:53 Integrated Voltage Measurement... 04:37:15 Voltage Offset Correction: v_off_ini = -0.000000981 V, v_off_fin = -0.000002876 V 04:37:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418054 Vs 05:33:29 Temperature Measurement, Probe Number = 0, T = 19.508000 C 05:33:29 Temperature Measurement, Probe Number = 1, T = 19.934000 C 05:33:30 Temperature Measurement, Probe Number = 2, T = 19.910000 C 05:33:31 Temperature Measurement, Probe Number = 3, T = 19.813000 C 05:33:31 Temperature Measurement, Probe Number = 4, T = 19.890000 C 05:33:32 Temperature Measurement, Probe Number = 5, T = 19.902000 C 05:33:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.51 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:33:32 Integrated Voltage Measurement... 05:33:54 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = 0.000001250 V 05:33:54 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158453128 Vs 05:33:54 Integrated Voltage Measurement... 05:34:16 Voltage Offset Correction: v_off_ini = -0.000000212 V, v_off_fin = -0.000002018 V 05:34:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424302 Vs 05:34:30 Temperature Measurement, Probe Number = 0, T = 19.507000 C 05:34:30 Temperature Measurement, Probe Number = 1, T = 19.937000 C 05:34:31 Temperature Measurement, Probe Number = 2, T = 19.911000 C 05:34:32 Temperature Measurement, Probe Number = 3, T = 19.813000 C 05:34:32 Temperature Measurement, Probe Number = 4, T = 19.889000 C 05:34:33 Temperature Measurement, Probe Number = 5, T = 19.903000 C 05:34:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.51 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:34:33 Integrated Voltage Measurement... 05:34:55 Voltage Offset Correction: v_off_ini = -0.000001543 V, v_off_fin = -0.000000475 V 05:34:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442472 Vs 05:34:55 Integrated Voltage Measurement... 05:35:18 Voltage Offset Correction: v_off_ini = -0.000001082 V, v_off_fin = -0.000003166 V 05:35:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418675 Vs 05:35:32 Temperature Measurement, Probe Number = 0, T = 19.503000 C 05:35:32 Temperature Measurement, Probe Number = 1, T = 19.934000 C 05:35:33 Temperature Measurement, Probe Number = 2, T = 19.913000 C 05:35:33 Temperature Measurement, Probe Number = 3, T = 19.812000 C 05:35:34 Temperature Measurement, Probe Number = 4, T = 19.889000 C 05:35:35 Temperature Measurement, Probe Number = 5, T = 19.900000 C 05:35:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.50 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:35:35 Integrated Voltage Measurement... 05:35:57 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = 0.000000366 V 05:35:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422485 Vs 05:35:57 Integrated Voltage Measurement... 05:36:19 Voltage Offset Correction: v_off_ini = -0.000000724 V, v_off_fin = -0.000002801 V 05:36:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423969 Vs 05:36:33 Temperature Measurement, Probe Number = 0, T = 19.503000 C 05:36:33 Temperature Measurement, Probe Number = 1, T = 19.937000 C 05:36:34 Temperature Measurement, Probe Number = 2, T = 19.914000 C 05:36:35 Temperature Measurement, Probe Number = 3, T = 19.812000 C 05:36:35 Temperature Measurement, Probe Number = 4, T = 19.888000 C 05:36:36 Temperature Measurement, Probe Number = 5, T = 19.900000 C 05:36:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.50 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:36:36 Integrated Voltage Measurement... 05:36:58 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000000827 V 05:36:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158441268 Vs 05:36:58 Integrated Voltage Measurement... 05:37:20 Voltage Offset Correction: v_off_ini = -0.000000936 V, v_off_fin = -0.000001939 V 05:37:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415224 Vs 05:37:34 Temperature Measurement, Probe Number = 0, T = 19.503000 C 05:37:34 Temperature Measurement, Probe Number = 1, T = 19.934000 C 05:37:35 Temperature Measurement, Probe Number = 2, T = 19.913000 C 05:37:36 Temperature Measurement, Probe Number = 3, T = 19.811000 C 05:37:36 Temperature Measurement, Probe Number = 4, T = 19.887000 C 05:37:37 Temperature Measurement, Probe Number = 5, T = 19.899000 C 05:37:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.50 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:37:37 Integrated Voltage Measurement... 05:37:59 Voltage Offset Correction: v_off_ini = -0.000001682 V, v_off_fin = -0.000001126 V 05:37:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425774 Vs 05:37:59 Integrated Voltage Measurement... 05:38:22 Voltage Offset Correction: v_off_ini = -0.000001346 V, v_off_fin = -0.000002721 V 05:38:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158404917 Vs 05:38:35 Temperature Measurement, Probe Number = 0, T = 19.493000 C 05:38:36 Temperature Measurement, Probe Number = 1, T = 19.933000 C 05:38:36 Temperature Measurement, Probe Number = 2, T = 19.910000 C 05:38:37 Temperature Measurement, Probe Number = 3, T = 19.811000 C 05:38:38 Temperature Measurement, Probe Number = 4, T = 19.888000 C 05:38:38 Temperature Measurement, Probe Number = 5, T = 19.900000 C 05:38:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.49 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:38:38 Integrated Voltage Measurement... 05:39:00 Voltage Offset Correction: v_off_ini = -0.000001360 V, v_off_fin = -0.000001053 V 05:39:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158429358 Vs 05:39:00 Integrated Voltage Measurement... 05:39:22 Voltage Offset Correction: v_off_ini = -0.000000834 V, v_off_fin = -0.000002296 V 05:39:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158412845 Vs 05:39:36 Temperature Measurement, Probe Number = 0, T = 19.513000 C 05:39:37 Temperature Measurement, Probe Number = 1, T = 19.937000 C 05:39:37 Temperature Measurement, Probe Number = 2, T = 19.911000 C 05:39:38 Temperature Measurement, Probe Number = 3, T = 19.811000 C 05:39:38 Temperature Measurement, Probe Number = 4, T = 19.888000 C 05:39:39 Temperature Measurement, Probe Number = 5, T = 19.901000 C 05:39:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.51 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:39:39 Integrated Voltage Measurement... 05:40:01 Voltage Offset Correction: v_off_ini = -0.000001697 V, v_off_fin = -0.000000827 V 05:40:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446631 Vs 05:40:01 Integrated Voltage Measurement... 05:40:24 Voltage Offset Correction: v_off_ini = -0.000000651 V, v_off_fin = -0.000001682 V 05:40:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158406629 Vs 05:40:37 Temperature Measurement, Probe Number = 0, T = 19.526000 C 05:40:38 Temperature Measurement, Probe Number = 1, T = 19.937000 C 05:40:38 Temperature Measurement, Probe Number = 2, T = 19.911000 C 05:40:39 Temperature Measurement, Probe Number = 3, T = 19.810000 C 05:40:40 Temperature Measurement, Probe Number = 4, T = 19.887000 C 05:40:40 Temperature Measurement, Probe Number = 5, T = 19.902000 C 05:40:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.53 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:40:40 Integrated Voltage Measurement... 05:41:02 Voltage Offset Correction: v_off_ini = -0.000002399 V, v_off_fin = -0.000000907 V 05:41:02 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158458572 Vs 05:41:02 Integrated Voltage Measurement... 05:41:25 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = -0.000002428 V 05:41:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403705 Vs 05:41:38 Temperature Measurement, Probe Number = 0, T = 19.532000 C 05:41:39 Temperature Measurement, Probe Number = 1, T = 19.936000 C 05:41:39 Temperature Measurement, Probe Number = 2, T = 19.912000 C 05:41:40 Temperature Measurement, Probe Number = 3, T = 19.810000 C 05:41:41 Temperature Measurement, Probe Number = 4, T = 19.887000 C 05:41:41 Temperature Measurement, Probe Number = 5, T = 19.900000 C 05:41:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.53 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:41:41 Integrated Voltage Measurement... 05:42:03 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000000834 V 05:42:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158433459 Vs 05:42:03 Integrated Voltage Measurement... 05:42:26 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = -0.000002984 V 05:42:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158415107 Vs 05:42:40 Temperature Measurement, Probe Number = 0, T = 19.519000 C 05:42:40 Temperature Measurement, Probe Number = 1, T = 19.934000 C 05:42:41 Temperature Measurement, Probe Number = 2, T = 19.908000 C 05:42:42 Temperature Measurement, Probe Number = 3, T = 19.808000 C 05:42:42 Temperature Measurement, Probe Number = 4, T = 19.886000 C 05:42:43 Temperature Measurement, Probe Number = 5, T = 19.899000 C 05:42:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.52 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.91 P4 = Encode_Arm, Value = 19.81 P5 = Bottom_Jaw, Value = 19.89 P6 = Top_Jaw, Value = 19.90 05:42:43 Integrated Voltage Measurement... 05:43:05 Voltage Offset Correction: v_off_ini = -0.000001265 V, v_off_fin = -0.000000468 V 05:43:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158433764 Vs 05:43:05 Integrated Voltage Measurement... 05:43:27 Voltage Offset Correction: v_off_ini = -0.000001199 V, v_off_fin = -0.000002428 V 05:43:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158405970 Vs 06:39:41 Temperature Measurement, Probe Number = 0, T = 19.533000 C 06:39:41 Temperature Measurement, Probe Number = 1, T = 19.911000 C 06:39:42 Temperature Measurement, Probe Number = 2, T = 19.886000 C 06:39:43 Temperature Measurement, Probe Number = 3, T = 19.786000 C 06:39:43 Temperature Measurement, Probe Number = 4, T = 19.862000 C 06:39:44 Temperature Measurement, Probe Number = 5, T = 19.875000 C 06:39:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.53 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.88 06:39:44 Integrated Voltage Measurement... 06:40:06 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = 0.000002276 V 06:40:06 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158431792 Vs 06:40:06 Integrated Voltage Measurement... 06:40:28 Voltage Offset Correction: v_off_ini = 0.000000776 V, v_off_fin = -0.000001712 V 06:40:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424277 Vs 06:40:42 Temperature Measurement, Probe Number = 0, T = 19.524000 C 06:40:43 Temperature Measurement, Probe Number = 1, T = 19.906000 C 06:40:43 Temperature Measurement, Probe Number = 2, T = 19.884000 C 06:40:44 Temperature Measurement, Probe Number = 3, T = 19.787000 C 06:40:45 Temperature Measurement, Probe Number = 4, T = 19.862000 C 06:40:45 Temperature Measurement, Probe Number = 5, T = 19.873000 C 06:40:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.52 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:40:45 Integrated Voltage Measurement... 06:41:07 Voltage Offset Correction: v_off_ini = -0.000001969 V, v_off_fin = 0.000000198 V 06:41:07 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425984 Vs 06:41:08 Integrated Voltage Measurement... 06:41:30 Voltage Offset Correction: v_off_ini = -0.000000220 V, v_off_fin = -0.000001405 V 06:41:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425611 Vs 06:41:44 Temperature Measurement, Probe Number = 0, T = 19.523000 C 06:41:44 Temperature Measurement, Probe Number = 1, T = 19.909000 C 06:41:45 Temperature Measurement, Probe Number = 2, T = 19.886000 C 06:41:45 Temperature Measurement, Probe Number = 3, T = 19.788000 C 06:41:46 Temperature Measurement, Probe Number = 4, T = 19.861000 C 06:41:47 Temperature Measurement, Probe Number = 5, T = 19.873000 C 06:41:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.52 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:41:47 Integrated Voltage Measurement... 06:42:09 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000000659 V 06:42:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158428120 Vs 06:42:09 Integrated Voltage Measurement... 06:42:31 Voltage Offset Correction: v_off_ini = -0.000000820 V, v_off_fin = -0.000003022 V 06:42:31 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158411785 Vs 06:42:45 Temperature Measurement, Probe Number = 0, T = 19.526000 C 06:42:45 Temperature Measurement, Probe Number = 1, T = 19.912000 C 06:42:46 Temperature Measurement, Probe Number = 2, T = 19.889000 C 06:42:47 Temperature Measurement, Probe Number = 3, T = 19.788000 C 06:42:47 Temperature Measurement, Probe Number = 4, T = 19.860000 C 06:42:48 Temperature Measurement, Probe Number = 5, T = 19.871000 C 06:42:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.53 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:42:48 Integrated Voltage Measurement... 06:43:10 Voltage Offset Correction: v_off_ini = -0.000000805 V, v_off_fin = -0.000000234 V 06:43:10 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158418809 Vs 06:43:10 Integrated Voltage Measurement... 06:43:32 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = -0.000003601 V 06:43:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407545 Vs 06:43:46 Temperature Measurement, Probe Number = 0, T = 19.525000 C 06:43:46 Temperature Measurement, Probe Number = 1, T = 19.910000 C 06:43:47 Temperature Measurement, Probe Number = 2, T = 19.881000 C 06:43:48 Temperature Measurement, Probe Number = 3, T = 19.789000 C 06:43:48 Temperature Measurement, Probe Number = 4, T = 19.861000 C 06:43:49 Temperature Measurement, Probe Number = 5, T = 19.871000 C 06:43:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.52 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:43:49 Integrated Voltage Measurement... 06:44:11 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000001200 V 06:44:11 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158422007 Vs 06:44:11 Integrated Voltage Measurement... 06:44:33 Voltage Offset Correction: v_off_ini = -0.000001215 V, v_off_fin = -0.000002583 V 06:44:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386048 Vs 06:44:47 Temperature Measurement, Probe Number = 0, T = 19.566000 C 06:44:47 Temperature Measurement, Probe Number = 1, T = 19.904000 C 06:44:48 Temperature Measurement, Probe Number = 2, T = 19.880000 C 06:44:49 Temperature Measurement, Probe Number = 3, T = 19.784000 C 06:44:49 Temperature Measurement, Probe Number = 4, T = 19.861000 C 06:44:50 Temperature Measurement, Probe Number = 5, T = 19.871000 C 06:44:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:44:50 Integrated Voltage Measurement... 06:45:12 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000000542 V 06:45:12 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158431264 Vs 06:45:12 Integrated Voltage Measurement... 06:45:35 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000002144 V 06:45:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158401491 Vs 06:45:49 Temperature Measurement, Probe Number = 0, T = 19.575000 C 06:45:49 Temperature Measurement, Probe Number = 1, T = 19.910000 C 06:45:50 Temperature Measurement, Probe Number = 2, T = 19.884000 C 06:45:51 Temperature Measurement, Probe Number = 3, T = 19.786000 C 06:45:51 Temperature Measurement, Probe Number = 4, T = 19.860000 C 06:45:52 Temperature Measurement, Probe Number = 5, T = 19.872000 C 06:45:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:45:52 Integrated Voltage Measurement... 06:46:14 Voltage Offset Correction: v_off_ini = -0.000000410 V, v_off_fin = -0.000000644 V 06:46:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158420270 Vs 06:46:14 Integrated Voltage Measurement... 06:46:36 Voltage Offset Correction: v_off_ini = 0.000000263 V, v_off_fin = -0.000001676 V 06:46:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158418427 Vs 06:46:50 Temperature Measurement, Probe Number = 0, T = 19.567000 C 06:46:50 Temperature Measurement, Probe Number = 1, T = 19.912000 C 06:46:51 Temperature Measurement, Probe Number = 2, T = 19.885000 C 06:46:52 Temperature Measurement, Probe Number = 3, T = 19.785000 C 06:46:52 Temperature Measurement, Probe Number = 4, T = 19.860000 C 06:46:53 Temperature Measurement, Probe Number = 5, T = 19.872000 C 06:46:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:46:53 Integrated Voltage Measurement... 06:47:15 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000000527 V 06:47:15 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158418487 Vs 06:47:15 Integrated Voltage Measurement... 06:47:37 Voltage Offset Correction: v_off_ini = -0.000000447 V, v_off_fin = -0.000002130 V 06:47:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158396060 Vs 06:47:51 Temperature Measurement, Probe Number = 0, T = 19.564000 C 06:47:51 Temperature Measurement, Probe Number = 1, T = 19.906000 C 06:47:52 Temperature Measurement, Probe Number = 2, T = 19.880000 C 06:47:53 Temperature Measurement, Probe Number = 3, T = 19.783000 C 06:47:53 Temperature Measurement, Probe Number = 4, T = 19.858000 C 06:47:54 Temperature Measurement, Probe Number = 5, T = 19.871000 C 06:47:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.56 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:47:54 Integrated Voltage Measurement... 06:48:16 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000002495 V 06:48:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442697 Vs 06:48:16 Integrated Voltage Measurement... 06:48:39 Voltage Offset Correction: v_off_ini = -0.000001727 V, v_off_fin = -0.000003074 V 06:48:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398348 Vs 06:48:52 Temperature Measurement, Probe Number = 0, T = 19.549000 C 06:48:53 Temperature Measurement, Probe Number = 1, T = 19.906000 C 06:48:53 Temperature Measurement, Probe Number = 2, T = 19.881000 C 06:48:54 Temperature Measurement, Probe Number = 3, T = 19.782000 C 06:48:55 Temperature Measurement, Probe Number = 4, T = 19.859000 C 06:48:55 Temperature Measurement, Probe Number = 5, T = 19.870000 C 06:48:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.55 P2 = Top_US_Module, Value = 19.91 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.86 P6 = Top_Jaw, Value = 19.87 06:48:55 Integrated Voltage Measurement... 06:49:17 Voltage Offset Correction: v_off_ini = -0.000001552 V, v_off_fin = -0.000001808 V 06:49:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158431345 Vs 06:49:18 Integrated Voltage Measurement... 06:49:41 Voltage Offset Correction: v_off_ini = -0.000000329 V, v_off_fin = -0.000003426 V 06:49:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386973 Vs 07:45:55 Temperature Measurement, Probe Number = 0, T = 19.955000 C 07:45:55 Temperature Measurement, Probe Number = 1, T = 19.903000 C 07:45:56 Temperature Measurement, Probe Number = 2, T = 19.878000 C 07:45:57 Temperature Measurement, Probe Number = 3, T = 19.785000 C 07:45:57 Temperature Measurement, Probe Number = 4, T = 19.851000 C 07:45:58 Temperature Measurement, Probe Number = 5, T = 19.862000 C 07:45:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:45:58 Integrated Voltage Measurement... 07:46:20 Voltage Offset Correction: v_off_ini = -0.000000205 V, v_off_fin = -0.000004977 V 07:46:21 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.158491534 Vs 07:46:21 Integrated Voltage Measurement... 07:46:43 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000002898 V 07:46:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434804 Vs 07:46:57 Temperature Measurement, Probe Number = 0, T = 19.899000 C 07:46:57 Temperature Measurement, Probe Number = 1, T = 19.902000 C 07:46:58 Temperature Measurement, Probe Number = 2, T = 19.878000 C 07:46:58 Temperature Measurement, Probe Number = 3, T = 19.786000 C 07:46:59 Temperature Measurement, Probe Number = 4, T = 19.851000 C 07:47:00 Temperature Measurement, Probe Number = 5, T = 19.861000 C 07:47:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:47:00 Integrated Voltage Measurement... 07:47:22 Voltage Offset Correction: v_off_ini = -0.000001829 V, v_off_fin = -0.000000907 V 07:47:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158434392 Vs 07:47:22 Integrated Voltage Measurement... 07:47:44 Voltage Offset Correction: v_off_ini = -0.000000951 V, v_off_fin = -0.000001990 V 07:47:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158413436 Vs 07:47:58 Temperature Measurement, Probe Number = 0, T = 19.869000 C 07:47:59 Temperature Measurement, Probe Number = 1, T = 19.900000 C 07:47:59 Temperature Measurement, Probe Number = 2, T = 19.877000 C 07:48:00 Temperature Measurement, Probe Number = 3, T = 19.786000 C 07:48:00 Temperature Measurement, Probe Number = 4, T = 19.848000 C 07:48:01 Temperature Measurement, Probe Number = 5, T = 19.861000 C 07:48:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:48:01 Integrated Voltage Measurement... 07:48:23 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000002794 V 07:48:24 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158443805 Vs 07:48:24 Integrated Voltage Measurement... 07:48:46 Voltage Offset Correction: v_off_ini = -0.000000278 V, v_off_fin = -0.000003418 V 07:48:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158425905 Vs 07:49:00 Temperature Measurement, Probe Number = 0, T = 19.865000 C 07:49:00 Temperature Measurement, Probe Number = 1, T = 19.899000 C 07:49:01 Temperature Measurement, Probe Number = 2, T = 19.873000 C 07:49:02 Temperature Measurement, Probe Number = 3, T = 19.786000 C 07:49:02 Temperature Measurement, Probe Number = 4, T = 19.848000 C 07:49:03 Temperature Measurement, Probe Number = 5, T = 19.860000 C 07:49:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:49:03 Integrated Voltage Measurement... 07:49:25 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = 0.000000198 V 07:49:25 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158418297 Vs 07:49:25 Integrated Voltage Measurement... 07:49:47 Voltage Offset Correction: v_off_ini = 0.000001932 V, v_off_fin = -0.000002840 V 07:49:48 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443741 Vs 07:50:01 Temperature Measurement, Probe Number = 0, T = 19.855000 C 07:50:02 Temperature Measurement, Probe Number = 1, T = 19.900000 C 07:50:02 Temperature Measurement, Probe Number = 2, T = 19.874000 C 07:50:03 Temperature Measurement, Probe Number = 3, T = 19.786000 C 07:50:04 Temperature Measurement, Probe Number = 4, T = 19.847000 C 07:50:04 Temperature Measurement, Probe Number = 5, T = 19.860000 C 07:50:04 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:50:04 Integrated Voltage Measurement... 07:50:26 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000001851 V 07:50:26 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158451463 Vs 07:50:26 Integrated Voltage Measurement... 