SLAC Magnetic Measurements Date: 04-16-2018 Time: 13:18:59 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_PXI_CMM Serial Number: 00 Run Number: 219 Measurement Device: pxi4464 Operator: jeb Comment: After long term meas. After I while, I heated the PXI with a heat gun. 13:18:59 Ambient Measurement Device(s) Being Used, type = None 13:18:59 Magnet Voltage Measurement Device(s) Being Used, type = None 13:19:00 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:19:00 XMAG Device(s) Being Used, type = None 13:19:00 Ambient Measurement Device(s) Being Used, type = None 13:19:03 Temperature Measurement, Probe Number = 0, T = 21.663000 C 13:19:04 Temperature Measurement, Probe Number = 1, T = 20.022000 C 13:19:05 Temperature Measurement, Probe Number = 2, T = 19.997000 C 13:19:05 Temperature Measurement, Probe Number = 3, T = 19.975000 C 13:19:05 Magnet Test Parameter Measurements P0 = Room, Value = 21.66 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:19:06 Integrated Voltage Measurement... 13:19:27 Voltage Offset Correction: v_off_ini = 0.000003229 V, v_off_fin = 0.000005238 V 13:19:27 Integrated Voltage Measurement Delta Gap = 0.0040002 m VT = 0.175343842 Vs 13:19:27 Integrated Voltage Measurement... 13:19:47 Voltage Offset Correction: v_off_ini = 0.000004705 V, v_off_fin = -0.000002513 V 13:19:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175273346 Vs 13:19:49 Temperature Measurement, Probe Number = 0, T = 21.631000 C 13:19:50 Temperature Measurement, Probe Number = 1, T = 20.019000 C 13:19:51 Temperature Measurement, Probe Number = 2, T = 19.996000 C 13:19:51 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:19:51 Magnet Test Parameter Measurements P0 = Room, Value = 21.63 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:19:52 Integrated Voltage Measurement... 13:20:11 Voltage Offset Correction: v_off_ini = 0.000001857 V, v_off_fin = 0.000005476 V 13:20:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175390672 Vs 13:20:11 Integrated Voltage Measurement... 13:20:30 Voltage Offset Correction: v_off_ini = 0.000004540 V, v_off_fin = -0.000002805 V 13:20:30 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175272328 Vs 13:20:33 Temperature Measurement, Probe Number = 0, T = 21.645000 C 13:20:34 Temperature Measurement, Probe Number = 1, T = 20.021000 C 13:20:34 Temperature Measurement, Probe Number = 2, T = 19.995000 C 13:20:35 Temperature Measurement, Probe Number = 3, T = 19.971000 C 13:20:35 Magnet Test Parameter Measurements P0 = Room, Value = 21.64 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:20:35 Integrated Voltage Measurement... 13:20:55 Voltage Offset Correction: v_off_ini = 0.000001067 V, v_off_fin = 0.000005403 V 13:20:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175400511 Vs 13:20:55 Integrated Voltage Measurement... 13:21:14 Voltage Offset Correction: v_off_ini = 0.000004918 V, v_off_fin = -0.000002128 V 13:21:14 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175271183 Vs 13:21:17 Temperature Measurement, Probe Number = 0, T = 21.610000 C 13:21:17 Temperature Measurement, Probe Number = 1, T = 20.018000 C 13:21:18 Temperature Measurement, Probe Number = 2, T = 19.991000 C 13:21:19 Temperature Measurement, Probe Number = 3, T = 19.969000 C 13:21:19 Magnet Test Parameter Measurements P0 = Room, Value = 21.61 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:21:19 Integrated Voltage Measurement... 13:21:38 Voltage Offset Correction: v_off_ini = 0.000001800 V, v_off_fin = 0.000005360 V 13:21:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175397758 Vs 13:21:38 Integrated Voltage Measurement... 13:21:58 Voltage Offset Correction: v_off_ini = 0.000005619 V, v_off_fin = -0.000002484 V 13:21:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175271353 Vs 13:22:01 Temperature Measurement, Probe Number = 0, T = 21.536000 C 13:22:01 Temperature Measurement, Probe Number = 1, T = 20.014000 C 13:22:02 Temperature Measurement, Probe Number = 2, T = 19.988000 C 13:22:03 Temperature Measurement, Probe Number = 3, T = 19.967000 C 13:22:03 Magnet Test Parameter Measurements P0 = Room, Value = 21.54 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:22:03 Integrated Voltage Measurement... 