SLAC Magnetic Measurements Date: 04-10-2018 Time: 15:33:26 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_PXI_CMM Serial Number: 00 Run Number: 218 Measurement Device: pxi4464 Operator: jeb Comment: Long term measurements w/ the PXI4464 15:33:26 Ambient Measurement Device(s) Being Used, type = None 15:33:26 Magnet Voltage Measurement Device(s) Being Used, type = None 15:33:27 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:33:27 XMAG Device(s) Being Used, type = None 15:33:27 Ambient Measurement Device(s) Being Used, type = None 15:33:29 Temperature Measurement, Probe Number = 0, T = 20.509000 C 15:33:30 Temperature Measurement, Probe Number = 1, T = 20.117000 C 15:33:31 Temperature Measurement, Probe Number = 2, T = 20.090000 C 15:33:32 Temperature Measurement, Probe Number = 3, T = 20.053000 C 15:33:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:33:32 Integrated Voltage Measurement... 15:33:52 Voltage Offset Correction: v_off_ini = 0.000004543 V, v_off_fin = 0.000005846 V 15:33:53 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175420833 Vs 15:33:53 Integrated Voltage Measurement... 15:34:12 Voltage Offset Correction: v_off_ini = 0.000004981 V, v_off_fin = -0.000001215 V 15:34:12 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310091 Vs 15:34:15 Temperature Measurement, Probe Number = 0, T = 20.491000 C 15:34:15 Temperature Measurement, Probe Number = 1, T = 20.115000 C 15:34:16 Temperature Measurement, Probe Number = 2, T = 20.087000 C 15:34:17 Temperature Measurement, Probe Number = 3, T = 20.051000 C 15:34:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:34:17 Integrated Voltage Measurement... 15:34:36 Voltage Offset Correction: v_off_ini = 0.000001431 V, v_off_fin = 0.000006134 V 15:34:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175434047 Vs 15:34:36 Integrated Voltage Measurement... 15:34:55 Voltage Offset Correction: v_off_ini = 0.000005322 V, v_off_fin = -0.000001888 V 15:34:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175308677 Vs 15:34:58 Temperature Measurement, Probe Number = 0, T = 20.533000 C 15:34:59 Temperature Measurement, Probe Number = 1, T = 20.118000 C 15:35:00 Temperature Measurement, Probe Number = 2, T = 20.087000 C 15:35:00 Temperature Measurement, Probe Number = 3, T = 20.050000 C 15:35:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.53 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:35:01 Integrated Voltage Measurement... 15:35:20 Voltage Offset Correction: v_off_ini = 0.000002251 V, v_off_fin = 0.000006768 V 15:35:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175439561 Vs 15:35:20 Integrated Voltage Measurement... 15:35:39 Voltage Offset Correction: v_off_ini = 0.000005815 V, v_off_fin = -0.000000592 V 15:35:39 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175302800 Vs 15:35:42 Temperature Measurement, Probe Number = 0, T = 20.536000 C 15:35:43 Temperature Measurement, Probe Number = 1, T = 20.120000 C 15:35:43 Temperature Measurement, Probe Number = 2, T = 20.089000 C 15:35:44 Temperature Measurement, Probe Number = 3, T = 20.051000 C 15:35:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.54 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:35:44 Integrated Voltage Measurement... 15:36:03 Voltage Offset Correction: v_off_ini = 0.000001697 V, v_off_fin = 0.000006870 V 15:36:03 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175444518 Vs 15:36:03 Integrated Voltage Measurement... 15:36:23 Voltage Offset Correction: v_off_ini = 0.000006379 V, v_off_fin = -0.000000402 V 15:36:23 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175299405 Vs 15:36:26 Temperature Measurement, Probe Number = 0, T = 20.514000 C 15:36:26 Temperature Measurement, Probe Number = 1, T = 20.119000 C 15:36:27 Temperature Measurement, Probe Number = 2, T = 20.088000 C 15:36:27 Temperature Measurement, Probe Number = 3, T = 20.051000 C 15:36:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:36:28 Integrated Voltage Measurement... 15:36:47 Voltage Offset Correction: v_off_ini = 0.000002846 V, v_off_fin = 0.000007041 V 15:36:47 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175445980 Vs 15:36:47 Integrated Voltage Measurement... 15:37:07 Voltage Offset Correction: v_off_ini = 0.000006267 V, v_off_fin = -0.000001025 V 15:37:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175310175 Vs 15:37:10 Temperature Measurement, Probe Number = 0, T = 20.507000 C 15:37:10 Temperature Measurement, Probe Number = 1, T = 20.116000 C 15:37:11 Temperature Measurement, Probe Number = 2, T = 20.085000 C 15:37:12 Temperature Measurement, Probe Number = 3, T = 20.048000 C 15:37:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:37:12 Integrated Voltage Measurement... 15:37:31 Voltage Offset Correction: v_off_ini = 0.000002790 V, v_off_fin = 0.000006992 V 15:37:31 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175448503 Vs 15:37:31 Integrated Voltage Measurement... 15:37:51 Voltage Offset Correction: v_off_ini = 0.000006160 V, v_off_fin = -0.000000429 V 15:37:51 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175303635 Vs 15:37:54 Temperature Measurement, Probe Number = 0, T = 20.466000 C 15:37:55 Temperature Measurement, Probe Number = 1, T = 20.116000 C 15:37:55 Temperature Measurement, Probe Number = 2, T = 20.087000 C 15:37:56 Temperature Measurement, Probe Number = 3, T = 20.049000 C 15:37:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:37:56 Integrated Voltage Measurement... 15:38:15 Voltage Offset Correction: v_off_ini = 0.000001832 V, v_off_fin = 0.000006537 V 15:38:15 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175443315 Vs 15:38:15 Integrated Voltage Measurement... 15:38:35 Voltage Offset Correction: v_off_ini = 0.000005708 V, v_off_fin = -0.000001110 V 15:38:35 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175308090 Vs 15:38:38 Temperature Measurement, Probe Number = 0, T = 20.475000 C 15:38:38 Temperature Measurement, Probe Number = 1, T = 20.115000 C 15:38:39 Temperature Measurement, Probe Number = 2, T = 20.086000 C 15:38:40 Temperature Measurement, Probe Number = 3, T = 20.051000 C 15:38:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:38:40 Integrated Voltage Measurement... 15:38:59 Voltage Offset Correction: v_off_ini = 0.000002228 V, v_off_fin = 0.000006183 V 15:38:59 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175441053 Vs 15:39:00 Integrated Voltage Measurement... 15:39:19 Voltage Offset Correction: v_off_ini = 0.000005256 V, v_off_fin = -0.000000969 V 15:39:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175312421 Vs 15:39:22 Temperature Measurement, Probe Number = 0, T = 20.459000 C 15:39:22 Temperature Measurement, Probe Number = 1, T = 20.115000 C 15:39:23 Temperature Measurement, Probe Number = 2, T = 20.087000 C 15:39:24 Temperature Measurement, Probe Number = 3, T = 20.050000 C 15:39:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 15:39:24 Integrated Voltage Measurement... 15:39:43 Voltage Offset Correction: v_off_ini = 0.000002130 V, v_off_fin = 0.000007034 V 15:39:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175449231 Vs 15:39:44 Integrated Voltage Measurement... 15:40:03 Voltage Offset Correction: v_off_ini = 0.000005724 V, v_off_fin = -0.000000084 V 15:40:03 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175317331 Vs 15:40:06 Temperature Measurement, Probe Number = 0, T = 20.405000 C 15:40:07 Temperature Measurement, Probe Number = 1, T = 20.112000 C 15:40:07 Temperature Measurement, Probe Number = 2, T = 20.084000 C 15:40:08 Temperature Measurement, Probe Number = 3, T = 20.049000 C 15:40:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 15:40:08 Integrated Voltage Measurement... 15:40:27 Voltage Offset Correction: v_off_ini = 0.000001916 V, v_off_fin = 0.000006520 V 15:40:28 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175446820 Vs 15:40:28 Integrated Voltage Measurement... 15:40:47 Voltage Offset Correction: v_off_ini = 0.000006017 V, v_off_fin = -0.000000142 V 15:40:47 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175308318 Vs 16:10:50 Temperature Measurement, Probe Number = 0, T = 20.186000 C 16:10:51 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:10:51 Temperature Measurement, Probe Number = 2, T = 20.070000 C 16:10:52 Temperature Measurement, Probe Number = 3, T = 20.036000 C 16:10:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:10:52 Integrated Voltage Measurement... 16:11:11 Voltage Offset Correction: v_off_ini = 0.000005197 V, v_off_fin = 0.000007097 V 16:11:11 Integrated Voltage Measurement Delta Gap = 0.0040023 m VT = 0.175537135 Vs 16:11:12 Integrated Voltage Measurement... 16:11:31 Voltage Offset Correction: v_off_ini = 0.000006395 V, v_off_fin = -0.000000289 V 16:11:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175316362 Vs 16:11:34 Temperature Measurement, Probe Number = 0, T = 20.193000 C 16:11:35 Temperature Measurement, Probe Number = 1, T = 20.107000 C 16:11:35 Temperature Measurement, Probe Number = 2, T = 20.068000 C 16:11:36 Temperature Measurement, Probe Number = 3, T = 20.040000 C 16:11:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:11:36 Integrated Voltage Measurement... 16:11:56 Voltage Offset Correction: v_off_ini = 0.000003343 V, v_off_fin = 0.000006630 V 16:11:56 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175463290 Vs 16:11:56 Integrated Voltage Measurement... 16:12:16 Voltage Offset Correction: v_off_ini = 0.000006372 V, v_off_fin = -0.000000261 V 16:12:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175315450 Vs 16:12:18 Temperature Measurement, Probe Number = 0, T = 20.170000 C 16:12:19 Temperature Measurement, Probe Number = 1, T = 20.107000 C 16:12:20 Temperature Measurement, Probe Number = 2, T = 20.062000 C 16:12:20 Temperature Measurement, Probe Number = 3, T = 20.041000 C 16:12:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 16:12:21 Integrated Voltage Measurement... 16:12:40 Voltage Offset Correction: v_off_ini = 0.000002541 V, v_off_fin = 0.000007205 V 16:12:40 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175467460 Vs 16:12:40 Integrated Voltage Measurement... 16:12:59 Voltage Offset Correction: v_off_ini = 0.000006732 V, v_off_fin = 0.000000614 V 16:13:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313394 Vs 16:13:02 Temperature Measurement, Probe Number = 0, T = 20.128000 C 16:13:03 Temperature Measurement, Probe Number = 1, T = 20.107000 C 16:13:04 Temperature Measurement, Probe Number = 2, T = 20.064000 C 16:13:04 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:13:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 16:13:04 Integrated Voltage Measurement... 16:13:23 Voltage Offset Correction: v_off_ini = 0.000002788 V, v_off_fin = 0.000007551 V 16:13:24 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175471099 Vs 16:13:24 Integrated Voltage Measurement... 16:13:43 Voltage Offset Correction: v_off_ini = 0.000006806 V, v_off_fin = 0.000000124 V 16:13:43 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175314953 Vs 16:13:46 Temperature Measurement, Probe Number = 0, T = 20.109000 C 16:13:47 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:13:47 Temperature Measurement, Probe Number = 2, T = 20.067000 C 16:13:48 Temperature Measurement, Probe Number = 3, T = 20.043000 C 16:13:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:13:48 Integrated Voltage Measurement... 16:14:07 Voltage Offset Correction: v_off_ini = 0.000002842 V, v_off_fin = 0.000007524 V 16:14:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175470870 Vs 16:14:08 Integrated Voltage Measurement... 16:14:27 Voltage Offset Correction: v_off_ini = 0.000006504 V, v_off_fin = 0.000000124 V 16:14:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175326026 Vs 16:14:30 Temperature Measurement, Probe Number = 0, T = 20.102000 C 16:14:31 Temperature Measurement, Probe Number = 1, T = 20.108000 C 16:14:31 Temperature Measurement, Probe Number = 2, T = 20.067000 C 16:14:32 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:14:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:14:32 Integrated Voltage Measurement... 16:14:51 Voltage Offset Correction: v_off_ini = 0.000002625 V, v_off_fin = 0.000006935 V 16:14:52 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175466879 Vs 16:14:52 Integrated Voltage Measurement... 16:15:11 Voltage Offset Correction: v_off_ini = 0.000006606 V, v_off_fin = -0.000001097 V 16:15:11 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175329940 Vs 16:15:14 Temperature Measurement, Probe Number = 0, T = 20.112000 C 16:15:15 Temperature Measurement, Probe Number = 1, T = 20.109000 C 16:15:15 Temperature Measurement, Probe Number = 2, T = 20.070000 C 16:15:16 Temperature Measurement, Probe Number = 3, T = 20.041000 C 16:15:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:15:16 Integrated Voltage Measurement... 16:15:35 Voltage Offset Correction: v_off_ini = 0.000002446 V, v_off_fin = 0.000007417 V 16:15:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175473281 Vs 16:15:36 Integrated Voltage Measurement... 16:15:55 Voltage Offset Correction: v_off_ini = 0.000007015 V, v_off_fin = 0.000000618 V 16:15:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175323640 Vs 16:15:58 Temperature Measurement, Probe Number = 0, T = 20.126000 C 16:15:59 Temperature Measurement, Probe Number = 1, T = 20.108000 C 16:16:00 Temperature Measurement, Probe Number = 2, T = 20.069000 C 16:16:00 Temperature Measurement, Probe Number = 3, T = 20.032000 C 16:16:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 16:16:01 Integrated Voltage Measurement... 16:16:20 Voltage Offset Correction: v_off_ini = 0.000002901 V, v_off_fin = 0.000007986 V 16:16:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175472875 Vs 16:16:20 Integrated Voltage Measurement... 16:16:39 Voltage Offset Correction: v_off_ini = 0.000006967 V, v_off_fin = 0.000000104 V 16:16:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175319806 Vs 16:16:42 Temperature Measurement, Probe Number = 0, T = 20.113000 C 16:16:43 Temperature Measurement, Probe Number = 1, T = 20.106000 C 16:16:43 Temperature Measurement, Probe Number = 2, T = 20.069000 C 16:16:44 Temperature Measurement, Probe Number = 3, T = 20.033000 C 16:16:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 16:16:44 Integrated Voltage Measurement... 16:17:04 Voltage Offset Correction: v_off_ini = 0.000003639 V, v_off_fin = 0.000007729 V 16:17:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175475910 Vs 16:17:04 Integrated Voltage Measurement... 16:17:24 Voltage Offset Correction: v_off_ini = 0.000006598 V, v_off_fin = 0.000000696 V 16:17:24 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175321427 Vs 16:17:27 Temperature Measurement, Probe Number = 0, T = 20.131000 C 16:17:28 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:17:28 Temperature Measurement, Probe Number = 2, T = 20.058000 C 16:17:29 Temperature Measurement, Probe Number = 3, T = 20.031000 C 16:17:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:17:29 Integrated Voltage Measurement... 16:17:48 Voltage Offset Correction: v_off_ini = 0.000002999 V, v_off_fin = 0.000007522 V 16:17:49 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175472812 Vs 16:17:49 Integrated Voltage Measurement... 16:18:08 Voltage Offset Correction: v_off_ini = 0.000006768 V, v_off_fin = -0.000000046 V 16:18:08 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175318516 Vs 16:48:11 Temperature Measurement, Probe Number = 0, T = 20.161000 C 16:48:12 Temperature Measurement, Probe Number = 1, T = 20.100000 C 16:48:12 Temperature Measurement, Probe Number = 2, T = 20.066000 C 16:48:13 Temperature Measurement, Probe Number = 3, T = 20.028000 C 16:48:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 16:48:13 Integrated Voltage Measurement... 16:48:32 Voltage Offset Correction: v_off_ini = 0.000005294 V, v_off_fin = 0.000007154 V 16:48:32 Integrated Voltage Measurement Delta Gap = 0.0040026 m VT = 0.175561698 Vs 16:48:33 Integrated Voltage Measurement... 16:48:52 Voltage Offset Correction: v_off_ini = 0.000006224 V, v_off_fin = -0.000002204 V 16:48:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175326841 Vs 16:48:55 Temperature Measurement, Probe Number = 0, T = 20.095000 C 16:48:55 Temperature Measurement, Probe Number = 1, T = 20.099000 C 16:48:56 Temperature Measurement, Probe Number = 2, T = 20.055000 C 16:48:57 Temperature Measurement, Probe Number = 3, T = 20.026000 C 16:48:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 16:48:57 Integrated Voltage Measurement... 16:49:17 Voltage Offset Correction: v_off_ini = 0.000002326 V, v_off_fin = 0.000006772 V 16:49:17 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175481618 Vs 16:49:17 Integrated Voltage Measurement... 16:49:37 Voltage Offset Correction: v_off_ini = 0.000006559 V, v_off_fin = 0.000000579 V 16:49:37 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175335158 Vs 16:49:40 Temperature Measurement, Probe Number = 0, T = 20.072000 C 16:49:41 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:49:41 Temperature Measurement, Probe Number = 2, T = 20.062000 C 16:49:42 Temperature Measurement, Probe Number = 3, T = 20.027000 C 16:49:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:49:42 Integrated Voltage Measurement... 16:50:02 Voltage Offset Correction: v_off_ini = 0.000003168 V, v_off_fin = 0.000006497 V 16:50:03 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175471034 Vs 16:50:03 Integrated Voltage Measurement... 16:50:23 Voltage Offset Correction: v_off_ini = 0.000006140 V, v_off_fin = 0.000000722 V 16:50:23 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.175329930 Vs 16:50:26 Temperature Measurement, Probe Number = 0, T = 20.083000 C 16:50:27 Temperature Measurement, Probe Number = 1, T = 20.104000 C 16:50:27 Temperature Measurement, Probe Number = 2, T = 20.063000 C 16:50:28 Temperature Measurement, Probe Number = 3, T = 20.030000 C 16:50:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:50:28 Integrated Voltage Measurement... 16:50:47 Voltage Offset Correction: v_off_ini = 0.000003082 V, v_off_fin = 0.000007012 V 16:50:48 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175461794 Vs 16:50:48 Integrated Voltage Measurement... 16:51:07 Voltage Offset Correction: v_off_ini = 0.000006507 V, v_off_fin = -0.000000686 V 16:51:07 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328199 Vs 16:51:10 Temperature Measurement, Probe Number = 0, T = 20.043000 C 16:51:10 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:51:11 Temperature Measurement, Probe Number = 2, T = 20.061000 C 16:51:12 Temperature Measurement, Probe Number = 3, T = 20.030000 C 16:51:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:51:12 Integrated Voltage Measurement... 16:51:31 Voltage Offset Correction: v_off_ini = 0.000002141 V, v_off_fin = 0.000006920 V 16:51:31 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175475556 Vs 16:51:31 Integrated Voltage Measurement... 16:51:50 Voltage Offset Correction: v_off_ini = 0.000006455 V, v_off_fin = -0.000000508 V 16:51:51 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328563 Vs 16:51:53 Temperature Measurement, Probe Number = 0, T = 20.098000 C 16:51:54 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:51:55 Temperature Measurement, Probe Number = 2, T = 20.062000 C 16:51:55 Temperature Measurement, Probe Number = 3, T = 20.028000 C 16:51:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:51:56 Integrated Voltage Measurement... 16:52:15 Voltage Offset Correction: v_off_ini = 0.000002904 V, v_off_fin = 0.000007473 V 16:52:15 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175485779 Vs 16:52:15 Integrated Voltage Measurement... 16:52:34 Voltage Offset Correction: v_off_ini = 0.000006853 V, v_off_fin = -0.000000179 V 16:52:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175327623 Vs 16:52:37 Temperature Measurement, Probe Number = 0, T = 20.149000 C 16:52:38 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:52:38 Temperature Measurement, Probe Number = 2, T = 20.061000 C 16:52:39 Temperature Measurement, Probe Number = 3, T = 20.033000 C 16:52:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:52:39 Integrated Voltage Measurement... 16:52:59 Voltage Offset Correction: v_off_ini = 0.000003194 V, v_off_fin = 0.000007686 V 16:52:59 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175492430 Vs 16:52:59 Integrated Voltage Measurement... 16:53:18 Voltage Offset Correction: v_off_ini = 0.000006734 V, v_off_fin = 0.000000078 V 16:53:18 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175325737 Vs 16:53:21 Temperature Measurement, Probe Number = 0, T = 20.195000 C 16:53:21 Temperature Measurement, Probe Number = 1, T = 20.100000 C 16:53:22 Temperature Measurement, Probe Number = 2, T = 20.060000 C 16:53:23 Temperature Measurement, Probe Number = 3, T = 20.030000 C 16:53:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 16:53:23 Integrated Voltage Measurement... 16:53:42 Voltage Offset Correction: v_off_ini = 0.000003531 V, v_off_fin = 0.000007800 V 16:53:42 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175485598 Vs 16:53:42 Integrated Voltage Measurement... 16:54:02 Voltage Offset Correction: v_off_ini = 0.000006982 V, v_off_fin = -0.000000215 V 16:54:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175333613 Vs 16:54:04 Temperature Measurement, Probe Number = 0, T = 20.184000 C 16:54:05 Temperature Measurement, Probe Number = 1, T = 20.092000 C 16:54:06 Temperature Measurement, Probe Number = 2, T = 20.053000 C 16:54:06 Temperature Measurement, Probe Number = 3, T = 20.022000 C 16:54:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 16:54:07 Integrated Voltage Measurement... 16:54:26 Voltage Offset Correction: v_off_ini = 0.000002269 V, v_off_fin = 0.000007204 V 16:54:26 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175481018 Vs 16:54:26 Integrated Voltage Measurement... 16:54:45 Voltage Offset Correction: v_off_ini = 0.000006296 V, v_off_fin = -0.000000883 V 16:54:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328803 Vs 16:54:48 Temperature Measurement, Probe Number = 0, T = 20.062000 C 16:54:49 Temperature Measurement, Probe Number = 1, T = 20.093000 C 16:54:49 Temperature Measurement, Probe Number = 2, T = 20.054000 C 16:54:50 Temperature Measurement, Probe Number = 3, T = 20.021000 C 16:54:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 16:54:50 Integrated Voltage Measurement... 16:55:09 Voltage Offset Correction: v_off_ini = 0.000002523 V, v_off_fin = 0.000007480 V 16:55:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175481630 Vs 16:55:10 Integrated Voltage Measurement... 16:55:29 Voltage Offset Correction: v_off_ini = 0.000006739 V, v_off_fin = -0.000000021 V 16:55:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175333389 Vs 17:25:32 Temperature Measurement, Probe Number = 0, T = 20.119000 C 17:25:33 Temperature Measurement, Probe Number = 1, T = 20.087000 C 17:25:33 Temperature Measurement, Probe Number = 2, T = 20.048000 C 17:25:34 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:25:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 17:25:34 Integrated Voltage Measurement... 17:25:53 Voltage Offset Correction: v_off_ini = 0.000005324 V, v_off_fin = 0.000007169 V 17:25:54 Integrated Voltage Measurement Delta Gap = 0.0040027 m VT = 0.175569894 Vs 17:25:54 Integrated Voltage Measurement... 17:26:14 Voltage Offset Correction: v_off_ini = 0.000006227 V, v_off_fin = 0.000000697 V 17:26:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175333961 Vs 17:26:17 Temperature Measurement, Probe Number = 0, T = 20.106000 C 17:26:18 Temperature Measurement, Probe Number = 1, T = 20.085000 C 17:26:19 Temperature Measurement, Probe Number = 2, T = 20.047000 C 17:26:19 Temperature Measurement, Probe Number = 3, T = 20.019000 C 17:26:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 17:26:19 Integrated Voltage Measurement... 17:26:39 Voltage Offset Correction: v_off_ini = 0.000002340 V, v_off_fin = 0.000007182 V 17:26:39 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175464334 Vs 17:26:39 Integrated Voltage Measurement... 17:26:59 Voltage Offset Correction: v_off_ini = 0.000006518 V, v_off_fin = 0.000000123 V 17:26:59 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175337713 Vs 17:27:02 Temperature Measurement, Probe Number = 0, T = 20.098000 C 17:27:02 Temperature Measurement, Probe Number = 1, T = 20.082000 C 17:27:03 Temperature Measurement, Probe Number = 2, T = 20.048000 C 17:27:04 Temperature Measurement, Probe Number = 3, T = 20.018000 C 17:27:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 17:27:04 Integrated Voltage Measurement... 17:27:23 Voltage Offset Correction: v_off_ini = 0.000003490 V, v_off_fin = 0.000007202 V 17:27:23 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175486249 Vs 17:27:24 Integrated Voltage Measurement... 17:27:43 Voltage Offset Correction: v_off_ini = 0.000006464 V, v_off_fin = 0.000000543 V 17:27:43 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175329602 Vs 17:27:46 Temperature Measurement, Probe Number = 0, T = 20.073000 C 17:27:46 Temperature Measurement, Probe Number = 1, T = 20.081000 C 17:27:47 Temperature Measurement, Probe Number = 2, T = 20.048000 C 17:27:48 Temperature Measurement, Probe Number = 3, T = 20.020000 C 17:27:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 17:27:48 Integrated Voltage Measurement... 17:28:07 Voltage Offset Correction: v_off_ini = 0.000002757 V, v_off_fin = 0.000007493 V 17:28:07 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175490525 Vs 17:28:08 Integrated Voltage Measurement... 17:28:27 Voltage Offset Correction: v_off_ini = 0.000006974 V, v_off_fin = -0.000000676 V 17:28:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175341305 Vs 17:28:30 Temperature Measurement, Probe Number = 0, T = 20.096000 C 17:28:31 Temperature Measurement, Probe Number = 1, T = 20.080000 C 17:28:31 Temperature Measurement, Probe Number = 2, T = 20.043000 C 17:28:32 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:28:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:28:32 Integrated Voltage Measurement... 17:28:51 Voltage Offset Correction: v_off_ini = 0.000002934 V, v_off_fin = 0.000007625 V 17:28:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175488681 Vs 17:28:52 Integrated Voltage Measurement... 17:29:11 Voltage Offset Correction: v_off_ini = 0.000006678 V, v_off_fin = 0.000000206 V 17:29:11 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175331024 Vs 17:29:14 Temperature Measurement, Probe Number = 0, T = 20.077000 C 17:29:15 Temperature Measurement, Probe Number = 1, T = 20.083000 C 17:29:15 Temperature Measurement, Probe Number = 2, T = 20.041000 C 17:29:16 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:29:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:29:16 Integrated Voltage Measurement... 17:29:35 Voltage Offset Correction: v_off_ini = 0.000003391 V, v_off_fin = 0.000006792 V 17:29:35 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175477610 Vs 17:29:36 Integrated Voltage Measurement... 17:29:55 Voltage Offset Correction: v_off_ini = 0.000006271 V, v_off_fin = -0.000001438 V 17:29:55 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175341365 Vs 17:29:58 Temperature Measurement, Probe Number = 0, T = 20.101000 C 17:29:59 Temperature Measurement, Probe Number = 1, T = 20.085000 C 17:29:59 Temperature Measurement, Probe Number = 2, T = 20.044000 C 17:30:00 Temperature Measurement, Probe Number = 3, T = 20.013000 C 17:30:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:30:00 Integrated Voltage Measurement... 17:30:19 Voltage Offset Correction: v_off_ini = 0.000002801 V, v_off_fin = 0.000006729 V 17:30:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175480952 Vs 17:30:20 Integrated Voltage Measurement... 17:30:39 Voltage Offset Correction: v_off_ini = 0.000005797 V, v_off_fin = -0.000000197 V 17:30:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175335099 Vs 17:30:42 Temperature Measurement, Probe Number = 0, T = 20.126000 C 17:30:43 Temperature Measurement, Probe Number = 1, T = 20.085000 C 17:30:44 Temperature Measurement, Probe Number = 2, T = 20.043000 C 17:30:44 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:30:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:30:44 Integrated Voltage Measurement... 17:31:04 Voltage Offset Correction: v_off_ini = 0.000003175 V, v_off_fin = 0.000007114 V 17:31:04 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175484306 Vs 17:31:04 Integrated Voltage Measurement... 17:31:23 Voltage Offset Correction: v_off_ini = 0.000006170 V, v_off_fin = -0.000000461 V 17:31:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175335506 Vs 17:31:26 Temperature Measurement, Probe Number = 0, T = 20.116000 C 17:31:27 Temperature Measurement, Probe Number = 1, T = 20.084000 C 17:31:28 Temperature Measurement, Probe Number = 2, T = 20.046000 C 17:31:28 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:31:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 17:31:28 Integrated Voltage Measurement... 17:31:47 Voltage Offset Correction: v_off_ini = 0.000003089 V, v_off_fin = 0.000006839 V 17:31:48 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175482630 Vs 17:31:48 Integrated Voltage Measurement... 17:32:07 Voltage Offset Correction: v_off_ini = 0.000006386 V, v_off_fin = -0.000000307 V 17:32:07 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175343437 Vs 17:32:10 Temperature Measurement, Probe Number = 0, T = 20.149000 C 17:32:11 Temperature Measurement, Probe Number = 1, T = 20.086000 C 17:32:12 Temperature Measurement, Probe Number = 2, T = 20.046000 C 17:32:12 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:32:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 17:32:12 Integrated Voltage Measurement... 17:32:32 Voltage Offset Correction: v_off_ini = 0.000002935 V, v_off_fin = 0.000007816 V 17:32:32 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175487777 Vs 17:32:32 Integrated Voltage Measurement... 17:32:51 Voltage Offset Correction: v_off_ini = 0.000006865 V, v_off_fin = 0.000000330 V 17:32:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328449 Vs 18:02:54 Temperature Measurement, Probe Number = 0, T = 20.147000 C 18:02:55 Temperature Measurement, Probe Number = 1, T = 20.075000 C 18:02:56 Temperature Measurement, Probe Number = 2, T = 20.041000 C 18:02:56 Temperature Measurement, Probe Number = 3, T = 20.009000 C 18:02:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:02:57 Integrated Voltage Measurement... 18:03:16 Voltage Offset Correction: v_off_ini = 0.000004803 V, v_off_fin = 0.000007071 V 18:03:16 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175587806 Vs 18:03:17 Integrated Voltage Measurement... 18:03:36 Voltage Offset Correction: v_off_ini = 0.000006544 V, v_off_fin = -0.000000416 V 18:03:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175329462 Vs 18:03:39 Temperature Measurement, Probe Number = 0, T = 20.178000 C 18:03:39 Temperature Measurement, Probe Number = 1, T = 20.077000 C 18:03:40 Temperature Measurement, Probe Number = 2, T = 20.044000 C 18:03:41 Temperature Measurement, Probe Number = 3, T = 20.013000 C 18:03:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:03:41 Integrated Voltage Measurement... 18:04:00 Voltage Offset Correction: v_off_ini = 0.000002782 V, v_off_fin = 0.000007170 V 18:04:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175481369 Vs 18:04:01 Integrated Voltage Measurement... 18:04:20 Voltage Offset Correction: v_off_ini = 0.000006571 V, v_off_fin = -0.000000283 V 18:04:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321176 Vs 18:04:23 Temperature Measurement, Probe Number = 0, T = 20.178000 C 18:04:23 Temperature Measurement, Probe Number = 1, T = 20.077000 C 18:04:24 Temperature Measurement, Probe Number = 2, T = 20.042000 C 18:04:24 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:04:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 18:04:25 Integrated Voltage Measurement... 18:04:44 Voltage Offset Correction: v_off_ini = 0.000003004 V, v_off_fin = 0.000007741 V 18:04:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175484337 Vs 18:04:44 Integrated Voltage Measurement... 18:05:03 Voltage Offset Correction: v_off_ini = 0.000007017 V, v_off_fin = -0.000000089 V 18:05:03 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175318867 Vs 18:05:06 Temperature Measurement, Probe Number = 0, T = 20.186000 C 18:05:07 Temperature Measurement, Probe Number = 1, T = 20.082000 C 18:05:07 Temperature Measurement, Probe Number = 2, T = 20.043000 C 18:05:08 Temperature Measurement, Probe Number = 3, T = 20.009000 C 18:05:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:05:08 Integrated Voltage Measurement... 18:05:28 Voltage Offset Correction: v_off_ini = 0.000002458 V, v_off_fin = 0.000006941 V 18:05:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175479385 Vs 18:05:28 Integrated Voltage Measurement... 18:05:47 Voltage Offset Correction: v_off_ini = 0.000006208 V, v_off_fin = -0.000000489 V 18:05:48 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175330416 Vs 18:05:50 Temperature Measurement, Probe Number = 0, T = 20.156000 C 18:05:51 Temperature Measurement, Probe Number = 1, T = 20.079000 C 18:05:52 Temperature Measurement, Probe Number = 2, T = 20.039000 C 18:05:52 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:05:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:05:52 Integrated Voltage Measurement... 18:06:12 Voltage Offset Correction: v_off_ini = 0.000002355 V, v_off_fin = 0.000006920 V 18:06:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175475942 Vs 18:06:12 Integrated Voltage Measurement... 18:06:32 Voltage Offset Correction: v_off_ini = 0.000006059 V, v_off_fin = -0.000000082 V 18:06:32 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175341335 Vs 18:06:35 Temperature Measurement, Probe Number = 0, T = 20.185000 C 18:06:35 Temperature Measurement, Probe Number = 1, T = 20.077000 C 18:06:36 Temperature Measurement, Probe Number = 2, T = 20.039000 C 18:06:37 Temperature Measurement, Probe Number = 3, T = 20.007000 C 18:06:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:06:37 Integrated Voltage Measurement... 18:06:56 Voltage Offset Correction: v_off_ini = 0.000002495 V, v_off_fin = 0.000007016 V 18:06:56 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175471395 Vs 18:06:56 Integrated Voltage Measurement... 18:07:15 Voltage Offset Correction: v_off_ini = 0.000006635 V, v_off_fin = 0.000000424 V 18:07:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175330742 Vs 18:07:18 Temperature Measurement, Probe Number = 0, T = 20.192000 C 18:07:19 Temperature Measurement, Probe Number = 1, T = 20.077000 C 18:07:20 Temperature Measurement, Probe Number = 2, T = 20.041000 C 18:07:20 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:07:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:07:21 Integrated Voltage Measurement... 18:07:40 Voltage Offset Correction: v_off_ini = 0.000002932 V, v_off_fin = 0.000007320 V 18:07:40 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175484798 Vs 18:07:40 Integrated Voltage Measurement... 18:08:00 Voltage Offset Correction: v_off_ini = 0.000007054 V, v_off_fin = -0.000000222 V 18:08:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328443 Vs 18:08:03 Temperature Measurement, Probe Number = 0, T = 20.179000 C 18:08:03 Temperature Measurement, Probe Number = 1, T = 20.078000 C 18:08:04 Temperature Measurement, Probe Number = 2, T = 20.044000 C 18:08:05 Temperature Measurement, Probe Number = 3, T = 20.011000 C 18:08:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:08:05 Integrated Voltage Measurement... 18:08:25 Voltage Offset Correction: v_off_ini = 0.000003079 V, v_off_fin = 0.000007090 V 18:08:25 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175483718 Vs 18:08:25 Integrated Voltage Measurement... 18:08:44 Voltage Offset Correction: v_off_ini = 0.000006684 V, v_off_fin = -0.000000495 V 18:08:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175324370 Vs 18:08:47 Temperature Measurement, Probe Number = 0, T = 20.146000 C 18:08:48 Temperature Measurement, Probe Number = 1, T = 20.081000 C 18:08:48 Temperature Measurement, Probe Number = 2, T = 20.045000 C 18:08:49 Temperature Measurement, Probe Number = 3, T = 20.011000 C 18:08:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 18:08:49 Integrated Voltage Measurement... 18:09:08 Voltage Offset Correction: v_off_ini = 0.000003291 V, v_off_fin = 0.000007494 V 18:09:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175489988 Vs 18:09:09 Integrated Voltage Measurement... 18:09:28 Voltage Offset Correction: v_off_ini = 0.000007006 V, v_off_fin = -0.000000734 V 18:09:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175330074 Vs 18:09:31 Temperature Measurement, Probe Number = 0, T = 20.192000 C 18:09:32 Temperature Measurement, Probe Number = 1, T = 20.080000 C 18:09:32 Temperature Measurement, Probe Number = 2, T = 20.045000 C 18:09:33 Temperature Measurement, Probe Number = 3, T = 20.012000 C 18:09:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 18:09:33 Integrated Voltage Measurement... 18:09:52 Voltage Offset Correction: v_off_ini = 0.000002292 V, v_off_fin = 0.000007284 V 18:09:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175492050 Vs 18:09:52 Integrated Voltage Measurement... 18:10:12 Voltage Offset Correction: v_off_ini = 0.000006803 V, v_off_fin = -0.000000665 V 18:10:12 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175327953 Vs 18:40:15 Temperature Measurement, Probe Number = 0, T = 20.170000 C 18:40:15 Temperature Measurement, Probe Number = 1, T = 20.069000 C 18:40:16 Temperature Measurement, Probe Number = 2, T = 20.033000 C 18:40:17 Temperature Measurement, Probe Number = 3, T = 19.997000 C 18:40:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:40:17 Integrated Voltage Measurement... 18:40:36 Voltage Offset Correction: v_off_ini = 0.000005157 V, v_off_fin = 0.000007169 V 18:40:36 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175572164 Vs 18:40:36 Integrated Voltage Measurement... 18:40:56 Voltage Offset Correction: v_off_ini = 0.000006233 V, v_off_fin = 0.000000215 V 18:40:56 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175319677 Vs 18:40:58 Temperature Measurement, Probe Number = 0, T = 20.142000 C 18:40:59 Temperature Measurement, Probe Number = 1, T = 20.069000 C 18:41:00 Temperature Measurement, Probe Number = 2, T = 20.032000 C 18:41:00 Temperature Measurement, Probe Number = 3, T = 19.996000 C 18:41:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:41:01 Integrated Voltage Measurement... 18:41:20 Voltage Offset Correction: v_off_ini = 0.000003002 V, v_off_fin = 0.000007402 V 18:41:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175472634 Vs 18:41:20 Integrated Voltage Measurement... 18:41:40 Voltage Offset Correction: v_off_ini = 0.000006342 V, v_off_fin = 0.000000978 V 18:41:40 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175319346 Vs 18:41:43 Temperature Measurement, Probe Number = 0, T = 20.131000 C 18:41:43 Temperature Measurement, Probe Number = 1, T = 20.069000 C 18:41:44 Temperature Measurement, Probe Number = 2, T = 20.033000 C 18:41:45 Temperature Measurement, Probe Number = 3, T = 19.994000 C 18:41:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 18:41:45 Integrated Voltage Measurement... 18:42:04 Voltage Offset Correction: v_off_ini = 0.000003256 V, v_off_fin = 0.000007227 V 18:42:04 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175474561 Vs 18:42:04 Integrated Voltage Measurement... 18:42:24 Voltage Offset Correction: v_off_ini = 0.000006711 V, v_off_fin = -0.000001067 V 18:42:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175330941 Vs 18:42:27 Temperature Measurement, Probe Number = 0, T = 20.128000 C 18:42:27 Temperature Measurement, Probe Number = 1, T = 20.070000 C 18:42:28 Temperature Measurement, Probe Number = 2, T = 20.033000 C 18:42:29 Temperature Measurement, Probe Number = 3, T = 19.998000 C 18:42:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:42:29 Integrated Voltage Measurement... 18:42:49 Voltage Offset Correction: v_off_ini = 0.000002065 V, v_off_fin = 0.000007201 V 18:42:49 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175469707 Vs 18:42:49 Integrated Voltage Measurement... 18:43:08 Voltage Offset Correction: v_off_ini = 0.000006971 V, v_off_fin = -0.000000579 V 18:43:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175322660 Vs 18:43:11 Temperature Measurement, Probe Number = 0, T = 20.200000 C 18:43:12 Temperature Measurement, Probe Number = 1, T = 20.075000 C 18:43:13 Temperature Measurement, Probe Number = 2, T = 20.037000 C 18:43:13 Temperature Measurement, Probe Number = 3, T = 19.999000 C 18:43:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 18:43:13 Integrated Voltage Measurement... 18:43:33 Voltage Offset Correction: v_off_ini = 0.000003661 V, v_off_fin = 0.000007285 V 18:43:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175483227 Vs 18:43:34 Integrated Voltage Measurement... 18:43:53 Voltage Offset Correction: v_off_ini = 0.000006355 V, v_off_fin = 0.000000536 V 18:43:53 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175326358 Vs 18:43:56 Temperature Measurement, Probe Number = 0, T = 20.201000 C 18:43:57 Temperature Measurement, Probe Number = 1, T = 20.075000 C 18:43:57 Temperature Measurement, Probe Number = 2, T = 20.040000 C 18:43:58 Temperature Measurement, Probe Number = 3, T = 20.001000 C 18:43:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 18:43:58 Integrated Voltage Measurement... 18:44:17 Voltage Offset Correction: v_off_ini = 0.000002176 V, v_off_fin = 0.000007461 V 18:44:18 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175470463 Vs 18:44:18 Integrated Voltage Measurement... 18:44:37 Voltage Offset Correction: v_off_ini = 0.000006482 V, v_off_fin = -0.000000536 V 18:44:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175324905 Vs 18:44:40 Temperature Measurement, Probe Number = 0, T = 20.238000 C 18:44:41 Temperature Measurement, Probe Number = 1, T = 20.076000 C 18:44:41 Temperature Measurement, Probe Number = 2, T = 20.040000 C 18:44:42 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:44:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 18:44:42 Integrated Voltage Measurement... 18:45:01 Voltage Offset Correction: v_off_ini = 0.000002333 V, v_off_fin = 0.000007281 V 18:45:02 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175478013 Vs 18:45:02 Integrated Voltage Measurement... 18:45:21 Voltage Offset Correction: v_off_ini = 0.000006312 V, v_off_fin = -0.000000353 V 18:45:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175330820 Vs 18:45:24 Temperature Measurement, Probe Number = 0, T = 20.228000 C 18:45:25 Temperature Measurement, Probe Number = 1, T = 20.073000 C 18:45:25 Temperature Measurement, Probe Number = 2, T = 20.037000 C 18:45:26 Temperature Measurement, Probe Number = 3, T = 20.002000 C 18:45:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 18:45:26 Integrated Voltage Measurement... 18:45:45 Voltage Offset Correction: v_off_ini = 0.000002619 V, v_off_fin = 0.000007465 V 18:45:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175478136 Vs 18:45:46 Integrated Voltage Measurement... 18:46:05 Voltage Offset Correction: v_off_ini = 0.000006516 V, v_off_fin = -0.000001055 V 18:46:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175338445 Vs 18:46:08 Temperature Measurement, Probe Number = 0, T = 20.192000 C 18:46:09 Temperature Measurement, Probe Number = 1, T = 20.068000 C 18:46:10 Temperature Measurement, Probe Number = 2, T = 20.030000 C 18:46:10 Temperature Measurement, Probe Number = 3, T = 19.995000 C 18:46:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:46:10 Integrated Voltage Measurement... 18:46:30 Voltage Offset Correction: v_off_ini = 0.000002617 V, v_off_fin = 0.000007330 V 18:46:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175477191 Vs 18:46:30 Integrated Voltage Measurement... 18:46:49 Voltage Offset Correction: v_off_ini = 0.000006870 V, v_off_fin = -0.000000574 V 18:46:50 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175327215 Vs 18:46:52 Temperature Measurement, Probe Number = 0, T = 20.216000 C 18:46:53 Temperature Measurement, Probe Number = 1, T = 20.067000 C 18:46:54 Temperature Measurement, Probe Number = 2, T = 20.030000 C 18:46:54 Temperature Measurement, Probe Number = 3, T = 19.998000 C 18:46:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:46:55 Integrated Voltage Measurement... 18:47:14 Voltage Offset Correction: v_off_ini = 0.000002516 V, v_off_fin = 0.000007372 V 18:47:14 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175477341 Vs 18:47:14 Integrated Voltage Measurement... 18:47:33 Voltage Offset Correction: v_off_ini = 0.000006622 V, v_off_fin = -0.000000049 V 18:47:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324771 Vs 19:17:36 Temperature Measurement, Probe Number = 0, T = 20.244000 C 19:17:37 Temperature Measurement, Probe Number = 1, T = 20.063000 C 19:17:37 Temperature Measurement, Probe Number = 2, T = 20.023000 C 19:17:38 Temperature Measurement, Probe Number = 3, T = 19.990000 C 19:17:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:17:38 Integrated Voltage Measurement... 19:17:57 Voltage Offset Correction: v_off_ini = 0.000004605 V, v_off_fin = 0.000007229 V 19:17:58 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175570100 Vs 19:17:58 Integrated Voltage Measurement... 19:18:17 Voltage Offset Correction: v_off_ini = 0.000006626 V, v_off_fin = 0.000000070 V 19:18:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316527 Vs 19:18:20 Temperature Measurement, Probe Number = 0, T = 20.210000 C 19:18:21 Temperature Measurement, Probe Number = 1, T = 20.058000 C 19:18:21 Temperature Measurement, Probe Number = 2, T = 20.026000 C 19:18:22 Temperature Measurement, Probe Number = 3, T = 19.992000 C 19:18:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:18:22 Integrated Voltage Measurement... 19:18:42 Voltage Offset Correction: v_off_ini = 0.000003155 V, v_off_fin = 0.000007922 V 19:18:42 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175482322 Vs 19:18:42 Integrated Voltage Measurement... 19:19:01 Voltage Offset Correction: v_off_ini = 0.000006545 V, v_off_fin = -0.000000253 V 19:19:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175320989 Vs 19:19:04 Temperature Measurement, Probe Number = 0, T = 20.214000 C 19:19:05 Temperature Measurement, Probe Number = 1, T = 20.062000 C 19:19:06 Temperature Measurement, Probe Number = 2, T = 20.024000 C 19:19:06 Temperature Measurement, Probe Number = 3, T = 19.989000 C 19:19:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:19:07 Integrated Voltage Measurement... 19:19:26 Voltage Offset Correction: v_off_ini = 0.000002826 V, v_off_fin = 0.000007520 V 19:19:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175476267 Vs 19:19:26 Integrated Voltage Measurement... 19:19:45 Voltage Offset Correction: v_off_ini = 0.000006838 V, v_off_fin = -0.000000410 V 19:19:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175323169 Vs 19:19:48 Temperature Measurement, Probe Number = 0, T = 20.185000 C 19:19:49 Temperature Measurement, Probe Number = 1, T = 20.064000 C 19:19:50 Temperature Measurement, Probe Number = 2, T = 20.025000 C 19:19:50 Temperature Measurement, Probe Number = 3, T = 19.988000 C 19:19:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:19:51 Integrated Voltage Measurement... 19:20:10 Voltage Offset Correction: v_off_ini = 0.000003244 V, v_off_fin = 0.000007311 V 19:20:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175473739 Vs 19:20:10 Integrated Voltage Measurement... 19:20:29 Voltage Offset Correction: v_off_ini = 0.000006141 V, v_off_fin = 0.000000006 V 19:20:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319231 Vs 19:20:32 Temperature Measurement, Probe Number = 0, T = 20.184000 C 19:20:33 Temperature Measurement, Probe Number = 1, T = 20.064000 C 19:20:33 Temperature Measurement, Probe Number = 2, T = 20.025000 C 19:20:34 Temperature Measurement, Probe Number = 3, T = 19.991000 C 19:20:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:20:34 Integrated Voltage Measurement... 19:20:54 Voltage Offset Correction: v_off_ini = 0.000003600 V, v_off_fin = 0.000007925 V 19:20:54 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175481496 Vs 19:20:54 Integrated Voltage Measurement... 19:21:13 Voltage Offset Correction: v_off_ini = 0.000006943 V, v_off_fin = -0.000000751 V 19:21:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319918 Vs 19:21:16 Temperature Measurement, Probe Number = 0, T = 20.235000 C 19:21:17 Temperature Measurement, Probe Number = 1, T = 20.064000 C 19:21:17 Temperature Measurement, Probe Number = 2, T = 20.028000 C 19:21:18 Temperature Measurement, Probe Number = 3, T = 19.996000 C 19:21:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:21:18 Integrated Voltage Measurement... 19:21:38 Voltage Offset Correction: v_off_ini = 0.000002751 V, v_off_fin = 0.000007292 V 19:21:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175483058 Vs 19:21:38 Integrated Voltage Measurement... 19:21:57 Voltage Offset Correction: v_off_ini = 0.000006342 V, v_off_fin = 0.000000241 V 19:21:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175330753 Vs 19:22:00 Temperature Measurement, Probe Number = 0, T = 20.206000 C 19:22:01 Temperature Measurement, Probe Number = 1, T = 20.059000 C 19:22:02 Temperature Measurement, Probe Number = 2, T = 20.023000 C 19:22:02 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:22:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:22:03 Integrated Voltage Measurement... 19:22:22 Voltage Offset Correction: v_off_ini = 0.000002800 V, v_off_fin = 0.000007475 V 19:22:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175480229 Vs 19:22:22 Integrated Voltage Measurement... 19:22:41 Voltage Offset Correction: v_off_ini = 0.000006448 V, v_off_fin = -0.000000362 V 19:22:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322242 Vs 19:22:44 Temperature Measurement, Probe Number = 0, T = 20.232000 C 19:22:45 Temperature Measurement, Probe Number = 1, T = 20.063000 C 19:22:46 Temperature Measurement, Probe Number = 2, T = 20.029000 C 19:22:46 Temperature Measurement, Probe Number = 3, T = 19.990000 C 19:22:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:22:47 Integrated Voltage Measurement... 19:23:06 Voltage Offset Correction: v_off_ini = 0.000002408 V, v_off_fin = 0.000007004 V 19:23:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175472347 Vs 19:23:06 Integrated Voltage Measurement... 19:23:25 Voltage Offset Correction: v_off_ini = 0.000006482 V, v_off_fin = -0.000000523 V 19:23:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324646 Vs 19:23:28 Temperature Measurement, Probe Number = 0, T = 20.254000 C 19:23:29 Temperature Measurement, Probe Number = 1, T = 20.061000 C 19:23:29 Temperature Measurement, Probe Number = 2, T = 20.031000 C 19:23:30 Temperature Measurement, Probe Number = 3, T = 19.995000 C 19:23:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:23:30 Integrated Voltage Measurement... 19:23:49 Voltage Offset Correction: v_off_ini = 0.000003052 V, v_off_fin = 0.000007729 V 19:23:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175480927 Vs 19:23:50 Integrated Voltage Measurement... 19:24:09 Voltage Offset Correction: v_off_ini = 0.000006861 V, v_off_fin = -0.000000690 V 19:24:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317697 Vs 19:24:11 Temperature Measurement, Probe Number = 0, T = 20.276000 C 19:24:12 Temperature Measurement, Probe Number = 1, T = 20.063000 C 19:24:13 Temperature Measurement, Probe Number = 2, T = 20.027000 C 19:24:13 Temperature Measurement, Probe Number = 3, T = 19.992000 C 19:24:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:24:14 Integrated Voltage Measurement... 19:24:33 Voltage Offset Correction: v_off_ini = 0.000002767 V, v_off_fin = 0.000007970 V 19:24:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175477172 Vs 19:24:33 Integrated Voltage Measurement... 19:24:52 Voltage Offset Correction: v_off_ini = 0.000006569 V, v_off_fin = -0.000000009 V 19:24:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320003 Vs 19:54:55 Temperature Measurement, Probe Number = 0, T = 20.245000 C 19:54:56 Temperature Measurement, Probe Number = 1, T = 20.057000 C 19:54:56 Temperature Measurement, Probe Number = 2, T = 20.026000 C 19:54:57 Temperature Measurement, Probe Number = 3, T = 19.991000 C 19:54:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:54:57 Integrated Voltage Measurement... 19:55:17 Voltage Offset Correction: v_off_ini = 0.000005755 V, v_off_fin = 0.000007969 V 19:55:17 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175579714 Vs 19:55:17 Integrated Voltage Measurement... 19:55:36 Voltage Offset Correction: v_off_ini = 0.000007080 V, v_off_fin = -0.000000324 V 19:55:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294537 Vs 19:55:39 Temperature Measurement, Probe Number = 0, T = 20.166000 C 19:55:39 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:55:40 Temperature Measurement, Probe Number = 2, T = 20.022000 C 19:55:41 Temperature Measurement, Probe Number = 3, T = 19.989000 C 19:55:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:55:41 Integrated Voltage Measurement... 19:56:00 Voltage Offset Correction: v_off_ini = 0.000002511 V, v_off_fin = 0.000007545 V 19:56:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175454126 Vs 19:56:00 Integrated Voltage Measurement... 19:56:19 Voltage Offset Correction: v_off_ini = 0.000006389 V, v_off_fin = -0.000000419 V 19:56:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311402 Vs 19:56:22 Temperature Measurement, Probe Number = 0, T = 20.099000 C 19:56:23 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:56:24 Temperature Measurement, Probe Number = 2, T = 20.023000 C 19:56:24 Temperature Measurement, Probe Number = 3, T = 19.989000 C 19:56:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 19:56:24 Integrated Voltage Measurement... 19:56:44 Voltage Offset Correction: v_off_ini = 0.000002986 V, v_off_fin = 0.000007349 V 19:56:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175459033 Vs 19:56:44 Integrated Voltage Measurement... 19:57:05 Voltage Offset Correction: v_off_ini = 0.000006730 V, v_off_fin = 0.000000747 V 19:57:05 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175306234 Vs 19:57:07 Temperature Measurement, Probe Number = 0, T = 20.058000 C 19:57:08 Temperature Measurement, Probe Number = 1, T = 20.058000 C 19:57:09 Temperature Measurement, Probe Number = 2, T = 20.026000 C 19:57:09 Temperature Measurement, Probe Number = 3, T = 19.991000 C 19:57:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:57:10 Integrated Voltage Measurement... 19:57:29 Voltage Offset Correction: v_off_ini = 0.000003434 V, v_off_fin = 0.000008189 V 19:57:29 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175449641 Vs 19:57:29 Integrated Voltage Measurement... 19:57:49 Voltage Offset Correction: v_off_ini = 0.000006491 V, v_off_fin = -0.000000182 V 19:57:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305704 Vs 19:57:52 Temperature Measurement, Probe Number = 0, T = 20.113000 C 19:57:52 Temperature Measurement, Probe Number = 1, T = 20.060000 C 19:57:53 Temperature Measurement, Probe Number = 2, T = 20.027000 C 19:57:53 Temperature Measurement, Probe Number = 3, T = 19.993000 C 19:57:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:57:54 Integrated Voltage Measurement... 19:58:13 Voltage Offset Correction: v_off_ini = 0.000002467 V, v_off_fin = 0.000007549 V 19:58:13 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175462242 Vs 19:58:13 Integrated Voltage Measurement... 19:58:33 Voltage Offset Correction: v_off_ini = 0.000006516 V, v_off_fin = 0.000000273 V 19:58:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310634 Vs 19:58:36 Temperature Measurement, Probe Number = 0, T = 20.143000 C 19:58:37 Temperature Measurement, Probe Number = 1, T = 20.060000 C 19:58:37 Temperature Measurement, Probe Number = 2, T = 20.027000 C 19:58:38 Temperature Measurement, Probe Number = 3, T = 19.991000 C 19:58:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:58:38 Integrated Voltage Measurement... 19:58:57 Voltage Offset Correction: v_off_ini = 0.000003049 V, v_off_fin = 0.000007660 V 19:58:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175459296 Vs 19:58:57 Integrated Voltage Measurement... 19:59:17 Voltage Offset Correction: v_off_ini = 0.000006953 V, v_off_fin = 0.000000111 V 19:59:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307569 Vs 19:59:20 Temperature Measurement, Probe Number = 0, T = 20.203000 C 19:59:21 Temperature Measurement, Probe Number = 1, T = 20.059000 C 19:59:21 Temperature Measurement, Probe Number = 2, T = 20.029000 C 19:59:22 Temperature Measurement, Probe Number = 3, T = 19.992000 C 19:59:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 19:59:22 Integrated Voltage Measurement... 19:59:41 Voltage Offset Correction: v_off_ini = 0.000002724 V, v_off_fin = 0.000007439 V 19:59:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175457733 Vs 19:59:42 Integrated Voltage Measurement... 20:00:01 Voltage Offset Correction: v_off_ini = 0.000007117 V, v_off_fin = -0.000000012 V 20:00:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301613 Vs 20:00:04 Temperature Measurement, Probe Number = 0, T = 20.213000 C 20:00:05 Temperature Measurement, Probe Number = 1, T = 20.058000 C 20:00:05 Temperature Measurement, Probe Number = 2, T = 20.025000 C 20:00:06 Temperature Measurement, Probe Number = 3, T = 19.991000 C 20:00:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:00:06 Integrated Voltage Measurement... 20:00:25 Voltage Offset Correction: v_off_ini = 0.000003603 V, v_off_fin = 0.000007445 V 20:00:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175458307 Vs 20:00:26 Integrated Voltage Measurement... 20:00:45 Voltage Offset Correction: v_off_ini = 0.000007135 V, v_off_fin = 0.000000599 V 20:00:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309098 Vs 20:00:48 Temperature Measurement, Probe Number = 0, T = 20.209000 C 20:00:49 Temperature Measurement, Probe Number = 1, T = 20.058000 C 20:00:49 Temperature Measurement, Probe Number = 2, T = 20.025000 C 20:00:50 Temperature Measurement, Probe Number = 3, T = 19.990000 C 20:00:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:00:50 Integrated Voltage Measurement... 20:01:09 Voltage Offset Correction: v_off_ini = 0.000002610 V, v_off_fin = 0.000007631 V 20:01:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175457142 Vs 20:01:10 Integrated Voltage Measurement... 20:01:29 Voltage Offset Correction: v_off_ini = 0.000006989 V, v_off_fin = 0.000000420 V 20:01:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313294 Vs 20:01:32 Temperature Measurement, Probe Number = 0, T = 20.228000 C 20:01:33 Temperature Measurement, Probe Number = 1, T = 20.060000 C 20:01:33 Temperature Measurement, Probe Number = 2, T = 20.025000 C 20:01:34 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:01:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:01:34 Integrated Voltage Measurement... 20:01:54 Voltage Offset Correction: v_off_ini = 0.000002720 V, v_off_fin = 0.000007136 V 20:01:54 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175453888 Vs 20:01:54 Integrated Voltage Measurement... 20:02:15 Voltage Offset Correction: v_off_ini = 0.000006714 V, v_off_fin = 0.000001011 V 20:02:15 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175299747 Vs 20:32:18 Temperature Measurement, Probe Number = 0, T = 20.302000 C 20:32:19 Temperature Measurement, Probe Number = 1, T = 20.056000 C 20:32:20 Temperature Measurement, Probe Number = 2, T = 20.023000 C 20:32:20 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:32:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:32:20 Integrated Voltage Measurement... 20:32:40 Voltage Offset Correction: v_off_ini = 0.000004494 V, v_off_fin = 0.000006689 V 20:32:40 Integrated Voltage Measurement Delta Gap = 0.0040026 m VT = 0.175528665 Vs 20:32:41 Integrated Voltage Measurement... 20:33:00 Voltage Offset Correction: v_off_ini = 0.000006514 V, v_off_fin = 0.000000238 V 20:33:01 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175305460 Vs 20:33:03 Temperature Measurement, Probe Number = 0, T = 20.266000 C 20:33:04 Temperature Measurement, Probe Number = 1, T = 20.055000 C 20:33:05 Temperature Measurement, Probe Number = 2, T = 20.023000 C 20:33:05 Temperature Measurement, Probe Number = 3, T = 19.991000 C 20:33:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:33:05 Integrated Voltage Measurement... 20:33:24 Voltage Offset Correction: v_off_ini = 0.000002684 V, v_off_fin = 0.000007044 V 20:33:25 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175432067 Vs 20:33:25 Integrated Voltage Measurement... 20:33:44 Voltage Offset Correction: v_off_ini = 0.000006394 V, v_off_fin = -0.000000322 V 20:33:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295955 Vs 20:33:47 Temperature Measurement, Probe Number = 0, T = 20.239000 C 20:33:48 Temperature Measurement, Probe Number = 1, T = 20.059000 C 20:33:48 Temperature Measurement, Probe Number = 2, T = 20.023000 C 20:33:49 Temperature Measurement, Probe Number = 3, T = 19.990000 C 20:33:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:33:49 Integrated Voltage Measurement... 20:34:08 Voltage Offset Correction: v_off_ini = 0.000003424 V, v_off_fin = 0.000007527 V 20:34:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175446949 Vs 20:34:09 Integrated Voltage Measurement... 20:34:28 Voltage Offset Correction: v_off_ini = 0.000006431 V, v_off_fin = 0.000000164 V 20:34:28 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297564 Vs 20:34:31 Temperature Measurement, Probe Number = 0, T = 20.183000 C 20:34:32 Temperature Measurement, Probe Number = 1, T = 20.059000 C 20:34:32 Temperature Measurement, Probe Number = 2, T = 20.023000 C 20:34:33 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:34:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:34:33 Integrated Voltage Measurement... 20:34:52 Voltage Offset Correction: v_off_ini = 0.000002288 V, v_off_fin = 0.000006594 V 20:34:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175436886 Vs 20:34:53 Integrated Voltage Measurement... 20:35:12 Voltage Offset Correction: v_off_ini = 0.000006154 V, v_off_fin = -0.000000695 V 20:35:12 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175307584 Vs 20:35:15 Temperature Measurement, Probe Number = 0, T = 20.211000 C 20:35:16 Temperature Measurement, Probe Number = 1, T = 20.058000 C 20:35:16 Temperature Measurement, Probe Number = 2, T = 20.026000 C 20:35:17 Temperature Measurement, Probe Number = 3, T = 19.992000 C 20:35:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 20:35:17 Integrated Voltage Measurement... 20:35:37 Voltage Offset Correction: v_off_ini = 0.000003006 V, v_off_fin = 0.000006986 V 20:35:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175444117 Vs 20:35:37 Integrated Voltage Measurement... 20:35:56 Voltage Offset Correction: v_off_ini = 0.000006199 V, v_off_fin = -0.000000130 V 20:35:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301282 Vs 20:35:59 Temperature Measurement, Probe Number = 0, T = 20.249000 C 20:36:00 Temperature Measurement, Probe Number = 1, T = 20.059000 C 20:36:00 Temperature Measurement, Probe Number = 2, T = 20.027000 C 20:36:01 Temperature Measurement, Probe Number = 3, T = 19.993000 C 20:36:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 20:36:01 Integrated Voltage Measurement... 20:36:20 Voltage Offset Correction: v_off_ini = 0.000002191 V, v_off_fin = 0.000006939 V 20:36:21 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175443504 Vs 20:36:21 Integrated Voltage Measurement... 20:36:40 Voltage Offset Correction: v_off_ini = 0.000006098 V, v_off_fin = 0.000000427 V 20:36:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175303881 Vs 20:36:43 Temperature Measurement, Probe Number = 0, T = 20.278000 C 20:36:44 Temperature Measurement, Probe Number = 1, T = 20.058000 C 20:36:45 Temperature Measurement, Probe Number = 2, T = 20.028000 C 20:36:45 Temperature Measurement, Probe Number = 3, T = 19.995000 C 20:36:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 20:36:46 Integrated Voltage Measurement... 20:37:05 Voltage Offset Correction: v_off_ini = 0.000002469 V, v_off_fin = 0.000006541 V 20:37:05 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175437793 Vs 20:37:05 Integrated Voltage Measurement... 20:37:24 Voltage Offset Correction: v_off_ini = 0.000005936 V, v_off_fin = -0.000000089 V 20:37:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311333 Vs 20:37:27 Temperature Measurement, Probe Number = 0, T = 20.284000 C 20:37:28 Temperature Measurement, Probe Number = 1, T = 20.059000 C 20:37:29 Temperature Measurement, Probe Number = 2, T = 20.028000 C 20:37:29 Temperature Measurement, Probe Number = 3, T = 19.993000 C 20:37:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 20:37:29 Integrated Voltage Measurement... 20:37:49 Voltage Offset Correction: v_off_ini = 0.000002520 V, v_off_fin = 0.000007473 V 20:37:49 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175446514 Vs 20:37:49 Integrated Voltage Measurement... 20:38:09 Voltage Offset Correction: v_off_ini = 0.000006212 V, v_off_fin = -0.000000465 V 20:38:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311444 Vs 20:38:12 Temperature Measurement, Probe Number = 0, T = 20.280000 C 20:38:12 Temperature Measurement, Probe Number = 1, T = 20.060000 C 20:38:13 Temperature Measurement, Probe Number = 2, T = 20.029000 C 20:38:14 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:38:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 20:38:14 Integrated Voltage Measurement... 20:38:33 Voltage Offset Correction: v_off_ini = 0.000002178 V, v_off_fin = 0.000007365 V 20:38:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175444285 Vs 20:38:33 Integrated Voltage Measurement... 20:38:52 Voltage Offset Correction: v_off_ini = 0.000006656 V, v_off_fin = -0.000000516 V 20:38:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297005 Vs 20:38:55 Temperature Measurement, Probe Number = 0, T = 20.335000 C 20:38:56 Temperature Measurement, Probe Number = 1, T = 20.063000 C 20:38:57 Temperature Measurement, Probe Number = 2, T = 20.033000 C 20:38:57 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:38:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 20:38:57 Integrated Voltage Measurement... 20:39:17 Voltage Offset Correction: v_off_ini = 0.000002750 V, v_off_fin = 0.000006949 V 20:39:17 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175442949 Vs 20:39:17 Integrated Voltage Measurement... 20:39:36 Voltage Offset Correction: v_off_ini = 0.000006104 V, v_off_fin = -0.000000264 V 20:39:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302692 Vs 21:09:39 Temperature Measurement, Probe Number = 0, T = 20.309000 C 21:09:40 Temperature Measurement, Probe Number = 1, T = 20.061000 C 21:09:41 Temperature Measurement, Probe Number = 2, T = 20.030000 C 21:09:41 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:09:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:09:41 Integrated Voltage Measurement... 21:10:01 Voltage Offset Correction: v_off_ini = 0.000005378 V, v_off_fin = 0.000007111 V 21:10:01 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175547227 Vs 21:10:01 Integrated Voltage Measurement... 21:10:20 Voltage Offset Correction: v_off_ini = 0.000006394 V, v_off_fin = -0.000000771 V 21:10:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287996 Vs 21:10:23 Temperature Measurement, Probe Number = 0, T = 20.266000 C 21:10:24 Temperature Measurement, Probe Number = 1, T = 20.059000 C 21:10:25 Temperature Measurement, Probe Number = 2, T = 20.028000 C 21:10:25 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:10:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:10:25 Integrated Voltage Measurement... 21:10:45 Voltage Offset Correction: v_off_ini = 0.000002750 V, v_off_fin = 0.000006914 V 21:10:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445128 Vs 21:10:45 Integrated Voltage Measurement... 21:11:04 Voltage Offset Correction: v_off_ini = 0.000006222 V, v_off_fin = -0.000000090 V 21:11:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301622 Vs 21:11:07 Temperature Measurement, Probe Number = 0, T = 20.155000 C 21:11:08 Temperature Measurement, Probe Number = 1, T = 20.058000 C 21:11:09 Temperature Measurement, Probe Number = 2, T = 20.028000 C 21:11:09 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:11:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:11:10 Integrated Voltage Measurement... 21:11:29 Voltage Offset Correction: v_off_ini = 0.000001966 V, v_off_fin = 0.000007002 V 21:11:29 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175430630 Vs 21:11:29 Integrated Voltage Measurement... 21:11:49 Voltage Offset Correction: v_off_ini = 0.000005972 V, v_off_fin = -0.000000204 V 21:11:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300331 Vs 21:11:52 Temperature Measurement, Probe Number = 0, T = 20.130000 C 21:11:52 Temperature Measurement, Probe Number = 1, T = 20.059000 C 21:11:53 Temperature Measurement, Probe Number = 2, T = 20.028000 C 21:11:54 Temperature Measurement, Probe Number = 3, T = 19.999000 C 21:11:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:11:54 Integrated Voltage Measurement... 21:12:13 Voltage Offset Correction: v_off_ini = 0.000002689 V, v_off_fin = 0.000007449 V 21:12:13 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175436225 Vs 21:12:13 Integrated Voltage Measurement... 21:12:33 Voltage Offset Correction: v_off_ini = 0.000006734 V, v_off_fin = -0.000000216 V 21:12:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296169 Vs 21:12:36 Temperature Measurement, Probe Number = 0, T = 20.204000 C 21:12:36 Temperature Measurement, Probe Number = 1, T = 20.059000 C 21:12:37 Temperature Measurement, Probe Number = 2, T = 20.030000 C 21:12:38 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:12:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:12:38 Integrated Voltage Measurement... 21:12:57 Voltage Offset Correction: v_off_ini = 0.000002873 V, v_off_fin = 0.000007400 V 21:12:57 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175438694 Vs 21:12:57 Integrated Voltage Measurement... 21:13:17 Voltage Offset Correction: v_off_ini = 0.000006614 V, v_off_fin = -0.000000352 V 21:13:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301966 Vs 21:13:19 Temperature Measurement, Probe Number = 0, T = 20.234000 C 21:13:20 Temperature Measurement, Probe Number = 1, T = 20.063000 C 21:13:21 Temperature Measurement, Probe Number = 2, T = 20.029000 C 21:13:21 Temperature Measurement, Probe Number = 3, T = 19.998000 C 21:13:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:13:22 Integrated Voltage Measurement... 21:13:41 Voltage Offset Correction: v_off_ini = 0.000002660 V, v_off_fin = 0.000007258 V 21:13:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175438827 Vs 21:13:41 Integrated Voltage Measurement... 21:14:00 Voltage Offset Correction: v_off_ini = 0.000006313 V, v_off_fin = -0.000000107 V 21:14:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292350 Vs 21:14:03 Temperature Measurement, Probe Number = 0, T = 20.292000 C 21:14:04 Temperature Measurement, Probe Number = 1, T = 20.060000 C 21:14:04 Temperature Measurement, Probe Number = 2, T = 20.029000 C 21:14:05 Temperature Measurement, Probe Number = 3, T = 19.999000 C 21:14:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:14:05 Integrated Voltage Measurement... 21:14:24 Voltage Offset Correction: v_off_ini = 0.000002560 V, v_off_fin = 0.000007187 V 21:14:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437070 Vs 21:14:25 Integrated Voltage Measurement... 21:14:44 Voltage Offset Correction: v_off_ini = 0.000006202 V, v_off_fin = -0.000000533 V 21:14:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300907 Vs 21:14:47 Temperature Measurement, Probe Number = 0, T = 20.299000 C 21:14:48 Temperature Measurement, Probe Number = 1, T = 20.059000 C 21:14:48 Temperature Measurement, Probe Number = 2, T = 20.030000 C 21:14:49 Temperature Measurement, Probe Number = 3, T = 20.000000 C 21:14:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:14:49 Integrated Voltage Measurement... 21:15:08 Voltage Offset Correction: v_off_ini = 0.000002645 V, v_off_fin = 0.000006598 V 21:15:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175436296 Vs 21:15:09 Integrated Voltage Measurement... 21:15:28 Voltage Offset Correction: v_off_ini = 0.000006622 V, v_off_fin = -0.000000135 V 21:15:28 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297629 Vs 21:15:31 Temperature Measurement, Probe Number = 0, T = 20.288000 C 21:15:32 Temperature Measurement, Probe Number = 1, T = 20.060000 C 21:15:32 Temperature Measurement, Probe Number = 2, T = 20.028000 C 21:15:33 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:15:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 21:15:33 Integrated Voltage Measurement... 21:15:52 Voltage Offset Correction: v_off_ini = 0.000002563 V, v_off_fin = 0.000007165 V 21:15:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175434212 Vs 21:15:53 Integrated Voltage Measurement... 21:16:12 Voltage Offset Correction: v_off_ini = 0.000006355 V, v_off_fin = -0.000000200 V 21:16:12 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300636 Vs 21:16:15 Temperature Measurement, Probe Number = 0, T = 20.275000 C 21:16:16 Temperature Measurement, Probe Number = 1, T = 20.058000 C 21:16:16 Temperature Measurement, Probe Number = 2, T = 20.025000 C 21:16:17 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:16:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 21:16:17 Integrated Voltage Measurement... 21:16:36 Voltage Offset Correction: v_off_ini = 0.000002949 V, v_off_fin = 0.000006973 V 21:16:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175434031 Vs 21:16:37 Integrated Voltage Measurement... 21:16:56 Voltage Offset Correction: v_off_ini = 0.000006206 V, v_off_fin = -0.000000505 V 21:16:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299527 Vs 21:46:59 Temperature Measurement, Probe Number = 0, T = 20.104000 C 21:47:00 Temperature Measurement, Probe Number = 1, T = 20.053000 C 21:47:01 Temperature Measurement, Probe Number = 2, T = 20.019000 C 21:47:01 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:47:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:47:01 Integrated Voltage Measurement... 21:47:21 Voltage Offset Correction: v_off_ini = 0.000005335 V, v_off_fin = 0.000007458 V 21:47:21 Integrated Voltage Measurement Delta Gap = 0.0040025 m VT = 0.175527466 Vs 21:47:22 Integrated Voltage Measurement... 21:47:42 Voltage Offset Correction: v_off_ini = 0.000006912 V, v_off_fin = 0.000001278 V 21:47:42 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175296766 Vs 21:47:45 Temperature Measurement, Probe Number = 0, T = 20.166000 C 21:47:45 Temperature Measurement, Probe Number = 1, T = 20.055000 C 21:47:46 Temperature Measurement, Probe Number = 2, T = 20.023000 C 21:47:47 Temperature Measurement, Probe Number = 3, T = 19.994000 C 21:47:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:47:47 Integrated Voltage Measurement... 21:48:07 Voltage Offset Correction: v_off_ini = 0.000003120 V, v_off_fin = 0.000007225 V 21:48:07 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175438557 Vs 21:48:07 Integrated Voltage Measurement... 21:48:28 Voltage Offset Correction: v_off_ini = 0.000006701 V, v_off_fin = 0.000001906 V 21:48:28 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175288603 Vs 21:48:31 Temperature Measurement, Probe Number = 0, T = 20.174000 C 21:48:32 Temperature Measurement, Probe Number = 1, T = 20.056000 C 21:48:32 Temperature Measurement, Probe Number = 2, T = 20.023000 C 21:48:33 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:48:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:48:33 Integrated Voltage Measurement... 21:48:52 Voltage Offset Correction: v_off_ini = 0.000003173 V, v_off_fin = 0.000007821 V 21:48:53 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175430016 Vs 21:48:53 Integrated Voltage Measurement... 21:49:12 Voltage Offset Correction: v_off_ini = 0.000006632 V, v_off_fin = 0.000000104 V 21:49:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296931 Vs 21:49:15 Temperature Measurement, Probe Number = 0, T = 20.162000 C 21:49:16 Temperature Measurement, Probe Number = 1, T = 20.054000 C 21:49:16 Temperature Measurement, Probe Number = 2, T = 20.023000 C 21:49:17 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:49:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:49:17 Integrated Voltage Measurement... 21:49:36 Voltage Offset Correction: v_off_ini = 0.000002491 V, v_off_fin = 0.000007324 V 21:49:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445772 Vs 21:49:37 Integrated Voltage Measurement... 21:49:56 Voltage Offset Correction: v_off_ini = 0.000006290 V, v_off_fin = 0.000000274 V 21:49:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175302803 Vs 21:49:59 Temperature Measurement, Probe Number = 0, T = 20.140000 C 21:50:00 Temperature Measurement, Probe Number = 1, T = 20.053000 C 21:50:01 Temperature Measurement, Probe Number = 2, T = 20.024000 C 21:50:01 Temperature Measurement, Probe Number = 3, T = 19.994000 C 21:50:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:50:02 Integrated Voltage Measurement... 21:50:21 Voltage Offset Correction: v_off_ini = 0.000002959 V, v_off_fin = 0.000007165 V 21:50:22 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175440500 Vs 21:50:22 Integrated Voltage Measurement... 21:50:41 Voltage Offset Correction: v_off_ini = 0.000006162 V, v_off_fin = -0.000000252 V 21:50:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175302104 Vs 21:50:44 Temperature Measurement, Probe Number = 0, T = 20.101000 C 21:50:45 Temperature Measurement, Probe Number = 1, T = 20.052000 C 21:50:46 Temperature Measurement, Probe Number = 2, T = 20.017000 C 21:50:46 Temperature Measurement, Probe Number = 3, T = 19.989000 C 21:50:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:50:46 Integrated Voltage Measurement... 21:51:05 Voltage Offset Correction: v_off_ini = 0.000002738 V, v_off_fin = 0.000007704 V 21:51:06 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175446425 Vs 21:51:06 Integrated Voltage Measurement... 21:51:25 Voltage Offset Correction: v_off_ini = 0.000006510 V, v_off_fin = 0.000000519 V 21:51:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301540 Vs 21:51:28 Temperature Measurement, Probe Number = 0, T = 20.127000 C 21:51:29 Temperature Measurement, Probe Number = 1, T = 20.052000 C 21:51:30 Temperature Measurement, Probe Number = 2, T = 20.019000 C 21:51:30 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:51:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:51:30 Integrated Voltage Measurement... 21:51:49 Voltage Offset Correction: v_off_ini = 0.000003290 V, v_off_fin = 0.000007924 V 21:51:49 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175451871 Vs 21:51:50 Integrated Voltage Measurement... 21:52:09 Voltage Offset Correction: v_off_ini = 0.000006707 V, v_off_fin = 0.000000322 V 21:52:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299799 Vs 21:52:12 Temperature Measurement, Probe Number = 0, T = 20.169000 C 21:52:12 Temperature Measurement, Probe Number = 1, T = 20.054000 C 21:52:13 Temperature Measurement, Probe Number = 2, T = 20.019000 C 21:52:14 Temperature Measurement, Probe Number = 3, T = 19.992000 C 21:52:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:52:14 Integrated Voltage Measurement... 21:52:33 Voltage Offset Correction: v_off_ini = 0.000003062 V, v_off_fin = 0.000008303 V 21:52:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453892 Vs 21:52:33 Integrated Voltage Measurement... 21:52:52 Voltage Offset Correction: v_off_ini = 0.000007700 V, v_off_fin = 0.000000830 V 21:52:53 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175292623 Vs 21:52:55 Temperature Measurement, Probe Number = 0, T = 20.163000 C 21:52:56 Temperature Measurement, Probe Number = 1, T = 20.052000 C 21:52:57 Temperature Measurement, Probe Number = 2, T = 20.020000 C 21:52:57 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:52:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:52:57 Integrated Voltage Measurement... 21:53:17 Voltage Offset Correction: v_off_ini = 0.000003390 V, v_off_fin = 0.000007601 V 21:53:17 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175447996 Vs 21:53:17 Integrated Voltage Measurement... 21:53:36 Voltage Offset Correction: v_off_ini = 0.000006673 V, v_off_fin = 0.000000037 V 21:53:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175303073 Vs 21:53:39 Temperature Measurement, Probe Number = 0, T = 20.241000 C 21:53:40 Temperature Measurement, Probe Number = 1, T = 20.052000 C 21:53:41 Temperature Measurement, Probe Number = 2, T = 20.020000 C 21:53:42 Temperature Measurement, Probe Number = 3, T = 19.991000 C 21:53:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 21:53:42 Integrated Voltage Measurement... 21:54:01 Voltage Offset Correction: v_off_ini = 0.000002484 V, v_off_fin = 0.000008031 V 21:54:01 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175448950 Vs 21:54:01 Integrated Voltage Measurement... 21:54:21 Voltage Offset Correction: v_off_ini = 0.000007088 V, v_off_fin = 0.000000052 V 21:54:21 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297431 Vs 22:24:24 Temperature Measurement, Probe Number = 0, T = 20.175000 C 22:24:25 Temperature Measurement, Probe Number = 1, T = 20.041000 C 22:24:25 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:24:26 Temperature Measurement, Probe Number = 3, T = 19.980000 C 22:24:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:24:26 Integrated Voltage Measurement... 22:24:46 Voltage Offset Correction: v_off_ini = 0.000005082 V, v_off_fin = 0.000007384 V 22:24:46 Integrated Voltage Measurement Delta Gap = 0.0040025 m VT = 0.175526564 Vs 22:24:46 Integrated Voltage Measurement... 22:25:06 Voltage Offset Correction: v_off_ini = 0.000006503 V, v_off_fin = -0.000000132 V 22:25:06 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175295736 Vs 22:25:09 Temperature Measurement, Probe Number = 0, T = 20.128000 C 22:25:09 Temperature Measurement, Probe Number = 1, T = 20.042000 C 22:25:10 Temperature Measurement, Probe Number = 2, T = 20.006000 C 22:25:11 Temperature Measurement, Probe Number = 3, T = 19.981000 C 22:25:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 22:25:11 Integrated Voltage Measurement... 22:25:30 Voltage Offset Correction: v_off_ini = 0.000003271 V, v_off_fin = 0.000007184 V 22:25:30 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175448287 Vs 22:25:30 Integrated Voltage Measurement... 22:25:50 Voltage Offset Correction: v_off_ini = 0.000006426 V, v_off_fin = 0.000000593 V 22:25:50 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175296878 Vs 22:25:53 Temperature Measurement, Probe Number = 0, T = 20.080000 C 22:25:54 Temperature Measurement, Probe Number = 1, T = 20.042000 C 22:25:54 Temperature Measurement, Probe Number = 2, T = 20.009000 C 22:25:55 Temperature Measurement, Probe Number = 3, T = 19.985000 C 22:25:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 22:25:55 Integrated Voltage Measurement... 22:26:15 Voltage Offset Correction: v_off_ini = 0.000003471 V, v_off_fin = 0.000006943 V 22:26:15 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175454053 Vs 22:26:15 Integrated Voltage Measurement... 22:26:35 Voltage Offset Correction: v_off_ini = 0.000006041 V, v_off_fin = 0.000000442 V 22:26:35 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175301895 Vs 22:26:38 Temperature Measurement, Probe Number = 0, T = 20.096000 C 22:26:38 Temperature Measurement, Probe Number = 1, T = 20.045000 C 22:26:39 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:26:40 Temperature Measurement, Probe Number = 3, T = 19.983000 C 22:26:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:26:40 Integrated Voltage Measurement... 22:26:59 Voltage Offset Correction: v_off_ini = 0.000003133 V, v_off_fin = 0.000008262 V 22:26:59 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175451873 Vs 22:26:59 Integrated Voltage Measurement... 22:27:19 Voltage Offset Correction: v_off_ini = 0.000007413 V, v_off_fin = 0.000001120 V 22:27:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175291070 Vs 22:27:22 Temperature Measurement, Probe Number = 0, T = 20.036000 C 22:27:22 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:27:23 Temperature Measurement, Probe Number = 2, T = 20.006000 C 22:27:24 Temperature Measurement, Probe Number = 3, T = 19.980000 C 22:27:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 22:27:24 Integrated Voltage Measurement... 22:27:43 Voltage Offset Correction: v_off_ini = 0.000004458 V, v_off_fin = 0.000007665 V 22:27:44 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175452821 Vs 22:27:44 Integrated Voltage Measurement... 22:28:03 Voltage Offset Correction: v_off_ini = 0.000006583 V, v_off_fin = -0.000000293 V 22:28:03 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300642 Vs 22:28:06 Temperature Measurement, Probe Number = 0, T = 20.005000 C 22:28:07 Temperature Measurement, Probe Number = 1, T = 20.042000 C 22:28:07 Temperature Measurement, Probe Number = 2, T = 20.004000 C 22:28:08 Temperature Measurement, Probe Number = 3, T = 19.981000 C 22:28:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:28:08 Integrated Voltage Measurement... 22:28:27 Voltage Offset Correction: v_off_ini = 0.000003179 V, v_off_fin = 0.000007662 V 22:28:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453328 Vs 22:28:28 Integrated Voltage Measurement... 22:28:47 Voltage Offset Correction: v_off_ini = 0.000006685 V, v_off_fin = 0.000000092 V 22:28:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311805 Vs 22:28:50 Temperature Measurement, Probe Number = 0, T = 20.011000 C 22:28:51 Temperature Measurement, Probe Number = 1, T = 20.044000 C 22:28:51 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:28:52 Temperature Measurement, Probe Number = 3, T = 19.983000 C 22:28:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.01 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:28:52 Integrated Voltage Measurement... 22:29:12 Voltage Offset Correction: v_off_ini = 0.000003229 V, v_off_fin = 0.000007326 V 22:29:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175454622 Vs 22:29:13 Integrated Voltage Measurement... 22:29:32 Voltage Offset Correction: v_off_ini = 0.000006260 V, v_off_fin = -0.000000006 V 22:29:32 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175301843 Vs 22:29:35 Temperature Measurement, Probe Number = 0, T = 20.026000 C 22:29:36 Temperature Measurement, Probe Number = 1, T = 20.041000 C 22:29:36 Temperature Measurement, Probe Number = 2, T = 20.006000 C 22:29:37 Temperature Measurement, Probe Number = 3, T = 19.983000 C 22:29:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 22:29:37 Integrated Voltage Measurement... 22:29:56 Voltage Offset Correction: v_off_ini = 0.000002836 V, v_off_fin = 0.000007871 V 22:29:57 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175454753 Vs 22:29:57 Integrated Voltage Measurement... 22:30:16 Voltage Offset Correction: v_off_ini = 0.000007010 V, v_off_fin = -0.000000169 V 22:30:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307785 Vs 22:30:19 Temperature Measurement, Probe Number = 0, T = 19.992000 C 22:30:20 Temperature Measurement, Probe Number = 1, T = 20.041000 C 22:30:20 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:30:21 Temperature Measurement, Probe Number = 3, T = 19.983000 C 22:30:21 Magnet Test Parameter Measurements P0 = Room, Value = 19.99 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:30:21 Integrated Voltage Measurement... 22:30:40 Voltage Offset Correction: v_off_ini = 0.000002919 V, v_off_fin = 0.000007378 V 22:30:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175459299 Vs 22:30:41 Integrated Voltage Measurement... 22:31:00 Voltage Offset Correction: v_off_ini = 0.000006744 V, v_off_fin = 0.000000117 V 22:31:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175302764 Vs 22:31:03 Temperature Measurement, Probe Number = 0, T = 19.895000 C 22:31:04 Temperature Measurement, Probe Number = 1, T = 20.040000 C 22:31:05 Temperature Measurement, Probe Number = 2, T = 20.004000 C 22:31:05 Temperature Measurement, Probe Number = 3, T = 19.978000 C 22:31:05 Magnet Test Parameter Measurements P0 = Room, Value = 19.89 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:31:05 Integrated Voltage Measurement... 22:31:25 Voltage Offset Correction: v_off_ini = 0.000003056 V, v_off_fin = 0.000007262 V 22:31:25 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175447940 Vs 22:31:25 Integrated Voltage Measurement... 22:31:44 Voltage Offset Correction: v_off_ini = 0.000006371 V, v_off_fin = -0.000001122 V 22:31:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308637 Vs 23:01:47 Temperature Measurement, Probe Number = 0, T = 19.910000 C 23:01:48 Temperature Measurement, Probe Number = 1, T = 20.025000 C 23:01:49 Temperature Measurement, Probe Number = 2, T = 19.992000 C 23:01:49 Temperature Measurement, Probe Number = 3, T = 19.970000 C 23:01:49 Magnet Test Parameter Measurements P0 = Room, Value = 19.91 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:01:49 Integrated Voltage Measurement... 23:02:09 Voltage Offset Correction: v_off_ini = 0.000005250 V, v_off_fin = 0.000007565 V 23:02:09 Integrated Voltage Measurement Delta Gap = 0.0040025 m VT = 0.175539631 Vs 23:02:09 Integrated Voltage Measurement... 23:02:29 Voltage Offset Correction: v_off_ini = 0.000006713 V, v_off_fin = -0.000000156 V 23:02:29 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175311194 Vs 23:02:32 Temperature Measurement, Probe Number = 0, T = 19.917000 C 23:02:33 Temperature Measurement, Probe Number = 1, T = 20.026000 C 23:02:33 Temperature Measurement, Probe Number = 2, T = 19.992000 C 23:02:34 Temperature Measurement, Probe Number = 3, T = 19.971000 C 23:02:34 Magnet Test Parameter Measurements P0 = Room, Value = 19.92 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:02:34 Integrated Voltage Measurement... 23:02:54 Voltage Offset Correction: v_off_ini = 0.000003537 V, v_off_fin = 0.000007597 V 23:02:54 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175451526 Vs 23:02:54 Integrated Voltage Measurement... 23:03:13 Voltage Offset Correction: v_off_ini = 0.000006677 V, v_off_fin = 0.000000216 V 23:03:13 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175297973 Vs 23:03:16 Temperature Measurement, Probe Number = 0, T = 19.914000 C 23:03:17 Temperature Measurement, Probe Number = 1, T = 20.027000 C 23:03:18 Temperature Measurement, Probe Number = 2, T = 19.991000 C 23:03:18 Temperature Measurement, Probe Number = 3, T = 19.970000 C 23:03:18 Magnet Test Parameter Measurements P0 = Room, Value = 19.91 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:03:18 Integrated Voltage Measurement... 23:03:38 Voltage Offset Correction: v_off_ini = 0.000003181 V, v_off_fin = 0.000007704 V 23:03:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175455631 Vs 23:03:38 Integrated Voltage Measurement... 23:03:57 Voltage Offset Correction: v_off_ini = 0.000006411 V, v_off_fin = -0.000000535 V 23:03:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175298256 Vs 23:04:00 Temperature Measurement, Probe Number = 0, T = 19.871000 C 23:04:01 Temperature Measurement, Probe Number = 1, T = 20.029000 C 23:04:02 Temperature Measurement, Probe Number = 2, T = 19.991000 C 23:04:02 Temperature Measurement, Probe Number = 3, T = 19.968000 C 23:04:02 Magnet Test Parameter Measurements P0 = Room, Value = 19.87 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:04:03 Integrated Voltage Measurement... 23:04:21 Voltage Offset Correction: v_off_ini = 0.000002763 V, v_off_fin = 0.000007326 V 23:04:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175457122 Vs 23:04:22 Integrated Voltage Measurement... 23:04:41 Voltage Offset Correction: v_off_ini = 0.000006532 V, v_off_fin = 0.000000624 V 23:04:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317376 Vs 23:04:44 Temperature Measurement, Probe Number = 0, T = 19.893000 C 23:04:45 Temperature Measurement, Probe Number = 1, T = 20.024000 C 23:04:45 Temperature Measurement, Probe Number = 2, T = 19.989000 C 23:04:46 Temperature Measurement, Probe Number = 3, T = 19.967000 C 23:04:46 Magnet Test Parameter Measurements P0 = Room, Value = 19.89 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:04:46 Integrated Voltage Measurement... 23:05:05 Voltage Offset Correction: v_off_ini = 0.000002994 V, v_off_fin = 0.000007204 V 23:05:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175462665 Vs 23:05:06 Integrated Voltage Measurement... 23:05:25 Voltage Offset Correction: v_off_ini = 0.000006555 V, v_off_fin = 0.000000737 V 23:05:26 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175302905 Vs 23:05:28 Temperature Measurement, Probe Number = 0, T = 19.898000 C 23:05:29 Temperature Measurement, Probe Number = 1, T = 20.024000 C 23:05:30 Temperature Measurement, Probe Number = 2, T = 19.988000 C 23:05:30 Temperature Measurement, Probe Number = 3, T = 19.967000 C 23:05:30 Magnet Test Parameter Measurements P0 = Room, Value = 19.90 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:05:31 Integrated Voltage Measurement... 23:05:51 Voltage Offset Correction: v_off_ini = 0.000003127 V, v_off_fin = 0.000007255 V 23:05:51 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175455904 Vs 23:05:51 Integrated Voltage Measurement... 23:06:10 Voltage Offset Correction: v_off_ini = 0.000006744 V, v_off_fin = 0.000000125 V 23:06:10 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175306627 Vs 23:06:13 Temperature Measurement, Probe Number = 0, T = 19.924000 C 23:06:14 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:06:15 Temperature Measurement, Probe Number = 2, T = 19.982000 C 23:06:15 Temperature Measurement, Probe Number = 3, T = 19.966000 C 23:06:15 Magnet Test Parameter Measurements P0 = Room, Value = 19.92 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:06:15 Integrated Voltage Measurement... 23:06:35 Voltage Offset Correction: v_off_ini = 0.000003039 V, v_off_fin = 0.000007830 V 23:06:35 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175453990 Vs 23:06:35 Integrated Voltage Measurement... 23:06:54 Voltage Offset Correction: v_off_ini = 0.000007227 V, v_off_fin = 0.000000898 V 23:06:55 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300447 Vs 23:06:57 Temperature Measurement, Probe Number = 0, T = 19.848000 C 23:06:58 Temperature Measurement, Probe Number = 1, T = 20.025000 C 23:06:59 Temperature Measurement, Probe Number = 2, T = 19.985000 C 23:06:59 Temperature Measurement, Probe Number = 3, T = 19.964000 C 23:06:59 Magnet Test Parameter Measurements P0 = Room, Value = 19.85 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:06:59 Integrated Voltage Measurement... 23:07:18 Voltage Offset Correction: v_off_ini = 0.000002607 V, v_off_fin = 0.000007399 V 23:07:19 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175450355 Vs 23:07:19 Integrated Voltage Measurement... 23:07:38 Voltage Offset Correction: v_off_ini = 0.000006323 V, v_off_fin = 0.000000127 V 23:07:38 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304084 Vs 23:07:41 Temperature Measurement, Probe Number = 0, T = 19.863000 C 23:07:41 Temperature Measurement, Probe Number = 1, T = 20.026000 C 23:07:42 Temperature Measurement, Probe Number = 2, T = 19.987000 C 23:07:43 Temperature Measurement, Probe Number = 3, T = 19.972000 C 23:07:43 Magnet Test Parameter Measurements P0 = Room, Value = 19.86 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:07:43 Integrated Voltage Measurement... 23:08:02 Voltage Offset Correction: v_off_ini = 0.000002315 V, v_off_fin = 0.000007648 V 23:08:03 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175463672 Vs 23:08:03 Integrated Voltage Measurement... 23:08:22 Voltage Offset Correction: v_off_ini = 0.000006742 V, v_off_fin = 0.000000241 V 23:08:22 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175298820 Vs 23:08:25 Temperature Measurement, Probe Number = 0, T = 19.896000 C 23:08:25 Temperature Measurement, Probe Number = 1, T = 20.026000 C 23:08:26 Temperature Measurement, Probe Number = 2, T = 19.989000 C 23:08:27 Temperature Measurement, Probe Number = 3, T = 19.970000 C 23:08:27 Magnet Test Parameter Measurements P0 = Room, Value = 19.90 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:08:27 Integrated Voltage Measurement... 23:08:47 Voltage Offset Correction: v_off_ini = 0.000003230 V, v_off_fin = 0.000007065 V 23:08:47 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175463837 Vs 23:08:47 Integrated Voltage Measurement... 23:09:07 Voltage Offset Correction: v_off_ini = 0.000006131 V, v_off_fin = 0.000000251 V 23:09:07 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175313563 Vs 23:39:10 Temperature Measurement, Probe Number = 0, T = 20.099000 C 23:39:10 Temperature Measurement, Probe Number = 1, T = 20.018000 C 23:39:11 Temperature Measurement, Probe Number = 2, T = 19.981000 C 23:39:12 Temperature Measurement, Probe Number = 3, T = 19.962000 C 23:39:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:39:12 Integrated Voltage Measurement... 23:39:31 Voltage Offset Correction: v_off_ini = 0.000005581 V, v_off_fin = 0.000007930 V 23:39:31 Integrated Voltage Measurement Delta Gap = 0.0040026 m VT = 0.175550295 Vs 23:39:32 Integrated Voltage Measurement... 23:39:51 Voltage Offset Correction: v_off_ini = 0.000006976 V, v_off_fin = 0.000000095 V 23:39:51 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294502 Vs 23:39:54 Temperature Measurement, Probe Number = 0, T = 20.103000 C 23:39:54 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:39:55 Temperature Measurement, Probe Number = 2, T = 19.985000 C 23:39:56 Temperature Measurement, Probe Number = 3, T = 19.966000 C 23:39:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:39:56 Integrated Voltage Measurement... 23:40:15 Voltage Offset Correction: v_off_ini = 0.000003276 V, v_off_fin = 0.000007432 V 23:40:15 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453921 Vs 23:40:15 Integrated Voltage Measurement... 23:40:35 Voltage Offset Correction: v_off_ini = 0.000006633 V, v_off_fin = 0.000000156 V 23:40:35 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175303162 Vs 23:40:38 Temperature Measurement, Probe Number = 0, T = 20.092000 C 23:40:38 Temperature Measurement, Probe Number = 1, T = 20.025000 C 23:40:39 Temperature Measurement, Probe Number = 2, T = 19.989000 C 23:40:40 Temperature Measurement, Probe Number = 3, T = 19.968000 C 23:40:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:40:40 Integrated Voltage Measurement... 23:41:00 Voltage Offset Correction: v_off_ini = 0.000003729 V, v_off_fin = 0.000007459 V 23:41:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175457514 Vs 23:41:00 Integrated Voltage Measurement... 23:41:19 Voltage Offset Correction: v_off_ini = 0.000006742 V, v_off_fin = 0.000000155 V 23:41:20 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175294648 Vs 23:41:22 Temperature Measurement, Probe Number = 0, T = 20.129000 C 23:41:23 Temperature Measurement, Probe Number = 1, T = 20.022000 C 23:41:24 Temperature Measurement, Probe Number = 2, T = 19.988000 C 23:41:24 Temperature Measurement, Probe Number = 3, T = 19.965000 C 23:41:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 23:41:25 Integrated Voltage Measurement... 23:41:44 Voltage Offset Correction: v_off_ini = 0.000003364 V, v_off_fin = 0.000007158 V 23:41:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175452497 Vs 23:41:44 Integrated Voltage Measurement... 23:42:03 Voltage Offset Correction: v_off_ini = 0.000006804 V, v_off_fin = 0.000000559 V 23:42:04 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300018 Vs 23:42:06 Temperature Measurement, Probe Number = 0, T = 20.158000 C 23:42:07 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:42:08 Temperature Measurement, Probe Number = 2, T = 19.985000 C 23:42:08 Temperature Measurement, Probe Number = 3, T = 19.968000 C 23:42:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:42:08 Integrated Voltage Measurement... 23:42:28 Voltage Offset Correction: v_off_ini = 0.000002948 V, v_off_fin = 0.000007769 V 23:42:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175457306 Vs 23:42:28 Integrated Voltage Measurement... 23:42:47 Voltage Offset Correction: v_off_ini = 0.000006974 V, v_off_fin = -0.000000584 V 23:42:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312225 Vs 23:42:50 Temperature Measurement, Probe Number = 0, T = 20.164000 C 23:42:51 Temperature Measurement, Probe Number = 1, T = 20.019000 C 23:42:52 Temperature Measurement, Probe Number = 2, T = 19.984000 C 23:42:52 Temperature Measurement, Probe Number = 3, T = 19.964000 C 23:42:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:42:53 Integrated Voltage Measurement... 23:43:12 Voltage Offset Correction: v_off_ini = 0.000002348 V, v_off_fin = 0.000007303 V 23:43:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175451128 Vs 23:43:12 Integrated Voltage Measurement... 23:43:32 Voltage Offset Correction: v_off_ini = 0.000006101 V, v_off_fin = 0.000000185 V 23:43:33 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175316921 Vs 23:43:35 Temperature Measurement, Probe Number = 0, T = 20.174000 C 23:43:36 Temperature Measurement, Probe Number = 1, T = 20.018000 C 23:43:37 Temperature Measurement, Probe Number = 2, T = 19.982000 C 23:43:37 Temperature Measurement, Probe Number = 3, T = 19.964000 C 23:43:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:43:37 Integrated Voltage Measurement... 23:43:57 Voltage Offset Correction: v_off_ini = 0.000002755 V, v_off_fin = 0.000007446 V 23:43:57 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175441064 Vs 23:43:57 Integrated Voltage Measurement... 23:44:17 Voltage Offset Correction: v_off_ini = 0.000006779 V, v_off_fin = 0.000000162 V 23:44:17 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309971 Vs 23:44:20 Temperature Measurement, Probe Number = 0, T = 20.181000 C 23:44:21 Temperature Measurement, Probe Number = 1, T = 20.023000 C 23:44:21 Temperature Measurement, Probe Number = 2, T = 19.987000 C 23:44:22 Temperature Measurement, Probe Number = 3, T = 19.965000 C 23:44:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 23:44:22 Integrated Voltage Measurement... 23:44:41 Voltage Offset Correction: v_off_ini = 0.000002858 V, v_off_fin = 0.000007263 V 23:44:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175447707 Vs 23:44:41 Integrated Voltage Measurement... 23:45:01 Voltage Offset Correction: v_off_ini = 0.000006570 V, v_off_fin = -0.000000183 V 23:45:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310021 Vs 23:45:04 Temperature Measurement, Probe Number = 0, T = 20.183000 C 23:45:04 Temperature Measurement, Probe Number = 1, T = 20.024000 C 23:45:05 Temperature Measurement, Probe Number = 2, T = 19.986000 C 23:45:06 Temperature Measurement, Probe Number = 3, T = 19.967000 C 23:45:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:45:06 Integrated Voltage Measurement... 23:45:25 Voltage Offset Correction: v_off_ini = 0.000002659 V, v_off_fin = 0.000007320 V 23:45:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175447019 Vs 23:45:25 Integrated Voltage Measurement... 23:45:44 Voltage Offset Correction: v_off_ini = 0.000006430 V, v_off_fin = -0.000000699 V 23:45:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305609 Vs 23:45:47 Temperature Measurement, Probe Number = 0, T = 20.206000 C 23:45:48 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:45:48 Temperature Measurement, Probe Number = 2, T = 19.987000 C 23:45:49 Temperature Measurement, Probe Number = 3, T = 19.965000 C 23:45:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 23:45:49 Integrated Voltage Measurement... 23:46:08 Voltage Offset Correction: v_off_ini = 0.000002812 V, v_off_fin = 0.000007339 V 23:46:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175448666 Vs 23:46:09 Integrated Voltage Measurement... 23:46:28 Voltage Offset Correction: v_off_ini = 0.000006417 V, v_off_fin = -0.000000212 V 23:46:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311623 Vs 00:16:31 Temperature Measurement, Probe Number = 0, T = 20.067000 C 00:16:32 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:16:32 Temperature Measurement, Probe Number = 2, T = 19.975000 C 00:16:33 Temperature Measurement, Probe Number = 3, T = 19.959000 C 00:16:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:16:33 Integrated Voltage Measurement... 00:16:53 Voltage Offset Correction: v_off_ini = 0.000004565 V, v_off_fin = 0.000007058 V 00:16:53 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175539599 Vs 00:16:53 Integrated Voltage Measurement... 00:17:12 Voltage Offset Correction: v_off_ini = 0.000006223 V, v_off_fin = -0.000000303 V 00:17:12 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175303346 Vs 00:17:15 Temperature Measurement, Probe Number = 0, T = 20.059000 C 00:17:16 Temperature Measurement, Probe Number = 1, T = 20.010000 C 00:17:17 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:17:17 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:17:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:17:17 Integrated Voltage Measurement... 00:17:37 Voltage Offset Correction: v_off_ini = 0.000002343 V, v_off_fin = 0.000006589 V 00:17:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175442363 Vs 00:17:37 Integrated Voltage Measurement... 00:17:57 Voltage Offset Correction: v_off_ini = 0.000006153 V, v_off_fin = -0.000000125 V 00:17:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175308224 Vs 00:18:00 Temperature Measurement, Probe Number = 0, T = 20.019000 C 00:18:00 Temperature Measurement, Probe Number = 1, T = 20.010000 C 00:18:01 Temperature Measurement, Probe Number = 2, T = 19.974000 C 00:18:02 Temperature Measurement, Probe Number = 3, T = 19.957000 C 00:18:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.02 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 00:18:02 Integrated Voltage Measurement... 00:18:22 Voltage Offset Correction: v_off_ini = 0.000002718 V, v_off_fin = 0.000007034 V 00:18:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175443388 Vs 00:18:22 Integrated Voltage Measurement... 00:18:42 Voltage Offset Correction: v_off_ini = 0.000006178 V, v_off_fin = -0.000000247 V 00:18:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175307860 Vs 00:18:45 Temperature Measurement, Probe Number = 0, T = 20.005000 C 00:18:45 Temperature Measurement, Probe Number = 1, T = 20.011000 C 00:18:46 Temperature Measurement, Probe Number = 2, T = 19.974000 C 00:18:47 Temperature Measurement, Probe Number = 3, T = 19.957000 C 00:18:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 00:18:47 Integrated Voltage Measurement... 00:19:06 Voltage Offset Correction: v_off_ini = 0.000002818 V, v_off_fin = 0.000007171 V 00:19:06 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175448055 Vs 00:19:07 Integrated Voltage Measurement... 00:19:26 Voltage Offset Correction: v_off_ini = 0.000005997 V, v_off_fin = -0.000000229 V 00:19:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175305823 Vs 00:19:29 Temperature Measurement, Probe Number = 0, T = 20.037000 C 00:19:29 Temperature Measurement, Probe Number = 1, T = 20.013000 C 00:19:30 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:19:31 Temperature Measurement, Probe Number = 3, T = 19.959000 C 00:19:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:19:31 Integrated Voltage Measurement... 00:19:50 Voltage Offset Correction: v_off_ini = 0.000003132 V, v_off_fin = 0.000007531 V 00:19:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444545 Vs 00:19:50 Integrated Voltage Measurement... 00:20:09 Voltage Offset Correction: v_off_ini = 0.000006525 V, v_off_fin = -0.000000189 V 00:20:10 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296244 Vs 00:20:12 Temperature Measurement, Probe Number = 0, T = 20.092000 C 00:20:13 Temperature Measurement, Probe Number = 1, T = 20.011000 C 00:20:14 Temperature Measurement, Probe Number = 2, T = 19.979000 C 00:20:14 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:20:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:20:14 Integrated Voltage Measurement... 00:20:34 Voltage Offset Correction: v_off_ini = 0.000003105 V, v_off_fin = 0.000006755 V 00:20:34 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175445176 Vs 00:20:34 Integrated Voltage Measurement... 00:20:53 Voltage Offset Correction: v_off_ini = 0.000006401 V, v_off_fin = -0.000000141 V 00:20:54 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175307243 Vs 00:20:56 Temperature Measurement, Probe Number = 0, T = 20.108000 C 00:20:57 Temperature Measurement, Probe Number = 1, T = 20.011000 C 00:20:58 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:20:58 Temperature Measurement, Probe Number = 3, T = 19.959000 C 00:20:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:20:58 Integrated Voltage Measurement... 00:21:18 Voltage Offset Correction: v_off_ini = 0.000002437 V, v_off_fin = 0.000007490 V 00:21:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175451476 Vs 00:21:19 Integrated Voltage Measurement... 00:21:38 Voltage Offset Correction: v_off_ini = 0.000006810 V, v_off_fin = -0.000000324 V 00:21:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175307947 Vs 00:21:41 Temperature Measurement, Probe Number = 0, T = 20.130000 C 00:21:42 Temperature Measurement, Probe Number = 1, T = 20.011000 C 00:21:42 Temperature Measurement, Probe Number = 2, T = 19.980000 C 00:21:43 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:21:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:21:43 Integrated Voltage Measurement... 00:22:02 Voltage Offset Correction: v_off_ini = 0.000002748 V, v_off_fin = 0.000007648 V 00:22:03 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175444893 Vs 00:22:03 Integrated Voltage Measurement... 00:22:22 Voltage Offset Correction: v_off_ini = 0.000006859 V, v_off_fin = 0.000000194 V 00:22:22 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175306377 Vs 00:22:25 Temperature Measurement, Probe Number = 0, T = 20.089000 C 00:22:26 Temperature Measurement, Probe Number = 1, T = 20.013000 C 00:22:26 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:22:27 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:22:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:22:27 Integrated Voltage Measurement... 00:22:47 Voltage Offset Correction: v_off_ini = 0.000002973 V, v_off_fin = 0.000007825 V 00:22:47 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175450460 Vs 00:22:47 Integrated Voltage Measurement... 00:23:06 Voltage Offset Correction: v_off_ini = 0.000006533 V, v_off_fin = 0.000000050 V 00:23:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307870 Vs 00:23:09 Temperature Measurement, Probe Number = 0, T = 20.121000 C 00:23:10 Temperature Measurement, Probe Number = 1, T = 20.012000 C 00:23:11 Temperature Measurement, Probe Number = 2, T = 19.982000 C 00:23:11 Temperature Measurement, Probe Number = 3, T = 19.962000 C 00:23:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:23:11 Integrated Voltage Measurement... 00:23:30 Voltage Offset Correction: v_off_ini = 0.000003420 V, v_off_fin = 0.000008000 V 00:23:31 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175452628 Vs 00:23:31 Integrated Voltage Measurement... 00:23:50 Voltage Offset Correction: v_off_ini = 0.000006707 V, v_off_fin = -0.000000459 V 00:23:51 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175312451 Vs 00:53:53 Temperature Measurement, Probe Number = 0, T = 20.165000 C 00:53:54 Temperature Measurement, Probe Number = 1, T = 20.012000 C 00:53:55 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:53:56 Temperature Measurement, Probe Number = 3, T = 19.962000 C 00:53:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:53:56 Integrated Voltage Measurement... 00:54:15 Voltage Offset Correction: v_off_ini = 0.000004857 V, v_off_fin = 0.000007412 V 00:54:15 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175548471 Vs 00:54:16 Integrated Voltage Measurement... 00:54:35 Voltage Offset Correction: v_off_ini = 0.000006156 V, v_off_fin = -0.000000232 V 00:54:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286322 Vs 00:54:38 Temperature Measurement, Probe Number = 0, T = 20.235000 C 00:54:38 Temperature Measurement, Probe Number = 1, T = 20.016000 C 00:54:39 Temperature Measurement, Probe Number = 2, T = 19.985000 C 00:54:39 Temperature Measurement, Probe Number = 3, T = 19.963000 C 00:54:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:54:40 Integrated Voltage Measurement... 00:54:59 Voltage Offset Correction: v_off_ini = 0.000002675 V, v_off_fin = 0.000006716 V 00:54:59 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430660 Vs 00:54:59 Integrated Voltage Measurement... 00:55:19 Voltage Offset Correction: v_off_ini = 0.000006021 V, v_off_fin = -0.000000128 V 00:55:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293244 Vs 00:55:21 Temperature Measurement, Probe Number = 0, T = 20.279000 C 00:55:22 Temperature Measurement, Probe Number = 1, T = 20.012000 C 00:55:23 Temperature Measurement, Probe Number = 2, T = 19.984000 C 00:55:23 Temperature Measurement, Probe Number = 3, T = 19.961000 C 00:55:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:55:24 Integrated Voltage Measurement... 00:55:43 Voltage Offset Correction: v_off_ini = 0.000002242 V, v_off_fin = 0.000007466 V 00:55:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175430012 Vs 00:55:43 Integrated Voltage Measurement... 00:56:02 Voltage Offset Correction: v_off_ini = 0.000006793 V, v_off_fin = 0.000000081 V 00:56:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175295753 Vs 00:56:05 Temperature Measurement, Probe Number = 0, T = 20.329000 C 00:56:06 Temperature Measurement, Probe Number = 1, T = 20.013000 C 00:56:06 Temperature Measurement, Probe Number = 2, T = 19.984000 C 00:56:07 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:56:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:56:07 Integrated Voltage Measurement... 00:56:26 Voltage Offset Correction: v_off_ini = 0.000002803 V, v_off_fin = 0.000006626 V 00:56:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428902 Vs 00:56:27 Integrated Voltage Measurement... 00:56:46 Voltage Offset Correction: v_off_ini = 0.000005902 V, v_off_fin = -0.000000034 V 00:56:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285642 Vs 00:56:49 Temperature Measurement, Probe Number = 0, T = 20.354000 C 00:56:49 Temperature Measurement, Probe Number = 1, T = 20.014000 C 00:56:50 Temperature Measurement, Probe Number = 2, T = 19.984000 C 00:56:51 Temperature Measurement, Probe Number = 3, T = 19.964000 C 00:56:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:56:51 Integrated Voltage Measurement... 00:57:11 Voltage Offset Correction: v_off_ini = 0.000003097 V, v_off_fin = 0.000007169 V 00:57:11 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175430947 Vs 00:57:11 Integrated Voltage Measurement... 00:57:30 Voltage Offset Correction: v_off_ini = 0.000006098 V, v_off_fin = -0.000000504 V 00:57:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175291197 Vs 00:57:33 Temperature Measurement, Probe Number = 0, T = 20.329000 C 00:57:34 Temperature Measurement, Probe Number = 1, T = 20.013000 C 00:57:35 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:57:35 Temperature Measurement, Probe Number = 3, T = 19.961000 C 00:57:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:57:35 Integrated Voltage Measurement... 00:57:55 Voltage Offset Correction: v_off_ini = 0.000002397 V, v_off_fin = 0.000007174 V 00:57:55 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175430361 Vs 00:57:55 Integrated Voltage Measurement... 00:58:14 Voltage Offset Correction: v_off_ini = 0.000006273 V, v_off_fin = -0.000000226 V 00:58:14 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175288707 Vs 00:58:17 Temperature Measurement, Probe Number = 0, T = 20.245000 C 00:58:18 Temperature Measurement, Probe Number = 1, T = 20.012000 C 00:58:18 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:58:19 Temperature Measurement, Probe Number = 3, T = 19.960000 C 00:58:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:58:19 Integrated Voltage Measurement... 00:58:39 Voltage Offset Correction: v_off_ini = 0.000003126 V, v_off_fin = 0.000007220 V 00:58:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175435443 Vs 00:58:39 Integrated Voltage Measurement... 00:58:58 Voltage Offset Correction: v_off_ini = 0.000006254 V, v_off_fin = -0.000000087 V 00:58:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289796 Vs 00:59:01 Temperature Measurement, Probe Number = 0, T = 20.224000 C 00:59:02 Temperature Measurement, Probe Number = 1, T = 20.014000 C 00:59:02 Temperature Measurement, Probe Number = 2, T = 19.982000 C 00:59:03 Temperature Measurement, Probe Number = 3, T = 19.963000 C 00:59:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 00:59:03 Integrated Voltage Measurement... 00:59:23 Voltage Offset Correction: v_off_ini = 0.000002316 V, v_off_fin = 0.000007202 V 00:59:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435019 Vs 00:59:23 Integrated Voltage Measurement... 00:59:42 Voltage Offset Correction: v_off_ini = 0.000005976 V, v_off_fin = -0.000000999 V 00:59:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294165 Vs 00:59:45 Temperature Measurement, Probe Number = 0, T = 20.258000 C 00:59:46 Temperature Measurement, Probe Number = 1, T = 20.015000 C 00:59:46 Temperature Measurement, Probe Number = 2, T = 19.982000 C 00:59:47 Temperature Measurement, Probe Number = 3, T = 19.966000 C 00:59:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:59:47 Integrated Voltage Measurement... 01:00:06 Voltage Offset Correction: v_off_ini = 0.000002110 V, v_off_fin = 0.000006634 V 01:00:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431900 Vs 01:00:06 Integrated Voltage Measurement... 01:00:26 Voltage Offset Correction: v_off_ini = 0.000005791 V, v_off_fin = -0.000000086 V 01:00:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175300062 Vs 01:00:29 Temperature Measurement, Probe Number = 0, T = 20.329000 C 01:00:30 Temperature Measurement, Probe Number = 1, T = 20.015000 C 01:00:30 Temperature Measurement, Probe Number = 2, T = 19.983000 C 01:00:31 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:00:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:00:31 Integrated Voltage Measurement... 01:00:50 Voltage Offset Correction: v_off_ini = 0.000002714 V, v_off_fin = 0.000007223 V 01:00:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175430928 Vs 01:00:51 Integrated Voltage Measurement... 01:01:10 Voltage Offset Correction: v_off_ini = 0.000006304 V, v_off_fin = -0.000000777 V 01:01:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301633 Vs 01:31:13 Temperature Measurement, Probe Number = 0, T = 20.262000 C 01:31:14 Temperature Measurement, Probe Number = 1, T = 20.014000 C 01:31:14 Temperature Measurement, Probe Number = 2, T = 19.983000 C 01:31:15 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:31:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:31:15 Integrated Voltage Measurement... 01:31:35 Voltage Offset Correction: v_off_ini = 0.000004551 V, v_off_fin = 0.000007013 V 01:31:35 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175531779 Vs 01:31:35 Integrated Voltage Measurement... 01:31:55 Voltage Offset Correction: v_off_ini = 0.000006053 V, v_off_fin = 0.000001259 V 01:31:56 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175284288 Vs 01:31:58 Temperature Measurement, Probe Number = 0, T = 20.260000 C 01:31:59 Temperature Measurement, Probe Number = 1, T = 20.015000 C 01:32:00 Temperature Measurement, Probe Number = 2, T = 19.987000 C 01:32:00 Temperature Measurement, Probe Number = 3, T = 19.964000 C 01:32:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 01:32:00 Integrated Voltage Measurement... 01:32:20 Voltage Offset Correction: v_off_ini = 0.000002553 V, v_off_fin = 0.000006832 V 01:32:20 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175406402 Vs 01:32:20 Integrated Voltage Measurement... 01:32:41 Voltage Offset Correction: v_off_ini = 0.000005921 V, v_off_fin = 0.000000691 V 01:32:41 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175289997 Vs 01:32:43 Temperature Measurement, Probe Number = 0, T = 20.247000 C 01:32:44 Temperature Measurement, Probe Number = 1, T = 20.013000 C 01:32:45 Temperature Measurement, Probe Number = 2, T = 19.983000 C 01:32:45 Temperature Measurement, Probe Number = 3, T = 19.964000 C 01:32:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:32:46 Integrated Voltage Measurement... 01:33:05 Voltage Offset Correction: v_off_ini = 0.000002662 V, v_off_fin = 0.000006392 V 01:33:05 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175405422 Vs 01:33:05 Integrated Voltage Measurement... 01:33:25 Voltage Offset Correction: v_off_ini = 0.000005492 V, v_off_fin = -0.000001050 V 01:33:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175306548 Vs 01:33:28 Temperature Measurement, Probe Number = 0, T = 20.211000 C 01:33:28 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:33:29 Temperature Measurement, Probe Number = 2, T = 19.980000 C 01:33:30 Temperature Measurement, Probe Number = 3, T = 19.961000 C 01:33:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:33:30 Integrated Voltage Measurement... 01:33:49 Voltage Offset Correction: v_off_ini = 0.000002301 V, v_off_fin = 0.000006955 V 01:33:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175419934 Vs 01:33:49 Integrated Voltage Measurement... 01:34:08 Voltage Offset Correction: v_off_ini = 0.000006357 V, v_off_fin = -0.000001244 V 01:34:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290176 Vs 01:34:11 Temperature Measurement, Probe Number = 0, T = 20.196000 C 01:34:12 Temperature Measurement, Probe Number = 1, T = 20.014000 C 01:34:12 Temperature Measurement, Probe Number = 2, T = 19.984000 C 01:34:13 Temperature Measurement, Probe Number = 3, T = 19.962000 C 01:34:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:34:13 Integrated Voltage Measurement... 01:34:32 Voltage Offset Correction: v_off_ini = 0.000002180 V, v_off_fin = 0.000006845 V 01:34:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428554 Vs 01:34:33 Integrated Voltage Measurement... 01:34:52 Voltage Offset Correction: v_off_ini = 0.000005864 V, v_off_fin = -0.000000513 V 01:34:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295467 Vs 01:34:55 Temperature Measurement, Probe Number = 0, T = 20.230000 C 01:34:55 Temperature Measurement, Probe Number = 1, T = 20.016000 C 01:34:56 Temperature Measurement, Probe Number = 2, T = 19.986000 C 01:34:57 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:34:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 01:34:57 Integrated Voltage Measurement... 01:35:16 Voltage Offset Correction: v_off_ini = 0.000002697 V, v_off_fin = 0.000007299 V 01:35:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428287 Vs 01:35:16 Integrated Voltage Measurement... 01:35:36 Voltage Offset Correction: v_off_ini = 0.000006070 V, v_off_fin = -0.000000451 V 01:35:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291009 Vs 01:35:38 Temperature Measurement, Probe Number = 0, T = 20.245000 C 01:35:39 Temperature Measurement, Probe Number = 1, T = 20.016000 C 01:35:40 Temperature Measurement, Probe Number = 2, T = 19.985000 C 01:35:40 Temperature Measurement, Probe Number = 3, T = 19.964000 C 01:35:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:35:41 Integrated Voltage Measurement... 01:36:00 Voltage Offset Correction: v_off_ini = 0.000001512 V, v_off_fin = 0.000006394 V 01:36:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417834 Vs 01:36:01 Integrated Voltage Measurement... 01:36:20 Voltage Offset Correction: v_off_ini = 0.000005215 V, v_off_fin = -0.000000794 V 01:36:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305636 Vs 01:36:23 Temperature Measurement, Probe Number = 0, T = 20.138000 C 01:36:24 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:36:24 Temperature Measurement, Probe Number = 2, T = 19.982000 C 01:36:25 Temperature Measurement, Probe Number = 3, T = 19.960000 C 01:36:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:36:25 Integrated Voltage Measurement... 01:36:44 Voltage Offset Correction: v_off_ini = 0.000002318 V, v_off_fin = 0.000006722 V 01:36:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422901 Vs 01:36:45 Integrated Voltage Measurement... 01:37:04 Voltage Offset Correction: v_off_ini = 0.000006306 V, v_off_fin = -0.000000661 V 01:37:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290945 Vs 01:37:06 Temperature Measurement, Probe Number = 0, T = 20.080000 C 01:37:07 Temperature Measurement, Probe Number = 1, T = 20.013000 C 01:37:08 Temperature Measurement, Probe Number = 2, T = 19.984000 C 01:37:08 Temperature Measurement, Probe Number = 3, T = 19.962000 C 01:37:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:37:09 Integrated Voltage Measurement... 01:37:28 Voltage Offset Correction: v_off_ini = 0.000002517 V, v_off_fin = 0.000006738 V 01:37:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428452 Vs 01:37:28 Integrated Voltage Measurement... 01:37:47 Voltage Offset Correction: v_off_ini = 0.000005868 V, v_off_fin = -0.000000389 V 01:37:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294078 Vs 01:37:50 Temperature Measurement, Probe Number = 0, T = 20.150000 C 01:37:51 Temperature Measurement, Probe Number = 1, T = 20.016000 C 01:37:51 Temperature Measurement, Probe Number = 2, T = 19.986000 C 01:37:52 Temperature Measurement, Probe Number = 3, T = 19.966000 C 01:37:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:37:52 Integrated Voltage Measurement... 01:38:12 Voltage Offset Correction: v_off_ini = 0.000002487 V, v_off_fin = 0.000007515 V 01:38:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175428746 Vs 01:38:12 Integrated Voltage Measurement... 01:38:31 Voltage Offset Correction: v_off_ini = 0.000005885 V, v_off_fin = -0.000000806 V 01:38:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299257 Vs 02:08:34 Temperature Measurement, Probe Number = 0, T = 20.344000 C 02:08:35 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:08:36 Temperature Measurement, Probe Number = 2, T = 19.991000 C 02:08:36 Temperature Measurement, Probe Number = 3, T = 19.969000 C 02:08:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:08:36 Integrated Voltage Measurement... 02:08:55 Voltage Offset Correction: v_off_ini = 0.000004713 V, v_off_fin = 0.000007139 V 02:08:56 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175529675 Vs 02:08:56 Integrated Voltage Measurement... 02:09:15 Voltage Offset Correction: v_off_ini = 0.000006616 V, v_off_fin = -0.000000945 V 02:09:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284756 Vs 02:09:18 Temperature Measurement, Probe Number = 0, T = 20.331000 C 02:09:19 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:09:19 Temperature Measurement, Probe Number = 2, T = 19.990000 C 02:09:20 Temperature Measurement, Probe Number = 3, T = 19.970000 C 02:09:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:09:20 Integrated Voltage Measurement... 02:09:39 Voltage Offset Correction: v_off_ini = 0.000001574 V, v_off_fin = 0.000006583 V 02:09:40 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175405194 Vs 02:09:40 Integrated Voltage Measurement... 02:09:59 Voltage Offset Correction: v_off_ini = 0.000006160 V, v_off_fin = 0.000000008 V 02:09:59 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175273427 Vs 02:10:02 Temperature Measurement, Probe Number = 0, T = 20.321000 C 02:10:03 Temperature Measurement, Probe Number = 1, T = 20.019000 C 02:10:03 Temperature Measurement, Probe Number = 2, T = 19.992000 C 02:10:04 Temperature Measurement, Probe Number = 3, T = 19.968000 C 02:10:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:10:04 Integrated Voltage Measurement... 02:10:23 Voltage Offset Correction: v_off_ini = 0.000002443 V, v_off_fin = 0.000007002 V 02:10:24 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175408042 Vs 02:10:24 Integrated Voltage Measurement... 02:10:43 Voltage Offset Correction: v_off_ini = 0.000005717 V, v_off_fin = -0.000000953 V 02:10:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283102 Vs 02:10:46 Temperature Measurement, Probe Number = 0, T = 20.290000 C 02:10:47 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:10:47 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:10:48 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:10:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:10:48 Integrated Voltage Measurement... 02:11:08 Voltage Offset Correction: v_off_ini = 0.000001658 V, v_off_fin = 0.000006910 V 02:11:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175418275 Vs 02:11:08 Integrated Voltage Measurement... 02:11:27 Voltage Offset Correction: v_off_ini = 0.000005969 V, v_off_fin = -0.000000442 V 02:11:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175288921 Vs 02:11:30 Temperature Measurement, Probe Number = 0, T = 20.201000 C 02:11:31 Temperature Measurement, Probe Number = 1, T = 20.019000 C 02:11:31 Temperature Measurement, Probe Number = 2, T = 19.990000 C 02:11:32 Temperature Measurement, Probe Number = 3, T = 19.968000 C 02:11:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:11:32 Integrated Voltage Measurement... 02:11:52 Voltage Offset Correction: v_off_ini = 0.000001837 V, v_off_fin = 0.000006389 V 02:11:52 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175407200 Vs 02:11:52 Integrated Voltage Measurement... 02:12:11 Voltage Offset Correction: v_off_ini = 0.000005888 V, v_off_fin = -0.000000432 V 02:12:11 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175287578 Vs 02:12:14 Temperature Measurement, Probe Number = 0, T = 20.085000 C 02:12:15 Temperature Measurement, Probe Number = 1, T = 20.020000 C 02:12:16 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:12:16 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:12:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:12:16 Integrated Voltage Measurement... 02:12:36 Voltage Offset Correction: v_off_ini = 0.000002326 V, v_off_fin = 0.000006883 V 02:12:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175412643 Vs 02:12:36 Integrated Voltage Measurement... 02:12:56 Voltage Offset Correction: v_off_ini = 0.000006196 V, v_off_fin = -0.000000315 V 02:12:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295441 Vs 02:12:59 Temperature Measurement, Probe Number = 0, T = 20.104000 C 02:12:59 Temperature Measurement, Probe Number = 1, T = 20.019000 C 02:13:00 Temperature Measurement, Probe Number = 2, T = 19.989000 C 02:13:01 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:13:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:13:01 Integrated Voltage Measurement... 02:13:20 Voltage Offset Correction: v_off_ini = 0.000001918 V, v_off_fin = 0.000006753 V 02:13:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417589 Vs 02:13:20 Integrated Voltage Measurement... 02:13:40 Voltage Offset Correction: v_off_ini = 0.000005566 V, v_off_fin = -0.000001181 V 02:13:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289733 Vs 02:13:42 Temperature Measurement, Probe Number = 0, T = 20.101000 C 02:13:43 Temperature Measurement, Probe Number = 1, T = 20.019000 C 02:13:44 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:13:44 Temperature Measurement, Probe Number = 3, T = 19.968000 C 02:13:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:13:45 Integrated Voltage Measurement... 02:14:04 Voltage Offset Correction: v_off_ini = 0.000001864 V, v_off_fin = 0.000006753 V 02:14:04 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175414315 Vs 02:14:04 Integrated Voltage Measurement... 02:14:24 Voltage Offset Correction: v_off_ini = 0.000006061 V, v_off_fin = -0.000000462 V 02:14:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175290377 Vs 02:14:26 Temperature Measurement, Probe Number = 0, T = 20.141000 C 02:14:27 Temperature Measurement, Probe Number = 1, T = 20.021000 C 02:14:28 Temperature Measurement, Probe Number = 2, T = 19.989000 C 02:14:28 Temperature Measurement, Probe Number = 3, T = 19.968000 C 02:14:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:14:29 Integrated Voltage Measurement... 02:14:48 Voltage Offset Correction: v_off_ini = 0.000002226 V, v_off_fin = 0.000006925 V 02:14:48 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175409768 Vs 02:14:48 Integrated Voltage Measurement... 02:15:08 Voltage Offset Correction: v_off_ini = 0.000005830 V, v_off_fin = -0.000000467 V 02:15:08 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296188 Vs 02:15:10 Temperature Measurement, Probe Number = 0, T = 20.217000 C 02:15:11 Temperature Measurement, Probe Number = 1, T = 20.021000 C 02:15:12 Temperature Measurement, Probe Number = 2, T = 19.990000 C 02:15:12 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:15:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:15:13 Integrated Voltage Measurement... 02:15:33 Voltage Offset Correction: v_off_ini = 0.000002359 V, v_off_fin = 0.000006884 V 02:15:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175419762 Vs 02:15:33 Integrated Voltage Measurement... 02:15:52 Voltage Offset Correction: v_off_ini = 0.000005850 V, v_off_fin = -0.000000924 V 02:15:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175280294 Vs 02:45:55 Temperature Measurement, Probe Number = 0, T = 20.157000 C 02:45:56 Temperature Measurement, Probe Number = 1, T = 20.016000 C 02:45:56 Temperature Measurement, Probe Number = 2, T = 19.983000 C 02:45:57 Temperature Measurement, Probe Number = 3, T = 19.963000 C 02:45:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:45:57 Integrated Voltage Measurement... 02:46:17 Voltage Offset Correction: v_off_ini = 0.000004820 V, v_off_fin = 0.000007061 V 02:46:17 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175518653 Vs 02:46:17 Integrated Voltage Measurement... 02:46:36 Voltage Offset Correction: v_off_ini = 0.000006609 V, v_off_fin = -0.000000159 V 02:46:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175277871 Vs 02:46:39 Temperature Measurement, Probe Number = 0, T = 20.147000 C 02:46:40 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:46:40 Temperature Measurement, Probe Number = 2, T = 19.985000 C 02:46:41 Temperature Measurement, Probe Number = 3, T = 19.965000 C 02:46:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:46:41 Integrated Voltage Measurement... 02:47:01 Voltage Offset Correction: v_off_ini = 0.000002847 V, v_off_fin = 0.000007361 V 02:47:01 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175427541 Vs 02:47:01 Integrated Voltage Measurement... 02:47:21 Voltage Offset Correction: v_off_ini = 0.000006469 V, v_off_fin = -0.000000467 V 02:47:21 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175288411 Vs 02:47:23 Temperature Measurement, Probe Number = 0, T = 20.172000 C 02:47:24 Temperature Measurement, Probe Number = 1, T = 20.021000 C 02:47:25 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:47:25 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:47:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:47:26 Integrated Voltage Measurement... 02:47:45 Voltage Offset Correction: v_off_ini = 0.000001833 V, v_off_fin = 0.000006739 V 02:47:45 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175420082 Vs 02:47:45 Integrated Voltage Measurement... 02:48:05 Voltage Offset Correction: v_off_ini = 0.000005932 V, v_off_fin = -0.000000472 V 02:48:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285031 Vs 02:48:07 Temperature Measurement, Probe Number = 0, T = 20.209000 C 02:48:08 Temperature Measurement, Probe Number = 1, T = 20.021000 C 02:48:09 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:48:09 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:48:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:48:10 Integrated Voltage Measurement... 02:48:31 Voltage Offset Correction: v_off_ini = 0.000001708 V, v_off_fin = 0.000005722 V 02:48:31 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175416445 Vs 02:48:31 Integrated Voltage Measurement... 02:48:50 Voltage Offset Correction: v_off_ini = 0.000005558 V, v_off_fin = -0.000000631 V 02:48:51 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175290445 Vs 02:48:53 Temperature Measurement, Probe Number = 0, T = 20.226000 C 02:48:54 Temperature Measurement, Probe Number = 1, T = 20.023000 C 02:48:55 Temperature Measurement, Probe Number = 2, T = 19.991000 C 02:48:55 Temperature Measurement, Probe Number = 3, T = 19.968000 C 02:48:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:48:56 Integrated Voltage Measurement... 02:49:15 Voltage Offset Correction: v_off_ini = 0.000001794 V, v_off_fin = 0.000006763 V 02:49:15 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175415381 Vs 02:49:15 Integrated Voltage Measurement... 02:49:34 Voltage Offset Correction: v_off_ini = 0.000005567 V, v_off_fin = -0.000001709 V 02:49:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175292480 Vs 02:49:37 Temperature Measurement, Probe Number = 0, T = 20.237000 C 02:49:38 Temperature Measurement, Probe Number = 1, T = 20.021000 C 02:49:38 Temperature Measurement, Probe Number = 2, T = 19.991000 C 02:49:39 Temperature Measurement, Probe Number = 3, T = 19.969000 C 02:49:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:49:39 Integrated Voltage Measurement... 02:49:58 Voltage Offset Correction: v_off_ini = 0.000001870 V, v_off_fin = 0.000006534 V 02:49:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417138 Vs 02:49:59 Integrated Voltage Measurement... 02:50:18 Voltage Offset Correction: v_off_ini = 0.000005721 V, v_off_fin = -0.000000656 V 02:50:18 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175290711 Vs 02:50:21 Temperature Measurement, Probe Number = 0, T = 20.229000 C 02:50:21 Temperature Measurement, Probe Number = 1, T = 20.017000 C 02:50:22 Temperature Measurement, Probe Number = 2, T = 19.986000 C 02:50:23 Temperature Measurement, Probe Number = 3, T = 19.965000 C 02:50:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 02:50:23 Integrated Voltage Measurement... 02:50:42 Voltage Offset Correction: v_off_ini = 0.000002235 V, v_off_fin = 0.000006850 V 02:50:42 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175416148 Vs 02:50:42 Integrated Voltage Measurement... 02:51:02 Voltage Offset Correction: v_off_ini = 0.000005682 V, v_off_fin = 0.000000009 V 02:51:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175315998 Vs 02:51:05 Temperature Measurement, Probe Number = 0, T = 20.163000 C 02:51:06 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:51:06 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:51:07 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:51:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:51:07 Integrated Voltage Measurement... 02:51:26 Voltage Offset Correction: v_off_ini = 0.000002890 V, v_off_fin = 0.000007136 V 02:51:26 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175414560 Vs 02:51:27 Integrated Voltage Measurement... 02:51:46 Voltage Offset Correction: v_off_ini = 0.000006322 V, v_off_fin = 0.000000032 V 02:51:46 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175297639 Vs 02:51:49 Temperature Measurement, Probe Number = 0, T = 20.126000 C 02:51:50 Temperature Measurement, Probe Number = 1, T = 20.020000 C 02:51:50 Temperature Measurement, Probe Number = 2, T = 19.989000 C 02:51:51 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:51:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:51:51 Integrated Voltage Measurement... 02:52:11 Voltage Offset Correction: v_off_ini = 0.000002656 V, v_off_fin = 0.000006471 V 02:52:11 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175417214 Vs 02:52:11 Integrated Voltage Measurement... 02:52:32 Voltage Offset Correction: v_off_ini = 0.000005777 V, v_off_fin = 0.000000574 V 02:52:32 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.175288037 Vs 02:52:35 Temperature Measurement, Probe Number = 0, T = 20.098000 C 02:52:35 Temperature Measurement, Probe Number = 1, T = 20.020000 C 02:52:36 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:52:37 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:52:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:52:37 Integrated Voltage Measurement... 02:52:56 Voltage Offset Correction: v_off_ini = 0.000002546 V, v_off_fin = 0.000006802 V 02:52:56 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175404769 Vs 02:52:56 Integrated Voltage Measurement... 02:53:17 Voltage Offset Correction: v_off_ini = 0.000006297 V, v_off_fin = -0.000000162 V 02:53:17 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175290884 Vs 03:23:20 Temperature Measurement, Probe Number = 0, T = 20.282000 C 03:23:20 Temperature Measurement, Probe Number = 1, T = 20.021000 C 03:23:21 Temperature Measurement, Probe Number = 2, T = 19.993000 C 03:23:22 Temperature Measurement, Probe Number = 3, T = 19.972000 C 03:23:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:23:22 Integrated Voltage Measurement... 03:23:41 Voltage Offset Correction: v_off_ini = 0.000004996 V, v_off_fin = 0.000007372 V 03:23:41 Integrated Voltage Measurement Delta Gap = 0.0040024 m VT = 0.175499789 Vs 03:23:41 Integrated Voltage Measurement... 03:24:02 Voltage Offset Correction: v_off_ini = 0.000006577 V, v_off_fin = 0.000000821 V 03:24:02 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175279127 Vs 03:24:05 Temperature Measurement, Probe Number = 0, T = 20.308000 C 03:24:06 Temperature Measurement, Probe Number = 1, T = 20.023000 C 03:24:06 Temperature Measurement, Probe Number = 2, T = 19.997000 C 03:24:07 Temperature Measurement, Probe Number = 3, T = 19.973000 C 03:24:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 03:24:07 Integrated Voltage Measurement... 03:24:26 Voltage Offset Correction: v_off_ini = 0.000002375 V, v_off_fin = 0.000006848 V 03:24:27 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175406044 Vs 03:24:27 Integrated Voltage Measurement... 03:24:46 Voltage Offset Correction: v_off_ini = 0.000006166 V, v_off_fin = -0.000000136 V 03:24:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175290364 Vs 03:24:49 Temperature Measurement, Probe Number = 0, T = 20.324000 C 03:24:50 Temperature Measurement, Probe Number = 1, T = 20.022000 C 03:24:50 Temperature Measurement, Probe Number = 2, T = 19.995000 C 03:24:51 Temperature Measurement, Probe Number = 3, T = 19.973000 C 03:24:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 03:24:51 Integrated Voltage Measurement... 03:25:10 Voltage Offset Correction: v_off_ini = 0.000002012 V, v_off_fin = 0.000006552 V 03:25:10 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175412025 Vs 03:25:10 Integrated Voltage Measurement... 03:25:29 Voltage Offset Correction: v_off_ini = 0.000005150 V, v_off_fin = -0.000001481 V 03:25:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294000 Vs 03:25:32 Temperature Measurement, Probe Number = 0, T = 20.348000 C 03:25:33 Temperature Measurement, Probe Number = 1, T = 20.022000 C 03:25:34 Temperature Measurement, Probe Number = 2, T = 19.992000 C 03:25:34 Temperature Measurement, Probe Number = 3, T = 19.969000 C 03:25:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:25:35 Integrated Voltage Measurement... 03:25:54 Voltage Offset Correction: v_off_ini = 0.000001177 V, v_off_fin = 0.000007196 V 03:25:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421375 Vs 03:25:54 Integrated Voltage Measurement... 03:26:13 Voltage Offset Correction: v_off_ini = 0.000005503 V, v_off_fin = -0.000000374 V 03:26:13 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175286856 Vs 03:26:16 Temperature Measurement, Probe Number = 0, T = 20.295000 C 03:26:17 Temperature Measurement, Probe Number = 1, T = 20.023000 C 03:26:17 Temperature Measurement, Probe Number = 2, T = 19.993000 C 03:26:18 Temperature Measurement, Probe Number = 3, T = 19.972000 C 03:26:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:26:18 Integrated Voltage Measurement... 03:26:37 Voltage Offset Correction: v_off_ini = 0.000002740 V, v_off_fin = 0.000006833 V 03:26:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175423912 Vs 03:26:38 Integrated Voltage Measurement... 03:26:57 Voltage Offset Correction: v_off_ini = 0.000005817 V, v_off_fin = -0.000000142 V 03:26:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175287799 Vs 03:27:00 Temperature Measurement, Probe Number = 0, T = 20.315000 C 03:27:00 Temperature Measurement, Probe Number = 1, T = 20.023000 C 03:27:01 Temperature Measurement, Probe Number = 2, T = 19.995000 C 03:27:02 Temperature Measurement, Probe Number = 3, T = 19.974000 C 03:27:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 03:27:02 Integrated Voltage Measurement... 03:27:21 Voltage Offset Correction: v_off_ini = 0.000001871 V, v_off_fin = 0.000007041 V 03:27:21 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175427458 Vs 03:27:22 Integrated Voltage Measurement... 03:27:41 Voltage Offset Correction: v_off_ini = 0.000006121 V, v_off_fin = 0.000000072 V 03:27:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175288412 Vs 03:27:44 Temperature Measurement, Probe Number = 0, T = 20.299000 C 03:27:44 Temperature Measurement, Probe Number = 1, T = 20.019000 C 03:27:45 Temperature Measurement, Probe Number = 2, T = 19.988000 C 03:27:46 Temperature Measurement, Probe Number = 3, T = 19.967000 C 03:27:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:27:46 Integrated Voltage Measurement... 03:28:05 Voltage Offset Correction: v_off_ini = 0.000002933 V, v_off_fin = 0.000006996 V 03:28:05 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175425775 Vs 03:28:05 Integrated Voltage Measurement... 03:28:25 Voltage Offset Correction: v_off_ini = 0.000006309 V, v_off_fin = -0.000001106 V 03:28:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175292878 Vs 03:28:27 Temperature Measurement, Probe Number = 0, T = 20.224000 C 03:28:28 Temperature Measurement, Probe Number = 1, T = 20.017000 C 03:28:29 Temperature Measurement, Probe Number = 2, T = 19.988000 C 03:28:29 Temperature Measurement, Probe Number = 3, T = 19.965000 C 03:28:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 03:28:30 Integrated Voltage Measurement... 03:28:49 Voltage Offset Correction: v_off_ini = 0.000001500 V, v_off_fin = 0.000006661 V 03:28:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421222 Vs 03:28:49 Integrated Voltage Measurement... 03:29:08 Voltage Offset Correction: v_off_ini = 0.000005606 V, v_off_fin = -0.000001111 V 03:29:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304329 Vs 03:29:11 Temperature Measurement, Probe Number = 0, T = 20.146000 C 03:29:12 Temperature Measurement, Probe Number = 1, T = 20.020000 C 03:29:13 Temperature Measurement, Probe Number = 2, T = 19.990000 C 03:29:13 Temperature Measurement, Probe Number = 3, T = 19.970000 C 03:29:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:29:14 Integrated Voltage Measurement... 03:29:33 Voltage Offset Correction: v_off_ini = 0.000001579 V, v_off_fin = 0.000006238 V 03:29:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417966 Vs 03:29:33 Integrated Voltage Measurement... 03:29:52 Voltage Offset Correction: v_off_ini = 0.000005494 V, v_off_fin = -0.000000604 V 03:29:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297265 Vs 03:29:55 Temperature Measurement, Probe Number = 0, T = 20.228000 C 03:29:56 Temperature Measurement, Probe Number = 1, T = 20.020000 C 03:29:56 Temperature Measurement, Probe Number = 2, T = 19.991000 C 03:29:57 Temperature Measurement, Probe Number = 3, T = 19.970000 C 03:29:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:29:57 Integrated Voltage Measurement... 03:30:16 Voltage Offset Correction: v_off_ini = 0.000002080 V, v_off_fin = 0.000006984 V 03:30:17 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175426436 Vs 03:30:17 Integrated Voltage Measurement... 03:30:36 Voltage Offset Correction: v_off_ini = 0.000005836 V, v_off_fin = 0.000000375 V 03:30:36 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175292950 Vs 04:00:39 Temperature Measurement, Probe Number = 0, T = 20.049000 C 04:00:40 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:00:40 Temperature Measurement, Probe Number = 2, T = 19.992000 C 04:00:41 Temperature Measurement, Probe Number = 3, T = 19.968000 C 04:00:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:00:41 Integrated Voltage Measurement... 04:01:00 Voltage Offset Correction: v_off_ini = 0.000004181 V, v_off_fin = 0.000006389 V 04:01:01 Integrated Voltage Measurement Delta Gap = 0.0040027 m VT = 0.175512712 Vs 04:01:01 Integrated Voltage Measurement... 04:01:20 Voltage Offset Correction: v_off_ini = 0.000005845 V, v_off_fin = 0.000000463 V 04:01:20 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293032 Vs 04:01:23 Temperature Measurement, Probe Number = 0, T = 20.071000 C 04:01:23 Temperature Measurement, Probe Number = 1, T = 20.021000 C 04:01:24 Temperature Measurement, Probe Number = 2, T = 19.992000 C 04:01:25 Temperature Measurement, Probe Number = 3, T = 19.969000 C 04:01:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:01:25 Integrated Voltage Measurement... 04:01:44 Voltage Offset Correction: v_off_ini = 0.000002228 V, v_off_fin = 0.000006651 V 04:01:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175418645 Vs 04:01:44 Integrated Voltage Measurement... 04:02:04 Voltage Offset Correction: v_off_ini = 0.000005652 V, v_off_fin = -0.000000178 V 04:02:04 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175287314 Vs 04:02:07 Temperature Measurement, Probe Number = 0, T = 20.096000 C 04:02:08 Temperature Measurement, Probe Number = 1, T = 20.021000 C 04:02:08 Temperature Measurement, Probe Number = 2, T = 19.994000 C 04:02:09 Temperature Measurement, Probe Number = 3, T = 19.969000 C 04:02:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:02:09 Integrated Voltage Measurement... 04:02:29 Voltage Offset Correction: v_off_ini = 0.000002740 V, v_off_fin = 0.000006437 V 04:02:29 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175412569 Vs 04:02:29 Integrated Voltage Measurement... 04:02:48 Voltage Offset Correction: v_off_ini = 0.000005596 V, v_off_fin = -0.000000657 V 04:02:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294482 Vs 04:02:51 Temperature Measurement, Probe Number = 0, T = 20.055000 C 04:02:52 Temperature Measurement, Probe Number = 1, T = 20.020000 C 04:02:53 Temperature Measurement, Probe Number = 2, T = 19.991000 C 04:02:53 Temperature Measurement, Probe Number = 3, T = 19.970000 C 04:02:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:02:54 Integrated Voltage Measurement... 04:03:13 Voltage Offset Correction: v_off_ini = 0.000001828 V, v_off_fin = 0.000006164 V 04:03:14 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175421739 Vs 04:03:14 Integrated Voltage Measurement... 04:03:33 Voltage Offset Correction: v_off_ini = 0.000005195 V, v_off_fin = -0.000001268 V 04:03:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297051 Vs 04:03:36 Temperature Measurement, Probe Number = 0, T = 20.119000 C 04:03:37 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:03:37 Temperature Measurement, Probe Number = 2, T = 19.992000 C 04:03:38 Temperature Measurement, Probe Number = 3, T = 19.969000 C 04:03:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:03:38 Integrated Voltage Measurement... 04:03:57 Voltage Offset Correction: v_off_ini = 0.000001999 V, v_off_fin = 0.000007007 V 04:03:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427779 Vs 04:03:58 Integrated Voltage Measurement... 04:04:17 Voltage Offset Correction: v_off_ini = 0.000005979 V, v_off_fin = -0.000000388 V 04:04:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293374 Vs 04:04:20 Temperature Measurement, Probe Number = 0, T = 20.163000 C 04:04:20 Temperature Measurement, Probe Number = 1, T = 20.020000 C 04:04:21 Temperature Measurement, Probe Number = 2, T = 19.992000 C 04:04:22 Temperature Measurement, Probe Number = 3, T = 19.969000 C 04:04:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:04:22 Integrated Voltage Measurement... 04:04:41 Voltage Offset Correction: v_off_ini = 0.000001739 V, v_off_fin = 0.000007056 V 04:04:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427772 Vs 04:04:41 Integrated Voltage Measurement... 04:05:01 Voltage Offset Correction: v_off_ini = 0.000005904 V, v_off_fin = -0.000000590 V 04:05:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294346 Vs 04:05:04 Temperature Measurement, Probe Number = 0, T = 20.222000 C 04:05:04 Temperature Measurement, Probe Number = 1, T = 20.021000 C 04:05:05 Temperature Measurement, Probe Number = 2, T = 19.993000 C 04:05:06 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:05:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:05:06 Integrated Voltage Measurement... 04:05:26 Voltage Offset Correction: v_off_ini = 0.000002528 V, v_off_fin = 0.000006938 V 04:05:26 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175429048 Vs 04:05:26 Integrated Voltage Measurement... 04:05:45 Voltage Offset Correction: v_off_ini = 0.000005523 V, v_off_fin = -0.000000737 V 04:05:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296928 Vs 04:05:48 Temperature Measurement, Probe Number = 0, T = 20.262000 C 04:05:49 Temperature Measurement, Probe Number = 1, T = 20.024000 C 04:05:49 Temperature Measurement, Probe Number = 2, T = 19.994000 C 04:05:50 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:05:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:05:50 Integrated Voltage Measurement... 04:06:09 Voltage Offset Correction: v_off_ini = 0.000001975 V, v_off_fin = 0.000007044 V 04:06:09 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432623 Vs 04:06:09 Integrated Voltage Measurement... 04:06:29 Voltage Offset Correction: v_off_ini = 0.000006030 V, v_off_fin = -0.000000139 V 04:06:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296629 Vs 04:06:31 Temperature Measurement, Probe Number = 0, T = 20.245000 C 04:06:32 Temperature Measurement, Probe Number = 1, T = 20.023000 C 04:06:33 Temperature Measurement, Probe Number = 2, T = 19.994000 C 04:06:33 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:06:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:06:34 Integrated Voltage Measurement... 04:06:53 Voltage Offset Correction: v_off_ini = 0.000002663 V, v_off_fin = 0.000007284 V 04:06:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175431591 Vs 04:06:53 Integrated Voltage Measurement... 04:07:12 Voltage Offset Correction: v_off_ini = 0.000006302 V, v_off_fin = 0.000000144 V 04:07:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293144 Vs 04:07:15 Temperature Measurement, Probe Number = 0, T = 20.185000 C 04:07:16 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:07:17 Temperature Measurement, Probe Number = 2, T = 19.994000 C 04:07:17 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:07:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:07:18 Integrated Voltage Measurement... 04:07:37 Voltage Offset Correction: v_off_ini = 0.000003106 V, v_off_fin = 0.000007501 V 04:07:37 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175431013 Vs 04:07:38 Integrated Voltage Measurement... 04:07:57 Voltage Offset Correction: v_off_ini = 0.000006618 V, v_off_fin = 0.000000952 V 04:07:58 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175287936 Vs 04:38:00 Temperature Measurement, Probe Number = 0, T = 20.295000 C 04:38:01 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:38:02 Temperature Measurement, Probe Number = 2, T = 19.997000 C 04:38:02 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:38:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:38:03 Integrated Voltage Measurement... 04:38:22 Voltage Offset Correction: v_off_ini = 0.000004264 V, v_off_fin = 0.000006748 V 04:38:22 Integrated Voltage Measurement Delta Gap = 0.0040027 m VT = 0.175514663 Vs 04:38:22 Integrated Voltage Measurement... 04:38:43 Voltage Offset Correction: v_off_ini = 0.000005941 V, v_off_fin = 0.000000639 V 04:38:43 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175302223 Vs 04:38:46 Temperature Measurement, Probe Number = 0, T = 20.280000 C 04:38:47 Temperature Measurement, Probe Number = 1, T = 20.023000 C 04:38:47 Temperature Measurement, Probe Number = 2, T = 19.999000 C 04:38:48 Temperature Measurement, Probe Number = 3, T = 19.975000 C 04:38:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 04:38:48 Integrated Voltage Measurement... 04:39:08 Voltage Offset Correction: v_off_ini = 0.000002280 V, v_off_fin = 0.000005784 V 04:39:08 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175417181 Vs 04:39:08 Integrated Voltage Measurement... 04:39:27 Voltage Offset Correction: v_off_ini = 0.000005855 V, v_off_fin = -0.000001656 V 04:39:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306148 Vs 04:39:30 Temperature Measurement, Probe Number = 0, T = 20.261000 C 04:39:31 Temperature Measurement, Probe Number = 1, T = 20.023000 C 04:39:31 Temperature Measurement, Probe Number = 2, T = 19.999000 C 04:39:32 Temperature Measurement, Probe Number = 3, T = 19.974000 C 04:39:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:39:32 Integrated Voltage Measurement... 04:39:51 Voltage Offset Correction: v_off_ini = 0.000002227 V, v_off_fin = 0.000007189 V 04:39:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436537 Vs 04:39:52 Integrated Voltage Measurement... 04:40:11 Voltage Offset Correction: v_off_ini = 0.000006461 V, v_off_fin = -0.000000961 V 04:40:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301144 Vs 04:40:14 Temperature Measurement, Probe Number = 0, T = 20.220000 C 04:40:15 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:40:15 Temperature Measurement, Probe Number = 2, T = 19.997000 C 04:40:16 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:40:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:40:16 Integrated Voltage Measurement... 04:40:35 Voltage Offset Correction: v_off_ini = 0.000002202 V, v_off_fin = 0.000007379 V 04:40:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175442029 Vs 04:40:36 Integrated Voltage Measurement... 04:40:55 Voltage Offset Correction: v_off_ini = 0.000005472 V, v_off_fin = -0.000000516 V 04:40:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300927 Vs 04:40:58 Temperature Measurement, Probe Number = 0, T = 20.260000 C 04:40:59 Temperature Measurement, Probe Number = 1, T = 20.024000 C 04:40:59 Temperature Measurement, Probe Number = 2, T = 19.997000 C 04:41:00 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:41:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:41:00 Integrated Voltage Measurement... 04:41:19 Voltage Offset Correction: v_off_ini = 0.000002618 V, v_off_fin = 0.000007139 V 04:41:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175443743 Vs 04:41:20 Integrated Voltage Measurement... 04:41:39 Voltage Offset Correction: v_off_ini = 0.000006151 V, v_off_fin = -0.000001160 V 04:41:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305063 Vs 04:41:42 Temperature Measurement, Probe Number = 0, T = 20.279000 C 04:41:42 Temperature Measurement, Probe Number = 1, T = 20.025000 C 04:41:43 Temperature Measurement, Probe Number = 2, T = 20.000000 C 04:41:44 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:41:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:41:44 Integrated Voltage Measurement... 04:42:03 Voltage Offset Correction: v_off_ini = 0.000002386 V, v_off_fin = 0.000006890 V 04:42:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443164 Vs 04:42:03 Integrated Voltage Measurement... 04:42:23 Voltage Offset Correction: v_off_ini = 0.000005874 V, v_off_fin = -0.000001360 V 04:42:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303974 Vs 04:42:26 Temperature Measurement, Probe Number = 0, T = 20.332000 C 04:42:26 Temperature Measurement, Probe Number = 1, T = 20.028000 C 04:42:27 Temperature Measurement, Probe Number = 2, T = 20.000000 C 04:42:28 Temperature Measurement, Probe Number = 3, T = 19.975000 C 04:42:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 04:42:28 Integrated Voltage Measurement... 04:42:48 Voltage Offset Correction: v_off_ini = 0.000002411 V, v_off_fin = 0.000006720 V 04:42:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175449234 Vs 04:42:48 Integrated Voltage Measurement... 04:43:07 Voltage Offset Correction: v_off_ini = 0.000005984 V, v_off_fin = -0.000001271 V 04:43:07 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304686 Vs 04:43:10 Temperature Measurement, Probe Number = 0, T = 20.344000 C 04:43:11 Temperature Measurement, Probe Number = 1, T = 20.025000 C 04:43:12 Temperature Measurement, Probe Number = 2, T = 19.998000 C 04:43:12 Temperature Measurement, Probe Number = 3, T = 19.970000 C 04:43:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:43:12 Integrated Voltage Measurement... 04:43:31 Voltage Offset Correction: v_off_ini = 0.000003034 V, v_off_fin = 0.000007160 V 04:43:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442621 Vs 04:43:32 Integrated Voltage Measurement... 04:43:51 Voltage Offset Correction: v_off_ini = 0.000006264 V, v_off_fin = -0.000001167 V 04:43:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303203 Vs 04:43:54 Temperature Measurement, Probe Number = 0, T = 20.343000 C 04:43:55 Temperature Measurement, Probe Number = 1, T = 20.024000 C 04:43:55 Temperature Measurement, Probe Number = 2, T = 19.998000 C 04:43:56 Temperature Measurement, Probe Number = 3, T = 19.971000 C 04:43:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:43:56 Integrated Voltage Measurement... 04:44:16 Voltage Offset Correction: v_off_ini = 0.000002475 V, v_off_fin = 0.000006853 V 04:44:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439916 Vs 04:44:16 Integrated Voltage Measurement... 04:44:36 Voltage Offset Correction: v_off_ini = 0.000005954 V, v_off_fin = -0.000000992 V 04:44:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323104 Vs 04:44:39 Temperature Measurement, Probe Number = 0, T = 20.271000 C 04:44:39 Temperature Measurement, Probe Number = 1, T = 20.025000 C 04:44:40 Temperature Measurement, Probe Number = 2, T = 19.996000 C 04:44:40 Temperature Measurement, Probe Number = 3, T = 19.971000 C 04:44:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 04:44:41 Integrated Voltage Measurement... 04:45:00 Voltage Offset Correction: v_off_ini = 0.000002197 V, v_off_fin = 0.000006647 V 04:45:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442547 Vs 04:45:00 Integrated Voltage Measurement... 04:45:19 Voltage Offset Correction: v_off_ini = 0.000005797 V, v_off_fin = -0.000001090 V 04:45:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309708 Vs 05:15:22 Temperature Measurement, Probe Number = 0, T = 20.002000 C 05:15:23 Temperature Measurement, Probe Number = 1, T = 20.021000 C 05:15:24 Temperature Measurement, Probe Number = 2, T = 19.991000 C 05:15:25 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:15:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:15:25 Integrated Voltage Measurement... 05:15:45 Voltage Offset Correction: v_off_ini = 0.000004746 V, v_off_fin = 0.000006849 V 05:15:45 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175539100 Vs 05:15:45 Integrated Voltage Measurement... 05:16:04 Voltage Offset Correction: v_off_ini = 0.000006215 V, v_off_fin = -0.000001854 V 05:16:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315250 Vs 05:16:07 Temperature Measurement, Probe Number = 0, T = 20.064000 C 05:16:08 Temperature Measurement, Probe Number = 1, T = 20.023000 C 05:16:09 Temperature Measurement, Probe Number = 2, T = 19.995000 C 05:16:09 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:16:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:16:10 Integrated Voltage Measurement... 05:16:29 Voltage Offset Correction: v_off_ini = 0.000001915 V, v_off_fin = 0.000006582 V 05:16:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440318 Vs 05:16:29 Integrated Voltage Measurement... 05:16:49 Voltage Offset Correction: v_off_ini = 0.000005885 V, v_off_fin = -0.000000892 V 05:16:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308840 Vs 05:16:51 Temperature Measurement, Probe Number = 0, T = 20.122000 C 05:16:52 Temperature Measurement, Probe Number = 1, T = 20.024000 C 05:16:53 Temperature Measurement, Probe Number = 2, T = 19.996000 C 05:16:53 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:16:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:16:54 Integrated Voltage Measurement... 05:17:13 Voltage Offset Correction: v_off_ini = 0.000002158 V, v_off_fin = 0.000007007 V 05:17:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440939 Vs 05:17:13 Integrated Voltage Measurement... 05:17:33 Voltage Offset Correction: v_off_ini = 0.000005898 V, v_off_fin = -0.000001793 V 05:17:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304763 Vs 05:17:36 Temperature Measurement, Probe Number = 0, T = 20.133000 C 05:17:36 Temperature Measurement, Probe Number = 1, T = 20.023000 C 05:17:37 Temperature Measurement, Probe Number = 2, T = 19.993000 C 05:17:37 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:17:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:17:38 Integrated Voltage Measurement... 05:17:57 Voltage Offset Correction: v_off_ini = 0.000001952 V, v_off_fin = 0.000006858 V 05:17:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440541 Vs 05:17:57 Integrated Voltage Measurement... 