07:50:49 Voltage Offset Correction: v_off_ini = -0.000000505 V, v_off_fin = -0.000001580 V 07:50:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407607 Vs 07:51:02 Temperature Measurement, Probe Number = 0, T = 19.859000 C 07:51:03 Temperature Measurement, Probe Number = 1, T = 19.896000 C 07:51:03 Temperature Measurement, Probe Number = 2, T = 19.872000 C 07:51:04 Temperature Measurement, Probe Number = 3, T = 19.785000 C 07:51:05 Temperature Measurement, Probe Number = 4, T = 19.847000 C 07:51:05 Temperature Measurement, Probe Number = 5, T = 19.859000 C 07:51:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:51:05 Integrated Voltage Measurement... 07:51:27 Voltage Offset Correction: v_off_ini = -0.000001339 V, v_off_fin = 0.000000000 V 07:51:27 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158428712 Vs 07:51:27 Integrated Voltage Measurement... 07:51:50 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000005422 V 07:51:50 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158398187 Vs 07:52:03 Temperature Measurement, Probe Number = 0, T = 19.869000 C 07:52:04 Temperature Measurement, Probe Number = 1, T = 19.899000 C 07:52:05 Temperature Measurement, Probe Number = 2, T = 19.873000 C 07:52:05 Temperature Measurement, Probe Number = 3, T = 19.785000 C 07:52:06 Temperature Measurement, Probe Number = 4, T = 19.849000 C 07:52:06 Temperature Measurement, Probe Number = 5, T = 19.861000 C 07:52:06 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:52:06 Integrated Voltage Measurement... 07:52:29 Voltage Offset Correction: v_off_ini = -0.000002488 V, v_off_fin = -0.000001171 V 07:52:29 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158428974 Vs 07:52:29 Integrated Voltage Measurement... 07:52:51 Voltage Offset Correction: v_off_ini = -0.000003161 V, v_off_fin = -0.000002371 V 07:52:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158386430 Vs 07:53:04 Temperature Measurement, Probe Number = 0, T = 19.830000 C 07:53:05 Temperature Measurement, Probe Number = 1, T = 19.900000 C 07:53:06 Temperature Measurement, Probe Number = 2, T = 19.874000 C 07:53:06 Temperature Measurement, Probe Number = 3, T = 19.787000 C 07:53:07 Temperature Measurement, Probe Number = 4, T = 19.849000 C 07:53:07 Temperature Measurement, Probe Number = 5, T = 19.860000 C 07:53:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.83 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:53:07 Integrated Voltage Measurement... 07:53:30 Voltage Offset Correction: v_off_ini = -0.000000900 V, v_off_fin = -0.000004039 V 07:53:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158458631 Vs 07:53:30 Integrated Voltage Measurement... 07:53:52 Voltage Offset Correction: v_off_ini = -0.000002034 V, v_off_fin = -0.000002868 V 07:53:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158397312 Vs 07:54:06 Temperature Measurement, Probe Number = 0, T = 19.865000 C 07:54:06 Temperature Measurement, Probe Number = 1, T = 19.897000 C 07:54:07 Temperature Measurement, Probe Number = 2, T = 19.874000 C 07:54:08 Temperature Measurement, Probe Number = 3, T = 19.789000 C 07:54:08 Temperature Measurement, Probe Number = 4, T = 19.847000 C 07:54:09 Temperature Measurement, Probe Number = 5, T = 19.859000 C 07:54:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.86 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:54:09 Integrated Voltage Measurement... 07:54:31 Voltage Offset Correction: v_off_ini = -0.000000724 V, v_off_fin = -0.000002034 V 07:54:31 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158430039 Vs 07:54:31 Integrated Voltage Measurement... 07:54:53 Voltage Offset Correction: v_off_ini = 0.000000351 V, v_off_fin = -0.000002985 V 07:54:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158403391 Vs 07:55:07 Temperature Measurement, Probe Number = 0, T = 19.869000 C 07:55:08 Temperature Measurement, Probe Number = 1, T = 19.898000 C 07:55:08 Temperature Measurement, Probe Number = 2, T = 19.875000 C 07:55:09 Temperature Measurement, Probe Number = 3, T = 19.785000 C 07:55:09 Temperature Measurement, Probe Number = 4, T = 19.847000 C 07:55:10 Temperature Measurement, Probe Number = 5, T = 19.860000 C 07:55:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.90 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.86 07:55:10 Integrated Voltage Measurement... 07:55:32 Voltage Offset Correction: v_off_ini = -0.000000908 V, v_off_fin = -0.000003191 V 07:55:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158425128 Vs 07:55:33 Integrated Voltage Measurement... 07:55:55 Voltage Offset Correction: v_off_ini = -0.000003527 V, v_off_fin = -0.000002253 V 07:55:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158394297 Vs 08:52:08 Temperature Measurement, Probe Number = 0, T = 19.398000 C 08:52:09 Temperature Measurement, Probe Number = 1, T = 19.847000 C 08:52:10 Temperature Measurement, Probe Number = 2, T = 19.825000 C 08:52:10 Temperature Measurement, Probe Number = 3, T = 19.779000 C 08:52:11 Temperature Measurement, Probe Number = 4, T = 19.820000 C 08:52:11 Temperature Measurement, Probe Number = 5, T = 19.825000 C 08:52:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.40 P2 = Top_US_Module, Value = 19.85 P3 = Bottom_DS_Module, Value = 19.82 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.82 08:52:11 Integrated Voltage Measurement... 08:52:34 Voltage Offset Correction: v_off_ini = -0.000002224 V, v_off_fin = 0.000000007 V 08:52:34 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.158489071 Vs 08:52:34 Integrated Voltage Measurement... 08:52:56 Voltage Offset Correction: v_off_ini = -0.000000263 V, v_off_fin = -0.000003167 V 08:52:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432133 Vs 08:53:10 Temperature Measurement, Probe Number = 0, T = 19.468000 C 08:53:10 Temperature Measurement, Probe Number = 1, T = 19.856000 C 08:53:11 Temperature Measurement, Probe Number = 2, T = 19.842000 C 08:53:12 Temperature Measurement, Probe Number = 3, T = 19.779000 C 08:53:12 Temperature Measurement, Probe Number = 4, T = 19.827000 C 08:53:13 Temperature Measurement, Probe Number = 5, T = 19.828000 C 08:53:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.47 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:53:13 Integrated Voltage Measurement... 08:53:36 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001361 V 08:53:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437653 Vs 08:53:36 Integrated Voltage Measurement... 08:53:58 Voltage Offset Correction: v_off_ini = -0.000000797 V, v_off_fin = -0.000002589 V 08:53:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158421125 Vs 08:54:12 Temperature Measurement, Probe Number = 0, T = 19.523000 C 08:54:13 Temperature Measurement, Probe Number = 1, T = 19.859000 C 08:54:13 Temperature Measurement, Probe Number = 2, T = 19.843000 C 08:54:14 Temperature Measurement, Probe Number = 3, T = 19.779000 C 08:54:15 Temperature Measurement, Probe Number = 4, T = 19.828000 C 08:54:15 Temperature Measurement, Probe Number = 5, T = 19.829000 C 08:54:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.52 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:54:15 Integrated Voltage Measurement... 08:54:37 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000001325 V 08:54:37 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437759 Vs 08:54:37 Integrated Voltage Measurement... 08:55:00 Voltage Offset Correction: v_off_ini = -0.000002319 V, v_off_fin = -0.000002224 V 08:55:00 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158407349 Vs 08:55:14 Temperature Measurement, Probe Number = 0, T = 19.562000 C 08:55:14 Temperature Measurement, Probe Number = 1, T = 19.868000 C 08:55:15 Temperature Measurement, Probe Number = 2, T = 19.856000 C 08:55:15 Temperature Measurement, Probe Number = 3, T = 19.779000 C 08:55:16 Temperature Measurement, Probe Number = 4, T = 19.832000 C 08:55:17 Temperature Measurement, Probe Number = 5, T = 19.831000 C 08:55:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.56 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.78 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:55:17 Integrated Voltage Measurement... 08:55:39 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000000527 V 08:55:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158446718 Vs 08:55:39 Integrated Voltage Measurement... 08:56:02 Voltage Offset Correction: v_off_ini = -0.000002033 V, v_off_fin = -0.000002838 V 08:56:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158407146 Vs 08:56:15 Temperature Measurement, Probe Number = 0, T = 19.604000 C 08:56:16 Temperature Measurement, Probe Number = 1, T = 19.865000 C 08:56:16 Temperature Measurement, Probe Number = 2, T = 19.850000 C 08:56:17 Temperature Measurement, Probe Number = 3, T = 19.774000 C 08:56:18 Temperature Measurement, Probe Number = 4, T = 19.832000 C 08:56:18 Temperature Measurement, Probe Number = 5, T = 19.830000 C 08:56:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.60 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:56:18 Integrated Voltage Measurement... 08:56:40 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000000848 V 08:56:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158442160 Vs 08:56:40 Integrated Voltage Measurement... 08:57:03 Voltage Offset Correction: v_off_ini = -0.000001851 V, v_off_fin = -0.000000088 V 08:57:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158429277 Vs 08:57:16 Temperature Measurement, Probe Number = 0, T = 19.619000 C 08:57:17 Temperature Measurement, Probe Number = 1, T = 19.864000 C 08:57:17 Temperature Measurement, Probe Number = 2, T = 19.848000 C 08:57:18 Temperature Measurement, Probe Number = 3, T = 19.773000 C 08:57:19 Temperature Measurement, Probe Number = 4, T = 19.831000 C 08:57:19 Temperature Measurement, Probe Number = 5, T = 19.829000 C 08:57:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.62 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:57:19 Integrated Voltage Measurement... 08:57:46 Voltage Offset Correction: v_off_ini = -0.000001170 V, v_off_fin = 0.000000300 V 08:57:46 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158449072 Vs 08:57:46 Integrated Voltage Measurement... 08:58:08 Voltage Offset Correction: v_off_ini = -0.000002172 V, v_off_fin = -0.000002582 V 08:58:08 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158399458 Vs 08:58:22 Temperature Measurement, Probe Number = 0, T = 19.573000 C 08:58:22 Temperature Measurement, Probe Number = 1, T = 19.854000 C 08:58:23 Temperature Measurement, Probe Number = 2, T = 19.840000 C 08:58:24 Temperature Measurement, Probe Number = 3, T = 19.769000 C 08:58:24 Temperature Measurement, Probe Number = 4, T = 19.826000 C 08:58:25 Temperature Measurement, Probe Number = 5, T = 19.825000 C 08:58:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.85 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 08:58:25 Integrated Voltage Measurement... 08:58:47 Voltage Offset Correction: v_off_ini = -0.000002019 V, v_off_fin = -0.000000088 V 08:58:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158454034 Vs 08:58:47 Integrated Voltage Measurement... 08:59:09 Voltage Offset Correction: v_off_ini = -0.000001024 V, v_off_fin = -0.000002524 V 08:59:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158420072 Vs 08:59:23 Temperature Measurement, Probe Number = 0, T = 19.556000 C 08:59:23 Temperature Measurement, Probe Number = 1, T = 19.855000 C 08:59:24 Temperature Measurement, Probe Number = 2, T = 19.843000 C 08:59:25 Temperature Measurement, Probe Number = 3, T = 19.769000 C 08:59:25 Temperature Measurement, Probe Number = 4, T = 19.826000 C 08:59:26 Temperature Measurement, Probe Number = 5, T = 19.826000 C 08:59:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.56 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 08:59:26 Integrated Voltage Measurement... 08:59:48 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000000973 V 08:59:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158458410 Vs 08:59:48 Integrated Voltage Measurement... 09:00:10 Voltage Offset Correction: v_off_ini = 0.000001280 V, v_off_fin = -0.000002428 V 09:00:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448723 Vs 09:00:24 Temperature Measurement, Probe Number = 0, T = 19.553000 C 09:00:24 Temperature Measurement, Probe Number = 1, T = 19.856000 C 09:00:25 Temperature Measurement, Probe Number = 2, T = 19.847000 C 09:00:26 Temperature Measurement, Probe Number = 3, T = 19.772000 C 09:00:26 Temperature Measurement, Probe Number = 4, T = 19.825000 C 09:00:27 Temperature Measurement, Probe Number = 5, T = 19.824000 C 09:00:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.55 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.82 09:00:27 Integrated Voltage Measurement... 09:00:49 Voltage Offset Correction: v_off_ini = 0.000000212 V, v_off_fin = -0.000001024 V 09:00:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158437591 Vs 09:00:49 Integrated Voltage Measurement... 09:01:11 Voltage Offset Correction: v_off_ini = 0.000001521 V, v_off_fin = -0.000002487 V 09:01:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432060 Vs 09:01:25 Temperature Measurement, Probe Number = 0, T = 19.565000 C 09:01:25 Temperature Measurement, Probe Number = 1, T = 19.863000 C 09:01:26 Temperature Measurement, Probe Number = 2, T = 19.846000 C 09:01:27 Temperature Measurement, Probe Number = 3, T = 19.772000 C 09:01:27 Temperature Measurement, Probe Number = 4, T = 19.827000 C 09:01:28 Temperature Measurement, Probe Number = 5, T = 19.826000 C 09:01:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.57 P2 = Top_US_Module, Value = 19.86 P3 = Bottom_DS_Module, Value = 19.85 P4 = Encode_Arm, Value = 19.77 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.83 09:01:28 Integrated Voltage Measurement... 09:01:50 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = 0.000002275 V 09:01:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158422739 Vs 09:01:50 Integrated Voltage Measurement... 09:02:12 Voltage Offset Correction: v_off_ini = -0.000002216 V, v_off_fin = -0.000002180 V 09:02:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424472 Vs 09:58:26 Temperature Measurement, Probe Number = 0, T = 19.909000 C 09:58:27 Temperature Measurement, Probe Number = 1, T = 19.868000 C 09:58:27 Temperature Measurement, Probe Number = 2, T = 19.857000 C 09:58:28 Temperature Measurement, Probe Number = 3, T = 19.787000 C 09:58:29 Temperature Measurement, Probe Number = 4, T = 19.828000 C 09:58:29 Temperature Measurement, Probe Number = 5, T = 19.823000 C 09:58:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 09:58:29 Integrated Voltage Measurement... 09:58:52 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = 0.000000263 V 09:58:52 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158487016 Vs 09:58:52 Integrated Voltage Measurement... 09:59:14 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000002642 V 09:59:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158502588 Vs 09:59:28 Temperature Measurement, Probe Number = 0, T = 19.903000 C 09:59:28 Temperature Measurement, Probe Number = 1, T = 19.870000 C 09:59:29 Temperature Measurement, Probe Number = 2, T = 19.859000 C 09:59:30 Temperature Measurement, Probe Number = 3, T = 19.785000 C 09:59:30 Temperature Measurement, Probe Number = 4, T = 19.828000 C 09:59:31 Temperature Measurement, Probe Number = 5, T = 19.823000 C 09:59:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.90 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 09:59:31 Integrated Voltage Measurement... 09:59:53 Voltage Offset Correction: v_off_ini = -0.000000907 V, v_off_fin = -0.000003542 V 09:59:53 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158487805 Vs 09:59:53 Integrated Voltage Measurement... 10:00:15 Voltage Offset Correction: v_off_ini = -0.000000307 V, v_off_fin = -0.000001969 V 10:00:16 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158447638 Vs 10:00:29 Temperature Measurement, Probe Number = 0, T = 19.871000 C 10:00:30 Temperature Measurement, Probe Number = 1, T = 19.867000 C 10:00:30 Temperature Measurement, Probe Number = 2, T = 19.857000 C 10:00:31 Temperature Measurement, Probe Number = 3, T = 19.786000 C 10:00:32 Temperature Measurement, Probe Number = 4, T = 19.828000 C 10:00:32 Temperature Measurement, Probe Number = 5, T = 19.823000 C 10:00:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:00:32 Integrated Voltage Measurement... 10:00:54 Voltage Offset Correction: v_off_ini = 0.000000044 V, v_off_fin = -0.000002342 V 10:00:54 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158452885 Vs 10:00:54 Integrated Voltage Measurement... 10:01:16 Voltage Offset Correction: v_off_ini = -0.000001170 V, v_off_fin = -0.000000688 V 10:01:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158428649 Vs 10:01:30 Temperature Measurement, Probe Number = 0, T = 19.872000 C 10:01:31 Temperature Measurement, Probe Number = 1, T = 19.869000 C 10:01:31 Temperature Measurement, Probe Number = 2, T = 19.860000 C 10:01:32 Temperature Measurement, Probe Number = 3, T = 19.786000 C 10:01:33 Temperature Measurement, Probe Number = 4, T = 19.828000 C 10:01:33 Temperature Measurement, Probe Number = 5, T = 19.823000 C 10:01:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.87 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:01:33 Integrated Voltage Measurement... 10:01:55 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = -0.000001097 V 10:01:55 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158461703 Vs 10:01:55 Integrated Voltage Measurement... 10:02:18 Voltage Offset Correction: v_off_ini = -0.000000622 V, v_off_fin = -0.000002108 V 10:02:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158434336 Vs 10:02:31 Temperature Measurement, Probe Number = 0, T = 19.882000 C 10:02:32 Temperature Measurement, Probe Number = 1, T = 19.869000 C 10:02:32 Temperature Measurement, Probe Number = 2, T = 19.856000 C 10:02:33 Temperature Measurement, Probe Number = 3, T = 19.789000 C 10:02:34 Temperature Measurement, Probe Number = 4, T = 19.826000 C 10:02:34 Temperature Measurement, Probe Number = 5, T = 19.823000 C 10:02:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:02:34 Integrated Voltage Measurement... 10:02:56 Voltage Offset Correction: v_off_ini = -0.000002517 V, v_off_fin = -0.000002115 V 10:02:57 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158496994 Vs 10:02:57 Integrated Voltage Measurement... 10:03:19 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = -0.000003249 V 10:03:19 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158441517 Vs 10:03:33 Temperature Measurement, Probe Number = 0, T = 19.876000 C 10:03:33 Temperature Measurement, Probe Number = 1, T = 19.870000 C 10:03:34 Temperature Measurement, Probe Number = 2, T = 19.860000 C 10:03:35 Temperature Measurement, Probe Number = 3, T = 19.791000 C 10:03:35 Temperature Measurement, Probe Number = 4, T = 19.828000 C 10:03:36 Temperature Measurement, Probe Number = 5, T = 19.823000 C 10:03:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.88 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:03:36 Integrated Voltage Measurement... 10:03:58 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000002934 V 10:03:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158484661 Vs 10:03:58 Integrated Voltage Measurement... 10:04:21 Voltage Offset Correction: v_off_ini = -0.000002765 V, v_off_fin = -0.000002495 V 10:04:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158419057 Vs 10:04:34 Temperature Measurement, Probe Number = 0, T = 19.889000 C 10:04:35 Temperature Measurement, Probe Number = 1, T = 19.872000 C 10:04:35 Temperature Measurement, Probe Number = 2, T = 19.861000 C 10:04:36 Temperature Measurement, Probe Number = 3, T = 19.790000 C 10:04:37 Temperature Measurement, Probe Number = 4, T = 19.829000 C 10:04:37 Temperature Measurement, Probe Number = 5, T = 19.825000 C 10:04:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:04:37 Integrated Voltage Measurement... 10:05:00 Voltage Offset Correction: v_off_ini = -0.000001119 V, v_off_fin = 0.000000607 V 10:05:00 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158445746 Vs 10:05:00 Integrated Voltage Measurement... 10:05:22 Voltage Offset Correction: v_off_ini = -0.000003277 V, v_off_fin = -0.000000234 V 10:05:22 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158433819 Vs 10:05:36 Temperature Measurement, Probe Number = 0, T = 19.886000 C 10:05:36 Temperature Measurement, Probe Number = 1, T = 19.871000 C 10:05:37 Temperature Measurement, Probe Number = 2, T = 19.862000 C 10:05:38 Temperature Measurement, Probe Number = 3, T = 19.790000 C 10:05:38 Temperature Measurement, Probe Number = 4, T = 19.829000 C 10:05:39 Temperature Measurement, Probe Number = 5, T = 19.824000 C 10:05:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.89 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:05:39 Integrated Voltage Measurement... 10:06:01 Voltage Offset Correction: v_off_ini = -0.000001090 V, v_off_fin = -0.000000790 V 10:06:01 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158458593 Vs 10:06:01 Integrated Voltage Measurement... 10:06:23 Voltage Offset Correction: v_off_ini = -0.000001661 V, v_off_fin = -0.000002524 V 10:06:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158452096 Vs 10:06:37 Temperature Measurement, Probe Number = 0, T = 19.845000 C 10:06:37 Temperature Measurement, Probe Number = 1, T = 19.872000 C 10:06:38 Temperature Measurement, Probe Number = 2, T = 19.864000 C 10:06:39 Temperature Measurement, Probe Number = 3, T = 19.788000 C 10:06:39 Temperature Measurement, Probe Number = 4, T = 19.830000 C 10:06:40 Temperature Measurement, Probe Number = 5, T = 19.825000 C 10:06:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.84 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:06:40 Integrated Voltage Measurement... 10:07:02 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = 0.000002312 V 10:07:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158406572 Vs 10:07:02 Integrated Voltage Measurement... 10:07:24 Voltage Offset Correction: v_off_ini = 0.000002297 V, v_off_fin = -0.000003204 V 10:07:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158462197 Vs 10:07:38 Temperature Measurement, Probe Number = 0, T = 19.819000 C 10:07:39 Temperature Measurement, Probe Number = 1, T = 19.874000 C 10:07:39 Temperature Measurement, Probe Number = 2, T = 19.864000 C 10:07:40 Temperature Measurement, Probe Number = 3, T = 19.787000 C 10:07:40 Temperature Measurement, Probe Number = 4, T = 19.830000 C 10:07:41 Temperature Measurement, Probe Number = 5, T = 19.825000 C 10:07:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.82 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.86 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.83 P6 = Top_Jaw, Value = 19.82 10:07:41 Integrated Voltage Measurement... 