13:22:22 Voltage Offset Correction: v_off_ini = 0.000001209 V, v_off_fin = 0.000005856 V 13:22:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396909 Vs 13:22:22 Integrated Voltage Measurement... 13:22:42 Voltage Offset Correction: v_off_ini = 0.000005902 V, v_off_fin = -0.000001957 V 13:22:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175267728 Vs 13:22:45 Temperature Measurement, Probe Number = 0, T = 21.555000 C 13:22:45 Temperature Measurement, Probe Number = 1, T = 20.015000 C 13:22:46 Temperature Measurement, Probe Number = 2, T = 19.989000 C 13:22:47 Temperature Measurement, Probe Number = 3, T = 19.968000 C 13:22:47 Magnet Test Parameter Measurements P0 = Room, Value = 21.55 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:22:47 Integrated Voltage Measurement... 13:23:06 Voltage Offset Correction: v_off_ini = 0.000000807 V, v_off_fin = 0.000005492 V 13:23:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175392742 Vs 13:23:06 Integrated Voltage Measurement... 13:23:25 Voltage Offset Correction: v_off_ini = 0.000004728 V, v_off_fin = -0.000002726 V 13:23:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175267152 Vs 13:23:28 Temperature Measurement, Probe Number = 0, T = 21.637000 C 13:23:29 Temperature Measurement, Probe Number = 1, T = 20.018000 C 13:23:29 Temperature Measurement, Probe Number = 2, T = 19.990000 C 13:23:30 Temperature Measurement, Probe Number = 3, T = 19.967000 C 13:23:30 Magnet Test Parameter Measurements P0 = Room, Value = 21.64 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:23:30 Integrated Voltage Measurement... 13:23:49 Voltage Offset Correction: v_off_ini = 0.000002117 V, v_off_fin = 0.000005593 V 13:23:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175404140 Vs 13:23:50 Integrated Voltage Measurement... 13:24:09 Voltage Offset Correction: v_off_ini = 0.000005196 V, v_off_fin = -0.000002126 V 13:24:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175268622 Vs 13:24:12 Temperature Measurement, Probe Number = 0, T = 21.778000 C 13:24:12 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:24:13 Temperature Measurement, Probe Number = 2, T = 19.994000 C 13:24:14 Temperature Measurement, Probe Number = 3, T = 19.969000 C 13:24:14 Magnet Test Parameter Measurements P0 = Room, Value = 21.78 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:24:14 Integrated Voltage Measurement... 13:24:33 Voltage Offset Correction: v_off_ini = 0.000001081 V, v_off_fin = 0.000005517 V 13:24:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175390426 Vs 13:24:34 Integrated Voltage Measurement... 13:24:54 Voltage Offset Correction: v_off_ini = 0.000005190 V, v_off_fin = -0.000001824 V 13:24:54 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175278735 Vs 13:24:57 Temperature Measurement, Probe Number = 0, T = 21.800000 C 13:24:57 Temperature Measurement, Probe Number = 1, T = 20.022000 C 13:24:58 Temperature Measurement, Probe Number = 2, T = 19.994000 C 13:24:59 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:24:59 Magnet Test Parameter Measurements P0 = Room, Value = 21.80 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:24:59 Integrated Voltage Measurement... 13:25:18 Voltage Offset Correction: v_off_ini = 0.000001137 V, v_off_fin = 0.000005455 V 13:25:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175379180 Vs 13:25:18 Integrated Voltage Measurement... 13:25:39 Voltage Offset Correction: v_off_ini = 0.000004991 V, v_off_fin = -0.000001484 V 13:25:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175270744 Vs 13:25:42 Temperature Measurement, Probe Number = 0, T = 21.797000 C 13:25:42 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:25:43 Temperature Measurement, Probe Number = 2, T = 19.993000 C 13:25:44 Temperature Measurement, Probe Number = 3, T = 19.969000 C 13:25:44 Magnet Test Parameter Measurements P0 = Room, Value = 21.80 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:25:44 Integrated Voltage Measurement... 