05:18:17 Voltage Offset Correction: v_off_ini = 0.000006293 V, v_off_fin = -0.000000639 V 05:18:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301509 Vs 05:18:20 Temperature Measurement, Probe Number = 0, T = 20.059000 C 05:18:21 Temperature Measurement, Probe Number = 1, T = 20.021000 C 05:18:21 Temperature Measurement, Probe Number = 2, T = 19.993000 C 05:18:22 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:18:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:18:22 Integrated Voltage Measurement... 05:18:42 Voltage Offset Correction: v_off_ini = 0.000002876 V, v_off_fin = 0.000007055 V 05:18:42 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175437728 Vs 05:18:42 Integrated Voltage Measurement... 05:19:02 Voltage Offset Correction: v_off_ini = 0.000005802 V, v_off_fin = -0.000001855 V 05:19:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301603 Vs 05:19:04 Temperature Measurement, Probe Number = 0, T = 20.089000 C 05:19:05 Temperature Measurement, Probe Number = 1, T = 20.024000 C 05:19:06 Temperature Measurement, Probe Number = 2, T = 19.994000 C 05:19:06 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:19:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:19:07 Integrated Voltage Measurement... 05:19:26 Voltage Offset Correction: v_off_ini = 0.000002330 V, v_off_fin = 0.000006308 V 05:19:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434204 Vs 05:19:26 Integrated Voltage Measurement... 05:19:46 Voltage Offset Correction: v_off_ini = 0.000005542 V, v_off_fin = -0.000000934 V 05:19:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313386 Vs 05:19:49 Temperature Measurement, Probe Number = 0, T = 20.138000 C 05:19:49 Temperature Measurement, Probe Number = 1, T = 20.025000 C 05:19:50 Temperature Measurement, Probe Number = 2, T = 19.995000 C 05:19:51 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:19:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:19:51 Integrated Voltage Measurement... 05:20:10 Voltage Offset Correction: v_off_ini = 0.000001789 V, v_off_fin = 0.000006963 V 05:20:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435094 Vs 05:20:10 Integrated Voltage Measurement... 05:20:30 Voltage Offset Correction: v_off_ini = 0.000006185 V, v_off_fin = -0.000001858 V 05:20:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307294 Vs 05:20:33 Temperature Measurement, Probe Number = 0, T = 20.187000 C 05:20:33 Temperature Measurement, Probe Number = 1, T = 20.021000 C 05:20:34 Temperature Measurement, Probe Number = 2, T = 19.995000 C 05:20:35 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:20:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:20:35 Integrated Voltage Measurement... 05:20:54 Voltage Offset Correction: v_off_ini = 0.000001679 V, v_off_fin = 0.000006765 V 05:20:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437176 Vs 05:20:54 Integrated Voltage Measurement... 05:21:14 Voltage Offset Correction: v_off_ini = 0.000005831 V, v_off_fin = -0.000000980 V 05:21:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304389 Vs 05:21:17 Temperature Measurement, Probe Number = 0, T = 20.239000 C 05:21:17 Temperature Measurement, Probe Number = 1, T = 20.024000 C 05:21:18 Temperature Measurement, Probe Number = 2, T = 19.996000 C 05:21:19 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:21:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:21:19 Integrated Voltage Measurement... 05:21:38 Voltage Offset Correction: v_off_ini = 0.000001709 V, v_off_fin = 0.000006906 V 05:21:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438576 Vs 05:21:38 Integrated Voltage Measurement... 05:21:58 Voltage Offset Correction: v_off_ini = 0.000006361 V, v_off_fin = -0.000001966 V 05:21:58 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175310626 Vs 05:22:01 Temperature Measurement, Probe Number = 0, T = 20.277000 C 05:22:01 Temperature Measurement, Probe Number = 1, T = 20.025000 C 05:22:02 Temperature Measurement, Probe Number = 2, T = 19.997000 C 05:22:03 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:22:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:22:03 Integrated Voltage Measurement... 05:22:22 Voltage Offset Correction: v_off_ini = 0.000001936 V, v_off_fin = 0.000007166 V 05:22:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438194 Vs 05:22:23 Integrated Voltage Measurement... 05:22:42 Voltage Offset Correction: v_off_ini = 0.000006176 V, v_off_fin = -0.000001217 V 05:22:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299472 Vs 05:52:45 Temperature Measurement, Probe Number = 0, T = 20.157000 C 05:52:46 Temperature Measurement, Probe Number = 1, T = 20.021000 C 05:52:46 Temperature Measurement, Probe Number = 2, T = 19.991000 C 05:52:47 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:52:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:52:47 Integrated Voltage Measurement... 05:53:07 Voltage Offset Correction: v_off_ini = 0.000004683 V, v_off_fin = 0.000007028 V 05:53:07 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175531315 Vs 05:53:07 Integrated Voltage Measurement... 05:53:27 Voltage Offset Correction: v_off_ini = 0.000005903 V, v_off_fin = -0.000001719 V 05:53:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304696 Vs 05:53:30 Temperature Measurement, Probe Number = 0, T = 20.130000 C 05:53:30 Temperature Measurement, Probe Number = 1, T = 20.022000 C 05:53:31 Temperature Measurement, Probe Number = 2, T = 19.996000 C 05:53:31 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:53:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:53:32 Integrated Voltage Measurement... 05:53:51 Voltage Offset Correction: v_off_ini = 0.000002160 V, v_off_fin = 0.000007097 V 05:53:51 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442323 Vs 05:53:51 Integrated Voltage Measurement... 05:54:11 Voltage Offset Correction: v_off_ini = 0.000006649 V, v_off_fin = -0.000001459 V 05:54:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304846 Vs 05:54:14 Temperature Measurement, Probe Number = 0, T = 20.189000 C 05:54:14 Temperature Measurement, Probe Number = 1, T = 20.022000 C 05:54:15 Temperature Measurement, Probe Number = 2, T = 19.998000 C 05:54:16 Temperature Measurement, Probe Number = 3, T = 19.973000 C 05:54:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:54:16 Integrated Voltage Measurement... 05:54:35 Voltage Offset Correction: v_off_ini = 0.000001998 V, v_off_fin = 0.000007236 V 05:54:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175448287 Vs 05:54:36 Integrated Voltage Measurement... 05:54:56 Voltage Offset Correction: v_off_ini = 0.000006326 V, v_off_fin = -0.000000341 V 05:54:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302295 Vs 05:54:59 Temperature Measurement, Probe Number = 0, T = 20.217000 C 05:54:59 Temperature Measurement, Probe Number = 1, T = 20.024000 C 05:55:00 Temperature Measurement, Probe Number = 2, T = 19.997000 C 05:55:01 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:55:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:55:01 Integrated Voltage Measurement... 05:55:20 Voltage Offset Correction: v_off_ini = 0.000002315 V, v_off_fin = 0.000006881 V 05:55:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437494 Vs 05:55:20 Integrated Voltage Measurement... 05:55:39 Voltage Offset Correction: v_off_ini = 0.000006160 V, v_off_fin = -0.000001640 V 05:55:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175301646 Vs 05:55:42 Temperature Measurement, Probe Number = 0, T = 20.209000 C 05:55:43 Temperature Measurement, Probe Number = 1, T = 20.023000 C 05:55:44 Temperature Measurement, Probe Number = 2, T = 19.996000 C 05:55:44 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:55:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:55:45 Integrated Voltage Measurement... 05:56:04 Voltage Offset Correction: v_off_ini = 0.000001505 V, v_off_fin = 0.000006258 V 05:56:04 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175441609 Vs 05:56:04 Integrated Voltage Measurement... 05:56:23 Voltage Offset Correction: v_off_ini = 0.000005563 V, v_off_fin = -0.000001628 V 05:56:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302819 Vs 05:56:26 Temperature Measurement, Probe Number = 0, T = 20.240000 C 05:56:27 Temperature Measurement, Probe Number = 1, T = 20.027000 C 05:56:28 Temperature Measurement, Probe Number = 2, T = 19.998000 C 05:56:28 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:56:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:56:29 Integrated Voltage Measurement... 05:56:47 Voltage Offset Correction: v_off_ini = 0.000002090 V, v_off_fin = 0.000006506 V 05:56:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432663 Vs 05:56:48 Integrated Voltage Measurement... 05:57:07 Voltage Offset Correction: v_off_ini = 0.000005944 V, v_off_fin = -0.000000703 V 05:57:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303308 Vs 05:57:10 Temperature Measurement, Probe Number = 0, T = 20.228000 C 05:57:11 Temperature Measurement, Probe Number = 1, T = 20.026000 C 05:57:12 Temperature Measurement, Probe Number = 2, T = 19.999000 C 05:57:12 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:57:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:57:12 Integrated Voltage Measurement... 05:57:32 Voltage Offset Correction: v_off_ini = 0.000002304 V, v_off_fin = 0.000006135 V 05:57:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444944 Vs 05:57:33 Integrated Voltage Measurement... 05:57:52 Voltage Offset Correction: v_off_ini = 0.000005884 V, v_off_fin = -0.000001478 V 05:57:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309990 Vs 05:57:55 Temperature Measurement, Probe Number = 0, T = 20.258000 C 05:57:56 Temperature Measurement, Probe Number = 1, T = 20.026000 C 05:57:56 Temperature Measurement, Probe Number = 2, T = 19.997000 C 05:57:57 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:57:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:57:57 Integrated Voltage Measurement... 05:58:16 Voltage Offset Correction: v_off_ini = 0.000001932 V, v_off_fin = 0.000006674 V 05:58:17 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434401 Vs 05:58:17 Integrated Voltage Measurement... 05:58:36 Voltage Offset Correction: v_off_ini = 0.000005845 V, v_off_fin = -0.000001899 V 05:58:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312015 Vs 05:58:39 Temperature Measurement, Probe Number = 0, T = 20.263000 C 05:58:40 Temperature Measurement, Probe Number = 1, T = 20.026000 C 05:58:40 Temperature Measurement, Probe Number = 2, T = 19.995000 C 05:58:41 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:58:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:58:41 Integrated Voltage Measurement... 05:59:00 Voltage Offset Correction: v_off_ini = 0.000002127 V, v_off_fin = 0.000006036 V 05:59:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427963 Vs 05:59:01 Integrated Voltage Measurement... 05:59:20 Voltage Offset Correction: v_off_ini = 0.000005647 V, v_off_fin = -0.000002098 V 05:59:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315831 Vs 05:59:23 Temperature Measurement, Probe Number = 0, T = 20.242000 C 05:59:24 Temperature Measurement, Probe Number = 1, T = 20.026000 C 05:59:25 Temperature Measurement, Probe Number = 2, T = 19.997000 C 05:59:25 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:59:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:59:25 Integrated Voltage Measurement... 05:59:45 Voltage Offset Correction: v_off_ini = 0.000002172 V, v_off_fin = 0.000006611 V 05:59:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434534 Vs 05:59:45 Integrated Voltage Measurement... 06:00:05 Voltage Offset Correction: v_off_ini = 0.000005836 V, v_off_fin = -0.000000717 V 06:00:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301514 Vs 06:30:07 Temperature Measurement, Probe Number = 0, T = 20.279000 C 06:30:08 Temperature Measurement, Probe Number = 1, T = 20.027000 C 06:30:09 Temperature Measurement, Probe Number = 2, T = 20.002000 C 06:30:10 Temperature Measurement, Probe Number = 3, T = 19.975000 C 06:30:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 06:30:10 Integrated Voltage Measurement... 06:30:29 Voltage Offset Correction: v_off_ini = 0.000003390 V, v_off_fin = 0.000006502 V 06:30:29 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175523589 Vs 06:30:30 Integrated Voltage Measurement... 06:30:48 Voltage Offset Correction: v_off_ini = 0.000005423 V, v_off_fin = -0.000002510 V 06:30:49 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175304164 Vs 06:30:51 Temperature Measurement, Probe Number = 0, T = 20.281000 C 06:30:52 Temperature Measurement, Probe Number = 1, T = 20.025000 C 06:30:53 Temperature Measurement, Probe Number = 2, T = 19.998000 C 06:30:53 Temperature Measurement, Probe Number = 3, T = 19.972000 C 06:30:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 06:30:54 Integrated Voltage Measurement... 06:31:13 Voltage Offset Correction: v_off_ini = 0.000001950 V, v_off_fin = 0.000006556 V 06:31:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433403 Vs 06:31:13 Integrated Voltage Measurement... 06:31:34 Voltage Offset Correction: v_off_ini = 0.000005732 V, v_off_fin = 0.000000119 V 06:31:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310806 Vs 06:31:37 Temperature Measurement, Probe Number = 0, T = 20.245000 C 06:31:37 Temperature Measurement, Probe Number = 1, T = 20.021000 C 06:31:38 Temperature Measurement, Probe Number = 2, T = 19.997000 C 06:31:39 Temperature Measurement, Probe Number = 3, T = 19.969000 C 06:31:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 06:31:39 Integrated Voltage Measurement... 06:31:58 Voltage Offset Correction: v_off_ini = 0.000002133 V, v_off_fin = 0.000006263 V 06:31:59 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175425523 Vs 06:31:59 Integrated Voltage Measurement... 06:32:18 Voltage Offset Correction: v_off_ini = 0.000005419 V, v_off_fin = -0.000002076 V 06:32:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306281 Vs 06:32:21 Temperature Measurement, Probe Number = 0, T = 20.206000 C 06:32:22 Temperature Measurement, Probe Number = 1, T = 20.023000 C 06:32:22 Temperature Measurement, Probe Number = 2, T = 20.000000 C 06:32:23 Temperature Measurement, Probe Number = 3, T = 19.972000 C 06:32:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 06:32:23 Integrated Voltage Measurement... 06:32:43 Voltage Offset Correction: v_off_ini = 0.000001615 V, v_off_fin = 0.000006280 V 06:32:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435397 Vs 06:32:43 Integrated Voltage Measurement... 06:33:02 Voltage Offset Correction: v_off_ini = 0.000005400 V, v_off_fin = -0.000001491 V 06:33:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313320 Vs 06:33:05 Temperature Measurement, Probe Number = 0, T = 20.246000 C 06:33:06 Temperature Measurement, Probe Number = 1, T = 20.027000 C 06:33:07 Temperature Measurement, Probe Number = 2, T = 20.002000 C 06:33:07 Temperature Measurement, Probe Number = 3, T = 19.976000 C 06:33:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 06:33:08 Integrated Voltage Measurement... 06:33:27 Voltage Offset Correction: v_off_ini = 0.000001538 V, v_off_fin = 0.000006499 V 06:33:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437442 Vs 06:33:27 Integrated Voltage Measurement... 06:33:47 Voltage Offset Correction: v_off_ini = 0.000005214 V, v_off_fin = -0.000002051 V 06:33:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313599 Vs 06:33:49 Temperature Measurement, Probe Number = 0, T = 20.283000 C 06:33:50 Temperature Measurement, Probe Number = 1, T = 20.028000 C 06:33:51 Temperature Measurement, Probe Number = 2, T = 20.004000 C 06:33:51 Temperature Measurement, Probe Number = 3, T = 19.977000 C 06:33:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 06:33:52 Integrated Voltage Measurement... 06:34:11 Voltage Offset Correction: v_off_ini = 0.000002484 V, v_off_fin = 0.000006666 V 06:34:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442630 Vs 06:34:11 Integrated Voltage Measurement... 06:34:30 Voltage Offset Correction: v_off_ini = 0.000005943 V, v_off_fin = -0.000002343 V 06:34:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301431 Vs 06:34:33 Temperature Measurement, Probe Number = 0, T = 20.308000 C 06:34:34 Temperature Measurement, Probe Number = 1, T = 20.026000 C 06:34:35 Temperature Measurement, Probe Number = 2, T = 20.001000 C 06:34:35 Temperature Measurement, Probe Number = 3, T = 19.973000 C 06:34:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 06:34:36 Integrated Voltage Measurement... 06:34:55 Voltage Offset Correction: v_off_ini = 0.000002519 V, v_off_fin = 0.000006573 V 06:34:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437886 Vs 06:34:55 Integrated Voltage Measurement... 06:35:15 Voltage Offset Correction: v_off_ini = 0.000005768 V, v_off_fin = -0.000001995 V 06:35:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312107 Vs 06:35:17 Temperature Measurement, Probe Number = 0, T = 20.313000 C 06:35:18 Temperature Measurement, Probe Number = 1, T = 20.027000 C 06:35:19 Temperature Measurement, Probe Number = 2, T = 20.000000 C 06:35:20 Temperature Measurement, Probe Number = 3, T = 19.976000 C 06:35:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 06:35:20 Integrated Voltage Measurement... 06:35:39 Voltage Offset Correction: v_off_ini = 0.000001826 V, v_off_fin = 0.000006587 V 06:35:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437421 Vs 06:35:39 Integrated Voltage Measurement... 06:35:59 Voltage Offset Correction: v_off_ini = 0.000005771 V, v_off_fin = -0.000001095 V 06:35:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317883 Vs 06:36:02 Temperature Measurement, Probe Number = 0, T = 20.286000 C 06:36:02 Temperature Measurement, Probe Number = 1, T = 20.026000 C 06:36:03 Temperature Measurement, Probe Number = 2, T = 19.998000 C 06:36:04 Temperature Measurement, Probe Number = 3, T = 19.975000 C 06:36:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 06:36:04 Integrated Voltage Measurement... 06:36:23 Voltage Offset Correction: v_off_ini = 0.000002085 V, v_off_fin = 0.000006014 V 06:36:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435825 Vs 06:36:23 Integrated Voltage Measurement... 06:36:43 Voltage Offset Correction: v_off_ini = 0.000005774 V, v_off_fin = -0.000001659 V 06:36:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311800 Vs 06:36:46 Temperature Measurement, Probe Number = 0, T = 20.193000 C 06:36:47 Temperature Measurement, Probe Number = 1, T = 20.024000 C 06:36:47 Temperature Measurement, Probe Number = 2, T = 19.997000 C 06:36:48 Temperature Measurement, Probe Number = 3, T = 19.970000 C 06:36:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 06:36:48 Integrated Voltage Measurement... 06:37:07 Voltage Offset Correction: v_off_ini = 0.000001964 V, v_off_fin = 0.000006526 V 06:37:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438890 Vs 06:37:07 Integrated Voltage Measurement... 06:37:27 Voltage Offset Correction: v_off_ini = 0.000006086 V, v_off_fin = -0.000001586 V 06:37:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311595 Vs 07:07:30 Temperature Measurement, Probe Number = 0, T = 20.147000 C 07:07:31 Temperature Measurement, Probe Number = 1, T = 20.023000 C 07:07:31 Temperature Measurement, Probe Number = 2, T = 19.993000 C 07:07:32 Temperature Measurement, Probe Number = 3, T = 19.969000 C 07:07:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 07:07:32 Integrated Voltage Measurement... 07:07:52 Voltage Offset Correction: v_off_ini = 0.000004515 V, v_off_fin = 0.000006629 V 07:07:52 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175535787 Vs 07:07:52 Integrated Voltage Measurement... 07:08:12 Voltage Offset Correction: v_off_ini = 0.000006129 V, v_off_fin = -0.000002404 V 07:08:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307423 Vs 07:08:15 Temperature Measurement, Probe Number = 0, T = 20.124000 C 07:08:15 Temperature Measurement, Probe Number = 1, T = 20.025000 C 07:08:16 Temperature Measurement, Probe Number = 2, T = 19.997000 C 07:08:17 Temperature Measurement, Probe Number = 3, T = 19.971000 C 07:08:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:08:17 Integrated Voltage Measurement... 07:08:36 Voltage Offset Correction: v_off_ini = 0.000001184 V, v_off_fin = 0.000006473 V 07:08:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435653 Vs 07:08:37 Integrated Voltage Measurement... 07:08:56 Voltage Offset Correction: v_off_ini = 0.000005697 V, v_off_fin = -0.000002216 V 07:08:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303809 Vs 07:08:59 Temperature Measurement, Probe Number = 0, T = 20.141000 C 07:09:00 Temperature Measurement, Probe Number = 1, T = 20.026000 C 07:09:00 Temperature Measurement, Probe Number = 2, T = 19.999000 C 07:09:01 Temperature Measurement, Probe Number = 3, T = 19.971000 C 07:09:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:09:01 Integrated Voltage Measurement... 07:09:20 Voltage Offset Correction: v_off_ini = 0.000000600 V, v_off_fin = 0.000006613 V 07:09:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439043 Vs 07:09:21 Integrated Voltage Measurement... 07:09:40 Voltage Offset Correction: v_off_ini = 0.000005826 V, v_off_fin = -0.000001656 V 07:09:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306179 Vs 07:09:43 Temperature Measurement, Probe Number = 0, T = 20.183000 C 07:09:44 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:09:44 Temperature Measurement, Probe Number = 2, T = 20.000000 C 07:09:45 Temperature Measurement, Probe Number = 3, T = 19.973000 C 07:09:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:09:45 Integrated Voltage Measurement... 07:10:04 Voltage Offset Correction: v_off_ini = 0.000002307 V, v_off_fin = 0.000006483 V 07:10:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438394 Vs 07:10:04 Integrated Voltage Measurement... 07:10:24 Voltage Offset Correction: v_off_ini = 0.000006101 V, v_off_fin = -0.000001946 V 07:10:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307779 Vs 07:10:27 Temperature Measurement, Probe Number = 0, T = 20.249000 C 07:10:27 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:10:28 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:10:29 Temperature Measurement, Probe Number = 3, T = 19.973000 C 07:10:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:10:29 Integrated Voltage Measurement... 07:10:48 Voltage Offset Correction: v_off_ini = 0.000001539 V, v_off_fin = 0.000007389 V 07:10:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444947 Vs 07:10:49 Integrated Voltage Measurement... 07:11:08 Voltage Offset Correction: v_off_ini = 0.000006263 V, v_off_fin = -0.000001507 V 07:11:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306338 Vs 07:11:11 Temperature Measurement, Probe Number = 0, T = 20.250000 C 07:11:12 Temperature Measurement, Probe Number = 1, T = 20.026000 C 07:11:12 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:11:13 Temperature Measurement, Probe Number = 3, T = 19.971000 C 07:11:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:11:13 Integrated Voltage Measurement... 07:11:32 Voltage Offset Correction: v_off_ini = 0.000003112 V, v_off_fin = 0.000006696 V 07:11:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442050 Vs 07:11:33 Integrated Voltage Measurement... 07:11:52 Voltage Offset Correction: v_off_ini = 0.000005705 V, v_off_fin = -0.000001359 V 07:11:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304557 Vs 07:11:55 Temperature Measurement, Probe Number = 0, T = 20.254000 C 07:11:56 Temperature Measurement, Probe Number = 1, T = 20.025000 C 07:11:56 Temperature Measurement, Probe Number = 2, T = 20.001000 C 07:11:57 Temperature Measurement, Probe Number = 3, T = 19.971000 C 07:11:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:11:57 Integrated Voltage Measurement... 07:12:16 Voltage Offset Correction: v_off_ini = 0.000001498 V, v_off_fin = 0.000006327 V 07:12:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437511 Vs 07:12:17 Integrated Voltage Measurement... 07:12:35 Voltage Offset Correction: v_off_ini = 0.000005596 V, v_off_fin = -0.000002692 V 07:12:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314073 Vs 07:12:38 Temperature Measurement, Probe Number = 0, T = 20.233000 C 07:12:39 Temperature Measurement, Probe Number = 1, T = 20.026000 C 07:12:40 Temperature Measurement, Probe Number = 2, T = 20.001000 C 07:12:40 Temperature Measurement, Probe Number = 3, T = 19.973000 C 07:12:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:12:41 Integrated Voltage Measurement... 07:13:00 Voltage Offset Correction: v_off_ini = 0.000001377 V, v_off_fin = 0.000005945 V 07:13:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438114 Vs 07:13:00 Integrated Voltage Measurement... 07:13:20 Voltage Offset Correction: v_off_ini = 0.000005829 V, v_off_fin = -0.000000798 V 07:13:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308991 Vs 07:13:23 Temperature Measurement, Probe Number = 0, T = 20.248000 C 07:13:24 Temperature Measurement, Probe Number = 1, T = 20.028000 C 07:13:24 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:13:25 Temperature Measurement, Probe Number = 3, T = 19.976000 C 07:13:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:13:25 Integrated Voltage Measurement... 07:13:44 Voltage Offset Correction: v_off_ini = 0.000002168 V, v_off_fin = 0.000006247 V 07:13:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175424785 Vs 07:13:45 Integrated Voltage Measurement... 07:14:05 Voltage Offset Correction: v_off_ini = 0.000006037 V, v_off_fin = -0.000000924 V 07:14:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309750 Vs 07:14:08 Temperature Measurement, Probe Number = 0, T = 20.275000 C 07:14:09 Temperature Measurement, Probe Number = 1, T = 20.026000 C 07:14:09 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:14:10 Temperature Measurement, Probe Number = 3, T = 19.972000 C 07:14:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:14:10 Integrated Voltage Measurement... 07:14:30 Voltage Offset Correction: v_off_ini = 0.000002039 V, v_off_fin = 0.000006412 V 07:14:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175427779 Vs 07:14:30 Integrated Voltage Measurement... 07:14:49 Voltage Offset Correction: v_off_ini = 0.000005763 V, v_off_fin = -0.000000957 V 07:14:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301125 Vs 07:44:52 Temperature Measurement, Probe Number = 0, T = 20.243000 C 07:44:53 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:44:54 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:44:54 Temperature Measurement, Probe Number = 3, T = 19.975000 C 07:44:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:44:54 Integrated Voltage Measurement... 07:45:14 Voltage Offset Correction: v_off_ini = 0.000003573 V, v_off_fin = 0.000006661 V 07:45:14 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175529765 Vs 07:45:14 Integrated Voltage Measurement... 07:45:33 Voltage Offset Correction: v_off_ini = 0.000006108 V, v_off_fin = -0.000001865 V 07:45:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309944 Vs 07:45:36 Temperature Measurement, Probe Number = 0, T = 20.282000 C 07:45:37 Temperature Measurement, Probe Number = 1, T = 20.031000 C 07:45:37 Temperature Measurement, Probe Number = 2, T = 20.007000 C 07:45:38 Temperature Measurement, Probe Number = 3, T = 19.978000 C 07:45:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 07:45:38 Integrated Voltage Measurement... 07:45:58 Voltage Offset Correction: v_off_ini = 0.000001768 V, v_off_fin = 0.000006298 V 07:45:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432375 Vs 07:45:58 Integrated Voltage Measurement... 07:46:17 Voltage Offset Correction: v_off_ini = 0.000006093 V, v_off_fin = -0.000001761 V 07:46:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311289 Vs 07:46:20 Temperature Measurement, Probe Number = 0, T = 20.311000 C 07:46:21 Temperature Measurement, Probe Number = 1, T = 20.028000 C 07:46:21 Temperature Measurement, Probe Number = 2, T = 20.005000 C 07:46:22 Temperature Measurement, Probe Number = 3, T = 19.977000 C 07:46:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:46:22 Integrated Voltage Measurement... 07:46:41 Voltage Offset Correction: v_off_ini = 0.000001868 V, v_off_fin = 0.000007045 V 07:46:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442221 Vs 07:46:42 Integrated Voltage Measurement... 07:47:01 Voltage Offset Correction: v_off_ini = 0.000006435 V, v_off_fin = -0.000002253 V 07:47:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305642 Vs 07:47:04 Temperature Measurement, Probe Number = 0, T = 20.255000 C 07:47:04 Temperature Measurement, Probe Number = 1, T = 20.030000 C 07:47:05 Temperature Measurement, Probe Number = 2, T = 20.004000 C 07:47:06 Temperature Measurement, Probe Number = 3, T = 19.978000 C 07:47:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:47:06 Integrated Voltage Measurement... 07:47:25 Voltage Offset Correction: v_off_ini = 0.000001248 V, v_off_fin = 0.000005993 V 07:47:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436144 Vs 07:47:26 Integrated Voltage Measurement... 07:47:45 Voltage Offset Correction: v_off_ini = 0.000005397 V, v_off_fin = -0.000002659 V 07:47:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310597 Vs 07:47:48 Temperature Measurement, Probe Number = 0, T = 20.248000 C 07:47:48 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:47:49 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:47:50 Temperature Measurement, Probe Number = 3, T = 19.977000 C 07:47:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:47:50 Integrated Voltage Measurement... 07:48:09 Voltage Offset Correction: v_off_ini = 0.000000819 V, v_off_fin = 0.000006536 V 07:48:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442061 Vs 07:48:10 Integrated Voltage Measurement... 07:48:29 Voltage Offset Correction: v_off_ini = 0.000005489 V, v_off_fin = -0.000002482 V 07:48:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315587 Vs 07:48:32 Temperature Measurement, Probe Number = 0, T = 20.255000 C 07:48:33 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:48:34 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:48:34 Temperature Measurement, Probe Number = 3, T = 19.977000 C 07:48:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:48:35 Integrated Voltage Measurement... 07:48:54 Voltage Offset Correction: v_off_ini = 0.000002238 V, v_off_fin = 0.000007028 V 07:48:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438300 Vs 07:48:54 Integrated Voltage Measurement... 07:49:14 Voltage Offset Correction: v_off_ini = 0.000005868 V, v_off_fin = -0.000001587 V 07:49:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306852 Vs 07:49:16 Temperature Measurement, Probe Number = 0, T = 20.296000 C 07:49:17 Temperature Measurement, Probe Number = 1, T = 20.031000 C 07:49:18 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:49:18 Temperature Measurement, Probe Number = 3, T = 19.976000 C 07:49:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:49:19 Integrated Voltage Measurement... 07:49:38 Voltage Offset Correction: v_off_ini = 0.000002544 V, v_off_fin = 0.000006418 V 07:49:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437912 Vs 07:49:38 Integrated Voltage Measurement... 07:49:58 Voltage Offset Correction: v_off_ini = 0.000005484 V, v_off_fin = -0.000000682 V 07:49:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312721 Vs 07:50:01 Temperature Measurement, Probe Number = 0, T = 20.223000 C 07:50:01 Temperature Measurement, Probe Number = 1, T = 20.031000 C 07:50:02 Temperature Measurement, Probe Number = 2, T = 20.001000 C 07:50:03 Temperature Measurement, Probe Number = 3, T = 19.977000 C 07:50:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:50:03 Integrated Voltage Measurement... 07:50:22 Voltage Offset Correction: v_off_ini = 0.000001887 V, v_off_fin = 0.000006590 V 07:50:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431524 Vs 07:50:23 Integrated Voltage Measurement... 07:50:42 Voltage Offset Correction: v_off_ini = 0.000005477 V, v_off_fin = -0.000001994 V 07:50:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316939 Vs 07:50:45 Temperature Measurement, Probe Number = 0, T = 20.241000 C 07:50:46 Temperature Measurement, Probe Number = 1, T = 20.028000 C 07:50:46 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:50:47 Temperature Measurement, Probe Number = 3, T = 19.976000 C 07:50:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 07:50:47 Integrated Voltage Measurement... 07:51:06 Voltage Offset Correction: v_off_ini = 0.000002458 V, v_off_fin = 0.000006274 V 07:51:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437379 Vs 07:51:07 Integrated Voltage Measurement... 07:51:26 Voltage Offset Correction: v_off_ini = 0.000005211 V, v_off_fin = -0.000003246 V 07:51:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318986 Vs 07:51:29 Temperature Measurement, Probe Number = 0, T = 20.269000 C 07:51:29 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:51:30 Temperature Measurement, Probe Number = 2, T = 19.997000 C 07:51:31 Temperature Measurement, Probe Number = 3, T = 19.971000 C 07:51:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:51:31 Integrated Voltage Measurement... 07:51:50 Voltage Offset Correction: v_off_ini = 0.000002430 V, v_off_fin = 0.000007034 V 07:51:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438926 Vs 07:51:50 Integrated Voltage Measurement... 07:52:10 Voltage Offset Correction: v_off_ini = 0.000005895 V, v_off_fin = -0.000001613 V 07:52:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309755 Vs 08:22:13 Temperature Measurement, Probe Number = 0, T = 20.191000 C 08:22:14 Temperature Measurement, Probe Number = 1, T = 20.029000 C 08:22:14 Temperature Measurement, Probe Number = 2, T = 20.002000 C 08:22:15 Temperature Measurement, Probe Number = 3, T = 19.973000 C 08:22:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:22:15 Integrated Voltage Measurement... 08:22:34 Voltage Offset Correction: v_off_ini = 0.000004527 V, v_off_fin = 0.000006941 V 08:22:34 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175531911 Vs 08:22:35 Integrated Voltage Measurement... 08:22:54 Voltage Offset Correction: v_off_ini = 0.000005824 V, v_off_fin = -0.000001215 V 08:22:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310383 Vs 08:22:57 Temperature Measurement, Probe Number = 0, T = 20.166000 C 08:22:57 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:22:58 Temperature Measurement, Probe Number = 2, T = 20.005000 C 08:22:59 Temperature Measurement, Probe Number = 3, T = 19.978000 C 08:22:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 08:22:59 Integrated Voltage Measurement... 08:23:19 Voltage Offset Correction: v_off_ini = 0.000001443 V, v_off_fin = 0.000005732 V 08:23:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436442 Vs 08:23:19 Integrated Voltage Measurement... 08:23:39 Voltage Offset Correction: v_off_ini = 0.000005315 V, v_off_fin = -0.000001964 V 08:23:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308912 Vs 08:23:42 Temperature Measurement, Probe Number = 0, T = 20.275000 C 08:23:43 Temperature Measurement, Probe Number = 1, T = 20.037000 C 08:23:43 Temperature Measurement, Probe Number = 2, T = 20.008000 C 08:23:44 Temperature Measurement, Probe Number = 3, T = 19.978000 C 08:23:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:23:44 Integrated Voltage Measurement... 08:24:03 Voltage Offset Correction: v_off_ini = 0.000001350 V, v_off_fin = 0.000006422 V 08:24:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434414 Vs 08:24:03 Integrated Voltage Measurement... 08:24:23 Voltage Offset Correction: v_off_ini = 0.000005380 V, v_off_fin = -0.000002109 V 08:24:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312133 Vs 08:24:26 Temperature Measurement, Probe Number = 0, T = 20.329000 C 08:24:27 Temperature Measurement, Probe Number = 1, T = 20.036000 C 08:24:27 Temperature Measurement, Probe Number = 2, T = 20.011000 C 08:24:28 Temperature Measurement, Probe Number = 3, T = 19.977000 C 08:24:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:24:28 Integrated Voltage Measurement... 08:24:47 Voltage Offset Correction: v_off_ini = 0.000002187 V, v_off_fin = 0.000006461 V 08:24:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438262 Vs 08:24:47 Integrated Voltage Measurement... 08:25:07 Voltage Offset Correction: v_off_ini = 0.000005533 V, v_off_fin = -0.000002498 V 08:25:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314454 Vs 08:25:10 Temperature Measurement, Probe Number = 0, T = 20.302000 C 08:25:10 Temperature Measurement, Probe Number = 1, T = 20.037000 C 08:25:11 Temperature Measurement, Probe Number = 2, T = 20.011000 C 08:25:12 Temperature Measurement, Probe Number = 3, T = 19.979000 C 08:25:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:25:12 Integrated Voltage Measurement... 08:25:31 Voltage Offset Correction: v_off_ini = 0.000001965 V, v_off_fin = 0.000006959 V 08:25:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440351 Vs 08:25:32 Integrated Voltage Measurement... 08:25:51 Voltage Offset Correction: v_off_ini = 0.000005850 V, v_off_fin = -0.000001476 V 08:25:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315413 Vs 08:25:54 Temperature Measurement, Probe Number = 0, T = 20.282000 C 08:25:54 Temperature Measurement, Probe Number = 1, T = 20.033000 C 08:25:55 Temperature Measurement, Probe Number = 2, T = 20.005000 C 08:25:56 Temperature Measurement, Probe Number = 3, T = 19.975000 C 08:25:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 08:25:56 Integrated Voltage Measurement... 08:26:15 Voltage Offset Correction: v_off_ini = 0.000002305 V, v_off_fin = 0.000007033 V 08:26:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445931 Vs 08:26:16 Integrated Voltage Measurement... 08:26:35 Voltage Offset Correction: v_off_ini = 0.000005816 V, v_off_fin = -0.000001608 V 08:26:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311165 Vs 08:26:38 Temperature Measurement, Probe Number = 0, T = 20.264000 C 08:26:39 Temperature Measurement, Probe Number = 1, T = 20.029000 C 08:26:39 Temperature Measurement, Probe Number = 2, T = 20.003000 C 08:26:40 Temperature Measurement, Probe Number = 3, T = 19.973000 C 08:26:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:26:40 Integrated Voltage Measurement... 08:26:59 Voltage Offset Correction: v_off_ini = 0.000002457 V, v_off_fin = 0.000007026 V 08:27:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443204 Vs 08:27:00 Integrated Voltage Measurement... 08:27:19 Voltage Offset Correction: v_off_ini = 0.000006277 V, v_off_fin = -0.000000679 V 08:27:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305998 Vs 08:27:22 Temperature Measurement, Probe Number = 0, T = 20.214000 C 08:27:23 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:27:23 Temperature Measurement, Probe Number = 2, T = 20.008000 C 08:27:24 Temperature Measurement, Probe Number = 3, T = 19.976000 C 08:27:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:27:24 Integrated Voltage Measurement... 08:27:43 Voltage Offset Correction: v_off_ini = 0.000001370 V, v_off_fin = 0.000006763 V 08:27:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175449763 Vs 08:27:44 Integrated Voltage Measurement... 08:28:03 Voltage Offset Correction: v_off_ini = 0.000005516 V, v_off_fin = -0.000002210 V 08:28:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313234 Vs 08:28:06 Temperature Measurement, Probe Number = 0, T = 20.302000 C 08:28:07 Temperature Measurement, Probe Number = 1, T = 20.033000 C 08:28:08 Temperature Measurement, Probe Number = 2, T = 20.008000 C 08:28:08 Temperature Measurement, Probe Number = 3, T = 19.976000 C 08:28:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:28:08 Integrated Voltage Measurement... 08:28:28 Voltage Offset Correction: v_off_ini = 0.000001726 V, v_off_fin = 0.000006462 V 08:28:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440693 Vs 08:28:28 Integrated Voltage Measurement... 08:28:47 Voltage Offset Correction: v_off_ini = 0.000004887 V, v_off_fin = -0.000002049 V 08:28:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314413 Vs 08:28:50 Temperature Measurement, Probe Number = 0, T = 20.305000 C 08:28:51 Temperature Measurement, Probe Number = 1, T = 20.031000 C 08:28:52 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:28:52 Temperature Measurement, Probe Number = 3, T = 19.976000 C 08:28:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:28:53 Integrated Voltage Measurement... 08:29:12 Voltage Offset Correction: v_off_ini = 0.000001820 V, v_off_fin = 0.000006193 V 08:29:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435887 Vs 08:29:12 Integrated Voltage Measurement... 08:29:31 Voltage Offset Correction: v_off_ini = 0.000005183 V, v_off_fin = -0.000001819 V 08:29:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313772 Vs 08:59:34 Temperature Measurement, Probe Number = 0, T = 20.307000 C 08:59:35 Temperature Measurement, Probe Number = 1, T = 20.037000 C 08:59:36 Temperature Measurement, Probe Number = 2, T = 20.009000 C 08:59:36 Temperature Measurement, Probe Number = 3, T = 19.979000 C 08:59:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 08:59:36 Integrated Voltage Measurement... 08:59:55 Voltage Offset Correction: v_off_ini = 0.000004797 V, v_off_fin = 0.000006599 V 08:59:56 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175541978 Vs 08:59:56 Integrated Voltage Measurement... 09:00:15 Voltage Offset Correction: v_off_ini = 0.000006216 V, v_off_fin = -0.000002256 V 09:00:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313807 Vs 09:00:18 Temperature Measurement, Probe Number = 0, T = 20.299000 C 09:00:19 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:00:19 Temperature Measurement, Probe Number = 2, T = 20.016000 C 09:00:20 Temperature Measurement, Probe Number = 3, T = 19.980000 C 09:00:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:00:20 Integrated Voltage Measurement... 09:00:39 Voltage Offset Correction: v_off_ini = 0.000001092 V, v_off_fin = 0.000006263 V 09:00:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434983 Vs 09:00:40 Integrated Voltage Measurement... 09:00:59 Voltage Offset Correction: v_off_ini = 0.000005226 V, v_off_fin = -0.000002601 V 09:00:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314242 Vs 09:01:02 Temperature Measurement, Probe Number = 0, T = 20.316000 C 09:01:02 Temperature Measurement, Probe Number = 1, T = 20.041000 C 09:01:03 Temperature Measurement, Probe Number = 2, T = 20.016000 C 09:01:04 Temperature Measurement, Probe Number = 3, T = 19.984000 C 09:01:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:01:04 Integrated Voltage Measurement... 09:01:23 Voltage Offset Correction: v_off_ini = 0.000001028 V, v_off_fin = 0.000005970 V 09:01:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435554 Vs 09:01:24 Integrated Voltage Measurement... 09:01:44 Voltage Offset Correction: v_off_ini = 0.000005486 V, v_off_fin = -0.000000361 V 09:01:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309484 Vs 09:01:47 Temperature Measurement, Probe Number = 0, T = 20.330000 C 09:01:48 Temperature Measurement, Probe Number = 1, T = 20.040000 C 09:01:48 Temperature Measurement, Probe Number = 2, T = 20.018000 C 09:01:49 Temperature Measurement, Probe Number = 3, T = 19.982000 C 09:01:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:01:49 Integrated Voltage Measurement... 09:02:09 Voltage Offset Correction: v_off_ini = 0.000001980 V, v_off_fin = 0.000006351 V 09:02:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175424426 Vs 09:02:09 Integrated Voltage Measurement... 09:02:29 Voltage Offset Correction: v_off_ini = 0.000005987 V, v_off_fin = -0.000001696 V 09:02:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316816 Vs 09:02:32 Temperature Measurement, Probe Number = 0, T = 20.338000 C 09:02:32 Temperature Measurement, Probe Number = 1, T = 20.040000 C 09:02:33 Temperature Measurement, Probe Number = 2, T = 20.018000 C 09:02:34 Temperature Measurement, Probe Number = 3, T = 19.984000 C 09:02:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:02:34 Integrated Voltage Measurement... 09:02:53 Voltage Offset Correction: v_off_ini = 0.000001908 V, v_off_fin = 0.000007085 V 09:02:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175441112 Vs 09:02:54 Integrated Voltage Measurement... 09:03:13 Voltage Offset Correction: v_off_ini = 0.000006306 V, v_off_fin = -0.000000991 V 09:03:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300047 Vs 09:03:16 Temperature Measurement, Probe Number = 0, T = 20.331000 C 09:03:17 Temperature Measurement, Probe Number = 1, T = 20.041000 C 09:03:17 Temperature Measurement, Probe Number = 2, T = 20.017000 C 09:03:18 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:03:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:03:18 Integrated Voltage Measurement... 09:03:37 Voltage Offset Correction: v_off_ini = 0.000002219 V, v_off_fin = 0.000006817 V 09:03:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175454574 Vs 09:03:38 Integrated Voltage Measurement... 09:03:58 Voltage Offset Correction: v_off_ini = 0.000005927 V, v_off_fin = -0.000000014 V 09:03:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310211 Vs 09:04:01 Temperature Measurement, Probe Number = 0, T = 20.338000 C 09:04:01 Temperature Measurement, Probe Number = 1, T = 20.040000 C 09:04:02 Temperature Measurement, Probe Number = 2, T = 20.014000 C 09:04:03 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:04:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:04:03 Integrated Voltage Measurement... 09:04:22 Voltage Offset Correction: v_off_ini = 0.000001940 V, v_off_fin = 0.000006936 V 09:04:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435141 Vs 09:04:22 Integrated Voltage Measurement... 09:04:42 Voltage Offset Correction: v_off_ini = 0.000006081 V, v_off_fin = -0.000001394 V 09:04:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306996 Vs 09:04:45 Temperature Measurement, Probe Number = 0, T = 20.323000 C 09:04:45 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:04:46 Temperature Measurement, Probe Number = 2, T = 20.013000 C 09:04:47 Temperature Measurement, Probe Number = 3, T = 19.978000 C 09:04:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:04:47 Integrated Voltage Measurement... 09:05:06 Voltage Offset Correction: v_off_ini = 0.000002527 V, v_off_fin = 0.000006840 V 09:05:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438806 Vs 09:05:06 Integrated Voltage Measurement... 09:05:26 Voltage Offset Correction: v_off_ini = 0.000006137 V, v_off_fin = -0.000001040 V 09:05:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303796 Vs 09:05:29 Temperature Measurement, Probe Number = 0, T = 20.329000 C 09:05:29 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:05:30 Temperature Measurement, Probe Number = 2, T = 20.016000 C 09:05:31 Temperature Measurement, Probe Number = 3, T = 19.984000 C 09:05:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:05:31 Integrated Voltage Measurement... 09:05:50 Voltage Offset Correction: v_off_ini = 0.000002027 V, v_off_fin = 0.000006555 V 09:05:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438514 Vs 09:05:50 Integrated Voltage Measurement... 09:06:10 Voltage Offset Correction: v_off_ini = 0.000005620 V, v_off_fin = -0.000001064 V 09:06:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311931 Vs 09:06:13 Temperature Measurement, Probe Number = 0, T = 20.332000 C 09:06:13 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:06:14 Temperature Measurement, Probe Number = 2, T = 20.015000 C 09:06:14 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:06:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:06:15 Integrated Voltage Measurement... 09:06:34 Voltage Offset Correction: v_off_ini = 0.000001639 V, v_off_fin = 0.000006667 V 09:06:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433907 Vs 09:06:34 Integrated Voltage Measurement... 09:06:54 Voltage Offset Correction: v_off_ini = 0.000005769 V, v_off_fin = -0.000000949 V 09:06:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309824 Vs 09:36:56 Temperature Measurement, Probe Number = 0, T = 20.269000 C 09:36:57 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:36:58 Temperature Measurement, Probe Number = 2, T = 20.014000 C 09:36:58 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:36:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:36:59 Integrated Voltage Measurement... 09:37:18 Voltage Offset Correction: v_off_ini = 0.000004428 V, v_off_fin = 0.000006563 V 09:37:18 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175533800 Vs 09:37:18 Integrated Voltage Measurement... 09:37:38 Voltage Offset Correction: v_off_ini = 0.000004988 V, v_off_fin = -0.000001872 V 09:37:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312567 Vs 09:37:41 Temperature Measurement, Probe Number = 0, T = 20.304000 C 09:37:42 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:37:42 Temperature Measurement, Probe Number = 2, T = 20.014000 C 09:37:43 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:37:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:37:43 Integrated Voltage Measurement... 09:38:03 Voltage Offset Correction: v_off_ini = 0.000002149 V, v_off_fin = 0.000006093 V 09:38:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440176 Vs 09:38:03 Integrated Voltage Measurement... 09:38:24 Voltage Offset Correction: v_off_ini = 0.000006128 V, v_off_fin = -0.000000613 V 09:38:24 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175308793 Vs 09:38:27 Temperature Measurement, Probe Number = 0, T = 20.299000 C 09:38:27 Temperature Measurement, Probe Number = 1, T = 20.040000 C 09:38:28 Temperature Measurement, Probe Number = 2, T = 20.012000 C 09:38:29 Temperature Measurement, Probe Number = 3, T = 19.981000 C 09:38:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:38:29 Integrated Voltage Measurement... 09:38:48 Voltage Offset Correction: v_off_ini = 0.000002119 V, v_off_fin = 0.000006895 V 09:38:48 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175427651 Vs 09:38:48 Integrated Voltage Measurement... 09:39:09 Voltage Offset Correction: v_off_ini = 0.000006091 V, v_off_fin = -0.000002327 V 09:39:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311937 Vs 09:39:12 Temperature Measurement, Probe Number = 0, T = 20.304000 C 09:39:13 Temperature Measurement, Probe Number = 1, T = 20.041000 C 09:39:13 Temperature Measurement, Probe Number = 2, T = 20.015000 C 09:39:14 Temperature Measurement, Probe Number = 3, T = 19.983000 C 09:39:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 09:39:14 Integrated Voltage Measurement... 09:39:34 Voltage Offset Correction: v_off_ini = 0.000002272 V, v_off_fin = 0.000006235 V 09:39:34 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175428956 Vs 09:39:34 Integrated Voltage Measurement... 09:39:53 Voltage Offset Correction: v_off_ini = 0.000006167 V, v_off_fin = -0.000001876 V 09:39:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308675 Vs 09:39:56 Temperature Measurement, Probe Number = 0, T = 20.324000 C 09:39:57 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:39:57 Temperature Measurement, Probe Number = 2, T = 20.013000 C 09:39:58 Temperature Measurement, Probe Number = 3, T = 19.980000 C 09:39:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:39:58 Integrated Voltage Measurement... 09:40:17 Voltage Offset Correction: v_off_ini = 0.000001519 V, v_off_fin = 0.000006634 V 09:40:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437341 Vs 09:40:18 Integrated Voltage Measurement... 09:40:37 Voltage Offset Correction: v_off_ini = 0.000005499 V, v_off_fin = -0.000001167 V 09:40:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310361 Vs 09:40:40 Temperature Measurement, Probe Number = 0, T = 20.309000 C 09:40:40 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:40:41 Temperature Measurement, Probe Number = 2, T = 20.013000 C 09:40:42 Temperature Measurement, Probe Number = 3, T = 19.985000 C 09:40:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 09:40:42 Integrated Voltage Measurement... 09:41:01 Voltage Offset Correction: v_off_ini = 0.000002439 V, v_off_fin = 0.000006572 V 09:41:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435231 Vs 09:41:02 Integrated Voltage Measurement... 09:41:21 Voltage Offset Correction: v_off_ini = 0.000005551 V, v_off_fin = -0.000002305 V 09:41:21 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175317376 Vs 09:41:24 Temperature Measurement, Probe Number = 0, T = 20.313000 C 09:41:25 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:41:25 Temperature Measurement, Probe Number = 2, T = 20.014000 C 09:41:26 Temperature Measurement, Probe Number = 3, T = 19.986000 C 09:41:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 09:41:26 Integrated Voltage Measurement... 09:41:46 Voltage Offset Correction: v_off_ini = 0.000001614 V, v_off_fin = 0.000006284 V 09:41:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443860 Vs 09:41:46 Integrated Voltage Measurement... 09:42:05 Voltage Offset Correction: v_off_ini = 0.000005264 V, v_off_fin = -0.000001195 V 09:42:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305785 Vs 09:42:08 Temperature Measurement, Probe Number = 0, T = 20.330000 C 09:42:09 Temperature Measurement, Probe Number = 1, T = 20.038000 C 09:42:09 Temperature Measurement, Probe Number = 2, T = 20.015000 C 09:42:10 Temperature Measurement, Probe Number = 3, T = 19.986000 C 09:42:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 09:42:10 Integrated Voltage Measurement... 09:42:29 Voltage Offset Correction: v_off_ini = 0.000002193 V, v_off_fin = 0.000006522 V 09:42:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438470 Vs 09:42:30 Integrated Voltage Measurement... 09:42:49 Voltage Offset Correction: v_off_ini = 0.000005746 V, v_off_fin = -0.000001069 V 09:42:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309161 Vs 09:42:52 Temperature Measurement, Probe Number = 0, T = 20.308000 C 09:42:53 Temperature Measurement, Probe Number = 1, T = 20.039000 C 09:42:53 Temperature Measurement, Probe Number = 2, T = 20.018000 C 09:42:54 Temperature Measurement, Probe Number = 3, T = 19.986000 C 09:42:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 09:42:54 Integrated Voltage Measurement... 09:43:13 Voltage Offset Correction: v_off_ini = 0.000001497 V, v_off_fin = 0.000007067 V 09:43:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433739 Vs 09:43:14 Integrated Voltage Measurement... 09:43:33 Voltage Offset Correction: v_off_ini = 0.000006131 V, v_off_fin = -0.000001326 V 09:43:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308228 Vs 09:43:36 Temperature Measurement, Probe Number = 0, T = 20.360000 C 09:43:37 Temperature Measurement, Probe Number = 1, T = 20.041000 C 09:43:37 Temperature Measurement, Probe Number = 2, T = 20.018000 C 09:43:38 Temperature Measurement, Probe Number = 3, T = 19.987000 C 09:43:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 09:43:38 Integrated Voltage Measurement... 09:43:57 Voltage Offset Correction: v_off_ini = 0.000001856 V, v_off_fin = 0.000007107 V 09:43:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443386 Vs 09:43:58 Integrated Voltage Measurement... 09:44:16 Voltage Offset Correction: v_off_ini = 0.000005953 V, v_off_fin = -0.000002211 V 09:44:17 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175303406 Vs 10:14:19 Temperature Measurement, Probe Number = 0, T = 20.360000 C 10:14:20 Temperature Measurement, Probe Number = 1, T = 20.046000 C 10:14:21 Temperature Measurement, Probe Number = 2, T = 20.022000 C 10:14:22 Temperature Measurement, Probe Number = 3, T = 19.989000 C 10:14:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:14:22 Integrated Voltage Measurement... 10:14:41 Voltage Offset Correction: v_off_ini = 0.000004451 V, v_off_fin = 0.000006827 V 10:14:42 Integrated Voltage Measurement Delta Gap = 0.0040036 m VT = 0.175549282 Vs 10:14:42 Integrated Voltage Measurement... 10:15:01 Voltage Offset Correction: v_off_ini = 0.000006100 V, v_off_fin = -0.000001210 V 10:15:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298542 Vs 10:15:04 Temperature Measurement, Probe Number = 0, T = 20.280000 C 10:15:05 Temperature Measurement, Probe Number = 1, T = 20.046000 C 10:15:05 Temperature Measurement, Probe Number = 2, T = 20.022000 C 10:15:06 Temperature Measurement, Probe Number = 3, T = 19.989000 C 10:15:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:15:06 Integrated Voltage Measurement... 10:15:25 Voltage Offset Correction: v_off_ini = 0.000002132 V, v_off_fin = 0.000006952 V 10:15:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434992 Vs 10:15:26 Integrated Voltage Measurement... 10:15:45 Voltage Offset Correction: v_off_ini = 0.000006041 V, v_off_fin = -0.000002634 V 10:15:45 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175312315 Vs 10:15:48 Temperature Measurement, Probe Number = 0, T = 20.292000 C 10:15:49 Temperature Measurement, Probe Number = 1, T = 20.049000 C 10:15:49 Temperature Measurement, Probe Number = 2, T = 20.026000 C 10:15:50 Temperature Measurement, Probe Number = 3, T = 19.990000 C 10:15:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:15:50 Integrated Voltage Measurement... 10:16:09 Voltage Offset Correction: v_off_ini = 0.000001458 V, v_off_fin = 0.000006527 V 10:16:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440119 Vs 10:16:10 Integrated Voltage Measurement... 10:16:29 Voltage Offset Correction: v_off_ini = 0.000005236 V, v_off_fin = -0.000002546 V 10:16:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310886 Vs 10:16:32 Temperature Measurement, Probe Number = 0, T = 20.257000 C 10:16:33 Temperature Measurement, Probe Number = 1, T = 20.051000 C 10:16:33 Temperature Measurement, Probe Number = 2, T = 20.025000 C 10:16:34 Temperature Measurement, Probe Number = 3, T = 19.994000 C 10:16:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:16:34 Integrated Voltage Measurement... 10:16:53 Voltage Offset Correction: v_off_ini = 0.000002205 V, v_off_fin = 0.000007075 V 10:16:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433145 Vs 10:16:54 Integrated Voltage Measurement... 10:17:13 Voltage Offset Correction: v_off_ini = 0.000005565 V, v_off_fin = -0.000001926 V 10:17:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313137 Vs 10:17:16 Temperature Measurement, Probe Number = 0, T = 20.336000 C 10:17:17 Temperature Measurement, Probe Number = 1, T = 20.053000 C 10:17:17 Temperature Measurement, Probe Number = 2, T = 20.027000 C 10:17:18 Temperature Measurement, Probe Number = 3, T = 19.993000 C 10:17:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:17:18 Integrated Voltage Measurement... 10:17:38 Voltage Offset Correction: v_off_ini = 0.000001920 V, v_off_fin = 0.000006918 V 10:17:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441941 Vs 10:17:38 Integrated Voltage Measurement... 10:17:57 Voltage Offset Correction: v_off_ini = 0.000005896 V, v_off_fin = -0.000002016 V 10:17:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309849 Vs 10:18:00 Temperature Measurement, Probe Number = 0, T = 20.334000 C 10:18:01 Temperature Measurement, Probe Number = 1, T = 20.049000 C 10:18:01 Temperature Measurement, Probe Number = 2, T = 20.026000 C 10:18:02 Temperature Measurement, Probe Number = 3, T = 19.990000 C 10:18:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:18:02 Integrated Voltage Measurement... 10:18:22 Voltage Offset Correction: v_off_ini = 0.000003283 V, v_off_fin = 0.000007055 V 10:18:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175447106 Vs 10:18:22 Integrated Voltage Measurement... 10:18:41 Voltage Offset Correction: v_off_ini = 0.000006584 V, v_off_fin = -0.000001885 V 10:18:41 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175295907 Vs 10:18:43 Temperature Measurement, Probe Number = 0, T = 20.343000 C 10:18:44 Temperature Measurement, Probe Number = 1, T = 20.048000 C 10:18:45 Temperature Measurement, Probe Number = 2, T = 20.025000 C 10:18:45 Temperature Measurement, Probe Number = 3, T = 19.989000 C 10:18:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:18:46 Integrated Voltage Measurement... 10:19:05 Voltage Offset Correction: v_off_ini = 0.000002282 V, v_off_fin = 0.000006994 V 10:19:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175444748 Vs 10:19:05 Integrated Voltage Measurement... 10:19:24 Voltage Offset Correction: v_off_ini = 0.000006402 V, v_off_fin = -0.000001881 V 10:19:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307951 Vs 10:19:27 Temperature Measurement, Probe Number = 0, T = 20.418000 C 10:19:28 Temperature Measurement, Probe Number = 1, T = 20.048000 C 10:19:28 Temperature Measurement, Probe Number = 2, T = 20.022000 C 10:19:29 Temperature Measurement, Probe Number = 3, T = 19.990000 C 10:19:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:19:29 Integrated Voltage Measurement... 10:19:49 Voltage Offset Correction: v_off_ini = 0.000001925 V, v_off_fin = 0.000006814 V 10:19:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433808 Vs 10:19:49 Integrated Voltage Measurement... 10:20:08 Voltage Offset Correction: v_off_ini = 0.000005841 V, v_off_fin = -0.000002139 V 10:20:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302632 Vs 10:20:11 Temperature Measurement, Probe Number = 0, T = 20.412000 C 10:20:11 Temperature Measurement, Probe Number = 1, T = 20.050000 C 10:20:12 Temperature Measurement, Probe Number = 2, T = 20.022000 C 10:20:13 Temperature Measurement, Probe Number = 3, T = 19.993000 C 10:20:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:20:13 Integrated Voltage Measurement... 10:20:32 Voltage Offset Correction: v_off_ini = 0.000000596 V, v_off_fin = 0.000006651 V 10:20:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433379 Vs 10:20:32 Integrated Voltage Measurement... 10:20:52 Voltage Offset Correction: v_off_ini = 0.000006302 V, v_off_fin = -0.000001791 V 10:20:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308784 Vs 10:20:54 Temperature Measurement, Probe Number = 0, T = 20.418000 C 10:20:55 Temperature Measurement, Probe Number = 1, T = 20.049000 C 10:20:56 Temperature Measurement, Probe Number = 2, T = 20.020000 C 10:20:56 Temperature Measurement, Probe Number = 3, T = 19.990000 C 10:20:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:20:57 Integrated Voltage Measurement... 10:21:16 Voltage Offset Correction: v_off_ini = 0.000001906 V, v_off_fin = 0.000006347 V 10:21:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435421 Vs 10:21:16 Integrated Voltage Measurement... 10:21:36 Voltage Offset Correction: v_off_ini = 0.000005382 V, v_off_fin = -0.000001025 V 10:21:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315158 Vs 10:51:38 Temperature Measurement, Probe Number = 0, T = 20.339000 C 10:51:39 Temperature Measurement, Probe Number = 1, T = 20.051000 C 10:51:40 Temperature Measurement, Probe Number = 2, T = 20.027000 C 10:51:40 Temperature Measurement, Probe Number = 3, T = 19.991000 C 10:51:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:51:41 Integrated Voltage Measurement... 10:52:00 Voltage Offset Correction: v_off_ini = 0.000004832 V, v_off_fin = 0.000006963 V 10:52:00 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175537539 Vs 10:52:00 Integrated Voltage Measurement... 10:52:19 Voltage Offset Correction: v_off_ini = 0.000005994 V, v_off_fin = -0.000001547 V 10:52:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310142 Vs 10:52:22 Temperature Measurement, Probe Number = 0, T = 20.360000 C 10:52:23 Temperature Measurement, Probe Number = 1, T = 20.053000 C 10:52:24 Temperature Measurement, Probe Number = 2, T = 20.029000 C 10:52:24 Temperature Measurement, Probe Number = 3, T = 19.996000 C 10:52:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 10:52:24 Integrated Voltage Measurement... 10:52:44 Voltage Offset Correction: v_off_ini = 0.000001887 V, v_off_fin = 0.000006333 V 10:52:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438382 Vs 10:52:44 Integrated Voltage Measurement... 10:53:03 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000001970 V 10:53:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308012 Vs 10:53:06 Temperature Measurement, Probe Number = 0, T = 20.401000 C 10:53:07 Temperature Measurement, Probe Number = 1, T = 20.056000 C 10:53:07 Temperature Measurement, Probe Number = 2, T = 20.028000 C 10:53:08 Temperature Measurement, Probe Number = 3, T = 19.996000 C 10:53:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 10:53:08 Integrated Voltage Measurement... 10:53:28 Voltage Offset Correction: v_off_ini = 0.000002213 V, v_off_fin = 0.000006469 V 10:53:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436621 Vs 10:53:28 Integrated Voltage Measurement... 10:53:47 Voltage Offset Correction: v_off_ini = 0.000005594 V, v_off_fin = -0.000002053 V 10:53:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306941 Vs 10:53:50 Temperature Measurement, Probe Number = 0, T = 20.422000 C 10:53:51 Temperature Measurement, Probe Number = 1, T = 20.053000 C 10:53:51 Temperature Measurement, Probe Number = 2, T = 20.026000 C 10:53:52 Temperature Measurement, Probe Number = 3, T = 19.996000 C 10:53:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 10:53:52 Integrated Voltage Measurement... 10:54:11 Voltage Offset Correction: v_off_ini = 0.000002288 V, v_off_fin = 0.000006606 V 10:54:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439575 Vs 10:54:12 Integrated Voltage Measurement... 10:54:31 Voltage Offset Correction: v_off_ini = 0.000005472 V, v_off_fin = -0.000002248 V 10:54:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304005 Vs 10:54:33 Temperature Measurement, Probe Number = 0, T = 20.432000 C 10:54:34 Temperature Measurement, Probe Number = 1, T = 20.052000 C 10:54:35 Temperature Measurement, Probe Number = 2, T = 20.025000 C 10:54:35 Temperature Measurement, Probe Number = 3, T = 19.995000 C 10:54:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 10:54:36 Integrated Voltage Measurement... 10:54:55 Voltage Offset Correction: v_off_ini = 0.000002097 V, v_off_fin = 0.000006276 V 10:54:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438960 Vs 10:54:55 Integrated Voltage Measurement... 10:55:14 Voltage Offset Correction: v_off_ini = 0.000005751 V, v_off_fin = -0.000002218 V 10:55:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302158 Vs 10:55:17 Temperature Measurement, Probe Number = 0, T = 20.400000 C 10:55:18 Temperature Measurement, Probe Number = 1, T = 20.052000 C 10:55:18 Temperature Measurement, Probe Number = 2, T = 20.023000 C 10:55:19 Temperature Measurement, Probe Number = 3, T = 19.996000 C 10:55:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 10:55:19 Integrated Voltage Measurement... 10:55:38 Voltage Offset Correction: v_off_ini = 0.000001961 V, v_off_fin = 0.000006118 V 10:55:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438269 Vs 10:55:38 Integrated Voltage Measurement... 10:55:58 Voltage Offset Correction: v_off_ini = 0.000005282 V, v_off_fin = -0.000001884 V 10:55:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315548 Vs 10:56:00 Temperature Measurement, Probe Number = 0, T = 20.400000 C 10:56:01 Temperature Measurement, Probe Number = 1, T = 20.052000 C 10:56:02 Temperature Measurement, Probe Number = 2, T = 20.023000 C 10:56:02 Temperature Measurement, Probe Number = 3, T = 19.993000 C 10:56:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 10:56:03 Integrated Voltage Measurement... 10:56:22 Voltage Offset Correction: v_off_ini = 0.000002160 V, v_off_fin = 0.000006251 V 10:56:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430902 Vs 10:56:22 Integrated Voltage Measurement... 10:56:41 Voltage Offset Correction: v_off_ini = 0.000005871 V, v_off_fin = -0.000002381 V 10:56:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304678 Vs 10:56:44 Temperature Measurement, Probe Number = 0, T = 20.396000 C 10:56:45 Temperature Measurement, Probe Number = 1, T = 20.054000 C 10:56:45 Temperature Measurement, Probe Number = 2, T = 20.028000 C 10:56:46 Temperature Measurement, Probe Number = 3, T = 19.995000 C 10:56:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 10:56:46 Integrated Voltage Measurement... 10:57:05 Voltage Offset Correction: v_off_ini = 0.000001099 V, v_off_fin = 0.000007439 V 10:57:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439550 Vs 10:57:05 Integrated Voltage Measurement... 10:57:24 Voltage Offset Correction: v_off_ini = 0.000006502 V, v_off_fin = -0.000000845 V 10:57:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302508 Vs 10:57:27 Temperature Measurement, Probe Number = 0, T = 20.390000 C 10:57:28 Temperature Measurement, Probe Number = 1, T = 20.053000 C 10:57:28 Temperature Measurement, Probe Number = 2, T = 20.027000 C 10:57:29 Temperature Measurement, Probe Number = 3, T = 19.994000 C 10:57:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:57:29 Integrated Voltage Measurement... 10:57:48 Voltage Offset Correction: v_off_ini = 0.000002429 V, v_off_fin = 0.000006972 V 10:57:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441618 Vs 10:57:49 Integrated Voltage Measurement... 10:58:08 Voltage Offset Correction: v_off_ini = 0.000006042 V, v_off_fin = -0.000001509 V 10:58:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301842 Vs 10:58:11 Temperature Measurement, Probe Number = 0, T = 20.304000 C 10:58:11 Temperature Measurement, Probe Number = 1, T = 20.051000 C 10:58:12 Temperature Measurement, Probe Number = 2, T = 20.027000 C 10:58:13 Temperature Measurement, Probe Number = 3, T = 19.994000 C 10:58:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 10:58:13 Integrated Voltage Measurement... 10:58:32 Voltage Offset Correction: v_off_ini = 0.000002044 V, v_off_fin = 0.000006156 V 10:58:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440856 Vs 10:58:32 Integrated Voltage Measurement... 10:58:51 Voltage Offset Correction: v_off_ini = 0.000005802 V, v_off_fin = -0.000001059 V 10:58:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301719 Vs 11:28:54 Temperature Measurement, Probe Number = 0, T = 20.424000 C 11:28:55 Temperature Measurement, Probe Number = 1, T = 20.057000 C 11:28:55 Temperature Measurement, Probe Number = 2, T = 20.032000 C 11:28:56 Temperature Measurement, Probe Number = 3, T = 19.998000 C 11:28:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 11:28:56 Integrated Voltage Measurement... 11:29:15 Voltage Offset Correction: v_off_ini = 0.000004654 V, v_off_fin = 0.000006583 V 11:29:15 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175538033 Vs 11:29:15 Integrated Voltage Measurement... 11:29:35 Voltage Offset Correction: v_off_ini = 0.000005506 V, v_off_fin = -0.000002385 V 11:29:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301388 Vs 11:29:38 Temperature Measurement, Probe Number = 0, T = 20.458000 C 11:29:38 Temperature Measurement, Probe Number = 1, T = 20.058000 C 11:29:39 Temperature Measurement, Probe Number = 2, T = 20.037000 C 11:29:40 Temperature Measurement, Probe Number = 3, T = 19.998000 C 11:29:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:29:40 Integrated Voltage Measurement... 11:29:59 Voltage Offset Correction: v_off_ini = 0.000002026 V, v_off_fin = 0.000006969 V 11:29:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429444 Vs 11:29:59 Integrated Voltage Measurement... 11:30:18 Voltage Offset Correction: v_off_ini = 0.000005913 V, v_off_fin = -0.000001628 V 11:30:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294639 Vs 11:30:21 Temperature Measurement, Probe Number = 0, T = 20.480000 C 11:30:22 Temperature Measurement, Probe Number = 1, T = 20.063000 C 11:30:22 Temperature Measurement, Probe Number = 2, T = 20.040000 C 11:30:23 Temperature Measurement, Probe Number = 3, T = 20.001000 C 11:30:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:30:23 Integrated Voltage Measurement... 11:30:42 Voltage Offset Correction: v_off_ini = 0.000002362 V, v_off_fin = 0.000006104 V 11:30:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435843 Vs 11:30:42 Integrated Voltage Measurement... 11:31:01 Voltage Offset Correction: v_off_ini = 0.000005581 V, v_off_fin = -0.000002133 V 11:31:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298722 Vs 11:31:04 Temperature Measurement, Probe Number = 0, T = 20.450000 C 11:31:05 Temperature Measurement, Probe Number = 1, T = 20.065000 C 11:31:05 Temperature Measurement, Probe Number = 2, T = 20.041000 C 11:31:06 Temperature Measurement, Probe Number = 3, T = 20.004000 C 11:31:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:31:06 Integrated Voltage Measurement... 11:31:25 Voltage Offset Correction: v_off_ini = 0.000000725 V, v_off_fin = 0.000007369 V 11:31:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438559 Vs 11:31:26 Integrated Voltage Measurement... 11:31:45 Voltage Offset Correction: v_off_ini = 0.000006404 V, v_off_fin = -0.000001672 V 11:31:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289486 Vs 11:31:47 Temperature Measurement, Probe Number = 0, T = 20.474000 C 11:31:48 Temperature Measurement, Probe Number = 1, T = 20.065000 C 11:31:49 Temperature Measurement, Probe Number = 2, T = 20.039000 C 11:31:49 Temperature Measurement, Probe Number = 3, T = 20.006000 C 11:31:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 11:31:49 Integrated Voltage Measurement... 11:32:08 Voltage Offset Correction: v_off_ini = 0.000002432 V, v_off_fin = 0.000006761 V 11:32:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443009 Vs 11:32:09 Integrated Voltage Measurement... 11:32:28 Voltage Offset Correction: v_off_ini = 0.000006076 V, v_off_fin = -0.000001069 V 11:32:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307629 Vs 11:32:31 Temperature Measurement, Probe Number = 0, T = 20.488000 C 11:32:32 Temperature Measurement, Probe Number = 1, T = 20.062000 C 11:32:32 Temperature Measurement, Probe Number = 2, T = 20.038000 C 11:32:33 Temperature Measurement, Probe Number = 3, T = 20.003000 C 11:32:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:32:33 Integrated Voltage Measurement... 11:32:52 Voltage Offset Correction: v_off_ini = 0.000001793 V, v_off_fin = 0.000006670 V 11:32:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429293 Vs 11:32:52 Integrated Voltage Measurement... 11:33:11 Voltage Offset Correction: v_off_ini = 0.000005811 V, v_off_fin = -0.000001621 V 11:33:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297067 Vs 11:33:14 Temperature Measurement, Probe Number = 0, T = 20.454000 C 11:33:15 Temperature Measurement, Probe Number = 1, T = 20.062000 C 11:33:16 Temperature Measurement, Probe Number = 2, T = 20.039000 C 11:33:16 Temperature Measurement, Probe Number = 3, T = 20.004000 C 11:33:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:33:16 Integrated Voltage Measurement... 11:33:36 Voltage Offset Correction: v_off_ini = 0.000001614 V, v_off_fin = 0.000006035 V 11:33:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431879 Vs 11:33:36 Integrated Voltage Measurement... 11:33:55 Voltage Offset Correction: v_off_ini = 0.000005382 V, v_off_fin = -0.000001654 V 11:33:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303181 Vs 11:33:58 Temperature Measurement, Probe Number = 0, T = 20.475000 C 11:33:58 Temperature Measurement, Probe Number = 1, T = 20.063000 C 11:33:59 Temperature Measurement, Probe Number = 2, T = 20.037000 C 11:34:00 Temperature Measurement, Probe Number = 3, T = 20.004000 C 11:34:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:34:00 Integrated Voltage Measurement... 11:34:19 Voltage Offset Correction: v_off_ini = 0.000000293 V, v_off_fin = 0.000006672 V 11:34:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438541 Vs 11:34:19 Integrated Voltage Measurement... 11:34:38 Voltage Offset Correction: v_off_ini = 0.000006099 V, v_off_fin = -0.000001467 V 11:34:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296815 Vs 11:34:41 Temperature Measurement, Probe Number = 0, T = 20.472000 C 11:34:42 Temperature Measurement, Probe Number = 1, T = 20.063000 C 11:34:42 Temperature Measurement, Probe Number = 2, T = 20.039000 C 11:34:43 Temperature Measurement, Probe Number = 3, T = 20.004000 C 11:34:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:34:43 Integrated Voltage Measurement... 11:35:03 Voltage Offset Correction: v_off_ini = 0.000002109 V, v_off_fin = 0.000007221 V 11:35:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429523 Vs 11:35:03 Integrated Voltage Measurement... 11:35:22 Voltage Offset Correction: v_off_ini = 0.000006117 V, v_off_fin = -0.000001028 V 11:35:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301499 Vs 11:35:25 Temperature Measurement, Probe Number = 0, T = 20.476000 C 11:35:26 Temperature Measurement, Probe Number = 1, T = 20.063000 C 11:35:27 Temperature Measurement, Probe Number = 2, T = 20.041000 C 11:35:27 Temperature Measurement, Probe Number = 3, T = 20.005000 C 11:35:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 11:35:27 Integrated Voltage Measurement... 11:35:47 Voltage Offset Correction: v_off_ini = 0.000002078 V, v_off_fin = 0.000007188 V 11:35:47 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438611 Vs 11:35:47 Integrated Voltage Measurement... 11:36:07 Voltage Offset Correction: v_off_ini = 0.000006560 V, v_off_fin = -0.000000133 V 11:36:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289740 Vs 12:06:09 Temperature Measurement, Probe Number = 0, T = 20.374000 C 12:06:10 Temperature Measurement, Probe Number = 1, T = 20.063000 C 12:06:11 Temperature Measurement, Probe Number = 2, T = 20.040000 C 12:06:11 Temperature Measurement, Probe Number = 3, T = 20.006000 C 12:06:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 12:06:12 Integrated Voltage Measurement... 12:06:31 Voltage Offset Correction: v_off_ini = 0.000004267 V, v_off_fin = 0.000006427 V 12:06:31 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175523364 Vs 12:06:31 Integrated Voltage Measurement... 12:06:50 Voltage Offset Correction: v_off_ini = 0.000005742 V, v_off_fin = -0.000001515 V 12:06:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289249 Vs 12:06:53 Temperature Measurement, Probe Number = 0, T = 20.398000 C 12:06:53 Temperature Measurement, Probe Number = 1, T = 20.067000 C 12:06:54 Temperature Measurement, Probe Number = 2, T = 20.045000 C 12:06:54 Temperature Measurement, Probe Number = 3, T = 20.007000 C 12:06:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:06:55 Integrated Voltage Measurement... 12:07:15 Voltage Offset Correction: v_off_ini = 0.000002220 V, v_off_fin = 0.000006608 V 12:07:15 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433715 Vs 12:07:16 Integrated Voltage Measurement... 12:07:35 Voltage Offset Correction: v_off_ini = 0.000005863 V, v_off_fin = -0.000001412 V 12:07:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175288067 Vs 12:07:37 Temperature Measurement, Probe Number = 0, T = 20.391000 C 12:07:38 Temperature Measurement, Probe Number = 1, T = 20.068000 C 12:07:39 Temperature Measurement, Probe Number = 2, T = 20.047000 C 12:07:39 Temperature Measurement, Probe Number = 3, T = 20.008000 C 12:07:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:07:40 Integrated Voltage Measurement... 12:07:59 Voltage Offset Correction: v_off_ini = 0.000002354 V, v_off_fin = 0.000006628 V 12:07:59 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430440 Vs 12:07:59 Integrated Voltage Measurement... 12:08:18 Voltage Offset Correction: v_off_ini = 0.000006000 V, v_off_fin = -0.000002183 V 12:08:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300134 Vs 12:08:21 Temperature Measurement, Probe Number = 0, T = 20.374000 C 12:08:22 Temperature Measurement, Probe Number = 1, T = 20.069000 C 12:08:22 Temperature Measurement, Probe Number = 2, T = 20.046000 C 12:08:23 Temperature Measurement, Probe Number = 3, T = 20.007000 C 12:08:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:08:23 Integrated Voltage Measurement... 12:08:42 Voltage Offset Correction: v_off_ini = 0.000001679 V, v_off_fin = 0.000006085 V 12:08:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426440 Vs 12:08:43 Integrated Voltage Measurement... 12:09:02 Voltage Offset Correction: v_off_ini = 0.000005146 V, v_off_fin = -0.000001925 V 12:09:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297263 Vs 12:09:04 Temperature Measurement, Probe Number = 0, T = 20.361000 C 12:09:05 Temperature Measurement, Probe Number = 1, T = 20.066000 C 12:09:06 Temperature Measurement, Probe Number = 2, T = 20.041000 C 12:09:06 Temperature Measurement, Probe Number = 3, T = 20.005000 C 12:09:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 12:09:07 Integrated Voltage Measurement... 12:09:26 Voltage Offset Correction: v_off_ini = 0.000001821 V, v_off_fin = 0.000006336 V 12:09:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420588 Vs 12:09:26 Integrated Voltage Measurement... 12:09:45 Voltage Offset Correction: v_off_ini = 0.000005492 V, v_off_fin = -0.000001419 V 12:09:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298495 Vs 12:09:48 Temperature Measurement, Probe Number = 0, T = 20.402000 C 12:09:49 Temperature Measurement, Probe Number = 1, T = 20.066000 C 12:09:50 Temperature Measurement, Probe Number = 2, T = 20.043000 C 12:09:50 Temperature Measurement, Probe Number = 3, T = 20.006000 C 12:09:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 12:09:51 Integrated Voltage Measurement... 12:10:10 Voltage Offset Correction: v_off_ini = 0.000001867 V, v_off_fin = 0.000006088 V 12:10:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437177 Vs 12:10:10 Integrated Voltage Measurement... 12:10:30 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000002382 V 12:10:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301212 Vs 12:10:32 Temperature Measurement, Probe Number = 0, T = 20.442000 C 12:10:33 Temperature Measurement, Probe Number = 1, T = 20.069000 C 12:10:34 Temperature Measurement, Probe Number = 2, T = 20.045000 C 12:10:34 Temperature Measurement, Probe Number = 3, T = 20.011000 C 12:10:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:10:35 Integrated Voltage Measurement... 12:10:54 Voltage Offset Correction: v_off_ini = 0.000001734 V, v_off_fin = 0.000005692 V 12:10:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423259 Vs 12:10:54 Integrated Voltage Measurement... 12:11:13 Voltage Offset Correction: v_off_ini = 0.000005388 V, v_off_fin = -0.000002978 V 12:11:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304149 Vs 12:11:16 Temperature Measurement, Probe Number = 0, T = 20.481000 C 12:11:16 Temperature Measurement, Probe Number = 1, T = 20.070000 C 12:11:17 Temperature Measurement, Probe Number = 2, T = 20.047000 C 12:11:18 Temperature Measurement, Probe Number = 3, T = 20.012000 C 12:11:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:11:18 Integrated Voltage Measurement... 12:11:37 Voltage Offset Correction: v_off_ini = 0.000001271 V, v_off_fin = 0.000006144 V 12:11:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426674 Vs 12:11:37 Integrated Voltage Measurement... 12:11:56 Voltage Offset Correction: v_off_ini = 0.000004815 V, v_off_fin = -0.000001818 V 12:11:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302349 Vs 12:11:59 Temperature Measurement, Probe Number = 0, T = 20.521000 C 12:12:00 Temperature Measurement, Probe Number = 1, T = 20.070000 C 12:12:00 Temperature Measurement, Probe Number = 2, T = 20.047000 C 12:12:01 Temperature Measurement, Probe Number = 3, T = 20.012000 C 12:12:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:12:01 Integrated Voltage Measurement... 12:12:20 Voltage Offset Correction: v_off_ini = 0.000000985 V, v_off_fin = 0.000006233 V 12:12:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424718 Vs 12:12:20 Integrated Voltage Measurement... 12:12:40 Voltage Offset Correction: v_off_ini = 0.000005578 V, v_off_fin = -0.000001051 V 12:12:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306310 Vs 12:12:42 Temperature Measurement, Probe Number = 0, T = 20.501000 C 12:12:43 Temperature Measurement, Probe Number = 1, T = 20.070000 C 12:12:44 Temperature Measurement, Probe Number = 2, T = 20.045000 C 12:12:44 Temperature Measurement, Probe Number = 3, T = 20.011000 C 12:12:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:12:45 Integrated Voltage Measurement... 12:13:04 Voltage Offset Correction: v_off_ini = 0.000001756 V, v_off_fin = 0.000006546 V 12:13:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431393 Vs 12:13:04 Integrated Voltage Measurement... 12:13:23 Voltage Offset Correction: v_off_ini = 0.000005567 V, v_off_fin = -0.000002283 V 12:13:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296788 Vs 12:43:26 Temperature Measurement, Probe Number = 0, T = 20.390000 C 12:43:27 Temperature Measurement, Probe Number = 1, T = 20.073000 C 12:43:27 Temperature Measurement, Probe Number = 2, T = 20.046000 C 12:43:28 Temperature Measurement, Probe Number = 3, T = 20.016000 C 12:43:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:43:28 Integrated Voltage Measurement... 12:43:47 Voltage Offset Correction: v_off_ini = 0.000003682 V, v_off_fin = 0.000006295 V 12:43:47 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175525234 Vs 12:43:47 Integrated Voltage Measurement... 12:44:06 Voltage Offset Correction: v_off_ini = 0.000005334 V, v_off_fin = -0.000001766 V 12:44:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300475 Vs 12:44:09 Temperature Measurement, Probe Number = 0, T = 20.344000 C 12:44:10 Temperature Measurement, Probe Number = 1, T = 20.073000 C 12:44:10 Temperature Measurement, Probe Number = 2, T = 20.047000 C 12:44:11 Temperature Measurement, Probe Number = 3, T = 20.014000 C 12:44:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 12:44:11 Integrated Voltage Measurement... 12:44:30 Voltage Offset Correction: v_off_ini = 0.000001514 V, v_off_fin = 0.000005556 V 12:44:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427745 Vs 12:44:31 Integrated Voltage Measurement... 12:44:50 Voltage Offset Correction: v_off_ini = 0.000004715 V, v_off_fin = -0.000002075 V 12:44:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302194 Vs 12:44:53 Temperature Measurement, Probe Number = 0, T = 20.357000 C 12:44:53 Temperature Measurement, Probe Number = 1, T = 20.073000 C 12:44:54 Temperature Measurement, Probe Number = 2, T = 20.051000 C 12:44:54 Temperature Measurement, Probe Number = 3, T = 20.016000 C 12:44:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:44:55 Integrated Voltage Measurement... 12:45:14 Voltage Offset Correction: v_off_ini = 0.000001263 V, v_off_fin = 0.000006499 V 12:45:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426299 Vs 12:45:14 Integrated Voltage Measurement... 12:45:33 Voltage Offset Correction: v_off_ini = 0.000005315 V, v_off_fin = -0.000002029 V 12:45:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295007 Vs 12:45:36 Temperature Measurement, Probe Number = 0, T = 20.351000 C 12:45:37 Temperature Measurement, Probe Number = 1, T = 20.074000 C 12:45:37 Temperature Measurement, Probe Number = 2, T = 20.051000 C 12:45:38 Temperature Measurement, Probe Number = 3, T = 20.019000 C 12:45:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:45:38 Integrated Voltage Measurement... 12:45:57 Voltage Offset Correction: v_off_ini = 0.000001408 V, v_off_fin = 0.000005842 V 12:45:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423914 Vs 12:45:58 Integrated Voltage Measurement... 12:46:17 Voltage Offset Correction: v_off_ini = 0.000005751 V, v_off_fin = -0.000002121 V 12:46:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307764 Vs 12:46:19 Temperature Measurement, Probe Number = 0, T = 20.353000 C 12:46:20 Temperature Measurement, Probe Number = 1, T = 20.075000 C 12:46:21 Temperature Measurement, Probe Number = 2, T = 20.051000 C 12:46:21 Temperature Measurement, Probe Number = 3, T = 20.017000 C 12:46:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:46:22 Integrated Voltage Measurement... 12:46:41 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000005964 V 12:46:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425391 Vs 12:46:41 Integrated Voltage Measurement... 12:47:00 Voltage Offset Correction: v_off_ini = 0.000004766 V, v_off_fin = -0.000002167 V 12:47:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300893 Vs 12:47:03 Temperature Measurement, Probe Number = 0, T = 20.351000 C 12:47:04 Temperature Measurement, Probe Number = 1, T = 20.074000 C 12:47:04 Temperature Measurement, Probe Number = 2, T = 20.051000 C 12:47:05 Temperature Measurement, Probe Number = 3, T = 20.016000 C 12:47:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:47:05 Integrated Voltage Measurement... 12:47:24 Voltage Offset Correction: v_off_ini = 0.000001574 V, v_off_fin = 0.000006512 V 12:47:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426512 Vs 12:47:25 Integrated Voltage Measurement... 12:47:44 Voltage Offset Correction: v_off_ini = 0.000005691 V, v_off_fin = -0.000001518 V 12:47:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306241 Vs 12:47:47 Temperature Measurement, Probe Number = 0, T = 20.342000 C 12:47:48 Temperature Measurement, Probe Number = 1, T = 20.074000 C 12:47:48 Temperature Measurement, Probe Number = 2, T = 20.052000 C 12:47:49 Temperature Measurement, Probe Number = 3, T = 20.018000 C 12:47:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:47:49 Integrated Voltage Measurement... 12:48:08 Voltage Offset Correction: v_off_ini = 0.000002143 V, v_off_fin = 0.000006643 V 12:48:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430206 Vs 12:48:09 Integrated Voltage Measurement... 12:48:27 Voltage Offset Correction: v_off_ini = 0.000005999 V, v_off_fin = -0.000001822 V 12:48:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296664 Vs 12:48:30 Temperature Measurement, Probe Number = 0, T = 20.337000 C 12:48:31 Temperature Measurement, Probe Number = 1, T = 20.076000 C 12:48:32 Temperature Measurement, Probe Number = 2, T = 20.053000 C 12:48:32 Temperature Measurement, Probe Number = 3, T = 20.020000 C 12:48:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:48:32 Integrated Voltage Measurement... 12:48:51 Voltage Offset Correction: v_off_ini = 0.000001293 V, v_off_fin = 0.000006182 V 12:48:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426348 Vs 12:48:52 Integrated Voltage Measurement... 12:49:11 Voltage Offset Correction: v_off_ini = 0.000005716 V, v_off_fin = -0.000001248 V 12:49:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300109 Vs 12:49:13 Temperature Measurement, Probe Number = 0, T = 20.346000 C 12:49:14 Temperature Measurement, Probe Number = 1, T = 20.076000 C 12:49:15 Temperature Measurement, Probe Number = 2, T = 20.055000 C 12:49:15 Temperature Measurement, Probe Number = 3, T = 20.021000 C 12:49:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:49:16 Integrated Voltage Measurement... 12:49:34 Voltage Offset Correction: v_off_ini = 0.000000974 V, v_off_fin = 0.000006159 V 12:49:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429555 Vs 12:49:35 Integrated Voltage Measurement... 12:49:54 Voltage Offset Correction: v_off_ini = 0.000005479 V, v_off_fin = -0.000002566 V 12:49:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303568 Vs 12:49:57 Temperature Measurement, Probe Number = 0, T = 20.372000 C 12:49:57 Temperature Measurement, Probe Number = 1, T = 20.076000 C 12:49:58 Temperature Measurement, Probe Number = 2, T = 20.050000 C 12:49:59 Temperature Measurement, Probe Number = 3, T = 20.018000 C 12:49:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 12:49:59 Integrated Voltage Measurement... 12:50:18 Voltage Offset Correction: v_off_ini = 0.000001207 V, v_off_fin = 0.000005670 V 12:50:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428012 Vs 12:50:18 Integrated Voltage Measurement... 12:50:38 Voltage Offset Correction: v_off_ini = 0.000005004 V, v_off_fin = -0.000001535 V 12:50:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307896 Vs 13:20:41 Temperature Measurement, Probe Number = 0, T = 20.446000 C 13:20:41 Temperature Measurement, Probe Number = 1, T = 20.082000 C 13:20:42 Temperature Measurement, Probe Number = 2, T = 20.059000 C 13:20:43 Temperature Measurement, Probe Number = 3, T = 20.025000 C 13:20:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 13:20:43 Integrated Voltage Measurement... 13:21:02 Voltage Offset Correction: v_off_ini = 0.000004111 V, v_off_fin = 0.000006505 V 13:21:02 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175529076 Vs 13:21:02 Integrated Voltage Measurement... 13:21:22 Voltage Offset Correction: v_off_ini = 0.000005703 V, v_off_fin = -0.000002321 V 13:21:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290947 Vs 13:21:24 Temperature Measurement, Probe Number = 0, T = 20.383000 C 13:21:25 Temperature Measurement, Probe Number = 1, T = 20.084000 C 13:21:26 Temperature Measurement, Probe Number = 2, T = 20.062000 C 13:21:26 Temperature Measurement, Probe Number = 3, T = 20.028000 C 13:21:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 13:21:26 Integrated Voltage Measurement... 13:21:46 Voltage Offset Correction: v_off_ini = 0.000001871 V, v_off_fin = 0.000006613 V 13:21:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429860 Vs 13:21:46 Integrated Voltage Measurement... 13:22:05 Voltage Offset Correction: v_off_ini = 0.000005620 V, v_off_fin = -0.000001085 V 13:22:06 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293213 Vs 13:22:08 Temperature Measurement, Probe Number = 0, T = 20.416000 C 13:22:09 Temperature Measurement, Probe Number = 1, T = 20.085000 C 13:22:10 Temperature Measurement, Probe Number = 2, T = 20.061000 C 13:22:10 Temperature Measurement, Probe Number = 3, T = 20.028000 C 13:22:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 13:22:10 Integrated Voltage Measurement... 13:22:30 Voltage Offset Correction: v_off_ini = 0.000001733 V, v_off_fin = 0.000005536 V 13:22:30 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175420551 Vs 13:22:30 Integrated Voltage Measurement... 13:22:50 Voltage Offset Correction: v_off_ini = 0.000004727 V, v_off_fin = -0.000003202 V 13:22:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306094 Vs 13:22:52 Temperature Measurement, Probe Number = 0, T = 20.437000 C 13:22:53 Temperature Measurement, Probe Number = 1, T = 20.085000 C 13:22:54 Temperature Measurement, Probe Number = 2, T = 20.063000 C 13:22:54 Temperature Measurement, Probe Number = 3, T = 20.028000 C 13:22:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 13:22:55 Integrated Voltage Measurement... 13:23:14 Voltage Offset Correction: v_off_ini = 0.000000914 V, v_off_fin = 0.000006281 V 13:23:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421164 Vs 13:23:14 Integrated Voltage Measurement... 13:23:33 Voltage Offset Correction: v_off_ini = 0.000005347 V, v_off_fin = -0.000002354 V 13:23:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292646 Vs 13:23:35 Temperature Measurement, Probe Number = 0, T = 20.456000 C 13:23:36 Temperature Measurement, Probe Number = 1, T = 20.085000 C 13:23:37 Temperature Measurement, Probe Number = 2, T = 20.062000 C 13:23:37 Temperature Measurement, Probe Number = 3, T = 20.025000 C 13:23:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 13:23:38 Integrated Voltage Measurement... 13:23:57 Voltage Offset Correction: v_off_ini = 0.000001463 V, v_off_fin = 0.000006655 V 13:23:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432388 Vs 13:23:57 Integrated Voltage Measurement... 13:24:16 Voltage Offset Correction: v_off_ini = 0.000006245 V, v_off_fin = -0.000002247 V 13:24:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296241 Vs 13:24:19 Temperature Measurement, Probe Number = 0, T = 20.485000 C 13:24:20 Temperature Measurement, Probe Number = 1, T = 20.088000 C 13:24:20 Temperature Measurement, Probe Number = 2, T = 20.066000 C 13:24:21 Temperature Measurement, Probe Number = 3, T = 20.028000 C 13:24:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 13:24:21 Integrated Voltage Measurement... 13:24:41 Voltage Offset Correction: v_off_ini = 0.000001793 V, v_off_fin = 0.000006929 V 13:24:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430086 Vs 13:24:41 Integrated Voltage Measurement... 13:25:00 Voltage Offset Correction: v_off_ini = 0.000005899 V, v_off_fin = -0.000001808 V 13:25:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288960 Vs 13:25:03 Temperature Measurement, Probe Number = 0, T = 20.492000 C 13:25:03 Temperature Measurement, Probe Number = 1, T = 20.088000 C 13:25:04 Temperature Measurement, Probe Number = 2, T = 20.066000 C 13:25:05 Temperature Measurement, Probe Number = 3, T = 20.029000 C 13:25:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 13:25:05 Integrated Voltage Measurement... 13:25:24 Voltage Offset Correction: v_off_ini = 0.000000551 V, v_off_fin = 0.000007048 V 13:25:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437457 Vs 13:25:24 Integrated Voltage Measurement... 13:25:44 Voltage Offset Correction: v_off_ini = 0.000006474 V, v_off_fin = -0.000000902 V 13:25:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175286527 Vs 13:25:47 Temperature Measurement, Probe Number = 0, T = 20.445000 C 13:25:47 Temperature Measurement, Probe Number = 1, T = 20.090000 C 13:25:48 Temperature Measurement, Probe Number = 2, T = 20.067000 C 13:25:49 Temperature Measurement, Probe Number = 3, T = 20.030000 C 13:25:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 13:25:49 Integrated Voltage Measurement... 13:26:08 Voltage Offset Correction: v_off_ini = 0.000002172 V, v_off_fin = 0.000006205 V 13:26:08 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175418329 Vs 13:26:08 Integrated Voltage Measurement... 13:26:27 Voltage Offset Correction: v_off_ini = 0.000005669 V, v_off_fin = -0.000001775 V 13:26:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294311 Vs 13:26:30 Temperature Measurement, Probe Number = 0, T = 20.456000 C 13:26:30 Temperature Measurement, Probe Number = 1, T = 20.089000 C 13:26:31 Temperature Measurement, Probe Number = 2, T = 20.068000 C 13:26:32 Temperature Measurement, Probe Number = 3, T = 20.029000 C 13:26:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 13:26:32 Integrated Voltage Measurement... 13:26:51 Voltage Offset Correction: v_off_ini = 0.000001199 V, v_off_fin = 0.000006208 V 13:26:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425710 Vs 13:26:51 Integrated Voltage Measurement... 13:27:10 Voltage Offset Correction: v_off_ini = 0.000005522 V, v_off_fin = -0.000001342 V 13:27:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293283 Vs 13:27:13 Temperature Measurement, Probe Number = 0, T = 20.520000 C 13:27:14 Temperature Measurement, Probe Number = 1, T = 20.089000 C 13:27:14 Temperature Measurement, Probe Number = 2, T = 20.068000 C 13:27:15 Temperature Measurement, Probe Number = 3, T = 20.030000 C 13:27:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 13:27:15 Integrated Voltage Measurement... 13:27:34 Voltage Offset Correction: v_off_ini = 0.000001984 V, v_off_fin = 0.000006358 V 13:27:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432230 Vs 13:27:34 Integrated Voltage Measurement... 13:27:53 Voltage Offset Correction: v_off_ini = 0.000005625 V, v_off_fin = -0.000002603 V 13:27:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300802 Vs 13:57:56 Temperature Measurement, Probe Number = 0, T = 20.178000 C 13:57:57 Temperature Measurement, Probe Number = 1, T = 20.078000 C 13:57:58 Temperature Measurement, Probe Number = 2, T = 20.052000 C 13:57:58 Temperature Measurement, Probe Number = 3, T = 20.023000 C 13:57:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 13:57:58 Integrated Voltage Measurement... 13:58:18 Voltage Offset Correction: v_off_ini = 0.000004447 V, v_off_fin = 0.000006387 V 13:58:18 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175521945 Vs 13:58:18 Integrated Voltage Measurement... 13:58:37 Voltage Offset Correction: v_off_ini = 0.000005369 V, v_off_fin = -0.000000917 V 13:58:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305095 Vs 13:58:40 Temperature Measurement, Probe Number = 0, T = 20.061000 C 13:58:41 Temperature Measurement, Probe Number = 1, T = 20.081000 C 13:58:41 Temperature Measurement, Probe Number = 2, T = 20.055000 C 13:58:42 Temperature Measurement, Probe Number = 3, T = 20.023000 C 13:58:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 13:58:42 Integrated Voltage Measurement... 13:59:01 Voltage Offset Correction: v_off_ini = 0.000002580 V, v_off_fin = 0.000006898 V 13:59:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447518 Vs 13:59:01 Integrated Voltage Measurement... 13:59:20 Voltage Offset Correction: v_off_ini = 0.000006158 V, v_off_fin = -0.000001394 V 13:59:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301112 Vs 13:59:23 Temperature Measurement, Probe Number = 0, T = 20.019000 C 13:59:24 Temperature Measurement, Probe Number = 1, T = 20.078000 C 13:59:24 Temperature Measurement, Probe Number = 2, T = 20.047000 C 13:59:25 Temperature Measurement, Probe Number = 3, T = 20.019000 C 13:59:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.02 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 13:59:25 Integrated Voltage Measurement... 13:59:44 Voltage Offset Correction: v_off_ini = 0.000002056 V, v_off_fin = 0.000006778 V 13:59:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445157 Vs 13:59:45 Integrated Voltage Measurement... 14:00:04 Voltage Offset Correction: v_off_ini = 0.000005623 V, v_off_fin = -0.000001493 V 14:00:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303012 Vs 14:00:07 Temperature Measurement, Probe Number = 0, T = 19.977000 C 14:00:08 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:00:08 Temperature Measurement, Probe Number = 2, T = 20.052000 C 14:00:09 Temperature Measurement, Probe Number = 3, T = 20.021000 C 14:00:09 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:00:09 Integrated Voltage Measurement... 14:00:28 Voltage Offset Correction: v_off_ini = 0.000001962 V, v_off_fin = 0.000006733 V 14:00:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435312 Vs 14:00:28 Integrated Voltage Measurement... 14:00:48 Voltage Offset Correction: v_off_ini = 0.000005792 V, v_off_fin = -0.000001515 V 14:00:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309467 Vs 14:00:51 Temperature Measurement, Probe Number = 0, T = 20.048000 C 14:00:51 Temperature Measurement, Probe Number = 1, T = 20.080000 C 14:00:52 Temperature Measurement, Probe Number = 2, T = 20.056000 C 14:00:53 Temperature Measurement, Probe Number = 3, T = 20.022000 C 14:00:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:00:53 Integrated Voltage Measurement... 14:01:12 Voltage Offset Correction: v_off_ini = 0.000001881 V, v_off_fin = 0.000006788 V 14:01:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437389 Vs 14:01:12 Integrated Voltage Measurement... 14:01:31 Voltage Offset Correction: v_off_ini = 0.000006200 V, v_off_fin = -0.000001606 V 14:01:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301265 Vs 14:01:34 Temperature Measurement, Probe Number = 0, T = 20.063000 C 14:01:35 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:01:35 Temperature Measurement, Probe Number = 2, T = 20.049000 C 14:01:36 Temperature Measurement, Probe Number = 3, T = 20.019000 C 14:01:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:01:36 Integrated Voltage Measurement... 14:01:55 Voltage Offset Correction: v_off_ini = 0.000001359 V, v_off_fin = 0.000006295 V 14:01:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435912 Vs 14:01:55 Integrated Voltage Measurement... 14:02:15 Voltage Offset Correction: v_off_ini = 0.000005670 V, v_off_fin = -0.000000890 V 14:02:15 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304871 Vs 14:02:18 Temperature Measurement, Probe Number = 0, T = 20.080000 C 14:02:19 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:02:19 Temperature Measurement, Probe Number = 2, T = 20.049000 C 14:02:20 Temperature Measurement, Probe Number = 3, T = 20.017000 C 14:02:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:02:20 Integrated Voltage Measurement... 14:02:39 Voltage Offset Correction: v_off_ini = 0.000001475 V, v_off_fin = 0.000006702 V 14:02:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175434247 Vs 14:02:40 Integrated Voltage Measurement... 14:02:58 Voltage Offset Correction: v_off_ini = 0.000005921 V, v_off_fin = -0.000002504 V 14:02:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301013 Vs 14:03:01 Temperature Measurement, Probe Number = 0, T = 20.082000 C 14:03:02 Temperature Measurement, Probe Number = 1, T = 20.074000 C 14:03:03 Temperature Measurement, Probe Number = 2, T = 20.044000 C 14:03:03 Temperature Measurement, Probe Number = 3, T = 20.017000 C 14:03:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 14:03:03 Integrated Voltage Measurement... 14:03:22 Voltage Offset Correction: v_off_ini = 0.000002358 V, v_off_fin = 0.000006623 V 14:03:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438971 Vs 14:03:23 Integrated Voltage Measurement... 14:03:42 Voltage Offset Correction: v_off_ini = 0.000005512 V, v_off_fin = -0.000001979 V 14:03:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306724 Vs 14:03:44 Temperature Measurement, Probe Number = 0, T = 20.096000 C 14:03:45 Temperature Measurement, Probe Number = 1, T = 20.076000 C 14:03:46 Temperature Measurement, Probe Number = 2, T = 20.050000 C 14:03:46 Temperature Measurement, Probe Number = 3, T = 20.020000 C 14:03:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:03:47 Integrated Voltage Measurement... 14:04:06 Voltage Offset Correction: v_off_ini = 0.000002170 V, v_off_fin = 0.000006760 V 14:04:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437983 Vs 14:04:06 Integrated Voltage Measurement... 14:04:25 Voltage Offset Correction: v_off_ini = 0.000005247 V, v_off_fin = -0.000001736 V 14:04:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307255 Vs 14:04:28 Temperature Measurement, Probe Number = 0, T = 20.150000 C 14:04:29 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:04:29 Temperature Measurement, Probe Number = 2, T = 20.050000 C 14:04:30 Temperature Measurement, Probe Number = 3, T = 20.022000 C 14:04:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:04:30 Integrated Voltage Measurement... 14:04:49 Voltage Offset Correction: v_off_ini = 0.000001891 V, v_off_fin = 0.000005848 V 14:04:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436533 Vs 14:04:49 Integrated Voltage Measurement... 14:05:09 Voltage Offset Correction: v_off_ini = 0.000005073 V, v_off_fin = -0.000002204 V 14:05:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304877 Vs 14:35:11 Temperature Measurement, Probe Number = 0, T = 20.211000 C 14:35:12 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:35:13 Temperature Measurement, Probe Number = 2, T = 20.053000 C 14:35:14 Temperature Measurement, Probe Number = 3, T = 20.020000 C 14:35:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:35:14 Integrated Voltage Measurement... 14:35:33 Voltage Offset Correction: v_off_ini = 0.000004445 V, v_off_fin = 0.000006568 V 14:35:33 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175528444 Vs 14:35:33 Integrated Voltage Measurement... 14:35:53 Voltage Offset Correction: v_off_ini = 0.000005754 V, v_off_fin = -0.000001837 V 14:35:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296819 Vs 14:35:55 Temperature Measurement, Probe Number = 0, T = 20.216000 C 14:35:56 Temperature Measurement, Probe Number = 1, T = 20.082000 C 14:35:57 Temperature Measurement, Probe Number = 2, T = 20.056000 C 14:35:57 Temperature Measurement, Probe Number = 3, T = 20.024000 C 14:35:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:35:58 Integrated Voltage Measurement... 14:36:17 Voltage Offset Correction: v_off_ini = 0.000002192 V, v_off_fin = 0.000006510 V 14:36:17 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434557 Vs 14:36:17 Integrated Voltage Measurement... 14:36:36 Voltage Offset Correction: v_off_ini = 0.000005742 V, v_off_fin = -0.000001509 V 14:36:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300368 Vs 14:36:39 Temperature Measurement, Probe Number = 0, T = 20.279000 C 14:36:40 Temperature Measurement, Probe Number = 1, T = 20.079000 C 14:36:40 Temperature Measurement, Probe Number = 2, T = 20.052000 C 14:36:41 Temperature Measurement, Probe Number = 3, T = 20.019000 C 14:36:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:36:41 Integrated Voltage Measurement... 14:37:00 Voltage Offset Correction: v_off_ini = 0.000001517 V, v_off_fin = 0.000006871 V 14:37:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433853 Vs 14:37:00 Integrated Voltage Measurement... 14:37:20 Voltage Offset Correction: v_off_ini = 0.000005500 V, v_off_fin = -0.000001415 V 14:37:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303288 Vs 14:37:22 Temperature Measurement, Probe Number = 0, T = 20.215000 C 14:37:23 Temperature Measurement, Probe Number = 1, T = 20.079000 C 14:37:24 Temperature Measurement, Probe Number = 2, T = 20.051000 C 14:37:24 Temperature Measurement, Probe Number = 3, T = 20.018000 C 14:37:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:37:25 Integrated Voltage Measurement... 14:37:44 Voltage Offset Correction: v_off_ini = 0.000001537 V, v_off_fin = 0.000006190 V 14:37:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431040 Vs 14:37:44 Integrated Voltage Measurement... 14:38:03 Voltage Offset Correction: v_off_ini = 0.000005882 V, v_off_fin = -0.000001419 V 14:38:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302170 Vs 14:38:06 Temperature Measurement, Probe Number = 0, T = 20.226000 C 14:38:07 Temperature Measurement, Probe Number = 1, T = 20.081000 C 14:38:07 Temperature Measurement, Probe Number = 2, T = 20.051000 C 14:38:08 Temperature Measurement, Probe Number = 3, T = 20.024000 C 14:38:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:38:08 Integrated Voltage Measurement... 14:38:28 Voltage Offset Correction: v_off_ini = 0.000001806 V, v_off_fin = 0.000006644 V 14:38:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435350 Vs 14:38:28 Integrated Voltage Measurement... 14:38:47 Voltage Offset Correction: v_off_ini = 0.000005633 V, v_off_fin = -0.000001231 V 14:38:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301394 Vs 14:38:50 Temperature Measurement, Probe Number = 0, T = 20.252000 C 14:38:51 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:38:51 Temperature Measurement, Probe Number = 2, T = 20.057000 C 14:38:52 Temperature Measurement, Probe Number = 3, T = 20.025000 C 14:38:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:38:52 Integrated Voltage Measurement... 14:39:11 Voltage Offset Correction: v_off_ini = 0.000002511 V, v_off_fin = 0.000007419 V 14:39:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175443216 Vs 14:39:12 Integrated Voltage Measurement... 14:39:35 Voltage Offset Correction: v_off_ini = 0.000006251 V, v_off_fin = 0.000004149 V 14:39:35 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175293830 Vs 14:39:38 Temperature Measurement, Probe Number = 0, T = 20.312000 C 14:39:38 Temperature Measurement, Probe Number = 1, T = 20.085000 C 14:39:39 Temperature Measurement, Probe Number = 2, T = 20.059000 C 14:39:40 Temperature Measurement, Probe Number = 3, T = 20.026000 C 14:39:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 14:39:40 Integrated Voltage Measurement... 14:39:59 Voltage Offset Correction: v_off_ini = 0.000003249 V, v_off_fin = 0.000006326 V 14:39:59 Integrated Voltage Measurement Delta Gap = 0.0040007 m VT = 0.175407184 Vs 14:39:59 Integrated Voltage Measurement... 14:40:18 Voltage Offset Correction: v_off_ini = 0.000004766 V, v_off_fin = -0.000001627 V 14:40:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301740 Vs 14:40:21 Temperature Measurement, Probe Number = 0, T = 20.325000 C 14:40:22 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:40:23 Temperature Measurement, Probe Number = 2, T = 20.060000 C 14:40:23 Temperature Measurement, Probe Number = 3, T = 20.026000 C 14:40:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 14:40:23 Integrated Voltage Measurement... 14:40:43 Voltage Offset Correction: v_off_ini = 0.000001663 V, v_off_fin = 0.000006982 V 14:40:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428996 Vs 14:40:43 Integrated Voltage Measurement... 14:41:03 Voltage Offset Correction: v_off_ini = 0.000006433 V, v_off_fin = -0.000001659 V 14:41:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308724 Vs 14:41:06 Temperature Measurement, Probe Number = 0, T = 20.331000 C 14:41:06 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:41:07 Temperature Measurement, Probe Number = 2, T = 20.059000 C 14:41:07 Temperature Measurement, Probe Number = 3, T = 20.023000 C 14:41:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:41:08 Integrated Voltage Measurement... 14:41:27 Voltage Offset Correction: v_off_ini = 0.000002219 V, v_off_fin = 0.000006834 V 14:41:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438040 Vs 14:41:27 Integrated Voltage Measurement... 14:41:47 Voltage Offset Correction: v_off_ini = 0.000006376 V, v_off_fin = -0.000001027 V 14:41:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308156 Vs 14:41:49 Temperature Measurement, Probe Number = 0, T = 20.345000 C 14:41:50 Temperature Measurement, Probe Number = 1, T = 20.086000 C 14:41:51 Temperature Measurement, Probe Number = 2, T = 20.060000 C 14:41:51 Temperature Measurement, Probe Number = 3, T = 20.024000 C 14:41:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:41:51 Integrated Voltage Measurement... 14:42:11 Voltage Offset Correction: v_off_ini = 0.000001669 V, v_off_fin = 0.000005916 V 14:42:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434628 Vs 14:42:11 Integrated Voltage Measurement... 14:42:39 Voltage Offset Correction: v_off_ini = 0.000005048 V, v_off_fin = 0.000003465 V 14:42:39 Integrated Voltage Measurement Delta Gap = -0.0040004 m VT = -0.175305870 Vs 15:12:42 Temperature Measurement, Probe Number = 0, T = 20.276000 C 15:12:43 Temperature Measurement, Probe Number = 1, T = 20.082000 C 15:12:43 Temperature Measurement, Probe Number = 2, T = 20.053000 C 15:12:44 Temperature Measurement, Probe Number = 3, T = 20.021000 C 15:12:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:12:44 Integrated Voltage Measurement... 15:13:04 Voltage Offset Correction: v_off_ini = 0.000003981 V, v_off_fin = 0.000006177 V 15:13:04 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.175464680 Vs 15:13:04 Integrated Voltage Measurement... 15:13:24 Voltage Offset Correction: v_off_ini = 0.000005000 V, v_off_fin = -0.000001799 V 15:13:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175307826 Vs 15:13:27 Temperature Measurement, Probe Number = 0, T = 20.276000 C 15:13:27 Temperature Measurement, Probe Number = 1, T = 20.082000 C 15:13:28 Temperature Measurement, Probe Number = 2, T = 20.055000 C 15:13:29 Temperature Measurement, Probe Number = 3, T = 20.023000 C 15:13:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:13:29 Integrated Voltage Measurement... 15:13:48 Voltage Offset Correction: v_off_ini = 0.000001188 V, v_off_fin = 0.000005855 V 15:13:48 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175420446 Vs 15:13:48 Integrated Voltage Measurement... 15:14:08 Voltage Offset Correction: v_off_ini = 0.000005252 V, v_off_fin = -0.000002400 V 15:14:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313955 Vs 15:14:10 Temperature Measurement, Probe Number = 0, T = 20.292000 C 15:14:11 Temperature Measurement, Probe Number = 1, T = 20.083000 C 15:14:12 Temperature Measurement, Probe Number = 2, T = 20.053000 C 15:14:12 Temperature Measurement, Probe Number = 3, T = 20.023000 C 15:14:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:14:12 Integrated Voltage Measurement... 15:14:32 Voltage Offset Correction: v_off_ini = 0.000002013 V, v_off_fin = 0.000005920 V 15:14:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425176 Vs 15:14:32 Integrated Voltage Measurement... 15:14:52 Voltage Offset Correction: v_off_ini = 0.000005183 V, v_off_fin = -0.000002415 V 15:14:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314647 Vs 15:14:54 Temperature Measurement, Probe Number = 0, T = 20.228000 C 15:14:55 Temperature Measurement, Probe Number = 1, T = 20.079000 C 15:14:56 Temperature Measurement, Probe Number = 2, T = 20.044000 C 15:14:56 Temperature Measurement, Probe Number = 3, T = 20.017000 C 15:14:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:14:56 Integrated Voltage Measurement... 15:15:16 Voltage Offset Correction: v_off_ini = 0.000001378 V, v_off_fin = 0.000006190 V 15:15:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175434923 Vs 15:15:17 Integrated Voltage Measurement... 15:15:36 Voltage Offset Correction: v_off_ini = 0.000005870 V, v_off_fin = -0.000002081 V 15:15:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299962 Vs 15:15:39 Temperature Measurement, Probe Number = 0, T = 20.202000 C 15:15:39 Temperature Measurement, Probe Number = 1, T = 20.077000 C 15:15:40 Temperature Measurement, Probe Number = 2, T = 20.043000 C 15:15:40 Temperature Measurement, Probe Number = 3, T = 20.017000 C 15:15:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:15:41 Integrated Voltage Measurement... 15:16:00 Voltage Offset Correction: v_off_ini = 0.000001004 V, v_off_fin = 0.000006546 V 15:16:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443495 Vs 15:16:00 Integrated Voltage Measurement... 15:16:20 Voltage Offset Correction: v_off_ini = 0.000005922 V, v_off_fin = -0.000001894 V 15:16:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301662 Vs 15:16:23 Temperature Measurement, Probe Number = 0, T = 20.166000 C 15:16:23 Temperature Measurement, Probe Number = 1, T = 20.073000 C 15:16:24 Temperature Measurement, Probe Number = 2, T = 20.046000 C 15:16:25 Temperature Measurement, Probe Number = 3, T = 20.018000 C 15:16:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:16:25 Integrated Voltage Measurement... 15:16:44 Voltage Offset Correction: v_off_ini = 0.000001263 V, v_off_fin = 0.000006820 V 15:16:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435195 Vs 15:16:44 Integrated Voltage Measurement... 15:17:03 Voltage Offset Correction: v_off_ini = 0.000005987 V, v_off_fin = -0.000002065 V 15:17:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307776 Vs 15:17:06 Temperature Measurement, Probe Number = 0, T = 20.112000 C 15:17:07 Temperature Measurement, Probe Number = 1, T = 20.077000 C 15:17:07 Temperature Measurement, Probe Number = 2, T = 20.050000 C 15:17:08 Temperature Measurement, Probe Number = 3, T = 20.021000 C 15:17:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:17:08 Integrated Voltage Measurement... 15:17:27 Voltage Offset Correction: v_off_ini = 0.000001787 V, v_off_fin = 0.000006428 V 15:17:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439312 Vs 15:17:27 Integrated Voltage Measurement... 15:17:48 Voltage Offset Correction: v_off_ini = 0.000005642 V, v_off_fin = 0.000000355 V 15:17:48 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175314766 Vs 15:17:51 Temperature Measurement, Probe Number = 0, T = 20.119000 C 15:17:52 Temperature Measurement, Probe Number = 1, T = 20.078000 C 15:17:52 Temperature Measurement, Probe Number = 2, T = 20.047000 C 15:17:53 Temperature Measurement, Probe Number = 3, T = 20.019000 C 15:17:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:17:53 Integrated Voltage Measurement... 15:18:12 Voltage Offset Correction: v_off_ini = 0.000003033 V, v_off_fin = 0.000007080 V 15:18:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175433706 Vs 15:18:12 Integrated Voltage Measurement... 15:18:31 Voltage Offset Correction: v_off_ini = 0.000006167 V, v_off_fin = -0.000001795 V 15:18:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304617 Vs 15:18:34 Temperature Measurement, Probe Number = 0, T = 20.120000 C 15:18:35 Temperature Measurement, Probe Number = 1, T = 20.078000 C 15:18:35 Temperature Measurement, Probe Number = 2, T = 20.047000 C 15:18:36 Temperature Measurement, Probe Number = 3, T = 20.020000 C 15:18:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:18:36 Integrated Voltage Measurement... 15:18:55 Voltage Offset Correction: v_off_ini = 0.000002183 V, v_off_fin = 0.000006877 V 15:18:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450476 Vs 15:18:56 Integrated Voltage Measurement... 15:19:16 Voltage Offset Correction: v_off_ini = 0.000005967 V, v_off_fin = 0.000000174 V 15:19:16 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175303524 Vs 15:19:19 Temperature Measurement, Probe Number = 0, T = 20.049000 C 15:19:20 Temperature Measurement, Probe Number = 1, T = 20.078000 C 15:19:20 Temperature Measurement, Probe Number = 2, T = 20.048000 C 15:19:21 Temperature Measurement, Probe Number = 3, T = 20.019000 C 15:19:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:19:21 Integrated Voltage Measurement... 15:19:40 Voltage Offset Correction: v_off_ini = 0.000002892 V, v_off_fin = 0.000006849 V 15:19:40 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175430995 Vs 15:19:41 Integrated Voltage Measurement... 15:20:00 Voltage Offset Correction: v_off_ini = 0.000005713 V, v_off_fin = -0.000001216 V 15:20:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314156 Vs 15:50:02 Temperature Measurement, Probe Number = 0, T = 20.170000 C 15:50:03 Temperature Measurement, Probe Number = 1, T = 20.069000 C 15:50:04 Temperature Measurement, Probe Number = 2, T = 20.034000 C 15:50:04 Temperature Measurement, Probe Number = 3, T = 20.011000 C 15:50:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:50:05 Integrated Voltage Measurement... 15:50:24 Voltage Offset Correction: v_off_ini = 0.000005092 V, v_off_fin = 0.000006490 V 15:50:24 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175540093 Vs 15:50:24 Integrated Voltage Measurement... 15:50:43 Voltage Offset Correction: v_off_ini = 0.000005860 V, v_off_fin = -0.000001432 V 15:50:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312645 Vs 15:50:46 Temperature Measurement, Probe Number = 0, T = 20.188000 C 15:50:47 Temperature Measurement, Probe Number = 1, T = 20.073000 C 15:50:47 Temperature Measurement, Probe Number = 2, T = 20.041000 C 15:50:48 Temperature Measurement, Probe Number = 3, T = 20.017000 C 15:50:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:50:48 Integrated Voltage Measurement... 15:51:07 Voltage Offset Correction: v_off_ini = 0.000002224 V, v_off_fin = 0.000006491 V 15:51:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444220 Vs 15:51:07 Integrated Voltage Measurement... 15:51:27 Voltage Offset Correction: v_off_ini = 0.000005792 V, v_off_fin = -0.000000715 V 15:51:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304526 Vs 15:51:30 Temperature Measurement, Probe Number = 0, T = 20.210000 C 15:51:31 Temperature Measurement, Probe Number = 1, T = 20.074000 C 15:51:31 Temperature Measurement, Probe Number = 2, T = 20.042000 C 15:51:32 Temperature Measurement, Probe Number = 3, T = 20.020000 C 15:51:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:51:32 Integrated Voltage Measurement... 15:51:51 Voltage Offset Correction: v_off_ini = 0.000002965 V, v_off_fin = 0.000006518 V 15:51:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175437727 Vs 15:51:52 Integrated Voltage Measurement... 15:52:10 Voltage Offset Correction: v_off_ini = 0.000005919 V, v_off_fin = -0.000000958 V 15:52:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304739 Vs 15:52:13 Temperature Measurement, Probe Number = 0, T = 20.169000 C 15:52:14 Temperature Measurement, Probe Number = 1, T = 20.077000 C 15:52:15 Temperature Measurement, Probe Number = 2, T = 20.049000 C 15:52:15 Temperature Measurement, Probe Number = 3, T = 20.024000 C 15:52:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:52:15 Integrated Voltage Measurement... 15:52:35 Voltage Offset Correction: v_off_ini = 0.000002466 V, v_off_fin = 0.000007159 V 15:52:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175447090 Vs 15:52:35 Integrated Voltage Measurement... 15:52:54 Voltage Offset Correction: v_off_ini = 0.000005821 V, v_off_fin = -0.000001614 V 15:52:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305300 Vs 15:52:57 Temperature Measurement, Probe Number = 0, T = 20.201000 C 15:52:58 Temperature Measurement, Probe Number = 1, T = 20.078000 C 15:52:58 Temperature Measurement, Probe Number = 2, T = 20.047000 C 15:52:59 Temperature Measurement, Probe Number = 3, T = 20.026000 C 15:52:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 15:52:59 Integrated Voltage Measurement... 15:53:18 Voltage Offset Correction: v_off_ini = 0.000002355 V, v_off_fin = 0.000006570 V 15:53:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442949 Vs 15:53:19 Integrated Voltage Measurement... 15:53:38 Voltage Offset Correction: v_off_ini = 0.000005893 V, v_off_fin = -0.000002631 V 15:53:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310999 Vs 15:53:40 Temperature Measurement, Probe Number = 0, T = 20.241000 C 15:53:41 Temperature Measurement, Probe Number = 1, T = 20.080000 C 15:53:42 Temperature Measurement, Probe Number = 2, T = 20.045000 C 15:53:42 Temperature Measurement, Probe Number = 3, T = 20.021000 C 15:53:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:53:42 Integrated Voltage Measurement... 15:54:02 Voltage Offset Correction: v_off_ini = 0.000001889 V, v_off_fin = 0.000006707 V 15:54:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447750 Vs 15:54:02 Integrated Voltage Measurement... 15:54:21 Voltage Offset Correction: v_off_ini = 0.000005932 V, v_off_fin = -0.000001546 V 15:54:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317988 Vs 15:54:24 Temperature Measurement, Probe Number = 0, T = 20.258000 C 15:54:25 Temperature Measurement, Probe Number = 1, T = 20.078000 C 15:54:25 Temperature Measurement, Probe Number = 2, T = 20.048000 C 15:54:26 Temperature Measurement, Probe Number = 3, T = 20.019000 C 15:54:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:54:26 Integrated Voltage Measurement... 15:54:45 Voltage Offset Correction: v_off_ini = 0.000002159 V, v_off_fin = 0.000006545 V 15:54:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437769 Vs 15:54:45 Integrated Voltage Measurement... 15:55:06 Voltage Offset Correction: v_off_ini = 0.000005343 V, v_off_fin = -0.000000368 V 15:55:06 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310129 Vs 15:55:09 Temperature Measurement, Probe Number = 0, T = 20.275000 C 15:55:10 Temperature Measurement, Probe Number = 1, T = 20.076000 C 15:55:10 Temperature Measurement, Probe Number = 2, T = 20.050000 C 15:55:11 Temperature Measurement, Probe Number = 3, T = 20.019000 C 15:55:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:55:11 Integrated Voltage Measurement... 15:55:31 Voltage Offset Correction: v_off_ini = 0.000002477 V, v_off_fin = 0.000006344 V 15:55:31 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175425071 Vs 15:55:31 Integrated Voltage Measurement... 15:55:50 Voltage Offset Correction: v_off_ini = 0.000005822 V, v_off_fin = -0.000001494 V 15:55:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301558 Vs 15:55:53 Temperature Measurement, Probe Number = 0, T = 20.328000 C 15:55:53 Temperature Measurement, Probe Number = 1, T = 20.073000 C 15:55:54 Temperature Measurement, Probe Number = 2, T = 20.049000 C 15:55:55 Temperature Measurement, Probe Number = 3, T = 20.018000 C 15:55:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:55:55 Integrated Voltage Measurement... 15:56:14 Voltage Offset Correction: v_off_ini = 0.000001815 V, v_off_fin = 0.000006962 V 15:56:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446369 Vs 15:56:14 Integrated Voltage Measurement... 15:56:34 Voltage Offset Correction: v_off_ini = 0.000005957 V, v_off_fin = -0.000001996 V 15:56:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312036 Vs 15:56:36 Temperature Measurement, Probe Number = 0, T = 20.344000 C 15:56:37 Temperature Measurement, Probe Number = 1, T = 20.075000 C 15:56:38 Temperature Measurement, Probe Number = 2, T = 20.049000 C 15:56:38 Temperature Measurement, Probe Number = 3, T = 20.021000 C 15:56:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 15:56:38 Integrated Voltage Measurement... 15:56:58 Voltage Offset Correction: v_off_ini = 0.000001711 V, v_off_fin = 0.000006770 V 15:56:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175446854 Vs 15:56:58 Integrated Voltage Measurement... 15:57:18 Voltage Offset Correction: v_off_ini = 0.000005767 V, v_off_fin = -0.000000974 V 15:57:18 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309601 Vs 16:27:21 Temperature Measurement, Probe Number = 0, T = 20.227000 C 16:27:21 Temperature Measurement, Probe Number = 1, T = 20.066000 C 16:27:22 Temperature Measurement, Probe Number = 2, T = 20.038000 C 16:27:22 Temperature Measurement, Probe Number = 3, T = 20.010000 C 16:27:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:27:23 Integrated Voltage Measurement... 16:27:42 Voltage Offset Correction: v_off_ini = 0.000004541 V, v_off_fin = 0.000006718 V 16:27:42 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175520435 Vs 16:27:42 Integrated Voltage Measurement... 16:28:01 Voltage Offset Correction: v_off_ini = 0.000005691 V, v_off_fin = -0.000002561 V 16:28:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319040 Vs 16:28:04 Temperature Measurement, Probe Number = 0, T = 20.254000 C 16:28:05 Temperature Measurement, Probe Number = 1, T = 20.068000 C 16:28:05 Temperature Measurement, Probe Number = 2, T = 20.041000 C 16:28:06 Temperature Measurement, Probe Number = 3, T = 20.012000 C 16:28:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:28:06 Integrated Voltage Measurement... 16:28:25 Voltage Offset Correction: v_off_ini = 0.000002101 V, v_off_fin = 0.000006646 V 16:28:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445798 Vs 16:28:26 Integrated Voltage Measurement... 16:28:45 Voltage Offset Correction: v_off_ini = 0.000005485 V, v_off_fin = -0.000002250 V 16:28:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314953 Vs 16:28:48 Temperature Measurement, Probe Number = 0, T = 20.220000 C 16:28:48 Temperature Measurement, Probe Number = 1, T = 20.069000 C 16:28:49 Temperature Measurement, Probe Number = 2, T = 20.042000 C 16:28:50 Temperature Measurement, Probe Number = 3, T = 20.012000 C 16:28:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:28:50 Integrated Voltage Measurement... 16:29:09 Voltage Offset Correction: v_off_ini = 0.000002357 V, v_off_fin = 0.000006451 V 16:29:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453073 Vs 16:29:09 Integrated Voltage Measurement... 16:29:29 Voltage Offset Correction: v_off_ini = 0.000005683 V, v_off_fin = -0.000001612 V 16:29:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317605 Vs 16:29:31 Temperature Measurement, Probe Number = 0, T = 20.178000 C 16:29:32 Temperature Measurement, Probe Number = 1, T = 20.065000 C 16:29:33 Temperature Measurement, Probe Number = 2, T = 20.040000 C 16:29:33 Temperature Measurement, Probe Number = 3, T = 20.013000 C 16:29:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:29:34 Integrated Voltage Measurement... 16:29:53 Voltage Offset Correction: v_off_ini = 0.000001608 V, v_off_fin = 0.000006155 V 16:29:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444650 Vs 16:29:53 Integrated Voltage Measurement... 16:30:13 Voltage Offset Correction: v_off_ini = 0.000005012 V, v_off_fin = -0.000001645 V 16:30:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175327670 Vs 16:30:15 Temperature Measurement, Probe Number = 0, T = 20.099000 C 16:30:16 Temperature Measurement, Probe Number = 1, T = 20.064000 C 16:30:17 Temperature Measurement, Probe Number = 2, T = 20.040000 C 16:30:17 Temperature Measurement, Probe Number = 3, T = 20.010000 C 16:30:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:30:18 Integrated Voltage Measurement... 16:30:37 Voltage Offset Correction: v_off_ini = 0.000002672 V, v_off_fin = 0.000006693 V 16:30:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175452944 Vs 16:30:37 Integrated Voltage Measurement... 16:30:56 Voltage Offset Correction: v_off_ini = 0.000005585 V, v_off_fin = -0.000002038 V 16:30:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317839 Vs 16:30:59 Temperature Measurement, Probe Number = 0, T = 20.068000 C 16:31:00 Temperature Measurement, Probe Number = 1, T = 20.064000 C 16:31:00 Temperature Measurement, Probe Number = 2, T = 20.039000 C 16:31:01 Temperature Measurement, Probe Number = 3, T = 20.012000 C 16:31:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:31:01 Integrated Voltage Measurement... 16:31:20 Voltage Offset Correction: v_off_ini = 0.000001858 V, v_off_fin = 0.000007065 V 16:31:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175449705 Vs 16:31:20 Integrated Voltage Measurement... 16:31:39 Voltage Offset Correction: v_off_ini = 0.000005825 V, v_off_fin = -0.000000609 V 16:31:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306528 Vs 16:31:42 Temperature Measurement, Probe Number = 0, T = 20.103000 C 16:31:43 Temperature Measurement, Probe Number = 1, T = 20.060000 C 16:31:43 Temperature Measurement, Probe Number = 2, T = 20.031000 C 16:31:44 Temperature Measurement, Probe Number = 3, T = 20.005000 C 16:31:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:31:44 Integrated Voltage Measurement... 16:32:03 Voltage Offset Correction: v_off_ini = 0.000001321 V, v_off_fin = 0.000006857 V 16:32:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175457665 Vs 16:32:03 Integrated Voltage Measurement... 16:32:23 Voltage Offset Correction: v_off_ini = 0.000005965 V, v_off_fin = -0.000001398 V 16:32:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320428 Vs 16:32:26 Temperature Measurement, Probe Number = 0, T = 20.045000 C 16:32:26 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:32:27 Temperature Measurement, Probe Number = 2, T = 20.031000 C 16:32:28 Temperature Measurement, Probe Number = 3, T = 20.005000 C 16:32:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:32:28 Integrated Voltage Measurement... 16:32:47 Voltage Offset Correction: v_off_ini = 0.000002172 V, v_off_fin = 0.000006608 V 16:32:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175449110 Vs 16:32:48 Integrated Voltage Measurement... 16:33:07 Voltage Offset Correction: v_off_ini = 0.000006020 V, v_off_fin = -0.000001448 V 16:33:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310014 Vs 16:33:10 Temperature Measurement, Probe Number = 0, T = 20.121000 C 16:33:11 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:33:11 Temperature Measurement, Probe Number = 2, T = 20.038000 C 16:33:12 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:33:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:33:12 Integrated Voltage Measurement... 16:33:31 Voltage Offset Correction: v_off_ini = 0.000001818 V, v_off_fin = 0.000007502 V 16:33:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175448665 Vs 16:33:31 Integrated Voltage Measurement... 16:33:50 Voltage Offset Correction: v_off_ini = 0.000006242 V, v_off_fin = -0.000000898 V 16:33:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308462 Vs 16:33:53 Temperature Measurement, Probe Number = 0, T = 20.166000 C 16:33:54 Temperature Measurement, Probe Number = 1, T = 20.065000 C 16:33:54 Temperature Measurement, Probe Number = 2, T = 20.039000 C 16:33:55 Temperature Measurement, Probe Number = 3, T = 20.011000 C 16:33:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:33:55 Integrated Voltage Measurement... 16:34:14 Voltage Offset Correction: v_off_ini = 0.000001722 V, v_off_fin = 0.000006282 V 16:34:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448236 Vs 16:34:15 Integrated Voltage Measurement... 16:34:34 Voltage Offset Correction: v_off_ini = 0.000005649 V, v_off_fin = -0.000002322 V 16:34:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324804 Vs 17:04:37 Temperature Measurement, Probe Number = 0, T = 20.289000 C 17:04:38 Temperature Measurement, Probe Number = 1, T = 20.066000 C 17:04:38 Temperature Measurement, Probe Number = 2, T = 20.040000 C 17:04:39 Temperature Measurement, Probe Number = 3, T = 20.009000 C 17:04:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:04:39 Integrated Voltage Measurement... 17:04:58 Voltage Offset Correction: v_off_ini = 0.000004257 V, v_off_fin = 0.000007290 V 17:04:58 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175544175 Vs 17:04:58 Integrated Voltage Measurement... 17:05:17 Voltage Offset Correction: v_off_ini = 0.000006301 V, v_off_fin = -0.000001117 V 17:05:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305114 Vs 17:05:20 Temperature Measurement, Probe Number = 0, T = 20.268000 C 17:05:21 Temperature Measurement, Probe Number = 1, T = 20.067000 C 17:05:21 Temperature Measurement, Probe Number = 2, T = 20.041000 C 17:05:22 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:05:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:05:22 Integrated Voltage Measurement... 17:05:42 Voltage Offset Correction: v_off_ini = 0.000002381 V, v_off_fin = 0.000006695 V 17:05:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453447 Vs 17:05:42 Integrated Voltage Measurement... 17:06:01 Voltage Offset Correction: v_off_ini = 0.000005806 V, v_off_fin = -0.000001935 V 17:06:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307918 Vs 17:06:04 Temperature Measurement, Probe Number = 0, T = 20.228000 C 17:06:05 Temperature Measurement, Probe Number = 1, T = 20.065000 C 17:06:06 Temperature Measurement, Probe Number = 2, T = 20.041000 C 17:06:06 Temperature Measurement, Probe Number = 3, T = 20.011000 C 17:06:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:06:06 Integrated Voltage Measurement... 17:06:27 Voltage Offset Correction: v_off_ini = 0.000001895 V, v_off_fin = 0.000006338 V 17:06:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453361 Vs 17:06:27 Integrated Voltage Measurement... 17:06:47 Voltage Offset Correction: v_off_ini = 0.000005345 V, v_off_fin = -0.000001900 V 17:06:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310297 Vs 17:06:49 Temperature Measurement, Probe Number = 0, T = 20.170000 C 17:06:50 Temperature Measurement, Probe Number = 1, T = 20.066000 C 17:06:51 Temperature Measurement, Probe Number = 2, T = 20.035000 C 17:06:51 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:06:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:06:52 Integrated Voltage Measurement... 17:07:11 Voltage Offset Correction: v_off_ini = 0.000001725 V, v_off_fin = 0.000006580 V 17:07:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450632 Vs 17:07:11 Integrated Voltage Measurement... 17:07:30 Voltage Offset Correction: v_off_ini = 0.000005689 V, v_off_fin = -0.000001484 V 17:07:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309810 Vs 17:07:33 Temperature Measurement, Probe Number = 0, T = 20.185000 C 17:07:34 Temperature Measurement, Probe Number = 1, T = 20.063000 C 17:07:34 Temperature Measurement, Probe Number = 2, T = 20.037000 C 17:07:35 Temperature Measurement, Probe Number = 3, T = 20.003000 C 17:07:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 17:07:35 Integrated Voltage Measurement... 17:07:54 Voltage Offset Correction: v_off_ini = 0.000001752 V, v_off_fin = 0.000006231 V 17:07:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442317 Vs 17:07:55 Integrated Voltage Measurement... 17:08:14 Voltage Offset Correction: v_off_ini = 0.000005142 V, v_off_fin = -0.000002842 V 17:08:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313117 Vs 17:08:16 Temperature Measurement, Probe Number = 0, T = 20.246000 C 17:08:17 Temperature Measurement, Probe Number = 1, T = 20.065000 C 17:08:18 Temperature Measurement, Probe Number = 2, T = 20.040000 C 17:08:18 Temperature Measurement, Probe Number = 3, T = 20.006000 C 17:08:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:08:18 Integrated Voltage Measurement... 17:08:38 Voltage Offset Correction: v_off_ini = 0.000001617 V, v_off_fin = 0.000006384 V 17:08:38 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175439935 Vs 17:08:38 Integrated Voltage Measurement... 17:08:57 Voltage Offset Correction: v_off_ini = 0.000005370 V, v_off_fin = -0.000001366 V 17:08:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317545 Vs 17:09:00 Temperature Measurement, Probe Number = 0, T = 20.277000 C 17:09:01 Temperature Measurement, Probe Number = 1, T = 20.064000 C 17:09:01 Temperature Measurement, Probe Number = 2, T = 20.040000 C 17:09:02 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:09:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:09:02 Integrated Voltage Measurement... 17:09:21 Voltage Offset Correction: v_off_ini = 0.000001056 V, v_off_fin = 0.000006249 V 17:09:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438783 Vs 17:09:21 Integrated Voltage Measurement... 17:09:40 Voltage Offset Correction: v_off_ini = 0.000005231 V, v_off_fin = -0.000001534 V 17:09:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317684 Vs 17:09:43 Temperature Measurement, Probe Number = 0, T = 20.237000 C 17:09:44 Temperature Measurement, Probe Number = 1, T = 20.066000 C 17:09:45 Temperature Measurement, Probe Number = 2, T = 20.043000 C 17:09:45 Temperature Measurement, Probe Number = 3, T = 20.011000 C 17:09:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:09:45 Integrated Voltage Measurement... 17:10:05 Voltage Offset Correction: v_off_ini = 0.000001105 V, v_off_fin = 0.000006322 V 17:10:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438020 Vs 17:10:05 Integrated Voltage Measurement... 17:10:24 Voltage Offset Correction: v_off_ini = 0.000004590 V, v_off_fin = -0.000002420 V 17:10:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316165 Vs 17:10:27 Temperature Measurement, Probe Number = 0, T = 20.246000 C 17:10:27 Temperature Measurement, Probe Number = 1, T = 20.065000 C 17:10:28 Temperature Measurement, Probe Number = 2, T = 20.041000 C 17:10:29 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:10:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:10:29 Integrated Voltage Measurement... 17:10:48 Voltage Offset Correction: v_off_ini = 0.000001224 V, v_off_fin = 0.000006356 V 17:10:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175444118 Vs 17:10:48 Integrated Voltage Measurement... 17:11:07 Voltage Offset Correction: v_off_ini = 0.000005959 V, v_off_fin = -0.000001962 V 17:11:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312792 Vs 17:11:10 Temperature Measurement, Probe Number = 0, T = 20.254000 C 17:11:11 Temperature Measurement, Probe Number = 1, T = 20.067000 C 17:11:11 Temperature Measurement, Probe Number = 2, T = 20.040000 C 17:11:12 Temperature Measurement, Probe Number = 3, T = 20.009000 C 17:11:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:11:12 Integrated Voltage Measurement... 17:11:31 Voltage Offset Correction: v_off_ini = 0.000001716 V, v_off_fin = 0.000006085 V 17:11:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438257 Vs 17:11:32 Integrated Voltage Measurement... 17:11:51 Voltage Offset Correction: v_off_ini = 0.000005293 V, v_off_fin = -0.000002361 V 17:11:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309828 Vs 17:41:53 Temperature Measurement, Probe Number = 0, T = 20.287000 C 17:41:54 Temperature Measurement, Probe Number = 1, T = 20.063000 C 17:41:55 Temperature Measurement, Probe Number = 2, T = 20.040000 C 17:41:55 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:41:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:41:56 Integrated Voltage Measurement... 17:42:15 Voltage Offset Correction: v_off_ini = 0.000003171 V, v_off_fin = 0.000006611 V 17:42:15 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175534886 Vs 17:42:15 Integrated Voltage Measurement... 17:42:34 Voltage Offset Correction: v_off_ini = 0.000005722 V, v_off_fin = -0.000001410 V 17:42:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313441 Vs 17:42:37 Temperature Measurement, Probe Number = 0, T = 20.300000 C 17:42:38 Temperature Measurement, Probe Number = 1, T = 20.065000 C 17:42:38 Temperature Measurement, Probe Number = 2, T = 20.041000 C 17:42:39 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:42:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:42:39 Integrated Voltage Measurement... 17:42:58 Voltage Offset Correction: v_off_ini = 0.000002051 V, v_off_fin = 0.000006764 V 17:42:59 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440250 Vs 17:42:59 Integrated Voltage Measurement... 17:43:18 Voltage Offset Correction: v_off_ini = 0.000005970 V, v_off_fin = -0.000001688 V 17:43:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307763 Vs 17:43:20 Temperature Measurement, Probe Number = 0, T = 20.301000 C 17:43:21 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:43:22 Temperature Measurement, Probe Number = 2, T = 20.039000 C 17:43:22 Temperature Measurement, Probe Number = 3, T = 20.011000 C 17:43:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:43:23 Integrated Voltage Measurement... 17:43:42 Voltage Offset Correction: v_off_ini = 0.000001716 V, v_off_fin = 0.000005817 V 17:43:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441210 Vs 17:43:43 Integrated Voltage Measurement... 17:44:02 Voltage Offset Correction: v_off_ini = 0.000005545 V, v_off_fin = -0.000001869 V 17:44:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311307 Vs 17:44:04 Temperature Measurement, Probe Number = 0, T = 20.285000 C 17:44:05 Temperature Measurement, Probe Number = 1, T = 20.061000 C 17:44:06 Temperature Measurement, Probe Number = 2, T = 20.038000 C 17:44:06 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:44:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:44:07 Integrated Voltage Measurement... 17:44:26 Voltage Offset Correction: v_off_ini = 0.000001355 V, v_off_fin = 0.000006131 V 17:44:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436192 Vs 17:44:26 Integrated Voltage Measurement... 17:44:45 Voltage Offset Correction: v_off_ini = 0.000005425 V, v_off_fin = -0.000002123 V 17:44:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319384 Vs 17:44:48 Temperature Measurement, Probe Number = 0, T = 20.343000 C 17:44:49 Temperature Measurement, Probe Number = 1, T = 20.063000 C 17:44:50 Temperature Measurement, Probe Number = 2, T = 20.038000 C 17:44:50 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:44:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:44:50 Integrated Voltage Measurement... 17:45:10 Voltage Offset Correction: v_off_ini = 0.000000995 V, v_off_fin = 0.000005928 V 17:45:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431250 Vs 17:45:10 Integrated Voltage Measurement... 17:45:30 Voltage Offset Correction: v_off_ini = 0.000005513 V, v_off_fin = -0.000001730 V 17:45:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305116 Vs 17:45:32 Temperature Measurement, Probe Number = 0, T = 20.349000 C 17:45:33 Temperature Measurement, Probe Number = 1, T = 20.065000 C 17:45:34 Temperature Measurement, Probe Number = 2, T = 20.037000 C 17:45:34 Temperature Measurement, Probe Number = 3, T = 20.009000 C 17:45:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:45:35 Integrated Voltage Measurement... 17:45:54 Voltage Offset Correction: v_off_ini = 0.000001641 V, v_off_fin = 0.000006250 V 17:45:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433709 Vs 17:45:54 Integrated Voltage Measurement... 17:46:13 Voltage Offset Correction: v_off_ini = 0.000005418 V, v_off_fin = -0.000002392 V 17:46:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309620 Vs 17:46:16 Temperature Measurement, Probe Number = 0, T = 20.323000 C 17:46:16 Temperature Measurement, Probe Number = 1, T = 20.064000 C 17:46:17 Temperature Measurement, Probe Number = 2, T = 20.038000 C 17:46:18 Temperature Measurement, Probe Number = 3, T = 20.007000 C 17:46:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:46:18 Integrated Voltage Measurement... 17:46:37 Voltage Offset Correction: v_off_ini = 0.000001038 V, v_off_fin = 0.000006530 V 17:46:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433767 Vs 17:46:37 Integrated Voltage Measurement... 17:46:57 Voltage Offset Correction: v_off_ini = 0.000006230 V, v_off_fin = -0.000001417 V 17:46:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314280 Vs 17:46:59 Temperature Measurement, Probe Number = 0, T = 20.280000 C 17:47:00 Temperature Measurement, Probe Number = 1, T = 20.069000 C 17:47:01 Temperature Measurement, Probe Number = 2, T = 20.039000 C 17:47:01 Temperature Measurement, Probe Number = 3, T = 20.008000 C 17:47:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:47:02 Integrated Voltage Measurement... 17:47:21 Voltage Offset Correction: v_off_ini = 0.000002339 V, v_off_fin = 0.000005860 V 17:47:21 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437471 Vs 17:47:21 Integrated Voltage Measurement... 17:47:40 Voltage Offset Correction: v_off_ini = 0.000005503 V, v_off_fin = -0.000002093 V 17:47:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308853 Vs 17:47:43 Temperature Measurement, Probe Number = 0, T = 20.302000 C 17:47:44 Temperature Measurement, Probe Number = 1, T = 20.068000 C 17:47:44 Temperature Measurement, Probe Number = 2, T = 20.037000 C 17:47:45 Temperature Measurement, Probe Number = 3, T = 20.011000 C 17:47:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:47:45 Integrated Voltage Measurement... 17:48:04 Voltage Offset Correction: v_off_ini = 0.000002189 V, v_off_fin = 0.000006218 V 17:48:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434893 Vs 17:48:04 Integrated Voltage Measurement... 17:48:24 Voltage Offset Correction: v_off_ini = 0.000005249 V, v_off_fin = -0.000002072 V 17:48:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316026 Vs 17:48:27 Temperature Measurement, Probe Number = 0, T = 20.288000 C 17:48:27 Temperature Measurement, Probe Number = 1, T = 20.064000 C 17:48:28 Temperature Measurement, Probe Number = 2, T = 20.034000 C 17:48:29 Temperature Measurement, Probe Number = 3, T = 20.008000 C 17:48:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:48:29 Integrated Voltage Measurement... 17:48:48 Voltage Offset Correction: v_off_ini = 0.000001927 V, v_off_fin = 0.000005970 V 17:48:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436692 Vs 17:48:48 Integrated Voltage Measurement... 17:49:07 Voltage Offset Correction: v_off_ini = 0.000005618 V, v_off_fin = -0.000001794 V 17:49:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305910 Vs 18:19:10 Temperature Measurement, Probe Number = 0, T = 20.244000 C 18:19:11 Temperature Measurement, Probe Number = 1, T = 20.069000 C 18:19:11 Temperature Measurement, Probe Number = 2, T = 20.041000 C 18:19:12 Temperature Measurement, Probe Number = 3, T = 20.014000 C 18:19:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:19:12 Integrated Voltage Measurement... 18:19:31 Voltage Offset Correction: v_off_ini = 0.000004319 V, v_off_fin = 0.000006349 V 18:19:32 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175533776 Vs 18:19:32 Integrated Voltage Measurement... 18:19:51 Voltage Offset Correction: v_off_ini = 0.000005677 V, v_off_fin = -0.000002479 V 18:19:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307581 Vs 18:19:54 Temperature Measurement, Probe Number = 0, T = 20.278000 C 18:19:54 Temperature Measurement, Probe Number = 1, T = 20.070000 C 18:19:55 Temperature Measurement, Probe Number = 2, T = 20.044000 C 18:19:55 Temperature Measurement, Probe Number = 3, T = 20.014000 C 18:19:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:19:56 Integrated Voltage Measurement... 18:20:15 Voltage Offset Correction: v_off_ini = 0.000001358 V, v_off_fin = 0.000006099 V 18:20:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433809 Vs 18:20:15 Integrated Voltage Measurement... 18:20:35 Voltage Offset Correction: v_off_ini = 0.000005509 V, v_off_fin = -0.000002387 V 18:20:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318457 Vs 18:20:38 Temperature Measurement, Probe Number = 0, T = 20.292000 C 18:20:38 Temperature Measurement, Probe Number = 1, T = 20.069000 C 18:20:39 Temperature Measurement, Probe Number = 2, T = 20.038000 C 18:20:40 Temperature Measurement, Probe Number = 3, T = 20.012000 C 18:20:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:20:40 Integrated Voltage Measurement... 18:20:59 Voltage Offset Correction: v_off_ini = 0.000001704 V, v_off_fin = 0.000006231 V 18:20:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439829 Vs 18:20:59 Integrated Voltage Measurement... 18:21:18 Voltage Offset Correction: v_off_ini = 0.000005599 V, v_off_fin = -0.000001847 V 18:21:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304013 Vs 18:21:21 Temperature Measurement, Probe Number = 0, T = 20.269000 C 18:21:22 Temperature Measurement, Probe Number = 1, T = 20.067000 C 18:21:22 Temperature Measurement, Probe Number = 2, T = 20.035000 C 18:21:23 Temperature Measurement, Probe Number = 3, T = 20.012000 C 18:21:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:21:23 Integrated Voltage Measurement... 18:21:42 Voltage Offset Correction: v_off_ini = 0.000001968 V, v_off_fin = 0.000006571 V 18:21:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435832 Vs 18:21:43 Integrated Voltage Measurement... 18:22:02 Voltage Offset Correction: v_off_ini = 0.000006112 V, v_off_fin = -0.000001496 V 18:22:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300906 Vs 18:22:05 Temperature Measurement, Probe Number = 0, T = 20.276000 C 18:22:05 Temperature Measurement, Probe Number = 1, T = 20.068000 C 18:22:06 Temperature Measurement, Probe Number = 2, T = 20.037000 C 18:22:07 Temperature Measurement, Probe Number = 3, T = 20.016000 C 18:22:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 18:22:07 Integrated Voltage Measurement... 18:22:26 Voltage Offset Correction: v_off_ini = 0.000002124 V, v_off_fin = 0.000006622 V 18:22:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438443 Vs 18:22:26 Integrated Voltage Measurement... 18:22:45 Voltage Offset Correction: v_off_ini = 0.000005931 V, v_off_fin = -0.000000553 V 18:22:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301803 Vs 18:22:48 Temperature Measurement, Probe Number = 0, T = 20.284000 C 18:22:49 Temperature Measurement, Probe Number = 1, T = 20.065000 C 18:22:49 Temperature Measurement, Probe Number = 2, T = 20.034000 C 18:22:50 Temperature Measurement, Probe Number = 3, T = 20.010000 C 18:22:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 18:22:50 Integrated Voltage Measurement... 18:23:09 Voltage Offset Correction: v_off_ini = 0.000002115 V, v_off_fin = 0.000006576 V 18:23:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443280 Vs 18:23:10 Integrated Voltage Measurement... 18:23:29 Voltage Offset Correction: v_off_ini = 0.000005992 V, v_off_fin = -0.000001761 V 18:23:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308411 Vs 18:23:32 Temperature Measurement, Probe Number = 0, T = 20.192000 C 18:23:32 Temperature Measurement, Probe Number = 1, T = 20.064000 C 18:23:33 Temperature Measurement, Probe Number = 2, T = 20.036000 C 18:23:34 Temperature Measurement, Probe Number = 3, T = 20.010000 C 18:23:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:23:34 Integrated Voltage Measurement... 18:23:53 Voltage Offset Correction: v_off_ini = 0.000002297 V, v_off_fin = 0.000006355 V 18:23:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433595 Vs 18:23:53 Integrated Voltage Measurement... 18:24:12 Voltage Offset Correction: v_off_ini = 0.000005823 V, v_off_fin = -0.000001731 V 18:24:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303683 Vs 18:24:15 Temperature Measurement, Probe Number = 0, T = 20.153000 C 18:24:16 Temperature Measurement, Probe Number = 1, T = 20.065000 C 18:24:17 Temperature Measurement, Probe Number = 2, T = 20.038000 C 18:24:17 Temperature Measurement, Probe Number = 3, T = 20.012000 C 18:24:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:24:18 Integrated Voltage Measurement... 18:24:37 Voltage Offset Correction: v_off_ini = 0.000001713 V, v_off_fin = 0.000006467 V 18:24:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439590 Vs 18:24:37 Integrated Voltage Measurement... 18:24:56 Voltage Offset Correction: v_off_ini = 0.000005701 V, v_off_fin = -0.000001278 V 18:24:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308941 Vs 18:24:59 Temperature Measurement, Probe Number = 0, T = 20.179000 C 18:25:00 Temperature Measurement, Probe Number = 1, T = 20.065000 C 18:25:00 Temperature Measurement, Probe Number = 2, T = 20.035000 C 18:25:01 Temperature Measurement, Probe Number = 3, T = 20.006000 C 18:25:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 18:25:01 Integrated Voltage Measurement... 18:25:20 Voltage Offset Correction: v_off_ini = 0.000002469 V, v_off_fin = 0.000006162 V 18:25:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434599 Vs 18:25:21 Integrated Voltage Measurement... 18:25:41 Voltage Offset Correction: v_off_ini = 0.000005480 V, v_off_fin = 0.000000045 V 18:25:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304508 Vs 18:25:44 Temperature Measurement, Probe Number = 0, T = 20.093000 C 18:25:45 Temperature Measurement, Probe Number = 1, T = 20.061000 C 18:25:45 Temperature Measurement, Probe Number = 2, T = 20.033000 C 18:25:46 Temperature Measurement, Probe Number = 3, T = 20.007000 C 18:25:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 18:25:46 Integrated Voltage Measurement... 18:26:05 Voltage Offset Correction: v_off_ini = 0.000001787 V, v_off_fin = 0.000006516 V 18:26:06 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175420018 Vs 18:26:06 Integrated Voltage Measurement... 18:26:25 Voltage Offset Correction: v_off_ini = 0.000005671 V, v_off_fin = -0.000001980 V 18:26:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300306 Vs 18:56:28 Temperature Measurement, Probe Number = 0, T = 20.071000 C 18:56:28 Temperature Measurement, Probe Number = 1, T = 20.056000 C 18:56:29 Temperature Measurement, Probe Number = 2, T = 20.025000 C 18:56:30 Temperature Measurement, Probe Number = 3, T = 20.006000 C 18:56:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:56:30 Integrated Voltage Measurement... 18:56:49 Voltage Offset Correction: v_off_ini = 0.000004064 V, v_off_fin = 0.000006582 V 18:56:49 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175526860 Vs 18:56:50 Integrated Voltage Measurement... 18:57:08 Voltage Offset Correction: v_off_ini = 0.000005634 V, v_off_fin = -0.000001736 V 18:57:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308959 Vs 18:57:11 Temperature Measurement, Probe Number = 0, T = 20.102000 C 18:57:12 Temperature Measurement, Probe Number = 1, T = 20.057000 C 18:57:13 Temperature Measurement, Probe Number = 2, T = 20.024000 C 18:57:13 Temperature Measurement, Probe Number = 3, T = 20.002000 C 18:57:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 18:57:13 Integrated Voltage Measurement... 18:57:33 Voltage Offset Correction: v_off_ini = 0.000002372 V, v_off_fin = 0.000007269 V 18:57:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175449214 Vs 18:57:33 Integrated Voltage Measurement... 18:57:52 Voltage Offset Correction: v_off_ini = 0.000005904 V, v_off_fin = -0.000000747 V 18:57:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313676 Vs 18:57:55 Temperature Measurement, Probe Number = 0, T = 20.142000 C 18:57:56 Temperature Measurement, Probe Number = 1, T = 20.058000 C 18:57:56 Temperature Measurement, Probe Number = 2, T = 20.027000 C 18:57:57 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:57:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:57:57 Integrated Voltage Measurement... 18:58:16 Voltage Offset Correction: v_off_ini = 0.000002406 V, v_off_fin = 0.000007190 V 18:58:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444349 Vs 18:58:17 Integrated Voltage Measurement... 18:58:36 Voltage Offset Correction: v_off_ini = 0.000006349 V, v_off_fin = -0.000001666 V 18:58:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306541 Vs 18:58:38 Temperature Measurement, Probe Number = 0, T = 20.136000 C 18:58:39 Temperature Measurement, Probe Number = 1, T = 20.059000 C 18:58:40 Temperature Measurement, Probe Number = 2, T = 20.029000 C 18:58:40 Temperature Measurement, Probe Number = 3, T = 20.002000 C 18:58:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:58:41 Integrated Voltage Measurement... 18:59:00 Voltage Offset Correction: v_off_ini = 0.000002524 V, v_off_fin = 0.000007366 V 18:59:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450149 Vs 18:59:00 Integrated Voltage Measurement... 18:59:19 Voltage Offset Correction: v_off_ini = 0.000006401 V, v_off_fin = -0.000001182 V 18:59:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309304 Vs 18:59:22 Temperature Measurement, Probe Number = 0, T = 20.180000 C 18:59:23 Temperature Measurement, Probe Number = 1, T = 20.059000 C 18:59:23 Temperature Measurement, Probe Number = 2, T = 20.029000 C 18:59:24 Temperature Measurement, Probe Number = 3, T = 20.005000 C 18:59:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 18:59:24 Integrated Voltage Measurement... 18:59:43 Voltage Offset Correction: v_off_ini = 0.000002466 V, v_off_fin = 0.000007793 V 18:59:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175457835 Vs 18:59:44 Integrated Voltage Measurement... 19:00:03 Voltage Offset Correction: v_off_ini = 0.000006695 V, v_off_fin = -0.000001032 V 19:00:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305258 Vs 19:00:06 Temperature Measurement, Probe Number = 0, T = 20.235000 C 19:00:06 Temperature Measurement, Probe Number = 1, T = 20.058000 C 19:00:07 Temperature Measurement, Probe Number = 2, T = 20.028000 C 19:00:08 Temperature Measurement, Probe Number = 3, T = 20.003000 C 19:00:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:00:08 Integrated Voltage Measurement... 19:00:27 Voltage Offset Correction: v_off_ini = 0.000002298 V, v_off_fin = 0.000006691 V 19:00:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451278 Vs 19:00:27 Integrated Voltage Measurement... 19:00:47 Voltage Offset Correction: v_off_ini = 0.000006303 V, v_off_fin = -0.000000615 V 19:00:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314683 Vs 19:00:50 Temperature Measurement, Probe Number = 0, T = 20.186000 C 19:00:51 Temperature Measurement, Probe Number = 1, T = 20.054000 C 19:00:51 Temperature Measurement, Probe Number = 2, T = 20.024000 C 19:00:52 Temperature Measurement, Probe Number = 3, T = 20.000000 C 19:00:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:00:52 Integrated Voltage Measurement... 19:01:11 Voltage Offset Correction: v_off_ini = 0.000001892 V, v_off_fin = 0.000007028 V 19:01:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175441676 Vs 19:01:11 Integrated Voltage Measurement... 19:01:31 Voltage Offset Correction: v_off_ini = 0.000006175 V, v_off_fin = -0.000001466 V 19:01:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315375 Vs 19:01:33 Temperature Measurement, Probe Number = 0, T = 20.127000 C 19:01:34 Temperature Measurement, Probe Number = 1, T = 20.054000 C 19:01:35 Temperature Measurement, Probe Number = 2, T = 20.025000 C 19:01:35 Temperature Measurement, Probe Number = 3, T = 20.001000 C 19:01:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:01:36 Integrated Voltage Measurement... 19:01:55 Voltage Offset Correction: v_off_ini = 0.000002032 V, v_off_fin = 0.000007491 V 19:01:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451032 Vs 19:01:55 Integrated Voltage Measurement... 19:02:15 Voltage Offset Correction: v_off_ini = 0.000006596 V, v_off_fin = -0.000000508 V 19:02:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313244 Vs 19:02:18 Temperature Measurement, Probe Number = 0, T = 20.089000 C 19:02:18 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:02:19 Temperature Measurement, Probe Number = 2, T = 20.026000 C 19:02:20 Temperature Measurement, Probe Number = 3, T = 20.002000 C 19:02:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:02:20 Integrated Voltage Measurement... 19:02:39 Voltage Offset Correction: v_off_ini = 0.000002278 V, v_off_fin = 0.000006844 V 19:02:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175446137 Vs 19:02:39 Integrated Voltage Measurement... 19:02:59 Voltage Offset Correction: v_off_ini = 0.000005986 V, v_off_fin = -0.000000632 V 19:02:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319984 Vs 19:03:02 Temperature Measurement, Probe Number = 0, T = 20.136000 C 19:03:02 Temperature Measurement, Probe Number = 1, T = 20.053000 C 19:03:03 Temperature Measurement, Probe Number = 2, T = 20.021000 C 19:03:04 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:03:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:03:04 Integrated Voltage Measurement... 19:03:23 Voltage Offset Correction: v_off_ini = 0.000001638 V, v_off_fin = 0.000006303 V 19:03:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175450871 Vs 19:03:23 Integrated Voltage Measurement... 19:03:42 Voltage Offset Correction: v_off_ini = 0.000005514 V, v_off_fin = -0.000001478 V 19:03:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314382 Vs 19:33:45 Temperature Measurement, Probe Number = 0, T = 20.232000 C 19:33:46 Temperature Measurement, Probe Number = 1, T = 20.051000 C 19:33:46 Temperature Measurement, Probe Number = 2, T = 20.020000 C 19:33:47 Temperature Measurement, Probe Number = 3, T = 19.996000 C 19:33:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:33:47 Integrated Voltage Measurement... 19:34:06 Voltage Offset Correction: v_off_ini = 0.000003675 V, v_off_fin = 0.000005950 V 19:34:06 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175531318 Vs 19:34:06 Integrated Voltage Measurement... 19:34:26 Voltage Offset Correction: v_off_ini = 0.000005335 V, v_off_fin = -0.000001264 V 19:34:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321623 Vs 19:34:28 Temperature Measurement, Probe Number = 0, T = 20.178000 C 19:34:29 Temperature Measurement, Probe Number = 1, T = 20.052000 C 19:34:30 Temperature Measurement, Probe Number = 2, T = 20.022000 C 19:34:30 Temperature Measurement, Probe Number = 3, T = 19.999000 C 19:34:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:34:31 Integrated Voltage Measurement... 