10:08:03 Voltage Offset Correction: v_off_ini = -0.000002787 V, v_off_fin = 0.000000695 V 10:08:03 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158456714 Vs 10:08:03 Integrated Voltage Measurement... 10:08:26 Voltage Offset Correction: v_off_ini = -0.000000176 V, v_off_fin = -0.000003131 V 10:08:26 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158433082 Vs 11:04:39 Temperature Measurement, Probe Number = 0, T = 20.048000 C 11:04:40 Temperature Measurement, Probe Number = 1, T = 19.877000 C 11:04:40 Temperature Measurement, Probe Number = 2, T = 19.867000 C 11:04:41 Temperature Measurement, Probe Number = 3, T = 19.824000 C 11:04:42 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:04:42 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:04:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:04:42 Integrated Voltage Measurement... 11:05:04 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000001295 V 11:05:05 Integrated Voltage Measurement Delta Gap = 0.0040023 m VT = 0.158551232 Vs 11:05:05 Integrated Voltage Measurement... 11:05:27 Voltage Offset Correction: v_off_ini = -0.000000424 V, v_off_fin = -0.000002326 V 11:05:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449844 Vs 11:05:40 Temperature Measurement, Probe Number = 0, T = 20.027000 C 11:05:41 Temperature Measurement, Probe Number = 1, T = 19.877000 C 11:05:42 Temperature Measurement, Probe Number = 2, T = 19.869000 C 11:05:42 Temperature Measurement, Probe Number = 3, T = 19.824000 C 11:05:43 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:05:43 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:05:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:05:43 Integrated Voltage Measurement... 11:06:06 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000001712 V 11:06:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158481257 Vs 11:06:06 Integrated Voltage Measurement... 11:06:28 Voltage Offset Correction: v_off_ini = -0.000000234 V, v_off_fin = -0.000001792 V 11:06:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158453926 Vs 11:06:42 Temperature Measurement, Probe Number = 0, T = 20.014000 C 11:06:43 Temperature Measurement, Probe Number = 1, T = 19.876000 C 11:06:43 Temperature Measurement, Probe Number = 2, T = 19.867000 C 11:06:44 Temperature Measurement, Probe Number = 3, T = 19.823000 C 11:06:44 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:06:45 Temperature Measurement, Probe Number = 5, T = 19.831000 C 11:06:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:06:45 Integrated Voltage Measurement... 11:07:07 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = 0.000000893 V 11:07:07 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158459312 Vs 11:07:07 Integrated Voltage Measurement... 11:07:29 Voltage Offset Correction: v_off_ini = -0.000000285 V, v_off_fin = -0.000001932 V 11:07:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436437 Vs 11:07:43 Temperature Measurement, Probe Number = 0, T = 19.995000 C 11:07:43 Temperature Measurement, Probe Number = 1, T = 19.878000 C 11:07:44 Temperature Measurement, Probe Number = 2, T = 19.867000 C 11:07:45 Temperature Measurement, Probe Number = 3, T = 19.822000 C 11:07:45 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:07:46 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:07:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:07:46 Integrated Voltage Measurement... 11:08:08 Voltage Offset Correction: v_off_ini = -0.000001236 V, v_off_fin = 0.000001990 V 11:08:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158449430 Vs 11:08:08 Integrated Voltage Measurement... 11:08:31 Voltage Offset Correction: v_off_ini = -0.000002195 V, v_off_fin = -0.000003015 V 11:08:31 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158419988 Vs 11:08:44 Temperature Measurement, Probe Number = 0, T = 19.982000 C 11:08:45 Temperature Measurement, Probe Number = 1, T = 19.878000 C 11:08:45 Temperature Measurement, Probe Number = 2, T = 19.869000 C 11:08:46 Temperature Measurement, Probe Number = 3, T = 19.822000 C 11:08:47 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:08:47 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:08:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:08:47 Integrated Voltage Measurement... 11:09:09 Voltage Offset Correction: v_off_ini = -0.000002327 V, v_off_fin = -0.000001193 V 11:09:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158470608 Vs 11:09:09 Integrated Voltage Measurement... 11:09:32 Voltage Offset Correction: v_off_ini = -0.000004331 V, v_off_fin = -0.000001434 V 11:09:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158411259 Vs 11:09:46 Temperature Measurement, Probe Number = 0, T = 19.973000 C 11:09:46 Temperature Measurement, Probe Number = 1, T = 19.877000 C 11:09:47 Temperature Measurement, Probe Number = 2, T = 19.869000 C 11:09:48 Temperature Measurement, Probe Number = 3, T = 19.821000 C 11:09:48 Temperature Measurement, Probe Number = 4, T = 19.841000 C 11:09:49 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:09:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:09:49 Integrated Voltage Measurement... 11:10:11 Voltage Offset Correction: v_off_ini = -0.000001785 V, v_off_fin = -0.000001258 V 11:10:11 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158462821 Vs 11:10:11 Integrated Voltage Measurement... 11:10:33 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = -0.000002656 V 11:10:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437396 Vs 11:10:47 Temperature Measurement, Probe Number = 0, T = 19.964000 C 11:10:47 Temperature Measurement, Probe Number = 1, T = 19.878000 C 11:10:48 Temperature Measurement, Probe Number = 2, T = 19.868000 C 11:10:49 Temperature Measurement, Probe Number = 3, T = 19.821000 C 11:10:49 Temperature Measurement, Probe Number = 4, T = 19.840000 C 11:10:50 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:10:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:10:50 Integrated Voltage Measurement... 11:11:12 Voltage Offset Correction: v_off_ini = -0.000000695 V, v_off_fin = -0.000001310 V 11:11:12 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158440739 Vs 11:11:12 Integrated Voltage Measurement... 11:11:34 Voltage Offset Correction: v_off_ini = -0.000001185 V, v_off_fin = -0.000002817 V 11:11:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430999 Vs 11:11:48 Temperature Measurement, Probe Number = 0, T = 19.967000 C 11:11:49 Temperature Measurement, Probe Number = 1, T = 19.877000 C 11:11:49 Temperature Measurement, Probe Number = 2, T = 19.868000 C 11:11:50 Temperature Measurement, Probe Number = 3, T = 19.822000 C 11:11:50 Temperature Measurement, Probe Number = 4, T = 19.840000 C 11:11:51 Temperature Measurement, Probe Number = 5, T = 19.832000 C 11:11:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:11:51 Integrated Voltage Measurement... 11:12:13 Voltage Offset Correction: v_off_ini = -0.000001668 V, v_off_fin = -0.000000819 V 11:12:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158447282 Vs 11:12:13 Integrated Voltage Measurement... 11:12:36 Voltage Offset Correction: v_off_ini = -0.000002685 V, v_off_fin = -0.000001836 V 11:12:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158395052 Vs 11:12:50 Temperature Measurement, Probe Number = 0, T = 19.963000 C 11:12:50 Temperature Measurement, Probe Number = 1, T = 19.875000 C 11:12:51 Temperature Measurement, Probe Number = 2, T = 19.868000 C 11:12:52 Temperature Measurement, Probe Number = 3, T = 19.821000 C 11:12:52 Temperature Measurement, Probe Number = 4, T = 19.839000 C 11:12:53 Temperature Measurement, Probe Number = 5, T = 19.832000 C 11:12:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:12:53 Integrated Voltage Measurement... 11:13:15 Voltage Offset Correction: v_off_ini = -0.000003329 V, v_off_fin = 0.000001515 V 11:13:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158447700 Vs 11:13:15 Integrated Voltage Measurement... 11:13:38 Voltage Offset Correction: v_off_ini = -0.000001705 V, v_off_fin = -0.000003541 V 11:13:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423245 Vs 11:13:51 Temperature Measurement, Probe Number = 0, T = 19.932000 C 11:13:52 Temperature Measurement, Probe Number = 1, T = 19.874000 C 11:13:52 Temperature Measurement, Probe Number = 2, T = 19.869000 C 11:13:53 Temperature Measurement, Probe Number = 3, T = 19.819000 C 11:13:54 Temperature Measurement, Probe Number = 4, T = 19.839000 C 11:13:54 Temperature Measurement, Probe Number = 5, T = 19.833000 C 11:13:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.93 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.82 P5 = Bottom_Jaw, Value = 19.84 P6 = Top_Jaw, Value = 19.83 11:13:54 Integrated Voltage Measurement... 11:14:20 Voltage Offset Correction: v_off_ini = -0.000001748 V, v_off_fin = 0.000000000 V 11:14:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158456587 Vs 11:14:21 Integrated Voltage Measurement... 11:14:43 Voltage Offset Correction: v_off_ini = -0.000001646 V, v_off_fin = -0.000001156 V 11:14:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158428250 Vs 12:10:56 Temperature Measurement, Probe Number = 0, T = 19.706000 C 12:10:57 Temperature Measurement, Probe Number = 1, T = 19.830000 C 12:10:58 Temperature Measurement, Probe Number = 2, T = 19.833000 C 12:10:58 Temperature Measurement, Probe Number = 3, T = 19.796000 C 12:10:59 Temperature Measurement, Probe Number = 4, T = 19.819000 C 12:10:59 Temperature Measurement, Probe Number = 5, T = 19.799000 C 12:10:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.71 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:10:59 Integrated Voltage Measurement... 12:11:22 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000000790 V 12:11:22 Integrated Voltage Measurement Delta Gap = 0.0040006 m VT = 0.158471583 Vs 12:11:22 Integrated Voltage Measurement... 12:11:50 Voltage Offset Correction: v_off_ini = -0.000000563 V, v_off_fin = -0.000001148 V 12:11:50 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158451717 Vs 12:12:04 Temperature Measurement, Probe Number = 0, T = 19.682000 C 12:12:04 Temperature Measurement, Probe Number = 1, T = 19.830000 C 12:12:05 Temperature Measurement, Probe Number = 2, T = 19.836000 C 12:12:06 Temperature Measurement, Probe Number = 3, T = 19.795000 C 12:12:06 Temperature Measurement, Probe Number = 4, T = 19.820000 C 12:12:07 Temperature Measurement, Probe Number = 5, T = 19.798000 C 12:12:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.80 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:12:07 Integrated Voltage Measurement... 12:12:29 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = 0.000002685 V 12:12:29 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158438135 Vs 12:12:29 Integrated Voltage Measurement... 12:12:51 Voltage Offset Correction: v_off_ini = -0.000001302 V, v_off_fin = -0.000001470 V 12:12:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158458945 Vs 12:13:05 Temperature Measurement, Probe Number = 0, T = 19.680000 C 12:13:05 Temperature Measurement, Probe Number = 1, T = 19.833000 C 12:13:06 Temperature Measurement, Probe Number = 2, T = 19.843000 C 12:13:07 Temperature Measurement, Probe Number = 3, T = 19.792000 C 12:13:07 Temperature Measurement, Probe Number = 4, T = 19.820000 C 12:13:08 Temperature Measurement, Probe Number = 5, T = 19.798000 C 12:13:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:13:08 Integrated Voltage Measurement... 12:13:30 Voltage Offset Correction: v_off_ini = -0.000003372 V, v_off_fin = -0.000000234 V 12:13:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158479939 Vs 12:13:30 Integrated Voltage Measurement... 12:13:52 Voltage Offset Correction: v_off_ini = -0.000000241 V, v_off_fin = -0.000003241 V 12:13:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451541 Vs 12:14:06 Temperature Measurement, Probe Number = 0, T = 19.670000 C 12:14:06 Temperature Measurement, Probe Number = 1, T = 19.829000 C 12:14:07 Temperature Measurement, Probe Number = 2, T = 19.842000 C 12:14:08 Temperature Measurement, Probe Number = 3, T = 19.792000 C 12:14:08 Temperature Measurement, Probe Number = 4, T = 19.818000 C 12:14:09 Temperature Measurement, Probe Number = 5, T = 19.799000 C 12:14:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.67 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:14:09 Integrated Voltage Measurement... 12:14:31 Voltage Offset Correction: v_off_ini = -0.000002772 V, v_off_fin = -0.000001939 V 12:14:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158479477 Vs 12:14:31 Integrated Voltage Measurement... 12:14:53 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000003401 V 12:14:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158452767 Vs 12:15:07 Temperature Measurement, Probe Number = 0, T = 19.675000 C 12:15:08 Temperature Measurement, Probe Number = 1, T = 19.828000 C 12:15:08 Temperature Measurement, Probe Number = 2, T = 19.843000 C 12:15:09 Temperature Measurement, Probe Number = 3, T = 19.791000 C 12:15:09 Temperature Measurement, Probe Number = 4, T = 19.817000 C 12:15:10 Temperature Measurement, Probe Number = 5, T = 19.796000 C 12:15:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.68 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:15:10 Integrated Voltage Measurement... 12:15:32 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000000029 V 12:15:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158478805 Vs 12:15:32 Integrated Voltage Measurement... 12:15:54 Voltage Offset Correction: v_off_ini = -0.000000702 V, v_off_fin = -0.000002567 V 12:15:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158475461 Vs 12:16:08 Temperature Measurement, Probe Number = 0, T = 19.652000 C 12:16:09 Temperature Measurement, Probe Number = 1, T = 19.830000 C 12:16:09 Temperature Measurement, Probe Number = 2, T = 19.838000 C 12:16:10 Temperature Measurement, Probe Number = 3, T = 19.790000 C 12:16:10 Temperature Measurement, Probe Number = 4, T = 19.818000 C 12:16:11 Temperature Measurement, Probe Number = 5, T = 19.795000 C 12:16:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.65 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:16:11 Integrated Voltage Measurement... 12:16:33 Voltage Offset Correction: v_off_ini = -0.000003431 V, v_off_fin = -0.000001778 V 12:16:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158514335 Vs 12:16:33 Integrated Voltage Measurement... 12:16:55 Voltage Offset Correction: v_off_ini = -0.000001902 V, v_off_fin = -0.000001814 V 12:16:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158445772 Vs 12:17:09 Temperature Measurement, Probe Number = 0, T = 19.655000 C 12:17:10 Temperature Measurement, Probe Number = 1, T = 19.823000 C 12:17:10 Temperature Measurement, Probe Number = 2, T = 19.839000 C 12:17:11 Temperature Measurement, Probe Number = 3, T = 19.793000 C 12:17:11 Temperature Measurement, Probe Number = 4, T = 19.817000 C 12:17:12 Temperature Measurement, Probe Number = 5, T = 19.796000 C 12:17:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.66 P2 = Top_US_Module, Value = 19.82 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:17:12 Integrated Voltage Measurement... 12:17:34 Voltage Offset Correction: v_off_ini = -0.000002502 V, v_off_fin = -0.000000819 V 12:17:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158486322 Vs 12:17:34 Integrated Voltage Measurement... 12:17:56 Voltage Offset Correction: v_off_ini = -0.000000673 V, v_off_fin = -0.000001404 V 12:17:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158464771 Vs 12:18:10 Temperature Measurement, Probe Number = 0, T = 19.644000 C 12:18:11 Temperature Measurement, Probe Number = 1, T = 19.831000 C 12:18:11 Temperature Measurement, Probe Number = 2, T = 19.842000 C 12:18:12 Temperature Measurement, Probe Number = 3, T = 19.792000 C 12:18:12 Temperature Measurement, Probe Number = 4, T = 19.817000 C 12:18:13 Temperature Measurement, Probe Number = 5, T = 19.795000 C 12:18:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.64 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:18:13 Integrated Voltage Measurement... 12:18:35 Voltage Offset Correction: v_off_ini = -0.000001931 V, v_off_fin = -0.000001163 V 12:18:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158478995 Vs 12:18:35 Integrated Voltage Measurement... 12:18:57 Voltage Offset Correction: v_off_ini = -0.000001748 V, v_off_fin = -0.000001938 V 12:18:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449730 Vs 12:19:11 Temperature Measurement, Probe Number = 0, T = 19.691000 C 12:19:12 Temperature Measurement, Probe Number = 1, T = 19.834000 C 12:19:12 Temperature Measurement, Probe Number = 2, T = 19.843000 C 12:19:13 Temperature Measurement, Probe Number = 3, T = 19.794000 C 12:19:13 Temperature Measurement, Probe Number = 4, T = 19.819000 C 12:19:14 Temperature Measurement, Probe Number = 5, T = 19.796000 C 12:19:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.69 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.84 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:19:14 Integrated Voltage Measurement... 12:19:36 Voltage Offset Correction: v_off_ini = 0.000000410 V, v_off_fin = 0.000000029 V 12:19:36 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459872 Vs 12:19:36 Integrated Voltage Measurement... 12:19:59 Voltage Offset Correction: v_off_ini = -0.000003569 V, v_off_fin = -0.000002040 V 12:19:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444637 Vs 12:20:13 Temperature Measurement, Probe Number = 0, T = 19.656000 C 12:20:13 Temperature Measurement, Probe Number = 1, T = 19.828000 C 12:20:14 Temperature Measurement, Probe Number = 2, T = 19.834000 C 12:20:14 Temperature Measurement, Probe Number = 3, T = 19.792000 C 12:20:15 Temperature Measurement, Probe Number = 4, T = 19.815000 C 12:20:16 Temperature Measurement, Probe Number = 5, T = 19.795000 C 12:20:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.66 P2 = Top_US_Module, Value = 19.83 P3 = Bottom_DS_Module, Value = 19.83 P4 = Encode_Arm, Value = 19.79 P5 = Bottom_Jaw, Value = 19.82 P6 = Top_Jaw, Value = 19.80 12:20:16 Integrated Voltage Measurement... 12:20:38 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000000593 V 12:20:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158465610 Vs 12:20:38 Integrated Voltage Measurement... 12:21:00 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000001361 V 12:21:00 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158464682 Vs 13:17:14 Temperature Measurement, Probe Number = 0, T = 20.094000 C 13:17:14 Temperature Measurement, Probe Number = 1, T = 19.867000 C 13:17:15 Temperature Measurement, Probe Number = 2, T = 19.873000 C 13:17:15 Temperature Measurement, Probe Number = 3, T = 19.847000 C 13:17:16 Temperature Measurement, Probe Number = 4, T = 19.849000 C 13:17:17 Temperature Measurement, Probe Number = 5, T = 19.825000 C 13:17:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.82 13:17:17 Integrated Voltage Measurement... 13:17:39 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000000797 V 13:17:39 Integrated Voltage Measurement Delta Gap = 0.0040022 m VT = 0.158566728 Vs 13:17:39 Integrated Voltage Measurement... 13:18:01 Voltage Offset Correction: v_off_ini = -0.000000849 V, v_off_fin = -0.000001302 V 13:18:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158478644 Vs 13:18:15 Temperature Measurement, Probe Number = 0, T = 20.140000 C 13:18:16 Temperature Measurement, Probe Number = 1, T = 19.867000 C 13:18:16 Temperature Measurement, Probe Number = 2, T = 19.873000 C 13:18:17 Temperature Measurement, Probe Number = 3, T = 19.850000 C 13:18:17 Temperature Measurement, Probe Number = 4, T = 19.849000 C 13:18:18 Temperature Measurement, Probe Number = 5, T = 19.825000 C 13:18:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.87 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.82 13:18:18 Integrated Voltage Measurement... 13:18:40 Voltage Offset Correction: v_off_ini = -0.000003256 V, v_off_fin = -0.000003080 V 13:18:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158522677 Vs 13:18:40 Integrated Voltage Measurement... 13:19:02 Voltage Offset Correction: v_off_ini = -0.000002458 V, v_off_fin = -0.000002546 V 13:19:03 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158444825 Vs 13:19:16 Temperature Measurement, Probe Number = 0, T = 20.181000 C 13:19:17 Temperature Measurement, Probe Number = 1, T = 19.874000 C 13:19:17 Temperature Measurement, Probe Number = 2, T = 19.879000 C 13:19:18 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:19:19 Temperature Measurement, Probe Number = 4, T = 19.852000 C 13:19:19 Temperature Measurement, Probe Number = 5, T = 19.828000 C 13:19:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:19:19 Integrated Voltage Measurement... 13:19:41 Voltage Offset Correction: v_off_ini = 0.000001010 V, v_off_fin = -0.000000922 V 13:19:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158452737 Vs 13:19:42 Integrated Voltage Measurement... 13:20:04 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000002217 V 13:20:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158449277 Vs 13:20:18 Temperature Measurement, Probe Number = 0, T = 20.197000 C 13:20:18 Temperature Measurement, Probe Number = 1, T = 19.875000 C 13:20:19 Temperature Measurement, Probe Number = 2, T = 19.881000 C 13:20:20 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:20:20 Temperature Measurement, Probe Number = 4, T = 19.853000 C 13:20:21 Temperature Measurement, Probe Number = 5, T = 19.829000 C 13:20:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:20:21 Integrated Voltage Measurement... 13:20:43 Voltage Offset Correction: v_off_ini = -0.000001808 V, v_off_fin = -0.000001574 V 13:20:43 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158483658 Vs 13:20:43 Integrated Voltage Measurement... 13:21:05 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001961 V 13:21:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158455560 Vs 13:21:19 Temperature Measurement, Probe Number = 0, T = 20.182000 C 13:21:19 Temperature Measurement, Probe Number = 1, T = 19.872000 C 13:21:20 Temperature Measurement, Probe Number = 2, T = 19.880000 C 13:21:21 Temperature Measurement, Probe Number = 3, T = 19.854000 C 13:21:21 Temperature Measurement, Probe Number = 4, T = 19.853000 C 13:21:22 Temperature Measurement, Probe Number = 5, T = 19.827000 C 13:21:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.85 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:21:22 Integrated Voltage Measurement... 13:21:44 Voltage Offset Correction: v_off_ini = -0.000000959 V, v_off_fin = -0.000001742 V 13:21:44 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158468610 Vs 13:21:44 Integrated Voltage Measurement... 