13:26:03 Voltage Offset Correction: v_off_ini = 0.000001348 V, v_off_fin = 0.000004945 V 13:26:03 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175368538 Vs 13:26:03 Integrated Voltage Measurement... 13:26:22 Voltage Offset Correction: v_off_ini = 0.000004043 V, v_off_fin = -0.000003089 V 13:26:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175275733 Vs 13:27:25 Temperature Measurement, Probe Number = 0, T = 21.706000 C 13:27:26 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:27:27 Temperature Measurement, Probe Number = 2, T = 19.992000 C 13:27:27 Temperature Measurement, Probe Number = 3, T = 19.967000 C 13:27:27 Magnet Test Parameter Measurements P0 = Room, Value = 21.71 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:27:27 Integrated Voltage Measurement... 13:27:46 Voltage Offset Correction: v_off_ini = 0.000003263 V, v_off_fin = 0.000005061 V 13:27:47 Integrated Voltage Measurement Delta Gap = 0.0040023 m VT = 0.175424021 Vs 13:27:47 Integrated Voltage Measurement... 13:28:06 Voltage Offset Correction: v_off_ini = 0.000004554 V, v_off_fin = -0.000003431 V 13:28:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175280504 Vs 13:28:09 Temperature Measurement, Probe Number = 0, T = 21.775000 C 13:28:10 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:28:11 Temperature Measurement, Probe Number = 2, T = 19.989000 C 13:28:11 Temperature Measurement, Probe Number = 3, T = 19.964000 C 13:28:11 Magnet Test Parameter Measurements P0 = Room, Value = 21.77 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 13:28:11 Integrated Voltage Measurement... 13:28:30 Voltage Offset Correction: v_off_ini = 0.000001227 V, v_off_fin = 0.000005329 V 13:28:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175378400 Vs 13:28:31 Integrated Voltage Measurement... 13:28:50 Voltage Offset Correction: v_off_ini = 0.000004287 V, v_off_fin = -0.000002335 V 13:28:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175270141 Vs 13:28:53 Temperature Measurement, Probe Number = 0, T = 21.673000 C 13:28:53 Temperature Measurement, Probe Number = 1, T = 20.015000 C 13:28:54 Temperature Measurement, Probe Number = 2, T = 19.987000 C 13:28:55 Temperature Measurement, Probe Number = 3, T = 19.965000 C 13:28:55 Magnet Test Parameter Measurements P0 = Room, Value = 21.67 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 13:28:55 Integrated Voltage Measurement... 13:29:15 Voltage Offset Correction: v_off_ini = 0.000001123 V, v_off_fin = 0.000004653 V 13:29:15 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175381156 Vs 13:29:15 Integrated Voltage Measurement... 13:29:34 Voltage Offset Correction: v_off_ini = 0.000003635 V, v_off_fin = -0.000002616 V 13:29:34 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175280218 Vs 13:29:37 Temperature Measurement, Probe Number = 0, T = 21.583000 C 13:29:38 Temperature Measurement, Probe Number = 1, T = 20.013000 C 13:29:38 Temperature Measurement, Probe Number = 2, T = 19.985000 C 13:29:39 Temperature Measurement, Probe Number = 3, T = 19.963000 C 13:29:39 Magnet Test Parameter Measurements P0 = Room, Value = 21.58 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 13:29:39 Integrated Voltage Measurement... 13:29:58 Voltage Offset Correction: v_off_ini = 0.000000879 V, v_off_fin = 0.000005186 V 13:29:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175381813 Vs 13:29:59 Integrated Voltage Measurement... 13:30:18 Voltage Offset Correction: v_off_ini = 0.000004671 V, v_off_fin = -0.000003312 V 13:30:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175271180 Vs 13:30:21 Temperature Measurement, Probe Number = 0, T = 21.535000 C 13:30:21 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:30:22 Temperature Measurement, Probe Number = 2, T = 19.992000 C 13:30:23 Temperature Measurement, Probe Number = 3, T = 19.973000 C 13:30:23 Magnet Test Parameter Measurements P0 = Room, Value = 21.54 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:30:23 Integrated Voltage Measurement... 