19:34:50 Voltage Offset Correction: v_off_ini = 0.000001237 V, v_off_fin = 0.000006255 V 19:34:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446569 Vs 19:34:50 Integrated Voltage Measurement... 19:35:09 Voltage Offset Correction: v_off_ini = 0.000005537 V, v_off_fin = -0.000001718 V 19:35:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320081 Vs 19:35:12 Temperature Measurement, Probe Number = 0, T = 20.197000 C 19:35:13 Temperature Measurement, Probe Number = 1, T = 20.053000 C 19:35:13 Temperature Measurement, Probe Number = 2, T = 20.028000 C 19:35:14 Temperature Measurement, Probe Number = 3, T = 20.003000 C 19:35:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:35:14 Integrated Voltage Measurement... 19:35:33 Voltage Offset Correction: v_off_ini = 0.000002164 V, v_off_fin = 0.000006784 V 19:35:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175459254 Vs 19:35:33 Integrated Voltage Measurement... 19:35:53 Voltage Offset Correction: v_off_ini = 0.000005978 V, v_off_fin = -0.000001149 V 19:35:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320194 Vs 19:35:56 Temperature Measurement, Probe Number = 0, T = 20.178000 C 19:35:56 Temperature Measurement, Probe Number = 1, T = 20.052000 C 19:35:57 Temperature Measurement, Probe Number = 2, T = 20.028000 C 19:35:57 Temperature Measurement, Probe Number = 3, T = 20.003000 C 19:35:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:35:58 Integrated Voltage Measurement... 19:36:17 Voltage Offset Correction: v_off_ini = 0.000002580 V, v_off_fin = 0.000006499 V 19:36:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175455477 Vs 19:36:17 Integrated Voltage Measurement... 19:36:36 Voltage Offset Correction: v_off_ini = 0.000006098 V, v_off_fin = -0.000002217 V 19:36:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312270 Vs 19:36:39 Temperature Measurement, Probe Number = 0, T = 20.232000 C 19:36:40 Temperature Measurement, Probe Number = 1, T = 20.054000 C 19:36:40 Temperature Measurement, Probe Number = 2, T = 20.027000 C 19:36:41 Temperature Measurement, Probe Number = 3, T = 20.004000 C 19:36:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:36:41 Integrated Voltage Measurement... 19:37:01 Voltage Offset Correction: v_off_ini = 0.000002501 V, v_off_fin = 0.000007013 V 19:37:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175462078 Vs 19:37:01 Integrated Voltage Measurement... 19:37:20 Voltage Offset Correction: v_off_ini = 0.000006257 V, v_off_fin = -0.000001263 V 19:37:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321848 Vs 19:37:23 Temperature Measurement, Probe Number = 0, T = 20.290000 C 19:37:24 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:37:24 Temperature Measurement, Probe Number = 2, T = 20.028000 C 19:37:25 Temperature Measurement, Probe Number = 3, T = 20.003000 C 19:37:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:37:25 Integrated Voltage Measurement... 19:37:44 Voltage Offset Correction: v_off_ini = 0.000001932 V, v_off_fin = 0.000006633 V 19:37:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175453553 Vs 19:37:45 Integrated Voltage Measurement... 19:38:04 Voltage Offset Correction: v_off_ini = 0.000005569 V, v_off_fin = -0.000001728 V 19:38:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322960 Vs 19:38:07 Temperature Measurement, Probe Number = 0, T = 20.284000 C 19:38:07 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:38:08 Temperature Measurement, Probe Number = 2, T = 20.029000 C 19:38:09 Temperature Measurement, Probe Number = 3, T = 20.003000 C 19:38:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:38:09 Integrated Voltage Measurement... 19:38:28 Voltage Offset Correction: v_off_ini = 0.000002351 V, v_off_fin = 0.000006809 V 19:38:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175450454 Vs 19:38:28 Integrated Voltage Measurement... 19:38:49 Voltage Offset Correction: v_off_ini = 0.000006507 V, v_off_fin = -0.000000285 V 19:38:49 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175311028 Vs 19:38:52 Temperature Measurement, Probe Number = 0, T = 20.313000 C 19:38:52 Temperature Measurement, Probe Number = 1, T = 20.056000 C 19:38:53 Temperature Measurement, Probe Number = 2, T = 20.029000 C 19:38:54 Temperature Measurement, Probe Number = 3, T = 20.005000 C 19:38:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:38:54 Integrated Voltage Measurement... 19:39:13 Voltage Offset Correction: v_off_ini = 0.000002958 V, v_off_fin = 0.000006795 V 19:39:13 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175438981 Vs 19:39:13 Integrated Voltage Measurement... 19:39:33 Voltage Offset Correction: v_off_ini = 0.000005515 V, v_off_fin = -0.000002198 V 19:39:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319980 Vs 19:39:35 Temperature Measurement, Probe Number = 0, T = 20.287000 C 19:39:36 Temperature Measurement, Probe Number = 1, T = 20.055000 C 19:39:37 Temperature Measurement, Probe Number = 2, T = 20.030000 C 19:39:37 Temperature Measurement, Probe Number = 3, T = 20.005000 C 19:39:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 19:39:38 Integrated Voltage Measurement... 19:39:57 Voltage Offset Correction: v_off_ini = 0.000001200 V, v_off_fin = 0.000006491 V 19:39:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175448092 Vs 19:39:57 Integrated Voltage Measurement... 19:40:16 Voltage Offset Correction: v_off_ini = 0.000005827 V, v_off_fin = -0.000002861 V 19:40:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323852 Vs 19:40:19 Temperature Measurement, Probe Number = 0, T = 20.315000 C 19:40:20 Temperature Measurement, Probe Number = 1, T = 20.058000 C 19:40:21 Temperature Measurement, Probe Number = 2, T = 20.029000 C 19:40:21 Temperature Measurement, Probe Number = 3, T = 20.006000 C 19:40:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 19:40:22 Integrated Voltage Measurement... 19:40:41 Voltage Offset Correction: v_off_ini = 0.000001948 V, v_off_fin = 0.000006364 V 19:40:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444836 Vs 19:40:41 Integrated Voltage Measurement... 19:41:00 Voltage Offset Correction: v_off_ini = 0.000005340 V, v_off_fin = -0.000002557 V 19:41:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326613 Vs 20:11:03 Temperature Measurement, Probe Number = 0, T = 20.221000 C 20:11:04 Temperature Measurement, Probe Number = 1, T = 20.050000 C 20:11:04 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:11:05 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:11:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:11:05 Integrated Voltage Measurement... 20:11:24 Voltage Offset Correction: v_off_ini = 0.000004597 V, v_off_fin = 0.000006617 V 20:11:24 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175544064 Vs 20:11:24 Integrated Voltage Measurement... 20:11:43 Voltage Offset Correction: v_off_ini = 0.000005660 V, v_off_fin = -0.000002096 V 20:11:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317378 Vs 20:11:46 Temperature Measurement, Probe Number = 0, T = 20.197000 C 20:11:47 Temperature Measurement, Probe Number = 1, T = 20.050000 C 20:11:48 Temperature Measurement, Probe Number = 2, T = 20.021000 C 20:11:48 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:11:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:11:48 Integrated Voltage Measurement... 20:12:07 Voltage Offset Correction: v_off_ini = 0.000001295 V, v_off_fin = 0.000006697 V 20:12:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447393 Vs 20:12:08 Integrated Voltage Measurement... 20:12:27 Voltage Offset Correction: v_off_ini = 0.000006057 V, v_off_fin = -0.000001577 V 20:12:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318941 Vs 20:12:30 Temperature Measurement, Probe Number = 0, T = 20.194000 C 20:12:31 Temperature Measurement, Probe Number = 1, T = 20.050000 C 20:12:32 Temperature Measurement, Probe Number = 2, T = 20.018000 C 20:12:32 Temperature Measurement, Probe Number = 3, T = 19.998000 C 20:12:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:12:32 Integrated Voltage Measurement... 20:12:51 Voltage Offset Correction: v_off_ini = 0.000001930 V, v_off_fin = 0.000007176 V 20:12:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175451083 Vs 20:12:52 Integrated Voltage Measurement... 20:13:11 Voltage Offset Correction: v_off_ini = 0.000005985 V, v_off_fin = -0.000001472 V 20:13:11 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309643 Vs 20:13:13 Temperature Measurement, Probe Number = 0, T = 20.152000 C 20:13:14 Temperature Measurement, Probe Number = 1, T = 20.048000 C 20:13:15 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:13:15 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:13:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:13:16 Integrated Voltage Measurement... 20:13:35 Voltage Offset Correction: v_off_ini = 0.000002399 V, v_off_fin = 0.000007328 V 20:13:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175461508 Vs 20:13:35 Integrated Voltage Measurement... 20:13:54 Voltage Offset Correction: v_off_ini = 0.000005976 V, v_off_fin = -0.000001413 V 20:13:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310645 Vs 20:13:57 Temperature Measurement, Probe Number = 0, T = 20.107000 C 20:13:58 Temperature Measurement, Probe Number = 1, T = 20.049000 C 20:13:58 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:13:59 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:13:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 20:13:59 Integrated Voltage Measurement... 20:14:19 Voltage Offset Correction: v_off_ini = 0.000001761 V, v_off_fin = 0.000006876 V 20:14:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451132 Vs 20:14:19 Integrated Voltage Measurement... 20:14:38 Voltage Offset Correction: v_off_ini = 0.000005706 V, v_off_fin = -0.000001851 V 20:14:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319407 Vs 20:14:41 Temperature Measurement, Probe Number = 0, T = 20.226000 C 20:14:42 Temperature Measurement, Probe Number = 1, T = 20.050000 C 20:14:42 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:14:43 Temperature Measurement, Probe Number = 3, T = 19.998000 C 20:14:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:14:43 Integrated Voltage Measurement... 20:15:02 Voltage Offset Correction: v_off_ini = 0.000001403 V, v_off_fin = 0.000006696 V 20:15:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451144 Vs 20:15:03 Integrated Voltage Measurement... 20:15:22 Voltage Offset Correction: v_off_ini = 0.000005942 V, v_off_fin = -0.000001273 V 20:15:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307723 Vs 20:15:25 Temperature Measurement, Probe Number = 0, T = 20.241000 C 20:15:25 Temperature Measurement, Probe Number = 1, T = 20.049000 C 20:15:26 Temperature Measurement, Probe Number = 2, T = 20.020000 C 20:15:27 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:15:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:15:27 Integrated Voltage Measurement... 20:15:46 Voltage Offset Correction: v_off_ini = 0.000002429 V, v_off_fin = 0.000007230 V 20:15:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175455841 Vs 20:15:46 Integrated Voltage Measurement... 20:16:06 Voltage Offset Correction: v_off_ini = 0.000006676 V, v_off_fin = -0.000000843 V 20:16:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308999 Vs 20:16:08 Temperature Measurement, Probe Number = 0, T = 20.245000 C 20:16:09 Temperature Measurement, Probe Number = 1, T = 20.048000 C 20:16:10 Temperature Measurement, Probe Number = 2, T = 20.020000 C 20:16:10 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:16:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:16:11 Integrated Voltage Measurement... 20:16:30 Voltage Offset Correction: v_off_ini = 0.000002246 V, v_off_fin = 0.000006651 V 20:16:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451035 Vs 20:16:30 Integrated Voltage Measurement... 20:16:50 Voltage Offset Correction: v_off_ini = 0.000006197 V, v_off_fin = -0.000001055 V 20:16:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315435 Vs 20:16:52 Temperature Measurement, Probe Number = 0, T = 20.275000 C 20:16:53 Temperature Measurement, Probe Number = 1, T = 20.049000 C 20:16:54 Temperature Measurement, Probe Number = 2, T = 20.019000 C 20:16:54 Temperature Measurement, Probe Number = 3, T = 19.998000 C 20:16:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:16:54 Integrated Voltage Measurement... 20:17:14 Voltage Offset Correction: v_off_ini = 0.000002412 V, v_off_fin = 0.000007077 V 20:17:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175446876 Vs 20:17:14 Integrated Voltage Measurement... 20:17:34 Voltage Offset Correction: v_off_ini = 0.000006274 V, v_off_fin = -0.000001418 V 20:17:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314974 Vs 20:17:36 Temperature Measurement, Probe Number = 0, T = 20.201000 C 20:17:37 Temperature Measurement, Probe Number = 1, T = 20.050000 C 20:17:38 Temperature Measurement, Probe Number = 2, T = 20.020000 C 20:17:38 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:17:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:17:39 Integrated Voltage Measurement... 20:17:58 Voltage Offset Correction: v_off_ini = 0.000002338 V, v_off_fin = 0.000007603 V 20:17:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175456719 Vs 20:17:58 Integrated Voltage Measurement... 20:18:17 Voltage Offset Correction: v_off_ini = 0.000006790 V, v_off_fin = -0.000001078 V 20:18:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304910 Vs 20:48:20 Temperature Measurement, Probe Number = 0, T = 20.108000 C 20:48:21 Temperature Measurement, Probe Number = 1, T = 20.044000 C 20:48:21 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:48:22 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:48:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:48:22 Integrated Voltage Measurement... 20:48:41 Voltage Offset Correction: v_off_ini = 0.000004560 V, v_off_fin = 0.000007167 V 20:48:42 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175551355 Vs 20:48:42 Integrated Voltage Measurement... 20:49:01 Voltage Offset Correction: v_off_ini = 0.000006302 V, v_off_fin = -0.000001285 V 20:49:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304411 Vs 20:49:04 Temperature Measurement, Probe Number = 0, T = 20.142000 C 20:49:04 Temperature Measurement, Probe Number = 1, T = 20.046000 C 20:49:05 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:49:06 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:49:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:49:06 Integrated Voltage Measurement... 20:49:25 Voltage Offset Correction: v_off_ini = 0.000002716 V, v_off_fin = 0.000006740 V 20:49:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175458454 Vs 20:49:25 Integrated Voltage Measurement... 20:49:45 Voltage Offset Correction: v_off_ini = 0.000006698 V, v_off_fin = -0.000001326 V 20:49:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314559 Vs 20:49:47 Temperature Measurement, Probe Number = 0, T = 20.112000 C 20:49:48 Temperature Measurement, Probe Number = 1, T = 20.046000 C 20:49:49 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:49:49 Temperature Measurement, Probe Number = 3, T = 19.998000 C 20:49:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:49:50 Integrated Voltage Measurement... 20:50:09 Voltage Offset Correction: v_off_ini = 0.000002226 V, v_off_fin = 0.000007119 V 20:50:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175452928 Vs 20:50:09 Integrated Voltage Measurement... 20:50:28 Voltage Offset Correction: v_off_ini = 0.000006018 V, v_off_fin = -0.000001984 V 20:50:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313847 Vs 20:50:31 Temperature Measurement, Probe Number = 0, T = 20.109000 C 20:50:32 Temperature Measurement, Probe Number = 1, T = 20.045000 C 20:50:32 Temperature Measurement, Probe Number = 2, T = 20.014000 C 20:50:33 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:50:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:50:33 Integrated Voltage Measurement... 20:50:53 Voltage Offset Correction: v_off_ini = 0.000002854 V, v_off_fin = 0.000007395 V 20:50:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175460166 Vs 20:50:53 Integrated Voltage Measurement... 20:51:12 Voltage Offset Correction: v_off_ini = 0.000006533 V, v_off_fin = -0.000000769 V 20:51:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306842 Vs 20:51:15 Temperature Measurement, Probe Number = 0, T = 20.048000 C 20:51:16 Temperature Measurement, Probe Number = 1, T = 20.043000 C 20:51:16 Temperature Measurement, Probe Number = 2, T = 20.015000 C 20:51:17 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:51:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:51:17 Integrated Voltage Measurement... 20:51:36 Voltage Offset Correction: v_off_ini = 0.000002285 V, v_off_fin = 0.000007084 V 20:51:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175451848 Vs 20:51:36 Integrated Voltage Measurement... 20:51:55 Voltage Offset Correction: v_off_ini = 0.000005846 V, v_off_fin = -0.000001415 V 20:51:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319853 Vs 20:51:58 Temperature Measurement, Probe Number = 0, T = 20.090000 C 20:51:59 Temperature Measurement, Probe Number = 1, T = 20.043000 C 20:51:59 Temperature Measurement, Probe Number = 2, T = 20.018000 C 20:52:00 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:52:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:52:00 Integrated Voltage Measurement... 20:52:19 Voltage Offset Correction: v_off_ini = 0.000002107 V, v_off_fin = 0.000006873 V 20:52:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450521 Vs 20:52:19 Integrated Voltage Measurement... 20:52:39 Voltage Offset Correction: v_off_ini = 0.000006312 V, v_off_fin = -0.000001138 V 20:52:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318312 Vs 20:52:42 Temperature Measurement, Probe Number = 0, T = 20.039000 C 20:52:42 Temperature Measurement, Probe Number = 1, T = 20.042000 C 20:52:43 Temperature Measurement, Probe Number = 2, T = 20.017000 C 20:52:44 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:52:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:52:44 Integrated Voltage Measurement... 20:53:03 Voltage Offset Correction: v_off_ini = 0.000001765 V, v_off_fin = 0.000006426 V 20:53:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441588 Vs 20:53:03 Integrated Voltage Measurement... 20:53:22 Voltage Offset Correction: v_off_ini = 0.000005717 V, v_off_fin = -0.000002401 V 20:53:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317392 Vs 20:53:25 Temperature Measurement, Probe Number = 0, T = 19.999000 C 20:53:26 Temperature Measurement, Probe Number = 1, T = 20.042000 C 20:53:26 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:53:27 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:53:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:53:27 Integrated Voltage Measurement... 20:53:46 Voltage Offset Correction: v_off_ini = 0.000001645 V, v_off_fin = 0.000006724 V 20:53:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175453667 Vs 20:53:46 Integrated Voltage Measurement... 20:54:05 Voltage Offset Correction: v_off_ini = 0.000005942 V, v_off_fin = -0.000001134 V 20:54:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319401 Vs 20:54:08 Temperature Measurement, Probe Number = 0, T = 19.978000 C 20:54:09 Temperature Measurement, Probe Number = 1, T = 20.043000 C 20:54:10 Temperature Measurement, Probe Number = 2, T = 20.014000 C 20:54:10 Temperature Measurement, Probe Number = 3, T = 19.993000 C 20:54:10 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 20:54:10 Integrated Voltage Measurement... 20:54:29 Voltage Offset Correction: v_off_ini = 0.000002314 V, v_off_fin = 0.000006700 V 20:54:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450969 Vs 20:54:30 Integrated Voltage Measurement... 20:54:49 Voltage Offset Correction: v_off_ini = 0.000005667 V, v_off_fin = -0.000001318 V 20:54:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325616 Vs 20:54:52 Temperature Measurement, Probe Number = 0, T = 19.984000 C 20:54:52 Temperature Measurement, Probe Number = 1, T = 20.042000 C 20:54:53 Temperature Measurement, Probe Number = 2, T = 20.014000 C 20:54:54 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:54:54 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:54:54 Integrated Voltage Measurement... 20:55:13 Voltage Offset Correction: v_off_ini = 0.000002115 V, v_off_fin = 0.000006802 V 20:55:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175450183 Vs 20:55:13 Integrated Voltage Measurement... 20:55:32 Voltage Offset Correction: v_off_ini = 0.000005671 V, v_off_fin = -0.000002689 V 20:55:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313238 Vs 21:25:35 Temperature Measurement, Probe Number = 0, T = 20.036000 C 21:25:36 Temperature Measurement, Probe Number = 1, T = 20.036000 C 21:25:37 Temperature Measurement, Probe Number = 2, T = 20.004000 C 21:25:37 Temperature Measurement, Probe Number = 3, T = 19.991000 C 21:25:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 21:25:38 Integrated Voltage Measurement... 21:25:57 Voltage Offset Correction: v_off_ini = 0.000004929 V, v_off_fin = 0.000007036 V 21:25:57 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175547167 Vs 21:25:57 Integrated Voltage Measurement... 21:26:16 Voltage Offset Correction: v_off_ini = 0.000005912 V, v_off_fin = -0.000001730 V 21:26:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310211 Vs 21:26:19 Temperature Measurement, Probe Number = 0, T = 20.049000 C 21:26:20 Temperature Measurement, Probe Number = 1, T = 20.036000 C 21:26:20 Temperature Measurement, Probe Number = 2, T = 20.007000 C 21:26:21 Temperature Measurement, Probe Number = 3, T = 19.992000 C 21:26:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:26:21 Integrated Voltage Measurement... 21:26:41 Voltage Offset Correction: v_off_ini = 0.000002256 V, v_off_fin = 0.000006954 V 21:26:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448647 Vs 21:26:41 Integrated Voltage Measurement... 21:27:00 Voltage Offset Correction: v_off_ini = 0.000006051 V, v_off_fin = -0.000001842 V 21:27:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311001 Vs 21:27:03 Temperature Measurement, Probe Number = 0, T = 20.057000 C 21:27:03 Temperature Measurement, Probe Number = 1, T = 20.035000 C 21:27:04 Temperature Measurement, Probe Number = 2, T = 20.005000 C 21:27:05 Temperature Measurement, Probe Number = 3, T = 19.989000 C 21:27:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 21:27:05 Integrated Voltage Measurement... 21:27:24 Voltage Offset Correction: v_off_ini = 0.000001875 V, v_off_fin = 0.000006714 V 21:27:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175452134 Vs 21:27:24 Integrated Voltage Measurement... 21:27:44 Voltage Offset Correction: v_off_ini = 0.000005793 V, v_off_fin = -0.000002862 V 21:27:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313067 Vs 21:27:46 Temperature Measurement, Probe Number = 0, T = 19.991000 C 21:27:47 Temperature Measurement, Probe Number = 1, T = 20.035000 C 21:27:48 Temperature Measurement, Probe Number = 2, T = 20.006000 C 21:27:48 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:27:48 Magnet Test Parameter Measurements P0 = Room, Value = 19.99 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:27:49 Integrated Voltage Measurement... 21:28:08 Voltage Offset Correction: v_off_ini = 0.000002262 V, v_off_fin = 0.000006784 V 21:28:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453373 Vs 21:28:08 Integrated Voltage Measurement... 21:28:27 Voltage Offset Correction: v_off_ini = 0.000006082 V, v_off_fin = -0.000001506 V 21:28:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313327 Vs 21:28:30 Temperature Measurement, Probe Number = 0, T = 19.948000 C 21:28:31 Temperature Measurement, Probe Number = 1, T = 20.036000 C 21:28:31 Temperature Measurement, Probe Number = 2, T = 20.010000 C 21:28:32 Temperature Measurement, Probe Number = 3, T = 19.994000 C 21:28:32 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:28:32 Integrated Voltage Measurement... 21:28:51 Voltage Offset Correction: v_off_ini = 0.000001357 V, v_off_fin = 0.000007111 V 21:28:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453938 Vs 21:28:52 Integrated Voltage Measurement... 21:29:11 Voltage Offset Correction: v_off_ini = 0.000006647 V, v_off_fin = -0.000001431 V 21:29:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316315 Vs 21:29:14 Temperature Measurement, Probe Number = 0, T = 19.950000 C 21:29:15 Temperature Measurement, Probe Number = 1, T = 20.037000 C 21:29:15 Temperature Measurement, Probe Number = 2, T = 20.009000 C 21:29:16 Temperature Measurement, Probe Number = 3, T = 19.992000 C 21:29:16 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:29:16 Integrated Voltage Measurement... 21:29:35 Voltage Offset Correction: v_off_ini = 0.000002467 V, v_off_fin = 0.000006875 V 21:29:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175455963 Vs 21:29:36 Integrated Voltage Measurement... 21:29:55 Voltage Offset Correction: v_off_ini = 0.000006285 V, v_off_fin = -0.000001545 V 21:29:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311190 Vs 21:29:57 Temperature Measurement, Probe Number = 0, T = 19.917000 C 21:29:58 Temperature Measurement, Probe Number = 1, T = 20.037000 C 21:29:59 Temperature Measurement, Probe Number = 2, T = 20.006000 C 21:29:59 Temperature Measurement, Probe Number = 3, T = 19.987000 C 21:29:59 Magnet Test Parameter Measurements P0 = Room, Value = 19.92 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:29:59 Integrated Voltage Measurement... 21:30:19 Voltage Offset Correction: v_off_ini = 0.000002298 V, v_off_fin = 0.000006360 V 21:30:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175452252 Vs 21:30:19 Integrated Voltage Measurement... 21:30:38 Voltage Offset Correction: v_off_ini = 0.000005680 V, v_off_fin = -0.000001905 V 21:30:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315921 Vs 21:30:41 Temperature Measurement, Probe Number = 0, T = 20.001000 C 21:30:41 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:30:42 Temperature Measurement, Probe Number = 2, T = 20.004000 C 21:30:43 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:30:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 21:30:43 Integrated Voltage Measurement... 21:31:02 Voltage Offset Correction: v_off_ini = 0.000002081 V, v_off_fin = 0.000007161 V 21:31:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175456712 Vs 21:31:03 Integrated Voltage Measurement... 21:31:22 Voltage Offset Correction: v_off_ini = 0.000006789 V, v_off_fin = -0.000001757 V 21:31:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312183 Vs 21:31:25 Temperature Measurement, Probe Number = 0, T = 20.091000 C 21:31:25 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:31:26 Temperature Measurement, Probe Number = 2, T = 20.010000 C 21:31:27 Temperature Measurement, Probe Number = 3, T = 19.991000 C 21:31:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:31:27 Integrated Voltage Measurement... 21:31:46 Voltage Offset Correction: v_off_ini = 0.000001804 V, v_off_fin = 0.000006923 V 21:31:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175456699 Vs 21:31:46 Integrated Voltage Measurement... 21:32:05 Voltage Offset Correction: v_off_ini = 0.000006392 V, v_off_fin = -0.000001908 V 21:32:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311277 Vs 21:32:08 Temperature Measurement, Probe Number = 0, T = 20.130000 C 21:32:08 Temperature Measurement, Probe Number = 1, T = 20.037000 C 21:32:09 Temperature Measurement, Probe Number = 2, T = 20.006000 C 21:32:10 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:32:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:32:10 Integrated Voltage Measurement... 21:32:29 Voltage Offset Correction: v_off_ini = 0.000002533 V, v_off_fin = 0.000006781 V 21:32:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175454361 Vs 21:32:29 Integrated Voltage Measurement... 21:32:49 Voltage Offset Correction: v_off_ini = 0.000005964 V, v_off_fin = -0.000001684 V 21:32:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323057 Vs 22:02:51 Temperature Measurement, Probe Number = 0, T = 20.125000 C 22:02:52 Temperature Measurement, Probe Number = 1, T = 20.033000 C 22:02:53 Temperature Measurement, Probe Number = 2, T = 20.002000 C 22:02:53 Temperature Measurement, Probe Number = 3, T = 19.987000 C 22:02:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:02:54 Integrated Voltage Measurement... 22:03:13 Voltage Offset Correction: v_off_ini = 0.000004996 V, v_off_fin = 0.000007015 V 22:03:13 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175544444 Vs 22:03:13 Integrated Voltage Measurement... 22:03:32 Voltage Offset Correction: v_off_ini = 0.000006435 V, v_off_fin = -0.000001149 V 22:03:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307640 Vs 22:03:35 Temperature Measurement, Probe Number = 0, T = 20.152000 C 22:03:36 Temperature Measurement, Probe Number = 1, T = 20.034000 C 22:03:36 Temperature Measurement, Probe Number = 2, T = 20.006000 C 22:03:37 Temperature Measurement, Probe Number = 3, T = 19.990000 C 22:03:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:03:37 Integrated Voltage Measurement... 22:03:57 Voltage Offset Correction: v_off_ini = 0.000001699 V, v_off_fin = 0.000006727 V 22:03:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450982 Vs 22:03:57 Integrated Voltage Measurement... 22:04:16 Voltage Offset Correction: v_off_ini = 0.000005787 V, v_off_fin = -0.000001653 V 22:04:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310582 Vs 22:04:19 Temperature Measurement, Probe Number = 0, T = 20.229000 C 22:04:20 Temperature Measurement, Probe Number = 1, T = 20.034000 C 22:04:20 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:04:21 Temperature Measurement, Probe Number = 3, T = 19.989000 C 22:04:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:04:21 Integrated Voltage Measurement... 22:04:40 Voltage Offset Correction: v_off_ini = 0.000002186 V, v_off_fin = 0.000007289 V 22:04:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450355 Vs 22:04:40 Integrated Voltage Measurement... 22:04:59 Voltage Offset Correction: v_off_ini = 0.000006298 V, v_off_fin = -0.000000994 V 22:04:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308239 Vs 22:05:02 Temperature Measurement, Probe Number = 0, T = 20.233000 C 22:05:03 Temperature Measurement, Probe Number = 1, T = 20.039000 C 22:05:03 Temperature Measurement, Probe Number = 2, T = 20.008000 C 22:05:04 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:05:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:05:04 Integrated Voltage Measurement... 22:05:23 Voltage Offset Correction: v_off_ini = 0.000002265 V, v_off_fin = 0.000007437 V 22:05:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447755 Vs 22:05:24 Integrated Voltage Measurement... 22:05:43 Voltage Offset Correction: v_off_ini = 0.000006071 V, v_off_fin = -0.000001595 V 22:05:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311502 Vs 22:05:46 Temperature Measurement, Probe Number = 0, T = 20.248000 C 22:05:46 Temperature Measurement, Probe Number = 1, T = 20.039000 C 22:05:47 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:05:48 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:05:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:05:48 Integrated Voltage Measurement... 22:06:07 Voltage Offset Correction: v_off_ini = 0.000001692 V, v_off_fin = 0.000006922 V 22:06:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175449546 Vs 22:06:07 Integrated Voltage Measurement... 22:06:27 Voltage Offset Correction: v_off_ini = 0.000006065 V, v_off_fin = -0.000000372 V 22:06:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319109 Vs 22:06:29 Temperature Measurement, Probe Number = 0, T = 20.246000 C 22:06:30 Temperature Measurement, Probe Number = 1, T = 20.038000 C 22:06:31 Temperature Measurement, Probe Number = 2, T = 20.008000 C 22:06:31 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:06:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:06:32 Integrated Voltage Measurement... 22:06:51 Voltage Offset Correction: v_off_ini = 0.000002540 V, v_off_fin = 0.000006504 V 22:06:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175446474 Vs 22:06:51 Integrated Voltage Measurement... 22:07:10 Voltage Offset Correction: v_off_ini = 0.000005656 V, v_off_fin = -0.000001764 V 22:07:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308353 Vs 22:07:13 Temperature Measurement, Probe Number = 0, T = 20.270000 C 22:07:14 Temperature Measurement, Probe Number = 1, T = 20.039000 C 22:07:14 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:07:15 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:07:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:07:15 Integrated Voltage Measurement... 22:07:34 Voltage Offset Correction: v_off_ini = 0.000001488 V, v_off_fin = 0.000006858 V 22:07:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444539 Vs 22:07:34 Integrated Voltage Measurement... 22:07:54 Voltage Offset Correction: v_off_ini = 0.000005961 V, v_off_fin = -0.000001419 V 22:07:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313663 Vs 22:07:57 Temperature Measurement, Probe Number = 0, T = 20.300000 C 22:07:57 Temperature Measurement, Probe Number = 1, T = 20.041000 C 22:07:58 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:07:59 Temperature Measurement, Probe Number = 3, T = 19.993000 C 22:07:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:07:59 Integrated Voltage Measurement... 22:08:18 Voltage Offset Correction: v_off_ini = 0.000001727 V, v_off_fin = 0.000006445 V 22:08:18 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175442652 Vs 22:08:18 Integrated Voltage Measurement... 22:08:38 Voltage Offset Correction: v_off_ini = 0.000005687 V, v_off_fin = -0.000001802 V 22:08:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324818 Vs 22:08:41 Temperature Measurement, Probe Number = 0, T = 20.310000 C 22:08:41 Temperature Measurement, Probe Number = 1, T = 20.038000 C 22:08:42 Temperature Measurement, Probe Number = 2, T = 20.009000 C 22:08:43 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:08:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:08:43 Integrated Voltage Measurement... 22:09:02 Voltage Offset Correction: v_off_ini = 0.000001779 V, v_off_fin = 0.000006538 V 22:09:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175452267 Vs 22:09:02 Integrated Voltage Measurement... 22:09:22 Voltage Offset Correction: v_off_ini = 0.000005747 V, v_off_fin = -0.000001532 V 22:09:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323830 Vs 22:09:25 Temperature Measurement, Probe Number = 0, T = 20.248000 C 22:09:25 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:09:26 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:09:27 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:09:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:09:27 Integrated Voltage Measurement... 22:09:46 Voltage Offset Correction: v_off_ini = 0.000001285 V, v_off_fin = 0.000006262 V 22:09:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445492 Vs 22:09:47 Integrated Voltage Measurement... 22:10:06 Voltage Offset Correction: v_off_ini = 0.000005289 V, v_off_fin = -0.000001598 V 22:10:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324017 Vs 22:40:09 Temperature Measurement, Probe Number = 0, T = 20.177000 C 22:40:10 Temperature Measurement, Probe Number = 1, T = 20.034000 C 22:40:11 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:40:11 Temperature Measurement, Probe Number = 3, T = 19.988000 C 22:40:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:40:11 Integrated Voltage Measurement... 22:40:30 Voltage Offset Correction: v_off_ini = 0.000004877 V, v_off_fin = 0.000007077 V 22:40:31 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175541918 Vs 22:40:31 Integrated Voltage Measurement... 22:40:50 Voltage Offset Correction: v_off_ini = 0.000005825 V, v_off_fin = -0.000000975 V 22:40:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304198 Vs 22:40:53 Temperature Measurement, Probe Number = 0, T = 20.178000 C 22:40:53 Temperature Measurement, Probe Number = 1, T = 20.037000 C 22:40:54 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:40:55 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:40:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:40:55 Integrated Voltage Measurement... 22:41:14 Voltage Offset Correction: v_off_ini = 0.000002194 V, v_off_fin = 0.000006133 V 22:41:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446974 Vs 22:41:14 Integrated Voltage Measurement... 22:41:34 Voltage Offset Correction: v_off_ini = 0.000005325 V, v_off_fin = -0.000001719 V 22:41:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321636 Vs 22:41:37 Temperature Measurement, Probe Number = 0, T = 20.160000 C 22:41:37 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:41:38 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:41:39 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:41:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:41:39 Integrated Voltage Measurement... 22:41:59 Voltage Offset Correction: v_off_ini = 0.000001645 V, v_off_fin = 0.000006178 V 22:41:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443860 Vs 22:41:59 Integrated Voltage Measurement... 22:42:18 Voltage Offset Correction: v_off_ini = 0.000005138 V, v_off_fin = -0.000002139 V 22:42:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315179 Vs 22:42:21 Temperature Measurement, Probe Number = 0, T = 20.174000 C 22:42:22 Temperature Measurement, Probe Number = 1, T = 20.037000 C 22:42:22 Temperature Measurement, Probe Number = 2, T = 20.008000 C 22:42:23 Temperature Measurement, Probe Number = 3, T = 19.990000 C 22:42:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:42:23 Integrated Voltage Measurement... 22:42:42 Voltage Offset Correction: v_off_ini = 0.000001711 V, v_off_fin = 0.000006545 V 22:42:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436434 Vs 22:42:43 Integrated Voltage Measurement... 22:43:02 Voltage Offset Correction: v_off_ini = 0.000005838 V, v_off_fin = -0.000001697 V 22:43:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301341 Vs 22:43:04 Temperature Measurement, Probe Number = 0, T = 20.183000 C 22:43:05 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:43:06 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:43:06 Temperature Measurement, Probe Number = 3, T = 19.988000 C 22:43:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:43:07 Integrated Voltage Measurement... 22:43:26 Voltage Offset Correction: v_off_ini = 0.000002135 V, v_off_fin = 0.000007069 V 22:43:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443180 Vs 22:43:26 Integrated Voltage Measurement... 22:43:45 Voltage Offset Correction: v_off_ini = 0.000006286 V, v_off_fin = -0.000001648 V 22:43:46 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175295776 Vs 22:43:48 Temperature Measurement, Probe Number = 0, T = 20.182000 C 22:43:49 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:43:50 Temperature Measurement, Probe Number = 2, T = 20.002000 C 22:43:50 Temperature Measurement, Probe Number = 3, T = 19.987000 C 22:43:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:43:50 Integrated Voltage Measurement... 22:44:10 Voltage Offset Correction: v_off_ini = 0.000001704 V, v_off_fin = 0.000006738 V 22:44:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435923 Vs 22:44:10 Integrated Voltage Measurement... 22:44:29 Voltage Offset Correction: v_off_ini = 0.000005934 V, v_off_fin = -0.000001813 V 22:44:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296705 Vs 22:44:32 Temperature Measurement, Probe Number = 0, T = 20.215000 C 22:44:33 Temperature Measurement, Probe Number = 1, T = 20.038000 C 22:44:33 Temperature Measurement, Probe Number = 2, T = 20.002000 C 22:44:34 Temperature Measurement, Probe Number = 3, T = 19.989000 C 22:44:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:44:34 Integrated Voltage Measurement... 22:44:53 Voltage Offset Correction: v_off_ini = 0.000002460 V, v_off_fin = 0.000006896 V 22:44:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435091 Vs 22:44:53 Integrated Voltage Measurement... 22:45:12 Voltage Offset Correction: v_off_ini = 0.000005938 V, v_off_fin = -0.000001839 V 22:45:13 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175296005 Vs 22:45:15 Temperature Measurement, Probe Number = 0, T = 20.203000 C 22:45:16 Temperature Measurement, Probe Number = 1, T = 20.034000 C 22:45:17 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:45:17 Temperature Measurement, Probe Number = 3, T = 19.989000 C 22:45:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:45:17 Integrated Voltage Measurement... 22:45:37 Voltage Offset Correction: v_off_ini = 0.000001785 V, v_off_fin = 0.000006630 V 22:45:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435755 Vs 22:45:37 Integrated Voltage Measurement... 22:45:56 Voltage Offset Correction: v_off_ini = 0.000005626 V, v_off_fin = -0.000001205 V 22:45:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309131 Vs 22:45:59 Temperature Measurement, Probe Number = 0, T = 20.133000 C 22:46:00 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:46:00 Temperature Measurement, Probe Number = 2, T = 20.002000 C 22:46:01 Temperature Measurement, Probe Number = 3, T = 19.987000 C 22:46:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:46:01 Integrated Voltage Measurement... 22:46:20 Voltage Offset Correction: v_off_ini = 0.000001422 V, v_off_fin = 0.000006352 V 22:46:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426500 Vs 22:46:21 Integrated Voltage Measurement... 22:46:40 Voltage Offset Correction: v_off_ini = 0.000005756 V, v_off_fin = -0.000001474 V 22:46:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301872 Vs 22:46:43 Temperature Measurement, Probe Number = 0, T = 20.174000 C 22:46:43 Temperature Measurement, Probe Number = 1, T = 20.036000 C 22:46:44 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:46:45 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:46:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:46:45 Integrated Voltage Measurement... 22:47:04 Voltage Offset Correction: v_off_ini = 0.000001879 V, v_off_fin = 0.000006860 V 22:47:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432969 Vs 22:47:04 Integrated Voltage Measurement... 22:47:23 Voltage Offset Correction: v_off_ini = 0.000005689 V, v_off_fin = -0.000001729 V 22:47:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306216 Vs 23:17:26 Temperature Measurement, Probe Number = 0, T = 20.209000 C 23:17:27 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:17:28 Temperature Measurement, Probe Number = 2, T = 20.001000 C 23:17:28 Temperature Measurement, Probe Number = 3, T = 19.987000 C 23:17:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:17:28 Integrated Voltage Measurement... 23:17:48 Voltage Offset Correction: v_off_ini = 0.000004482 V, v_off_fin = 0.000006831 V 23:17:48 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175525199 Vs 23:17:48 Integrated Voltage Measurement... 23:18:07 Voltage Offset Correction: v_off_ini = 0.000006223 V, v_off_fin = -0.000001138 V 23:18:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298411 Vs 23:18:10 Temperature Measurement, Probe Number = 0, T = 20.189000 C 23:18:11 Temperature Measurement, Probe Number = 1, T = 20.034000 C 23:18:11 Temperature Measurement, Probe Number = 2, T = 20.002000 C 23:18:12 Temperature Measurement, Probe Number = 3, T = 19.988000 C 23:18:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:18:12 Integrated Voltage Measurement... 23:18:32 Voltage Offset Correction: v_off_ini = 0.000001596 V, v_off_fin = 0.000006411 V 23:18:32 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433108 Vs 23:18:32 Integrated Voltage Measurement... 23:18:51 Voltage Offset Correction: v_off_ini = 0.000005478 V, v_off_fin = -0.000001370 V 23:18:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300496 Vs 23:18:54 Temperature Measurement, Probe Number = 0, T = 20.218000 C 23:18:55 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:18:56 Temperature Measurement, Probe Number = 2, T = 20.001000 C 23:18:56 Temperature Measurement, Probe Number = 3, T = 19.984000 C 23:18:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 23:18:56 Integrated Voltage Measurement... 23:19:16 Voltage Offset Correction: v_off_ini = 0.000001785 V, v_off_fin = 0.000006781 V 23:19:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437138 Vs 23:19:16 Integrated Voltage Measurement... 23:19:35 Voltage Offset Correction: v_off_ini = 0.000005644 V, v_off_fin = -0.000001830 V 23:19:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302911 Vs 23:19:38 Temperature Measurement, Probe Number = 0, T = 20.221000 C 23:19:39 Temperature Measurement, Probe Number = 1, T = 20.035000 C 23:19:40 Temperature Measurement, Probe Number = 2, T = 20.002000 C 23:19:40 Temperature Measurement, Probe Number = 3, T = 19.987000 C 23:19:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:19:40 Integrated Voltage Measurement... 23:20:00 Voltage Offset Correction: v_off_ini = 0.000002270 V, v_off_fin = 0.000006427 V 23:20:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435244 Vs 23:20:00 Integrated Voltage Measurement... 23:20:19 Voltage Offset Correction: v_off_ini = 0.000006125 V, v_off_fin = -0.000001795 V 23:20:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292008 Vs 23:20:22 Temperature Measurement, Probe Number = 0, T = 20.229000 C 23:20:23 Temperature Measurement, Probe Number = 1, T = 20.036000 C 23:20:23 Temperature Measurement, Probe Number = 2, T = 20.004000 C 23:20:24 Temperature Measurement, Probe Number = 3, T = 19.989000 C 23:20:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:20:24 Integrated Voltage Measurement... 23:20:43 Voltage Offset Correction: v_off_ini = 0.000002629 V, v_off_fin = 0.000007345 V 23:20:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441988 Vs 23:20:43 Integrated Voltage Measurement... 23:21:03 Voltage Offset Correction: v_off_ini = 0.000006373 V, v_off_fin = -0.000001826 V 23:21:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307207 Vs 23:21:05 Temperature Measurement, Probe Number = 0, T = 20.259000 C 23:21:06 Temperature Measurement, Probe Number = 1, T = 20.039000 C 23:21:07 Temperature Measurement, Probe Number = 2, T = 20.006000 C 23:21:07 Temperature Measurement, Probe Number = 3, T = 19.990000 C 23:21:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 23:21:08 Integrated Voltage Measurement... 23:21:27 Voltage Offset Correction: v_off_ini = 0.000002237 V, v_off_fin = 0.000006279 V 23:21:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439053 Vs 23:21:27 Integrated Voltage Measurement... 23:21:47 Voltage Offset Correction: v_off_ini = 0.000005975 V, v_off_fin = -0.000001339 V 23:21:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307560 Vs 23:21:50 Temperature Measurement, Probe Number = 0, T = 20.330000 C 23:21:50 Temperature Measurement, Probe Number = 1, T = 20.037000 C 23:21:51 Temperature Measurement, Probe Number = 2, T = 20.007000 C 23:21:52 Temperature Measurement, Probe Number = 3, T = 19.989000 C 23:21:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 23:21:52 Integrated Voltage Measurement... 23:22:11 Voltage Offset Correction: v_off_ini = 0.000002262 V, v_off_fin = 0.000007102 V 23:22:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435436 Vs 23:22:11 Integrated Voltage Measurement... 23:22:31 Voltage Offset Correction: v_off_ini = 0.000006012 V, v_off_fin = -0.000001602 V 23:22:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305413 Vs 23:22:33 Temperature Measurement, Probe Number = 0, T = 20.285000 C 23:22:34 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:22:35 Temperature Measurement, Probe Number = 2, T = 20.000000 C 23:22:35 Temperature Measurement, Probe Number = 3, T = 19.986000 C 23:22:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:22:36 Integrated Voltage Measurement... 23:22:55 Voltage Offset Correction: v_off_ini = 0.000001402 V, v_off_fin = 0.000005929 V 23:22:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436885 Vs 23:22:55 Integrated Voltage Measurement... 23:23:14 Voltage Offset Correction: v_off_ini = 0.000005027 V, v_off_fin = -0.000001591 V 23:23:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306741 Vs 23:23:17 Temperature Measurement, Probe Number = 0, T = 20.262000 C 23:23:18 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:23:18 Temperature Measurement, Probe Number = 2, T = 20.001000 C 23:23:19 Temperature Measurement, Probe Number = 3, T = 19.986000 C 23:23:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:23:19 Integrated Voltage Measurement... 23:23:38 Voltage Offset Correction: v_off_ini = 0.000001245 V, v_off_fin = 0.000006805 V 23:23:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437312 Vs 23:23:38 Integrated Voltage Measurement... 23:23:57 Voltage Offset Correction: v_off_ini = 0.000005723 V, v_off_fin = -0.000001894 V 23:23:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302358 Vs 23:24:00 Temperature Measurement, Probe Number = 0, T = 20.243000 C 23:24:01 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:24:01 Temperature Measurement, Probe Number = 2, T = 19.999000 C 23:24:02 Temperature Measurement, Probe Number = 3, T = 19.984000 C 23:24:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 23:24:02 Integrated Voltage Measurement... 23:24:23 Voltage Offset Correction: v_off_ini = 0.000002232 V, v_off_fin = 0.000006170 V 23:24:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440135 Vs 23:24:23 Integrated Voltage Measurement... 23:24:43 Voltage Offset Correction: v_off_ini = 0.000005648 V, v_off_fin = -0.000001397 V 23:24:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295817 Vs 23:54:45 Temperature Measurement, Probe Number = 0, T = 20.273000 C 23:54:46 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:54:47 Temperature Measurement, Probe Number = 2, T = 20.002000 C 23:54:47 Temperature Measurement, Probe Number = 3, T = 19.987000 C 23:54:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:54:48 Integrated Voltage Measurement... 23:55:07 Voltage Offset Correction: v_off_ini = 0.000004080 V, v_off_fin = 0.000007436 V 23:55:07 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175531238 Vs 23:55:07 Integrated Voltage Measurement... 23:55:26 Voltage Offset Correction: v_off_ini = 0.000006289 V, v_off_fin = -0.000001093 V 23:55:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294015 Vs 23:55:29 Temperature Measurement, Probe Number = 0, T = 20.268000 C 23:55:30 Temperature Measurement, Probe Number = 1, T = 20.036000 C 23:55:30 Temperature Measurement, Probe Number = 2, T = 20.005000 C 23:55:31 Temperature Measurement, Probe Number = 3, T = 19.990000 C 23:55:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:55:31 Integrated Voltage Measurement... 23:55:50 Voltage Offset Correction: v_off_ini = 0.000002727 V, v_off_fin = 0.000006921 V 23:55:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439549 Vs 23:55:51 Integrated Voltage Measurement... 23:56:10 Voltage Offset Correction: v_off_ini = 0.000006265 V, v_off_fin = -0.000001095 V 23:56:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298016 Vs 23:56:13 Temperature Measurement, Probe Number = 0, T = 20.254000 C 23:56:13 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:56:14 Temperature Measurement, Probe Number = 2, T = 20.000000 C 23:56:15 Temperature Measurement, Probe Number = 3, T = 19.984000 C 23:56:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 23:56:15 Integrated Voltage Measurement... 23:56:34 Voltage Offset Correction: v_off_ini = 0.000002076 V, v_off_fin = 0.000006372 V 23:56:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433559 Vs 23:56:34 Integrated Voltage Measurement... 23:56:53 Voltage Offset Correction: v_off_ini = 0.000005482 V, v_off_fin = -0.000001911 V 23:56:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299441 Vs 23:56:56 Temperature Measurement, Probe Number = 0, T = 20.205000 C 23:56:57 Temperature Measurement, Probe Number = 1, T = 20.034000 C 23:56:58 Temperature Measurement, Probe Number = 2, T = 20.002000 C 23:56:58 Temperature Measurement, Probe Number = 3, T = 19.986000 C 23:56:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:56:58 Integrated Voltage Measurement... 23:57:18 Voltage Offset Correction: v_off_ini = 0.000001494 V, v_off_fin = 0.000006764 V 23:57:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438015 Vs 23:57:18 Integrated Voltage Measurement... 23:57:37 Voltage Offset Correction: v_off_ini = 0.000006131 V, v_off_fin = -0.000001408 V 23:57:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292136 Vs 23:57:40 Temperature Measurement, Probe Number = 0, T = 20.197000 C 23:57:41 Temperature Measurement, Probe Number = 1, T = 20.036000 C 23:57:41 Temperature Measurement, Probe Number = 2, T = 20.006000 C 23:57:42 Temperature Measurement, Probe Number = 3, T = 19.990000 C 23:57:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 23:57:42 Integrated Voltage Measurement... 23:58:02 Voltage Offset Correction: v_off_ini = 0.000002076 V, v_off_fin = 0.000006292 V 23:58:02 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436941 Vs 23:58:02 Integrated Voltage Measurement... 23:58:21 Voltage Offset Correction: v_off_ini = 0.000005557 V, v_off_fin = -0.000002226 V 23:58:21 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175299087 Vs 23:58:24 Temperature Measurement, Probe Number = 0, T = 20.272000 C 23:58:25 Temperature Measurement, Probe Number = 1, T = 20.034000 C 23:58:25 Temperature Measurement, Probe Number = 2, T = 20.007000 C 23:58:26 Temperature Measurement, Probe Number = 3, T = 19.991000 C 23:58:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 23:58:26 Integrated Voltage Measurement... 23:58:45 Voltage Offset Correction: v_off_ini = 0.000002099 V, v_off_fin = 0.000006051 V 23:58:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435092 Vs 23:58:46 Integrated Voltage Measurement... 23:59:05 Voltage Offset Correction: v_off_ini = 0.000005523 V, v_off_fin = -0.000001446 V 23:59:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298845 Vs 23:59:07 Temperature Measurement, Probe Number = 0, T = 20.319000 C 23:59:08 Temperature Measurement, Probe Number = 1, T = 20.032000 C 23:59:09 Temperature Measurement, Probe Number = 2, T = 20.004000 C 23:59:09 Temperature Measurement, Probe Number = 3, T = 19.987000 C 23:59:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:59:10 Integrated Voltage Measurement... 23:59:29 Voltage Offset Correction: v_off_ini = 0.000002300 V, v_off_fin = 0.000006539 V 23:59:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434237 Vs 23:59:29 Integrated Voltage Measurement... 23:59:48 Voltage Offset Correction: v_off_ini = 0.000005936 V, v_off_fin = -0.000001142 V 23:59:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294781 Vs 23:59:51 Temperature Measurement, Probe Number = 0, T = 20.287000 C 23:59:51 Temperature Measurement, Probe Number = 1, T = 20.033000 C 23:59:52 Temperature Measurement, Probe Number = 2, T = 20.005000 C 23:59:53 Temperature Measurement, Probe Number = 3, T = 19.987000 C 23:59:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 23:59:53 Integrated Voltage Measurement... 00:00:12 Voltage Offset Correction: v_off_ini = 0.000002991 V, v_off_fin = 0.000006960 V 00:00:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439989 Vs 00:00:12 Integrated Voltage Measurement... 00:00:32 Voltage Offset Correction: v_off_ini = 0.000006140 V, v_off_fin = -0.000001024 V 00:00:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293301 Vs 00:00:35 Temperature Measurement, Probe Number = 0, T = 20.269000 C 00:00:35 Temperature Measurement, Probe Number = 1, T = 20.034000 C 00:00:36 Temperature Measurement, Probe Number = 2, T = 20.004000 C 00:00:37 Temperature Measurement, Probe Number = 3, T = 19.989000 C 00:00:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 00:00:37 Integrated Voltage Measurement... 00:00:56 Voltage Offset Correction: v_off_ini = 0.000002551 V, v_off_fin = 0.000006703 V 00:00:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443233 Vs 00:00:57 Integrated Voltage Measurement... 00:01:16 Voltage Offset Correction: v_off_ini = 0.000005994 V, v_off_fin = -0.000001636 V 00:01:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308062 Vs 00:01:19 Temperature Measurement, Probe Number = 0, T = 20.227000 C 00:01:20 Temperature Measurement, Probe Number = 1, T = 20.032000 C 00:01:21 Temperature Measurement, Probe Number = 2, T = 19.999000 C 00:01:21 Temperature Measurement, Probe Number = 3, T = 19.985000 C 00:01:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:01:21 Integrated Voltage Measurement... 00:01:41 Voltage Offset Correction: v_off_ini = 0.000002465 V, v_off_fin = 0.000006287 V 00:01:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437025 Vs 00:01:41 Integrated Voltage Measurement... 00:02:00 Voltage Offset Correction: v_off_ini = 0.000005535 V, v_off_fin = -0.000001176 V 00:02:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313329 Vs 00:32:03 Temperature Measurement, Probe Number = 0, T = 20.171000 C 00:32:04 Temperature Measurement, Probe Number = 1, T = 20.028000 C 00:32:04 Temperature Measurement, Probe Number = 2, T = 19.995000 C 00:32:05 Temperature Measurement, Probe Number = 3, T = 19.984000 C 00:32:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:32:05 Integrated Voltage Measurement... 00:32:25 Voltage Offset Correction: v_off_ini = 0.000004402 V, v_off_fin = 0.000007122 V 00:32:25 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175527744 Vs 00:32:25 Integrated Voltage Measurement... 00:32:44 Voltage Offset Correction: v_off_ini = 0.000006157 V, v_off_fin = -0.000001652 V 00:32:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296936 Vs 00:32:47 Temperature Measurement, Probe Number = 0, T = 20.193000 C 00:32:48 Temperature Measurement, Probe Number = 1, T = 20.029000 C 00:32:48 Temperature Measurement, Probe Number = 2, T = 19.997000 C 00:32:49 Temperature Measurement, Probe Number = 3, T = 19.982000 C 00:32:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:32:49 Integrated Voltage Measurement... 00:33:09 Voltage Offset Correction: v_off_ini = 0.000002478 V, v_off_fin = 0.000006758 V 00:33:09 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438582 Vs 00:33:09 Integrated Voltage Measurement... 00:33:28 Voltage Offset Correction: v_off_ini = 0.000005948 V, v_off_fin = -0.000001661 V 00:33:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305955 Vs 00:33:31 Temperature Measurement, Probe Number = 0, T = 20.189000 C 00:33:32 Temperature Measurement, Probe Number = 1, T = 20.029000 C 00:33:32 Temperature Measurement, Probe Number = 2, T = 20.001000 C 00:33:33 Temperature Measurement, Probe Number = 3, T = 19.987000 C 00:33:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 00:33:33 Integrated Voltage Measurement... 00:33:53 Voltage Offset Correction: v_off_ini = 0.000001797 V, v_off_fin = 0.000006476 V 00:33:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438198 Vs 00:33:53 Integrated Voltage Measurement... 00:34:12 Voltage Offset Correction: v_off_ini = 0.000005879 V, v_off_fin = -0.000001525 V 00:34:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300720 Vs 00:34:15 Temperature Measurement, Probe Number = 0, T = 20.212000 C 00:34:15 Temperature Measurement, Probe Number = 1, T = 20.024000 C 00:34:16 Temperature Measurement, Probe Number = 2, T = 19.996000 C 00:34:17 Temperature Measurement, Probe Number = 3, T = 19.980000 C 00:34:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:34:17 Integrated Voltage Measurement... 00:34:36 Voltage Offset Correction: v_off_ini = 0.000002273 V, v_off_fin = 0.000006542 V 00:34:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442826 Vs 00:34:37 Integrated Voltage Measurement... 00:34:56 Voltage Offset Correction: v_off_ini = 0.000005886 V, v_off_fin = -0.000002253 V 00:34:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301291 Vs 00:34:58 Temperature Measurement, Probe Number = 0, T = 20.147000 C 00:34:59 Temperature Measurement, Probe Number = 1, T = 20.023000 C 00:35:00 Temperature Measurement, Probe Number = 2, T = 19.993000 C 00:35:00 Temperature Measurement, Probe Number = 3, T = 19.976000 C 00:35:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:35:01 Integrated Voltage Measurement... 00:35:20 Voltage Offset Correction: v_off_ini = 0.000002039 V, v_off_fin = 0.000006343 V 00:35:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439383 Vs 00:35:20 Integrated Voltage Measurement... 00:35:39 Voltage Offset Correction: v_off_ini = 0.000006129 V, v_off_fin = -0.000001699 V 00:35:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301166 Vs 00:35:42 Temperature Measurement, Probe Number = 0, T = 20.059000 C 00:35:42 Temperature Measurement, Probe Number = 1, T = 20.023000 C 00:35:43 Temperature Measurement, Probe Number = 2, T = 19.993000 C 00:35:44 Temperature Measurement, Probe Number = 3, T = 19.976000 C 00:35:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:35:44 Integrated Voltage Measurement... 00:36:03 Voltage Offset Correction: v_off_ini = 0.000002263 V, v_off_fin = 0.000006938 V 00:36:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439090 Vs 00:36:03 Integrated Voltage Measurement... 00:36:23 Voltage Offset Correction: v_off_ini = 0.000005720 V, v_off_fin = -0.000001725 V 00:36:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307907 Vs 00:36:25 Temperature Measurement, Probe Number = 0, T = 19.973000 C 00:36:26 Temperature Measurement, Probe Number = 1, T = 20.025000 C 00:36:27 Temperature Measurement, Probe Number = 2, T = 19.995000 C 00:36:27 Temperature Measurement, Probe Number = 3, T = 19.980000 C 00:36:27 Magnet Test Parameter Measurements P0 = Room, Value = 19.97 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:36:27 Integrated Voltage Measurement... 00:36:47 Voltage Offset Correction: v_off_ini = 0.000002047 V, v_off_fin = 0.000006599 V 00:36:47 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436835 Vs 00:36:47 Integrated Voltage Measurement... 00:37:07 Voltage Offset Correction: v_off_ini = 0.000005899 V, v_off_fin = -0.000002019 V 00:37:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313835 Vs 00:37:09 Temperature Measurement, Probe Number = 0, T = 19.960000 C 00:37:10 Temperature Measurement, Probe Number = 1, T = 20.025000 C 00:37:11 Temperature Measurement, Probe Number = 2, T = 19.994000 C 00:37:11 Temperature Measurement, Probe Number = 3, T = 19.975000 C 00:37:11 Magnet Test Parameter Measurements P0 = Room, Value = 19.96 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:37:11 Integrated Voltage Measurement... 00:37:31 Voltage Offset Correction: v_off_ini = 0.000002115 V, v_off_fin = 0.000006501 V 00:37:31 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433705 Vs 00:37:31 Integrated Voltage Measurement... 00:37:50 Voltage Offset Correction: v_off_ini = 0.000005837 V, v_off_fin = -0.000001821 V 00:37:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301579 Vs 00:37:53 Temperature Measurement, Probe Number = 0, T = 20.047000 C 00:37:54 Temperature Measurement, Probe Number = 1, T = 20.028000 C 00:37:54 Temperature Measurement, Probe Number = 2, T = 19.997000 C 00:37:55 Temperature Measurement, Probe Number = 3, T = 19.980000 C 00:37:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:37:55 Integrated Voltage Measurement... 00:38:14 Voltage Offset Correction: v_off_ini = 0.000001737 V, v_off_fin = 0.000006398 V 00:38:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436261 Vs 00:38:14 Integrated Voltage Measurement... 00:38:34 Voltage Offset Correction: v_off_ini = 0.000005663 V, v_off_fin = -0.000001418 V 00:38:34 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304959 Vs 00:38:37 Temperature Measurement, Probe Number = 0, T = 20.143000 C 00:38:37 Temperature Measurement, Probe Number = 1, T = 20.029000 C 00:38:38 Temperature Measurement, Probe Number = 2, T = 19.998000 C 00:38:38 Temperature Measurement, Probe Number = 3, T = 19.982000 C 00:38:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 00:38:39 Integrated Voltage Measurement... 00:38:58 Voltage Offset Correction: v_off_ini = 0.000002035 V, v_off_fin = 0.000006705 V 00:38:58 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175441652 Vs 00:38:58 Integrated Voltage Measurement... 00:39:18 Voltage Offset Correction: v_off_ini = 0.000006063 V, v_off_fin = -0.000001250 V 00:39:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305742 Vs 01:09:21 Temperature Measurement, Probe Number = 0, T = 20.306000 C 01:09:21 Temperature Measurement, Probe Number = 1, T = 20.031000 C 01:09:22 Temperature Measurement, Probe Number = 2, T = 20.001000 C 01:09:23 Temperature Measurement, Probe Number = 3, T = 19.986000 C 01:09:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:09:23 Integrated Voltage Measurement... 01:09:42 Voltage Offset Correction: v_off_ini = 0.000004431 V, v_off_fin = 0.000006608 V 01:09:42 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175521663 Vs 01:09:42 Integrated Voltage Measurement... 01:10:01 Voltage Offset Correction: v_off_ini = 0.000006039 V, v_off_fin = -0.000001868 V 01:10:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287980 Vs 01:10:04 Temperature Measurement, Probe Number = 0, T = 20.294000 C 01:10:05 Temperature Measurement, Probe Number = 1, T = 20.034000 C 01:10:05 Temperature Measurement, Probe Number = 2, T = 20.005000 C 01:10:06 Temperature Measurement, Probe Number = 3, T = 19.987000 C 01:10:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:10:06 Integrated Voltage Measurement... 01:10:25 Voltage Offset Correction: v_off_ini = 0.000001535 V, v_off_fin = 0.000006349 V 01:10:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427423 Vs 01:10:25 Integrated Voltage Measurement... 01:10:45 Voltage Offset Correction: v_off_ini = 0.000005584 V, v_off_fin = -0.000001319 V 01:10:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299686 Vs 01:10:48 Temperature Measurement, Probe Number = 0, T = 20.316000 C 01:10:48 Temperature Measurement, Probe Number = 1, T = 20.035000 C 01:10:49 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:10:50 Temperature Measurement, Probe Number = 3, T = 19.988000 C 01:10:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:10:50 Integrated Voltage Measurement... 01:11:09 Voltage Offset Correction: v_off_ini = 0.000002199 V, v_off_fin = 0.000006694 V 01:11:09 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427805 Vs 01:11:10 Integrated Voltage Measurement... 01:11:29 Voltage Offset Correction: v_off_ini = 0.000005791 V, v_off_fin = -0.000001245 V 01:11:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293371 Vs 01:11:32 Temperature Measurement, Probe Number = 0, T = 20.370000 C 01:11:33 Temperature Measurement, Probe Number = 1, T = 20.037000 C 01:11:33 Temperature Measurement, Probe Number = 2, T = 20.009000 C 01:11:34 Temperature Measurement, Probe Number = 3, T = 19.989000 C 01:11:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:11:34 Integrated Voltage Measurement... 01:11:53 Voltage Offset Correction: v_off_ini = 0.000002201 V, v_off_fin = 0.000006630 V 01:11:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175419075 Vs 01:11:53 Integrated Voltage Measurement... 01:12:13 Voltage Offset Correction: v_off_ini = 0.000005968 V, v_off_fin = -0.000001651 V 01:12:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299097 Vs 01:12:16 Temperature Measurement, Probe Number = 0, T = 20.397000 C 01:12:16 Temperature Measurement, Probe Number = 1, T = 20.037000 C 01:12:17 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:12:18 Temperature Measurement, Probe Number = 3, T = 19.989000 C 01:12:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:12:18 Integrated Voltage Measurement... 01:12:37 Voltage Offset Correction: v_off_ini = 0.000002148 V, v_off_fin = 0.000006271 V 01:12:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422962 Vs 01:12:37 Integrated Voltage Measurement... 01:12:57 Voltage Offset Correction: v_off_ini = 0.000006163 V, v_off_fin = -0.000002227 V 01:12:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294679 Vs 01:13:00 Temperature Measurement, Probe Number = 0, T = 20.373000 C 01:13:00 Temperature Measurement, Probe Number = 1, T = 20.036000 C 01:13:01 Temperature Measurement, Probe Number = 2, T = 20.005000 C 01:13:02 Temperature Measurement, Probe Number = 3, T = 19.987000 C 01:13:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:13:02 Integrated Voltage Measurement... 01:13:21 Voltage Offset Correction: v_off_ini = 0.000001682 V, v_off_fin = 0.000006176 V 01:13:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420076 Vs 01:13:22 Integrated Voltage Measurement... 01:13:41 Voltage Offset Correction: v_off_ini = 0.000005430 V, v_off_fin = -0.000001315 V 01:13:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303192 Vs 01:13:44 Temperature Measurement, Probe Number = 0, T = 20.383000 C 01:13:44 Temperature Measurement, Probe Number = 1, T = 20.035000 C 01:13:45 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:13:46 Temperature Measurement, Probe Number = 3, T = 19.988000 C 01:13:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:13:46 Integrated Voltage Measurement... 01:14:05 Voltage Offset Correction: v_off_ini = 0.000002005 V, v_off_fin = 0.000006879 V 01:14:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425735 Vs 01:14:06 Integrated Voltage Measurement... 01:14:25 Voltage Offset Correction: v_off_ini = 0.000005877 V, v_off_fin = -0.000001914 V 01:14:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295187 Vs 01:14:28 Temperature Measurement, Probe Number = 0, T = 20.406000 C 01:14:29 Temperature Measurement, Probe Number = 1, T = 20.035000 C 01:14:29 Temperature Measurement, Probe Number = 2, T = 20.006000 C 01:14:30 Temperature Measurement, Probe Number = 3, T = 19.988000 C 01:14:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:14:30 Integrated Voltage Measurement... 01:14:49 Voltage Offset Correction: v_off_ini = 0.000002156 V, v_off_fin = 0.000006807 V 01:14:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422143 Vs 01:14:49 Integrated Voltage Measurement... 01:15:08 Voltage Offset Correction: v_off_ini = 0.000005718 V, v_off_fin = -0.000001574 V 01:15:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288257 Vs 01:15:11 Temperature Measurement, Probe Number = 0, T = 20.405000 C 01:15:12 Temperature Measurement, Probe Number = 1, T = 20.034000 C 01:15:13 Temperature Measurement, Probe Number = 2, T = 20.007000 C 01:15:13 Temperature Measurement, Probe Number = 3, T = 19.988000 C 01:15:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:15:13 Integrated Voltage Measurement... 01:15:32 Voltage Offset Correction: v_off_ini = 0.000001807 V, v_off_fin = 0.000006153 V 01:15:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421932 Vs 01:15:33 Integrated Voltage Measurement... 01:15:52 Voltage Offset Correction: v_off_ini = 0.000005566 V, v_off_fin = -0.000001622 V 01:15:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286649 Vs 01:15:55 Temperature Measurement, Probe Number = 0, T = 20.398000 C 01:15:55 Temperature Measurement, Probe Number = 1, T = 20.034000 C 01:15:56 Temperature Measurement, Probe Number = 2, T = 20.006000 C 01:15:56 Temperature Measurement, Probe Number = 3, T = 19.988000 C 01:15:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 01:15:57 Integrated Voltage Measurement... 01:16:16 Voltage Offset Correction: v_off_ini = 0.000000735 V, v_off_fin = 0.000006197 V 01:16:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421600 Vs 01:16:16 Integrated Voltage Measurement... 01:16:36 Voltage Offset Correction: v_off_ini = 0.000005249 V, v_off_fin = -0.000001466 V 01:16:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290835 Vs 01:46:38 Temperature Measurement, Probe Number = 0, T = 20.109000 C 01:46:39 Temperature Measurement, Probe Number = 1, T = 20.023000 C 01:46:40 Temperature Measurement, Probe Number = 2, T = 19.989000 C 01:46:40 Temperature Measurement, Probe Number = 3, T = 19.974000 C 01:46:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:46:40 Integrated Voltage Measurement... 01:47:00 Voltage Offset Correction: v_off_ini = 0.000005515 V, v_off_fin = 0.000007378 V 01:47:00 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175527986 Vs 01:47:00 Integrated Voltage Measurement... 01:47:19 Voltage Offset Correction: v_off_ini = 0.000006772 V, v_off_fin = -0.000000488 V 01:47:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175289424 Vs 01:47:22 Temperature Measurement, Probe Number = 0, T = 20.124000 C 01:47:23 Temperature Measurement, Probe Number = 1, T = 20.022000 C 01:47:23 Temperature Measurement, Probe Number = 2, T = 19.992000 C 01:47:24 Temperature Measurement, Probe Number = 3, T = 19.974000 C 01:47:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:47:24 Integrated Voltage Measurement... 01:47:43 Voltage Offset Correction: v_off_ini = 0.000002422 V, v_off_fin = 0.000006923 V 01:47:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175435280 Vs 01:47:44 Integrated Voltage Measurement... 01:48:03 Voltage Offset Correction: v_off_ini = 0.000006100 V, v_off_fin = -0.000000889 V 01:48:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294708 Vs 01:48:05 Temperature Measurement, Probe Number = 0, T = 20.100000 C 01:48:06 Temperature Measurement, Probe Number = 1, T = 20.022000 C 01:48:07 Temperature Measurement, Probe Number = 2, T = 19.990000 C 01:48:07 Temperature Measurement, Probe Number = 3, T = 19.973000 C 01:48:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:48:08 Integrated Voltage Measurement... 01:48:27 Voltage Offset Correction: v_off_ini = 0.000002665 V, v_off_fin = 0.000006695 V 01:48:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442183 Vs 01:48:27 Integrated Voltage Measurement... 01:48:46 Voltage Offset Correction: v_off_ini = 0.000006384 V, v_off_fin = -0.000001896 V 01:48:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295649 Vs 01:48:49 Temperature Measurement, Probe Number = 0, T = 20.119000 C 01:48:50 Temperature Measurement, Probe Number = 1, T = 20.023000 C 01:48:50 Temperature Measurement, Probe Number = 2, T = 19.992000 C 01:48:51 Temperature Measurement, Probe Number = 3, T = 19.974000 C 01:48:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:48:51 Integrated Voltage Measurement... 01:49:11 Voltage Offset Correction: v_off_ini = 0.000002604 V, v_off_fin = 0.000006968 V 01:49:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175434534 Vs 01:49:11 Integrated Voltage Measurement... 01:49:30 Voltage Offset Correction: v_off_ini = 0.000006984 V, v_off_fin = -0.000001491 V 01:49:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299843 Vs 01:49:33 Temperature Measurement, Probe Number = 0, T = 20.113000 C 01:49:34 Temperature Measurement, Probe Number = 1, T = 20.027000 C 01:49:34 Temperature Measurement, Probe Number = 2, T = 19.995000 C 01:49:35 Temperature Measurement, Probe Number = 3, T = 19.977000 C 01:49:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 01:49:35 Integrated Voltage Measurement... 01:49:54 Voltage Offset Correction: v_off_ini = 0.000003014 V, v_off_fin = 0.000006758 V 01:49:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175434091 Vs 01:49:55 Integrated Voltage Measurement... 01:50:14 Voltage Offset Correction: v_off_ini = 0.000006189 V, v_off_fin = -0.000001455 V 01:50:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290097 Vs 01:50:16 Temperature Measurement, Probe Number = 0, T = 20.210000 C 01:50:17 Temperature Measurement, Probe Number = 1, T = 20.028000 C 01:50:18 Temperature Measurement, Probe Number = 2, T = 19.994000 C 01:50:18 Temperature Measurement, Probe Number = 3, T = 19.977000 C 01:50:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 01:50:18 Integrated Voltage Measurement... 01:50:38 Voltage Offset Correction: v_off_ini = 0.000003160 V, v_off_fin = 0.000007243 V 01:50:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440646 Vs 01:50:38 Integrated Voltage Measurement... 01:50:57 Voltage Offset Correction: v_off_ini = 0.000006114 V, v_off_fin = -0.000001462 V 01:50:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288886 Vs 01:51:00 Temperature Measurement, Probe Number = 0, T = 20.191000 C 01:51:00 Temperature Measurement, Probe Number = 1, T = 20.025000 C 01:51:01 Temperature Measurement, Probe Number = 2, T = 19.993000 C 01:51:02 Temperature Measurement, Probe Number = 3, T = 19.976000 C 01:51:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 01:51:02 Integrated Voltage Measurement... 01:51:21 Voltage Offset Correction: v_off_ini = 0.000002817 V, v_off_fin = 0.000007533 V 01:51:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438402 Vs 01:51:21 Integrated Voltage Measurement... 01:51:41 Voltage Offset Correction: v_off_ini = 0.000006523 V, v_off_fin = 0.000000079 V 01:51:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175291450 Vs 01:51:44 Temperature Measurement, Probe Number = 0, T = 20.172000 C 01:51:44 Temperature Measurement, Probe Number = 1, T = 20.023000 C 01:51:45 Temperature Measurement, Probe Number = 2, T = 19.994000 C 01:51:45 Temperature Measurement, Probe Number = 3, T = 19.976000 C 01:51:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 01:51:46 Integrated Voltage Measurement... 01:52:05 Voltage Offset Correction: v_off_ini = 0.000003073 V, v_off_fin = 0.000006647 V 01:52:05 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175433327 Vs 01:52:05 Integrated Voltage Measurement... 01:52:25 Voltage Offset Correction: v_off_ini = 0.000006285 V, v_off_fin = -0.000000441 V 01:52:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175292978 Vs 01:52:27 Temperature Measurement, Probe Number = 0, T = 20.169000 C 01:52:28 Temperature Measurement, Probe Number = 1, T = 20.023000 C 01:52:29 Temperature Measurement, Probe Number = 2, T = 19.989000 C 01:52:29 Temperature Measurement, Probe Number = 3, T = 19.977000 C 01:52:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 01:52:30 Integrated Voltage Measurement... 01:52:49 Voltage Offset Correction: v_off_ini = 0.000002590 V, v_off_fin = 0.000007479 V 01:52:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444022 Vs 01:52:49 Integrated Voltage Measurement... 01:53:08 Voltage Offset Correction: v_off_ini = 0.000006663 V, v_off_fin = -0.000000493 V 01:53:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283924 Vs 01:53:11 Temperature Measurement, Probe Number = 0, T = 20.225000 C 01:53:12 Temperature Measurement, Probe Number = 1, T = 20.023000 C 01:53:12 Temperature Measurement, Probe Number = 2, T = 19.990000 C 01:53:13 Temperature Measurement, Probe Number = 3, T = 19.978000 C 01:53:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 01:53:13 Integrated Voltage Measurement... 01:53:33 Voltage Offset Correction: v_off_ini = 0.000002999 V, v_off_fin = 0.000007914 V 01:53:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453126 Vs 01:53:33 Integrated Voltage Measurement... 01:53:52 Voltage Offset Correction: v_off_ini = 0.000007303 V, v_off_fin = -0.000000444 V 01:53:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284666 Vs 02:23:55 Temperature Measurement, Probe Number = 0, T = 20.027000 C 02:23:56 Temperature Measurement, Probe Number = 1, T = 20.017000 C 02:23:56 Temperature Measurement, Probe Number = 2, T = 19.982000 C 02:23:57 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:23:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:23:57 Integrated Voltage Measurement... 02:24:16 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = 0.000007646 V 02:24:16 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175528230 Vs 02:24:16 Integrated Voltage Measurement... 02:24:36 Voltage Offset Correction: v_off_ini = 0.000006577 V, v_off_fin = -0.000000160 V 02:24:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175295403 Vs 02:24:38 Temperature Measurement, Probe Number = 0, T = 20.057000 C 02:24:39 Temperature Measurement, Probe Number = 1, T = 20.012000 C 02:24:40 Temperature Measurement, Probe Number = 2, T = 19.977000 C 02:24:40 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:24:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:24:41 Integrated Voltage Measurement... 02:25:00 Voltage Offset Correction: v_off_ini = 0.000002844 V, v_off_fin = 0.000006797 V 02:25:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175438457 Vs 02:25:00 Integrated Voltage Measurement... 02:25:20 Voltage Offset Correction: v_off_ini = 0.000005895 V, v_off_fin = 0.000000029 V 02:25:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298669 Vs 02:25:23 Temperature Measurement, Probe Number = 0, T = 20.056000 C 02:25:23 Temperature Measurement, Probe Number = 1, T = 20.016000 C 02:25:24 Temperature Measurement, Probe Number = 2, T = 19.983000 C 02:25:25 Temperature Measurement, Probe Number = 3, T = 19.965000 C 02:25:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:25:25 Integrated Voltage Measurement... 02:25:44 Voltage Offset Correction: v_off_ini = 0.000003193 V, v_off_fin = 0.000007377 V 02:25:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175442849 Vs 02:25:44 Integrated Voltage Measurement... 02:26:04 Voltage Offset Correction: v_off_ini = 0.000006541 V, v_off_fin = -0.000001092 V 02:26:04 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175298338 Vs 02:26:06 Temperature Measurement, Probe Number = 0, T = 20.037000 C 02:26:07 Temperature Measurement, Probe Number = 1, T = 20.015000 C 02:26:08 Temperature Measurement, Probe Number = 2, T = 19.987000 C 02:26:08 Temperature Measurement, Probe Number = 3, T = 19.970000 C 02:26:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:26:09 Integrated Voltage Measurement... 02:26:28 Voltage Offset Correction: v_off_ini = 0.000002659 V, v_off_fin = 0.000007255 V 02:26:28 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175445729 Vs 02:26:28 Integrated Voltage Measurement... 02:26:48 Voltage Offset Correction: v_off_ini = 0.000006444 V, v_off_fin = -0.000001063 V 02:26:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301375 Vs 02:26:51 Temperature Measurement, Probe Number = 0, T = 20.070000 C 02:26:51 Temperature Measurement, Probe Number = 1, T = 20.016000 C 02:26:52 Temperature Measurement, Probe Number = 2, T = 19.988000 C 02:26:53 Temperature Measurement, Probe Number = 3, T = 19.972000 C 02:26:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:26:53 Integrated Voltage Measurement... 02:27:12 Voltage Offset Correction: v_off_ini = 0.000002039 V, v_off_fin = 0.000007269 V 02:27:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436550 Vs 02:27:12 Integrated Voltage Measurement... 02:27:32 Voltage Offset Correction: v_off_ini = 0.000006331 V, v_off_fin = -0.000000757 V 02:27:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302722 Vs 02:27:35 Temperature Measurement, Probe Number = 0, T = 20.040000 C 02:27:35 Temperature Measurement, Probe Number = 1, T = 20.017000 C 02:27:36 Temperature Measurement, Probe Number = 2, T = 19.986000 C 02:27:37 Temperature Measurement, Probe Number = 3, T = 19.969000 C 02:27:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 02:27:37 Integrated Voltage Measurement... 02:27:56 Voltage Offset Correction: v_off_ini = 0.000002548 V, v_off_fin = 0.000006756 V 02:27:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442339 Vs 02:27:56 Integrated Voltage Measurement... 02:28:15 Voltage Offset Correction: v_off_ini = 0.000006167 V, v_off_fin = -0.000001268 V 02:28:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297690 Vs 02:28:18 Temperature Measurement, Probe Number = 0, T = 19.995000 C 02:28:19 Temperature Measurement, Probe Number = 1, T = 20.015000 C 02:28:20 Temperature Measurement, Probe Number = 2, T = 19.979000 C 02:28:20 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:28:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:28:20 Integrated Voltage Measurement... 02:28:39 Voltage Offset Correction: v_off_ini = 0.000002270 V, v_off_fin = 0.000006621 V 02:28:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440100 Vs 02:28:40 Integrated Voltage Measurement... 02:28:59 Voltage Offset Correction: v_off_ini = 0.000005923 V, v_off_fin = -0.000001690 V 02:28:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297497 Vs 02:29:02 Temperature Measurement, Probe Number = 0, T = 19.984000 C 02:29:02 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:29:03 Temperature Measurement, Probe Number = 2, T = 19.984000 C 02:29:04 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:29:04 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:29:04 Integrated Voltage Measurement... 02:29:23 Voltage Offset Correction: v_off_ini = 0.000002592 V, v_off_fin = 0.000006790 V 02:29:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437142 Vs 02:29:23 Integrated Voltage Measurement... 02:29:42 Voltage Offset Correction: v_off_ini = 0.000005685 V, v_off_fin = -0.000001507 V 02:29:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300108 Vs 02:29:45 Temperature Measurement, Probe Number = 0, T = 20.014000 C 02:29:46 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:29:46 Temperature Measurement, Probe Number = 2, T = 19.985000 C 02:29:47 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:29:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.01 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:29:47 Integrated Voltage Measurement... 02:30:06 Voltage Offset Correction: v_off_ini = 0.000002008 V, v_off_fin = 0.000007225 V 02:30:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437106 Vs 02:30:06 Integrated Voltage Measurement... 02:30:25 Voltage Offset Correction: v_off_ini = 0.000006304 V, v_off_fin = -0.000001105 V 02:30:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294777 Vs 02:30:28 Temperature Measurement, Probe Number = 0, T = 20.038000 C 02:30:29 Temperature Measurement, Probe Number = 1, T = 20.018000 C 02:30:30 Temperature Measurement, Probe Number = 2, T = 19.980000 C 02:30:30 Temperature Measurement, Probe Number = 3, T = 19.967000 C 02:30:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:30:31 Integrated Voltage Measurement... 02:30:50 Voltage Offset Correction: v_off_ini = 0.000002212 V, v_off_fin = 0.000006895 V 02:30:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446424 Vs 02:30:50 Integrated Voltage Measurement... 02:31:09 Voltage Offset Correction: v_off_ini = 0.000006328 V, v_off_fin = -0.000001880 V 02:31:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292231 Vs 03:01:12 Temperature Measurement, Probe Number = 0, T = 20.179000 C 03:01:13 Temperature Measurement, Probe Number = 1, T = 20.013000 C 03:01:14 Temperature Measurement, Probe Number = 2, T = 19.978000 C 03:01:15 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:01:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:01:15 Integrated Voltage Measurement... 03:01:34 Voltage Offset Correction: v_off_ini = 0.000004321 V, v_off_fin = 0.000007523 V 03:01:35 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175528639 Vs 03:01:36 Integrated Voltage Measurement... 03:01:55 Voltage Offset Correction: v_off_ini = 0.000006745 V, v_off_fin = -0.000000737 V 03:01:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296897 Vs 03:01:58 Temperature Measurement, Probe Number = 0, T = 20.164000 C 03:01:59 Temperature Measurement, Probe Number = 1, T = 20.014000 C 03:02:00 Temperature Measurement, Probe Number = 2, T = 19.981000 C 03:02:00 Temperature Measurement, Probe Number = 3, T = 19.964000 C 03:02:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:02:01 Integrated Voltage Measurement... 03:02:20 Voltage Offset Correction: v_off_ini = 0.000002566 V, v_off_fin = 0.000006502 V 03:02:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175434237 Vs 03:02:21 Integrated Voltage Measurement... 03:02:40 Voltage Offset Correction: v_off_ini = 0.000005745 V, v_off_fin = -0.000002026 V 03:02:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304493 Vs 03:02:43 Temperature Measurement, Probe Number = 0, T = 20.144000 C 03:02:43 Temperature Measurement, Probe Number = 1, T = 20.012000 C 03:02:44 Temperature Measurement, Probe Number = 2, T = 19.979000 C 03:02:45 Temperature Measurement, Probe Number = 3, T = 19.963000 C 03:02:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:02:45 Integrated Voltage Measurement... 03:03:04 Voltage Offset Correction: v_off_ini = 0.000001898 V, v_off_fin = 0.000006244 V 03:03:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429324 Vs 03:03:05 Integrated Voltage Measurement... 03:03:23 Voltage Offset Correction: v_off_ini = 0.000005468 V, v_off_fin = -0.000001711 V 03:03:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297571 Vs 03:03:26 Temperature Measurement, Probe Number = 0, T = 20.104000 C 03:03:27 Temperature Measurement, Probe Number = 1, T = 20.009000 C 03:03:27 Temperature Measurement, Probe Number = 2, T = 19.979000 C 03:03:28 Temperature Measurement, Probe Number = 3, T = 19.961000 C 03:03:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:03:28 Integrated Voltage Measurement... 03:03:47 Voltage Offset Correction: v_off_ini = 0.000002557 V, v_off_fin = 0.000007471 V 03:03:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446914 Vs 03:03:48 Integrated Voltage Measurement... 03:04:07 Voltage Offset Correction: v_off_ini = 0.000006438 V, v_off_fin = -0.000000817 V 03:04:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288809 Vs 03:04:10 Temperature Measurement, Probe Number = 0, T = 20.029000 C 03:04:10 Temperature Measurement, Probe Number = 1, T = 20.011000 C 03:04:11 Temperature Measurement, Probe Number = 2, T = 19.978000 C 03:04:12 Temperature Measurement, Probe Number = 3, T = 19.960000 C 03:04:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:04:12 Integrated Voltage Measurement... 03:04:31 Voltage Offset Correction: v_off_ini = 0.000002477 V, v_off_fin = 0.000006818 V 03:04:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439735 Vs 03:04:31 Integrated Voltage Measurement... 03:04:51 Voltage Offset Correction: v_off_ini = 0.000006252 V, v_off_fin = -0.000000253 V 03:04:51 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175291213 Vs 03:04:54 Temperature Measurement, Probe Number = 0, T = 20.082000 C 03:04:55 Temperature Measurement, Probe Number = 1, T = 20.012000 C 03:04:55 Temperature Measurement, Probe Number = 2, T = 19.977000 C 03:04:56 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:04:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:04:56 Integrated Voltage Measurement... 03:05:16 Voltage Offset Correction: v_off_ini = 0.000002848 V, v_off_fin = 0.000006568 V 03:05:16 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175428337 Vs 03:05:16 Integrated Voltage Measurement... 03:05:36 Voltage Offset Correction: v_off_ini = 0.000005469 V, v_off_fin = -0.000001224 V 03:05:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299651 Vs 03:05:38 Temperature Measurement, Probe Number = 0, T = 20.095000 C 03:05:39 Temperature Measurement, Probe Number = 1, T = 20.011000 C 03:05:40 Temperature Measurement, Probe Number = 2, T = 19.976000 C 03:05:40 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:05:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:05:41 Integrated Voltage Measurement... 03:06:00 Voltage Offset Correction: v_off_ini = 0.000001636 V, v_off_fin = 0.000006297 V 03:06:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422142 Vs 03:06:00 Integrated Voltage Measurement... 03:06:19 Voltage Offset Correction: v_off_ini = 0.000005123 V, v_off_fin = -0.000001813 V 03:06:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301553 Vs 03:06:22 Temperature Measurement, Probe Number = 0, T = 20.085000 C 03:06:22 Temperature Measurement, Probe Number = 1, T = 20.015000 C 03:06:23 Temperature Measurement, Probe Number = 2, T = 19.982000 C 03:06:24 Temperature Measurement, Probe Number = 3, T = 19.965000 C 03:06:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:06:24 Integrated Voltage Measurement... 03:06:43 Voltage Offset Correction: v_off_ini = 0.000001650 V, v_off_fin = 0.000006676 V 03:06:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426490 Vs 03:06:43 Integrated Voltage Measurement... 03:07:02 Voltage Offset Correction: v_off_ini = 0.000005555 V, v_off_fin = -0.000001383 V 03:07:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306412 Vs 03:07:05 Temperature Measurement, Probe Number = 0, T = 20.142000 C 03:07:06 Temperature Measurement, Probe Number = 1, T = 20.015000 C 03:07:07 Temperature Measurement, Probe Number = 2, T = 19.982000 C 03:07:07 Temperature Measurement, Probe Number = 3, T = 19.967000 C 03:07:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:07:07 Integrated Voltage Measurement... 03:07:27 Voltage Offset Correction: v_off_ini = 0.000001338 V, v_off_fin = 0.000006066 V 03:07:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428912 Vs 03:07:27 Integrated Voltage Measurement... 03:07:46 Voltage Offset Correction: v_off_ini = 0.000005090 V, v_off_fin = -0.000001817 V 03:07:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304708 Vs 03:07:49 Temperature Measurement, Probe Number = 0, T = 20.149000 C 03:07:50 Temperature Measurement, Probe Number = 1, T = 20.015000 C 03:07:50 Temperature Measurement, Probe Number = 2, T = 19.980000 C 03:07:51 Temperature Measurement, Probe Number = 3, T = 19.964000 C 03:07:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 03:07:51 Integrated Voltage Measurement... 03:08:10 Voltage Offset Correction: v_off_ini = 0.000001985 V, v_off_fin = 0.000006582 V 03:08:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436158 Vs 03:08:10 Integrated Voltage Measurement... 03:08:30 Voltage Offset Correction: v_off_ini = 0.000006294 V, v_off_fin = -0.000000820 V 03:08:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293049 Vs 03:38:32 Temperature Measurement, Probe Number = 0, T = 20.257000 C 03:38:33 Temperature Measurement, Probe Number = 1, T = 20.014000 C 03:38:34 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:38:34 Temperature Measurement, Probe Number = 3, T = 19.967000 C 03:38:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:38:35 Integrated Voltage Measurement... 03:38:54 Voltage Offset Correction: v_off_ini = 0.000004530 V, v_off_fin = 0.000006864 V 03:38:54 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175530802 Vs 03:38:54 Integrated Voltage Measurement... 03:39:13 Voltage Offset Correction: v_off_ini = 0.000006089 V, v_off_fin = -0.000001174 V 03:39:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285299 Vs 03:39:16 Temperature Measurement, Probe Number = 0, T = 20.244000 C 03:39:17 Temperature Measurement, Probe Number = 1, T = 20.016000 C 03:39:18 Temperature Measurement, Probe Number = 2, T = 19.986000 C 03:39:18 Temperature Measurement, Probe Number = 3, T = 19.969000 C 03:39:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:39:18 Integrated Voltage Measurement... 03:39:38 Voltage Offset Correction: v_off_ini = 0.000002052 V, v_off_fin = 0.000006408 V 03:39:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421092 Vs 03:39:38 Integrated Voltage Measurement... 03:39:57 Voltage Offset Correction: v_off_ini = 0.000005697 V, v_off_fin = -0.000002325 V 03:39:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282500 Vs 03:40:00 Temperature Measurement, Probe Number = 0, T = 20.266000 C 03:40:01 Temperature Measurement, Probe Number = 1, T = 20.019000 C 03:40:01 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:40:02 Temperature Measurement, Probe Number = 3, T = 19.968000 C 03:40:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:40:02 Integrated Voltage Measurement... 03:40:21 Voltage Offset Correction: v_off_ini = 0.000001808 V, v_off_fin = 0.000006367 V 03:40:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424453 Vs 03:40:22 Integrated Voltage Measurement... 03:40:41 Voltage Offset Correction: v_off_ini = 0.000005793 V, v_off_fin = -0.000001680 V 03:40:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285366 Vs 03:40:44 Temperature Measurement, Probe Number = 0, T = 20.235000 C 03:40:45 Temperature Measurement, Probe Number = 1, T = 20.018000 C 03:40:45 Temperature Measurement, Probe Number = 2, T = 19.986000 C 03:40:46 Temperature Measurement, Probe Number = 3, T = 19.968000 C 03:40:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:40:46 Integrated Voltage Measurement... 03:41:05 Voltage Offset Correction: v_off_ini = 0.000002078 V, v_off_fin = 0.000006907 V 03:41:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425772 Vs 03:41:05 Integrated Voltage Measurement... 03:41:25 Voltage Offset Correction: v_off_ini = 0.000006435 V, v_off_fin = -0.000001789 V 03:41:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286658 Vs 03:41:27 Temperature Measurement, Probe Number = 0, T = 20.188000 C 03:41:28 Temperature Measurement, Probe Number = 1, T = 20.016000 C 03:41:29 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:41:29 Temperature Measurement, Probe Number = 3, T = 19.971000 C 03:41:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:41:29 Integrated Voltage Measurement... 03:41:49 Voltage Offset Correction: v_off_ini = 0.000001277 V, v_off_fin = 0.000006566 V 03:41:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418403 Vs 03:41:49 Integrated Voltage Measurement... 03:42:09 Voltage Offset Correction: v_off_ini = 0.000005772 V, v_off_fin = -0.000001392 V 03:42:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299282 Vs 03:42:12 Temperature Measurement, Probe Number = 0, T = 20.142000 C 03:42:12 Temperature Measurement, Probe Number = 1, T = 20.016000 C 03:42:13 Temperature Measurement, Probe Number = 2, T = 19.986000 C 03:42:13 Temperature Measurement, Probe Number = 3, T = 19.971000 C 03:42:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:42:14 Integrated Voltage Measurement... 03:42:33 Voltage Offset Correction: v_off_ini = 0.000002158 V, v_off_fin = 0.000007539 V 03:42:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422624 Vs 03:42:33 Integrated Voltage Measurement... 03:42:52 Voltage Offset Correction: v_off_ini = 0.000006315 V, v_off_fin = -0.000001610 V 03:42:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284332 Vs 03:42:55 Temperature Measurement, Probe Number = 0, T = 20.094000 C 03:42:56 Temperature Measurement, Probe Number = 1, T = 20.017000 C 03:42:56 Temperature Measurement, Probe Number = 2, T = 19.984000 C 03:42:57 Temperature Measurement, Probe Number = 3, T = 19.969000 C 03:42:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:42:57 Integrated Voltage Measurement... 03:43:16 Voltage Offset Correction: v_off_ini = 0.000002331 V, v_off_fin = 0.000006580 V 03:43:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424887 Vs 03:43:16 Integrated Voltage Measurement... 03:43:36 Voltage Offset Correction: v_off_ini = 0.000005914 V, v_off_fin = -0.000002212 V 03:43:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291656 Vs 03:43:39 Temperature Measurement, Probe Number = 0, T = 20.079000 C 03:43:39 Temperature Measurement, Probe Number = 1, T = 20.018000 C 03:43:40 Temperature Measurement, Probe Number = 2, T = 19.986000 C 03:43:40 Temperature Measurement, Probe Number = 3, T = 19.968000 C 03:43:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:43:41 Integrated Voltage Measurement... 03:44:00 Voltage Offset Correction: v_off_ini = 0.000002460 V, v_off_fin = 0.000005913 V 03:44:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419585 Vs 03:44:00 Integrated Voltage Measurement... 03:44:20 Voltage Offset Correction: v_off_ini = 0.000005238 V, v_off_fin = -0.000002025 V 03:44:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299800 Vs 03:44:23 Temperature Measurement, Probe Number = 0, T = 20.086000 C 03:44:23 Temperature Measurement, Probe Number = 1, T = 20.015000 C 03:44:24 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:44:25 Temperature Measurement, Probe Number = 3, T = 19.969000 C 03:44:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 03:44:25 Integrated Voltage Measurement... 03:44:44 Voltage Offset Correction: v_off_ini = 0.000001295 V, v_off_fin = 0.000006643 V 03:44:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417245 Vs 03:44:45 Integrated Voltage Measurement... 03:45:04 Voltage Offset Correction: v_off_ini = 0.000005630 V, v_off_fin = -0.000001805 V 03:45:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288653 Vs 03:45:07 Temperature Measurement, Probe Number = 0, T = 20.119000 C 03:45:07 Temperature Measurement, Probe Number = 1, T = 20.016000 C 03:45:08 Temperature Measurement, Probe Number = 2, T = 19.987000 C 03:45:09 Temperature Measurement, Probe Number = 3, T = 19.968000 C 03:45:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 03:45:09 Integrated Voltage Measurement... 03:45:28 Voltage Offset Correction: v_off_ini = 0.000001988 V, v_off_fin = 0.000005793 V 03:45:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417043 Vs 03:45:28 Integrated Voltage Measurement... 03:45:47 Voltage Offset Correction: v_off_ini = 0.000005736 V, v_off_fin = -0.000001591 V 03:45:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282553 Vs 04:15:50 Temperature Measurement, Probe Number = 0, T = 20.174000 C 04:15:51 Temperature Measurement, Probe Number = 1, T = 20.013000 C 04:15:52 Temperature Measurement, Probe Number = 2, T = 19.982000 C 04:15:52 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:15:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:15:52 Integrated Voltage Measurement... 04:16:12 Voltage Offset Correction: v_off_ini = 0.000004616 V, v_off_fin = 0.000006754 V 04:16:12 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175526127 Vs 04:16:12 Integrated Voltage Measurement... 04:16:31 Voltage Offset Correction: v_off_ini = 0.000005979 V, v_off_fin = -0.000001135 V 04:16:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282089 Vs 04:16:34 Temperature Measurement, Probe Number = 0, T = 20.213000 C 04:16:35 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:16:36 Temperature Measurement, Probe Number = 2, T = 19.982000 C 04:16:36 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:16:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:16:36 Integrated Voltage Measurement... 04:16:56 Voltage Offset Correction: v_off_ini = 0.000001625 V, v_off_fin = 0.000006668 V 04:16:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422042 Vs 04:16:57 Integrated Voltage Measurement... 04:17:16 Voltage Offset Correction: v_off_ini = 0.000005722 V, v_off_fin = -0.000001709 V 04:17:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175289534 Vs 04:17:19 Temperature Measurement, Probe Number = 0, T = 20.178000 C 04:17:19 Temperature Measurement, Probe Number = 1, T = 20.013000 C 04:17:20 Temperature Measurement, Probe Number = 2, T = 19.982000 C 04:17:21 Temperature Measurement, Probe Number = 3, T = 19.964000 C 04:17:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 04:17:21 Integrated Voltage Measurement... 04:17:41 Voltage Offset Correction: v_off_ini = 0.000002653 V, v_off_fin = 0.000007075 V 04:17:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425404 Vs 04:17:41 Integrated Voltage Measurement... 04:18:00 Voltage Offset Correction: v_off_ini = 0.000005923 V, v_off_fin = -0.000001590 V 04:18:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175280452 Vs 04:18:03 Temperature Measurement, Probe Number = 0, T = 20.132000 C 04:18:04 Temperature Measurement, Probe Number = 1, T = 20.014000 C 04:18:04 Temperature Measurement, Probe Number = 2, T = 19.984000 C 04:18:05 Temperature Measurement, Probe Number = 3, T = 19.965000 C 04:18:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 04:18:05 Integrated Voltage Measurement... 04:18:24 Voltage Offset Correction: v_off_ini = 0.000002050 V, v_off_fin = 0.000007181 V 04:18:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424459 Vs 04:18:25 Integrated Voltage Measurement... 04:18:43 Voltage Offset Correction: v_off_ini = 0.000006266 V, v_off_fin = -0.000001681 V 04:18:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283762 Vs 04:18:46 Temperature Measurement, Probe Number = 0, T = 20.179000 C 04:18:47 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:18:48 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:18:48 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:18:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:18:48 Integrated Voltage Measurement... 04:19:07 Voltage Offset Correction: v_off_ini = 0.000001606 V, v_off_fin = 0.000007440 V 04:19:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422433 Vs 04:19:08 Integrated Voltage Measurement... 04:19:27 Voltage Offset Correction: v_off_ini = 0.000006214 V, v_off_fin = -0.000001460 V 04:19:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290563 Vs 04:19:30 Temperature Measurement, Probe Number = 0, T = 20.196000 C 04:19:31 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:19:31 Temperature Measurement, Probe Number = 2, T = 19.984000 C 04:19:32 Temperature Measurement, Probe Number = 3, T = 19.965000 C 04:19:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 04:19:32 Integrated Voltage Measurement... 04:19:51 Voltage Offset Correction: v_off_ini = 0.000001994 V, v_off_fin = 0.000006828 V 04:19:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421838 Vs 04:19:52 Integrated Voltage Measurement... 04:20:11 Voltage Offset Correction: v_off_ini = 0.000005798 V, v_off_fin = -0.000001808 V 04:20:11 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175292869 Vs 04:20:14 Temperature Measurement, Probe Number = 0, T = 20.139000 C 04:20:15 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:20:15 Temperature Measurement, Probe Number = 2, T = 19.979000 C 04:20:16 Temperature Measurement, Probe Number = 3, T = 19.963000 C 04:20:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 04:20:16 Integrated Voltage Measurement... 04:20:35 Voltage Offset Correction: v_off_ini = 0.000001652 V, v_off_fin = 0.000006903 V 04:20:36 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175413990 Vs 04:20:36 Integrated Voltage Measurement... 04:20:55 Voltage Offset Correction: v_off_ini = 0.000006313 V, v_off_fin = -0.000000577 V 04:20:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175278077 Vs 04:20:58 Temperature Measurement, Probe Number = 0, T = 20.159000 C 04:20:58 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:20:59 Temperature Measurement, Probe Number = 2, T = 19.984000 C 04:20:59 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:21:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:21:00 Integrated Voltage Measurement... 04:21:19 Voltage Offset Correction: v_off_ini = 0.000002109 V, v_off_fin = 0.000006643 V 04:21:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418709 Vs 04:21:19 Integrated Voltage Measurement... 04:21:38 Voltage Offset Correction: v_off_ini = 0.000005934 V, v_off_fin = -0.000001629 V 04:21:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280108 Vs 04:21:41 Temperature Measurement, Probe Number = 0, T = 20.204000 C 04:21:41 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:21:42 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:21:43 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:21:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:21:43 Integrated Voltage Measurement... 04:22:02 Voltage Offset Correction: v_off_ini = 0.000002072 V, v_off_fin = 0.000007206 V 04:22:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425503 Vs 04:22:02 Integrated Voltage Measurement... 04:22:21 Voltage Offset Correction: v_off_ini = 0.000006602 V, v_off_fin = -0.000000845 V 04:22:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287394 Vs 04:22:24 Temperature Measurement, Probe Number = 0, T = 20.258000 C 04:22:25 Temperature Measurement, Probe Number = 1, T = 20.020000 C 04:22:26 Temperature Measurement, Probe Number = 2, T = 19.986000 C 04:22:26 Temperature Measurement, Probe Number = 3, T = 19.967000 C 04:22:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:22:26 Integrated Voltage Measurement... 04:22:46 Voltage Offset Correction: v_off_ini = 0.000002933 V, v_off_fin = 0.000007609 V 04:22:46 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175434197 Vs 04:22:46 Integrated Voltage Measurement... 04:23:05 Voltage Offset Correction: v_off_ini = 0.000006781 V, v_off_fin = -0.000001471 V 04:23:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282446 Vs 04:53:08 Temperature Measurement, Probe Number = 0, T = 20.266000 C 04:53:09 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:53:09 Temperature Measurement, Probe Number = 2, T = 19.987000 C 04:53:10 Temperature Measurement, Probe Number = 3, T = 19.967000 C 04:53:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:53:10 Integrated Voltage Measurement... 04:53:30 Voltage Offset Correction: v_off_ini = 0.000004382 V, v_off_fin = 0.000006854 V 04:53:30 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175517634 Vs 04:53:30 Integrated Voltage Measurement... 04:53:49 Voltage Offset Correction: v_off_ini = 0.000005767 V, v_off_fin = -0.000000999 V 04:53:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292406 Vs 04:53:52 Temperature Measurement, Probe Number = 0, T = 20.262000 C 04:53:53 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:53:54 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:53:54 Temperature Measurement, Probe Number = 3, T = 19.968000 C 04:53:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:53:54 Integrated Voltage Measurement... 04:54:14 Voltage Offset Correction: v_off_ini = 0.000002641 V, v_off_fin = 0.000007162 V 04:54:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175420710 Vs 04:54:14 Integrated Voltage Measurement... 04:54:33 Voltage Offset Correction: v_off_ini = 0.000006178 V, v_off_fin = -0.000001664 V 04:54:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293957 Vs 04:54:36 Temperature Measurement, Probe Number = 0, T = 20.216000 C 04:54:37 Temperature Measurement, Probe Number = 1, T = 20.019000 C 04:54:37 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:54:38 Temperature Measurement, Probe Number = 3, T = 19.967000 C 04:54:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:54:38 Integrated Voltage Measurement... 04:54:58 Voltage Offset Correction: v_off_ini = 0.000002030 V, v_off_fin = 0.000006929 V 04:54:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423925 Vs 04:54:58 Integrated Voltage Measurement... 04:55:18 Voltage Offset Correction: v_off_ini = 0.000005762 V, v_off_fin = -0.000001102 V 04:55:18 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175282396 Vs 04:55:20 Temperature Measurement, Probe Number = 0, T = 20.251000 C 04:55:21 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:55:22 Temperature Measurement, Probe Number = 2, T = 19.984000 C 04:55:22 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:55:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:55:23 Integrated Voltage Measurement... 04:55:42 Voltage Offset Correction: v_off_ini = 0.000002583 V, v_off_fin = 0.000007140 V 04:55:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425562 Vs 04:55:42 Integrated Voltage Measurement... 04:56:01 Voltage Offset Correction: v_off_ini = 0.000006209 V, v_off_fin = -0.000001221 V 04:56:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293692 Vs 04:56:04 Temperature Measurement, Probe Number = 0, T = 20.238000 C 04:56:05 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:56:06 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:56:06 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:56:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:56:06 Integrated Voltage Measurement... 04:56:26 Voltage Offset Correction: v_off_ini = 0.000002077 V, v_off_fin = 0.000007006 V 04:56:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429610 Vs 04:56:26 Integrated Voltage Measurement... 04:56:46 Voltage Offset Correction: v_off_ini = 0.000006124 V, v_off_fin = -0.000001425 V 04:56:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175287080 Vs 04:56:48 Temperature Measurement, Probe Number = 0, T = 20.262000 C 04:56:49 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:56:50 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:56:50 Temperature Measurement, Probe Number = 3, T = 19.965000 C 04:56:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 04:56:50 Integrated Voltage Measurement... 04:57:09 Voltage Offset Correction: v_off_ini = 0.000002447 V, v_off_fin = 0.000007099 V 04:57:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424418 Vs 04:57:10 Integrated Voltage Measurement... 04:57:29 Voltage Offset Correction: v_off_ini = 0.000006164 V, v_off_fin = -0.000001070 V 04:57:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286366 Vs 04:57:32 Temperature Measurement, Probe Number = 0, T = 20.208000 C 04:57:32 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:57:33 Temperature Measurement, Probe Number = 2, T = 19.989000 C 04:57:33 Temperature Measurement, Probe Number = 3, T = 19.970000 C 04:57:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:57:34 Integrated Voltage Measurement... 04:57:54 Voltage Offset Correction: v_off_ini = 0.000002375 V, v_off_fin = 0.000006896 V 04:57:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431018 Vs 04:57:54 Integrated Voltage Measurement... 04:58:13 Voltage Offset Correction: v_off_ini = 0.000005878 V, v_off_fin = -0.000001648 V 04:58:13 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175281680 Vs 04:58:16 Temperature Measurement, Probe Number = 0, T = 20.181000 C 04:58:16 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:58:17 Temperature Measurement, Probe Number = 2, T = 19.989000 C 04:58:18 Temperature Measurement, Probe Number = 3, T = 19.966000 C 04:58:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:58:18 Integrated Voltage Measurement... 04:58:37 Voltage Offset Correction: v_off_ini = 0.000001877 V, v_off_fin = 0.000006877 V 04:58:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424370 Vs 04:58:37 Integrated Voltage Measurement... 04:58:57 Voltage Offset Correction: v_off_ini = 0.000006148 V, v_off_fin = -0.000000730 V 04:58:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291183 Vs 04:59:00 Temperature Measurement, Probe Number = 0, T = 20.185000 C 04:59:00 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:59:01 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:59:02 Temperature Measurement, Probe Number = 3, T = 19.965000 C 04:59:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 04:59:02 Integrated Voltage Measurement... 04:59:21 Voltage Offset Correction: v_off_ini = 0.000002843 V, v_off_fin = 0.000006888 V 04:59:21 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429042 Vs 04:59:21 Integrated Voltage Measurement... 04:59:40 Voltage Offset Correction: v_off_ini = 0.000005818 V, v_off_fin = -0.000001375 V 04:59:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292417 Vs 04:59:43 Temperature Measurement, Probe Number = 0, T = 20.165000 C 04:59:44 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:59:44 Temperature Measurement, Probe Number = 2, T = 19.986000 C 04:59:45 Temperature Measurement, Probe Number = 3, T = 19.967000 C 04:59:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 04:59:45 Integrated Voltage Measurement... 05:00:04 Voltage Offset Correction: v_off_ini = 0.000002235 V, v_off_fin = 0.000006737 V 05:00:04 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428211 Vs 05:00:04 Integrated Voltage Measurement... 05:00:24 Voltage Offset Correction: v_off_ini = 0.000005867 V, v_off_fin = -0.000002462 V 05:00:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292554 Vs 05:30:27 Temperature Measurement, Probe Number = 0, T = 20.163000 C 05:30:27 Temperature Measurement, Probe Number = 1, T = 20.010000 C 05:30:28 Temperature Measurement, Probe Number = 2, T = 19.976000 C 05:30:28 Temperature Measurement, Probe Number = 3, T = 19.961000 C 05:30:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 05:30:29 Integrated Voltage Measurement... 05:30:48 Voltage Offset Correction: v_off_ini = 0.000005138 V, v_off_fin = 0.000007422 V 05:30:48 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175524245 Vs 05:30:48 Integrated Voltage Measurement... 05:31:08 Voltage Offset Correction: v_off_ini = 0.000006375 V, v_off_fin = -0.000000628 V 05:31:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285355 Vs 05:31:11 Temperature Measurement, Probe Number = 0, T = 20.121000 C 05:31:11 Temperature Measurement, Probe Number = 1, T = 20.013000 C 05:31:12 Temperature Measurement, Probe Number = 2, T = 19.983000 C 05:31:13 Temperature Measurement, Probe Number = 3, T = 19.963000 C 05:31:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 05:31:13 Integrated Voltage Measurement... 05:31:32 Voltage Offset Correction: v_off_ini = 0.000002794 V, v_off_fin = 0.000007056 V 05:31:32 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432507 Vs 05:31:32 Integrated Voltage Measurement... 05:31:52 Voltage Offset Correction: v_off_ini = 0.000006218 V, v_off_fin = -0.000000855 V 05:31:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290845 Vs 05:31:54 Temperature Measurement, Probe Number = 0, T = 20.149000 C 05:31:55 Temperature Measurement, Probe Number = 1, T = 20.015000 C 05:31:56 Temperature Measurement, Probe Number = 2, T = 19.985000 C 05:31:56 Temperature Measurement, Probe Number = 3, T = 19.963000 C 05:31:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 05:31:57 Integrated Voltage Measurement... 05:32:16 Voltage Offset Correction: v_off_ini = 0.000002530 V, v_off_fin = 0.000006260 V 05:32:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429200 Vs 05:32:16 Integrated Voltage Measurement... 05:32:36 Voltage Offset Correction: v_off_ini = 0.000005861 V, v_off_fin = -0.000001474 V 05:32:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298767 Vs 05:32:39 Temperature Measurement, Probe Number = 0, T = 20.133000 C 05:32:39 Temperature Measurement, Probe Number = 1, T = 20.014000 C 05:32:40 Temperature Measurement, Probe Number = 2, T = 19.984000 C 05:32:41 Temperature Measurement, Probe Number = 3, T = 19.966000 C 05:32:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:32:41 Integrated Voltage Measurement... 05:33:00 Voltage Offset Correction: v_off_ini = 0.000001915 V, v_off_fin = 0.000007526 V 05:33:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429317 Vs 05:33:00 Integrated Voltage Measurement... 05:33:19 Voltage Offset Correction: v_off_ini = 0.000006657 V, v_off_fin = -0.000001497 V 05:33:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281491 Vs 05:33:22 Temperature Measurement, Probe Number = 0, T = 20.086000 C 05:33:23 Temperature Measurement, Probe Number = 1, T = 20.017000 C 05:33:24 Temperature Measurement, Probe Number = 2, T = 19.985000 C 05:33:24 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:33:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:33:24 Integrated Voltage Measurement... 05:33:43 Voltage Offset Correction: v_off_ini = 0.000002229 V, v_off_fin = 0.000006704 V 05:33:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429518 Vs 05:33:44 Integrated Voltage Measurement... 05:34:03 Voltage Offset Correction: v_off_ini = 0.000006435 V, v_off_fin = -0.000000953 V 05:34:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286614 Vs 05:34:06 Temperature Measurement, Probe Number = 0, T = 20.101000 C 05:34:07 Temperature Measurement, Probe Number = 1, T = 20.016000 C 05:34:07 Temperature Measurement, Probe Number = 2, T = 19.984000 C 05:34:08 Temperature Measurement, Probe Number = 3, T = 19.964000 C 05:34:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 05:34:08 Integrated Voltage Measurement... 05:34:27 Voltage Offset Correction: v_off_ini = 0.000002404 V, v_off_fin = 0.000007377 V 05:34:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424689 Vs 05:34:28 Integrated Voltage Measurement... 05:34:47 Voltage Offset Correction: v_off_ini = 0.000006354 V, v_off_fin = -0.000001961 V 05:34:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291023 Vs 05:34:50 Temperature Measurement, Probe Number = 0, T = 20.089000 C 05:34:50 Temperature Measurement, Probe Number = 1, T = 20.016000 C 05:34:51 Temperature Measurement, Probe Number = 2, T = 19.983000 C 05:34:51 Temperature Measurement, Probe Number = 3, T = 19.964000 C 05:34:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 05:34:52 Integrated Voltage Measurement... 05:35:11 Voltage Offset Correction: v_off_ini = 0.000002494 V, v_off_fin = 0.000007374 V 05:35:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437364 Vs 05:35:11 Integrated Voltage Measurement... 05:35:30 Voltage Offset Correction: v_off_ini = 0.000006583 V, v_off_fin = -0.000001537 V 05:35:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285204 Vs 05:35:33 Temperature Measurement, Probe Number = 0, T = 20.138000 C 05:35:34 Temperature Measurement, Probe Number = 1, T = 20.019000 C 05:35:34 Temperature Measurement, Probe Number = 2, T = 19.987000 C 05:35:35 Temperature Measurement, Probe Number = 3, T = 19.965000 C 05:35:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 05:35:35 Integrated Voltage Measurement... 05:35:54 Voltage Offset Correction: v_off_ini = 0.000002522 V, v_off_fin = 0.000006784 V 05:35:55 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428581 Vs 05:35:55 Integrated Voltage Measurement... 05:36:14 Voltage Offset Correction: v_off_ini = 0.000005894 V, v_off_fin = -0.000000914 V 05:36:15 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175290667 Vs 05:36:17 Temperature Measurement, Probe Number = 0, T = 20.194000 C 05:36:18 Temperature Measurement, Probe Number = 1, T = 20.017000 C 05:36:18 Temperature Measurement, Probe Number = 2, T = 19.986000 C 05:36:19 Temperature Measurement, Probe Number = 3, T = 19.965000 C 05:36:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 05:36:19 Integrated Voltage Measurement... 05:36:38 Voltage Offset Correction: v_off_ini = 0.000002606 V, v_off_fin = 0.000006901 V 05:36:38 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417780 Vs 05:36:38 Integrated Voltage Measurement... 05:36:59 Voltage Offset Correction: v_off_ini = 0.000006038 V, v_off_fin = 0.000000002 V 05:36:59 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175292155 Vs 05:37:02 Temperature Measurement, Probe Number = 0, T = 20.153000 C 05:37:03 Temperature Measurement, Probe Number = 1, T = 20.014000 C 05:37:03 Temperature Measurement, Probe Number = 2, T = 19.986000 C 05:37:04 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:37:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 05:37:04 Integrated Voltage Measurement... 05:37:23 Voltage Offset Correction: v_off_ini = 0.000002729 V, v_off_fin = 0.000006874 V 05:37:23 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175415884 Vs 05:37:24 Integrated Voltage Measurement... 05:37:43 Voltage Offset Correction: v_off_ini = 0.000006540 V, v_off_fin = -0.000001304 V 05:37:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282815 Vs 06:07:46 Temperature Measurement, Probe Number = 0, T = 20.221000 C 06:07:46 Temperature Measurement, Probe Number = 1, T = 20.014000 C 06:07:47 Temperature Measurement, Probe Number = 2, T = 19.983000 C 06:07:47 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:07:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 06:07:48 Integrated Voltage Measurement... 06:08:07 Voltage Offset Correction: v_off_ini = 0.000004854 V, v_off_fin = 0.000006909 V 06:08:07 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175528867 Vs 06:08:07 Integrated Voltage Measurement... 06:08:26 Voltage Offset Correction: v_off_ini = 0.000005993 V, v_off_fin = -0.000001043 V 06:08:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285731 Vs 06:08:29 Temperature Measurement, Probe Number = 0, T = 20.193000 C 06:08:30 Temperature Measurement, Probe Number = 1, T = 20.015000 C 06:08:31 Temperature Measurement, Probe Number = 2, T = 19.985000 C 06:08:31 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:08:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 06:08:31 Integrated Voltage Measurement... 06:08:50 Voltage Offset Correction: v_off_ini = 0.000002163 V, v_off_fin = 0.000006479 V 06:08:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428533 Vs 06:08:51 Integrated Voltage Measurement... 06:09:10 Voltage Offset Correction: v_off_ini = 0.000006166 V, v_off_fin = -0.000001690 V 06:09:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286052 Vs 06:09:12 Temperature Measurement, Probe Number = 0, T = 20.218000 C 06:09:13 Temperature Measurement, Probe Number = 1, T = 20.015000 C 06:09:14 Temperature Measurement, Probe Number = 2, T = 19.986000 C 06:09:14 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:09:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:09:15 Integrated Voltage Measurement... 06:09:34 Voltage Offset Correction: v_off_ini = 0.000002208 V, v_off_fin = 0.000006911 V 06:09:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428824 Vs 06:09:34 Integrated Voltage Measurement... 06:09:53 Voltage Offset Correction: v_off_ini = 0.000006160 V, v_off_fin = -0.000000560 V 06:09:54 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175282916 Vs 06:09:56 Temperature Measurement, Probe Number = 0, T = 20.238000 C 06:09:57 Temperature Measurement, Probe Number = 1, T = 20.012000 C 06:09:58 Temperature Measurement, Probe Number = 2, T = 19.987000 C 06:09:58 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:09:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:09:58 Integrated Voltage Measurement... 06:10:18 Voltage Offset Correction: v_off_ini = 0.000002015 V, v_off_fin = 0.000007016 V 06:10:18 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175414995 Vs 06:10:18 Integrated Voltage Measurement... 06:10:37 Voltage Offset Correction: v_off_ini = 0.000006478 V, v_off_fin = -0.000001725 V 06:10:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285488 Vs 06:10:40 Temperature Measurement, Probe Number = 0, T = 20.215000 C 06:10:40 Temperature Measurement, Probe Number = 1, T = 20.015000 C 06:10:41 Temperature Measurement, Probe Number = 2, T = 19.985000 C 06:10:41 Temperature Measurement, Probe Number = 3, T = 19.964000 C 06:10:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:10:42 Integrated Voltage Measurement... 06:11:01 Voltage Offset Correction: v_off_ini = 0.000001858 V, v_off_fin = 0.000006520 V 06:11:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423007 Vs 06:11:01 Integrated Voltage Measurement... 06:11:20 Voltage Offset Correction: v_off_ini = 0.000005906 V, v_off_fin = -0.000001655 V 06:11:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291786 Vs 06:11:23 Temperature Measurement, Probe Number = 0, T = 20.242000 C 06:11:24 Temperature Measurement, Probe Number = 1, T = 20.016000 C 06:11:25 Temperature Measurement, Probe Number = 2, T = 19.988000 C 06:11:25 Temperature Measurement, Probe Number = 3, T = 19.968000 C 06:11:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:11:25 Integrated Voltage Measurement... 06:11:45 Voltage Offset Correction: v_off_ini = 0.000002037 V, v_off_fin = 0.000006386 V 06:11:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423801 Vs 06:11:45 Integrated Voltage Measurement... 06:12:04 Voltage Offset Correction: v_off_ini = 0.000005449 V, v_off_fin = -0.000000918 V 06:12:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291017 Vs 06:12:07 Temperature Measurement, Probe Number = 0, T = 20.229000 C 06:12:08 Temperature Measurement, Probe Number = 1, T = 20.017000 C 06:12:08 Temperature Measurement, Probe Number = 2, T = 19.986000 C 06:12:09 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:12:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:12:09 Integrated Voltage Measurement... 06:12:28 Voltage Offset Correction: v_off_ini = 0.000001661 V, v_off_fin = 0.000007127 V 06:12:29 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433111 Vs 06:12:29 Integrated Voltage Measurement... 06:12:48 Voltage Offset Correction: v_off_ini = 0.000005938 V, v_off_fin = -0.000001522 V 06:12:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290135 Vs 06:12:51 Temperature Measurement, Probe Number = 0, T = 20.268000 C 06:12:51 Temperature Measurement, Probe Number = 1, T = 20.016000 C 06:12:52 Temperature Measurement, Probe Number = 2, T = 19.987000 C 06:12:53 Temperature Measurement, Probe Number = 3, T = 19.968000 C 06:12:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:12:53 Integrated Voltage Measurement... 06:13:12 Voltage Offset Correction: v_off_ini = 0.000001972 V, v_off_fin = 0.000006729 V 06:13:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426079 Vs 06:13:12 Integrated Voltage Measurement... 06:13:32 Voltage Offset Correction: v_off_ini = 0.000005657 V, v_off_fin = -0.000001472 V 06:13:32 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175298955 Vs 06:13:35 Temperature Measurement, Probe Number = 0, T = 20.330000 C 06:13:35 Temperature Measurement, Probe Number = 1, T = 20.020000 C 06:13:36 Temperature Measurement, Probe Number = 2, T = 19.989000 C 06:13:37 Temperature Measurement, Probe Number = 3, T = 19.970000 C 06:13:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:13:37 Integrated Voltage Measurement... 06:13:56 Voltage Offset Correction: v_off_ini = 0.000001580 V, v_off_fin = 0.000006548 V 06:13:56 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175416688 Vs 06:13:56 Integrated Voltage Measurement... 06:14:15 Voltage Offset Correction: v_off_ini = 0.000005716 V, v_off_fin = -0.000001198 V 06:14:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288506 Vs 06:14:18 Temperature Measurement, Probe Number = 0, T = 20.321000 C 06:14:19 Temperature Measurement, Probe Number = 1, T = 20.018000 C 06:14:19 Temperature Measurement, Probe Number = 2, T = 19.988000 C 06:14:20 Temperature Measurement, Probe Number = 3, T = 19.966000 C 06:14:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:14:20 Integrated Voltage Measurement... 06:14:39 Voltage Offset Correction: v_off_ini = 0.000001880 V, v_off_fin = 0.000006751 V 06:14:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427578 Vs 06:14:39 Integrated Voltage Measurement... 06:14:59 Voltage Offset Correction: v_off_ini = 0.000005675 V, v_off_fin = -0.000001498 V 06:14:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294149 Vs 06:45:01 Temperature Measurement, Probe Number = 0, T = 20.264000 C 06:45:02 Temperature Measurement, Probe Number = 1, T = 20.012000 C 06:45:03 Temperature Measurement, Probe Number = 2, T = 19.985000 C 06:45:03 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:45:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:45:04 Integrated Voltage Measurement... 06:45:23 Voltage Offset Correction: v_off_ini = 0.000004350 V, v_off_fin = 0.000007030 V 06:45:23 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175514800 Vs 06:45:23 Integrated Voltage Measurement... 06:45:42 Voltage Offset Correction: v_off_ini = 0.000006070 V, v_off_fin = -0.000001560 V 06:45:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287500 Vs 06:45:45 Temperature Measurement, Probe Number = 0, T = 20.230000 C 06:45:46 Temperature Measurement, Probe Number = 1, T = 20.017000 C 06:45:47 Temperature Measurement, Probe Number = 2, T = 19.986000 C 06:45:47 Temperature Measurement, Probe Number = 3, T = 19.964000 C 06:45:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:45:47 Integrated Voltage Measurement... 06:46:07 Voltage Offset Correction: v_off_ini = 0.000002518 V, v_off_fin = 0.000006482 V 06:46:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427057 Vs 06:46:07 Integrated Voltage Measurement... 06:46:26 Voltage Offset Correction: v_off_ini = 0.000006081 V, v_off_fin = -0.000001771 V 06:46:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291621 Vs 06:46:29 Temperature Measurement, Probe Number = 0, T = 20.221000 C 06:46:29 Temperature Measurement, Probe Number = 1, T = 20.018000 C 06:46:30 Temperature Measurement, Probe Number = 2, T = 19.986000 C 06:46:31 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:46:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:46:31 Integrated Voltage Measurement... 06:46:50 Voltage Offset Correction: v_off_ini = 0.000001686 V, v_off_fin = 0.000006718 V 06:46:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422655 Vs 06:46:50 Integrated Voltage Measurement... 06:47:09 Voltage Offset Correction: v_off_ini = 0.000006397 V, v_off_fin = -0.000001729 V 06:47:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282509 Vs 06:47:12 Temperature Measurement, Probe Number = 0, T = 20.212000 C 06:47:13 Temperature Measurement, Probe Number = 1, T = 20.013000 C 06:47:13 Temperature Measurement, Probe Number = 2, T = 19.983000 C 06:47:14 Temperature Measurement, Probe Number = 3, T = 19.960000 C 06:47:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:47:14 Integrated Voltage Measurement... 06:47:34 Voltage Offset Correction: v_off_ini = 0.000002829 V, v_off_fin = 0.000006597 V 06:47:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425058 Vs 06:47:34 Integrated Voltage Measurement... 06:47:54 Voltage Offset Correction: v_off_ini = 0.000005650 V, v_off_fin = -0.000000832 V 06:47:54 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175295953 Vs 06:47:56 Temperature Measurement, Probe Number = 0, T = 20.161000 C 06:47:57 Temperature Measurement, Probe Number = 1, T = 20.015000 C 06:47:58 Temperature Measurement, Probe Number = 2, T = 19.983000 C 06:47:58 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:47:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:47:59 Integrated Voltage Measurement... 06:48:18 Voltage Offset Correction: v_off_ini = 0.000001986 V, v_off_fin = 0.000006890 V 06:48:18 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429585 Vs 06:48:18 Integrated Voltage Measurement... 06:48:38 Voltage Offset Correction: v_off_ini = 0.000005932 V, v_off_fin = -0.000000687 V 06:48:38 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293249 Vs 06:48:41 Temperature Measurement, Probe Number = 0, T = 20.188000 C 06:48:41 Temperature Measurement, Probe Number = 1, T = 20.014000 C 06:48:42 Temperature Measurement, Probe Number = 2, T = 19.986000 C 06:48:43 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:48:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:48:43 Integrated Voltage Measurement... 06:49:02 Voltage Offset Correction: v_off_ini = 0.000002224 V, v_off_fin = 0.000007216 V 06:49:02 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427271 Vs 06:49:03 Integrated Voltage Measurement... 06:49:22 Voltage Offset Correction: v_off_ini = 0.000006369 V, v_off_fin = -0.000000218 V 06:49:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284127 Vs 06:49:25 Temperature Measurement, Probe Number = 0, T = 20.223000 C 06:49:25 Temperature Measurement, Probe Number = 1, T = 20.013000 C 06:49:26 Temperature Measurement, Probe Number = 2, T = 19.984000 C 06:49:27 Temperature Measurement, Probe Number = 3, T = 19.960000 C 06:49:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:49:27 Integrated Voltage Measurement... 06:49:46 Voltage Offset Correction: v_off_ini = 0.000002631 V, v_off_fin = 0.000007278 V 06:49:46 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438154 Vs 06:49:47 Integrated Voltage Measurement... 06:50:06 Voltage Offset Correction: v_off_ini = 0.000006383 V, v_off_fin = -0.000001835 V 06:50:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297992 Vs 06:50:09 Temperature Measurement, Probe Number = 0, T = 20.226000 C 06:50:10 Temperature Measurement, Probe Number = 1, T = 20.013000 C 06:50:10 Temperature Measurement, Probe Number = 2, T = 19.988000 C 06:50:11 Temperature Measurement, Probe Number = 3, T = 19.961000 C 06:50:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:50:11 Integrated Voltage Measurement... 06:50:30 Voltage Offset Correction: v_off_ini = 0.000001553 V, v_off_fin = 0.000006369 V 06:50:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435648 Vs 06:50:31 Integrated Voltage Measurement... 06:50:50 Voltage Offset Correction: v_off_ini = 0.000005719 V, v_off_fin = -0.000001614 V 06:50:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294989 Vs 06:50:53 Temperature Measurement, Probe Number = 0, T = 20.305000 C 06:50:54 Temperature Measurement, Probe Number = 1, T = 20.016000 C 06:50:54 Temperature Measurement, Probe Number = 2, T = 19.988000 C 06:50:55 Temperature Measurement, Probe Number = 3, T = 19.966000 C 06:50:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 06:50:55 Integrated Voltage Measurement... 06:51:14 Voltage Offset Correction: v_off_ini = 0.000002533 V, v_off_fin = 0.000007517 V 06:51:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432643 Vs 06:51:15 Integrated Voltage Measurement... 06:51:34 Voltage Offset Correction: v_off_ini = 0.000006500 V, v_off_fin = -0.000000267 V 06:51:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287801 Vs 06:51:37 Temperature Measurement, Probe Number = 0, T = 20.257000 C 06:51:38 Temperature Measurement, Probe Number = 1, T = 20.015000 C 06:51:38 Temperature Measurement, Probe Number = 2, T = 19.988000 C 06:51:39 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:51:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 06:51:39 Integrated Voltage Measurement... 06:51:59 Voltage Offset Correction: v_off_ini = 0.000002937 V, v_off_fin = 0.000007356 V 06:51:59 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438559 Vs 06:51:59 Integrated Voltage Measurement... 06:52:18 Voltage Offset Correction: v_off_ini = 0.000006878 V, v_off_fin = -0.000000718 V 06:52:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175277669 Vs 07:22:21 Temperature Measurement, Probe Number = 0, T = 20.343000 C 07:22:22 Temperature Measurement, Probe Number = 1, T = 20.015000 C 07:22:23 Temperature Measurement, Probe Number = 2, T = 19.989000 C 07:22:23 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:22:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 07:22:23 Integrated Voltage Measurement... 07:22:43 Voltage Offset Correction: v_off_ini = 0.000003830 V, v_off_fin = 0.000006699 V 07:22:43 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175524483 Vs 07:22:43 Integrated Voltage Measurement... 07:23:02 Voltage Offset Correction: v_off_ini = 0.000005642 V, v_off_fin = -0.000000990 V 07:23:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285991 Vs 07:23:05 Temperature Measurement, Probe Number = 0, T = 20.349000 C 07:23:06 Temperature Measurement, Probe Number = 1, T = 20.018000 C 07:23:07 Temperature Measurement, Probe Number = 2, T = 19.991000 C 07:23:07 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:23:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 07:23:07 Integrated Voltage Measurement... 07:23:26 Voltage Offset Correction: v_off_ini = 0.000001149 V, v_off_fin = 0.000006971 V 07:23:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428238 Vs 07:23:27 Integrated Voltage Measurement... 07:23:46 Voltage Offset Correction: v_off_ini = 0.000006495 V, v_off_fin = -0.000001279 V 07:23:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291152 Vs 07:23:49 Temperature Measurement, Probe Number = 0, T = 20.358000 C 07:23:49 Temperature Measurement, Probe Number = 1, T = 20.017000 C 07:23:50 Temperature Measurement, Probe Number = 2, T = 19.985000 C 07:23:51 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:23:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:23:51 Integrated Voltage Measurement... 07:24:10 Voltage Offset Correction: v_off_ini = 0.000002346 V, v_off_fin = 0.000007641 V 07:24:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424691 Vs 07:24:10 Integrated Voltage Measurement... 07:24:29 Voltage Offset Correction: v_off_ini = 0.000005732 V, v_off_fin = -0.000001010 V 07:24:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283560 Vs 07:24:32 Temperature Measurement, Probe Number = 0, T = 20.266000 C 07:24:33 Temperature Measurement, Probe Number = 1, T = 20.014000 C 07:24:34 Temperature Measurement, Probe Number = 2, T = 19.983000 C 07:24:34 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:24:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:24:34 Integrated Voltage Measurement... 07:24:53 Voltage Offset Correction: v_off_ini = 0.000001004 V, v_off_fin = 0.000006992 V 07:24:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428445 Vs 07:24:54 Integrated Voltage Measurement... 07:25:13 Voltage Offset Correction: v_off_ini = 0.000006327 V, v_off_fin = -0.000002320 V 07:25:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281292 Vs 07:25:15 Temperature Measurement, Probe Number = 0, T = 20.240000 C 07:25:16 Temperature Measurement, Probe Number = 1, T = 20.019000 C 07:25:17 Temperature Measurement, Probe Number = 2, T = 19.986000 C 07:25:17 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:25:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 07:25:17 Integrated Voltage Measurement... 07:25:37 Voltage Offset Correction: v_off_ini = 0.000002069 V, v_off_fin = 0.000006702 V 07:25:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432209 Vs 07:25:37 Integrated Voltage Measurement... 07:25:56 Voltage Offset Correction: v_off_ini = 0.000006342 V, v_off_fin = -0.000001383 V 07:25:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286308 Vs 07:25:59 Temperature Measurement, Probe Number = 0, T = 20.272000 C 07:26:00 Temperature Measurement, Probe Number = 1, T = 20.022000 C 07:26:00 Temperature Measurement, Probe Number = 2, T = 19.991000 C 07:26:01 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:26:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 07:26:01 Integrated Voltage Measurement... 07:26:20 Voltage Offset Correction: v_off_ini = 0.000002322 V, v_off_fin = 0.000006809 V 07:26:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175423268 Vs 07:26:21 Integrated Voltage Measurement... 07:26:40 Voltage Offset Correction: v_off_ini = 0.000006216 V, v_off_fin = -0.000001239 V 07:26:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175280018 Vs 07:26:42 Temperature Measurement, Probe Number = 0, T = 20.290000 C 07:26:43 Temperature Measurement, Probe Number = 1, T = 20.020000 C 07:26:44 Temperature Measurement, Probe Number = 2, T = 19.990000 C 07:26:44 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:26:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 07:26:45 Integrated Voltage Measurement... 07:27:04 Voltage Offset Correction: v_off_ini = 0.000002134 V, v_off_fin = 0.000006792 V 07:27:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428587 Vs 07:27:04 Integrated Voltage Measurement... 07:27:23 Voltage Offset Correction: v_off_ini = 0.000006286 V, v_off_fin = -0.000000413 V 07:27:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282734 Vs 07:27:26 Temperature Measurement, Probe Number = 0, T = 20.304000 C 07:27:26 Temperature Measurement, Probe Number = 1, T = 20.022000 C 07:27:27 Temperature Measurement, Probe Number = 2, T = 19.992000 C 07:27:27 Temperature Measurement, Probe Number = 3, T = 19.968000 C 07:27:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 07:27:28 Integrated Voltage Measurement... 07:27:47 Voltage Offset Correction: v_off_ini = 0.000002247 V, v_off_fin = 0.000007254 V 07:27:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430296 Vs 07:27:47 Integrated Voltage Measurement... 07:28:06 Voltage Offset Correction: v_off_ini = 0.000006012 V, v_off_fin = -0.000001463 V 07:28:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282803 Vs 07:28:09 Temperature Measurement, Probe Number = 0, T = 20.324000 C 07:28:09 Temperature Measurement, Probe Number = 1, T = 20.021000 C 07:28:10 Temperature Measurement, Probe Number = 2, T = 19.991000 C 07:28:11 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:28:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 07:28:11 Integrated Voltage Measurement... 07:28:30 Voltage Offset Correction: v_off_ini = 0.000003012 V, v_off_fin = 0.000006872 V 07:28:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433163 Vs 07:28:30 Integrated Voltage Measurement... 07:28:49 Voltage Offset Correction: v_off_ini = 0.000005668 V, v_off_fin = -0.000001663 V 07:28:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293026 Vs 07:28:52 Temperature Measurement, Probe Number = 0, T = 20.284000 C 07:28:53 Temperature Measurement, Probe Number = 1, T = 20.018000 C 07:28:54 Temperature Measurement, Probe Number = 2, T = 19.987000 C 07:28:54 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:28:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 07:28:54 Integrated Voltage Measurement... 07:29:14 Voltage Offset Correction: v_off_ini = 0.000002664 V, v_off_fin = 0.000006604 V 07:29:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422685 Vs 07:29:14 Integrated Voltage Measurement... 07:29:34 Voltage Offset Correction: v_off_ini = 0.000005856 V, v_off_fin = -0.000001260 V 07:29:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295182 Vs 07:59:36 Temperature Measurement, Probe Number = 0, T = 20.265000 C 07:59:37 Temperature Measurement, Probe Number = 1, T = 20.016000 C 07:59:38 Temperature Measurement, Probe Number = 2, T = 19.987000 C 07:59:38 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:59:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 07:59:39 Integrated Voltage Measurement... 07:59:57 Voltage Offset Correction: v_off_ini = 0.000004838 V, v_off_fin = 0.000007088 V 07:59:58 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175520607 Vs 07:59:58 Integrated Voltage Measurement... 08:00:17 Voltage Offset Correction: v_off_ini = 0.000006901 V, v_off_fin = -0.000001270 V 08:00:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282585 Vs 08:00:20 Temperature Measurement, Probe Number = 0, T = 20.211000 C 08:00:20 Temperature Measurement, Probe Number = 1, T = 20.017000 C 08:00:21 Temperature Measurement, Probe Number = 2, T = 19.988000 C 08:00:22 Temperature Measurement, Probe Number = 3, T = 19.963000 C 08:00:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 08:00:22 Integrated Voltage Measurement... 08:00:41 Voltage Offset Correction: v_off_ini = 0.000003047 V, v_off_fin = 0.000007185 V 08:00:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431058 Vs 08:00:41 Integrated Voltage Measurement... 08:01:00 Voltage Offset Correction: v_off_ini = 0.000006852 V, v_off_fin = -0.000001097 V 08:01:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284903 Vs 08:01:03 Temperature Measurement, Probe Number = 0, T = 20.230000 C 08:01:04 Temperature Measurement, Probe Number = 1, T = 20.021000 C 08:01:05 Temperature Measurement, Probe Number = 2, T = 19.989000 C 08:01:05 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:01:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 08:01:05 Integrated Voltage Measurement... 08:01:25 Voltage Offset Correction: v_off_ini = 0.000002867 V, v_off_fin = 0.000007314 V 08:01:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429270 Vs 08:01:25 Integrated Voltage Measurement... 08:01:45 Voltage Offset Correction: v_off_ini = 0.000006333 V, v_off_fin = -0.000000661 V 08:01:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286508 Vs 08:01:47 Temperature Measurement, Probe Number = 0, T = 20.265000 C 08:01:48 Temperature Measurement, Probe Number = 1, T = 20.019000 C 08:01:49 Temperature Measurement, Probe Number = 2, T = 19.988000 C 08:01:49 Temperature Measurement, Probe Number = 3, T = 19.965000 C 08:01:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 08:01:49 Integrated Voltage Measurement... 08:02:09 Voltage Offset Correction: v_off_ini = 0.000002012 V, v_off_fin = 0.000007114 V 08:02:09 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429615 Vs 08:02:09 Integrated Voltage Measurement... 08:02:28 Voltage Offset Correction: v_off_ini = 0.000006349 V, v_off_fin = -0.000001998 V 08:02:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281181 Vs 08:02:31 Temperature Measurement, Probe Number = 0, T = 20.244000 C 08:02:32 Temperature Measurement, Probe Number = 1, T = 20.018000 C 08:02:32 Temperature Measurement, Probe Number = 2, T = 19.989000 C 08:02:33 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:02:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 08:02:33 Integrated Voltage Measurement... 08:02:52 Voltage Offset Correction: v_off_ini = 0.000001583 V, v_off_fin = 0.000006417 V 08:02:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427989 Vs 08:02:52 Integrated Voltage Measurement... 08:03:12 Voltage Offset Correction: v_off_ini = 0.000005826 V, v_off_fin = -0.000001417 V 08:03:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290089 Vs 08:03:15 Temperature Measurement, Probe Number = 0, T = 20.228000 C 08:03:15 Temperature Measurement, Probe Number = 1, T = 20.018000 C 08:03:16 Temperature Measurement, Probe Number = 2, T = 19.989000 C 08:03:16 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:03:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 08:03:17 Integrated Voltage Measurement... 08:03:36 Voltage Offset Correction: v_off_ini = 0.000002686 V, v_off_fin = 0.000006871 V 08:03:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426421 Vs 08:03:36 Integrated Voltage Measurement... 08:03:56 Voltage Offset Correction: v_off_ini = 0.000006201 V, v_off_fin = -0.000000878 V 08:03:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285182 Vs 08:03:59 Temperature Measurement, Probe Number = 0, T = 20.232000 C 08:04:00 Temperature Measurement, Probe Number = 1, T = 20.020000 C 08:04:00 Temperature Measurement, Probe Number = 2, T = 19.987000 C 08:04:01 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:04:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 08:04:01 Integrated Voltage Measurement... 08:04:20 Voltage Offset Correction: v_off_ini = 0.000001650 V, v_off_fin = 0.000007847 V 08:04:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420172 Vs 08:04:20 Integrated Voltage Measurement... 08:04:39 Voltage Offset Correction: v_off_ini = 0.000005564 V, v_off_fin = -0.000001837 V 08:04:39 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175286319 Vs 08:04:42 Temperature Measurement, Probe Number = 0, T = 20.238000 C 08:04:43 Temperature Measurement, Probe Number = 1, T = 20.018000 C 08:04:43 Temperature Measurement, Probe Number = 2, T = 19.989000 C 08:04:44 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:04:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 08:04:44 Integrated Voltage Measurement... 08:05:03 Voltage Offset Correction: v_off_ini = 0.000001977 V, v_off_fin = 0.000006761 V 08:05:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428801 Vs 08:05:03 Integrated Voltage Measurement... 08:05:23 Voltage Offset Correction: v_off_ini = 0.000005936 V, v_off_fin = -0.000001723 V 08:05:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294432 Vs 08:05:25 Temperature Measurement, Probe Number = 0, T = 20.256000 C 08:05:26 Temperature Measurement, Probe Number = 1, T = 20.022000 C 08:05:27 Temperature Measurement, Probe Number = 2, T = 19.992000 C 08:05:27 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:05:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 08:05:28 Integrated Voltage Measurement... 08:05:47 Voltage Offset Correction: v_off_ini = 0.000002020 V, v_off_fin = 0.000006769 V 08:05:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434459 Vs 08:05:47 Integrated Voltage Measurement... 08:06:06 Voltage Offset Correction: v_off_ini = 0.000006313 V, v_off_fin = -0.000001891 V 08:06:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286697 Vs 08:06:09 Temperature Measurement, Probe Number = 0, T = 20.322000 C 08:06:10 Temperature Measurement, Probe Number = 1, T = 20.024000 C 08:06:11 Temperature Measurement, Probe Number = 2, T = 19.995000 C 08:06:11 Temperature Measurement, Probe Number = 3, T = 19.969000 C 08:06:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:06:11 Integrated Voltage Measurement... 08:06:30 Voltage Offset Correction: v_off_ini = 0.000002433 V, v_off_fin = 0.000006215 V 08:06:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429639 Vs 08:06:31 Integrated Voltage Measurement... 08:06:50 Voltage Offset Correction: v_off_ini = 0.000006080 V, v_off_fin = -0.000000788 V 08:06:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289569 Vs 08:36:53 Temperature Measurement, Probe Number = 0, T = 20.339000 C 08:36:54 Temperature Measurement, Probe Number = 1, T = 20.025000 C 08:36:54 Temperature Measurement, Probe Number = 2, T = 19.998000 C 08:36:55 Temperature Measurement, Probe Number = 3, T = 19.971000 C 08:36:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:36:55 Integrated Voltage Measurement... 08:37:15 Voltage Offset Correction: v_off_ini = 0.000003869 V, v_off_fin = 0.000006205 V 08:37:15 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175515185 Vs 08:37:15 Integrated Voltage Measurement... 08:37:34 Voltage Offset Correction: v_off_ini = 0.000005818 V, v_off_fin = -0.000001406 V 08:37:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292666 Vs 08:37:37 Temperature Measurement, Probe Number = 0, T = 20.366000 C 08:37:38 Temperature Measurement, Probe Number = 1, T = 20.024000 C 08:37:38 Temperature Measurement, Probe Number = 2, T = 19.998000 C 08:37:39 Temperature Measurement, Probe Number = 3, T = 19.970000 C 08:37:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:37:39 Integrated Voltage Measurement... 08:37:58 Voltage Offset Correction: v_off_ini = 0.000002410 V, v_off_fin = 0.000006929 V 08:37:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428963 Vs 08:37:58 Integrated Voltage Measurement... 08:38:17 Voltage Offset Correction: v_off_ini = 0.000006070 V, v_off_fin = -0.000001978 V 08:38:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285855 Vs 08:38:20 Temperature Measurement, Probe Number = 0, T = 20.339000 C 08:38:21 Temperature Measurement, Probe Number = 1, T = 20.025000 C 08:38:22 Temperature Measurement, Probe Number = 2, T = 19.998000 C 08:38:22 Temperature Measurement, Probe Number = 3, T = 19.969000 C 08:38:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:38:22 Integrated Voltage Measurement... 08:38:41 Voltage Offset Correction: v_off_ini = 0.000002319 V, v_off_fin = 0.000006714 V 08:38:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432425 Vs 08:38:42 Integrated Voltage Measurement... 08:39:01 Voltage Offset Correction: v_off_ini = 0.000006083 V, v_off_fin = -0.000002161 V 08:39:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293450 Vs 08:39:04 Temperature Measurement, Probe Number = 0, T = 20.344000 C 08:39:04 Temperature Measurement, Probe Number = 1, T = 20.027000 C 08:39:05 Temperature Measurement, Probe Number = 2, T = 19.999000 C 08:39:06 Temperature Measurement, Probe Number = 3, T = 19.972000 C 08:39:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:39:06 Integrated Voltage Measurement... 08:39:25 Voltage Offset Correction: v_off_ini = 0.000002150 V, v_off_fin = 0.000005901 V 08:39:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418719 Vs 08:39:25 Integrated Voltage Measurement... 08:39:44 Voltage Offset Correction: v_off_ini = 0.000005274 V, v_off_fin = -0.000002529 V 08:39:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298866 Vs 08:39:47 Temperature Measurement, Probe Number = 0, T = 20.345000 C 08:39:48 Temperature Measurement, Probe Number = 1, T = 20.027000 C 08:39:48 Temperature Measurement, Probe Number = 2, T = 19.998000 C 08:39:49 Temperature Measurement, Probe Number = 3, T = 19.969000 C 08:39:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:39:49 Integrated Voltage Measurement... 08:40:08 Voltage Offset Correction: v_off_ini = 0.000001931 V, v_off_fin = 0.000006881 V 08:40:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433896 Vs 08:40:09 Integrated Voltage Measurement... 08:40:28 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001386 V 08:40:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288705 Vs 08:40:31 Temperature Measurement, Probe Number = 0, T = 20.321000 C 08:40:31 Temperature Measurement, Probe Number = 1, T = 20.028000 C 08:40:32 Temperature Measurement, Probe Number = 2, T = 19.999000 C 08:40:32 Temperature Measurement, Probe Number = 3, T = 19.972000 C 08:40:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:40:33 Integrated Voltage Measurement... 08:40:52 Voltage Offset Correction: v_off_ini = 0.000002639 V, v_off_fin = 0.000006176 V 08:40:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440662 Vs 08:40:53 Integrated Voltage Measurement... 08:41:12 Voltage Offset Correction: v_off_ini = 0.000005685 V, v_off_fin = -0.000002043 V 08:41:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285137 Vs 08:41:14 Temperature Measurement, Probe Number = 0, T = 20.291000 C 08:41:15 Temperature Measurement, Probe Number = 1, T = 20.028000 C 08:41:16 Temperature Measurement, Probe Number = 2, T = 19.999000 C 08:41:16 Temperature Measurement, Probe Number = 3, T = 19.973000 C 08:41:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:41:17 Integrated Voltage Measurement... 08:41:35 Voltage Offset Correction: v_off_ini = 0.000002017 V, v_off_fin = 0.000006678 V 08:41:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436174 Vs 08:41:36 Integrated Voltage Measurement... 08:41:55 Voltage Offset Correction: v_off_ini = 0.000005878 V, v_off_fin = -0.000002618 V 08:41:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299832 Vs 08:41:58 Temperature Measurement, Probe Number = 0, T = 20.332000 C 08:41:59 Temperature Measurement, Probe Number = 1, T = 20.028000 C 08:41:59 Temperature Measurement, Probe Number = 2, T = 20.000000 C 08:42:00 Temperature Measurement, Probe Number = 3, T = 19.972000 C 08:42:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:42:00 Integrated Voltage Measurement... 08:42:20 Voltage Offset Correction: v_off_ini = 0.000002127 V, v_off_fin = 0.000005962 V 08:42:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420776 Vs 08:42:20 Integrated Voltage Measurement... 08:42:39 Voltage Offset Correction: v_off_ini = 0.000005311 V, v_off_fin = -0.000001517 V 08:42:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295001 Vs 08:42:42 Temperature Measurement, Probe Number = 0, T = 20.402000 C 08:42:43 Temperature Measurement, Probe Number = 1, T = 20.028000 C 08:42:43 Temperature Measurement, Probe Number = 2, T = 20.002000 C 08:42:44 Temperature Measurement, Probe Number = 3, T = 19.971000 C 08:42:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:42:44 Integrated Voltage Measurement... 08:43:03 Voltage Offset Correction: v_off_ini = 0.000002393 V, v_off_fin = 0.000006520 V 08:43:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431546 Vs 08:43:04 Integrated Voltage Measurement... 08:43:23 Voltage Offset Correction: v_off_ini = 0.000006007 V, v_off_fin = -0.000001487 V 08:43:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289240 Vs 08:43:26 Temperature Measurement, Probe Number = 0, T = 20.401000 C 08:43:27 Temperature Measurement, Probe Number = 1, T = 20.027000 C 08:43:27 Temperature Measurement, Probe Number = 2, T = 20.001000 C 08:43:28 Temperature Measurement, Probe Number = 3, T = 19.971000 C 08:43:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:43:28 Integrated Voltage Measurement... 08:43:48 Voltage Offset Correction: v_off_ini = 0.000002437 V, v_off_fin = 0.000007099 V 08:43:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440458 Vs 08:43:48 Integrated Voltage Measurement... 08:44:08 Voltage Offset Correction: v_off_ini = 0.000006088 V, v_off_fin = -0.000000645 V 08:44:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297601 Vs 09:14:11 Temperature Measurement, Probe Number = 0, T = 20.315000 C 09:14:11 Temperature Measurement, Probe Number = 1, T = 20.028000 C 09:14:12 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:14:13 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:14:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:14:13 Integrated Voltage Measurement... 09:14:32 Voltage Offset Correction: v_off_ini = 0.000004637 V, v_off_fin = 0.000007033 V 09:14:32 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175531529 Vs 09:14:33 Integrated Voltage Measurement... 09:14:52 Voltage Offset Correction: v_off_ini = 0.000005917 V, v_off_fin = -0.000001603 V 09:14:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175286062 Vs 09:14:54 Temperature Measurement, Probe Number = 0, T = 20.359000 C 09:14:55 Temperature Measurement, Probe Number = 1, T = 20.028000 C 09:14:56 Temperature Measurement, Probe Number = 2, T = 20.002000 C 09:14:56 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:14:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:14:57 Integrated Voltage Measurement... 09:15:16 Voltage Offset Correction: v_off_ini = 0.000001460 V, v_off_fin = 0.000006954 V 09:15:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432488 Vs 09:15:16 Integrated Voltage Measurement... 09:15:36 Voltage Offset Correction: v_off_ini = 0.000006046 V, v_off_fin = -0.000001170 V 09:15:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175285602 Vs 09:15:38 Temperature Measurement, Probe Number = 0, T = 20.337000 C 09:15:39 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:15:40 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:15:40 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:15:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 09:15:41 Integrated Voltage Measurement... 09:16:00 Voltage Offset Correction: v_off_ini = 0.000002727 V, v_off_fin = 0.000007130 V 09:16:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427699 Vs 09:16:00 Integrated Voltage Measurement... 09:16:19 Voltage Offset Correction: v_off_ini = 0.000005670 V, v_off_fin = -0.000001611 V 09:16:20 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175293184 Vs 09:16:22 Temperature Measurement, Probe Number = 0, T = 20.342000 C 09:16:23 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:16:24 Temperature Measurement, Probe Number = 2, T = 20.005000 C 09:16:24 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:16:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:16:25 Integrated Voltage Measurement... 09:16:44 Voltage Offset Correction: v_off_ini = 0.000002481 V, v_off_fin = 0.000006954 V 09:16:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426617 Vs 09:16:44 Integrated Voltage Measurement... 09:17:03 Voltage Offset Correction: v_off_ini = 0.000006634 V, v_off_fin = -0.000001694 V 09:17:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285207 Vs 09:17:06 Temperature Measurement, Probe Number = 0, T = 20.315000 C 09:17:06 Temperature Measurement, Probe Number = 1, T = 20.028000 C 09:17:07 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:17:08 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:17:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 09:17:08 Integrated Voltage Measurement... 09:17:27 Voltage Offset Correction: v_off_ini = 0.000002150 V, v_off_fin = 0.000006913 V 09:17:27 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175432336 Vs 09:17:27 Integrated Voltage Measurement... 09:17:47 Voltage Offset Correction: v_off_ini = 0.000006083 V, v_off_fin = -0.000001222 V 09:17:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280237 Vs 09:17:49 Temperature Measurement, Probe Number = 0, T = 20.374000 C 09:17:50 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:17:51 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:17:51 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:17:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:17:52 Integrated Voltage Measurement... 09:18:11 Voltage Offset Correction: v_off_ini = 0.000001675 V, v_off_fin = 0.000006247 V 09:18:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424714 Vs 09:18:11 Integrated Voltage Measurement... 09:18:30 Voltage Offset Correction: v_off_ini = 0.000005370 V, v_off_fin = -0.000002763 V 09:18:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285095 Vs 09:18:33 Temperature Measurement, Probe Number = 0, T = 20.363000 C 09:18:34 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:18:34 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:18:35 Temperature Measurement, Probe Number = 3, T = 19.973000 C 09:18:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:18:35 Integrated Voltage Measurement... 09:18:55 Voltage Offset Correction: v_off_ini = 0.000002510 V, v_off_fin = 0.000006652 V 09:18:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429065 Vs 09:18:55 Integrated Voltage Measurement... 09:19:14 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000001098 V 09:19:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283191 Vs 09:19:17 Temperature Measurement, Probe Number = 0, T = 20.293000 C 09:19:18 Temperature Measurement, Probe Number = 1, T = 20.028000 C 09:19:18 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:19:19 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:19:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:19:19 Integrated Voltage Measurement... 09:19:38 Voltage Offset Correction: v_off_ini = 0.000002019 V, v_off_fin = 0.000006257 V 09:19:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426608 Vs 09:19:38 Integrated Voltage Measurement... 09:19:58 Voltage Offset Correction: v_off_ini = 0.000005452 V, v_off_fin = -0.000002165 V 09:19:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290254 Vs 09:20:01 Temperature Measurement, Probe Number = 0, T = 20.327000 C 09:20:01 Temperature Measurement, Probe Number = 1, T = 20.031000 C 09:20:02 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:20:03 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:20:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:20:03 Integrated Voltage Measurement... 09:20:22 Voltage Offset Correction: v_off_ini = 0.000001115 V, v_off_fin = 0.000006033 V 09:20:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413501 Vs 09:20:22 Integrated Voltage Measurement... 