13:22:06 Voltage Offset Correction: v_off_ini = -0.000001990 V, v_off_fin = -0.000002583 V 13:22:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447572 Vs 13:22:20 Temperature Measurement, Probe Number = 0, T = 20.162000 C 13:22:21 Temperature Measurement, Probe Number = 1, T = 19.871000 C 13:22:21 Temperature Measurement, Probe Number = 2, T = 19.878000 C 13:22:22 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:22:23 Temperature Measurement, Probe Number = 4, T = 19.852000 C 13:22:23 Temperature Measurement, Probe Number = 5, T = 19.827000 C 13:22:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:22:23 Integrated Voltage Measurement... 13:22:45 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000000424 V 13:22:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158488920 Vs 13:22:45 Integrated Voltage Measurement... 13:23:07 Voltage Offset Correction: v_off_ini = -0.000000249 V, v_off_fin = -0.000002509 V 13:23:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158453783 Vs 13:23:21 Temperature Measurement, Probe Number = 0, T = 20.126000 C 13:23:22 Temperature Measurement, Probe Number = 1, T = 19.870000 C 13:23:22 Temperature Measurement, Probe Number = 2, T = 19.878000 C 13:23:23 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:23:24 Temperature Measurement, Probe Number = 4, T = 19.851000 C 13:23:24 Temperature Measurement, Probe Number = 5, T = 19.827000 C 13:23:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:23:24 Integrated Voltage Measurement... 13:23:48 Voltage Offset Correction: v_off_ini = -0.000001097 V, v_off_fin = -0.000002224 V 13:23:48 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158485242 Vs 13:23:48 Integrated Voltage Measurement... 13:24:10 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000002312 V 13:24:10 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158449992 Vs 13:24:24 Temperature Measurement, Probe Number = 0, T = 20.150000 C 13:24:24 Temperature Measurement, Probe Number = 1, T = 19.871000 C 13:24:25 Temperature Measurement, Probe Number = 2, T = 19.878000 C 13:24:26 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:24:26 Temperature Measurement, Probe Number = 4, T = 19.852000 C 13:24:27 Temperature Measurement, Probe Number = 5, T = 19.827000 C 13:24:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:24:27 Integrated Voltage Measurement... 13:24:49 Voltage Offset Correction: v_off_ini = -0.000000827 V, v_off_fin = -0.000003790 V 13:24:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158506368 Vs 13:24:49 Integrated Voltage Measurement... 13:25:11 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = -0.000002429 V 13:25:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451425 Vs 13:25:25 Temperature Measurement, Probe Number = 0, T = 20.161000 C 13:25:26 Temperature Measurement, Probe Number = 1, T = 19.873000 C 13:25:26 Temperature Measurement, Probe Number = 2, T = 19.881000 C 13:25:27 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:25:27 Temperature Measurement, Probe Number = 4, T = 19.853000 C 13:25:28 Temperature Measurement, Probe Number = 5, T = 19.828000 C 13:25:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:25:28 Integrated Voltage Measurement... 13:25:50 Voltage Offset Correction: v_off_ini = -0.000002276 V, v_off_fin = -0.000002839 V 13:25:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158509469 Vs 13:25:50 Integrated Voltage Measurement... 13:26:12 Voltage Offset Correction: v_off_ini = -0.000000512 V, v_off_fin = -0.000001324 V 13:26:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158465412 Vs 13:26:26 Temperature Measurement, Probe Number = 0, T = 20.189000 C 13:26:27 Temperature Measurement, Probe Number = 1, T = 19.874000 C 13:26:27 Temperature Measurement, Probe Number = 2, T = 19.880000 C 13:26:28 Temperature Measurement, Probe Number = 3, T = 19.855000 C 13:26:28 Temperature Measurement, Probe Number = 4, T = 19.854000 C 13:26:29 Temperature Measurement, Probe Number = 5, T = 19.829000 C 13:26:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 19.87 P3 = Bottom_DS_Module, Value = 19.88 P4 = Encode_Arm, Value = 19.86 P5 = Bottom_Jaw, Value = 19.85 P6 = Top_Jaw, Value = 19.83 13:26:29 Integrated Voltage Measurement... 13:26:51 Voltage Offset Correction: v_off_ini = -0.000002202 V, v_off_fin = 0.000000922 V 13:26:51 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158476661 Vs 13:26:51 Integrated Voltage Measurement... 13:27:13 Voltage Offset Correction: v_off_ini = 0.000000702 V, v_off_fin = -0.000001346 V 13:27:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158470116 Vs 14:23:27 Temperature Measurement, Probe Number = 0, T = 20.019000 C 14:23:28 Temperature Measurement, Probe Number = 1, T = 19.889000 C 14:23:28 Temperature Measurement, Probe Number = 2, T = 19.899000 C 14:23:29 Temperature Measurement, Probe Number = 3, T = 19.891000 C 14:23:30 Temperature Measurement, Probe Number = 4, T = 19.877000 C 14:23:30 Temperature Measurement, Probe Number = 5, T = 19.851000 C 14:23:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:23:30 Integrated Voltage Measurement... 14:23:52 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000001163 V 14:23:53 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.158546696 Vs 14:23:53 Integrated Voltage Measurement... 14:24:15 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = -0.000002350 V 14:24:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158457708 Vs 14:24:29 Temperature Measurement, Probe Number = 0, T = 19.994000 C 14:24:29 Temperature Measurement, Probe Number = 1, T = 19.888000 C 14:24:30 Temperature Measurement, Probe Number = 2, T = 19.900000 C 14:24:31 Temperature Measurement, Probe Number = 3, T = 19.891000 C 14:24:31 Temperature Measurement, Probe Number = 4, T = 19.877000 C 14:24:32 Temperature Measurement, Probe Number = 5, T = 19.851000 C 14:24:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.99 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:24:32 Integrated Voltage Measurement... 14:24:54 Voltage Offset Correction: v_off_ini = -0.000000878 V, v_off_fin = -0.000002700 V 14:24:54 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158499658 Vs 14:24:54 Integrated Voltage Measurement... 14:25:17 Voltage Offset Correction: v_off_ini = 0.000003366 V, v_off_fin = -0.000002737 V 14:25:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158507752 Vs 14:25:30 Temperature Measurement, Probe Number = 0, T = 19.959000 C 14:25:31 Temperature Measurement, Probe Number = 1, T = 19.888000 C 14:25:31 Temperature Measurement, Probe Number = 2, T = 19.901000 C 14:25:32 Temperature Measurement, Probe Number = 3, T = 19.890000 C 14:25:33 Temperature Measurement, Probe Number = 4, T = 19.875000 C 14:25:33 Temperature Measurement, Probe Number = 5, T = 19.851000 C 14:25:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:25:33 Integrated Voltage Measurement... 14:25:55 Voltage Offset Correction: v_off_ini = -0.000000329 V, v_off_fin = -0.000001405 V 14:25:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158475379 Vs 14:25:55 Integrated Voltage Measurement... 14:26:18 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000003600 V 14:26:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441566 Vs 14:26:32 Temperature Measurement, Probe Number = 0, T = 19.955000 C 14:26:32 Temperature Measurement, Probe Number = 1, T = 19.884000 C 14:26:33 Temperature Measurement, Probe Number = 2, T = 19.903000 C 14:26:34 Temperature Measurement, Probe Number = 3, T = 19.891000 C 14:26:34 Temperature Measurement, Probe Number = 4, T = 19.875000 C 14:26:35 Temperature Measurement, Probe Number = 5, T = 19.848000 C 14:26:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:26:35 Integrated Voltage Measurement... 14:26:57 Voltage Offset Correction: v_off_ini = -0.000000922 V, v_off_fin = -0.000000761 V 14:26:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158478351 Vs 14:26:57 Integrated Voltage Measurement... 14:27:19 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = -0.000002173 V 14:27:19 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158447552 Vs 14:27:33 Temperature Measurement, Probe Number = 0, T = 19.978000 C 14:27:34 Temperature Measurement, Probe Number = 1, T = 19.886000 C 14:27:34 Temperature Measurement, Probe Number = 2, T = 19.902000 C 14:27:35 Temperature Measurement, Probe Number = 3, T = 19.891000 C 14:27:35 Temperature Measurement, Probe Number = 4, T = 19.875000 C 14:27:36 Temperature Measurement, Probe Number = 5, T = 19.850000 C 14:27:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.98 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:27:36 Integrated Voltage Measurement... 14:27:58 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000005613 V 14:27:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158506206 Vs 14:27:59 Integrated Voltage Measurement... 14:28:21 Voltage Offset Correction: v_off_ini = -0.000002839 V, v_off_fin = -0.000003922 V 14:28:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426516 Vs 14:28:35 Temperature Measurement, Probe Number = 0, T = 20.049000 C 14:28:36 Temperature Measurement, Probe Number = 1, T = 19.889000 C 14:28:36 Temperature Measurement, Probe Number = 2, T = 19.903000 C 14:28:37 Temperature Measurement, Probe Number = 3, T = 19.890000 C 14:28:38 Temperature Measurement, Probe Number = 4, T = 19.877000 C 14:28:38 Temperature Measurement, Probe Number = 5, T = 19.848000 C 14:28:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:28:38 Integrated Voltage Measurement... 14:29:00 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000001412 V 14:29:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158485117 Vs 14:29:00 Integrated Voltage Measurement... 14:29:23 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000002993 V 14:29:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440863 Vs 14:29:36 Temperature Measurement, Probe Number = 0, T = 20.027000 C 14:29:37 Temperature Measurement, Probe Number = 1, T = 19.889000 C 14:29:37 Temperature Measurement, Probe Number = 2, T = 19.904000 C 14:29:38 Temperature Measurement, Probe Number = 3, T = 19.888000 C 14:29:39 Temperature Measurement, Probe Number = 4, T = 19.877000 C 14:29:39 Temperature Measurement, Probe Number = 5, T = 19.849000 C 14:29:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:29:39 Integrated Voltage Measurement... 14:30:03 Voltage Offset Correction: v_off_ini = -0.000001874 V, v_off_fin = -0.000002613 V 14:30:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158502403 Vs 14:30:03 Integrated Voltage Measurement... 14:30:25 Voltage Offset Correction: v_off_ini = -0.000000944 V, v_off_fin = -0.000001471 V 14:30:25 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158463422 Vs 14:30:39 Temperature Measurement, Probe Number = 0, T = 19.997000 C 14:30:40 Temperature Measurement, Probe Number = 1, T = 19.881000 C 14:30:40 Temperature Measurement, Probe Number = 2, T = 19.897000 C 14:30:41 Temperature Measurement, Probe Number = 3, T = 19.890000 C 14:30:41 Temperature Measurement, Probe Number = 4, T = 19.876000 C 14:30:42 Temperature Measurement, Probe Number = 5, T = 19.848000 C 14:30:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.88 P6 = Top_Jaw, Value = 19.85 14:30:42 Integrated Voltage Measurement... 14:31:04 Voltage Offset Correction: v_off_ini = -0.000000688 V, v_off_fin = -0.000001610 V 14:31:04 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158484020 Vs 14:31:04 Integrated Voltage Measurement... 14:31:26 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000002459 V 14:31:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158455568 Vs 14:31:40 Temperature Measurement, Probe Number = 0, T = 19.956000 C 14:31:41 Temperature Measurement, Probe Number = 1, T = 19.885000 C 14:31:41 Temperature Measurement, Probe Number = 2, T = 19.895000 C 14:31:42 Temperature Measurement, Probe Number = 3, T = 19.892000 C 14:31:42 Temperature Measurement, Probe Number = 4, T = 19.874000 C 14:31:43 Temperature Measurement, Probe Number = 5, T = 19.847000 C 14:31:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.89 P3 = Bottom_DS_Module, Value = 19.89 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.85 14:31:43 Integrated Voltage Measurement... 14:32:05 Voltage Offset Correction: v_off_ini = -0.000001771 V, v_off_fin = 0.000001244 V 14:32:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158466434 Vs 14:32:05 Integrated Voltage Measurement... 14:32:27 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000003228 V 14:32:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158445603 Vs 14:32:41 Temperature Measurement, Probe Number = 0, T = 19.908000 C 14:32:42 Temperature Measurement, Probe Number = 1, T = 19.881000 C 14:32:42 Temperature Measurement, Probe Number = 2, T = 19.899000 C 14:32:43 Temperature Measurement, Probe Number = 3, T = 19.891000 C 14:32:43 Temperature Measurement, Probe Number = 4, T = 19.872000 C 14:32:44 Temperature Measurement, Probe Number = 5, T = 19.847000 C 14:32:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.91 P2 = Top_US_Module, Value = 19.88 P3 = Bottom_DS_Module, Value = 19.90 P4 = Encode_Arm, Value = 19.89 P5 = Bottom_Jaw, Value = 19.87 P6 = Top_Jaw, Value = 19.85 14:32:44 Integrated Voltage Measurement... 14:33:06 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = 0.000003338 V 14:33:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158430515 Vs 14:33:06 Integrated Voltage Measurement... 14:33:29 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000005240 V 14:33:29 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443701 Vs 15:29:42 Temperature Measurement, Probe Number = 0, T = 20.243000 C 15:29:43 Temperature Measurement, Probe Number = 1, T = 19.920000 C 15:29:43 Temperature Measurement, Probe Number = 2, T = 19.938000 C 15:29:44 Temperature Measurement, Probe Number = 3, T = 19.940000 C 15:29:45 Temperature Measurement, Probe Number = 4, T = 19.911000 C 15:29:45 Temperature Measurement, Probe Number = 5, T = 19.877000 C 15:29:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.24 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.88 15:29:45 Integrated Voltage Measurement... 15:30:07 Voltage Offset Correction: v_off_ini = -0.000001289 V, v_off_fin = -0.000001018 V 15:30:08 Integrated Voltage Measurement Delta Gap = 0.0040016 m VT = 0.158550912 Vs 15:30:08 Integrated Voltage Measurement... 15:30:30 Voltage Offset Correction: v_off_ini = -0.000002079 V, v_off_fin = -0.000004304 V 15:30:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158430439 Vs 15:30:44 Temperature Measurement, Probe Number = 0, T = 20.268000 C 15:30:44 Temperature Measurement, Probe Number = 1, T = 19.923000 C 15:30:45 Temperature Measurement, Probe Number = 2, T = 19.941000 C 15:30:45 Temperature Measurement, Probe Number = 3, T = 19.941000 C 15:30:46 Temperature Measurement, Probe Number = 4, T = 19.915000 C 15:30:47 Temperature Measurement, Probe Number = 5, T = 19.879000 C 15:30:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.92 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.91 P6 = Top_Jaw, Value = 19.88 15:30:47 Integrated Voltage Measurement... 15:31:09 Voltage Offset Correction: v_off_ini = -0.000002510 V, v_off_fin = -0.000000410 V 15:31:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158483009 Vs 15:31:09 Integrated Voltage Measurement... 15:31:32 Voltage Offset Correction: v_off_ini = -0.000000637 V, v_off_fin = -0.000002342 V 15:31:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158469851 Vs 15:31:45 Temperature Measurement, Probe Number = 0, T = 20.253000 C 15:31:46 Temperature Measurement, Probe Number = 1, T = 19.925000 C 15:31:47 Temperature Measurement, Probe Number = 2, T = 19.942000 C 15:31:47 Temperature Measurement, Probe Number = 3, T = 19.938000 C 15:31:48 Temperature Measurement, Probe Number = 4, T = 19.916000 C 15:31:48 Temperature Measurement, Probe Number = 5, T = 19.879000 C 15:31:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:31:49 Integrated Voltage Measurement... 15:32:11 Voltage Offset Correction: v_off_ini = -0.000000981 V, v_off_fin = -0.000000439 V 15:32:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158481137 Vs 15:32:11 Integrated Voltage Measurement... 15:32:33 Voltage Offset Correction: v_off_ini = 0.000007435 V, v_off_fin = -0.000002613 V 15:32:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158538125 Vs 15:32:47 Temperature Measurement, Probe Number = 0, T = 20.231000 C 15:32:47 Temperature Measurement, Probe Number = 1, T = 19.926000 C 15:32:48 Temperature Measurement, Probe Number = 2, T = 19.945000 C 15:32:49 Temperature Measurement, Probe Number = 3, T = 19.941000 C 15:32:49 Temperature Measurement, Probe Number = 4, T = 19.916000 C 15:32:50 Temperature Measurement, Probe Number = 5, T = 19.880000 C 15:32:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:32:50 Integrated Voltage Measurement... 15:33:12 Voltage Offset Correction: v_off_ini = -0.000002050 V, v_off_fin = -0.000001215 V 15:33:12 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158480111 Vs 15:33:12 Integrated Voltage Measurement... 15:33:34 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = -0.000001940 V 15:33:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158460378 Vs 15:33:48 Temperature Measurement, Probe Number = 0, T = 20.248000 C 15:33:49 Temperature Measurement, Probe Number = 1, T = 19.925000 C 15:33:49 Temperature Measurement, Probe Number = 2, T = 19.944000 C 15:33:50 Temperature Measurement, Probe Number = 3, T = 19.944000 C 15:33:50 Temperature Measurement, Probe Number = 4, T = 19.917000 C 15:33:51 Temperature Measurement, Probe Number = 5, T = 19.880000 C 15:33:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:33:51 Integrated Voltage Measurement... 15:34:13 Voltage Offset Correction: v_off_ini = -0.000001823 V, v_off_fin = 0.000001025 V 15:34:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158471694 Vs 15:34:13 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = 0.000000732 V, v_off_fin = -0.000003375 V 15:34:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158445311 Vs 15:34:49 Temperature Measurement, Probe Number = 0, T = 20.222000 C 15:34:50 Temperature Measurement, Probe Number = 1, T = 19.926000 C 15:34:50 Temperature Measurement, Probe Number = 2, T = 19.944000 C 15:34:51 Temperature Measurement, Probe Number = 3, T = 19.943000 C 15:34:52 Temperature Measurement, Probe Number = 4, T = 19.918000 C 15:34:52 Temperature Measurement, Probe Number = 5, T = 19.882000 C 15:34:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.22 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.94 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:34:52 Integrated Voltage Measurement... 15:35:14 Voltage Offset Correction: v_off_ini = -0.000002049 V, v_off_fin = -0.000004018 V 15:35:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158501177 Vs 15:35:14 Integrated Voltage Measurement... 15:35:37 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000002408 V 15:35:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158450616 Vs 15:35:50 Temperature Measurement, Probe Number = 0, T = 20.233000 C 15:35:51 Temperature Measurement, Probe Number = 1, T = 19.927000 C 15:35:51 Temperature Measurement, Probe Number = 2, T = 19.945000 C 15:35:52 Temperature Measurement, Probe Number = 3, T = 19.945000 C 15:35:53 Temperature Measurement, Probe Number = 4, T = 19.918000 C 15:35:53 Temperature Measurement, Probe Number = 5, T = 19.882000 C 15:35:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:35:53 Integrated Voltage Measurement... 15:36:15 Voltage Offset Correction: v_off_ini = -0.000002079 V, v_off_fin = -0.000003660 V 15:36:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158521880 Vs 15:36:16 Integrated Voltage Measurement... 15:36:38 Voltage Offset Correction: v_off_ini = -0.000003631 V, v_off_fin = -0.000000842 V 15:36:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442555 Vs 15:36:51 Temperature Measurement, Probe Number = 0, T = 20.272000 C 15:36:52 Temperature Measurement, Probe Number = 1, T = 19.930000 C 15:36:53 Temperature Measurement, Probe Number = 2, T = 19.949000 C 15:36:53 Temperature Measurement, Probe Number = 3, T = 19.944000 C 15:36:54 Temperature Measurement, Probe Number = 4, T = 19.920000 C 15:36:54 Temperature Measurement, Probe Number = 5, T = 19.883000 C 15:36:54 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:36:54 Integrated Voltage Measurement... 15:37:17 Voltage Offset Correction: v_off_ini = -0.000001596 V, v_off_fin = -0.000002577 V 15:37:17 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158500990 Vs 15:37:17 Integrated Voltage Measurement... 15:37:39 Voltage Offset Correction: v_off_ini = -0.000001640 V, v_off_fin = -0.000000944 V 15:37:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444149 Vs 15:37:53 Temperature Measurement, Probe Number = 0, T = 20.298000 C 15:37:53 Temperature Measurement, Probe Number = 1, T = 19.928000 C 15:37:54 Temperature Measurement, Probe Number = 2, T = 19.948000 C 15:37:55 Temperature Measurement, Probe Number = 3, T = 19.951000 C 15:37:55 Temperature Measurement, Probe Number = 4, T = 19.920000 C 15:37:56 Temperature Measurement, Probe Number = 5, T = 19.883000 C 15:37:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.30 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:37:56 Integrated Voltage Measurement... 15:38:18 Voltage Offset Correction: v_off_ini = -0.000003843 V, v_off_fin = -0.000000505 V 15:38:18 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158487422 Vs 15:38:18 Integrated Voltage Measurement... 15:38:40 Voltage Offset Correction: v_off_ini = -0.000000366 V, v_off_fin = -0.000002972 V 15:38:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158452844 Vs 15:38:54 Temperature Measurement, Probe Number = 0, T = 20.266000 C 15:38:54 Temperature Measurement, Probe Number = 1, T = 19.930000 C 15:38:55 Temperature Measurement, Probe Number = 2, T = 19.948000 C 15:38:56 Temperature Measurement, Probe Number = 3, T = 19.949000 C 15:38:56 Temperature Measurement, Probe Number = 4, T = 19.921000 C 15:38:57 Temperature Measurement, Probe Number = 5, T = 19.884000 C 15:38:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.92 P6 = Top_Jaw, Value = 19.88 15:38:57 Integrated Voltage Measurement... 15:39:20 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = -0.000000835 V 15:39:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158490604 Vs 15:39:20 Integrated Voltage Measurement... 15:39:42 Voltage Offset Correction: v_off_ini = 0.000000974 V, v_off_fin = -0.000001061 V 15:39:42 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158488441 Vs 16:35:56 Temperature Measurement, Probe Number = 0, T = 20.044000 C 16:35:56 Temperature Measurement, Probe Number = 1, T = 19.925000 C 16:35:57 Temperature Measurement, Probe Number = 2, T = 19.955000 C 16:35:58 Temperature Measurement, Probe Number = 3, T = 19.937000 C 16:35:58 Temperature Measurement, Probe Number = 4, T = 19.933000 C 16:35:59 Temperature Measurement, Probe Number = 5, T = 19.886000 C 16:35:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:35:59 Integrated Voltage Measurement... 