13:30:42 Voltage Offset Correction: v_off_ini = 0.000000732 V, v_off_fin = 0.000004667 V 13:30:42 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175378549 Vs 13:30:42 Integrated Voltage Measurement... 13:31:01 Voltage Offset Correction: v_off_ini = 0.000003819 V, v_off_fin = -0.000003912 V 13:31:01 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175275859 Vs 13:31:04 Temperature Measurement, Probe Number = 0, T = 21.555000 C 13:31:04 Temperature Measurement, Probe Number = 1, T = 20.018000 C 13:31:05 Temperature Measurement, Probe Number = 2, T = 19.989000 C 13:31:06 Temperature Measurement, Probe Number = 3, T = 19.970000 C 13:31:06 Magnet Test Parameter Measurements P0 = Room, Value = 21.55 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:31:06 Integrated Voltage Measurement... 13:31:25 Voltage Offset Correction: v_off_ini = 0.000000843 V, v_off_fin = 0.000005510 V 13:31:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175378312 Vs 13:31:26 Integrated Voltage Measurement... 13:31:45 Voltage Offset Correction: v_off_ini = 0.000004483 V, v_off_fin = -0.000002459 V 13:31:45 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175277298 Vs 13:31:48 Temperature Measurement, Probe Number = 0, T = 21.556000 C 13:31:49 Temperature Measurement, Probe Number = 1, T = 20.012000 C 13:31:49 Temperature Measurement, Probe Number = 2, T = 19.983000 C 13:31:50 Temperature Measurement, Probe Number = 3, T = 19.963000 C 13:31:50 Magnet Test Parameter Measurements P0 = Room, Value = 21.56 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 13:31:50 Integrated Voltage Measurement... 13:32:10 Voltage Offset Correction: v_off_ini = 0.000000082 V, v_off_fin = 0.000005705 V 13:32:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175381209 Vs 13:32:10 Integrated Voltage Measurement... 13:32:29 Voltage Offset Correction: v_off_ini = 0.000004497 V, v_off_fin = -0.000002064 V 13:32:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175264601 Vs 13:32:32 Temperature Measurement, Probe Number = 0, T = 21.540000 C 13:32:33 Temperature Measurement, Probe Number = 1, T = 20.014000 C 13:32:34 Temperature Measurement, Probe Number = 2, T = 19.986000 C 13:32:34 Temperature Measurement, Probe Number = 3, T = 19.962000 C 13:32:34 Magnet Test Parameter Measurements P0 = Room, Value = 21.54 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 13:32:35 Integrated Voltage Measurement... 13:32:54 Voltage Offset Correction: v_off_ini = 0.000001876 V, v_off_fin = 0.000005404 V 13:32:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175387968 Vs 13:32:54 Integrated Voltage Measurement... 13:33:13 Voltage Offset Correction: v_off_ini = 0.000004500 V, v_off_fin = -0.000003099 V 13:33:13 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175265141 Vs 13:33:16 Temperature Measurement, Probe Number = 0, T = 21.569000 C 13:33:17 Temperature Measurement, Probe Number = 1, T = 20.014000 C 13:33:17 Temperature Measurement, Probe Number = 2, T = 19.985000 C 13:33:18 Temperature Measurement, Probe Number = 3, T = 19.962000 C 13:33:18 Magnet Test Parameter Measurements P0 = Room, Value = 21.57 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 13:33:18 Integrated Voltage Measurement... 13:33:37 Voltage Offset Correction: v_off_ini = 0.000000674 V, v_off_fin = 0.000005276 V 13:33:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175373570 Vs 13:33:37 Integrated Voltage Measurement... 13:33:57 Voltage Offset Correction: v_off_ini = 0.000004587 V, v_off_fin = -0.000002196 V 13:33:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175272371 Vs 13:34:00 Temperature Measurement, Probe Number = 0, T = 21.562000 C 13:34:00 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:34:01 Temperature Measurement, Probe Number = 2, T = 19.988000 C 13:34:02 Temperature Measurement, Probe Number = 3, T = 19.965000 C 13:34:02 Magnet Test Parameter Measurements P0 = Room, Value = 21.56 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 13:34:02 Integrated Voltage Measurement... 