09:20:41 Voltage Offset Correction: v_off_ini = 0.000005715 V, v_off_fin = -0.000000947 V 09:20:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289165 Vs 09:20:44 Temperature Measurement, Probe Number = 0, T = 20.338000 C 09:20:45 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:20:45 Temperature Measurement, Probe Number = 2, T = 19.998000 C 09:20:46 Temperature Measurement, Probe Number = 3, T = 19.970000 C 09:20:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:20:46 Integrated Voltage Measurement... 09:21:05 Voltage Offset Correction: v_off_ini = 0.000001317 V, v_off_fin = 0.000006612 V 09:21:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422567 Vs 09:21:06 Integrated Voltage Measurement... 09:21:25 Voltage Offset Correction: v_off_ini = 0.000005775 V, v_off_fin = -0.000001063 V 09:21:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286261 Vs 09:51:28 Temperature Measurement, Probe Number = 0, T = 20.271000 C 09:51:29 Temperature Measurement, Probe Number = 1, T = 20.031000 C 09:51:29 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:51:30 Temperature Measurement, Probe Number = 3, T = 19.973000 C 09:51:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:51:30 Integrated Voltage Measurement... 09:51:49 Voltage Offset Correction: v_off_ini = 0.000004583 V, v_off_fin = 0.000006741 V 09:51:49 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175519399 Vs 09:51:49 Integrated Voltage Measurement... 09:52:09 Voltage Offset Correction: v_off_ini = 0.000005594 V, v_off_fin = -0.000001345 V 09:52:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175278977 Vs 09:52:11 Temperature Measurement, Probe Number = 0, T = 20.262000 C 09:52:12 Temperature Measurement, Probe Number = 1, T = 20.032000 C 09:52:13 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:52:13 Temperature Measurement, Probe Number = 3, T = 19.973000 C 09:52:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:52:14 Integrated Voltage Measurement... 09:52:33 Voltage Offset Correction: v_off_ini = 0.000002243 V, v_off_fin = 0.000007005 V 09:52:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422681 Vs 09:52:33 Integrated Voltage Measurement... 09:52:54 Voltage Offset Correction: v_off_ini = 0.000006172 V, v_off_fin = -0.000000617 V 09:52:54 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175279731 Vs 09:52:56 Temperature Measurement, Probe Number = 0, T = 20.245000 C 09:52:57 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:52:58 Temperature Measurement, Probe Number = 2, T = 20.002000 C 09:52:58 Temperature Measurement, Probe Number = 3, T = 19.972000 C 09:52:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:52:59 Integrated Voltage Measurement... 09:53:18 Voltage Offset Correction: v_off_ini = 0.000001856 V, v_off_fin = 0.000006448 V 09:53:18 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175402570 Vs 09:53:18 Integrated Voltage Measurement... 09:53:39 Voltage Offset Correction: v_off_ini = 0.000006140 V, v_off_fin = -0.000000155 V 09:53:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175283154 Vs 09:53:42 Temperature Measurement, Probe Number = 0, T = 20.255000 C 09:53:42 Temperature Measurement, Probe Number = 1, T = 20.027000 C 09:53:43 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:53:44 Temperature Measurement, Probe Number = 3, T = 19.971000 C 09:53:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:53:44 Integrated Voltage Measurement... 09:54:03 Voltage Offset Correction: v_off_ini = 0.000001960 V, v_off_fin = 0.000006294 V 09:54:03 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175408539 Vs 09:54:04 Integrated Voltage Measurement... 09:54:23 Voltage Offset Correction: v_off_ini = 0.000006262 V, v_off_fin = -0.000001237 V 09:54:23 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175280642 Vs 09:54:26 Temperature Measurement, Probe Number = 0, T = 20.252000 C 09:54:27 Temperature Measurement, Probe Number = 1, T = 20.032000 C 09:54:27 Temperature Measurement, Probe Number = 2, T = 20.010000 C 09:54:28 Temperature Measurement, Probe Number = 3, T = 19.973000 C 09:54:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 09:54:28 Integrated Voltage Measurement... 09:54:47 Voltage Offset Correction: v_off_ini = 0.000002835 V, v_off_fin = 0.000006778 V 09:54:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426327 Vs 09:54:48 Integrated Voltage Measurement... 09:55:06 Voltage Offset Correction: v_off_ini = 0.000006150 V, v_off_fin = -0.000001039 V 09:55:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175278014 Vs 09:55:09 Temperature Measurement, Probe Number = 0, T = 20.291000 C 09:55:10 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:55:11 Temperature Measurement, Probe Number = 2, T = 20.006000 C 09:55:11 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:55:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 09:55:11 Integrated Voltage Measurement... 09:55:30 Voltage Offset Correction: v_off_ini = 0.000001994 V, v_off_fin = 0.000005976 V 09:55:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421840 Vs 09:55:31 Integrated Voltage Measurement... 09:55:50 Voltage Offset Correction: v_off_ini = 0.000005027 V, v_off_fin = -0.000001149 V 09:55:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292455 Vs 09:55:53 Temperature Measurement, Probe Number = 0, T = 20.324000 C 09:55:54 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:55:54 Temperature Measurement, Probe Number = 2, T = 20.005000 C 09:55:55 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:55:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 09:55:55 Integrated Voltage Measurement... 09:56:14 Voltage Offset Correction: v_off_ini = 0.000002251 V, v_off_fin = 0.000006909 V 09:56:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430319 Vs 09:56:14 Integrated Voltage Measurement... 09:56:33 Voltage Offset Correction: v_off_ini = 0.000006412 V, v_off_fin = -0.000001907 V 09:56:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287024 Vs 09:56:36 Temperature Measurement, Probe Number = 0, T = 20.308000 C 09:56:37 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:56:37 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:56:38 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:56:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:56:38 Integrated Voltage Measurement... 09:56:58 Voltage Offset Correction: v_off_ini = 0.000000811 V, v_off_fin = 0.000006375 V 09:56:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433421 Vs 09:56:58 Integrated Voltage Measurement... 09:57:17 Voltage Offset Correction: v_off_ini = 0.000007929 V, v_off_fin = -0.000001890 V 09:57:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286491 Vs 09:57:20 Temperature Measurement, Probe Number = 0, T = 20.328000 C 09:57:21 Temperature Measurement, Probe Number = 1, T = 20.028000 C 09:57:22 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:57:22 Temperature Measurement, Probe Number = 3, T = 19.975000 C 09:57:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 09:57:22 Integrated Voltage Measurement... 09:57:42 Voltage Offset Correction: v_off_ini = 0.000002241 V, v_off_fin = 0.000006177 V 09:57:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426959 Vs 09:57:42 Integrated Voltage Measurement... 09:58:01 Voltage Offset Correction: v_off_ini = 0.000005691 V, v_off_fin = -0.000001563 V 09:58:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302604 Vs 09:58:04 Temperature Measurement, Probe Number = 0, T = 20.291000 C 09:58:05 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:58:05 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:58:06 Temperature Measurement, Probe Number = 3, T = 19.974000 C 09:58:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 09:58:06 Integrated Voltage Measurement... 09:58:25 Voltage Offset Correction: v_off_ini = 0.000001631 V, v_off_fin = 0.000005784 V 09:58:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418637 Vs 09:58:26 Integrated Voltage Measurement... 09:58:45 Voltage Offset Correction: v_off_ini = 0.000005395 V, v_off_fin = -0.000002182 V 09:58:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288903 Vs 10:28:48 Temperature Measurement, Probe Number = 0, T = 20.296000 C 10:28:48 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:28:49 Temperature Measurement, Probe Number = 2, T = 20.002000 C 10:28:50 Temperature Measurement, Probe Number = 3, T = 19.974000 C 10:28:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:28:50 Integrated Voltage Measurement... 10:29:09 Voltage Offset Correction: v_off_ini = 0.000003869 V, v_off_fin = 0.000006603 V 10:29:09 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175524651 Vs 10:29:09 Integrated Voltage Measurement... 10:29:28 Voltage Offset Correction: v_off_ini = 0.000005737 V, v_off_fin = -0.000002121 V 10:29:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282452 Vs 10:29:31 Temperature Measurement, Probe Number = 0, T = 20.262000 C 10:29:32 Temperature Measurement, Probe Number = 1, T = 20.032000 C 10:29:33 Temperature Measurement, Probe Number = 2, T = 20.004000 C 10:29:33 Temperature Measurement, Probe Number = 3, T = 19.974000 C 10:29:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:29:33 Integrated Voltage Measurement... 10:29:52 Voltage Offset Correction: v_off_ini = 0.000000748 V, v_off_fin = 0.000007753 V 10:29:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418529 Vs 10:29:53 Integrated Voltage Measurement... 10:30:12 Voltage Offset Correction: v_off_ini = 0.000005553 V, v_off_fin = -0.000002274 V 10:30:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287859 Vs 10:30:15 Temperature Measurement, Probe Number = 0, T = 20.291000 C 10:30:15 Temperature Measurement, Probe Number = 1, T = 20.034000 C 10:30:16 Temperature Measurement, Probe Number = 2, T = 20.007000 C 10:30:17 Temperature Measurement, Probe Number = 3, T = 19.979000 C 10:30:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 10:30:17 Integrated Voltage Measurement... 10:30:36 Voltage Offset Correction: v_off_ini = 0.000001966 V, v_off_fin = 0.000006575 V 10:30:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430385 Vs 10:30:37 Integrated Voltage Measurement... 10:30:56 Voltage Offset Correction: v_off_ini = 0.000005646 V, v_off_fin = -0.000002009 V 10:30:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286376 Vs 10:30:59 Temperature Measurement, Probe Number = 0, T = 20.293000 C 10:30:59 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:31:00 Temperature Measurement, Probe Number = 2, T = 20.005000 C 10:31:01 Temperature Measurement, Probe Number = 3, T = 19.978000 C 10:31:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:31:01 Integrated Voltage Measurement... 10:31:20 Voltage Offset Correction: v_off_ini = 0.000001155 V, v_off_fin = 0.000006532 V 10:31:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423415 Vs 10:31:21 Integrated Voltage Measurement... 10:31:40 Voltage Offset Correction: v_off_ini = 0.000005770 V, v_off_fin = -0.000001981 V 10:31:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285219 Vs 10:31:43 Temperature Measurement, Probe Number = 0, T = 20.244000 C 10:31:43 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:31:44 Temperature Measurement, Probe Number = 2, T = 20.005000 C 10:31:44 Temperature Measurement, Probe Number = 3, T = 19.974000 C 10:31:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:31:45 Integrated Voltage Measurement... 10:32:04 Voltage Offset Correction: v_off_ini = 0.000001505 V, v_off_fin = 0.000006502 V 10:32:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428621 Vs 10:32:04 Integrated Voltage Measurement... 10:32:24 Voltage Offset Correction: v_off_ini = 0.000005660 V, v_off_fin = -0.000002387 V 10:32:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175294231 Vs 10:32:27 Temperature Measurement, Probe Number = 0, T = 20.225000 C 10:32:27 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:32:28 Temperature Measurement, Probe Number = 2, T = 20.005000 C 10:32:29 Temperature Measurement, Probe Number = 3, T = 19.973000 C 10:32:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:32:29 Integrated Voltage Measurement... 10:32:48 Voltage Offset Correction: v_off_ini = 0.000002308 V, v_off_fin = 0.000005732 V 10:32:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413708 Vs 10:32:48 Integrated Voltage Measurement... 10:33:07 Voltage Offset Correction: v_off_ini = 0.000004664 V, v_off_fin = -0.000002013 V 10:33:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299986 Vs 10:33:10 Temperature Measurement, Probe Number = 0, T = 20.198000 C 10:33:11 Temperature Measurement, Probe Number = 1, T = 20.034000 C 10:33:12 Temperature Measurement, Probe Number = 2, T = 20.001000 C 10:33:12 Temperature Measurement, Probe Number = 3, T = 19.971000 C 10:33:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:33:12 Integrated Voltage Measurement... 10:33:32 Voltage Offset Correction: v_off_ini = 0.000001729 V, v_off_fin = 0.000005992 V 10:33:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422423 Vs 10:33:32 Integrated Voltage Measurement... 10:33:52 Voltage Offset Correction: v_off_ini = 0.000005321 V, v_off_fin = -0.000001603 V 10:33:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300097 Vs 10:33:55 Temperature Measurement, Probe Number = 0, T = 20.230000 C 10:33:55 Temperature Measurement, Probe Number = 1, T = 20.031000 C 10:33:56 Temperature Measurement, Probe Number = 2, T = 20.004000 C 10:33:57 Temperature Measurement, Probe Number = 3, T = 19.973000 C 10:33:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 10:33:57 Integrated Voltage Measurement... 10:34:16 Voltage Offset Correction: v_off_ini = 0.000002211 V, v_off_fin = 0.000006555 V 10:34:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419470 Vs 10:34:16 Integrated Voltage Measurement... 10:34:36 Voltage Offset Correction: v_off_ini = 0.000005911 V, v_off_fin = -0.000000981 V 10:34:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294157 Vs 10:34:38 Temperature Measurement, Probe Number = 0, T = 20.230000 C 10:34:39 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:34:40 Temperature Measurement, Probe Number = 2, T = 20.006000 C 10:34:40 Temperature Measurement, Probe Number = 3, T = 19.975000 C 10:34:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 10:34:41 Integrated Voltage Measurement... 10:35:00 Voltage Offset Correction: v_off_ini = 0.000001675 V, v_off_fin = 0.000005933 V 10:35:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424075 Vs 10:35:00 Integrated Voltage Measurement... 10:35:20 Voltage Offset Correction: v_off_ini = 0.000005487 V, v_off_fin = -0.000000828 V 10:35:20 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293320 Vs 10:35:23 Temperature Measurement, Probe Number = 0, T = 20.247000 C 10:35:24 Temperature Measurement, Probe Number = 1, T = 20.032000 C 10:35:24 Temperature Measurement, Probe Number = 2, T = 20.006000 C 10:35:25 Temperature Measurement, Probe Number = 3, T = 19.974000 C 10:35:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 10:35:25 Integrated Voltage Measurement... 10:35:44 Voltage Offset Correction: v_off_ini = 0.000002775 V, v_off_fin = 0.000006996 V 10:35:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175422629 Vs 10:35:44 Integrated Voltage Measurement... 10:36:04 Voltage Offset Correction: v_off_ini = 0.000005850 V, v_off_fin = -0.000000747 V 10:36:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299807 Vs 11:06:07 Temperature Measurement, Probe Number = 0, T = 20.223000 C 11:06:08 Temperature Measurement, Probe Number = 1, T = 20.033000 C 11:06:08 Temperature Measurement, Probe Number = 2, T = 20.005000 C 11:06:09 Temperature Measurement, Probe Number = 3, T = 19.973000 C 11:06:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 11:06:09 Integrated Voltage Measurement... 11:06:28 Voltage Offset Correction: v_off_ini = 0.000004280 V, v_off_fin = 0.000006134 V 11:06:29 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175517489 Vs 11:06:29 Integrated Voltage Measurement... 11:06:48 Voltage Offset Correction: v_off_ini = 0.000005432 V, v_off_fin = -0.000002032 V 11:06:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285419 Vs 11:06:51 Temperature Measurement, Probe Number = 0, T = 20.258000 C 11:06:51 Temperature Measurement, Probe Number = 1, T = 20.036000 C 11:06:52 Temperature Measurement, Probe Number = 2, T = 20.007000 C 11:06:53 Temperature Measurement, Probe Number = 3, T = 19.976000 C 11:06:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:06:53 Integrated Voltage Measurement... 11:07:12 Voltage Offset Correction: v_off_ini = 0.000001590 V, v_off_fin = 0.000006217 V 11:07:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417935 Vs 11:07:12 Integrated Voltage Measurement... 11:07:31 Voltage Offset Correction: v_off_ini = 0.000005371 V, v_off_fin = -0.000002087 V 11:07:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296364 Vs 11:07:34 Temperature Measurement, Probe Number = 0, T = 20.230000 C 11:07:35 Temperature Measurement, Probe Number = 1, T = 20.038000 C 11:07:35 Temperature Measurement, Probe Number = 2, T = 20.008000 C 11:07:36 Temperature Measurement, Probe Number = 3, T = 19.977000 C 11:07:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:07:36 Integrated Voltage Measurement... 11:07:55 Voltage Offset Correction: v_off_ini = 0.000001133 V, v_off_fin = 0.000006258 V 11:07:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421840 Vs 11:07:55 Integrated Voltage Measurement... 11:08:15 Voltage Offset Correction: v_off_ini = 0.000005261 V, v_off_fin = -0.000001990 V 11:08:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304397 Vs 11:08:18 Temperature Measurement, Probe Number = 0, T = 20.245000 C 11:08:18 Temperature Measurement, Probe Number = 1, T = 20.041000 C 11:08:19 Temperature Measurement, Probe Number = 2, T = 20.011000 C 11:08:20 Temperature Measurement, Probe Number = 3, T = 19.980000 C 11:08:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:08:20 Integrated Voltage Measurement... 11:08:39 Voltage Offset Correction: v_off_ini = 0.000002157 V, v_off_fin = 0.000006443 V 11:08:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425831 Vs 11:08:39 Integrated Voltage Measurement... 11:08:59 Voltage Offset Correction: v_off_ini = 0.000005919 V, v_off_fin = -0.000001369 V 11:08:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287277 Vs 11:09:02 Temperature Measurement, Probe Number = 0, T = 20.264000 C 11:09:02 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:09:03 Temperature Measurement, Probe Number = 2, T = 20.014000 C 11:09:04 Temperature Measurement, Probe Number = 3, T = 19.980000 C 11:09:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:09:04 Integrated Voltage Measurement... 11:09:23 Voltage Offset Correction: v_off_ini = 0.000002291 V, v_off_fin = 0.000006414 V 11:09:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175426032 Vs 11:09:23 Integrated Voltage Measurement... 11:09:43 Voltage Offset Correction: v_off_ini = 0.000005805 V, v_off_fin = -0.000001852 V 11:09:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290360 Vs 11:09:46 Temperature Measurement, Probe Number = 0, T = 20.320000 C 11:09:46 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:09:47 Temperature Measurement, Probe Number = 2, T = 20.014000 C 11:09:48 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:09:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:09:48 Integrated Voltage Measurement... 11:10:07 Voltage Offset Correction: v_off_ini = 0.000001918 V, v_off_fin = 0.000006466 V 11:10:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175426580 Vs 11:10:08 Integrated Voltage Measurement... 11:10:27 Voltage Offset Correction: v_off_ini = 0.000005455 V, v_off_fin = -0.000001132 V 11:10:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289995 Vs 11:10:30 Temperature Measurement, Probe Number = 0, T = 20.387000 C 11:10:31 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:10:31 Temperature Measurement, Probe Number = 2, T = 20.010000 C 11:10:32 Temperature Measurement, Probe Number = 3, T = 19.979000 C 11:10:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:10:32 Integrated Voltage Measurement... 11:10:51 Voltage Offset Correction: v_off_ini = 0.000001741 V, v_off_fin = 0.000006692 V 11:10:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428477 Vs 11:10:52 Integrated Voltage Measurement... 11:11:11 Voltage Offset Correction: v_off_ini = 0.000005880 V, v_off_fin = -0.000001176 V 11:11:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298134 Vs 11:11:14 Temperature Measurement, Probe Number = 0, T = 20.364000 C 11:11:15 Temperature Measurement, Probe Number = 1, T = 20.035000 C 11:11:15 Temperature Measurement, Probe Number = 2, T = 20.006000 C 11:11:16 Temperature Measurement, Probe Number = 3, T = 19.976000 C 11:11:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:11:16 Integrated Voltage Measurement... 11:11:35 Voltage Offset Correction: v_off_ini = 0.000001536 V, v_off_fin = 0.000006170 V 11:11:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422899 Vs 11:11:36 Integrated Voltage Measurement... 11:11:55 Voltage Offset Correction: v_off_ini = 0.000005272 V, v_off_fin = -0.000001043 V 11:11:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293905 Vs 11:11:58 Temperature Measurement, Probe Number = 0, T = 20.346000 C 11:11:59 Temperature Measurement, Probe Number = 1, T = 20.036000 C 11:11:59 Temperature Measurement, Probe Number = 2, T = 20.007000 C 11:12:00 Temperature Measurement, Probe Number = 3, T = 19.976000 C 11:12:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:12:00 Integrated Voltage Measurement... 11:12:19 Voltage Offset Correction: v_off_ini = 0.000001305 V, v_off_fin = 0.000006544 V 11:12:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428627 Vs 11:12:20 Integrated Voltage Measurement... 11:12:39 Voltage Offset Correction: v_off_ini = 0.000005998 V, v_off_fin = -0.000000660 V 11:12:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285958 Vs 11:12:42 Temperature Measurement, Probe Number = 0, T = 20.333000 C 11:12:42 Temperature Measurement, Probe Number = 1, T = 20.037000 C 11:12:43 Temperature Measurement, Probe Number = 2, T = 20.009000 C 11:12:43 Temperature Measurement, Probe Number = 3, T = 19.978000 C 11:12:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 11:12:44 Integrated Voltage Measurement... 11:13:03 Voltage Offset Correction: v_off_ini = 0.000001587 V, v_off_fin = 0.000006184 V 11:13:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425300 Vs 11:13:03 Integrated Voltage Measurement... 11:13:22 Voltage Offset Correction: v_off_ini = 0.000005538 V, v_off_fin = -0.000001786 V 11:13:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294778 Vs 11:43:25 Temperature Measurement, Probe Number = 0, T = 20.249000 C 11:43:26 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:43:26 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:43:27 Temperature Measurement, Probe Number = 3, T = 19.983000 C 11:43:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:43:27 Integrated Voltage Measurement... 11:43:48 Voltage Offset Correction: v_off_ini = 0.000004094 V, v_off_fin = 0.000005007 V 11:43:49 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.159655989 Vs 11:43:49 Integrated Voltage Measurement... 11:44:08 Voltage Offset Correction: v_off_ini = 0.000005480 V, v_off_fin = -0.000002035 V 11:44:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296205 Vs 11:44:11 Temperature Measurement, Probe Number = 0, T = 20.288000 C 11:44:11 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:44:12 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:44:13 Temperature Measurement, Probe Number = 3, T = 19.983000 C 11:44:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:44:13 Integrated Voltage Measurement... 11:44:32 Voltage Offset Correction: v_off_ini = 0.000001884 V, v_off_fin = 0.000005487 V 11:44:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424076 Vs 11:44:32 Integrated Voltage Measurement... 11:44:51 Voltage Offset Correction: v_off_ini = 0.000004889 V, v_off_fin = -0.000002431 V 11:44:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292342 Vs 11:44:54 Temperature Measurement, Probe Number = 0, T = 20.332000 C 11:44:55 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:44:56 Temperature Measurement, Probe Number = 2, T = 20.018000 C 11:44:56 Temperature Measurement, Probe Number = 3, T = 19.985000 C 11:44:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:44:56 Integrated Voltage Measurement... 11:45:15 Voltage Offset Correction: v_off_ini = 0.000001713 V, v_off_fin = 0.000005836 V 11:45:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422671 Vs 11:45:16 Integrated Voltage Measurement... 11:45:35 Voltage Offset Correction: v_off_ini = 0.000005832 V, v_off_fin = -0.000001679 V 11:45:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298591 Vs 11:45:38 Temperature Measurement, Probe Number = 0, T = 20.371000 C 11:45:38 Temperature Measurement, Probe Number = 1, T = 20.041000 C 11:45:39 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:45:40 Temperature Measurement, Probe Number = 3, T = 19.983000 C 11:45:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:45:40 Integrated Voltage Measurement... 11:46:00 Voltage Offset Correction: v_off_ini = 0.000002173 V, v_off_fin = 0.000006532 V 11:46:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424164 Vs 11:46:00 Integrated Voltage Measurement... 11:46:19 Voltage Offset Correction: v_off_ini = 0.000005703 V, v_off_fin = -0.000001182 V 11:46:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289690 Vs 11:46:22 Temperature Measurement, Probe Number = 0, T = 20.404000 C 11:46:23 Temperature Measurement, Probe Number = 1, T = 20.041000 C 11:46:24 Temperature Measurement, Probe Number = 2, T = 20.018000 C 11:46:24 Temperature Measurement, Probe Number = 3, T = 19.985000 C 11:46:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:46:24 Integrated Voltage Measurement... 11:46:44 Voltage Offset Correction: v_off_ini = 0.000001595 V, v_off_fin = 0.000006590 V 11:46:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419357 Vs 11:46:44 Integrated Voltage Measurement... 11:47:03 Voltage Offset Correction: v_off_ini = 0.000005593 V, v_off_fin = -0.000001255 V 11:47:03 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175288097 Vs 11:47:06 Temperature Measurement, Probe Number = 0, T = 20.410000 C 11:47:06 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:47:07 Temperature Measurement, Probe Number = 2, T = 20.019000 C 11:47:08 Temperature Measurement, Probe Number = 3, T = 19.985000 C 11:47:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:47:08 Integrated Voltage Measurement... 11:47:27 Voltage Offset Correction: v_off_ini = 0.000002197 V, v_off_fin = 0.000006067 V 11:47:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427414 Vs 11:47:27 Integrated Voltage Measurement... 11:47:46 Voltage Offset Correction: v_off_ini = 0.000005482 V, v_off_fin = -0.000001096 V 11:47:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289734 Vs 11:47:49 Temperature Measurement, Probe Number = 0, T = 20.374000 C 11:47:50 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:47:50 Temperature Measurement, Probe Number = 2, T = 20.019000 C 11:47:51 Temperature Measurement, Probe Number = 3, T = 19.984000 C 11:47:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:47:51 Integrated Voltage Measurement... 11:48:11 Voltage Offset Correction: v_off_ini = 0.000001547 V, v_off_fin = 0.000006262 V 11:48:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419544 Vs 11:48:11 Integrated Voltage Measurement... 11:48:30 Voltage Offset Correction: v_off_ini = 0.000005863 V, v_off_fin = -0.000001484 V 11:48:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293359 Vs 11:48:33 Temperature Measurement, Probe Number = 0, T = 20.289000 C 11:48:34 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:48:35 Temperature Measurement, Probe Number = 2, T = 20.017000 C 11:48:35 Temperature Measurement, Probe Number = 3, T = 19.985000 C 11:48:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:48:35 Integrated Voltage Measurement... 11:48:55 Voltage Offset Correction: v_off_ini = 0.000001890 V, v_off_fin = 0.000006219 V 11:48:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425695 Vs 11:48:55 Integrated Voltage Measurement... 11:49:14 Voltage Offset Correction: v_off_ini = 0.000005528 V, v_off_fin = -0.000002079 V 11:49:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299495 Vs 11:49:17 Temperature Measurement, Probe Number = 0, T = 20.240000 C 11:49:18 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:49:19 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:49:19 Temperature Measurement, Probe Number = 3, T = 19.985000 C 11:49:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:49:20 Integrated Voltage Measurement... 11:49:39 Voltage Offset Correction: v_off_ini = 0.000001946 V, v_off_fin = 0.000005614 V 11:49:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426876 Vs 11:49:40 Integrated Voltage Measurement... 11:49:59 Voltage Offset Correction: v_off_ini = 0.000005217 V, v_off_fin = -0.000001729 V 11:49:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293951 Vs 11:50:02 Temperature Measurement, Probe Number = 0, T = 20.237000 C 11:50:03 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:50:03 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:50:04 Temperature Measurement, Probe Number = 3, T = 19.983000 C 11:50:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:50:04 Integrated Voltage Measurement... 11:50:24 Voltage Offset Correction: v_off_ini = 0.000001516 V, v_off_fin = 0.000005980 V 11:50:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429527 Vs 11:50:24 Integrated Voltage Measurement... 11:50:43 Voltage Offset Correction: v_off_ini = 0.000005010 V, v_off_fin = -0.000001423 V 11:50:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297048 Vs 12:20:46 Temperature Measurement, Probe Number = 0, T = 20.098000 C 12:20:47 Temperature Measurement, Probe Number = 1, T = 20.038000 C 12:20:47 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:20:48 Temperature Measurement, Probe Number = 3, T = 19.980000 C 12:20:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:20:48 Integrated Voltage Measurement... 12:21:08 Voltage Offset Correction: v_off_ini = 0.000003807 V, v_off_fin = 0.000006103 V 12:21:08 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175523686 Vs 12:21:08 Integrated Voltage Measurement... 12:21:27 Voltage Offset Correction: v_off_ini = 0.000005906 V, v_off_fin = -0.000000824 V 12:21:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289886 Vs 12:21:30 Temperature Measurement, Probe Number = 0, T = 20.149000 C 12:21:31 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:21:32 Temperature Measurement, Probe Number = 2, T = 20.010000 C 12:21:32 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:21:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:21:32 Integrated Voltage Measurement... 12:21:52 Voltage Offset Correction: v_off_ini = 0.000002385 V, v_off_fin = 0.000006705 V 12:21:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425413 Vs 12:21:52 Integrated Voltage Measurement... 12:22:11 Voltage Offset Correction: v_off_ini = 0.000005941 V, v_off_fin = -0.000002281 V 12:22:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284972 Vs 12:22:14 Temperature Measurement, Probe Number = 0, T = 20.182000 C 12:22:15 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:22:15 Temperature Measurement, Probe Number = 2, T = 20.013000 C 12:22:16 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:22:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:22:16 Integrated Voltage Measurement... 12:22:36 Voltage Offset Correction: v_off_ini = 0.000002111 V, v_off_fin = 0.000006251 V 12:22:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424531 Vs 12:22:36 Integrated Voltage Measurement... 12:22:56 Voltage Offset Correction: v_off_ini = 0.000005558 V, v_off_fin = -0.000001492 V 12:22:56 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175287308 Vs 12:22:59 Temperature Measurement, Probe Number = 0, T = 20.237000 C 12:22:59 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:23:00 Temperature Measurement, Probe Number = 2, T = 20.015000 C 12:23:01 Temperature Measurement, Probe Number = 3, T = 19.985000 C 12:23:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 12:23:01 Integrated Voltage Measurement... 12:23:20 Voltage Offset Correction: v_off_ini = 0.000001823 V, v_off_fin = 0.000006576 V 12:23:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418763 Vs 12:23:20 Integrated Voltage Measurement... 12:23:40 Voltage Offset Correction: v_off_ini = 0.000005557 V, v_off_fin = -0.000001468 V 12:23:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288455 Vs 12:23:42 Temperature Measurement, Probe Number = 0, T = 20.247000 C 12:23:43 Temperature Measurement, Probe Number = 1, T = 20.040000 C 12:23:44 Temperature Measurement, Probe Number = 2, T = 20.014000 C 12:23:44 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:23:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:23:45 Integrated Voltage Measurement... 12:24:04 Voltage Offset Correction: v_off_ini = 0.000001164 V, v_off_fin = 0.000006388 V 12:24:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423443 Vs 12:24:04 Integrated Voltage Measurement... 12:24:23 Voltage Offset Correction: v_off_ini = 0.000005917 V, v_off_fin = -0.000001636 V 12:24:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280357 Vs 12:24:26 Temperature Measurement, Probe Number = 0, T = 20.259000 C 12:24:27 Temperature Measurement, Probe Number = 1, T = 20.040000 C 12:24:27 Temperature Measurement, Probe Number = 2, T = 20.010000 C 12:24:28 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:24:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:24:28 Integrated Voltage Measurement... 12:24:47 Voltage Offset Correction: v_off_ini = 0.000001187 V, v_off_fin = 0.000006198 V 12:24:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427328 Vs 12:24:48 Integrated Voltage Measurement... 12:25:07 Voltage Offset Correction: v_off_ini = 0.000005527 V, v_off_fin = -0.000001689 V 12:25:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290449 Vs 12:25:10 Temperature Measurement, Probe Number = 0, T = 20.292000 C 12:25:10 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:25:11 Temperature Measurement, Probe Number = 2, T = 20.011000 C 12:25:12 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:25:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:25:12 Integrated Voltage Measurement... 12:25:32 Voltage Offset Correction: v_off_ini = 0.000001616 V, v_off_fin = 0.000006327 V 12:25:32 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423900 Vs 12:25:32 Integrated Voltage Measurement... 12:25:53 Voltage Offset Correction: v_off_ini = 0.000005849 V, v_off_fin = 0.000000025 V 12:25:53 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175294248 Vs 12:25:56 Temperature Measurement, Probe Number = 0, T = 20.280000 C 12:25:56 Temperature Measurement, Probe Number = 1, T = 20.037000 C 12:25:57 Temperature Measurement, Probe Number = 2, T = 20.011000 C 12:25:58 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:25:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:25:58 Integrated Voltage Measurement... 12:26:17 Voltage Offset Correction: v_off_ini = 0.000002161 V, v_off_fin = 0.000006043 V 12:26:17 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175411142 Vs 12:26:17 Integrated Voltage Measurement... 12:26:36 Voltage Offset Correction: v_off_ini = 0.000005679 V, v_off_fin = -0.000001988 V 12:26:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295513 Vs 12:26:39 Temperature Measurement, Probe Number = 0, T = 20.234000 C 12:26:40 Temperature Measurement, Probe Number = 1, T = 20.039000 C 12:26:41 Temperature Measurement, Probe Number = 2, T = 20.013000 C 12:26:41 Temperature Measurement, Probe Number = 3, T = 19.980000 C 12:26:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:26:41 Integrated Voltage Measurement... 12:27:00 Voltage Offset Correction: v_off_ini = 0.000001627 V, v_off_fin = 0.000006262 V 12:27:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420812 Vs 12:27:01 Integrated Voltage Measurement... 12:27:20 Voltage Offset Correction: v_off_ini = 0.000005527 V, v_off_fin = -0.000002161 V 12:27:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295163 Vs 12:27:23 Temperature Measurement, Probe Number = 0, T = 20.192000 C 12:27:24 Temperature Measurement, Probe Number = 1, T = 20.040000 C 12:27:24 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:27:25 Temperature Measurement, Probe Number = 3, T = 19.980000 C 12:27:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:27:25 Integrated Voltage Measurement... 12:27:44 Voltage Offset Correction: v_off_ini = 0.000001551 V, v_off_fin = 0.000006017 V 12:27:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423070 Vs 12:27:45 Integrated Voltage Measurement... 12:28:04 Voltage Offset Correction: v_off_ini = 0.000005469 V, v_off_fin = -0.000001534 V 12:28:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293684 Vs 12:58:07 Temperature Measurement, Probe Number = 0, T = 20.420000 C 12:58:08 Temperature Measurement, Probe Number = 1, T = 20.054000 C 12:58:08 Temperature Measurement, Probe Number = 2, T = 20.033000 C 12:58:09 Temperature Measurement, Probe Number = 3, T = 19.999000 C 12:58:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 12:58:09 Integrated Voltage Measurement... 12:58:28 Voltage Offset Correction: v_off_ini = 0.000003569 V, v_off_fin = 0.000005897 V 12:58:28 Integrated Voltage Measurement Delta Gap = 0.0040037 m VT = 0.175524270 Vs 12:58:28 Integrated Voltage Measurement... 12:58:48 Voltage Offset Correction: v_off_ini = 0.000005531 V, v_off_fin = -0.000002742 V 12:58:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289310 Vs 12:58:50 Temperature Measurement, Probe Number = 0, T = 20.457000 C 12:58:51 Temperature Measurement, Probe Number = 1, T = 20.054000 C 12:58:52 Temperature Measurement, Probe Number = 2, T = 20.031000 C 12:58:52 Temperature Measurement, Probe Number = 3, T = 19.998000 C 12:58:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 12:58:53 Integrated Voltage Measurement... 12:59:13 Voltage Offset Correction: v_off_ini = 0.000000721 V, v_off_fin = 0.000004536 V 12:59:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175394818 Vs 12:59:13 Integrated Voltage Measurement... 12:59:32 Voltage Offset Correction: v_off_ini = 0.000004473 V, v_off_fin = -0.000001952 V 12:59:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175277218 Vs 12:59:35 Temperature Measurement, Probe Number = 0, T = 20.451000 C 12:59:36 Temperature Measurement, Probe Number = 1, T = 20.052000 C 12:59:37 Temperature Measurement, Probe Number = 2, T = 20.030000 C 12:59:37 Temperature Measurement, Probe Number = 3, T = 19.995000 C 12:59:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 12:59:37 Integrated Voltage Measurement... 12:59:56 Voltage Offset Correction: v_off_ini = 0.000000985 V, v_off_fin = 0.000006233 V 12:59:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175401602 Vs 12:59:57 Integrated Voltage Measurement... 13:00:16 Voltage Offset Correction: v_off_ini = 0.000006338 V, v_off_fin = -0.000002722 V 13:00:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282974 Vs 13:00:19 Temperature Measurement, Probe Number = 0, T = 20.440000 C 13:00:20 Temperature Measurement, Probe Number = 1, T = 20.050000 C 13:00:20 Temperature Measurement, Probe Number = 2, T = 20.029000 C 13:00:21 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:00:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:00:21 Integrated Voltage Measurement... 13:00:40 Voltage Offset Correction: v_off_ini = 0.000001434 V, v_off_fin = 0.000005461 V 13:00:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399135 Vs 13:00:41 Integrated Voltage Measurement... 13:01:00 Voltage Offset Correction: v_off_ini = 0.000004730 V, v_off_fin = -0.000001560 V 13:01:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291749 Vs 13:01:03 Temperature Measurement, Probe Number = 0, T = 20.414000 C 13:01:04 Temperature Measurement, Probe Number = 1, T = 20.052000 C 13:01:04 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:01:05 Temperature Measurement, Probe Number = 3, T = 19.997000 C 13:01:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:01:05 Integrated Voltage Measurement... 13:01:24 Voltage Offset Correction: v_off_ini = 0.000001727 V, v_off_fin = 0.000006457 V 13:01:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408289 Vs 13:01:25 Integrated Voltage Measurement... 13:01:44 Voltage Offset Correction: v_off_ini = 0.000005366 V, v_off_fin = -0.000001963 V 13:01:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274102 Vs 13:01:47 Temperature Measurement, Probe Number = 0, T = 20.375000 C 13:01:48 Temperature Measurement, Probe Number = 1, T = 20.052000 C 13:01:48 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:01:49 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:01:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:01:49 Integrated Voltage Measurement... 13:02:08 Voltage Offset Correction: v_off_ini = 0.000001361 V, v_off_fin = 0.000006572 V 13:02:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402813 Vs 13:02:09 Integrated Voltage Measurement... 13:02:28 Voltage Offset Correction: v_off_ini = 0.000005574 V, v_off_fin = -0.000002110 V 13:02:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279641 Vs 13:02:30 Temperature Measurement, Probe Number = 0, T = 20.407000 C 13:02:31 Temperature Measurement, Probe Number = 1, T = 20.053000 C 13:02:32 Temperature Measurement, Probe Number = 2, T = 20.030000 C 13:02:32 Temperature Measurement, Probe Number = 3, T = 19.997000 C 13:02:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:02:32 Integrated Voltage Measurement... 13:02:52 Voltage Offset Correction: v_off_ini = 0.000001553 V, v_off_fin = 0.000006188 V 13:02:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405678 Vs 13:02:52 Integrated Voltage Measurement... 13:03:11 Voltage Offset Correction: v_off_ini = 0.000005460 V, v_off_fin = -0.000002618 V 13:03:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175277007 Vs 13:03:14 Temperature Measurement, Probe Number = 0, T = 20.419000 C 13:03:14 Temperature Measurement, Probe Number = 1, T = 20.051000 C 13:03:15 Temperature Measurement, Probe Number = 2, T = 20.032000 C 13:03:15 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:03:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:03:16 Integrated Voltage Measurement... 13:03:35 Voltage Offset Correction: v_off_ini = 0.000001536 V, v_off_fin = 0.000005576 V 13:03:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400934 Vs 13:03:35 Integrated Voltage Measurement... 13:03:54 Voltage Offset Correction: v_off_ini = 0.000005147 V, v_off_fin = -0.000002283 V 13:03:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290020 Vs 13:03:57 Temperature Measurement, Probe Number = 0, T = 20.452000 C 13:03:58 Temperature Measurement, Probe Number = 1, T = 20.051000 C 13:03:58 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:03:59 Temperature Measurement, Probe Number = 3, T = 19.997000 C 13:03:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:03:59 Integrated Voltage Measurement... 13:04:18 Voltage Offset Correction: v_off_ini = 0.000001222 V, v_off_fin = 0.000005800 V 13:04:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175394483 Vs 13:04:19 Integrated Voltage Measurement... 13:04:38 Voltage Offset Correction: v_off_ini = 0.000005194 V, v_off_fin = -0.000002633 V 13:04:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274416 Vs 13:04:41 Temperature Measurement, Probe Number = 0, T = 20.465000 C 13:04:41 Temperature Measurement, Probe Number = 1, T = 20.051000 C 13:04:42 Temperature Measurement, Probe Number = 2, T = 20.030000 C 13:04:43 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:04:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:04:43 Integrated Voltage Measurement... 13:05:02 Voltage Offset Correction: v_off_ini = 0.000001877 V, v_off_fin = 0.000006445 V 13:05:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407203 Vs 13:05:02 Integrated Voltage Measurement... 13:05:22 Voltage Offset Correction: v_off_ini = 0.000005496 V, v_off_fin = -0.000001039 V 13:05:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175273776 Vs 13:35:25 Temperature Measurement, Probe Number = 0, T = 20.318000 C 13:35:26 Temperature Measurement, Probe Number = 1, T = 20.053000 C 13:35:26 Temperature Measurement, Probe Number = 2, T = 20.029000 C 13:35:27 Temperature Measurement, Probe Number = 3, T = 19.999000 C 13:35:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:35:27 Integrated Voltage Measurement... 13:35:46 Voltage Offset Correction: v_off_ini = 0.000004243 V, v_off_fin = 0.000006700 V 13:35:46 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175494823 Vs 13:35:47 Integrated Voltage Measurement... 13:36:06 Voltage Offset Correction: v_off_ini = 0.000005569 V, v_off_fin = -0.000001795 V 13:36:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279318 Vs 13:36:08 Temperature Measurement, Probe Number = 0, T = 20.338000 C 13:36:09 Temperature Measurement, Probe Number = 1, T = 20.052000 C 13:36:10 Temperature Measurement, Probe Number = 2, T = 20.028000 C 13:36:11 Temperature Measurement, Probe Number = 3, T = 19.998000 C 13:36:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:36:11 Integrated Voltage Measurement... 13:36:30 Voltage Offset Correction: v_off_ini = 0.000001974 V, v_off_fin = 0.000006263 V 13:36:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409528 Vs 13:36:30 Integrated Voltage Measurement... 13:36:49 Voltage Offset Correction: v_off_ini = 0.000005908 V, v_off_fin = -0.000001177 V 13:36:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279832 Vs 13:36:52 Temperature Measurement, Probe Number = 0, T = 20.345000 C 13:36:53 Temperature Measurement, Probe Number = 1, T = 20.053000 C 13:36:54 Temperature Measurement, Probe Number = 2, T = 20.030000 C 13:36:54 Temperature Measurement, Probe Number = 3, T = 19.998000 C 13:36:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:36:54 Integrated Voltage Measurement... 13:37:13 Voltage Offset Correction: v_off_ini = 0.000001458 V, v_off_fin = 0.000006455 V 13:37:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409852 Vs 13:37:14 Integrated Voltage Measurement... 13:37:33 Voltage Offset Correction: v_off_ini = 0.000005556 V, v_off_fin = -0.000002312 V 13:37:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280487 Vs 13:37:36 Temperature Measurement, Probe Number = 0, T = 20.347000 C 13:37:37 Temperature Measurement, Probe Number = 1, T = 20.055000 C 13:37:37 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:37:38 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:37:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:37:38 Integrated Voltage Measurement... 13:37:57 Voltage Offset Correction: v_off_ini = 0.000000486 V, v_off_fin = 0.000006043 V 13:37:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175404139 Vs 13:37:58 Integrated Voltage Measurement... 13:38:18 Voltage Offset Correction: v_off_ini = 0.000005393 V, v_off_fin = -0.000000342 V 13:38:19 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175278106 Vs 13:38:21 Temperature Measurement, Probe Number = 0, T = 20.326000 C 13:38:22 Temperature Measurement, Probe Number = 1, T = 20.053000 C 13:38:23 Temperature Measurement, Probe Number = 2, T = 20.027000 C 13:38:23 Temperature Measurement, Probe Number = 3, T = 19.997000 C 13:38:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:38:23 Integrated Voltage Measurement... 13:38:43 Voltage Offset Correction: v_off_ini = 0.000001288 V, v_off_fin = 0.000005538 V 13:38:43 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175386249 Vs 13:38:43 Integrated Voltage Measurement... 13:39:03 Voltage Offset Correction: v_off_ini = 0.000004738 V, v_off_fin = -0.000002556 V 13:39:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292119 Vs 13:39:06 Temperature Measurement, Probe Number = 0, T = 20.274000 C 13:39:06 Temperature Measurement, Probe Number = 1, T = 20.058000 C 13:39:07 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:39:08 Temperature Measurement, Probe Number = 3, T = 20.003000 C 13:39:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:39:08 Integrated Voltage Measurement... 13:39:27 Voltage Offset Correction: v_off_ini = 0.000001176 V, v_off_fin = 0.000006888 V 13:39:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405029 Vs 13:39:27 Integrated Voltage Measurement... 13:39:47 Voltage Offset Correction: v_off_ini = 0.000005702 V, v_off_fin = -0.000001477 V 13:39:47 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175283592 Vs 13:39:49 Temperature Measurement, Probe Number = 0, T = 20.327000 C 13:39:50 Temperature Measurement, Probe Number = 1, T = 20.061000 C 13:39:51 Temperature Measurement, Probe Number = 2, T = 20.032000 C 13:39:51 Temperature Measurement, Probe Number = 3, T = 20.006000 C 13:39:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 13:39:52 Integrated Voltage Measurement... 13:40:11 Voltage Offset Correction: v_off_ini = 0.000001239 V, v_off_fin = 0.000006562 V 13:40:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412213 Vs 13:40:11 Integrated Voltage Measurement... 13:40:30 Voltage Offset Correction: v_off_ini = 0.000005880 V, v_off_fin = -0.000002196 V 13:40:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175277302 Vs 13:40:33 Temperature Measurement, Probe Number = 0, T = 20.384000 C 13:40:34 Temperature Measurement, Probe Number = 1, T = 20.058000 C 13:40:34 Temperature Measurement, Probe Number = 2, T = 20.031000 C 13:40:35 Temperature Measurement, Probe Number = 3, T = 20.002000 C 13:40:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:40:35 Integrated Voltage Measurement... 13:40:54 Voltage Offset Correction: v_off_ini = 0.000001832 V, v_off_fin = 0.000006501 V 13:40:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407339 Vs 13:40:54 Integrated Voltage Measurement... 13:41:14 Voltage Offset Correction: v_off_ini = 0.000005735 V, v_off_fin = -0.000001809 V 13:41:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290855 Vs 13:41:17 Temperature Measurement, Probe Number = 0, T = 20.462000 C 13:41:18 Temperature Measurement, Probe Number = 1, T = 20.061000 C 13:41:18 Temperature Measurement, Probe Number = 2, T = 20.034000 C 13:41:19 Temperature Measurement, Probe Number = 3, T = 20.003000 C 13:41:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:41:19 Integrated Voltage Measurement... 13:41:39 Voltage Offset Correction: v_off_ini = 0.000001416 V, v_off_fin = 0.000006293 V 13:41:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175403474 Vs 13:41:39 Integrated Voltage Measurement... 13:41:58 Voltage Offset Correction: v_off_ini = 0.000006075 V, v_off_fin = -0.000002855 V 13:41:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175268890 Vs 13:42:01 Temperature Measurement, Probe Number = 0, T = 20.511000 C 13:42:01 Temperature Measurement, Probe Number = 1, T = 20.060000 C 13:42:02 Temperature Measurement, Probe Number = 2, T = 20.035000 C 13:42:03 Temperature Measurement, Probe Number = 3, T = 20.003000 C 13:42:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 13:42:03 Integrated Voltage Measurement... 13:42:22 Voltage Offset Correction: v_off_ini = 0.000001217 V, v_off_fin = 0.000006685 V 13:42:22 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175417290 Vs 13:42:22 Integrated Voltage Measurement... 13:42:42 Voltage Offset Correction: v_off_ini = 0.000005631 V, v_off_fin = -0.000002010 V 13:42:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290613 Vs 14:12:45 Temperature Measurement, Probe Number = 0, T = 20.407000 C 14:12:46 Temperature Measurement, Probe Number = 1, T = 20.057000 C 14:12:46 Temperature Measurement, Probe Number = 2, T = 20.037000 C 14:12:47 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:12:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 14:12:47 Integrated Voltage Measurement... 14:13:07 Voltage Offset Correction: v_off_ini = 0.000003986 V, v_off_fin = 0.000005680 V 14:13:07 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175509165 Vs 14:13:07 Integrated Voltage Measurement... 14:13:27 Voltage Offset Correction: v_off_ini = 0.000005101 V, v_off_fin = -0.000001414 V 14:13:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175281532 Vs 14:13:30 Temperature Measurement, Probe Number = 0, T = 20.418000 C 14:13:31 Temperature Measurement, Probe Number = 1, T = 20.060000 C 14:13:31 Temperature Measurement, Probe Number = 2, T = 20.039000 C 14:13:32 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:13:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 14:13:32 Integrated Voltage Measurement... 14:13:51 Voltage Offset Correction: v_off_ini = 0.000001853 V, v_off_fin = 0.000005726 V 14:13:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175391736 Vs 14:13:51 Integrated Voltage Measurement... 14:14:11 Voltage Offset Correction: v_off_ini = 0.000005609 V, v_off_fin = -0.000001973 V 14:14:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287410 Vs 14:14:14 Temperature Measurement, Probe Number = 0, T = 20.436000 C 14:14:15 Temperature Measurement, Probe Number = 1, T = 20.061000 C 14:14:15 Temperature Measurement, Probe Number = 2, T = 20.039000 C 14:14:16 Temperature Measurement, Probe Number = 3, T = 20.006000 C 14:14:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:14:16 Integrated Voltage Measurement... 14:14:35 Voltage Offset Correction: v_off_ini = 0.000001538 V, v_off_fin = 0.000006172 V 14:14:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399648 Vs 14:14:36 Integrated Voltage Measurement... 14:14:55 Voltage Offset Correction: v_off_ini = 0.000005484 V, v_off_fin = -0.000001634 V 14:14:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175278341 Vs 14:14:58 Temperature Measurement, Probe Number = 0, T = 20.473000 C 14:14:59 Temperature Measurement, Probe Number = 1, T = 20.061000 C 14:14:59 Temperature Measurement, Probe Number = 2, T = 20.039000 C 14:15:00 Temperature Measurement, Probe Number = 3, T = 20.008000 C 14:15:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:15:00 Integrated Voltage Measurement... 14:15:19 Voltage Offset Correction: v_off_ini = 0.000001853 V, v_off_fin = 0.000006249 V 14:15:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406145 Vs 14:15:20 Integrated Voltage Measurement... 14:15:39 Voltage Offset Correction: v_off_ini = 0.000005328 V, v_off_fin = -0.000001493 V 14:15:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274642 Vs 14:15:41 Temperature Measurement, Probe Number = 0, T = 20.418000 C 14:15:42 Temperature Measurement, Probe Number = 1, T = 20.062000 C 14:15:43 Temperature Measurement, Probe Number = 2, T = 20.040000 C 14:15:43 Temperature Measurement, Probe Number = 3, T = 20.009000 C 14:15:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:15:44 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = 0.000001674 V, v_off_fin = 0.000006755 V 14:16:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415433 Vs 14:16:03 Integrated Voltage Measurement... 14:16:22 Voltage Offset Correction: v_off_ini = 0.000005766 V, v_off_fin = -0.000001715 V 14:16:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274636 Vs 14:16:25 Temperature Measurement, Probe Number = 0, T = 20.370000 C 14:16:26 Temperature Measurement, Probe Number = 1, T = 20.060000 C 14:16:26 Temperature Measurement, Probe Number = 2, T = 20.037000 C 14:16:27 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:16:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 14:16:27 Integrated Voltage Measurement... 14:16:46 Voltage Offset Correction: v_off_ini = 0.000001929 V, v_off_fin = 0.000006220 V 14:16:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410696 Vs 14:16:46 Integrated Voltage Measurement... 14:17:05 Voltage Offset Correction: v_off_ini = 0.000004947 V, v_off_fin = -0.000001953 V 14:17:06 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175280494 Vs 14:17:08 Temperature Measurement, Probe Number = 0, T = 20.409000 C 14:17:09 Temperature Measurement, Probe Number = 1, T = 20.061000 C 14:17:10 Temperature Measurement, Probe Number = 2, T = 20.036000 C 14:17:10 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:17:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 14:17:10 Integrated Voltage Measurement... 14:17:30 Voltage Offset Correction: v_off_ini = 0.000001372 V, v_off_fin = 0.000006460 V 14:17:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409173 Vs 14:17:30 Integrated Voltage Measurement... 14:17:49 Voltage Offset Correction: v_off_ini = 0.000005695 V, v_off_fin = -0.000003058 V 14:17:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175281204 Vs 14:17:52 Temperature Measurement, Probe Number = 0, T = 20.412000 C 14:17:53 Temperature Measurement, Probe Number = 1, T = 20.064000 C 14:17:53 Temperature Measurement, Probe Number = 2, T = 20.038000 C 14:17:54 Temperature Measurement, Probe Number = 3, T = 20.008000 C 14:17:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:17:54 Integrated Voltage Measurement... 14:18:14 Voltage Offset Correction: v_off_ini = 0.000001255 V, v_off_fin = 0.000006175 V 14:18:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404954 Vs 14:18:14 Integrated Voltage Measurement... 14:18:33 Voltage Offset Correction: v_off_ini = 0.000005401 V, v_off_fin = -0.000001923 V 14:18:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175276736 Vs 14:18:36 Temperature Measurement, Probe Number = 0, T = 20.412000 C 14:18:36 Temperature Measurement, Probe Number = 1, T = 20.066000 C 14:18:37 Temperature Measurement, Probe Number = 2, T = 20.040000 C 14:18:37 Temperature Measurement, Probe Number = 3, T = 20.008000 C 14:18:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:18:38 Integrated Voltage Measurement... 14:18:57 Voltage Offset Correction: v_off_ini = 0.000000940 V, v_off_fin = 0.000006017 V 14:18:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405286 Vs 14:18:57 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = 0.000005239 V, v_off_fin = -0.000002558 V 14:19:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283355 Vs 14:19:19 Temperature Measurement, Probe Number = 0, T = 20.439000 C 14:19:20 Temperature Measurement, Probe Number = 1, T = 20.065000 C 14:19:20 Temperature Measurement, Probe Number = 2, T = 20.040000 C 14:19:21 Temperature Measurement, Probe Number = 3, T = 20.007000 C 14:19:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:19:21 Integrated Voltage Measurement... 14:19:40 Voltage Offset Correction: v_off_ini = 0.000001358 V, v_off_fin = 0.000006032 V 14:19:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402497 Vs 14:19:41 Integrated Voltage Measurement... 14:20:00 Voltage Offset Correction: v_off_ini = 0.000005013 V, v_off_fin = -0.000002423 V 14:20:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285453 Vs 14:50:03 Temperature Measurement, Probe Number = 0, T = 20.481000 C 14:50:03 Temperature Measurement, Probe Number = 1, T = 20.073000 C 14:50:04 Temperature Measurement, Probe Number = 2, T = 20.052000 C 14:50:05 Temperature Measurement, Probe Number = 3, T = 20.016000 C 14:50:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:50:05 Integrated Voltage Measurement... 14:50:24 Voltage Offset Correction: v_off_ini = 0.000003959 V, v_off_fin = 0.000005872 V 14:50:24 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175504616 Vs 14:50:24 Integrated Voltage Measurement... 14:50:44 Voltage Offset Correction: v_off_ini = 0.000005191 V, v_off_fin = -0.000001765 V 14:50:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175276579 Vs 14:50:46 Temperature Measurement, Probe Number = 0, T = 20.499000 C 14:50:47 Temperature Measurement, Probe Number = 1, T = 20.074000 C 14:50:48 Temperature Measurement, Probe Number = 2, T = 20.053000 C 14:50:48 Temperature Measurement, Probe Number = 3, T = 20.016000 C 14:50:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:50:48 Integrated Voltage Measurement... 14:51:08 Voltage Offset Correction: v_off_ini = 0.000001108 V, v_off_fin = 0.000005932 V 14:51:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396941 Vs 14:51:08 Integrated Voltage Measurement... 14:51:27 Voltage Offset Correction: v_off_ini = 0.000004874 V, v_off_fin = -0.000002168 V 14:51:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285881 Vs 14:51:30 Temperature Measurement, Probe Number = 0, T = 20.395000 C 14:51:31 Temperature Measurement, Probe Number = 1, T = 20.076000 C 14:51:31 Temperature Measurement, Probe Number = 2, T = 20.053000 C 14:51:32 Temperature Measurement, Probe Number = 3, T = 20.018000 C 14:51:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:51:32 Integrated Voltage Measurement... 14:51:52 Voltage Offset Correction: v_off_ini = 0.000001733 V, v_off_fin = 0.000006098 V 14:51:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175401532 Vs 14:51:52 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 0.000005287 V, v_off_fin = -0.000002916 V 14:52:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288495 Vs 14:52:14 Temperature Measurement, Probe Number = 0, T = 20.422000 C 14:52:15 Temperature Measurement, Probe Number = 1, T = 20.076000 C 14:52:16 Temperature Measurement, Probe Number = 2, T = 20.054000 C 14:52:16 Temperature Measurement, Probe Number = 3, T = 20.018000 C 14:52:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:52:16 Integrated Voltage Measurement... 14:52:36 Voltage Offset Correction: v_off_ini = 0.000001788 V, v_off_fin = 0.000006348 V 14:52:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406650 Vs 14:52:36 Integrated Voltage Measurement... 14:52:55 Voltage Offset Correction: v_off_ini = 0.000005016 V, v_off_fin = -0.000001926 V 14:52:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282260 Vs 14:52:58 Temperature Measurement, Probe Number = 0, T = 20.402000 C 14:52:59 Temperature Measurement, Probe Number = 1, T = 20.070000 C 14:53:00 Temperature Measurement, Probe Number = 2, T = 20.049000 C 14:53:00 Temperature Measurement, Probe Number = 3, T = 20.013000 C 14:53:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 14:53:01 Integrated Voltage Measurement... 14:53:20 Voltage Offset Correction: v_off_ini = 0.000001459 V, v_off_fin = 0.000005768 V 14:53:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409569 Vs 14:53:21 Integrated Voltage Measurement... 14:53:40 Voltage Offset Correction: v_off_ini = 0.000004814 V, v_off_fin = -0.000002577 V 14:53:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175279880 Vs 14:53:43 Temperature Measurement, Probe Number = 0, T = 20.377000 C 14:53:43 Temperature Measurement, Probe Number = 1, T = 20.073000 C 14:53:44 Temperature Measurement, Probe Number = 2, T = 20.050000 C 14:53:45 Temperature Measurement, Probe Number = 3, T = 20.014000 C 14:53:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 14:53:45 Integrated Voltage Measurement... 14:54:04 Voltage Offset Correction: v_off_ini = 0.000001508 V, v_off_fin = 0.000006440 V 14:54:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409542 Vs 14:54:04 Integrated Voltage Measurement... 14:54:24 Voltage Offset Correction: v_off_ini = 0.000005578 V, v_off_fin = -0.000002437 V 14:54:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282861 Vs 14:54:26 Temperature Measurement, Probe Number = 0, T = 20.415000 C 14:54:27 Temperature Measurement, Probe Number = 1, T = 20.074000 C 14:54:28 Temperature Measurement, Probe Number = 2, T = 20.053000 C 14:54:28 Temperature Measurement, Probe Number = 3, T = 20.013000 C 14:54:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 14:54:29 Integrated Voltage Measurement... 14:54:48 Voltage Offset Correction: v_off_ini = 0.000001401 V, v_off_fin = 0.000005748 V 14:54:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175407882 Vs 14:54:48 Integrated Voltage Measurement... 14:55:08 Voltage Offset Correction: v_off_ini = 0.000004654 V, v_off_fin = -0.000002062 V 14:55:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291553 Vs 14:55:10 Temperature Measurement, Probe Number = 0, T = 20.373000 C 14:55:11 Temperature Measurement, Probe Number = 1, T = 20.075000 C 14:55:12 Temperature Measurement, Probe Number = 2, T = 20.054000 C 14:55:12 Temperature Measurement, Probe Number = 3, T = 20.016000 C 14:55:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:55:13 Integrated Voltage Measurement... 14:55:32 Voltage Offset Correction: v_off_ini = 0.000001733 V, v_off_fin = 0.000006825 V 14:55:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411843 Vs 14:55:32 Integrated Voltage Measurement... 14:55:51 Voltage Offset Correction: v_off_ini = 0.000005821 V, v_off_fin = -0.000002364 V 14:55:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274077 Vs 14:55:54 Temperature Measurement, Probe Number = 0, T = 20.359000 C 14:55:55 Temperature Measurement, Probe Number = 1, T = 20.077000 C 14:55:55 Temperature Measurement, Probe Number = 2, T = 20.054000 C 14:55:56 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:55:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 14:55:56 Integrated Voltage Measurement... 14:56:15 Voltage Offset Correction: v_off_ini = 0.000001164 V, v_off_fin = 0.000006547 V 14:56:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411540 Vs 14:56:15 Integrated Voltage Measurement... 14:56:34 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001461 V 14:56:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175277564 Vs 14:56:37 Temperature Measurement, Probe Number = 0, T = 20.427000 C 14:56:38 Temperature Measurement, Probe Number = 1, T = 20.078000 C 14:56:38 Temperature Measurement, Probe Number = 2, T = 20.057000 C 14:56:39 Temperature Measurement, Probe Number = 3, T = 20.018000 C 14:56:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:56:39 Integrated Voltage Measurement... 14:56:58 Voltage Offset Correction: v_off_ini = 0.000000795 V, v_off_fin = 0.000006078 V 14:56:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407313 Vs 14:56:58 Integrated Voltage Measurement... 14:57:18 Voltage Offset Correction: v_off_ini = 0.000005554 V, v_off_fin = -0.000002107 V 14:57:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292587 Vs 15:27:21 Temperature Measurement, Probe Number = 0, T = 20.519000 C 15:27:22 Temperature Measurement, Probe Number = 1, T = 20.087000 C 15:27:22 Temperature Measurement, Probe Number = 2, T = 20.063000 C 15:27:23 Temperature Measurement, Probe Number = 3, T = 20.028000 C 15:27:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 15:27:23 Integrated Voltage Measurement... 15:27:42 Voltage Offset Correction: v_off_ini = 0.000004177 V, v_off_fin = 0.000006266 V 15:27:43 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175509747 Vs 15:27:43 Integrated Voltage Measurement... 15:28:02 Voltage Offset Correction: v_off_ini = 0.000005378 V, v_off_fin = -0.000002098 V 15:28:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286324 Vs 15:28:05 Temperature Measurement, Probe Number = 0, T = 20.509000 C 15:28:06 Temperature Measurement, Probe Number = 1, T = 20.089000 C 15:28:06 Temperature Measurement, Probe Number = 2, T = 20.065000 C 15:28:07 Temperature Measurement, Probe Number = 3, T = 20.029000 C 15:28:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:28:07 Integrated Voltage Measurement... 15:28:26 Voltage Offset Correction: v_off_ini = 0.000001319 V, v_off_fin = 0.000005960 V 15:28:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404297 Vs 15:28:27 Integrated Voltage Measurement... 15:28:46 Voltage Offset Correction: v_off_ini = 0.000005278 V, v_off_fin = -0.000003034 V 15:28:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175275063 Vs 15:28:48 Temperature Measurement, Probe Number = 0, T = 20.480000 C 15:28:49 Temperature Measurement, Probe Number = 1, T = 20.088000 C 15:28:50 Temperature Measurement, Probe Number = 2, T = 20.065000 C 15:28:50 Temperature Measurement, Probe Number = 3, T = 20.028000 C 15:28:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:28:51 Integrated Voltage Measurement... 15:29:10 Voltage Offset Correction: v_off_ini = 0.000001808 V, v_off_fin = 0.000005584 V 15:29:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175398284 Vs 15:29:10 Integrated Voltage Measurement... 15:29:31 Voltage Offset Correction: v_off_ini = 0.000005247 V, v_off_fin = -0.000000797 V 15:29:31 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175278886 Vs 15:29:34 Temperature Measurement, Probe Number = 0, T = 20.411000 C 15:29:34 Temperature Measurement, Probe Number = 1, T = 20.085000 C 15:29:35 Temperature Measurement, Probe Number = 2, T = 20.058000 C 15:29:36 Temperature Measurement, Probe Number = 3, T = 20.022000 C 15:29:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 15:29:36 Integrated Voltage Measurement... 15:29:55 Voltage Offset Correction: v_off_ini = 0.000002223 V, v_off_fin = 0.000006260 V 15:29:56 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175391159 Vs 15:29:56 Integrated Voltage Measurement... 15:30:16 Voltage Offset Correction: v_off_ini = 0.000005176 V, v_off_fin = -0.000001401 V 15:30:16 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175275006 Vs 15:30:19 Temperature Measurement, Probe Number = 0, T = 20.341000 C 15:30:19 Temperature Measurement, Probe Number = 1, T = 20.086000 C 15:30:20 Temperature Measurement, Probe Number = 2, T = 20.059000 C 15:30:21 Temperature Measurement, Probe Number = 3, T = 20.022000 C 15:30:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 15:30:21 Integrated Voltage Measurement... 15:30:40 Voltage Offset Correction: v_off_ini = 0.000002220 V, v_off_fin = 0.000005413 V 15:30:41 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175395221 Vs 15:30:41 Integrated Voltage Measurement... 15:31:00 Voltage Offset Correction: v_off_ini = 0.000005221 V, v_off_fin = -0.000001573 V 15:31:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175280609 Vs 15:31:03 Temperature Measurement, Probe Number = 0, T = 20.299000 C 15:31:04 Temperature Measurement, Probe Number = 1, T = 20.086000 C 15:31:04 Temperature Measurement, Probe Number = 2, T = 20.061000 C 15:31:05 Temperature Measurement, Probe Number = 3, T = 20.025000 C 15:31:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 15:31:05 Integrated Voltage Measurement... 15:31:25 Voltage Offset Correction: v_off_ini = 0.000001973 V, v_off_fin = 0.000005774 V 15:31:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175398503 Vs 15:31:25 Integrated Voltage Measurement... 15:31:44 Voltage Offset Correction: v_off_ini = 0.000005158 V, v_off_fin = -0.000001575 V 15:31:45 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175274617 Vs 15:31:47 Temperature Measurement, Probe Number = 0, T = 20.366000 C 15:31:48 Temperature Measurement, Probe Number = 1, T = 20.086000 C 15:31:49 Temperature Measurement, Probe Number = 2, T = 20.064000 C 15:31:49 Temperature Measurement, Probe Number = 3, T = 20.029000 C 15:31:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 15:31:49 Integrated Voltage Measurement... 15:32:08 Voltage Offset Correction: v_off_ini = 0.000001120 V, v_off_fin = 0.000005605 V 15:32:09 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175396533 Vs 15:32:09 Integrated Voltage Measurement... 15:32:28 Voltage Offset Correction: v_off_ini = 0.000004853 V, v_off_fin = -0.000002372 V 15:32:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282187 Vs 15:32:31 Temperature Measurement, Probe Number = 0, T = 20.384000 C 15:32:32 Temperature Measurement, Probe Number = 1, T = 20.087000 C 15:32:32 Temperature Measurement, Probe Number = 2, T = 20.064000 C 15:32:33 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:32:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 15:32:33 Integrated Voltage Measurement... 15:32:52 Voltage Offset Correction: v_off_ini = 0.000000885 V, v_off_fin = 0.000006145 V 15:32:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175400836 Vs 15:32:52 Integrated Voltage Measurement... 15:33:11 Voltage Offset Correction: v_off_ini = 0.000005186 V, v_off_fin = -0.000002165 V 15:33:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175278817 Vs 15:33:14 Temperature Measurement, Probe Number = 0, T = 20.402000 C 15:33:15 Temperature Measurement, Probe Number = 1, T = 20.087000 C 15:33:16 Temperature Measurement, Probe Number = 2, T = 20.065000 C 15:33:16 Temperature Measurement, Probe Number = 3, T = 20.026000 C 15:33:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:33:17 Integrated Voltage Measurement... 15:33:36 Voltage Offset Correction: v_off_ini = 0.000001543 V, v_off_fin = 0.000006008 V 15:33:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405558 Vs 15:33:36 Integrated Voltage Measurement... 15:33:55 Voltage Offset Correction: v_off_ini = 0.000005360 V, v_off_fin = -0.000002045 V 15:33:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287034 Vs 15:33:58 Temperature Measurement, Probe Number = 0, T = 20.416000 C 15:33:59 Temperature Measurement, Probe Number = 1, T = 20.090000 C 15:33:59 Temperature Measurement, Probe Number = 2, T = 20.067000 C 15:34:00 Temperature Measurement, Probe Number = 3, T = 20.028000 C 15:34:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:34:00 Integrated Voltage Measurement... 15:34:19 Voltage Offset Correction: v_off_ini = 0.000001633 V, v_off_fin = 0.000006007 V 15:34:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408144 Vs 15:34:20 Integrated Voltage Measurement... 15:34:39 Voltage Offset Correction: v_off_ini = 0.000005406 V, v_off_fin = -0.000002296 V 15:34:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175281824 Vs 16:04:42 Temperature Measurement, Probe Number = 0, T = 20.568000 C 16:04:43 Temperature Measurement, Probe Number = 1, T = 20.099000 C 16:04:43 Temperature Measurement, Probe Number = 2, T = 20.076000 C 16:04:44 Temperature Measurement, Probe Number = 3, T = 20.038000 C 16:04:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.57 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:04:44 Integrated Voltage Measurement... 16:05:04 Voltage Offset Correction: v_off_ini = 0.000003983 V, v_off_fin = 0.000006180 V 16:05:04 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175517020 Vs 16:05:04 Integrated Voltage Measurement... 16:05:24 Voltage Offset Correction: v_off_ini = 0.000005302 V, v_off_fin = -0.000002522 V 16:05:24 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175285273 Vs 16:05:26 Temperature Measurement, Probe Number = 0, T = 20.578000 C 16:05:27 Temperature Measurement, Probe Number = 1, T = 20.101000 C 16:05:28 Temperature Measurement, Probe Number = 2, T = 20.076000 C 16:05:28 Temperature Measurement, Probe Number = 3, T = 20.040000 C 16:05:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.58 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:05:29 Integrated Voltage Measurement... 16:05:48 Voltage Offset Correction: v_off_ini = 0.000000905 V, v_off_fin = 0.000006460 V 16:05:48 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175400874 Vs 16:05:48 Integrated Voltage Measurement... 16:06:07 Voltage Offset Correction: v_off_ini = 0.000005564 V, v_off_fin = -0.000001277 V 16:06:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175274665 Vs 16:06:10 Temperature Measurement, Probe Number = 0, T = 20.509000 C 16:06:11 Temperature Measurement, Probe Number = 1, T = 20.101000 C 16:06:11 Temperature Measurement, Probe Number = 2, T = 20.073000 C 16:06:12 Temperature Measurement, Probe Number = 3, T = 20.037000 C 16:06:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:06:12 Integrated Voltage Measurement... 16:06:31 Voltage Offset Correction: v_off_ini = 0.000001389 V, v_off_fin = 0.000005881 V 16:06:32 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175406303 Vs 16:06:32 Integrated Voltage Measurement... 16:06:51 Voltage Offset Correction: v_off_ini = 0.000005698 V, v_off_fin = -0.000003057 V 16:06:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175273688 Vs 16:06:54 Temperature Measurement, Probe Number = 0, T = 20.492000 C 16:06:54 Temperature Measurement, Probe Number = 1, T = 20.099000 C 16:06:55 Temperature Measurement, Probe Number = 2, T = 20.076000 C 16:06:56 Temperature Measurement, Probe Number = 3, T = 20.038000 C 16:06:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:06:56 Integrated Voltage Measurement... 16:07:15 Voltage Offset Correction: v_off_ini = 0.000001953 V, v_off_fin = 0.000005993 V 16:07:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415904 Vs 16:07:16 Integrated Voltage Measurement... 16:07:35 Voltage Offset Correction: v_off_ini = 0.000005832 V, v_off_fin = -0.000001378 V 16:07:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175278798 Vs 16:07:38 Temperature Measurement, Probe Number = 0, T = 20.482000 C 16:07:38 Temperature Measurement, Probe Number = 1, T = 20.100000 C 16:07:39 Temperature Measurement, Probe Number = 2, T = 20.077000 C 16:07:40 Temperature Measurement, Probe Number = 3, T = 20.038000 C 16:07:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:07:40 Integrated Voltage Measurement... 16:07:59 Voltage Offset Correction: v_off_ini = 0.000001350 V, v_off_fin = 0.000005530 V 16:07:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399448 Vs 16:07:59 Integrated Voltage Measurement... 16:08:18 Voltage Offset Correction: v_off_ini = 0.000004896 V, v_off_fin = -0.000002340 V 16:08:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288107 Vs 16:08:21 Temperature Measurement, Probe Number = 0, T = 20.524000 C 16:08:22 Temperature Measurement, Probe Number = 1, T = 20.098000 C 16:08:23 Temperature Measurement, Probe Number = 2, T = 20.078000 C 16:08:23 Temperature Measurement, Probe Number = 3, T = 20.038000 C 16:08:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:08:23 Integrated Voltage Measurement... 16:08:43 Voltage Offset Correction: v_off_ini = 0.000001038 V, v_off_fin = 0.000005232 V 16:08:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402544 Vs 16:08:43 Integrated Voltage Measurement... 16:09:03 Voltage Offset Correction: v_off_ini = 0.000005171 V, v_off_fin = -0.000001143 V 16:09:04 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175281205 Vs 16:09:06 Temperature Measurement, Probe Number = 0, T = 20.524000 C 16:09:07 Temperature Measurement, Probe Number = 1, T = 20.095000 C 16:09:08 Temperature Measurement, Probe Number = 2, T = 20.075000 C 16:09:08 Temperature Measurement, Probe Number = 3, T = 20.034000 C 16:09:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 16:09:09 Integrated Voltage Measurement... 16:09:28 Voltage Offset Correction: v_off_ini = 0.000002197 V, v_off_fin = 0.000005713 V 16:09:28 Integrated Voltage Measurement Delta Gap = 0.0040008 m VT = 0.175390570 Vs 16:09:28 Integrated Voltage Measurement... 16:09:48 Voltage Offset Correction: v_off_ini = 0.000005054 V, v_off_fin = -0.000002400 V 16:09:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290243 Vs 16:09:51 Temperature Measurement, Probe Number = 0, T = 20.562000 C 16:09:51 Temperature Measurement, Probe Number = 1, T = 20.099000 C 16:09:52 Temperature Measurement, Probe Number = 2, T = 20.078000 C 16:09:52 Temperature Measurement, Probe Number = 3, T = 20.040000 C 16:09:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.56 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:09:53 Integrated Voltage Measurement... 16:10:12 Voltage Offset Correction: v_off_ini = 0.000001069 V, v_off_fin = 0.000005800 V 16:10:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175395499 Vs 16:10:12 Integrated Voltage Measurement... 16:10:33 Voltage Offset Correction: v_off_ini = 0.000004717 V, v_off_fin = -0.000001189 V 16:10:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285718 Vs 16:10:36 Temperature Measurement, Probe Number = 0, T = 20.587000 C 16:10:36 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:10:37 Temperature Measurement, Probe Number = 2, T = 20.079000 C 16:10:38 Temperature Measurement, Probe Number = 3, T = 20.040000 C 16:10:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.59 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:10:38 Integrated Voltage Measurement... 16:10:57 Voltage Offset Correction: v_off_ini = 0.000001319 V, v_off_fin = 0.000006534 V 16:10:57 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175388510 Vs 16:10:57 Integrated Voltage Measurement... 16:11:16 Voltage Offset Correction: v_off_ini = 0.000005053 V, v_off_fin = -0.000002424 V 16:11:16 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175272076 Vs 16:11:19 Temperature Measurement, Probe Number = 0, T = 20.579000 C 16:11:20 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:11:20 Temperature Measurement, Probe Number = 2, T = 20.081000 C 16:11:21 Temperature Measurement, Probe Number = 3, T = 20.042000 C 16:11:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.58 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:11:21 Integrated Voltage Measurement... 16:11:40 Voltage Offset Correction: v_off_ini = 0.000001324 V, v_off_fin = 0.000005560 V 16:11:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175401447 Vs 16:11:40 Integrated Voltage Measurement... 16:12:00 Voltage Offset Correction: v_off_ini = 0.000004569 V, v_off_fin = -0.000002268 V 16:12:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282269 Vs 16:42:03 Temperature Measurement, Probe Number = 0, T = 20.522000 C 16:42:04 Temperature Measurement, Probe Number = 1, T = 20.110000 C 16:42:04 Temperature Measurement, Probe Number = 2, T = 20.090000 C 16:42:05 Temperature Measurement, Probe Number = 3, T = 20.049000 C 16:42:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:42:05 Integrated Voltage Measurement... 16:42:25 Voltage Offset Correction: v_off_ini = 0.000004506 V, v_off_fin = 0.000006491 V 16:42:25 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175502710 Vs 16:42:25 Integrated Voltage Measurement... 16:42:44 Voltage Offset Correction: v_off_ini = 0.000005935 V, v_off_fin = -0.000003152 V 16:42:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175268340 Vs 16:42:47 Temperature Measurement, Probe Number = 0, T = 20.541000 C 16:42:48 Temperature Measurement, Probe Number = 1, T = 20.113000 C 16:42:48 Temperature Measurement, Probe Number = 2, T = 20.092000 C 16:42:49 Temperature Measurement, Probe Number = 3, T = 20.051000 C 16:42:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.54 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:42:49 Integrated Voltage Measurement... 16:43:08 Voltage Offset Correction: v_off_ini = 0.000000479 V, v_off_fin = 0.000006035 V 16:43:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400200 Vs 16:43:08 Integrated Voltage Measurement... 16:43:28 Voltage Offset Correction: v_off_ini = 0.000005225 V, v_off_fin = -0.000001846 V 16:43:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283714 Vs 16:43:31 Temperature Measurement, Probe Number = 0, T = 20.562000 C 16:43:31 Temperature Measurement, Probe Number = 1, T = 20.113000 C 16:43:32 Temperature Measurement, Probe Number = 2, T = 20.095000 C 16:43:32 Temperature Measurement, Probe Number = 3, T = 20.050000 C 16:43:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.56 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:43:33 Integrated Voltage Measurement... 16:43:52 Voltage Offset Correction: v_off_ini = 0.000002154 V, v_off_fin = 0.000006206 V 16:43:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175405333 Vs 16:43:52 Integrated Voltage Measurement... 16:44:12 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001256 V 16:44:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284540 Vs 16:44:15 Temperature Measurement, Probe Number = 0, T = 20.554000 C 16:44:16 Temperature Measurement, Probe Number = 1, T = 20.112000 C 16:44:16 Temperature Measurement, Probe Number = 2, T = 20.095000 C 16:44:17 Temperature Measurement, Probe Number = 3, T = 20.052000 C 16:44:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.55 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:44:17 Integrated Voltage Measurement... 16:44:36 Voltage Offset Correction: v_off_ini = 0.000001402 V, v_off_fin = 0.000006554 V 16:44:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175403439 Vs 16:44:37 Integrated Voltage Measurement... 16:44:56 Voltage Offset Correction: v_off_ini = 0.000005382 V, v_off_fin = -0.000001841 V 16:44:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283758 Vs 16:44:59 Temperature Measurement, Probe Number = 0, T = 20.538000 C 16:44:59 Temperature Measurement, Probe Number = 1, T = 20.112000 C 16:45:00 Temperature Measurement, Probe Number = 2, T = 20.093000 C 16:45:01 Temperature Measurement, Probe Number = 3, T = 20.052000 C 16:45:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.54 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:45:01 Integrated Voltage Measurement... 16:45:20 Voltage Offset Correction: v_off_ini = 0.000001838 V, v_off_fin = 0.000005839 V 16:45:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402421 Vs 16:45:20 Integrated Voltage Measurement... 16:45:39 Voltage Offset Correction: v_off_ini = 0.000005329 V, v_off_fin = -0.000002160 V 16:45:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175285730 Vs 16:45:42 Temperature Measurement, Probe Number = 0, T = 20.519000 C 16:45:43 Temperature Measurement, Probe Number = 1, T = 20.114000 C 16:45:44 Temperature Measurement, Probe Number = 2, T = 20.094000 C 16:45:44 Temperature Measurement, Probe Number = 3, T = 20.052000 C 16:45:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:45:44 Integrated Voltage Measurement... 16:46:03 Voltage Offset Correction: v_off_ini = 0.000001218 V, v_off_fin = 0.000006829 V 16:46:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406933 Vs 16:46:04 Integrated Voltage Measurement... 16:46:23 Voltage Offset Correction: v_off_ini = 0.000005019 V, v_off_fin = -0.000002650 V 16:46:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289558 Vs 16:46:26 Temperature Measurement, Probe Number = 0, T = 20.513000 C 16:46:27 Temperature Measurement, Probe Number = 1, T = 20.113000 C 16:46:28 Temperature Measurement, Probe Number = 2, T = 20.092000 C 16:46:28 Temperature Measurement, Probe Number = 3, T = 20.050000 C 16:46:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:46:28 Integrated Voltage Measurement... 16:46:47 Voltage Offset Correction: v_off_ini = 0.000001566 V, v_off_fin = 0.000005408 V 16:46:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175397503 Vs 16:46:48 Integrated Voltage Measurement... 16:47:07 Voltage Offset Correction: v_off_ini = 0.000004947 V, v_off_fin = -0.000002074 V 16:47:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297508 Vs 16:47:10 Temperature Measurement, Probe Number = 0, T = 20.438000 C 16:47:10 Temperature Measurement, Probe Number = 1, T = 20.110000 C 16:47:11 Temperature Measurement, Probe Number = 2, T = 20.089000 C 16:47:12 Temperature Measurement, Probe Number = 3, T = 20.046000 C 16:47:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:47:12 Integrated Voltage Measurement... 16:47:31 Voltage Offset Correction: v_off_ini = 0.000000851 V, v_off_fin = 0.000006073 V 16:47:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407232 Vs 16:47:31 Integrated Voltage Measurement... 16:47:51 Voltage Offset Correction: v_off_ini = 0.000005733 V, v_off_fin = -0.000001700 V 16:47:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289763 Vs 16:47:53 Temperature Measurement, Probe Number = 0, T = 20.355000 C 16:47:54 Temperature Measurement, Probe Number = 1, T = 20.109000 C 16:47:55 Temperature Measurement, Probe Number = 2, T = 20.087000 C 16:47:55 Temperature Measurement, Probe Number = 3, T = 20.045000 C 16:47:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:47:56 Integrated Voltage Measurement... 16:48:15 Voltage Offset Correction: v_off_ini = 0.000000706 V, v_off_fin = 0.000006115 V 16:48:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404545 Vs 16:48:15 Integrated Voltage Measurement... 16:48:34 Voltage Offset Correction: v_off_ini = 0.000005382 V, v_off_fin = -0.000001719 V 16:48:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289334 Vs 16:48:37 Temperature Measurement, Probe Number = 0, T = 20.290000 C 16:48:38 Temperature Measurement, Probe Number = 1, T = 20.111000 C 16:48:39 Temperature Measurement, Probe Number = 2, T = 20.091000 C 16:48:39 Temperature Measurement, Probe Number = 3, T = 20.047000 C 16:48:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 16:48:40 Integrated Voltage Measurement... 16:48:59 Voltage Offset Correction: v_off_ini = 0.000002221 V, v_off_fin = 0.000006044 V 16:48:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407307 Vs 16:48:59 Integrated Voltage Measurement... 16:49:19 Voltage Offset Correction: v_off_ini = 0.000004968 V, v_off_fin = -0.000000851 V 16:49:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292353 Vs 17:19:22 Temperature Measurement, Probe Number = 0, T = 20.273000 C 17:19:22 Temperature Measurement, Probe Number = 1, T = 20.107000 C 17:19:23 Temperature Measurement, Probe Number = 2, T = 20.084000 C 17:19:23 Temperature Measurement, Probe Number = 3, T = 20.044000 C 17:19:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:19:24 Integrated Voltage Measurement... 17:19:43 Voltage Offset Correction: v_off_ini = 0.000003833 V, v_off_fin = 0.000006010 V 17:19:44 Integrated Voltage Measurement Delta Gap = 0.0040026 m VT = 0.175491654 Vs 17:19:44 Integrated Voltage Measurement... 17:20:03 Voltage Offset Correction: v_off_ini = 0.000004725 V, v_off_fin = -0.000001671 V 17:20:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300745 Vs 17:20:06 Temperature Measurement, Probe Number = 0, T = 20.280000 C 17:20:07 Temperature Measurement, Probe Number = 1, T = 20.113000 C 17:20:07 Temperature Measurement, Probe Number = 2, T = 20.089000 C 17:20:08 Temperature Measurement, Probe Number = 3, T = 20.050000 C 17:20:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:20:08 Integrated Voltage Measurement... 17:20:27 Voltage Offset Correction: v_off_ini = 0.000000753 V, v_off_fin = 0.000005897 V 17:20:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413443 Vs 17:20:28 Integrated Voltage Measurement... 17:20:47 Voltage Offset Correction: v_off_ini = 0.000005187 V, v_off_fin = -0.000002597 V 17:20:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295336 Vs 17:20:50 Temperature Measurement, Probe Number = 0, T = 20.337000 C 17:20:51 Temperature Measurement, Probe Number = 1, T = 20.112000 C 17:20:51 Temperature Measurement, Probe Number = 2, T = 20.088000 C 17:20:52 Temperature Measurement, Probe Number = 3, T = 20.051000 C 17:20:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:20:52 Integrated Voltage Measurement... 17:21:12 Voltage Offset Correction: v_off_ini = 0.000001119 V, v_off_fin = 0.000005671 V 17:21:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411423 Vs 17:21:12 Integrated Voltage Measurement... 17:21:31 Voltage Offset Correction: v_off_ini = 0.000005146 V, v_off_fin = -0.000001645 V 17:21:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295797 Vs 17:21:34 Temperature Measurement, Probe Number = 0, T = 20.364000 C 17:21:35 Temperature Measurement, Probe Number = 1, T = 20.112000 C 17:21:35 Temperature Measurement, Probe Number = 2, T = 20.091000 C 17:21:36 Temperature Measurement, Probe Number = 3, T = 20.049000 C 17:21:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:21:36 Integrated Voltage Measurement... 17:21:57 Voltage Offset Correction: v_off_ini = 0.000001075 V, v_off_fin = 0.000004991 V 17:21:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414905 Vs 17:21:58 Integrated Voltage Measurement... 17:22:17 Voltage Offset Correction: v_off_ini = 0.000004784 V, v_off_fin = -0.000002659 V 17:22:17 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285658 Vs 17:22:20 Temperature Measurement, Probe Number = 0, T = 20.364000 C 17:22:20 Temperature Measurement, Probe Number = 1, T = 20.116000 C 17:22:21 Temperature Measurement, Probe Number = 2, T = 20.091000 C 17:22:22 Temperature Measurement, Probe Number = 3, T = 20.053000 C 17:22:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:22:22 Integrated Voltage Measurement... 17:22:41 Voltage Offset Correction: v_off_ini = 0.000001030 V, v_off_fin = 0.000006368 V 17:22:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412127 Vs 17:22:41 Integrated Voltage Measurement... 17:23:00 Voltage Offset Correction: v_off_ini = 0.000005700 V, v_off_fin = -0.000002639 V 17:23:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293210 Vs 17:23:03 Temperature Measurement, Probe Number = 0, T = 20.345000 C 17:23:04 Temperature Measurement, Probe Number = 1, T = 20.109000 C 17:23:05 Temperature Measurement, Probe Number = 2, T = 20.087000 C 17:23:05 Temperature Measurement, Probe Number = 3, T = 20.048000 C 17:23:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:23:05 Integrated Voltage Measurement... 17:23:25 Voltage Offset Correction: v_off_ini = 0.000000999 V, v_off_fin = 0.000005946 V 17:23:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421066 Vs 17:23:25 Integrated Voltage Measurement... 17:23:44 Voltage Offset Correction: v_off_ini = 0.000005223 V, v_off_fin = -0.000001993 V 17:23:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300766 Vs 17:23:47 Temperature Measurement, Probe Number = 0, T = 20.371000 C 17:23:48 Temperature Measurement, Probe Number = 1, T = 20.108000 C 17:23:49 Temperature Measurement, Probe Number = 2, T = 20.088000 C 17:23:49 Temperature Measurement, Probe Number = 3, T = 20.047000 C 17:23:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:23:49 Integrated Voltage Measurement... 17:24:09 Voltage Offset Correction: v_off_ini = 0.000001327 V, v_off_fin = 0.000005931 V 17:24:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415965 Vs 17:24:09 Integrated Voltage Measurement... 17:24:28 Voltage Offset Correction: v_off_ini = 0.000005723 V, v_off_fin = -0.000001586 V 17:24:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292350 Vs 17:24:31 Temperature Measurement, Probe Number = 0, T = 20.391000 C 17:24:32 Temperature Measurement, Probe Number = 1, T = 20.113000 C 17:24:33 Temperature Measurement, Probe Number = 2, T = 20.091000 C 17:24:33 Temperature Measurement, Probe Number = 3, T = 20.052000 C 17:24:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:24:33 Integrated Voltage Measurement... 17:24:53 Voltage Offset Correction: v_off_ini = 0.000001971 V, v_off_fin = 0.000005996 V 17:24:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413001 Vs 17:24:53 Integrated Voltage Measurement... 17:25:13 Voltage Offset Correction: v_off_ini = 0.000005444 V, v_off_fin = -0.000002005 V 17:25:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293228 Vs 17:25:15 Temperature Measurement, Probe Number = 0, T = 20.424000 C 17:25:16 Temperature Measurement, Probe Number = 1, T = 20.113000 C 17:25:17 Temperature Measurement, Probe Number = 2, T = 20.086000 C 17:25:17 Temperature Measurement, Probe Number = 3, T = 20.049000 C 17:25:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:25:18 Integrated Voltage Measurement... 17:25:37 Voltage Offset Correction: v_off_ini = 0.000001386 V, v_off_fin = 0.000006033 V 17:25:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414643 Vs 17:25:37 Integrated Voltage Measurement... 17:25:57 Voltage Offset Correction: v_off_ini = 0.000005292 V, v_off_fin = -0.000001345 V 17:25:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296554 Vs 17:26:00 Temperature Measurement, Probe Number = 0, T = 20.385000 C 17:26:00 Temperature Measurement, Probe Number = 1, T = 20.111000 C 17:26:01 Temperature Measurement, Probe Number = 2, T = 20.088000 C 17:26:01 Temperature Measurement, Probe Number = 3, T = 20.050000 C 17:26:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:26:02 Integrated Voltage Measurement... 17:26:21 Voltage Offset Correction: v_off_ini = 0.000001408 V, v_off_fin = 0.000005919 V 17:26:21 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417484 Vs 17:26:21 Integrated Voltage Measurement... 17:26:41 Voltage Offset Correction: v_off_ini = 0.000005094 V, v_off_fin = -0.000002090 V 17:26:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302534 Vs 17:56:44 Temperature Measurement, Probe Number = 0, T = 20.281000 C 17:56:44 Temperature Measurement, Probe Number = 1, T = 20.117000 C 17:56:45 Temperature Measurement, Probe Number = 2, T = 20.092000 C 17:56:46 Temperature Measurement, Probe Number = 3, T = 20.053000 C 17:56:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:56:46 Integrated Voltage Measurement... 17:57:05 Voltage Offset Correction: v_off_ini = 0.000003594 V, v_off_fin = 0.000005505 V 17:57:05 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175511776 Vs 17:57:05 Integrated Voltage Measurement... 17:57:25 Voltage Offset Correction: v_off_ini = 0.000005597 V, v_off_fin = -0.000001493 V 17:57:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175287232 Vs 17:57:27 Temperature Measurement, Probe Number = 0, T = 20.315000 C 17:57:28 Temperature Measurement, Probe Number = 1, T = 20.120000 C 17:57:29 Temperature Measurement, Probe Number = 2, T = 20.096000 C 17:57:29 Temperature Measurement, Probe Number = 3, T = 20.053000 C 17:57:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.10 P3 = Top 1, Value = 20.05 17:57:30 Integrated Voltage Measurement... 17:57:49 Voltage Offset Correction: v_off_ini = 0.000000199 V, v_off_fin = 0.000005737 V 17:57:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175407373 Vs 17:57:49 Integrated Voltage Measurement... 17:58:09 Voltage Offset Correction: v_off_ini = 0.000004862 V, v_off_fin = -0.000002921 V 17:58:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290687 Vs 17:58:12 Temperature Measurement, Probe Number = 0, T = 20.330000 C 17:58:12 Temperature Measurement, Probe Number = 1, T = 20.120000 C 17:58:13 Temperature Measurement, Probe Number = 2, T = 20.096000 C 17:58:13 Temperature Measurement, Probe Number = 3, T = 20.051000 C 17:58:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.10 P3 = Top 1, Value = 20.05 17:58:14 Integrated Voltage Measurement... 17:58:33 Voltage Offset Correction: v_off_ini = 0.000001709 V, v_off_fin = 0.000005731 V 17:58:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175408408 Vs 17:58:33 Integrated Voltage Measurement... 17:58:53 Voltage Offset Correction: v_off_ini = 0.000005132 V, v_off_fin = -0.000002122 V 17:58:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289524 Vs 17:58:56 Temperature Measurement, Probe Number = 0, T = 20.334000 C 17:58:56 Temperature Measurement, Probe Number = 1, T = 20.114000 C 17:58:57 Temperature Measurement, Probe Number = 2, T = 20.087000 C 17:58:58 Temperature Measurement, Probe Number = 3, T = 20.046000 C 17:58:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:58:58 Integrated Voltage Measurement... 17:59:17 Voltage Offset Correction: v_off_ini = 0.000001697 V, v_off_fin = 0.000005632 V 17:59:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175407469 Vs 17:59:17 Integrated Voltage Measurement... 17:59:36 Voltage Offset Correction: v_off_ini = 0.000004915 V, v_off_fin = -0.000002082 V 17:59:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293231 Vs 17:59:39 Temperature Measurement, Probe Number = 0, T = 20.298000 C 17:59:40 Temperature Measurement, Probe Number = 1, T = 20.113000 C 17:59:40 Temperature Measurement, Probe Number = 2, T = 20.088000 C 17:59:41 Temperature Measurement, Probe Number = 3, T = 20.046000 C 17:59:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 17:59:41 Integrated Voltage Measurement... 18:00:00 Voltage Offset Correction: v_off_ini = 0.000001732 V, v_off_fin = 0.000005952 V 18:00:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413267 Vs 18:00:01 Integrated Voltage Measurement... 18:00:20 Voltage Offset Correction: v_off_ini = 0.000005331 V, v_off_fin = -0.000001845 V 18:00:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290537 Vs 18:00:23 Temperature Measurement, Probe Number = 0, T = 20.277000 C 18:00:24 Temperature Measurement, Probe Number = 1, T = 20.114000 C 18:00:24 Temperature Measurement, Probe Number = 2, T = 20.090000 C 18:00:25 Temperature Measurement, Probe Number = 3, T = 20.051000 C 18:00:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:00:25 Integrated Voltage Measurement... 18:00:44 Voltage Offset Correction: v_off_ini = 0.000001181 V, v_off_fin = 0.000005722 V 18:00:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409898 Vs 18:00:44 Integrated Voltage Measurement... 18:01:04 Voltage Offset Correction: v_off_ini = 0.000005326 V, v_off_fin = -0.000003076 V 18:01:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296213 Vs 18:01:07 Temperature Measurement, Probe Number = 0, T = 20.329000 C 18:01:08 Temperature Measurement, Probe Number = 1, T = 20.118000 C 18:01:08 Temperature Measurement, Probe Number = 2, T = 20.096000 C 18:01:09 Temperature Measurement, Probe Number = 3, T = 20.056000 C 18:01:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.10 P3 = Top 1, Value = 20.06 18:01:09 Integrated Voltage Measurement... 18:01:28 Voltage Offset Correction: v_off_ini = 0.000001923 V, v_off_fin = 0.000006137 V 18:01:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415361 Vs 18:01:29 Integrated Voltage Measurement... 18:01:48 Voltage Offset Correction: v_off_ini = 0.000005618 V, v_off_fin = -0.000002452 V 18:01:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295741 Vs 18:01:51 Temperature Measurement, Probe Number = 0, T = 20.361000 C 18:01:51 Temperature Measurement, Probe Number = 1, T = 20.118000 C 18:01:52 Temperature Measurement, Probe Number = 2, T = 20.096000 C 18:01:53 Temperature Measurement, Probe Number = 3, T = 20.056000 C 18:01:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.10 P3 = Top 1, Value = 20.06 18:01:53 Integrated Voltage Measurement... 18:02:12 Voltage Offset Correction: v_off_ini = 0.000001233 V, v_off_fin = 0.000005655 V 18:02:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175415518 Vs 18:02:12 Integrated Voltage Measurement... 18:02:32 Voltage Offset Correction: v_off_ini = 0.000005633 V, v_off_fin = -0.000001510 V 18:02:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288406 Vs 18:02:34 Temperature Measurement, Probe Number = 0, T = 20.401000 C 18:02:35 Temperature Measurement, Probe Number = 1, T = 20.121000 C 18:02:36 Temperature Measurement, Probe Number = 2, T = 20.093000 C 18:02:36 Temperature Measurement, Probe Number = 3, T = 20.052000 C 18:02:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:02:36 Integrated Voltage Measurement... 18:02:55 Voltage Offset Correction: v_off_ini = 0.000001816 V, v_off_fin = 0.000006019 V 18:02:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412719 Vs 18:02:56 Integrated Voltage Measurement... 18:03:15 Voltage Offset Correction: v_off_ini = 0.000005614 V, v_off_fin = -0.000001607 V 18:03:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294461 Vs 18:03:18 Temperature Measurement, Probe Number = 0, T = 20.392000 C 18:03:19 Temperature Measurement, Probe Number = 1, T = 20.120000 C 18:03:19 Temperature Measurement, Probe Number = 2, T = 20.091000 C 18:03:20 Temperature Measurement, Probe Number = 3, T = 20.051000 C 18:03:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:03:20 Integrated Voltage Measurement... 18:03:39 Voltage Offset Correction: v_off_ini = 0.000001538 V, v_off_fin = 0.000005920 V 18:03:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175410796 Vs 18:03:40 Integrated Voltage Measurement... 18:03:58 Voltage Offset Correction: v_off_ini = 0.000005270 V, v_off_fin = -0.000002004 V 18:03:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290354 Vs 18:34:01 Temperature Measurement, Probe Number = 0, T = 20.303000 C 18:34:02 Temperature Measurement, Probe Number = 1, T = 20.115000 C 18:34:03 Temperature Measurement, Probe Number = 2, T = 20.093000 C 18:34:04 Temperature Measurement, Probe Number = 3, T = 20.052000 C 18:34:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:34:04 Integrated Voltage Measurement... 18:34:23 Voltage Offset Correction: v_off_ini = 0.000004150 V, v_off_fin = 0.000006117 V 18:34:24 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175504988 Vs 18:34:24 Integrated Voltage Measurement... 18:34:43 Voltage Offset Correction: v_off_ini = 0.000005750 V, v_off_fin = -0.000001560 V 18:34:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301456 Vs 18:34:46 Temperature Measurement, Probe Number = 0, T = 20.313000 C 18:34:47 Temperature Measurement, Probe Number = 1, T = 20.117000 C 18:34:48 Temperature Measurement, Probe Number = 2, T = 20.093000 C 18:34:48 Temperature Measurement, Probe Number = 3, T = 20.053000 C 18:34:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:34:48 Integrated Voltage Measurement... 18:35:07 Voltage Offset Correction: v_off_ini = 0.000002068 V, v_off_fin = 0.000006261 V 18:35:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422552 Vs 18:35:08 Integrated Voltage Measurement... 18:35:27 Voltage Offset Correction: v_off_ini = 0.000005563 V, v_off_fin = -0.000001606 V 18:35:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293705 Vs 18:35:30 Temperature Measurement, Probe Number = 0, T = 20.284000 C 18:35:31 Temperature Measurement, Probe Number = 1, T = 20.116000 C 18:35:31 Temperature Measurement, Probe Number = 2, T = 20.089000 C 18:35:32 Temperature Measurement, Probe Number = 3, T = 20.055000 C 18:35:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.12 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:35:32 Integrated Voltage Measurement... 18:35:51 Voltage Offset Correction: v_off_ini = 0.000002148 V, v_off_fin = 0.000006511 V 18:35:52 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427426 Vs 18:35:52 Integrated Voltage Measurement... 18:36:11 Voltage Offset Correction: v_off_ini = 0.000005359 V, v_off_fin = -0.000001278 V 18:36:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300785 Vs 18:36:14 Temperature Measurement, Probe Number = 0, T = 20.262000 C 18:36:15 Temperature Measurement, Probe Number = 1, T = 20.109000 C 18:36:15 Temperature Measurement, Probe Number = 2, T = 20.082000 C 18:36:16 Temperature Measurement, Probe Number = 3, T = 20.045000 C 18:36:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:36:16 Integrated Voltage Measurement... 18:36:36 Voltage Offset Correction: v_off_ini = 0.000001791 V, v_off_fin = 0.000006763 V 18:36:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434920 Vs 18:36:36 Integrated Voltage Measurement... 18:36:55 Voltage Offset Correction: v_off_ini = 0.000005926 V, v_off_fin = -0.000001362 V 18:36:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289757 Vs 18:36:58 Temperature Measurement, Probe Number = 0, T = 20.310000 C 18:36:59 Temperature Measurement, Probe Number = 1, T = 20.113000 C 18:36:59 Temperature Measurement, Probe Number = 2, T = 20.084000 C 18:37:00 Temperature Measurement, Probe Number = 3, T = 20.048000 C 18:37:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:37:00 Integrated Voltage Measurement... 18:37:19 Voltage Offset Correction: v_off_ini = 0.000001568 V, v_off_fin = 0.000006383 V 18:37:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432688 Vs 18:37:20 Integrated Voltage Measurement... 18:37:39 Voltage Offset Correction: v_off_ini = 0.000005708 V, v_off_fin = -0.000001846 V 18:37:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175288323 Vs 18:37:42 Temperature Measurement, Probe Number = 0, T = 20.350000 C 18:37:42 Temperature Measurement, Probe Number = 1, T = 20.112000 C 18:37:43 Temperature Measurement, Probe Number = 2, T = 20.089000 C 18:37:44 Temperature Measurement, Probe Number = 3, T = 20.048000 C 18:37:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:37:44 Integrated Voltage Measurement... 18:38:03 Voltage Offset Correction: v_off_ini = 0.000001671 V, v_off_fin = 0.000006401 V 18:38:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435270 Vs 18:38:04 Integrated Voltage Measurement... 18:38:23 Voltage Offset Correction: v_off_ini = 0.000005735 V, v_off_fin = -0.000001558 V 18:38:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291722 Vs 18:38:26 Temperature Measurement, Probe Number = 0, T = 20.329000 C 18:38:26 Temperature Measurement, Probe Number = 1, T = 20.113000 C 18:38:27 Temperature Measurement, Probe Number = 2, T = 20.088000 C 18:38:28 Temperature Measurement, Probe Number = 3, T = 20.050000 C 18:38:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:38:28 Integrated Voltage Measurement... 18:38:48 Voltage Offset Correction: v_off_ini = 0.000001099 V, v_off_fin = 0.000006129 V 18:38:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435829 Vs 18:38:48 Integrated Voltage Measurement... 18:39:07 Voltage Offset Correction: v_off_ini = 0.000004909 V, v_off_fin = -0.000001734 V 18:39:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304432 Vs 18:39:10 Temperature Measurement, Probe Number = 0, T = 20.263000 C 18:39:11 Temperature Measurement, Probe Number = 1, T = 20.109000 C 18:39:11 Temperature Measurement, Probe Number = 2, T = 20.085000 C 18:39:12 Temperature Measurement, Probe Number = 3, T = 20.045000 C 18:39:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:39:12 Integrated Voltage Measurement... 18:39:32 Voltage Offset Correction: v_off_ini = 0.000001456 V, v_off_fin = 0.000005902 V 18:39:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424785 Vs 18:39:32 Integrated Voltage Measurement... 18:39:51 Voltage Offset Correction: v_off_ini = 0.000004858 V, v_off_fin = -0.000002059 V 18:39:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314167 Vs 18:39:54 Temperature Measurement, Probe Number = 0, T = 20.290000 C 18:39:55 Temperature Measurement, Probe Number = 1, T = 20.114000 C 18:39:56 Temperature Measurement, Probe Number = 2, T = 20.089000 C 18:39:56 Temperature Measurement, Probe Number = 3, T = 20.050000 C 18:39:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 18:39:56 Integrated Voltage Measurement... 18:40:16 Voltage Offset Correction: v_off_ini = 0.000001117 V, v_off_fin = 0.000006546 V 18:40:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429536 Vs 18:40:16 Integrated Voltage Measurement... 18:40:35 Voltage Offset Correction: v_off_ini = 0.000005805 V, v_off_fin = -0.000002072 V 18:40:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294937 Vs 18:40:38 Temperature Measurement, Probe Number = 0, T = 20.272000 C 18:40:38 Temperature Measurement, Probe Number = 1, T = 20.112000 C 18:40:39 Temperature Measurement, Probe Number = 2, T = 20.084000 C 18:40:40 Temperature Measurement, Probe Number = 3, T = 20.047000 C 18:40:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:40:40 Integrated Voltage Measurement... 18:40:59 Voltage Offset Correction: v_off_ini = 0.000001125 V, v_off_fin = 0.000006737 V 18:40:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436023 Vs 18:40:59 Integrated Voltage Measurement... 18:41:19 Voltage Offset Correction: v_off_ini = 0.000005792 V, v_off_fin = -0.000001241 V 18:41:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296467 Vs 19:11:22 Temperature Measurement, Probe Number = 0, T = 20.254000 C 19:11:22 Temperature Measurement, Probe Number = 1, T = 20.106000 C 19:11:23 Temperature Measurement, Probe Number = 2, T = 20.077000 C 19:11:23 Temperature Measurement, Probe Number = 3, T = 20.040000 C 19:11:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:11:24 Integrated Voltage Measurement... 19:11:43 Voltage Offset Correction: v_off_ini = 0.000004826 V, v_off_fin = 0.000006237 V 19:11:43 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175515373 Vs 19:11:43 Integrated Voltage Measurement... 19:12:02 Voltage Offset Correction: v_off_ini = 0.000005728 V, v_off_fin = -0.000001489 V 19:12:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303647 Vs 19:12:05 Temperature Measurement, Probe Number = 0, T = 20.241000 C 19:12:06 Temperature Measurement, Probe Number = 1, T = 20.107000 C 19:12:07 Temperature Measurement, Probe Number = 2, T = 20.080000 C 19:12:07 Temperature Measurement, Probe Number = 3, T = 20.043000 C 19:12:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:12:07 Integrated Voltage Measurement... 19:12:26 Voltage Offset Correction: v_off_ini = 0.000002809 V, v_off_fin = 0.000006387 V 19:12:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432967 Vs 19:12:27 Integrated Voltage Measurement... 19:12:46 Voltage Offset Correction: v_off_ini = 0.000005906 V, v_off_fin = -0.000002227 V 19:12:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296588 Vs 19:12:49 Temperature Measurement, Probe Number = 0, T = 20.258000 C 19:12:49 Temperature Measurement, Probe Number = 1, T = 20.110000 C 19:12:50 Temperature Measurement, Probe Number = 2, T = 20.081000 C 19:12:51 Temperature Measurement, Probe Number = 3, T = 20.041000 C 19:12:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:12:51 Integrated Voltage Measurement... 19:13:10 Voltage Offset Correction: v_off_ini = 0.000001662 V, v_off_fin = 0.000006325 V 19:13:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435362 Vs 19:13:10 Integrated Voltage Measurement... 19:13:30 Voltage Offset Correction: v_off_ini = 0.000005636 V, v_off_fin = -0.000000583 V 19:13:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299710 Vs 19:13:33 Temperature Measurement, Probe Number = 0, T = 20.281000 C 19:13:33 Temperature Measurement, Probe Number = 1, T = 20.111000 C 19:13:34 Temperature Measurement, Probe Number = 2, T = 20.080000 C 19:13:34 Temperature Measurement, Probe Number = 3, T = 20.042000 C 19:13:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:13:35 Integrated Voltage Measurement... 19:13:54 Voltage Offset Correction: v_off_ini = 0.000002409 V, v_off_fin = 0.000006552 V 19:13:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437211 Vs 19:13:54 Integrated Voltage Measurement... 19:14:13 Voltage Offset Correction: v_off_ini = 0.000005792 V, v_off_fin = -0.000001307 V 19:14:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294669 Vs 19:14:16 Temperature Measurement, Probe Number = 0, T = 20.313000 C 19:14:17 Temperature Measurement, Probe Number = 1, T = 20.108000 C 19:14:18 Temperature Measurement, Probe Number = 2, T = 20.082000 C 19:14:18 Temperature Measurement, Probe Number = 3, T = 20.039000 C 19:14:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:14:18 Integrated Voltage Measurement... 19:14:38 Voltage Offset Correction: v_off_ini = 0.000002106 V, v_off_fin = 0.000006863 V 19:14:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441138 Vs 19:14:38 Integrated Voltage Measurement... 19:14:57 Voltage Offset Correction: v_off_ini = 0.000005708 V, v_off_fin = -0.000001764 V 19:14:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292702 Vs 19:15:00 Temperature Measurement, Probe Number = 0, T = 20.315000 C 19:15:01 Temperature Measurement, Probe Number = 1, T = 20.107000 C 19:15:01 Temperature Measurement, Probe Number = 2, T = 20.086000 C 19:15:02 Temperature Measurement, Probe Number = 3, T = 20.045000 C 19:15:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.05 19:15:02 Integrated Voltage Measurement... 19:15:21 Voltage Offset Correction: v_off_ini = 0.000002154 V, v_off_fin = 0.000005947 V 19:15:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434774 Vs 19:15:22 Integrated Voltage Measurement... 19:15:41 Voltage Offset Correction: v_off_ini = 0.000005867 V, v_off_fin = -0.000002283 V 19:15:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305573 Vs 19:15:44 Temperature Measurement, Probe Number = 0, T = 20.339000 C 19:15:44 Temperature Measurement, Probe Number = 1, T = 20.108000 C 19:15:45 Temperature Measurement, Probe Number = 2, T = 20.082000 C 19:15:45 Temperature Measurement, Probe Number = 3, T = 20.045000 C 19:15:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 19:15:46 Integrated Voltage Measurement... 19:16:05 Voltage Offset Correction: v_off_ini = 0.000001716 V, v_off_fin = 0.000005698 V 19:16:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425816 Vs 19:16:05 Integrated Voltage Measurement... 19:16:24 Voltage Offset Correction: v_off_ini = 0.000004978 V, v_off_fin = -0.000001882 V 19:16:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306465 Vs 19:16:27 Temperature Measurement, Probe Number = 0, T = 20.299000 C 19:16:28 Temperature Measurement, Probe Number = 1, T = 20.108000 C 19:16:28 Temperature Measurement, Probe Number = 2, T = 20.081000 C 19:16:29 Temperature Measurement, Probe Number = 3, T = 20.043000 C 19:16:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:16:29 Integrated Voltage Measurement... 19:16:48 Voltage Offset Correction: v_off_ini = 0.000001345 V, v_off_fin = 0.000005964 V 19:16:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432356 Vs 19:16:49 Integrated Voltage Measurement... 19:17:08 Voltage Offset Correction: v_off_ini = 0.000005011 V, v_off_fin = -0.000001027 V 19:17:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308046 Vs 19:17:11 Temperature Measurement, Probe Number = 0, T = 20.275000 C 19:17:11 Temperature Measurement, Probe Number = 1, T = 20.108000 C 19:17:12 Temperature Measurement, Probe Number = 2, T = 20.076000 C 19:17:12 Temperature Measurement, Probe Number = 3, T = 20.039000 C 19:17:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:17:13 Integrated Voltage Measurement... 19:17:32 Voltage Offset Correction: v_off_ini = 0.000001699 V, v_off_fin = 0.000006458 V 19:17:32 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435515 Vs 19:17:32 Integrated Voltage Measurement... 19:17:51 Voltage Offset Correction: v_off_ini = 0.000005304 V, v_off_fin = -0.000001462 V 19:17:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306579 Vs 19:17:54 Temperature Measurement, Probe Number = 0, T = 20.233000 C 19:17:55 Temperature Measurement, Probe Number = 1, T = 20.102000 C 19:17:55 Temperature Measurement, Probe Number = 2, T = 20.067000 C 19:17:56 Temperature Measurement, Probe Number = 3, T = 20.035000 C 19:17:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:17:56 Integrated Voltage Measurement... 19:18:15 Voltage Offset Correction: v_off_ini = 0.000001884 V, v_off_fin = 0.000006921 V 19:18:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445523 Vs 19:18:16 Integrated Voltage Measurement... 19:18:35 Voltage Offset Correction: v_off_ini = 0.000005936 V, v_off_fin = -0.000001387 V 19:18:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305688 Vs 19:48:38 Temperature Measurement, Probe Number = 0, T = 20.101000 C 19:48:39 Temperature Measurement, Probe Number = 1, T = 20.093000 C 19:48:40 Temperature Measurement, Probe Number = 2, T = 20.063000 C 19:48:40 Temperature Measurement, Probe Number = 3, T = 20.029000 C 19:48:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 19:48:40 Integrated Voltage Measurement... 19:49:00 Voltage Offset Correction: v_off_ini = 0.000004642 V, v_off_fin = 0.000006023 V 19:49:00 Integrated Voltage Measurement Delta Gap = 0.0040027 m VT = 0.175521292 Vs 19:49:00 Integrated Voltage Measurement... 19:49:19 Voltage Offset Correction: v_off_ini = 0.000005096 V, v_off_fin = -0.000001307 V 19:49:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306916 Vs 19:49:22 Temperature Measurement, Probe Number = 0, T = 20.058000 C 19:49:23 Temperature Measurement, Probe Number = 1, T = 20.095000 C 19:49:23 Temperature Measurement, Probe Number = 2, T = 20.067000 C 19:49:24 Temperature Measurement, Probe Number = 3, T = 20.031000 C 19:49:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:49:24 Integrated Voltage Measurement... 19:49:43 Voltage Offset Correction: v_off_ini = 0.000002034 V, v_off_fin = 0.000006634 V 19:49:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438572 Vs 19:49:43 Integrated Voltage Measurement... 19:50:02 Voltage Offset Correction: v_off_ini = 0.000006182 V, v_off_fin = -0.000001475 V 19:50:02 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309108 Vs 19:50:05 Temperature Measurement, Probe Number = 0, T = 20.112000 C 19:50:06 Temperature Measurement, Probe Number = 1, T = 20.097000 C 19:50:06 Temperature Measurement, Probe Number = 2, T = 20.064000 C 19:50:07 Temperature Measurement, Probe Number = 3, T = 20.033000 C 19:50:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 19:50:07 Integrated Voltage Measurement... 19:50:26 Voltage Offset Correction: v_off_ini = 0.000001885 V, v_off_fin = 0.000006290 V 19:50:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175442160 Vs 19:50:27 Integrated Voltage Measurement... 19:50:46 Voltage Offset Correction: v_off_ini = 0.000005408 V, v_off_fin = -0.000001489 V 19:50:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313557 Vs 19:50:49 Temperature Measurement, Probe Number = 0, T = 20.157000 C 19:50:50 Temperature Measurement, Probe Number = 1, T = 20.093000 C 19:50:50 Temperature Measurement, Probe Number = 2, T = 20.062000 C 19:50:51 Temperature Measurement, Probe Number = 3, T = 20.027000 C 19:50:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 19:50:51 Integrated Voltage Measurement... 19:51:10 Voltage Offset Correction: v_off_ini = 0.000001118 V, v_off_fin = 0.000006584 V 19:51:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439094 Vs 19:51:10 Integrated Voltage Measurement... 19:51:29 Voltage Offset Correction: v_off_ini = 0.000005344 V, v_off_fin = -0.000001719 V 19:51:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305173 Vs 19:51:32 Temperature Measurement, Probe Number = 0, T = 20.124000 C 19:51:33 Temperature Measurement, Probe Number = 1, T = 20.093000 C 19:51:34 Temperature Measurement, Probe Number = 2, T = 20.065000 C 19:51:34 Temperature Measurement, Probe Number = 3, T = 20.026000 C 19:51:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:51:34 Integrated Voltage Measurement... 19:51:54 Voltage Offset Correction: v_off_ini = 0.000001404 V, v_off_fin = 0.000005798 V 19:51:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439014 Vs 19:51:54 Integrated Voltage Measurement... 19:52:13 Voltage Offset Correction: v_off_ini = 0.000005103 V, v_off_fin = -0.000001276 V 19:52:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315481 Vs 19:52:16 Temperature Measurement, Probe Number = 0, T = 20.041000 C 19:52:17 Temperature Measurement, Probe Number = 1, T = 20.096000 C 19:52:17 Temperature Measurement, Probe Number = 2, T = 20.068000 C 19:52:18 Temperature Measurement, Probe Number = 3, T = 20.031000 C 19:52:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:52:18 Integrated Voltage Measurement... 19:52:37 Voltage Offset Correction: v_off_ini = 0.000002030 V, v_off_fin = 0.000006170 V 19:52:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440765 Vs 19:52:38 Integrated Voltage Measurement... 19:52:57 Voltage Offset Correction: v_off_ini = 0.000005242 V, v_off_fin = -0.000002609 V 19:52:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306989 Vs 19:53:00 Temperature Measurement, Probe Number = 0, T = 20.007000 C 19:53:00 Temperature Measurement, Probe Number = 1, T = 20.094000 C 19:53:01 Temperature Measurement, Probe Number = 2, T = 20.067000 C 19:53:02 Temperature Measurement, Probe Number = 3, T = 20.027000 C 19:53:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.01 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:53:02 Integrated Voltage Measurement... 19:53:21 Voltage Offset Correction: v_off_ini = 0.000000792 V, v_off_fin = 0.000005899 V 19:53:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438506 Vs 19:53:21 Integrated Voltage Measurement... 19:53:40 Voltage Offset Correction: v_off_ini = 0.000005508 V, v_off_fin = -0.000001491 V 19:53:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304060 Vs 19:53:43 Temperature Measurement, Probe Number = 0, T = 20.061000 C 19:53:44 Temperature Measurement, Probe Number = 1, T = 20.094000 C 19:53:45 Temperature Measurement, Probe Number = 2, T = 20.064000 C 19:53:45 Temperature Measurement, Probe Number = 3, T = 20.028000 C 19:53:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 19:53:45 Integrated Voltage Measurement... 19:54:05 Voltage Offset Correction: v_off_ini = 0.000001178 V, v_off_fin = 0.000006125 V 19:54:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439042 Vs 19:54:05 Integrated Voltage Measurement... 19:54:24 Voltage Offset Correction: v_off_ini = 0.000005815 V, v_off_fin = -0.000001933 V 19:54:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310060 Vs 19:54:27 Temperature Measurement, Probe Number = 0, T = 20.130000 C 19:54:27 Temperature Measurement, Probe Number = 1, T = 20.095000 C 19:54:28 Temperature Measurement, Probe Number = 2, T = 20.068000 C 19:54:29 Temperature Measurement, Probe Number = 3, T = 20.033000 C 19:54:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:54:29 Integrated Voltage Measurement... 19:54:49 Voltage Offset Correction: v_off_ini = 0.000001957 V, v_off_fin = 0.000006957 V 19:54:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450389 Vs 19:54:49 Integrated Voltage Measurement... 19:55:08 Voltage Offset Correction: v_off_ini = 0.000006007 V, v_off_fin = -0.000001834 V 19:55:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301900 Vs 19:55:11 Temperature Measurement, Probe Number = 0, T = 20.133000 C 19:55:11 Temperature Measurement, Probe Number = 1, T = 20.093000 C 19:55:12 Temperature Measurement, Probe Number = 2, T = 20.070000 C 19:55:12 Temperature Measurement, Probe Number = 3, T = 20.031000 C 19:55:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 19:55:13 Integrated Voltage Measurement... 19:55:32 Voltage Offset Correction: v_off_ini = 0.000001645 V, v_off_fin = 0.000005749 V 19:55:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440276 Vs 19:55:32 Integrated Voltage Measurement... 19:55:51 Voltage Offset Correction: v_off_ini = 0.000005247 V, v_off_fin = -0.000003040 V 19:55:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315061 Vs 20:25:54 Temperature Measurement, Probe Number = 0, T = 19.982000 C 20:25:54 Temperature Measurement, Probe Number = 1, T = 20.078000 C 20:25:55 Temperature Measurement, Probe Number = 2, T = 20.046000 C 20:25:56 Temperature Measurement, Probe Number = 3, T = 20.014000 C 20:25:56 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 20:25:56 Integrated Voltage Measurement... 20:26:15 Voltage Offset Correction: v_off_ini = 0.000004031 V, v_off_fin = 0.000006542 V 20:26:15 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175528210 Vs 20:26:15 Integrated Voltage Measurement... 20:26:34 Voltage Offset Correction: v_off_ini = 0.000005856 V, v_off_fin = -0.000001054 V 20:26:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175302597 Vs 20:26:37 Temperature Measurement, Probe Number = 0, T = 20.008000 C 20:26:38 Temperature Measurement, Probe Number = 1, T = 20.084000 C 20:26:39 Temperature Measurement, Probe Number = 2, T = 20.053000 C 20:26:39 Temperature Measurement, Probe Number = 3, T = 20.018000 C 20:26:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.01 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:26:39 Integrated Voltage Measurement... 20:26:58 Voltage Offset Correction: v_off_ini = 0.000002350 V, v_off_fin = 0.000006336 V 20:26:59 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175431140 Vs 20:26:59 Integrated Voltage Measurement... 20:27:18 Voltage Offset Correction: v_off_ini = 0.000005632 V, v_off_fin = -0.000001884 V 20:27:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306639 Vs 20:27:21 Temperature Measurement, Probe Number = 0, T = 20.039000 C 20:27:21 Temperature Measurement, Probe Number = 1, T = 20.085000 C 20:27:22 Temperature Measurement, Probe Number = 2, T = 20.054000 C 20:27:23 Temperature Measurement, Probe Number = 3, T = 20.018000 C 20:27:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:27:23 Integrated Voltage Measurement... 20:27:42 Voltage Offset Correction: v_off_ini = 0.000002122 V, v_off_fin = 0.000005890 V 20:27:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439377 Vs 20:27:42 Integrated Voltage Measurement... 20:28:01 Voltage Offset Correction: v_off_ini = 0.000005150 V, v_off_fin = -0.000003320 V 20:28:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312205 Vs 20:28:04 Temperature Measurement, Probe Number = 0, T = 20.002000 C 20:28:04 Temperature Measurement, Probe Number = 1, T = 20.083000 C 20:28:05 Temperature Measurement, Probe Number = 2, T = 20.052000 C 20:28:06 Temperature Measurement, Probe Number = 3, T = 20.014000 C 20:28:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 20:28:06 Integrated Voltage Measurement... 20:28:25 Voltage Offset Correction: v_off_ini = 0.000001355 V, v_off_fin = 0.000006284 V 20:28:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440380 Vs 20:28:25 Integrated Voltage Measurement... 20:28:44 Voltage Offset Correction: v_off_ini = 0.000005182 V, v_off_fin = -0.000002055 V 20:28:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311124 Vs 20:28:47 Temperature Measurement, Probe Number = 0, T = 19.987000 C 20:28:48 Temperature Measurement, Probe Number = 1, T = 20.084000 C 20:28:48 Temperature Measurement, Probe Number = 2, T = 20.051000 C 20:28:49 Temperature Measurement, Probe Number = 3, T = 20.016000 C 20:28:49 Magnet Test Parameter Measurements P0 = Room, Value = 19.99 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:28:49 Integrated Voltage Measurement... 20:29:09 Voltage Offset Correction: v_off_ini = 0.000001329 V, v_off_fin = 0.000006471 V 20:29:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441247 Vs 20:29:09 Integrated Voltage Measurement... 20:29:29 Voltage Offset Correction: v_off_ini = 0.000005436 V, v_off_fin = -0.000001442 V 20:29:29 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309553 Vs 20:29:32 Temperature Measurement, Probe Number = 0, T = 19.998000 C 20:29:32 Temperature Measurement, Probe Number = 1, T = 20.084000 C 20:29:33 Temperature Measurement, Probe Number = 2, T = 20.046000 C 20:29:33 Temperature Measurement, Probe Number = 3, T = 20.015000 C 20:29:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:29:34 Integrated Voltage Measurement... 20:29:53 Voltage Offset Correction: v_off_ini = 0.000001803 V, v_off_fin = 0.000005921 V 20:29:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175431673 Vs 20:29:53 Integrated Voltage Measurement... 20:30:12 Voltage Offset Correction: v_off_ini = 0.000005422 V, v_off_fin = -0.000002292 V 20:30:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308118 Vs 20:30:15 Temperature Measurement, Probe Number = 0, T = 19.950000 C 20:30:16 Temperature Measurement, Probe Number = 1, T = 20.084000 C 20:30:16 Temperature Measurement, Probe Number = 2, T = 20.051000 C 20:30:17 Temperature Measurement, Probe Number = 3, T = 20.017000 C 20:30:17 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:30:17 Integrated Voltage Measurement... 20:30:36 Voltage Offset Correction: v_off_ini = 0.000001427 V, v_off_fin = 0.000006156 V 20:30:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442746 Vs 20:30:36 Integrated Voltage Measurement... 20:30:56 Voltage Offset Correction: v_off_ini = 0.000005317 V, v_off_fin = -0.000002758 V 20:30:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313510 Vs 20:30:59 Temperature Measurement, Probe Number = 0, T = 19.970000 C 20:30:59 Temperature Measurement, Probe Number = 1, T = 20.083000 C 20:31:00 Temperature Measurement, Probe Number = 2, T = 20.052000 C 20:31:01 Temperature Measurement, Probe Number = 3, T = 20.017000 C 20:31:01 Magnet Test Parameter Measurements P0 = Room, Value = 19.97 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:31:01 Integrated Voltage Measurement... 20:31:20 Voltage Offset Correction: v_off_ini = 0.000002044 V, v_off_fin = 0.000006334 V 20:31:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440629 Vs 20:31:20 Integrated Voltage Measurement... 20:31:40 Voltage Offset Correction: v_off_ini = 0.000005394 V, v_off_fin = -0.000002058 V 20:31:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315624 Vs 20:31:42 Temperature Measurement, Probe Number = 0, T = 20.060000 C 20:31:43 Temperature Measurement, Probe Number = 1, T = 20.083000 C 20:31:44 Temperature Measurement, Probe Number = 2, T = 20.054000 C 20:31:44 Temperature Measurement, Probe Number = 3, T = 20.018000 C 20:31:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:31:45 Integrated Voltage Measurement... 20:32:04 Voltage Offset Correction: v_off_ini = 0.000001564 V, v_off_fin = 0.000006440 V 20:32:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443307 Vs 20:32:04 Integrated Voltage Measurement... 20:32:24 Voltage Offset Correction: v_off_ini = 0.000005442 V, v_off_fin = -0.000001267 V 20:32:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175308677 Vs 20:32:27 Temperature Measurement, Probe Number = 0, T = 20.057000 C 20:32:27 Temperature Measurement, Probe Number = 1, T = 20.082000 C 20:32:28 Temperature Measurement, Probe Number = 2, T = 20.051000 C 20:32:28 Temperature Measurement, Probe Number = 3, T = 20.019000 C 20:32:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 20:32:29 Integrated Voltage Measurement... 20:32:48 Voltage Offset Correction: v_off_ini = 0.000001508 V, v_off_fin = 0.000006711 V 20:32:48 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175433025 Vs 20:32:48 Integrated Voltage Measurement... 20:33:07 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001305 V 20:33:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308850 Vs 21:03:10 Temperature Measurement, Probe Number = 0, T = 20.118000 C 21:03:11 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:03:11 Temperature Measurement, Probe Number = 2, T = 20.037000 C 21:03:12 Temperature Measurement, Probe Number = 3, T = 20.007000 C 21:03:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 21:03:12 Integrated Voltage Measurement... 21:03:32 Voltage Offset Correction: v_off_ini = 0.000003726 V, v_off_fin = 0.000006699 V 21:03:32 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175525486 Vs 21:03:32 Integrated Voltage Measurement... 21:03:51 Voltage Offset Correction: v_off_ini = 0.000005804 V, v_off_fin = -0.000001500 V 21:03:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309319 Vs 21:03:54 Temperature Measurement, Probe Number = 0, T = 20.118000 C 21:03:55 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:03:55 Temperature Measurement, Probe Number = 2, T = 20.040000 C 21:03:56 Temperature Measurement, Probe Number = 3, T = 20.009000 C 21:03:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 21:03:56 Integrated Voltage Measurement... 21:04:15 Voltage Offset Correction: v_off_ini = 0.000001864 V, v_off_fin = 0.000006329 V 21:04:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437756 Vs 21:04:15 Integrated Voltage Measurement... 21:04:34 Voltage Offset Correction: v_off_ini = 0.000005724 V, v_off_fin = -0.000002257 V 21:04:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312435 Vs 21:04:37 Temperature Measurement, Probe Number = 0, T = 20.126000 C 21:04:38 Temperature Measurement, Probe Number = 1, T = 20.076000 C 21:04:38 Temperature Measurement, Probe Number = 2, T = 20.047000 C 21:04:39 Temperature Measurement, Probe Number = 3, T = 20.019000 C 21:04:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:04:39 Integrated Voltage Measurement... 21:04:58 Voltage Offset Correction: v_off_ini = 0.000001288 V, v_off_fin = 0.000006365 V 21:04:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444904 Vs 21:04:59 Integrated Voltage Measurement... 21:05:18 Voltage Offset Correction: v_off_ini = 0.000005531 V, v_off_fin = -0.000001282 V 21:05:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318762 Vs 21:05:21 Temperature Measurement, Probe Number = 0, T = 20.168000 C 21:05:21 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:05:22 Temperature Measurement, Probe Number = 2, T = 20.047000 C 21:05:23 Temperature Measurement, Probe Number = 3, T = 20.013000 C 21:05:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:05:23 Integrated Voltage Measurement... 21:05:42 Voltage Offset Correction: v_off_ini = 0.000002335 V, v_off_fin = 0.000006799 V 21:05:42 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175448768 Vs 21:05:42 Integrated Voltage Measurement... 21:06:01 Voltage Offset Correction: v_off_ini = 0.000006002 V, v_off_fin = -0.000001589 V 21:06:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313036 Vs 21:06:04 Temperature Measurement, Probe Number = 0, T = 20.195000 C 21:06:05 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:06:05 Temperature Measurement, Probe Number = 2, T = 20.049000 C 21:06:06 Temperature Measurement, Probe Number = 3, T = 20.015000 C 21:06:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:06:06 Integrated Voltage Measurement... 21:06:25 Voltage Offset Correction: v_off_ini = 0.000002604 V, v_off_fin = 0.000006562 V 21:06:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175449576 Vs 21:06:26 Integrated Voltage Measurement... 21:06:45 Voltage Offset Correction: v_off_ini = 0.000005996 V, v_off_fin = -0.000001566 V 21:06:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316125 Vs 21:06:48 Temperature Measurement, Probe Number = 0, T = 20.224000 C 21:06:49 Temperature Measurement, Probe Number = 1, T = 20.077000 C 21:06:49 Temperature Measurement, Probe Number = 2, T = 20.046000 C 21:06:50 Temperature Measurement, Probe Number = 3, T = 20.016000 C 21:06:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:06:50 Integrated Voltage Measurement... 21:07:09 Voltage Offset Correction: v_off_ini = 0.000002269 V, v_off_fin = 0.000006306 V 21:07:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445133 Vs 21:07:10 Integrated Voltage Measurement... 21:07:29 Voltage Offset Correction: v_off_ini = 0.000005548 V, v_off_fin = -0.000001986 V 21:07:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322323 Vs 21:07:32 Temperature Measurement, Probe Number = 0, T = 20.208000 C 21:07:33 Temperature Measurement, Probe Number = 1, T = 20.077000 C 21:07:33 Temperature Measurement, Probe Number = 2, T = 20.046000 C 21:07:34 Temperature Measurement, Probe Number = 3, T = 20.013000 C 21:07:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:07:34 Integrated Voltage Measurement... 21:07:53 Voltage Offset Correction: v_off_ini = 0.000001664 V, v_off_fin = 0.000006625 V 21:07:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444127 Vs 21:07:53 Integrated Voltage Measurement... 21:08:13 Voltage Offset Correction: v_off_ini = 0.000005514 V, v_off_fin = -0.000001289 V 21:08:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315576 Vs 21:08:15 Temperature Measurement, Probe Number = 0, T = 20.198000 C 21:08:16 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:08:17 Temperature Measurement, Probe Number = 2, T = 20.040000 C 21:08:17 Temperature Measurement, Probe Number = 3, T = 20.012000 C 21:08:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 21:08:17 Integrated Voltage Measurement... 21:08:37 Voltage Offset Correction: v_off_ini = 0.000001733 V, v_off_fin = 0.000006093 V 21:08:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444672 Vs 21:08:37 Integrated Voltage Measurement... 21:08:56 Voltage Offset Correction: v_off_ini = 0.000005150 V, v_off_fin = -0.000001260 V 21:08:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321901 Vs 21:08:59 Temperature Measurement, Probe Number = 0, T = 20.196000 C 21:09:00 Temperature Measurement, Probe Number = 1, T = 20.074000 C 21:09:00 Temperature Measurement, Probe Number = 2, T = 20.046000 C 21:09:01 Temperature Measurement, Probe Number = 3, T = 20.010000 C 21:09:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:09:01 Integrated Voltage Measurement... 21:09:21 Voltage Offset Correction: v_off_ini = 0.000002031 V, v_off_fin = 0.000006204 V 21:09:21 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453634 Vs 21:09:21 Integrated Voltage Measurement... 21:09:40 Voltage Offset Correction: v_off_ini = 0.000005627 V, v_off_fin = -0.000001704 V 21:09:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175330869 Vs 21:09:43 Temperature Measurement, Probe Number = 0, T = 20.246000 C 21:09:44 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:09:44 Temperature Measurement, Probe Number = 2, T = 20.045000 C 21:09:45 Temperature Measurement, Probe Number = 3, T = 20.009000 C 21:09:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:09:45 Integrated Voltage Measurement... 21:10:05 Voltage Offset Correction: v_off_ini = 0.000001624 V, v_off_fin = 0.000006214 V 21:10:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175449092 Vs 21:10:05 Integrated Voltage Measurement... 21:10:24 Voltage Offset Correction: v_off_ini = 0.000005710 V, v_off_fin = -0.000001397 V 21:10:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175318670 Vs 21:40:27 Temperature Measurement, Probe Number = 0, T = 20.201000 C 21:40:28 Temperature Measurement, Probe Number = 1, T = 20.067000 C 21:40:29 Temperature Measurement, Probe Number = 2, T = 20.037000 C 21:40:29 Temperature Measurement, Probe Number = 3, T = 20.006000 C 21:40:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 21:40:29 Integrated Voltage Measurement... 21:40:48 Voltage Offset Correction: v_off_ini = 0.000003987 V, v_off_fin = 0.000006335 V 21:40:49 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175535851 Vs 21:40:49 Integrated Voltage Measurement... 21:41:08 Voltage Offset Correction: v_off_ini = 0.000005897 V, v_off_fin = -0.000002115 V 21:41:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309099 Vs 21:41:10 Temperature Measurement, Probe Number = 0, T = 20.165000 C 21:41:11 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:41:12 Temperature Measurement, Probe Number = 2, T = 20.045000 C 21:41:12 Temperature Measurement, Probe Number = 3, T = 20.014000 C 21:41:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:41:13 Integrated Voltage Measurement... 21:41:32 Voltage Offset Correction: v_off_ini = 0.000001905 V, v_off_fin = 0.000006196 V 21:41:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445258 Vs 21:41:32 Integrated Voltage Measurement... 21:41:51 Voltage Offset Correction: v_off_ini = 0.000005677 V, v_off_fin = -0.000001452 V 21:41:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307592 Vs 21:41:54 Temperature Measurement, Probe Number = 0, T = 20.166000 C 21:41:55 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:41:56 Temperature Measurement, Probe Number = 2, T = 20.048000 C 21:41:56 Temperature Measurement, Probe Number = 3, T = 20.018000 C 21:41:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:41:56 Integrated Voltage Measurement... 21:42:15 Voltage Offset Correction: v_off_ini = 0.000002367 V, v_off_fin = 0.000006222 V 21:42:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439969 Vs 21:42:16 Integrated Voltage Measurement... 21:42:36 Voltage Offset Correction: v_off_ini = 0.000005514 V, v_off_fin = -0.000001544 V 21:42:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313030 Vs 21:42:38 Temperature Measurement, Probe Number = 0, T = 20.216000 C 21:42:39 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:42:40 Temperature Measurement, Probe Number = 2, T = 20.049000 C 21:42:40 Temperature Measurement, Probe Number = 3, T = 20.018000 C 21:42:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:42:41 Integrated Voltage Measurement... 21:43:00 Voltage Offset Correction: v_off_ini = 0.000003025 V, v_off_fin = 0.000006073 V 21:43:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175433003 Vs 21:43:00 Integrated Voltage Measurement... 21:43:19 Voltage Offset Correction: v_off_ini = 0.000005548 V, v_off_fin = -0.000002042 V 21:43:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318275 Vs 21:43:22 Temperature Measurement, Probe Number = 0, T = 20.238000 C 21:43:23 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:43:24 Temperature Measurement, Probe Number = 2, T = 20.043000 C 21:43:24 Temperature Measurement, Probe Number = 3, T = 20.016000 C 21:43:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 21:43:24 Integrated Voltage Measurement... 21:43:44 Voltage Offset Correction: v_off_ini = 0.000001858 V, v_off_fin = 0.000006328 V 21:43:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445563 Vs 21:43:44 Integrated Voltage Measurement... 21:44:03 Voltage Offset Correction: v_off_ini = 0.000005861 V, v_off_fin = -0.000001838 V 21:44:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306748 Vs 21:44:06 Temperature Measurement, Probe Number = 0, T = 20.280000 C 21:44:07 Temperature Measurement, Probe Number = 1, T = 20.074000 C 21:44:07 Temperature Measurement, Probe Number = 2, T = 20.041000 C 21:44:08 Temperature Measurement, Probe Number = 3, T = 20.014000 C 21:44:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 21:44:08 Integrated Voltage Measurement... 21:44:27 Voltage Offset Correction: v_off_ini = 0.000001865 V, v_off_fin = 0.000006207 V 21:44:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448672 Vs 21:44:28 Integrated Voltage Measurement... 21:44:47 Voltage Offset Correction: v_off_ini = 0.000005218 V, v_off_fin = -0.000001299 V 21:44:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309670 Vs 21:44:50 Temperature Measurement, Probe Number = 0, T = 20.286000 C 21:44:50 Temperature Measurement, Probe Number = 1, T = 20.074000 C 21:44:51 Temperature Measurement, Probe Number = 2, T = 20.046000 C 21:44:52 Temperature Measurement, Probe Number = 3, T = 20.012000 C 21:44:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:44:52 Integrated Voltage Measurement... 21:45:11 Voltage Offset Correction: v_off_ini = 0.000001826 V, v_off_fin = 0.000006209 V 21:45:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445399 Vs 21:45:11 Integrated Voltage Measurement... 21:45:31 Voltage Offset Correction: v_off_ini = 0.000006079 V, v_off_fin = -0.000001236 V 21:45:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319835 Vs 21:45:33 Temperature Measurement, Probe Number = 0, T = 20.258000 C 21:45:34 Temperature Measurement, Probe Number = 1, T = 20.072000 C 21:45:35 Temperature Measurement, Probe Number = 2, T = 20.048000 C 21:45:35 Temperature Measurement, Probe Number = 3, T = 20.012000 C 21:45:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:45:36 Integrated Voltage Measurement... 21:45:55 Voltage Offset Correction: v_off_ini = 0.000002650 V, v_off_fin = 0.000006365 V 21:45:55 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439472 Vs 21:45:55 Integrated Voltage Measurement... 21:46:14 Voltage Offset Correction: v_off_ini = 0.000005283 V, v_off_fin = -0.000002440 V 21:46:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318874 Vs 21:46:17 Temperature Measurement, Probe Number = 0, T = 20.261000 C 21:46:18 Temperature Measurement, Probe Number = 1, T = 20.073000 C 21:46:18 Temperature Measurement, Probe Number = 2, T = 20.045000 C 21:46:19 Temperature Measurement, Probe Number = 3, T = 20.013000 C 21:46:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 21:46:19 Integrated Voltage Measurement... 21:46:38 Voltage Offset Correction: v_off_ini = 0.000002172 V, v_off_fin = 0.000006686 V 21:46:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450206 Vs 21:46:38 Integrated Voltage Measurement... 21:46:58 Voltage Offset Correction: v_off_ini = 0.000005627 V, v_off_fin = -0.000001579 V 21:46:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175327343 Vs 21:47:01 Temperature Measurement, Probe Number = 0, T = 20.239000 C 21:47:01 Temperature Measurement, Probe Number = 1, T = 20.074000 C 21:47:02 Temperature Measurement, Probe Number = 2, T = 20.048000 C 21:47:02 Temperature Measurement, Probe Number = 3, T = 20.016000 C 21:47:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:47:03 Integrated Voltage Measurement... 21:47:22 Voltage Offset Correction: v_off_ini = 0.000002055 V, v_off_fin = 0.000006287 V 21:47:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445072 Vs 21:47:22 Integrated Voltage Measurement... 21:47:42 Voltage Offset Correction: v_off_ini = 0.000005611 V, v_off_fin = -0.000002096 V 21:47:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175321737 Vs 22:17:45 Temperature Measurement, Probe Number = 0, T = 20.315000 C 22:17:45 Temperature Measurement, Probe Number = 1, T = 20.072000 C 22:17:46 Temperature Measurement, Probe Number = 2, T = 20.044000 C 22:17:47 Temperature Measurement, Probe Number = 3, T = 20.011000 C 22:17:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:17:47 Integrated Voltage Measurement... 22:18:06 Voltage Offset Correction: v_off_ini = 0.000004182 V, v_off_fin = 0.000006118 V 22:18:06 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175542086 Vs 22:18:06 Integrated Voltage Measurement... 22:18:26 Voltage Offset Correction: v_off_ini = 0.000005854 V, v_off_fin = -0.000001932 V 22:18:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311950 Vs 22:18:28 Temperature Measurement, Probe Number = 0, T = 20.296000 C 22:18:29 Temperature Measurement, Probe Number = 1, T = 20.073000 C 22:18:30 Temperature Measurement, Probe Number = 2, T = 20.043000 C 22:18:30 Temperature Measurement, Probe Number = 3, T = 20.012000 C 22:18:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:18:31 Integrated Voltage Measurement... 22:18:50 Voltage Offset Correction: v_off_ini = 0.000002433 V, v_off_fin = 0.000006421 V 22:18:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175441050 Vs 22:18:50 Integrated Voltage Measurement... 22:19:09 Voltage Offset Correction: v_off_ini = 0.000005659 V, v_off_fin = -0.000002067 V 22:19:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307171 Vs 22:19:12 Temperature Measurement, Probe Number = 0, T = 20.306000 C 22:19:13 Temperature Measurement, Probe Number = 1, T = 20.074000 C 22:19:13 Temperature Measurement, Probe Number = 2, T = 20.042000 C 22:19:14 Temperature Measurement, Probe Number = 3, T = 20.012000 C 22:19:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:19:14 Integrated Voltage Measurement... 22:19:34 Voltage Offset Correction: v_off_ini = 0.000002066 V, v_off_fin = 0.000006530 V 22:19:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446223 Vs 22:19:34 Integrated Voltage Measurement... 22:19:53 Voltage Offset Correction: v_off_ini = 0.000005651 V, v_off_fin = -0.000002038 V 22:19:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310544 Vs 22:19:56 Temperature Measurement, Probe Number = 0, T = 20.304000 C 22:19:57 Temperature Measurement, Probe Number = 1, T = 20.070000 C 22:19:57 Temperature Measurement, Probe Number = 2, T = 20.037000 C 22:19:58 Temperature Measurement, Probe Number = 3, T = 20.010000 C 22:19:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:19:58 Integrated Voltage Measurement... 22:20:17 Voltage Offset Correction: v_off_ini = 0.000001438 V, v_off_fin = 0.000006487 V 22:20:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443594 Vs 22:20:17 Integrated Voltage Measurement... 22:20:37 Voltage Offset Correction: v_off_ini = 0.000005955 V, v_off_fin = -0.000001470 V 22:20:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313815 Vs 22:20:40 Temperature Measurement, Probe Number = 0, T = 20.249000 C 22:20:40 Temperature Measurement, Probe Number = 1, T = 20.069000 C 22:20:41 Temperature Measurement, Probe Number = 2, T = 20.036000 C 22:20:42 Temperature Measurement, Probe Number = 3, T = 20.006000 C 22:20:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:20:42 Integrated Voltage Measurement... 22:21:01 Voltage Offset Correction: v_off_ini = 0.000001934 V, v_off_fin = 0.000005988 V 22:21:01 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444578 Vs 22:21:01 Integrated Voltage Measurement... 22:21:20 Voltage Offset Correction: v_off_ini = 0.000005668 V, v_off_fin = -0.000001298 V 22:21:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306151 Vs 22:21:23 Temperature Measurement, Probe Number = 0, T = 20.186000 C 22:21:24 Temperature Measurement, Probe Number = 1, T = 20.070000 C 22:21:25 Temperature Measurement, Probe Number = 2, T = 20.043000 C 22:21:25 Temperature Measurement, Probe Number = 3, T = 20.008000 C 22:21:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:21:25 Integrated Voltage Measurement... 22:21:44 Voltage Offset Correction: v_off_ini = 0.000001784 V, v_off_fin = 0.000006408 V 22:21:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444308 Vs 22:21:45 Integrated Voltage Measurement... 22:22:04 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001816 V 22:22:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315177 Vs 22:22:07 Temperature Measurement, Probe Number = 0, T = 20.166000 C 22:22:07 Temperature Measurement, Probe Number = 1, T = 20.072000 C 22:22:08 Temperature Measurement, Probe Number = 2, T = 20.043000 C 22:22:09 Temperature Measurement, Probe Number = 3, T = 20.008000 C 22:22:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:22:09 Integrated Voltage Measurement... 22:22:28 Voltage Offset Correction: v_off_ini = 0.000002118 V, v_off_fin = 0.000005888 V 22:22:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438328 Vs 22:22:28 Integrated Voltage Measurement... 22:22:47 Voltage Offset Correction: v_off_ini = 0.000005232 V, v_off_fin = -0.000002340 V 22:22:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313788 Vs 22:22:50 Temperature Measurement, Probe Number = 0, T = 20.230000 C 22:22:51 Temperature Measurement, Probe Number = 1, T = 20.074000 C 22:22:52 Temperature Measurement, Probe Number = 2, T = 20.044000 C 22:22:52 Temperature Measurement, Probe Number = 3, T = 20.015000 C 22:22:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:22:52 Integrated Voltage Measurement... 22:23:11 Voltage Offset Correction: v_off_ini = 0.000001526 V, v_off_fin = 0.000005914 V 22:23:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443506 Vs 22:23:12 Integrated Voltage Measurement... 22:23:31 Voltage Offset Correction: v_off_ini = 0.000005359 V, v_off_fin = -0.000001956 V 22:23:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318898 Vs 22:23:34 Temperature Measurement, Probe Number = 0, T = 20.212000 C 22:23:35 Temperature Measurement, Probe Number = 1, T = 20.070000 C 22:23:35 Temperature Measurement, Probe Number = 2, T = 20.041000 C 22:23:36 Temperature Measurement, Probe Number = 3, T = 20.013000 C 22:23:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:23:36 Integrated Voltage Measurement... 22:23:55 Voltage Offset Correction: v_off_ini = 0.000002234 V, v_off_fin = 0.000006405 V 22:23:55 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444237 Vs 22:23:55 Integrated Voltage Measurement... 22:24:15 Voltage Offset Correction: v_off_ini = 0.000006043 V, v_off_fin = -0.000001199 V 22:24:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309598 Vs 22:24:17 Temperature Measurement, Probe Number = 0, T = 20.189000 C 22:24:18 Temperature Measurement, Probe Number = 1, T = 20.072000 C 22:24:19 Temperature Measurement, Probe Number = 2, T = 20.045000 C 22:24:19 Temperature Measurement, Probe Number = 3, T = 20.013000 C 22:24:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.01 22:24:19 Integrated Voltage Measurement... 22:24:39 Voltage Offset Correction: v_off_ini = 0.000002106 V, v_off_fin = 0.000006511 V 22:24:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450596 Vs 22:24:39 Integrated Voltage Measurement... 22:24:58 Voltage Offset Correction: v_off_ini = 0.000006579 V, v_off_fin = -0.000001802 V 22:24:58 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175317417 Vs 22:55:01 Temperature Measurement, Probe Number = 0, T = 20.238000 C 22:55:02 Temperature Measurement, Probe Number = 1, T = 20.065000 C 22:55:02 Temperature Measurement, Probe Number = 2, T = 20.036000 C 22:55:03 Temperature Measurement, Probe Number = 3, T = 20.005000 C 22:55:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 22:55:03 Integrated Voltage Measurement... 22:55:22 Voltage Offset Correction: v_off_ini = 0.000003519 V, v_off_fin = 0.000006220 V 22:55:22 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175519349 Vs 22:55:23 Integrated Voltage Measurement... 22:55:42 Voltage Offset Correction: v_off_ini = 0.000005500 V, v_off_fin = -0.000002038 V 22:55:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321503 Vs 22:55:45 Temperature Measurement, Probe Number = 0, T = 20.244000 C 22:55:45 Temperature Measurement, Probe Number = 1, T = 20.070000 C 22:55:46 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:55:47 Temperature Measurement, Probe Number = 3, T = 20.010000 C 22:55:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:55:47 Integrated Voltage Measurement... 22:56:06 Voltage Offset Correction: v_off_ini = 0.000001551 V, v_off_fin = 0.000006469 V 22:56:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175445136 Vs 22:56:07 Integrated Voltage Measurement... 22:56:25 Voltage Offset Correction: v_off_ini = 0.000005738 V, v_off_fin = -0.000000857 V 22:56:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311211 Vs 22:56:28 Temperature Measurement, Probe Number = 0, T = 20.290000 C 22:56:29 Temperature Measurement, Probe Number = 1, T = 20.071000 C 22:56:30 Temperature Measurement, Probe Number = 2, T = 20.044000 C 22:56:30 Temperature Measurement, Probe Number = 3, T = 20.009000 C 22:56:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:56:30 Integrated Voltage Measurement... 22:56:50 Voltage Offset Correction: v_off_ini = 0.000002004 V, v_off_fin = 0.000006649 V 22:56:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448078 Vs 22:56:50 Integrated Voltage Measurement... 22:57:09 Voltage Offset Correction: v_off_ini = 0.000005820 V, v_off_fin = -0.000001052 V 22:57:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313184 Vs 22:57:12 Temperature Measurement, Probe Number = 0, T = 20.265000 C 22:57:13 Temperature Measurement, Probe Number = 1, T = 20.069000 C 22:57:13 Temperature Measurement, Probe Number = 2, T = 20.043000 C 22:57:14 Temperature Measurement, Probe Number = 3, T = 20.008000 C 22:57:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:57:14 Integrated Voltage Measurement... 22:57:33 Voltage Offset Correction: v_off_ini = 0.000002533 V, v_off_fin = 0.000006611 V 22:57:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175447815 Vs 22:57:34 Integrated Voltage Measurement... 22:57:53 Voltage Offset Correction: v_off_ini = 0.000005882 V, v_off_fin = -0.000001301 V 22:57:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310678 Vs 22:57:55 Temperature Measurement, Probe Number = 0, T = 20.203000 C 22:57:56 Temperature Measurement, Probe Number = 1, T = 20.073000 C 22:57:57 Temperature Measurement, Probe Number = 2, T = 20.044000 C 22:57:57 Temperature Measurement, Probe Number = 3, T = 20.010000 C 22:57:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:57:57 Integrated Voltage Measurement... 22:58:17 Voltage Offset Correction: v_off_ini = 0.000001591 V, v_off_fin = 0.000005851 V 22:58:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175443006 Vs 22:58:17 Integrated Voltage Measurement... 22:58:36 Voltage Offset Correction: v_off_ini = 0.000005210 V, v_off_fin = -0.000002217 V 22:58:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319098 Vs 22:58:39 Temperature Measurement, Probe Number = 0, T = 20.242000 C 22:58:39 Temperature Measurement, Probe Number = 1, T = 20.069000 C 22:58:40 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:58:40 Temperature Measurement, Probe Number = 3, T = 20.009000 C 22:58:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:58:41 Integrated Voltage Measurement... 22:59:00 Voltage Offset Correction: v_off_ini = 0.000000860 V, v_off_fin = 0.000006246 V 22:59:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447047 Vs 22:59:00 Integrated Voltage Measurement... 22:59:20 Voltage Offset Correction: v_off_ini = 0.000005760 V, v_off_fin = -0.000000650 V 22:59:20 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175325764 Vs 22:59:22 Temperature Measurement, Probe Number = 0, T = 20.235000 C 22:59:23 Temperature Measurement, Probe Number = 1, T = 20.066000 C 22:59:24 Temperature Measurement, Probe Number = 2, T = 20.039000 C 22:59:24 Temperature Measurement, Probe Number = 3, T = 20.004000 C 22:59:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 22:59:25 Integrated Voltage Measurement... 22:59:44 Voltage Offset Correction: v_off_ini = 0.000001791 V, v_off_fin = 0.000006340 V 22:59:44 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175443471 Vs 22:59:44 Integrated Voltage Measurement... 23:00:03 Voltage Offset Correction: v_off_ini = 0.000005377 V, v_off_fin = -0.000001436 V 23:00:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319337 Vs 23:00:06 Temperature Measurement, Probe Number = 0, T = 20.195000 C 23:00:06 Temperature Measurement, Probe Number = 1, T = 20.066000 C 23:00:07 Temperature Measurement, Probe Number = 2, T = 20.040000 C 23:00:08 Temperature Measurement, Probe Number = 3, T = 20.007000 C 23:00:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 23:00:08 Integrated Voltage Measurement... 23:00:27 Voltage Offset Correction: v_off_ini = 0.000001538 V, v_off_fin = 0.000006052 V 23:00:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447465 Vs 23:00:27 Integrated Voltage Measurement... 23:00:47 Voltage Offset Correction: v_off_ini = 0.000004971 V, v_off_fin = -0.000001433 V 23:00:47 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175322924 Vs 23:00:49 Temperature Measurement, Probe Number = 0, T = 20.197000 C 23:00:50 Temperature Measurement, Probe Number = 1, T = 20.070000 C 23:00:51 Temperature Measurement, Probe Number = 2, T = 20.042000 C 23:00:51 Temperature Measurement, Probe Number = 3, T = 20.006000 C 23:00:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 23:00:52 Integrated Voltage Measurement... 23:01:11 Voltage Offset Correction: v_off_ini = 0.000001872 V, v_off_fin = 0.000006127 V 23:01:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175449986 Vs 23:01:11 Integrated Voltage Measurement... 23:01:31 Voltage Offset Correction: v_off_ini = 0.000005380 V, v_off_fin = -0.000001541 V 23:01:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319578 Vs 23:01:33 Temperature Measurement, Probe Number = 0, T = 20.202000 C 23:01:34 Temperature Measurement, Probe Number = 1, T = 20.064000 C 23:01:35 Temperature Measurement, Probe Number = 2, T = 20.034000 C 23:01:35 Temperature Measurement, Probe Number = 3, T = 20.004000 C 23:01:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:01:36 Integrated Voltage Measurement... 23:01:55 Voltage Offset Correction: v_off_ini = 0.000002097 V, v_off_fin = 0.000006190 V 23:01:56 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175448144 Vs 23:01:56 Integrated Voltage Measurement... 23:02:15 Voltage Offset Correction: v_off_ini = 0.000005715 V, v_off_fin = -0.000001126 V 23:02:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317258 Vs 23:32:18 Temperature Measurement, Probe Number = 0, T = 20.171000 C 23:32:19 Temperature Measurement, Probe Number = 1, T = 20.061000 C 23:32:19 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:32:20 Temperature Measurement, Probe Number = 3, T = 19.998000 C 23:32:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:32:20 Integrated Voltage Measurement... 23:32:40 Voltage Offset Correction: v_off_ini = 0.000003798 V, v_off_fin = 0.000006491 V 23:32:40 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175538031 Vs 23:32:40 Integrated Voltage Measurement... 23:32:59 Voltage Offset Correction: v_off_ini = 0.000005555 V, v_off_fin = -0.000001374 V 23:32:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315022 Vs 23:33:02 Temperature Measurement, Probe Number = 0, T = 20.164000 C 23:33:02 Temperature Measurement, Probe Number = 1, T = 20.064000 C 23:33:03 Temperature Measurement, Probe Number = 2, T = 20.033000 C 23:33:04 Temperature Measurement, Probe Number = 3, T = 20.000000 C 23:33:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:33:04 Integrated Voltage Measurement... 23:33:23 Voltage Offset Correction: v_off_ini = 0.000002430 V, v_off_fin = 0.000006451 V 23:33:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175460717 Vs 23:33:23 Integrated Voltage Measurement... 23:33:43 Voltage Offset Correction: v_off_ini = 0.000005561 V, v_off_fin = -0.000001603 V 23:33:43 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175322869 Vs 23:33:46 Temperature Measurement, Probe Number = 0, T = 20.175000 C 23:33:46 Temperature Measurement, Probe Number = 1, T = 20.060000 C 23:33:47 Temperature Measurement, Probe Number = 2, T = 20.032000 C 23:33:48 Temperature Measurement, Probe Number = 3, T = 20.001000 C 23:33:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:33:48 Integrated Voltage Measurement... 23:34:07 Voltage Offset Correction: v_off_ini = 0.000002129 V, v_off_fin = 0.000006523 V 23:34:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175454195 Vs 23:34:07 Integrated Voltage Measurement... 23:34:27 Voltage Offset Correction: v_off_ini = 0.000005935 V, v_off_fin = -0.000001227 V 23:34:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175322444 Vs 23:34:29 Temperature Measurement, Probe Number = 0, T = 20.206000 C 23:34:30 Temperature Measurement, Probe Number = 1, T = 20.061000 C 23:34:31 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:34:31 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:34:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:34:32 Integrated Voltage Measurement... 23:34:51 Voltage Offset Correction: v_off_ini = 0.000001431 V, v_off_fin = 0.000006314 V 23:34:51 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175450541 Vs 23:34:51 Integrated Voltage Measurement... 23:35:11 Voltage Offset Correction: v_off_ini = 0.000005582 V, v_off_fin = -0.000002154 V 23:35:11 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175329188 Vs 23:35:14 Temperature Measurement, Probe Number = 0, T = 20.257000 C 23:35:14 Temperature Measurement, Probe Number = 1, T = 20.058000 C 23:35:15 Temperature Measurement, Probe Number = 2, T = 20.030000 C 23:35:16 Temperature Measurement, Probe Number = 3, T = 19.998000 C 23:35:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:35:16 Integrated Voltage Measurement... 23:35:35 Voltage Offset Correction: v_off_ini = 0.000001958 V, v_off_fin = 0.000006130 V 23:35:35 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175453252 Vs 23:35:35 Integrated Voltage Measurement... 