16:36:21 Voltage Offset Correction: v_off_ini = -0.000000702 V, v_off_fin = 0.000000702 V 16:36:21 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.158491827 Vs 16:36:21 Integrated Voltage Measurement... 16:36:43 Voltage Offset Correction: v_off_ini = 0.000002320 V, v_off_fin = -0.000001947 V 16:36:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158506123 Vs 16:36:57 Temperature Measurement, Probe Number = 0, T = 20.065000 C 16:36:57 Temperature Measurement, Probe Number = 1, T = 19.925000 C 16:36:58 Temperature Measurement, Probe Number = 2, T = 19.953000 C 16:36:59 Temperature Measurement, Probe Number = 3, T = 19.940000 C 16:36:59 Temperature Measurement, Probe Number = 4, T = 19.931000 C 16:37:00 Temperature Measurement, Probe Number = 5, T = 19.886000 C 16:37:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.95 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:37:00 Integrated Voltage Measurement... 16:37:24 Voltage Offset Correction: v_off_ini = 0.000000066 V, v_off_fin = 0.000002861 V 16:37:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158445727 Vs 16:37:24 Integrated Voltage Measurement... 16:37:46 Voltage Offset Correction: v_off_ini = -0.000001091 V, v_off_fin = -0.000003630 V 16:37:47 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468067 Vs 16:38:00 Temperature Measurement, Probe Number = 0, T = 20.070000 C 16:38:01 Temperature Measurement, Probe Number = 1, T = 19.928000 C 16:38:02 Temperature Measurement, Probe Number = 2, T = 19.957000 C 16:38:02 Temperature Measurement, Probe Number = 3, T = 19.937000 C 16:38:03 Temperature Measurement, Probe Number = 4, T = 19.933000 C 16:38:03 Temperature Measurement, Probe Number = 5, T = 19.889000 C 16:38:03 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:38:04 Integrated Voltage Measurement... 16:38:26 Voltage Offset Correction: v_off_ini = -0.000002188 V, v_off_fin = -0.000000029 V 16:38:26 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158487712 Vs 16:38:26 Integrated Voltage Measurement... 16:38:49 Voltage Offset Correction: v_off_ini = -0.000003300 V, v_off_fin = -0.000001888 V 16:38:49 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158452658 Vs 16:39:02 Temperature Measurement, Probe Number = 0, T = 20.050000 C 16:39:03 Temperature Measurement, Probe Number = 1, T = 19.925000 C 16:39:03 Temperature Measurement, Probe Number = 2, T = 19.957000 C 16:39:04 Temperature Measurement, Probe Number = 3, T = 19.937000 C 16:39:05 Temperature Measurement, Probe Number = 4, T = 19.934000 C 16:39:05 Temperature Measurement, Probe Number = 5, T = 19.887000 C 16:39:05 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:39:05 Integrated Voltage Measurement... 16:39:28 Voltage Offset Correction: v_off_ini = -0.000000988 V, v_off_fin = -0.000000490 V 16:39:28 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158484863 Vs 16:39:28 Integrated Voltage Measurement... 16:39:50 Voltage Offset Correction: v_off_ini = 0.000001288 V, v_off_fin = -0.000008408 V 16:39:50 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158440638 Vs 16:40:04 Temperature Measurement, Probe Number = 0, T = 20.057000 C 16:40:04 Temperature Measurement, Probe Number = 1, T = 19.928000 C 16:40:05 Temperature Measurement, Probe Number = 2, T = 19.959000 C 16:40:05 Temperature Measurement, Probe Number = 3, T = 19.939000 C 16:40:06 Temperature Measurement, Probe Number = 4, T = 19.935000 C 16:40:07 Temperature Measurement, Probe Number = 5, T = 19.888000 C 16:40:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:40:07 Integrated Voltage Measurement... 16:40:29 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = -0.000001441 V 16:40:29 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158498440 Vs 16:40:29 Integrated Voltage Measurement... 16:40:51 Voltage Offset Correction: v_off_ini = 0.000000227 V, v_off_fin = -0.000005767 V 16:40:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443821 Vs 16:41:05 Temperature Measurement, Probe Number = 0, T = 20.054000 C 16:41:05 Temperature Measurement, Probe Number = 1, T = 19.929000 C 16:41:06 Temperature Measurement, Probe Number = 2, T = 19.962000 C 16:41:07 Temperature Measurement, Probe Number = 3, T = 19.938000 C 16:41:07 Temperature Measurement, Probe Number = 4, T = 19.936000 C 16:41:08 Temperature Measurement, Probe Number = 5, T = 19.889000 C 16:41:08 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.89 16:41:08 Integrated Voltage Measurement... 16:41:30 Voltage Offset Correction: v_off_ini = -0.000001647 V, v_off_fin = -0.000002298 V 16:41:30 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158504951 Vs 16:41:30 Integrated Voltage Measurement... 16:41:52 Voltage Offset Correction: v_off_ini = -0.000000300 V, v_off_fin = -0.000003147 V 16:41:53 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448671 Vs 16:42:06 Temperature Measurement, Probe Number = 0, T = 20.032000 C 16:42:07 Temperature Measurement, Probe Number = 1, T = 19.928000 C 16:42:07 Temperature Measurement, Probe Number = 2, T = 19.960000 C 16:42:08 Temperature Measurement, Probe Number = 3, T = 19.939000 C 16:42:09 Temperature Measurement, Probe Number = 4, T = 19.934000 C 16:42:09 Temperature Measurement, Probe Number = 5, T = 19.887000 C 16:42:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:42:09 Integrated Voltage Measurement... 16:42:31 Voltage Offset Correction: v_off_ini = -0.000002313 V, v_off_fin = -0.000000710 V 16:42:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158499775 Vs 16:42:31 Integrated Voltage Measurement... 16:42:54 Voltage Offset Correction: v_off_ini = 0.000000900 V, v_off_fin = -0.000001237 V 16:42:54 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158477980 Vs 16:43:07 Temperature Measurement, Probe Number = 0, T = 20.010000 C 16:43:08 Temperature Measurement, Probe Number = 1, T = 19.932000 C 16:43:08 Temperature Measurement, Probe Number = 2, T = 19.961000 C 16:43:09 Temperature Measurement, Probe Number = 3, T = 19.938000 C 16:43:10 Temperature Measurement, Probe Number = 4, T = 19.936000 C 16:43:10 Temperature Measurement, Probe Number = 5, T = 19.889000 C 16:43:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.01 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.94 P6 = Top_Jaw, Value = 19.89 16:43:10 Integrated Voltage Measurement... 16:43:32 Voltage Offset Correction: v_off_ini = -0.000001061 V, v_off_fin = -0.000001157 V 16:43:32 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158496857 Vs 16:43:32 Integrated Voltage Measurement... 16:43:55 Voltage Offset Correction: v_off_ini = -0.000000490 V, v_off_fin = -0.000002108 V 16:43:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468790 Vs 16:44:08 Temperature Measurement, Probe Number = 0, T = 20.004000 C 16:44:09 Temperature Measurement, Probe Number = 1, T = 19.931000 C 16:44:09 Temperature Measurement, Probe Number = 2, T = 19.963000 C 16:44:10 Temperature Measurement, Probe Number = 3, T = 19.939000 C 16:44:11 Temperature Measurement, Probe Number = 4, T = 19.935000 C 16:44:11 Temperature Measurement, Probe Number = 5, T = 19.888000 C 16:44:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:44:11 Integrated Voltage Measurement... 16:44:33 Voltage Offset Correction: v_off_ini = -0.000002613 V, v_off_fin = -0.000000527 V 16:44:33 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158502421 Vs 16:44:33 Integrated Voltage Measurement... 16:44:56 Voltage Offset Correction: v_off_ini = 0.000003476 V, v_off_fin = -0.000001522 V 16:44:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158515338 Vs 16:45:09 Temperature Measurement, Probe Number = 0, T = 20.003000 C 16:45:10 Temperature Measurement, Probe Number = 1, T = 19.930000 C 16:45:10 Temperature Measurement, Probe Number = 2, T = 19.962000 C 16:45:11 Temperature Measurement, Probe Number = 3, T = 19.939000 C 16:45:12 Temperature Measurement, Probe Number = 4, T = 19.935000 C 16:45:12 Temperature Measurement, Probe Number = 5, T = 19.888000 C 16:45:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.93 P3 = Bottom_DS_Module, Value = 19.96 P4 = Encode_Arm, Value = 19.94 P5 = Bottom_Jaw, Value = 19.93 P6 = Top_Jaw, Value = 19.89 16:45:12 Integrated Voltage Measurement... 16:45:34 Voltage Offset Correction: v_off_ini = -0.000003118 V, v_off_fin = -0.000002334 V 16:45:35 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158536314 Vs 16:45:35 Integrated Voltage Measurement... 16:45:57 Voltage Offset Correction: v_off_ini = -0.000000483 V, v_off_fin = -0.000002459 V 16:45:57 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468092 Vs 17:42:11 Temperature Measurement, Probe Number = 0, T = 20.055000 C 17:42:11 Temperature Measurement, Probe Number = 1, T = 19.946000 C 17:42:12 Temperature Measurement, Probe Number = 2, T = 19.981000 C 17:42:12 Temperature Measurement, Probe Number = 3, T = 19.957000 C 17:42:13 Temperature Measurement, Probe Number = 4, T = 19.956000 C 17:42:14 Temperature Measurement, Probe Number = 5, T = 19.904000 C 17:42:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.90 17:42:14 Integrated Voltage Measurement... 17:42:36 Voltage Offset Correction: v_off_ini = -0.000000117 V, v_off_fin = 0.000001770 V 17:42:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158504927 Vs 17:42:36 Integrated Voltage Measurement... 17:42:59 Voltage Offset Correction: v_off_ini = -0.000001214 V, v_off_fin = -0.000002136 V 17:42:59 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158460150 Vs 17:43:12 Temperature Measurement, Probe Number = 0, T = 20.086000 C 17:43:13 Temperature Measurement, Probe Number = 1, T = 19.945000 C 17:43:13 Temperature Measurement, Probe Number = 2, T = 19.980000 C 17:43:14 Temperature Measurement, Probe Number = 3, T = 19.958000 C 17:43:15 Temperature Measurement, Probe Number = 4, T = 19.956000 C 17:43:15 Temperature Measurement, Probe Number = 5, T = 19.903000 C 17:43:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.90 17:43:15 Integrated Voltage Measurement... 17:43:37 Voltage Offset Correction: v_off_ini = -0.000001580 V, v_off_fin = 0.000002312 V 17:43:37 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158457070 Vs 17:43:37 Integrated Voltage Measurement... 17:44:00 Voltage Offset Correction: v_off_ini = -0.000000051 V, v_off_fin = -0.000001492 V 17:44:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158470708 Vs 17:44:13 Temperature Measurement, Probe Number = 0, T = 20.139000 C 17:44:14 Temperature Measurement, Probe Number = 1, T = 19.949000 C 17:44:14 Temperature Measurement, Probe Number = 2, T = 19.986000 C 17:44:15 Temperature Measurement, Probe Number = 3, T = 19.959000 C 17:44:16 Temperature Measurement, Probe Number = 4, T = 19.959000 C 17:44:16 Temperature Measurement, Probe Number = 5, T = 19.906000 C 17:44:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.91 17:44:16 Integrated Voltage Measurement... 17:44:38 Voltage Offset Correction: v_off_ini = 0.000001031 V, v_off_fin = -0.000003818 V 17:44:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158476647 Vs 17:44:38 Integrated Voltage Measurement... 17:45:01 Voltage Offset Correction: v_off_ini = -0.000000468 V, v_off_fin = -0.000002019 V 17:45:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158480856 Vs 17:45:14 Temperature Measurement, Probe Number = 0, T = 20.139000 C 17:45:15 Temperature Measurement, Probe Number = 1, T = 19.944000 C 17:45:15 Temperature Measurement, Probe Number = 2, T = 19.982000 C 17:45:16 Temperature Measurement, Probe Number = 3, T = 19.961000 C 17:45:17 Temperature Measurement, Probe Number = 4, T = 19.957000 C 17:45:17 Temperature Measurement, Probe Number = 5, T = 19.904000 C 17:45:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.90 17:45:17 Integrated Voltage Measurement... 17:45:39 Voltage Offset Correction: v_off_ini = -0.000000614 V, v_off_fin = -0.000000863 V 17:45:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158477037 Vs 17:45:39 Integrated Voltage Measurement... 17:46:02 Voltage Offset Correction: v_off_ini = -0.000000344 V, v_off_fin = -0.000002750 V 17:46:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468374 Vs 17:46:15 Temperature Measurement, Probe Number = 0, T = 20.075000 C 17:46:16 Temperature Measurement, Probe Number = 1, T = 19.942000 C 17:46:16 Temperature Measurement, Probe Number = 2, T = 19.982000 C 17:46:17 Temperature Measurement, Probe Number = 3, T = 19.958000 C 17:46:18 Temperature Measurement, Probe Number = 4, T = 19.956000 C 17:46:18 Temperature Measurement, Probe Number = 5, T = 19.904000 C 17:46:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.94 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.90 17:46:18 Integrated Voltage Measurement... 17:46:47 Voltage Offset Correction: v_off_ini = -0.000000622 V, v_off_fin = -0.000005078 V 17:46:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158521458 Vs 17:46:47 Integrated Voltage Measurement... 17:47:09 Voltage Offset Correction: v_off_ini = -0.000000410 V, v_off_fin = -0.000003746 V 17:47:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158468047 Vs 17:47:23 Temperature Measurement, Probe Number = 0, T = 20.072000 C 17:47:23 Temperature Measurement, Probe Number = 1, T = 19.948000 C 17:47:24 Temperature Measurement, Probe Number = 2, T = 19.987000 C 17:47:24 Temperature Measurement, Probe Number = 3, T = 19.957000 C 17:47:25 Temperature Measurement, Probe Number = 4, T = 19.960000 C 17:47:26 Temperature Measurement, Probe Number = 5, T = 19.906000 C 17:47:26 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.91 17:47:26 Integrated Voltage Measurement... 17:47:48 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000004655 V 17:47:48 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158530315 Vs 17:47:48 Integrated Voltage Measurement... 17:48:11 Voltage Offset Correction: v_off_ini = -0.000001675 V, v_off_fin = -0.000003746 V 17:48:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447885 Vs 17:48:25 Temperature Measurement, Probe Number = 0, T = 20.098000 C 17:48:25 Temperature Measurement, Probe Number = 1, T = 19.950000 C 17:48:26 Temperature Measurement, Probe Number = 2, T = 19.990000 C 17:48:27 Temperature Measurement, Probe Number = 3, T = 19.958000 C 17:48:27 Temperature Measurement, Probe Number = 4, T = 19.960000 C 17:48:28 Temperature Measurement, Probe Number = 5, T = 19.905000 C 17:48:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.91 17:48:28 Integrated Voltage Measurement... 17:48:50 Voltage Offset Correction: v_off_ini = -0.000002298 V, v_off_fin = 0.000003015 V 17:48:50 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158482553 Vs 17:48:50 Integrated Voltage Measurement... 17:49:13 Voltage Offset Correction: v_off_ini = -0.000004538 V, v_off_fin = -0.000004392 V 17:49:13 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158432905 Vs 17:49:26 Temperature Measurement, Probe Number = 0, T = 20.091000 C 17:49:27 Temperature Measurement, Probe Number = 1, T = 19.950000 C 17:49:28 Temperature Measurement, Probe Number = 2, T = 19.985000 C 17:49:28 Temperature Measurement, Probe Number = 3, T = 19.956000 C 17:49:29 Temperature Measurement, Probe Number = 4, T = 19.959000 C 17:49:29 Temperature Measurement, Probe Number = 5, T = 19.904000 C 17:49:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.98 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.90 17:49:29 Integrated Voltage Measurement... 17:49:52 Voltage Offset Correction: v_off_ini = -0.000002129 V, v_off_fin = -0.000001588 V 17:49:52 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158489502 Vs 17:49:52 Integrated Voltage Measurement... 17:50:14 Voltage Offset Correction: v_off_ini = 0.000000117 V, v_off_fin = -0.000003044 V 17:50:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158486046 Vs 17:50:27 Temperature Measurement, Probe Number = 0, T = 20.061000 C 17:50:28 Temperature Measurement, Probe Number = 1, T = 19.950000 C 17:50:29 Temperature Measurement, Probe Number = 2, T = 19.987000 C 17:50:29 Temperature Measurement, Probe Number = 3, T = 19.955000 C 17:50:30 Temperature Measurement, Probe Number = 4, T = 19.959000 C 17:50:30 Temperature Measurement, Probe Number = 5, T = 19.906000 C 17:50:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.95 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.91 17:50:30 Integrated Voltage Measurement... 17:50:53 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000702 V 17:50:53 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158477102 Vs 17:50:53 Integrated Voltage Measurement... 17:51:15 Voltage Offset Correction: v_off_ini = -0.000001976 V, v_off_fin = 0.000001368 V 17:51:15 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158475584 Vs 17:51:29 Temperature Measurement, Probe Number = 0, T = 20.081000 C 17:51:29 Temperature Measurement, Probe Number = 1, T = 19.947000 C 17:51:30 Temperature Measurement, Probe Number = 2, T = 19.987000 C 17:51:31 Temperature Measurement, Probe Number = 3, T = 19.957000 C 17:51:31 Temperature Measurement, Probe Number = 4, T = 19.961000 C 17:51:32 Temperature Measurement, Probe Number = 5, T = 19.906000 C 17:51:32 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 19.99 P4 = Encode_Arm, Value = 19.96 P5 = Bottom_Jaw, Value = 19.96 P6 = Top_Jaw, Value = 19.91 17:51:32 Integrated Voltage Measurement... 17:51:54 Voltage Offset Correction: v_off_ini = -0.000001471 V, v_off_fin = 0.000000790 V 17:51:54 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158477205 Vs 17:51:54 Integrated Voltage Measurement... 17:52:16 Voltage Offset Correction: v_off_ini = 0.000002452 V, v_off_fin = -0.000002803 V 17:52:17 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158513285 Vs 18:48:30 Temperature Measurement, Probe Number = 0, T = 20.095000 C 18:48:31 Temperature Measurement, Probe Number = 1, T = 19.957000 C 18:48:31 Temperature Measurement, Probe Number = 2, T = 19.998000 C 18:48:32 Temperature Measurement, Probe Number = 3, T = 19.975000 C 18:48:32 Temperature Measurement, Probe Number = 4, T = 19.975000 C 18:48:33 Temperature Measurement, Probe Number = 5, T = 19.914000 C 18:48:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.91 18:48:33 Integrated Voltage Measurement... 18:48:55 Voltage Offset Correction: v_off_ini = -0.000000241 V, v_off_fin = 0.000001990 V 18:48:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158509134 Vs 18:48:55 Integrated Voltage Measurement... 18:49:17 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = -0.000001696 V 18:49:17 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158492336 Vs 18:49:31 Temperature Measurement, Probe Number = 0, T = 20.098000 C 18:49:32 Temperature Measurement, Probe Number = 1, T = 19.955000 C 18:49:32 Temperature Measurement, Probe Number = 2, T = 20.000000 C 18:49:33 Temperature Measurement, Probe Number = 3, T = 19.975000 C 18:49:33 Temperature Measurement, Probe Number = 4, T = 19.974000 C 18:49:34 Temperature Measurement, Probe Number = 5, T = 19.914000 C 18:49:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.97 P6 = Top_Jaw, Value = 19.91 18:49:34 Integrated Voltage Measurement... 18:49:56 Voltage Offset Correction: v_off_ini = -0.000000497 V, v_off_fin = 0.000001726 V 18:49:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158490860 Vs 18:49:56 Integrated Voltage Measurement... 18:50:19 Voltage Offset Correction: v_off_ini = 0.000000651 V, v_off_fin = -0.000003729 V 18:50:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158476822 Vs 18:50:32 Temperature Measurement, Probe Number = 0, T = 20.065000 C 18:50:33 Temperature Measurement, Probe Number = 1, T = 19.955000 C 18:50:33 Temperature Measurement, Probe Number = 2, T = 20.001000 C 18:50:34 Temperature Measurement, Probe Number = 3, T = 19.973000 C 18:50:35 Temperature Measurement, Probe Number = 4, T = 19.975000 C 18:50:35 Temperature Measurement, Probe Number = 5, T = 19.915000 C 18:50:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.95 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.91 18:50:35 Integrated Voltage Measurement... 18:50:57 Voltage Offset Correction: v_off_ini = -0.000002165 V, v_off_fin = 0.000000563 V 18:50:58 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158480894 Vs 18:50:58 Integrated Voltage Measurement... 18:51:20 Voltage Offset Correction: v_off_ini = -0.000002340 V, v_off_fin = -0.000002618 V 18:51:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158477078 Vs 18:51:34 Temperature Measurement, Probe Number = 0, T = 20.048000 C 18:51:34 Temperature Measurement, Probe Number = 1, T = 19.958000 C 18:51:35 Temperature Measurement, Probe Number = 2, T = 20.002000 C 18:51:35 Temperature Measurement, Probe Number = 3, T = 19.972000 C 18:51:36 Temperature Measurement, Probe Number = 4, T = 19.977000 C 18:51:37 Temperature Measurement, Probe Number = 5, T = 19.915000 C 18:51:37 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.91 18:51:37 Integrated Voltage Measurement... 18:51:59 Voltage Offset Correction: v_off_ini = -0.000001689 V, v_off_fin = 0.000000585 V 18:51:59 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158499247 Vs 18:51:59 Integrated Voltage Measurement... 18:52:22 Voltage Offset Correction: v_off_ini = -0.000000826 V, v_off_fin = -0.000001879 V 18:52:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158486579 Vs 18:52:36 Temperature Measurement, Probe Number = 0, T = 20.068000 C 18:52:36 Temperature Measurement, Probe Number = 1, T = 19.961000 C 18:52:37 Temperature Measurement, Probe Number = 2, T = 20.001000 C 18:52:38 Temperature Measurement, Probe Number = 3, T = 19.973000 C 18:52:38 Temperature Measurement, Probe Number = 4, T = 19.977000 C 18:52:39 Temperature Measurement, Probe Number = 5, T = 19.917000 C 18:52:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.07 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:52:39 Integrated Voltage Measurement... 18:53:01 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = 0.000002553 V 18:53:02 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158471426 Vs 18:53:02 Integrated Voltage Measurement... 18:53:24 Voltage Offset Correction: v_off_ini = -0.000000643 V, v_off_fin = -0.000004044 V 18:53:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158473910 Vs 18:53:38 Temperature Measurement, Probe Number = 0, T = 20.088000 C 18:53:39 Temperature Measurement, Probe Number = 1, T = 19.963000 C 18:53:39 Temperature Measurement, Probe Number = 2, T = 20.003000 C 18:53:40 Temperature Measurement, Probe Number = 3, T = 19.971000 C 18:53:40 Temperature Measurement, Probe Number = 4, T = 19.979000 C 18:53:41 Temperature Measurement, Probe Number = 5, T = 19.918000 C 18:53:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:53:41 Integrated Voltage Measurement... 