13:34:21 Voltage Offset Correction: v_off_ini = 0.000001100 V, v_off_fin = 0.000005047 V 13:34:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175371082 Vs 13:34:21 Integrated Voltage Measurement... 13:34:41 Voltage Offset Correction: v_off_ini = 0.000004429 V, v_off_fin = -0.000001712 V 13:34:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175264220 Vs 13:35:44 Temperature Measurement, Probe Number = 0, T = 21.731000 C 13:35:45 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:35:46 Temperature Measurement, Probe Number = 2, T = 19.988000 C 13:35:46 Temperature Measurement, Probe Number = 3, T = 19.968000 C 13:35:46 Magnet Test Parameter Measurements P0 = Room, Value = 21.73 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:35:46 Integrated Voltage Measurement... 13:36:06 Voltage Offset Correction: v_off_ini = 0.000002962 V, v_off_fin = 0.000005018 V 13:36:06 Integrated Voltage Measurement Delta Gap = 0.0040021 m VT = 0.175405381 Vs 13:36:06 Integrated Voltage Measurement... 13:36:27 Voltage Offset Correction: v_off_ini = 0.000004319 V, v_off_fin = -0.000000796 V 13:36:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175267162 Vs 13:36:29 Temperature Measurement, Probe Number = 0, T = 21.677000 C 13:36:30 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:36:31 Temperature Measurement, Probe Number = 2, T = 19.987000 C 13:36:31 Temperature Measurement, Probe Number = 3, T = 19.966000 C 13:36:32 Magnet Test Parameter Measurements P0 = Room, Value = 21.68 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:36:32 Integrated Voltage Measurement... 13:36:51 Voltage Offset Correction: v_off_ini = 0.000001570 V, v_off_fin = 0.000005123 V 13:36:51 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175360744 Vs 13:36:51 Integrated Voltage Measurement... 13:37:10 Voltage Offset Correction: v_off_ini = 0.000004080 V, v_off_fin = -0.000002584 V 13:37:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175264973 Vs 13:37:13 Temperature Measurement, Probe Number = 0, T = 21.807000 C 13:37:14 Temperature Measurement, Probe Number = 1, T = 20.017000 C 13:37:15 Temperature Measurement, Probe Number = 2, T = 19.985000 C 13:37:15 Temperature Measurement, Probe Number = 3, T = 19.967000 C 13:37:15 Magnet Test Parameter Measurements P0 = Room, Value = 21.81 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 13:37:15 Integrated Voltage Measurement... 13:37:34 Voltage Offset Correction: v_off_ini = 0.000000974 V, v_off_fin = 0.000005023 V 13:37:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175373685 Vs 13:37:35 Integrated Voltage Measurement... 13:37:54 Voltage Offset Correction: v_off_ini = 0.000004396 V, v_off_fin = -0.000002962 V 13:37:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175269659 Vs 13:37:57 Temperature Measurement, Probe Number = 0, T = 21.861000 C 13:37:58 Temperature Measurement, Probe Number = 1, T = 20.015000 C 13:37:58 Temperature Measurement, Probe Number = 2, T = 19.987000 C 13:37:59 Temperature Measurement, Probe Number = 3, T = 19.966000 C 13:37:59 Magnet Test Parameter Measurements P0 = Room, Value = 21.86 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:37:59 Integrated Voltage Measurement... 13:38:18 Voltage Offset Correction: v_off_ini = 0.000001328 V, v_off_fin = 0.000005699 V 13:38:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175373254 Vs 13:38:19 Integrated Voltage Measurement... 13:38:38 Voltage Offset Correction: v_off_ini = 0.000004650 V, v_off_fin = -0.000002588 V 13:38:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175268596 Vs 13:38:41 Temperature Measurement, Probe Number = 0, T = 21.909000 C 13:38:42 Temperature Measurement, Probe Number = 1, T = 20.018000 C 13:38:42 Temperature Measurement, Probe Number = 2, T = 19.988000 C 13:38:43 Temperature Measurement, Probe Number = 3, T = 19.968000 C 13:38:43 Magnet Test Parameter Measurements P0 = Room, Value = 21.91 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:38:43 Integrated Voltage Measurement... 13:39:03 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000004943 V 13:39:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175372089 Vs 13:39:03 Integrated Voltage Measurement... 