23:35:55 Voltage Offset Correction: v_off_ini = 0.000005265 V, v_off_fin = -0.000001292 V 23:35:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175328030 Vs 23:35:58 Temperature Measurement, Probe Number = 0, T = 20.254000 C 23:35:58 Temperature Measurement, Probe Number = 1, T = 20.061000 C 23:35:59 Temperature Measurement, Probe Number = 2, T = 20.032000 C 23:35:59 Temperature Measurement, Probe Number = 3, T = 20.003000 C 23:36:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:36:00 Integrated Voltage Measurement... 23:36:19 Voltage Offset Correction: v_off_ini = 0.000001894 V, v_off_fin = 0.000006214 V 23:36:19 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175449600 Vs 23:36:19 Integrated Voltage Measurement... 23:36:39 Voltage Offset Correction: v_off_ini = 0.000006188 V, v_off_fin = -0.000000870 V 23:36:39 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175318467 Vs 23:36:42 Temperature Measurement, Probe Number = 0, T = 20.272000 C 23:36:43 Temperature Measurement, Probe Number = 1, T = 20.060000 C 23:36:43 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:36:44 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:36:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:36:44 Integrated Voltage Measurement... 23:37:03 Voltage Offset Correction: v_off_ini = 0.000002193 V, v_off_fin = 0.000006060 V 23:37:03 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175440829 Vs 23:37:03 Integrated Voltage Measurement... 23:37:22 Voltage Offset Correction: v_off_ini = 0.000006180 V, v_off_fin = -0.000001142 V 23:37:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316487 Vs 23:37:25 Temperature Measurement, Probe Number = 0, T = 20.226000 C 23:37:26 Temperature Measurement, Probe Number = 1, T = 20.059000 C 23:37:26 Temperature Measurement, Probe Number = 2, T = 20.030000 C 23:37:27 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:37:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:37:27 Integrated Voltage Measurement... 23:37:46 Voltage Offset Correction: v_off_ini = 0.000001805 V, v_off_fin = 0.000006065 V 23:37:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175457236 Vs 23:37:47 Integrated Voltage Measurement... 23:38:06 Voltage Offset Correction: v_off_ini = 0.000005411 V, v_off_fin = -0.000001749 V 23:38:06 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175325393 Vs 23:38:09 Temperature Measurement, Probe Number = 0, T = 20.231000 C 23:38:09 Temperature Measurement, Probe Number = 1, T = 20.062000 C 23:38:10 Temperature Measurement, Probe Number = 2, T = 20.034000 C 23:38:11 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:38:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:38:11 Integrated Voltage Measurement... 23:38:30 Voltage Offset Correction: v_off_ini = 0.000001817 V, v_off_fin = 0.000005939 V 23:38:30 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175447600 Vs 23:38:30 Integrated Voltage Measurement... 23:38:49 Voltage Offset Correction: v_off_ini = 0.000005102 V, v_off_fin = -0.000001959 V 23:38:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322981 Vs 23:38:52 Temperature Measurement, Probe Number = 0, T = 20.213000 C 23:38:53 Temperature Measurement, Probe Number = 1, T = 20.060000 C 23:38:54 Temperature Measurement, Probe Number = 2, T = 20.029000 C 23:38:54 Temperature Measurement, Probe Number = 3, T = 20.001000 C 23:38:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 23:38:55 Integrated Voltage Measurement... 23:39:14 Voltage Offset Correction: v_off_ini = 0.000001747 V, v_off_fin = 0.000006005 V 23:39:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448281 Vs 23:39:14 Integrated Voltage Measurement... 23:39:33 Voltage Offset Correction: v_off_ini = 0.000005622 V, v_off_fin = -0.000001600 V 23:39:33 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175328697 Vs 00:09:36 Temperature Measurement, Probe Number = 0, T = 20.162000 C 00:09:37 Temperature Measurement, Probe Number = 1, T = 20.056000 C 00:09:37 Temperature Measurement, Probe Number = 2, T = 20.027000 C 00:09:38 Temperature Measurement, Probe Number = 3, T = 19.996000 C 00:09:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:09:38 Integrated Voltage Measurement... 00:09:57 Voltage Offset Correction: v_off_ini = 0.000002799 V, v_off_fin = 0.000005560 V 00:09:57 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175530045 Vs 00:09:58 Integrated Voltage Measurement... 00:10:17 Voltage Offset Correction: v_off_ini = 0.000004812 V, v_off_fin = -0.000001602 V 00:10:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325898 Vs 00:10:20 Temperature Measurement, Probe Number = 0, T = 20.240000 C 00:10:21 Temperature Measurement, Probe Number = 1, T = 20.060000 C 00:10:21 Temperature Measurement, Probe Number = 2, T = 20.026000 C 00:10:22 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:10:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:10:22 Integrated Voltage Measurement... 00:10:41 Voltage Offset Correction: v_off_ini = 0.000000832 V, v_off_fin = 0.000006769 V 00:10:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175444157 Vs 00:10:42 Integrated Voltage Measurement... 00:11:01 Voltage Offset Correction: v_off_ini = 0.000005617 V, v_off_fin = -0.000001479 V 00:11:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175326253 Vs 00:11:04 Temperature Measurement, Probe Number = 0, T = 20.268000 C 00:11:04 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:11:05 Temperature Measurement, Probe Number = 2, T = 20.025000 C 00:11:06 Temperature Measurement, Probe Number = 3, T = 19.995000 C 00:11:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 00:11:06 Integrated Voltage Measurement... 00:11:25 Voltage Offset Correction: v_off_ini = 0.000001582 V, v_off_fin = 0.000006176 V 00:11:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434844 Vs 00:11:25 Integrated Voltage Measurement... 00:11:44 Voltage Offset Correction: v_off_ini = 0.000005234 V, v_off_fin = -0.000001734 V 00:11:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310504 Vs 00:11:47 Temperature Measurement, Probe Number = 0, T = 20.257000 C 00:11:48 Temperature Measurement, Probe Number = 1, T = 20.054000 C 00:11:49 Temperature Measurement, Probe Number = 2, T = 20.026000 C 00:11:49 Temperature Measurement, Probe Number = 3, T = 19.993000 C 00:11:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:11:49 Integrated Voltage Measurement... 00:12:08 Voltage Offset Correction: v_off_ini = 0.000001672 V, v_off_fin = 0.000005942 V 00:12:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439941 Vs 00:12:09 Integrated Voltage Measurement... 00:12:28 Voltage Offset Correction: v_off_ini = 0.000005491 V, v_off_fin = -0.000002794 V 00:12:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323801 Vs 00:12:31 Temperature Measurement, Probe Number = 0, T = 20.202000 C 00:12:31 Temperature Measurement, Probe Number = 1, T = 20.056000 C 00:12:32 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:12:33 Temperature Measurement, Probe Number = 3, T = 19.995000 C 00:12:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:12:33 Integrated Voltage Measurement... 00:12:52 Voltage Offset Correction: v_off_ini = 0.000001434 V, v_off_fin = 0.000005664 V 00:12:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434293 Vs 00:12:53 Integrated Voltage Measurement... 00:13:12 Voltage Offset Correction: v_off_ini = 0.000005053 V, v_off_fin = -0.000002227 V 00:13:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313501 Vs 00:13:14 Temperature Measurement, Probe Number = 0, T = 20.193000 C 00:13:15 Temperature Measurement, Probe Number = 1, T = 20.055000 C 00:13:16 Temperature Measurement, Probe Number = 2, T = 20.030000 C 00:13:16 Temperature Measurement, Probe Number = 3, T = 19.996000 C 00:13:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:13:17 Integrated Voltage Measurement... 00:13:36 Voltage Offset Correction: v_off_ini = 0.000001247 V, v_off_fin = 0.000006360 V 00:13:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433804 Vs 00:13:36 Integrated Voltage Measurement... 00:13:55 Voltage Offset Correction: v_off_ini = 0.000005385 V, v_off_fin = -0.000001827 V 00:13:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315612 Vs 00:13:58 Temperature Measurement, Probe Number = 0, T = 20.191000 C 00:13:59 Temperature Measurement, Probe Number = 1, T = 20.053000 C 00:13:59 Temperature Measurement, Probe Number = 2, T = 20.026000 C 00:14:00 Temperature Measurement, Probe Number = 3, T = 19.992000 C 00:14:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:14:00 Integrated Voltage Measurement... 00:14:20 Voltage Offset Correction: v_off_ini = 0.000000975 V, v_off_fin = 0.000005555 V 00:14:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433003 Vs 00:14:21 Integrated Voltage Measurement... 00:14:40 Voltage Offset Correction: v_off_ini = 0.000004921 V, v_off_fin = -0.000002136 V 00:14:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316746 Vs 00:14:43 Temperature Measurement, Probe Number = 0, T = 20.133000 C 00:14:43 Temperature Measurement, Probe Number = 1, T = 20.054000 C 00:14:44 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:14:45 Temperature Measurement, Probe Number = 3, T = 19.993000 C 00:14:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:14:45 Integrated Voltage Measurement... 00:15:04 Voltage Offset Correction: v_off_ini = 0.000001717 V, v_off_fin = 0.000005545 V 00:15:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432717 Vs 00:15:04 Integrated Voltage Measurement... 00:15:23 Voltage Offset Correction: v_off_ini = 0.000004644 V, v_off_fin = -0.000001926 V 00:15:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321512 Vs 00:15:26 Temperature Measurement, Probe Number = 0, T = 20.118000 C 00:15:27 Temperature Measurement, Probe Number = 1, T = 20.056000 C 00:15:28 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:15:28 Temperature Measurement, Probe Number = 3, T = 19.994000 C 00:15:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:15:28 Integrated Voltage Measurement... 00:15:48 Voltage Offset Correction: v_off_ini = 0.000001728 V, v_off_fin = 0.000006011 V 00:15:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433339 Vs 00:15:48 Integrated Voltage Measurement... 00:16:07 Voltage Offset Correction: v_off_ini = 0.000005033 V, v_off_fin = -0.000001780 V 00:16:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314470 Vs 00:16:10 Temperature Measurement, Probe Number = 0, T = 20.164000 C 00:16:10 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:16:11 Temperature Measurement, Probe Number = 2, T = 20.026000 C 00:16:12 Temperature Measurement, Probe Number = 3, T = 19.994000 C 00:16:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:16:12 Integrated Voltage Measurement... 00:16:31 Voltage Offset Correction: v_off_ini = 0.000001405 V, v_off_fin = 0.000006302 V 00:16:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443574 Vs 00:16:31 Integrated Voltage Measurement... 00:16:50 Voltage Offset Correction: v_off_ini = 0.000005852 V, v_off_fin = -0.000002197 V 00:16:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319995 Vs 00:46:53 Temperature Measurement, Probe Number = 0, T = 20.265000 C 00:46:54 Temperature Measurement, Probe Number = 1, T = 20.055000 C 00:46:55 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:46:55 Temperature Measurement, Probe Number = 3, T = 19.995000 C 00:46:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:46:56 Integrated Voltage Measurement... 00:47:15 Voltage Offset Correction: v_off_ini = 0.000004328 V, v_off_fin = 0.000006377 V 00:47:15 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175531441 Vs 00:47:15 Integrated Voltage Measurement... 00:47:34 Voltage Offset Correction: v_off_ini = 0.000005305 V, v_off_fin = -0.000001645 V 00:47:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315603 Vs 00:47:37 Temperature Measurement, Probe Number = 0, T = 20.264000 C 00:47:38 Temperature Measurement, Probe Number = 1, T = 20.054000 C 00:47:39 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:47:39 Temperature Measurement, Probe Number = 3, T = 19.996000 C 00:47:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:47:39 Integrated Voltage Measurement... 00:47:59 Voltage Offset Correction: v_off_ini = 0.000000724 V, v_off_fin = 0.000006203 V 00:47:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438137 Vs 00:47:59 Integrated Voltage Measurement... 00:48:19 Voltage Offset Correction: v_off_ini = 0.000005100 V, v_off_fin = -0.000002594 V 00:48:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315458 Vs 00:48:22 Temperature Measurement, Probe Number = 0, T = 20.295000 C 00:48:22 Temperature Measurement, Probe Number = 1, T = 20.053000 C 00:48:23 Temperature Measurement, Probe Number = 2, T = 20.026000 C 00:48:23 Temperature Measurement, Probe Number = 3, T = 19.994000 C 00:48:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:48:24 Integrated Voltage Measurement... 00:48:43 Voltage Offset Correction: v_off_ini = 0.000000946 V, v_off_fin = 0.000005928 V 00:48:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430390 Vs 00:48:43 Integrated Voltage Measurement... 00:49:03 Voltage Offset Correction: v_off_ini = 0.000005089 V, v_off_fin = -0.000001694 V 00:49:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316107 Vs 00:49:05 Temperature Measurement, Probe Number = 0, T = 20.265000 C 00:49:06 Temperature Measurement, Probe Number = 1, T = 20.056000 C 00:49:07 Temperature Measurement, Probe Number = 2, T = 20.027000 C 00:49:07 Temperature Measurement, Probe Number = 3, T = 19.993000 C 00:49:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:49:07 Integrated Voltage Measurement... 00:49:27 Voltage Offset Correction: v_off_ini = 0.000000616 V, v_off_fin = 0.000005889 V 00:49:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430637 Vs 00:49:27 Integrated Voltage Measurement... 00:49:46 Voltage Offset Correction: v_off_ini = 0.000005145 V, v_off_fin = -0.000002912 V 00:49:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312001 Vs 00:49:49 Temperature Measurement, Probe Number = 0, T = 20.235000 C 00:49:49 Temperature Measurement, Probe Number = 1, T = 20.057000 C 00:49:50 Temperature Measurement, Probe Number = 2, T = 20.030000 C 00:49:51 Temperature Measurement, Probe Number = 3, T = 19.993000 C 00:49:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 00:49:51 Integrated Voltage Measurement... 00:50:10 Voltage Offset Correction: v_off_ini = 0.000001103 V, v_off_fin = 0.000006014 V 00:50:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429114 Vs 00:50:10 Integrated Voltage Measurement... 00:50:30 Voltage Offset Correction: v_off_ini = 0.000005318 V, v_off_fin = -0.000001990 V 00:50:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313446 Vs 00:50:33 Temperature Measurement, Probe Number = 0, T = 20.260000 C 00:50:33 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:50:34 Temperature Measurement, Probe Number = 2, T = 20.029000 C 00:50:35 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:50:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:50:35 Integrated Voltage Measurement... 00:50:54 Voltage Offset Correction: v_off_ini = 0.000001699 V, v_off_fin = 0.000006458 V 00:50:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429177 Vs 00:50:54 Integrated Voltage Measurement... 00:51:14 Voltage Offset Correction: v_off_ini = 0.000006046 V, v_off_fin = -0.000001537 V 00:51:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310331 Vs 00:51:17 Temperature Measurement, Probe Number = 0, T = 20.296000 C 00:51:17 Temperature Measurement, Probe Number = 1, T = 20.058000 C 00:51:18 Temperature Measurement, Probe Number = 2, T = 20.031000 C 00:51:18 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:51:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:51:19 Integrated Voltage Measurement... 00:51:38 Voltage Offset Correction: v_off_ini = 0.000001897 V, v_off_fin = 0.000006159 V 00:51:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432897 Vs 00:51:38 Integrated Voltage Measurement... 00:51:58 Voltage Offset Correction: v_off_ini = 0.000005670 V, v_off_fin = -0.000001320 V 00:51:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312931 Vs 00:52:01 Temperature Measurement, Probe Number = 0, T = 20.322000 C 00:52:02 Temperature Measurement, Probe Number = 1, T = 20.059000 C 00:52:02 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:52:03 Temperature Measurement, Probe Number = 3, T = 19.999000 C 00:52:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:52:03 Integrated Voltage Measurement... 00:52:22 Voltage Offset Correction: v_off_ini = 0.000001814 V, v_off_fin = 0.000007227 V 00:52:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438838 Vs 00:52:23 Integrated Voltage Measurement... 00:52:42 Voltage Offset Correction: v_off_ini = 0.000006183 V, v_off_fin = -0.000001397 V 00:52:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309961 Vs 00:52:45 Temperature Measurement, Probe Number = 0, T = 20.312000 C 00:52:45 Temperature Measurement, Probe Number = 1, T = 20.061000 C 00:52:46 Temperature Measurement, Probe Number = 2, T = 20.032000 C 00:52:47 Temperature Measurement, Probe Number = 3, T = 20.000000 C 00:52:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:52:47 Integrated Voltage Measurement... 00:53:06 Voltage Offset Correction: v_off_ini = 0.000002706 V, v_off_fin = 0.000006547 V 00:53:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435313 Vs 00:53:07 Integrated Voltage Measurement... 00:53:26 Voltage Offset Correction: v_off_ini = 0.000006183 V, v_off_fin = -0.000002165 V 00:53:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311112 Vs 00:53:29 Temperature Measurement, Probe Number = 0, T = 20.296000 C 00:53:30 Temperature Measurement, Probe Number = 1, T = 20.055000 C 00:53:30 Temperature Measurement, Probe Number = 2, T = 20.028000 C 00:53:31 Temperature Measurement, Probe Number = 3, T = 19.995000 C 00:53:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 00:53:31 Integrated Voltage Measurement... 00:53:50 Voltage Offset Correction: v_off_ini = 0.000001730 V, v_off_fin = 0.000006391 V 00:53:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436164 Vs 00:53:50 Integrated Voltage Measurement... 00:54:09 Voltage Offset Correction: v_off_ini = 0.000005605 V, v_off_fin = -0.000001749 V 00:54:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312554 Vs 01:24:12 Temperature Measurement, Probe Number = 0, T = 20.276000 C 01:24:13 Temperature Measurement, Probe Number = 1, T = 20.053000 C 01:24:13 Temperature Measurement, Probe Number = 2, T = 20.030000 C 01:24:14 Temperature Measurement, Probe Number = 3, T = 19.992000 C 01:24:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:24:14 Integrated Voltage Measurement... 01:24:35 Voltage Offset Correction: v_off_ini = 0.000004635 V, v_off_fin = 0.000006088 V 01:24:35 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175541768 Vs 01:24:36 Integrated Voltage Measurement... 01:24:56 Voltage Offset Correction: v_off_ini = 0.000005769 V, v_off_fin = -0.000001052 V 01:24:56 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175305061 Vs 01:24:58 Temperature Measurement, Probe Number = 0, T = 20.265000 C 01:24:59 Temperature Measurement, Probe Number = 1, T = 20.054000 C 01:25:00 Temperature Measurement, Probe Number = 2, T = 20.029000 C 01:25:00 Temperature Measurement, Probe Number = 3, T = 19.993000 C 01:25:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:25:01 Integrated Voltage Measurement... 01:25:20 Voltage Offset Correction: v_off_ini = 0.000002381 V, v_off_fin = 0.000006417 V 01:25:20 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175435005 Vs 01:25:21 Integrated Voltage Measurement... 01:25:40 Voltage Offset Correction: v_off_ini = 0.000005327 V, v_off_fin = -0.000001706 V 01:25:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320094 Vs 01:25:43 Temperature Measurement, Probe Number = 0, T = 20.250000 C 01:25:44 Temperature Measurement, Probe Number = 1, T = 20.056000 C 01:25:44 Temperature Measurement, Probe Number = 2, T = 20.026000 C 01:25:45 Temperature Measurement, Probe Number = 3, T = 19.991000 C 01:25:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:25:45 Integrated Voltage Measurement... 01:26:04 Voltage Offset Correction: v_off_ini = 0.000001592 V, v_off_fin = 0.000005987 V 01:26:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431764 Vs 01:26:05 Integrated Voltage Measurement... 01:26:24 Voltage Offset Correction: v_off_ini = 0.000004771 V, v_off_fin = -0.000002272 V 01:26:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318578 Vs 01:26:27 Temperature Measurement, Probe Number = 0, T = 20.160000 C 01:26:28 Temperature Measurement, Probe Number = 1, T = 20.055000 C 01:26:28 Temperature Measurement, Probe Number = 2, T = 20.026000 C 01:26:29 Temperature Measurement, Probe Number = 3, T = 19.990000 C 01:26:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:26:29 Integrated Voltage Measurement... 01:26:48 Voltage Offset Correction: v_off_ini = 0.000001911 V, v_off_fin = 0.000006426 V 01:26:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436102 Vs 01:26:49 Integrated Voltage Measurement... 01:27:08 Voltage Offset Correction: v_off_ini = 0.000005762 V, v_off_fin = -0.000002240 V 01:27:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313331 Vs 01:27:11 Temperature Measurement, Probe Number = 0, T = 20.171000 C 01:27:12 Temperature Measurement, Probe Number = 1, T = 20.054000 C 01:27:12 Temperature Measurement, Probe Number = 2, T = 20.028000 C 01:27:13 Temperature Measurement, Probe Number = 3, T = 19.994000 C 01:27:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:27:13 Integrated Voltage Measurement... 01:27:32 Voltage Offset Correction: v_off_ini = 0.000001321 V, v_off_fin = 0.000005312 V 01:27:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424571 Vs 01:27:32 Integrated Voltage Measurement... 01:27:51 Voltage Offset Correction: v_off_ini = 0.000005129 V, v_off_fin = -0.000002138 V 01:27:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309595 Vs 01:27:54 Temperature Measurement, Probe Number = 0, T = 20.202000 C 01:27:55 Temperature Measurement, Probe Number = 1, T = 20.053000 C 01:27:56 Temperature Measurement, Probe Number = 2, T = 20.027000 C 01:27:56 Temperature Measurement, Probe Number = 3, T = 19.991000 C 01:27:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:27:56 Integrated Voltage Measurement... 01:28:15 Voltage Offset Correction: v_off_ini = 0.000000830 V, v_off_fin = 0.000006104 V 01:28:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432842 Vs 01:28:16 Integrated Voltage Measurement... 01:28:35 Voltage Offset Correction: v_off_ini = 0.000005130 V, v_off_fin = -0.000001447 V 01:28:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317674 Vs 01:28:38 Temperature Measurement, Probe Number = 0, T = 20.231000 C 01:28:39 Temperature Measurement, Probe Number = 1, T = 20.053000 C 01:28:39 Temperature Measurement, Probe Number = 2, T = 20.030000 C 01:28:40 Temperature Measurement, Probe Number = 3, T = 19.992000 C 01:28:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:28:40 Integrated Voltage Measurement... 01:29:00 Voltage Offset Correction: v_off_ini = 0.000001113 V, v_off_fin = 0.000006283 V 01:29:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430111 Vs 01:29:00 Integrated Voltage Measurement... 01:29:19 Voltage Offset Correction: v_off_ini = 0.000005030 V, v_off_fin = -0.000002367 V 01:29:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318305 Vs 01:29:22 Temperature Measurement, Probe Number = 0, T = 20.260000 C 01:29:23 Temperature Measurement, Probe Number = 1, T = 20.054000 C 01:29:24 Temperature Measurement, Probe Number = 2, T = 20.029000 C 01:29:24 Temperature Measurement, Probe Number = 3, T = 19.994000 C 01:29:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:29:24 Integrated Voltage Measurement... 01:29:44 Voltage Offset Correction: v_off_ini = 0.000001223 V, v_off_fin = 0.000006227 V 01:29:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430775 Vs 01:29:45 Integrated Voltage Measurement... 01:30:04 Voltage Offset Correction: v_off_ini = 0.000004813 V, v_off_fin = -0.000002418 V 01:30:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306798 Vs 01:30:06 Temperature Measurement, Probe Number = 0, T = 20.261000 C 01:30:07 Temperature Measurement, Probe Number = 1, T = 20.054000 C 01:30:08 Temperature Measurement, Probe Number = 2, T = 20.026000 C 01:30:08 Temperature Measurement, Probe Number = 3, T = 19.991000 C 01:30:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:30:09 Integrated Voltage Measurement... 01:30:28 Voltage Offset Correction: v_off_ini = 0.000000930 V, v_off_fin = 0.000006145 V 01:30:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429169 Vs 01:30:28 Integrated Voltage Measurement... 01:30:47 Voltage Offset Correction: v_off_ini = 0.000004948 V, v_off_fin = -0.000001602 V 01:30:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309395 Vs 01:30:50 Temperature Measurement, Probe Number = 0, T = 20.307000 C 01:30:51 Temperature Measurement, Probe Number = 1, T = 20.055000 C 01:30:51 Temperature Measurement, Probe Number = 2, T = 20.027000 C 01:30:52 Temperature Measurement, Probe Number = 3, T = 19.994000 C 01:30:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 01:30:52 Integrated Voltage Measurement... 01:31:11 Voltage Offset Correction: v_off_ini = 0.000001599 V, v_off_fin = 0.000005915 V 01:31:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439148 Vs 01:31:12 Integrated Voltage Measurement... 01:31:31 Voltage Offset Correction: v_off_ini = 0.000005204 V, v_off_fin = -0.000001772 V 01:31:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306163 Vs 02:01:34 Temperature Measurement, Probe Number = 0, T = 20.258000 C 02:01:35 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:01:35 Temperature Measurement, Probe Number = 2, T = 20.018000 C 02:01:36 Temperature Measurement, Probe Number = 3, T = 19.986000 C 02:01:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:01:36 Integrated Voltage Measurement... 02:01:55 Voltage Offset Correction: v_off_ini = 0.000003792 V, v_off_fin = 0.000005841 V 02:01:55 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175524137 Vs 02:01:55 Integrated Voltage Measurement... 02:02:15 Voltage Offset Correction: v_off_ini = 0.000005308 V, v_off_fin = -0.000001665 V 02:02:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304805 Vs 02:02:17 Temperature Measurement, Probe Number = 0, T = 20.242000 C 02:02:18 Temperature Measurement, Probe Number = 1, T = 20.047000 C 02:02:19 Temperature Measurement, Probe Number = 2, T = 20.016000 C 02:02:19 Temperature Measurement, Probe Number = 3, T = 19.986000 C 02:02:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:02:20 Integrated Voltage Measurement... 02:02:39 Voltage Offset Correction: v_off_ini = 0.000002076 V, v_off_fin = 0.000005897 V 02:02:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430525 Vs 02:02:39 Integrated Voltage Measurement... 02:02:58 Voltage Offset Correction: v_off_ini = 0.000005012 V, v_off_fin = -0.000001516 V 02:02:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308790 Vs 02:03:01 Temperature Measurement, Probe Number = 0, T = 20.278000 C 02:03:02 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:03:03 Temperature Measurement, Probe Number = 2, T = 20.016000 C 02:03:03 Temperature Measurement, Probe Number = 3, T = 19.987000 C 02:03:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:03:03 Integrated Voltage Measurement... 02:03:23 Voltage Offset Correction: v_off_ini = 0.000001564 V, v_off_fin = 0.000006017 V 02:03:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432098 Vs 02:03:23 Integrated Voltage Measurement... 02:03:42 Voltage Offset Correction: v_off_ini = 0.000004964 V, v_off_fin = -0.000001937 V 02:03:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322737 Vs 02:03:45 Temperature Measurement, Probe Number = 0, T = 20.283000 C 02:03:46 Temperature Measurement, Probe Number = 1, T = 20.052000 C 02:03:47 Temperature Measurement, Probe Number = 2, T = 20.018000 C 02:03:47 Temperature Measurement, Probe Number = 3, T = 19.987000 C 02:03:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:03:47 Integrated Voltage Measurement... 02:04:07 Voltage Offset Correction: v_off_ini = 0.000001061 V, v_off_fin = 0.000005876 V 02:04:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423239 Vs 02:04:07 Integrated Voltage Measurement... 02:04:26 Voltage Offset Correction: v_off_ini = 0.000005021 V, v_off_fin = -0.000001990 V 02:04:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311369 Vs 02:04:29 Temperature Measurement, Probe Number = 0, T = 20.262000 C 02:04:30 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:04:31 Temperature Measurement, Probe Number = 2, T = 20.018000 C 02:04:31 Temperature Measurement, Probe Number = 3, T = 19.984000 C 02:04:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:04:31 Integrated Voltage Measurement... 02:04:51 Voltage Offset Correction: v_off_ini = 0.000001247 V, v_off_fin = 0.000006021 V 02:04:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427572 Vs 02:04:51 Integrated Voltage Measurement... 02:05:10 Voltage Offset Correction: v_off_ini = 0.000005699 V, v_off_fin = -0.000002058 V 02:05:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305452 Vs 02:05:13 Temperature Measurement, Probe Number = 0, T = 20.241000 C 02:05:13 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:05:14 Temperature Measurement, Probe Number = 2, T = 20.018000 C 02:05:15 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:05:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:05:15 Integrated Voltage Measurement... 02:05:34 Voltage Offset Correction: v_off_ini = 0.000001810 V, v_off_fin = 0.000005919 V 02:05:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433448 Vs 02:05:34 Integrated Voltage Measurement... 02:05:54 Voltage Offset Correction: v_off_ini = 0.000005570 V, v_off_fin = -0.000001987 V 02:05:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309586 Vs 02:05:56 Temperature Measurement, Probe Number = 0, T = 20.197000 C 02:05:57 Temperature Measurement, Probe Number = 1, T = 20.047000 C 02:05:58 Temperature Measurement, Probe Number = 2, T = 20.018000 C 02:05:58 Temperature Measurement, Probe Number = 3, T = 19.984000 C 02:05:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:05:59 Integrated Voltage Measurement... 02:06:18 Voltage Offset Correction: v_off_ini = 0.000001539 V, v_off_fin = 0.000005651 V 02:06:18 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424560 Vs 02:06:18 Integrated Voltage Measurement... 02:06:37 Voltage Offset Correction: v_off_ini = 0.000004823 V, v_off_fin = -0.000002467 V 02:06:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314185 Vs 02:06:40 Temperature Measurement, Probe Number = 0, T = 20.178000 C 02:06:41 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:06:41 Temperature Measurement, Probe Number = 2, T = 20.025000 C 02:06:42 Temperature Measurement, Probe Number = 3, T = 19.986000 C 02:06:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:06:42 Integrated Voltage Measurement... 02:07:01 Voltage Offset Correction: v_off_ini = 0.000001402 V, v_off_fin = 0.000006113 V 02:07:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429226 Vs 02:07:02 Integrated Voltage Measurement... 02:07:21 Voltage Offset Correction: v_off_ini = 0.000005142 V, v_off_fin = -0.000001763 V 02:07:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316145 Vs 02:07:24 Temperature Measurement, Probe Number = 0, T = 20.234000 C 02:07:25 Temperature Measurement, Probe Number = 1, T = 20.053000 C 02:07:25 Temperature Measurement, Probe Number = 2, T = 20.027000 C 02:07:26 Temperature Measurement, Probe Number = 3, T = 19.989000 C 02:07:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 02:07:26 Integrated Voltage Measurement... 02:07:45 Voltage Offset Correction: v_off_ini = 0.000001833 V, v_off_fin = 0.000005457 V 02:07:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423185 Vs 02:07:45 Integrated Voltage Measurement... 02:08:04 Voltage Offset Correction: v_off_ini = 0.000004814 V, v_off_fin = -0.000002263 V 02:08:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313114 Vs 02:08:07 Temperature Measurement, Probe Number = 0, T = 20.249000 C 02:08:08 Temperature Measurement, Probe Number = 1, T = 20.050000 C 02:08:08 Temperature Measurement, Probe Number = 2, T = 20.023000 C 02:08:09 Temperature Measurement, Probe Number = 3, T = 19.989000 C 02:08:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:08:09 Integrated Voltage Measurement... 02:08:28 Voltage Offset Correction: v_off_ini = 0.000001427 V, v_off_fin = 0.000005877 V 02:08:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432554 Vs 02:08:29 Integrated Voltage Measurement... 02:08:48 Voltage Offset Correction: v_off_ini = 0.000004745 V, v_off_fin = -0.000002217 V 02:08:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320291 Vs 02:38:51 Temperature Measurement, Probe Number = 0, T = 20.213000 C 02:38:52 Temperature Measurement, Probe Number = 1, T = 20.047000 C 02:38:52 Temperature Measurement, Probe Number = 2, T = 20.022000 C 02:38:53 Temperature Measurement, Probe Number = 3, T = 19.985000 C 02:38:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:38:53 Integrated Voltage Measurement... 02:39:13 Voltage Offset Correction: v_off_ini = 0.000003418 V, v_off_fin = 0.000005766 V 02:39:13 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175514985 Vs 02:39:13 Integrated Voltage Measurement... 02:39:33 Voltage Offset Correction: v_off_ini = 0.000005289 V, v_off_fin = -0.000001763 V 02:39:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311027 Vs 02:39:36 Temperature Measurement, Probe Number = 0, T = 20.216000 C 02:39:36 Temperature Measurement, Probe Number = 1, T = 20.047000 C 02:39:37 Temperature Measurement, Probe Number = 2, T = 20.023000 C 02:39:37 Temperature Measurement, Probe Number = 3, T = 19.984000 C 02:39:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:39:38 Integrated Voltage Measurement... 02:39:57 Voltage Offset Correction: v_off_ini = 0.000001971 V, v_off_fin = 0.000005758 V 02:39:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428794 Vs 02:39:57 Integrated Voltage Measurement... 02:40:16 Voltage Offset Correction: v_off_ini = 0.000005222 V, v_off_fin = -0.000001741 V 02:40:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303057 Vs 02:40:19 Temperature Measurement, Probe Number = 0, T = 20.208000 C 02:40:20 Temperature Measurement, Probe Number = 1, T = 20.049000 C 02:40:21 Temperature Measurement, Probe Number = 2, T = 20.022000 C 02:40:21 Temperature Measurement, Probe Number = 3, T = 19.987000 C 02:40:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:40:21 Integrated Voltage Measurement... 02:40:40 Voltage Offset Correction: v_off_ini = 0.000001344 V, v_off_fin = 0.000006304 V 02:40:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432175 Vs 02:40:41 Integrated Voltage Measurement... 02:41:01 Voltage Offset Correction: v_off_ini = 0.000004783 V, v_off_fin = -0.000000811 V 02:41:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175306650 Vs 02:41:04 Temperature Measurement, Probe Number = 0, T = 20.204000 C 02:41:04 Temperature Measurement, Probe Number = 1, T = 20.044000 C 02:41:05 Temperature Measurement, Probe Number = 2, T = 20.017000 C 02:41:06 Temperature Measurement, Probe Number = 3, T = 19.981000 C 02:41:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:41:06 Integrated Voltage Measurement... 02:41:25 Voltage Offset Correction: v_off_ini = 0.000001253 V, v_off_fin = 0.000006026 V 02:41:25 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175413717 Vs 02:41:25 Integrated Voltage Measurement... 02:41:44 Voltage Offset Correction: v_off_ini = 0.000005412 V, v_off_fin = -0.000001678 V 02:41:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304494 Vs 02:41:47 Temperature Measurement, Probe Number = 0, T = 20.216000 C 02:41:48 Temperature Measurement, Probe Number = 1, T = 20.048000 C 02:41:48 Temperature Measurement, Probe Number = 2, T = 20.022000 C 02:41:49 Temperature Measurement, Probe Number = 3, T = 19.985000 C 02:41:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 02:41:49 Integrated Voltage Measurement... 02:42:08 Voltage Offset Correction: v_off_ini = 0.000001865 V, v_off_fin = 0.000006134 V 02:42:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435328 Vs 02:42:09 Integrated Voltage Measurement... 02:42:28 Voltage Offset Correction: v_off_ini = 0.000005286 V, v_off_fin = -0.000001662 V 02:42:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306534 Vs 02:42:31 Temperature Measurement, Probe Number = 0, T = 20.245000 C 02:42:32 Temperature Measurement, Probe Number = 1, T = 20.053000 C 02:42:32 Temperature Measurement, Probe Number = 2, T = 20.025000 C 02:42:33 Temperature Measurement, Probe Number = 3, T = 19.991000 C 02:42:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:42:33 Integrated Voltage Measurement... 02:42:52 Voltage Offset Correction: v_off_ini = 0.000001412 V, v_off_fin = 0.000006857 V 02:42:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431018 Vs 02:42:53 Integrated Voltage Measurement... 02:43:12 Voltage Offset Correction: v_off_ini = 0.000005495 V, v_off_fin = -0.000001860 V 02:43:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307130 Vs 02:43:15 Temperature Measurement, Probe Number = 0, T = 20.286000 C 02:43:16 Temperature Measurement, Probe Number = 1, T = 20.053000 C 02:43:16 Temperature Measurement, Probe Number = 2, T = 20.029000 C 02:43:17 Temperature Measurement, Probe Number = 3, T = 19.992000 C 02:43:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 02:43:17 Integrated Voltage Measurement... 02:43:36 Voltage Offset Correction: v_off_ini = 0.000001865 V, v_off_fin = 0.000006592 V 02:43:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428362 Vs 02:43:37 Integrated Voltage Measurement... 02:43:56 Voltage Offset Correction: v_off_ini = 0.000005226 V, v_off_fin = -0.000002460 V 02:43:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306199 Vs 02:43:59 Temperature Measurement, Probe Number = 0, T = 20.280000 C 02:44:00 Temperature Measurement, Probe Number = 1, T = 20.052000 C 02:44:00 Temperature Measurement, Probe Number = 2, T = 20.029000 C 02:44:01 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:44:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 02:44:01 Integrated Voltage Measurement... 02:44:21 Voltage Offset Correction: v_off_ini = 0.000001993 V, v_off_fin = 0.000006195 V 02:44:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433462 Vs 02:44:21 Integrated Voltage Measurement... 02:44:40 Voltage Offset Correction: v_off_ini = 0.000005689 V, v_off_fin = -0.000001354 V 02:44:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306459 Vs 02:44:43 Temperature Measurement, Probe Number = 0, T = 20.251000 C 02:44:44 Temperature Measurement, Probe Number = 1, T = 20.052000 C 02:44:45 Temperature Measurement, Probe Number = 2, T = 20.027000 C 02:44:45 Temperature Measurement, Probe Number = 3, T = 19.987000 C 02:44:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.99 02:44:45 Integrated Voltage Measurement... 02:45:05 Voltage Offset Correction: v_off_ini = 0.000001880 V, v_off_fin = 0.000006102 V 02:45:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431481 Vs 02:45:05 Integrated Voltage Measurement... 02:45:24 Voltage Offset Correction: v_off_ini = 0.000005185 V, v_off_fin = -0.000001410 V 02:45:25 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175315506 Vs 02:45:27 Temperature Measurement, Probe Number = 0, T = 20.294000 C 02:45:28 Temperature Measurement, Probe Number = 1, T = 20.052000 C 02:45:29 Temperature Measurement, Probe Number = 2, T = 20.025000 C 02:45:29 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:45:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 02:45:29 Integrated Voltage Measurement... 02:45:49 Voltage Offset Correction: v_off_ini = 0.000001850 V, v_off_fin = 0.000005731 V 02:45:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429452 Vs 02:45:49 Integrated Voltage Measurement... 02:46:09 Voltage Offset Correction: v_off_ini = 0.000004776 V, v_off_fin = -0.000001444 V 02:46:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305689 Vs 03:16:11 Temperature Measurement, Probe Number = 0, T = 20.199000 C 03:16:12 Temperature Measurement, Probe Number = 1, T = 20.043000 C 03:16:13 Temperature Measurement, Probe Number = 2, T = 20.012000 C 03:16:14 Temperature Measurement, Probe Number = 3, T = 19.979000 C 03:16:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:16:14 Integrated Voltage Measurement... 03:16:33 Voltage Offset Correction: v_off_ini = 0.000003424 V, v_off_fin = 0.000005483 V 03:16:33 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175515007 Vs 03:16:34 Integrated Voltage Measurement... 03:16:53 Voltage Offset Correction: v_off_ini = 0.000004972 V, v_off_fin = -0.000001834 V 03:16:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303486 Vs 03:16:56 Temperature Measurement, Probe Number = 0, T = 20.188000 C 03:16:56 Temperature Measurement, Probe Number = 1, T = 20.048000 C 03:16:57 Temperature Measurement, Probe Number = 2, T = 20.017000 C 03:16:58 Temperature Measurement, Probe Number = 3, T = 19.984000 C 03:16:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:16:58 Integrated Voltage Measurement... 03:17:17 Voltage Offset Correction: v_off_ini = 0.000001845 V, v_off_fin = 0.000005961 V 03:17:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431050 Vs 03:17:17 Integrated Voltage Measurement... 03:17:37 Voltage Offset Correction: v_off_ini = 0.000005110 V, v_off_fin = -0.000001466 V 03:17:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302708 Vs 03:17:39 Temperature Measurement, Probe Number = 0, T = 20.207000 C 03:17:40 Temperature Measurement, Probe Number = 1, T = 20.049000 C 03:17:41 Temperature Measurement, Probe Number = 2, T = 20.021000 C 03:17:41 Temperature Measurement, Probe Number = 3, T = 19.986000 C 03:17:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 03:17:42 Integrated Voltage Measurement... 03:18:01 Voltage Offset Correction: v_off_ini = 0.000001126 V, v_off_fin = 0.000006197 V 03:18:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429414 Vs 03:18:01 Integrated Voltage Measurement... 03:18:20 Voltage Offset Correction: v_off_ini = 0.000005337 V, v_off_fin = -0.000001694 V 03:18:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310149 Vs 03:18:23 Temperature Measurement, Probe Number = 0, T = 20.153000 C 03:18:24 Temperature Measurement, Probe Number = 1, T = 20.046000 C 03:18:25 Temperature Measurement, Probe Number = 2, T = 20.018000 C 03:18:25 Temperature Measurement, Probe Number = 3, T = 19.981000 C 03:18:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:18:25 Integrated Voltage Measurement... 03:18:44 Voltage Offset Correction: v_off_ini = 0.000001994 V, v_off_fin = 0.000006031 V 03:18:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432587 Vs 03:18:45 Integrated Voltage Measurement... 03:19:04 Voltage Offset Correction: v_off_ini = 0.000005279 V, v_off_fin = -0.000002403 V 03:19:04 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175310047 Vs 03:19:06 Temperature Measurement, Probe Number = 0, T = 20.165000 C 03:19:07 Temperature Measurement, Probe Number = 1, T = 20.044000 C 03:19:08 Temperature Measurement, Probe Number = 2, T = 20.017000 C 03:19:08 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:19:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:19:09 Integrated Voltage Measurement... 03:19:28 Voltage Offset Correction: v_off_ini = 0.000001876 V, v_off_fin = 0.000006340 V 03:19:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438477 Vs 03:19:28 Integrated Voltage Measurement... 03:19:48 Voltage Offset Correction: v_off_ini = 0.000005336 V, v_off_fin = -0.000001242 V 03:19:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307775 Vs 03:19:51 Temperature Measurement, Probe Number = 0, T = 20.181000 C 03:19:51 Temperature Measurement, Probe Number = 1, T = 20.046000 C 03:19:52 Temperature Measurement, Probe Number = 2, T = 20.017000 C 03:19:53 Temperature Measurement, Probe Number = 3, T = 19.986000 C 03:19:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 03:19:53 Integrated Voltage Measurement... 03:20:12 Voltage Offset Correction: v_off_ini = 0.000001724 V, v_off_fin = 0.000006119 V 03:20:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423017 Vs 03:20:12 Integrated Voltage Measurement... 03:20:32 Voltage Offset Correction: v_off_ini = 0.000005331 V, v_off_fin = -0.000001813 V 03:20:32 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175308639 Vs 03:20:35 Temperature Measurement, Probe Number = 0, T = 20.245000 C 03:20:35 Temperature Measurement, Probe Number = 1, T = 20.045000 C 03:20:36 Temperature Measurement, Probe Number = 2, T = 20.016000 C 03:20:37 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:20:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:20:37 Integrated Voltage Measurement... 03:20:56 Voltage Offset Correction: v_off_ini = 0.000001568 V, v_off_fin = 0.000005783 V 03:20:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426910 Vs 03:20:56 Integrated Voltage Measurement... 03:21:16 Voltage Offset Correction: v_off_ini = 0.000005088 V, v_off_fin = -0.000001790 V 03:21:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308464 Vs 03:21:18 Temperature Measurement, Probe Number = 0, T = 20.243000 C 03:21:19 Temperature Measurement, Probe Number = 1, T = 20.048000 C 03:21:20 Temperature Measurement, Probe Number = 2, T = 20.018000 C 03:21:20 Temperature Measurement, Probe Number = 3, T = 19.985000 C 03:21:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:21:21 Integrated Voltage Measurement... 03:21:40 Voltage Offset Correction: v_off_ini = 0.000000849 V, v_off_fin = 0.000006063 V 03:21:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424529 Vs 03:21:40 Integrated Voltage Measurement... 03:21:59 Voltage Offset Correction: v_off_ini = 0.000005294 V, v_off_fin = -0.000001791 V 03:21:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308936 Vs 03:22:02 Temperature Measurement, Probe Number = 0, T = 20.277000 C 03:22:03 Temperature Measurement, Probe Number = 1, T = 20.044000 C 03:22:03 Temperature Measurement, Probe Number = 2, T = 20.012000 C 03:22:04 Temperature Measurement, Probe Number = 3, T = 19.980000 C 03:22:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:22:04 Integrated Voltage Measurement... 03:22:23 Voltage Offset Correction: v_off_ini = 0.000001103 V, v_off_fin = 0.000006695 V 03:22:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435116 Vs 03:22:24 Integrated Voltage Measurement... 03:22:43 Voltage Offset Correction: v_off_ini = 0.000005399 V, v_off_fin = -0.000001719 V 03:22:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307280 Vs 03:22:46 Temperature Measurement, Probe Number = 0, T = 20.244000 C 03:22:46 Temperature Measurement, Probe Number = 1, T = 20.044000 C 03:22:47 Temperature Measurement, Probe Number = 2, T = 20.015000 C 03:22:48 Temperature Measurement, Probe Number = 3, T = 19.981000 C 03:22:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:22:48 Integrated Voltage Measurement... 03:23:07 Voltage Offset Correction: v_off_ini = 0.000001247 V, v_off_fin = 0.000006372 V 03:23:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433228 Vs 03:23:07 Integrated Voltage Measurement... 03:23:27 Voltage Offset Correction: v_off_ini = 0.000005830 V, v_off_fin = -0.000001294 V 03:23:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312335 Vs 03:53:30 Temperature Measurement, Probe Number = 0, T = 20.201000 C 03:53:31 Temperature Measurement, Probe Number = 1, T = 20.041000 C 03:53:31 Temperature Measurement, Probe Number = 2, T = 20.009000 C 03:53:32 Temperature Measurement, Probe Number = 3, T = 19.977000 C 03:53:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:53:32 Integrated Voltage Measurement... 03:53:58 Voltage Offset Correction: v_off_ini = 0.000003689 V, v_off_fin = 0.000003402 V 03:53:58 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175513448 Vs 03:53:58 Integrated Voltage Measurement... 03:54:18 Voltage Offset Correction: v_off_ini = 0.000003870 V, v_off_fin = -0.000002209 V 03:54:18 Integrated Voltage Measurement Delta Gap = -0.0040005 m VT = -0.175304407 Vs 03:54:21 Temperature Measurement, Probe Number = 0, T = 20.191000 C 03:54:21 Temperature Measurement, Probe Number = 1, T = 20.045000 C 03:54:22 Temperature Measurement, Probe Number = 2, T = 20.013000 C 03:54:22 Temperature Measurement, Probe Number = 3, T = 19.982000 C 03:54:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:54:23 Integrated Voltage Measurement... 03:54:42 Voltage Offset Correction: v_off_ini = 0.000001084 V, v_off_fin = 0.000006108 V 03:54:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427445 Vs 03:54:42 Integrated Voltage Measurement... 03:55:01 Voltage Offset Correction: v_off_ini = 0.000005361 V, v_off_fin = -0.000001940 V 03:55:01 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175307582 Vs 03:55:04 Temperature Measurement, Probe Number = 0, T = 20.214000 C 03:55:05 Temperature Measurement, Probe Number = 1, T = 20.044000 C 03:55:05 Temperature Measurement, Probe Number = 2, T = 20.014000 C 03:55:06 Temperature Measurement, Probe Number = 3, T = 19.981000 C 03:55:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:55:06 Integrated Voltage Measurement... 03:55:25 Voltage Offset Correction: v_off_ini = 0.000002056 V, v_off_fin = 0.000005835 V 03:55:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437878 Vs 03:55:25 Integrated Voltage Measurement... 03:55:45 Voltage Offset Correction: v_off_ini = 0.000005054 V, v_off_fin = -0.000002370 V 03:55:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314629 Vs 03:55:48 Temperature Measurement, Probe Number = 0, T = 20.251000 C 03:55:49 Temperature Measurement, Probe Number = 1, T = 20.041000 C 03:55:49 Temperature Measurement, Probe Number = 2, T = 20.013000 C 03:55:50 Temperature Measurement, Probe Number = 3, T = 19.976000 C 03:55:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:55:50 Integrated Voltage Measurement... 03:56:09 Voltage Offset Correction: v_off_ini = 0.000001658 V, v_off_fin = 0.000006206 V 03:56:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428243 Vs 03:56:10 Integrated Voltage Measurement... 03:56:29 Voltage Offset Correction: v_off_ini = 0.000005242 V, v_off_fin = -0.000001246 V 03:56:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308547 Vs 03:56:32 Temperature Measurement, Probe Number = 0, T = 20.244000 C 03:56:32 Temperature Measurement, Probe Number = 1, T = 20.045000 C 03:56:33 Temperature Measurement, Probe Number = 2, T = 20.015000 C 03:56:34 Temperature Measurement, Probe Number = 3, T = 19.981000 C 03:56:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 03:56:34 Integrated Voltage Measurement... 03:56:54 Voltage Offset Correction: v_off_ini = 0.000002075 V, v_off_fin = 0.000005973 V 03:56:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428188 Vs 03:56:54 Integrated Voltage Measurement... 03:57:13 Voltage Offset Correction: v_off_ini = 0.000005252 V, v_off_fin = -0.000001498 V 03:57:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307290 Vs 03:57:16 Temperature Measurement, Probe Number = 0, T = 20.257000 C 03:57:17 Temperature Measurement, Probe Number = 1, T = 20.044000 C 03:57:17 Temperature Measurement, Probe Number = 2, T = 20.014000 C 03:57:18 Temperature Measurement, Probe Number = 3, T = 19.980000 C 03:57:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:57:18 Integrated Voltage Measurement... 03:57:37 Voltage Offset Correction: v_off_ini = 0.000001308 V, v_off_fin = 0.000006287 V 03:57:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428298 Vs 03:57:38 Integrated Voltage Measurement... 03:57:58 Voltage Offset Correction: v_off_ini = 0.000005345 V, v_off_fin = -0.000001561 V 03:57:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311566 Vs 03:58:00 Temperature Measurement, Probe Number = 0, T = 20.169000 C 03:58:01 Temperature Measurement, Probe Number = 1, T = 20.040000 C 03:58:02 Temperature Measurement, Probe Number = 2, T = 20.009000 C 03:58:02 Temperature Measurement, Probe Number = 3, T = 19.974000 C 03:58:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 03:58:03 Integrated Voltage Measurement... 03:58:22 Voltage Offset Correction: v_off_ini = 0.000001790 V, v_off_fin = 0.000006078 V 03:58:22 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175424144 Vs 03:58:23 Integrated Voltage Measurement... 03:58:42 Voltage Offset Correction: v_off_ini = 0.000005112 V, v_off_fin = -0.000002354 V 03:58:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320017 Vs 03:58:45 Temperature Measurement, Probe Number = 0, T = 20.139000 C 03:58:46 Temperature Measurement, Probe Number = 1, T = 20.043000 C 03:58:46 Temperature Measurement, Probe Number = 2, T = 20.011000 C 03:58:47 Temperature Measurement, Probe Number = 3, T = 19.975000 C 03:58:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:58:47 Integrated Voltage Measurement... 03:59:06 Voltage Offset Correction: v_off_ini = 0.000001544 V, v_off_fin = 0.000005775 V 03:59:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425141 Vs 03:59:07 Integrated Voltage Measurement... 03:59:26 Voltage Offset Correction: v_off_ini = 0.000004990 V, v_off_fin = -0.000001896 V 03:59:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318786 Vs 03:59:29 Temperature Measurement, Probe Number = 0, T = 20.156000 C 03:59:30 Temperature Measurement, Probe Number = 1, T = 20.042000 C 03:59:30 Temperature Measurement, Probe Number = 2, T = 20.014000 C 03:59:31 Temperature Measurement, Probe Number = 3, T = 19.978000 C 03:59:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 03:59:31 Integrated Voltage Measurement... 03:59:50 Voltage Offset Correction: v_off_ini = 0.000001719 V, v_off_fin = 0.000006614 V 03:59:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433061 Vs 03:59:51 Integrated Voltage Measurement... 04:00:10 Voltage Offset Correction: v_off_ini = 0.000005931 V, v_off_fin = -0.000002010 V 04:00:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309176 Vs 04:00:13 Temperature Measurement, Probe Number = 0, T = 20.206000 C 04:00:14 Temperature Measurement, Probe Number = 1, T = 20.046000 C 04:00:14 Temperature Measurement, Probe Number = 2, T = 20.017000 C 04:00:15 Temperature Measurement, Probe Number = 3, T = 19.982000 C 04:00:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:00:15 Integrated Voltage Measurement... 04:00:35 Voltage Offset Correction: v_off_ini = 0.000001566 V, v_off_fin = 0.000005851 V 04:00:35 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431351 Vs 04:00:35 Integrated Voltage Measurement... 04:00:54 Voltage Offset Correction: v_off_ini = 0.000005435 V, v_off_fin = -0.000002269 V 04:00:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310192 Vs 04:30:57 Temperature Measurement, Probe Number = 0, T = 20.249000 C 04:30:58 Temperature Measurement, Probe Number = 1, T = 20.042000 C 04:30:59 Temperature Measurement, Probe Number = 2, T = 20.014000 C 04:30:59 Temperature Measurement, Probe Number = 3, T = 19.979000 C 04:30:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 04:31:00 Integrated Voltage Measurement... 04:31:19 Voltage Offset Correction: v_off_ini = 0.000003833 V, v_off_fin = 0.000005776 V 04:31:20 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175524553 Vs 04:31:20 Integrated Voltage Measurement... 04:31:39 Voltage Offset Correction: v_off_ini = 0.000005243 V, v_off_fin = -0.000001459 V 04:31:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312795 Vs 04:31:42 Temperature Measurement, Probe Number = 0, T = 20.265000 C 04:31:43 Temperature Measurement, Probe Number = 1, T = 20.042000 C 04:31:44 Temperature Measurement, Probe Number = 2, T = 20.013000 C 04:31:44 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:31:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 04:31:45 Integrated Voltage Measurement... 04:32:03 Voltage Offset Correction: v_off_ini = 0.000001308 V, v_off_fin = 0.000005759 V 04:32:04 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417484 Vs 04:32:04 Integrated Voltage Measurement... 04:32:23 Voltage Offset Correction: v_off_ini = 0.000004923 V, v_off_fin = -0.000001587 V 04:32:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309787 Vs 04:32:26 Temperature Measurement, Probe Number = 0, T = 20.290000 C 04:32:27 Temperature Measurement, Probe Number = 1, T = 20.043000 C 04:32:27 Temperature Measurement, Probe Number = 2, T = 20.013000 C 04:32:28 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:32:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 04:32:28 Integrated Voltage Measurement... 04:32:47 Voltage Offset Correction: v_off_ini = 0.000001696 V, v_off_fin = 0.000006489 V 04:32:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428029 Vs 04:32:48 Integrated Voltage Measurement... 04:33:07 Voltage Offset Correction: v_off_ini = 0.000005636 V, v_off_fin = -0.000001115 V 04:33:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304811 Vs 04:33:09 Temperature Measurement, Probe Number = 0, T = 20.260000 C 04:33:10 Temperature Measurement, Probe Number = 1, T = 20.042000 C 04:33:11 Temperature Measurement, Probe Number = 2, T = 20.015000 C 04:33:11 Temperature Measurement, Probe Number = 3, T = 19.976000 C 04:33:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:33:12 Integrated Voltage Measurement... 04:33:31 Voltage Offset Correction: v_off_ini = 0.000001624 V, v_off_fin = 0.000006483 V 04:33:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437846 Vs 04:33:31 Integrated Voltage Measurement... 04:33:50 Voltage Offset Correction: v_off_ini = 0.000005764 V, v_off_fin = -0.000001806 V 04:33:51 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175305982 Vs 04:33:53 Temperature Measurement, Probe Number = 0, T = 20.265000 C 04:33:54 Temperature Measurement, Probe Number = 1, T = 20.042000 C 04:33:55 Temperature Measurement, Probe Number = 2, T = 20.015000 C 04:33:55 Temperature Measurement, Probe Number = 3, T = 19.975000 C 04:33:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:33:55 Integrated Voltage Measurement... 04:34:15 Voltage Offset Correction: v_off_ini = 0.000001467 V, v_off_fin = 0.000005813 V 04:34:15 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175437043 Vs 04:34:15 Integrated Voltage Measurement... 04:34:34 Voltage Offset Correction: v_off_ini = 0.000005322 V, v_off_fin = -0.000001821 V 04:34:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313448 Vs 04:34:37 Temperature Measurement, Probe Number = 0, T = 20.272000 C 04:34:38 Temperature Measurement, Probe Number = 1, T = 20.042000 C 04:34:38 Temperature Measurement, Probe Number = 2, T = 20.014000 C 04:34:39 Temperature Measurement, Probe Number = 3, T = 19.977000 C 04:34:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 04:34:39 Integrated Voltage Measurement... 04:34:59 Voltage Offset Correction: v_off_ini = 0.000001317 V, v_off_fin = 0.000005783 V 04:34:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429347 Vs 04:34:59 Integrated Voltage Measurement... 04:35:18 Voltage Offset Correction: v_off_ini = 0.000005169 V, v_off_fin = -0.000001995 V 04:35:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312610 Vs 04:35:22 Temperature Measurement, Probe Number = 0, T = 20.307000 C 04:35:22 Temperature Measurement, Probe Number = 1, T = 20.045000 C 04:35:23 Temperature Measurement, Probe Number = 2, T = 20.013000 C 04:35:23 Temperature Measurement, Probe Number = 3, T = 19.979000 C 04:35:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 04:35:24 Integrated Voltage Measurement... 04:35:43 Voltage Offset Correction: v_off_ini = 0.000001929 V, v_off_fin = 0.000006306 V 04:35:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432861 Vs 04:35:43 Integrated Voltage Measurement... 04:36:02 Voltage Offset Correction: v_off_ini = 0.000005069 V, v_off_fin = -0.000001863 V 04:36:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310016 Vs 04:36:05 Temperature Measurement, Probe Number = 0, T = 20.362000 C 04:36:06 Temperature Measurement, Probe Number = 1, T = 20.043000 C 04:36:07 Temperature Measurement, Probe Number = 2, T = 20.015000 C 04:36:07 Temperature Measurement, Probe Number = 3, T = 19.980000 C 04:36:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:36:08 Integrated Voltage Measurement... 04:36:27 Voltage Offset Correction: v_off_ini = 0.000002084 V, v_off_fin = 0.000006311 V 04:36:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435993 Vs 04:36:27 Integrated Voltage Measurement... 04:36:46 Voltage Offset Correction: v_off_ini = 0.000005241 V, v_off_fin = -0.000002780 V 04:36:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314490 Vs 04:36:49 Temperature Measurement, Probe Number = 0, T = 20.343000 C 04:36:50 Temperature Measurement, Probe Number = 1, T = 20.043000 C 04:36:51 Temperature Measurement, Probe Number = 2, T = 20.015000 C 04:36:51 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:36:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:36:51 Integrated Voltage Measurement... 04:37:11 Voltage Offset Correction: v_off_ini = 0.000001923 V, v_off_fin = 0.000006151 V 04:37:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435349 Vs 04:37:11 Integrated Voltage Measurement... 04:37:30 Voltage Offset Correction: v_off_ini = 0.000004921 V, v_off_fin = -0.000002440 V 04:37:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313951 Vs 04:37:33 Temperature Measurement, Probe Number = 0, T = 20.368000 C 04:37:34 Temperature Measurement, Probe Number = 1, T = 20.044000 C 04:37:34 Temperature Measurement, Probe Number = 2, T = 20.017000 C 04:37:35 Temperature Measurement, Probe Number = 3, T = 19.983000 C 04:37:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 04:37:35 Integrated Voltage Measurement... 04:37:56 Voltage Offset Correction: v_off_ini = 0.000001955 V, v_off_fin = 0.000005246 V 04:37:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434471 Vs 04:37:56 Integrated Voltage Measurement... 04:38:16 Voltage Offset Correction: v_off_ini = 0.000004746 V, v_off_fin = -0.000002267 V 04:38:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313671 Vs 05:08:19 Temperature Measurement, Probe Number = 0, T = 20.238000 C 05:08:20 Temperature Measurement, Probe Number = 1, T = 20.033000 C 05:08:20 Temperature Measurement, Probe Number = 2, T = 20.003000 C 05:08:21 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:08:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:08:21 Integrated Voltage Measurement... 05:08:41 Voltage Offset Correction: v_off_ini = 0.000003716 V, v_off_fin = 0.000005679 V 05:08:41 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175518804 Vs 05:08:41 Integrated Voltage Measurement... 05:09:00 Voltage Offset Correction: v_off_ini = 0.000005124 V, v_off_fin = -0.000002233 V 05:09:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306611 Vs 05:09:03 Temperature Measurement, Probe Number = 0, T = 20.158000 C 05:09:03 Temperature Measurement, Probe Number = 1, T = 20.036000 C 05:09:04 Temperature Measurement, Probe Number = 2, T = 20.004000 C 05:09:05 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:09:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:09:05 Integrated Voltage Measurement... 05:09:24 Voltage Offset Correction: v_off_ini = 0.000001120 V, v_off_fin = 0.000006455 V 05:09:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433191 Vs 05:09:24 Integrated Voltage Measurement... 05:09:44 Voltage Offset Correction: v_off_ini = 0.000005197 V, v_off_fin = -0.000001539 V 05:09:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310059 Vs 05:09:47 Temperature Measurement, Probe Number = 0, T = 20.081000 C 05:09:47 Temperature Measurement, Probe Number = 1, T = 20.037000 C 05:09:48 Temperature Measurement, Probe Number = 2, T = 20.006000 C 05:09:49 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:09:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:09:49 Integrated Voltage Measurement... 05:10:08 Voltage Offset Correction: v_off_ini = 0.000001909 V, v_off_fin = 0.000006353 V 05:10:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427241 Vs 05:10:08 Integrated Voltage Measurement... 05:10:28 Voltage Offset Correction: v_off_ini = 0.000005389 V, v_off_fin = -0.000001701 V 05:10:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311085 Vs 05:10:31 Temperature Measurement, Probe Number = 0, T = 20.155000 C 05:10:31 Temperature Measurement, Probe Number = 1, T = 20.038000 C 05:10:32 Temperature Measurement, Probe Number = 2, T = 20.006000 C 05:10:33 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:10:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:10:33 Integrated Voltage Measurement... 05:10:52 Voltage Offset Correction: v_off_ini = 0.000001622 V, v_off_fin = 0.000006201 V 05:10:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428297 Vs 05:10:52 Integrated Voltage Measurement... 05:11:12 Voltage Offset Correction: v_off_ini = 0.000005278 V, v_off_fin = -0.000001284 V 05:11:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313549 Vs 05:11:15 Temperature Measurement, Probe Number = 0, T = 20.183000 C 05:11:15 Temperature Measurement, Probe Number = 1, T = 20.040000 C 05:11:16 Temperature Measurement, Probe Number = 2, T = 20.011000 C 05:11:17 Temperature Measurement, Probe Number = 3, T = 19.972000 C 05:11:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:11:17 Integrated Voltage Measurement... 05:11:36 Voltage Offset Correction: v_off_ini = 0.000001403 V, v_off_fin = 0.000005878 V 05:11:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434888 Vs 05:11:36 Integrated Voltage Measurement... 05:11:55 Voltage Offset Correction: v_off_ini = 0.000005932 V, v_off_fin = -0.000001520 V 05:11:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306099 Vs 05:11:58 Temperature Measurement, Probe Number = 0, T = 20.250000 C 05:11:59 Temperature Measurement, Probe Number = 1, T = 20.041000 C 05:12:00 Temperature Measurement, Probe Number = 2, T = 20.015000 C 05:12:00 Temperature Measurement, Probe Number = 3, T = 19.976000 C 05:12:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 05:12:00 Integrated Voltage Measurement... 05:12:20 Voltage Offset Correction: v_off_ini = 0.000001785 V, v_off_fin = 0.000006206 V 05:12:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439388 Vs 05:12:20 Integrated Voltage Measurement... 05:12:39 Voltage Offset Correction: v_off_ini = 0.000005954 V, v_off_fin = -0.000001701 V 05:12:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306525 Vs 05:12:42 Temperature Measurement, Probe Number = 0, T = 20.202000 C 05:12:43 Temperature Measurement, Probe Number = 1, T = 20.038000 C 05:12:43 Temperature Measurement, Probe Number = 2, T = 20.014000 C 05:12:44 Temperature Measurement, Probe Number = 3, T = 19.975000 C 05:12:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 05:12:44 Integrated Voltage Measurement... 05:13:03 Voltage Offset Correction: v_off_ini = 0.000001933 V, v_off_fin = 0.000006343 V 05:13:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435147 Vs 05:13:04 Integrated Voltage Measurement... 05:13:23 Voltage Offset Correction: v_off_ini = 0.000006278 V, v_off_fin = -0.000001189 V 05:13:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309368 Vs 05:13:26 Temperature Measurement, Probe Number = 0, T = 20.125000 C 05:13:27 Temperature Measurement, Probe Number = 1, T = 20.038000 C 05:13:27 Temperature Measurement, Probe Number = 2, T = 20.012000 C 05:13:28 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:13:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:13:28 Integrated Voltage Measurement... 05:13:47 Voltage Offset Correction: v_off_ini = 0.000001195 V, v_off_fin = 0.000006132 V 05:13:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430955 Vs 05:13:48 Integrated Voltage Measurement... 05:14:07 Voltage Offset Correction: v_off_ini = 0.000005734 V, v_off_fin = -0.000001877 V 05:14:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317271 Vs 05:14:10 Temperature Measurement, Probe Number = 0, T = 20.183000 C 05:14:11 Temperature Measurement, Probe Number = 1, T = 20.035000 C 05:14:11 Temperature Measurement, Probe Number = 2, T = 20.008000 C 05:14:12 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:14:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:14:12 Integrated Voltage Measurement... 05:14:31 Voltage Offset Correction: v_off_ini = 0.000001841 V, v_off_fin = 0.000006047 V 05:14:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426580 Vs 05:14:32 Integrated Voltage Measurement... 05:14:51 Voltage Offset Correction: v_off_ini = 0.000005270 V, v_off_fin = -0.000001765 V 05:14:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314122 Vs 05:14:54 Temperature Measurement, Probe Number = 0, T = 20.132000 C 05:14:55 Temperature Measurement, Probe Number = 1, T = 20.034000 C 05:14:55 Temperature Measurement, Probe Number = 2, T = 20.008000 C 05:14:56 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:14:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:14:56 Integrated Voltage Measurement... 05:15:15 Voltage Offset Correction: v_off_ini = 0.000001474 V, v_off_fin = 0.000006370 V 05:15:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438025 Vs 05:15:16 Integrated Voltage Measurement... 05:15:35 Voltage Offset Correction: v_off_ini = 0.000005824 V, v_off_fin = -0.000002132 V 05:15:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306644 Vs 05:45:38 Temperature Measurement, Probe Number = 0, T = 20.113000 C 05:45:39 Temperature Measurement, Probe Number = 1, T = 20.034000 C 05:45:40 Temperature Measurement, Probe Number = 2, T = 20.004000 C 05:45:40 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:45:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 05:45:41 Integrated Voltage Measurement... 05:46:00 Voltage Offset Correction: v_off_ini = 0.000003261 V, v_off_fin = 0.000006057 V 05:46:00 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175522354 Vs 05:46:01 Integrated Voltage Measurement... 05:46:20 Voltage Offset Correction: v_off_ini = 0.000005491 V, v_off_fin = -0.000003179 V 05:46:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315748 Vs 05:46:23 Temperature Measurement, Probe Number = 0, T = 20.044000 C 05:46:23 Temperature Measurement, Probe Number = 1, T = 20.033000 C 05:46:24 Temperature Measurement, Probe Number = 2, T = 20.006000 C 05:46:25 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:46:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.04 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:46:25 Integrated Voltage Measurement... 05:46:44 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = 0.000006224 V 05:46:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436982 Vs 05:46:45 Integrated Voltage Measurement... 05:47:04 Voltage Offset Correction: v_off_ini = 0.000005086 V, v_off_fin = -0.000001714 V 05:47:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313533 Vs 05:47:07 Temperature Measurement, Probe Number = 0, T = 20.046000 C 05:47:08 Temperature Measurement, Probe Number = 1, T = 20.034000 C 05:47:08 Temperature Measurement, Probe Number = 2, T = 20.007000 C 05:47:09 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:47:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:47:09 Integrated Voltage Measurement... 05:47:28 Voltage Offset Correction: v_off_ini = 0.000001777 V, v_off_fin = 0.000005539 V 05:47:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430690 Vs 05:47:29 Integrated Voltage Measurement... 05:47:48 Voltage Offset Correction: v_off_ini = 0.000004819 V, v_off_fin = -0.000002046 V 05:47:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320472 Vs 05:47:51 Temperature Measurement, Probe Number = 0, T = 20.017000 C 05:47:52 Temperature Measurement, Probe Number = 1, T = 20.035000 C 05:47:52 Temperature Measurement, Probe Number = 2, T = 20.010000 C 05:47:53 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:47:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.02 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:47:53 Integrated Voltage Measurement... 05:48:12 Voltage Offset Correction: v_off_ini = 0.000002003 V, v_off_fin = 0.000006036 V 05:48:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430641 Vs 05:48:13 Integrated Voltage Measurement... 05:48:32 Voltage Offset Correction: v_off_ini = 0.000005560 V, v_off_fin = -0.000000943 V 05:48:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316822 Vs 05:48:35 Temperature Measurement, Probe Number = 0, T = 20.121000 C 05:48:36 Temperature Measurement, Probe Number = 1, T = 20.036000 C 05:48:36 Temperature Measurement, Probe Number = 2, T = 20.008000 C 05:48:37 Temperature Measurement, Probe Number = 3, T = 19.969000 C 05:48:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:48:37 Integrated Voltage Measurement... 05:48:57 Voltage Offset Correction: v_off_ini = 0.000002184 V, v_off_fin = 0.000005987 V 05:48:57 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432316 Vs 05:48:57 Integrated Voltage Measurement... 05:49:16 Voltage Offset Correction: v_off_ini = 0.000005038 V, v_off_fin = -0.000001979 V 05:49:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320301 Vs 05:49:19 Temperature Measurement, Probe Number = 0, T = 20.210000 C 05:49:20 Temperature Measurement, Probe Number = 1, T = 20.033000 C 05:49:20 Temperature Measurement, Probe Number = 2, T = 20.007000 C 05:49:21 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:49:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:49:21 Integrated Voltage Measurement... 05:49:40 Voltage Offset Correction: v_off_ini = 0.000001547 V, v_off_fin = 0.000006289 V 05:49:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430239 Vs 05:49:41 Integrated Voltage Measurement... 05:50:00 Voltage Offset Correction: v_off_ini = 0.000005764 V, v_off_fin = -0.000001645 V 05:50:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307151 Vs 05:50:03 Temperature Measurement, Probe Number = 0, T = 20.132000 C 05:50:04 Temperature Measurement, Probe Number = 1, T = 20.034000 C 05:50:04 Temperature Measurement, Probe Number = 2, T = 20.009000 C 05:50:05 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:50:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:50:05 Integrated Voltage Measurement... 05:50:25 Voltage Offset Correction: v_off_ini = 0.000001614 V, v_off_fin = 0.000005797 V 05:50:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432838 Vs 05:50:25 Integrated Voltage Measurement... 05:50:44 Voltage Offset Correction: v_off_ini = 0.000005425 V, v_off_fin = -0.000001929 V 05:50:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315524 Vs 05:50:47 Temperature Measurement, Probe Number = 0, T = 20.113000 C 05:50:48 Temperature Measurement, Probe Number = 1, T = 20.035000 C 05:50:49 Temperature Measurement, Probe Number = 2, T = 20.009000 C 05:50:49 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:50:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:50:49 Integrated Voltage Measurement... 05:51:09 Voltage Offset Correction: v_off_ini = 0.000001768 V, v_off_fin = 0.000006215 V 05:51:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431395 Vs 05:51:09 Integrated Voltage Measurement... 05:51:29 Voltage Offset Correction: v_off_ini = 0.000005101 V, v_off_fin = -0.000001471 V 05:51:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313242 Vs 05:51:31 Temperature Measurement, Probe Number = 0, T = 20.148000 C 05:51:32 Temperature Measurement, Probe Number = 1, T = 20.035000 C 05:51:33 Temperature Measurement, Probe Number = 2, T = 20.008000 C 05:51:33 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:51:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:51:34 Integrated Voltage Measurement... 05:51:53 Voltage Offset Correction: v_off_ini = 0.000002045 V, v_off_fin = 0.000005880 V 05:51:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431305 Vs 05:51:53 Integrated Voltage Measurement... 05:52:12 Voltage Offset Correction: v_off_ini = 0.000005142 V, v_off_fin = -0.000002831 V 05:52:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320364 Vs 05:52:15 Temperature Measurement, Probe Number = 0, T = 20.228000 C 05:52:16 Temperature Measurement, Probe Number = 1, T = 20.037000 C 05:52:17 Temperature Measurement, Probe Number = 2, T = 20.011000 C 05:52:17 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:52:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 05:52:17 Integrated Voltage Measurement... 05:52:37 Voltage Offset Correction: v_off_ini = 0.000000566 V, v_off_fin = 0.000005333 V 05:52:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430077 Vs 05:52:37 Integrated Voltage Measurement... 05:52:57 Voltage Offset Correction: v_off_ini = 0.000004544 V, v_off_fin = -0.000002340 V 05:52:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175328345 Vs 06:22:59 Temperature Measurement, Probe Number = 0, T = 20.260000 C 06:23:00 Temperature Measurement, Probe Number = 1, T = 20.028000 C 06:23:01 Temperature Measurement, Probe Number = 2, T = 20.000000 C 06:23:02 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:23:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:23:02 Integrated Voltage Measurement... 06:23:21 Voltage Offset Correction: v_off_ini = 0.000003506 V, v_off_fin = 0.000006220 V 06:23:21 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175530637 Vs 06:23:22 Integrated Voltage Measurement... 06:23:41 Voltage Offset Correction: v_off_ini = 0.000005332 V, v_off_fin = -0.000000697 V 06:23:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305520 Vs 06:23:44 Temperature Measurement, Probe Number = 0, T = 20.183000 C 06:23:44 Temperature Measurement, Probe Number = 1, T = 20.029000 C 06:23:45 Temperature Measurement, Probe Number = 2, T = 20.004000 C 06:23:45 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:23:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:23:46 Integrated Voltage Measurement... 06:24:05 Voltage Offset Correction: v_off_ini = 0.000000203 V, v_off_fin = 0.000006343 V 06:24:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433225 Vs 06:24:05 Integrated Voltage Measurement... 06:24:24 Voltage Offset Correction: v_off_ini = 0.000005361 V, v_off_fin = -0.000001612 V 06:24:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310751 Vs 06:24:27 Temperature Measurement, Probe Number = 0, T = 20.082000 C 06:24:28 Temperature Measurement, Probe Number = 1, T = 20.029000 C 06:24:29 Temperature Measurement, Probe Number = 2, T = 20.005000 C 06:24:29 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:24:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:24:30 Integrated Voltage Measurement... 06:24:49 Voltage Offset Correction: v_off_ini = 0.000002311 V, v_off_fin = 0.000005670 V 06:24:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433847 Vs 06:24:49 Integrated Voltage Measurement... 06:25:09 Voltage Offset Correction: v_off_ini = 0.000005208 V, v_off_fin = -0.000002623 V 06:25:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317965 Vs 06:25:12 Temperature Measurement, Probe Number = 0, T = 20.033000 C 06:25:12 Temperature Measurement, Probe Number = 1, T = 20.025000 C 06:25:13 Temperature Measurement, Probe Number = 2, T = 19.998000 C 06:25:14 Temperature Measurement, Probe Number = 3, T = 19.957000 C 06:25:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:25:14 Integrated Voltage Measurement... 06:25:33 Voltage Offset Correction: v_off_ini = 0.000001132 V, v_off_fin = 0.000005836 V 06:25:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430396 Vs 06:25:33 Integrated Voltage Measurement... 06:25:53 Voltage Offset Correction: v_off_ini = 0.000005168 V, v_off_fin = -0.000001467 V 06:25:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318895 Vs 06:25:56 Temperature Measurement, Probe Number = 0, T = 20.071000 C 06:25:56 Temperature Measurement, Probe Number = 1, T = 20.031000 C 06:25:57 Temperature Measurement, Probe Number = 2, T = 20.002000 C 06:25:58 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:25:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:25:58 Integrated Voltage Measurement... 06:26:17 Voltage Offset Correction: v_off_ini = 0.000001840 V, v_off_fin = 0.000005976 V 06:26:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175426921 Vs 06:26:17 Integrated Voltage Measurement... 06:26:37 Voltage Offset Correction: v_off_ini = 0.000005048 V, v_off_fin = -0.000001938 V 06:26:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317636 Vs 06:26:39 Temperature Measurement, Probe Number = 0, T = 20.122000 C 06:26:40 Temperature Measurement, Probe Number = 1, T = 20.032000 C 06:26:41 Temperature Measurement, Probe Number = 2, T = 20.006000 C 06:26:41 Temperature Measurement, Probe Number = 3, T = 19.967000 C 06:26:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 06:26:42 Integrated Voltage Measurement... 06:27:01 Voltage Offset Correction: v_off_ini = 0.000001356 V, v_off_fin = 0.000005475 V 06:27:01 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431089 Vs 06:27:01 Integrated Voltage Measurement... 06:27:20 Voltage Offset Correction: v_off_ini = 0.000005165 V, v_off_fin = -0.000001796 V 06:27:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317247 Vs 06:27:23 Temperature Measurement, Probe Number = 0, T = 20.191000 C 06:27:24 Temperature Measurement, Probe Number = 1, T = 20.033000 C 06:27:25 Temperature Measurement, Probe Number = 2, T = 20.007000 C 06:27:25 Temperature Measurement, Probe Number = 3, T = 19.970000 C 06:27:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 06:27:25 Integrated Voltage Measurement... 06:27:45 Voltage Offset Correction: v_off_ini = 0.000001419 V, v_off_fin = 0.000006396 V 06:27:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442609 Vs 06:27:45 Integrated Voltage Measurement... 06:28:04 Voltage Offset Correction: v_off_ini = 0.000005301 V, v_off_fin = -0.000001914 V 06:28:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310865 Vs 06:28:07 Temperature Measurement, Probe Number = 0, T = 20.241000 C 06:28:08 Temperature Measurement, Probe Number = 1, T = 20.032000 C 06:28:09 Temperature Measurement, Probe Number = 2, T = 20.010000 C 06:28:09 Temperature Measurement, Probe Number = 3, T = 19.972000 C 06:28:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 06:28:09 Integrated Voltage Measurement... 06:28:29 Voltage Offset Correction: v_off_ini = 0.000001521 V, v_off_fin = 0.000006021 V 06:28:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437998 Vs 06:28:30 Integrated Voltage Measurement... 06:28:49 Voltage Offset Correction: v_off_ini = 0.000005133 V, v_off_fin = -0.000001988 V 06:28:49 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319964 Vs 06:28:52 Temperature Measurement, Probe Number = 0, T = 20.242000 C 06:28:53 Temperature Measurement, Probe Number = 1, T = 20.029000 C 06:28:53 Temperature Measurement, Probe Number = 2, T = 20.006000 C 06:28:54 Temperature Measurement, Probe Number = 3, T = 19.969000 C 06:28:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 06:28:54 Integrated Voltage Measurement... 06:29:14 Voltage Offset Correction: v_off_ini = 0.000001247 V, v_off_fin = 0.000005827 V 06:29:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433245 Vs 06:29:14 Integrated Voltage Measurement... 06:29:33 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = -0.000002914 V 06:29:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315177 Vs 06:29:36 Temperature Measurement, Probe Number = 0, T = 20.127000 C 06:29:37 Temperature Measurement, Probe Number = 1, T = 20.025000 C 06:29:37 Temperature Measurement, Probe Number = 2, T = 19.997000 C 06:29:38 Temperature Measurement, Probe Number = 3, T = 19.961000 C 06:29:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 06:29:38 Integrated Voltage Measurement... 06:29:57 Voltage Offset Correction: v_off_ini = 0.000001471 V, v_off_fin = 0.000005986 V 06:29:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440218 Vs 06:29:58 Integrated Voltage Measurement... 06:30:17 Voltage Offset Correction: v_off_ini = 0.000005196 V, v_off_fin = -0.000001448 V 06:30:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320295 Vs 07:00:20 Temperature Measurement, Probe Number = 0, T = 20.167000 C 07:00:21 Temperature Measurement, Probe Number = 1, T = 20.024000 C 07:00:22 Temperature Measurement, Probe Number = 2, T = 19.999000 C 07:00:22 Temperature Measurement, Probe Number = 3, T = 19.960000 C 07:00:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:00:22 Integrated Voltage Measurement... 07:00:42 Voltage Offset Correction: v_off_ini = 0.000003441 V, v_off_fin = 0.000005476 V 07:00:42 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175524645 Vs 07:00:42 Integrated Voltage Measurement... 07:01:02 Voltage Offset Correction: v_off_ini = 0.000005141 V, v_off_fin = -0.000001364 V 07:01:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175320232 Vs 07:01:05 Temperature Measurement, Probe Number = 0, T = 20.145000 C 07:01:06 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:01:06 Temperature Measurement, Probe Number = 2, T = 19.998000 C 07:01:07 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:01:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:01:07 Integrated Voltage Measurement... 07:01:26 Voltage Offset Correction: v_off_ini = 0.000001010 V, v_off_fin = 0.000005245 V 07:01:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429227 Vs 07:01:26 Integrated Voltage Measurement... 07:01:46 Voltage Offset Correction: v_off_ini = 0.000004944 V, v_off_fin = -0.000001029 V 07:01:46 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313661 Vs 07:01:49 Temperature Measurement, Probe Number = 0, T = 20.172000 C 07:01:50 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:01:50 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:01:51 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:01:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:01:51 Integrated Voltage Measurement... 07:02:10 Voltage Offset Correction: v_off_ini = 0.000001031 V, v_off_fin = 0.000005272 V 07:02:11 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175422657 Vs 07:02:11 Integrated Voltage Measurement... 07:02:30 Voltage Offset Correction: v_off_ini = 0.000004597 V, v_off_fin = -0.000002864 V 07:02:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315711 Vs 07:02:33 Temperature Measurement, Probe Number = 0, T = 20.189000 C 07:02:34 Temperature Measurement, Probe Number = 1, T = 20.032000 C 07:02:34 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:02:35 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:02:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:02:35 Integrated Voltage Measurement... 07:02:54 Voltage Offset Correction: v_off_ini = 0.000001403 V, v_off_fin = 0.000005311 V 07:02:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431502 Vs 07:02:55 Integrated Voltage Measurement... 07:03:14 Voltage Offset Correction: v_off_ini = 0.000004652 V, v_off_fin = -0.000001755 V 07:03:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324227 Vs 07:03:17 Temperature Measurement, Probe Number = 0, T = 20.259000 C 07:03:18 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:03:18 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:03:19 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:03:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 07:03:19 Integrated Voltage Measurement... 07:03:38 Voltage Offset Correction: v_off_ini = 0.000001222 V, v_off_fin = 0.000005603 V 07:03:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175441452 Vs 07:03:38 Integrated Voltage Measurement... 07:03:57 Voltage Offset Correction: v_off_ini = 0.000005026 V, v_off_fin = -0.000003132 V 07:03:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319062 Vs 07:04:00 Temperature Measurement, Probe Number = 0, T = 20.244000 C 07:04:01 Temperature Measurement, Probe Number = 1, T = 20.025000 C 07:04:02 Temperature Measurement, Probe Number = 2, T = 19.998000 C 07:04:02 Temperature Measurement, Probe Number = 3, T = 19.959000 C 07:04:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:04:02 Integrated Voltage Measurement... 07:04:21 Voltage Offset Correction: v_off_ini = 0.000001180 V, v_off_fin = 0.000005847 V 07:04:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441182 Vs 07:04:22 Integrated Voltage Measurement... 07:04:41 Voltage Offset Correction: v_off_ini = 0.000005430 V, v_off_fin = -0.000001899 V 07:04:41 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319988 Vs 07:04:44 Temperature Measurement, Probe Number = 0, T = 20.215000 C 07:04:45 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:04:45 Temperature Measurement, Probe Number = 2, T = 20.004000 C 07:04:46 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:04:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:04:46 Integrated Voltage Measurement... 07:05:05 Voltage Offset Correction: v_off_ini = 0.000001588 V, v_off_fin = 0.000006039 V 07:05:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436763 Vs 07:05:06 Integrated Voltage Measurement... 07:05:25 Voltage Offset Correction: v_off_ini = 0.000006118 V, v_off_fin = -0.000001545 V 07:05:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314390 Vs 07:05:27 Temperature Measurement, Probe Number = 0, T = 20.229000 C 07:05:28 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:05:29 Temperature Measurement, Probe Number = 2, T = 19.999000 C 07:05:29 Temperature Measurement, Probe Number = 3, T = 19.960000 C 07:05:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:05:30 Integrated Voltage Measurement... 07:05:49 Voltage Offset Correction: v_off_ini = 0.000001747 V, v_off_fin = 0.000006029 V 07:05:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446873 Vs 07:05:49 Integrated Voltage Measurement... 07:06:09 Voltage Offset Correction: v_off_ini = 0.000005516 V, v_off_fin = -0.000001496 V 07:06:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313015 Vs 07:06:12 Temperature Measurement, Probe Number = 0, T = 20.217000 C 07:06:12 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:06:13 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:06:13 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:06:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:06:14 Integrated Voltage Measurement... 07:06:34 Voltage Offset Correction: v_off_ini = 0.000001971 V, v_off_fin = 0.000005498 V 07:06:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436603 Vs 07:06:34 Integrated Voltage Measurement... 07:06:53 Voltage Offset Correction: v_off_ini = 0.000005184 V, v_off_fin = -0.000003221 V 07:06:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315795 Vs 07:06:56 Temperature Measurement, Probe Number = 0, T = 20.201000 C 07:06:57 Temperature Measurement, Probe Number = 1, T = 20.030000 C 07:06:58 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:06:58 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:06:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:06:58 Integrated Voltage Measurement... 07:07:18 Voltage Offset Correction: v_off_ini = 0.000001914 V, v_off_fin = 0.000005607 V 07:07:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435680 Vs 07:07:18 Integrated Voltage Measurement... 07:07:37 Voltage Offset Correction: v_off_ini = 0.000004753 V, v_off_fin = -0.000002092 V 07:07:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321139 Vs 07:37:40 Temperature Measurement, Probe Number = 0, T = 20.160000 C 07:37:41 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:37:42 Temperature Measurement, Probe Number = 2, T = 20.001000 C 07:37:42 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:37:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:37:43 Integrated Voltage Measurement... 07:38:02 Voltage Offset Correction: v_off_ini = 0.000003782 V, v_off_fin = 0.000005983 V 07:38:02 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175522852 Vs 07:38:02 Integrated Voltage Measurement... 07:38:21 Voltage Offset Correction: v_off_ini = 0.000005304 V, v_off_fin = -0.000001515 V 07:38:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313038 Vs 07:38:24 Temperature Measurement, Probe Number = 0, T = 20.196000 C 07:38:25 Temperature Measurement, Probe Number = 1, T = 20.030000 C 07:38:26 Temperature Measurement, Probe Number = 2, T = 20.006000 C 07:38:26 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:38:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 07:38:26 Integrated Voltage Measurement... 07:38:46 Voltage Offset Correction: v_off_ini = 0.000001929 V, v_off_fin = 0.000005575 V 07:38:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431901 Vs 07:38:46 Integrated Voltage Measurement... 07:39:05 Voltage Offset Correction: v_off_ini = 0.000005278 V, v_off_fin = -0.000003976 V 07:39:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317523 Vs 07:39:08 Temperature Measurement, Probe Number = 0, T = 20.206000 C 07:39:09 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:39:10 Temperature Measurement, Probe Number = 2, T = 20.000000 C 07:39:10 Temperature Measurement, Probe Number = 3, T = 19.959000 C 07:39:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:39:10 Integrated Voltage Measurement... 07:39:30 Voltage Offset Correction: v_off_ini = 0.000001601 V, v_off_fin = 0.000005790 V 07:39:30 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433267 Vs 07:39:30 Integrated Voltage Measurement... 07:39:49 Voltage Offset Correction: v_off_ini = 0.000005303 V, v_off_fin = -0.000001909 V 07:39:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317345 Vs 07:39:52 Temperature Measurement, Probe Number = 0, T = 20.131000 C 07:39:53 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:39:54 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:39:54 Temperature Measurement, Probe Number = 3, T = 19.959000 C 07:39:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:39:55 Integrated Voltage Measurement... 07:40:14 Voltage Offset Correction: v_off_ini = 0.000001917 V, v_off_fin = 0.000005687 V 07:40:15 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175432026 Vs 07:40:15 Integrated Voltage Measurement... 07:40:34 Voltage Offset Correction: v_off_ini = 0.000005098 V, v_off_fin = -0.000001466 V 07:40:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314463 Vs 07:40:37 Temperature Measurement, Probe Number = 0, T = 20.158000 C 07:40:38 Temperature Measurement, Probe Number = 1, T = 20.025000 C 07:40:38 Temperature Measurement, Probe Number = 2, T = 19.999000 C 07:40:39 Temperature Measurement, Probe Number = 3, T = 19.960000 C 07:40:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:40:39 Integrated Voltage Measurement... 07:40:58 Voltage Offset Correction: v_off_ini = 0.000002453 V, v_off_fin = 0.000006153 V 07:40:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438363 Vs 07:40:59 Integrated Voltage Measurement... 07:41:18 Voltage Offset Correction: v_off_ini = 0.000005442 V, v_off_fin = -0.000001533 V 07:41:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323321 Vs 07:41:21 Temperature Measurement, Probe Number = 0, T = 20.209000 C 07:41:21 Temperature Measurement, Probe Number = 1, T = 20.027000 C 07:41:22 Temperature Measurement, Probe Number = 2, T = 20.000000 C 07:41:23 Temperature Measurement, Probe Number = 3, T = 19.960000 C 07:41:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:41:23 Integrated Voltage Measurement... 07:41:42 Voltage Offset Correction: v_off_ini = 0.000001347 V, v_off_fin = 0.000006048 V 07:41:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438092 Vs 07:41:42 Integrated Voltage Measurement... 07:42:01 Voltage Offset Correction: v_off_ini = 0.000004635 V, v_off_fin = -0.000002226 V 07:42:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319894 Vs 07:42:04 Temperature Measurement, Probe Number = 0, T = 20.243000 C 07:42:05 Temperature Measurement, Probe Number = 1, T = 20.028000 C 07:42:06 Temperature Measurement, Probe Number = 2, T = 20.003000 C 07:42:06 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:42:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:42:06 Integrated Voltage Measurement... 07:42:26 Voltage Offset Correction: v_off_ini = 0.000000943 V, v_off_fin = 0.000005764 V 07:42:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435028 Vs 07:42:26 Integrated Voltage Measurement... 07:42:45 Voltage Offset Correction: v_off_ini = 0.000005127 V, v_off_fin = -0.000001342 V 07:42:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315907 Vs 07:42:48 Temperature Measurement, Probe Number = 0, T = 20.277000 C 07:42:49 Temperature Measurement, Probe Number = 1, T = 20.028000 C 07:42:49 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:42:50 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:42:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:42:50 Integrated Voltage Measurement... 07:43:09 Voltage Offset Correction: v_off_ini = 0.000001293 V, v_off_fin = 0.000005774 V 07:43:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438079 Vs 07:43:10 Integrated Voltage Measurement... 07:43:30 Voltage Offset Correction: v_off_ini = 0.000004967 V, v_off_fin = -0.000000560 V 07:43:30 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175314975 Vs 07:43:32 Temperature Measurement, Probe Number = 0, T = 20.236000 C 07:43:33 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:43:34 Temperature Measurement, Probe Number = 2, T = 20.002000 C 07:43:34 Temperature Measurement, Probe Number = 3, T = 19.961000 C 07:43:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:43:35 Integrated Voltage Measurement... 07:43:54 Voltage Offset Correction: v_off_ini = 0.000002277 V, v_off_fin = 0.000005582 V 07:43:54 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175434873 Vs 07:43:54 Integrated Voltage Measurement... 07:44:14 Voltage Offset Correction: v_off_ini = 0.000005116 V, v_off_fin = -0.000002728 V 07:44:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175327761 Vs 07:44:17 Temperature Measurement, Probe Number = 0, T = 20.269000 C 07:44:18 Temperature Measurement, Probe Number = 1, T = 20.029000 C 07:44:18 Temperature Measurement, Probe Number = 2, T = 20.001000 C 07:44:19 Temperature Measurement, Probe Number = 3, T = 19.960000 C 07:44:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 07:44:19 Integrated Voltage Measurement... 07:44:38 Voltage Offset Correction: v_off_ini = 0.000001139 V, v_off_fin = 0.000006027 V 07:44:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431674 Vs 07:44:39 Integrated Voltage Measurement... 07:44:58 Voltage Offset Correction: v_off_ini = 0.000005325 V, v_off_fin = -0.000002203 V 07:44:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320429 Vs 08:15:01 Temperature Measurement, Probe Number = 0, T = 20.230000 C 08:15:02 Temperature Measurement, Probe Number = 1, T = 20.027000 C 08:15:02 Temperature Measurement, Probe Number = 2, T = 20.000000 C 08:15:03 Temperature Measurement, Probe Number = 3, T = 19.958000 C 08:15:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:15:03 Integrated Voltage Measurement... 08:15:22 Voltage Offset Correction: v_off_ini = 0.000002693 V, v_off_fin = 0.000005522 V 08:15:22 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175523459 Vs 08:15:22 Integrated Voltage Measurement... 08:15:42 Voltage Offset Correction: v_off_ini = 0.000005233 V, v_off_fin = -0.000002350 V 08:15:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316648 Vs 08:15:45 Temperature Measurement, Probe Number = 0, T = 20.140000 C 08:15:45 Temperature Measurement, Probe Number = 1, T = 20.022000 C 08:15:46 Temperature Measurement, Probe Number = 2, T = 19.991000 C 08:15:47 Temperature Measurement, Probe Number = 3, T = 19.953000 C 08:15:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.95 08:15:47 Integrated Voltage Measurement... 08:16:06 Voltage Offset Correction: v_off_ini = 0.000000843 V, v_off_fin = 0.000006586 V 08:16:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436831 Vs 08:16:07 Integrated Voltage Measurement... 08:16:26 Voltage Offset Correction: v_off_ini = 0.000004784 V, v_off_fin = -0.000001721 V 08:16:26 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175315804 Vs 08:16:29 Temperature Measurement, Probe Number = 0, T = 20.117000 C 08:16:30 Temperature Measurement, Probe Number = 1, T = 20.027000 C 08:16:30 Temperature Measurement, Probe Number = 2, T = 20.002000 C 08:16:31 Temperature Measurement, Probe Number = 3, T = 19.956000 C 08:16:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:16:31 Integrated Voltage Measurement... 08:16:50 Voltage Offset Correction: v_off_ini = 0.000001780 V, v_off_fin = 0.000005191 V 08:16:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430935 Vs 08:16:51 Integrated Voltage Measurement... 08:17:10 Voltage Offset Correction: v_off_ini = 0.000005109 V, v_off_fin = -0.000004079 V 08:17:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326261 Vs 08:17:13 Temperature Measurement, Probe Number = 0, T = 20.107000 C 08:17:13 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:17:14 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:17:15 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:17:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:17:15 Integrated Voltage Measurement... 08:17:34 Voltage Offset Correction: v_off_ini = 0.000001132 V, v_off_fin = 0.000006105 V 08:17:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440446 Vs 08:17:35 Integrated Voltage Measurement... 08:17:54 Voltage Offset Correction: v_off_ini = 0.000005448 V, v_off_fin = -0.000002131 V 08:17:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319503 Vs 08:17:57 Temperature Measurement, Probe Number = 0, T = 20.179000 C 08:17:57 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:17:58 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:17:59 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:17:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 08:17:59 Integrated Voltage Measurement... 08:18:18 Voltage Offset Correction: v_off_ini = 0.000001775 V, v_off_fin = 0.000006399 V 08:18:18 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438889 Vs 08:18:19 Integrated Voltage Measurement... 08:18:38 Voltage Offset Correction: v_off_ini = 0.000004934 V, v_off_fin = -0.000002276 V 08:18:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324770 Vs 08:18:41 Temperature Measurement, Probe Number = 0, T = 20.210000 C 08:18:42 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:18:42 Temperature Measurement, Probe Number = 2, T = 20.003000 C 08:18:43 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:18:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 08:18:43 Integrated Voltage Measurement... 08:19:02 Voltage Offset Correction: v_off_ini = 0.000001783 V, v_off_fin = 0.000005803 V 08:19:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437480 Vs 08:19:02 Integrated Voltage Measurement... 08:19:21 Voltage Offset Correction: v_off_ini = 0.000005512 V, v_off_fin = -0.000002521 V 08:19:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317132 Vs 08:19:24 Temperature Measurement, Probe Number = 0, T = 20.208000 C 08:19:25 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:19:26 Temperature Measurement, Probe Number = 2, T = 20.005000 C 08:19:26 Temperature Measurement, Probe Number = 3, T = 19.963000 C 08:19:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:19:26 Integrated Voltage Measurement... 08:19:46 Voltage Offset Correction: v_off_ini = 0.000000745 V, v_off_fin = 0.000004930 V 08:19:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427783 Vs 08:19:46 Integrated Voltage Measurement... 08:20:05 Voltage Offset Correction: v_off_ini = 0.000004419 V, v_off_fin = -0.000002163 V 08:20:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175328631 Vs 08:20:08 Temperature Measurement, Probe Number = 0, T = 20.173000 C 08:20:09 Temperature Measurement, Probe Number = 1, T = 20.028000 C 08:20:10 Temperature Measurement, Probe Number = 2, T = 20.000000 C 08:20:10 Temperature Measurement, Probe Number = 3, T = 19.959000 C 08:20:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:20:10 Integrated Voltage Measurement... 08:20:30 Voltage Offset Correction: v_off_ini = 0.000000910 V, v_off_fin = 0.000005638 V 08:20:30 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428398 Vs 08:20:30 Integrated Voltage Measurement... 08:20:50 Voltage Offset Correction: v_off_ini = 0.000004622 V, v_off_fin = -0.000002453 V 08:20:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175336668 Vs 08:20:52 Temperature Measurement, Probe Number = 0, T = 20.199000 C 08:20:53 Temperature Measurement, Probe Number = 1, T = 20.030000 C 08:20:54 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:20:54 Temperature Measurement, Probe Number = 3, T = 19.960000 C 08:20:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:20:55 Integrated Voltage Measurement... 08:21:14 Voltage Offset Correction: v_off_ini = 0.000000692 V, v_off_fin = 0.000006079 V 08:21:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430037 Vs 08:21:14 Integrated Voltage Measurement... 08:21:33 Voltage Offset Correction: v_off_ini = 0.000005229 V, v_off_fin = -0.000002188 V 08:21:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321429 Vs 08:21:36 Temperature Measurement, Probe Number = 0, T = 20.245000 C 08:21:37 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:21:37 Temperature Measurement, Probe Number = 2, T = 20.007000 C 08:21:38 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:21:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.97 08:21:38 Integrated Voltage Measurement... 08:21:58 Voltage Offset Correction: v_off_ini = 0.000001613 V, v_off_fin = 0.000006105 V 08:21:58 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438478 Vs 08:21:58 Integrated Voltage Measurement... 08:22:17 Voltage Offset Correction: v_off_ini = 0.000005565 V, v_off_fin = -0.000002292 V 08:22:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317926 Vs 08:52:20 Temperature Measurement, Probe Number = 0, T = 20.268000 C 08:52:21 Temperature Measurement, Probe Number = 1, T = 20.029000 C 08:52:22 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:52:22 Temperature Measurement, Probe Number = 3, T = 19.959000 C 08:52:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:52:23 Integrated Voltage Measurement... 08:52:42 Voltage Offset Correction: v_off_ini = 0.000002763 V, v_off_fin = 0.000005214 V 08:52:42 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175520218 Vs 08:52:42 Integrated Voltage Measurement... 08:53:01 Voltage Offset Correction: v_off_ini = 0.000004780 V, v_off_fin = -0.000003029 V 08:53:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325354 Vs 08:53:04 Temperature Measurement, Probe Number = 0, T = 20.155000 C 08:53:05 Temperature Measurement, Probe Number = 1, T = 20.033000 C 08:53:05 Temperature Measurement, Probe Number = 2, T = 20.007000 C 08:53:06 Temperature Measurement, Probe Number = 3, T = 19.963000 C 08:53:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:53:06 Integrated Voltage Measurement... 08:53:25 Voltage Offset Correction: v_off_ini = 0.000001758 V, v_off_fin = 0.000006351 V 08:53:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175446162 Vs 08:53:26 Integrated Voltage Measurement... 08:53:45 Voltage Offset Correction: v_off_ini = 0.000005726 V, v_off_fin = -0.000001377 V 08:53:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314880 Vs 08:53:48 Temperature Measurement, Probe Number = 0, T = 20.186000 C 08:53:49 Temperature Measurement, Probe Number = 1, T = 20.034000 C 08:53:49 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:53:50 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:53:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:53:50 Integrated Voltage Measurement... 08:54:10 Voltage Offset Correction: v_off_ini = 0.000002887 V, v_off_fin = 0.000006252 V 08:54:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447727 Vs 08:54:10 Integrated Voltage Measurement... 08:54:29 Voltage Offset Correction: v_off_ini = 0.000005545 V, v_off_fin = -0.000001951 V 08:54:30 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175324301 Vs 08:54:32 Temperature Measurement, Probe Number = 0, T = 20.237000 C 08:54:33 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:54:34 Temperature Measurement, Probe Number = 2, T = 20.004000 C 08:54:34 Temperature Measurement, Probe Number = 3, T = 19.961000 C 08:54:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:54:35 Integrated Voltage Measurement... 08:54:54 Voltage Offset Correction: v_off_ini = 0.000001066 V, v_off_fin = 0.000006242 V 08:54:54 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439111 Vs 08:54:54 Integrated Voltage Measurement... 08:55:13 Voltage Offset Correction: v_off_ini = 0.000004915 V, v_off_fin = -0.000001577 V 08:55:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318331 Vs 08:55:16 Temperature Measurement, Probe Number = 0, T = 20.241000 C 08:55:17 Temperature Measurement, Probe Number = 1, T = 20.035000 C 08:55:17 Temperature Measurement, Probe Number = 2, T = 20.010000 C 08:55:18 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:55:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:55:18 Integrated Voltage Measurement... 08:55:38 Voltage Offset Correction: v_off_ini = 0.000001433 V, v_off_fin = 0.000005858 V 08:55:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445442 Vs 08:55:38 Integrated Voltage Measurement... 08:55:57 Voltage Offset Correction: v_off_ini = 0.000004688 V, v_off_fin = -0.000001927 V 08:55:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314609 Vs 08:56:00 Temperature Measurement, Probe Number = 0, T = 20.302000 C 08:56:01 Temperature Measurement, Probe Number = 1, T = 20.035000 C 08:56:01 Temperature Measurement, Probe Number = 2, T = 20.006000 C 08:56:02 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:56:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:56:02 Integrated Voltage Measurement... 08:56:21 Voltage Offset Correction: v_off_ini = 0.000002085 V, v_off_fin = 0.000005726 V 08:56:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448140 Vs 08:56:22 Integrated Voltage Measurement... 08:56:41 Voltage Offset Correction: v_off_ini = 0.000004752 V, v_off_fin = -0.000002681 V 08:56:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323748 Vs 08:56:44 Temperature Measurement, Probe Number = 0, T = 20.249000 C 08:56:44 Temperature Measurement, Probe Number = 1, T = 20.032000 C 08:56:45 Temperature Measurement, Probe Number = 2, T = 20.002000 C 08:56:46 Temperature Measurement, Probe Number = 3, T = 19.960000 C 08:56:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:56:46 Integrated Voltage Measurement... 08:57:05 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000005592 V 08:57:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441215 Vs 08:57:05 Integrated Voltage Measurement... 08:57:24 Voltage Offset Correction: v_off_ini = 0.000006051 V, v_off_fin = -0.000003367 V 08:57:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318961 Vs 08:57:27 Temperature Measurement, Probe Number = 0, T = 20.260000 C 08:57:28 Temperature Measurement, Probe Number = 1, T = 20.033000 C 08:57:28 Temperature Measurement, Probe Number = 2, T = 20.005000 C 08:57:29 Temperature Measurement, Probe Number = 3, T = 19.956000 C 08:57:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 08:57:29 Integrated Voltage Measurement... 08:57:48 Voltage Offset Correction: v_off_ini = 0.000001221 V, v_off_fin = 0.000005485 V 08:57:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441042 Vs 08:57:49 Integrated Voltage Measurement... 08:58:08 Voltage Offset Correction: v_off_ini = 0.000005614 V, v_off_fin = -0.000001313 V 08:58:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324102 Vs 08:58:11 Temperature Measurement, Probe Number = 0, T = 20.278000 C 08:58:12 Temperature Measurement, Probe Number = 1, T = 20.035000 C 08:58:12 Temperature Measurement, Probe Number = 2, T = 20.009000 C 08:58:13 Temperature Measurement, Probe Number = 3, T = 19.962000 C 08:58:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:58:13 Integrated Voltage Measurement... 08:58:32 Voltage Offset Correction: v_off_ini = 0.000001874 V, v_off_fin = 0.000006797 V 08:58:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444443 Vs 08:58:32 Integrated Voltage Measurement... 08:58:52 Voltage Offset Correction: v_off_ini = 0.000006318 V, v_off_fin = -0.000001787 V 08:58:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314608 Vs 08:58:55 Temperature Measurement, Probe Number = 0, T = 20.319000 C 08:58:55 Temperature Measurement, Probe Number = 1, T = 20.035000 C 08:58:56 Temperature Measurement, Probe Number = 2, T = 20.008000 C 08:58:57 Temperature Measurement, Probe Number = 3, T = 19.964000 C 08:58:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 08:58:57 Integrated Voltage Measurement... 08:59:16 Voltage Offset Correction: v_off_ini = 0.000001952 V, v_off_fin = 0.000006023 V 08:59:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440251 Vs 08:59:16 Integrated Voltage Measurement... 08:59:35 Voltage Offset Correction: v_off_ini = 0.000005666 V, v_off_fin = -0.000002940 V 08:59:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318669 Vs 09:29:38 Temperature Measurement, Probe Number = 0, T = 20.329000 C 09:29:39 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:29:39 Temperature Measurement, Probe Number = 2, T = 20.002000 C 09:29:40 Temperature Measurement, Probe Number = 3, T = 19.955000 C 09:29:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.95 09:29:40 Integrated Voltage Measurement... 09:30:00 Voltage Offset Correction: v_off_ini = 0.000003383 V, v_off_fin = 0.000005611 V 09:30:00 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175533591 Vs 09:30:00 Integrated Voltage Measurement... 09:30:20 Voltage Offset Correction: v_off_ini = 0.000004751 V, v_off_fin = -0.000002250 V 09:30:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325295 Vs 09:30:22 Temperature Measurement, Probe Number = 0, T = 20.311000 C 09:30:23 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:30:24 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:30:24 Temperature Measurement, Probe Number = 3, T = 19.957000 C 09:30:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 09:30:25 Integrated Voltage Measurement... 09:30:44 Voltage Offset Correction: v_off_ini = 0.000001069 V, v_off_fin = 0.000006082 V 09:30:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439190 Vs 09:30:44 Integrated Voltage Measurement... 09:31:04 Voltage Offset Correction: v_off_ini = 0.000005002 V, v_off_fin = -0.000001184 V 09:31:04 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175316174 Vs 09:31:07 Temperature Measurement, Probe Number = 0, T = 20.338000 C 09:31:07 Temperature Measurement, Probe Number = 1, T = 20.034000 C 09:31:08 Temperature Measurement, Probe Number = 2, T = 20.006000 C 09:31:09 Temperature Measurement, Probe Number = 3, T = 19.960000 C 09:31:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 09:31:09 Integrated Voltage Measurement... 09:31:28 Voltage Offset Correction: v_off_ini = 0.000001083 V, v_off_fin = 0.000005647 V 09:31:28 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175430148 Vs 09:31:28 Integrated Voltage Measurement... 09:31:48 Voltage Offset Correction: v_off_ini = 0.000004827 V, v_off_fin = -0.000002516 V 09:31:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320923 Vs 09:31:51 Temperature Measurement, Probe Number = 0, T = 20.356000 C 09:31:51 Temperature Measurement, Probe Number = 1, T = 20.036000 C 09:31:52 Temperature Measurement, Probe Number = 2, T = 20.007000 C 09:31:52 Temperature Measurement, Probe Number = 3, T = 19.964000 C 09:31:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 09:31:53 Integrated Voltage Measurement... 09:32:12 Voltage Offset Correction: v_off_ini = 0.000001165 V, v_off_fin = 0.000005970 V 09:32:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439032 Vs 09:32:12 Integrated Voltage Measurement... 09:32:32 Voltage Offset Correction: v_off_ini = 0.000005152 V, v_off_fin = -0.000001425 V 09:32:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324005 Vs 09:32:35 Temperature Measurement, Probe Number = 0, T = 20.337000 C 09:32:35 Temperature Measurement, Probe Number = 1, T = 20.033000 C 09:32:36 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:32:37 Temperature Measurement, Probe Number = 3, T = 19.962000 C 09:32:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 09:32:37 Integrated Voltage Measurement... 09:32:56 Voltage Offset Correction: v_off_ini = 0.000002041 V, v_off_fin = 0.000006019 V 09:32:56 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175443289 Vs 09:32:56 Integrated Voltage Measurement... 09:33:16 Voltage Offset Correction: v_off_ini = 0.000005424 V, v_off_fin = -0.000002076 V 09:33:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175321478 Vs 09:33:19 Temperature Measurement, Probe Number = 0, T = 20.298000 C 09:33:20 Temperature Measurement, Probe Number = 1, T = 20.034000 C 09:33:20 Temperature Measurement, Probe Number = 2, T = 20.007000 C 09:33:21 Temperature Measurement, Probe Number = 3, T = 19.960000 C 09:33:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 09:33:21 Integrated Voltage Measurement... 09:33:40 Voltage Offset Correction: v_off_ini = 0.000002230 V, v_off_fin = 0.000006155 V 09:33:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438354 Vs 09:33:41 Integrated Voltage Measurement... 09:34:00 Voltage Offset Correction: v_off_ini = 0.000005294 V, v_off_fin = -0.000001324 V 09:34:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322636 Vs 09:34:03 Temperature Measurement, Probe Number = 0, T = 20.277000 C 09:34:04 Temperature Measurement, Probe Number = 1, T = 20.032000 C 09:34:04 Temperature Measurement, Probe Number = 2, T = 20.004000 C 09:34:05 Temperature Measurement, Probe Number = 3, T = 19.959000 C 09:34:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 09:34:05 Integrated Voltage Measurement... 09:34:24 Voltage Offset Correction: v_off_ini = 0.000002466 V, v_off_fin = 0.000006025 V 09:34:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175439055 Vs 09:34:25 Integrated Voltage Measurement... 09:34:44 Voltage Offset Correction: v_off_ini = 0.000005249 V, v_off_fin = -0.000001418 V 09:34:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314545 Vs 09:34:47 Temperature Measurement, Probe Number = 0, T = 20.323000 C 09:34:48 Temperature Measurement, Probe Number = 1, T = 20.033000 C 09:34:48 Temperature Measurement, Probe Number = 2, T = 20.007000 C 09:34:49 Temperature Measurement, Probe Number = 3, T = 19.960000 C 09:34:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 09:34:49 Integrated Voltage Measurement... 09:35:08 Voltage Offset Correction: v_off_ini = 0.000001679 V, v_off_fin = 0.000005554 V 09:35:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440546 Vs 09:35:09 Integrated Voltage Measurement... 09:35:28 Voltage Offset Correction: v_off_ini = 0.000005217 V, v_off_fin = -0.000001926 V 09:35:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315436 Vs 09:35:31 Temperature Measurement, Probe Number = 0, T = 20.308000 C 09:35:32 Temperature Measurement, Probe Number = 1, T = 20.030000 C 09:35:32 Temperature Measurement, Probe Number = 2, T = 20.007000 C 09:35:33 Temperature Measurement, Probe Number = 3, T = 19.962000 C 09:35:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 09:35:33 Integrated Voltage Measurement... 09:35:52 Voltage Offset Correction: v_off_ini = 0.000002010 V, v_off_fin = 0.000005501 V 09:35:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445791 Vs 09:35:53 Integrated Voltage Measurement... 09:36:12 Voltage Offset Correction: v_off_ini = 0.000004908 V, v_off_fin = -0.000002652 V 09:36:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323713 Vs 09:36:15 Temperature Measurement, Probe Number = 0, T = 20.214000 C 09:36:16 Temperature Measurement, Probe Number = 1, T = 20.029000 C 09:36:16 Temperature Measurement, Probe Number = 2, T = 20.003000 C 09:36:17 Temperature Measurement, Probe Number = 3, T = 19.959000 C 09:36:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.96 09:36:17 Integrated Voltage Measurement... 09:36:36 Voltage Offset Correction: v_off_ini = 0.000001231 V, v_off_fin = 0.000005889 V 09:36:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444840 Vs 09:36:37 Integrated Voltage Measurement... 09:36:56 Voltage Offset Correction: v_off_ini = 0.000005209 V, v_off_fin = -0.000002251 V 09:36:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175326989 Vs 10:06:59 Temperature Measurement, Probe Number = 0, T = 20.275000 C 10:07:00 Temperature Measurement, Probe Number = 1, T = 20.032000 C 10:07:00 Temperature Measurement, Probe Number = 2, T = 20.008000 C 10:07:01 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:07:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:07:01 Integrated Voltage Measurement... 10:07:20 Voltage Offset Correction: v_off_ini = 0.000003252 V, v_off_fin = 0.000005459 V 10:07:21 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175530268 Vs 10:07:21 Integrated Voltage Measurement... 10:07:40 Voltage Offset Correction: v_off_ini = 0.000005044 V, v_off_fin = -0.000002222 V 10:07:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313314 Vs 10:07:43 Temperature Measurement, Probe Number = 0, T = 20.313000 C 10:07:43 Temperature Measurement, Probe Number = 1, T = 20.033000 C 10:07:44 Temperature Measurement, Probe Number = 2, T = 20.008000 C 10:07:45 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:07:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:07:45 Integrated Voltage Measurement... 10:08:04 Voltage Offset Correction: v_off_ini = 0.000001627 V, v_off_fin = 0.000006167 V 10:08:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439656 Vs 10:08:05 Integrated Voltage Measurement... 10:08:24 Voltage Offset Correction: v_off_ini = 0.000005314 V, v_off_fin = -0.000001679 V 10:08:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317188 Vs 10:08:27 Temperature Measurement, Probe Number = 0, T = 20.333000 C 10:08:28 Temperature Measurement, Probe Number = 1, T = 20.035000 C 10:08:28 Temperature Measurement, Probe Number = 2, T = 20.012000 C 10:08:29 Temperature Measurement, Probe Number = 3, T = 19.961000 C 10:08:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:08:29 Integrated Voltage Measurement... 10:08:49 Voltage Offset Correction: v_off_ini = 0.000000521 V, v_off_fin = 0.000006211 V 10:08:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430169 Vs 10:08:49 Integrated Voltage Measurement... 10:09:08 Voltage Offset Correction: v_off_ini = 0.000004957 V, v_off_fin = -0.000002486 V 10:09:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308139 Vs 10:09:11 Temperature Measurement, Probe Number = 0, T = 20.387000 C 10:09:12 Temperature Measurement, Probe Number = 1, T = 20.038000 C 10:09:12 Temperature Measurement, Probe Number = 2, T = 20.015000 C 10:09:13 Temperature Measurement, Probe Number = 3, T = 19.964000 C 10:09:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.96 10:09:13 Integrated Voltage Measurement... 10:09:32 Voltage Offset Correction: v_off_ini = 0.000001781 V, v_off_fin = 0.000006667 V 10:09:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435664 Vs 10:09:33 Integrated Voltage Measurement... 10:09:52 Voltage Offset Correction: v_off_ini = 0.000005533 V, v_off_fin = -0.000001825 V 10:09:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175304082 Vs 10:09:54 Temperature Measurement, Probe Number = 0, T = 20.405000 C 10:09:55 Temperature Measurement, Probe Number = 1, T = 20.038000 C 10:09:56 Temperature Measurement, Probe Number = 2, T = 20.015000 C 10:09:56 Temperature Measurement, Probe Number = 3, T = 19.965000 C 10:09:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.96 10:09:57 Integrated Voltage Measurement... 10:10:16 Voltage Offset Correction: v_off_ini = 0.000002344 V, v_off_fin = 0.000006625 V 10:10:16 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175442758 Vs 10:10:16 Integrated Voltage Measurement... 10:10:35 Voltage Offset Correction: v_off_ini = 0.000005318 V, v_off_fin = -0.000002256 V 10:10:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308741 Vs 10:10:38 Temperature Measurement, Probe Number = 0, T = 20.381000 C 10:10:39 Temperature Measurement, Probe Number = 1, T = 20.039000 C 10:10:40 Temperature Measurement, Probe Number = 2, T = 20.015000 C 10:10:40 Temperature Measurement, Probe Number = 3, T = 19.963000 C 10:10:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.96 10:10:40 Integrated Voltage Measurement... 10:11:00 Voltage Offset Correction: v_off_ini = 0.000001674 V, v_off_fin = 0.000006002 V 10:11:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440353 Vs 10:11:00 Integrated Voltage Measurement... 10:11:19 Voltage Offset Correction: v_off_ini = 0.000005423 V, v_off_fin = -0.000001989 V 10:11:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316941 Vs 10:11:22 Temperature Measurement, Probe Number = 0, T = 20.379000 C 10:11:23 Temperature Measurement, Probe Number = 1, T = 20.038000 C 10:11:24 Temperature Measurement, Probe Number = 2, T = 20.013000 C 10:11:24 Temperature Measurement, Probe Number = 3, T = 19.965000 C 10:11:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:11:24 Integrated Voltage Measurement... 10:11:44 Voltage Offset Correction: v_off_ini = 0.000001861 V, v_off_fin = 0.000005778 V 10:11:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438585 Vs 10:11:44 Integrated Voltage Measurement... 10:12:04 Voltage Offset Correction: v_off_ini = 0.000005142 V, v_off_fin = -0.000002278 V 10:12:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323217 Vs 10:12:07 Temperature Measurement, Probe Number = 0, T = 20.380000 C 10:12:07 Temperature Measurement, Probe Number = 1, T = 20.038000 C 10:12:08 Temperature Measurement, Probe Number = 2, T = 20.012000 C 10:12:09 Temperature Measurement, Probe Number = 3, T = 19.963000 C 10:12:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:12:09 Integrated Voltage Measurement... 10:12:29 Voltage Offset Correction: v_off_ini = 0.000001487 V, v_off_fin = 0.000005145 V 10:12:29 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423055 Vs 10:12:29 Integrated Voltage Measurement... 10:12:49 Voltage Offset Correction: v_off_ini = 0.000004632 V, v_off_fin = -0.000001315 V 10:12:49 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175314039 Vs 10:12:52 Temperature Measurement, Probe Number = 0, T = 20.411000 C 10:12:52 Temperature Measurement, Probe Number = 1, T = 20.035000 C 10:12:53 Temperature Measurement, Probe Number = 2, T = 20.010000 C 10:12:54 Temperature Measurement, Probe Number = 3, T = 19.964000 C 10:12:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:12:54 Integrated Voltage Measurement... 10:13:13 Voltage Offset Correction: v_off_ini = 0.000002063 V, v_off_fin = 0.000006148 V 10:13:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424836 Vs 10:13:13 Integrated Voltage Measurement... 10:13:32 Voltage Offset Correction: v_off_ini = 0.000005819 V, v_off_fin = -0.000002059 V 10:13:33 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175320780 Vs 10:13:35 Temperature Measurement, Probe Number = 0, T = 20.384000 C 10:13:36 Temperature Measurement, Probe Number = 1, T = 20.036000 C 10:13:37 Temperature Measurement, Probe Number = 2, T = 20.012000 C 10:13:37 Temperature Measurement, Probe Number = 3, T = 19.963000 C 10:13:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.96 10:13:38 Integrated Voltage Measurement... 10:13:57 Voltage Offset Correction: v_off_ini = 0.000001391 V, v_off_fin = 0.000005916 V 10:13:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432054 Vs 10:13:57 Integrated Voltage Measurement... 10:14:16 Voltage Offset Correction: v_off_ini = 0.000005061 V, v_off_fin = -0.000002134 V 10:14:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308701 Vs 10:44:19 Temperature Measurement, Probe Number = 0, T = 20.456000 C 10:44:20 Temperature Measurement, Probe Number = 1, T = 20.044000 C 10:44:20 Temperature Measurement, Probe Number = 2, T = 20.023000 C 10:44:21 Temperature Measurement, Probe Number = 3, T = 19.972000 C 10:44:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:44:21 Integrated Voltage Measurement... 10:44:40 Voltage Offset Correction: v_off_ini = 0.000003010 V, v_off_fin = 0.000005469 V 10:44:41 Integrated Voltage Measurement Delta Gap = 0.0040038 m VT = 0.175529869 Vs 10:44:41 Integrated Voltage Measurement... 10:45:00 Voltage Offset Correction: v_off_ini = 0.000004457 V, v_off_fin = -0.000001000 V 10:45:00 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175299472 Vs 10:45:03 Temperature Measurement, Probe Number = 0, T = 20.452000 C 10:45:03 Temperature Measurement, Probe Number = 1, T = 20.045000 C 10:45:04 Temperature Measurement, Probe Number = 2, T = 20.026000 C 10:45:05 Temperature Measurement, Probe Number = 3, T = 19.973000 C 10:45:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.97 10:45:05 Integrated Voltage Measurement... 10:45:24 Voltage Offset Correction: v_off_ini = -0.000000157 V, v_off_fin = 0.000004830 V 10:45:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409950 Vs 10:45:24 Integrated Voltage Measurement... 10:45:44 Voltage Offset Correction: v_off_ini = 0.000004153 V, v_off_fin = -0.000003062 V 10:45:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311493 Vs 10:45:47 Temperature Measurement, Probe Number = 0, T = 20.407000 C 10:45:48 Temperature Measurement, Probe Number = 1, T = 20.044000 C 10:45:48 Temperature Measurement, Probe Number = 2, T = 20.024000 C 10:45:49 Temperature Measurement, Probe Number = 3, T = 19.972000 C 10:45:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:45:49 Integrated Voltage Measurement... 10:46:08 Voltage Offset Correction: v_off_ini = 0.000000741 V, v_off_fin = 0.000005385 V 10:46:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175403593 Vs 10:46:09 Integrated Voltage Measurement... 10:46:29 Voltage Offset Correction: v_off_ini = 0.000004745 V, v_off_fin = -0.000002085 V 10:46:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308496 Vs 10:46:31 Temperature Measurement, Probe Number = 0, T = 20.430000 C 10:46:32 Temperature Measurement, Probe Number = 1, T = 20.043000 C 10:46:33 Temperature Measurement, Probe Number = 2, T = 20.024000 C 10:46:33 Temperature Measurement, Probe Number = 3, T = 19.970000 C 10:46:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:46:34 Integrated Voltage Measurement... 10:46:53 Voltage Offset Correction: v_off_ini = 0.000001259 V, v_off_fin = 0.000005149 V 10:46:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175401491 Vs 10:46:53 Integrated Voltage Measurement... 10:47:12 Voltage Offset Correction: v_off_ini = 0.000004846 V, v_off_fin = -0.000003202 V 10:47:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304088 Vs 10:47:15 Temperature Measurement, Probe Number = 0, T = 20.388000 C 10:47:16 Temperature Measurement, Probe Number = 1, T = 20.046000 C 10:47:16 Temperature Measurement, Probe Number = 2, T = 20.025000 C 10:47:17 Temperature Measurement, Probe Number = 3, T = 19.974000 C 10:47:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:47:17 Integrated Voltage Measurement... 10:47:36 Voltage Offset Correction: v_off_ini = 0.000000966 V, v_off_fin = 0.000005195 V 10:47:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412054 Vs 10:47:36 Integrated Voltage Measurement... 10:47:56 Voltage Offset Correction: v_off_ini = 0.000004493 V, v_off_fin = -0.000003940 V 10:47:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310270 Vs 10:47:59 Temperature Measurement, Probe Number = 0, T = 20.447000 C 10:47:59 Temperature Measurement, Probe Number = 1, T = 20.047000 C 10:48:00 Temperature Measurement, Probe Number = 2, T = 20.023000 C 10:48:01 Temperature Measurement, Probe Number = 3, T = 19.972000 C 10:48:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:48:01 Integrated Voltage Measurement... 10:48:20 Voltage Offset Correction: v_off_ini = 0.000000575 V, v_off_fin = 0.000004812 V 10:48:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408985 Vs 10:48:20 Integrated Voltage Measurement... 10:48:39 Voltage Offset Correction: v_off_ini = 0.000004287 V, v_off_fin = -0.000003158 V 10:48:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306513 Vs 10:48:42 Temperature Measurement, Probe Number = 0, T = 20.410000 C 10:48:43 Temperature Measurement, Probe Number = 1, T = 20.039000 C 10:48:44 Temperature Measurement, Probe Number = 2, T = 20.021000 C 10:48:44 Temperature Measurement, Probe Number = 3, T = 19.969000 C 10:48:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:48:44 Integrated Voltage Measurement... 10:49:03 Voltage Offset Correction: v_off_ini = 0.000001288 V, v_off_fin = 0.000005667 V 10:49:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413728 Vs 10:49:04 Integrated Voltage Measurement... 10:49:23 Voltage Offset Correction: v_off_ini = 0.000004684 V, v_off_fin = -0.000002606 V 10:49:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299845 Vs 10:49:26 Temperature Measurement, Probe Number = 0, T = 20.439000 C 10:49:27 Temperature Measurement, Probe Number = 1, T = 20.041000 C 10:49:27 Temperature Measurement, Probe Number = 2, T = 20.022000 C 10:49:28 Temperature Measurement, Probe Number = 3, T = 19.969000 C 10:49:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:49:28 Integrated Voltage Measurement... 10:49:47 Voltage Offset Correction: v_off_ini = 0.000000433 V, v_off_fin = 0.000005003 V 10:49:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409473 Vs 10:49:48 Integrated Voltage Measurement... 10:50:09 Voltage Offset Correction: v_off_ini = 0.000004975 V, v_off_fin = -0.000000988 V 10:50:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313103 Vs 10:50:11 Temperature Measurement, Probe Number = 0, T = 20.399000 C 10:50:12 Temperature Measurement, Probe Number = 1, T = 20.041000 C 10:50:13 Temperature Measurement, Probe Number = 2, T = 20.021000 C 10:50:13 Temperature Measurement, Probe Number = 3, T = 19.971000 C 10:50:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:50:14 Integrated Voltage Measurement... 10:50:33 Voltage Offset Correction: v_off_ini = 0.000001683 V, v_off_fin = 0.000004577 V 10:50:33 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175394445 Vs 10:50:33 Integrated Voltage Measurement... 10:50:52 Voltage Offset Correction: v_off_ini = 0.000003673 V, v_off_fin = -0.000003563 V 10:50:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315095 Vs 10:50:55 Temperature Measurement, Probe Number = 0, T = 20.381000 C 10:50:56 Temperature Measurement, Probe Number = 1, T = 20.040000 C 10:50:57 Temperature Measurement, Probe Number = 2, T = 20.019000 C 10:50:57 Temperature Measurement, Probe Number = 3, T = 19.969000 C 10:50:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 10:50:58 Integrated Voltage Measurement... 10:51:17 Voltage Offset Correction: v_off_ini = -0.000000014 V, v_off_fin = 0.000004800 V 10:51:17 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417711 Vs 10:51:17 Integrated Voltage Measurement... 10:51:36 Voltage Offset Correction: v_off_ini = 0.000003946 V, v_off_fin = -0.000002881 V 10:51:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307417 Vs 11:21:39 Temperature Measurement, Probe Number = 0, T = 20.165000 C 11:21:40 Temperature Measurement, Probe Number = 1, T = 20.048000 C 11:21:41 Temperature Measurement, Probe Number = 2, T = 20.025000 C 11:21:41 Temperature Measurement, Probe Number = 3, T = 19.976000 C 11:21:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:21:41 Integrated Voltage Measurement... 11:22:01 Voltage Offset Correction: v_off_ini = 0.000004183 V, v_off_fin = 0.000005533 V 11:22:01 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175516066 Vs 11:22:01 Integrated Voltage Measurement... 11:22:20 Voltage Offset Correction: v_off_ini = 0.000004924 V, v_off_fin = -0.000002924 V 11:22:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302635 Vs 11:22:23 Temperature Measurement, Probe Number = 0, T = 20.169000 C 11:22:24 Temperature Measurement, Probe Number = 1, T = 20.049000 C 11:22:24 Temperature Measurement, Probe Number = 2, T = 20.024000 C 11:22:25 Temperature Measurement, Probe Number = 3, T = 19.977000 C 11:22:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:22:25 Integrated Voltage Measurement... 11:22:44 Voltage Offset Correction: v_off_ini = 0.000001413 V, v_off_fin = 0.000005553 V 11:22:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419163 Vs 11:22:45 Integrated Voltage Measurement... 11:23:04 Voltage Offset Correction: v_off_ini = 0.000005473 V, v_off_fin = -0.000001524 V 11:23:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306346 Vs 11:23:07 Temperature Measurement, Probe Number = 0, T = 20.242000 C 11:23:07 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:23:08 Temperature Measurement, Probe Number = 2, T = 20.017000 C 11:23:09 Temperature Measurement, Probe Number = 3, T = 19.970000 C 11:23:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:23:09 Integrated Voltage Measurement... 11:23:28 Voltage Offset Correction: v_off_ini = 0.000001370 V, v_off_fin = 0.000005832 V 11:23:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421876 Vs 11:23:28 Integrated Voltage Measurement... 11:23:47 Voltage Offset Correction: v_off_ini = 0.000005358 V, v_off_fin = -0.000003470 V 11:23:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300923 Vs 11:23:50 Temperature Measurement, Probe Number = 0, T = 20.135000 C 11:23:51 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:23:52 Temperature Measurement, Probe Number = 2, T = 20.020000 C 11:23:52 Temperature Measurement, Probe Number = 3, T = 19.968000 C 11:23:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:23:52 Integrated Voltage Measurement... 11:24:12 Voltage Offset Correction: v_off_ini = 0.000001161 V, v_off_fin = 0.000006057 V 11:24:12 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175419831 Vs 11:24:12 Integrated Voltage Measurement... 11:24:31 Voltage Offset Correction: v_off_ini = 0.000004847 V, v_off_fin = -0.000002440 V 11:24:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301573 Vs 11:24:34 Temperature Measurement, Probe Number = 0, T = 20.076000 C 11:24:35 Temperature Measurement, Probe Number = 1, T = 20.044000 C 11:24:35 Temperature Measurement, Probe Number = 2, T = 20.020000 C 11:24:36 Temperature Measurement, Probe Number = 3, T = 19.970000 C 11:24:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:24:36 Integrated Voltage Measurement... 11:24:56 Voltage Offset Correction: v_off_ini = 0.000001115 V, v_off_fin = 0.000005356 V 11:24:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425446 Vs 11:24:56 Integrated Voltage Measurement... 11:25:15 Voltage Offset Correction: v_off_ini = 0.000004998 V, v_off_fin = -0.000002357 V 11:25:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307970 Vs 11:25:18 Temperature Measurement, Probe Number = 0, T = 20.086000 C 11:25:19 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:25:20 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:25:20 Temperature Measurement, Probe Number = 3, T = 19.967000 C 11:25:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:25:20 Integrated Voltage Measurement... 11:25:40 Voltage Offset Correction: v_off_ini = 0.000001102 V, v_off_fin = 0.000005428 V 11:25:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413471 Vs 11:25:40 Integrated Voltage Measurement... 11:25:59 Voltage Offset Correction: v_off_ini = 0.000004776 V, v_off_fin = -0.000002257 V 11:25:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310300 Vs 11:26:02 Temperature Measurement, Probe Number = 0, T = 20.179000 C 11:26:03 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:26:03 Temperature Measurement, Probe Number = 2, T = 20.018000 C 11:26:04 Temperature Measurement, Probe Number = 3, T = 19.970000 C 11:26:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:26:04 Integrated Voltage Measurement... 11:26:23 Voltage Offset Correction: v_off_ini = 0.000001764 V, v_off_fin = 0.000005854 V 11:26:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417337 Vs 11:26:24 Integrated Voltage Measurement... 11:26:43 Voltage Offset Correction: v_off_ini = 0.000005071 V, v_off_fin = -0.000002217 V 11:26:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302528 Vs 11:26:46 Temperature Measurement, Probe Number = 0, T = 20.250000 C 11:26:46 Temperature Measurement, Probe Number = 1, T = 20.044000 C 11:26:47 Temperature Measurement, Probe Number = 2, T = 20.018000 C 11:26:48 Temperature Measurement, Probe Number = 3, T = 19.970000 C 11:26:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:26:48 Integrated Voltage Measurement... 11:27:07 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = 0.000007966 V 11:27:07 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420518 Vs 11:27:07 Integrated Voltage Measurement... 11:27:26 Voltage Offset Correction: v_off_ini = 0.000004950 V, v_off_fin = -0.000002227 V 11:27:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310147 Vs 11:27:29 Temperature Measurement, Probe Number = 0, T = 20.287000 C 11:27:30 Temperature Measurement, Probe Number = 1, T = 20.048000 C 11:27:31 Temperature Measurement, Probe Number = 2, T = 20.020000 C 11:27:31 Temperature Measurement, Probe Number = 3, T = 19.975000 C 11:27:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:27:31 Integrated Voltage Measurement... 11:27:51 Voltage Offset Correction: v_off_ini = 0.000000804 V, v_off_fin = 0.000006092 V 11:27:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419204 Vs 11:27:51 Integrated Voltage Measurement... 11:28:10 Voltage Offset Correction: v_off_ini = 0.000004806 V, v_off_fin = -0.000002029 V 11:28:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310775 Vs 11:28:13 Temperature Measurement, Probe Number = 0, T = 20.344000 C 11:28:14 Temperature Measurement, Probe Number = 1, T = 20.048000 C 11:28:15 Temperature Measurement, Probe Number = 2, T = 20.019000 C 11:28:15 Temperature Measurement, Probe Number = 3, T = 19.973000 C 11:28:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.97 11:28:15 Integrated Voltage Measurement... 11:28:35 Voltage Offset Correction: v_off_ini = 0.000001514 V, v_off_fin = 0.000006248 V 11:28:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426433 Vs 11:28:35 Integrated Voltage Measurement... 11:28:54 Voltage Offset Correction: v_off_ini = 0.000005437 V, v_off_fin = -0.000002371 V 11:28:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304330 Vs 11:58:57 Temperature Measurement, Probe Number = 0, T = 20.306000 C 11:58:58 Temperature Measurement, Probe Number = 1, T = 20.048000 C 11:58:58 Temperature Measurement, Probe Number = 2, T = 20.025000 C 11:58:59 Temperature Measurement, Probe Number = 3, T = 19.978000 C 11:58:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:58:59 Integrated Voltage Measurement... 11:59:18 Voltage Offset Correction: v_off_ini = 0.000003425 V, v_off_fin = 0.000005684 V 11:59:19 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175518727 Vs 11:59:19 Integrated Voltage Measurement... 11:59:38 Voltage Offset Correction: v_off_ini = 0.000005158 V, v_off_fin = -0.000001927 V 11:59:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297347 Vs 11:59:41 Temperature Measurement, Probe Number = 0, T = 20.334000 C 11:59:41 Temperature Measurement, Probe Number = 1, T = 20.047000 C 11:59:42 Temperature Measurement, Probe Number = 2, T = 20.025000 C 11:59:43 Temperature Measurement, Probe Number = 3, T = 19.977000 C 11:59:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.98 11:59:43 Integrated Voltage Measurement... 12:00:02 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000006010 V 12:00:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411612 Vs 12:00:02 Integrated Voltage Measurement... 12:00:21 Voltage Offset Correction: v_off_ini = 0.000004576 V, v_off_fin = -0.000002889 V 12:00:22 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309433 Vs 12:00:24 Temperature Measurement, Probe Number = 0, T = 20.229000 C 12:00:25 Temperature Measurement, Probe Number = 1, T = 20.049000 C 12:00:26 Temperature Measurement, Probe Number = 2, T = 20.028000 C 12:00:26 Temperature Measurement, Probe Number = 3, T = 19.977000 C 12:00:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:00:26 Integrated Voltage Measurement... 12:00:46 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = 0.000005837 V 12:00:46 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175418078 Vs 12:00:46 Integrated Voltage Measurement... 12:01:05 Voltage Offset Correction: v_off_ini = 0.000005171 V, v_off_fin = -0.000001548 V 12:01:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308990 Vs 12:01:08 Temperature Measurement, Probe Number = 0, T = 20.246000 C 12:01:09 Temperature Measurement, Probe Number = 1, T = 20.053000 C 12:01:10 Temperature Measurement, Probe Number = 2, T = 20.030000 C 12:01:10 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:01:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:01:10 Integrated Voltage Measurement... 12:01:30 Voltage Offset Correction: v_off_ini = 0.000001332 V, v_off_fin = 0.000005737 V 12:01:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415027 Vs 12:01:30 Integrated Voltage Measurement... 12:01:49 Voltage Offset Correction: v_off_ini = 0.000004879 V, v_off_fin = -0.000002422 V 12:01:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304465 Vs 12:01:52 Temperature Measurement, Probe Number = 0, T = 20.306000 C 12:01:53 Temperature Measurement, Probe Number = 1, T = 20.053000 C 12:01:54 Temperature Measurement, Probe Number = 2, T = 20.028000 C 12:01:54 Temperature Measurement, Probe Number = 3, T = 19.979000 C 12:01:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:01:55 Integrated Voltage Measurement... 12:02:14 Voltage Offset Correction: v_off_ini = 0.000001659 V, v_off_fin = 0.000005797 V 12:02:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416320 Vs 12:02:14 Integrated Voltage Measurement... 12:02:34 Voltage Offset Correction: v_off_ini = 0.000004683 V, v_off_fin = -0.000002498 V 12:02:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299376 Vs 12:02:37 Temperature Measurement, Probe Number = 0, T = 20.364000 C 12:02:37 Temperature Measurement, Probe Number = 1, T = 20.054000 C 12:02:38 Temperature Measurement, Probe Number = 2, T = 20.032000 C 12:02:39 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:02:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:02:39 Integrated Voltage Measurement... 12:02:58 Voltage Offset Correction: v_off_ini = 0.000001269 V, v_off_fin = 0.000005753 V 12:02:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412460 Vs 12:02:58 Integrated Voltage Measurement... 12:03:17 Voltage Offset Correction: v_off_ini = 0.000005267 V, v_off_fin = -0.000002822 V 12:03:18 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175307607 Vs 12:03:20 Temperature Measurement, Probe Number = 0, T = 20.369000 C 12:03:21 Temperature Measurement, Probe Number = 1, T = 20.052000 C 12:03:22 Temperature Measurement, Probe Number = 2, T = 20.033000 C 12:03:22 Temperature Measurement, Probe Number = 3, T = 19.979000 C 12:03:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:03:22 Integrated Voltage Measurement... 12:03:42 Voltage Offset Correction: v_off_ini = 0.000001494 V, v_off_fin = 0.000005417 V 12:03:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413937 Vs 12:03:42 Integrated Voltage Measurement... 12:04:01 Voltage Offset Correction: v_off_ini = 0.000004918 V, v_off_fin = -0.000002403 V 12:04:01 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175302435 Vs 12:04:04 Temperature Measurement, Probe Number = 0, T = 20.446000 C 12:04:05 Temperature Measurement, Probe Number = 1, T = 20.054000 C 12:04:05 Temperature Measurement, Probe Number = 2, T = 20.034000 C 12:04:06 Temperature Measurement, Probe Number = 3, T = 19.982000 C 12:04:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:04:06 Integrated Voltage Measurement... 12:04:25 Voltage Offset Correction: v_off_ini = 0.000000979 V, v_off_fin = 0.000005282 V 12:04:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413244 Vs 12:04:26 Integrated Voltage Measurement... 12:04:45 Voltage Offset Correction: v_off_ini = 0.000004728 V, v_off_fin = -0.000002617 V 12:04:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305768 Vs 12:04:48 Temperature Measurement, Probe Number = 0, T = 20.475000 C 12:04:49 Temperature Measurement, Probe Number = 1, T = 20.056000 C 12:04:49 Temperature Measurement, Probe Number = 2, T = 20.036000 C 12:04:50 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:04:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.98 12:04:50 Integrated Voltage Measurement... 12:05:09 Voltage Offset Correction: v_off_ini = 0.000000513 V, v_off_fin = 0.000005345 V 12:05:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409013 Vs 12:05:10 Integrated Voltage Measurement... 12:05:29 Voltage Offset Correction: v_off_ini = 0.000004302 V, v_off_fin = -0.000001556 V 12:05:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303866 Vs 12:05:32 Temperature Measurement, Probe Number = 0, T = 20.496000 C 12:05:32 Temperature Measurement, Probe Number = 1, T = 20.053000 C 12:05:33 Temperature Measurement, Probe Number = 2, T = 20.034000 C 12:05:34 Temperature Measurement, Probe Number = 3, T = 19.982000 C 12:05:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 19.98 12:05:34 Integrated Voltage Measurement... 12:05:53 Voltage Offset Correction: v_off_ini = 0.000001136 V, v_off_fin = 0.000006358 V 12:05:53 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423519 Vs 12:05:54 Integrated Voltage Measurement... 12:06:13 Voltage Offset Correction: v_off_ini = 0.000005386 V, v_off_fin = -0.000002637 V 12:06:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309411 Vs 12:36:16 Temperature Measurement, Probe Number = 0, T = 20.484000 C 12:36:17 Temperature Measurement, Probe Number = 1, T = 20.058000 C 12:36:17 Temperature Measurement, Probe Number = 2, T = 20.039000 C 12:36:18 Temperature Measurement, Probe Number = 3, T = 19.989000 C 12:36:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:36:18 Integrated Voltage Measurement... 12:36:37 Voltage Offset Correction: v_off_ini = 0.000003195 V, v_off_fin = 0.000005734 V 12:36:37 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175510310 Vs 12:36:37 Integrated Voltage Measurement... 12:36:57 Voltage Offset Correction: v_off_ini = 0.000004542 V, v_off_fin = -0.000003132 V 12:36:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175310937 Vs 12:37:00 Temperature Measurement, Probe Number = 0, T = 20.480000 C 12:37:00 Temperature Measurement, Probe Number = 1, T = 20.060000 C 12:37:01 Temperature Measurement, Probe Number = 2, T = 20.040000 C 12:37:01 Temperature Measurement, Probe Number = 3, T = 19.988000 C 12:37:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:37:02 Integrated Voltage Measurement... 12:37:21 Voltage Offset Correction: v_off_ini = -0.000000703 V, v_off_fin = 0.000005214 V 12:37:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175404270 Vs 12:37:21 Integrated Voltage Measurement... 12:37:40 Voltage Offset Correction: v_off_ini = 0.000004391 V, v_off_fin = -0.000003077 V 12:37:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302270 Vs 12:37:43 Temperature Measurement, Probe Number = 0, T = 20.478000 C 12:37:44 Temperature Measurement, Probe Number = 1, T = 20.058000 C 12:37:44 Temperature Measurement, Probe Number = 2, T = 20.038000 C 12:37:45 Temperature Measurement, Probe Number = 3, T = 19.988000 C 12:37:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:37:45 Integrated Voltage Measurement... 12:38:04 Voltage Offset Correction: v_off_ini = -0.000000078 V, v_off_fin = 0.000005642 V 12:38:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408104 Vs 12:38:05 Integrated Voltage Measurement... 12:38:24 Voltage Offset Correction: v_off_ini = 0.000004838 V, v_off_fin = -0.000002583 V 12:38:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300324 Vs 12:38:27 Temperature Measurement, Probe Number = 0, T = 20.461000 C 12:38:28 Temperature Measurement, Probe Number = 1, T = 20.060000 C 12:38:28 Temperature Measurement, Probe Number = 2, T = 20.038000 C 12:38:29 Temperature Measurement, Probe Number = 3, T = 19.992000 C 12:38:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:38:29 Integrated Voltage Measurement... 12:38:48 Voltage Offset Correction: v_off_ini = 0.000000057 V, v_off_fin = 0.000004905 V 12:38:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401774 Vs 12:38:49 Integrated Voltage Measurement... 12:39:08 Voltage Offset Correction: v_off_ini = 0.000004352 V, v_off_fin = -0.000003251 V 12:39:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309925 Vs 12:39:11 Temperature Measurement, Probe Number = 0, T = 20.431000 C 12:39:11 Temperature Measurement, Probe Number = 1, T = 20.061000 C 12:39:12 Temperature Measurement, Probe Number = 2, T = 20.038000 C 12:39:13 Temperature Measurement, Probe Number = 3, T = 19.992000 C 12:39:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:39:13 Integrated Voltage Measurement... 12:39:32 Voltage Offset Correction: v_off_ini = 0.000001486 V, v_off_fin = 0.000005648 V 12:39:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410922 Vs 12:39:32 Integrated Voltage Measurement... 12:39:51 Voltage Offset Correction: v_off_ini = 0.000004511 V, v_off_fin = -0.000002980 V 12:39:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305737 Vs 12:39:54 Temperature Measurement, Probe Number = 0, T = 20.464000 C 12:39:55 Temperature Measurement, Probe Number = 1, T = 20.060000 C 12:39:55 Temperature Measurement, Probe Number = 2, T = 20.036000 C 12:39:56 Temperature Measurement, Probe Number = 3, T = 19.989000 C 12:39:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:39:56 Integrated Voltage Measurement... 12:40:15 Voltage Offset Correction: v_off_ini = 0.000001251 V, v_off_fin = 0.000006323 V 12:40:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413243 Vs 12:40:16 Integrated Voltage Measurement... 12:40:35 Voltage Offset Correction: v_off_ini = 0.000004947 V, v_off_fin = -0.000001735 V 12:40:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305361 Vs 12:40:38 Temperature Measurement, Probe Number = 0, T = 20.465000 C 12:40:39 Temperature Measurement, Probe Number = 1, T = 20.059000 C 12:40:39 Temperature Measurement, Probe Number = 2, T = 20.037000 C 12:40:40 Temperature Measurement, Probe Number = 3, T = 19.988000 C 12:40:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:40:40 Integrated Voltage Measurement... 12:41:00 Voltage Offset Correction: v_off_ini = 0.000001271 V, v_off_fin = 0.000005978 V 12:41:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413248 Vs 12:41:00 Integrated Voltage Measurement... 12:41:19 Voltage Offset Correction: v_off_ini = 0.000005149 V, v_off_fin = -0.000003012 V 12:41:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298778 Vs 12:41:22 Temperature Measurement, Probe Number = 0, T = 20.485000 C 12:41:23 Temperature Measurement, Probe Number = 1, T = 20.060000 C 12:41:24 Temperature Measurement, Probe Number = 2, T = 20.038000 C 12:41:24 Temperature Measurement, Probe Number = 3, T = 19.990000 C 12:41:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:41:24 Integrated Voltage Measurement... 12:41:43 Voltage Offset Correction: v_off_ini = 0.000000665 V, v_off_fin = 0.000004899 V 12:41:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404435 Vs 12:41:44 Integrated Voltage Measurement... 12:42:04 Voltage Offset Correction: v_off_ini = 0.000004567 V, v_off_fin = -0.000002592 V 12:42:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311911 Vs 12:42:06 Temperature Measurement, Probe Number = 0, T = 20.486000 C 12:42:07 Temperature Measurement, Probe Number = 1, T = 20.059000 C 12:42:08 Temperature Measurement, Probe Number = 2, T = 20.038000 C 12:42:08 Temperature Measurement, Probe Number = 3, T = 19.991000 C 12:42:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:42:09 Integrated Voltage Measurement... 12:42:28 Voltage Offset Correction: v_off_ini = 0.000000800 V, v_off_fin = 0.000005649 V 12:42:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175401557 Vs 12:42:28 Integrated Voltage Measurement... 12:42:47 Voltage Offset Correction: v_off_ini = 0.000005085 V, v_off_fin = -0.000002743 V 12:42:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301972 Vs 12:42:50 Temperature Measurement, Probe Number = 0, T = 20.522000 C 12:42:51 Temperature Measurement, Probe Number = 1, T = 20.058000 C 12:42:52 Temperature Measurement, Probe Number = 2, T = 20.039000 C 12:42:52 Temperature Measurement, Probe Number = 3, T = 19.987000 C 12:42:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 12:42:52 Integrated Voltage Measurement... 12:43:12 Voltage Offset Correction: v_off_ini = 0.000000931 V, v_off_fin = 0.000005919 V 12:43:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410067 Vs 12:43:12 Integrated Voltage Measurement... 12:43:32 Voltage Offset Correction: v_off_ini = 0.000004530 V, v_off_fin = -0.000001783 V 12:43:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299560 Vs 13:13:34 Temperature Measurement, Probe Number = 0, T = 20.301000 C 13:13:35 Temperature Measurement, Probe Number = 1, T = 20.060000 C 13:13:36 Temperature Measurement, Probe Number = 2, T = 20.040000 C 13:13:36 Temperature Measurement, Probe Number = 3, T = 19.990000 C 13:13:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 13:13:37 Integrated Voltage Measurement... 13:13:56 Voltage Offset Correction: v_off_ini = 0.000002221 V, v_off_fin = 0.000005822 V 13:13:56 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175504178 Vs 13:13:56 Integrated Voltage Measurement... 13:14:16 Voltage Offset Correction: v_off_ini = 0.000005094 V, v_off_fin = -0.000002475 V 13:14:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286308 Vs 13:14:18 Temperature Measurement, Probe Number = 0, T = 20.274000 C 13:14:19 Temperature Measurement, Probe Number = 1, T = 20.064000 C 13:14:20 Temperature Measurement, Probe Number = 2, T = 20.044000 C 13:14:20 Temperature Measurement, Probe Number = 3, T = 19.994000 C 13:14:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 19.99 13:14:21 Integrated Voltage Measurement... 13:14:41 Voltage Offset Correction: v_off_ini = 0.000001513 V, v_off_fin = 0.000005310 V 13:14:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412046 Vs 13:14:41 Integrated Voltage Measurement... 13:15:01 Voltage Offset Correction: v_off_ini = 0.000005048 V, v_off_fin = -0.000001209 V 13:15:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285965 Vs 13:15:03 Temperature Measurement, Probe Number = 0, T = 20.320000 C 13:15:04 Temperature Measurement, Probe Number = 1, T = 20.066000 C 13:15:05 Temperature Measurement, Probe Number = 2, T = 20.045000 C 13:15:05 Temperature Measurement, Probe Number = 3, T = 19.994000 C 13:15:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 19.99 13:15:06 Integrated Voltage Measurement... 13:15:25 Voltage Offset Correction: v_off_ini = 0.000001183 V, v_off_fin = 0.000005870 V 13:15:25 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175404704 Vs 13:15:25 Integrated Voltage Measurement... 13:15:44 Voltage Offset Correction: v_off_ini = 0.000004846 V, v_off_fin = -0.000001420 V 13:15:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301635 Vs 13:15:47 Temperature Measurement, Probe Number = 0, T = 20.330000 C 13:15:48 Temperature Measurement, Probe Number = 1, T = 20.067000 C 13:15:48 Temperature Measurement, Probe Number = 2, T = 20.045000 C 13:15:49 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:15:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:15:49 Integrated Voltage Measurement... 13:16:08 Voltage Offset Correction: v_off_ini = 0.000001291 V, v_off_fin = 0.000005518 V 13:16:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405023 Vs 13:16:09 Integrated Voltage Measurement... 13:16:28 Voltage Offset Correction: v_off_ini = 0.000004935 V, v_off_fin = -0.000003028 V 13:16:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175294205 Vs 13:16:31 Temperature Measurement, Probe Number = 0, T = 20.289000 C 13:16:31 Temperature Measurement, Probe Number = 1, T = 20.065000 C 13:16:32 Temperature Measurement, Probe Number = 2, T = 20.045000 C 13:16:33 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:16:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:16:33 Integrated Voltage Measurement... 13:16:52 Voltage Offset Correction: v_off_ini = 0.000000407 V, v_off_fin = 0.000005539 V 13:16:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407137 Vs 13:16:52 Integrated Voltage Measurement... 13:17:12 Voltage Offset Correction: v_off_ini = 0.000005021 V, v_off_fin = -0.000003215 V 13:17:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302493 Vs 13:17:15 Temperature Measurement, Probe Number = 0, T = 20.299000 C 13:17:15 Temperature Measurement, Probe Number = 1, T = 20.066000 C 13:17:16 Temperature Measurement, Probe Number = 2, T = 20.045000 C 13:17:17 Temperature Measurement, Probe Number = 3, T = 19.997000 C 13:17:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:17:17 Integrated Voltage Measurement... 13:17:36 Voltage Offset Correction: v_off_ini = 0.000000964 V, v_off_fin = 0.000005656 V 13:17:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406249 Vs 13:17:36 Integrated Voltage Measurement... 13:17:55 Voltage Offset Correction: v_off_ini = 0.000005067 V, v_off_fin = -0.000002660 V 13:17:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297300 Vs 13:17:58 Temperature Measurement, Probe Number = 0, T = 20.304000 C 13:17:59 Temperature Measurement, Probe Number = 1, T = 20.067000 C 13:18:00 Temperature Measurement, Probe Number = 2, T = 20.044000 C 13:18:00 Temperature Measurement, Probe Number = 3, T = 19.995000 C 13:18:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 13:18:00 Integrated Voltage Measurement... 13:18:20 Voltage Offset Correction: v_off_ini = 0.000001243 V, v_off_fin = 0.000005340 V 13:18:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409164 Vs 13:18:20 Integrated Voltage Measurement... 13:18:39 Voltage Offset Correction: v_off_ini = 0.000004411 V, v_off_fin = -0.000003329 V 13:18:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296400 Vs 13:18:42 Temperature Measurement, Probe Number = 0, T = 20.372000 C 13:18:43 Temperature Measurement, Probe Number = 1, T = 20.065000 C 13:18:43 Temperature Measurement, Probe Number = 2, T = 20.042000 C 13:18:44 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:18:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 13:18:44 Integrated Voltage Measurement... 13:19:04 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000005418 V 13:19:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406371 Vs 13:19:04 Integrated Voltage Measurement... 13:19:23 Voltage Offset Correction: v_off_ini = 0.000005186 V, v_off_fin = -0.000002609 V 13:19:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299430 Vs 13:19:26 Temperature Measurement, Probe Number = 0, T = 20.437000 C 13:19:27 Temperature Measurement, Probe Number = 1, T = 20.065000 C 13:19:27 Temperature Measurement, Probe Number = 2, T = 20.043000 C 13:19:28 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:19:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.00 13:19:28 Integrated Voltage Measurement... 13:19:47 Voltage Offset Correction: v_off_ini = 0.000000941 V, v_off_fin = 0.000005315 V 13:19:47 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175399028 Vs 13:19:47 Integrated Voltage Measurement... 13:20:07 Voltage Offset Correction: v_off_ini = 0.000004461 V, v_off_fin = -0.000003184 V 13:20:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304311 Vs 13:20:10 Temperature Measurement, Probe Number = 0, T = 20.475000 C 13:20:10 Temperature Measurement, Probe Number = 1, T = 20.067000 C 13:20:11 Temperature Measurement, Probe Number = 2, T = 20.045000 C 13:20:12 Temperature Measurement, Probe Number = 3, T = 19.996000 C 13:20:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:20:12 Integrated Voltage Measurement... 13:20:31 Voltage Offset Correction: v_off_ini = 0.000000370 V, v_off_fin = 0.000004914 V 13:20:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175398448 Vs 13:20:31 Integrated Voltage Measurement... 13:20:50 Voltage Offset Correction: v_off_ini = 0.000004396 V, v_off_fin = -0.000002393 V 13:20:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299025 Vs 13:50:53 Temperature Measurement, Probe Number = 0, T = 20.448000 C 13:50:54 Temperature Measurement, Probe Number = 1, T = 20.074000 C 13:50:55 Temperature Measurement, Probe Number = 2, T = 20.052000 C 13:50:55 Temperature Measurement, Probe Number = 3, T = 20.004000 C 13:50:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:50:55 Integrated Voltage Measurement... 13:51:16 Voltage Offset Correction: v_off_ini = 0.000002316 V, v_off_fin = 0.000004860 V 13:51:16 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175505975 Vs 13:51:16 Integrated Voltage Measurement... 13:51:36 Voltage Offset Correction: v_off_ini = 0.000004325 V, v_off_fin = -0.000002231 V 13:51:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175287266 Vs 13:51:39 Temperature Measurement, Probe Number = 0, T = 20.449000 C 13:51:39 Temperature Measurement, Probe Number = 1, T = 20.076000 C 13:51:40 Temperature Measurement, Probe Number = 2, T = 20.058000 C 13:51:41 Temperature Measurement, Probe Number = 3, T = 20.007000 C 13:51:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:51:41 Integrated Voltage Measurement... 13:52:00 Voltage Offset Correction: v_off_ini = 0.000001318 V, v_off_fin = 0.000005259 V 13:52:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175383099 Vs 13:52:00 Integrated Voltage Measurement... 13:52:20 Voltage Offset Correction: v_off_ini = 0.000005472 V, v_off_fin = -0.000001560 V 13:52:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284689 Vs 13:52:23 Temperature Measurement, Probe Number = 0, T = 20.433000 C 13:52:24 Temperature Measurement, Probe Number = 1, T = 20.075000 C 13:52:24 Temperature Measurement, Probe Number = 2, T = 20.058000 C 13:52:25 Temperature Measurement, Probe Number = 3, T = 20.006000 C 13:52:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:52:25 Integrated Voltage Measurement... 