18:54:03 Voltage Offset Correction: v_off_ini = -0.000002618 V, v_off_fin = -0.000001375 V 18:54:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158522705 Vs 18:54:03 Integrated Voltage Measurement... 18:54:26 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001667 V 18:54:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158462070 Vs 18:54:40 Temperature Measurement, Probe Number = 0, T = 20.082000 C 18:54:40 Temperature Measurement, Probe Number = 1, T = 19.958000 C 18:54:41 Temperature Measurement, Probe Number = 2, T = 20.000000 C 18:54:42 Temperature Measurement, Probe Number = 3, T = 19.971000 C 18:54:42 Temperature Measurement, Probe Number = 4, T = 19.976000 C 18:54:43 Temperature Measurement, Probe Number = 5, T = 19.916000 C 18:54:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.08 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:54:43 Integrated Voltage Measurement... 18:55:05 Voltage Offset Correction: v_off_ini = -0.000001046 V, v_off_fin = -0.000000702 V 18:55:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158486912 Vs 18:55:05 Integrated Voltage Measurement... 18:55:28 Voltage Offset Correction: v_off_ini = 0.000001170 V, v_off_fin = -0.000001916 V 18:55:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158484184 Vs 18:55:41 Temperature Measurement, Probe Number = 0, T = 20.058000 C 18:55:42 Temperature Measurement, Probe Number = 1, T = 19.958000 C 18:55:42 Temperature Measurement, Probe Number = 2, T = 19.999000 C 18:55:43 Temperature Measurement, Probe Number = 3, T = 19.971000 C 18:55:44 Temperature Measurement, Probe Number = 4, T = 19.977000 C 18:55:44 Temperature Measurement, Probe Number = 5, T = 19.917000 C 18:55:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.06 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:55:44 Integrated Voltage Measurement... 18:56:06 Voltage Offset Correction: v_off_ini = -0.000001623 V, v_off_fin = -0.000000819 V 18:56:06 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158513839 Vs 18:56:06 Integrated Voltage Measurement... 18:56:29 Voltage Offset Correction: v_off_ini = -0.000001806 V, v_off_fin = -0.000001280 V 18:56:30 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158474046 Vs 18:56:43 Temperature Measurement, Probe Number = 0, T = 20.021000 C 18:56:44 Temperature Measurement, Probe Number = 1, T = 19.959000 C 18:56:44 Temperature Measurement, Probe Number = 2, T = 20.002000 C 18:56:45 Temperature Measurement, Probe Number = 3, T = 19.974000 C 18:56:46 Temperature Measurement, Probe Number = 4, T = 19.977000 C 18:56:46 Temperature Measurement, Probe Number = 5, T = 19.917000 C 18:56:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.02 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:56:46 Integrated Voltage Measurement... 18:57:08 Voltage Offset Correction: v_off_ini = 0.000000929 V, v_off_fin = -0.000004667 V 18:57:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158517616 Vs 18:57:08 Integrated Voltage Measurement... 18:57:31 Voltage Offset Correction: v_off_ini = -0.000002077 V, v_off_fin = -0.000001163 V 18:57:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158462665 Vs 18:57:44 Temperature Measurement, Probe Number = 0, T = 20.031000 C 18:57:45 Temperature Measurement, Probe Number = 1, T = 19.957000 C 18:57:45 Temperature Measurement, Probe Number = 2, T = 20.004000 C 18:57:46 Temperature Measurement, Probe Number = 3, T = 19.973000 C 18:57:47 Temperature Measurement, Probe Number = 4, T = 19.977000 C 18:57:47 Temperature Measurement, Probe Number = 5, T = 19.917000 C 18:57:47 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.00 P4 = Encode_Arm, Value = 19.97 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 18:57:47 Integrated Voltage Measurement... 18:58:09 Voltage Offset Correction: v_off_ini = -0.000002362 V, v_off_fin = 0.000001148 V 18:58:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158480100 Vs 18:58:09 Integrated Voltage Measurement... 18:58:32 Voltage Offset Correction: v_off_ini = 0.000001492 V, v_off_fin = -0.000003014 V 18:58:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158519541 Vs 19:54:45 Temperature Measurement, Probe Number = 0, T = 20.052000 C 19:54:46 Temperature Measurement, Probe Number = 1, T = 19.969000 C 19:54:46 Temperature Measurement, Probe Number = 2, T = 20.015000 C 19:54:47 Temperature Measurement, Probe Number = 3, T = 19.984000 C 19:54:48 Temperature Measurement, Probe Number = 4, T = 19.991000 C 19:54:48 Temperature Measurement, Probe Number = 5, T = 19.928000 C 19:54:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.05 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 19:54:48 Integrated Voltage Measurement... 19:55:12 Voltage Offset Correction: v_off_ini = 0.000002319 V, v_off_fin = 0.000000468 V 19:55:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.158513871 Vs 19:55:12 Integrated Voltage Measurement... 19:55:34 Voltage Offset Correction: v_off_ini = -0.000001931 V, v_off_fin = -0.000001866 V 19:55:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158491724 Vs 19:55:48 Temperature Measurement, Probe Number = 0, T = 19.996000 C 19:55:48 Temperature Measurement, Probe Number = 1, T = 19.966000 C 19:55:49 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:55:50 Temperature Measurement, Probe Number = 3, T = 19.981000 C 19:55:50 Temperature Measurement, Probe Number = 4, T = 19.987000 C 19:55:51 Temperature Measurement, Probe Number = 5, T = 19.925000 C 19:55:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 19:55:51 Integrated Voltage Measurement... 19:56:13 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000000205 V 19:56:13 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158496478 Vs 19:56:13 Integrated Voltage Measurement... 19:56:36 Voltage Offset Correction: v_off_ini = -0.000000790 V, v_off_fin = -0.000003132 V 19:56:36 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158471470 Vs 19:56:49 Temperature Measurement, Probe Number = 0, T = 19.973000 C 19:56:50 Temperature Measurement, Probe Number = 1, T = 19.962000 C 19:56:50 Temperature Measurement, Probe Number = 2, T = 20.008000 C 19:56:51 Temperature Measurement, Probe Number = 3, T = 19.979000 C 19:56:52 Temperature Measurement, Probe Number = 4, T = 19.985000 C 19:56:52 Temperature Measurement, Probe Number = 5, T = 19.922000 C 19:56:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 19:56:52 Integrated Voltage Measurement... 19:57:14 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000004296 V 19:57:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158553169 Vs 19:57:14 Integrated Voltage Measurement... 19:57:37 Voltage Offset Correction: v_off_ini = -0.000002956 V, v_off_fin = -0.000004463 V 19:57:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440419 Vs 19:57:50 Temperature Measurement, Probe Number = 0, T = 19.960000 C 19:57:51 Temperature Measurement, Probe Number = 1, T = 19.959000 C 19:57:51 Temperature Measurement, Probe Number = 2, T = 20.010000 C 19:57:52 Temperature Measurement, Probe Number = 3, T = 19.977000 C 19:57:53 Temperature Measurement, Probe Number = 4, T = 19.985000 C 19:57:53 Temperature Measurement, Probe Number = 5, T = 19.922000 C 19:57:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.96 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.98 P6 = Top_Jaw, Value = 19.92 19:57:53 Integrated Voltage Measurement... 19:58:15 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000000439 V 19:58:15 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158488445 Vs 19:58:15 Integrated Voltage Measurement... 19:58:38 Voltage Offset Correction: v_off_ini = 0.000000000 V, v_off_fin = 0.000001156 V 19:58:38 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158497388 Vs 19:58:52 Temperature Measurement, Probe Number = 0, T = 19.948000 C 19:58:52 Temperature Measurement, Probe Number = 1, T = 19.968000 C 19:58:53 Temperature Measurement, Probe Number = 2, T = 20.011000 C 19:58:53 Temperature Measurement, Probe Number = 3, T = 19.979000 C 19:58:54 Temperature Measurement, Probe Number = 4, T = 19.989000 C 19:58:55 Temperature Measurement, Probe Number = 5, T = 19.925000 C 19:58:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.95 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 19:58:55 Integrated Voltage Measurement... 19:59:17 Voltage Offset Correction: v_off_ini = -0.000001127 V, v_off_fin = -0.000001931 V 19:59:17 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158506824 Vs 19:59:17 Integrated Voltage Measurement... 19:59:39 Voltage Offset Correction: v_off_ini = -0.000002342 V, v_off_fin = -0.000001778 V 19:59:39 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158468954 Vs 19:59:53 Temperature Measurement, Probe Number = 0, T = 19.973000 C 19:59:53 Temperature Measurement, Probe Number = 1, T = 19.964000 C 19:59:54 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:59:54 Temperature Measurement, Probe Number = 3, T = 19.979000 C 19:59:55 Temperature Measurement, Probe Number = 4, T = 19.991000 C 19:59:56 Temperature Measurement, Probe Number = 5, T = 19.924000 C 19:59:56 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 19.97 P2 = Top_US_Module, Value = 19.96 P3 = Bottom_DS_Module, Value = 20.01 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.92 19:59:56 Integrated Voltage Measurement... 20:00:18 Voltage Offset Correction: v_off_ini = -0.000001068 V, v_off_fin = -0.000001237 V 20:00:18 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158502201 Vs 20:00:18 Integrated Voltage Measurement... 20:00:41 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = -0.000000622 V 20:00:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158499047 Vs 20:00:54 Temperature Measurement, Probe Number = 0, T = 19.998000 C 20:00:55 Temperature Measurement, Probe Number = 1, T = 19.967000 C 20:00:55 Temperature Measurement, Probe Number = 2, T = 20.018000 C 20:00:56 Temperature Measurement, Probe Number = 3, T = 19.979000 C 20:00:57 Temperature Measurement, Probe Number = 4, T = 19.991000 C 20:00:57 Temperature Measurement, Probe Number = 5, T = 19.928000 C 20:00:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.00 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 20:00:57 Integrated Voltage Measurement... 20:01:19 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = 0.000007074 V 20:01:19 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158438887 Vs 20:01:19 Integrated Voltage Measurement... 20:01:42 Voltage Offset Correction: v_off_ini = -0.000005245 V, v_off_fin = -0.000002019 V 20:01:42 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158446326 Vs 20:01:55 Temperature Measurement, Probe Number = 0, T = 20.038000 C 20:01:56 Temperature Measurement, Probe Number = 1, T = 19.970000 C 20:01:57 Temperature Measurement, Probe Number = 2, T = 20.022000 C 20:01:57 Temperature Measurement, Probe Number = 3, T = 19.981000 C 20:01:58 Temperature Measurement, Probe Number = 4, T = 19.994000 C 20:01:58 Temperature Measurement, Probe Number = 5, T = 19.929000 C 20:01:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.04 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 20:01:58 Integrated Voltage Measurement... 20:02:21 Voltage Offset Correction: v_off_ini = -0.000001639 V, v_off_fin = -0.000006475 V 20:02:21 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158562540 Vs 20:02:21 Integrated Voltage Measurement... 20:02:43 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000004514 V 20:02:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158474926 Vs 20:02:56 Temperature Measurement, Probe Number = 0, T = 20.027000 C 20:02:57 Temperature Measurement, Probe Number = 1, T = 19.973000 C 20:02:58 Temperature Measurement, Probe Number = 2, T = 20.021000 C 20:02:58 Temperature Measurement, Probe Number = 3, T = 19.983000 C 20:02:59 Temperature Measurement, Probe Number = 4, T = 19.995000 C 20:02:59 Temperature Measurement, Probe Number = 5, T = 19.929000 C 20:02:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 20.00 P6 = Top_Jaw, Value = 19.93 20:02:59 Integrated Voltage Measurement... 20:03:22 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = 0.000000563 V 20:03:22 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158489161 Vs 20:03:22 Integrated Voltage Measurement... 20:03:44 Voltage Offset Correction: v_off_ini = 0.000001083 V, v_off_fin = -0.000004009 V 20:03:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158480099 Vs 20:03:58 Temperature Measurement, Probe Number = 0, T = 20.026000 C 20:03:58 Temperature Measurement, Probe Number = 1, T = 19.969000 C 20:03:59 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:04:00 Temperature Measurement, Probe Number = 3, T = 19.981000 C 20:04:00 Temperature Measurement, Probe Number = 4, T = 19.992000 C 20:04:01 Temperature Measurement, Probe Number = 5, T = 19.926000 C 20:04:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.03 P2 = Top_US_Module, Value = 19.97 P3 = Bottom_DS_Module, Value = 20.02 P4 = Encode_Arm, Value = 19.98 P5 = Bottom_Jaw, Value = 19.99 P6 = Top_Jaw, Value = 19.93 20:04:01 Integrated Voltage Measurement... 20:04:23 Voltage Offset Correction: v_off_ini = -0.000002341 V, v_off_fin = -0.000002831 V 20:04:23 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158526965 Vs 20:04:23 Integrated Voltage Measurement... 20:04:46 Voltage Offset Correction: v_off_ini = -0.000000351 V, v_off_fin = -0.000002926 V 20:04:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158486704 Vs 21:00:59 Temperature Measurement, Probe Number = 0, T = 20.205000 C 21:01:00 Temperature Measurement, Probe Number = 1, T = 19.986000 C 21:01:00 Temperature Measurement, Probe Number = 2, T = 20.039000 C 21:01:01 Temperature Measurement, Probe Number = 3, T = 20.014000 C 21:01:02 Temperature Measurement, Probe Number = 4, T = 20.016000 C 21:01:02 Temperature Measurement, Probe Number = 5, T = 19.946000 C 21:01:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:01:02 Integrated Voltage Measurement... 21:01:31 Voltage Offset Correction: v_off_ini = -0.000000571 V, v_off_fin = -0.000002056 V 21:01:31 Integrated Voltage Measurement Delta Gap = 0.0040017 m VT = 0.158562279 Vs 21:01:31 Integrated Voltage Measurement... 21:01:54 Voltage Offset Correction: v_off_ini = -0.000001120 V, v_off_fin = -0.000003220 V 21:01:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158473927 Vs 21:02:07 Temperature Measurement, Probe Number = 0, T = 20.156000 C 21:02:08 Temperature Measurement, Probe Number = 1, T = 19.981000 C 21:02:08 Temperature Measurement, Probe Number = 2, T = 20.030000 C 21:02:09 Temperature Measurement, Probe Number = 3, T = 20.015000 C 21:02:10 Temperature Measurement, Probe Number = 4, T = 20.011000 C 21:02:10 Temperature Measurement, Probe Number = 5, T = 19.944000 C 21:02:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 20.03 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.94 21:02:10 Integrated Voltage Measurement... 21:02:32 Voltage Offset Correction: v_off_ini = -0.000002320 V, v_off_fin = -0.000000834 V 21:02:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158490654 Vs 21:02:32 Integrated Voltage Measurement... 21:02:55 Voltage Offset Correction: v_off_ini = 0.000000790 V, v_off_fin = -0.000001039 V 21:02:55 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158473848 Vs 21:03:09 Temperature Measurement, Probe Number = 0, T = 20.166000 C 21:03:10 Temperature Measurement, Probe Number = 1, T = 19.984000 C 21:03:10 Temperature Measurement, Probe Number = 2, T = 20.036000 C 21:03:11 Temperature Measurement, Probe Number = 3, T = 20.014000 C 21:03:11 Temperature Measurement, Probe Number = 4, T = 20.013000 C 21:03:12 Temperature Measurement, Probe Number = 5, T = 19.946000 C 21:03:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.01 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.95 21:03:12 Integrated Voltage Measurement... 21:03:34 Voltage Offset Correction: v_off_ini = -0.000001449 V, v_off_fin = -0.000000644 V 21:03:34 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158485715 Vs 21:03:34 Integrated Voltage Measurement... 21:03:58 Voltage Offset Correction: v_off_ini = 0.000001639 V, v_off_fin = 0.000002012 V 21:03:58 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158538856 Vs 21:04:12 Temperature Measurement, Probe Number = 0, T = 20.163000 C 21:04:13 Temperature Measurement, Probe Number = 1, T = 19.985000 C 21:04:13 Temperature Measurement, Probe Number = 2, T = 20.039000 C 21:04:14 Temperature Measurement, Probe Number = 3, T = 20.016000 C 21:04:14 Temperature Measurement, Probe Number = 4, T = 20.013000 C 21:04:15 Temperature Measurement, Probe Number = 5, T = 19.946000 C 21:04:15 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 19.98 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.01 P6 = Top_Jaw, Value = 19.95 21:04:15 Integrated Voltage Measurement... 21:04:37 Voltage Offset Correction: v_off_ini = 0.000000234 V, v_off_fin = -0.000002956 V 21:04:37 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.158498840 Vs 21:04:37 Integrated Voltage Measurement... 21:05:00 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = -0.000002495 V 21:05:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158465937 Vs 21:05:13 Temperature Measurement, Probe Number = 0, T = 20.182000 C 21:05:14 Temperature Measurement, Probe Number = 1, T = 19.987000 C 21:05:14 Temperature Measurement, Probe Number = 2, T = 20.040000 C 21:05:15 Temperature Measurement, Probe Number = 3, T = 20.017000 C 21:05:16 Temperature Measurement, Probe Number = 4, T = 20.016000 C 21:05:16 Temperature Measurement, Probe Number = 5, T = 19.947000 C 21:05:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:05:16 Integrated Voltage Measurement... 21:05:39 Voltage Offset Correction: v_off_ini = -0.000001859 V, v_off_fin = -0.000001178 V 21:05:39 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158511297 Vs 21:05:39 Integrated Voltage Measurement... 21:06:02 Voltage Offset Correction: v_off_ini = -0.000001390 V, v_off_fin = -0.000002019 V 21:06:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158466758 Vs 21:06:15 Temperature Measurement, Probe Number = 0, T = 20.195000 C 21:06:16 Temperature Measurement, Probe Number = 1, T = 19.989000 C 21:06:16 Temperature Measurement, Probe Number = 2, T = 20.043000 C 21:06:17 Temperature Measurement, Probe Number = 3, T = 20.016000 C 21:06:18 Temperature Measurement, Probe Number = 4, T = 20.018000 C 21:06:18 Temperature Measurement, Probe Number = 5, T = 19.950000 C 21:06:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:06:18 Integrated Voltage Measurement... 21:06:40 Voltage Offset Correction: v_off_ini = -0.000001881 V, v_off_fin = -0.000001676 V 21:06:40 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158509716 Vs 21:06:40 Integrated Voltage Measurement... 21:07:03 Voltage Offset Correction: v_off_ini = 0.000001061 V, v_off_fin = -0.000000564 V 21:07:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158493468 Vs 21:07:16 Temperature Measurement, Probe Number = 0, T = 20.176000 C 21:07:17 Temperature Measurement, Probe Number = 1, T = 19.990000 C 21:07:17 Temperature Measurement, Probe Number = 2, T = 20.046000 C 21:07:18 Temperature Measurement, Probe Number = 3, T = 20.019000 C 21:07:19 Temperature Measurement, Probe Number = 4, T = 20.018000 C 21:07:19 Temperature Measurement, Probe Number = 5, T = 19.950000 C 21:07:19 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:07:19 Integrated Voltage Measurement... 21:07:41 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001090 V 21:07:41 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158499001 Vs 21:07:41 Integrated Voltage Measurement... 21:08:04 Voltage Offset Correction: v_off_ini = -0.000001068 V, v_off_fin = -0.000000995 V 21:08:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158489167 Vs 21:08:18 Temperature Measurement, Probe Number = 0, T = 20.198000 C 21:08:18 Temperature Measurement, Probe Number = 1, T = 19.992000 C 21:08:19 Temperature Measurement, Probe Number = 2, T = 20.047000 C 21:08:20 Temperature Measurement, Probe Number = 3, T = 20.021000 C 21:08:20 Temperature Measurement, Probe Number = 4, T = 20.019000 C 21:08:21 Temperature Measurement, Probe Number = 5, T = 19.951000 C 21:08:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:08:21 Integrated Voltage Measurement... 21:08:43 Voltage Offset Correction: v_off_ini = -0.000002957 V, v_off_fin = 0.000001390 V 21:08:43 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158492547 Vs 21:08:43 Integrated Voltage Measurement... 21:09:05 Voltage Offset Correction: v_off_ini = 0.000001580 V, v_off_fin = -0.000002333 V 21:09:05 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158509070 Vs 21:09:19 Temperature Measurement, Probe Number = 0, T = 20.210000 C 21:09:19 Temperature Measurement, Probe Number = 1, T = 19.994000 C 21:09:20 Temperature Measurement, Probe Number = 2, T = 20.048000 C 21:09:21 Temperature Measurement, Probe Number = 3, T = 20.020000 C 21:09:21 Temperature Measurement, Probe Number = 4, T = 20.021000 C 21:09:22 Temperature Measurement, Probe Number = 5, T = 19.952000 C 21:09:22 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.05 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:09:22 Integrated Voltage Measurement... 21:09:44 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = -0.000002583 V 21:09:44 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158509141 Vs 21:09:44 Integrated Voltage Measurement... 21:10:06 Voltage Offset Correction: v_off_ini = 0.000000197 V, v_off_fin = -0.000003518 V 21:10:06 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158484470 Vs 21:10:20 Temperature Measurement, Probe Number = 0, T = 20.206000 C 21:10:21 Temperature Measurement, Probe Number = 1, T = 19.992000 C 21:10:21 Temperature Measurement, Probe Number = 2, T = 20.044000 C 21:10:22 Temperature Measurement, Probe Number = 3, T = 20.020000 C 21:10:22 Temperature Measurement, Probe Number = 4, T = 20.020000 C 21:10:23 Temperature Measurement, Probe Number = 5, T = 19.950000 C 21:10:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.21 P2 = Top_US_Module, Value = 19.99 P3 = Bottom_DS_Module, Value = 20.04 P4 = Encode_Arm, Value = 20.02 P5 = Bottom_Jaw, Value = 20.02 P6 = Top_Jaw, Value = 19.95 21:10:23 Integrated Voltage Measurement... 21:10:45 Voltage Offset Correction: v_off_ini = -0.000001031 V, v_off_fin = 0.000001763 V 21:10:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158469643 Vs 21:10:45 Integrated Voltage Measurement... 