13:39:22 Voltage Offset Correction: v_off_ini = 0.000003682 V, v_off_fin = -0.000002983 V 13:39:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175270573 Vs 13:39:25 Temperature Measurement, Probe Number = 0, T = 21.897000 C 13:39:26 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:39:26 Temperature Measurement, Probe Number = 2, T = 19.993000 C 13:39:27 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:39:27 Magnet Test Parameter Measurements P0 = Room, Value = 21.90 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:39:27 Integrated Voltage Measurement... 13:39:47 Voltage Offset Correction: v_off_ini = -0.000000358 V, v_off_fin = 0.000004877 V 13:39:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175365616 Vs 13:39:48 Integrated Voltage Measurement... 13:40:07 Voltage Offset Correction: v_off_ini = 0.000003615 V, v_off_fin = -0.000002978 V 13:40:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175266594 Vs 13:40:10 Temperature Measurement, Probe Number = 0, T = 21.767000 C 13:40:10 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:40:11 Temperature Measurement, Probe Number = 2, T = 19.991000 C 13:40:12 Temperature Measurement, Probe Number = 3, T = 19.970000 C 13:40:12 Magnet Test Parameter Measurements P0 = Room, Value = 21.77 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:40:12 Integrated Voltage Measurement... 13:40:31 Voltage Offset Correction: v_off_ini = 0.000000587 V, v_off_fin = 0.000005239 V 13:40:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175375863 Vs 13:40:31 Integrated Voltage Measurement... 13:40:50 Voltage Offset Correction: v_off_ini = 0.000004082 V, v_off_fin = -0.000001890 V 13:40:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175262915 Vs 13:40:53 Temperature Measurement, Probe Number = 0, T = 21.689000 C 13:40:54 Temperature Measurement, Probe Number = 1, T = 20.020000 C 13:40:55 Temperature Measurement, Probe Number = 2, T = 19.993000 C 13:40:55 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:40:55 Magnet Test Parameter Measurements P0 = Room, Value = 21.69 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:40:55 Integrated Voltage Measurement... 13:41:15 Voltage Offset Correction: v_off_ini = 0.000001267 V, v_off_fin = 0.000005084 V 13:41:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175374588 Vs 13:41:16 Integrated Voltage Measurement... 13:41:35 Voltage Offset Correction: v_off_ini = 0.000004894 V, v_off_fin = -0.000002974 V 13:41:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175262359 Vs 13:41:38 Temperature Measurement, Probe Number = 0, T = 21.766000 C 13:41:38 Temperature Measurement, Probe Number = 1, T = 20.022000 C 13:41:39 Temperature Measurement, Probe Number = 2, T = 19.995000 C 13:41:40 Temperature Measurement, Probe Number = 3, T = 19.975000 C 13:41:40 Magnet Test Parameter Measurements P0 = Room, Value = 21.77 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:41:40 Integrated Voltage Measurement... 13:41:59 Voltage Offset Correction: v_off_ini = 0.000000596 V, v_off_fin = 0.000005110 V 13:41:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175376361 Vs 13:41:59 Integrated Voltage Measurement... 13:42:19 Voltage Offset Correction: v_off_ini = 0.000004668 V, v_off_fin = -0.000002655 V 13:42:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175260449 Vs 13:42:22 Temperature Measurement, Probe Number = 0, T = 21.815000 C 13:42:22 Temperature Measurement, Probe Number = 1, T = 20.026000 C 13:42:23 Temperature Measurement, Probe Number = 2, T = 19.998000 C 13:42:24 Temperature Measurement, Probe Number = 3, T = 19.978000 C 13:42:24 Magnet Test Parameter Measurements P0 = Room, Value = 21.82 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:42:24 Integrated Voltage Measurement... 13:42:43 Voltage Offset Correction: v_off_ini = 0.000001064 V, v_off_fin = 0.000005040 V 13:42:43 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175361939 Vs 13:42:43 Integrated Voltage Measurement... 