13:52:44 Voltage Offset Correction: v_off_ini = 0.000000951 V, v_off_fin = 0.000004710 V 13:52:44 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175385216 Vs 13:52:44 Integrated Voltage Measurement... 13:53:03 Voltage Offset Correction: v_off_ini = 0.000004163 V, v_off_fin = -0.000003174 V 13:53:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290177 Vs 13:53:06 Temperature Measurement, Probe Number = 0, T = 20.378000 C 13:53:07 Temperature Measurement, Probe Number = 1, T = 20.072000 C 13:53:07 Temperature Measurement, Probe Number = 2, T = 20.055000 C 13:53:08 Temperature Measurement, Probe Number = 3, T = 20.002000 C 13:53:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:53:08 Integrated Voltage Measurement... 13:53:27 Voltage Offset Correction: v_off_ini = 0.000000702 V, v_off_fin = 0.000004713 V 13:53:27 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175396384 Vs 13:53:28 Integrated Voltage Measurement... 13:53:47 Voltage Offset Correction: v_off_ini = 0.000004117 V, v_off_fin = -0.000003278 V 13:53:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300187 Vs 13:53:50 Temperature Measurement, Probe Number = 0, T = 20.381000 C 13:53:51 Temperature Measurement, Probe Number = 1, T = 20.073000 C 13:53:51 Temperature Measurement, Probe Number = 2, T = 20.055000 C 13:53:52 Temperature Measurement, Probe Number = 3, T = 20.004000 C 13:53:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.00 13:53:52 Integrated Voltage Measurement... 13:54:11 Voltage Offset Correction: v_off_ini = 0.000000205 V, v_off_fin = 0.000005011 V 13:54:11 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175383567 Vs 13:54:12 Integrated Voltage Measurement... 13:54:31 Voltage Offset Correction: v_off_ini = 0.000004249 V, v_off_fin = -0.000002983 V 13:54:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299880 Vs 13:54:34 Temperature Measurement, Probe Number = 0, T = 20.437000 C 13:54:35 Temperature Measurement, Probe Number = 1, T = 20.076000 C 13:54:35 Temperature Measurement, Probe Number = 2, T = 20.059000 C 13:54:36 Temperature Measurement, Probe Number = 3, T = 20.007000 C 13:54:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:54:36 Integrated Voltage Measurement... 13:54:55 Voltage Offset Correction: v_off_ini = 0.000000015 V, v_off_fin = 0.000004948 V 13:54:56 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175387640 Vs 13:54:56 Integrated Voltage Measurement... 13:55:15 Voltage Offset Correction: v_off_ini = 0.000004393 V, v_off_fin = -0.000002466 V 13:55:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290005 Vs 13:55:18 Temperature Measurement, Probe Number = 0, T = 20.430000 C 13:55:19 Temperature Measurement, Probe Number = 1, T = 20.079000 C 13:55:19 Temperature Measurement, Probe Number = 2, T = 20.063000 C 13:55:20 Temperature Measurement, Probe Number = 3, T = 20.010000 C 13:55:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:55:20 Integrated Voltage Measurement... 13:55:39 Voltage Offset Correction: v_off_ini = 0.000001127 V, v_off_fin = 0.000005541 V 13:55:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175392129 Vs 13:55:39 Integrated Voltage Measurement... 13:55:59 Voltage Offset Correction: v_off_ini = 0.000004989 V, v_off_fin = -0.000002745 V 13:55:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291478 Vs 13:56:01 Temperature Measurement, Probe Number = 0, T = 20.481000 C 13:56:02 Temperature Measurement, Probe Number = 1, T = 20.080000 C 13:56:03 Temperature Measurement, Probe Number = 2, T = 20.063000 C 13:56:03 Temperature Measurement, Probe Number = 3, T = 20.009000 C 13:56:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:56:03 Integrated Voltage Measurement... 13:56:23 Voltage Offset Correction: v_off_ini = 0.000000632 V, v_off_fin = 0.000005536 V 13:56:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175398107 Vs 13:56:23 Integrated Voltage Measurement... 13:56:42 Voltage Offset Correction: v_off_ini = 0.000005125 V, v_off_fin = -0.000002361 V 13:56:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287560 Vs 13:56:45 Temperature Measurement, Probe Number = 0, T = 20.525000 C 13:56:46 Temperature Measurement, Probe Number = 1, T = 20.077000 C 13:56:46 Temperature Measurement, Probe Number = 2, T = 20.060000 C 13:56:47 Temperature Measurement, Probe Number = 3, T = 20.009000 C 13:56:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:56:47 Integrated Voltage Measurement... 13:57:06 Voltage Offset Correction: v_off_ini = 0.000000273 V, v_off_fin = 0.000005711 V 13:57:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175392429 Vs 13:57:06 Integrated Voltage Measurement... 13:57:26 Voltage Offset Correction: v_off_ini = 0.000004043 V, v_off_fin = -0.000003175 V 13:57:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291953 Vs 13:57:28 Temperature Measurement, Probe Number = 0, T = 20.559000 C 13:57:29 Temperature Measurement, Probe Number = 1, T = 20.077000 C 13:57:30 Temperature Measurement, Probe Number = 2, T = 20.057000 C 13:57:30 Temperature Measurement, Probe Number = 3, T = 20.007000 C 13:57:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.56 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 13:57:30 Integrated Voltage Measurement... 13:57:50 Voltage Offset Correction: v_off_ini = 0.000000572 V, v_off_fin = 0.000005090 V 13:57:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175385569 Vs 13:57:50 Integrated Voltage Measurement... 13:58:09 Voltage Offset Correction: v_off_ini = 0.000004402 V, v_off_fin = -0.000002986 V 13:58:09 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175287419 Vs 14:28:11 Temperature Measurement, Probe Number = 0, T = 20.492000 C 14:28:12 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:28:13 Temperature Measurement, Probe Number = 2, T = 20.066000 C 14:28:13 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:28:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:28:14 Integrated Voltage Measurement... 14:28:33 Voltage Offset Correction: v_off_ini = 0.000003752 V, v_off_fin = 0.000005577 V 14:28:34 Integrated Voltage Measurement Delta Gap = 0.0040037 m VT = 0.175513236 Vs 14:28:34 Integrated Voltage Measurement... 14:28:53 Voltage Offset Correction: v_off_ini = 0.000004952 V, v_off_fin = -0.000002127 V 14:28:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281877 Vs 14:28:56 Temperature Measurement, Probe Number = 0, T = 20.455000 C 14:28:57 Temperature Measurement, Probe Number = 1, T = 20.082000 C 14:28:57 Temperature Measurement, Probe Number = 2, T = 20.067000 C 14:28:58 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:28:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:28:58 Integrated Voltage Measurement... 14:29:17 Voltage Offset Correction: v_off_ini = 0.000002010 V, v_off_fin = 0.000006030 V 14:29:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396037 Vs 14:29:18 Integrated Voltage Measurement... 14:29:37 Voltage Offset Correction: v_off_ini = 0.000005264 V, v_off_fin = -0.000002246 V 14:29:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175272498 Vs 14:29:39 Temperature Measurement, Probe Number = 0, T = 20.425000 C 14:29:40 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:29:41 Temperature Measurement, Probe Number = 2, T = 20.067000 C 14:29:41 Temperature Measurement, Probe Number = 3, T = 20.013000 C 14:29:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.01 14:29:42 Integrated Voltage Measurement... 14:30:01 Voltage Offset Correction: v_off_ini = 0.000000871 V, v_off_fin = 0.000005319 V 14:30:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175389423 Vs 14:30:01 Integrated Voltage Measurement... 14:30:20 Voltage Offset Correction: v_off_ini = 0.000004661 V, v_off_fin = -0.000002291 V 14:30:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280705 Vs 14:30:23 Temperature Measurement, Probe Number = 0, T = 20.445000 C 14:30:24 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:30:24 Temperature Measurement, Probe Number = 2, T = 20.067000 C 14:30:25 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:30:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:30:25 Integrated Voltage Measurement... 14:30:44 Voltage Offset Correction: v_off_ini = 0.000002041 V, v_off_fin = 0.000005977 V 14:30:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175393299 Vs 14:30:45 Integrated Voltage Measurement... 14:31:04 Voltage Offset Correction: v_off_ini = 0.000005421 V, v_off_fin = -0.000002010 V 14:31:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175271948 Vs 14:31:06 Temperature Measurement, Probe Number = 0, T = 20.481000 C 14:31:07 Temperature Measurement, Probe Number = 1, T = 20.084000 C 14:31:08 Temperature Measurement, Probe Number = 2, T = 20.064000 C 14:31:08 Temperature Measurement, Probe Number = 3, T = 20.014000 C 14:31:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.01 14:31:09 Integrated Voltage Measurement... 14:31:28 Voltage Offset Correction: v_off_ini = 0.000001255 V, v_off_fin = 0.000005659 V 14:31:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175393446 Vs 14:31:28 Integrated Voltage Measurement... 14:31:48 Voltage Offset Correction: v_off_ini = 0.000005029 V, v_off_fin = -0.000001921 V 14:31:48 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175283816 Vs 14:31:50 Temperature Measurement, Probe Number = 0, T = 20.461000 C 14:31:51 Temperature Measurement, Probe Number = 1, T = 20.082000 C 14:31:52 Temperature Measurement, Probe Number = 2, T = 20.066000 C 14:31:52 Temperature Measurement, Probe Number = 3, T = 20.016000 C 14:31:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:31:53 Integrated Voltage Measurement... 14:32:12 Voltage Offset Correction: v_off_ini = 0.000001648 V, v_off_fin = 0.000004704 V 14:32:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175385597 Vs 14:32:12 Integrated Voltage Measurement... 14:32:31 Voltage Offset Correction: v_off_ini = 0.000004911 V, v_off_fin = -0.000001367 V 14:32:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175277532 Vs 14:32:34 Temperature Measurement, Probe Number = 0, T = 20.387000 C 14:32:35 Temperature Measurement, Probe Number = 1, T = 20.082000 C 14:32:35 Temperature Measurement, Probe Number = 2, T = 20.063000 C 14:32:36 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:32:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:32:36 Integrated Voltage Measurement... 14:32:55 Voltage Offset Correction: v_off_ini = 0.000001314 V, v_off_fin = 0.000005110 V 14:32:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175390721 Vs 14:32:55 Integrated Voltage Measurement... 14:33:14 Voltage Offset Correction: v_off_ini = 0.000004913 V, v_off_fin = -0.000002381 V 14:33:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282025 Vs 14:33:17 Temperature Measurement, Probe Number = 0, T = 20.310000 C 14:33:18 Temperature Measurement, Probe Number = 1, T = 20.085000 C 14:33:19 Temperature Measurement, Probe Number = 2, T = 20.063000 C 14:33:19 Temperature Measurement, Probe Number = 3, T = 20.015000 C 14:33:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 14:33:19 Integrated Voltage Measurement... 14:33:39 Voltage Offset Correction: v_off_ini = 0.000000954 V, v_off_fin = 0.000005679 V 14:33:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175392239 Vs 14:33:39 Integrated Voltage Measurement... 14:33:58 Voltage Offset Correction: v_off_ini = 0.000004996 V, v_off_fin = -0.000002239 V 14:33:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175276811 Vs 14:34:01 Temperature Measurement, Probe Number = 0, T = 20.304000 C 14:34:01 Temperature Measurement, Probe Number = 1, T = 20.083000 C 14:34:02 Temperature Measurement, Probe Number = 2, T = 20.066000 C 14:34:03 Temperature Measurement, Probe Number = 3, T = 20.018000 C 14:34:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:34:03 Integrated Voltage Measurement... 14:34:22 Voltage Offset Correction: v_off_ini = 0.000001225 V, v_off_fin = 0.000005898 V 14:34:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175397411 Vs 14:34:22 Integrated Voltage Measurement... 14:34:41 Voltage Offset Correction: v_off_ini = 0.000005171 V, v_off_fin = -0.000002787 V 14:34:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279375 Vs 14:34:44 Temperature Measurement, Probe Number = 0, T = 20.359000 C 14:34:45 Temperature Measurement, Probe Number = 1, T = 20.084000 C 14:34:45 Temperature Measurement, Probe Number = 2, T = 20.068000 C 14:34:46 Temperature Measurement, Probe Number = 3, T = 20.019000 C 14:34:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 14:34:46 Integrated Voltage Measurement... 14:35:05 Voltage Offset Correction: v_off_ini = 0.000000810 V, v_off_fin = 0.000005648 V 14:35:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175395710 Vs 14:35:05 Integrated Voltage Measurement... 14:35:25 Voltage Offset Correction: v_off_ini = 0.000004929 V, v_off_fin = -0.000002449 V 14:35:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282985 Vs 15:05:27 Temperature Measurement, Probe Number = 0, T = 20.431000 C 15:05:28 Temperature Measurement, Probe Number = 1, T = 20.094000 C 15:05:29 Temperature Measurement, Probe Number = 2, T = 20.072000 C 15:05:29 Temperature Measurement, Probe Number = 3, T = 20.025000 C 15:05:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.02 15:05:30 Integrated Voltage Measurement... 15:05:49 Voltage Offset Correction: v_off_ini = 0.000003081 V, v_off_fin = 0.000005153 V 15:05:49 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175490131 Vs 15:05:49 Integrated Voltage Measurement... 15:06:09 Voltage Offset Correction: v_off_ini = 0.000004090 V, v_off_fin = -0.000002323 V 15:06:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283115 Vs 15:06:11 Temperature Measurement, Probe Number = 0, T = 20.431000 C 15:06:12 Temperature Measurement, Probe Number = 1, T = 20.097000 C 15:06:13 Temperature Measurement, Probe Number = 2, T = 20.073000 C 15:06:13 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:06:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:06:13 Integrated Voltage Measurement... 15:06:33 Voltage Offset Correction: v_off_ini = 0.000001226 V, v_off_fin = 0.000005615 V 15:06:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175381989 Vs 15:06:33 Integrated Voltage Measurement... 15:06:52 Voltage Offset Correction: v_off_ini = 0.000004931 V, v_off_fin = -0.000003679 V 15:06:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175281930 Vs 15:06:55 Temperature Measurement, Probe Number = 0, T = 20.426000 C 15:06:55 Temperature Measurement, Probe Number = 1, T = 20.096000 C 15:06:56 Temperature Measurement, Probe Number = 2, T = 20.074000 C 15:06:57 Temperature Measurement, Probe Number = 3, T = 20.029000 C 15:06:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:06:57 Integrated Voltage Measurement... 15:07:16 Voltage Offset Correction: v_off_ini = 0.000000206 V, v_off_fin = 0.000005272 V 15:07:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175385017 Vs 15:07:16 Integrated Voltage Measurement... 15:07:35 Voltage Offset Correction: v_off_ini = 0.000004636 V, v_off_fin = -0.000002234 V 15:07:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283825 Vs 15:07:38 Temperature Measurement, Probe Number = 0, T = 20.432000 C 15:07:39 Temperature Measurement, Probe Number = 1, T = 20.095000 C 15:07:39 Temperature Measurement, Probe Number = 2, T = 20.072000 C 15:07:40 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:07:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:07:40 Integrated Voltage Measurement... 15:08:00 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000005225 V 15:08:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175388963 Vs 15:08:00 Integrated Voltage Measurement... 15:08:19 Voltage Offset Correction: v_off_ini = 0.000004033 V, v_off_fin = -0.000002535 V 15:08:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287238 Vs 15:08:22 Temperature Measurement, Probe Number = 0, T = 20.461000 C 15:08:22 Temperature Measurement, Probe Number = 1, T = 20.096000 C 15:08:23 Temperature Measurement, Probe Number = 2, T = 20.073000 C 15:08:24 Temperature Measurement, Probe Number = 3, T = 20.028000 C 15:08:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:08:24 Integrated Voltage Measurement... 15:08:43 Voltage Offset Correction: v_off_ini = 0.000000716 V, v_off_fin = 0.000005084 V 15:08:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175396962 Vs 15:08:43 Integrated Voltage Measurement... 15:09:03 Voltage Offset Correction: v_off_ini = 0.000004693 V, v_off_fin = -0.000002900 V 15:09:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286998 Vs 15:09:06 Temperature Measurement, Probe Number = 0, T = 20.464000 C 15:09:06 Temperature Measurement, Probe Number = 1, T = 20.094000 C 15:09:07 Temperature Measurement, Probe Number = 2, T = 20.073000 C 15:09:08 Temperature Measurement, Probe Number = 3, T = 20.026000 C 15:09:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:09:08 Integrated Voltage Measurement... 15:09:27 Voltage Offset Correction: v_off_ini = 0.000001289 V, v_off_fin = 0.000005082 V 15:09:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175387334 Vs 15:09:27 Integrated Voltage Measurement... 15:09:46 Voltage Offset Correction: v_off_ini = 0.000004010 V, v_off_fin = -0.000002863 V 15:09:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287165 Vs 15:09:49 Temperature Measurement, Probe Number = 0, T = 20.433000 C 15:09:50 Temperature Measurement, Probe Number = 1, T = 20.096000 C 15:09:50 Temperature Measurement, Probe Number = 2, T = 20.073000 C 15:09:51 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:09:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:09:51 Integrated Voltage Measurement... 15:10:10 Voltage Offset Correction: v_off_ini = 0.000000708 V, v_off_fin = 0.000005187 V 15:10:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175389103 Vs 15:10:11 Integrated Voltage Measurement... 15:10:30 Voltage Offset Correction: v_off_ini = 0.000004654 V, v_off_fin = -0.000002643 V 15:10:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292349 Vs 15:10:33 Temperature Measurement, Probe Number = 0, T = 20.400000 C 15:10:33 Temperature Measurement, Probe Number = 1, T = 20.096000 C 15:10:34 Temperature Measurement, Probe Number = 2, T = 20.075000 C 15:10:35 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:10:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:10:35 Integrated Voltage Measurement... 15:10:54 Voltage Offset Correction: v_off_ini = 0.000000260 V, v_off_fin = 0.000004173 V 15:10:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175380225 Vs 15:10:54 Integrated Voltage Measurement... 15:11:13 Voltage Offset Correction: v_off_ini = 0.000003856 V, v_off_fin = -0.000003393 V 15:11:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293789 Vs 15:11:16 Temperature Measurement, Probe Number = 0, T = 20.411000 C 15:11:17 Temperature Measurement, Probe Number = 1, T = 20.097000 C 15:11:17 Temperature Measurement, Probe Number = 2, T = 20.072000 C 15:11:18 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:11:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:11:18 Integrated Voltage Measurement... 15:11:38 Voltage Offset Correction: v_off_ini = 0.000000385 V, v_off_fin = 0.000004744 V 15:11:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175389469 Vs 15:11:38 Integrated Voltage Measurement... 15:11:57 Voltage Offset Correction: v_off_ini = 0.000004162 V, v_off_fin = -0.000002712 V 15:11:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292014 Vs 15:12:00 Temperature Measurement, Probe Number = 0, T = 20.474000 C 15:12:01 Temperature Measurement, Probe Number = 1, T = 20.097000 C 15:12:01 Temperature Measurement, Probe Number = 2, T = 20.075000 C 15:12:02 Temperature Measurement, Probe Number = 3, T = 20.027000 C 15:12:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 15:12:02 Integrated Voltage Measurement... 15:12:21 Voltage Offset Correction: v_off_ini = 0.000000327 V, v_off_fin = 0.000005292 V 15:12:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175384924 Vs 15:12:22 Integrated Voltage Measurement... 15:12:41 Voltage Offset Correction: v_off_ini = 0.000004806 V, v_off_fin = -0.000002649 V 15:12:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281296 Vs 15:42:43 Temperature Measurement, Probe Number = 0, T = 20.378000 C 15:42:44 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:42:45 Temperature Measurement, Probe Number = 2, T = 20.082000 C 15:42:45 Temperature Measurement, Probe Number = 3, T = 20.036000 C 15:42:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 15:42:46 Integrated Voltage Measurement... 15:43:05 Voltage Offset Correction: v_off_ini = 0.000003349 V, v_off_fin = 0.000005278 V 15:43:05 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175492028 Vs 15:43:05 Integrated Voltage Measurement... 15:43:24 Voltage Offset Correction: v_off_ini = 0.000004084 V, v_off_fin = -0.000003021 V 15:43:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286960 Vs 15:43:27 Temperature Measurement, Probe Number = 0, T = 20.324000 C 15:43:28 Temperature Measurement, Probe Number = 1, T = 20.103000 C 15:43:28 Temperature Measurement, Probe Number = 2, T = 20.082000 C 15:43:29 Temperature Measurement, Probe Number = 3, T = 20.036000 C 15:43:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 15:43:29 Integrated Voltage Measurement... 15:43:48 Voltage Offset Correction: v_off_ini = 0.000000045 V, v_off_fin = 0.000004893 V 15:43:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175385590 Vs 15:43:49 Integrated Voltage Measurement... 15:44:08 Voltage Offset Correction: v_off_ini = 0.000004330 V, v_off_fin = -0.000002068 V 15:44:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283400 Vs 15:44:11 Temperature Measurement, Probe Number = 0, T = 20.313000 C 15:44:12 Temperature Measurement, Probe Number = 1, T = 20.105000 C 15:44:13 Temperature Measurement, Probe Number = 2, T = 20.084000 C 15:44:13 Temperature Measurement, Probe Number = 3, T = 20.038000 C 15:44:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 15:44:13 Integrated Voltage Measurement... 15:44:33 Voltage Offset Correction: v_off_ini = -0.000000130 V, v_off_fin = 0.000005202 V 15:44:33 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175378198 Vs 15:44:33 Integrated Voltage Measurement... 15:44:52 Voltage Offset Correction: v_off_ini = 0.000004656 V, v_off_fin = -0.000002221 V 15:44:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292210 Vs 15:44:55 Temperature Measurement, Probe Number = 0, T = 20.321000 C 15:44:56 Temperature Measurement, Probe Number = 1, T = 20.106000 C 15:44:56 Temperature Measurement, Probe Number = 2, T = 20.085000 C 15:44:57 Temperature Measurement, Probe Number = 3, T = 20.040000 C 15:44:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:44:57 Integrated Voltage Measurement... 15:45:16 Voltage Offset Correction: v_off_ini = 0.000001407 V, v_off_fin = 0.000005638 V 15:45:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175389493 Vs 15:45:16 Integrated Voltage Measurement... 15:45:36 Voltage Offset Correction: v_off_ini = 0.000004677 V, v_off_fin = -0.000002222 V 15:45:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175279912 Vs 15:45:38 Temperature Measurement, Probe Number = 0, T = 20.382000 C 15:45:39 Temperature Measurement, Probe Number = 1, T = 20.105000 C 15:45:40 Temperature Measurement, Probe Number = 2, T = 20.085000 C 15:45:40 Temperature Measurement, Probe Number = 3, T = 20.038000 C 15:45:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:45:41 Integrated Voltage Measurement... 15:46:00 Voltage Offset Correction: v_off_ini = 0.000001025 V, v_off_fin = 0.000005623 V 15:46:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175393563 Vs 15:46:00 Integrated Voltage Measurement... 15:46:19 Voltage Offset Correction: v_off_ini = 0.000004714 V, v_off_fin = -0.000002959 V 15:46:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291172 Vs 15:46:22 Temperature Measurement, Probe Number = 0, T = 20.414000 C 15:46:23 Temperature Measurement, Probe Number = 1, T = 20.106000 C 15:46:23 Temperature Measurement, Probe Number = 2, T = 20.086000 C 15:46:24 Temperature Measurement, Probe Number = 3, T = 20.038000 C 15:46:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:46:24 Integrated Voltage Measurement... 15:46:44 Voltage Offset Correction: v_off_ini = 0.000000611 V, v_off_fin = 0.000004593 V 15:46:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175387538 Vs 15:46:44 Integrated Voltage Measurement... 15:47:03 Voltage Offset Correction: v_off_ini = 0.000004234 V, v_off_fin = -0.000003283 V 15:47:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288659 Vs 15:47:05 Temperature Measurement, Probe Number = 0, T = 20.388000 C 15:47:06 Temperature Measurement, Probe Number = 1, T = 20.107000 C 15:47:07 Temperature Measurement, Probe Number = 2, T = 20.085000 C 15:47:07 Temperature Measurement, Probe Number = 3, T = 20.038000 C 15:47:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:47:08 Integrated Voltage Measurement... 15:47:27 Voltage Offset Correction: v_off_ini = 0.000000241 V, v_off_fin = 0.000005046 V 15:47:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175391461 Vs 15:47:27 Integrated Voltage Measurement... 15:47:46 Voltage Offset Correction: v_off_ini = 0.000004288 V, v_off_fin = -0.000003230 V 15:47:46 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175284885 Vs 15:47:49 Temperature Measurement, Probe Number = 0, T = 20.392000 C 15:47:49 Temperature Measurement, Probe Number = 1, T = 20.107000 C 15:47:50 Temperature Measurement, Probe Number = 2, T = 20.086000 C 15:47:51 Temperature Measurement, Probe Number = 3, T = 20.038000 C 15:47:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:47:51 Integrated Voltage Measurement... 15:48:10 Voltage Offset Correction: v_off_ini = 0.000000329 V, v_off_fin = 0.000005300 V 15:48:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175391028 Vs 15:48:10 Integrated Voltage Measurement... 15:48:29 Voltage Offset Correction: v_off_ini = 0.000004707 V, v_off_fin = -0.000001264 V 15:48:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290618 Vs 15:48:32 Temperature Measurement, Probe Number = 0, T = 20.367000 C 15:48:33 Temperature Measurement, Probe Number = 1, T = 20.111000 C 15:48:33 Temperature Measurement, Probe Number = 2, T = 20.089000 C 15:48:34 Temperature Measurement, Probe Number = 3, T = 20.041000 C 15:48:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:48:34 Integrated Voltage Measurement... 15:48:54 Voltage Offset Correction: v_off_ini = -0.000000073 V, v_off_fin = 0.000004827 V 15:48:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175388941 Vs 15:48:54 Integrated Voltage Measurement... 15:49:13 Voltage Offset Correction: v_off_ini = 0.000004329 V, v_off_fin = -0.000002858 V 15:49:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284517 Vs 15:49:16 Temperature Measurement, Probe Number = 0, T = 20.408000 C 15:49:16 Temperature Measurement, Probe Number = 1, T = 20.111000 C 15:49:17 Temperature Measurement, Probe Number = 2, T = 20.087000 C 15:49:18 Temperature Measurement, Probe Number = 3, T = 20.041000 C 15:49:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.09 P3 = Top 1, Value = 20.04 15:49:18 Integrated Voltage Measurement... 15:49:37 Voltage Offset Correction: v_off_ini = 0.000000306 V, v_off_fin = 0.000005539 V 15:49:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175391186 Vs 15:49:37 Integrated Voltage Measurement... 15:49:57 Voltage Offset Correction: v_off_ini = 0.000004272 V, v_off_fin = -0.000002596 V 15:49:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294963 Vs 16:20:00 Temperature Measurement, Probe Number = 0, T = 20.233000 C 16:20:00 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:20:01 Temperature Measurement, Probe Number = 2, T = 20.079000 C 16:20:02 Temperature Measurement, Probe Number = 3, T = 20.039000 C 16:20:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:20:02 Integrated Voltage Measurement... 16:20:21 Voltage Offset Correction: v_off_ini = 0.000003711 V, v_off_fin = 0.000004669 V 16:20:22 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175489848 Vs 16:20:22 Integrated Voltage Measurement... 16:20:41 Voltage Offset Correction: v_off_ini = 0.000003994 V, v_off_fin = -0.000002890 V 16:20:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291261 Vs 16:20:44 Temperature Measurement, Probe Number = 0, T = 20.248000 C 16:20:44 Temperature Measurement, Probe Number = 1, T = 20.104000 C 16:20:45 Temperature Measurement, Probe Number = 2, T = 20.080000 C 16:20:45 Temperature Measurement, Probe Number = 3, T = 20.042000 C 16:20:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:20:46 Integrated Voltage Measurement... 16:21:05 Voltage Offset Correction: v_off_ini = 0.000000745 V, v_off_fin = 0.000004953 V 16:21:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175390104 Vs 16:21:05 Integrated Voltage Measurement... 16:21:24 Voltage Offset Correction: v_off_ini = 0.000004534 V, v_off_fin = -0.000003017 V 16:21:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175286247 Vs 16:21:27 Temperature Measurement, Probe Number = 0, T = 20.283000 C 16:21:27 Temperature Measurement, Probe Number = 1, T = 20.100000 C 16:21:28 Temperature Measurement, Probe Number = 2, T = 20.075000 C 16:21:28 Temperature Measurement, Probe Number = 3, T = 20.036000 C 16:21:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:21:29 Integrated Voltage Measurement... 16:21:48 Voltage Offset Correction: v_off_ini = 0.000000490 V, v_off_fin = 0.000005352 V 16:21:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175399260 Vs 16:21:49 Integrated Voltage Measurement... 16:22:09 Voltage Offset Correction: v_off_ini = 0.000004211 V, v_off_fin = -0.000002615 V 16:22:09 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175291416 Vs 16:22:11 Temperature Measurement, Probe Number = 0, T = 20.191000 C 16:22:12 Temperature Measurement, Probe Number = 1, T = 20.096000 C 16:22:13 Temperature Measurement, Probe Number = 2, T = 20.073000 C 16:22:13 Temperature Measurement, Probe Number = 3, T = 20.034000 C 16:22:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 16:22:13 Integrated Voltage Measurement... 16:22:33 Voltage Offset Correction: v_off_ini = 0.000000527 V, v_off_fin = 0.000005017 V 16:22:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175382699 Vs 16:22:33 Integrated Voltage Measurement... 16:22:52 Voltage Offset Correction: v_off_ini = 0.000004493 V, v_off_fin = -0.000002828 V 16:22:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291225 Vs 16:22:55 Temperature Measurement, Probe Number = 0, T = 20.165000 C 16:22:55 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:22:56 Temperature Measurement, Probe Number = 2, T = 20.075000 C 16:22:57 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:22:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:22:57 Integrated Voltage Measurement... 16:23:16 Voltage Offset Correction: v_off_ini = 0.000000947 V, v_off_fin = 0.000005699 V 16:23:16 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175399240 Vs 16:23:16 Integrated Voltage Measurement... 16:23:36 Voltage Offset Correction: v_off_ini = 0.000004695 V, v_off_fin = -0.000002335 V 16:23:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175297020 Vs 16:23:39 Temperature Measurement, Probe Number = 0, T = 20.145000 C 16:23:39 Temperature Measurement, Probe Number = 1, T = 20.101000 C 16:23:40 Temperature Measurement, Probe Number = 2, T = 20.077000 C 16:23:40 Temperature Measurement, Probe Number = 3, T = 20.036000 C 16:23:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:23:41 Integrated Voltage Measurement... 16:24:00 Voltage Offset Correction: v_off_ini = 0.000000310 V, v_off_fin = 0.000005893 V 16:24:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401377 Vs 16:24:00 Integrated Voltage Measurement... 16:24:19 Voltage Offset Correction: v_off_ini = 0.000005275 V, v_off_fin = -0.000002127 V 16:24:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175287827 Vs 16:24:22 Temperature Measurement, Probe Number = 0, T = 20.138000 C 16:24:22 Temperature Measurement, Probe Number = 1, T = 20.104000 C 16:24:23 Temperature Measurement, Probe Number = 2, T = 20.080000 C 16:24:24 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:24:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:24:24 Integrated Voltage Measurement... 16:24:43 Voltage Offset Correction: v_off_ini = 0.000000862 V, v_off_fin = 0.000005205 V 16:24:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400177 Vs 16:24:43 Integrated Voltage Measurement... 16:25:03 Voltage Offset Correction: v_off_ini = 0.000004356 V, v_off_fin = -0.000001968 V 16:25:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293941 Vs 16:25:06 Temperature Measurement, Probe Number = 0, T = 20.115000 C 16:25:07 Temperature Measurement, Probe Number = 1, T = 20.101000 C 16:25:07 Temperature Measurement, Probe Number = 2, T = 20.078000 C 16:25:08 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:25:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:25:08 Integrated Voltage Measurement... 16:25:27 Voltage Offset Correction: v_off_ini = 0.000000089 V, v_off_fin = 0.000005664 V 16:25:27 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175387420 Vs 16:25:27 Integrated Voltage Measurement... 16:25:47 Voltage Offset Correction: v_off_ini = 0.000004794 V, v_off_fin = -0.000002854 V 16:25:47 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175291345 Vs 16:25:49 Temperature Measurement, Probe Number = 0, T = 20.141000 C 16:25:50 Temperature Measurement, Probe Number = 1, T = 20.101000 C 16:25:51 Temperature Measurement, Probe Number = 2, T = 20.075000 C 16:25:51 Temperature Measurement, Probe Number = 3, T = 20.036000 C 16:25:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:25:51 Integrated Voltage Measurement... 16:26:11 Voltage Offset Correction: v_off_ini = 0.000001268 V, v_off_fin = 0.000005086 V 16:26:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406044 Vs 16:26:12 Integrated Voltage Measurement... 16:26:31 Voltage Offset Correction: v_off_ini = 0.000004450 V, v_off_fin = -0.000002993 V 16:26:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286657 Vs 16:26:33 Temperature Measurement, Probe Number = 0, T = 20.143000 C 16:26:34 Temperature Measurement, Probe Number = 1, T = 20.102000 C 16:26:35 Temperature Measurement, Probe Number = 2, T = 20.075000 C 16:26:35 Temperature Measurement, Probe Number = 3, T = 20.035000 C 16:26:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 16:26:36 Integrated Voltage Measurement... 16:26:55 Voltage Offset Correction: v_off_ini = 0.000001095 V, v_off_fin = 0.000006261 V 16:26:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409329 Vs 16:26:55 Integrated Voltage Measurement... 16:27:14 Voltage Offset Correction: v_off_ini = 0.000004884 V, v_off_fin = -0.000002495 V 16:27:14 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175287227 Vs 16:57:17 Temperature Measurement, Probe Number = 0, T = 20.305000 C 16:57:18 Temperature Measurement, Probe Number = 1, T = 20.106000 C 16:57:18 Temperature Measurement, Probe Number = 2, T = 20.078000 C 16:57:19 Temperature Measurement, Probe Number = 3, T = 20.042000 C 16:57:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:57:19 Integrated Voltage Measurement... 16:57:38 Voltage Offset Correction: v_off_ini = 0.000003039 V, v_off_fin = 0.000005488 V 16:57:39 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175487852 Vs 16:57:39 Integrated Voltage Measurement... 16:57:58 Voltage Offset Correction: v_off_ini = 0.000004804 V, v_off_fin = -0.000002029 V 16:57:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293245 Vs 16:58:01 Temperature Measurement, Probe Number = 0, T = 20.306000 C 16:58:02 Temperature Measurement, Probe Number = 1, T = 20.107000 C 16:58:02 Temperature Measurement, Probe Number = 2, T = 20.079000 C 16:58:03 Temperature Measurement, Probe Number = 3, T = 20.044000 C 16:58:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:58:03 Integrated Voltage Measurement... 16:58:22 Voltage Offset Correction: v_off_ini = 0.000001061 V, v_off_fin = 0.000005587 V 16:58:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175398167 Vs 16:58:23 Integrated Voltage Measurement... 16:58:42 Voltage Offset Correction: v_off_ini = 0.000004536 V, v_off_fin = -0.000002634 V 16:58:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303198 Vs 16:58:45 Temperature Measurement, Probe Number = 0, T = 20.323000 C 16:58:46 Temperature Measurement, Probe Number = 1, T = 20.105000 C 16:58:46 Temperature Measurement, Probe Number = 2, T = 20.080000 C 16:58:47 Temperature Measurement, Probe Number = 3, T = 20.040000 C 16:58:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:58:47 Integrated Voltage Measurement... 16:59:06 Voltage Offset Correction: v_off_ini = 0.000001237 V, v_off_fin = 0.000005399 V 16:59:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401432 Vs 16:59:06 Integrated Voltage Measurement... 16:59:26 Voltage Offset Correction: v_off_ini = 0.000004683 V, v_off_fin = -0.000002707 V 16:59:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294909 Vs 16:59:28 Temperature Measurement, Probe Number = 0, T = 20.308000 C 16:59:29 Temperature Measurement, Probe Number = 1, T = 20.103000 C 16:59:30 Temperature Measurement, Probe Number = 2, T = 20.080000 C 16:59:30 Temperature Measurement, Probe Number = 3, T = 20.042000 C 16:59:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 16:59:31 Integrated Voltage Measurement... 16:59:50 Voltage Offset Correction: v_off_ini = 0.000000515 V, v_off_fin = 0.000005623 V 16:59:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175402959 Vs 16:59:50 Integrated Voltage Measurement... 17:00:09 Voltage Offset Correction: v_off_ini = 0.000004633 V, v_off_fin = -0.000001737 V 17:00:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296555 Vs 17:00:12 Temperature Measurement, Probe Number = 0, T = 20.305000 C 17:00:13 Temperature Measurement, Probe Number = 1, T = 20.106000 C 17:00:13 Temperature Measurement, Probe Number = 2, T = 20.082000 C 17:00:14 Temperature Measurement, Probe Number = 3, T = 20.043000 C 17:00:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:00:14 Integrated Voltage Measurement... 17:00:34 Voltage Offset Correction: v_off_ini = 0.000000439 V, v_off_fin = 0.000005186 V 17:00:34 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175402089 Vs 17:00:34 Integrated Voltage Measurement... 17:00:54 Voltage Offset Correction: v_off_ini = 0.000004531 V, v_off_fin = -0.000003106 V 17:00:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299823 Vs 17:00:56 Temperature Measurement, Probe Number = 0, T = 20.307000 C 17:00:57 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:00:58 Temperature Measurement, Probe Number = 2, T = 20.079000 C 17:00:58 Temperature Measurement, Probe Number = 3, T = 20.039000 C 17:00:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:00:59 Integrated Voltage Measurement... 17:01:18 Voltage Offset Correction: v_off_ini = 0.000000876 V, v_off_fin = 0.000005223 V 17:01:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400877 Vs 17:01:18 Integrated Voltage Measurement... 17:01:37 Voltage Offset Correction: v_off_ini = 0.000004458 V, v_off_fin = -0.000002167 V 17:01:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304739 Vs 17:01:40 Temperature Measurement, Probe Number = 0, T = 20.269000 C 17:01:41 Temperature Measurement, Probe Number = 1, T = 20.106000 C 17:01:41 Temperature Measurement, Probe Number = 2, T = 20.079000 C 17:01:42 Temperature Measurement, Probe Number = 3, T = 20.038000 C 17:01:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:01:42 Integrated Voltage Measurement... 17:02:02 Voltage Offset Correction: v_off_ini = 0.000001195 V, v_off_fin = 0.000005237 V 17:02:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407218 Vs 17:02:02 Integrated Voltage Measurement... 17:02:21 Voltage Offset Correction: v_off_ini = 0.000004286 V, v_off_fin = -0.000003110 V 17:02:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312224 Vs 17:02:24 Temperature Measurement, Probe Number = 0, T = 20.308000 C 17:02:25 Temperature Measurement, Probe Number = 1, T = 20.109000 C 17:02:25 Temperature Measurement, Probe Number = 2, T = 20.080000 C 17:02:26 Temperature Measurement, Probe Number = 3, T = 20.042000 C 17:02:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:02:26 Integrated Voltage Measurement... 17:02:45 Voltage Offset Correction: v_off_ini = 0.000000876 V, v_off_fin = 0.000005292 V 17:02:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401421 Vs 17:02:46 Integrated Voltage Measurement... 17:03:05 Voltage Offset Correction: v_off_ini = 0.000004088 V, v_off_fin = -0.000002841 V 17:03:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300849 Vs 17:03:08 Temperature Measurement, Probe Number = 0, T = 20.305000 C 17:03:08 Temperature Measurement, Probe Number = 1, T = 20.106000 C 17:03:09 Temperature Measurement, Probe Number = 2, T = 20.081000 C 17:03:10 Temperature Measurement, Probe Number = 3, T = 20.043000 C 17:03:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:03:10 Integrated Voltage Measurement... 17:03:29 Voltage Offset Correction: v_off_ini = 0.000000190 V, v_off_fin = 0.000004912 V 17:03:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175398848 Vs 17:03:29 Integrated Voltage Measurement... 17:03:49 Voltage Offset Correction: v_off_ini = 0.000003944 V, v_off_fin = -0.000002921 V 17:03:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306159 Vs 17:03:52 Temperature Measurement, Probe Number = 0, T = 20.267000 C 17:03:52 Temperature Measurement, Probe Number = 1, T = 20.105000 C 17:03:53 Temperature Measurement, Probe Number = 2, T = 20.078000 C 17:03:54 Temperature Measurement, Probe Number = 3, T = 20.041000 C 17:03:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:03:54 Integrated Voltage Measurement... 17:04:13 Voltage Offset Correction: v_off_ini = 0.000000732 V, v_off_fin = 0.000005424 V 17:04:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175399750 Vs 17:04:13 Integrated Voltage Measurement... 17:04:33 Voltage Offset Correction: v_off_ini = 0.000004739 V, v_off_fin = -0.000002533 V 17:04:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296845 Vs 17:34:36 Temperature Measurement, Probe Number = 0, T = 20.244000 C 17:34:36 Temperature Measurement, Probe Number = 1, T = 20.102000 C 17:34:37 Temperature Measurement, Probe Number = 2, T = 20.072000 C 17:34:38 Temperature Measurement, Probe Number = 3, T = 20.037000 C 17:34:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 17:34:38 Integrated Voltage Measurement... 17:34:57 Voltage Offset Correction: v_off_ini = 0.000003180 V, v_off_fin = 0.000005795 V 17:34:57 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175496017 Vs 17:34:57 Integrated Voltage Measurement... 17:35:17 Voltage Offset Correction: v_off_ini = 0.000005040 V, v_off_fin = -0.000001861 V 17:35:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303657 Vs 17:35:20 Temperature Measurement, Probe Number = 0, T = 20.273000 C 17:35:20 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:35:21 Temperature Measurement, Probe Number = 2, T = 20.075000 C 17:35:21 Temperature Measurement, Probe Number = 3, T = 20.041000 C 17:35:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 17:35:22 Integrated Voltage Measurement... 17:35:41 Voltage Offset Correction: v_off_ini = 0.000000875 V, v_off_fin = 0.000005320 V 17:35:41 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175403332 Vs 17:35:41 Integrated Voltage Measurement... 17:36:00 Voltage Offset Correction: v_off_ini = 0.000004581 V, v_off_fin = -0.000002911 V 17:36:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304942 Vs 17:36:03 Temperature Measurement, Probe Number = 0, T = 20.263000 C 17:36:04 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:36:05 Temperature Measurement, Probe Number = 2, T = 20.081000 C 17:36:05 Temperature Measurement, Probe Number = 3, T = 20.044000 C 17:36:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:36:05 Integrated Voltage Measurement... 17:36:25 Voltage Offset Correction: v_off_ini = 0.000000173 V, v_off_fin = 0.000005087 V 17:36:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411239 Vs 17:36:26 Integrated Voltage Measurement... 17:36:45 Voltage Offset Correction: v_off_ini = 0.000004138 V, v_off_fin = -0.000003150 V 17:36:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301272 Vs 17:36:48 Temperature Measurement, Probe Number = 0, T = 20.224000 C 17:36:49 Temperature Measurement, Probe Number = 1, T = 20.105000 C 17:36:49 Temperature Measurement, Probe Number = 2, T = 20.080000 C 17:36:50 Temperature Measurement, Probe Number = 3, T = 20.044000 C 17:36:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:36:50 Integrated Voltage Measurement... 17:37:09 Voltage Offset Correction: v_off_ini = 0.000000670 V, v_off_fin = 0.000005264 V 17:37:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408625 Vs 17:37:09 Integrated Voltage Measurement... 17:37:29 Voltage Offset Correction: v_off_ini = 0.000004888 V, v_off_fin = -0.000001952 V 17:37:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305473 Vs 17:37:31 Temperature Measurement, Probe Number = 0, T = 20.196000 C 17:37:32 Temperature Measurement, Probe Number = 1, T = 20.103000 C 17:37:33 Temperature Measurement, Probe Number = 2, T = 20.077000 C 17:37:33 Temperature Measurement, Probe Number = 3, T = 20.040000 C 17:37:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:37:34 Integrated Voltage Measurement... 17:37:53 Voltage Offset Correction: v_off_ini = 0.000000779 V, v_off_fin = 0.000005198 V 17:37:53 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408286 Vs 17:37:53 Integrated Voltage Measurement... 17:38:13 Voltage Offset Correction: v_off_ini = 0.000004379 V, v_off_fin = -0.000003065 V 17:38:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314189 Vs 17:38:16 Temperature Measurement, Probe Number = 0, T = 20.183000 C 17:38:16 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:38:17 Temperature Measurement, Probe Number = 2, T = 20.080000 C 17:38:18 Temperature Measurement, Probe Number = 3, T = 20.042000 C 17:38:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:38:18 Integrated Voltage Measurement... 17:38:37 Voltage Offset Correction: v_off_ini = -0.000000144 V, v_off_fin = 0.000004811 V 17:38:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406769 Vs 17:38:37 Integrated Voltage Measurement... 17:38:57 Voltage Offset Correction: v_off_ini = 0.000003975 V, v_off_fin = -0.000003618 V 17:38:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309293 Vs 17:38:59 Temperature Measurement, Probe Number = 0, T = 20.174000 C 17:39:00 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:39:01 Temperature Measurement, Probe Number = 2, T = 20.079000 C 17:39:01 Temperature Measurement, Probe Number = 3, T = 20.041000 C 17:39:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:39:02 Integrated Voltage Measurement... 17:39:21 Voltage Offset Correction: v_off_ini = -0.000000342 V, v_off_fin = 0.000005062 V 17:39:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412797 Vs 17:39:21 Integrated Voltage Measurement... 17:39:41 Voltage Offset Correction: v_off_ini = 0.000004160 V, v_off_fin = -0.000002500 V 17:39:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320185 Vs 17:39:44 Temperature Measurement, Probe Number = 0, T = 20.216000 C 17:39:45 Temperature Measurement, Probe Number = 1, T = 20.105000 C 17:39:45 Temperature Measurement, Probe Number = 2, T = 20.076000 C 17:39:46 Temperature Measurement, Probe Number = 3, T = 20.041000 C 17:39:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:39:46 Integrated Voltage Measurement... 17:40:05 Voltage Offset Correction: v_off_ini = 0.000000538 V, v_off_fin = 0.000005166 V 17:40:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404291 Vs 17:40:05 Integrated Voltage Measurement... 17:40:24 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = -0.000002778 V 17:40:25 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175303958 Vs 17:40:27 Temperature Measurement, Probe Number = 0, T = 20.183000 C 17:40:28 Temperature Measurement, Probe Number = 1, T = 20.104000 C 17:40:29 Temperature Measurement, Probe Number = 2, T = 20.072000 C 17:40:29 Temperature Measurement, Probe Number = 3, T = 20.040000 C 17:40:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 17:40:29 Integrated Voltage Measurement... 17:40:48 Voltage Offset Correction: v_off_ini = 0.000000681 V, v_off_fin = 0.000004725 V 17:40:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410950 Vs 17:40:49 Integrated Voltage Measurement... 17:41:08 Voltage Offset Correction: v_off_ini = 0.000004116 V, v_off_fin = -0.000002813 V 17:41:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314321 Vs 17:41:11 Temperature Measurement, Probe Number = 0, T = 20.122000 C 17:41:12 Temperature Measurement, Probe Number = 1, T = 20.101000 C 17:41:12 Temperature Measurement, Probe Number = 2, T = 20.076000 C 17:41:13 Temperature Measurement, Probe Number = 3, T = 20.036000 C 17:41:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 17:41:13 Integrated Voltage Measurement... 17:41:32 Voltage Offset Correction: v_off_ini = 0.000000065 V, v_off_fin = 0.000004438 V 17:41:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403105 Vs 17:41:32 Integrated Voltage Measurement... 17:41:52 Voltage Offset Correction: v_off_ini = 0.000003789 V, v_off_fin = -0.000002946 V 17:41:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175313846 Vs 18:11:54 Temperature Measurement, Probe Number = 0, T = 20.325000 C 18:11:55 Temperature Measurement, Probe Number = 1, T = 20.104000 C 18:11:56 Temperature Measurement, Probe Number = 2, T = 20.080000 C 18:11:56 Temperature Measurement, Probe Number = 3, T = 20.043000 C 18:11:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:11:56 Integrated Voltage Measurement... 18:12:16 Voltage Offset Correction: v_off_ini = 0.000002425 V, v_off_fin = 0.000004640 V 18:12:16 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175494828 Vs 18:12:16 Integrated Voltage Measurement... 18:12:35 Voltage Offset Correction: v_off_ini = 0.000003645 V, v_off_fin = -0.000003276 V 18:12:35 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314212 Vs 18:12:38 Temperature Measurement, Probe Number = 0, T = 20.288000 C 18:12:39 Temperature Measurement, Probe Number = 1, T = 20.105000 C 18:12:39 Temperature Measurement, Probe Number = 2, T = 20.080000 C 18:12:40 Temperature Measurement, Probe Number = 3, T = 20.047000 C 18:12:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:12:40 Integrated Voltage Measurement... 18:12:59 Voltage Offset Correction: v_off_ini = 0.000000579 V, v_off_fin = 0.000005439 V 18:12:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415540 Vs 18:13:00 Integrated Voltage Measurement... 18:13:19 Voltage Offset Correction: v_off_ini = 0.000004091 V, v_off_fin = -0.000003439 V 18:13:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313793 Vs 18:13:22 Temperature Measurement, Probe Number = 0, T = 20.239000 C 18:13:22 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:13:23 Temperature Measurement, Probe Number = 2, T = 20.078000 C 18:13:24 Temperature Measurement, Probe Number = 3, T = 20.044000 C 18:13:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:13:24 Integrated Voltage Measurement... 18:13:43 Voltage Offset Correction: v_off_ini = 0.000000216 V, v_off_fin = 0.000004892 V 18:13:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411179 Vs 18:13:43 Integrated Voltage Measurement... 18:14:02 Voltage Offset Correction: v_off_ini = 0.000004177 V, v_off_fin = -0.000002786 V 18:14:02 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175313116 Vs 18:14:05 Temperature Measurement, Probe Number = 0, T = 20.233000 C 18:14:06 Temperature Measurement, Probe Number = 1, T = 20.103000 C 18:14:06 Temperature Measurement, Probe Number = 2, T = 20.078000 C 18:14:07 Temperature Measurement, Probe Number = 3, T = 20.040000 C 18:14:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:14:07 Integrated Voltage Measurement... 18:14:26 Voltage Offset Correction: v_off_ini = 0.000000450 V, v_off_fin = 0.000005296 V 18:14:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415067 Vs 18:14:27 Integrated Voltage Measurement... 18:14:46 Voltage Offset Correction: v_off_ini = 0.000004443 V, v_off_fin = -0.000002488 V 18:14:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317323 Vs 18:14:49 Temperature Measurement, Probe Number = 0, T = 20.190000 C 18:14:49 Temperature Measurement, Probe Number = 1, T = 20.105000 C 18:14:50 Temperature Measurement, Probe Number = 2, T = 20.079000 C 18:14:51 Temperature Measurement, Probe Number = 3, T = 20.042000 C 18:14:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:14:51 Integrated Voltage Measurement... 18:15:10 Voltage Offset Correction: v_off_ini = 0.000000533 V, v_off_fin = 0.000004696 V 18:15:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409463 Vs 18:15:11 Integrated Voltage Measurement... 18:15:30 Voltage Offset Correction: v_off_ini = 0.000004255 V, v_off_fin = -0.000002930 V 18:15:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314501 Vs 18:15:32 Temperature Measurement, Probe Number = 0, T = 20.180000 C 18:15:33 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:15:34 Temperature Measurement, Probe Number = 2, T = 20.074000 C 18:15:34 Temperature Measurement, Probe Number = 3, T = 20.037000 C 18:15:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:15:35 Integrated Voltage Measurement... 18:15:54 Voltage Offset Correction: v_off_ini = 0.000000926 V, v_off_fin = 0.000005528 V 18:15:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175418596 Vs 18:15:54 Integrated Voltage Measurement... 18:16:13 Voltage Offset Correction: v_off_ini = 0.000004423 V, v_off_fin = -0.000002918 V 18:16:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316638 Vs 18:16:16 Temperature Measurement, Probe Number = 0, T = 20.226000 C 18:16:17 Temperature Measurement, Probe Number = 1, T = 20.103000 C 18:16:17 Temperature Measurement, Probe Number = 2, T = 20.081000 C 18:16:18 Temperature Measurement, Probe Number = 3, T = 20.037000 C 18:16:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:16:18 Integrated Voltage Measurement... 18:16:37 Voltage Offset Correction: v_off_ini = 0.000000408 V, v_off_fin = 0.000005195 V 18:16:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413314 Vs 18:16:37 Integrated Voltage Measurement... 18:16:56 Voltage Offset Correction: v_off_ini = 0.000004620 V, v_off_fin = -0.000002725 V 18:16:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319691 Vs 18:16:59 Temperature Measurement, Probe Number = 0, T = 20.219000 C 18:17:00 Temperature Measurement, Probe Number = 1, T = 20.098000 C 18:17:01 Temperature Measurement, Probe Number = 2, T = 20.073000 C 18:17:01 Temperature Measurement, Probe Number = 3, T = 20.035000 C 18:17:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:17:01 Integrated Voltage Measurement... 18:17:21 Voltage Offset Correction: v_off_ini = 0.000000349 V, v_off_fin = 0.000005398 V 18:17:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426788 Vs 18:17:21 Integrated Voltage Measurement... 18:17:40 Voltage Offset Correction: v_off_ini = 0.000004535 V, v_off_fin = -0.000003307 V 18:17:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318959 Vs 18:17:43 Temperature Measurement, Probe Number = 0, T = 20.180000 C 18:17:44 Temperature Measurement, Probe Number = 1, T = 20.100000 C 18:17:44 Temperature Measurement, Probe Number = 2, T = 20.072000 C 18:17:45 Temperature Measurement, Probe Number = 3, T = 20.038000 C 18:17:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:17:45 Integrated Voltage Measurement... 18:18:05 Voltage Offset Correction: v_off_ini = 0.000000338 V, v_off_fin = 0.000005270 V 18:18:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417751 Vs 18:18:05 Integrated Voltage Measurement... 18:18:24 Voltage Offset Correction: v_off_ini = 0.000004085 V, v_off_fin = -0.000003163 V 18:18:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175316035 Vs 18:18:27 Temperature Measurement, Probe Number = 0, T = 20.189000 C 18:18:27 Temperature Measurement, Probe Number = 1, T = 20.099000 C 18:18:28 Temperature Measurement, Probe Number = 2, T = 20.074000 C 18:18:29 Temperature Measurement, Probe Number = 3, T = 20.040000 C 18:18:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:18:29 Integrated Voltage Measurement... 18:18:48 Voltage Offset Correction: v_off_ini = 0.000000279 V, v_off_fin = 0.000005990 V 18:18:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175418915 Vs 18:18:48 Integrated Voltage Measurement... 18:19:07 Voltage Offset Correction: v_off_ini = 0.000004859 V, v_off_fin = -0.000003084 V 18:19:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317346 Vs 18:49:10 Temperature Measurement, Probe Number = 0, T = 20.324000 C 18:49:11 Temperature Measurement, Probe Number = 1, T = 20.101000 C 18:49:12 Temperature Measurement, Probe Number = 2, T = 20.076000 C 18:49:12 Temperature Measurement, Probe Number = 3, T = 20.040000 C 18:49:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:49:12 Integrated Voltage Measurement... 18:49:32 Voltage Offset Correction: v_off_ini = 0.000002743 V, v_off_fin = 0.000005283 V 18:49:32 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175506677 Vs 18:49:32 Integrated Voltage Measurement... 18:49:51 Voltage Offset Correction: v_off_ini = 0.000004034 V, v_off_fin = -0.000003246 V 18:49:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316715 Vs 18:49:54 Temperature Measurement, Probe Number = 0, T = 20.366000 C 18:49:54 Temperature Measurement, Probe Number = 1, T = 20.105000 C 18:49:55 Temperature Measurement, Probe Number = 2, T = 20.079000 C 18:49:56 Temperature Measurement, Probe Number = 3, T = 20.043000 C 18:49:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:49:56 Integrated Voltage Measurement... 18:50:15 Voltage Offset Correction: v_off_ini = 0.000000539 V, v_off_fin = 0.000005083 V 18:50:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419311 Vs 18:50:15 Integrated Voltage Measurement... 18:50:34 Voltage Offset Correction: v_off_ini = 0.000004601 V, v_off_fin = -0.000002463 V 18:50:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323730 Vs 18:50:37 Temperature Measurement, Probe Number = 0, T = 20.329000 C 18:50:38 Temperature Measurement, Probe Number = 1, T = 20.106000 C 18:50:38 Temperature Measurement, Probe Number = 2, T = 20.082000 C 18:50:39 Temperature Measurement, Probe Number = 3, T = 20.046000 C 18:50:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.11 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:50:39 Integrated Voltage Measurement... 18:50:59 Voltage Offset Correction: v_off_ini = 0.000000476 V, v_off_fin = 0.000005310 V 18:50:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421154 Vs 18:50:59 Integrated Voltage Measurement... 18:51:18 Voltage Offset Correction: v_off_ini = 0.000004437 V, v_off_fin = -0.000002886 V 18:51:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317087 Vs 18:51:21 Temperature Measurement, Probe Number = 0, T = 20.334000 C 18:51:21 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:51:22 Temperature Measurement, Probe Number = 2, T = 20.081000 C 18:51:23 Temperature Measurement, Probe Number = 3, T = 20.044000 C 18:51:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 18:51:23 Integrated Voltage Measurement... 18:51:42 Voltage Offset Correction: v_off_ini = 0.000000514 V, v_off_fin = 0.000005227 V 18:51:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421810 Vs 18:51:42 Integrated Voltage Measurement... 18:52:01 Voltage Offset Correction: v_off_ini = 0.000004337 V, v_off_fin = -0.000002891 V 18:52:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175328188 Vs 18:52:04 Temperature Measurement, Probe Number = 0, T = 20.348000 C 18:52:05 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:52:06 Temperature Measurement, Probe Number = 2, T = 20.078000 C 18:52:06 Temperature Measurement, Probe Number = 3, T = 20.046000 C 18:52:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.05 18:52:06 Integrated Voltage Measurement... 18:52:25 Voltage Offset Correction: v_off_ini = 0.000000811 V, v_off_fin = 0.000005275 V 18:52:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420098 Vs 18:52:26 Integrated Voltage Measurement... 18:52:45 Voltage Offset Correction: v_off_ini = 0.000005203 V, v_off_fin = -0.000002553 V 18:52:45 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175321042 Vs 18:52:48 Temperature Measurement, Probe Number = 0, T = 20.322000 C 18:52:49 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:52:49 Temperature Measurement, Probe Number = 2, T = 20.075000 C 18:52:50 Temperature Measurement, Probe Number = 3, T = 20.042000 C 18:52:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:52:50 Integrated Voltage Measurement... 18:53:09 Voltage Offset Correction: v_off_ini = 0.000000820 V, v_off_fin = 0.000005579 V 18:53:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427094 Vs 18:53:09 Integrated Voltage Measurement... 18:53:29 Voltage Offset Correction: v_off_ini = 0.000004462 V, v_off_fin = -0.000003200 V 18:53:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324928 Vs 18:53:31 Temperature Measurement, Probe Number = 0, T = 20.287000 C 18:53:32 Temperature Measurement, Probe Number = 1, T = 20.100000 C 18:53:33 Temperature Measurement, Probe Number = 2, T = 20.072000 C 18:53:33 Temperature Measurement, Probe Number = 3, T = 20.041000 C 18:53:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:53:34 Integrated Voltage Measurement... 18:53:53 Voltage Offset Correction: v_off_ini = 0.000000373 V, v_off_fin = 0.000004952 V 18:53:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420861 Vs 18:53:53 Integrated Voltage Measurement... 18:54:13 Voltage Offset Correction: v_off_ini = 0.000004421 V, v_off_fin = -0.000002247 V 18:54:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326300 Vs 18:54:16 Temperature Measurement, Probe Number = 0, T = 20.239000 C 18:54:16 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:54:17 Temperature Measurement, Probe Number = 2, T = 20.073000 C 18:54:18 Temperature Measurement, Probe Number = 3, T = 20.042000 C 18:54:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:54:18 Integrated Voltage Measurement... 18:54:37 Voltage Offset Correction: v_off_ini = 0.000000302 V, v_off_fin = 0.000005633 V 18:54:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175424746 Vs 18:54:37 Integrated Voltage Measurement... 18:54:57 Voltage Offset Correction: v_off_ini = 0.000005041 V, v_off_fin = -0.000002001 V 18:54:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320571 Vs 18:55:00 Temperature Measurement, Probe Number = 0, T = 20.235000 C 18:55:00 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:55:01 Temperature Measurement, Probe Number = 2, T = 20.074000 C 18:55:02 Temperature Measurement, Probe Number = 3, T = 20.041000 C 18:55:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:55:02 Integrated Voltage Measurement... 18:55:21 Voltage Offset Correction: v_off_ini = 0.000001174 V, v_off_fin = 0.000005679 V 18:55:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421932 Vs 18:55:21 Integrated Voltage Measurement... 18:55:40 Voltage Offset Correction: v_off_ini = 0.000004296 V, v_off_fin = -0.000003597 V 18:55:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175321894 Vs 18:55:43 Temperature Measurement, Probe Number = 0, T = 20.243000 C 18:55:44 Temperature Measurement, Probe Number = 1, T = 20.102000 C 18:55:44 Temperature Measurement, Probe Number = 2, T = 20.069000 C 18:55:45 Temperature Measurement, Probe Number = 3, T = 20.039000 C 18:55:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 18:55:45 Integrated Voltage Measurement... 18:56:04 Voltage Offset Correction: v_off_ini = -0.000000626 V, v_off_fin = 0.000005712 V 18:56:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422842 Vs 18:56:05 Integrated Voltage Measurement... 18:56:24 Voltage Offset Correction: v_off_ini = 0.000004716 V, v_off_fin = -0.000002722 V 18:56:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322783 Vs 19:26:27 Temperature Measurement, Probe Number = 0, T = 20.233000 C 19:26:28 Temperature Measurement, Probe Number = 1, T = 20.094000 C 19:26:28 Temperature Measurement, Probe Number = 2, T = 20.066000 C 19:26:29 Temperature Measurement, Probe Number = 3, T = 20.038000 C 19:26:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:26:29 Integrated Voltage Measurement... 19:26:49 Voltage Offset Correction: v_off_ini = 0.000002931 V, v_off_fin = 0.000004944 V 19:26:49 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175506396 Vs 19:26:49 Integrated Voltage Measurement... 19:27:08 Voltage Offset Correction: v_off_ini = 0.000004194 V, v_off_fin = -0.000002716 V 19:27:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316930 Vs 19:27:11 Temperature Measurement, Probe Number = 0, T = 20.242000 C 19:27:12 Temperature Measurement, Probe Number = 1, T = 20.093000 C 19:27:12 Temperature Measurement, Probe Number = 2, T = 20.066000 C 19:27:13 Temperature Measurement, Probe Number = 3, T = 20.036000 C 19:27:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:27:13 Integrated Voltage Measurement... 19:27:33 Voltage Offset Correction: v_off_ini = -0.000000158 V, v_off_fin = 0.000006089 V 19:27:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427366 Vs 19:27:33 Integrated Voltage Measurement... 19:27:52 Voltage Offset Correction: v_off_ini = 0.000004756 V, v_off_fin = -0.000002860 V 19:27:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320630 Vs 19:27:55 Temperature Measurement, Probe Number = 0, T = 20.247000 C 19:27:56 Temperature Measurement, Probe Number = 1, T = 20.094000 C 19:27:56 Temperature Measurement, Probe Number = 2, T = 20.070000 C 19:27:57 Temperature Measurement, Probe Number = 3, T = 20.040000 C 19:27:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:27:57 Integrated Voltage Measurement... 19:28:16 Voltage Offset Correction: v_off_ini = 0.000000474 V, v_off_fin = 0.000005574 V 19:28:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426866 Vs 19:28:16 Integrated Voltage Measurement... 19:28:36 Voltage Offset Correction: v_off_ini = 0.000004754 V, v_off_fin = -0.000002478 V 19:28:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323748 Vs 19:28:39 Temperature Measurement, Probe Number = 0, T = 20.289000 C 19:28:39 Temperature Measurement, Probe Number = 1, T = 20.098000 C 19:28:40 Temperature Measurement, Probe Number = 2, T = 20.074000 C 19:28:41 Temperature Measurement, Probe Number = 3, T = 20.039000 C 19:28:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:28:41 Integrated Voltage Measurement... 19:29:00 Voltage Offset Correction: v_off_ini = 0.000000936 V, v_off_fin = 0.000005158 V 19:29:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431984 Vs 19:29:00 Integrated Voltage Measurement... 19:29:20 Voltage Offset Correction: v_off_ini = 0.000004350 V, v_off_fin = -0.000002171 V 19:29:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175326248 Vs 19:29:23 Temperature Measurement, Probe Number = 0, T = 20.261000 C 19:29:24 Temperature Measurement, Probe Number = 1, T = 20.098000 C 19:29:24 Temperature Measurement, Probe Number = 2, T = 20.070000 C 19:29:25 Temperature Measurement, Probe Number = 3, T = 20.038000 C 19:29:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:29:25 Integrated Voltage Measurement... 19:29:45 Voltage Offset Correction: v_off_ini = 0.000000632 V, v_off_fin = 0.000005512 V 19:29:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431988 Vs 19:29:45 Integrated Voltage Measurement... 19:30:04 Voltage Offset Correction: v_off_ini = 0.000004511 V, v_off_fin = -0.000003138 V 19:30:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321515 Vs 19:30:07 Temperature Measurement, Probe Number = 0, T = 20.239000 C 19:30:08 Temperature Measurement, Probe Number = 1, T = 20.096000 C 19:30:09 Temperature Measurement, Probe Number = 2, T = 20.072000 C 19:30:09 Temperature Measurement, Probe Number = 3, T = 20.039000 C 19:30:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:30:09 Integrated Voltage Measurement... 19:30:28 Voltage Offset Correction: v_off_ini = 0.000000755 V, v_off_fin = 0.000005776 V 19:30:29 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175432182 Vs 19:30:29 Integrated Voltage Measurement... 19:30:48 Voltage Offset Correction: v_off_ini = 0.000004862 V, v_off_fin = -0.000002659 V 19:30:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323339 Vs 19:30:51 Temperature Measurement, Probe Number = 0, T = 20.265000 C 19:30:52 Temperature Measurement, Probe Number = 1, T = 20.098000 C 19:30:52 Temperature Measurement, Probe Number = 2, T = 20.072000 C 19:30:53 Temperature Measurement, Probe Number = 3, T = 20.043000 C 19:30:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:30:53 Integrated Voltage Measurement... 19:31:12 Voltage Offset Correction: v_off_ini = 0.000000537 V, v_off_fin = 0.000005423 V 19:31:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425165 Vs 19:31:13 Integrated Voltage Measurement... 19:31:32 Voltage Offset Correction: v_off_ini = 0.000004533 V, v_off_fin = -0.000003418 V 19:31:32 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175326961 Vs 19:31:34 Temperature Measurement, Probe Number = 0, T = 20.289000 C 19:31:35 Temperature Measurement, Probe Number = 1, T = 20.096000 C 19:31:36 Temperature Measurement, Probe Number = 2, T = 20.072000 C 19:31:36 Temperature Measurement, Probe Number = 3, T = 20.038000 C 19:31:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:31:37 Integrated Voltage Measurement... 19:31:56 Voltage Offset Correction: v_off_ini = 0.000000104 V, v_off_fin = 0.000005529 V 19:31:56 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175436002 Vs 19:31:56 Integrated Voltage Measurement... 19:32:16 Voltage Offset Correction: v_off_ini = 0.000004956 V, v_off_fin = -0.000002130 V 19:32:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323692 Vs 19:32:19 Temperature Measurement, Probe Number = 0, T = 20.358000 C 19:32:19 Temperature Measurement, Probe Number = 1, T = 20.099000 C 19:32:20 Temperature Measurement, Probe Number = 2, T = 20.076000 C 19:32:21 Temperature Measurement, Probe Number = 3, T = 20.039000 C 19:32:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.08 P3 = Top 1, Value = 20.04 19:32:21 Integrated Voltage Measurement... 19:32:41 Voltage Offset Correction: v_off_ini = 0.000001213 V, v_off_fin = 0.000005100 V 19:32:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434461 Vs 19:32:41 Integrated Voltage Measurement... 19:33:00 Voltage Offset Correction: v_off_ini = 0.000004563 V, v_off_fin = -0.000002667 V 19:33:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324309 Vs 19:33:03 Temperature Measurement, Probe Number = 0, T = 20.348000 C 19:33:04 Temperature Measurement, Probe Number = 1, T = 20.099000 C 19:33:04 Temperature Measurement, Probe Number = 2, T = 20.073000 C 19:33:05 Temperature Measurement, Probe Number = 3, T = 20.040000 C 19:33:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 19:33:05 Integrated Voltage Measurement... 19:33:25 Voltage Offset Correction: v_off_ini = 0.000000706 V, v_off_fin = 0.000004787 V 19:33:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429816 Vs 19:33:25 Integrated Voltage Measurement... 19:33:44 Voltage Offset Correction: v_off_ini = 0.000004608 V, v_off_fin = -0.000002630 V 19:33:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314029 Vs 20:03:47 Temperature Measurement, Probe Number = 0, T = 20.275000 C 20:03:48 Temperature Measurement, Probe Number = 1, T = 20.095000 C 20:03:48 Temperature Measurement, Probe Number = 2, T = 20.066000 C 20:03:49 Temperature Measurement, Probe Number = 3, T = 20.036000 C 20:03:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:03:49 Integrated Voltage Measurement... 20:04:08 Voltage Offset Correction: v_off_ini = 0.000002349 V, v_off_fin = 0.000005439 V 20:04:09 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175516127 Vs 20:04:09 Integrated Voltage Measurement... 20:04:28 Voltage Offset Correction: v_off_ini = 0.000004402 V, v_off_fin = -0.000002855 V 20:04:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175329944 Vs 20:04:31 Temperature Measurement, Probe Number = 0, T = 20.288000 C 20:04:32 Temperature Measurement, Probe Number = 1, T = 20.096000 C 20:04:32 Temperature Measurement, Probe Number = 2, T = 20.066000 C 20:04:33 Temperature Measurement, Probe Number = 3, T = 20.038000 C 20:04:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:04:33 Integrated Voltage Measurement... 20:04:52 Voltage Offset Correction: v_off_ini = 0.000001036 V, v_off_fin = 0.000005690 V 20:04:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426297 Vs 20:04:53 Integrated Voltage Measurement... 20:05:11 Voltage Offset Correction: v_off_ini = 0.000004955 V, v_off_fin = -0.000002461 V 20:05:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316228 Vs 20:05:14 Temperature Measurement, Probe Number = 0, T = 20.299000 C 20:05:15 Temperature Measurement, Probe Number = 1, T = 20.094000 C 20:05:16 Temperature Measurement, Probe Number = 2, T = 20.067000 C 20:05:16 Temperature Measurement, Probe Number = 3, T = 20.033000 C 20:05:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.03 20:05:16 Integrated Voltage Measurement... 20:05:36 Voltage Offset Correction: v_off_ini = 0.000001270 V, v_off_fin = 0.000005242 V 20:05:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428900 Vs 20:05:36 Integrated Voltage Measurement... 20:05:55 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000002942 V 20:05:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325029 Vs 20:05:58 Temperature Measurement, Probe Number = 0, T = 20.366000 C 20:05:59 Temperature Measurement, Probe Number = 1, T = 20.095000 C 20:05:59 Temperature Measurement, Probe Number = 2, T = 20.071000 C 20:06:00 Temperature Measurement, Probe Number = 3, T = 20.037000 C 20:06:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:06:00 Integrated Voltage Measurement... 20:06:20 Voltage Offset Correction: v_off_ini = 0.000000222 V, v_off_fin = 0.000006007 V 20:06:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432111 Vs 20:06:20 Integrated Voltage Measurement... 20:06:39 Voltage Offset Correction: v_off_ini = 0.000005000 V, v_off_fin = -0.000002564 V 20:06:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320816 Vs 20:06:42 Temperature Measurement, Probe Number = 0, T = 20.400000 C 20:06:43 Temperature Measurement, Probe Number = 1, T = 20.096000 C 20:06:44 Temperature Measurement, Probe Number = 2, T = 20.070000 C 20:06:44 Temperature Measurement, Probe Number = 3, T = 20.040000 C 20:06:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:06:44 Integrated Voltage Measurement... 20:07:04 Voltage Offset Correction: v_off_ini = 0.000000945 V, v_off_fin = 0.000005611 V 20:07:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433254 Vs 20:07:04 Integrated Voltage Measurement... 20:07:23 Voltage Offset Correction: v_off_ini = 0.000004633 V, v_off_fin = -0.000002848 V 20:07:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326302 Vs 20:07:26 Temperature Measurement, Probe Number = 0, T = 20.400000 C 20:07:27 Temperature Measurement, Probe Number = 1, T = 20.097000 C 20:07:28 Temperature Measurement, Probe Number = 2, T = 20.070000 C 20:07:28 Temperature Measurement, Probe Number = 3, T = 20.039000 C 20:07:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:07:28 Integrated Voltage Measurement... 20:07:48 Voltage Offset Correction: v_off_ini = 0.000001348 V, v_off_fin = 0.000005646 V 20:07:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433884 Vs 20:07:48 Integrated Voltage Measurement... 20:08:07 Voltage Offset Correction: v_off_ini = 0.000004680 V, v_off_fin = -0.000002064 V 20:08:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320019 Vs 20:08:10 Temperature Measurement, Probe Number = 0, T = 20.441000 C 20:08:11 Temperature Measurement, Probe Number = 1, T = 20.096000 C 20:08:12 Temperature Measurement, Probe Number = 2, T = 20.068000 C 20:08:12 Temperature Measurement, Probe Number = 3, T = 20.037000 C 20:08:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:08:12 Integrated Voltage Measurement... 20:08:31 Voltage Offset Correction: v_off_ini = 0.000001447 V, v_off_fin = 0.000006065 V 20:08:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431787 Vs 20:08:32 Integrated Voltage Measurement... 20:08:51 Voltage Offset Correction: v_off_ini = 0.000004857 V, v_off_fin = -0.000002653 V 20:08:51 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175317563 Vs 20:08:54 Temperature Measurement, Probe Number = 0, T = 20.462000 C 20:08:54 Temperature Measurement, Probe Number = 1, T = 20.097000 C 20:08:55 Temperature Measurement, Probe Number = 2, T = 20.070000 C 20:08:56 Temperature Measurement, Probe Number = 3, T = 20.038000 C 20:08:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:08:56 Integrated Voltage Measurement... 20:09:15 Voltage Offset Correction: v_off_ini = 0.000000666 V, v_off_fin = 0.000005186 V 20:09:15 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175429874 Vs 20:09:15 Integrated Voltage Measurement... 20:09:35 Voltage Offset Correction: v_off_ini = 0.000004443 V, v_off_fin = -0.000002605 V 20:09:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323714 Vs 20:09:37 Temperature Measurement, Probe Number = 0, T = 20.493000 C 20:09:38 Temperature Measurement, Probe Number = 1, T = 20.097000 C 20:09:39 Temperature Measurement, Probe Number = 2, T = 20.067000 C 20:09:39 Temperature Measurement, Probe Number = 3, T = 20.037000 C 20:09:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:09:40 Integrated Voltage Measurement... 20:09:59 Voltage Offset Correction: v_off_ini = 0.000000948 V, v_off_fin = 0.000005248 V 20:09:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426304 Vs 20:09:59 Integrated Voltage Measurement... 20:10:18 Voltage Offset Correction: v_off_ini = 0.000004643 V, v_off_fin = -0.000002193 V 20:10:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323813 Vs 20:10:21 Temperature Measurement, Probe Number = 0, T = 20.451000 C 20:10:22 Temperature Measurement, Probe Number = 1, T = 20.098000 C 20:10:22 Temperature Measurement, Probe Number = 2, T = 20.067000 C 20:10:23 Temperature Measurement, Probe Number = 3, T = 20.039000 C 20:10:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.10 P2 = Bottom 3, Value = 20.07 P3 = Top 1, Value = 20.04 20:10:23 Integrated Voltage Measurement... 20:10:42 Voltage Offset Correction: v_off_ini = 0.000000711 V, v_off_fin = 0.000005370 V 20:10:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431115 Vs 20:10:42 Integrated Voltage Measurement... 20:11:02 Voltage Offset Correction: v_off_ini = 0.000004635 V, v_off_fin = -0.000002537 V 20:11:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322192 Vs 20:41:05 Temperature Measurement, Probe Number = 0, T = 20.252000 C 20:41:05 Temperature Measurement, Probe Number = 1, T = 20.088000 C 20:41:06 Temperature Measurement, Probe Number = 2, T = 20.061000 C 20:41:07 Temperature Measurement, Probe Number = 3, T = 20.035000 C 20:41:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 20:41:07 Integrated Voltage Measurement... 20:41:26 Voltage Offset Correction: v_off_ini = 0.000003696 V, v_off_fin = 0.000006007 V 20:41:26 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175525624 Vs 20:41:26 Integrated Voltage Measurement... 20:41:46 Voltage Offset Correction: v_off_ini = 0.000005465 V, v_off_fin = -0.000001901 V 20:41:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320638 Vs 20:41:48 Temperature Measurement, Probe Number = 0, T = 20.284000 C 20:41:49 Temperature Measurement, Probe Number = 1, T = 20.086000 C 20:41:50 Temperature Measurement, Probe Number = 2, T = 20.057000 C 20:41:50 Temperature Measurement, Probe Number = 3, T = 20.032000 C 20:41:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 20:41:51 Integrated Voltage Measurement... 20:42:10 Voltage Offset Correction: v_off_ini = 0.000002066 V, v_off_fin = 0.000005531 V 20:42:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432722 Vs 20:42:10 Integrated Voltage Measurement... 20:42:31 Voltage Offset Correction: v_off_ini = 0.000004976 V, v_off_fin = -0.000000802 V 20:42:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175325055 Vs 20:42:34 Temperature Measurement, Probe Number = 0, T = 20.265000 C 20:42:35 Temperature Measurement, Probe Number = 1, T = 20.088000 C 20:42:35 Temperature Measurement, Probe Number = 2, T = 20.061000 C 20:42:36 Temperature Measurement, Probe Number = 3, T = 20.035000 C 20:42:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 20:42:36 Integrated Voltage Measurement... 20:42:55 Voltage Offset Correction: v_off_ini = 0.000001535 V, v_off_fin = 0.000005367 V 20:42:55 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417521 Vs 20:42:56 Integrated Voltage Measurement... 20:43:15 Voltage Offset Correction: v_off_ini = 0.000004881 V, v_off_fin = -0.000002757 V 20:43:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322392 Vs 20:43:18 Temperature Measurement, Probe Number = 0, T = 20.325000 C 20:43:18 Temperature Measurement, Probe Number = 1, T = 20.088000 C 20:43:19 Temperature Measurement, Probe Number = 2, T = 20.060000 C 20:43:20 Temperature Measurement, Probe Number = 3, T = 20.036000 C 20:43:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 20:43:20 Integrated Voltage Measurement... 20:43:39 Voltage Offset Correction: v_off_ini = 0.000000741 V, v_off_fin = 0.000005589 V 20:43:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432570 Vs 20:43:39 Integrated Voltage Measurement... 20:43:59 Voltage Offset Correction: v_off_ini = 0.000004381 V, v_off_fin = -0.000002013 V 20:43:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323934 Vs 20:44:02 Temperature Measurement, Probe Number = 0, T = 20.324000 C 20:44:03 Temperature Measurement, Probe Number = 1, T = 20.088000 C 20:44:03 Temperature Measurement, Probe Number = 2, T = 20.061000 C 20:44:04 Temperature Measurement, Probe Number = 3, T = 20.038000 C 20:44:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 20:44:04 Integrated Voltage Measurement... 20:44:24 Voltage Offset Correction: v_off_ini = 0.000000470 V, v_off_fin = 0.000004923 V 20:44:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430391 Vs 20:44:24 Integrated Voltage Measurement... 20:44:43 Voltage Offset Correction: v_off_ini = 0.000004234 V, v_off_fin = -0.000002184 V 20:44:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323039 Vs 20:44:46 Temperature Measurement, Probe Number = 0, T = 20.326000 C 20:44:47 Temperature Measurement, Probe Number = 1, T = 20.092000 C 20:44:47 Temperature Measurement, Probe Number = 2, T = 20.063000 C 20:44:48 Temperature Measurement, Probe Number = 3, T = 20.038000 C 20:44:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.04 20:44:48 Integrated Voltage Measurement... 20:45:07 Voltage Offset Correction: v_off_ini = 0.000000920 V, v_off_fin = 0.000005169 V 20:45:07 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433232 Vs 20:45:08 Integrated Voltage Measurement... 20:45:27 Voltage Offset Correction: v_off_ini = 0.000004575 V, v_off_fin = -0.000002619 V 20:45:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175330633 Vs 20:45:30 Temperature Measurement, Probe Number = 0, T = 20.323000 C 20:45:31 Temperature Measurement, Probe Number = 1, T = 20.089000 C 20:45:31 Temperature Measurement, Probe Number = 2, T = 20.062000 C 20:45:32 Temperature Measurement, Probe Number = 3, T = 20.034000 C 20:45:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 20:45:32 Integrated Voltage Measurement... 20:45:51 Voltage Offset Correction: v_off_ini = 0.000000731 V, v_off_fin = 0.000005861 V 20:45:51 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431490 Vs 20:45:51 Integrated Voltage Measurement... 20:46:10 Voltage Offset Correction: v_off_ini = 0.000004705 V, v_off_fin = -0.000003938 V 20:46:11 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175331631 Vs 20:46:13 Temperature Measurement, Probe Number = 0, T = 20.360000 C 20:46:14 Temperature Measurement, Probe Number = 1, T = 20.087000 C 20:46:15 Temperature Measurement, Probe Number = 2, T = 20.057000 C 20:46:15 Temperature Measurement, Probe Number = 3, T = 20.032000 C 20:46:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 20:46:16 Integrated Voltage Measurement... 20:46:35 Voltage Offset Correction: v_off_ini = 0.000000458 V, v_off_fin = 0.000004985 V 20:46:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435246 Vs 20:46:36 Integrated Voltage Measurement... 20:46:55 Voltage Offset Correction: v_off_ini = 0.000004236 V, v_off_fin = -0.000002728 V 20:46:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175332417 Vs 20:46:58 Temperature Measurement, Probe Number = 0, T = 20.328000 C 20:46:59 Temperature Measurement, Probe Number = 1, T = 20.086000 C 20:46:59 Temperature Measurement, Probe Number = 2, T = 20.057000 C 20:47:00 Temperature Measurement, Probe Number = 3, T = 20.031000 C 20:47:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 20:47:00 Integrated Voltage Measurement... 20:47:19 Voltage Offset Correction: v_off_ini = 0.000000237 V, v_off_fin = 0.000005535 V 20:47:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437109 Vs 20:47:20 Integrated Voltage Measurement... 20:47:39 Voltage Offset Correction: v_off_ini = 0.000004473 V, v_off_fin = -0.000003013 V 20:47:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175335791 Vs 20:47:42 Temperature Measurement, Probe Number = 0, T = 20.253000 C 20:47:43 Temperature Measurement, Probe Number = 1, T = 20.090000 C 20:47:43 Temperature Measurement, Probe Number = 2, T = 20.057000 C 20:47:44 Temperature Measurement, Probe Number = 3, T = 20.032000 C 20:47:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 20:47:44 Integrated Voltage Measurement... 20:48:03 Voltage Offset Correction: v_off_ini = 0.000000981 V, v_off_fin = 0.000005318 V 20:48:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433941 Vs 20:48:04 Integrated Voltage Measurement... 20:48:23 Voltage Offset Correction: v_off_ini = 0.000004932 V, v_off_fin = -0.000002875 V 20:48:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175334184 Vs 21:18:26 Temperature Measurement, Probe Number = 0, T = 20.233000 C 21:18:26 Temperature Measurement, Probe Number = 1, T = 20.082000 C 21:18:27 Temperature Measurement, Probe Number = 2, T = 20.053000 C 21:18:28 Temperature Measurement, Probe Number = 3, T = 20.028000 C 21:18:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:18:28 Integrated Voltage Measurement... 21:18:47 Voltage Offset Correction: v_off_ini = 0.000002795 V, v_off_fin = 0.000005904 V 21:18:47 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175525048 Vs 21:18:47 Integrated Voltage Measurement... 21:19:06 Voltage Offset Correction: v_off_ini = 0.000004715 V, v_off_fin = -0.000002529 V 21:19:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319878 Vs 21:19:09 Temperature Measurement, Probe Number = 0, T = 20.306000 C 21:19:10 Temperature Measurement, Probe Number = 1, T = 20.083000 C 21:19:11 Temperature Measurement, Probe Number = 2, T = 20.058000 C 21:19:11 Temperature Measurement, Probe Number = 3, T = 20.026000 C 21:19:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:19:11 Integrated Voltage Measurement... 21:19:31 Voltage Offset Correction: v_off_ini = 0.000000933 V, v_off_fin = 0.000005612 V 21:19:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438371 Vs 21:19:32 Integrated Voltage Measurement... 21:19:51 Voltage Offset Correction: v_off_ini = 0.000004829 V, v_off_fin = -0.000002334 V 21:19:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317137 Vs 21:19:54 Temperature Measurement, Probe Number = 0, T = 20.297000 C 21:19:54 Temperature Measurement, Probe Number = 1, T = 20.087000 C 21:19:55 Temperature Measurement, Probe Number = 2, T = 20.061000 C 21:19:56 Temperature Measurement, Probe Number = 3, T = 20.029000 C 21:19:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:19:56 Integrated Voltage Measurement... 21:20:15 Voltage Offset Correction: v_off_ini = 0.000001626 V, v_off_fin = 0.000006243 V 21:20:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445565 Vs 21:20:15 Integrated Voltage Measurement... 21:20:35 Voltage Offset Correction: v_off_ini = 0.000005311 V, v_off_fin = -0.000001807 V 21:20:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316949 Vs 21:20:37 Temperature Measurement, Probe Number = 0, T = 20.272000 C 21:20:38 Temperature Measurement, Probe Number = 1, T = 20.083000 C 21:20:39 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:20:39 Temperature Measurement, Probe Number = 3, T = 20.026000 C 21:20:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:20:40 Integrated Voltage Measurement... 21:20:59 Voltage Offset Correction: v_off_ini = 0.000001514 V, v_off_fin = 0.000006250 V 21:20:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442442 Vs 21:20:59 Integrated Voltage Measurement... 21:21:18 Voltage Offset Correction: v_off_ini = 0.000005051 V, v_off_fin = -0.000002905 V 21:21:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322822 Vs 21:21:21 Temperature Measurement, Probe Number = 0, T = 20.272000 C 21:21:22 Temperature Measurement, Probe Number = 1, T = 20.078000 C 21:21:22 Temperature Measurement, Probe Number = 2, T = 20.054000 C 21:21:23 Temperature Measurement, Probe Number = 3, T = 20.024000 C 21:21:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:21:23 Integrated Voltage Measurement... 21:21:43 Voltage Offset Correction: v_off_ini = 0.000001263 V, v_off_fin = 0.000006042 V 21:21:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441029 Vs 21:21:43 Integrated Voltage Measurement... 21:22:02 Voltage Offset Correction: v_off_ini = 0.000005020 V, v_off_fin = -0.000002246 V 21:22:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175330879 Vs 21:22:05 Temperature Measurement, Probe Number = 0, T = 20.242000 C 21:22:06 Temperature Measurement, Probe Number = 1, T = 20.083000 C 21:22:06 Temperature Measurement, Probe Number = 2, T = 20.058000 C 21:22:07 Temperature Measurement, Probe Number = 3, T = 20.024000 C 21:22:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.02 21:22:07 Integrated Voltage Measurement... 21:22:26 Voltage Offset Correction: v_off_ini = 0.000000599 V, v_off_fin = 0.000005955 V 21:22:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440643 Vs 21:22:27 Integrated Voltage Measurement... 21:22:46 Voltage Offset Correction: v_off_ini = 0.000005355 V, v_off_fin = -0.000002564 V 21:22:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322275 Vs 21:22:48 Temperature Measurement, Probe Number = 0, T = 20.266000 C 21:22:49 Temperature Measurement, Probe Number = 1, T = 20.084000 C 21:22:50 Temperature Measurement, Probe Number = 2, T = 20.057000 C 21:22:50 Temperature Measurement, Probe Number = 3, T = 20.029000 C 21:22:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:22:51 Integrated Voltage Measurement... 21:23:10 Voltage Offset Correction: v_off_ini = 0.000000549 V, v_off_fin = 0.000005637 V 21:23:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437922 Vs 21:23:10 Integrated Voltage Measurement... 21:23:30 Voltage Offset Correction: v_off_ini = 0.000005163 V, v_off_fin = -0.000001713 V 21:23:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319466 Vs 21:23:33 Temperature Measurement, Probe Number = 0, T = 20.278000 C 21:23:33 Temperature Measurement, Probe Number = 1, T = 20.086000 C 21:23:34 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:23:34 Temperature Measurement, Probe Number = 3, T = 20.031000 C 21:23:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:23:35 Integrated Voltage Measurement... 21:23:54 Voltage Offset Correction: v_off_ini = 0.000001385 V, v_off_fin = 0.000005511 V 21:23:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432737 Vs 21:23:54 Integrated Voltage Measurement... 21:24:14 Voltage Offset Correction: v_off_ini = 0.000004859 V, v_off_fin = -0.000003177 V 21:24:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175332870 Vs 21:24:16 Temperature Measurement, Probe Number = 0, T = 20.283000 C 21:24:17 Temperature Measurement, Probe Number = 1, T = 20.085000 C 21:24:18 Temperature Measurement, Probe Number = 2, T = 20.056000 C 21:24:18 Temperature Measurement, Probe Number = 3, T = 20.027000 C 21:24:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.09 P2 = Bottom 3, Value = 20.06 P3 = Top 1, Value = 20.03 21:24:19 Integrated Voltage Measurement... 21:24:38 Voltage Offset Correction: v_off_ini = 0.000000267 V, v_off_fin = 0.000005503 V 21:24:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435588 Vs 21:24:38 Integrated Voltage Measurement... 21:24:57 Voltage Offset Correction: v_off_ini = 0.000004782 V, v_off_fin = -0.000003370 V 21:24:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175328931 Vs 21:25:00 Temperature Measurement, Probe Number = 0, T = 20.305000 C 21:25:01 Temperature Measurement, Probe Number = 1, T = 20.082000 C 21:25:01 Temperature Measurement, Probe Number = 2, T = 20.055000 C 21:25:02 Temperature Measurement, Probe Number = 3, T = 20.027000 C 21:25:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:25:02 Integrated Voltage Measurement... 21:25:21 Voltage Offset Correction: v_off_ini = 0.000000942 V, v_off_fin = 0.000005894 V 21:25:21 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175439705 Vs 21:25:21 Integrated Voltage Measurement... 21:25:40 Voltage Offset Correction: v_off_ini = 0.000005261 V, v_off_fin = -0.000002597 V 21:25:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175323704 Vs 21:55:43 Temperature Measurement, Probe Number = 0, T = 20.214000 C 21:55:44 Temperature Measurement, Probe Number = 1, T = 20.078000 C 21:55:44 Temperature Measurement, Probe Number = 2, T = 20.048000 C 21:55:45 Temperature Measurement, Probe Number = 3, T = 20.024000 C 21:55:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:55:45 Integrated Voltage Measurement... 21:56:05 Voltage Offset Correction: v_off_ini = 0.000002615 V, v_off_fin = 0.000005752 V 21:56:05 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175533965 Vs 21:56:05 Integrated Voltage Measurement... 21:56:24 Voltage Offset Correction: v_off_ini = 0.000004859 V, v_off_fin = -0.000003137 V 21:56:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322728 Vs 21:56:27 Temperature Measurement, Probe Number = 0, T = 20.244000 C 21:56:27 Temperature Measurement, Probe Number = 1, T = 20.082000 C 21:56:28 Temperature Measurement, Probe Number = 2, T = 20.052000 C 21:56:29 Temperature Measurement, Probe Number = 3, T = 20.029000 C 21:56:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:56:29 Integrated Voltage Measurement... 21:56:48 Voltage Offset Correction: v_off_ini = 0.000000914 V, v_off_fin = 0.000005661 V 21:56:48 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175435885 Vs 21:56:48 Integrated Voltage Measurement... 21:57:07 Voltage Offset Correction: v_off_ini = 0.000004749 V, v_off_fin = -0.000003238 V 21:57:07 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175322390 Vs 21:57:10 Temperature Measurement, Probe Number = 0, T = 20.244000 C 21:57:11 Temperature Measurement, Probe Number = 1, T = 20.078000 C 21:57:11 Temperature Measurement, Probe Number = 2, T = 20.052000 C 21:57:12 Temperature Measurement, Probe Number = 3, T = 20.025000 C 21:57:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 21:57:12 Integrated Voltage Measurement... 21:57:31 Voltage Offset Correction: v_off_ini = 0.000000562 V, v_off_fin = 0.000005192 V 21:57:31 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175439535 Vs 21:57:32 Integrated Voltage Measurement... 21:57:51 Voltage Offset Correction: v_off_ini = 0.000004784 V, v_off_fin = -0.000002522 V 21:57:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322607 Vs 21:57:54 Temperature Measurement, Probe Number = 0, T = 20.219000 C 21:57:54 Temperature Measurement, Probe Number = 1, T = 20.075000 C 21:57:55 Temperature Measurement, Probe Number = 2, T = 20.052000 C 21:57:55 Temperature Measurement, Probe Number = 3, T = 20.026000 C 21:57:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:57:56 Integrated Voltage Measurement... 21:58:15 Voltage Offset Correction: v_off_ini = 0.000001103 V, v_off_fin = 0.000005878 V 21:58:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443504 Vs 21:58:15 Integrated Voltage Measurement... 21:58:35 Voltage Offset Correction: v_off_ini = 0.000005053 V, v_off_fin = -0.000002725 V 21:58:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326426 Vs 21:58:38 Temperature Measurement, Probe Number = 0, T = 20.191000 C 21:58:38 Temperature Measurement, Probe Number = 1, T = 20.077000 C 21:58:39 Temperature Measurement, Probe Number = 2, T = 20.052000 C 21:58:40 Temperature Measurement, Probe Number = 3, T = 20.027000 C 21:58:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:58:40 Integrated Voltage Measurement... 21:58:59 Voltage Offset Correction: v_off_ini = 0.000000730 V, v_off_fin = 0.000005911 V 21:58:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440337 Vs 21:58:59 Integrated Voltage Measurement... 21:59:18 Voltage Offset Correction: v_off_ini = 0.000004829 V, v_off_fin = -0.000002860 V 21:59:18 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175321169 Vs 21:59:21 Temperature Measurement, Probe Number = 0, T = 20.218000 C 21:59:22 Temperature Measurement, Probe Number = 1, T = 20.078000 C 21:59:22 Temperature Measurement, Probe Number = 2, T = 20.047000 C 21:59:23 Temperature Measurement, Probe Number = 3, T = 20.027000 C 21:59:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 21:59:23 Integrated Voltage Measurement... 21:59:42 Voltage Offset Correction: v_off_ini = 0.000000847 V, v_off_fin = 0.000005301 V 21:59:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439685 Vs 21:59:43 Integrated Voltage Measurement... 22:00:02 Voltage Offset Correction: v_off_ini = 0.000004676 V, v_off_fin = -0.000003192 V 22:00:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175331337 Vs 22:00:05 Temperature Measurement, Probe Number = 0, T = 20.241000 C 22:00:05 Temperature Measurement, Probe Number = 1, T = 20.078000 C 22:00:06 Temperature Measurement, Probe Number = 2, T = 20.049000 C 22:00:06 Temperature Measurement, Probe Number = 3, T = 20.028000 C 22:00:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.03 22:00:07 Integrated Voltage Measurement... 22:00:26 Voltage Offset Correction: v_off_ini = 0.000001287 V, v_off_fin = 0.000005220 V 22:00:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434754 Vs 22:00:26 Integrated Voltage Measurement... 22:00:45 Voltage Offset Correction: v_off_ini = 0.000005025 V, v_off_fin = -0.000002729 V 22:00:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323608 Vs 22:00:48 Temperature Measurement, Probe Number = 0, T = 20.238000 C 22:00:49 Temperature Measurement, Probe Number = 1, T = 20.078000 C 22:00:49 Temperature Measurement, Probe Number = 2, T = 20.053000 C 22:00:50 Temperature Measurement, Probe Number = 3, T = 20.025000 C 22:00:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 22:00:50 Integrated Voltage Measurement... 22:01:09 Voltage Offset Correction: v_off_ini = 0.000001015 V, v_off_fin = 0.000005385 V 22:01:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434682 Vs 22:01:10 Integrated Voltage Measurement... 22:01:29 Voltage Offset Correction: v_off_ini = 0.000005092 V, v_off_fin = -0.000002790 V 22:01:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175336859 Vs 22:01:32 Temperature Measurement, Probe Number = 0, T = 20.229000 C 22:01:33 Temperature Measurement, Probe Number = 1, T = 20.079000 C 22:01:33 Temperature Measurement, Probe Number = 2, T = 20.053000 C 22:01:34 Temperature Measurement, Probe Number = 3, T = 20.022000 C 22:01:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 22:01:34 Integrated Voltage Measurement... 22:01:53 Voltage Offset Correction: v_off_ini = 0.000000041 V, v_off_fin = 0.000005101 V 22:01:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435017 Vs 22:01:54 Integrated Voltage Measurement... 22:02:13 Voltage Offset Correction: v_off_ini = 0.000004219 V, v_off_fin = -0.000003114 V 22:02:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175338734 Vs 22:02:16 Temperature Measurement, Probe Number = 0, T = 20.198000 C 22:02:17 Temperature Measurement, Probe Number = 1, T = 20.077000 C 22:02:17 Temperature Measurement, Probe Number = 2, T = 20.051000 C 22:02:18 Temperature Measurement, Probe Number = 3, T = 20.025000 C 22:02:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.08 P2 = Bottom 3, Value = 20.05 P3 = Top 1, Value = 20.02 22:02:18 Integrated Voltage Measurement... 22:02:37 Voltage Offset Correction: v_off_ini = 0.000000526 V, v_off_fin = 0.000005207 V 22:02:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437416 Vs 22:02:38 Integrated Voltage Measurement... 22:02:57 Voltage Offset Correction: v_off_ini = 0.000004415 V, v_off_fin = -0.000003280 V 22:02:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175326038 Vs 22:33:00 Temperature Measurement, Probe Number = 0, T = 20.151000 C 22:33:00 Temperature Measurement, Probe Number = 1, T = 20.065000 C 22:33:01 Temperature Measurement, Probe Number = 2, T = 20.032000 C 22:33:01 Temperature Measurement, Probe Number = 3, T = 20.015000 C 22:33:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.02 22:33:02 Integrated Voltage Measurement... 22:33:21 Voltage Offset Correction: v_off_ini = 0.000003645 V, v_off_fin = 0.000005965 V 22:33:21 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175536387 Vs 22:33:21 Integrated Voltage Measurement... 22:33:40 Voltage Offset Correction: v_off_ini = 0.000005137 V, v_off_fin = -0.000002946 V 22:33:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175325505 Vs 22:33:43 Temperature Measurement, Probe Number = 0, T = 20.157000 C 22:33:44 Temperature Measurement, Probe Number = 1, T = 20.066000 C 22:33:44 Temperature Measurement, Probe Number = 2, T = 20.034000 C 22:33:45 Temperature Measurement, Probe Number = 3, T = 20.017000 C 22:33:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.02 22:33:45 Integrated Voltage Measurement... 22:34:05 Voltage Offset Correction: v_off_ini = 0.000000236 V, v_off_fin = 0.000005186 V 22:34:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435552 Vs 22:34:05 Integrated Voltage Measurement... 22:34:24 Voltage Offset Correction: v_off_ini = 0.000003802 V, v_off_fin = -0.000003691 V 22:34:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175333666 Vs 22:34:27 Temperature Measurement, Probe Number = 0, T = 20.173000 C 22:34:28 Temperature Measurement, Probe Number = 1, T = 20.070000 C 22:34:28 Temperature Measurement, Probe Number = 2, T = 20.040000 C 22:34:29 Temperature Measurement, Probe Number = 3, T = 20.017000 C 22:34:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:34:29 Integrated Voltage Measurement... 22:34:48 Voltage Offset Correction: v_off_ini = -0.000000226 V, v_off_fin = 0.000005710 V 22:34:49 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175442084 Vs 22:34:49 Integrated Voltage Measurement... 22:35:08 Voltage Offset Correction: v_off_ini = 0.000005005 V, v_off_fin = -0.000003179 V 22:35:08 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175334674 Vs 22:35:11 Temperature Measurement, Probe Number = 0, T = 20.177000 C 22:35:12 Temperature Measurement, Probe Number = 1, T = 20.071000 C 22:35:12 Temperature Measurement, Probe Number = 2, T = 20.042000 C 22:35:13 Temperature Measurement, Probe Number = 3, T = 20.020000 C 22:35:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:35:13 Integrated Voltage Measurement... 22:35:32 Voltage Offset Correction: v_off_ini = 0.000001133 V, v_off_fin = 0.000005324 V 22:35:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441509 Vs 22:35:33 Integrated Voltage Measurement... 22:35:52 Voltage Offset Correction: v_off_ini = 0.000004366 V, v_off_fin = -0.000003509 V 22:35:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175336401 Vs 22:35:55 Temperature Measurement, Probe Number = 0, T = 20.243000 C 22:35:56 Temperature Measurement, Probe Number = 1, T = 20.072000 C 22:35:56 Temperature Measurement, Probe Number = 2, T = 20.042000 C 22:35:57 Temperature Measurement, Probe Number = 3, T = 20.022000 C 22:35:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:35:57 Integrated Voltage Measurement... 22:36:17 Voltage Offset Correction: v_off_ini = 0.000000176 V, v_off_fin = 0.000005486 V 22:36:17 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435544 Vs 22:36:17 Integrated Voltage Measurement... 22:36:36 Voltage Offset Correction: v_off_ini = 0.000004497 V, v_off_fin = -0.000003349 V 22:36:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175339500 Vs 22:36:39 Temperature Measurement, Probe Number = 0, T = 20.254000 C 22:36:40 Temperature Measurement, Probe Number = 1, T = 20.067000 C 22:36:40 Temperature Measurement, Probe Number = 2, T = 20.039000 C 22:36:41 Temperature Measurement, Probe Number = 3, T = 20.020000 C 22:36:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:36:41 Integrated Voltage Measurement... 22:37:01 Voltage Offset Correction: v_off_ini = 0.000000331 V, v_off_fin = 0.000005185 V 22:37:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175444279 Vs 22:37:01 Integrated Voltage Measurement... 22:37:21 Voltage Offset Correction: v_off_ini = 0.000004301 V, v_off_fin = -0.000003096 V 22:37:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175329730 Vs 22:37:23 Temperature Measurement, Probe Number = 0, T = 20.225000 C 22:37:24 Temperature Measurement, Probe Number = 1, T = 20.069000 C 22:37:25 Temperature Measurement, Probe Number = 2, T = 20.038000 C 22:37:25 Temperature Measurement, Probe Number = 3, T = 20.016000 C 22:37:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:37:26 Integrated Voltage Measurement... 22:37:45 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = 0.000005230 V 22:37:45 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437780 Vs 22:37:45 Integrated Voltage Measurement... 22:38:04 Voltage Offset Correction: v_off_ini = 0.000004911 V, v_off_fin = -0.000002482 V 22:38:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175330962 Vs 22:38:07 Temperature Measurement, Probe Number = 0, T = 20.204000 C 22:38:08 Temperature Measurement, Probe Number = 1, T = 20.067000 C 22:38:08 Temperature Measurement, Probe Number = 2, T = 20.038000 C 22:38:09 Temperature Measurement, Probe Number = 3, T = 20.013000 C 22:38:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 22:38:09 Integrated Voltage Measurement... 22:38:29 Voltage Offset Correction: v_off_ini = 0.000000727 V, v_off_fin = 0.000005274 V 22:38:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441804 Vs 22:38:29 Integrated Voltage Measurement... 22:38:48 Voltage Offset Correction: v_off_ini = 0.000004555 V, v_off_fin = -0.000003145 V 22:38:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175332708 Vs 22:38:51 Temperature Measurement, Probe Number = 0, T = 20.210000 C 22:38:52 Temperature Measurement, Probe Number = 1, T = 20.069000 C 22:38:53 Temperature Measurement, Probe Number = 2, T = 20.035000 C 22:38:53 Temperature Measurement, Probe Number = 3, T = 20.017000 C 22:38:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:38:53 Integrated Voltage Measurement... 22:39:13 Voltage Offset Correction: v_off_ini = 0.000000975 V, v_off_fin = 0.000006018 V 22:39:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450073 Vs 22:39:13 Integrated Voltage Measurement... 22:39:33 Voltage Offset Correction: v_off_ini = 0.000005116 V, v_off_fin = -0.000001917 V 22:39:33 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175331955 Vs 22:39:36 Temperature Measurement, Probe Number = 0, T = 20.228000 C 22:39:36 Temperature Measurement, Probe Number = 1, T = 20.067000 C 22:39:37 Temperature Measurement, Probe Number = 2, T = 20.037000 C 22:39:38 Temperature Measurement, Probe Number = 3, T = 20.019000 C 22:39:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 22:39:38 Integrated Voltage Measurement... 22:39:57 Voltage Offset Correction: v_off_ini = 0.000001815 V, v_off_fin = 0.000006000 V 22:39:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445050 Vs 22:39:57 Integrated Voltage Measurement... 22:40:16 Voltage Offset Correction: v_off_ini = 0.000005320 V, v_off_fin = -0.000002053 V 22:40:17 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175327362 Vs 23:10:19 Temperature Measurement, Probe Number = 0, T = 20.135000 C 23:10:20 Temperature Measurement, Probe Number = 1, T = 20.060000 C 23:10:21 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:10:21 Temperature Measurement, Probe Number = 3, T = 20.012000 C 23:10:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:10:21 Integrated Voltage Measurement... 23:10:41 Voltage Offset Correction: v_off_ini = 0.000003529 V, v_off_fin = 0.000005661 V 23:10:41 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175531985 Vs 23:10:41 Integrated Voltage Measurement... 23:11:00 Voltage Offset Correction: v_off_ini = 0.000004958 V, v_off_fin = -0.000002890 V 23:11:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175328670 Vs 23:11:03 Temperature Measurement, Probe Number = 0, T = 20.074000 C 23:11:04 Temperature Measurement, Probe Number = 1, T = 20.060000 C 23:11:04 Temperature Measurement, Probe Number = 2, T = 20.025000 C 23:11:05 Temperature Measurement, Probe Number = 3, T = 20.010000 C 23:11:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 23:11:05 Integrated Voltage Measurement... 23:11:24 Voltage Offset Correction: v_off_ini = 0.000000752 V, v_off_fin = 0.000005638 V 23:11:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439521 Vs 23:11:25 Integrated Voltage Measurement... 23:11:44 Voltage Offset Correction: v_off_ini = 0.000004993 V, v_off_fin = -0.000002943 V 23:11:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175327349 Vs 23:11:47 Temperature Measurement, Probe Number = 0, T = 20.120000 C 23:11:47 Temperature Measurement, Probe Number = 1, T = 20.059000 C 23:11:48 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:11:49 Temperature Measurement, Probe Number = 3, T = 20.009000 C 23:11:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:11:49 Integrated Voltage Measurement... 23:12:08 Voltage Offset Correction: v_off_ini = 0.000000169 V, v_off_fin = 0.000005825 V 23:12:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434896 Vs 23:12:08 Integrated Voltage Measurement... 23:12:27 Voltage Offset Correction: v_off_ini = 0.000004930 V, v_off_fin = -0.000003188 V 23:12:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325372 Vs 23:12:30 Temperature Measurement, Probe Number = 0, T = 20.131000 C 23:12:30 Temperature Measurement, Probe Number = 1, T = 20.058000 C 23:12:31 Temperature Measurement, Probe Number = 2, T = 20.030000 C 23:12:32 Temperature Measurement, Probe Number = 3, T = 20.011000 C 23:12:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:12:32 Integrated Voltage Measurement... 23:12:51 Voltage Offset Correction: v_off_ini = 0.000000107 V, v_off_fin = 0.000005614 V 23:12:51 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442672 Vs 23:12:51 Integrated Voltage Measurement... 23:13:11 Voltage Offset Correction: v_off_ini = 0.000004869 V, v_off_fin = -0.000003022 V 23:13:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175332708 Vs 23:13:13 Temperature Measurement, Probe Number = 0, T = 20.076000 C 23:13:14 Temperature Measurement, Probe Number = 1, T = 20.059000 C 23:13:15 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:13:15 Temperature Measurement, Probe Number = 3, T = 20.011000 C 23:13:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:13:15 Integrated Voltage Measurement... 23:13:35 Voltage Offset Correction: v_off_ini = 0.000001493 V, v_off_fin = 0.000005611 V 23:13:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439885 Vs 23:13:36 Integrated Voltage Measurement... 23:13:55 Voltage Offset Correction: v_off_ini = 0.000004944 V, v_off_fin = -0.000003000 V 23:13:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325496 Vs 23:13:58 Temperature Measurement, Probe Number = 0, T = 20.090000 C 23:13:58 Temperature Measurement, Probe Number = 1, T = 20.062000 C 23:13:59 Temperature Measurement, Probe Number = 2, T = 20.031000 C 23:14:00 Temperature Measurement, Probe Number = 3, T = 20.012000 C 23:14:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:14:00 Integrated Voltage Measurement... 23:14:19 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000005901 V 23:14:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175447796 Vs 23:14:19 Integrated Voltage Measurement... 23:14:39 Voltage Offset Correction: v_off_ini = 0.000004657 V, v_off_fin = -0.000002809 V 23:14:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175334347 Vs 23:14:42 Temperature Measurement, Probe Number = 0, T = 20.148000 C 23:14:43 Temperature Measurement, Probe Number = 1, T = 20.059000 C 23:14:43 Temperature Measurement, Probe Number = 2, T = 20.026000 C 23:14:44 Temperature Measurement, Probe Number = 3, T = 20.011000 C 23:14:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:14:44 Integrated Voltage Measurement... 23:15:03 Voltage Offset Correction: v_off_ini = 0.000001360 V, v_off_fin = 0.000005876 V 23:15:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439437 Vs 23:15:04 Integrated Voltage Measurement... 23:15:23 Voltage Offset Correction: v_off_ini = 0.000004843 V, v_off_fin = -0.000002338 V 23:15:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325227 Vs 23:15:26 Temperature Measurement, Probe Number = 0, T = 20.151000 C 23:15:26 Temperature Measurement, Probe Number = 1, T = 20.056000 C 23:15:27 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:15:28 Temperature Measurement, Probe Number = 3, T = 20.009000 C 23:15:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:15:28 Integrated Voltage Measurement... 23:15:47 Voltage Offset Correction: v_off_ini = 0.000000514 V, v_off_fin = 0.000005301 V 23:15:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439298 Vs 23:15:47 Integrated Voltage Measurement... 23:16:06 Voltage Offset Correction: v_off_ini = 0.000005318 V, v_off_fin = -0.000003079 V 23:16:07 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175329268 Vs 23:16:09 Temperature Measurement, Probe Number = 0, T = 20.170000 C 23:16:10 Temperature Measurement, Probe Number = 1, T = 20.058000 C 23:16:11 Temperature Measurement, Probe Number = 2, T = 20.027000 C 23:16:11 Temperature Measurement, Probe Number = 3, T = 20.012000 C 23:16:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 23:16:12 Integrated Voltage Measurement... 23:16:31 Voltage Offset Correction: v_off_ini = 0.000000569 V, v_off_fin = 0.000005565 V 23:16:31 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175443745 Vs 23:16:31 Integrated Voltage Measurement... 23:16:50 Voltage Offset Correction: v_off_ini = 0.000004500 V, v_off_fin = -0.000002584 V 23:16:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175332899 Vs 23:16:53 Temperature Measurement, Probe Number = 0, T = 20.131000 C 23:16:54 Temperature Measurement, Probe Number = 1, T = 20.056000 C 23:16:54 Temperature Measurement, Probe Number = 2, T = 20.024000 C 23:16:55 Temperature Measurement, Probe Number = 3, T = 20.010000 C 23:16:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 23:16:55 Integrated Voltage Measurement... 23:17:14 Voltage Offset Correction: v_off_ini = 0.000001070 V, v_off_fin = 0.000004936 V 23:17:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437288 Vs 23:17:15 Integrated Voltage Measurement... 23:17:34 Voltage Offset Correction: v_off_ini = 0.000004531 V, v_off_fin = -0.000002605 V 23:17:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175331474 Vs 23:47:37 Temperature Measurement, Probe Number = 0, T = 20.001000 C 23:47:38 Temperature Measurement, Probe Number = 1, T = 20.050000 C 23:47:39 Temperature Measurement, Probe Number = 2, T = 20.015000 C 23:47:39 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:47:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.00 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:47:39 Integrated Voltage Measurement... 23:47:59 Voltage Offset Correction: v_off_ini = 0.000004106 V, v_off_fin = 0.000006207 V 23:47:59 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175535469 Vs 23:47:59 Integrated Voltage Measurement... 23:48:18 Voltage Offset Correction: v_off_ini = 0.000005473 V, v_off_fin = -0.000002093 V 23:48:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313359 Vs 23:48:21 Temperature Measurement, Probe Number = 0, T = 19.944000 C 23:48:22 Temperature Measurement, Probe Number = 1, T = 20.048000 C 23:48:22 Temperature Measurement, Probe Number = 2, T = 20.015000 C 23:48:23 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:48:23 Magnet Test Parameter Measurements P0 = Room, Value = 19.94 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:48:23 Integrated Voltage Measurement... 23:48:42 Voltage Offset Correction: v_off_ini = 0.000001289 V, v_off_fin = 0.000006355 V 23:48:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175444876 Vs 23:48:43 Integrated Voltage Measurement... 23:49:02 Voltage Offset Correction: v_off_ini = 0.000005519 V, v_off_fin = -0.000001880 V 23:49:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321021 Vs 23:49:05 Temperature Measurement, Probe Number = 0, T = 20.023000 C 23:49:06 Temperature Measurement, Probe Number = 1, T = 20.051000 C 23:49:06 Temperature Measurement, Probe Number = 2, T = 20.020000 C 23:49:07 Temperature Measurement, Probe Number = 3, T = 20.006000 C 23:49:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.02 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 23:49:07 Integrated Voltage Measurement... 23:49:26 Voltage Offset Correction: v_off_ini = 0.000001589 V, v_off_fin = 0.000006136 V 23:49:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445312 Vs 23:49:27 Integrated Voltage Measurement... 23:49:46 Voltage Offset Correction: v_off_ini = 0.000004876 V, v_off_fin = -0.000001742 V 23:49:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175330292 Vs 23:49:49 Temperature Measurement, Probe Number = 0, T = 20.048000 C 23:49:49 Temperature Measurement, Probe Number = 1, T = 20.049000 C 23:49:50 Temperature Measurement, Probe Number = 2, T = 20.019000 C 23:49:51 Temperature Measurement, Probe Number = 3, T = 20.007000 C 23:49:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 23:49:51 Integrated Voltage Measurement... 23:50:10 Voltage Offset Correction: v_off_ini = 0.000001562 V, v_off_fin = 0.000006212 V 23:50:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443538 Vs 23:50:10 Integrated Voltage Measurement... 23:50:30 Voltage Offset Correction: v_off_ini = 0.000005809 V, v_off_fin = -0.000001095 V 23:50:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317884 Vs 23:50:32 Temperature Measurement, Probe Number = 0, T = 20.091000 C 23:50:33 Temperature Measurement, Probe Number = 1, T = 20.051000 C 23:50:34 Temperature Measurement, Probe Number = 2, T = 20.022000 C 23:50:34 Temperature Measurement, Probe Number = 3, T = 20.005000 C 23:50:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:50:34 Integrated Voltage Measurement... 23:50:54 Voltage Offset Correction: v_off_ini = 0.000002331 V, v_off_fin = 0.000007141 V 23:50:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175453544 Vs 23:50:54 Integrated Voltage Measurement... 23:51:13 Voltage Offset Correction: v_off_ini = 0.000005985 V, v_off_fin = -0.000001636 V 23:51:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308841 Vs 23:51:16 Temperature Measurement, Probe Number = 0, T = 20.053000 C 23:51:17 Temperature Measurement, Probe Number = 1, T = 20.053000 C 23:51:17 Temperature Measurement, Probe Number = 2, T = 20.021000 C 23:51:18 Temperature Measurement, Probe Number = 3, T = 20.004000 C 23:51:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:51:18 Integrated Voltage Measurement... 23:51:38 Voltage Offset Correction: v_off_ini = 0.000002294 V, v_off_fin = 0.000006319 V 23:51:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448598 Vs 23:51:38 Integrated Voltage Measurement... 23:51:57 Voltage Offset Correction: v_off_ini = 0.000005805 V, v_off_fin = -0.000001523 V 23:51:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317876 Vs 23:52:00 Temperature Measurement, Probe Number = 0, T = 20.075000 C 23:52:01 Temperature Measurement, Probe Number = 1, T = 20.050000 C 23:52:01 Temperature Measurement, Probe Number = 2, T = 20.017000 C 23:52:02 Temperature Measurement, Probe Number = 3, T = 20.001000 C 23:52:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:52:02 Integrated Voltage Measurement... 23:52:21 Voltage Offset Correction: v_off_ini = 0.000001477 V, v_off_fin = 0.000006095 V 23:52:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443986 Vs 23:52:22 Integrated Voltage Measurement... 23:52:41 Voltage Offset Correction: v_off_ini = 0.000005138 V, v_off_fin = -0.000002166 V 23:52:41 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175315697 Vs 23:52:43 Temperature Measurement, Probe Number = 0, T = 20.067000 C 23:52:44 Temperature Measurement, Probe Number = 1, T = 20.047000 C 23:52:45 Temperature Measurement, Probe Number = 2, T = 20.016000 C 23:52:45 Temperature Measurement, Probe Number = 3, T = 20.002000 C 23:52:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:52:46 Integrated Voltage Measurement... 23:53:05 Voltage Offset Correction: v_off_ini = 0.000001610 V, v_off_fin = 0.000006434 V 23:53:05 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175448537 Vs 23:53:05 Integrated Voltage Measurement... 23:53:24 Voltage Offset Correction: v_off_ini = 0.000006181 V, v_off_fin = -0.000001546 V 23:53:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322094 Vs 23:53:27 Temperature Measurement, Probe Number = 0, T = 20.077000 C 23:53:28 Temperature Measurement, Probe Number = 1, T = 20.048000 C 23:53:28 Temperature Measurement, Probe Number = 2, T = 20.017000 C 23:53:29 Temperature Measurement, Probe Number = 3, T = 20.004000 C 23:53:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:53:29 Integrated Voltage Measurement... 23:53:48 Voltage Offset Correction: v_off_ini = 0.000001489 V, v_off_fin = 0.000006367 V 23:53:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443101 Vs 23:53:49 Integrated Voltage Measurement... 23:54:08 Voltage Offset Correction: v_off_ini = 0.000005638 V, v_off_fin = -0.000001988 V 23:54:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315153 Vs 23:54:10 Temperature Measurement, Probe Number = 0, T = 20.111000 C 23:54:11 Temperature Measurement, Probe Number = 1, T = 20.047000 C 23:54:12 Temperature Measurement, Probe Number = 2, T = 20.018000 C 23:54:12 Temperature Measurement, Probe Number = 3, T = 20.003000 C 23:54:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 23:54:13 Integrated Voltage Measurement... 23:54:32 Voltage Offset Correction: v_off_ini = 0.000001710 V, v_off_fin = 0.000006255 V 23:54:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175450786 Vs 23:54:32 Integrated Voltage Measurement... 23:54:51 Voltage Offset Correction: v_off_ini = 0.000005513 V, v_off_fin = -0.000002344 V 23:54:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325060 Vs 00:24:54 Temperature Measurement, Probe Number = 0, T = 20.092000 C 00:24:55 Temperature Measurement, Probe Number = 1, T = 20.040000 C 00:24:56 Temperature Measurement, Probe Number = 2, T = 20.007000 C 00:24:56 Temperature Measurement, Probe Number = 3, T = 19.996000 C 00:24:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:24:56 Integrated Voltage Measurement... 00:25:16 Voltage Offset Correction: v_off_ini = 0.000004569 V, v_off_fin = 0.000006451 V 00:25:16 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175533556 Vs 00:25:16 Integrated Voltage Measurement... 00:25:35 Voltage Offset Correction: v_off_ini = 0.000005872 V, v_off_fin = -0.000001323 V 00:25:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314732 Vs 00:25:38 Temperature Measurement, Probe Number = 0, T = 20.151000 C 00:25:39 Temperature Measurement, Probe Number = 1, T = 20.042000 C 00:25:40 Temperature Measurement, Probe Number = 2, T = 20.006000 C 00:25:40 Temperature Measurement, Probe Number = 3, T = 19.999000 C 00:25:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:25:40 Integrated Voltage Measurement... 00:25:59 Voltage Offset Correction: v_off_ini = 0.000001919 V, v_off_fin = 0.000006593 V 00:26:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444136 Vs 00:26:00 Integrated Voltage Measurement... 00:26:19 Voltage Offset Correction: v_off_ini = 0.000005637 V, v_off_fin = -0.000002218 V 00:26:19 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175312410 Vs 00:26:21 Temperature Measurement, Probe Number = 0, T = 20.163000 C 00:26:22 Temperature Measurement, Probe Number = 1, T = 20.042000 C 00:26:23 Temperature Measurement, Probe Number = 2, T = 20.009000 C 00:26:23 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:26:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:26:24 Integrated Voltage Measurement... 00:26:43 Voltage Offset Correction: v_off_ini = 0.000001051 V, v_off_fin = 0.000005675 V 00:26:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441770 Vs 00:26:43 Integrated Voltage Measurement... 00:27:02 Voltage Offset Correction: v_off_ini = 0.000004911 V, v_off_fin = -0.000002399 V 00:27:02 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175315233 Vs 00:27:05 Temperature Measurement, Probe Number = 0, T = 20.156000 C 00:27:05 Temperature Measurement, Probe Number = 1, T = 20.041000 C 00:27:06 Temperature Measurement, Probe Number = 2, T = 20.011000 C 00:27:07 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:27:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:27:07 Integrated Voltage Measurement... 00:27:26 Voltage Offset Correction: v_off_ini = 0.000001910 V, v_off_fin = 0.000006526 V 00:27:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175450292 Vs 00:27:26 Integrated Voltage Measurement... 00:27:45 Voltage Offset Correction: v_off_ini = 0.000005412 V, v_off_fin = -0.000001980 V 00:27:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321889 Vs 00:27:48 Temperature Measurement, Probe Number = 0, T = 20.156000 C 00:27:49 Temperature Measurement, Probe Number = 1, T = 20.044000 C 00:27:50 Temperature Measurement, Probe Number = 2, T = 20.010000 C 00:27:50 Temperature Measurement, Probe Number = 3, T = 19.999000 C 00:27:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:27:51 Integrated Voltage Measurement... 00:28:10 Voltage Offset Correction: v_off_ini = 0.000001230 V, v_off_fin = 0.000005511 V 00:28:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441598 Vs 00:28:10 Integrated Voltage Measurement... 00:28:29 Voltage Offset Correction: v_off_ini = 0.000005157 V, v_off_fin = -0.000002413 V 00:28:29 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175316802 Vs 00:28:32 Temperature Measurement, Probe Number = 0, T = 20.138000 C 00:28:33 Temperature Measurement, Probe Number = 1, T = 20.045000 C 00:28:33 Temperature Measurement, Probe Number = 2, T = 20.010000 C 00:28:34 Temperature Measurement, Probe Number = 3, T = 20.000000 C 00:28:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:28:34 Integrated Voltage Measurement... 00:28:54 Voltage Offset Correction: v_off_ini = 0.000001412 V, v_off_fin = 0.000005883 V 00:28:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441460 Vs 00:28:54 Integrated Voltage Measurement... 00:29:14 Voltage Offset Correction: v_off_ini = 0.000004954 V, v_off_fin = -0.000002451 V 00:29:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175326796 Vs 00:29:16 Temperature Measurement, Probe Number = 0, T = 20.167000 C 00:29:17 Temperature Measurement, Probe Number = 1, T = 20.044000 C 00:29:18 Temperature Measurement, Probe Number = 2, T = 20.008000 C 00:29:18 Temperature Measurement, Probe Number = 3, T = 19.998000 C 00:29:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:29:19 Integrated Voltage Measurement... 00:29:38 Voltage Offset Correction: v_off_ini = 0.000001075 V, v_off_fin = 0.000005755 V 00:29:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437269 Vs 00:29:38 Integrated Voltage Measurement... 00:29:58 Voltage Offset Correction: v_off_ini = 0.000005291 V, v_off_fin = -0.000002956 V 00:29:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325977 Vs 00:30:01 Temperature Measurement, Probe Number = 0, T = 20.125000 C 00:30:01 Temperature Measurement, Probe Number = 1, T = 20.043000 C 00:30:02 Temperature Measurement, Probe Number = 2, T = 20.006000 C 00:30:02 Temperature Measurement, Probe Number = 3, T = 19.997000 C 00:30:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:30:03 Integrated Voltage Measurement... 00:30:22 Voltage Offset Correction: v_off_ini = 0.000000949 V, v_off_fin = 0.000006609 V 00:30:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445625 Vs 00:30:22 Integrated Voltage Measurement... 00:30:42 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000000735 V 00:30:42 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311267 Vs 00:30:45 Temperature Measurement, Probe Number = 0, T = 20.128000 C 00:30:46 Temperature Measurement, Probe Number = 1, T = 20.043000 C 00:30:46 Temperature Measurement, Probe Number = 2, T = 20.006000 C 00:30:47 Temperature Measurement, Probe Number = 3, T = 19.996000 C 00:30:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:30:47 Integrated Voltage Measurement... 00:31:06 Voltage Offset Correction: v_off_ini = 0.000001887 V, v_off_fin = 0.000006190 V 00:31:06 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175435190 Vs 00:31:06 Integrated Voltage Measurement... 00:31:26 Voltage Offset Correction: v_off_ini = 0.000005846 V, v_off_fin = -0.000000729 V 00:31:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316539 Vs 00:31:29 Temperature Measurement, Probe Number = 0, T = 20.144000 C 00:31:29 Temperature Measurement, Probe Number = 1, T = 20.045000 C 00:31:30 Temperature Measurement, Probe Number = 2, T = 20.010000 C 00:31:31 Temperature Measurement, Probe Number = 3, T = 20.000000 C 00:31:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 00:31:31 Integrated Voltage Measurement... 00:31:50 Voltage Offset Correction: v_off_ini = 0.000002176 V, v_off_fin = 0.000006172 V 00:31:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437479 Vs 00:31:50 Integrated Voltage Measurement... 00:32:09 Voltage Offset Correction: v_off_ini = 0.000005643 V, v_off_fin = -0.000001416 V 00:32:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309286 Vs 01:02:12 Temperature Measurement, Probe Number = 0, T = 20.299000 C 01:02:13 Temperature Measurement, Probe Number = 1, T = 20.041000 C 01:02:13 Temperature Measurement, Probe Number = 2, T = 20.013000 C 01:02:14 Temperature Measurement, Probe Number = 3, T = 19.998000 C 01:02:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:02:14 Integrated Voltage Measurement... 01:02:33 Voltage Offset Correction: v_off_ini = 0.000003161 V, v_off_fin = 0.000005433 V 01:02:33 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175527926 Vs 01:02:33 Integrated Voltage Measurement... 01:02:53 Voltage Offset Correction: v_off_ini = 0.000004930 V, v_off_fin = -0.000002496 V 01:02:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316029 Vs 01:02:56 Temperature Measurement, Probe Number = 0, T = 20.248000 C 01:02:56 Temperature Measurement, Probe Number = 1, T = 20.042000 C 01:02:57 Temperature Measurement, Probe Number = 2, T = 20.012000 C 01:02:58 Temperature Measurement, Probe Number = 3, T = 19.999000 C 01:02:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:02:58 Integrated Voltage Measurement... 01:03:17 Voltage Offset Correction: v_off_ini = 0.000000684 V, v_off_fin = 0.000005378 V 01:03:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418869 Vs 01:03:17 Integrated Voltage Measurement... 01:03:36 Voltage Offset Correction: v_off_ini = 0.000004995 V, v_off_fin = -0.000002859 V 01:03:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175311612 Vs 01:03:39 Temperature Measurement, Probe Number = 0, T = 20.226000 C 01:03:40 Temperature Measurement, Probe Number = 1, T = 20.042000 C 01:03:40 Temperature Measurement, Probe Number = 2, T = 20.013000 C 01:03:41 Temperature Measurement, Probe Number = 3, T = 19.999000 C 01:03:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:03:41 Integrated Voltage Measurement... 01:04:01 Voltage Offset Correction: v_off_ini = 0.000000360 V, v_off_fin = 0.000005139 V 01:04:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425129 Vs 01:04:02 Integrated Voltage Measurement... 01:04:21 Voltage Offset Correction: v_off_ini = 0.000004449 V, v_off_fin = -0.000002934 V 01:04:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319903 Vs 01:04:24 Temperature Measurement, Probe Number = 0, T = 20.220000 C 01:04:24 Temperature Measurement, Probe Number = 1, T = 20.044000 C 01:04:25 Temperature Measurement, Probe Number = 2, T = 20.013000 C 01:04:26 Temperature Measurement, Probe Number = 3, T = 20.000000 C 01:04:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:04:26 Integrated Voltage Measurement... 01:04:45 Voltage Offset Correction: v_off_ini = 0.000000729 V, v_off_fin = 0.000005409 V 01:04:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423148 Vs 01:04:46 Integrated Voltage Measurement... 01:05:05 Voltage Offset Correction: v_off_ini = 0.000004458 V, v_off_fin = -0.000003071 V 01:05:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322894 Vs 01:05:08 Temperature Measurement, Probe Number = 0, T = 20.232000 C 01:05:08 Temperature Measurement, Probe Number = 1, T = 20.045000 C 01:05:09 Temperature Measurement, Probe Number = 2, T = 20.014000 C 01:05:10 Temperature Measurement, Probe Number = 3, T = 20.000000 C 01:05:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:05:10 Integrated Voltage Measurement... 01:05:29 Voltage Offset Correction: v_off_ini = 0.000000494 V, v_off_fin = 0.000005268 V 01:05:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418274 Vs 01:05:30 Integrated Voltage Measurement... 01:05:49 Voltage Offset Correction: v_off_ini = 0.000004469 V, v_off_fin = -0.000003016 V 01:05:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175330476 Vs 01:05:52 Temperature Measurement, Probe Number = 0, T = 20.262000 C 01:05:53 Temperature Measurement, Probe Number = 1, T = 20.045000 C 01:05:53 Temperature Measurement, Probe Number = 2, T = 20.016000 C 01:05:54 Temperature Measurement, Probe Number = 3, T = 20.003000 C 01:05:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 01:05:54 Integrated Voltage Measurement... 01:06:13 Voltage Offset Correction: v_off_ini = 0.000000525 V, v_off_fin = 0.000005892 V 01:06:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421559 Vs 01:06:14 Integrated Voltage Measurement... 01:06:33 Voltage Offset Correction: v_off_ini = 0.000004986 V, v_off_fin = -0.000002228 V 01:06:33 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175315369 Vs 01:06:35 Temperature Measurement, Probe Number = 0, T = 20.251000 C 01:06:36 Temperature Measurement, Probe Number = 1, T = 20.047000 C 01:06:37 Temperature Measurement, Probe Number = 2, T = 20.016000 C 01:06:37 Temperature Measurement, Probe Number = 3, T = 20.005000 C 01:06:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 01:06:38 Integrated Voltage Measurement... 01:06:56 Voltage Offset Correction: v_off_ini = 0.000000818 V, v_off_fin = 0.000005902 V 01:06:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431756 Vs 01:06:57 Integrated Voltage Measurement... 01:07:16 Voltage Offset Correction: v_off_ini = 0.000005141 V, v_off_fin = -0.000002363 V 01:07:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317466 Vs 01:07:19 Temperature Measurement, Probe Number = 0, T = 20.277000 C 01:07:20 Temperature Measurement, Probe Number = 1, T = 20.044000 C 01:07:20 Temperature Measurement, Probe Number = 2, T = 20.016000 C 01:07:21 Temperature Measurement, Probe Number = 3, T = 20.003000 C 01:07:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 01:07:21 Integrated Voltage Measurement... 01:07:40 Voltage Offset Correction: v_off_ini = 0.000000736 V, v_off_fin = 0.000005949 V 01:07:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433608 Vs 01:07:41 Integrated Voltage Measurement... 01:08:00 Voltage Offset Correction: v_off_ini = 0.000005065 V, v_off_fin = -0.000002269 V 01:08:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322632 Vs 01:08:03 Temperature Measurement, Probe Number = 0, T = 20.247000 C 01:08:04 Temperature Measurement, Probe Number = 1, T = 20.044000 C 01:08:04 Temperature Measurement, Probe Number = 2, T = 20.013000 C 01:08:05 Temperature Measurement, Probe Number = 3, T = 20.002000 C 01:08:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:08:05 Integrated Voltage Measurement... 01:08:25 Voltage Offset Correction: v_off_ini = 0.000001060 V, v_off_fin = 0.000005639 V 01:08:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426196 Vs 01:08:25 Integrated Voltage Measurement... 01:08:45 Voltage Offset Correction: v_off_ini = 0.000004770 V, v_off_fin = -0.000001749 V 01:08:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315441 Vs 01:08:48 Temperature Measurement, Probe Number = 0, T = 20.299000 C 01:08:48 Temperature Measurement, Probe Number = 1, T = 20.043000 C 01:08:49 Temperature Measurement, Probe Number = 2, T = 20.011000 C 01:08:49 Temperature Measurement, Probe Number = 3, T = 20.004000 C 01:08:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:08:50 Integrated Voltage Measurement... 01:09:09 Voltage Offset Correction: v_off_ini = 0.000001582 V, v_off_fin = 0.000005664 V 01:09:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418894 Vs 01:09:09 Integrated Voltage Measurement... 01:09:28 Voltage Offset Correction: v_off_ini = 0.000005135 V, v_off_fin = -0.000002426 V 01:09:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321003 Vs 01:39:31 Temperature Measurement, Probe Number = 0, T = 20.148000 C 01:39:32 Temperature Measurement, Probe Number = 1, T = 20.034000 C 01:39:33 Temperature Measurement, Probe Number = 2, T = 20.000000 C 01:39:33 Temperature Measurement, Probe Number = 3, T = 19.994000 C 01:39:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:39:33 Integrated Voltage Measurement... 01:39:52 Voltage Offset Correction: v_off_ini = 0.000003329 V, v_off_fin = 0.000005541 V 01:39:53 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175514019 Vs 01:39:53 Integrated Voltage Measurement... 01:40:12 Voltage Offset Correction: v_off_ini = 0.000004406 V, v_off_fin = -0.000002859 V 01:40:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320281 Vs 01:40:15 Temperature Measurement, Probe Number = 0, T = 20.149000 C 01:40:16 Temperature Measurement, Probe Number = 1, T = 20.036000 C 01:40:16 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:40:17 Temperature Measurement, Probe Number = 3, T = 19.994000 C 01:40:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:40:17 Integrated Voltage Measurement... 01:40:36 Voltage Offset Correction: v_off_ini = 0.000000869 V, v_off_fin = 0.000005252 V 01:40:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422826 Vs 01:40:37 Integrated Voltage Measurement... 01:40:56 Voltage Offset Correction: v_off_ini = 0.000004824 V, v_off_fin = -0.000002103 V 01:40:56 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175306985 Vs 01:40:59 Temperature Measurement, Probe Number = 0, T = 20.115000 C 01:40:59 Temperature Measurement, Probe Number = 1, T = 20.037000 C 01:41:00 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:41:01 Temperature Measurement, Probe Number = 3, T = 19.993000 C 01:41:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:41:01 Integrated Voltage Measurement... 01:41:21 Voltage Offset Correction: v_off_ini = 0.000001141 V, v_off_fin = 0.000005289 V 01:41:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433237 Vs 01:41:21 Integrated Voltage Measurement... 01:41:40 Voltage Offset Correction: v_off_ini = 0.000004579 V, v_off_fin = -0.000001785 V 01:41:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311514 Vs 01:41:43 Temperature Measurement, Probe Number = 0, T = 20.147000 C 01:41:44 Temperature Measurement, Probe Number = 1, T = 20.036000 C 01:41:45 Temperature Measurement, Probe Number = 2, T = 20.005000 C 01:41:45 Temperature Measurement, Probe Number = 3, T = 19.995000 C 01:41:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 01:41:46 Integrated Voltage Measurement... 01:42:05 Voltage Offset Correction: v_off_ini = -0.000000021 V, v_off_fin = 0.000005699 V 01:42:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420773 Vs 01:42:05 Integrated Voltage Measurement... 01:42:24 Voltage Offset Correction: v_off_ini = 0.000004718 V, v_off_fin = -0.000002915 V 01:42:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319587 Vs 01:42:27 Temperature Measurement, Probe Number = 0, T = 20.137000 C 01:42:28 Temperature Measurement, Probe Number = 1, T = 20.036000 C 01:42:29 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:42:29 Temperature Measurement, Probe Number = 3, T = 19.993000 C 01:42:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:42:29 Integrated Voltage Measurement... 01:42:49 Voltage Offset Correction: v_off_ini = 0.000001117 V, v_off_fin = 0.000005598 V 01:42:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175426480 Vs 01:42:49 Integrated Voltage Measurement... 01:43:08 Voltage Offset Correction: v_off_ini = 0.000004800 V, v_off_fin = -0.000002459 V 01:43:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313502 Vs 01:43:11 Temperature Measurement, Probe Number = 0, T = 20.229000 C 01:43:12 Temperature Measurement, Probe Number = 1, T = 20.038000 C 01:43:13 Temperature Measurement, Probe Number = 2, T = 20.006000 C 01:43:13 Temperature Measurement, Probe Number = 3, T = 19.995000 C 01:43:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 01:43:14 Integrated Voltage Measurement... 01:43:33 Voltage Offset Correction: v_off_ini = 0.000001441 V, v_off_fin = 0.000005993 V 01:43:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425648 Vs 01:43:33 Integrated Voltage Measurement... 01:43:53 Voltage Offset Correction: v_off_ini = 0.000004966 V, v_off_fin = -0.000002248 V 01:43:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319108 Vs 01:43:56 Temperature Measurement, Probe Number = 0, T = 20.284000 C 01:43:56 Temperature Measurement, Probe Number = 1, T = 20.035000 C 01:43:57 Temperature Measurement, Probe Number = 2, T = 20.000000 C 01:43:58 Temperature Measurement, Probe Number = 3, T = 19.992000 C 01:43:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:43:58 Integrated Voltage Measurement... 01:44:17 Voltage Offset Correction: v_off_ini = 0.000000725 V, v_off_fin = 0.000005325 V 01:44:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424637 Vs 01:44:17 Integrated Voltage Measurement... 01:44:37 Voltage Offset Correction: v_off_ini = 0.000004521 V, v_off_fin = -0.000002268 V 01:44:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319830 Vs 01:44:40 Temperature Measurement, Probe Number = 0, T = 20.264000 C 01:44:40 Temperature Measurement, Probe Number = 1, T = 20.034000 C 01:44:41 Temperature Measurement, Probe Number = 2, T = 20.001000 C 01:44:42 Temperature Measurement, Probe Number = 3, T = 19.989000 C 01:44:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 01:44:42 Integrated Voltage Measurement... 01:45:01 Voltage Offset Correction: v_off_ini = 0.000001130 V, v_off_fin = 0.000005431 V 01:45:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420475 Vs 01:45:02 Integrated Voltage Measurement... 01:45:21 Voltage Offset Correction: v_off_ini = 0.000004312 V, v_off_fin = -0.000002286 V 01:45:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318998 Vs 01:45:24 Temperature Measurement, Probe Number = 0, T = 20.240000 C 01:45:25 Temperature Measurement, Probe Number = 1, T = 20.035000 C 01:45:25 Temperature Measurement, Probe Number = 2, T = 20.003000 C 01:45:26 Temperature Measurement, Probe Number = 3, T = 19.996000 C 01:45:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 01:45:26 Integrated Voltage Measurement... 01:45:45 Voltage Offset Correction: v_off_ini = 0.000000757 V, v_off_fin = 0.000005487 V 01:45:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420867 Vs 01:45:45 Integrated Voltage Measurement... 01:46:05 Voltage Offset Correction: v_off_ini = 0.000004531 V, v_off_fin = -0.000002337 V 01:46:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318744 Vs 01:46:08 Temperature Measurement, Probe Number = 0, T = 20.225000 C 01:46:09 Temperature Measurement, Probe Number = 1, T = 20.037000 C 01:46:09 Temperature Measurement, Probe Number = 2, T = 20.004000 C 01:46:10 Temperature Measurement, Probe Number = 3, T = 19.996000 C 01:46:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 01:46:10 Integrated Voltage Measurement... 01:46:29 Voltage Offset Correction: v_off_ini = 0.000000605 V, v_off_fin = 0.000005380 V 01:46:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418216 Vs 01:46:29 Integrated Voltage Measurement... 01:46:49 Voltage Offset Correction: v_off_ini = 0.000004321 V, v_off_fin = -0.000003194 V 01:46:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175328400 Vs 02:16:52 Temperature Measurement, Probe Number = 0, T = 20.308000 C 02:16:53 Temperature Measurement, Probe Number = 1, T = 20.036000 C 02:16:53 Temperature Measurement, Probe Number = 2, T = 20.002000 C 02:16:54 Temperature Measurement, Probe Number = 3, T = 19.993000 C 02:16:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:16:54 Integrated Voltage Measurement... 02:17:13 Voltage Offset Correction: v_off_ini = 0.000003611 V, v_off_fin = 0.000006052 V 02:17:13 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175517350 Vs 02:17:13 Integrated Voltage Measurement... 02:17:33 Voltage Offset Correction: v_off_ini = 0.000005117 V, v_off_fin = -0.000003132 V 02:17:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315474 Vs 02:17:35 Temperature Measurement, Probe Number = 0, T = 20.342000 C 02:17:36 Temperature Measurement, Probe Number = 1, T = 20.037000 C 02:17:37 Temperature Measurement, Probe Number = 2, T = 20.005000 C 02:17:37 Temperature Measurement, Probe Number = 3, T = 19.992000 C 02:17:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:17:38 Integrated Voltage Measurement... 02:17:57 Voltage Offset Correction: v_off_ini = 0.000001419 V, v_off_fin = 0.000005782 V 02:17:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426040 Vs 02:17:57 Integrated Voltage Measurement... 02:18:17 Voltage Offset Correction: v_off_ini = 0.000004851 V, v_off_fin = -0.000002485 V 02:18:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318005 Vs 02:18:20 Temperature Measurement, Probe Number = 0, T = 20.302000 C 02:18:20 Temperature Measurement, Probe Number = 1, T = 20.038000 C 02:18:21 Temperature Measurement, Probe Number = 2, T = 20.004000 C 02:18:22 Temperature Measurement, Probe Number = 3, T = 19.995000 C 02:18:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 02:18:22 Integrated Voltage Measurement... 02:18:41 Voltage Offset Correction: v_off_ini = 0.000000881 V, v_off_fin = 0.000005690 V 02:18:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426067 Vs 02:18:41 Integrated Voltage Measurement... 02:19:00 Voltage Offset Correction: v_off_ini = 0.000005073 V, v_off_fin = -0.000002999 V 02:19:00 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309928 Vs 02:19:03 Temperature Measurement, Probe Number = 0, T = 20.299000 C 02:19:04 Temperature Measurement, Probe Number = 1, T = 20.038000 C 02:19:04 Temperature Measurement, Probe Number = 2, T = 20.004000 C 02:19:05 Temperature Measurement, Probe Number = 3, T = 19.995000 C 02:19:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 02:19:05 Integrated Voltage Measurement... 02:19:24 Voltage Offset Correction: v_off_ini = 0.000001690 V, v_off_fin = 0.000005954 V 02:19:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431609 Vs 02:19:24 Integrated Voltage Measurement... 02:19:44 Voltage Offset Correction: v_off_ini = 0.000005329 V, v_off_fin = -0.000002750 V 02:19:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317006 Vs 02:19:47 Temperature Measurement, Probe Number = 0, T = 20.269000 C 02:19:47 Temperature Measurement, Probe Number = 1, T = 20.036000 C 02:19:48 Temperature Measurement, Probe Number = 2, T = 20.004000 C 02:19:49 Temperature Measurement, Probe Number = 3, T = 19.998000 C 02:19:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 20.00 02:19:49 Integrated Voltage Measurement... 02:20:08 Voltage Offset Correction: v_off_ini = 0.000000916 V, v_off_fin = 0.000005401 V 02:20:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425699 Vs 02:20:08 Integrated Voltage Measurement... 02:20:27 Voltage Offset Correction: v_off_ini = 0.000004934 V, v_off_fin = -0.000002525 V 02:20:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313546 Vs 02:20:30 Temperature Measurement, Probe Number = 0, T = 20.237000 C 02:20:31 Temperature Measurement, Probe Number = 1, T = 20.034000 C 02:20:31 Temperature Measurement, Probe Number = 2, T = 20.000000 C 02:20:32 Temperature Measurement, Probe Number = 3, T = 19.993000 C 02:20:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:20:32 Integrated Voltage Measurement... 02:20:51 Voltage Offset Correction: v_off_ini = 0.000001216 V, v_off_fin = 0.000005406 V 02:20:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431585 Vs 02:20:52 Integrated Voltage Measurement... 02:21:11 Voltage Offset Correction: v_off_ini = 0.000005060 V, v_off_fin = -0.000002462 V 02:21:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314599 Vs 02:21:14 Temperature Measurement, Probe Number = 0, T = 20.235000 C 02:21:14 Temperature Measurement, Probe Number = 1, T = 20.034000 C 02:21:15 Temperature Measurement, Probe Number = 2, T = 20.000000 C 02:21:16 Temperature Measurement, Probe Number = 3, T = 19.994000 C 02:21:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:21:16 Integrated Voltage Measurement... 02:21:35 Voltage Offset Correction: v_off_ini = 0.000000548 V, v_off_fin = 0.000005513 V 02:21:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430239 Vs 02:21:36 Integrated Voltage Measurement... 02:21:55 Voltage Offset Correction: v_off_ini = 0.000004921 V, v_off_fin = -0.000002936 V 02:21:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326980 Vs 02:21:58 Temperature Measurement, Probe Number = 0, T = 20.221000 C 02:21:59 Temperature Measurement, Probe Number = 1, T = 20.034000 C 02:21:59 Temperature Measurement, Probe Number = 2, T = 20.000000 C 02:22:00 Temperature Measurement, Probe Number = 3, T = 19.991000 C 02:22:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:22:00 Integrated Voltage Measurement... 02:22:19 Voltage Offset Correction: v_off_ini = 0.000001186 V, v_off_fin = 0.000005336 V 02:22:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426759 Vs 02:22:20 Integrated Voltage Measurement... 02:22:39 Voltage Offset Correction: v_off_ini = 0.000004885 V, v_off_fin = -0.000002150 V 02:22:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319158 Vs 02:22:42 Temperature Measurement, Probe Number = 0, T = 20.225000 C 02:22:43 Temperature Measurement, Probe Number = 1, T = 20.037000 C 02:22:43 Temperature Measurement, Probe Number = 2, T = 20.004000 C 02:22:44 Temperature Measurement, Probe Number = 3, T = 19.992000 C 02:22:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:22:44 Integrated Voltage Measurement... 02:23:03 Voltage Offset Correction: v_off_ini = 0.000001765 V, v_off_fin = 0.000006111 V 02:23:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427857 Vs 02:23:03 Integrated Voltage Measurement... 02:23:23 Voltage Offset Correction: v_off_ini = 0.000005503 V, v_off_fin = -0.000002380 V 02:23:23 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175311314 Vs 02:23:25 Temperature Measurement, Probe Number = 0, T = 20.289000 C 02:23:26 Temperature Measurement, Probe Number = 1, T = 20.037000 C 02:23:27 Temperature Measurement, Probe Number = 2, T = 20.007000 C 02:23:27 Temperature Measurement, Probe Number = 3, T = 19.993000 C 02:23:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 02:23:27 Integrated Voltage Measurement... 02:23:47 Voltage Offset Correction: v_off_ini = 0.000001496 V, v_off_fin = 0.000005422 V 02:23:47 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175429619 Vs 02:23:47 Integrated Voltage Measurement... 02:24:06 Voltage Offset Correction: v_off_ini = 0.000004519 V, v_off_fin = -0.000003275 V 02:24:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175336192 Vs 02:54:09 Temperature Measurement, Probe Number = 0, T = 20.207000 C 02:54:10 Temperature Measurement, Probe Number = 1, T = 20.030000 C 02:54:11 Temperature Measurement, Probe Number = 2, T = 19.999000 C 02:54:11 Temperature Measurement, Probe Number = 3, T = 19.989000 C 02:54:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:54:11 Integrated Voltage Measurement... 02:54:31 Voltage Offset Correction: v_off_ini = 0.000003957 V, v_off_fin = 0.000005786 V 02:54:31 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175521287 Vs 02:54:31 Integrated Voltage Measurement... 02:54:50 Voltage Offset Correction: v_off_ini = 0.000004758 V, v_off_fin = -0.000001799 V 02:54:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309462 Vs 02:54:53 Temperature Measurement, Probe Number = 0, T = 20.282000 C 02:54:53 Temperature Measurement, Probe Number = 1, T = 20.030000 C 02:54:54 Temperature Measurement, Probe Number = 2, T = 19.998000 C 02:54:55 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:54:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:54:55 Integrated Voltage Measurement... 02:55:14 Voltage Offset Correction: v_off_ini = 0.000001362 V, v_off_fin = 0.000005805 V 02:55:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427066 Vs 02:55:15 Integrated Voltage Measurement... 02:55:33 Voltage Offset Correction: v_off_ini = 0.000005117 V, v_off_fin = -0.000002048 V 02:55:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306491 Vs 02:55:36 Temperature Measurement, Probe Number = 0, T = 20.227000 C 02:55:37 Temperature Measurement, Probe Number = 1, T = 20.028000 C 02:55:38 Temperature Measurement, Probe Number = 2, T = 19.997000 C 02:55:38 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:55:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:55:39 Integrated Voltage Measurement... 02:55:58 Voltage Offset Correction: v_off_ini = 0.000000192 V, v_off_fin = 0.000005532 V 02:55:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433548 Vs 02:55:58 Integrated Voltage Measurement... 02:56:17 Voltage Offset Correction: v_off_ini = 0.000005317 V, v_off_fin = -0.000002671 V 02:56:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311717 Vs 02:56:20 Temperature Measurement, Probe Number = 0, T = 20.215000 C 02:56:21 Temperature Measurement, Probe Number = 1, T = 20.028000 C 02:56:21 Temperature Measurement, Probe Number = 2, T = 20.000000 C 02:56:22 Temperature Measurement, Probe Number = 3, T = 19.991000 C 02:56:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:56:22 Integrated Voltage Measurement... 02:56:42 Voltage Offset Correction: v_off_ini = 0.000001002 V, v_off_fin = 0.000005304 V 02:56:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433356 Vs 02:56:43 Integrated Voltage Measurement... 02:57:02 Voltage Offset Correction: v_off_ini = 0.000004663 V, v_off_fin = -0.000002211 V 02:57:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310938 Vs 02:57:04 Temperature Measurement, Probe Number = 0, T = 20.202000 C 02:57:05 Temperature Measurement, Probe Number = 1, T = 20.030000 C 02:57:06 Temperature Measurement, Probe Number = 2, T = 19.998000 C 02:57:06 Temperature Measurement, Probe Number = 3, T = 19.988000 C 02:57:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:57:07 Integrated Voltage Measurement... 02:57:26 Voltage Offset Correction: v_off_ini = 0.000001155 V, v_off_fin = 0.000006031 V 02:57:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427183 Vs 02:57:26 Integrated Voltage Measurement... 02:57:45 Voltage Offset Correction: v_off_ini = 0.000005021 V, v_off_fin = -0.000002114 V 02:57:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316065 Vs 02:57:48 Temperature Measurement, Probe Number = 0, T = 20.247000 C 02:57:49 Temperature Measurement, Probe Number = 1, T = 20.032000 C 02:57:49 Temperature Measurement, Probe Number = 2, T = 19.999000 C 02:57:50 Temperature Measurement, Probe Number = 3, T = 19.990000 C 02:57:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:57:50 Integrated Voltage Measurement... 02:58:09 Voltage Offset Correction: v_off_ini = 0.000001132 V, v_off_fin = 0.000005925 V 02:58:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427789 Vs 02:58:10 Integrated Voltage Measurement... 02:58:29 Voltage Offset Correction: v_off_ini = 0.000005051 V, v_off_fin = -0.000002419 V 02:58:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309336 Vs 02:58:32 Temperature Measurement, Probe Number = 0, T = 20.234000 C 02:58:32 Temperature Measurement, Probe Number = 1, T = 20.030000 C 02:58:33 Temperature Measurement, Probe Number = 2, T = 20.000000 C 02:58:34 Temperature Measurement, Probe Number = 3, T = 19.991000 C 02:58:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:58:34 Integrated Voltage Measurement... 02:58:54 Voltage Offset Correction: v_off_ini = 0.000001329 V, v_off_fin = 0.000005515 V 02:58:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427432 Vs 02:58:54 Integrated Voltage Measurement... 02:59:14 Voltage Offset Correction: v_off_ini = 0.000004481 V, v_off_fin = -0.000001927 V 02:59:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318014 Vs 02:59:16 Temperature Measurement, Probe Number = 0, T = 20.217000 C 02:59:17 Temperature Measurement, Probe Number = 1, T = 20.031000 C 02:59:18 Temperature Measurement, Probe Number = 2, T = 20.002000 C 02:59:18 Temperature Measurement, Probe Number = 3, T = 19.989000 C 02:59:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 02:59:19 Integrated Voltage Measurement... 02:59:38 Voltage Offset Correction: v_off_ini = 0.000001210 V, v_off_fin = 0.000005577 V 02:59:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423532 Vs 02:59:38 Integrated Voltage Measurement... 02:59:58 Voltage Offset Correction: v_off_ini = 0.000004841 V, v_off_fin = -0.000001947 V 02:59:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321237 Vs 03:00:00 Temperature Measurement, Probe Number = 0, T = 20.262000 C 03:00:01 Temperature Measurement, Probe Number = 1, T = 20.034000 C 03:00:02 Temperature Measurement, Probe Number = 2, T = 20.005000 C 03:00:02 Temperature Measurement, Probe Number = 3, T = 19.988000 C 03:00:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 03:00:03 Integrated Voltage Measurement... 03:00:22 Voltage Offset Correction: v_off_ini = 0.000001501 V, v_off_fin = 0.000006276 V 03:00:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430863 Vs 03:00:22 Integrated Voltage Measurement... 03:00:42 Voltage Offset Correction: v_off_ini = 0.000005090 V, v_off_fin = -0.000002496 V 03:00:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321573 Vs 03:00:45 Temperature Measurement, Probe Number = 0, T = 20.260000 C 03:00:45 Temperature Measurement, Probe Number = 1, T = 20.032000 C 03:00:46 Temperature Measurement, Probe Number = 2, T = 20.003000 C 03:00:47 Temperature Measurement, Probe Number = 3, T = 19.990000 C 03:00:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 03:00:47 Integrated Voltage Measurement... 03:01:06 Voltage Offset Correction: v_off_ini = 0.000000852 V, v_off_fin = 0.000005426 V 03:01:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423858 Vs 03:01:06 Integrated Voltage Measurement... 03:01:26 Voltage Offset Correction: v_off_ini = 0.000004535 V, v_off_fin = -0.000002655 V 03:01:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319331 Vs 03:31:29 Temperature Measurement, Probe Number = 0, T = 20.213000 C 03:31:29 Temperature Measurement, Probe Number = 1, T = 20.020000 C 03:31:30 Temperature Measurement, Probe Number = 2, T = 19.992000 C 03:31:31 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:31:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:31:31 Integrated Voltage Measurement... 03:31:50 Voltage Offset Correction: v_off_ini = 0.000003466 V, v_off_fin = 0.000005252 V 03:31:50 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175515823 Vs 03:31:50 Integrated Voltage Measurement... 03:32:09 Voltage Offset Correction: v_off_ini = 0.000004349 V, v_off_fin = -0.000002507 V 03:32:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316846 Vs 03:32:12 Temperature Measurement, Probe Number = 0, T = 20.218000 C 03:32:13 Temperature Measurement, Probe Number = 1, T = 20.025000 C 03:32:13 Temperature Measurement, Probe Number = 2, T = 19.995000 C 03:32:14 Temperature Measurement, Probe Number = 3, T = 19.984000 C 03:32:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 03:32:14 Integrated Voltage Measurement... 03:32:33 Voltage Offset Correction: v_off_ini = 0.000000519 V, v_off_fin = 0.000005702 V 03:32:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426460 Vs 03:32:33 Integrated Voltage Measurement... 03:32:53 Voltage Offset Correction: v_off_ini = 0.000004985 V, v_off_fin = -0.000001460 V 03:32:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313237 Vs 03:32:55 Temperature Measurement, Probe Number = 0, T = 20.209000 C 03:32:56 Temperature Measurement, Probe Number = 1, T = 20.027000 C 03:32:57 Temperature Measurement, Probe Number = 2, T = 19.993000 C 03:32:57 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:32:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:32:58 Integrated Voltage Measurement... 03:33:17 Voltage Offset Correction: v_off_ini = 0.000000794 V, v_off_fin = 0.000005757 V 03:33:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431588 Vs 03:33:17 Integrated Voltage Measurement... 03:33:37 Voltage Offset Correction: v_off_ini = 0.000004760 V, v_off_fin = -0.000001556 V 03:33:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175311486 Vs 03:33:39 Temperature Measurement, Probe Number = 0, T = 20.206000 C 03:33:40 Temperature Measurement, Probe Number = 1, T = 20.025000 C 03:33:41 Temperature Measurement, Probe Number = 2, T = 19.994000 C 03:33:41 Temperature Measurement, Probe Number = 3, T = 19.985000 C 03:33:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:33:42 Integrated Voltage Measurement... 03:34:01 Voltage Offset Correction: v_off_ini = 0.000001310 V, v_off_fin = 0.000006218 V 03:34:01 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422817 Vs 03:34:01 Integrated Voltage Measurement... 03:34:20 Voltage Offset Correction: v_off_ini = 0.000005043 V, v_off_fin = -0.000002455 V 03:34:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313886 Vs 03:34:23 Temperature Measurement, Probe Number = 0, T = 20.210000 C 03:34:24 Temperature Measurement, Probe Number = 1, T = 20.024000 C 03:34:24 Temperature Measurement, Probe Number = 2, T = 19.993000 C 03:34:25 Temperature Measurement, Probe Number = 3, T = 19.987000 C 03:34:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.99 03:34:25 Integrated Voltage Measurement... 03:34:44 Voltage Offset Correction: v_off_ini = 0.000001255 V, v_off_fin = 0.000005979 V 03:34:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438690 Vs 03:34:45 Integrated Voltage Measurement... 03:35:04 Voltage Offset Correction: v_off_ini = 0.000004984 V, v_off_fin = -0.000002055 V 03:35:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318326 Vs 03:35:07 Temperature Measurement, Probe Number = 0, T = 20.190000 C 03:35:08 Temperature Measurement, Probe Number = 1, T = 20.025000 C 03:35:08 Temperature Measurement, Probe Number = 2, T = 19.992000 C 03:35:09 Temperature Measurement, Probe Number = 3, T = 19.983000 C 03:35:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:35:09 Integrated Voltage Measurement... 03:35:28 Voltage Offset Correction: v_off_ini = 0.000001530 V, v_off_fin = 0.000005651 V 03:35:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429090 Vs 03:35:29 Integrated Voltage Measurement... 03:35:48 Voltage Offset Correction: v_off_ini = 0.000005241 V, v_off_fin = -0.000002333 V 03:35:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322048 Vs 03:35:51 Temperature Measurement, Probe Number = 0, T = 20.182000 C 03:35:52 Temperature Measurement, Probe Number = 1, T = 20.024000 C 03:35:52 Temperature Measurement, Probe Number = 2, T = 19.989000 C 03:35:53 Temperature Measurement, Probe Number = 3, T = 19.980000 C 03:35:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:35:53 Integrated Voltage Measurement... 03:36:12 Voltage Offset Correction: v_off_ini = 0.000001283 V, v_off_fin = 0.000006034 V 03:36:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434025 Vs 03:36:12 Integrated Voltage Measurement... 03:36:31 Voltage Offset Correction: v_off_ini = 0.000004963 V, v_off_fin = -0.000002521 V 03:36:32 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175315639 Vs 03:36:34 Temperature Measurement, Probe Number = 0, T = 20.176000 C 03:36:35 Temperature Measurement, Probe Number = 1, T = 20.020000 C 03:36:36 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:36:36 Temperature Measurement, Probe Number = 3, T = 19.979000 C 03:36:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 03:36:36 Integrated Voltage Measurement... 03:36:55 Voltage Offset Correction: v_off_ini = 0.000001200 V, v_off_fin = 0.000005581 V 03:36:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434406 Vs 03:36:56 Integrated Voltage Measurement... 03:37:15 Voltage Offset Correction: v_off_ini = 0.000005154 V, v_off_fin = -0.000001960 V 03:37:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323455 Vs 03:37:18 Temperature Measurement, Probe Number = 0, T = 20.141000 C 03:37:19 Temperature Measurement, Probe Number = 1, T = 20.022000 C 03:37:19 Temperature Measurement, Probe Number = 2, T = 19.985000 C 03:37:20 Temperature Measurement, Probe Number = 3, T = 19.979000 C 03:37:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 03:37:20 Integrated Voltage Measurement... 