21:11:07 Voltage Offset Correction: v_off_ini = 0.000001434 V, v_off_fin = -0.000002034 V 21:11:07 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158497158 Vs 22:07:21 Temperature Measurement, Probe Number = 0, T = 20.178000 C 22:07:22 Temperature Measurement, Probe Number = 1, T = 20.004000 C 22:07:22 Temperature Measurement, Probe Number = 2, T = 20.056000 C 22:07:23 Temperature Measurement, Probe Number = 3, T = 20.036000 C 22:07:23 Temperature Measurement, Probe Number = 4, T = 20.037000 C 22:07:24 Temperature Measurement, Probe Number = 5, T = 19.965000 C 22:07:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.00 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.96 22:07:24 Integrated Voltage Measurement... 22:07:46 Voltage Offset Correction: v_off_ini = -0.000000088 V, v_off_fin = 0.000002663 V 22:07:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.158503801 Vs 22:07:46 Integrated Voltage Measurement... 22:08:08 Voltage Offset Correction: v_off_ini = -0.000002195 V, v_off_fin = -0.000002897 V 22:08:09 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451248 Vs 22:08:22 Temperature Measurement, Probe Number = 0, T = 20.168000 C 22:08:23 Temperature Measurement, Probe Number = 1, T = 20.006000 C 22:08:23 Temperature Measurement, Probe Number = 2, T = 20.060000 C 22:08:24 Temperature Measurement, Probe Number = 3, T = 20.036000 C 22:08:25 Temperature Measurement, Probe Number = 4, T = 20.038000 C 22:08:25 Temperature Measurement, Probe Number = 5, T = 19.966000 C 22:08:25 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:08:25 Integrated Voltage Measurement... 22:08:47 Voltage Offset Correction: v_off_ini = -0.000001032 V, v_off_fin = -0.000000651 V 22:08:47 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158493853 Vs 22:08:47 Integrated Voltage Measurement... 22:09:10 Voltage Offset Correction: v_off_ini = -0.000001170 V, v_off_fin = -0.000002853 V 22:09:10 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158464913 Vs 22:09:23 Temperature Measurement, Probe Number = 0, T = 20.173000 C 22:09:24 Temperature Measurement, Probe Number = 1, T = 20.009000 C 22:09:25 Temperature Measurement, Probe Number = 2, T = 20.063000 C 22:09:25 Temperature Measurement, Probe Number = 3, T = 20.036000 C 22:09:26 Temperature Measurement, Probe Number = 4, T = 20.039000 C 22:09:27 Temperature Measurement, Probe Number = 5, T = 19.968000 C 22:09:27 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:09:27 Integrated Voltage Measurement... 22:09:49 Voltage Offset Correction: v_off_ini = -0.000002795 V, v_off_fin = -0.000000680 V 22:09:49 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158505633 Vs 22:09:49 Integrated Voltage Measurement... 22:10:11 Voltage Offset Correction: v_off_ini = -0.000002429 V, v_off_fin = -0.000003029 V 22:10:11 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158464872 Vs 22:10:25 Temperature Measurement, Probe Number = 0, T = 20.172000 C 22:10:25 Temperature Measurement, Probe Number = 1, T = 20.007000 C 22:10:26 Temperature Measurement, Probe Number = 2, T = 20.063000 C 22:10:27 Temperature Measurement, Probe Number = 3, T = 20.036000 C 22:10:27 Temperature Measurement, Probe Number = 4, T = 20.040000 C 22:10:28 Temperature Measurement, Probe Number = 5, T = 19.967000 C 22:10:28 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:10:28 Integrated Voltage Measurement... 22:10:50 Voltage Offset Correction: v_off_ini = -0.000002605 V, v_off_fin = -0.000003395 V 22:10:50 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158517567 Vs 22:10:50 Integrated Voltage Measurement... 22:11:12 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000002348 V 22:11:12 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158456338 Vs 22:11:26 Temperature Measurement, Probe Number = 0, T = 20.183000 C 22:11:26 Temperature Measurement, Probe Number = 1, T = 20.009000 C 22:11:27 Temperature Measurement, Probe Number = 2, T = 20.064000 C 22:11:28 Temperature Measurement, Probe Number = 3, T = 20.037000 C 22:11:28 Temperature Measurement, Probe Number = 4, T = 20.041000 C 22:11:29 Temperature Measurement, Probe Number = 5, T = 19.969000 C 22:11:29 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.06 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:11:29 Integrated Voltage Measurement... 22:11:51 Voltage Offset Correction: v_off_ini = 0.000000168 V, v_off_fin = -0.000000359 V 22:11:51 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158490809 Vs 22:11:51 Integrated Voltage Measurement... 22:12:13 Voltage Offset Correction: v_off_ini = -0.000000527 V, v_off_fin = -0.000001902 V 22:12:13 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158477738 Vs 22:12:27 Temperature Measurement, Probe Number = 0, T = 20.201000 C 22:12:27 Temperature Measurement, Probe Number = 1, T = 20.011000 C 22:12:28 Temperature Measurement, Probe Number = 2, T = 20.065000 C 22:12:29 Temperature Measurement, Probe Number = 3, T = 20.041000 C 22:12:29 Temperature Measurement, Probe Number = 4, T = 20.042000 C 22:12:30 Temperature Measurement, Probe Number = 5, T = 19.970000 C 22:12:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:12:30 Integrated Voltage Measurement... 22:12:52 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = 0.000000622 V 22:12:52 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158473116 Vs 22:12:52 Integrated Voltage Measurement... 22:13:14 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001873 V 22:13:14 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158473277 Vs 22:13:28 Temperature Measurement, Probe Number = 0, T = 20.235000 C 22:13:29 Temperature Measurement, Probe Number = 1, T = 20.013000 C 22:13:29 Temperature Measurement, Probe Number = 2, T = 20.068000 C 22:13:30 Temperature Measurement, Probe Number = 3, T = 20.042000 C 22:13:30 Temperature Measurement, Probe Number = 4, T = 20.043000 C 22:13:31 Temperature Measurement, Probe Number = 5, T = 19.971000 C 22:13:31 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.23 P2 = Top_US_Module, Value = 20.01 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.04 P6 = Top_Jaw, Value = 19.97 22:13:31 Integrated Voltage Measurement... 22:13:53 Voltage Offset Correction: v_off_ini = 0.000000198 V, v_off_fin = -0.000000732 V 22:13:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158477688 Vs 22:13:53 Integrated Voltage Measurement... 22:14:16 Voltage Offset Correction: v_off_ini = 0.000000029 V, v_off_fin = -0.000003073 V 22:14:16 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158469650 Vs 22:14:30 Temperature Measurement, Probe Number = 0, T = 20.254000 C 22:14:30 Temperature Measurement, Probe Number = 1, T = 20.015000 C 22:14:31 Temperature Measurement, Probe Number = 2, T = 20.071000 C 22:14:32 Temperature Measurement, Probe Number = 3, T = 20.044000 C 22:14:32 Temperature Measurement, Probe Number = 4, T = 20.045000 C 22:14:33 Temperature Measurement, Probe Number = 5, T = 19.974000 C 22:14:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.04 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 19.97 22:14:33 Integrated Voltage Measurement... 22:14:55 Voltage Offset Correction: v_off_ini = -0.000001537 V, v_off_fin = -0.000001793 V 22:14:55 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158501138 Vs 22:14:55 Integrated Voltage Measurement... 22:15:17 Voltage Offset Correction: v_off_ini = 0.000002568 V, v_off_fin = -0.000002466 V 22:15:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158501727 Vs 22:15:31 Temperature Measurement, Probe Number = 0, T = 20.264000 C 22:15:32 Temperature Measurement, Probe Number = 1, T = 20.017000 C 22:15:32 Temperature Measurement, Probe Number = 2, T = 20.072000 C 22:15:33 Temperature Measurement, Probe Number = 3, T = 20.046000 C 22:15:34 Temperature Measurement, Probe Number = 4, T = 20.047000 C 22:15:34 Temperature Measurement, Probe Number = 5, T = 19.975000 C 22:15:34 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 19.98 22:15:34 Integrated Voltage Measurement... 22:15:56 Voltage Offset Correction: v_off_ini = -0.000001127 V, v_off_fin = -0.000001661 V 22:15:56 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158493295 Vs 22:15:56 Integrated Voltage Measurement... 22:16:19 Voltage Offset Correction: v_off_ini = -0.000000080 V, v_off_fin = -0.000001961 V 22:16:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158493517 Vs 22:16:32 Temperature Measurement, Probe Number = 0, T = 20.268000 C 22:16:33 Temperature Measurement, Probe Number = 1, T = 20.017000 C 22:16:33 Temperature Measurement, Probe Number = 2, T = 20.073000 C 22:16:34 Temperature Measurement, Probe Number = 3, T = 20.047000 C 22:16:35 Temperature Measurement, Probe Number = 4, T = 20.046000 C 22:16:35 Temperature Measurement, Probe Number = 5, T = 19.974000 C 22:16:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.02 P3 = Bottom_DS_Module, Value = 20.07 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.05 P6 = Top_Jaw, Value = 19.97 22:16:35 Integrated Voltage Measurement... 22:16:57 Voltage Offset Correction: v_off_ini = -0.000002217 V, v_off_fin = -0.000003629 V 22:16:57 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158497094 Vs 22:16:57 Integrated Voltage Measurement... 22:17:20 Voltage Offset Correction: v_off_ini = -0.000001083 V, v_off_fin = -0.000001471 V 22:17:20 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158471127 Vs 23:13:33 Temperature Measurement, Probe Number = 0, T = 20.318000 C 23:13:34 Temperature Measurement, Probe Number = 1, T = 20.045000 C 23:13:34 Temperature Measurement, Probe Number = 2, T = 20.098000 C 23:13:35 Temperature Measurement, Probe Number = 3, T = 20.078000 C 23:13:36 Temperature Measurement, Probe Number = 4, T = 20.075000 C 23:13:36 Temperature Measurement, Probe Number = 5, T = 20.002000 C 23:13:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.32 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.00 23:13:36 Integrated Voltage Measurement... 23:13:58 Voltage Offset Correction: v_off_ini = 0.000000468 V, v_off_fin = -0.000000710 V 23:13:59 Integrated Voltage Measurement Delta Gap = 0.0040019 m VT = 0.158530721 Vs 23:13:59 Integrated Voltage Measurement... 23:14:21 Voltage Offset Correction: v_off_ini = -0.000001413 V, v_off_fin = -0.000002554 V 23:14:21 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158423987 Vs 23:14:35 Temperature Measurement, Probe Number = 0, T = 20.281000 C 23:14:35 Temperature Measurement, Probe Number = 1, T = 20.045000 C 23:14:36 Temperature Measurement, Probe Number = 2, T = 20.100000 C 23:14:37 Temperature Measurement, Probe Number = 3, T = 20.076000 C 23:14:37 Temperature Measurement, Probe Number = 4, T = 20.075000 C 23:14:38 Temperature Measurement, Probe Number = 5, T = 20.002000 C 23:14:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.28 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.00 23:14:38 Integrated Voltage Measurement... 23:15:00 Voltage Offset Correction: v_off_ini = -0.000002664 V, v_off_fin = -0.000002606 V 23:15:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158495271 Vs 23:15:00 Integrated Voltage Measurement... 23:15:22 Voltage Offset Correction: v_off_ini = -0.000000029 V, v_off_fin = -0.000001969 V 23:15:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158444131 Vs 23:15:36 Temperature Measurement, Probe Number = 0, T = 20.291000 C 23:15:36 Temperature Measurement, Probe Number = 1, T = 20.045000 C 23:15:37 Temperature Measurement, Probe Number = 2, T = 20.100000 C 23:15:38 Temperature Measurement, Probe Number = 3, T = 20.077000 C 23:15:38 Temperature Measurement, Probe Number = 4, T = 20.075000 C 23:15:39 Temperature Measurement, Probe Number = 5, T = 20.002000 C 23:15:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.00 23:15:39 Integrated Voltage Measurement... 23:16:01 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000003616 V 23:16:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158488721 Vs 23:16:01 Integrated Voltage Measurement... 23:16:23 Voltage Offset Correction: v_off_ini = 0.000000527 V, v_off_fin = -0.000002225 V 23:16:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441522 Vs 23:16:37 Temperature Measurement, Probe Number = 0, T = 20.259000 C 23:16:38 Temperature Measurement, Probe Number = 1, T = 20.044000 C 23:16:38 Temperature Measurement, Probe Number = 2, T = 20.097000 C 23:16:39 Temperature Measurement, Probe Number = 3, T = 20.079000 C 23:16:40 Temperature Measurement, Probe Number = 4, T = 20.074000 C 23:16:40 Temperature Measurement, Probe Number = 5, T = 20.001000 C 23:16:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.00 23:16:40 Integrated Voltage Measurement... 23:17:03 Voltage Offset Correction: v_off_ini = -0.000002291 V, v_off_fin = -0.000002079 V 23:17:03 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158489121 Vs 23:17:03 Integrated Voltage Measurement... 23:17:25 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000004479 V 23:17:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158431560 Vs 23:17:39 Temperature Measurement, Probe Number = 0, T = 20.255000 C 23:17:40 Temperature Measurement, Probe Number = 1, T = 20.045000 C 23:17:40 Temperature Measurement, Probe Number = 2, T = 20.099000 C 23:17:41 Temperature Measurement, Probe Number = 3, T = 20.079000 C 23:17:42 Temperature Measurement, Probe Number = 4, T = 20.075000 C 23:17:42 Temperature Measurement, Probe Number = 5, T = 20.002000 C 23:17:42 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.07 P6 = Top_Jaw, Value = 20.00 23:17:42 Integrated Voltage Measurement... 23:18:04 Voltage Offset Correction: v_off_ini = -0.000001215 V, v_off_fin = -0.000002108 V 23:18:04 Integrated Voltage Measurement Delta Gap = 0.0040005 m VT = 0.158461939 Vs 23:18:04 Integrated Voltage Measurement... 23:18:27 Voltage Offset Correction: v_off_ini = -0.000000710 V, v_off_fin = -0.000002752 V 23:18:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435630 Vs 23:18:41 Temperature Measurement, Probe Number = 0, T = 20.292000 C 23:18:41 Temperature Measurement, Probe Number = 1, T = 20.045000 C 23:18:42 Temperature Measurement, Probe Number = 2, T = 20.101000 C 23:18:42 Temperature Measurement, Probe Number = 3, T = 20.079000 C 23:18:43 Temperature Measurement, Probe Number = 4, T = 20.076000 C 23:18:44 Temperature Measurement, Probe Number = 5, T = 20.003000 C 23:18:44 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.29 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.00 23:18:44 Integrated Voltage Measurement... 23:19:06 Voltage Offset Correction: v_off_ini = -0.000003337 V, v_off_fin = -0.000001229 V 23:19:06 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158471912 Vs 23:19:06 Integrated Voltage Measurement... 23:19:28 Voltage Offset Correction: v_off_ini = 0.000001903 V, v_off_fin = -0.000002437 V 23:19:28 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158467862 Vs 23:19:42 Temperature Measurement, Probe Number = 0, T = 20.272000 C 23:19:42 Temperature Measurement, Probe Number = 1, T = 20.047000 C 23:19:43 Temperature Measurement, Probe Number = 2, T = 20.101000 C 23:19:43 Temperature Measurement, Probe Number = 3, T = 20.078000 C 23:19:44 Temperature Measurement, Probe Number = 4, T = 20.077000 C 23:19:45 Temperature Measurement, Probe Number = 5, T = 20.003000 C 23:19:45 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.00 23:19:45 Integrated Voltage Measurement... 23:20:07 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = -0.000000937 V 23:20:08 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158468284 Vs 23:20:08 Integrated Voltage Measurement... 23:20:30 Voltage Offset Correction: v_off_ini = -0.000002518 V, v_off_fin = -0.000000937 V 23:20:30 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158438303 Vs 23:20:43 Temperature Measurement, Probe Number = 0, T = 20.266000 C 23:20:44 Temperature Measurement, Probe Number = 1, T = 20.048000 C 23:20:44 Temperature Measurement, Probe Number = 2, T = 20.103000 C 23:20:45 Temperature Measurement, Probe Number = 3, T = 20.075000 C 23:20:46 Temperature Measurement, Probe Number = 4, T = 20.078000 C 23:20:46 Temperature Measurement, Probe Number = 5, T = 20.004000 C 23:20:46 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.27 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.00 23:20:46 Integrated Voltage Measurement... 23:21:09 Voltage Offset Correction: v_off_ini = -0.000001332 V, v_off_fin = -0.000001003 V 23:21:09 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158479900 Vs 23:21:09 Integrated Voltage Measurement... 23:21:31 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000001413 V 23:21:31 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451653 Vs 23:21:45 Temperature Measurement, Probe Number = 0, T = 20.262000 C 23:21:45 Temperature Measurement, Probe Number = 1, T = 20.047000 C 23:21:46 Temperature Measurement, Probe Number = 2, T = 20.102000 C 23:21:46 Temperature Measurement, Probe Number = 3, T = 20.076000 C 23:21:47 Temperature Measurement, Probe Number = 4, T = 20.078000 C 23:21:48 Temperature Measurement, Probe Number = 5, T = 20.004000 C 23:21:48 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.26 P2 = Top_US_Module, Value = 20.05 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.00 23:21:48 Integrated Voltage Measurement... 23:22:10 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = -0.000003059 V 23:22:10 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158477534 Vs 23:22:10 Integrated Voltage Measurement... 23:22:32 Voltage Offset Correction: v_off_ini = -0.000000732 V, v_off_fin = -0.000001742 V 23:22:32 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439634 Vs 23:22:46 Temperature Measurement, Probe Number = 0, T = 20.246000 C 23:22:46 Temperature Measurement, Probe Number = 1, T = 20.044000 C 23:22:47 Temperature Measurement, Probe Number = 2, T = 20.099000 C 23:22:47 Temperature Measurement, Probe Number = 3, T = 20.078000 C 23:22:48 Temperature Measurement, Probe Number = 4, T = 20.076000 C 23:22:49 Temperature Measurement, Probe Number = 5, T = 20.003000 C 23:22:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.25 P2 = Top_US_Module, Value = 20.04 P3 = Bottom_DS_Module, Value = 20.10 P4 = Encode_Arm, Value = 20.08 P5 = Bottom_Jaw, Value = 20.08 P6 = Top_Jaw, Value = 20.00 23:22:49 Integrated Voltage Measurement... 23:23:11 Voltage Offset Correction: v_off_ini = -0.000000219 V, v_off_fin = -0.000000110 V 23:23:11 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158473453 Vs 23:23:11 Integrated Voltage Measurement... 23:23:33 Voltage Offset Correction: v_off_ini = -0.000002870 V, v_off_fin = -0.000003060 V 23:23:33 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158426113 Vs 00:19:47 Temperature Measurement, Probe Number = 0, T = 20.178000 C 00:19:48 Temperature Measurement, Probe Number = 1, T = 20.057000 C 00:19:48 Temperature Measurement, Probe Number = 2, T = 20.109000 C 00:19:49 Temperature Measurement, Probe Number = 3, T = 20.073000 C 00:19:49 Temperature Measurement, Probe Number = 4, T = 20.088000 C 00:19:50 Temperature Measurement, Probe Number = 5, T = 20.017000 C 00:19:50 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:19:50 Integrated Voltage Measurement... 00:20:12 Voltage Offset Correction: v_off_ini = -0.000000915 V, v_off_fin = 0.000001427 V 00:20:12 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.158489174 Vs 00:20:12 Integrated Voltage Measurement... 00:20:34 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000002546 V 00:20:34 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158450483 Vs 00:20:48 Temperature Measurement, Probe Number = 0, T = 20.188000 C 00:20:49 Temperature Measurement, Probe Number = 1, T = 20.059000 C 00:20:49 Temperature Measurement, Probe Number = 2, T = 20.115000 C 00:20:50 Temperature Measurement, Probe Number = 3, T = 20.073000 C 00:20:50 Temperature Measurement, Probe Number = 4, T = 20.090000 C 00:20:51 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:20:51 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:20:51 Integrated Voltage Measurement... 00:21:13 Voltage Offset Correction: v_off_ini = -0.000002363 V, v_off_fin = -0.000000658 V 00:21:13 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158472700 Vs 00:21:13 Integrated Voltage Measurement... 00:21:35 Voltage Offset Correction: v_off_ini = -0.000000059 V, v_off_fin = -0.000001141 V 00:21:36 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158446917 Vs 00:21:49 Temperature Measurement, Probe Number = 0, T = 20.198000 C 00:21:50 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:21:50 Temperature Measurement, Probe Number = 2, T = 20.114000 C 00:21:51 Temperature Measurement, Probe Number = 3, T = 20.073000 C 00:21:52 Temperature Measurement, Probe Number = 4, T = 20.089000 C 00:21:52 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:21:52 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.20 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:21:52 Integrated Voltage Measurement... 00:22:14 Voltage Offset Correction: v_off_ini = -0.000000066 V, v_off_fin = 0.000000000 V 00:22:14 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158454756 Vs 00:22:14 Integrated Voltage Measurement... 00:22:37 Voltage Offset Correction: v_off_ini = -0.000000000 V, v_off_fin = -0.000002019 V 00:22:37 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448102 Vs 00:22:50 Temperature Measurement, Probe Number = 0, T = 20.187000 C 00:22:51 Temperature Measurement, Probe Number = 1, T = 20.060000 C 00:22:52 Temperature Measurement, Probe Number = 2, T = 20.115000 C 00:22:52 Temperature Measurement, Probe Number = 3, T = 20.072000 C 00:22:53 Temperature Measurement, Probe Number = 4, T = 20.091000 C 00:22:53 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:22:53 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.19 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:22:54 Integrated Voltage Measurement... 00:23:16 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000001741 V 00:23:16 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459362 Vs 00:23:16 Integrated Voltage Measurement... 00:23:39 Voltage Offset Correction: v_off_ini = 0.000000029 V, v_off_fin = -0.000000329 V 00:23:39 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158443031 Vs 00:23:52 Temperature Measurement, Probe Number = 0, T = 20.148000 C 00:23:53 Temperature Measurement, Probe Number = 1, T = 20.061000 C 00:23:53 Temperature Measurement, Probe Number = 2, T = 20.116000 C 00:23:54 Temperature Measurement, Probe Number = 3, T = 20.072000 C 00:23:55 Temperature Measurement, Probe Number = 4, T = 20.092000 C 00:23:55 Temperature Measurement, Probe Number = 5, T = 20.019000 C 00:23:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:23:55 Integrated Voltage Measurement... 00:24:17 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = 0.000000337 V 00:24:17 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158456979 Vs 00:24:17 Integrated Voltage Measurement... 