13:43:03 Voltage Offset Correction: v_off_ini = 0.000004095 V, v_off_fin = -0.000002194 V 13:43:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175267604 Vs 13:44:06 Temperature Measurement, Probe Number = 0, T = 27.471000 C 13:44:06 Temperature Measurement, Probe Number = 1, T = 20.021000 C 13:44:07 Temperature Measurement, Probe Number = 2, T = 19.991000 C 13:44:08 Temperature Measurement, Probe Number = 3, T = 19.969000 C 13:44:08 Magnet Test Parameter Measurements P0 = Room, Value = 27.47 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:44:08 Integrated Voltage Measurement... 13:44:27 Voltage Offset Correction: v_off_ini = 0.000004226 V, v_off_fin = 0.000009416 V 13:44:27 Integrated Voltage Measurement Delta Gap = 0.0040023 m VT = 0.175438378 Vs 13:44:28 Integrated Voltage Measurement... 13:44:47 Voltage Offset Correction: v_off_ini = 0.000008558 V, v_off_fin = -0.000002507 V 13:44:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175235246 Vs 13:44:50 Temperature Measurement, Probe Number = 0, T = 27.113000 C 13:44:50 Temperature Measurement, Probe Number = 1, T = 20.019000 C 13:44:51 Temperature Measurement, Probe Number = 2, T = 19.992000 C 13:44:52 Temperature Measurement, Probe Number = 3, T = 19.971000 C 13:44:52 Magnet Test Parameter Measurements P0 = Room, Value = 27.11 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 13:44:52 Integrated Voltage Measurement... 13:45:11 Voltage Offset Correction: v_off_ini = -0.000000439 V, v_off_fin = 0.000004333 V 13:45:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175354490 Vs 13:45:11 Integrated Voltage Measurement... 13:45:30 Voltage Offset Correction: v_off_ini = 0.000003582 V, v_off_fin = -0.000003177 V 13:45:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175265949 Vs 13:45:33 Temperature Measurement, Probe Number = 0, T = 27.223000 C 13:45:34 Temperature Measurement, Probe Number = 1, T = 20.025000 C 13:45:35 Temperature Measurement, Probe Number = 2, T = 19.999000 C 13:45:35 Temperature Measurement, Probe Number = 3, T = 19.974000 C 13:45:35 Magnet Test Parameter Measurements P0 = Room, Value = 27.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:45:35 Integrated Voltage Measurement... 13:45:55 Voltage Offset Correction: v_off_ini = 0.000000273 V, v_off_fin = 0.000004002 V 13:45:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175366936 Vs 13:45:55 Integrated Voltage Measurement... 13:46:14 Voltage Offset Correction: v_off_ini = 0.000003024 V, v_off_fin = -0.000005016 V 13:46:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279175 Vs 13:46:17 Temperature Measurement, Probe Number = 0, T = 27.118000 C 13:46:18 Temperature Measurement, Probe Number = 1, T = 20.027000 C 13:46:18 Temperature Measurement, Probe Number = 2, T = 19.999000 C 13:46:19 Temperature Measurement, Probe Number = 3, T = 19.973000 C 13:46:19 Magnet Test Parameter Measurements P0 = Room, Value = 27.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:46:19 Integrated Voltage Measurement... 13:46:38 Voltage Offset Correction: v_off_ini = -0.000002616 V, v_off_fin = 0.000004109 V 13:46:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175353568 Vs 13:46:39 Integrated Voltage Measurement... 13:46:58 Voltage Offset Correction: v_off_ini = 0.000003368 V, v_off_fin = -0.000001074 V 13:46:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175250166 Vs 13:47:01 Temperature Measurement, Probe Number = 0, T = 26.770000 C 13:47:01 Temperature Measurement, Probe Number = 1, T = 20.027000 C 13:47:02 Temperature Measurement, Probe Number = 2, T = 20.003000 C 13:47:03 Temperature Measurement, Probe Number = 3, T = 19.976000 C 13:47:03 Magnet Test Parameter Measurements P0 = Room, Value = 26.77 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:47:03 Integrated Voltage Measurement... 13:47:22 Voltage Offset Correction: v_off_ini = 0.000001402 V, v_off_fin = 0.000004106 V 13:47:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175366176 Vs 13:47:22 Integrated Voltage Measurement... 