03:37:40 Voltage Offset Correction: v_off_ini = 0.000000995 V, v_off_fin = 0.000005125 V 03:37:40 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425054 Vs 03:37:40 Integrated Voltage Measurement... 03:37:59 Voltage Offset Correction: v_off_ini = 0.000004287 V, v_off_fin = -0.000002885 V 03:37:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316090 Vs 03:38:02 Temperature Measurement, Probe Number = 0, T = 20.162000 C 03:38:03 Temperature Measurement, Probe Number = 1, T = 20.026000 C 03:38:03 Temperature Measurement, Probe Number = 2, T = 19.989000 C 03:38:04 Temperature Measurement, Probe Number = 3, T = 19.980000 C 03:38:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 03:38:04 Integrated Voltage Measurement... 03:38:23 Voltage Offset Correction: v_off_ini = 0.000000560 V, v_off_fin = 0.000005834 V 03:38:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427318 Vs 03:38:24 Integrated Voltage Measurement... 03:38:43 Voltage Offset Correction: v_off_ini = 0.000004591 V, v_off_fin = -0.000002442 V 03:38:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322078 Vs 04:08:46 Temperature Measurement, Probe Number = 0, T = 20.183000 C 04:08:46 Temperature Measurement, Probe Number = 1, T = 20.020000 C 04:08:47 Temperature Measurement, Probe Number = 2, T = 19.987000 C 04:08:48 Temperature Measurement, Probe Number = 3, T = 19.980000 C 04:08:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:08:48 Integrated Voltage Measurement... 04:09:07 Voltage Offset Correction: v_off_ini = 0.000003423 V, v_off_fin = 0.000005490 V 04:09:08 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175518339 Vs 04:09:08 Integrated Voltage Measurement... 04:09:27 Voltage Offset Correction: v_off_ini = 0.000004795 V, v_off_fin = -0.000002010 V 04:09:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315692 Vs 04:09:30 Temperature Measurement, Probe Number = 0, T = 20.199000 C 04:09:31 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:09:31 Temperature Measurement, Probe Number = 2, T = 19.987000 C 04:09:32 Temperature Measurement, Probe Number = 3, T = 19.981000 C 04:09:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:09:32 Integrated Voltage Measurement... 04:09:51 Voltage Offset Correction: v_off_ini = 0.000001638 V, v_off_fin = 0.000006512 V 04:09:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436019 Vs 04:09:52 Integrated Voltage Measurement... 04:10:10 Voltage Offset Correction: v_off_ini = 0.000005805 V, v_off_fin = -0.000001755 V 04:10:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306770 Vs 04:10:13 Temperature Measurement, Probe Number = 0, T = 20.180000 C 04:10:14 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:10:15 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:10:15 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:10:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 04:10:15 Integrated Voltage Measurement... 04:10:34 Voltage Offset Correction: v_off_ini = 0.000001224 V, v_off_fin = 0.000006031 V 04:10:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439055 Vs 04:10:35 Integrated Voltage Measurement... 04:10:54 Voltage Offset Correction: v_off_ini = 0.000004978 V, v_off_fin = -0.000002527 V 04:10:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321419 Vs 04:10:57 Temperature Measurement, Probe Number = 0, T = 20.154000 C 04:10:58 Temperature Measurement, Probe Number = 1, T = 20.017000 C 04:10:58 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:10:59 Temperature Measurement, Probe Number = 3, T = 19.976000 C 04:10:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 04:10:59 Integrated Voltage Measurement... 04:11:19 Voltage Offset Correction: v_off_ini = 0.000001676 V, v_off_fin = 0.000005660 V 04:11:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434788 Vs 04:11:19 Integrated Voltage Measurement... 04:11:38 Voltage Offset Correction: v_off_ini = 0.000004413 V, v_off_fin = -0.000002444 V 04:11:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315562 Vs 04:11:41 Temperature Measurement, Probe Number = 0, T = 20.156000 C 04:11:42 Temperature Measurement, Probe Number = 1, T = 20.018000 C 04:11:43 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:11:43 Temperature Measurement, Probe Number = 3, T = 19.975000 C 04:11:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:11:43 Integrated Voltage Measurement... 04:12:02 Voltage Offset Correction: v_off_ini = 0.000001409 V, v_off_fin = 0.000005686 V 04:12:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431126 Vs 04:12:03 Integrated Voltage Measurement... 04:12:22 Voltage Offset Correction: v_off_ini = 0.000005514 V, v_off_fin = -0.000002136 V 04:12:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307469 Vs 04:12:25 Temperature Measurement, Probe Number = 0, T = 20.200000 C 04:12:25 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:12:26 Temperature Measurement, Probe Number = 2, T = 19.989000 C 04:12:27 Temperature Measurement, Probe Number = 3, T = 19.982000 C 04:12:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:12:27 Integrated Voltage Measurement... 04:12:47 Voltage Offset Correction: v_off_ini = 0.000001194 V, v_off_fin = 0.000005305 V 04:12:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431342 Vs 04:12:48 Integrated Voltage Measurement... 04:13:07 Voltage Offset Correction: v_off_ini = 0.000004268 V, v_off_fin = -0.000003211 V 04:13:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314770 Vs 04:13:10 Temperature Measurement, Probe Number = 0, T = 20.237000 C 04:13:10 Temperature Measurement, Probe Number = 1, T = 20.021000 C 04:13:11 Temperature Measurement, Probe Number = 2, T = 19.986000 C 04:13:11 Temperature Measurement, Probe Number = 3, T = 19.978000 C 04:13:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:13:12 Integrated Voltage Measurement... 04:13:31 Voltage Offset Correction: v_off_ini = 0.000001297 V, v_off_fin = 0.000005533 V 04:13:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434540 Vs 04:13:31 Integrated Voltage Measurement... 04:13:50 Voltage Offset Correction: v_off_ini = 0.000004464 V, v_off_fin = -0.000002402 V 04:13:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318851 Vs 04:13:53 Temperature Measurement, Probe Number = 0, T = 20.277000 C 04:13:54 Temperature Measurement, Probe Number = 1, T = 20.021000 C 04:13:54 Temperature Measurement, Probe Number = 2, T = 19.989000 C 04:13:55 Temperature Measurement, Probe Number = 3, T = 19.981000 C 04:13:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:13:55 Integrated Voltage Measurement... 04:14:14 Voltage Offset Correction: v_off_ini = 0.000001334 V, v_off_fin = 0.000005878 V 04:14:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432298 Vs 04:14:15 Integrated Voltage Measurement... 04:14:34 Voltage Offset Correction: v_off_ini = 0.000004934 V, v_off_fin = -0.000001883 V 04:14:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317081 Vs 04:14:37 Temperature Measurement, Probe Number = 0, T = 20.279000 C 04:14:37 Temperature Measurement, Probe Number = 1, T = 20.022000 C 04:14:38 Temperature Measurement, Probe Number = 2, T = 19.992000 C 04:14:38 Temperature Measurement, Probe Number = 3, T = 19.981000 C 04:14:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:14:39 Integrated Voltage Measurement... 04:14:58 Voltage Offset Correction: v_off_ini = 0.000001279 V, v_off_fin = 0.000005815 V 04:14:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436601 Vs 04:14:58 Integrated Voltage Measurement... 04:15:18 Voltage Offset Correction: v_off_ini = 0.000004965 V, v_off_fin = -0.000002340 V 04:15:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319182 Vs 04:15:21 Temperature Measurement, Probe Number = 0, T = 20.278000 C 04:15:21 Temperature Measurement, Probe Number = 1, T = 20.020000 C 04:15:22 Temperature Measurement, Probe Number = 2, T = 19.988000 C 04:15:23 Temperature Measurement, Probe Number = 3, T = 19.981000 C 04:15:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 04:15:23 Integrated Voltage Measurement... 04:15:42 Voltage Offset Correction: v_off_ini = 0.000001443 V, v_off_fin = 0.000006290 V 04:15:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434112 Vs 04:15:42 Integrated Voltage Measurement... 04:16:01 Voltage Offset Correction: v_off_ini = 0.000005523 V, v_off_fin = -0.000002154 V 04:16:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312525 Vs 04:46:04 Temperature Measurement, Probe Number = 0, T = 20.185000 C 04:46:05 Temperature Measurement, Probe Number = 1, T = 20.011000 C 04:46:05 Temperature Measurement, Probe Number = 2, T = 19.979000 C 04:46:06 Temperature Measurement, Probe Number = 3, T = 19.971000 C 04:46:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:46:06 Integrated Voltage Measurement... 04:46:26 Voltage Offset Correction: v_off_ini = 0.000003596 V, v_off_fin = 0.000005615 V 04:46:26 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175528215 Vs 04:46:26 Integrated Voltage Measurement... 04:46:45 Voltage Offset Correction: v_off_ini = 0.000005141 V, v_off_fin = -0.000003152 V 04:46:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313441 Vs 04:46:48 Temperature Measurement, Probe Number = 0, T = 20.131000 C 04:46:48 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:46:49 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:46:50 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:46:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:46:50 Integrated Voltage Measurement... 04:47:09 Voltage Offset Correction: v_off_ini = 0.000000848 V, v_off_fin = 0.000005301 V 04:47:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430245 Vs 04:47:09 Integrated Voltage Measurement... 04:47:29 Voltage Offset Correction: v_off_ini = 0.000004718 V, v_off_fin = -0.000002401 V 04:47:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325495 Vs 04:47:31 Temperature Measurement, Probe Number = 0, T = 20.173000 C 04:47:32 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:47:33 Temperature Measurement, Probe Number = 2, T = 19.983000 C 04:47:33 Temperature Measurement, Probe Number = 3, T = 19.975000 C 04:47:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 04:47:34 Integrated Voltage Measurement... 04:47:53 Voltage Offset Correction: v_off_ini = 0.000001647 V, v_off_fin = 0.000005987 V 04:47:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437731 Vs 04:47:53 Integrated Voltage Measurement... 04:48:13 Voltage Offset Correction: v_off_ini = 0.000005198 V, v_off_fin = -0.000002091 V 04:48:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317238 Vs 04:48:15 Temperature Measurement, Probe Number = 0, T = 20.172000 C 04:48:16 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:48:17 Temperature Measurement, Probe Number = 2, T = 19.982000 C 04:48:17 Temperature Measurement, Probe Number = 3, T = 19.974000 C 04:48:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:48:18 Integrated Voltage Measurement... 04:48:37 Voltage Offset Correction: v_off_ini = 0.000001282 V, v_off_fin = 0.000005417 V 04:48:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175435319 Vs 04:48:37 Integrated Voltage Measurement... 04:48:57 Voltage Offset Correction: v_off_ini = 0.000004496 V, v_off_fin = -0.000002267 V 04:48:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175324347 Vs 04:49:00 Temperature Measurement, Probe Number = 0, T = 20.164000 C 04:49:00 Temperature Measurement, Probe Number = 1, T = 20.012000 C 04:49:01 Temperature Measurement, Probe Number = 2, T = 19.979000 C 04:49:01 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:49:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:49:02 Integrated Voltage Measurement... 04:49:21 Voltage Offset Correction: v_off_ini = 0.000000601 V, v_off_fin = 0.000005433 V 04:49:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431187 Vs 04:49:21 Integrated Voltage Measurement... 04:49:41 Voltage Offset Correction: v_off_ini = 0.000004556 V, v_off_fin = -0.000002972 V 04:49:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325027 Vs 04:49:44 Temperature Measurement, Probe Number = 0, T = 20.191000 C 04:49:44 Temperature Measurement, Probe Number = 1, T = 20.013000 C 04:49:45 Temperature Measurement, Probe Number = 2, T = 19.980000 C 04:49:46 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:49:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:49:46 Integrated Voltage Measurement... 04:50:05 Voltage Offset Correction: v_off_ini = 0.000000892 V, v_off_fin = 0.000005814 V 04:50:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429855 Vs 04:50:05 Integrated Voltage Measurement... 04:50:25 Voltage Offset Correction: v_off_ini = 0.000005130 V, v_off_fin = -0.000002174 V 04:50:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320038 Vs 04:50:27 Temperature Measurement, Probe Number = 0, T = 20.172000 C 04:50:28 Temperature Measurement, Probe Number = 1, T = 20.015000 C 04:50:29 Temperature Measurement, Probe Number = 2, T = 19.983000 C 04:50:29 Temperature Measurement, Probe Number = 3, T = 19.976000 C 04:50:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 04:50:29 Integrated Voltage Measurement... 04:50:49 Voltage Offset Correction: v_off_ini = 0.000001968 V, v_off_fin = 0.000005926 V 04:50:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438131 Vs 04:50:49 Integrated Voltage Measurement... 04:51:08 Voltage Offset Correction: v_off_ini = 0.000005210 V, v_off_fin = -0.000001839 V 04:51:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315680 Vs 04:51:11 Temperature Measurement, Probe Number = 0, T = 20.218000 C 04:51:12 Temperature Measurement, Probe Number = 1, T = 20.019000 C 04:51:12 Temperature Measurement, Probe Number = 2, T = 19.985000 C 04:51:13 Temperature Measurement, Probe Number = 3, T = 19.976000 C 04:51:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 04:51:13 Integrated Voltage Measurement... 04:51:32 Voltage Offset Correction: v_off_ini = 0.000001022 V, v_off_fin = 0.000006141 V 04:51:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432263 Vs 04:51:33 Integrated Voltage Measurement... 04:51:52 Voltage Offset Correction: v_off_ini = 0.000005252 V, v_off_fin = -0.000002134 V 04:51:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321043 Vs 04:51:55 Temperature Measurement, Probe Number = 0, T = 20.194000 C 04:51:55 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:51:56 Temperature Measurement, Probe Number = 2, T = 19.977000 C 04:51:57 Temperature Measurement, Probe Number = 3, T = 19.972000 C 04:51:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:51:57 Integrated Voltage Measurement... 04:52:16 Voltage Offset Correction: v_off_ini = 0.000001675 V, v_off_fin = 0.000006008 V 04:52:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175437685 Vs 04:52:16 Integrated Voltage Measurement... 04:52:35 Voltage Offset Correction: v_off_ini = 0.000005214 V, v_off_fin = -0.000002510 V 04:52:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313985 Vs 04:52:38 Temperature Measurement, Probe Number = 0, T = 20.188000 C 04:52:39 Temperature Measurement, Probe Number = 1, T = 20.016000 C 04:52:40 Temperature Measurement, Probe Number = 2, T = 19.983000 C 04:52:40 Temperature Measurement, Probe Number = 3, T = 19.973000 C 04:52:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 04:52:40 Integrated Voltage Measurement... 04:52:59 Voltage Offset Correction: v_off_ini = 0.000001245 V, v_off_fin = 0.000006325 V 04:53:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438829 Vs 04:53:00 Integrated Voltage Measurement... 04:53:19 Voltage Offset Correction: v_off_ini = 0.000004848 V, v_off_fin = -0.000002173 V 04:53:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318209 Vs 05:23:22 Temperature Measurement, Probe Number = 0, T = 20.238000 C 05:23:23 Temperature Measurement, Probe Number = 1, T = 20.009000 C 05:23:23 Temperature Measurement, Probe Number = 2, T = 19.981000 C 05:23:24 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:23:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:23:24 Integrated Voltage Measurement... 05:23:43 Voltage Offset Correction: v_off_ini = 0.000003479 V, v_off_fin = 0.000005716 V 05:23:44 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175519213 Vs 05:23:44 Integrated Voltage Measurement... 05:24:03 Voltage Offset Correction: v_off_ini = 0.000005274 V, v_off_fin = -0.000001375 V 05:24:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311769 Vs 05:24:06 Temperature Measurement, Probe Number = 0, T = 20.207000 C 05:24:07 Temperature Measurement, Probe Number = 1, T = 20.010000 C 05:24:07 Temperature Measurement, Probe Number = 2, T = 19.979000 C 05:24:08 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:24:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:24:08 Integrated Voltage Measurement... 05:24:27 Voltage Offset Correction: v_off_ini = 0.000001147 V, v_off_fin = 0.000005188 V 05:24:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433022 Vs 05:24:28 Integrated Voltage Measurement... 05:24:47 Voltage Offset Correction: v_off_ini = 0.000004914 V, v_off_fin = -0.000002100 V 05:24:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316695 Vs 05:24:50 Temperature Measurement, Probe Number = 0, T = 20.180000 C 05:24:51 Temperature Measurement, Probe Number = 1, T = 20.008000 C 05:24:51 Temperature Measurement, Probe Number = 2, T = 19.976000 C 05:24:52 Temperature Measurement, Probe Number = 3, T = 19.967000 C 05:24:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:24:52 Integrated Voltage Measurement... 05:25:12 Voltage Offset Correction: v_off_ini = 0.000000847 V, v_off_fin = 0.000005056 V 05:25:12 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175430534 Vs 05:25:12 Integrated Voltage Measurement... 05:25:31 Voltage Offset Correction: v_off_ini = 0.000004047 V, v_off_fin = -0.000003576 V 05:25:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320799 Vs 05:25:34 Temperature Measurement, Probe Number = 0, T = 20.140000 C 05:25:35 Temperature Measurement, Probe Number = 1, T = 20.009000 C 05:25:36 Temperature Measurement, Probe Number = 2, T = 19.976000 C 05:25:36 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:25:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:25:37 Integrated Voltage Measurement... 05:25:56 Voltage Offset Correction: v_off_ini = 0.000000821 V, v_off_fin = 0.000005670 V 05:25:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434968 Vs 05:25:56 Integrated Voltage Measurement... 05:26:15 Voltage Offset Correction: v_off_ini = 0.000004827 V, v_off_fin = -0.000002347 V 05:26:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320840 Vs 05:26:18 Temperature Measurement, Probe Number = 0, T = 20.140000 C 05:26:19 Temperature Measurement, Probe Number = 1, T = 20.011000 C 05:26:19 Temperature Measurement, Probe Number = 2, T = 19.978000 C 05:26:20 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:26:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:26:20 Integrated Voltage Measurement... 05:26:39 Voltage Offset Correction: v_off_ini = 0.000000837 V, v_off_fin = 0.000005910 V 05:26:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433050 Vs 05:26:40 Integrated Voltage Measurement... 05:27:00 Voltage Offset Correction: v_off_ini = 0.000005260 V, v_off_fin = -0.000001684 V 05:27:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175319702 Vs 05:27:02 Temperature Measurement, Probe Number = 0, T = 20.174000 C 05:27:03 Temperature Measurement, Probe Number = 1, T = 20.010000 C 05:27:04 Temperature Measurement, Probe Number = 2, T = 19.975000 C 05:27:04 Temperature Measurement, Probe Number = 3, T = 19.966000 C 05:27:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:27:05 Integrated Voltage Measurement... 05:27:24 Voltage Offset Correction: v_off_ini = 0.000001961 V, v_off_fin = 0.000006521 V 05:27:24 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431647 Vs 05:27:24 Integrated Voltage Measurement... 05:27:43 Voltage Offset Correction: v_off_ini = 0.000005514 V, v_off_fin = -0.000002405 V 05:27:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314722 Vs 05:27:46 Temperature Measurement, Probe Number = 0, T = 20.205000 C 05:27:47 Temperature Measurement, Probe Number = 1, T = 20.011000 C 05:27:48 Temperature Measurement, Probe Number = 2, T = 19.979000 C 05:27:48 Temperature Measurement, Probe Number = 3, T = 19.968000 C 05:27:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:27:48 Integrated Voltage Measurement... 05:28:08 Voltage Offset Correction: v_off_ini = 0.000001126 V, v_off_fin = 0.000005847 V 05:28:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423587 Vs 05:28:08 Integrated Voltage Measurement... 05:28:27 Voltage Offset Correction: v_off_ini = 0.000004653 V, v_off_fin = -0.000002683 V 05:28:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323394 Vs 05:28:30 Temperature Measurement, Probe Number = 0, T = 20.211000 C 05:28:31 Temperature Measurement, Probe Number = 1, T = 20.013000 C 05:28:32 Temperature Measurement, Probe Number = 2, T = 19.982000 C 05:28:32 Temperature Measurement, Probe Number = 3, T = 19.973000 C 05:28:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:28:32 Integrated Voltage Measurement... 05:28:52 Voltage Offset Correction: v_off_ini = 0.000001706 V, v_off_fin = 0.000005226 V 05:28:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430961 Vs 05:28:53 Integrated Voltage Measurement... 05:29:12 Voltage Offset Correction: v_off_ini = 0.000004857 V, v_off_fin = -0.000002575 V 05:29:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306313 Vs 05:29:15 Temperature Measurement, Probe Number = 0, T = 20.221000 C 05:29:15 Temperature Measurement, Probe Number = 1, T = 20.014000 C 05:29:16 Temperature Measurement, Probe Number = 2, T = 19.982000 C 05:29:17 Temperature Measurement, Probe Number = 3, T = 19.971000 C 05:29:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:29:17 Integrated Voltage Measurement... 05:29:37 Voltage Offset Correction: v_off_ini = 0.000001174 V, v_off_fin = 0.000005843 V 05:29:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434405 Vs 05:29:37 Integrated Voltage Measurement... 05:29:57 Voltage Offset Correction: v_off_ini = 0.000005071 V, v_off_fin = -0.000002179 V 05:29:57 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175316803 Vs 05:30:00 Temperature Measurement, Probe Number = 0, T = 20.253000 C 05:30:00 Temperature Measurement, Probe Number = 1, T = 20.013000 C 05:30:01 Temperature Measurement, Probe Number = 2, T = 19.979000 C 05:30:02 Temperature Measurement, Probe Number = 3, T = 19.970000 C 05:30:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 05:30:02 Integrated Voltage Measurement... 05:30:21 Voltage Offset Correction: v_off_ini = 0.000001709 V, v_off_fin = 0.000005698 V 05:30:21 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175428171 Vs 05:30:21 Integrated Voltage Measurement... 05:30:41 Voltage Offset Correction: v_off_ini = 0.000004871 V, v_off_fin = -0.000001692 V 05:30:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315646 Vs 06:00:43 Temperature Measurement, Probe Number = 0, T = 20.091000 C 06:00:44 Temperature Measurement, Probe Number = 1, T = 20.004000 C 06:00:45 Temperature Measurement, Probe Number = 2, T = 19.967000 C 06:00:45 Temperature Measurement, Probe Number = 3, T = 19.960000 C 06:00:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:00:46 Integrated Voltage Measurement... 06:01:05 Voltage Offset Correction: v_off_ini = 0.000003928 V, v_off_fin = 0.000006088 V 06:01:05 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175517996 Vs 06:01:05 Integrated Voltage Measurement... 06:01:24 Voltage Offset Correction: v_off_ini = 0.000004791 V, v_off_fin = -0.000002026 V 06:01:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310031 Vs 06:01:27 Temperature Measurement, Probe Number = 0, T = 20.128000 C 06:01:28 Temperature Measurement, Probe Number = 1, T = 20.005000 C 06:01:29 Temperature Measurement, Probe Number = 2, T = 19.970000 C 06:01:29 Temperature Measurement, Probe Number = 3, T = 19.961000 C 06:01:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:01:29 Integrated Voltage Measurement... 06:01:49 Voltage Offset Correction: v_off_ini = 0.000001153 V, v_off_fin = 0.000005871 V 06:01:49 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438962 Vs 06:01:50 Integrated Voltage Measurement... 06:02:09 Voltage Offset Correction: v_off_ini = 0.000005454 V, v_off_fin = -0.000002716 V 06:02:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305821 Vs 06:02:12 Temperature Measurement, Probe Number = 0, T = 20.160000 C 06:02:12 Temperature Measurement, Probe Number = 1, T = 20.004000 C 06:02:13 Temperature Measurement, Probe Number = 2, T = 19.972000 C 06:02:14 Temperature Measurement, Probe Number = 3, T = 19.964000 C 06:02:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:02:14 Integrated Voltage Measurement... 06:02:34 Voltage Offset Correction: v_off_ini = 0.000001071 V, v_off_fin = 0.000006053 V 06:02:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434769 Vs 06:02:34 Integrated Voltage Measurement... 06:02:54 Voltage Offset Correction: v_off_ini = 0.000005425 V, v_off_fin = -0.000002039 V 06:02:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314917 Vs 06:02:56 Temperature Measurement, Probe Number = 0, T = 20.163000 C 06:02:57 Temperature Measurement, Probe Number = 1, T = 20.007000 C 06:02:58 Temperature Measurement, Probe Number = 2, T = 19.976000 C 06:02:58 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:02:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:02:59 Integrated Voltage Measurement... 06:03:18 Voltage Offset Correction: v_off_ini = 0.000001981 V, v_off_fin = 0.000005112 V 06:03:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431286 Vs 06:03:19 Integrated Voltage Measurement... 06:03:38 Voltage Offset Correction: v_off_ini = 0.000004471 V, v_off_fin = -0.000001645 V 06:03:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312566 Vs 06:03:41 Temperature Measurement, Probe Number = 0, T = 20.150000 C 06:03:41 Temperature Measurement, Probe Number = 1, T = 20.003000 C 06:03:42 Temperature Measurement, Probe Number = 2, T = 19.976000 C 06:03:43 Temperature Measurement, Probe Number = 3, T = 19.961000 C 06:03:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:03:43 Integrated Voltage Measurement... 06:04:03 Voltage Offset Correction: v_off_ini = 0.000001094 V, v_off_fin = 0.000005674 V 06:04:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430702 Vs 06:04:03 Integrated Voltage Measurement... 06:04:22 Voltage Offset Correction: v_off_ini = 0.000004749 V, v_off_fin = -0.000002428 V 06:04:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315640 Vs 06:04:25 Temperature Measurement, Probe Number = 0, T = 20.165000 C 06:04:25 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:04:26 Temperature Measurement, Probe Number = 2, T = 19.972000 C 06:04:27 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:04:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:04:27 Integrated Voltage Measurement... 06:04:46 Voltage Offset Correction: v_off_ini = 0.000001396 V, v_off_fin = 0.000005980 V 06:04:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435067 Vs 06:04:46 Integrated Voltage Measurement... 06:05:06 Voltage Offset Correction: v_off_ini = 0.000005059 V, v_off_fin = -0.000002383 V 06:05:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316216 Vs 06:05:09 Temperature Measurement, Probe Number = 0, T = 20.157000 C 06:05:09 Temperature Measurement, Probe Number = 1, T = 20.003000 C 06:05:10 Temperature Measurement, Probe Number = 2, T = 19.975000 C 06:05:11 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:05:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:05:11 Integrated Voltage Measurement... 06:05:30 Voltage Offset Correction: v_off_ini = 0.000001189 V, v_off_fin = 0.000005686 V 06:05:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434647 Vs 06:05:30 Integrated Voltage Measurement... 06:05:49 Voltage Offset Correction: v_off_ini = 0.000005081 V, v_off_fin = -0.000002777 V 06:05:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316913 Vs 06:05:52 Temperature Measurement, Probe Number = 0, T = 20.149000 C 06:05:53 Temperature Measurement, Probe Number = 1, T = 20.003000 C 06:05:53 Temperature Measurement, Probe Number = 2, T = 19.976000 C 06:05:54 Temperature Measurement, Probe Number = 3, T = 19.965000 C 06:05:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:05:54 Integrated Voltage Measurement... 06:06:13 Voltage Offset Correction: v_off_ini = 0.000000579 V, v_off_fin = 0.000005935 V 06:06:13 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175430683 Vs 06:06:14 Integrated Voltage Measurement... 06:06:33 Voltage Offset Correction: v_off_ini = 0.000004625 V, v_off_fin = -0.000002976 V 06:06:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323177 Vs 06:06:36 Temperature Measurement, Probe Number = 0, T = 20.208000 C 06:06:37 Temperature Measurement, Probe Number = 1, T = 20.002000 C 06:06:37 Temperature Measurement, Probe Number = 2, T = 19.975000 C 06:06:38 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:06:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:06:38 Integrated Voltage Measurement... 06:06:58 Voltage Offset Correction: v_off_ini = 0.000000828 V, v_off_fin = 0.000005686 V 06:06:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428837 Vs 06:06:58 Integrated Voltage Measurement... 06:07:17 Voltage Offset Correction: v_off_ini = 0.000004827 V, v_off_fin = -0.000002208 V 06:07:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316036 Vs 06:07:20 Temperature Measurement, Probe Number = 0, T = 20.201000 C 06:07:21 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:07:22 Temperature Measurement, Probe Number = 2, T = 19.976000 C 06:07:22 Temperature Measurement, Probe Number = 3, T = 19.964000 C 06:07:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:07:22 Integrated Voltage Measurement... 06:07:42 Voltage Offset Correction: v_off_ini = 0.000001411 V, v_off_fin = 0.000005705 V 06:07:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434700 Vs 06:07:43 Integrated Voltage Measurement... 06:08:02 Voltage Offset Correction: v_off_ini = 0.000004841 V, v_off_fin = -0.000002189 V 06:08:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322078 Vs 06:38:05 Temperature Measurement, Probe Number = 0, T = 20.157000 C 06:38:06 Temperature Measurement, Probe Number = 1, T = 19.999000 C 06:38:06 Temperature Measurement, Probe Number = 2, T = 19.971000 C 06:38:07 Temperature Measurement, Probe Number = 3, T = 19.961000 C 06:38:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:38:07 Integrated Voltage Measurement... 06:38:26 Voltage Offset Correction: v_off_ini = 0.000003452 V, v_off_fin = 0.000005628 V 06:38:26 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175521905 Vs 06:38:26 Integrated Voltage Measurement... 06:38:46 Voltage Offset Correction: v_off_ini = 0.000004625 V, v_off_fin = -0.000002827 V 06:38:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315511 Vs 06:38:49 Temperature Measurement, Probe Number = 0, T = 20.172000 C 06:38:49 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:38:50 Temperature Measurement, Probe Number = 2, T = 19.973000 C 06:38:51 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:38:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:38:51 Integrated Voltage Measurement... 06:39:10 Voltage Offset Correction: v_off_ini = 0.000000656 V, v_off_fin = 0.000004921 V 06:39:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418978 Vs 06:39:10 Integrated Voltage Measurement... 06:39:30 Voltage Offset Correction: v_off_ini = 0.000003731 V, v_off_fin = -0.000002538 V 06:39:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319753 Vs 06:39:33 Temperature Measurement, Probe Number = 0, T = 20.197000 C 06:39:33 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:39:34 Temperature Measurement, Probe Number = 2, T = 19.971000 C 06:39:35 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:39:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:39:35 Integrated Voltage Measurement... 06:39:54 Voltage Offset Correction: v_off_ini = 0.000001215 V, v_off_fin = 0.000005100 V 06:39:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419451 Vs 06:39:55 Integrated Voltage Measurement... 06:40:14 Voltage Offset Correction: v_off_ini = 0.000004557 V, v_off_fin = -0.000002230 V 06:40:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316104 Vs 06:40:17 Temperature Measurement, Probe Number = 0, T = 20.209000 C 06:40:18 Temperature Measurement, Probe Number = 1, T = 20.001000 C 06:40:18 Temperature Measurement, Probe Number = 2, T = 19.974000 C 06:40:19 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:40:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:40:19 Integrated Voltage Measurement... 06:40:38 Voltage Offset Correction: v_off_ini = 0.000001429 V, v_off_fin = 0.000005445 V 06:40:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424734 Vs 06:40:39 Integrated Voltage Measurement... 06:40:58 Voltage Offset Correction: v_off_ini = 0.000004665 V, v_off_fin = -0.000002449 V 06:40:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312072 Vs 06:41:01 Temperature Measurement, Probe Number = 0, T = 20.252000 C 06:41:02 Temperature Measurement, Probe Number = 1, T = 20.004000 C 06:41:02 Temperature Measurement, Probe Number = 2, T = 19.974000 C 06:41:03 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:41:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:41:03 Integrated Voltage Measurement... 06:41:23 Voltage Offset Correction: v_off_ini = 0.000001732 V, v_off_fin = 0.000005664 V 06:41:23 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423661 Vs 06:41:23 Integrated Voltage Measurement... 06:41:43 Voltage Offset Correction: v_off_ini = 0.000004778 V, v_off_fin = -0.000002605 V 06:41:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313202 Vs 06:41:45 Temperature Measurement, Probe Number = 0, T = 20.241000 C 06:41:46 Temperature Measurement, Probe Number = 1, T = 20.001000 C 06:41:47 Temperature Measurement, Probe Number = 2, T = 19.973000 C 06:41:47 Temperature Measurement, Probe Number = 3, T = 19.959000 C 06:41:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:41:47 Integrated Voltage Measurement... 06:42:06 Voltage Offset Correction: v_off_ini = 0.000001256 V, v_off_fin = 0.000005397 V 06:42:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422324 Vs 06:42:07 Integrated Voltage Measurement... 06:42:26 Voltage Offset Correction: v_off_ini = 0.000004403 V, v_off_fin = -0.000002448 V 06:42:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320449 Vs 06:42:29 Temperature Measurement, Probe Number = 0, T = 20.225000 C 06:42:30 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:42:30 Temperature Measurement, Probe Number = 2, T = 19.971000 C 06:42:31 Temperature Measurement, Probe Number = 3, T = 19.957000 C 06:42:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:42:31 Integrated Voltage Measurement... 06:42:50 Voltage Offset Correction: v_off_ini = 0.000001437 V, v_off_fin = 0.000005477 V 06:42:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424542 Vs 06:42:51 Integrated Voltage Measurement... 06:43:10 Voltage Offset Correction: v_off_ini = 0.000004662 V, v_off_fin = -0.000002811 V 06:43:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311945 Vs 06:43:13 Temperature Measurement, Probe Number = 0, T = 20.201000 C 06:43:13 Temperature Measurement, Probe Number = 1, T = 20.000000 C 06:43:14 Temperature Measurement, Probe Number = 2, T = 19.972000 C 06:43:15 Temperature Measurement, Probe Number = 3, T = 19.958000 C 06:43:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:43:15 Integrated Voltage Measurement... 06:43:34 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = 0.000005177 V 06:43:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427326 Vs 06:43:35 Integrated Voltage Measurement... 06:43:54 Voltage Offset Correction: v_off_ini = 0.000004563 V, v_off_fin = -0.000001139 V 06:43:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323949 Vs 06:43:57 Temperature Measurement, Probe Number = 0, T = 20.249000 C 06:43:58 Temperature Measurement, Probe Number = 1, T = 20.002000 C 06:43:59 Temperature Measurement, Probe Number = 2, T = 19.971000 C 06:43:59 Temperature Measurement, Probe Number = 3, T = 19.963000 C 06:43:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 06:43:59 Integrated Voltage Measurement... 06:44:18 Voltage Offset Correction: v_off_ini = 0.000001113 V, v_off_fin = 0.000006150 V 06:44:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422096 Vs 06:44:19 Integrated Voltage Measurement... 06:44:38 Voltage Offset Correction: v_off_ini = 0.000005065 V, v_off_fin = -0.000002080 V 06:44:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310423 Vs 06:44:41 Temperature Measurement, Probe Number = 0, T = 20.319000 C 06:44:41 Temperature Measurement, Probe Number = 1, T = 20.006000 C 06:44:42 Temperature Measurement, Probe Number = 2, T = 19.975000 C 06:44:43 Temperature Measurement, Probe Number = 3, T = 19.962000 C 06:44:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 06:44:43 Integrated Voltage Measurement... 06:45:02 Voltage Offset Correction: v_off_ini = 0.000001533 V, v_off_fin = 0.000006094 V 06:45:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426820 Vs 06:45:02 Integrated Voltage Measurement... 06:45:21 Voltage Offset Correction: v_off_ini = 0.000005022 V, v_off_fin = -0.000002434 V 06:45:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305689 Vs 07:15:24 Temperature Measurement, Probe Number = 0, T = 20.288000 C 07:15:25 Temperature Measurement, Probe Number = 1, T = 20.002000 C 07:15:26 Temperature Measurement, Probe Number = 2, T = 19.973000 C 07:15:26 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:15:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:15:27 Integrated Voltage Measurement... 07:15:46 Voltage Offset Correction: v_off_ini = 0.000003438 V, v_off_fin = 0.000006058 V 07:15:46 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175522922 Vs 07:15:46 Integrated Voltage Measurement... 07:16:05 Voltage Offset Correction: v_off_ini = 0.000004711 V, v_off_fin = -0.000002041 V 07:16:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308870 Vs 07:16:08 Temperature Measurement, Probe Number = 0, T = 20.289000 C 07:16:09 Temperature Measurement, Probe Number = 1, T = 20.002000 C 07:16:10 Temperature Measurement, Probe Number = 2, T = 19.972000 C 07:16:10 Temperature Measurement, Probe Number = 3, T = 19.961000 C 07:16:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:16:11 Integrated Voltage Measurement... 07:16:30 Voltage Offset Correction: v_off_ini = 0.000001269 V, v_off_fin = 0.000005719 V 07:16:30 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413487 Vs 07:16:30 Integrated Voltage Measurement... 07:16:49 Voltage Offset Correction: v_off_ini = 0.000005223 V, v_off_fin = -0.000001606 V 07:16:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309042 Vs 07:16:52 Temperature Measurement, Probe Number = 0, T = 20.251000 C 07:16:53 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:16:54 Temperature Measurement, Probe Number = 2, T = 19.975000 C 07:16:54 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:16:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:16:54 Integrated Voltage Measurement... 07:17:14 Voltage Offset Correction: v_off_ini = 0.000001791 V, v_off_fin = 0.000005918 V 07:17:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175420059 Vs 07:17:14 Integrated Voltage Measurement... 07:17:33 Voltage Offset Correction: v_off_ini = 0.000004395 V, v_off_fin = -0.000002254 V 07:17:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321580 Vs 07:17:36 Temperature Measurement, Probe Number = 0, T = 20.250000 C 07:17:37 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:17:38 Temperature Measurement, Probe Number = 2, T = 19.975000 C 07:17:38 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:17:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:17:38 Integrated Voltage Measurement... 07:17:58 Voltage Offset Correction: v_off_ini = 0.000000910 V, v_off_fin = 0.000005358 V 07:17:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419994 Vs 07:17:58 Integrated Voltage Measurement... 07:18:17 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = -0.000002801 V 07:18:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317589 Vs 07:18:20 Temperature Measurement, Probe Number = 0, T = 20.262000 C 07:18:21 Temperature Measurement, Probe Number = 1, T = 20.004000 C 07:18:22 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:18:22 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:18:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 07:18:22 Integrated Voltage Measurement... 07:18:42 Voltage Offset Correction: v_off_ini = 0.000000805 V, v_off_fin = 0.000005356 V 07:18:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420971 Vs 07:18:42 Integrated Voltage Measurement... 07:19:01 Voltage Offset Correction: v_off_ini = 0.000004678 V, v_off_fin = -0.000002742 V 07:19:01 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175313520 Vs 07:19:04 Temperature Measurement, Probe Number = 0, T = 20.302000 C 07:19:05 Temperature Measurement, Probe Number = 1, T = 20.007000 C 07:19:05 Temperature Measurement, Probe Number = 2, T = 19.979000 C 07:19:06 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:19:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 07:19:06 Integrated Voltage Measurement... 07:19:25 Voltage Offset Correction: v_off_ini = 0.000001615 V, v_off_fin = 0.000005900 V 07:19:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429957 Vs 07:19:26 Integrated Voltage Measurement... 07:19:45 Voltage Offset Correction: v_off_ini = 0.000005383 V, v_off_fin = -0.000001591 V 07:19:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306810 Vs 07:19:48 Temperature Measurement, Probe Number = 0, T = 20.294000 C 07:19:49 Temperature Measurement, Probe Number = 1, T = 20.006000 C 07:19:49 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:19:50 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:19:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:19:50 Integrated Voltage Measurement... 07:20:09 Voltage Offset Correction: v_off_ini = 0.000001161 V, v_off_fin = 0.000006222 V 07:20:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425789 Vs 07:20:10 Integrated Voltage Measurement... 07:20:29 Voltage Offset Correction: v_off_ini = 0.000004928 V, v_off_fin = -0.000003161 V 07:20:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314525 Vs 07:20:32 Temperature Measurement, Probe Number = 0, T = 20.258000 C 07:20:32 Temperature Measurement, Probe Number = 1, T = 20.006000 C 07:20:33 Temperature Measurement, Probe Number = 2, T = 19.976000 C 07:20:34 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:20:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:20:34 Integrated Voltage Measurement... 07:20:53 Voltage Offset Correction: v_off_ini = 0.000000409 V, v_off_fin = 0.000005348 V 07:20:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423043 Vs 07:20:53 Integrated Voltage Measurement... 07:21:12 Voltage Offset Correction: v_off_ini = 0.000004650 V, v_off_fin = -0.000002630 V 07:21:12 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175319873 Vs 07:21:15 Temperature Measurement, Probe Number = 0, T = 20.233000 C 07:21:16 Temperature Measurement, Probe Number = 1, T = 20.005000 C 07:21:16 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:21:17 Temperature Measurement, Probe Number = 3, T = 19.965000 C 07:21:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:21:17 Integrated Voltage Measurement... 07:21:36 Voltage Offset Correction: v_off_ini = 0.000000974 V, v_off_fin = 0.000005160 V 07:21:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426855 Vs 07:21:36 Integrated Voltage Measurement... 07:21:55 Voltage Offset Correction: v_off_ini = 0.000004941 V, v_off_fin = -0.000002828 V 07:21:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312099 Vs 07:21:58 Temperature Measurement, Probe Number = 0, T = 20.259000 C 07:21:59 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:21:59 Temperature Measurement, Probe Number = 2, T = 19.974000 C 07:22:00 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:22:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:22:00 Integrated Voltage Measurement... 07:22:19 Voltage Offset Correction: v_off_ini = 0.000000926 V, v_off_fin = 0.000005966 V 07:22:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429201 Vs 07:22:19 Integrated Voltage Measurement... 07:22:39 Voltage Offset Correction: v_off_ini = 0.000004951 V, v_off_fin = -0.000003005 V 07:22:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317904 Vs 07:52:42 Temperature Measurement, Probe Number = 0, T = 20.237000 C 07:52:43 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:52:43 Temperature Measurement, Probe Number = 2, T = 19.972000 C 07:52:44 Temperature Measurement, Probe Number = 3, T = 19.961000 C 07:52:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:52:44 Integrated Voltage Measurement... 07:53:03 Voltage Offset Correction: v_off_ini = 0.000003033 V, v_off_fin = 0.000005613 V 07:53:03 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175520965 Vs 07:53:04 Integrated Voltage Measurement... 07:53:23 Voltage Offset Correction: v_off_ini = 0.000004805 V, v_off_fin = -0.000001912 V 07:53:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303366 Vs 07:53:26 Temperature Measurement, Probe Number = 0, T = 20.218000 C 07:53:26 Temperature Measurement, Probe Number = 1, T = 20.004000 C 07:53:27 Temperature Measurement, Probe Number = 2, T = 19.975000 C 07:53:28 Temperature Measurement, Probe Number = 3, T = 19.962000 C 07:53:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:53:28 Integrated Voltage Measurement... 07:53:47 Voltage Offset Correction: v_off_ini = 0.000000700 V, v_off_fin = 0.000005532 V 07:53:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415781 Vs 07:53:47 Integrated Voltage Measurement... 07:54:07 Voltage Offset Correction: v_off_ini = 0.000004980 V, v_off_fin = -0.000002601 V 07:54:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313147 Vs 07:54:10 Temperature Measurement, Probe Number = 0, T = 20.222000 C 07:54:10 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:54:11 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:54:12 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:54:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:54:12 Integrated Voltage Measurement... 07:54:31 Voltage Offset Correction: v_off_ini = 0.000000769 V, v_off_fin = 0.000005024 V 07:54:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420320 Vs 07:54:31 Integrated Voltage Measurement... 07:54:51 Voltage Offset Correction: v_off_ini = 0.000004284 V, v_off_fin = -0.000002237 V 07:54:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318506 Vs 07:54:54 Temperature Measurement, Probe Number = 0, T = 20.251000 C 07:54:54 Temperature Measurement, Probe Number = 1, T = 20.005000 C 07:54:55 Temperature Measurement, Probe Number = 2, T = 19.980000 C 07:54:56 Temperature Measurement, Probe Number = 3, T = 19.966000 C 07:54:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 07:54:56 Integrated Voltage Measurement... 07:55:15 Voltage Offset Correction: v_off_ini = 0.000000754 V, v_off_fin = 0.000004861 V 07:55:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175415465 Vs 07:55:16 Integrated Voltage Measurement... 07:55:35 Voltage Offset Correction: v_off_ini = 0.000003883 V, v_off_fin = -0.000003597 V 07:55:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314065 Vs 07:55:38 Temperature Measurement, Probe Number = 0, T = 20.332000 C 07:55:39 Temperature Measurement, Probe Number = 1, T = 20.005000 C 07:55:39 Temperature Measurement, Probe Number = 2, T = 19.978000 C 07:55:40 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:55:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:55:40 Integrated Voltage Measurement... 07:55:59 Voltage Offset Correction: v_off_ini = 0.000000783 V, v_off_fin = 0.000005377 V 07:55:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416068 Vs 07:55:59 Integrated Voltage Measurement... 07:56:18 Voltage Offset Correction: v_off_ini = 0.000004472 V, v_off_fin = -0.000003365 V 07:56:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311934 Vs 07:56:21 Temperature Measurement, Probe Number = 0, T = 20.295000 C 07:56:22 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:56:23 Temperature Measurement, Probe Number = 2, T = 19.973000 C 07:56:23 Temperature Measurement, Probe Number = 3, T = 19.961000 C 07:56:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:56:23 Integrated Voltage Measurement... 07:56:42 Voltage Offset Correction: v_off_ini = 0.000000422 V, v_off_fin = 0.000005660 V 07:56:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428843 Vs 07:56:43 Integrated Voltage Measurement... 07:57:02 Voltage Offset Correction: v_off_ini = 0.000004975 V, v_off_fin = -0.000002573 V 07:57:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309859 Vs 07:57:05 Temperature Measurement, Probe Number = 0, T = 20.227000 C 07:57:06 Temperature Measurement, Probe Number = 1, T = 20.003000 C 07:57:06 Temperature Measurement, Probe Number = 2, T = 19.974000 C 07:57:07 Temperature Measurement, Probe Number = 3, T = 19.963000 C 07:57:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 07:57:07 Integrated Voltage Measurement... 07:57:26 Voltage Offset Correction: v_off_ini = 0.000001033 V, v_off_fin = 0.000005417 V 07:57:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422791 Vs 07:57:27 Integrated Voltage Measurement... 07:57:46 Voltage Offset Correction: v_off_ini = 0.000005312 V, v_off_fin = -0.000002452 V 07:57:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310719 Vs 07:57:49 Temperature Measurement, Probe Number = 0, T = 20.254000 C 07:57:50 Temperature Measurement, Probe Number = 1, T = 20.007000 C 07:57:50 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:57:51 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:57:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 07:57:51 Integrated Voltage Measurement... 07:58:10 Voltage Offset Correction: v_off_ini = 0.000000467 V, v_off_fin = 0.000005482 V 07:58:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422266 Vs 07:58:11 Integrated Voltage Measurement... 07:58:30 Voltage Offset Correction: v_off_ini = 0.000004968 V, v_off_fin = -0.000002673 V 07:58:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317595 Vs 07:58:33 Temperature Measurement, Probe Number = 0, T = 20.344000 C 07:58:34 Temperature Measurement, Probe Number = 1, T = 20.009000 C 07:58:34 Temperature Measurement, Probe Number = 2, T = 19.980000 C 07:58:35 Temperature Measurement, Probe Number = 3, T = 19.967000 C 07:58:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 07:58:35 Integrated Voltage Measurement... 07:58:54 Voltage Offset Correction: v_off_ini = 0.000000998 V, v_off_fin = 0.000005388 V 07:58:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423383 Vs 07:58:55 Integrated Voltage Measurement... 07:59:14 Voltage Offset Correction: v_off_ini = 0.000004895 V, v_off_fin = -0.000002799 V 07:59:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306434 Vs 07:59:17 Temperature Measurement, Probe Number = 0, T = 20.323000 C 07:59:17 Temperature Measurement, Probe Number = 1, T = 20.007000 C 07:59:18 Temperature Measurement, Probe Number = 2, T = 19.977000 C 07:59:19 Temperature Measurement, Probe Number = 3, T = 19.964000 C 07:59:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 07:59:19 Integrated Voltage Measurement... 07:59:38 Voltage Offset Correction: v_off_ini = 0.000000636 V, v_off_fin = 0.000005056 V 07:59:39 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426467 Vs 07:59:39 Integrated Voltage Measurement... 07:59:58 Voltage Offset Correction: v_off_ini = 0.000004893 V, v_off_fin = -0.000002558 V 07:59:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309734 Vs 08:30:01 Temperature Measurement, Probe Number = 0, T = 20.308000 C 08:30:02 Temperature Measurement, Probe Number = 1, T = 20.006000 C 08:30:02 Temperature Measurement, Probe Number = 2, T = 19.980000 C 08:30:03 Temperature Measurement, Probe Number = 3, T = 19.961000 C 08:30:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 08:30:03 Integrated Voltage Measurement... 08:30:22 Voltage Offset Correction: v_off_ini = 0.000003377 V, v_off_fin = 0.000006036 V 08:30:22 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175519527 Vs 08:30:22 Integrated Voltage Measurement... 08:30:41 Voltage Offset Correction: v_off_ini = 0.000005087 V, v_off_fin = -0.000003263 V 08:30:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307861 Vs 08:30:44 Temperature Measurement, Probe Number = 0, T = 20.330000 C 08:30:45 Temperature Measurement, Probe Number = 1, T = 20.006000 C 08:30:46 Temperature Measurement, Probe Number = 2, T = 19.979000 C 08:30:46 Temperature Measurement, Probe Number = 3, T = 19.962000 C 08:30:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 08:30:46 Integrated Voltage Measurement... 08:31:05 Voltage Offset Correction: v_off_ini = 0.000001013 V, v_off_fin = 0.000005255 V 08:31:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421361 Vs 08:31:06 Integrated Voltage Measurement... 08:31:25 Voltage Offset Correction: v_off_ini = 0.000004287 V, v_off_fin = -0.000002343 V 08:31:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313994 Vs 08:31:28 Temperature Measurement, Probe Number = 0, T = 20.255000 C 08:31:29 Temperature Measurement, Probe Number = 1, T = 20.007000 C 08:31:29 Temperature Measurement, Probe Number = 2, T = 19.980000 C 08:31:30 Temperature Measurement, Probe Number = 3, T = 19.962000 C 08:31:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 08:31:30 Integrated Voltage Measurement... 08:31:50 Voltage Offset Correction: v_off_ini = 0.000001170 V, v_off_fin = 0.000005243 V 08:31:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420359 Vs 08:31:50 Integrated Voltage Measurement... 08:32:09 Voltage Offset Correction: v_off_ini = 0.000004537 V, v_off_fin = -0.000003023 V 08:32:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315566 Vs 08:32:12 Temperature Measurement, Probe Number = 0, T = 20.291000 C 08:32:13 Temperature Measurement, Probe Number = 1, T = 20.009000 C 08:32:14 Temperature Measurement, Probe Number = 2, T = 19.982000 C 08:32:14 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:32:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:32:14 Integrated Voltage Measurement... 08:32:34 Voltage Offset Correction: v_off_ini = 0.000000374 V, v_off_fin = 0.000005275 V 08:32:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420570 Vs 08:32:34 Integrated Voltage Measurement... 08:32:53 Voltage Offset Correction: v_off_ini = 0.000004391 V, v_off_fin = -0.000003109 V 08:32:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316774 Vs 08:32:56 Temperature Measurement, Probe Number = 0, T = 20.322000 C 08:32:57 Temperature Measurement, Probe Number = 1, T = 20.010000 C 08:32:58 Temperature Measurement, Probe Number = 2, T = 19.982000 C 08:32:58 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:32:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:32:58 Integrated Voltage Measurement... 08:33:18 Voltage Offset Correction: v_off_ini = 0.000000712 V, v_off_fin = 0.000005717 V 08:33:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424570 Vs 08:33:18 Integrated Voltage Measurement... 08:33:37 Voltage Offset Correction: v_off_ini = 0.000005334 V, v_off_fin = -0.000003352 V 08:33:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309653 Vs 08:33:40 Temperature Measurement, Probe Number = 0, T = 20.383000 C 08:33:40 Temperature Measurement, Probe Number = 1, T = 20.012000 C 08:33:41 Temperature Measurement, Probe Number = 2, T = 19.984000 C 08:33:42 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:33:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:33:42 Integrated Voltage Measurement... 08:34:01 Voltage Offset Correction: v_off_ini = 0.000000322 V, v_off_fin = 0.000005452 V 08:34:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423614 Vs 08:34:01 Integrated Voltage Measurement... 08:34:20 Voltage Offset Correction: v_off_ini = 0.000004626 V, v_off_fin = -0.000002150 V 08:34:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317858 Vs 08:34:23 Temperature Measurement, Probe Number = 0, T = 20.399000 C 08:34:24 Temperature Measurement, Probe Number = 1, T = 20.013000 C 08:34:25 Temperature Measurement, Probe Number = 2, T = 19.984000 C 08:34:25 Temperature Measurement, Probe Number = 3, T = 19.967000 C 08:34:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:34:25 Integrated Voltage Measurement... 08:34:45 Voltage Offset Correction: v_off_ini = 0.000001581 V, v_off_fin = 0.000005597 V 08:34:45 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429791 Vs 08:34:45 Integrated Voltage Measurement... 08:35:05 Voltage Offset Correction: v_off_ini = 0.000004928 V, v_off_fin = -0.000002878 V 08:35:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320127 Vs 08:35:07 Temperature Measurement, Probe Number = 0, T = 20.399000 C 08:35:08 Temperature Measurement, Probe Number = 1, T = 20.014000 C 08:35:09 Temperature Measurement, Probe Number = 2, T = 19.983000 C 08:35:09 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:35:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:35:10 Integrated Voltage Measurement... 08:35:29 Voltage Offset Correction: v_off_ini = 0.000001303 V, v_off_fin = 0.000005437 V 08:35:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423324 Vs 08:35:29 Integrated Voltage Measurement... 08:35:49 Voltage Offset Correction: v_off_ini = 0.000004717 V, v_off_fin = -0.000001521 V 08:35:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314866 Vs 08:35:51 Temperature Measurement, Probe Number = 0, T = 20.392000 C 08:35:52 Temperature Measurement, Probe Number = 1, T = 20.011000 C 08:35:53 Temperature Measurement, Probe Number = 2, T = 19.981000 C 08:35:53 Temperature Measurement, Probe Number = 3, T = 19.965000 C 08:35:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 08:35:54 Integrated Voltage Measurement... 08:36:13 Voltage Offset Correction: v_off_ini = 0.000001501 V, v_off_fin = 0.000005499 V 08:36:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426659 Vs 08:36:13 Integrated Voltage Measurement... 08:36:33 Voltage Offset Correction: v_off_ini = 0.000004647 V, v_off_fin = -0.000003167 V 08:36:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314701 Vs 08:36:36 Temperature Measurement, Probe Number = 0, T = 20.419000 C 08:36:36 Temperature Measurement, Probe Number = 1, T = 20.007000 C 08:36:37 Temperature Measurement, Probe Number = 2, T = 19.980000 C 08:36:38 Temperature Measurement, Probe Number = 3, T = 19.966000 C 08:36:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 08:36:38 Integrated Voltage Measurement... 08:36:57 Voltage Offset Correction: v_off_ini = 0.000001193 V, v_off_fin = 0.000005406 V 08:36:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427660 Vs 08:36:57 Integrated Voltage Measurement... 08:37:16 Voltage Offset Correction: v_off_ini = 0.000004843 V, v_off_fin = -0.000002944 V 08:37:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313932 Vs 09:07:19 Temperature Measurement, Probe Number = 0, T = 20.211000 C 09:07:20 Temperature Measurement, Probe Number = 1, T = 20.007000 C 09:07:20 Temperature Measurement, Probe Number = 2, T = 19.978000 C 09:07:21 Temperature Measurement, Probe Number = 3, T = 19.963000 C 09:07:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:07:21 Integrated Voltage Measurement... 09:07:41 Voltage Offset Correction: v_off_ini = 0.000004296 V, v_off_fin = 0.000005731 V 09:07:41 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175528643 Vs 09:07:41 Integrated Voltage Measurement... 09:08:01 Voltage Offset Correction: v_off_ini = 0.000004852 V, v_off_fin = -0.000002699 V 09:08:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311702 Vs 09:08:03 Temperature Measurement, Probe Number = 0, T = 20.237000 C 09:08:04 Temperature Measurement, Probe Number = 1, T = 20.008000 C 09:08:05 Temperature Measurement, Probe Number = 2, T = 19.978000 C 09:08:05 Temperature Measurement, Probe Number = 3, T = 19.963000 C 09:08:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:08:06 Integrated Voltage Measurement... 09:08:25 Voltage Offset Correction: v_off_ini = 0.000001335 V, v_off_fin = 0.000005482 V 09:08:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427368 Vs 09:08:25 Integrated Voltage Measurement... 09:08:44 Voltage Offset Correction: v_off_ini = 0.000005077 V, v_off_fin = -0.000002581 V 09:08:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315904 Vs 09:08:47 Temperature Measurement, Probe Number = 0, T = 20.293000 C 09:08:48 Temperature Measurement, Probe Number = 1, T = 20.007000 C 09:08:49 Temperature Measurement, Probe Number = 2, T = 19.977000 C 09:08:49 Temperature Measurement, Probe Number = 3, T = 19.963000 C 09:08:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:08:49 Integrated Voltage Measurement... 09:09:09 Voltage Offset Correction: v_off_ini = 0.000000164 V, v_off_fin = 0.000005719 V 09:09:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427949 Vs 09:09:09 Integrated Voltage Measurement... 09:09:28 Voltage Offset Correction: v_off_ini = 0.000005076 V, v_off_fin = -0.000002777 V 09:09:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305887 Vs 09:09:31 Temperature Measurement, Probe Number = 0, T = 20.284000 C 09:09:32 Temperature Measurement, Probe Number = 1, T = 20.007000 C 09:09:32 Temperature Measurement, Probe Number = 2, T = 19.979000 C 09:09:33 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:09:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:09:33 Integrated Voltage Measurement... 09:09:52 Voltage Offset Correction: v_off_ini = 0.000000685 V, v_off_fin = 0.000005956 V 09:09:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426708 Vs 09:09:52 Integrated Voltage Measurement... 09:10:12 Voltage Offset Correction: v_off_ini = 0.000004723 V, v_off_fin = -0.000002765 V 09:10:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311220 Vs 09:10:15 Temperature Measurement, Probe Number = 0, T = 20.259000 C 09:10:15 Temperature Measurement, Probe Number = 1, T = 20.005000 C 09:10:16 Temperature Measurement, Probe Number = 2, T = 19.976000 C 09:10:16 Temperature Measurement, Probe Number = 3, T = 19.960000 C 09:10:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:10:17 Integrated Voltage Measurement... 09:10:36 Voltage Offset Correction: v_off_ini = 0.000001343 V, v_off_fin = 0.000005902 V 09:10:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428368 Vs 09:10:36 Integrated Voltage Measurement... 09:10:55 Voltage Offset Correction: v_off_ini = 0.000004979 V, v_off_fin = -0.000002148 V 09:10:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307159 Vs 09:10:58 Temperature Measurement, Probe Number = 0, T = 20.202000 C 09:10:59 Temperature Measurement, Probe Number = 1, T = 20.006000 C 09:10:59 Temperature Measurement, Probe Number = 2, T = 19.976000 C 09:11:00 Temperature Measurement, Probe Number = 3, T = 19.960000 C 09:11:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:11:00 Integrated Voltage Measurement... 09:11:19 Voltage Offset Correction: v_off_ini = 0.000001571 V, v_off_fin = 0.000006091 V 09:11:20 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175436149 Vs 09:11:20 Integrated Voltage Measurement... 09:11:39 Voltage Offset Correction: v_off_ini = 0.000004925 V, v_off_fin = -0.000002105 V 09:11:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310407 Vs 09:11:42 Temperature Measurement, Probe Number = 0, T = 20.218000 C 09:11:42 Temperature Measurement, Probe Number = 1, T = 20.007000 C 09:11:43 Temperature Measurement, Probe Number = 2, T = 19.977000 C 09:11:44 Temperature Measurement, Probe Number = 3, T = 19.962000 C 09:11:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:11:44 Integrated Voltage Measurement... 09:12:03 Voltage Offset Correction: v_off_ini = 0.000000639 V, v_off_fin = 0.000005888 V 09:12:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428190 Vs 09:12:03 Integrated Voltage Measurement... 09:12:22 Voltage Offset Correction: v_off_ini = 0.000005134 V, v_off_fin = -0.000001872 V 09:12:22 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175306545 Vs 09:12:25 Temperature Measurement, Probe Number = 0, T = 20.285000 C 09:12:26 Temperature Measurement, Probe Number = 1, T = 20.010000 C 09:12:26 Temperature Measurement, Probe Number = 2, T = 19.981000 C 09:12:27 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:12:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:12:27 Integrated Voltage Measurement... 09:12:46 Voltage Offset Correction: v_off_ini = 0.000001073 V, v_off_fin = 0.000005970 V 09:12:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432452 Vs 09:12:47 Integrated Voltage Measurement... 09:13:06 Voltage Offset Correction: v_off_ini = 0.000005618 V, v_off_fin = -0.000002589 V 09:13:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312180 Vs 09:13:09 Temperature Measurement, Probe Number = 0, T = 20.340000 C 09:13:10 Temperature Measurement, Probe Number = 1, T = 20.011000 C 09:13:10 Temperature Measurement, Probe Number = 2, T = 19.982000 C 09:13:11 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:13:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:13:11 Integrated Voltage Measurement... 09:13:30 Voltage Offset Correction: v_off_ini = 0.000001303 V, v_off_fin = 0.000006244 V 09:13:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429020 Vs 09:13:31 Integrated Voltage Measurement... 09:13:49 Voltage Offset Correction: v_off_ini = 0.000005684 V, v_off_fin = -0.000002616 V 09:13:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306621 Vs 09:13:52 Temperature Measurement, Probe Number = 0, T = 20.327000 C 09:13:53 Temperature Measurement, Probe Number = 1, T = 20.012000 C 09:13:54 Temperature Measurement, Probe Number = 2, T = 19.980000 C 09:13:54 Temperature Measurement, Probe Number = 3, T = 19.965000 C 09:13:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:13:55 Integrated Voltage Measurement... 09:14:14 Voltage Offset Correction: v_off_ini = 0.000000785 V, v_off_fin = 0.000005070 V 09:14:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425146 Vs 09:14:14 Integrated Voltage Measurement... 09:14:33 Voltage Offset Correction: v_off_ini = 0.000004340 V, v_off_fin = -0.000002295 V 09:14:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316510 Vs 09:44:36 Temperature Measurement, Probe Number = 0, T = 20.382000 C 09:44:37 Temperature Measurement, Probe Number = 1, T = 20.008000 C 09:44:37 Temperature Measurement, Probe Number = 2, T = 19.982000 C 09:44:38 Temperature Measurement, Probe Number = 3, T = 19.962000 C 09:44:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:44:38 Integrated Voltage Measurement... 09:44:57 Voltage Offset Correction: v_off_ini = 0.000003277 V, v_off_fin = 0.000005558 V 09:44:58 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175520145 Vs 09:44:58 Integrated Voltage Measurement... 09:45:17 Voltage Offset Correction: v_off_ini = 0.000005176 V, v_off_fin = -0.000001629 V 09:45:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304502 Vs 09:45:20 Temperature Measurement, Probe Number = 0, T = 20.295000 C 09:45:21 Temperature Measurement, Probe Number = 1, T = 20.010000 C 09:45:21 Temperature Measurement, Probe Number = 2, T = 19.983000 C 09:45:22 Temperature Measurement, Probe Number = 3, T = 19.965000 C 09:45:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:45:22 Integrated Voltage Measurement... 09:45:41 Voltage Offset Correction: v_off_ini = 0.000000823 V, v_off_fin = 0.000006015 V 09:45:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425774 Vs 09:45:42 Integrated Voltage Measurement... 09:46:01 Voltage Offset Correction: v_off_ini = 0.000005661 V, v_off_fin = -0.000002851 V 09:46:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317330 Vs 09:46:04 Temperature Measurement, Probe Number = 0, T = 20.234000 C 09:46:05 Temperature Measurement, Probe Number = 1, T = 20.011000 C 09:46:05 Temperature Measurement, Probe Number = 2, T = 19.984000 C 09:46:06 Temperature Measurement, Probe Number = 3, T = 19.967000 C 09:46:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:46:06 Integrated Voltage Measurement... 09:46:25 Voltage Offset Correction: v_off_ini = 0.000000971 V, v_off_fin = 0.000006258 V 09:46:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425829 Vs 09:46:25 Integrated Voltage Measurement... 09:46:45 Voltage Offset Correction: v_off_ini = 0.000005326 V, v_off_fin = -0.000001909 V 09:46:45 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175308756 Vs 09:46:47 Temperature Measurement, Probe Number = 0, T = 20.221000 C 09:46:48 Temperature Measurement, Probe Number = 1, T = 20.013000 C 09:46:49 Temperature Measurement, Probe Number = 2, T = 19.983000 C 09:46:49 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:46:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:46:50 Integrated Voltage Measurement... 09:47:09 Voltage Offset Correction: v_off_ini = 0.000001550 V, v_off_fin = 0.000006061 V 09:47:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426611 Vs 09:47:09 Integrated Voltage Measurement... 09:47:28 Voltage Offset Correction: v_off_ini = 0.000005055 V, v_off_fin = -0.000001271 V 09:47:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305034 Vs 09:47:31 Temperature Measurement, Probe Number = 0, T = 20.212000 C 09:47:32 Temperature Measurement, Probe Number = 1, T = 20.012000 C 09:47:33 Temperature Measurement, Probe Number = 2, T = 19.983000 C 09:47:33 Temperature Measurement, Probe Number = 3, T = 19.964000 C 09:47:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 09:47:33 Integrated Voltage Measurement... 09:47:52 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000006331 V 09:47:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426696 Vs 09:47:53 Integrated Voltage Measurement... 09:48:12 Voltage Offset Correction: v_off_ini = 0.000005423 V, v_off_fin = -0.000002547 V 09:48:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307763 Vs 09:48:15 Temperature Measurement, Probe Number = 0, T = 20.199000 C 09:48:16 Temperature Measurement, Probe Number = 1, T = 20.011000 C 09:48:16 Temperature Measurement, Probe Number = 2, T = 19.982000 C 09:48:17 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:48:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 09:48:17 Integrated Voltage Measurement... 09:48:37 Voltage Offset Correction: v_off_ini = 0.000001496 V, v_off_fin = 0.000005739 V 09:48:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425982 Vs 09:48:37 Integrated Voltage Measurement... 09:48:56 Voltage Offset Correction: v_off_ini = 0.000005006 V, v_off_fin = -0.000001682 V 09:48:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316099 Vs 09:48:59 Temperature Measurement, Probe Number = 0, T = 20.293000 C 09:49:00 Temperature Measurement, Probe Number = 1, T = 20.012000 C 09:49:01 Temperature Measurement, Probe Number = 2, T = 19.986000 C 09:49:01 Temperature Measurement, Probe Number = 3, T = 19.966000 C 09:49:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 09:49:01 Integrated Voltage Measurement... 09:49:21 Voltage Offset Correction: v_off_ini = 0.000000851 V, v_off_fin = 0.000005376 V 09:49:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420605 Vs 09:49:21 Integrated Voltage Measurement... 09:49:40 Voltage Offset Correction: v_off_ini = 0.000004751 V, v_off_fin = -0.000002457 V 09:49:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317956 Vs 09:49:43 Temperature Measurement, Probe Number = 0, T = 20.345000 C 09:49:44 Temperature Measurement, Probe Number = 1, T = 20.014000 C 09:49:45 Temperature Measurement, Probe Number = 2, T = 19.987000 C 09:49:45 Temperature Measurement, Probe Number = 3, T = 19.968000 C 09:49:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 09:49:45 Integrated Voltage Measurement... 09:50:05 Voltage Offset Correction: v_off_ini = 0.000001210 V, v_off_fin = 0.000005585 V 09:50:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433532 Vs 09:50:06 Integrated Voltage Measurement... 09:50:25 Voltage Offset Correction: v_off_ini = 0.000004912 V, v_off_fin = -0.000001962 V 09:50:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305440 Vs 09:50:28 Temperature Measurement, Probe Number = 0, T = 20.393000 C 09:50:29 Temperature Measurement, Probe Number = 1, T = 20.015000 C 09:50:29 Temperature Measurement, Probe Number = 2, T = 19.988000 C 09:50:30 Temperature Measurement, Probe Number = 3, T = 19.970000 C 09:50:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 09:50:30 Integrated Voltage Measurement... 09:50:50 Voltage Offset Correction: v_off_ini = 0.000001452 V, v_off_fin = 0.000005252 V 09:50:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427203 Vs 09:50:50 Integrated Voltage Measurement... 09:51:10 Voltage Offset Correction: v_off_ini = 0.000004748 V, v_off_fin = -0.000003035 V 09:51:10 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309466 Vs 09:51:12 Temperature Measurement, Probe Number = 0, T = 20.382000 C 09:51:13 Temperature Measurement, Probe Number = 1, T = 20.014000 C 09:51:14 Temperature Measurement, Probe Number = 2, T = 19.989000 C 09:51:14 Temperature Measurement, Probe Number = 3, T = 19.969000 C 09:51:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 09:51:15 Integrated Voltage Measurement... 09:51:34 Voltage Offset Correction: v_off_ini = 0.000000764 V, v_off_fin = 0.000005684 V 09:51:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428463 Vs 09:51:34 Integrated Voltage Measurement... 09:51:53 Voltage Offset Correction: v_off_ini = 0.000005361 V, v_off_fin = -0.000001912 V 09:51:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312122 Vs 10:21:56 Temperature Measurement, Probe Number = 0, T = 20.395000 C 10:21:57 Temperature Measurement, Probe Number = 1, T = 20.018000 C 10:21:58 Temperature Measurement, Probe Number = 2, T = 19.992000 C 10:21:58 Temperature Measurement, Probe Number = 3, T = 19.972000 C 10:21:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 10:21:58 Integrated Voltage Measurement... 10:22:18 Voltage Offset Correction: v_off_ini = 0.000003377 V, v_off_fin = 0.000005446 V 10:22:18 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175528868 Vs 10:22:18 Integrated Voltage Measurement... 10:22:37 Voltage Offset Correction: v_off_ini = 0.000004811 V, v_off_fin = -0.000002446 V 10:22:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309946 Vs 10:22:40 Temperature Measurement, Probe Number = 0, T = 20.377000 C 10:22:41 Temperature Measurement, Probe Number = 1, T = 20.019000 C 10:22:42 Temperature Measurement, Probe Number = 2, T = 19.991000 C 10:22:42 Temperature Measurement, Probe Number = 3, T = 19.972000 C 10:22:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 10:22:42 Integrated Voltage Measurement... 10:23:01 Voltage Offset Correction: v_off_ini = 0.000000954 V, v_off_fin = 0.000005377 V 10:23:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412749 Vs 10:23:02 Integrated Voltage Measurement... 10:23:21 Voltage Offset Correction: v_off_ini = 0.000004472 V, v_off_fin = -0.000001955 V 10:23:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305399 Vs 10:23:24 Temperature Measurement, Probe Number = 0, T = 20.373000 C 10:23:24 Temperature Measurement, Probe Number = 1, T = 20.019000 C 10:23:25 Temperature Measurement, Probe Number = 2, T = 19.993000 C 10:23:26 Temperature Measurement, Probe Number = 3, T = 19.973000 C 10:23:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 10:23:26 Integrated Voltage Measurement... 10:23:45 Voltage Offset Correction: v_off_ini = 0.000001666 V, v_off_fin = 0.000005776 V 10:23:45 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423133 Vs 10:23:45 Integrated Voltage Measurement... 10:24:05 Voltage Offset Correction: v_off_ini = 0.000004814 V, v_off_fin = -0.000003087 V 10:24:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310336 Vs 10:24:07 Temperature Measurement, Probe Number = 0, T = 20.369000 C 10:24:08 Temperature Measurement, Probe Number = 1, T = 20.021000 C 10:24:09 Temperature Measurement, Probe Number = 2, T = 19.994000 C 10:24:09 Temperature Measurement, Probe Number = 3, T = 19.975000 C 10:24:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 10:24:10 Integrated Voltage Measurement... 10:24:29 Voltage Offset Correction: v_off_ini = 0.000000853 V, v_off_fin = 0.000005995 V 10:24:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426068 Vs 10:24:29 Integrated Voltage Measurement... 10:24:49 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = -0.000002619 V 10:24:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314577 Vs 10:24:52 Temperature Measurement, Probe Number = 0, T = 20.367000 C 10:24:52 Temperature Measurement, Probe Number = 1, T = 20.022000 C 10:24:53 Temperature Measurement, Probe Number = 2, T = 19.994000 C 10:24:54 Temperature Measurement, Probe Number = 3, T = 19.976000 C 10:24:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 10:24:54 Integrated Voltage Measurement... 10:25:13 Voltage Offset Correction: v_off_ini = 0.000002118 V, v_off_fin = 0.000005999 V 10:25:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426500 Vs 10:25:13 Integrated Voltage Measurement... 10:25:33 Voltage Offset Correction: v_off_ini = 0.000005238 V, v_off_fin = -0.000001803 V 10:25:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314560 Vs 10:25:36 Temperature Measurement, Probe Number = 0, T = 20.395000 C 10:25:36 Temperature Measurement, Probe Number = 1, T = 20.021000 C 10:25:37 Temperature Measurement, Probe Number = 2, T = 19.995000 C 10:25:38 Temperature Measurement, Probe Number = 3, T = 19.977000 C 10:25:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:25:38 Integrated Voltage Measurement... 10:25:57 Voltage Offset Correction: v_off_ini = 0.000001809 V, v_off_fin = 0.000005643 V 10:25:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427661 Vs 10:25:57 Integrated Voltage Measurement... 10:26:17 Voltage Offset Correction: v_off_ini = 0.000005062 V, v_off_fin = -0.000001795 V 10:26:17 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304740 Vs 10:26:20 Temperature Measurement, Probe Number = 0, T = 20.434000 C 10:26:21 Temperature Measurement, Probe Number = 1, T = 20.021000 C 10:26:21 Temperature Measurement, Probe Number = 2, T = 19.994000 C 10:26:22 Temperature Measurement, Probe Number = 3, T = 19.976000 C 10:26:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 10:26:22 Integrated Voltage Measurement... 10:26:41 Voltage Offset Correction: v_off_ini = 0.000001359 V, v_off_fin = 0.000005176 V 10:26:41 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175408344 Vs 10:26:42 Integrated Voltage Measurement... 10:27:01 Voltage Offset Correction: v_off_ini = 0.000004223 V, v_off_fin = -0.000002820 V 10:27:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314977 Vs 10:27:04 Temperature Measurement, Probe Number = 0, T = 20.453000 C 10:27:04 Temperature Measurement, Probe Number = 1, T = 20.023000 C 10:27:05 Temperature Measurement, Probe Number = 2, T = 19.997000 C 10:27:05 Temperature Measurement, Probe Number = 3, T = 19.976000 C 10:27:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:27:06 Integrated Voltage Measurement... 10:27:25 Voltage Offset Correction: v_off_ini = 0.000000235 V, v_off_fin = 0.000004786 V 10:27:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417694 Vs 10:27:25 Integrated Voltage Measurement... 10:27:44 Voltage Offset Correction: v_off_ini = 0.000004089 V, v_off_fin = -0.000002143 V 10:27:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312553 Vs 10:27:47 Temperature Measurement, Probe Number = 0, T = 20.491000 C 10:27:48 Temperature Measurement, Probe Number = 1, T = 20.023000 C 10:27:48 Temperature Measurement, Probe Number = 2, T = 19.997000 C 10:27:49 Temperature Measurement, Probe Number = 3, T = 19.976000 C 10:27:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:27:49 Integrated Voltage Measurement... 10:28:08 Voltage Offset Correction: v_off_ini = 0.000000418 V, v_off_fin = 0.000005550 V 10:28:09 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175423495 Vs 10:28:09 Integrated Voltage Measurement... 10:28:28 Voltage Offset Correction: v_off_ini = 0.000004892 V, v_off_fin = -0.000001432 V 10:28:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175308053 Vs 10:28:31 Temperature Measurement, Probe Number = 0, T = 20.508000 C 10:28:31 Temperature Measurement, Probe Number = 1, T = 20.022000 C 10:28:32 Temperature Measurement, Probe Number = 2, T = 19.999000 C 10:28:33 Temperature Measurement, Probe Number = 3, T = 19.976000 C 10:28:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:28:33 Integrated Voltage Measurement... 10:28:52 Voltage Offset Correction: v_off_ini = 0.000000469 V, v_off_fin = 0.000005691 V 10:28:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422103 Vs 10:28:52 Integrated Voltage Measurement... 10:29:11 Voltage Offset Correction: v_off_ini = 0.000004740 V, v_off_fin = -0.000002745 V 10:29:12 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309063 Vs 10:59:14 Temperature Measurement, Probe Number = 0, T = 20.434000 C 10:59:15 Temperature Measurement, Probe Number = 1, T = 20.027000 C 10:59:16 Temperature Measurement, Probe Number = 2, T = 20.001000 C 10:59:16 Temperature Measurement, Probe Number = 3, T = 19.982000 C 10:59:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 10:59:17 Integrated Voltage Measurement... 10:59:36 Voltage Offset Correction: v_off_ini = 0.000003729 V, v_off_fin = 0.000006047 V 10:59:36 Integrated Voltage Measurement Delta Gap = 0.0040037 m VT = 0.175539280 Vs 10:59:36 Integrated Voltage Measurement... 10:59:55 Voltage Offset Correction: v_off_ini = 0.000004890 V, v_off_fin = -0.000002301 V 10:59:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295097 Vs 10:59:58 Temperature Measurement, Probe Number = 0, T = 20.430000 C 10:59:59 Temperature Measurement, Probe Number = 1, T = 20.029000 C 10:59:59 Temperature Measurement, Probe Number = 2, T = 20.002000 C 11:00:00 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:00:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:00:00 Integrated Voltage Measurement... 11:00:19 Voltage Offset Correction: v_off_ini = 0.000001415 V, v_off_fin = 0.000005535 V 11:00:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421432 Vs 11:00:20 Integrated Voltage Measurement... 11:00:39 Voltage Offset Correction: v_off_ini = 0.000004979 V, v_off_fin = -0.000002191 V 11:00:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295990 Vs 11:00:42 Temperature Measurement, Probe Number = 0, T = 20.432000 C 11:00:43 Temperature Measurement, Probe Number = 1, T = 20.029000 C 11:00:43 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:00:44 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:00:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:00:44 Integrated Voltage Measurement... 11:01:03 Voltage Offset Correction: v_off_ini = 0.000001397 V, v_off_fin = 0.000005482 V 11:01:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414296 Vs 11:01:04 Integrated Voltage Measurement... 11:01:23 Voltage Offset Correction: v_off_ini = 0.000004483 V, v_off_fin = -0.000002577 V 11:01:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311248 Vs 11:01:26 Temperature Measurement, Probe Number = 0, T = 20.425000 C 11:01:27 Temperature Measurement, Probe Number = 1, T = 20.027000 C 11:01:27 Temperature Measurement, Probe Number = 2, T = 20.002000 C 11:01:28 Temperature Measurement, Probe Number = 3, T = 19.980000 C 11:01:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:01:28 Integrated Voltage Measurement... 11:01:47 Voltage Offset Correction: v_off_ini = 0.000000423 V, v_off_fin = 0.000005288 V 11:01:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412085 Vs 11:01:48 Integrated Voltage Measurement... 11:02:07 Voltage Offset Correction: v_off_ini = 0.000004679 V, v_off_fin = -0.000002780 V 11:02:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315664 Vs 11:02:10 Temperature Measurement, Probe Number = 0, T = 20.420000 C 11:02:11 Temperature Measurement, Probe Number = 1, T = 20.028000 C 11:02:11 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:02:12 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:02:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:02:12 Integrated Voltage Measurement... 11:02:31 Voltage Offset Correction: v_off_ini = 0.000000364 V, v_off_fin = 0.000005699 V 11:02:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415542 Vs 11:02:32 Integrated Voltage Measurement... 11:02:51 Voltage Offset Correction: v_off_ini = 0.000004552 V, v_off_fin = -0.000001952 V 11:02:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308488 Vs 11:02:54 Temperature Measurement, Probe Number = 0, T = 20.452000 C 11:02:54 Temperature Measurement, Probe Number = 1, T = 20.029000 C 11:02:55 Temperature Measurement, Probe Number = 2, T = 20.002000 C 11:02:56 Temperature Measurement, Probe Number = 3, T = 19.984000 C 11:02:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:02:56 Integrated Voltage Measurement... 11:03:15 Voltage Offset Correction: v_off_ini = 0.000001099 V, v_off_fin = 0.000004976 V 11:03:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416794 Vs 11:03:16 Integrated Voltage Measurement... 11:03:35 Voltage Offset Correction: v_off_ini = 0.000004466 V, v_off_fin = -0.000002908 V 11:03:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304086 Vs 11:03:37 Temperature Measurement, Probe Number = 0, T = 20.469000 C 11:03:38 Temperature Measurement, Probe Number = 1, T = 20.027000 C 11:03:39 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:03:39 Temperature Measurement, Probe Number = 3, T = 19.983000 C 11:03:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:03:40 Integrated Voltage Measurement... 11:03:59 Voltage Offset Correction: v_off_ini = 0.000000836 V, v_off_fin = 0.000005385 V 11:03:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175414275 Vs 11:03:59 Integrated Voltage Measurement... 11:04:18 Voltage Offset Correction: v_off_ini = 0.000005243 V, v_off_fin = -0.000002531 V 11:04:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305227 Vs 11:04:21 Temperature Measurement, Probe Number = 0, T = 20.492000 C 11:04:22 Temperature Measurement, Probe Number = 1, T = 20.029000 C 11:04:23 Temperature Measurement, Probe Number = 2, T = 20.004000 C 11:04:23 Temperature Measurement, Probe Number = 3, T = 19.986000 C 11:04:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 11:04:23 Integrated Voltage Measurement... 11:04:43 Voltage Offset Correction: v_off_ini = 0.000000982 V, v_off_fin = 0.000005535 V 11:04:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418454 Vs 11:04:43 Integrated Voltage Measurement... 11:05:02 Voltage Offset Correction: v_off_ini = 0.000004991 V, v_off_fin = -0.000001795 V 11:05:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296911 Vs 11:05:05 Temperature Measurement, Probe Number = 0, T = 20.498000 C 11:05:05 Temperature Measurement, Probe Number = 1, T = 20.028000 C 11:05:06 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:05:07 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:05:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:05:07 Integrated Voltage Measurement... 11:05:26 Voltage Offset Correction: v_off_ini = 0.000001253 V, v_off_fin = 0.000005144 V 11:05:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423478 Vs 11:05:27 Integrated Voltage Measurement... 11:05:46 Voltage Offset Correction: v_off_ini = 0.000004584 V, v_off_fin = -0.000003372 V 11:05:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307169 Vs 11:05:49 Temperature Measurement, Probe Number = 0, T = 20.467000 C 11:05:49 Temperature Measurement, Probe Number = 1, T = 20.028000 C 11:05:50 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:05:51 Temperature Measurement, Probe Number = 3, T = 19.982000 C 11:05:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:05:51 Integrated Voltage Measurement... 11:06:10 Voltage Offset Correction: v_off_ini = 0.000001167 V, v_off_fin = 0.000005556 V 11:06:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416906 Vs 11:06:10 Integrated Voltage Measurement... 11:06:29 Voltage Offset Correction: v_off_ini = 0.000004367 V, v_off_fin = -0.000001764 V 11:06:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309494 Vs 11:36:32 Temperature Measurement, Probe Number = 0, T = 20.498000 C 11:36:33 Temperature Measurement, Probe Number = 1, T = 20.036000 C 11:36:34 Temperature Measurement, Probe Number = 2, T = 20.012000 C 11:36:34 Temperature Measurement, Probe Number = 3, T = 19.989000 C 11:36:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 11:36:35 Integrated Voltage Measurement... 11:36:54 Voltage Offset Correction: v_off_ini = 0.000003467 V, v_off_fin = 0.000005391 V 11:36:54 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175514283 Vs 11:36:54 Integrated Voltage Measurement... 11:37:13 Voltage Offset Correction: v_off_ini = 0.000005069 V, v_off_fin = -0.000002459 V 11:37:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303193 Vs 11:37:16 Temperature Measurement, Probe Number = 0, T = 20.498000 C 11:37:17 Temperature Measurement, Probe Number = 1, T = 20.038000 C 11:37:18 Temperature Measurement, Probe Number = 2, T = 20.013000 C 11:37:18 Temperature Measurement, Probe Number = 3, T = 19.990000 C 11:37:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 11:37:18 Integrated Voltage Measurement... 11:37:38 Voltage Offset Correction: v_off_ini = 0.000001463 V, v_off_fin = 0.000005138 V 11:37:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410618 Vs 11:37:38 Integrated Voltage Measurement... 11:37:58 Voltage Offset Correction: v_off_ini = 0.000004453 V, v_off_fin = -0.000002677 V 11:37:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307758 Vs 11:38:01 Temperature Measurement, Probe Number = 0, T = 20.503000 C 11:38:01 Temperature Measurement, Probe Number = 1, T = 20.039000 C 11:38:02 Temperature Measurement, Probe Number = 2, T = 20.015000 C 11:38:03 Temperature Measurement, Probe Number = 3, T = 19.991000 C 11:38:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:38:03 Integrated Voltage Measurement... 11:38:23 Voltage Offset Correction: v_off_ini = 0.000001465 V, v_off_fin = 0.000005368 V 11:38:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419304 Vs 11:38:23 Integrated Voltage Measurement... 11:38:43 Voltage Offset Correction: v_off_ini = 0.000004886 V, v_off_fin = -0.000002546 V 11:38:43 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175303561 Vs 11:38:46 Temperature Measurement, Probe Number = 0, T = 20.482000 C 11:38:46 Temperature Measurement, Probe Number = 1, T = 20.038000 C 11:38:47 Temperature Measurement, Probe Number = 2, T = 20.015000 C 11:38:48 Temperature Measurement, Probe Number = 3, T = 19.988000 C 11:38:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:38:48 Integrated Voltage Measurement... 11:39:07 Voltage Offset Correction: v_off_ini = 0.000000413 V, v_off_fin = 0.000004771 V 11:39:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407571 Vs 11:39:07 Integrated Voltage Measurement... 11:39:27 Voltage Offset Correction: v_off_ini = 0.000004297 V, v_off_fin = -0.000003467 V 11:39:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308762 Vs 11:39:29 Temperature Measurement, Probe Number = 0, T = 20.539000 C 11:39:30 Temperature Measurement, Probe Number = 1, T = 20.040000 C 11:39:31 Temperature Measurement, Probe Number = 2, T = 20.015000 C 11:39:31 Temperature Measurement, Probe Number = 3, T = 19.993000 C 11:39:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.54 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:39:32 Integrated Voltage Measurement... 11:39:51 Voltage Offset Correction: v_off_ini = 0.000001132 V, v_off_fin = 0.000005377 V 11:39:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416755 Vs 11:39:52 Integrated Voltage Measurement... 11:40:11 Voltage Offset Correction: v_off_ini = 0.000004203 V, v_off_fin = -0.000003222 V 11:40:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302147 Vs 11:40:14 Temperature Measurement, Probe Number = 0, T = 20.551000 C 11:40:15 Temperature Measurement, Probe Number = 1, T = 20.041000 C 11:40:15 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:40:16 Temperature Measurement, Probe Number = 3, T = 19.992000 C 11:40:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.55 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:40:16 Integrated Voltage Measurement... 11:40:35 Voltage Offset Correction: v_off_ini = 0.000000630 V, v_off_fin = 0.000005316 V 11:40:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416432 Vs 11:40:36 Integrated Voltage Measurement... 11:40:55 Voltage Offset Correction: v_off_ini = 0.000004902 V, v_off_fin = -0.000002347 V 11:40:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301673 Vs 11:40:57 Temperature Measurement, Probe Number = 0, T = 20.524000 C 11:40:58 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:40:59 Temperature Measurement, Probe Number = 2, T = 20.017000 C 11:40:59 Temperature Measurement, Probe Number = 3, T = 19.994000 C 11:40:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.52 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:41:00 Integrated Voltage Measurement... 11:41:19 Voltage Offset Correction: v_off_ini = 0.000001726 V, v_off_fin = 0.000005498 V 11:41:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420270 Vs 11:41:19 Integrated Voltage Measurement... 11:41:39 Voltage Offset Correction: v_off_ini = 0.000004528 V, v_off_fin = -0.000002788 V 11:41:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311429 Vs 11:41:42 Temperature Measurement, Probe Number = 0, T = 20.511000 C 11:41:42 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:41:43 Temperature Measurement, Probe Number = 2, T = 20.018000 C 11:41:44 Temperature Measurement, Probe Number = 3, T = 19.995000 C 11:41:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 11:41:44 Integrated Voltage Measurement... 11:42:04 Voltage Offset Correction: v_off_ini = 0.000000344 V, v_off_fin = 0.000004881 V 11:42:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414940 Vs 11:42:04 Integrated Voltage Measurement... 11:42:24 Voltage Offset Correction: v_off_ini = 0.000004697 V, v_off_fin = -0.000001455 V 11:42:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175299047 Vs 11:42:27 Temperature Measurement, Probe Number = 0, T = 20.505000 C 11:42:27 Temperature Measurement, Probe Number = 1, T = 20.043000 C 11:42:28 Temperature Measurement, Probe Number = 2, T = 20.017000 C 11:42:29 Temperature Measurement, Probe Number = 3, T = 19.996000 C 11:42:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 11:42:29 Integrated Voltage Measurement... 11:42:49 Voltage Offset Correction: v_off_ini = 0.000001536 V, v_off_fin = 0.000005738 V 11:42:49 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417330 Vs 11:42:49 Integrated Voltage Measurement... 11:43:08 Voltage Offset Correction: v_off_ini = 0.000004933 V, v_off_fin = -0.000002009 V 11:43:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295411 Vs 11:43:11 Temperature Measurement, Probe Number = 0, T = 20.484000 C 11:43:12 Temperature Measurement, Probe Number = 1, T = 20.042000 C 11:43:12 Temperature Measurement, Probe Number = 2, T = 20.016000 C 11:43:13 Temperature Measurement, Probe Number = 3, T = 19.994000 C 11:43:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 11:43:13 Integrated Voltage Measurement... 11:43:32 Voltage Offset Correction: v_off_ini = 0.000001484 V, v_off_fin = 0.000005757 V 11:43:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425703 Vs 11:43:33 Integrated Voltage Measurement... 11:43:52 Voltage Offset Correction: v_off_ini = 0.000004978 V, v_off_fin = -0.000002333 V 11:43:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302160 Vs 12:13:55 Temperature Measurement, Probe Number = 0, T = 20.255000 C 12:13:56 Temperature Measurement, Probe Number = 1, T = 20.037000 C 12:13:56 Temperature Measurement, Probe Number = 2, T = 20.008000 C 12:13:57 Temperature Measurement, Probe Number = 3, T = 19.991000 C 12:13:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:13:57 Integrated Voltage Measurement... 12:14:17 Voltage Offset Correction: v_off_ini = 0.000003077 V, v_off_fin = 0.000005074 V 12:14:17 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175513772 Vs 12:14:17 Integrated Voltage Measurement... 12:14:37 Voltage Offset Correction: v_off_ini = 0.000004666 V, v_off_fin = -0.000005851 V 12:14:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317528 Vs 12:14:40 Temperature Measurement, Probe Number = 0, T = 20.234000 C 12:14:40 Temperature Measurement, Probe Number = 1, T = 20.036000 C 12:14:41 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:14:42 Temperature Measurement, Probe Number = 3, T = 19.991000 C 12:14:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:14:42 Integrated Voltage Measurement... 12:15:01 Voltage Offset Correction: v_off_ini = 0.000001412 V, v_off_fin = 0.000005372 V 12:15:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429647 Vs 12:15:01 Integrated Voltage Measurement... 12:15:21 Voltage Offset Correction: v_off_ini = 0.000004371 V, v_off_fin = -0.000002242 V 12:15:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318896 Vs 12:15:24 Temperature Measurement, Probe Number = 0, T = 20.227000 C 12:15:24 Temperature Measurement, Probe Number = 1, T = 20.037000 C 12:15:25 Temperature Measurement, Probe Number = 2, T = 20.008000 C 12:15:26 Temperature Measurement, Probe Number = 3, T = 19.990000 C 12:15:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:15:26 Integrated Voltage Measurement... 12:15:45 Voltage Offset Correction: v_off_ini = 0.000000960 V, v_off_fin = 0.000005736 V 12:15:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427243 Vs 12:15:45 Integrated Voltage Measurement... 12:16:05 Voltage Offset Correction: v_off_ini = 0.000004879 V, v_off_fin = -0.000002007 V 12:16:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175317501 Vs 12:16:08 Temperature Measurement, Probe Number = 0, T = 20.270000 C 12:16:09 Temperature Measurement, Probe Number = 1, T = 20.039000 C 12:16:09 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:16:10 Temperature Measurement, Probe Number = 3, T = 19.993000 C 12:16:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:16:10 Integrated Voltage Measurement... 12:16:29 Voltage Offset Correction: v_off_ini = 0.000001105 V, v_off_fin = 0.000004862 V 12:16:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422406 Vs 12:16:30 Integrated Voltage Measurement... 12:16:49 Voltage Offset Correction: v_off_ini = 0.000004806 V, v_off_fin = -0.000002172 V 12:16:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323772 Vs 12:16:52 Temperature Measurement, Probe Number = 0, T = 20.336000 C 12:16:53 Temperature Measurement, Probe Number = 1, T = 20.040000 C 12:16:53 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:16:54 Temperature Measurement, Probe Number = 3, T = 19.991000 C 12:16:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:16:54 Integrated Voltage Measurement... 12:17:13 Voltage Offset Correction: v_off_ini = 0.000000386 V, v_off_fin = 0.000005952 V 12:17:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424545 Vs 12:17:13 Integrated Voltage Measurement... 12:17:32 Voltage Offset Correction: v_off_ini = 0.000004647 V, v_off_fin = -0.000002832 V 12:17:33 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314970 Vs 12:17:35 Temperature Measurement, Probe Number = 0, T = 20.350000 C 12:17:36 Temperature Measurement, Probe Number = 1, T = 20.042000 C 12:17:37 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:17:37 Temperature Measurement, Probe Number = 3, T = 19.992000 C 12:17:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:17:38 Integrated Voltage Measurement... 12:17:57 Voltage Offset Correction: v_off_ini = 0.000000841 V, v_off_fin = 0.000005340 V 12:17:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433021 Vs 12:17:57 Integrated Voltage Measurement... 12:18:16 Voltage Offset Correction: v_off_ini = 0.000004947 V, v_off_fin = -0.000002434 V 12:18:17 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309886 Vs 12:18:19 Temperature Measurement, Probe Number = 0, T = 20.371000 C 12:18:20 Temperature Measurement, Probe Number = 1, T = 20.043000 C 12:18:21 Temperature Measurement, Probe Number = 2, T = 20.012000 C 12:18:21 Temperature Measurement, Probe Number = 3, T = 19.994000 C 12:18:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:18:21 Integrated Voltage Measurement... 12:18:40 Voltage Offset Correction: v_off_ini = 0.000001055 V, v_off_fin = 0.000005571 V 12:18:41 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175427715 Vs 12:18:41 Integrated Voltage Measurement... 12:19:00 Voltage Offset Correction: v_off_ini = 0.000004763 V, v_off_fin = -0.000002523 V 12:19:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313185 Vs 12:19:03 Temperature Measurement, Probe Number = 0, T = 20.385000 C 12:19:03 Temperature Measurement, Probe Number = 1, T = 20.045000 C 12:19:04 Temperature Measurement, Probe Number = 2, T = 20.017000 C 12:19:05 Temperature Measurement, Probe Number = 3, T = 19.994000 C 12:19:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:19:05 Integrated Voltage Measurement... 12:19:24 Voltage Offset Correction: v_off_ini = 0.000001385 V, v_off_fin = 0.000006027 V 12:19:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431134 Vs 12:19:24 Integrated Voltage Measurement... 12:19:44 Voltage Offset Correction: v_off_ini = 0.000004763 V, v_off_fin = -0.000001680 V 12:19:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306485 Vs 12:19:46 Temperature Measurement, Probe Number = 0, T = 20.398000 C 12:19:47 Temperature Measurement, Probe Number = 1, T = 20.046000 C 12:19:48 Temperature Measurement, Probe Number = 2, T = 20.015000 C 12:19:48 Temperature Measurement, Probe Number = 3, T = 19.998000 C 12:19:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 12:19:49 Integrated Voltage Measurement... 12:20:08 Voltage Offset Correction: v_off_ini = 0.000001255 V, v_off_fin = 0.000006435 V 12:20:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434352 Vs 12:20:08 Integrated Voltage Measurement... 12:20:27 Voltage Offset Correction: v_off_ini = 0.000005866 V, v_off_fin = -0.000001480 V 12:20:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316475 Vs 12:20:30 Temperature Measurement, Probe Number = 0, T = 20.430000 C 12:20:31 Temperature Measurement, Probe Number = 1, T = 20.044000 C 12:20:31 Temperature Measurement, Probe Number = 2, T = 20.016000 C 12:20:32 Temperature Measurement, Probe Number = 3, T = 19.996000 C 12:20:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 12:20:32 Integrated Voltage Measurement... 12:20:52 Voltage Offset Correction: v_off_ini = 0.000001861 V, v_off_fin = 0.000006126 V 12:20:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438604 Vs 12:20:52 Integrated Voltage Measurement... 12:21:11 Voltage Offset Correction: v_off_ini = 0.000005313 V, v_off_fin = -0.000001559 V 12:21:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312224 Vs 12:51:14 Temperature Measurement, Probe Number = 0, T = 20.410000 C 12:51:15 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:51:16 Temperature Measurement, Probe Number = 2, T = 20.016000 C 12:51:16 Temperature Measurement, Probe Number = 3, T = 19.994000 C 12:51:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:51:17 Integrated Voltage Measurement... 12:51:36 Voltage Offset Correction: v_off_ini = 0.000003049 V, v_off_fin = 0.000005798 V 12:51:36 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175511456 Vs 12:51:36 Integrated Voltage Measurement... 12:51:55 Voltage Offset Correction: v_off_ini = 0.000005139 V, v_off_fin = -0.000001756 V 12:51:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313024 Vs 12:51:58 Temperature Measurement, Probe Number = 0, T = 20.393000 C 12:51:59 Temperature Measurement, Probe Number = 1, T = 20.044000 C 12:52:00 Temperature Measurement, Probe Number = 2, T = 20.018000 C 12:52:00 Temperature Measurement, Probe Number = 3, T = 19.992000 C 12:52:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:52:01 Integrated Voltage Measurement... 12:52:20 Voltage Offset Correction: v_off_ini = 0.000001190 V, v_off_fin = 0.000005452 V 12:52:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417062 Vs 12:52:20 Integrated Voltage Measurement... 12:52:39 Voltage Offset Correction: v_off_ini = 0.000004942 V, v_off_fin = -0.000002870 V 12:52:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320457 Vs 12:52:42 Temperature Measurement, Probe Number = 0, T = 20.370000 C 12:52:43 Temperature Measurement, Probe Number = 1, T = 20.046000 C 12:52:43 Temperature Measurement, Probe Number = 2, T = 20.018000 C 12:52:44 Temperature Measurement, Probe Number = 3, T = 19.994000 C 12:52:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:52:44 Integrated Voltage Measurement... 12:53:04 Voltage Offset Correction: v_off_ini = 0.000001882 V, v_off_fin = 0.000005702 V 12:53:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425227 Vs 12:53:04 Integrated Voltage Measurement... 12:53:24 Voltage Offset Correction: v_off_ini = 0.000004366 V, v_off_fin = -0.000002339 V 12:53:24 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313582 Vs 12:53:26 Temperature Measurement, Probe Number = 0, T = 20.356000 C 12:53:27 Temperature Measurement, Probe Number = 1, T = 20.041000 C 12:53:28 Temperature Measurement, Probe Number = 2, T = 20.017000 C 12:53:28 Temperature Measurement, Probe Number = 3, T = 19.992000 C 12:53:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:53:29 Integrated Voltage Measurement... 12:53:48 Voltage Offset Correction: v_off_ini = 0.000001111 V, v_off_fin = 0.000005635 V 12:53:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413165 Vs 12:53:48 Integrated Voltage Measurement... 12:54:07 Voltage Offset Correction: v_off_ini = 0.000004916 V, v_off_fin = -0.000003206 V 12:54:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323969 Vs 12:54:10 Temperature Measurement, Probe Number = 0, T = 20.317000 C 12:54:11 Temperature Measurement, Probe Number = 1, T = 20.042000 C 12:54:12 Temperature Measurement, Probe Number = 2, T = 20.016000 C 12:54:12 Temperature Measurement, Probe Number = 3, T = 19.993000 C 12:54:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 12:54:12 Integrated Voltage Measurement... 12:54:32 Voltage Offset Correction: v_off_ini = 0.000001349 V, v_off_fin = 0.000005671 V 12:54:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432833 Vs 12:54:32 Integrated Voltage Measurement... 12:54:51 Voltage Offset Correction: v_off_ini = 0.000004810 V, v_off_fin = -0.000002552 V 12:54:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313054 Vs 12:54:54 Temperature Measurement, Probe Number = 0, T = 20.334000 C 12:54:54 Temperature Measurement, Probe Number = 1, T = 20.043000 C 12:54:55 Temperature Measurement, Probe Number = 2, T = 20.017000 C 12:54:56 Temperature Measurement, Probe Number = 3, T = 19.996000 C 12:54:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 12:54:56 Integrated Voltage Measurement... 12:55:15 Voltage Offset Correction: v_off_ini = 0.000000837 V, v_off_fin = 0.000005820 V 12:55:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426803 Vs 12:55:15 Integrated Voltage Measurement... 12:55:35 Voltage Offset Correction: v_off_ini = 0.000004807 V, v_off_fin = -0.000001830 V 12:55:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314625 Vs 12:55:37 Temperature Measurement, Probe Number = 0, T = 20.303000 C 12:55:38 Temperature Measurement, Probe Number = 1, T = 20.044000 C 12:55:39 Temperature Measurement, Probe Number = 2, T = 20.018000 C 12:55:39 Temperature Measurement, Probe Number = 3, T = 19.997000 C 12:55:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 12:55:40 Integrated Voltage Measurement... 12:55:59 Voltage Offset Correction: v_off_ini = 0.000001216 V, v_off_fin = 0.000005764 V 12:55:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428476 Vs 12:55:59 Integrated Voltage Measurement... 12:56:19 Voltage Offset Correction: v_off_ini = 0.000005136 V, v_off_fin = -0.000002346 V 12:56:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314530 Vs 12:56:21 Temperature Measurement, Probe Number = 0, T = 20.299000 C 12:56:22 Temperature Measurement, Probe Number = 1, T = 20.043000 C 12:56:23 Temperature Measurement, Probe Number = 2, T = 20.014000 C 12:56:23 Temperature Measurement, Probe Number = 3, T = 19.993000 C 12:56:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:56:24 Integrated Voltage Measurement... 12:56:43 Voltage Offset Correction: v_off_ini = 0.000001162 V, v_off_fin = 0.000006387 V 12:56:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432707 Vs 12:56:43 Integrated Voltage Measurement... 12:57:02 Voltage Offset Correction: v_off_ini = 0.000005203 V, v_off_fin = -0.000001550 V 12:57:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309867 Vs 12:57:05 Temperature Measurement, Probe Number = 0, T = 20.281000 C 12:57:06 Temperature Measurement, Probe Number = 1, T = 20.042000 C 12:57:06 Temperature Measurement, Probe Number = 2, T = 20.011000 C 12:57:07 Temperature Measurement, Probe Number = 3, T = 19.990000 C 12:57:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:57:07 Integrated Voltage Measurement... 12:57:26 Voltage Offset Correction: v_off_ini = 0.000001879 V, v_off_fin = 0.000006216 V 12:57:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441944 Vs 12:57:27 Integrated Voltage Measurement... 12:57:46 Voltage Offset Correction: v_off_ini = 0.000005345 V, v_off_fin = -0.000001632 V 12:57:46 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175322646 Vs 12:57:49 Temperature Measurement, Probe Number = 0, T = 20.256000 C 12:57:50 Temperature Measurement, Probe Number = 1, T = 20.044000 C 12:57:50 Temperature Measurement, Probe Number = 2, T = 20.014000 C 12:57:51 Temperature Measurement, Probe Number = 3, T = 19.991000 C 12:57:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:57:51 Integrated Voltage Measurement... 12:58:10 Voltage Offset Correction: v_off_ini = 0.000001882 V, v_off_fin = 0.000006224 V 12:58:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440224 Vs 12:58:11 Integrated Voltage Measurement... 12:58:30 Voltage Offset Correction: v_off_ini = 0.000005699 V, v_off_fin = -0.000001998 V 12:58:30 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309119 Vs 13:28:33 Temperature Measurement, Probe Number = 0, T = 20.351000 C 13:28:33 Temperature Measurement, Probe Number = 1, T = 20.052000 C 13:28:34 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:28:35 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:28:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:28:35 Integrated Voltage Measurement... 13:28:54 Voltage Offset Correction: v_off_ini = 0.000003634 V, v_off_fin = 0.000005355 V 13:28:54 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175532523 Vs 13:28:55 Integrated Voltage Measurement... 13:29:14 Voltage Offset Correction: v_off_ini = 0.000005051 V, v_off_fin = -0.000002788 V 13:29:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308459 Vs 13:29:17 Temperature Measurement, Probe Number = 0, T = 20.368000 C 13:29:17 Temperature Measurement, Probe Number = 1, T = 20.052000 C 13:29:18 Temperature Measurement, Probe Number = 2, T = 20.027000 C 13:29:19 Temperature Measurement, Probe Number = 3, T = 19.999000 C 13:29:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:29:19 Integrated Voltage Measurement... 13:29:39 Voltage Offset Correction: v_off_ini = 0.000000833 V, v_off_fin = 0.000005437 V 13:29:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425229 Vs 13:29:39 Integrated Voltage Measurement... 13:29:58 Voltage Offset Correction: v_off_ini = 0.000005027 V, v_off_fin = -0.000002817 V 13:29:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308339 Vs 13:30:01 Temperature Measurement, Probe Number = 0, T = 20.418000 C 13:30:02 Temperature Measurement, Probe Number = 1, T = 20.051000 C 13:30:02 Temperature Measurement, Probe Number = 2, T = 20.028000 C 13:30:03 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:30:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:30:03 Integrated Voltage Measurement... 13:30:22 Voltage Offset Correction: v_off_ini = 0.000001205 V, v_off_fin = 0.000006192 V 13:30:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429831 Vs 13:30:23 Integrated Voltage Measurement... 13:30:42 Voltage Offset Correction: v_off_ini = 0.000005229 V, v_off_fin = -0.000002497 V 13:30:42 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175306674 Vs 13:30:45 Temperature Measurement, Probe Number = 0, T = 20.387000 C 13:30:45 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:30:46 Temperature Measurement, Probe Number = 2, T = 20.026000 C 13:30:47 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:30:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:30:47 Integrated Voltage Measurement... 13:31:06 Voltage Offset Correction: v_off_ini = 0.000000721 V, v_off_fin = 0.000005257 V 13:31:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425579 Vs 13:31:07 Integrated Voltage Measurement... 13:31:26 Voltage Offset Correction: v_off_ini = 0.000004885 V, v_off_fin = -0.000002926 V 13:31:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319719 Vs 13:31:29 Temperature Measurement, Probe Number = 0, T = 20.366000 C 13:31:30 Temperature Measurement, Probe Number = 1, T = 20.050000 C 13:31:30 Temperature Measurement, Probe Number = 2, T = 20.026000 C 13:31:31 Temperature Measurement, Probe Number = 3, T = 20.001000 C 13:31:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:31:31 Integrated Voltage Measurement... 13:31:50 Voltage Offset Correction: v_off_ini = 0.000001003 V, v_off_fin = 0.000005772 V 13:31:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423611 Vs 13:31:50 Integrated Voltage Measurement... 13:32:09 Voltage Offset Correction: v_off_ini = 0.000005202 V, v_off_fin = -0.000003002 V 13:32:10 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175311163 Vs 13:32:12 Temperature Measurement, Probe Number = 0, T = 20.334000 C 13:32:13 Temperature Measurement, Probe Number = 1, T = 20.048000 C 13:32:14 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:32:14 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:32:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:32:14 Integrated Voltage Measurement... 13:32:33 Voltage Offset Correction: v_off_ini = 0.000001130 V, v_off_fin = 0.000005599 V 13:32:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430121 Vs 13:32:34 Integrated Voltage Measurement... 13:32:53 Voltage Offset Correction: v_off_ini = 0.000005338 V, v_off_fin = -0.000003001 V 13:32:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312304 Vs 13:32:56 Temperature Measurement, Probe Number = 0, T = 20.333000 C 13:32:56 Temperature Measurement, Probe Number = 1, T = 20.048000 C 13:32:57 Temperature Measurement, Probe Number = 2, T = 20.024000 C 13:32:58 Temperature Measurement, Probe Number = 3, T = 20.001000 C 13:32:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:32:58 Integrated Voltage Measurement... 13:33:17 Voltage Offset Correction: v_off_ini = 0.000001079 V, v_off_fin = 0.000005746 V 13:33:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433339 Vs 13:33:18 Integrated Voltage Measurement... 13:33:37 Voltage Offset Correction: v_off_ini = 0.000004921 V, v_off_fin = -0.000002181 V 13:33:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175339160 Vs 13:33:40 Temperature Measurement, Probe Number = 0, T = 20.333000 C 13:33:41 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:33:42 Temperature Measurement, Probe Number = 2, T = 20.023000 C 13:33:42 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:33:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:33:42 Integrated Voltage Measurement... 13:34:01 Voltage Offset Correction: v_off_ini = 0.000001371 V, v_off_fin = 0.000005843 V 13:34:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427493 Vs 13:34:02 Integrated Voltage Measurement... 13:34:21 Voltage Offset Correction: v_off_ini = 0.000005011 V, v_off_fin = -0.000003111 V 13:34:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312927 Vs 13:34:24 Temperature Measurement, Probe Number = 0, T = 20.278000 C 13:34:25 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:34:25 Temperature Measurement, Probe Number = 2, T = 20.022000 C 13:34:26 Temperature Measurement, Probe Number = 3, T = 19.998000 C 13:34:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:34:26 Integrated Voltage Measurement... 13:34:45 Voltage Offset Correction: v_off_ini = 0.000001020 V, v_off_fin = 0.000005536 V 13:34:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424673 Vs 13:34:46 Integrated Voltage Measurement... 13:35:05 Voltage Offset Correction: v_off_ini = 0.000004600 V, v_off_fin = -0.000002739 V 13:35:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320857 Vs 13:35:08 Temperature Measurement, Probe Number = 0, T = 20.242000 C 13:35:09 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:35:09 Temperature Measurement, Probe Number = 2, T = 20.024000 C 13:35:10 Temperature Measurement, Probe Number = 3, T = 19.998000 C 13:35:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:35:10 Integrated Voltage Measurement... 13:35:29 Voltage Offset Correction: v_off_ini = 0.000001129 V, v_off_fin = 0.000006043 V 13:35:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429413 Vs 13:35:30 Integrated Voltage Measurement... 13:35:49 Voltage Offset Correction: v_off_ini = 0.000004855 V, v_off_fin = -0.000002488 V 13:35:49 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175313132 Vs 14:05:51 Temperature Measurement, Probe Number = 0, T = 20.339000 C 14:05:52 Temperature Measurement, Probe Number = 1, T = 20.052000 C 14:05:53 Temperature Measurement, Probe Number = 2, T = 20.026000 C 14:05:53 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:05:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:05:54 Integrated Voltage Measurement... 14:06:12 Voltage Offset Correction: v_off_ini = 0.000003251 V, v_off_fin = 0.000005475 V 14:06:13 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175524149 Vs 14:06:13 Integrated Voltage Measurement... 14:06:32 Voltage Offset Correction: v_off_ini = 0.000005260 V, v_off_fin = -0.000003149 V 14:06:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305516 Vs 14:06:35 Temperature Measurement, Probe Number = 0, T = 20.384000 C 14:06:36 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:06:36 Temperature Measurement, Probe Number = 2, T = 20.028000 C 14:06:37 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:06:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:06:37 Integrated Voltage Measurement... 14:06:57 Voltage Offset Correction: v_off_ini = 0.000001310 V, v_off_fin = 0.000005458 V 14:06:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419378 Vs 14:06:57 Integrated Voltage Measurement... 14:07:16 Voltage Offset Correction: v_off_ini = 0.000005205 V, v_off_fin = -0.000002587 V 14:07:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299230 Vs 14:07:19 Temperature Measurement, Probe Number = 0, T = 20.392000 C 14:07:20 Temperature Measurement, Probe Number = 1, T = 20.055000 C 14:07:20 Temperature Measurement, Probe Number = 2, T = 20.031000 C 14:07:21 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:07:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:07:21 Integrated Voltage Measurement... 14:07:41 Voltage Offset Correction: v_off_ini = 0.000000658 V, v_off_fin = 0.000005204 V 14:07:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418328 Vs 14:07:41 Integrated Voltage Measurement... 14:08:00 Voltage Offset Correction: v_off_ini = 0.000005085 V, v_off_fin = -0.000001946 V 14:08:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305057 Vs 14:08:03 Temperature Measurement, Probe Number = 0, T = 20.406000 C 14:08:04 Temperature Measurement, Probe Number = 1, T = 20.057000 C 14:08:04 Temperature Measurement, Probe Number = 2, T = 20.030000 C 14:08:05 Temperature Measurement, Probe Number = 3, T = 20.007000 C 14:08:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:08:05 Integrated Voltage Measurement... 14:08:25 Voltage Offset Correction: v_off_ini = 0.000001470 V, v_off_fin = 0.000005882 V 14:08:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423196 Vs 14:08:25 Integrated Voltage Measurement... 14:08:44 Voltage Offset Correction: v_off_ini = 0.000005002 V, v_off_fin = -0.000002827 V 14:08:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312696 Vs 14:08:47 Temperature Measurement, Probe Number = 0, T = 20.409000 C 14:08:48 Temperature Measurement, Probe Number = 1, T = 20.057000 C 14:08:49 Temperature Measurement, Probe Number = 2, T = 20.030000 C 14:08:49 Temperature Measurement, Probe Number = 3, T = 20.006000 C 14:08:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:08:49 Integrated Voltage Measurement... 14:09:09 Voltage Offset Correction: v_off_ini = 0.000001207 V, v_off_fin = 0.000005673 V 14:09:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420936 Vs 14:09:09 Integrated Voltage Measurement... 14:09:28 Voltage Offset Correction: v_off_ini = 0.000004930 V, v_off_fin = -0.000002495 V 14:09:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311330 Vs 14:09:31 Temperature Measurement, Probe Number = 0, T = 20.461000 C 14:09:32 Temperature Measurement, Probe Number = 1, T = 20.055000 C 14:09:33 Temperature Measurement, Probe Number = 2, T = 20.033000 C 14:09:33 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:09:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:09:33 Integrated Voltage Measurement... 14:09:53 Voltage Offset Correction: v_off_ini = 0.000000633 V, v_off_fin = 0.000006099 V 14:09:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428327 Vs 14:09:53 Integrated Voltage Measurement... 14:10:12 Voltage Offset Correction: v_off_ini = 0.000005200 V, v_off_fin = -0.000002206 V 14:10:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304664 Vs 14:10:15 Temperature Measurement, Probe Number = 0, T = 20.409000 C 14:10:15 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:10:16 Temperature Measurement, Probe Number = 2, T = 20.033000 C 14:10:17 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:10:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:10:17 Integrated Voltage Measurement... 14:10:36 Voltage Offset Correction: v_off_ini = 0.000001448 V, v_off_fin = 0.000005863 V 14:10:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431637 Vs 14:10:36 Integrated Voltage Measurement... 14:10:55 Voltage Offset Correction: v_off_ini = 0.000004762 V, v_off_fin = -0.000002232 V 14:10:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317037 Vs 14:10:58 Temperature Measurement, Probe Number = 0, T = 20.392000 C 14:10:59 Temperature Measurement, Probe Number = 1, T = 20.053000 C 14:11:00 Temperature Measurement, Probe Number = 2, T = 20.029000 C 14:11:00 Temperature Measurement, Probe Number = 3, T = 20.002000 C 14:11:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:11:00 Integrated Voltage Measurement... 14:11:19 Voltage Offset Correction: v_off_ini = 0.000000512 V, v_off_fin = 0.000005064 V 14:11:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419954 Vs 14:11:20 Integrated Voltage Measurement... 14:11:39 Voltage Offset Correction: v_off_ini = 0.000004816 V, v_off_fin = -0.000001656 V 14:11:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309776 Vs 14:11:42 Temperature Measurement, Probe Number = 0, T = 20.343000 C 14:11:43 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:11:44 Temperature Measurement, Probe Number = 2, T = 20.029000 C 14:11:44 Temperature Measurement, Probe Number = 3, T = 20.003000 C 14:11:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:11:45 Integrated Voltage Measurement... 14:12:04 Voltage Offset Correction: v_off_ini = 0.000000737 V, v_off_fin = 0.000005693 V 14:12:04 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175418367 Vs 14:12:04 Integrated Voltage Measurement... 14:12:23 Voltage Offset Correction: v_off_ini = 0.000004972 V, v_off_fin = -0.000002976 V 14:12:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306767 Vs 14:12:26 Temperature Measurement, Probe Number = 0, T = 20.341000 C 14:12:27 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:12:27 Temperature Measurement, Probe Number = 2, T = 20.029000 C 14:12:28 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:12:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:12:28 Integrated Voltage Measurement... 14:12:47 Voltage Offset Correction: v_off_ini = 0.000001392 V, v_off_fin = 0.000005686 V 14:12:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430813 Vs 14:12:47 Integrated Voltage Measurement... 14:13:07 Voltage Offset Correction: v_off_ini = 0.000004899 V, v_off_fin = -0.000002480 V 14:13:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318094 Vs 14:43:09 Temperature Measurement, Probe Number = 0, T = 20.340000 C 14:43:10 Temperature Measurement, Probe Number = 1, T = 20.059000 C 14:43:11 Temperature Measurement, Probe Number = 2, T = 20.033000 C 14:43:11 Temperature Measurement, Probe Number = 3, T = 20.008000 C 14:43:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:43:12 Integrated Voltage Measurement... 14:43:31 Voltage Offset Correction: v_off_ini = 0.000003548 V, v_off_fin = 0.000005902 V 14:43:31 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175527025 Vs 14:43:31 Integrated Voltage Measurement... 14:43:51 Voltage Offset Correction: v_off_ini = 0.000005307 V, v_off_fin = -0.000001789 V 14:43:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299057 Vs 14:43:53 Temperature Measurement, Probe Number = 0, T = 20.291000 C 14:43:54 Temperature Measurement, Probe Number = 1, T = 20.061000 C 14:43:55 Temperature Measurement, Probe Number = 2, T = 20.034000 C 14:43:55 Temperature Measurement, Probe Number = 3, T = 20.010000 C 14:43:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:43:56 Integrated Voltage Measurement... 14:44:15 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = 0.000005910 V 14:44:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427414 Vs 14:44:15 Integrated Voltage Measurement... 14:44:35 Voltage Offset Correction: v_off_ini = 0.000005342 V, v_off_fin = -0.000002123 V 14:44:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311206 Vs 14:44:38 Temperature Measurement, Probe Number = 0, T = 20.292000 C 14:44:38 Temperature Measurement, Probe Number = 1, T = 20.061000 C 14:44:39 Temperature Measurement, Probe Number = 2, T = 20.033000 C 14:44:40 Temperature Measurement, Probe Number = 3, T = 20.010000 C 14:44:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:44:40 Integrated Voltage Measurement... 14:44:59 Voltage Offset Correction: v_off_ini = 0.000002301 V, v_off_fin = 0.000005639 V 14:44:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423410 Vs 14:44:59 Integrated Voltage Measurement... 14:45:19 Voltage Offset Correction: v_off_ini = 0.000005182 V, v_off_fin = -0.000002080 V 14:45:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310878 Vs 14:45:22 Temperature Measurement, Probe Number = 0, T = 20.275000 C 14:45:22 Temperature Measurement, Probe Number = 1, T = 20.056000 C 14:45:23 Temperature Measurement, Probe Number = 2, T = 20.026000 C 14:45:24 Temperature Measurement, Probe Number = 3, T = 20.007000 C 14:45:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:45:24 Integrated Voltage Measurement... 14:45:43 Voltage Offset Correction: v_off_ini = 0.000001518 V, v_off_fin = 0.000005837 V 14:45:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422006 Vs 14:45:44 Integrated Voltage Measurement... 14:46:03 Voltage Offset Correction: v_off_ini = 0.000004602 V, v_off_fin = -0.000002273 V 14:46:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312335 Vs 14:46:06 Temperature Measurement, Probe Number = 0, T = 20.295000 C 14:46:07 Temperature Measurement, Probe Number = 1, T = 20.055000 C 14:46:07 Temperature Measurement, Probe Number = 2, T = 20.029000 C 14:46:08 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:46:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:46:08 Integrated Voltage Measurement... 14:46:27 Voltage Offset Correction: v_off_ini = 0.000001164 V, v_off_fin = 0.000005180 V 14:46:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419616 Vs 14:46:27 Integrated Voltage Measurement... 14:46:47 Voltage Offset Correction: v_off_ini = 0.000004716 V, v_off_fin = -0.000002887 V 14:46:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320182 Vs 14:46:50 Temperature Measurement, Probe Number = 0, T = 20.255000 C 14:46:50 Temperature Measurement, Probe Number = 1, T = 20.053000 C 14:46:51 Temperature Measurement, Probe Number = 2, T = 20.026000 C 14:46:52 Temperature Measurement, Probe Number = 3, T = 20.006000 C 14:46:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:46:52 Integrated Voltage Measurement... 14:47:11 Voltage Offset Correction: v_off_ini = 0.000000617 V, v_off_fin = 0.000005913 V 14:47:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420305 Vs 14:47:11 Integrated Voltage Measurement... 14:47:30 Voltage Offset Correction: v_off_ini = 0.000005179 V, v_off_fin = -0.000002234 V 14:47:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306786 Vs 14:47:33 Temperature Measurement, Probe Number = 0, T = 20.245000 C 14:47:34 Temperature Measurement, Probe Number = 1, T = 20.050000 C 14:47:35 Temperature Measurement, Probe Number = 2, T = 20.022000 C 14:47:35 Temperature Measurement, Probe Number = 3, T = 20.001000 C 14:47:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 14:47:35 Integrated Voltage Measurement... 14:47:55 Voltage Offset Correction: v_off_ini = 0.000001051 V, v_off_fin = 0.000005699 V 14:47:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421812 Vs 14:47:55 Integrated Voltage Measurement... 14:48:15 Voltage Offset Correction: v_off_ini = 0.000005056 V, v_off_fin = -0.000002668 V 14:48:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317983 Vs 14:48:18 Temperature Measurement, Probe Number = 0, T = 20.205000 C 14:48:18 Temperature Measurement, Probe Number = 1, T = 20.052000 C 14:48:19 Temperature Measurement, Probe Number = 2, T = 20.020000 C 14:48:20 Temperature Measurement, Probe Number = 3, T = 20.005000 C 14:48:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 14:48:20 Integrated Voltage Measurement... 14:48:39 Voltage Offset Correction: v_off_ini = 0.000000827 V, v_off_fin = 0.000006301 V 14:48:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431042 Vs 14:48:39 Integrated Voltage Measurement... 14:48:58 Voltage Offset Correction: v_off_ini = 0.000005677 V, v_off_fin = -0.000002549 V 14:48:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308109 Vs 14:49:01 Temperature Measurement, Probe Number = 0, T = 20.221000 C 14:49:02 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:49:03 Temperature Measurement, Probe Number = 2, T = 20.025000 C 14:49:03 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:49:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 14:49:03 Integrated Voltage Measurement... 14:49:22 Voltage Offset Correction: v_off_ini = 0.000001672 V, v_off_fin = 0.000005633 V 14:49:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425769 Vs 14:49:23 Integrated Voltage Measurement... 14:49:42 Voltage Offset Correction: v_off_ini = 0.000004950 V, v_off_fin = -0.000002483 V 14:49:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307009 Vs 14:49:45 Temperature Measurement, Probe Number = 0, T = 20.266000 C 14:49:45 Temperature Measurement, Probe Number = 1, T = 20.054000 C 14:49:46 Temperature Measurement, Probe Number = 2, T = 20.026000 C 14:49:46 Temperature Measurement, Probe Number = 3, T = 20.004000 C 14:49:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 14:49:47 Integrated Voltage Measurement... 14:50:06 Voltage Offset Correction: v_off_ini = 0.000001010 V, v_off_fin = 0.000005716 V 14:50:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431032 Vs 14:50:07 Integrated Voltage Measurement... 14:50:26 Voltage Offset Correction: v_off_ini = 0.000005104 V, v_off_fin = -0.000003067 V 14:50:26 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175307804 Vs 15:20:28 Temperature Measurement, Probe Number = 0, T = 20.384000 C 15:20:29 Temperature Measurement, Probe Number = 1, T = 20.056000 C 15:20:30 Temperature Measurement, Probe Number = 2, T = 20.031000 C 15:20:31 Temperature Measurement, Probe Number = 3, T = 20.007000 C 15:20:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:20:31 Integrated Voltage Measurement... 15:20:50 Voltage Offset Correction: v_off_ini = 0.000003856 V, v_off_fin = 0.000006120 V 15:20:50 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175526235 Vs 15:20:50 Integrated Voltage Measurement... 15:21:10 Voltage Offset Correction: v_off_ini = 0.000005540 V, v_off_fin = -0.000001457 V 15:21:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305109 Vs 15:21:12 Temperature Measurement, Probe Number = 0, T = 20.387000 C 15:21:13 Temperature Measurement, Probe Number = 1, T = 20.059000 C 15:21:14 Temperature Measurement, Probe Number = 2, T = 20.029000 C 15:21:14 Temperature Measurement, Probe Number = 3, T = 20.010000 C 15:21:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:21:15 Integrated Voltage Measurement... 15:21:34 Voltage Offset Correction: v_off_ini = 0.000001363 V, v_off_fin = 0.000005547 V 15:21:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428589 Vs 15:21:34 Integrated Voltage Measurement... 15:21:53 Voltage Offset Correction: v_off_ini = 0.000005445 V, v_off_fin = -0.000001786 V 15:21:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301360 Vs 15:21:56 Temperature Measurement, Probe Number = 0, T = 20.397000 C 15:21:57 Temperature Measurement, Probe Number = 1, T = 20.060000 C 15:21:58 Temperature Measurement, Probe Number = 2, T = 20.032000 C 15:21:58 Temperature Measurement, Probe Number = 3, T = 20.010000 C 15:21:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:21:59 Integrated Voltage Measurement... 15:22:17 Voltage Offset Correction: v_off_ini = 0.000001487 V, v_off_fin = 0.000005954 V 15:22:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432547 Vs 15:22:18 Integrated Voltage Measurement... 15:22:37 Voltage Offset Correction: v_off_ini = 0.000005177 V, v_off_fin = -0.000001722 V 15:22:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311182 Vs 15:22:40 Temperature Measurement, Probe Number = 0, T = 20.379000 C 15:22:41 Temperature Measurement, Probe Number = 1, T = 20.062000 C 15:22:41 Temperature Measurement, Probe Number = 2, T = 20.035000 C 15:22:42 Temperature Measurement, Probe Number = 3, T = 20.011000 C 15:22:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:22:42 Integrated Voltage Measurement... 15:23:02 Voltage Offset Correction: v_off_ini = 0.000001036 V, v_off_fin = 0.000005438 V 15:23:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419268 Vs 15:23:02 Integrated Voltage Measurement... 15:23:21 Voltage Offset Correction: v_off_ini = 0.000004649 V, v_off_fin = -0.000002869 V 15:23:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317953 Vs 15:23:24 Temperature Measurement, Probe Number = 0, T = 20.358000 C 15:23:25 Temperature Measurement, Probe Number = 1, T = 20.061000 C 15:23:25 Temperature Measurement, Probe Number = 2, T = 20.032000 C 15:23:26 Temperature Measurement, Probe Number = 3, T = 20.011000 C 15:23:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:23:26 Integrated Voltage Measurement... 15:23:46 Voltage Offset Correction: v_off_ini = 0.000001091 V, v_off_fin = 0.000005367 V 15:23:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428705 Vs 15:23:46 Integrated Voltage Measurement... 15:24:05 Voltage Offset Correction: v_off_ini = 0.000004508 V, v_off_fin = -0.000002121 V 15:24:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317034 Vs 15:24:08 Temperature Measurement, Probe Number = 0, T = 20.370000 C 15:24:09 Temperature Measurement, Probe Number = 1, T = 20.062000 C 15:24:10 Temperature Measurement, Probe Number = 2, T = 20.037000 C 15:24:10 Temperature Measurement, Probe Number = 3, T = 20.014000 C 15:24:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:24:10 Integrated Voltage Measurement... 15:24:30 Voltage Offset Correction: v_off_ini = 0.000001188 V, v_off_fin = 0.000005913 V 15:24:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426891 Vs 15:24:30 Integrated Voltage Measurement... 15:24:49 Voltage Offset Correction: v_off_ini = 0.000005505 V, v_off_fin = -0.000002297 V 15:24:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317117 Vs 15:24:52 Temperature Measurement, Probe Number = 0, T = 20.349000 C 15:24:53 Temperature Measurement, Probe Number = 1, T = 20.062000 C 15:24:54 Temperature Measurement, Probe Number = 2, T = 20.035000 C 15:24:54 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:24:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:24:54 Integrated Voltage Measurement... 15:25:14 Voltage Offset Correction: v_off_ini = 0.000000389 V, v_off_fin = 0.000005547 V 15:25:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430886 Vs 15:25:14 Integrated Voltage Measurement... 15:25:34 Voltage Offset Correction: v_off_ini = 0.000004354 V, v_off_fin = -0.000002794 V 15:25:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322937 Vs 15:25:36 Temperature Measurement, Probe Number = 0, T = 20.356000 C 15:25:37 Temperature Measurement, Probe Number = 1, T = 20.061000 C 15:25:38 Temperature Measurement, Probe Number = 2, T = 20.034000 C 15:25:38 Temperature Measurement, Probe Number = 3, T = 20.010000 C 15:25:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:25:39 Integrated Voltage Measurement... 15:25:58 Voltage Offset Correction: v_off_ini = 0.000000830 V, v_off_fin = 0.000005784 V 15:25:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425083 Vs 15:25:58 Integrated Voltage Measurement... 15:26:17 Voltage Offset Correction: v_off_ini = 0.000004664 V, v_off_fin = -0.000002475 V 15:26:17 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314190 Vs 15:26:20 Temperature Measurement, Probe Number = 0, T = 20.307000 C 15:26:21 Temperature Measurement, Probe Number = 1, T = 20.058000 C 15:26:21 Temperature Measurement, Probe Number = 2, T = 20.033000 C 15:26:22 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:26:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:26:22 Integrated Voltage Measurement... 15:26:41 Voltage Offset Correction: v_off_ini = 0.000001688 V, v_off_fin = 0.000005706 V 15:26:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428253 Vs 15:26:41 Integrated Voltage Measurement... 15:27:01 Voltage Offset Correction: v_off_ini = 0.000005009 V, v_off_fin = -0.000002715 V 15:27:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312516 Vs 15:27:03 Temperature Measurement, Probe Number = 0, T = 20.319000 C 15:27:04 Temperature Measurement, Probe Number = 1, T = 20.058000 C 15:27:05 Temperature Measurement, Probe Number = 2, T = 20.033000 C 15:27:05 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:27:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:27:05 Integrated Voltage Measurement... 15:27:25 Voltage Offset Correction: v_off_ini = 0.000001262 V, v_off_fin = 0.000005991 V 15:27:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424359 Vs 15:27:25 Integrated Voltage Measurement... 15:27:44 Voltage Offset Correction: v_off_ini = 0.000004709 V, v_off_fin = -0.000002686 V 15:27:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311807 Vs 15:57:47 Temperature Measurement, Probe Number = 0, T = 20.158000 C 15:57:48 Temperature Measurement, Probe Number = 1, T = 20.053000 C 15:57:48 Temperature Measurement, Probe Number = 2, T = 20.021000 C 15:57:49 Temperature Measurement, Probe Number = 3, T = 20.003000 C 15:57:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 15:57:49 Integrated Voltage Measurement... 15:58:09 Voltage Offset Correction: v_off_ini = 0.000003829 V, v_off_fin = 0.000005838 V 15:58:09 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175527224 Vs 15:58:09 Integrated Voltage Measurement... 15:58:28 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000001641 V 15:58:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311819 Vs 15:58:31 Temperature Measurement, Probe Number = 0, T = 20.221000 C 15:58:32 Temperature Measurement, Probe Number = 1, T = 20.054000 C 15:58:33 Temperature Measurement, Probe Number = 2, T = 20.019000 C 15:58:33 Temperature Measurement, Probe Number = 3, T = 20.004000 C 15:58:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 15:58:33 Integrated Voltage Measurement... 15:58:53 Voltage Offset Correction: v_off_ini = 0.000001399 V, v_off_fin = 0.000005837 V 15:58:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429654 Vs 15:58:53 Integrated Voltage Measurement... 15:59:12 Voltage Offset Correction: v_off_ini = 0.000005154 V, v_off_fin = -0.000001834 V 15:59:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303998 Vs 15:59:15 Temperature Measurement, Probe Number = 0, T = 20.240000 C 15:59:16 Temperature Measurement, Probe Number = 1, T = 20.054000 C 15:59:16 Temperature Measurement, Probe Number = 2, T = 20.023000 C 15:59:17 Temperature Measurement, Probe Number = 3, T = 20.006000 C 15:59:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 15:59:17 Integrated Voltage Measurement... 15:59:37 Voltage Offset Correction: v_off_ini = 0.000001231 V, v_off_fin = 0.000006097 V 15:59:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435220 Vs 15:59:37 Integrated Voltage Measurement... 15:59:56 Voltage Offset Correction: v_off_ini = 0.000005121 V, v_off_fin = -0.000001074 V 15:59:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302369 Vs 15:59:59 Temperature Measurement, Probe Number = 0, T = 20.219000 C 16:00:00 Temperature Measurement, Probe Number = 1, T = 20.055000 C 16:00:00 Temperature Measurement, Probe Number = 2, T = 20.026000 C 16:00:01 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:00:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:00:01 Integrated Voltage Measurement... 16:00:20 Voltage Offset Correction: v_off_ini = 0.000001761 V, v_off_fin = 0.000006648 V 16:00:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434795 Vs 16:00:20 Integrated Voltage Measurement... 16:00:39 Voltage Offset Correction: v_off_ini = 0.000005548 V, v_off_fin = -0.000002007 V 16:00:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315892 Vs 16:00:42 Temperature Measurement, Probe Number = 0, T = 20.221000 C 16:00:43 Temperature Measurement, Probe Number = 1, T = 20.055000 C 16:00:44 Temperature Measurement, Probe Number = 2, T = 20.029000 C 16:00:44 Temperature Measurement, Probe Number = 3, T = 20.011000 C 16:00:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:00:45 Integrated Voltage Measurement... 16:01:04 Voltage Offset Correction: v_off_ini = 0.000001899 V, v_off_fin = 0.000005841 V 16:01:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439425 Vs 16:01:04 Integrated Voltage Measurement... 16:01:24 Voltage Offset Correction: v_off_ini = 0.000005395 V, v_off_fin = -0.000001382 V 16:01:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307271 Vs 16:01:27 Temperature Measurement, Probe Number = 0, T = 20.215000 C 16:01:27 Temperature Measurement, Probe Number = 1, T = 20.057000 C 16:01:28 Temperature Measurement, Probe Number = 2, T = 20.030000 C 16:01:29 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:01:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:01:29 Integrated Voltage Measurement... 16:01:48 Voltage Offset Correction: v_off_ini = 0.000001753 V, v_off_fin = 0.000006767 V 16:01:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442502 Vs 16:01:48 Integrated Voltage Measurement... 16:02:08 Voltage Offset Correction: v_off_ini = 0.000005812 V, v_off_fin = -0.000001279 V 16:02:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309376 Vs 16:02:11 Temperature Measurement, Probe Number = 0, T = 20.217000 C 16:02:11 Temperature Measurement, Probe Number = 1, T = 20.059000 C 16:02:12 Temperature Measurement, Probe Number = 2, T = 20.027000 C 16:02:13 Temperature Measurement, Probe Number = 3, T = 20.008000 C 16:02:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:02:13 Integrated Voltage Measurement... 16:02:32 Voltage Offset Correction: v_off_ini = 0.000002086 V, v_off_fin = 0.000005956 V 16:02:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438235 Vs 16:02:32 Integrated Voltage Measurement... 16:02:52 Voltage Offset Correction: v_off_ini = 0.000005936 V, v_off_fin = -0.000001180 V 16:02:52 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175308356 Vs 16:02:55 Temperature Measurement, Probe Number = 0, T = 20.236000 C 16:02:56 Temperature Measurement, Probe Number = 1, T = 20.058000 C 16:02:56 Temperature Measurement, Probe Number = 2, T = 20.026000 C 16:02:57 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:02:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:02:57 Integrated Voltage Measurement... 16:03:17 Voltage Offset Correction: v_off_ini = 0.000001223 V, v_off_fin = 0.000006157 V 16:03:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429864 Vs 16:03:17 Integrated Voltage Measurement... 16:03:36 Voltage Offset Correction: v_off_ini = 0.000005207 V, v_off_fin = -0.000001792 V 16:03:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175317568 Vs 16:03:39 Temperature Measurement, Probe Number = 0, T = 20.255000 C 16:03:40 Temperature Measurement, Probe Number = 1, T = 20.059000 C 16:03:40 Temperature Measurement, Probe Number = 2, T = 20.030000 C 16:03:41 Temperature Measurement, Probe Number = 3, T = 20.010000 C 16:03:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:03:41 Integrated Voltage Measurement... 16:04:00 Voltage Offset Correction: v_off_ini = 0.000001354 V, v_off_fin = 0.000006290 V 16:04:00 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175446953 Vs 16:04:01 Integrated Voltage Measurement... 16:04:20 Voltage Offset Correction: v_off_ini = 0.000005464 V, v_off_fin = -0.000001935 V 16:04:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319570 Vs 16:04:23 Temperature Measurement, Probe Number = 0, T = 20.327000 C 16:04:24 Temperature Measurement, Probe Number = 1, T = 20.062000 C 16:04:24 Temperature Measurement, Probe Number = 2, T = 20.033000 C 16:04:25 Temperature Measurement, Probe Number = 3, T = 20.013000 C 16:04:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:04:25 Integrated Voltage Measurement... 16:04:44 Voltage Offset Correction: v_off_ini = 0.000001880 V, v_off_fin = 0.000006159 V 16:04:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175433921 Vs 16:04:45 Integrated Voltage Measurement... 16:05:04 Voltage Offset Correction: v_off_ini = 0.000005554 V, v_off_fin = -0.000001809 V 16:05:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315862 Vs 16:35:07 Temperature Measurement, Probe Number = 0, T = 20.280000 C 16:35:08 Temperature Measurement, Probe Number = 1, T = 20.057000 C 16:35:08 Temperature Measurement, Probe Number = 2, T = 20.027000 C 16:35:09 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:35:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:35:09 Integrated Voltage Measurement... 16:35:28 Voltage Offset Correction: v_off_ini = 0.000004044 V, v_off_fin = 0.000005905 V 16:35:28 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175528085 Vs 16:35:29 Integrated Voltage Measurement... 16:35:48 Voltage Offset Correction: v_off_ini = 0.000005168 V, v_off_fin = -0.000002043 V 16:35:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300640 Vs 16:35:51 Temperature Measurement, Probe Number = 0, T = 20.292000 C 16:35:52 Temperature Measurement, Probe Number = 1, T = 20.059000 C 16:35:52 Temperature Measurement, Probe Number = 2, T = 20.028000 C 16:35:53 Temperature Measurement, Probe Number = 3, T = 20.009000 C 16:35:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:35:53 Integrated Voltage Measurement... 16:36:12 Voltage Offset Correction: v_off_ini = 0.000000654 V, v_off_fin = 0.000005948 V 16:36:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418581 Vs 16:36:13 Integrated Voltage Measurement... 16:36:32 Voltage Offset Correction: v_off_ini = 0.000005140 V, v_off_fin = -0.000002326 V 16:36:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309049 Vs 16:36:35 Temperature Measurement, Probe Number = 0, T = 20.299000 C 16:36:35 Temperature Measurement, Probe Number = 1, T = 20.058000 C 16:36:36 Temperature Measurement, Probe Number = 2, T = 20.032000 C 16:36:37 Temperature Measurement, Probe Number = 3, T = 20.010000 C 16:36:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:36:37 Integrated Voltage Measurement... 16:36:56 Voltage Offset Correction: v_off_ini = 0.000001263 V, v_off_fin = 0.000006284 V 16:36:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431064 Vs 16:36:57 Integrated Voltage Measurement... 16:37:16 Voltage Offset Correction: v_off_ini = 0.000005759 V, v_off_fin = -0.000001505 V 16:37:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308402 Vs 16:37:19 Temperature Measurement, Probe Number = 0, T = 20.320000 C 16:37:20 Temperature Measurement, Probe Number = 1, T = 20.060000 C 16:37:20 Temperature Measurement, Probe Number = 2, T = 20.032000 C 16:37:21 Temperature Measurement, Probe Number = 3, T = 20.011000 C 16:37:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:37:21 Integrated Voltage Measurement... 16:37:40 Voltage Offset Correction: v_off_ini = 0.000001338 V, v_off_fin = 0.000006376 V 16:37:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430837 Vs 16:37:41 Integrated Voltage Measurement... 16:38:00 Voltage Offset Correction: v_off_ini = 0.000005735 V, v_off_fin = -0.000001321 V 16:38:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306520 Vs 16:38:03 Temperature Measurement, Probe Number = 0, T = 20.318000 C 16:38:04 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:38:04 Temperature Measurement, Probe Number = 2, T = 20.032000 C 16:38:05 Temperature Measurement, Probe Number = 3, T = 20.012000 C 16:38:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:38:05 Integrated Voltage Measurement... 16:38:24 Voltage Offset Correction: v_off_ini = 0.000001783 V, v_off_fin = 0.000006856 V 16:38:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436067 Vs 16:38:25 Integrated Voltage Measurement... 16:38:44 Voltage Offset Correction: v_off_ini = 0.000006478 V, v_off_fin = -0.000001155 V 16:38:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298721 Vs 16:38:47 Temperature Measurement, Probe Number = 0, T = 20.384000 C 16:38:48 Temperature Measurement, Probe Number = 1, T = 20.062000 C 16:38:48 Temperature Measurement, Probe Number = 2, T = 20.032000 C 16:38:49 Temperature Measurement, Probe Number = 3, T = 20.014000 C 16:38:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:38:49 Integrated Voltage Measurement... 16:39:09 Voltage Offset Correction: v_off_ini = 0.000002243 V, v_off_fin = 0.000006697 V 16:39:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441621 Vs 16:39:10 Integrated Voltage Measurement... 16:39:29 Voltage Offset Correction: v_off_ini = 0.000005881 V, v_off_fin = -0.000001783 V 16:39:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292054 Vs 16:39:31 Temperature Measurement, Probe Number = 0, T = 20.400000 C 16:39:32 Temperature Measurement, Probe Number = 1, T = 20.066000 C 16:39:33 Temperature Measurement, Probe Number = 2, T = 20.037000 C 16:39:33 Temperature Measurement, Probe Number = 3, T = 20.014000 C 16:39:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:39:34 Integrated Voltage Measurement... 16:39:53 Voltage Offset Correction: v_off_ini = 0.000002245 V, v_off_fin = 0.000006689 V 16:39:53 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175435549 Vs 16:39:53 Integrated Voltage Measurement... 16:40:13 Voltage Offset Correction: v_off_ini = 0.000005525 V, v_off_fin = -0.000001233 V 16:40:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300351 Vs 16:40:16 Temperature Measurement, Probe Number = 0, T = 20.411000 C 16:40:16 Temperature Measurement, Probe Number = 1, T = 20.062000 C 16:40:17 Temperature Measurement, Probe Number = 2, T = 20.040000 C 16:40:18 Temperature Measurement, Probe Number = 3, T = 20.012000 C 16:40:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:40:18 Integrated Voltage Measurement... 16:40:37 Voltage Offset Correction: v_off_ini = 0.000001438 V, v_off_fin = 0.000006208 V 16:40:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422795 Vs 16:40:37 Integrated Voltage Measurement... 16:40:56 Voltage Offset Correction: v_off_ini = 0.000005929 V, v_off_fin = -0.000001780 V 16:40:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299635 Vs 16:40:59 Temperature Measurement, Probe Number = 0, T = 20.373000 C 16:41:00 Temperature Measurement, Probe Number = 1, T = 20.064000 C 16:41:01 Temperature Measurement, Probe Number = 2, T = 20.040000 C 16:41:01 Temperature Measurement, Probe Number = 3, T = 20.016000 C 16:41:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 16:41:01 Integrated Voltage Measurement... 16:41:21 Voltage Offset Correction: v_off_ini = 0.000002304 V, v_off_fin = 0.000006312 V 16:41:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436097 Vs 16:41:21 Integrated Voltage Measurement... 16:41:40 Voltage Offset Correction: v_off_ini = 0.000005374 V, v_off_fin = -0.000001763 V 16:41:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302091 Vs 16:41:43 Temperature Measurement, Probe Number = 0, T = 20.379000 C 16:41:44 Temperature Measurement, Probe Number = 1, T = 20.065000 C 16:41:45 Temperature Measurement, Probe Number = 2, T = 20.040000 C 16:41:45 Temperature Measurement, Probe Number = 3, T = 20.016000 C 16:41:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 16:41:45 Integrated Voltage Measurement... 16:42:05 Voltage Offset Correction: v_off_ini = 0.000001087 V, v_off_fin = 0.000005835 V 16:42:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425376 Vs 16:42:05 Integrated Voltage Measurement... 16:42:24 Voltage Offset Correction: v_off_ini = 0.000005384 V, v_off_fin = -0.000001749 V 16:42:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306276 Vs 17:12:27 Temperature Measurement, Probe Number = 0, T = 20.337000 C 17:12:28 Temperature Measurement, Probe Number = 1, T = 20.060000 C 17:12:28 Temperature Measurement, Probe Number = 2, T = 20.033000 C 17:12:29 Temperature Measurement, Probe Number = 3, T = 20.013000 C 17:12:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:12:29 Integrated Voltage Measurement... 17:12:48 Voltage Offset Correction: v_off_ini = 0.000004137 V, v_off_fin = 0.000006268 V 17:12:49 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175523842 Vs 17:12:49 Integrated Voltage Measurement... 17:13:08 Voltage Offset Correction: v_off_ini = 0.000005698 V, v_off_fin = -0.000001583 V 17:13:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298718 Vs 17:13:11 Temperature Measurement, Probe Number = 0, T = 20.347000 C 17:13:11 Temperature Measurement, Probe Number = 1, T = 20.060000 C 17:13:12 Temperature Measurement, Probe Number = 2, T = 20.036000 C 17:13:13 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:13:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:13:13 Integrated Voltage Measurement... 17:13:32 Voltage Offset Correction: v_off_ini = 0.000001675 V, v_off_fin = 0.000006315 V 17:13:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431433 Vs 17:13:32 Integrated Voltage Measurement... 17:13:52 Voltage Offset Correction: v_off_ini = 0.000005805 V, v_off_fin = -0.000001811 V 17:13:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300215 Vs 17:13:54 Temperature Measurement, Probe Number = 0, T = 20.312000 C 17:13:55 Temperature Measurement, Probe Number = 1, T = 20.061000 C 17:13:56 Temperature Measurement, Probe Number = 2, T = 20.034000 C 17:13:56 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:13:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:13:57 Integrated Voltage Measurement... 17:14:16 Voltage Offset Correction: v_off_ini = 0.000002161 V, v_off_fin = 0.000006682 V 17:14:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437445 Vs 17:14:16 Integrated Voltage Measurement... 17:14:35 Voltage Offset Correction: v_off_ini = 0.000006298 V, v_off_fin = -0.000001358 V 17:14:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306145 Vs 17:14:38 Temperature Measurement, Probe Number = 0, T = 20.322000 C 17:14:39 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:14:40 Temperature Measurement, Probe Number = 2, T = 20.036000 C 17:14:40 Temperature Measurement, Probe Number = 3, T = 20.013000 C 17:14:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 17:14:41 Integrated Voltage Measurement... 17:15:00 Voltage Offset Correction: v_off_ini = 0.000001914 V, v_off_fin = 0.000006526 V 17:15:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437847 Vs 17:15:00 Integrated Voltage Measurement... 17:15:19 Voltage Offset Correction: v_off_ini = 0.000005908 V, v_off_fin = -0.000001679 V 17:15:19 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175297673 Vs 17:15:22 Temperature Measurement, Probe Number = 0, T = 20.310000 C 17:15:22 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:15:23 Temperature Measurement, Probe Number = 2, T = 20.033000 C 17:15:24 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:15:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:15:24 Integrated Voltage Measurement... 17:15:43 Voltage Offset Correction: v_off_ini = 0.000001426 V, v_off_fin = 0.000005954 V 17:15:43 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175436781 Vs 17:15:43 Integrated Voltage Measurement... 17:16:03 Voltage Offset Correction: v_off_ini = 0.000005229 V, v_off_fin = -0.000001819 V 17:16:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306348 Vs 17:16:06 Temperature Measurement, Probe Number = 0, T = 20.292000 C 17:16:06 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:16:07 Temperature Measurement, Probe Number = 2, T = 20.032000 C 17:16:08 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:16:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:16:08 Integrated Voltage Measurement... 17:16:27 Voltage Offset Correction: v_off_ini = 0.000002330 V, v_off_fin = 0.000006287 V 17:16:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434937 Vs 17:16:27 Integrated Voltage Measurement... 17:16:47 Voltage Offset Correction: v_off_ini = 0.000005036 V, v_off_fin = -0.000002339 V 17:16:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297641 Vs 17:16:50 Temperature Measurement, Probe Number = 0, T = 20.246000 C 17:16:50 Temperature Measurement, Probe Number = 1, T = 20.061000 C 17:16:51 Temperature Measurement, Probe Number = 2, T = 20.033000 C 17:16:52 Temperature Measurement, Probe Number = 3, T = 20.014000 C 17:16:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:16:52 Integrated Voltage Measurement... 17:17:11 Voltage Offset Correction: v_off_ini = 0.000002156 V, v_off_fin = 0.000006591 V 17:17:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428280 Vs 17:17:11 Integrated Voltage Measurement... 17:17:31 Voltage Offset Correction: v_off_ini = 0.000005291 V, v_off_fin = -0.000002167 V 17:17:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310656 Vs 17:17:34 Temperature Measurement, Probe Number = 0, T = 20.265000 C 17:17:34 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:17:35 Temperature Measurement, Probe Number = 2, T = 20.029000 C 17:17:36 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:17:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:17:36 Integrated Voltage Measurement... 17:17:55 Voltage Offset Correction: v_off_ini = 0.000002173 V, v_off_fin = 0.000006789 V 17:17:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440207 Vs 17:17:55 Integrated Voltage Measurement... 17:18:14 Voltage Offset Correction: v_off_ini = 0.000006007 V, v_off_fin = -0.000001318 V 17:18:15 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175301241 Vs 17:18:17 Temperature Measurement, Probe Number = 0, T = 20.268000 C 17:18:18 Temperature Measurement, Probe Number = 1, T = 20.063000 C 17:18:19 Temperature Measurement, Probe Number = 2, T = 20.034000 C 17:18:19 Temperature Measurement, Probe Number = 3, T = 20.015000 C 17:18:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.02 17:18:20 Integrated Voltage Measurement... 17:18:39 Voltage Offset Correction: v_off_ini = 0.000001891 V, v_off_fin = 0.000005752 V 17:18:39 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438038 Vs 17:18:39 Integrated Voltage Measurement... 17:18:58 Voltage Offset Correction: v_off_ini = 0.000005276 V, v_off_fin = -0.000001854 V 17:18:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304707 Vs 17:19:01 Temperature Measurement, Probe Number = 0, T = 20.337000 C 17:19:02 Temperature Measurement, Probe Number = 1, T = 20.066000 C 17:19:02 Temperature Measurement, Probe Number = 2, T = 20.038000 C 17:19:03 Temperature Measurement, Probe Number = 3, T = 20.019000 C 17:19:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 17:19:03 Integrated Voltage Measurement... 17:19:22 Voltage Offset Correction: v_off_ini = 0.000002171 V, v_off_fin = 0.000006146 V 17:19:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429177 Vs 17:19:23 Integrated Voltage Measurement... 17:19:42 Voltage Offset Correction: v_off_ini = 0.000005443 V, v_off_fin = -0.000001924 V 17:19:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310726 Vs 17:49:45 Temperature Measurement, Probe Number = 0, T = 20.154000 C 17:49:46 Temperature Measurement, Probe Number = 1, T = 20.058000 C 17:49:47 Temperature Measurement, Probe Number = 2, T = 20.022000 C 17:49:47 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:49:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:49:47 Integrated Voltage Measurement... 17:50:08 Voltage Offset Correction: v_off_ini = 0.000003681 V, v_off_fin = 0.000005800 V 17:50:08 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175519871 Vs 17:50:08 Integrated Voltage Measurement... 17:50:28 Voltage Offset Correction: v_off_ini = 0.000005057 V, v_off_fin = -0.000001978 V 17:50:28 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175320985 Vs 17:50:31 Temperature Measurement, Probe Number = 0, T = 20.191000 C 17:50:32 Temperature Measurement, Probe Number = 1, T = 20.057000 C 17:50:32 Temperature Measurement, Probe Number = 2, T = 20.024000 C 17:50:33 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:50:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:50:33 Integrated Voltage Measurement... 17:50:52 Voltage Offset Correction: v_off_ini = 0.000001842 V, v_off_fin = 0.000006135 V 17:50:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431689 Vs 17:50:53 Integrated Voltage Measurement... 17:51:12 Voltage Offset Correction: v_off_ini = 0.000005455 V, v_off_fin = -0.000002051 V 17:51:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310508 Vs 17:51:15 Temperature Measurement, Probe Number = 0, T = 20.217000 C 17:51:15 Temperature Measurement, Probe Number = 1, T = 20.058000 C 17:51:16 Temperature Measurement, Probe Number = 2, T = 20.025000 C 17:51:17 Temperature Measurement, Probe Number = 3, T = 20.015000 C 17:51:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.02 17:51:17 Integrated Voltage Measurement... 17:51:36 Voltage Offset Correction: v_off_ini = 0.000001243 V, v_off_fin = 0.000006257 V 17:51:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436056 Vs 17:51:36 Integrated Voltage Measurement... 17:51:56 Voltage Offset Correction: v_off_ini = 0.000005396 V, v_off_fin = -0.000002297 V 17:51:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307540 Vs 17:51:58 Temperature Measurement, Probe Number = 0, T = 20.215000 C 17:51:59 Temperature Measurement, Probe Number = 1, T = 20.062000 C 17:52:00 Temperature Measurement, Probe Number = 2, T = 20.030000 C 17:52:00 Temperature Measurement, Probe Number = 3, T = 20.015000 C 17:52:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.02 17:52:01 Integrated Voltage Measurement... 17:52:20 Voltage Offset Correction: v_off_ini = 0.000001871 V, v_off_fin = 0.000006413 V 17:52:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175444086 Vs 17:52:21 Integrated Voltage Measurement... 17:52:40 Voltage Offset Correction: v_off_ini = 0.000005583 V, v_off_fin = -0.000002334 V 17:52:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316460 Vs 17:52:43 Temperature Measurement, Probe Number = 0, T = 20.237000 C 17:52:44 Temperature Measurement, Probe Number = 1, T = 20.064000 C 17:52:44 Temperature Measurement, Probe Number = 2, T = 20.034000 C 17:52:45 Temperature Measurement, Probe Number = 3, T = 20.016000 C 17:52:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.02 17:52:45 Integrated Voltage Measurement... 17:53:04 Voltage Offset Correction: v_off_ini = 0.000001735 V, v_off_fin = 0.000006316 V 17:53:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432893 Vs 17:53:04 Integrated Voltage Measurement... 17:53:23 Voltage Offset Correction: v_off_ini = 0.000004793 V, v_off_fin = -0.000002562 V 17:53:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309382 Vs 17:53:26 Temperature Measurement, Probe Number = 0, T = 20.223000 C 17:53:27 Temperature Measurement, Probe Number = 1, T = 20.061000 C 17:53:28 Temperature Measurement, Probe Number = 2, T = 20.031000 C 17:53:28 Temperature Measurement, Probe Number = 3, T = 20.013000 C 17:53:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 17:53:28 Integrated Voltage Measurement... 17:53:47 Voltage Offset Correction: v_off_ini = 0.000001718 V, v_off_fin = 0.000006274 V 17:53:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439129 Vs 17:53:48 Integrated Voltage Measurement... 17:54:07 Voltage Offset Correction: v_off_ini = 0.000005325 V, v_off_fin = -0.000002211 V 17:54:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318748 Vs 17:54:10 Temperature Measurement, Probe Number = 0, T = 20.175000 C 17:54:11 Temperature Measurement, Probe Number = 1, T = 20.060000 C 17:54:11 Temperature Measurement, Probe Number = 2, T = 20.024000 C 17:54:12 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:54:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:54:12 Integrated Voltage Measurement... 