00:24:40 Voltage Offset Correction: v_off_ini = 0.000001661 V, v_off_fin = -0.000002487 V 00:24:40 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158455173 Vs 00:24:54 Temperature Measurement, Probe Number = 0, T = 20.170000 C 00:24:54 Temperature Measurement, Probe Number = 1, T = 20.061000 C 00:24:55 Temperature Measurement, Probe Number = 2, T = 20.116000 C 00:24:55 Temperature Measurement, Probe Number = 3, T = 20.070000 C 00:24:56 Temperature Measurement, Probe Number = 4, T = 20.093000 C 00:24:57 Temperature Measurement, Probe Number = 5, T = 20.020000 C 00:24:57 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:24:57 Integrated Voltage Measurement... 00:25:19 Voltage Offset Correction: v_off_ini = -0.000003373 V, v_off_fin = 0.000000124 V 00:25:19 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158461553 Vs 00:25:19 Integrated Voltage Measurement... 00:25:41 Voltage Offset Correction: v_off_ini = 0.000000615 V, v_off_fin = -0.000001236 V 00:25:41 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158464722 Vs 00:25:55 Temperature Measurement, Probe Number = 0, T = 20.153000 C 00:25:55 Temperature Measurement, Probe Number = 1, T = 20.062000 C 00:25:56 Temperature Measurement, Probe Number = 2, T = 20.115000 C 00:25:56 Temperature Measurement, Probe Number = 3, T = 20.070000 C 00:25:57 Temperature Measurement, Probe Number = 4, T = 20.092000 C 00:25:58 Temperature Measurement, Probe Number = 5, T = 20.019000 C 00:25:58 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:25:58 Integrated Voltage Measurement... 00:26:20 Voltage Offset Correction: v_off_ini = -0.000001405 V, v_off_fin = -0.000000454 V 00:26:20 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158459616 Vs 00:26:20 Integrated Voltage Measurement... 00:26:43 Voltage Offset Correction: v_off_ini = -0.000000585 V, v_off_fin = -0.000000710 V 00:26:43 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158441189 Vs 00:26:56 Temperature Measurement, Probe Number = 0, T = 20.167000 C 00:26:57 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:26:57 Temperature Measurement, Probe Number = 2, T = 20.113000 C 00:26:58 Temperature Measurement, Probe Number = 3, T = 20.072000 C 00:26:59 Temperature Measurement, Probe Number = 4, T = 20.091000 C 00:26:59 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:26:59 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.17 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:26:59 Integrated Voltage Measurement... 00:27:21 Voltage Offset Correction: v_off_ini = -0.000001756 V, v_off_fin = -0.000001683 V 00:27:21 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158482726 Vs 00:27:21 Integrated Voltage Measurement... 00:27:44 Voltage Offset Correction: v_off_ini = -0.000000593 V, v_off_fin = -0.000002737 V 00:27:44 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158448476 Vs 00:27:57 Temperature Measurement, Probe Number = 0, T = 20.180000 C 00:27:58 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:27:59 Temperature Measurement, Probe Number = 2, T = 20.114000 C 00:27:59 Temperature Measurement, Probe Number = 3, T = 20.070000 C 00:28:00 Temperature Measurement, Probe Number = 4, T = 20.089000 C 00:28:00 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:28:00 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.18 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:28:00 Integrated Voltage Measurement... 00:28:23 Voltage Offset Correction: v_off_ini = -0.000000958 V, v_off_fin = -0.000002107 V 00:28:23 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158483351 Vs 00:28:23 Integrated Voltage Measurement... 00:28:45 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000002794 V 00:28:45 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158442784 Vs 00:28:58 Temperature Measurement, Probe Number = 0, T = 20.147000 C 00:28:59 Temperature Measurement, Probe Number = 1, T = 20.059000 C 00:29:00 Temperature Measurement, Probe Number = 2, T = 20.111000 C 00:29:00 Temperature Measurement, Probe Number = 3, T = 20.070000 C 00:29:01 Temperature Measurement, Probe Number = 4, T = 20.090000 C 00:29:01 Temperature Measurement, Probe Number = 5, T = 20.018000 C 00:29:01 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.06 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.02 00:29:01 Integrated Voltage Measurement... 00:29:24 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000000922 V 00:29:24 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158466416 Vs 00:29:24 Integrated Voltage Measurement... 00:29:46 Voltage Offset Correction: v_off_ini = -0.000000973 V, v_off_fin = -0.000001822 V 00:29:46 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158435131 Vs 01:25:59 Temperature Measurement, Probe Number = 0, T = 20.126000 C 01:26:00 Temperature Measurement, Probe Number = 1, T = 20.069000 C 01:26:01 Temperature Measurement, Probe Number = 2, T = 20.117000 C 01:26:01 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:26:02 Temperature Measurement, Probe Number = 4, T = 20.096000 C 01:26:02 Temperature Measurement, Probe Number = 5, T = 20.030000 C 01:26:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:26:02 Integrated Voltage Measurement... 01:26:30 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = -0.000000541 V 01:26:30 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.158485030 Vs 01:26:30 Integrated Voltage Measurement... 01:26:52 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = -0.000001434 V 01:26:52 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158457126 Vs 01:27:06 Temperature Measurement, Probe Number = 0, T = 20.147000 C 01:27:06 Temperature Measurement, Probe Number = 1, T = 20.072000 C 01:27:07 Temperature Measurement, Probe Number = 2, T = 20.121000 C 01:27:07 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:27:08 Temperature Measurement, Probe Number = 4, T = 20.099000 C 01:27:09 Temperature Measurement, Probe Number = 5, T = 20.031000 C 01:27:09 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:27:09 Integrated Voltage Measurement... 01:27:31 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000000263 V 01:27:31 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158453950 Vs 01:27:31 Integrated Voltage Measurement... 01:27:53 Voltage Offset Correction: v_off_ini = -0.000000176 V, v_off_fin = -0.000002261 V 01:27:54 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158446077 Vs 01:28:07 Temperature Measurement, Probe Number = 0, T = 20.157000 C 01:28:08 Temperature Measurement, Probe Number = 1, T = 20.072000 C 01:28:08 Temperature Measurement, Probe Number = 2, T = 20.122000 C 01:28:09 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:28:10 Temperature Measurement, Probe Number = 4, T = 20.099000 C 01:28:10 Temperature Measurement, Probe Number = 5, T = 20.031000 C 01:28:10 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:28:10 Integrated Voltage Measurement... 01:28:32 Voltage Offset Correction: v_off_ini = -0.000002107 V, v_off_fin = -0.000000790 V 01:28:32 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158467510 Vs 01:28:32 Integrated Voltage Measurement... 01:28:55 Voltage Offset Correction: v_off_ini = -0.000000761 V, v_off_fin = -0.000003585 V 01:28:55 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158440174 Vs 01:29:08 Temperature Measurement, Probe Number = 0, T = 20.125000 C 01:29:09 Temperature Measurement, Probe Number = 1, T = 20.070000 C 01:29:10 Temperature Measurement, Probe Number = 2, T = 20.118000 C 01:29:10 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:29:11 Temperature Measurement, Probe Number = 4, T = 20.098000 C 01:29:11 Temperature Measurement, Probe Number = 5, T = 20.030000 C 01:29:11 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.12 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:29:11 Integrated Voltage Measurement... 01:29:34 Voltage Offset Correction: v_off_ini = -0.000001610 V, v_off_fin = -0.000000205 V 01:29:34 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158449552 Vs 01:29:34 Integrated Voltage Measurement... 01:29:56 Voltage Offset Correction: v_off_ini = 0.000000461 V, v_off_fin = -0.000001142 V 01:29:56 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158454489 Vs 01:30:09 Temperature Measurement, Probe Number = 0, T = 20.147000 C 01:30:10 Temperature Measurement, Probe Number = 1, T = 20.069000 C 01:30:11 Temperature Measurement, Probe Number = 2, T = 20.117000 C 01:30:11 Temperature Measurement, Probe Number = 3, T = 20.067000 C 01:30:12 Temperature Measurement, Probe Number = 4, T = 20.098000 C 01:30:12 Temperature Measurement, Probe Number = 5, T = 20.030000 C 01:30:12 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.15 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:30:12 Integrated Voltage Measurement... 01:30:35 Voltage Offset Correction: v_off_ini = -0.000000885 V, v_off_fin = -0.000000761 V 01:30:36 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158462734 Vs 01:30:36 Integrated Voltage Measurement... 01:30:58 Voltage Offset Correction: v_off_ini = -0.000000432 V, v_off_fin = -0.000001756 V 01:30:58 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158428834 Vs 01:31:11 Temperature Measurement, Probe Number = 0, T = 20.136000 C 01:31:12 Temperature Measurement, Probe Number = 1, T = 20.071000 C 01:31:13 Temperature Measurement, Probe Number = 2, T = 20.118000 C 01:31:13 Temperature Measurement, Probe Number = 3, T = 20.069000 C 01:31:14 Temperature Measurement, Probe Number = 4, T = 20.098000 C 01:31:14 Temperature Measurement, Probe Number = 5, T = 20.031000 C 01:31:14 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:31:14 Integrated Voltage Measurement... 01:31:37 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000000293 V 01:31:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158452179 Vs 01:31:37 Integrated Voltage Measurement... 01:32:00 Voltage Offset Correction: v_off_ini = -0.000001676 V, v_off_fin = -0.000001522 V 01:32:00 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158432614 Vs 01:32:13 Temperature Measurement, Probe Number = 0, T = 20.156000 C 01:32:14 Temperature Measurement, Probe Number = 1, T = 20.072000 C 01:32:14 Temperature Measurement, Probe Number = 2, T = 20.119000 C 01:32:15 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:32:16 Temperature Measurement, Probe Number = 4, T = 20.097000 C 01:32:16 Temperature Measurement, Probe Number = 5, T = 20.032000 C 01:32:16 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.16 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:32:16 Integrated Voltage Measurement... 01:32:38 Voltage Offset Correction: v_off_ini = -0.000002934 V, v_off_fin = -0.000000885 V 01:32:38 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158473718 Vs 01:32:38 Integrated Voltage Measurement... 01:33:01 Voltage Offset Correction: v_off_ini = -0.000002926 V, v_off_fin = -0.000002817 V 01:33:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158411578 Vs 01:33:14 Temperature Measurement, Probe Number = 0, T = 20.141000 C 01:33:15 Temperature Measurement, Probe Number = 1, T = 20.069000 C 01:33:16 Temperature Measurement, Probe Number = 2, T = 20.121000 C 01:33:16 Temperature Measurement, Probe Number = 3, T = 20.068000 C 01:33:17 Temperature Measurement, Probe Number = 4, T = 20.098000 C 01:33:17 Temperature Measurement, Probe Number = 5, T = 20.031000 C 01:33:17 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.14 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:33:17 Integrated Voltage Measurement... 01:33:40 Voltage Offset Correction: v_off_ini = -0.000001617 V, v_off_fin = -0.000001097 V 01:33:40 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158456435 Vs 01:33:40 Integrated Voltage Measurement... 01:34:02 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = -0.000002378 V 01:34:02 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158437534 Vs 01:34:15 Temperature Measurement, Probe Number = 0, T = 20.131000 C 01:34:16 Temperature Measurement, Probe Number = 1, T = 20.069000 C 01:34:17 Temperature Measurement, Probe Number = 2, T = 20.117000 C 01:34:17 Temperature Measurement, Probe Number = 3, T = 20.067000 C 01:34:18 Temperature Measurement, Probe Number = 4, T = 20.097000 C 01:34:18 Temperature Measurement, Probe Number = 5, T = 20.030000 C 01:34:18 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.13 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.10 P6 = Top_Jaw, Value = 20.03 01:34:18 Integrated Voltage Measurement... 01:34:41 Voltage Offset Correction: v_off_ini = -0.000001588 V, v_off_fin = 0.000000176 V 01:34:41 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158455732 Vs 01:34:41 Integrated Voltage Measurement... 01:35:03 Voltage Offset Correction: v_off_ini = -0.000003630 V, v_off_fin = -0.000002934 V 01:35:03 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158427885 Vs 01:35:17 Temperature Measurement, Probe Number = 0, T = 20.112000 C 01:35:17 Temperature Measurement, Probe Number = 1, T = 20.069000 C 01:35:18 Temperature Measurement, Probe Number = 2, T = 20.118000 C 01:35:19 Temperature Measurement, Probe Number = 3, T = 20.067000 C 01:35:19 Temperature Measurement, Probe Number = 4, T = 20.095000 C 01:35:20 Temperature Measurement, Probe Number = 5, T = 20.033000 C 01:35:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.11 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.12 P4 = Encode_Arm, Value = 20.07 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 01:35:20 Integrated Voltage Measurement... 01:35:42 Voltage Offset Correction: v_off_ini = -0.000002166 V, v_off_fin = -0.000002693 V 01:35:42 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158490566 Vs 01:35:42 Integrated Voltage Measurement... 01:36:04 Voltage Offset Correction: v_off_ini = -0.000003102 V, v_off_fin = -0.000001639 V 01:36:04 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158424842 Vs 02:32:18 Temperature Measurement, Probe Number = 0, T = 20.090000 C 02:32:18 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:32:19 Temperature Measurement, Probe Number = 2, T = 20.112000 C 02:32:20 Temperature Measurement, Probe Number = 3, T = 20.050000 C 02:32:20 Temperature Measurement, Probe Number = 4, T = 20.093000 C 02:32:21 Temperature Measurement, Probe Number = 5, T = 20.033000 C 02:32:21 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:32:21 Integrated Voltage Measurement... 02:32:43 Voltage Offset Correction: v_off_ini = -0.000001002 V, v_off_fin = -0.000000498 V 02:32:44 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.158486989 Vs 02:32:44 Integrated Voltage Measurement... 02:33:06 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = -0.000002342 V 02:33:06 Integrated Voltage Measurement Delta Gap = -0.0040003 m VT = -0.158435692 Vs 02:33:20 Temperature Measurement, Probe Number = 0, T = 20.089000 C 02:33:20 Temperature Measurement, Probe Number = 1, T = 20.067000 C 02:33:21 Temperature Measurement, Probe Number = 2, T = 20.107000 C 02:33:22 Temperature Measurement, Probe Number = 3, T = 20.050000 C 02:33:22 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:33:23 Temperature Measurement, Probe Number = 5, T = 20.032000 C 02:33:23 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:33:23 Integrated Voltage Measurement... 02:33:45 Voltage Offset Correction: v_off_ini = -0.000001778 V, v_off_fin = -0.000000622 V 02:33:45 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158468697 Vs 02:33:45 Integrated Voltage Measurement... 02:34:07 Voltage Offset Correction: v_off_ini = 0.000001434 V, v_off_fin = -0.000002605 V 02:34:08 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158475383 Vs 02:34:21 Temperature Measurement, Probe Number = 0, T = 20.103000 C 02:34:22 Temperature Measurement, Probe Number = 1, T = 20.070000 C 02:34:22 Temperature Measurement, Probe Number = 2, T = 20.109000 C 02:34:23 Temperature Measurement, Probe Number = 3, T = 20.048000 C 02:34:24 Temperature Measurement, Probe Number = 4, T = 20.091000 C 02:34:24 Temperature Measurement, Probe Number = 5, T = 20.031000 C 02:34:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:34:24 Integrated Voltage Measurement... 02:34:47 Voltage Offset Correction: v_off_ini = -0.000000856 V, v_off_fin = -0.000000680 V 02:34:47 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158464258 Vs 02:34:47 Integrated Voltage Measurement... 02:35:17 Voltage Offset Correction: v_off_ini = -0.000000388 V, v_off_fin = -0.000000790 V 02:35:17 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = -0.158444925 Vs 02:35:30 Temperature Measurement, Probe Number = 0, T = 20.090000 C 02:35:31 Temperature Measurement, Probe Number = 1, T = 20.073000 C 02:35:31 Temperature Measurement, Probe Number = 2, T = 20.111000 C 02:35:32 Temperature Measurement, Probe Number = 3, T = 20.046000 C 02:35:33 Temperature Measurement, Probe Number = 4, T = 20.091000 C 02:35:33 Temperature Measurement, Probe Number = 5, T = 20.033000 C 02:35:33 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:35:33 Integrated Voltage Measurement... 02:35:55 Voltage Offset Correction: v_off_ini = -0.000000900 V, v_off_fin = -0.000001815 V 02:35:55 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = 0.158446773 Vs 02:35:56 Integrated Voltage Measurement... 02:36:18 Voltage Offset Correction: v_off_ini = -0.000001500 V, v_off_fin = -0.000001325 V 02:36:18 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158436631 Vs 02:36:32 Temperature Measurement, Probe Number = 0, T = 20.100000 C 02:36:32 Temperature Measurement, Probe Number = 1, T = 20.070000 C 02:36:33 Temperature Measurement, Probe Number = 2, T = 20.109000 C 02:36:34 Temperature Measurement, Probe Number = 3, T = 20.048000 C 02:36:34 Temperature Measurement, Probe Number = 4, T = 20.090000 C 02:36:35 Temperature Measurement, Probe Number = 5, T = 20.031000 C 02:36:35 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.10 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:36:35 Integrated Voltage Measurement... 02:36:57 Voltage Offset Correction: v_off_ini = -0.000001778 V, v_off_fin = -0.000001024 V 02:36:57 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158471554 Vs 02:36:57 Integrated Voltage Measurement... 02:37:19 Voltage Offset Correction: v_off_ini = -0.000001858 V, v_off_fin = -0.000003131 V 02:37:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158447200 Vs 02:37:33 Temperature Measurement, Probe Number = 0, T = 20.090000 C 02:37:34 Temperature Measurement, Probe Number = 1, T = 20.075000 C 02:37:34 Temperature Measurement, Probe Number = 2, T = 20.112000 C 02:37:35 Temperature Measurement, Probe Number = 3, T = 20.047000 C 02:37:35 Temperature Measurement, Probe Number = 4, T = 20.092000 C 02:37:36 Temperature Measurement, Probe Number = 5, T = 20.033000 C 02:37:36 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:37:36 Integrated Voltage Measurement... 02:37:58 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000003367 V 02:37:58 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = 0.158479243 Vs 02:37:58 Integrated Voltage Measurement... 02:38:21 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = -0.000003337 V 02:38:22 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158446391 Vs 02:38:35 Temperature Measurement, Probe Number = 0, T = 20.088000 C 02:38:36 Temperature Measurement, Probe Number = 1, T = 20.070000 C 02:38:36 Temperature Measurement, Probe Number = 2, T = 20.112000 C 02:38:37 Temperature Measurement, Probe Number = 3, T = 20.048000 C 02:38:38 Temperature Measurement, Probe Number = 4, T = 20.091000 C 02:38:38 Temperature Measurement, Probe Number = 5, T = 20.031000 C 02:38:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:38:38 Integrated Voltage Measurement... 02:39:00 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = -0.000001091 V 02:39:00 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158471850 Vs 02:39:00 Integrated Voltage Measurement... 02:39:22 Voltage Offset Correction: v_off_ini = -0.000002451 V, v_off_fin = -0.000003849 V 02:39:23 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158439518 Vs 02:39:36 Temperature Measurement, Probe Number = 0, T = 20.095000 C 02:39:37 Temperature Measurement, Probe Number = 1, T = 20.071000 C 02:39:37 Temperature Measurement, Probe Number = 2, T = 20.108000 C 02:39:38 Temperature Measurement, Probe Number = 3, T = 20.047000 C 02:39:38 Temperature Measurement, Probe Number = 4, T = 20.090000 C 02:39:39 Temperature Measurement, Probe Number = 5, T = 20.032000 C 02:39:39 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:39:39 Integrated Voltage Measurement... 02:40:01 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000002568 V 02:40:01 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158481093 Vs 02:40:01 Integrated Voltage Measurement... 02:40:24 Voltage Offset Correction: v_off_ini = -0.000002137 V, v_off_fin = -0.000001852 V 02:40:24 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158429239 Vs 02:40:38 Temperature Measurement, Probe Number = 0, T = 20.088000 C 02:40:38 Temperature Measurement, Probe Number = 1, T = 20.072000 C 02:40:39 Temperature Measurement, Probe Number = 2, T = 20.111000 C 02:40:40 Temperature Measurement, Probe Number = 3, T = 20.046000 C 02:40:40 Temperature Measurement, Probe Number = 4, T = 20.090000 C 02:40:41 Temperature Measurement, Probe Number = 5, T = 20.033000 C 02:40:41 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:40:41 Integrated Voltage Measurement... 02:41:03 Voltage Offset Correction: v_off_ini = -0.000002445 V, v_off_fin = -0.000000468 V 02:41:03 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158483302 Vs 02:41:03 Integrated Voltage Measurement... 02:41:26 Voltage Offset Correction: v_off_ini = 0.000000080 V, v_off_fin = -0.000002766 V 02:41:26 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158451216 Vs 02:41:40 Temperature Measurement, Probe Number = 0, T = 20.085000 C 02:41:40 Temperature Measurement, Probe Number = 1, T = 20.069000 C 02:41:41 Temperature Measurement, Probe Number = 2, T = 20.108000 C 02:41:42 Temperature Measurement, Probe Number = 3, T = 20.047000 C 02:41:42 Temperature Measurement, Probe Number = 4, T = 20.089000 C 02:41:43 Temperature Measurement, Probe Number = 5, T = 20.032000 C 02:41:43 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Ambient, Value = 20.09 P2 = Top_US_Module, Value = 20.07 P3 = Bottom_DS_Module, Value = 20.11 P4 = Encode_Arm, Value = 20.05 P5 = Bottom_Jaw, Value = 20.09 P6 = Top_Jaw, Value = 20.03 02:41:43 Integrated Voltage Measurement... 02:42:05 Voltage Offset Correction: v_off_ini = -0.000002371 V, v_off_fin = 0.000000651 V 02:42:05 Integrated Voltage Measurement Delta Gap = 0.0040004 m VT = 0.158462070 Vs 02:42:05 Integrated Voltage Measurement... 02:42:27 Voltage Offset Correction: v_off_ini = 0.000002224 V, v_off_fin = -0.000002378 V 02:42:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = -0.158487516 Vs