13:47:43 Voltage Offset Correction: v_off_ini = 0.000003068 V, v_off_fin = -0.000002749 V 13:47:43 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175271660 Vs 13:47:46 Temperature Measurement, Probe Number = 0, T = 25.362000 C 13:47:46 Temperature Measurement, Probe Number = 1, T = 20.025000 C 13:47:47 Temperature Measurement, Probe Number = 2, T = 19.999000 C 13:47:48 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:47:48 Magnet Test Parameter Measurements P0 = Room, Value = 25.36 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:47:48 Integrated Voltage Measurement... 13:48:07 Voltage Offset Correction: v_off_ini = -0.000000838 V, v_off_fin = 0.000002892 V 13:48:08 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175328086 Vs 13:48:08 Integrated Voltage Measurement... 13:48:27 Voltage Offset Correction: v_off_ini = 0.000002894 V, v_off_fin = -0.000003143 V 13:48:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175276803 Vs 13:48:30 Temperature Measurement, Probe Number = 0, T = 25.484000 C 13:48:31 Temperature Measurement, Probe Number = 1, T = 20.025000 C 13:48:31 Temperature Measurement, Probe Number = 2, T = 19.999000 C 13:48:32 Temperature Measurement, Probe Number = 3, T = 19.974000 C 13:48:32 Magnet Test Parameter Measurements P0 = Room, Value = 25.48 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:48:32 Integrated Voltage Measurement... 13:48:51 Voltage Offset Correction: v_off_ini = -0.000000840 V, v_off_fin = 0.000002865 V 13:48:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175339545 Vs 13:48:52 Integrated Voltage Measurement... 13:49:11 Voltage Offset Correction: v_off_ini = 0.000002810 V, v_off_fin = -0.000005199 V 13:49:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175271948 Vs 13:49:13 Temperature Measurement, Probe Number = 0, T = 24.555000 C 13:49:14 Temperature Measurement, Probe Number = 1, T = 20.025000 C 13:49:15 Temperature Measurement, Probe Number = 2, T = 19.996000 C 13:49:15 Temperature Measurement, Probe Number = 3, T = 19.972000 C 13:49:15 Magnet Test Parameter Measurements P0 = Room, Value = 24.55 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 13:49:16 Integrated Voltage Measurement... 13:49:35 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = 0.000003553 V 13:49:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175339185 Vs 13:49:35 Integrated Voltage Measurement... 13:49:54 Voltage Offset Correction: v_off_ini = 0.000002494 V, v_off_fin = -0.000003986 V 13:49:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175275862 Vs 13:49:57 Temperature Measurement, Probe Number = 0, T = 23.792000 C 13:49:58 Temperature Measurement, Probe Number = 1, T = 20.026000 C 13:49:58 Temperature Measurement, Probe Number = 2, T = 20.002000 C 13:49:59 Temperature Measurement, Probe Number = 3, T = 19.975000 C 13:49:59 Magnet Test Parameter Measurements P0 = Room, Value = 23.79 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:49:59 Integrated Voltage Measurement... 13:50:19 Voltage Offset Correction: v_off_ini = -0.000000610 V, v_off_fin = 0.000003529 V 13:50:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175343405 Vs 13:50:19 Integrated Voltage Measurement... 13:50:38 Voltage Offset Correction: v_off_ini = 0.000002188 V, v_off_fin = -0.000004826 V 13:50:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285633 Vs 13:50:41 Temperature Measurement, Probe Number = 0, T = 23.207000 C 13:50:42 Temperature Measurement, Probe Number = 1, T = 20.028000 C 13:50:42 Temperature Measurement, Probe Number = 2, T = 20.004000 C 13:50:43 Temperature Measurement, Probe Number = 3, T = 19.979000 C 13:50:43 Magnet Test Parameter Measurements P0 = Room, Value = 23.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 13:50:43 Integrated Voltage Measurement... 13:51:02 Voltage Offset Correction: v_off_ini = -0.000000503 V, v_off_fin = 0.000003315 V 13:51:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175347317 Vs 13:51:03 Integrated Voltage Measurement... 13:51:22 Voltage Offset Correction: v_off_ini = 0.000002728 V, v_off_fin = -0.000003930 V 13:51:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175267178 Vs