17:54:31 Voltage Offset Correction: v_off_ini = 0.000000940 V, v_off_fin = 0.000005949 V 17:54:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438473 Vs 17:54:32 Integrated Voltage Measurement... 17:54:51 Voltage Offset Correction: v_off_ini = 0.000005151 V, v_off_fin = -0.000002519 V 17:54:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316726 Vs 17:54:54 Temperature Measurement, Probe Number = 0, T = 20.228000 C 17:54:55 Temperature Measurement, Probe Number = 1, T = 20.060000 C 17:54:55 Temperature Measurement, Probe Number = 2, T = 20.023000 C 17:54:56 Temperature Measurement, Probe Number = 3, T = 20.010000 C 17:54:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:54:56 Integrated Voltage Measurement... 17:55:15 Voltage Offset Correction: v_off_ini = 0.000001341 V, v_off_fin = 0.000006389 V 17:55:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436729 Vs 17:55:16 Integrated Voltage Measurement... 17:55:35 Voltage Offset Correction: v_off_ini = 0.000005363 V, v_off_fin = -0.000001949 V 17:55:35 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175303523 Vs 17:55:37 Temperature Measurement, Probe Number = 0, T = 20.129000 C 17:55:38 Temperature Measurement, Probe Number = 1, T = 20.059000 C 17:55:39 Temperature Measurement, Probe Number = 2, T = 20.023000 C 17:55:39 Temperature Measurement, Probe Number = 3, T = 20.012000 C 17:55:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:55:40 Integrated Voltage Measurement... 17:55:59 Voltage Offset Correction: v_off_ini = 0.000001184 V, v_off_fin = 0.000006410 V 17:55:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443854 Vs 17:55:59 Integrated Voltage Measurement... 17:56:18 Voltage Offset Correction: v_off_ini = 0.000005912 V, v_off_fin = -0.000002103 V 17:56:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311739 Vs 17:56:21 Temperature Measurement, Probe Number = 0, T = 20.095000 C 17:56:22 Temperature Measurement, Probe Number = 1, T = 20.058000 C 17:56:23 Temperature Measurement, Probe Number = 2, T = 20.021000 C 17:56:23 Temperature Measurement, Probe Number = 3, T = 20.009000 C 17:56:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 17:56:24 Integrated Voltage Measurement... 17:56:43 Voltage Offset Correction: v_off_ini = 0.000001142 V, v_off_fin = 0.000005978 V 17:56:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437084 Vs 17:56:44 Integrated Voltage Measurement... 17:57:03 Voltage Offset Correction: v_off_ini = 0.000004964 V, v_off_fin = -0.000001570 V 17:57:03 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304617 Vs 18:27:06 Temperature Measurement, Probe Number = 0, T = 20.161000 C 18:27:07 Temperature Measurement, Probe Number = 1, T = 20.053000 C 18:27:08 Temperature Measurement, Probe Number = 2, T = 20.017000 C 18:27:08 Temperature Measurement, Probe Number = 3, T = 20.004000 C 18:27:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 18:27:08 Integrated Voltage Measurement... 18:27:28 Voltage Offset Correction: v_off_ini = 0.000003888 V, v_off_fin = 0.000006121 V 18:27:28 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175510132 Vs 18:27:28 Integrated Voltage Measurement... 18:27:47 Voltage Offset Correction: v_off_ini = 0.000005549 V, v_off_fin = -0.000001523 V 18:27:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322324 Vs 18:27:50 Temperature Measurement, Probe Number = 0, T = 20.212000 C 18:27:51 Temperature Measurement, Probe Number = 1, T = 20.055000 C 18:27:51 Temperature Measurement, Probe Number = 2, T = 20.023000 C 18:27:52 Temperature Measurement, Probe Number = 3, T = 20.010000 C 18:27:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:27:52 Integrated Voltage Measurement... 18:28:12 Voltage Offset Correction: v_off_ini = 0.000001486 V, v_off_fin = 0.000006488 V 18:28:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437182 Vs 18:28:12 Integrated Voltage Measurement... 18:28:31 Voltage Offset Correction: v_off_ini = 0.000005768 V, v_off_fin = -0.000000980 V 18:28:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317354 Vs 18:28:34 Temperature Measurement, Probe Number = 0, T = 20.229000 C 18:28:35 Temperature Measurement, Probe Number = 1, T = 20.052000 C 18:28:36 Temperature Measurement, Probe Number = 2, T = 20.021000 C 18:28:36 Temperature Measurement, Probe Number = 3, T = 20.007000 C 18:28:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:28:37 Integrated Voltage Measurement... 18:28:56 Voltage Offset Correction: v_off_ini = 0.000001625 V, v_off_fin = 0.000005781 V 18:28:56 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436317 Vs 18:28:57 Integrated Voltage Measurement... 18:29:16 Voltage Offset Correction: v_off_ini = 0.000005242 V, v_off_fin = -0.000001977 V 18:29:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310094 Vs 18:29:19 Temperature Measurement, Probe Number = 0, T = 20.236000 C 18:29:19 Temperature Measurement, Probe Number = 1, T = 20.055000 C 18:29:20 Temperature Measurement, Probe Number = 2, T = 20.026000 C 18:29:21 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:29:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 18:29:21 Integrated Voltage Measurement... 18:29:40 Voltage Offset Correction: v_off_ini = 0.000001350 V, v_off_fin = 0.000005502 V 18:29:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437289 Vs 18:29:40 Integrated Voltage Measurement... 18:30:00 Voltage Offset Correction: v_off_ini = 0.000005049 V, v_off_fin = -0.000000874 V 18:30:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314126 Vs 18:30:03 Temperature Measurement, Probe Number = 0, T = 20.223000 C 18:30:03 Temperature Measurement, Probe Number = 1, T = 20.056000 C 18:30:04 Temperature Measurement, Probe Number = 2, T = 20.023000 C 18:30:05 Temperature Measurement, Probe Number = 3, T = 20.013000 C 18:30:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:30:05 Integrated Voltage Measurement... 18:30:24 Voltage Offset Correction: v_off_ini = 0.000001558 V, v_off_fin = 0.000005731 V 18:30:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431974 Vs 18:30:24 Integrated Voltage Measurement... 18:30:44 Voltage Offset Correction: v_off_ini = 0.000005010 V, v_off_fin = -0.000001786 V 18:30:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316819 Vs 18:30:46 Temperature Measurement, Probe Number = 0, T = 20.199000 C 18:30:47 Temperature Measurement, Probe Number = 1, T = 20.052000 C 18:30:48 Temperature Measurement, Probe Number = 2, T = 20.021000 C 18:30:48 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:30:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:30:49 Integrated Voltage Measurement... 18:31:08 Voltage Offset Correction: v_off_ini = 0.000001463 V, v_off_fin = 0.000005700 V 18:31:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437726 Vs 18:31:08 Integrated Voltage Measurement... 18:31:28 Voltage Offset Correction: v_off_ini = 0.000005537 V, v_off_fin = -0.000002022 V 18:31:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316839 Vs 18:31:30 Temperature Measurement, Probe Number = 0, T = 20.203000 C 18:31:31 Temperature Measurement, Probe Number = 1, T = 20.051000 C 18:31:32 Temperature Measurement, Probe Number = 2, T = 20.020000 C 18:31:32 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:31:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:31:33 Integrated Voltage Measurement... 18:31:52 Voltage Offset Correction: v_off_ini = 0.000001186 V, v_off_fin = 0.000005603 V 18:31:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445729 Vs 18:31:52 Integrated Voltage Measurement... 18:32:11 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000002618 V 18:32:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315059 Vs 18:32:14 Temperature Measurement, Probe Number = 0, T = 20.257000 C 18:32:15 Temperature Measurement, Probe Number = 1, T = 20.052000 C 18:32:15 Temperature Measurement, Probe Number = 2, T = 20.020000 C 18:32:16 Temperature Measurement, Probe Number = 3, T = 20.006000 C 18:32:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:32:16 Integrated Voltage Measurement... 18:32:36 Voltage Offset Correction: v_off_ini = 0.000002097 V, v_off_fin = 0.000005433 V 18:32:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442298 Vs 18:32:36 Integrated Voltage Measurement... 18:32:55 Voltage Offset Correction: v_off_ini = 0.000004916 V, v_off_fin = -0.000001705 V 18:32:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315864 Vs 18:32:58 Temperature Measurement, Probe Number = 0, T = 20.307000 C 18:32:59 Temperature Measurement, Probe Number = 1, T = 20.055000 C 18:32:59 Temperature Measurement, Probe Number = 2, T = 20.021000 C 18:33:00 Temperature Measurement, Probe Number = 3, T = 20.008000 C 18:33:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.01 18:33:00 Integrated Voltage Measurement... 18:33:19 Voltage Offset Correction: v_off_ini = 0.000001062 V, v_off_fin = 0.000005700 V 18:33:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442617 Vs 18:33:19 Integrated Voltage Measurement... 18:33:38 Voltage Offset Correction: v_off_ini = 0.000005078 V, v_off_fin = -0.000001878 V 18:33:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314190 Vs 18:33:41 Temperature Measurement, Probe Number = 0, T = 20.328000 C 18:33:42 Temperature Measurement, Probe Number = 1, T = 20.058000 C 18:33:42 Temperature Measurement, Probe Number = 2, T = 20.026000 C 18:33:43 Temperature Measurement, Probe Number = 3, T = 20.013000 C 18:33:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 18:33:43 Integrated Voltage Measurement... 18:34:03 Voltage Offset Correction: v_off_ini = 0.000001642 V, v_off_fin = 0.000005558 V 18:34:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175447327 Vs 18:34:03 Integrated Voltage Measurement... 18:34:23 Voltage Offset Correction: v_off_ini = 0.000004851 V, v_off_fin = -0.000002574 V 18:34:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323949 Vs 19:04:26 Temperature Measurement, Probe Number = 0, T = 20.208000 C 19:04:27 Temperature Measurement, Probe Number = 1, T = 20.046000 C 19:04:27 Temperature Measurement, Probe Number = 2, T = 20.008000 C 19:04:28 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:04:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:04:28 Integrated Voltage Measurement... 19:04:48 Voltage Offset Correction: v_off_ini = 0.000003367 V, v_off_fin = 0.000006068 V 19:04:48 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175529317 Vs 19:04:48 Integrated Voltage Measurement... 19:05:07 Voltage Offset Correction: v_off_ini = 0.000005357 V, v_off_fin = -0.000001888 V 19:05:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314961 Vs 19:05:10 Temperature Measurement, Probe Number = 0, T = 20.166000 C 19:05:11 Temperature Measurement, Probe Number = 1, T = 20.047000 C 19:05:11 Temperature Measurement, Probe Number = 2, T = 20.008000 C 19:05:12 Temperature Measurement, Probe Number = 3, T = 19.992000 C 19:05:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 19:05:12 Integrated Voltage Measurement... 19:05:31 Voltage Offset Correction: v_off_ini = 0.000001371 V, v_off_fin = 0.000006274 V 19:05:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442430 Vs 19:05:31 Integrated Voltage Measurement... 19:05:50 Voltage Offset Correction: v_off_ini = 0.000005359 V, v_off_fin = -0.000002401 V 19:05:50 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175315192 Vs 19:05:53 Temperature Measurement, Probe Number = 0, T = 20.139000 C 19:05:54 Temperature Measurement, Probe Number = 1, T = 20.049000 C 19:05:54 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:05:55 Temperature Measurement, Probe Number = 3, T = 19.994000 C 19:05:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 19:05:55 Integrated Voltage Measurement... 19:06:14 Voltage Offset Correction: v_off_ini = 0.000001131 V, v_off_fin = 0.000006171 V 19:06:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175444231 Vs 19:06:14 Integrated Voltage Measurement... 19:06:34 Voltage Offset Correction: v_off_ini = 0.000005675 V, v_off_fin = -0.000002032 V 19:06:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323083 Vs 19:06:37 Temperature Measurement, Probe Number = 0, T = 20.111000 C 19:06:38 Temperature Measurement, Probe Number = 1, T = 20.047000 C 19:06:38 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:06:39 Temperature Measurement, Probe Number = 3, T = 19.996000 C 19:06:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:06:39 Integrated Voltage Measurement... 19:06:58 Voltage Offset Correction: v_off_ini = 0.000002624 V, v_off_fin = 0.000006535 V 19:06:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443997 Vs 19:06:59 Integrated Voltage Measurement... 19:07:18 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000002034 V 19:07:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315695 Vs 19:07:21 Temperature Measurement, Probe Number = 0, T = 20.135000 C 19:07:22 Temperature Measurement, Probe Number = 1, T = 20.044000 C 19:07:22 Temperature Measurement, Probe Number = 2, T = 20.013000 C 19:07:23 Temperature Measurement, Probe Number = 3, T = 20.000000 C 19:07:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:07:23 Integrated Voltage Measurement... 19:07:42 Voltage Offset Correction: v_off_ini = 0.000001967 V, v_off_fin = 0.000005481 V 19:07:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439351 Vs 19:07:43 Integrated Voltage Measurement... 19:08:02 Voltage Offset Correction: v_off_ini = 0.000005429 V, v_off_fin = -0.000003175 V 19:08:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319487 Vs 19:08:04 Temperature Measurement, Probe Number = 0, T = 20.148000 C 19:08:05 Temperature Measurement, Probe Number = 1, T = 20.046000 C 19:08:06 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:08:06 Temperature Measurement, Probe Number = 3, T = 20.000000 C 19:08:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:08:07 Integrated Voltage Measurement... 19:08:26 Voltage Offset Correction: v_off_ini = 0.000001238 V, v_off_fin = 0.000005371 V 19:08:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445755 Vs 19:08:27 Integrated Voltage Measurement... 19:08:46 Voltage Offset Correction: v_off_ini = 0.000004951 V, v_off_fin = -0.000002648 V 19:08:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324516 Vs 19:08:49 Temperature Measurement, Probe Number = 0, T = 20.145000 C 19:08:50 Temperature Measurement, Probe Number = 1, T = 20.048000 C 19:08:50 Temperature Measurement, Probe Number = 2, T = 20.012000 C 19:08:51 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:08:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:08:51 Integrated Voltage Measurement... 19:09:10 Voltage Offset Correction: v_off_ini = 0.000001509 V, v_off_fin = 0.000005446 V 19:09:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437579 Vs 19:09:11 Integrated Voltage Measurement... 19:09:30 Voltage Offset Correction: v_off_ini = 0.000004667 V, v_off_fin = -0.000002848 V 19:09:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175325169 Vs 19:09:33 Temperature Measurement, Probe Number = 0, T = 20.161000 C 19:09:34 Temperature Measurement, Probe Number = 1, T = 20.046000 C 19:09:34 Temperature Measurement, Probe Number = 2, T = 20.010000 C 19:09:35 Temperature Measurement, Probe Number = 3, T = 20.000000 C 19:09:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:09:35 Integrated Voltage Measurement... 19:09:54 Voltage Offset Correction: v_off_ini = 0.000001423 V, v_off_fin = 0.000005575 V 19:09:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437490 Vs 19:09:55 Integrated Voltage Measurement... 19:10:14 Voltage Offset Correction: v_off_ini = 0.000005033 V, v_off_fin = -0.000002549 V 19:10:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320490 Vs 19:10:17 Temperature Measurement, Probe Number = 0, T = 20.136000 C 19:10:18 Temperature Measurement, Probe Number = 1, T = 20.049000 C 19:10:18 Temperature Measurement, Probe Number = 2, T = 20.011000 C 19:10:19 Temperature Measurement, Probe Number = 3, T = 19.999000 C 19:10:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:10:19 Integrated Voltage Measurement... 19:10:39 Voltage Offset Correction: v_off_ini = 0.000001857 V, v_off_fin = 0.000006361 V 19:10:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440585 Vs 19:10:39 Integrated Voltage Measurement... 19:10:58 Voltage Offset Correction: v_off_ini = 0.000005234 V, v_off_fin = -0.000001790 V 19:10:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321018 Vs 19:11:01 Temperature Measurement, Probe Number = 0, T = 20.190000 C 19:11:02 Temperature Measurement, Probe Number = 1, T = 20.050000 C 19:11:02 Temperature Measurement, Probe Number = 2, T = 20.012000 C 19:11:03 Temperature Measurement, Probe Number = 3, T = 19.999000 C 19:11:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:11:03 Integrated Voltage Measurement... 19:11:22 Voltage Offset Correction: v_off_ini = 0.000001771 V, v_off_fin = 0.000005611 V 19:11:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439779 Vs 19:11:23 Integrated Voltage Measurement... 19:11:42 Voltage Offset Correction: v_off_ini = 0.000005138 V, v_off_fin = -0.000002450 V 19:11:42 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175321386 Vs 19:41:45 Temperature Measurement, Probe Number = 0, T = 20.220000 C 19:41:45 Temperature Measurement, Probe Number = 1, T = 20.046000 C 19:41:46 Temperature Measurement, Probe Number = 2, T = 20.016000 C 19:41:47 Temperature Measurement, Probe Number = 3, T = 19.999000 C 19:41:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:41:47 Integrated Voltage Measurement... 19:42:06 Voltage Offset Correction: v_off_ini = 0.000003617 V, v_off_fin = 0.000005967 V 19:42:06 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175539727 Vs 19:42:07 Integrated Voltage Measurement... 19:42:25 Voltage Offset Correction: v_off_ini = 0.000005260 V, v_off_fin = -0.000002128 V 19:42:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301385 Vs 19:42:28 Temperature Measurement, Probe Number = 0, T = 20.254000 C 19:42:29 Temperature Measurement, Probe Number = 1, T = 20.047000 C 19:42:30 Temperature Measurement, Probe Number = 2, T = 20.016000 C 19:42:30 Temperature Measurement, Probe Number = 3, T = 19.999000 C 19:42:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:42:31 Integrated Voltage Measurement... 19:42:50 Voltage Offset Correction: v_off_ini = 0.000000915 V, v_off_fin = 0.000006119 V 19:42:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431379 Vs 19:42:50 Integrated Voltage Measurement... 19:43:09 Voltage Offset Correction: v_off_ini = 0.000004726 V, v_off_fin = -0.000002676 V 19:43:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321550 Vs 19:43:12 Temperature Measurement, Probe Number = 0, T = 20.272000 C 19:43:13 Temperature Measurement, Probe Number = 1, T = 20.048000 C 19:43:13 Temperature Measurement, Probe Number = 2, T = 20.017000 C 19:43:14 Temperature Measurement, Probe Number = 3, T = 19.996000 C 19:43:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:43:14 Integrated Voltage Measurement... 19:43:33 Voltage Offset Correction: v_off_ini = 0.000001422 V, v_off_fin = 0.000005366 V 19:43:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430730 Vs 19:43:34 Integrated Voltage Measurement... 19:43:53 Voltage Offset Correction: v_off_ini = 0.000004808 V, v_off_fin = -0.000002569 V 19:43:53 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175306513 Vs 19:43:56 Temperature Measurement, Probe Number = 0, T = 20.260000 C 19:43:56 Temperature Measurement, Probe Number = 1, T = 20.047000 C 19:43:57 Temperature Measurement, Probe Number = 2, T = 20.017000 C 19:43:58 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:43:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:43:58 Integrated Voltage Measurement... 19:44:17 Voltage Offset Correction: v_off_ini = 0.000001526 V, v_off_fin = 0.000005594 V 19:44:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437452 Vs 19:44:18 Integrated Voltage Measurement... 19:44:37 Voltage Offset Correction: v_off_ini = 0.000004946 V, v_off_fin = -0.000001898 V 19:44:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307186 Vs 19:44:40 Temperature Measurement, Probe Number = 0, T = 20.266000 C 19:44:40 Temperature Measurement, Probe Number = 1, T = 20.046000 C 19:44:41 Temperature Measurement, Probe Number = 2, T = 20.015000 C 19:44:42 Temperature Measurement, Probe Number = 3, T = 20.000000 C 19:44:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 19:44:42 Integrated Voltage Measurement... 19:45:01 Voltage Offset Correction: v_off_ini = 0.000002329 V, v_off_fin = 0.000006950 V 19:45:01 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175447583 Vs 19:45:01 Integrated Voltage Measurement... 19:45:20 Voltage Offset Correction: v_off_ini = 0.000006221 V, v_off_fin = -0.000001643 V 19:45:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309938 Vs 19:45:23 Temperature Measurement, Probe Number = 0, T = 20.263000 C 19:45:24 Temperature Measurement, Probe Number = 1, T = 20.045000 C 19:45:25 Temperature Measurement, Probe Number = 2, T = 20.010000 C 19:45:25 Temperature Measurement, Probe Number = 3, T = 19.997000 C 19:45:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:45:25 Integrated Voltage Measurement... 19:45:45 Voltage Offset Correction: v_off_ini = 0.000000962 V, v_off_fin = 0.000005836 V 19:45:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434189 Vs 19:45:45 Integrated Voltage Measurement... 19:46:04 Voltage Offset Correction: v_off_ini = 0.000005150 V, v_off_fin = -0.000001535 V 19:46:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312546 Vs 19:46:07 Temperature Measurement, Probe Number = 0, T = 20.200000 C 19:46:08 Temperature Measurement, Probe Number = 1, T = 20.042000 C 19:46:08 Temperature Measurement, Probe Number = 2, T = 20.011000 C 19:46:09 Temperature Measurement, Probe Number = 3, T = 19.996000 C 19:46:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:46:09 Integrated Voltage Measurement... 19:46:28 Voltage Offset Correction: v_off_ini = 0.000000783 V, v_off_fin = 0.000005184 V 19:46:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430471 Vs 19:46:29 Integrated Voltage Measurement... 19:46:48 Voltage Offset Correction: v_off_ini = 0.000004850 V, v_off_fin = -0.000003264 V 19:46:48 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175320752 Vs 19:46:50 Temperature Measurement, Probe Number = 0, T = 20.200000 C 19:46:51 Temperature Measurement, Probe Number = 1, T = 20.044000 C 19:46:52 Temperature Measurement, Probe Number = 2, T = 20.014000 C 19:46:52 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:46:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:46:53 Integrated Voltage Measurement... 19:47:12 Voltage Offset Correction: v_off_ini = 0.000000849 V, v_off_fin = 0.000006366 V 19:47:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442689 Vs 19:47:12 Integrated Voltage Measurement... 19:47:32 Voltage Offset Correction: v_off_ini = 0.000005120 V, v_off_fin = -0.000001826 V 19:47:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313803 Vs 19:47:34 Temperature Measurement, Probe Number = 0, T = 20.233000 C 19:47:35 Temperature Measurement, Probe Number = 1, T = 20.044000 C 19:47:36 Temperature Measurement, Probe Number = 2, T = 20.010000 C 19:47:36 Temperature Measurement, Probe Number = 3, T = 19.998000 C 19:47:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 19:47:37 Integrated Voltage Measurement... 19:47:56 Voltage Offset Correction: v_off_ini = 0.000001403 V, v_off_fin = 0.000005736 V 19:47:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437974 Vs 19:47:56 Integrated Voltage Measurement... 19:48:16 Voltage Offset Correction: v_off_ini = 0.000005102 V, v_off_fin = -0.000001671 V 19:48:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319908 Vs 19:48:19 Temperature Measurement, Probe Number = 0, T = 20.222000 C 19:48:20 Temperature Measurement, Probe Number = 1, T = 20.041000 C 19:48:20 Temperature Measurement, Probe Number = 2, T = 20.009000 C 19:48:21 Temperature Measurement, Probe Number = 3, T = 19.991000 C 19:48:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 19:48:21 Integrated Voltage Measurement... 19:48:40 Voltage Offset Correction: v_off_ini = 0.000000900 V, v_off_fin = 0.000005804 V 19:48:40 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175429996 Vs 19:48:40 Integrated Voltage Measurement... 19:49:00 Voltage Offset Correction: v_off_ini = 0.000004880 V, v_off_fin = -0.000002201 V 19:49:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317969 Vs 20:19:03 Temperature Measurement, Probe Number = 0, T = 20.287000 C 20:19:03 Temperature Measurement, Probe Number = 1, T = 20.042000 C 20:19:04 Temperature Measurement, Probe Number = 2, T = 20.014000 C 20:19:05 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:19:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:19:05 Integrated Voltage Measurement... 20:19:24 Voltage Offset Correction: v_off_ini = 0.000003407 V, v_off_fin = 0.000005456 V 20:19:24 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175518199 Vs 20:19:24 Integrated Voltage Measurement... 20:19:44 Voltage Offset Correction: v_off_ini = 0.000004874 V, v_off_fin = -0.000002730 V 20:19:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301316 Vs 20:19:46 Temperature Measurement, Probe Number = 0, T = 20.262000 C 20:19:47 Temperature Measurement, Probe Number = 1, T = 20.045000 C 20:19:48 Temperature Measurement, Probe Number = 2, T = 20.015000 C 20:19:48 Temperature Measurement, Probe Number = 3, T = 19.999000 C 20:19:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:19:49 Integrated Voltage Measurement... 20:20:08 Voltage Offset Correction: v_off_ini = 0.000000864 V, v_off_fin = 0.000005200 V 20:20:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412297 Vs 20:20:08 Integrated Voltage Measurement... 20:20:28 Voltage Offset Correction: v_off_ini = 0.000004541 V, v_off_fin = -0.000001449 V 20:20:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300793 Vs 20:20:31 Temperature Measurement, Probe Number = 0, T = 20.268000 C 20:20:31 Temperature Measurement, Probe Number = 1, T = 20.045000 C 20:20:32 Temperature Measurement, Probe Number = 2, T = 20.013000 C 20:20:32 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:20:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:20:33 Integrated Voltage Measurement... 20:20:52 Voltage Offset Correction: v_off_ini = 0.000001201 V, v_off_fin = 0.000006171 V 20:20:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421848 Vs 20:20:52 Integrated Voltage Measurement... 20:21:11 Voltage Offset Correction: v_off_ini = 0.000005856 V, v_off_fin = -0.000002242 V 20:21:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291547 Vs 20:21:14 Temperature Measurement, Probe Number = 0, T = 20.256000 C 20:21:15 Temperature Measurement, Probe Number = 1, T = 20.046000 C 20:21:16 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:21:16 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:21:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:21:16 Integrated Voltage Measurement... 20:21:36 Voltage Offset Correction: v_off_ini = 0.000001036 V, v_off_fin = 0.000005937 V 20:21:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427894 Vs 20:21:37 Integrated Voltage Measurement... 20:21:56 Voltage Offset Correction: v_off_ini = 0.000005297 V, v_off_fin = -0.000002123 V 20:21:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298923 Vs 20:21:59 Temperature Measurement, Probe Number = 0, T = 20.239000 C 20:21:59 Temperature Measurement, Probe Number = 1, T = 20.044000 C 20:22:00 Temperature Measurement, Probe Number = 2, T = 20.016000 C 20:22:01 Temperature Measurement, Probe Number = 3, T = 19.995000 C 20:22:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:22:01 Integrated Voltage Measurement... 20:22:20 Voltage Offset Correction: v_off_ini = 0.000001350 V, v_off_fin = 0.000005814 V 20:22:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417802 Vs 20:22:21 Integrated Voltage Measurement... 20:22:40 Voltage Offset Correction: v_off_ini = 0.000004704 V, v_off_fin = -0.000001874 V 20:22:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295165 Vs 20:22:43 Temperature Measurement, Probe Number = 0, T = 20.210000 C 20:22:43 Temperature Measurement, Probe Number = 1, T = 20.041000 C 20:22:44 Temperature Measurement, Probe Number = 2, T = 20.012000 C 20:22:45 Temperature Measurement, Probe Number = 3, T = 19.996000 C 20:22:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:22:45 Integrated Voltage Measurement... 20:23:04 Voltage Offset Correction: v_off_ini = 0.000001764 V, v_off_fin = 0.000006152 V 20:23:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416467 Vs 20:23:05 Integrated Voltage Measurement... 20:23:24 Voltage Offset Correction: v_off_ini = 0.000004999 V, v_off_fin = -0.000001963 V 20:23:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300069 Vs 20:23:27 Temperature Measurement, Probe Number = 0, T = 20.145000 C 20:23:28 Temperature Measurement, Probe Number = 1, T = 20.039000 C 20:23:28 Temperature Measurement, Probe Number = 2, T = 20.009000 C 20:23:29 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:23:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 20:23:29 Integrated Voltage Measurement... 20:23:48 Voltage Offset Correction: v_off_ini = 0.000001178 V, v_off_fin = 0.000005966 V 20:23:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415339 Vs 20:23:49 Integrated Voltage Measurement... 20:24:08 Voltage Offset Correction: v_off_ini = 0.000005092 V, v_off_fin = -0.000002422 V 20:24:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307600 Vs 20:24:11 Temperature Measurement, Probe Number = 0, T = 20.131000 C 20:24:12 Temperature Measurement, Probe Number = 1, T = 20.041000 C 20:24:12 Temperature Measurement, Probe Number = 2, T = 20.013000 C 20:24:13 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:24:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:24:13 Integrated Voltage Measurement... 20:24:32 Voltage Offset Correction: v_off_ini = 0.000001807 V, v_off_fin = 0.000005957 V 20:24:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175414092 Vs 20:24:33 Integrated Voltage Measurement... 20:24:52 Voltage Offset Correction: v_off_ini = 0.000005346 V, v_off_fin = -0.000002682 V 20:24:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297331 Vs 20:24:55 Temperature Measurement, Probe Number = 0, T = 20.139000 C 20:24:56 Temperature Measurement, Probe Number = 1, T = 20.041000 C 20:24:56 Temperature Measurement, Probe Number = 2, T = 20.013000 C 20:24:57 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:24:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:24:57 Integrated Voltage Measurement... 20:25:16 Voltage Offset Correction: v_off_ini = 0.000001627 V, v_off_fin = 0.000005674 V 20:25:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419035 Vs 20:25:17 Integrated Voltage Measurement... 20:25:35 Voltage Offset Correction: v_off_ini = 0.000005300 V, v_off_fin = -0.000002846 V 20:25:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175293627 Vs 20:25:38 Temperature Measurement, Probe Number = 0, T = 20.196000 C 20:25:39 Temperature Measurement, Probe Number = 1, T = 20.042000 C 20:25:40 Temperature Measurement, Probe Number = 2, T = 20.015000 C 20:25:40 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:25:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 20:25:41 Integrated Voltage Measurement... 20:26:00 Voltage Offset Correction: v_off_ini = 0.000001169 V, v_off_fin = 0.000005398 V 20:26:00 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175422724 Vs 20:26:00 Integrated Voltage Measurement... 20:26:19 Voltage Offset Correction: v_off_ini = 0.000005497 V, v_off_fin = -0.000001924 V 20:26:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294443 Vs 20:56:22 Temperature Measurement, Probe Number = 0, T = 20.297000 C 20:56:23 Temperature Measurement, Probe Number = 1, T = 20.040000 C 20:56:23 Temperature Measurement, Probe Number = 2, T = 20.010000 C 20:56:24 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:56:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 20:56:24 Integrated Voltage Measurement... 20:56:43 Voltage Offset Correction: v_off_ini = 0.000003538 V, v_off_fin = 0.000005745 V 20:56:43 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175508257 Vs 20:56:44 Integrated Voltage Measurement... 20:57:03 Voltage Offset Correction: v_off_ini = 0.000004787 V, v_off_fin = -0.000002618 V 20:57:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296963 Vs 20:57:06 Temperature Measurement, Probe Number = 0, T = 20.265000 C 20:57:07 Temperature Measurement, Probe Number = 1, T = 20.038000 C 20:57:07 Temperature Measurement, Probe Number = 2, T = 20.011000 C 20:57:08 Temperature Measurement, Probe Number = 3, T = 19.995000 C 20:57:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:57:08 Integrated Voltage Measurement... 20:57:27 Voltage Offset Correction: v_off_ini = 0.000000661 V, v_off_fin = 0.000005859 V 20:57:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409085 Vs 20:57:28 Integrated Voltage Measurement... 20:57:47 Voltage Offset Correction: v_off_ini = 0.000004766 V, v_off_fin = -0.000002080 V 20:57:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291132 Vs 20:57:50 Temperature Measurement, Probe Number = 0, T = 20.233000 C 20:57:51 Temperature Measurement, Probe Number = 1, T = 20.040000 C 20:57:51 Temperature Measurement, Probe Number = 2, T = 20.013000 C 20:57:52 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:57:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 20:57:52 Integrated Voltage Measurement... 20:58:11 Voltage Offset Correction: v_off_ini = 0.000001267 V, v_off_fin = 0.000006256 V 20:58:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410002 Vs 20:58:11 Integrated Voltage Measurement... 20:58:30 Voltage Offset Correction: v_off_ini = 0.000005082 V, v_off_fin = -0.000002260 V 20:58:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285160 Vs 20:58:33 Temperature Measurement, Probe Number = 0, T = 20.239000 C 20:58:34 Temperature Measurement, Probe Number = 1, T = 20.041000 C 20:58:35 Temperature Measurement, Probe Number = 2, T = 20.013000 C 20:58:35 Temperature Measurement, Probe Number = 3, T = 19.997000 C 20:58:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 20:58:35 Integrated Voltage Measurement... 20:58:55 Voltage Offset Correction: v_off_ini = 0.000001599 V, v_off_fin = 0.000005510 V 20:58:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408387 Vs 20:58:55 Integrated Voltage Measurement... 20:59:14 Voltage Offset Correction: v_off_ini = 0.000004828 V, v_off_fin = -0.000002560 V 20:59:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293767 Vs 20:59:17 Temperature Measurement, Probe Number = 0, T = 20.267000 C 20:59:18 Temperature Measurement, Probe Number = 1, T = 20.040000 C 20:59:18 Temperature Measurement, Probe Number = 2, T = 20.011000 C 20:59:19 Temperature Measurement, Probe Number = 3, T = 19.994000 C 20:59:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 20:59:19 Integrated Voltage Measurement... 20:59:38 Voltage Offset Correction: v_off_ini = 0.000001188 V, v_off_fin = 0.000005461 V 20:59:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407642 Vs 20:59:39 Integrated Voltage Measurement... 20:59:58 Voltage Offset Correction: v_off_ini = 0.000004756 V, v_off_fin = -0.000002695 V 20:59:58 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175292626 Vs 21:00:00 Temperature Measurement, Probe Number = 0, T = 20.198000 C 21:00:01 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:00:02 Temperature Measurement, Probe Number = 2, T = 20.012000 C 21:00:02 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:00:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:00:03 Integrated Voltage Measurement... 21:00:22 Voltage Offset Correction: v_off_ini = 0.000001385 V, v_off_fin = 0.000005505 V 21:00:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175404991 Vs 21:00:22 Integrated Voltage Measurement... 21:00:41 Voltage Offset Correction: v_off_ini = 0.000004286 V, v_off_fin = -0.000002731 V 21:00:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301946 Vs 21:00:44 Temperature Measurement, Probe Number = 0, T = 20.182000 C 21:00:45 Temperature Measurement, Probe Number = 1, T = 20.043000 C 21:00:46 Temperature Measurement, Probe Number = 2, T = 20.014000 C 21:00:46 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:00:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:00:46 Integrated Voltage Measurement... 21:01:06 Voltage Offset Correction: v_off_ini = 0.000001208 V, v_off_fin = 0.000005665 V 21:01:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411097 Vs 21:01:06 Integrated Voltage Measurement... 21:01:25 Voltage Offset Correction: v_off_ini = 0.000005040 V, v_off_fin = -0.000002418 V 21:01:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300415 Vs 21:01:28 Temperature Measurement, Probe Number = 0, T = 20.187000 C 21:01:29 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:01:30 Temperature Measurement, Probe Number = 2, T = 20.015000 C 21:01:30 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:01:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 21:01:31 Integrated Voltage Measurement... 21:01:50 Voltage Offset Correction: v_off_ini = 0.000001242 V, v_off_fin = 0.000005458 V 21:01:50 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410358 Vs 21:01:50 Integrated Voltage Measurement... 21:02:09 Voltage Offset Correction: v_off_ini = 0.000004959 V, v_off_fin = -0.000002070 V 21:02:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299751 Vs 21:02:12 Temperature Measurement, Probe Number = 0, T = 20.163000 C 21:02:13 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:02:14 Temperature Measurement, Probe Number = 2, T = 20.014000 C 21:02:14 Temperature Measurement, Probe Number = 3, T = 19.998000 C 21:02:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:02:14 Integrated Voltage Measurement... 21:02:34 Voltage Offset Correction: v_off_ini = 0.000001085 V, v_off_fin = 0.000006010 V 21:02:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418031 Vs 21:02:35 Integrated Voltage Measurement... 21:02:54 Voltage Offset Correction: v_off_ini = 0.000004994 V, v_off_fin = -0.000002309 V 21:02:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280170 Vs 21:02:57 Temperature Measurement, Probe Number = 0, T = 20.136000 C 21:02:57 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:02:58 Temperature Measurement, Probe Number = 2, T = 20.012000 C 21:02:59 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:02:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:02:59 Integrated Voltage Measurement... 21:03:18 Voltage Offset Correction: v_off_ini = 0.000001703 V, v_off_fin = 0.000006136 V 21:03:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413481 Vs 21:03:18 Integrated Voltage Measurement... 21:03:38 Voltage Offset Correction: v_off_ini = 0.000005221 V, v_off_fin = -0.000002665 V 21:03:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293019 Vs 21:33:40 Temperature Measurement, Probe Number = 0, T = 20.180000 C 21:33:41 Temperature Measurement, Probe Number = 1, T = 20.035000 C 21:33:42 Temperature Measurement, Probe Number = 2, T = 20.004000 C 21:33:42 Temperature Measurement, Probe Number = 3, T = 19.990000 C 21:33:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 21:33:43 Integrated Voltage Measurement... 21:34:02 Voltage Offset Correction: v_off_ini = 0.000004082 V, v_off_fin = 0.000006360 V 21:34:02 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175506146 Vs 21:34:02 Integrated Voltage Measurement... 21:34:22 Voltage Offset Correction: v_off_ini = 0.000005628 V, v_off_fin = -0.000001576 V 21:34:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293341 Vs 21:34:24 Temperature Measurement, Probe Number = 0, T = 20.208000 C 21:34:25 Temperature Measurement, Probe Number = 1, T = 20.037000 C 21:34:26 Temperature Measurement, Probe Number = 2, T = 20.008000 C 21:34:26 Temperature Measurement, Probe Number = 3, T = 19.997000 C 21:34:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:34:27 Integrated Voltage Measurement... 21:34:46 Voltage Offset Correction: v_off_ini = 0.000001030 V, v_off_fin = 0.000005678 V 21:34:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408703 Vs 21:34:46 Integrated Voltage Measurement... 21:35:05 Voltage Offset Correction: v_off_ini = 0.000004814 V, v_off_fin = -0.000001883 V 21:35:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285963 Vs 21:35:08 Temperature Measurement, Probe Number = 0, T = 20.228000 C 21:35:09 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:35:10 Temperature Measurement, Probe Number = 2, T = 20.007000 C 21:35:10 Temperature Measurement, Probe Number = 3, T = 19.992000 C 21:35:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:35:10 Integrated Voltage Measurement... 21:35:30 Voltage Offset Correction: v_off_ini = 0.000001431 V, v_off_fin = 0.000005700 V 21:35:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417330 Vs 21:35:31 Integrated Voltage Measurement... 21:35:50 Voltage Offset Correction: v_off_ini = 0.000005008 V, v_off_fin = -0.000002366 V 21:35:50 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175291669 Vs 21:35:53 Temperature Measurement, Probe Number = 0, T = 20.235000 C 21:35:54 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:35:55 Temperature Measurement, Probe Number = 2, T = 20.009000 C 21:35:56 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:35:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:35:56 Integrated Voltage Measurement... 21:36:15 Voltage Offset Correction: v_off_ini = 0.000001198 V, v_off_fin = 0.000005629 V 21:36:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409526 Vs 21:36:16 Integrated Voltage Measurement... 21:36:36 Voltage Offset Correction: v_off_ini = 0.000004740 V, v_off_fin = -0.000002067 V 21:36:37 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175304252 Vs 21:36:40 Temperature Measurement, Probe Number = 0, T = 20.212000 C 21:36:41 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:36:42 Temperature Measurement, Probe Number = 2, T = 20.010000 C 21:36:42 Temperature Measurement, Probe Number = 3, T = 19.994000 C 21:36:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:36:42 Integrated Voltage Measurement... 21:37:02 Voltage Offset Correction: v_off_ini = 0.000001956 V, v_off_fin = 0.000005361 V 21:37:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411958 Vs 21:37:03 Integrated Voltage Measurement... 21:37:22 Voltage Offset Correction: v_off_ini = 0.000004500 V, v_off_fin = -0.000002509 V 21:37:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297855 Vs 21:37:25 Temperature Measurement, Probe Number = 0, T = 20.165000 C 21:37:26 Temperature Measurement, Probe Number = 1, T = 20.038000 C 21:37:26 Temperature Measurement, Probe Number = 2, T = 20.008000 C 21:37:27 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:37:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:37:27 Integrated Voltage Measurement... 21:37:47 Voltage Offset Correction: v_off_ini = 0.000001236 V, v_off_fin = 0.000005376 V 21:37:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414839 Vs 21:37:47 Integrated Voltage Measurement... 21:38:06 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000002282 V 21:38:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294941 Vs 21:38:09 Temperature Measurement, Probe Number = 0, T = 20.159000 C 21:38:10 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:38:10 Temperature Measurement, Probe Number = 2, T = 20.011000 C 21:38:11 Temperature Measurement, Probe Number = 3, T = 19.995000 C 21:38:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:38:11 Integrated Voltage Measurement... 21:38:31 Voltage Offset Correction: v_off_ini = 0.000001421 V, v_off_fin = 0.000005236 V 21:38:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411469 Vs 21:38:32 Integrated Voltage Measurement... 21:38:51 Voltage Offset Correction: v_off_ini = 0.000004667 V, v_off_fin = -0.000002732 V 21:38:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294454 Vs 21:38:54 Temperature Measurement, Probe Number = 0, T = 20.199000 C 21:38:54 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:38:55 Temperature Measurement, Probe Number = 2, T = 20.010000 C 21:38:56 Temperature Measurement, Probe Number = 3, T = 19.995000 C 21:38:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:38:56 Integrated Voltage Measurement... 21:39:15 Voltage Offset Correction: v_off_ini = 0.000000996 V, v_off_fin = 0.000005241 V 21:39:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408620 Vs 21:39:16 Integrated Voltage Measurement... 21:39:35 Voltage Offset Correction: v_off_ini = 0.000004557 V, v_off_fin = -0.000002966 V 21:39:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303446 Vs 21:39:38 Temperature Measurement, Probe Number = 0, T = 20.182000 C 21:39:39 Temperature Measurement, Probe Number = 1, T = 20.037000 C 21:39:39 Temperature Measurement, Probe Number = 2, T = 20.008000 C 21:39:40 Temperature Measurement, Probe Number = 3, T = 19.993000 C 21:39:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 21:39:40 Integrated Voltage Measurement... 21:39:59 Voltage Offset Correction: v_off_ini = 0.000001028 V, v_off_fin = 0.000005313 V 21:39:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410014 Vs 21:39:59 Integrated Voltage Measurement... 21:40:18 Voltage Offset Correction: v_off_ini = 0.000004523 V, v_off_fin = -0.000002785 V 21:40:18 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175300048 Vs 21:40:21 Temperature Measurement, Probe Number = 0, T = 20.192000 C 21:40:22 Temperature Measurement, Probe Number = 1, T = 20.040000 C 21:40:23 Temperature Measurement, Probe Number = 2, T = 20.009000 C 21:40:23 Temperature Measurement, Probe Number = 3, T = 19.996000 C 21:40:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 20.00 21:40:23 Integrated Voltage Measurement... 21:40:42 Voltage Offset Correction: v_off_ini = 0.000000725 V, v_off_fin = 0.000005072 V 21:40:43 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175413837 Vs 21:40:43 Integrated Voltage Measurement... 21:41:02 Voltage Offset Correction: v_off_ini = 0.000004693 V, v_off_fin = -0.000002991 V 21:41:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305618 Vs 22:11:05 Temperature Measurement, Probe Number = 0, T = 20.259000 C 22:11:06 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:11:06 Temperature Measurement, Probe Number = 2, T = 20.007000 C 22:11:07 Temperature Measurement, Probe Number = 3, T = 19.990000 C 22:11:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 22:11:07 Integrated Voltage Measurement... 22:11:26 Voltage Offset Correction: v_off_ini = 0.000003629 V, v_off_fin = 0.000005898 V 22:11:26 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175498372 Vs 22:11:27 Integrated Voltage Measurement... 22:11:46 Voltage Offset Correction: v_off_ini = 0.000005025 V, v_off_fin = -0.000002151 V 22:11:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294342 Vs 22:11:49 Temperature Measurement, Probe Number = 0, T = 20.227000 C 22:11:50 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:11:50 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:11:51 Temperature Measurement, Probe Number = 3, T = 19.990000 C 22:11:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:11:51 Integrated Voltage Measurement... 22:12:10 Voltage Offset Correction: v_off_ini = 0.000001279 V, v_off_fin = 0.000005433 V 22:12:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409572 Vs 22:12:11 Integrated Voltage Measurement... 22:12:30 Voltage Offset Correction: v_off_ini = 0.000004823 V, v_off_fin = -0.000002044 V 22:12:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301100 Vs 22:12:33 Temperature Measurement, Probe Number = 0, T = 20.156000 C 22:12:33 Temperature Measurement, Probe Number = 1, T = 20.030000 C 22:12:34 Temperature Measurement, Probe Number = 2, T = 20.000000 C 22:12:35 Temperature Measurement, Probe Number = 3, T = 19.987000 C 22:12:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:12:35 Integrated Voltage Measurement... 22:12:54 Voltage Offset Correction: v_off_ini = 0.000001122 V, v_off_fin = 0.000005780 V 22:12:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423381 Vs 22:12:55 Integrated Voltage Measurement... 22:13:14 Voltage Offset Correction: v_off_ini = 0.000005236 V, v_off_fin = -0.000002614 V 22:13:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302839 Vs 22:13:17 Temperature Measurement, Probe Number = 0, T = 20.081000 C 22:13:18 Temperature Measurement, Probe Number = 1, T = 20.031000 C 22:13:18 Temperature Measurement, Probe Number = 2, T = 19.997000 C 22:13:19 Temperature Measurement, Probe Number = 3, T = 19.985000 C 22:13:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:13:19 Integrated Voltage Measurement... 22:13:38 Voltage Offset Correction: v_off_ini = 0.000001619 V, v_off_fin = 0.000005778 V 22:13:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418117 Vs 22:13:39 Integrated Voltage Measurement... 22:13:58 Voltage Offset Correction: v_off_ini = 0.000005455 V, v_off_fin = -0.000002341 V 22:13:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302065 Vs 22:14:01 Temperature Measurement, Probe Number = 0, T = 20.103000 C 22:14:02 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:14:02 Temperature Measurement, Probe Number = 2, T = 20.001000 C 22:14:03 Temperature Measurement, Probe Number = 3, T = 19.991000 C 22:14:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:14:03 Integrated Voltage Measurement... 22:14:22 Voltage Offset Correction: v_off_ini = 0.000001353 V, v_off_fin = 0.000005994 V 22:14:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420535 Vs 22:14:22 Integrated Voltage Measurement... 22:14:42 Voltage Offset Correction: v_off_ini = 0.000004744 V, v_off_fin = -0.000001843 V 22:14:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299320 Vs 22:14:44 Temperature Measurement, Probe Number = 0, T = 20.196000 C 22:14:45 Temperature Measurement, Probe Number = 1, T = 20.033000 C 22:14:46 Temperature Measurement, Probe Number = 2, T = 20.003000 C 22:14:46 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:14:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:14:47 Integrated Voltage Measurement... 22:15:06 Voltage Offset Correction: v_off_ini = 0.000000840 V, v_off_fin = 0.000005404 V 22:15:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415617 Vs 22:15:06 Integrated Voltage Measurement... 22:15:25 Voltage Offset Correction: v_off_ini = 0.000004697 V, v_off_fin = -0.000001808 V 22:15:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303471 Vs 22:15:28 Temperature Measurement, Probe Number = 0, T = 20.244000 C 22:15:29 Temperature Measurement, Probe Number = 1, T = 20.035000 C 22:15:29 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:15:30 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:15:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:15:30 Integrated Voltage Measurement... 22:15:49 Voltage Offset Correction: v_off_ini = 0.000000599 V, v_off_fin = 0.000005402 V 22:15:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417120 Vs 22:15:50 Integrated Voltage Measurement... 22:16:09 Voltage Offset Correction: v_off_ini = 0.000005319 V, v_off_fin = -0.000002661 V 22:16:09 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175302733 Vs 22:16:12 Temperature Measurement, Probe Number = 0, T = 20.275000 C 22:16:13 Temperature Measurement, Probe Number = 1, T = 20.035000 C 22:16:13 Temperature Measurement, Probe Number = 2, T = 20.005000 C 22:16:14 Temperature Measurement, Probe Number = 3, T = 19.992000 C 22:16:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:16:14 Integrated Voltage Measurement... 22:16:33 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000005777 V 22:16:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422208 Vs 22:16:34 Integrated Voltage Measurement... 22:16:53 Voltage Offset Correction: v_off_ini = 0.000005434 V, v_off_fin = -0.000002091 V 22:16:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294628 Vs 22:16:56 Temperature Measurement, Probe Number = 0, T = 20.266000 C 22:16:56 Temperature Measurement, Probe Number = 1, T = 20.030000 C 22:16:57 Temperature Measurement, Probe Number = 2, T = 19.999000 C 22:16:58 Temperature Measurement, Probe Number = 3, T = 19.986000 C 22:16:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:16:58 Integrated Voltage Measurement... 22:17:17 Voltage Offset Correction: v_off_ini = 0.000001471 V, v_off_fin = 0.000006064 V 22:17:17 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175419219 Vs 22:17:17 Integrated Voltage Measurement... 22:17:37 Voltage Offset Correction: v_off_ini = 0.000004956 V, v_off_fin = -0.000001520 V 22:17:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307382 Vs 22:17:39 Temperature Measurement, Probe Number = 0, T = 20.199000 C 22:17:40 Temperature Measurement, Probe Number = 1, T = 20.032000 C 22:17:41 Temperature Measurement, Probe Number = 2, T = 20.004000 C 22:17:41 Temperature Measurement, Probe Number = 3, T = 19.990000 C 22:17:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:17:42 Integrated Voltage Measurement... 22:18:01 Voltage Offset Correction: v_off_ini = 0.000002008 V, v_off_fin = 0.000005885 V 22:18:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418097 Vs 22:18:02 Integrated Voltage Measurement... 22:18:21 Voltage Offset Correction: v_off_ini = 0.000005092 V, v_off_fin = -0.000002418 V 22:18:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294024 Vs 22:48:24 Temperature Measurement, Probe Number = 0, T = 20.110000 C 22:48:25 Temperature Measurement, Probe Number = 1, T = 20.026000 C 22:48:25 Temperature Measurement, Probe Number = 2, T = 19.996000 C 22:48:26 Temperature Measurement, Probe Number = 3, T = 19.984000 C 22:48:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:48:26 Integrated Voltage Measurement... 22:48:45 Voltage Offset Correction: v_off_ini = 0.000003460 V, v_off_fin = 0.000006045 V 22:48:45 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175515620 Vs 22:48:46 Integrated Voltage Measurement... 22:49:05 Voltage Offset Correction: v_off_ini = 0.000005485 V, v_off_fin = -0.000002361 V 22:49:05 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175295079 Vs 22:49:07 Temperature Measurement, Probe Number = 0, T = 20.111000 C 22:49:08 Temperature Measurement, Probe Number = 1, T = 20.026000 C 22:49:09 Temperature Measurement, Probe Number = 2, T = 19.994000 C 22:49:09 Temperature Measurement, Probe Number = 3, T = 19.984000 C 22:49:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 22:49:10 Integrated Voltage Measurement... 22:49:29 Voltage Offset Correction: v_off_ini = 0.000001646 V, v_off_fin = 0.000005783 V 22:49:29 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175424614 Vs 22:49:29 Integrated Voltage Measurement... 22:49:48 Voltage Offset Correction: v_off_ini = 0.000005441 V, v_off_fin = -0.000002329 V 22:49:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302924 Vs 22:49:51 Temperature Measurement, Probe Number = 0, T = 20.096000 C 22:49:52 Temperature Measurement, Probe Number = 1, T = 20.027000 C 22:49:52 Temperature Measurement, Probe Number = 2, T = 19.995000 C 22:49:53 Temperature Measurement, Probe Number = 3, T = 19.984000 C 22:49:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:49:53 Integrated Voltage Measurement... 22:50:12 Voltage Offset Correction: v_off_ini = 0.000001708 V, v_off_fin = 0.000005698 V 22:50:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425325 Vs 22:50:13 Integrated Voltage Measurement... 22:50:32 Voltage Offset Correction: v_off_ini = 0.000005416 V, v_off_fin = -0.000002281 V 22:50:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296199 Vs 22:50:35 Temperature Measurement, Probe Number = 0, T = 20.141000 C 22:50:35 Temperature Measurement, Probe Number = 1, T = 20.029000 C 22:50:36 Temperature Measurement, Probe Number = 2, T = 19.998000 C 22:50:37 Temperature Measurement, Probe Number = 3, T = 19.987000 C 22:50:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:50:37 Integrated Voltage Measurement... 22:50:56 Voltage Offset Correction: v_off_ini = 0.000001500 V, v_off_fin = 0.000006105 V 22:50:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425695 Vs 22:50:56 Integrated Voltage Measurement... 22:51:16 Voltage Offset Correction: v_off_ini = 0.000005552 V, v_off_fin = -0.000001821 V 22:51:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305209 Vs 22:51:18 Temperature Measurement, Probe Number = 0, T = 20.133000 C 22:51:19 Temperature Measurement, Probe Number = 1, T = 20.028000 C 22:51:20 Temperature Measurement, Probe Number = 2, T = 19.999000 C 22:51:20 Temperature Measurement, Probe Number = 3, T = 19.985000 C 22:51:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:51:21 Integrated Voltage Measurement... 22:51:40 Voltage Offset Correction: v_off_ini = 0.000002284 V, v_off_fin = 0.000006069 V 22:51:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419876 Vs 22:51:40 Integrated Voltage Measurement... 22:51:59 Voltage Offset Correction: v_off_ini = 0.000004875 V, v_off_fin = -0.000002608 V 22:51:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293546 Vs 22:52:02 Temperature Measurement, Probe Number = 0, T = 20.108000 C 22:52:03 Temperature Measurement, Probe Number = 1, T = 20.027000 C 22:52:03 Temperature Measurement, Probe Number = 2, T = 19.998000 C 22:52:04 Temperature Measurement, Probe Number = 3, T = 19.983000 C 22:52:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:52:04 Integrated Voltage Measurement... 22:52:24 Voltage Offset Correction: v_off_ini = 0.000000334 V, v_off_fin = 0.000005370 V 22:52:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417263 Vs 22:52:24 Integrated Voltage Measurement... 22:52:43 Voltage Offset Correction: v_off_ini = 0.000004767 V, v_off_fin = -0.000002186 V 22:52:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296826 Vs 22:52:46 Temperature Measurement, Probe Number = 0, T = 20.115000 C 22:52:47 Temperature Measurement, Probe Number = 1, T = 20.028000 C 22:52:47 Temperature Measurement, Probe Number = 2, T = 19.997000 C 22:52:48 Temperature Measurement, Probe Number = 3, T = 19.984000 C 22:52:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:52:48 Integrated Voltage Measurement... 22:53:07 Voltage Offset Correction: v_off_ini = 0.000001376 V, v_off_fin = 0.000006025 V 22:53:07 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175418874 Vs 22:53:07 Integrated Voltage Measurement... 22:53:27 Voltage Offset Correction: v_off_ini = 0.000005274 V, v_off_fin = 0.000000000 V 22:53:27 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175293707 Vs 22:53:30 Temperature Measurement, Probe Number = 0, T = 20.106000 C 22:53:31 Temperature Measurement, Probe Number = 1, T = 20.026000 C 22:53:31 Temperature Measurement, Probe Number = 2, T = 19.999000 C 22:53:32 Temperature Measurement, Probe Number = 3, T = 19.985000 C 22:53:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 22:53:32 Integrated Voltage Measurement... 22:53:53 Voltage Offset Correction: v_off_ini = 0.000001985 V, v_off_fin = 0.000005164 V 22:53:53 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175410099 Vs 22:53:53 Integrated Voltage Measurement... 22:54:13 Voltage Offset Correction: v_off_ini = 0.000004673 V, v_off_fin = -0.000001280 V 22:54:13 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175300959 Vs 22:54:16 Temperature Measurement, Probe Number = 0, T = 20.027000 C 22:54:16 Temperature Measurement, Probe Number = 1, T = 20.027000 C 22:54:17 Temperature Measurement, Probe Number = 2, T = 20.000000 C 22:54:17 Temperature Measurement, Probe Number = 3, T = 19.986000 C 22:54:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:54:18 Integrated Voltage Measurement... 22:54:37 Voltage Offset Correction: v_off_ini = 0.000001615 V, v_off_fin = 0.000005786 V 22:54:37 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414063 Vs 22:54:37 Integrated Voltage Measurement... 22:54:56 Voltage Offset Correction: v_off_ini = 0.000005206 V, v_off_fin = -0.000001872 V 22:54:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297272 Vs 22:54:59 Temperature Measurement, Probe Number = 0, T = 19.957000 C 22:55:00 Temperature Measurement, Probe Number = 1, T = 20.030000 C 22:55:01 Temperature Measurement, Probe Number = 2, T = 20.002000 C 22:55:01 Temperature Measurement, Probe Number = 3, T = 19.986000 C 22:55:01 Magnet Test Parameter Measurements P0 = Room, Value = 19.96 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 22:55:01 Integrated Voltage Measurement... 22:55:20 Voltage Offset Correction: v_off_ini = 0.000001143 V, v_off_fin = 0.000005758 V 22:55:20 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175422863 Vs 22:55:21 Integrated Voltage Measurement... 22:55:40 Voltage Offset Correction: v_off_ini = 0.000005364 V, v_off_fin = -0.000002254 V 22:55:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304969 Vs 23:25:43 Temperature Measurement, Probe Number = 0, T = 20.110000 C 23:25:43 Temperature Measurement, Probe Number = 1, T = 20.023000 C 23:25:44 Temperature Measurement, Probe Number = 2, T = 19.989000 C 23:25:45 Temperature Measurement, Probe Number = 3, T = 19.978000 C 23:25:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:25:45 Integrated Voltage Measurement... 23:26:04 Voltage Offset Correction: v_off_ini = 0.000003748 V, v_off_fin = 0.000006409 V 23:26:04 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175510940 Vs 23:26:04 Integrated Voltage Measurement... 23:26:24 Voltage Offset Correction: v_off_ini = 0.000005145 V, v_off_fin = -0.000002368 V 23:26:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296515 Vs 23:26:27 Temperature Measurement, Probe Number = 0, T = 20.124000 C 23:26:28 Temperature Measurement, Probe Number = 1, T = 20.025000 C 23:26:28 Temperature Measurement, Probe Number = 2, T = 19.992000 C 23:26:29 Temperature Measurement, Probe Number = 3, T = 19.982000 C 23:26:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:26:29 Integrated Voltage Measurement... 23:26:48 Voltage Offset Correction: v_off_ini = 0.000000655 V, v_off_fin = 0.000005939 V 23:26:48 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175407537 Vs 23:26:48 Integrated Voltage Measurement... 23:27:08 Voltage Offset Correction: v_off_ini = 0.000005148 V, v_off_fin = -0.000001964 V 23:27:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303691 Vs 23:27:11 Temperature Measurement, Probe Number = 0, T = 20.173000 C 23:27:11 Temperature Measurement, Probe Number = 1, T = 20.026000 C 23:27:12 Temperature Measurement, Probe Number = 2, T = 19.993000 C 23:27:13 Temperature Measurement, Probe Number = 3, T = 19.983000 C 23:27:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:27:13 Integrated Voltage Measurement... 23:27:32 Voltage Offset Correction: v_off_ini = 0.000000755 V, v_off_fin = 0.000005423 V 23:27:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414002 Vs 23:27:32 Integrated Voltage Measurement... 23:27:52 Voltage Offset Correction: v_off_ini = 0.000004449 V, v_off_fin = -0.000002020 V 23:27:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308192 Vs 23:27:55 Temperature Measurement, Probe Number = 0, T = 20.170000 C 23:27:55 Temperature Measurement, Probe Number = 1, T = 20.023000 C 23:27:56 Temperature Measurement, Probe Number = 2, T = 19.992000 C 23:27:57 Temperature Measurement, Probe Number = 3, T = 19.982000 C 23:27:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:27:57 Integrated Voltage Measurement... 23:28:16 Voltage Offset Correction: v_off_ini = 0.000000742 V, v_off_fin = 0.000005653 V 23:28:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413285 Vs 23:28:16 Integrated Voltage Measurement... 23:28:35 Voltage Offset Correction: v_off_ini = 0.000005146 V, v_off_fin = -0.000002572 V 23:28:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293484 Vs 23:28:38 Temperature Measurement, Probe Number = 0, T = 20.169000 C 23:28:39 Temperature Measurement, Probe Number = 1, T = 20.023000 C 23:28:39 Temperature Measurement, Probe Number = 2, T = 19.990000 C 23:28:40 Temperature Measurement, Probe Number = 3, T = 19.978000 C 23:28:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:28:40 Integrated Voltage Measurement... 23:28:59 Voltage Offset Correction: v_off_ini = 0.000001372 V, v_off_fin = 0.000005875 V 23:29:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420733 Vs 23:29:00 Integrated Voltage Measurement... 23:29:19 Voltage Offset Correction: v_off_ini = 0.000005044 V, v_off_fin = -0.000001524 V 23:29:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299195 Vs 23:29:22 Temperature Measurement, Probe Number = 0, T = 20.155000 C 23:29:23 Temperature Measurement, Probe Number = 1, T = 20.025000 C 23:29:23 Temperature Measurement, Probe Number = 2, T = 19.990000 C 23:29:24 Temperature Measurement, Probe Number = 3, T = 19.981000 C 23:29:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:29:24 Integrated Voltage Measurement... 23:29:43 Voltage Offset Correction: v_off_ini = 0.000001905 V, v_off_fin = 0.000005585 V 23:29:43 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414416 Vs 23:29:44 Integrated Voltage Measurement... 23:30:03 Voltage Offset Correction: v_off_ini = 0.000005081 V, v_off_fin = -0.000002069 V 23:30:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293191 Vs 23:30:05 Temperature Measurement, Probe Number = 0, T = 20.166000 C 23:30:06 Temperature Measurement, Probe Number = 1, T = 20.023000 C 23:30:07 Temperature Measurement, Probe Number = 2, T = 19.990000 C 23:30:07 Temperature Measurement, Probe Number = 3, T = 19.979000 C 23:30:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:30:08 Integrated Voltage Measurement... 23:30:27 Voltage Offset Correction: v_off_ini = 0.000001144 V, v_off_fin = 0.000005397 V 23:30:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424424 Vs 23:30:27 Integrated Voltage Measurement... 23:30:46 Voltage Offset Correction: v_off_ini = 0.000004779 V, v_off_fin = -0.000002348 V 23:30:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300361 Vs 23:30:49 Temperature Measurement, Probe Number = 0, T = 20.147000 C 23:30:50 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:30:51 Temperature Measurement, Probe Number = 2, T = 19.991000 C 23:30:51 Temperature Measurement, Probe Number = 3, T = 19.979000 C 23:30:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:30:52 Integrated Voltage Measurement... 23:31:11 Voltage Offset Correction: v_off_ini = 0.000001243 V, v_off_fin = 0.000005698 V 23:31:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417183 Vs 23:31:11 Integrated Voltage Measurement... 23:31:30 Voltage Offset Correction: v_off_ini = 0.000005172 V, v_off_fin = -0.000001723 V 23:31:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298709 Vs 23:31:33 Temperature Measurement, Probe Number = 0, T = 20.122000 C 23:31:34 Temperature Measurement, Probe Number = 1, T = 20.022000 C 23:31:34 Temperature Measurement, Probe Number = 2, T = 19.990000 C 23:31:35 Temperature Measurement, Probe Number = 3, T = 19.980000 C 23:31:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:31:35 Integrated Voltage Measurement... 23:33:15 Voltage Offset Correction: v_off_ini = 0.000001459 V, v_off_fin = 0.000005572 V 23:33:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416330 Vs 23:33:15 Integrated Voltage Measurement... 23:33:54 Voltage Offset Correction: v_off_ini = 0.000003443 V, v_off_fin = -0.000001719 V 23:33:54 Integrated Voltage Measurement Delta Gap = -0.0040015 m VT = -0.175318016 Vs 23:33:57 Temperature Measurement, Probe Number = 0, T = 19.949000 C 23:33:57 Temperature Measurement, Probe Number = 1, T = 20.021000 C 23:33:58 Temperature Measurement, Probe Number = 2, T = 19.990000 C 23:33:58 Temperature Measurement, Probe Number = 3, T = 19.979000 C 23:33:58 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 23:33:59 Integrated Voltage Measurement... 23:34:18 Voltage Offset Correction: v_off_ini = 0.000003172 V, v_off_fin = 0.000005799 V 23:34:18 Integrated Voltage Measurement Delta Gap = 0.0040018 m VT = 0.175441021 Vs 23:34:18 Integrated Voltage Measurement... 23:34:38 Voltage Offset Correction: v_off_ini = 0.000005172 V, v_off_fin = -0.000001885 V 23:34:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298545 Vs 00:04:40 Temperature Measurement, Probe Number = 0, T = 20.088000 C 00:04:41 Temperature Measurement, Probe Number = 1, T = 20.017000 C 00:04:42 Temperature Measurement, Probe Number = 2, T = 19.984000 C 00:04:43 Temperature Measurement, Probe Number = 3, T = 19.977000 C 00:04:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 00:04:43 Integrated Voltage Measurement... 00:05:02 Voltage Offset Correction: v_off_ini = 0.000003493 V, v_off_fin = 0.000005875 V 00:05:02 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175507284 Vs 00:05:03 Integrated Voltage Measurement... 00:05:22 Voltage Offset Correction: v_off_ini = 0.000005472 V, v_off_fin = -0.000002515 V 00:05:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291403 Vs 00:05:24 Temperature Measurement, Probe Number = 0, T = 20.051000 C 00:05:25 Temperature Measurement, Probe Number = 1, T = 20.015000 C 00:05:26 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:05:26 Temperature Measurement, Probe Number = 3, T = 19.975000 C 00:05:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 00:05:27 Integrated Voltage Measurement... 00:05:46 Voltage Offset Correction: v_off_ini = 0.000001118 V, v_off_fin = 0.000005712 V 00:05:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411747 Vs 00:05:46 Integrated Voltage Measurement... 00:06:05 Voltage Offset Correction: v_off_ini = 0.000004667 V, v_off_fin = -0.000002543 V 00:06:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307482 Vs 00:06:08 Temperature Measurement, Probe Number = 0, T = 20.026000 C 00:06:09 Temperature Measurement, Probe Number = 1, T = 20.014000 C 00:06:10 Temperature Measurement, Probe Number = 2, T = 19.982000 C 00:06:10 Temperature Measurement, Probe Number = 3, T = 19.974000 C 00:06:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:06:10 Integrated Voltage Measurement... 00:06:30 Voltage Offset Correction: v_off_ini = 0.000001117 V, v_off_fin = 0.000005686 V 00:06:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422256 Vs 00:06:30 Integrated Voltage Measurement... 00:06:49 Voltage Offset Correction: v_off_ini = 0.000004742 V, v_off_fin = -0.000002361 V 00:06:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307541 Vs 00:06:52 Temperature Measurement, Probe Number = 0, T = 19.963000 C 00:06:53 Temperature Measurement, Probe Number = 1, T = 20.013000 C 00:06:53 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:06:54 Temperature Measurement, Probe Number = 3, T = 19.973000 C 00:06:54 Magnet Test Parameter Measurements P0 = Room, Value = 19.96 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:06:54 Integrated Voltage Measurement... 00:07:14 Voltage Offset Correction: v_off_ini = 0.000001808 V, v_off_fin = 0.000005771 V 00:07:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425699 Vs 00:07:14 Integrated Voltage Measurement... 00:07:33 Voltage Offset Correction: v_off_ini = 0.000005178 V, v_off_fin = -0.000002720 V 00:07:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298110 Vs 00:07:36 Temperature Measurement, Probe Number = 0, T = 19.954000 C 00:07:37 Temperature Measurement, Probe Number = 1, T = 20.015000 C 00:07:37 Temperature Measurement, Probe Number = 2, T = 19.986000 C 00:07:38 Temperature Measurement, Probe Number = 3, T = 19.974000 C 00:07:38 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 00:07:38 Integrated Voltage Measurement... 00:07:57 Voltage Offset Correction: v_off_ini = 0.000000850 V, v_off_fin = 0.000005781 V 00:07:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423618 Vs 00:07:57 Integrated Voltage Measurement... 00:08:17 Voltage Offset Correction: v_off_ini = 0.000004915 V, v_off_fin = -0.000002082 V 00:08:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306562 Vs 00:08:19 Temperature Measurement, Probe Number = 0, T = 20.024000 C 00:08:20 Temperature Measurement, Probe Number = 1, T = 20.016000 C 00:08:21 Temperature Measurement, Probe Number = 2, T = 19.986000 C 00:08:21 Temperature Measurement, Probe Number = 3, T = 19.975000 C 00:08:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.02 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:08:22 Integrated Voltage Measurement... 00:08:41 Voltage Offset Correction: v_off_ini = 0.000001238 V, v_off_fin = 0.000005540 V 00:08:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419557 Vs 00:08:41 Integrated Voltage Measurement... 00:09:00 Voltage Offset Correction: v_off_ini = 0.000004849 V, v_off_fin = -0.000002500 V 00:09:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303908 Vs 00:09:03 Temperature Measurement, Probe Number = 0, T = 20.090000 C 00:09:04 Temperature Measurement, Probe Number = 1, T = 20.015000 C 00:09:04 Temperature Measurement, Probe Number = 2, T = 19.987000 C 00:09:05 Temperature Measurement, Probe Number = 3, T = 19.976000 C 00:09:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:09:05 Integrated Voltage Measurement... 00:09:25 Voltage Offset Correction: v_off_ini = 0.000001493 V, v_off_fin = 0.000005391 V 00:09:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427794 Vs 00:09:25 Integrated Voltage Measurement... 00:09:44 Voltage Offset Correction: v_off_ini = 0.000004953 V, v_off_fin = -0.000002661 V 00:09:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302711 Vs 00:09:47 Temperature Measurement, Probe Number = 0, T = 20.120000 C 00:09:47 Temperature Measurement, Probe Number = 1, T = 20.016000 C 00:09:48 Temperature Measurement, Probe Number = 2, T = 19.988000 C 00:09:49 Temperature Measurement, Probe Number = 3, T = 19.977000 C 00:09:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:09:49 Integrated Voltage Measurement... 00:10:08 Voltage Offset Correction: v_off_ini = 0.000001240 V, v_off_fin = 0.000005624 V 00:10:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430868 Vs 00:10:08 Integrated Voltage Measurement... 00:10:28 Voltage Offset Correction: v_off_ini = 0.000005028 V, v_off_fin = -0.000001765 V 00:10:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313245 Vs 00:10:31 Temperature Measurement, Probe Number = 0, T = 20.128000 C 00:10:31 Temperature Measurement, Probe Number = 1, T = 20.017000 C 00:10:32 Temperature Measurement, Probe Number = 2, T = 19.987000 C 00:10:33 Temperature Measurement, Probe Number = 3, T = 19.976000 C 00:10:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 00:10:33 Integrated Voltage Measurement... 00:10:53 Voltage Offset Correction: v_off_ini = 0.000001229 V, v_off_fin = 0.000005844 V 00:10:53 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175422848 Vs 00:10:53 Integrated Voltage Measurement... 00:11:12 Voltage Offset Correction: v_off_ini = 0.000004887 V, v_off_fin = -0.000002199 V 00:11:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175294845 Vs 00:11:15 Temperature Measurement, Probe Number = 0, T = 20.047000 C 00:11:16 Temperature Measurement, Probe Number = 1, T = 20.015000 C 00:11:16 Temperature Measurement, Probe Number = 2, T = 19.983000 C 00:11:17 Temperature Measurement, Probe Number = 3, T = 19.974000 C 00:11:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:11:17 Integrated Voltage Measurement... 00:11:37 Voltage Offset Correction: v_off_ini = 0.000001230 V, v_off_fin = 0.000005693 V 00:11:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432852 Vs 00:11:37 Integrated Voltage Measurement... 00:11:56 Voltage Offset Correction: v_off_ini = 0.000004709 V, v_off_fin = -0.000002284 V 00:11:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300818 Vs 00:41:59 Temperature Measurement, Probe Number = 0, T = 19.975000 C 00:42:00 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:42:01 Temperature Measurement, Probe Number = 2, T = 19.976000 C 00:42:01 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:42:01 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:42:01 Integrated Voltage Measurement... 00:42:21 Voltage Offset Correction: v_off_ini = 0.000003317 V, v_off_fin = 0.000005523 V 00:42:21 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175512409 Vs 00:42:21 Integrated Voltage Measurement... 00:42:41 Voltage Offset Correction: v_off_ini = 0.000004971 V, v_off_fin = -0.000001712 V 00:42:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308642 Vs 00:42:44 Temperature Measurement, Probe Number = 0, T = 19.976000 C 00:42:44 Temperature Measurement, Probe Number = 1, T = 20.007000 C 00:42:45 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:42:45 Temperature Measurement, Probe Number = 3, T = 19.969000 C 00:42:46 Magnet Test Parameter Measurements P0 = Room, Value = 19.98 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:42:46 Integrated Voltage Measurement... 00:43:05 Voltage Offset Correction: v_off_ini = 0.000001477 V, v_off_fin = 0.000006144 V 00:43:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428463 Vs 00:43:05 Integrated Voltage Measurement... 00:43:24 Voltage Offset Correction: v_off_ini = 0.000004965 V, v_off_fin = -0.000002805 V 00:43:24 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175300544 Vs 00:43:27 Temperature Measurement, Probe Number = 0, T = 19.947000 C 00:43:28 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:43:28 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:43:29 Temperature Measurement, Probe Number = 3, T = 19.971000 C 00:43:29 Magnet Test Parameter Measurements P0 = Room, Value = 19.95 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:43:29 Integrated Voltage Measurement... 00:43:48 Voltage Offset Correction: v_off_ini = 0.000001399 V, v_off_fin = 0.000006368 V 00:43:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433557 Vs 00:43:49 Integrated Voltage Measurement... 00:44:08 Voltage Offset Correction: v_off_ini = 0.000005083 V, v_off_fin = -0.000002140 V 00:44:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301412 Vs 00:44:11 Temperature Measurement, Probe Number = 0, T = 19.931000 C 00:44:12 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:44:12 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:44:13 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:44:13 Magnet Test Parameter Measurements P0 = Room, Value = 19.93 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:44:13 Integrated Voltage Measurement... 00:44:32 Voltage Offset Correction: v_off_ini = 0.000001095 V, v_off_fin = 0.000005973 V 00:44:32 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422655 Vs 00:44:32 Integrated Voltage Measurement... 00:44:52 Voltage Offset Correction: v_off_ini = 0.000005327 V, v_off_fin = -0.000001748 V 00:44:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303228 Vs 00:44:55 Temperature Measurement, Probe Number = 0, T = 19.932000 C 00:44:55 Temperature Measurement, Probe Number = 1, T = 20.007000 C 00:44:56 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:44:57 Temperature Measurement, Probe Number = 3, T = 19.970000 C 00:44:57 Magnet Test Parameter Measurements P0 = Room, Value = 19.93 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:44:57 Integrated Voltage Measurement... 00:45:16 Voltage Offset Correction: v_off_ini = 0.000000906 V, v_off_fin = 0.000005260 V 00:45:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413549 Vs 00:45:17 Integrated Voltage Measurement... 00:45:37 Voltage Offset Correction: v_off_ini = 0.000004635 V, v_off_fin = -0.000002342 V 00:45:37 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309832 Vs 00:45:40 Temperature Measurement, Probe Number = 0, T = 20.029000 C 00:45:40 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:45:41 Temperature Measurement, Probe Number = 2, T = 19.980000 C 00:45:42 Temperature Measurement, Probe Number = 3, T = 19.972000 C 00:45:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.03 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:45:42 Integrated Voltage Measurement... 00:46:11 Voltage Offset Correction: v_off_ini = 0.000001138 V, v_off_fin = 0.000005559 V 00:46:12 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175414383 Vs 00:46:12 Integrated Voltage Measurement... 00:46:36 Voltage Offset Correction: v_off_ini = 0.000003967 V, v_off_fin = -0.000002489 V 00:46:36 Integrated Voltage Measurement Delta Gap = -0.0040012 m VT = -0.175325529 Vs 00:46:38 Temperature Measurement, Probe Number = 0, T = 20.051000 C 00:46:39 Temperature Measurement, Probe Number = 1, T = 20.007000 C 00:46:40 Temperature Measurement, Probe Number = 2, T = 19.974000 C 00:46:40 Temperature Measurement, Probe Number = 3, T = 19.965000 C 00:46:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.05 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 00:46:41 Integrated Voltage Measurement... 00:47:01 Voltage Offset Correction: v_off_ini = 0.000002170 V, v_off_fin = 0.000005084 V 00:47:02 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175434543 Vs 00:47:02 Integrated Voltage Measurement... 00:47:21 Voltage Offset Correction: v_off_ini = 0.000004288 V, v_off_fin = -0.000001808 V 00:47:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310592 Vs 00:47:24 Temperature Measurement, Probe Number = 0, T = 20.138000 C 00:47:25 Temperature Measurement, Probe Number = 1, T = 20.007000 C 00:47:26 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:47:26 Temperature Measurement, Probe Number = 3, T = 19.967000 C 00:47:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:47:26 Integrated Voltage Measurement... 00:47:46 Voltage Offset Correction: v_off_ini = 0.000001618 V, v_off_fin = 0.000006018 V 00:47:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175424429 Vs 00:47:46 Integrated Voltage Measurement... 00:48:05 Voltage Offset Correction: v_off_ini = 0.000005042 V, v_off_fin = -0.000002420 V 00:48:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310964 Vs 00:48:08 Temperature Measurement, Probe Number = 0, T = 20.184000 C 00:48:09 Temperature Measurement, Probe Number = 1, T = 20.009000 C 00:48:09 Temperature Measurement, Probe Number = 2, T = 19.981000 C 00:48:10 Temperature Measurement, Probe Number = 3, T = 19.967000 C 00:48:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:48:10 Integrated Voltage Measurement... 00:48:30 Voltage Offset Correction: v_off_ini = 0.000001361 V, v_off_fin = 0.000006326 V 00:48:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426641 Vs 00:48:30 Integrated Voltage Measurement... 00:48:50 Voltage Offset Correction: v_off_ini = 0.000004958 V, v_off_fin = -0.000001714 V 00:48:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311260 Vs 00:48:53 Temperature Measurement, Probe Number = 0, T = 20.204000 C 00:48:53 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:48:54 Temperature Measurement, Probe Number = 2, T = 19.980000 C 00:48:55 Temperature Measurement, Probe Number = 3, T = 19.972000 C 00:48:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:48:55 Integrated Voltage Measurement... 00:49:14 Voltage Offset Correction: v_off_ini = 0.000001515 V, v_off_fin = 0.000006041 V 00:49:14 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175424257 Vs 00:49:15 Integrated Voltage Measurement... 00:49:34 Voltage Offset Correction: v_off_ini = 0.000005090 V, v_off_fin = -0.000002185 V 00:49:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300946 Vs 01:19:37 Temperature Measurement, Probe Number = 0, T = 20.297000 C 01:19:37 Temperature Measurement, Probe Number = 1, T = 20.010000 C 01:19:38 Temperature Measurement, Probe Number = 2, T = 19.976000 C 01:19:39 Temperature Measurement, Probe Number = 3, T = 19.968000 C 01:19:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:19:39 Integrated Voltage Measurement... 01:19:58 Voltage Offset Correction: v_off_ini = 0.000003620 V, v_off_fin = 0.000005586 V 01:19:58 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175527424 Vs 01:19:58 Integrated Voltage Measurement... 01:20:18 Voltage Offset Correction: v_off_ini = 0.000004966 V, v_off_fin = -0.000001725 V 01:20:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288741 Vs 01:20:20 Temperature Measurement, Probe Number = 0, T = 20.270000 C 01:20:21 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:20:22 Temperature Measurement, Probe Number = 2, T = 19.982000 C 01:20:22 Temperature Measurement, Probe Number = 3, T = 19.969000 C 01:20:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:20:23 Integrated Voltage Measurement... 01:20:42 Voltage Offset Correction: v_off_ini = 0.000002670 V, v_off_fin = 0.000007135 V 01:20:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431800 Vs 01:20:42 Integrated Voltage Measurement... 01:21:01 Voltage Offset Correction: v_off_ini = 0.000006139 V, v_off_fin = -0.000000642 V 01:21:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289627 Vs 01:21:04 Temperature Measurement, Probe Number = 0, T = 20.253000 C 01:21:05 Temperature Measurement, Probe Number = 1, T = 20.009000 C 01:21:05 Temperature Measurement, Probe Number = 2, T = 19.982000 C 01:21:06 Temperature Measurement, Probe Number = 3, T = 19.971000 C 01:21:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:21:06 Integrated Voltage Measurement... 01:21:25 Voltage Offset Correction: v_off_ini = 0.000001790 V, v_off_fin = 0.000005680 V 01:21:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425516 Vs 01:21:26 Integrated Voltage Measurement... 01:21:45 Voltage Offset Correction: v_off_ini = 0.000005222 V, v_off_fin = -0.000002020 V 01:21:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299358 Vs 01:21:48 Temperature Measurement, Probe Number = 0, T = 20.260000 C 01:21:48 Temperature Measurement, Probe Number = 1, T = 20.009000 C 01:21:49 Temperature Measurement, Probe Number = 2, T = 19.981000 C 01:21:50 Temperature Measurement, Probe Number = 3, T = 19.970000 C 01:21:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:21:50 Integrated Voltage Measurement... 01:22:09 Voltage Offset Correction: v_off_ini = 0.000000845 V, v_off_fin = 0.000006381 V 01:22:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427422 Vs 01:22:09 Integrated Voltage Measurement... 01:22:28 Voltage Offset Correction: v_off_ini = 0.000005319 V, v_off_fin = -0.000002173 V 01:22:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302648 Vs 01:22:31 Temperature Measurement, Probe Number = 0, T = 20.204000 C 01:22:32 Temperature Measurement, Probe Number = 1, T = 20.008000 C 01:22:32 Temperature Measurement, Probe Number = 2, T = 19.979000 C 01:22:33 Temperature Measurement, Probe Number = 3, T = 19.970000 C 01:22:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:22:33 Integrated Voltage Measurement... 01:22:53 Voltage Offset Correction: v_off_ini = 0.000001873 V, v_off_fin = 0.000005935 V 01:22:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420045 Vs 01:22:53 Integrated Voltage Measurement... 01:23:12 Voltage Offset Correction: v_off_ini = 0.000004968 V, v_off_fin = -0.000002834 V 01:23:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304623 Vs 01:23:15 Temperature Measurement, Probe Number = 0, T = 20.191000 C 01:23:16 Temperature Measurement, Probe Number = 1, T = 20.010000 C 01:23:17 Temperature Measurement, Probe Number = 2, T = 19.983000 C 01:23:17 Temperature Measurement, Probe Number = 3, T = 19.973000 C 01:23:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:23:18 Integrated Voltage Measurement... 01:23:37 Voltage Offset Correction: v_off_ini = 0.000001517 V, v_off_fin = 0.000005496 V 01:23:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418287 Vs 01:23:37 Integrated Voltage Measurement... 01:23:56 Voltage Offset Correction: v_off_ini = 0.000004930 V, v_off_fin = -0.000002152 V 01:23:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301580 Vs 01:23:59 Temperature Measurement, Probe Number = 0, T = 20.236000 C 01:24:00 Temperature Measurement, Probe Number = 1, T = 20.012000 C 01:24:01 Temperature Measurement, Probe Number = 2, T = 19.982000 C 01:24:01 Temperature Measurement, Probe Number = 3, T = 19.973000 C 01:24:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:24:02 Integrated Voltage Measurement... 01:24:21 Voltage Offset Correction: v_off_ini = 0.000001706 V, v_off_fin = 0.000005686 V 01:24:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421211 Vs 01:24:21 Integrated Voltage Measurement... 01:24:41 Voltage Offset Correction: v_off_ini = 0.000004800 V, v_off_fin = -0.000001961 V 01:24:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306345 Vs 01:24:43 Temperature Measurement, Probe Number = 0, T = 20.277000 C 01:24:44 Temperature Measurement, Probe Number = 1, T = 20.012000 C 01:24:45 Temperature Measurement, Probe Number = 2, T = 19.986000 C 01:24:45 Temperature Measurement, Probe Number = 3, T = 19.970000 C 01:24:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 01:24:46 Integrated Voltage Measurement... 01:25:06 Voltage Offset Correction: v_off_ini = 0.000001188 V, v_off_fin = 0.000005502 V 01:25:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421017 Vs 01:25:06 Integrated Voltage Measurement... 01:25:25 Voltage Offset Correction: v_off_ini = 0.000004969 V, v_off_fin = -0.000002014 V 01:25:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298848 Vs 01:25:28 Temperature Measurement, Probe Number = 0, T = 20.233000 C 01:25:29 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:25:29 Temperature Measurement, Probe Number = 2, T = 19.983000 C 01:25:30 Temperature Measurement, Probe Number = 3, T = 19.970000 C 01:25:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:25:30 Integrated Voltage Measurement... 01:25:49 Voltage Offset Correction: v_off_ini = 0.000001562 V, v_off_fin = 0.000005998 V 01:25:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422068 Vs 01:25:49 Integrated Voltage Measurement... 01:26:09 Voltage Offset Correction: v_off_ini = 0.000005350 V, v_off_fin = -0.000001647 V 01:26:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311412 Vs 01:26:12 Temperature Measurement, Probe Number = 0, T = 20.260000 C 01:26:12 Temperature Measurement, Probe Number = 1, T = 20.011000 C 01:26:13 Temperature Measurement, Probe Number = 2, T = 19.981000 C 01:26:14 Temperature Measurement, Probe Number = 3, T = 19.968000 C 01:26:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:26:14 Integrated Voltage Measurement... 01:26:33 Voltage Offset Correction: v_off_ini = 0.000001516 V, v_off_fin = 0.000005942 V 01:26:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425238 Vs 01:26:33 Integrated Voltage Measurement... 01:26:52 Voltage Offset Correction: v_off_ini = 0.000005414 V, v_off_fin = -0.000002554 V 01:26:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175299978 Vs 01:56:55 Temperature Measurement, Probe Number = 0, T = 20.099000 C 01:56:56 Temperature Measurement, Probe Number = 1, T = 20.001000 C 01:56:56 Temperature Measurement, Probe Number = 2, T = 19.969000 C 01:56:57 Temperature Measurement, Probe Number = 3, T = 19.962000 C 01:56:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:56:57 Integrated Voltage Measurement... 01:57:17 Voltage Offset Correction: v_off_ini = 0.000003584 V, v_off_fin = 0.000005712 V 01:57:17 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175523431 Vs 01:57:17 Integrated Voltage Measurement... 01:57:36 Voltage Offset Correction: v_off_ini = 0.000004618 V, v_off_fin = -0.000002306 V 01:57:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295791 Vs 01:57:39 Temperature Measurement, Probe Number = 0, T = 20.122000 C 01:57:40 Temperature Measurement, Probe Number = 1, T = 20.003000 C 01:57:40 Temperature Measurement, Probe Number = 2, T = 19.974000 C 01:57:41 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:57:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:57:41 Integrated Voltage Measurement... 01:58:00 Voltage Offset Correction: v_off_ini = 0.000001311 V, v_off_fin = 0.000005295 V 01:58:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414400 Vs 01:58:00 Integrated Voltage Measurement... 01:58:20 Voltage Offset Correction: v_off_ini = 0.000004939 V, v_off_fin = -0.000002679 V 01:58:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301969 Vs 01:58:23 Temperature Measurement, Probe Number = 0, T = 20.158000 C 01:58:23 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:58:24 Temperature Measurement, Probe Number = 2, T = 19.978000 C 01:58:25 Temperature Measurement, Probe Number = 3, T = 19.968000 C 01:58:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:58:25 Integrated Voltage Measurement... 01:58:44 Voltage Offset Correction: v_off_ini = 0.000001091 V, v_off_fin = 0.000005674 V 01:58:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414167 Vs 01:58:44 Integrated Voltage Measurement... 01:59:04 Voltage Offset Correction: v_off_ini = 0.000004992 V, v_off_fin = -0.000002313 V 01:59:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306309 Vs 01:59:07 Temperature Measurement, Probe Number = 0, T = 20.152000 C 01:59:07 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:59:08 Temperature Measurement, Probe Number = 2, T = 19.979000 C 01:59:09 Temperature Measurement, Probe Number = 3, T = 19.967000 C 01:59:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:59:09 Integrated Voltage Measurement... 01:59:28 Voltage Offset Correction: v_off_ini = 0.000001420 V, v_off_fin = 0.000005934 V 01:59:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419938 Vs 01:59:28 Integrated Voltage Measurement... 01:59:48 Voltage Offset Correction: v_off_ini = 0.000005155 V, v_off_fin = -0.000001604 V 01:59:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298776 Vs 01:59:51 Temperature Measurement, Probe Number = 0, T = 20.143000 C 01:59:52 Temperature Measurement, Probe Number = 1, T = 20.003000 C 01:59:52 Temperature Measurement, Probe Number = 2, T = 19.973000 C 01:59:53 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:59:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:59:53 Integrated Voltage Measurement... 02:00:13 Voltage Offset Correction: v_off_ini = 0.000001373 V, v_off_fin = 0.000005366 V 02:00:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175412263 Vs 02:00:13 Integrated Voltage Measurement... 02:00:32 Voltage Offset Correction: v_off_ini = 0.000004592 V, v_off_fin = -0.000002446 V 02:00:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299380 Vs 02:00:35 Temperature Measurement, Probe Number = 0, T = 20.141000 C 02:00:36 Temperature Measurement, Probe Number = 1, T = 20.006000 C 02:00:36 Temperature Measurement, Probe Number = 2, T = 19.976000 C 02:00:37 Temperature Measurement, Probe Number = 3, T = 19.970000 C 02:00:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 02:00:37 Integrated Voltage Measurement... 02:00:56 Voltage Offset Correction: v_off_ini = 0.000001396 V, v_off_fin = 0.000005594 V 02:00:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421513 Vs 02:00:57 Integrated Voltage Measurement... 02:01:16 Voltage Offset Correction: v_off_ini = 0.000004850 V, v_off_fin = -0.000002234 V 02:01:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304035 Vs 02:01:19 Temperature Measurement, Probe Number = 0, T = 20.185000 C 02:01:20 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:01:20 Temperature Measurement, Probe Number = 2, T = 19.972000 C 02:01:21 Temperature Measurement, Probe Number = 3, T = 19.965000 C 02:01:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:01:21 Integrated Voltage Measurement... 02:01:40 Voltage Offset Correction: v_off_ini = 0.000001240 V, v_off_fin = 0.000005386 V 02:01:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413383 Vs 02:01:41 Integrated Voltage Measurement... 02:02:00 Voltage Offset Correction: v_off_ini = 0.000004677 V, v_off_fin = -0.000002045 V 02:02:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305080 Vs 02:02:03 Temperature Measurement, Probe Number = 0, T = 20.171000 C 02:02:04 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:02:04 Temperature Measurement, Probe Number = 2, T = 19.969000 C 02:02:05 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:02:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:02:05 Integrated Voltage Measurement... 02:02:24 Voltage Offset Correction: v_off_ini = 0.000000974 V, v_off_fin = 0.000005599 V 02:02:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420096 Vs 02:02:25 Integrated Voltage Measurement... 02:02:44 Voltage Offset Correction: v_off_ini = 0.000005052 V, v_off_fin = -0.000002017 V 02:02:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302869 Vs 02:02:47 Temperature Measurement, Probe Number = 0, T = 20.154000 C 02:02:48 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:02:48 Temperature Measurement, Probe Number = 2, T = 19.970000 C 02:02:49 Temperature Measurement, Probe Number = 3, T = 19.962000 C 02:02:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:02:49 Integrated Voltage Measurement... 02:03:08 Voltage Offset Correction: v_off_ini = 0.000001460 V, v_off_fin = 0.000005424 V 02:03:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419199 Vs 02:03:09 Integrated Voltage Measurement... 02:03:28 Voltage Offset Correction: v_off_ini = 0.000004780 V, v_off_fin = -0.000002323 V 02:03:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300817 Vs 02:03:30 Temperature Measurement, Probe Number = 0, T = 20.176000 C 02:03:31 Temperature Measurement, Probe Number = 1, T = 20.002000 C 02:03:32 Temperature Measurement, Probe Number = 2, T = 19.971000 C 02:03:32 Temperature Measurement, Probe Number = 3, T = 19.964000 C 02:03:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:03:33 Integrated Voltage Measurement... 02:03:52 Voltage Offset Correction: v_off_ini = 0.000001181 V, v_off_fin = 0.000005608 V 02:03:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421124 Vs 02:03:53 Integrated Voltage Measurement... 02:04:12 Voltage Offset Correction: v_off_ini = 0.000004882 V, v_off_fin = -0.000002229 V 02:04:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307772 Vs 02:34:15 Temperature Measurement, Probe Number = 0, T = 20.183000 C 02:34:16 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:34:17 Temperature Measurement, Probe Number = 2, T = 19.966000 C 02:34:17 Temperature Measurement, Probe Number = 3, T = 19.957000 C 02:34:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:34:18 Integrated Voltage Measurement... 02:34:37 Voltage Offset Correction: v_off_ini = 0.000003770 V, v_off_fin = 0.000005452 V 02:34:38 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175513199 Vs 02:34:38 Integrated Voltage Measurement... 02:34:57 Voltage Offset Correction: v_off_ini = 0.000004909 V, v_off_fin = -0.000002003 V 02:34:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303503 Vs 02:35:00 Temperature Measurement, Probe Number = 0, T = 20.201000 C 02:35:01 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:35:01 Temperature Measurement, Probe Number = 2, T = 19.970000 C 02:35:02 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:35:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:35:02 Integrated Voltage Measurement... 02:35:21 Voltage Offset Correction: v_off_ini = 0.000001437 V, v_off_fin = 0.000006212 V 02:35:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421643 Vs 02:35:22 Integrated Voltage Measurement... 02:35:41 Voltage Offset Correction: v_off_ini = 0.000005525 V, v_off_fin = -0.000001780 V 02:35:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294143 Vs 02:35:44 Temperature Measurement, Probe Number = 0, T = 20.227000 C 02:35:44 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:35:45 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:35:46 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:35:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:35:46 Integrated Voltage Measurement... 02:36:05 Voltage Offset Correction: v_off_ini = 0.000001109 V, v_off_fin = 0.000005585 V 02:36:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425284 Vs 02:36:06 Integrated Voltage Measurement... 02:36:25 Voltage Offset Correction: v_off_ini = 0.000005012 V, v_off_fin = -0.000002110 V 02:36:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296256 Vs 02:36:28 Temperature Measurement, Probe Number = 0, T = 20.283000 C 02:36:28 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:36:29 Temperature Measurement, Probe Number = 2, T = 19.974000 C 02:36:30 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:36:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:36:30 Integrated Voltage Measurement... 02:36:49 Voltage Offset Correction: v_off_ini = 0.000002047 V, v_off_fin = 0.000006386 V 02:36:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425715 Vs 02:36:49 Integrated Voltage Measurement... 02:37:08 Voltage Offset Correction: v_off_ini = 0.000005331 V, v_off_fin = -0.000002197 V 02:37:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300183 Vs 02:37:11 Temperature Measurement, Probe Number = 0, T = 20.252000 C 02:37:12 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:37:12 Temperature Measurement, Probe Number = 2, T = 19.976000 C 02:37:13 Temperature Measurement, Probe Number = 3, T = 19.964000 C 02:37:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:37:13 Integrated Voltage Measurement... 02:37:33 Voltage Offset Correction: v_off_ini = 0.000001654 V, v_off_fin = 0.000005154 V 02:37:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418690 Vs 02:37:33 Integrated Voltage Measurement... 02:37:52 Voltage Offset Correction: v_off_ini = 0.000004590 V, v_off_fin = -0.000002771 V 02:37:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308304 Vs 02:37:55 Temperature Measurement, Probe Number = 0, T = 20.272000 C 02:37:56 Temperature Measurement, Probe Number = 1, T = 20.002000 C 02:37:57 Temperature Measurement, Probe Number = 2, T = 19.972000 C 02:37:57 Temperature Measurement, Probe Number = 3, T = 19.962000 C 02:37:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:37:57 Integrated Voltage Measurement... 02:38:17 Voltage Offset Correction: v_off_ini = 0.000000960 V, v_off_fin = 0.000005700 V 02:38:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420403 Vs 02:38:17 Integrated Voltage Measurement... 02:38:36 Voltage Offset Correction: v_off_ini = 0.000005033 V, v_off_fin = -0.000002059 V 02:38:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305779 Vs 02:38:39 Temperature Measurement, Probe Number = 0, T = 20.246000 C 02:38:40 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:38:41 Temperature Measurement, Probe Number = 2, T = 19.971000 C 02:38:41 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:38:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:38:41 Integrated Voltage Measurement... 02:39:01 Voltage Offset Correction: v_off_ini = 0.000001466 V, v_off_fin = 0.000006877 V 02:39:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429642 Vs 02:39:01 Integrated Voltage Measurement... 02:39:20 Voltage Offset Correction: v_off_ini = 0.000005836 V, v_off_fin = -0.000001832 V 02:39:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302595 Vs 02:39:23 Temperature Measurement, Probe Number = 0, T = 20.258000 C 02:39:24 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:39:25 Temperature Measurement, Probe Number = 2, T = 19.969000 C 02:39:25 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:39:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:39:26 Integrated Voltage Measurement... 02:39:45 Voltage Offset Correction: v_off_ini = 0.000001765 V, v_off_fin = 0.000006258 V 02:39:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175426027 Vs 02:39:45 Integrated Voltage Measurement... 02:40:05 Voltage Offset Correction: v_off_ini = 0.000005361 V, v_off_fin = -0.000001666 V 02:40:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304076 Vs 02:40:07 Temperature Measurement, Probe Number = 0, T = 20.238000 C 02:40:08 Temperature Measurement, Probe Number = 1, T = 20.000000 C 02:40:09 Temperature Measurement, Probe Number = 2, T = 19.966000 C 02:40:09 Temperature Measurement, Probe Number = 3, T = 19.960000 C 02:40:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:40:10 Integrated Voltage Measurement... 02:40:29 Voltage Offset Correction: v_off_ini = 0.000001658 V, v_off_fin = 0.000005858 V 02:40:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424938 Vs 02:40:29 Integrated Voltage Measurement... 02:40:49 Voltage Offset Correction: v_off_ini = 0.000004996 V, v_off_fin = -0.000001716 V 02:40:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302892 Vs 02:40:52 Temperature Measurement, Probe Number = 0, T = 20.207000 C 02:40:52 Temperature Measurement, Probe Number = 1, T = 20.002000 C 02:40:53 Temperature Measurement, Probe Number = 2, T = 19.967000 C 02:40:54 Temperature Measurement, Probe Number = 3, T = 19.960000 C 02:40:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:40:54 Integrated Voltage Measurement... 02:41:13 Voltage Offset Correction: v_off_ini = 0.000001853 V, v_off_fin = 0.000005693 V 02:41:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420939 Vs 02:41:13 Integrated Voltage Measurement... 02:41:33 Voltage Offset Correction: v_off_ini = 0.000004874 V, v_off_fin = -0.000002272 V 02:41:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303422 Vs 03:11:36 Temperature Measurement, Probe Number = 0, T = 20.268000 C 03:11:36 Temperature Measurement, Probe Number = 1, T = 19.998000 C 03:11:37 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:11:38 Temperature Measurement, Probe Number = 3, T = 19.961000 C 03:11:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:11:38 Integrated Voltage Measurement... 03:11:57 Voltage Offset Correction: v_off_ini = 0.000003088 V, v_off_fin = 0.000006006 V 03:11:57 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175507124 Vs 03:11:57 Integrated Voltage Measurement... 03:12:16 Voltage Offset Correction: v_off_ini = 0.000005198 V, v_off_fin = -0.000001740 V 03:12:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291540 Vs 03:12:19 Temperature Measurement, Probe Number = 0, T = 20.276000 C 03:12:20 Temperature Measurement, Probe Number = 1, T = 19.999000 C 03:12:21 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:12:21 Temperature Measurement, Probe Number = 3, T = 19.961000 C 03:12:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:12:21 Integrated Voltage Measurement... 03:12:41 Voltage Offset Correction: v_off_ini = 0.000001476 V, v_off_fin = 0.000005562 V 03:12:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415068 Vs 03:12:41 Integrated Voltage Measurement... 03:13:00 Voltage Offset Correction: v_off_ini = 0.000005104 V, v_off_fin = -0.000002049 V 03:13:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301981 Vs 03:13:03 Temperature Measurement, Probe Number = 0, T = 20.293000 C 03:13:03 Temperature Measurement, Probe Number = 1, T = 20.001000 C 03:13:04 Temperature Measurement, Probe Number = 2, T = 19.970000 C 03:13:05 Temperature Measurement, Probe Number = 3, T = 19.959000 C 03:13:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:13:05 Integrated Voltage Measurement... 03:13:24 Voltage Offset Correction: v_off_ini = 0.000001291 V, v_off_fin = 0.000006043 V 03:13:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423335 Vs 03:13:24 Integrated Voltage Measurement... 03:13:44 Voltage Offset Correction: v_off_ini = 0.000005289 V, v_off_fin = -0.000001565 V 03:13:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299204 Vs 03:13:47 Temperature Measurement, Probe Number = 0, T = 20.275000 C 03:13:48 Temperature Measurement, Probe Number = 1, T = 20.000000 C 03:13:48 Temperature Measurement, Probe Number = 2, T = 19.971000 C 03:13:49 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:13:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:13:49 Integrated Voltage Measurement... 03:14:08 Voltage Offset Correction: v_off_ini = 0.000000920 V, v_off_fin = 0.000005774 V 03:14:08 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175409681 Vs 03:14:08 Integrated Voltage Measurement... 03:14:28 Voltage Offset Correction: v_off_ini = 0.000004797 V, v_off_fin = -0.000002144 V 03:14:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299582 Vs 03:14:31 Temperature Measurement, Probe Number = 0, T = 20.260000 C 03:14:31 Temperature Measurement, Probe Number = 1, T = 20.003000 C 03:14:32 Temperature Measurement, Probe Number = 2, T = 19.974000 C 03:14:33 Temperature Measurement, Probe Number = 3, T = 19.961000 C 03:14:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:14:33 Integrated Voltage Measurement... 03:14:52 Voltage Offset Correction: v_off_ini = 0.000001411 V, v_off_fin = 0.000005412 V 03:14:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418127 Vs 03:14:52 Integrated Voltage Measurement... 03:15:12 Voltage Offset Correction: v_off_ini = 0.000005055 V, v_off_fin = -0.000002424 V 03:15:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302742 Vs 03:15:15 Temperature Measurement, Probe Number = 0, T = 20.264000 C 03:15:16 Temperature Measurement, Probe Number = 1, T = 20.003000 C 03:15:16 Temperature Measurement, Probe Number = 2, T = 19.968000 C 03:15:17 Temperature Measurement, Probe Number = 3, T = 19.960000 C 03:15:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:15:17 Integrated Voltage Measurement... 03:15:36 Voltage Offset Correction: v_off_ini = 0.000001361 V, v_off_fin = 0.000005317 V 03:15:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416714 Vs 03:15:36 Integrated Voltage Measurement... 03:15:56 Voltage Offset Correction: v_off_ini = 0.000004678 V, v_off_fin = -0.000002725 V 03:15:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309041 Vs 03:15:59 Temperature Measurement, Probe Number = 0, T = 20.211000 C 03:15:59 Temperature Measurement, Probe Number = 1, T = 19.999000 C 03:16:00 Temperature Measurement, Probe Number = 2, T = 19.966000 C 03:16:01 Temperature Measurement, Probe Number = 3, T = 19.957000 C 03:16:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:16:01 Integrated Voltage Measurement... 03:16:20 Voltage Offset Correction: v_off_ini = 0.000000795 V, v_off_fin = 0.000005475 V 03:16:20 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175412030 Vs 03:16:21 Integrated Voltage Measurement... 03:16:40 Voltage Offset Correction: v_off_ini = 0.000004909 V, v_off_fin = -0.000002309 V 03:16:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303281 Vs 03:16:43 Temperature Measurement, Probe Number = 0, T = 20.186000 C 03:16:44 Temperature Measurement, Probe Number = 1, T = 19.995000 C 03:16:44 Temperature Measurement, Probe Number = 2, T = 19.968000 C 03:16:45 Temperature Measurement, Probe Number = 3, T = 19.960000 C 03:16:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:16:45 Integrated Voltage Measurement... 03:17:04 Voltage Offset Correction: v_off_ini = 0.000001521 V, v_off_fin = 0.000005872 V 03:17:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420435 Vs 03:17:05 Integrated Voltage Measurement... 03:17:24 Voltage Offset Correction: v_off_ini = 0.000004759 V, v_off_fin = -0.000002676 V 03:17:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301222 Vs 03:17:27 Temperature Measurement, Probe Number = 0, T = 20.236000 C 03:17:28 Temperature Measurement, Probe Number = 1, T = 20.000000 C 03:17:28 Temperature Measurement, Probe Number = 2, T = 19.969000 C 03:17:29 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:17:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:17:29 Integrated Voltage Measurement... 03:17:48 Voltage Offset Correction: v_off_ini = 0.000001254 V, v_off_fin = 0.000005569 V 03:17:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417124 Vs 03:17:48 Integrated Voltage Measurement... 03:18:07 Voltage Offset Correction: v_off_ini = 0.000004784 V, v_off_fin = -0.000002381 V 03:18:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302338 Vs 03:18:10 Temperature Measurement, Probe Number = 0, T = 20.297000 C 03:18:11 Temperature Measurement, Probe Number = 1, T = 19.998000 C 03:18:12 Temperature Measurement, Probe Number = 2, T = 19.971000 C 03:18:12 Temperature Measurement, Probe Number = 3, T = 19.962000 C 03:18:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:18:12 Integrated Voltage Measurement... 03:18:31 Voltage Offset Correction: v_off_ini = 0.000001068 V, v_off_fin = 0.000005598 V 03:18:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421936 Vs 03:18:32 Integrated Voltage Measurement... 03:18:51 Voltage Offset Correction: v_off_ini = 0.000004832 V, v_off_fin = -0.000002651 V 03:18:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307825 Vs 03:48:54 Temperature Measurement, Probe Number = 0, T = 20.248000 C 03:48:55 Temperature Measurement, Probe Number = 1, T = 19.992000 C 03:48:55 Temperature Measurement, Probe Number = 2, T = 19.958000 C 03:48:56 Temperature Measurement, Probe Number = 3, T = 19.950000 C 03:48:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:48:56 Integrated Voltage Measurement... 03:49:15 Voltage Offset Correction: v_off_ini = 0.000004133 V, v_off_fin = 0.000006036 V 03:49:16 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175510819 Vs 03:49:16 Integrated Voltage Measurement... 03:49:35 Voltage Offset Correction: v_off_ini = 0.000005271 V, v_off_fin = -0.000001767 V 03:49:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175296654 Vs 03:49:38 Temperature Measurement, Probe Number = 0, T = 20.265000 C 03:49:39 Temperature Measurement, Probe Number = 1, T = 19.992000 C 03:49:39 Temperature Measurement, Probe Number = 2, T = 19.963000 C 03:49:40 Temperature Measurement, Probe Number = 3, T = 19.955000 C 03:49:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:49:40 Integrated Voltage Measurement... 03:50:00 Voltage Offset Correction: v_off_ini = 0.000002179 V, v_off_fin = 0.000006171 V 03:50:00 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175419468 Vs 03:50:00 Integrated Voltage Measurement... 03:50:19 Voltage Offset Correction: v_off_ini = 0.000005281 V, v_off_fin = -0.000001110 V 03:50:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289930 Vs 03:50:22 Temperature Measurement, Probe Number = 0, T = 20.246000 C 03:50:23 Temperature Measurement, Probe Number = 1, T = 19.993000 C 03:50:24 Temperature Measurement, Probe Number = 2, T = 19.963000 C 03:50:24 Temperature Measurement, Probe Number = 3, T = 19.952000 C 03:50:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:50:24 Integrated Voltage Measurement... 03:50:43 Voltage Offset Correction: v_off_ini = 0.000001814 V, v_off_fin = 0.000006025 V 03:50:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425309 Vs 03:50:44 Integrated Voltage Measurement... 03:51:03 Voltage Offset Correction: v_off_ini = 0.000005619 V, v_off_fin = -0.000002267 V 03:51:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298700 Vs 03:51:06 Temperature Measurement, Probe Number = 0, T = 20.226000 C 03:51:07 Temperature Measurement, Probe Number = 1, T = 19.991000 C 03:51:07 Temperature Measurement, Probe Number = 2, T = 19.959000 C 03:51:08 Temperature Measurement, Probe Number = 3, T = 19.952000 C 03:51:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:51:08 Integrated Voltage Measurement... 03:51:28 Voltage Offset Correction: v_off_ini = 0.000001824 V, v_off_fin = 0.000006202 V 03:51:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423925 Vs 03:51:28 Integrated Voltage Measurement... 03:51:47 Voltage Offset Correction: v_off_ini = 0.000005417 V, v_off_fin = -0.000002215 V 03:51:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302585 Vs 03:51:50 Temperature Measurement, Probe Number = 0, T = 20.199000 C 03:51:51 Temperature Measurement, Probe Number = 1, T = 19.991000 C 03:51:52 Temperature Measurement, Probe Number = 2, T = 19.956000 C 03:51:52 Temperature Measurement, Probe Number = 3, T = 19.949000 C 03:51:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:51:53 Integrated Voltage Measurement... 03:52:12 Voltage Offset Correction: v_off_ini = 0.000001554 V, v_off_fin = 0.000006499 V 03:52:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431046 Vs 03:52:12 Integrated Voltage Measurement... 03:52:32 Voltage Offset Correction: v_off_ini = 0.000005586 V, v_off_fin = -0.000001855 V 03:52:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299409 Vs 03:52:34 Temperature Measurement, Probe Number = 0, T = 20.177000 C 03:52:35 Temperature Measurement, Probe Number = 1, T = 19.991000 C 03:52:36 Temperature Measurement, Probe Number = 2, T = 19.957000 C 03:52:36 Temperature Measurement, Probe Number = 3, T = 19.951000 C 03:52:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:52:37 Integrated Voltage Measurement... 03:52:56 Voltage Offset Correction: v_off_ini = 0.000001784 V, v_off_fin = 0.000006207 V 03:52:56 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425093 Vs 03:52:56 Integrated Voltage Measurement... 03:53:15 Voltage Offset Correction: v_off_ini = 0.000005353 V, v_off_fin = -0.000002126 V 03:53:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304813 Vs 03:53:18 Temperature Measurement, Probe Number = 0, T = 20.207000 C 03:53:19 Temperature Measurement, Probe Number = 1, T = 19.989000 C 03:53:19 Temperature Measurement, Probe Number = 2, T = 19.963000 C 03:53:20 Temperature Measurement, Probe Number = 3, T = 19.949000 C 03:53:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:53:20 Integrated Voltage Measurement... 03:53:40 Voltage Offset Correction: v_off_ini = 0.000001948 V, v_off_fin = 0.000005809 V 03:53:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430212 Vs 03:53:40 Integrated Voltage Measurement... 03:53:59 Voltage Offset Correction: v_off_ini = 0.000005012 V, v_off_fin = -0.000001086 V 03:54:00 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303749 Vs 03:54:02 Temperature Measurement, Probe Number = 0, T = 20.249000 C 03:54:03 Temperature Measurement, Probe Number = 1, T = 19.989000 C 03:54:04 Temperature Measurement, Probe Number = 2, T = 19.962000 C 03:54:04 Temperature Measurement, Probe Number = 3, T = 19.951000 C 03:54:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:54:04 Integrated Voltage Measurement... 03:54:24 Voltage Offset Correction: v_off_ini = 0.000001794 V, v_off_fin = 0.000006468 V 03:54:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429307 Vs 03:54:24 Integrated Voltage Measurement... 03:54:44 Voltage Offset Correction: v_off_ini = 0.000005782 V, v_off_fin = -0.000001554 V 03:54:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175299969 Vs 03:54:46 Temperature Measurement, Probe Number = 0, T = 20.227000 C 03:54:47 Temperature Measurement, Probe Number = 1, T = 19.988000 C 03:54:48 Temperature Measurement, Probe Number = 2, T = 19.960000 C 03:54:48 Temperature Measurement, Probe Number = 3, T = 19.951000 C 03:54:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:54:49 Integrated Voltage Measurement... 03:55:08 Voltage Offset Correction: v_off_ini = 0.000002575 V, v_off_fin = 0.000006211 V 03:55:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427702 Vs 03:55:08 Integrated Voltage Measurement... 03:55:28 Voltage Offset Correction: v_off_ini = 0.000005674 V, v_off_fin = -0.000001201 V 03:55:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299301 Vs 03:55:30 Temperature Measurement, Probe Number = 0, T = 20.174000 C 03:55:31 Temperature Measurement, Probe Number = 1, T = 19.989000 C 03:55:32 Temperature Measurement, Probe Number = 2, T = 19.957000 C 03:55:32 Temperature Measurement, Probe Number = 3, T = 19.949000 C 03:55:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:55:33 Integrated Voltage Measurement... 03:55:52 Voltage Offset Correction: v_off_ini = 0.000002216 V, v_off_fin = 0.000006532 V 03:55:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429566 Vs 03:55:52 Integrated Voltage Measurement... 03:56:12 Voltage Offset Correction: v_off_ini = 0.000005361 V, v_off_fin = -0.000000738 V 03:56:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312476 Vs 04:26:15 Temperature Measurement, Probe Number = 0, T = 20.161000 C 04:26:15 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:26:16 Temperature Measurement, Probe Number = 2, T = 19.950000 C 04:26:17 Temperature Measurement, Probe Number = 3, T = 19.944000 C 04:26:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 04:26:17 Integrated Voltage Measurement... 04:26:36 Voltage Offset Correction: v_off_ini = 0.000003471 V, v_off_fin = 0.000005766 V 04:26:36 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175502393 Vs 04:26:36 Integrated Voltage Measurement... 04:26:55 Voltage Offset Correction: v_off_ini = 0.000004848 V, v_off_fin = -0.000002101 V 04:26:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304314 Vs 04:26:58 Temperature Measurement, Probe Number = 0, T = 20.121000 C 04:26:59 Temperature Measurement, Probe Number = 1, T = 19.985000 C 04:27:00 Temperature Measurement, Probe Number = 2, T = 19.956000 C 04:27:00 Temperature Measurement, Probe Number = 3, T = 19.946000 C 04:27:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:27:01 Integrated Voltage Measurement... 04:27:20 Voltage Offset Correction: v_off_ini = 0.000001001 V, v_off_fin = 0.000005847 V 04:27:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427425 Vs 04:27:20 Integrated Voltage Measurement... 04:27:39 Voltage Offset Correction: v_off_ini = 0.000005060 V, v_off_fin = -0.000001822 V 04:27:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300673 Vs 04:27:42 Temperature Measurement, Probe Number = 0, T = 20.096000 C 04:27:43 Temperature Measurement, Probe Number = 1, T = 19.984000 C 04:27:44 Temperature Measurement, Probe Number = 2, T = 19.954000 C 04:27:44 Temperature Measurement, Probe Number = 3, T = 19.945000 C 04:27:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:27:45 Integrated Voltage Measurement... 04:28:04 Voltage Offset Correction: v_off_ini = 0.000001295 V, v_off_fin = 0.000005794 V 04:28:05 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175428873 Vs 04:28:05 Integrated Voltage Measurement... 04:28:24 Voltage Offset Correction: v_off_ini = 0.000004896 V, v_off_fin = -0.000001923 V 04:28:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305101 Vs 04:28:27 Temperature Measurement, Probe Number = 0, T = 20.071000 C 04:28:28 Temperature Measurement, Probe Number = 1, T = 19.982000 C 04:28:28 Temperature Measurement, Probe Number = 2, T = 19.951000 C 04:28:29 Temperature Measurement, Probe Number = 3, T = 19.943000 C 04:28:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 04:28:29 Integrated Voltage Measurement... 04:28:48 Voltage Offset Correction: v_off_ini = 0.000001450 V, v_off_fin = 0.000005732 V 04:28:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426400 Vs 04:28:49 Integrated Voltage Measurement... 04:29:08 Voltage Offset Correction: v_off_ini = 0.000005227 V, v_off_fin = -0.000002898 V 04:29:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314295 Vs 04:29:11 Temperature Measurement, Probe Number = 0, T = 20.075000 C 04:29:11 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:29:12 Temperature Measurement, Probe Number = 2, T = 19.951000 C 04:29:12 Temperature Measurement, Probe Number = 3, T = 19.945000 C 04:29:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:29:13 Integrated Voltage Measurement... 04:29:33 Voltage Offset Correction: v_off_ini = 0.000001767 V, v_off_fin = 0.000005611 V 04:29:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435369 Vs 04:29:33 Integrated Voltage Measurement... 04:29:52 Voltage Offset Correction: v_off_ini = 0.000004797 V, v_off_fin = -0.000002485 V 04:29:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307462 Vs 04:29:55 Temperature Measurement, Probe Number = 0, T = 20.148000 C 04:29:56 Temperature Measurement, Probe Number = 1, T = 19.984000 C 04:29:56 Temperature Measurement, Probe Number = 2, T = 19.956000 C 04:29:57 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:29:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:29:57 Integrated Voltage Measurement... 04:30:16 Voltage Offset Correction: v_off_ini = 0.000001881 V, v_off_fin = 0.000006029 V 04:30:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428688 Vs 04:30:16 Integrated Voltage Measurement... 04:30:36 Voltage Offset Correction: v_off_ini = 0.000004995 V, v_off_fin = -0.000001822 V 04:30:36 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175310876 Vs 04:30:39 Temperature Measurement, Probe Number = 0, T = 20.163000 C 04:30:39 Temperature Measurement, Probe Number = 1, T = 19.985000 C 04:30:40 Temperature Measurement, Probe Number = 2, T = 19.955000 C 04:30:41 Temperature Measurement, Probe Number = 3, T = 19.948000 C 04:30:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:30:41 Integrated Voltage Measurement... 04:31:00 Voltage Offset Correction: v_off_ini = 0.000001486 V, v_off_fin = 0.000005762 V 04:31:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422832 Vs 04:31:00 Integrated Voltage Measurement... 04:31:19 Voltage Offset Correction: v_off_ini = 0.000005231 V, v_off_fin = -0.000002679 V 04:31:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305225 Vs 04:31:22 Temperature Measurement, Probe Number = 0, T = 20.166000 C 04:31:23 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:31:24 Temperature Measurement, Probe Number = 2, T = 19.960000 C 04:31:24 Temperature Measurement, Probe Number = 3, T = 19.945000 C 04:31:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:31:24 Integrated Voltage Measurement... 04:31:44 Voltage Offset Correction: v_off_ini = 0.000001314 V, v_off_fin = 0.000006034 V 04:31:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436865 Vs 04:31:44 Integrated Voltage Measurement... 04:32:03 Voltage Offset Correction: v_off_ini = 0.000005123 V, v_off_fin = -0.000002180 V 04:32:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304254 Vs 04:32:06 Temperature Measurement, Probe Number = 0, T = 20.122000 C 04:32:07 Temperature Measurement, Probe Number = 1, T = 19.988000 C 04:32:08 Temperature Measurement, Probe Number = 2, T = 19.959000 C 04:32:08 Temperature Measurement, Probe Number = 3, T = 19.951000 C 04:32:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:32:08 Integrated Voltage Measurement... 04:32:28 Voltage Offset Correction: v_off_ini = 0.000001152 V, v_off_fin = 0.000005847 V 04:32:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430931 Vs 04:32:28 Integrated Voltage Measurement... 04:32:47 Voltage Offset Correction: v_off_ini = 0.000005157 V, v_off_fin = -0.000002348 V 04:32:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314780 Vs 04:32:50 Temperature Measurement, Probe Number = 0, T = 20.155000 C 04:32:51 Temperature Measurement, Probe Number = 1, T = 19.989000 C 04:32:52 Temperature Measurement, Probe Number = 2, T = 19.955000 C 04:32:52 Temperature Measurement, Probe Number = 3, T = 19.946000 C 04:32:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:32:52 Integrated Voltage Measurement... 04:33:12 Voltage Offset Correction: v_off_ini = 0.000001480 V, v_off_fin = 0.000006218 V 04:33:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436885 Vs 04:33:12 Integrated Voltage Measurement... 04:33:31 Voltage Offset Correction: v_off_ini = 0.000005352 V, v_off_fin = -0.000001883 V 04:33:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310470 Vs 05:03:34 Temperature Measurement, Probe Number = 0, T = 20.328000 C 05:03:35 Temperature Measurement, Probe Number = 1, T = 19.982000 C 05:03:35 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:03:36 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:03:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:03:36 Integrated Voltage Measurement... 05:03:55 Voltage Offset Correction: v_off_ini = 0.000003413 V, v_off_fin = 0.000006445 V 05:03:55 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175524611 Vs 05:03:56 Integrated Voltage Measurement... 05:04:15 Voltage Offset Correction: v_off_ini = 0.000005448 V, v_off_fin = -0.000001912 V 05:04:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304507 Vs 05:04:18 Temperature Measurement, Probe Number = 0, T = 20.360000 C 05:04:19 Temperature Measurement, Probe Number = 1, T = 19.985000 C 05:04:19 Temperature Measurement, Probe Number = 2, T = 19.958000 C 05:04:20 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:04:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:04:20 Integrated Voltage Measurement... 05:04:39 Voltage Offset Correction: v_off_ini = 0.000001563 V, v_off_fin = 0.000005782 V 05:04:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422580 Vs 05:04:39 Integrated Voltage Measurement... 05:04:58 Voltage Offset Correction: v_off_ini = 0.000004899 V, v_off_fin = -0.000001863 V 05:04:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300679 Vs 05:05:01 Temperature Measurement, Probe Number = 0, T = 20.341000 C 05:05:02 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:05:03 Temperature Measurement, Probe Number = 2, T = 19.958000 C 05:05:03 Temperature Measurement, Probe Number = 3, T = 19.948000 C 05:05:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:05:03 Integrated Voltage Measurement... 05:05:22 Voltage Offset Correction: v_off_ini = 0.000002214 V, v_off_fin = 0.000005947 V 05:05:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428221 Vs 05:05:23 Integrated Voltage Measurement... 05:05:42 Voltage Offset Correction: v_off_ini = 0.000005491 V, v_off_fin = -0.000001198 V 05:05:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292172 Vs 05:05:45 Temperature Measurement, Probe Number = 0, T = 20.367000 C 05:05:46 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:05:46 Temperature Measurement, Probe Number = 2, T = 19.956000 C 05:05:47 Temperature Measurement, Probe Number = 3, T = 19.947000 C 05:05:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:05:47 Integrated Voltage Measurement... 05:06:06 Voltage Offset Correction: v_off_ini = 0.000001737 V, v_off_fin = 0.000006003 V 05:06:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423764 Vs 05:06:07 Integrated Voltage Measurement... 05:06:26 Voltage Offset Correction: v_off_ini = 0.000005422 V, v_off_fin = -0.000002343 V 05:06:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302168 Vs 05:06:29 Temperature Measurement, Probe Number = 0, T = 20.305000 C 05:06:30 Temperature Measurement, Probe Number = 1, T = 19.984000 C 05:06:30 Temperature Measurement, Probe Number = 2, T = 19.960000 C 05:06:31 Temperature Measurement, Probe Number = 3, T = 19.948000 C 05:06:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:06:31 Integrated Voltage Measurement... 05:06:51 Voltage Offset Correction: v_off_ini = 0.000001267 V, v_off_fin = 0.000005526 V 05:06:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418895 Vs 05:06:51 Integrated Voltage Measurement... 05:07:11 Voltage Offset Correction: v_off_ini = 0.000005017 V, v_off_fin = -0.000002060 V 05:07:11 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298590 Vs 05:07:13 Temperature Measurement, Probe Number = 0, T = 20.293000 C 05:07:14 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:07:15 Temperature Measurement, Probe Number = 2, T = 19.958000 C 05:07:15 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:07:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:07:16 Integrated Voltage Measurement... 05:07:35 Voltage Offset Correction: v_off_ini = 0.000001186 V, v_off_fin = 0.000005881 V 05:07:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417800 Vs 05:07:35 Integrated Voltage Measurement... 05:07:54 Voltage Offset Correction: v_off_ini = 0.000005136 V, v_off_fin = -0.000002515 V 05:07:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301355 Vs 05:07:57 Temperature Measurement, Probe Number = 0, T = 20.281000 C 05:07:58 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:07:59 Temperature Measurement, Probe Number = 2, T = 19.952000 C 05:07:59 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:07:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:07:59 Integrated Voltage Measurement... 05:08:18 Voltage Offset Correction: v_off_ini = 0.000001268 V, v_off_fin = 0.000005864 V 05:08:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420922 Vs 05:08:19 Integrated Voltage Measurement... 05:08:38 Voltage Offset Correction: v_off_ini = 0.000005132 V, v_off_fin = -0.000002619 V 05:08:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306031 Vs 05:08:41 Temperature Measurement, Probe Number = 0, T = 20.198000 C 05:08:42 Temperature Measurement, Probe Number = 1, T = 19.984000 C 05:08:42 Temperature Measurement, Probe Number = 2, T = 19.957000 C 05:08:43 Temperature Measurement, Probe Number = 3, T = 19.945000 C 05:08:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:08:43 Integrated Voltage Measurement... 05:09:03 Voltage Offset Correction: v_off_ini = 0.000001529 V, v_off_fin = 0.000005610 V 05:09:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416296 Vs 05:09:03 Integrated Voltage Measurement... 05:09:22 Voltage Offset Correction: v_off_ini = 0.000004970 V, v_off_fin = -0.000002795 V 05:09:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306575 Vs 05:09:25 Temperature Measurement, Probe Number = 0, T = 20.169000 C 05:09:26 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:09:26 Temperature Measurement, Probe Number = 2, T = 19.956000 C 05:09:27 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:09:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:09:27 Integrated Voltage Measurement... 05:09:46 Voltage Offset Correction: v_off_ini = 0.000001398 V, v_off_fin = 0.000005397 V 05:09:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420913 Vs 05:09:47 Integrated Voltage Measurement... 05:10:06 Voltage Offset Correction: v_off_ini = 0.000004926 V, v_off_fin = -0.000002185 V 05:10:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293271 Vs 05:10:09 Temperature Measurement, Probe Number = 0, T = 20.197000 C 05:10:09 Temperature Measurement, Probe Number = 1, T = 19.982000 C 05:10:10 Temperature Measurement, Probe Number = 2, T = 19.955000 C 05:10:11 Temperature Measurement, Probe Number = 3, T = 19.945000 C 05:10:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:10:11 Integrated Voltage Measurement... 05:10:30 Voltage Offset Correction: v_off_ini = 0.000001437 V, v_off_fin = 0.000005740 V 05:10:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414961 Vs 05:10:30 Integrated Voltage Measurement... 05:10:50 Voltage Offset Correction: v_off_ini = 0.000005139 V, v_off_fin = -0.000001717 V 05:10:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303964 Vs 05:40:53 Temperature Measurement, Probe Number = 0, T = 20.113000 C 05:40:54 Temperature Measurement, Probe Number = 1, T = 19.980000 C 05:40:54 Temperature Measurement, Probe Number = 2, T = 19.952000 C 05:40:55 Temperature Measurement, Probe Number = 3, T = 19.941000 C 05:40:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:40:55 Integrated Voltage Measurement... 05:41:14 Voltage Offset Correction: v_off_ini = 0.000003705 V, v_off_fin = 0.000005488 V 05:41:14 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175504343 Vs 05:41:15 Integrated Voltage Measurement... 05:41:34 Voltage Offset Correction: v_off_ini = 0.000004874 V, v_off_fin = -0.000002171 V 05:41:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290886 Vs 05:41:37 Temperature Measurement, Probe Number = 0, T = 20.173000 C 05:41:37 Temperature Measurement, Probe Number = 1, T = 19.981000 C 05:41:38 Temperature Measurement, Probe Number = 2, T = 19.951000 C 05:41:39 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:41:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:41:39 Integrated Voltage Measurement... 05:41:58 Voltage Offset Correction: v_off_ini = 0.000000846 V, v_off_fin = 0.000005663 V 05:41:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411004 Vs 05:41:58 Integrated Voltage Measurement... 05:42:18 Voltage Offset Correction: v_off_ini = 0.000004809 V, v_off_fin = -0.000001552 V 05:42:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299588 Vs 05:42:20 Temperature Measurement, Probe Number = 0, T = 20.190000 C 05:42:21 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:42:22 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:42:22 Temperature Measurement, Probe Number = 3, T = 19.945000 C 05:42:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:42:23 Integrated Voltage Measurement... 05:42:42 Voltage Offset Correction: v_off_ini = 0.000001893 V, v_off_fin = 0.000005505 V 05:42:42 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175408304 Vs 05:42:42 Integrated Voltage Measurement... 05:43:01 Voltage Offset Correction: v_off_ini = 0.000005293 V, v_off_fin = -0.000002307 V 05:43:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297218 Vs 05:43:04 Temperature Measurement, Probe Number = 0, T = 20.241000 C 05:43:05 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:43:06 Temperature Measurement, Probe Number = 2, T = 19.955000 C 05:43:06 Temperature Measurement, Probe Number = 3, T = 19.947000 C 05:43:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:43:07 Integrated Voltage Measurement... 05:43:26 Voltage Offset Correction: v_off_ini = 0.000001553 V, v_off_fin = 0.000005543 V 05:43:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414211 Vs 05:43:26 Integrated Voltage Measurement... 05:43:46 Voltage Offset Correction: v_off_ini = 0.000004843 V, v_off_fin = -0.000002100 V 05:43:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303333 Vs 05:43:49 Temperature Measurement, Probe Number = 0, T = 20.236000 C 05:43:49 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:43:50 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:43:51 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:43:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:43:51 Integrated Voltage Measurement... 05:44:10 Voltage Offset Correction: v_off_ini = 0.000001227 V, v_off_fin = 0.000005796 V 05:44:10 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175409370 Vs 05:44:10 Integrated Voltage Measurement... 05:44:30 Voltage Offset Correction: v_off_ini = 0.000005267 V, v_off_fin = -0.000002091 V 05:44:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305179 Vs 05:44:33 Temperature Measurement, Probe Number = 0, T = 20.290000 C 05:44:33 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:44:34 Temperature Measurement, Probe Number = 2, T = 19.951000 C 05:44:35 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:44:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:44:35 Integrated Voltage Measurement... 05:44:54 Voltage Offset Correction: v_off_ini = 0.000001327 V, v_off_fin = 0.000005638 V 05:44:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413141 Vs 05:44:54 Integrated Voltage Measurement... 05:45:14 Voltage Offset Correction: v_off_ini = 0.000004277 V, v_off_fin = -0.000001466 V 05:45:14 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175297202 Vs 05:45:17 Temperature Measurement, Probe Number = 0, T = 20.267000 C 05:45:17 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:45:18 Temperature Measurement, Probe Number = 2, T = 19.953000 C 05:45:19 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:45:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:45:19 Integrated Voltage Measurement... 05:45:39 Voltage Offset Correction: v_off_ini = 0.000001778 V, v_off_fin = 0.000005197 V 05:45:39 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175407423 Vs 05:45:39 Integrated Voltage Measurement... 05:45:58 Voltage Offset Correction: v_off_ini = 0.000004650 V, v_off_fin = -0.000002096 V 05:45:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293434 Vs 05:46:01 Temperature Measurement, Probe Number = 0, T = 20.229000 C 05:46:02 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:46:02 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:46:03 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:46:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:46:03 Integrated Voltage Measurement... 05:46:22 Voltage Offset Correction: v_off_ini = 0.000002146 V, v_off_fin = 0.000005887 V 05:46:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422189 Vs 05:46:23 Integrated Voltage Measurement... 05:46:42 Voltage Offset Correction: v_off_ini = 0.000005323 V, v_off_fin = -0.000001184 V 05:46:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290805 Vs 05:46:45 Temperature Measurement, Probe Number = 0, T = 20.179000 C 05:46:46 Temperature Measurement, Probe Number = 1, T = 19.979000 C 05:46:46 Temperature Measurement, Probe Number = 2, T = 19.950000 C 05:46:47 Temperature Measurement, Probe Number = 3, T = 19.940000 C 05:46:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:46:47 Integrated Voltage Measurement... 05:47:06 Voltage Offset Correction: v_off_ini = 0.000001541 V, v_off_fin = 0.000006240 V 05:47:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175418073 Vs 05:47:07 Integrated Voltage Measurement... 05:47:26 Voltage Offset Correction: v_off_ini = 0.000005688 V, v_off_fin = -0.000002074 V 05:47:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303227 Vs 05:47:29 Temperature Measurement, Probe Number = 0, T = 20.176000 C 05:47:30 Temperature Measurement, Probe Number = 1, T = 19.980000 C 05:47:31 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:47:31 Temperature Measurement, Probe Number = 3, T = 19.945000 C 05:47:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:47:31 Integrated Voltage Measurement... 05:47:50 Voltage Offset Correction: v_off_ini = 0.000001740 V, v_off_fin = 0.000006401 V 05:47:51 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175419882 Vs 05:47:51 Integrated Voltage Measurement... 05:48:10 Voltage Offset Correction: v_off_ini = 0.000005451 V, v_off_fin = -0.000001221 V 05:48:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296996 Vs 06:18:13 Temperature Measurement, Probe Number = 0, T = 20.150000 C 06:18:14 Temperature Measurement, Probe Number = 1, T = 19.976000 C 06:18:14 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:18:15 Temperature Measurement, Probe Number = 3, T = 19.940000 C 06:18:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:18:15 Integrated Voltage Measurement... 06:18:34 Voltage Offset Correction: v_off_ini = 0.000003404 V, v_off_fin = 0.000005701 V 06:18:34 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175511348 Vs 06:18:34 Integrated Voltage Measurement... 06:18:54 Voltage Offset Correction: v_off_ini = 0.000005002 V, v_off_fin = -0.000001895 V 06:18:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303480 Vs 06:18:57 Temperature Measurement, Probe Number = 0, T = 20.169000 C 06:18:57 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:18:58 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:18:58 Temperature Measurement, Probe Number = 3, T = 19.944000 C 06:18:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:18:59 Integrated Voltage Measurement... 06:19:18 Voltage Offset Correction: v_off_ini = 0.000001946 V, v_off_fin = 0.000005717 V 06:19:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424453 Vs 06:19:18 Integrated Voltage Measurement... 06:19:37 Voltage Offset Correction: v_off_ini = 0.000005526 V, v_off_fin = -0.000002715 V 06:19:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298031 Vs 06:19:40 Temperature Measurement, Probe Number = 0, T = 20.185000 C 06:19:41 Temperature Measurement, Probe Number = 1, T = 19.978000 C 06:19:41 Temperature Measurement, Probe Number = 2, T = 19.947000 C 06:19:42 Temperature Measurement, Probe Number = 3, T = 19.938000 C 06:19:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:19:42 Integrated Voltage Measurement... 06:20:01 Voltage Offset Correction: v_off_ini = 0.000001676 V, v_off_fin = 0.000005782 V 06:20:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421548 Vs 06:20:02 Integrated Voltage Measurement... 06:20:21 Voltage Offset Correction: v_off_ini = 0.000005117 V, v_off_fin = -0.000002193 V 06:20:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307385 Vs 06:20:24 Temperature Measurement, Probe Number = 0, T = 20.223000 C 06:20:24 Temperature Measurement, Probe Number = 1, T = 19.978000 C 06:20:25 Temperature Measurement, Probe Number = 2, T = 19.944000 C 06:20:26 Temperature Measurement, Probe Number = 3, T = 19.937000 C 06:20:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.94 P3 = Top 1, Value = 19.94 06:20:26 Integrated Voltage Measurement... 06:20:45 Voltage Offset Correction: v_off_ini = 0.000001244 V, v_off_fin = 0.000005382 V 06:20:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422098 Vs 06:20:46 Integrated Voltage Measurement... 06:21:05 Voltage Offset Correction: v_off_ini = 0.000004552 V, v_off_fin = -0.000001966 V 06:21:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308003 Vs 06:21:08 Temperature Measurement, Probe Number = 0, T = 20.208000 C 06:21:09 Temperature Measurement, Probe Number = 1, T = 19.978000 C 06:21:09 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:21:10 Temperature Measurement, Probe Number = 3, T = 19.939000 C 06:21:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:21:10 Integrated Voltage Measurement... 06:21:29 Voltage Offset Correction: v_off_ini = 0.000001490 V, v_off_fin = 0.000005400 V 06:21:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419297 Vs 06:21:30 Integrated Voltage Measurement... 06:21:49 Voltage Offset Correction: v_off_ini = 0.000004791 V, v_off_fin = -0.000001956 V 06:21:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304117 Vs 06:21:52 Temperature Measurement, Probe Number = 0, T = 20.222000 C 06:21:53 Temperature Measurement, Probe Number = 1, T = 19.978000 C 06:21:53 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:21:54 Temperature Measurement, Probe Number = 3, T = 19.941000 C 06:21:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:21:54 Integrated Voltage Measurement... 06:22:13 Voltage Offset Correction: v_off_ini = 0.000000944 V, v_off_fin = 0.000005792 V 06:22:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416212 Vs 06:22:14 Integrated Voltage Measurement... 06:22:33 Voltage Offset Correction: v_off_ini = 0.000005350 V, v_off_fin = -0.000002164 V 06:22:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306505 Vs 06:22:36 Temperature Measurement, Probe Number = 0, T = 20.258000 C 06:22:37 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:22:37 Temperature Measurement, Probe Number = 2, T = 19.948000 C 06:22:38 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:22:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:22:38 Integrated Voltage Measurement... 06:22:57 Voltage Offset Correction: v_off_ini = 0.000001847 V, v_off_fin = 0.000005926 V 06:22:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423867 Vs 06:22:58 Integrated Voltage Measurement... 06:23:17 Voltage Offset Correction: v_off_ini = 0.000004912 V, v_off_fin = -0.000002470 V 06:23:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304454 Vs 06:23:20 Temperature Measurement, Probe Number = 0, T = 20.237000 C 06:23:21 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:23:21 Temperature Measurement, Probe Number = 2, T = 19.949000 C 06:23:22 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:23:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:23:22 Integrated Voltage Measurement... 06:23:41 Voltage Offset Correction: v_off_ini = 0.000001053 V, v_off_fin = 0.000005954 V 06:23:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421404 Vs 06:23:42 Integrated Voltage Measurement... 06:24:01 Voltage Offset Correction: v_off_ini = 0.000005325 V, v_off_fin = -0.000002713 V 06:24:01 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299009 Vs 06:24:03 Temperature Measurement, Probe Number = 0, T = 20.253000 C 06:24:04 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:24:05 Temperature Measurement, Probe Number = 2, T = 19.949000 C 06:24:05 Temperature Measurement, Probe Number = 3, T = 19.943000 C 06:24:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:24:06 Integrated Voltage Measurement... 06:24:25 Voltage Offset Correction: v_off_ini = 0.000000853 V, v_off_fin = 0.000005416 V 06:24:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175424568 Vs 06:24:25 Integrated Voltage Measurement... 06:24:44 Voltage Offset Correction: v_off_ini = 0.000005239 V, v_off_fin = -0.000001875 V 06:24:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296252 Vs 06:24:47 Temperature Measurement, Probe Number = 0, T = 20.258000 C 06:24:48 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:24:48 Temperature Measurement, Probe Number = 2, T = 19.951000 C 06:24:49 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:24:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:24:49 Integrated Voltage Measurement... 06:25:09 Voltage Offset Correction: v_off_ini = 0.000001991 V, v_off_fin = 0.000006147 V 06:25:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427878 Vs 06:25:09 Integrated Voltage Measurement... 06:25:29 Voltage Offset Correction: v_off_ini = 0.000005232 V, v_off_fin = -0.000001936 V 06:25:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306609 Vs 06:55:32 Temperature Measurement, Probe Number = 0, T = 20.272000 C 06:55:32 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:55:33 Temperature Measurement, Probe Number = 2, T = 19.953000 C 06:55:33 Temperature Measurement, Probe Number = 3, T = 19.940000 C 06:55:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:55:34 Integrated Voltage Measurement... 06:55:54 Voltage Offset Correction: v_off_ini = 0.000004254 V, v_off_fin = 0.000005755 V 06:55:54 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175515676 Vs 06:55:54 Integrated Voltage Measurement... 06:56:13 Voltage Offset Correction: v_off_ini = 0.000004951 V, v_off_fin = -0.000002030 V 06:56:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298476 Vs 06:56:16 Temperature Measurement, Probe Number = 0, T = 20.302000 C 06:56:17 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:56:17 Temperature Measurement, Probe Number = 2, T = 19.953000 C 06:56:18 Temperature Measurement, Probe Number = 3, T = 19.943000 C 06:56:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:56:18 Integrated Voltage Measurement... 06:56:37 Voltage Offset Correction: v_off_ini = 0.000001552 V, v_off_fin = 0.000006043 V 06:56:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421963 Vs 06:56:38 Integrated Voltage Measurement... 06:56:57 Voltage Offset Correction: v_off_ini = 0.000005376 V, v_off_fin = -0.000002600 V 06:56:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175299993 Vs 06:56:59 Temperature Measurement, Probe Number = 0, T = 20.265000 C 06:57:00 Temperature Measurement, Probe Number = 1, T = 19.981000 C 06:57:01 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:57:01 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:57:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:57:01 Integrated Voltage Measurement... 06:57:21 Voltage Offset Correction: v_off_ini = 0.000002208 V, v_off_fin = 0.000006366 V 06:57:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430235 Vs 06:57:21 Integrated Voltage Measurement... 06:57:40 Voltage Offset Correction: v_off_ini = 0.000005394 V, v_off_fin = -0.000002662 V 06:57:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304094 Vs 06:57:43 Temperature Measurement, Probe Number = 0, T = 20.225000 C 06:57:44 Temperature Measurement, Probe Number = 1, T = 19.984000 C 06:57:44 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:57:45 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:57:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:57:45 Integrated Voltage Measurement... 06:58:05 Voltage Offset Correction: v_off_ini = 0.000001340 V, v_off_fin = 0.000005679 V 06:58:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427010 Vs 06:58:05 Integrated Voltage Measurement... 06:58:25 Voltage Offset Correction: v_off_ini = 0.000004982 V, v_off_fin = -0.000001700 V 06:58:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299758 Vs 06:58:27 Temperature Measurement, Probe Number = 0, T = 20.267000 C 06:58:28 Temperature Measurement, Probe Number = 1, T = 19.986000 C 06:58:29 Temperature Measurement, Probe Number = 2, T = 19.955000 C 06:58:29 Temperature Measurement, Probe Number = 3, T = 19.945000 C 06:58:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 06:58:29 Integrated Voltage Measurement... 06:58:49 Voltage Offset Correction: v_off_ini = 0.000001229 V, v_off_fin = 0.000005950 V 06:58:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423075 Vs 06:58:49 Integrated Voltage Measurement... 06:59:09 Voltage Offset Correction: v_off_ini = 0.000005308 V, v_off_fin = -0.000001974 V 06:59:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304873 Vs 06:59:11 Temperature Measurement, Probe Number = 0, T = 20.298000 C 06:59:12 Temperature Measurement, Probe Number = 1, T = 19.983000 C 06:59:13 Temperature Measurement, Probe Number = 2, T = 19.953000 C 06:59:13 Temperature Measurement, Probe Number = 3, T = 19.943000 C 06:59:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:59:14 Integrated Voltage Measurement... 06:59:33 Voltage Offset Correction: v_off_ini = 0.000001341 V, v_off_fin = 0.000005925 V 06:59:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421060 Vs 06:59:33 Integrated Voltage Measurement... 06:59:53 Voltage Offset Correction: v_off_ini = 0.000005003 V, v_off_fin = -0.000002115 V 06:59:53 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175299032 Vs 06:59:56 Temperature Measurement, Probe Number = 0, T = 20.288000 C 06:59:56 Temperature Measurement, Probe Number = 1, T = 19.985000 C 06:59:57 Temperature Measurement, Probe Number = 2, T = 19.955000 C 06:59:58 Temperature Measurement, Probe Number = 3, T = 19.947000 C 06:59:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 06:59:58 Integrated Voltage Measurement... 07:00:17 Voltage Offset Correction: v_off_ini = 0.000002296 V, v_off_fin = 0.000006046 V 07:00:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175417665 Vs 07:00:17 Integrated Voltage Measurement... 07:00:37 Voltage Offset Correction: v_off_ini = 0.000005093 V, v_off_fin = -0.000001951 V 07:00:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300390 Vs 07:00:40 Temperature Measurement, Probe Number = 0, T = 20.295000 C 07:00:40 Temperature Measurement, Probe Number = 1, T = 19.984000 C 07:00:41 Temperature Measurement, Probe Number = 2, T = 19.957000 C 07:00:41 Temperature Measurement, Probe Number = 3, T = 19.947000 C 07:00:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:00:42 Integrated Voltage Measurement... 07:01:01 Voltage Offset Correction: v_off_ini = 0.000001381 V, v_off_fin = 0.000006403 V 07:01:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425117 Vs 07:01:01 Integrated Voltage Measurement... 07:01:21 Voltage Offset Correction: v_off_ini = 0.000005499 V, v_off_fin = -0.000001731 V 07:01:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296867 Vs 07:01:24 Temperature Measurement, Probe Number = 0, T = 20.323000 C 07:01:25 Temperature Measurement, Probe Number = 1, T = 19.981000 C 07:01:25 Temperature Measurement, Probe Number = 2, T = 19.955000 C 07:01:26 Temperature Measurement, Probe Number = 3, T = 19.947000 C 07:01:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 07:01:26 Integrated Voltage Measurement... 07:01:45 Voltage Offset Correction: v_off_ini = 0.000001269 V, v_off_fin = 0.000005948 V 07:01:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175421236 Vs 07:01:45 Integrated Voltage Measurement... 07:02:05 Voltage Offset Correction: v_off_ini = 0.000005328 V, v_off_fin = -0.000001645 V 07:02:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299629 Vs 07:02:08 Temperature Measurement, Probe Number = 0, T = 20.319000 C 07:02:08 Temperature Measurement, Probe Number = 1, T = 19.982000 C 07:02:09 Temperature Measurement, Probe Number = 2, T = 19.953000 C 07:02:09 Temperature Measurement, Probe Number = 3, T = 19.945000 C 07:02:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 07:02:10 Integrated Voltage Measurement... 07:02:30 Voltage Offset Correction: v_off_ini = 0.000001086 V, v_off_fin = 0.000005627 V 07:02:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420844 Vs 07:02:30 Integrated Voltage Measurement... 07:02:49 Voltage Offset Correction: v_off_ini = 0.000005329 V, v_off_fin = -0.000002374 V 07:02:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295481 Vs 07:32:52 Temperature Measurement, Probe Number = 0, T = 20.207000 C 07:32:53 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:32:53 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:32:54 Temperature Measurement, Probe Number = 3, T = 19.941000 C 07:32:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:32:54 Integrated Voltage Measurement... 07:33:14 Voltage Offset Correction: v_off_ini = 0.000003793 V, v_off_fin = 0.000005513 V 07:33:14 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175522152 Vs 07:33:14 Integrated Voltage Measurement... 07:33:33 Voltage Offset Correction: v_off_ini = 0.000004750 V, v_off_fin = -0.000003115 V 07:33:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295312 Vs 07:33:36 Temperature Measurement, Probe Number = 0, T = 20.201000 C 07:33:37 Temperature Measurement, Probe Number = 1, T = 19.979000 C 07:33:37 Temperature Measurement, Probe Number = 2, T = 19.952000 C 07:33:38 Temperature Measurement, Probe Number = 3, T = 19.943000 C 07:33:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:33:38 Integrated Voltage Measurement... 07:33:58 Voltage Offset Correction: v_off_ini = 0.000001080 V, v_off_fin = 0.000005827 V 07:33:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421473 Vs 07:33:58 Integrated Voltage Measurement... 07:34:17 Voltage Offset Correction: v_off_ini = 0.000004657 V, v_off_fin = -0.000002317 V 07:34:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293604 Vs 07:34:20 Temperature Measurement, Probe Number = 0, T = 20.217000 C 07:34:21 Temperature Measurement, Probe Number = 1, T = 19.980000 C 07:34:21 Temperature Measurement, Probe Number = 2, T = 19.954000 C 07:34:22 Temperature Measurement, Probe Number = 3, T = 19.943000 C 07:34:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:34:22 Integrated Voltage Measurement... 07:34:41 Voltage Offset Correction: v_off_ini = 0.000000863 V, v_off_fin = 0.000005785 V 07:34:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423081 Vs 07:34:41 Integrated Voltage Measurement... 07:35:01 Voltage Offset Correction: v_off_ini = 0.000005266 V, v_off_fin = -0.000001662 V 07:35:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175295039 Vs 07:35:04 Temperature Measurement, Probe Number = 0, T = 20.268000 C 07:35:04 Temperature Measurement, Probe Number = 1, T = 19.977000 C 07:35:05 Temperature Measurement, Probe Number = 2, T = 19.949000 C 07:35:06 Temperature Measurement, Probe Number = 3, T = 19.941000 C 07:35:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:35:06 Integrated Voltage Measurement... 07:35:25 Voltage Offset Correction: v_off_ini = 0.000001319 V, v_off_fin = 0.000005448 V 07:35:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416249 Vs 07:35:25 Integrated Voltage Measurement... 07:35:44 Voltage Offset Correction: v_off_ini = 0.000004978 V, v_off_fin = -0.000002639 V 07:35:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294780 Vs 07:35:47 Temperature Measurement, Probe Number = 0, T = 20.326000 C 07:35:48 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:35:48 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:35:49 Temperature Measurement, Probe Number = 3, T = 19.940000 C 07:35:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:35:49 Integrated Voltage Measurement... 07:36:09 Voltage Offset Correction: v_off_ini = 0.000002055 V, v_off_fin = 0.000005630 V 07:36:09 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431060 Vs 07:36:10 Integrated Voltage Measurement... 07:36:29 Voltage Offset Correction: v_off_ini = 0.000004668 V, v_off_fin = -0.000001793 V 07:36:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297888 Vs 07:36:32 Temperature Measurement, Probe Number = 0, T = 20.241000 C 07:36:32 Temperature Measurement, Probe Number = 1, T = 19.980000 C 07:36:33 Temperature Measurement, Probe Number = 2, T = 19.953000 C 07:36:34 Temperature Measurement, Probe Number = 3, T = 19.943000 C 07:36:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:36:34 Integrated Voltage Measurement... 07:36:53 Voltage Offset Correction: v_off_ini = 0.000001270 V, v_off_fin = 0.000006357 V 07:36:53 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431266 Vs 07:36:54 Integrated Voltage Measurement... 07:37:13 Voltage Offset Correction: v_off_ini = 0.000005432 V, v_off_fin = -0.000002497 V 07:37:13 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300812 Vs 07:37:16 Temperature Measurement, Probe Number = 0, T = 20.255000 C 07:37:17 Temperature Measurement, Probe Number = 1, T = 19.979000 C 07:37:17 Temperature Measurement, Probe Number = 2, T = 19.952000 C 07:37:18 Temperature Measurement, Probe Number = 3, T = 19.943000 C 07:37:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:37:18 Integrated Voltage Measurement... 07:37:37 Voltage Offset Correction: v_off_ini = 0.000001251 V, v_off_fin = 0.000005954 V 07:37:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424465 Vs 07:37:38 Integrated Voltage Measurement... 07:37:57 Voltage Offset Correction: v_off_ini = 0.000005444 V, v_off_fin = -0.000002153 V 07:37:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302905 Vs 07:38:00 Temperature Measurement, Probe Number = 0, T = 20.243000 C 07:38:01 Temperature Measurement, Probe Number = 1, T = 19.983000 C 07:38:01 Temperature Measurement, Probe Number = 2, T = 19.952000 C 07:38:02 Temperature Measurement, Probe Number = 3, T = 19.946000 C 07:38:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 07:38:02 Integrated Voltage Measurement... 07:38:22 Voltage Offset Correction: v_off_ini = 0.000001689 V, v_off_fin = 0.000005894 V 07:38:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426855 Vs 07:38:22 Integrated Voltage Measurement... 07:38:42 Voltage Offset Correction: v_off_ini = 0.000004994 V, v_off_fin = -0.000002107 V 07:38:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291825 Vs 07:38:44 Temperature Measurement, Probe Number = 0, T = 20.225000 C 07:38:45 Temperature Measurement, Probe Number = 1, T = 19.983000 C 07:38:46 Temperature Measurement, Probe Number = 2, T = 19.948000 C 07:38:46 Temperature Measurement, Probe Number = 3, T = 19.944000 C 07:38:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:38:47 Integrated Voltage Measurement... 07:39:05 Voltage Offset Correction: v_off_ini = 0.000002203 V, v_off_fin = 0.000006324 V 07:39:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175424991 Vs 07:39:06 Integrated Voltage Measurement... 07:39:26 Voltage Offset Correction: v_off_ini = 0.000005343 V, v_off_fin = -0.000001926 V 07:39:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303064 Vs 07:39:28 Temperature Measurement, Probe Number = 0, T = 20.239000 C 07:39:29 Temperature Measurement, Probe Number = 1, T = 19.981000 C 07:39:30 Temperature Measurement, Probe Number = 2, T = 19.950000 C 07:39:30 Temperature Measurement, Probe Number = 3, T = 19.941000 C 07:39:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:39:31 Integrated Voltage Measurement... 07:39:50 Voltage Offset Correction: v_off_ini = 0.000001856 V, v_off_fin = 0.000005476 V 07:39:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414793 Vs 07:39:50 Integrated Voltage Measurement... 07:40:09 Voltage Offset Correction: v_off_ini = 0.000004954 V, v_off_fin = -0.000001924 V 07:40:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296462 Vs 08:10:12 Temperature Measurement, Probe Number = 0, T = 20.321000 C 08:10:13 Temperature Measurement, Probe Number = 1, T = 19.977000 C 08:10:14 Temperature Measurement, Probe Number = 2, T = 19.950000 C 08:10:14 Temperature Measurement, Probe Number = 3, T = 19.938000 C 08:10:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 08:10:14 Integrated Voltage Measurement... 08:10:34 Voltage Offset Correction: v_off_ini = 0.000004354 V, v_off_fin = 0.000005894 V 08:10:34 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175523890 Vs 08:10:35 Integrated Voltage Measurement... 08:10:54 Voltage Offset Correction: v_off_ini = 0.000005420 V, v_off_fin = -0.000001738 V 08:10:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292553 Vs 08:10:57 Temperature Measurement, Probe Number = 0, T = 20.312000 C 08:10:58 Temperature Measurement, Probe Number = 1, T = 19.980000 C 08:10:58 Temperature Measurement, Probe Number = 2, T = 19.954000 C 08:10:59 Temperature Measurement, Probe Number = 3, T = 19.942000 C 08:10:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 08:10:59 Integrated Voltage Measurement... 08:11:18 Voltage Offset Correction: v_off_ini = 0.000001074 V, v_off_fin = 0.000006403 V 08:11:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422721 Vs 08:11:19 Integrated Voltage Measurement... 08:11:38 Voltage Offset Correction: v_off_ini = 0.000005618 V, v_off_fin = -0.000001646 V 08:11:38 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296132 Vs 08:11:41 Temperature Measurement, Probe Number = 0, T = 20.319000 C 08:11:42 Temperature Measurement, Probe Number = 1, T = 19.982000 C 08:11:42 Temperature Measurement, Probe Number = 2, T = 19.954000 C 08:11:43 Temperature Measurement, Probe Number = 3, T = 19.944000 C 08:11:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 08:11:43 Integrated Voltage Measurement... 08:12:03 Voltage Offset Correction: v_off_ini = 0.000002009 V, v_off_fin = 0.000006360 V 08:12:03 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427411 Vs 08:12:04 Integrated Voltage Measurement... 08:12:23 Voltage Offset Correction: v_off_ini = 0.000005444 V, v_off_fin = -0.000002811 V 08:12:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286932 Vs 08:12:25 Temperature Measurement, Probe Number = 0, T = 20.367000 C 08:12:26 Temperature Measurement, Probe Number = 1, T = 19.982000 C 08:12:27 Temperature Measurement, Probe Number = 2, T = 19.955000 C 08:12:27 Temperature Measurement, Probe Number = 3, T = 19.943000 C 08:12:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 08:12:28 Integrated Voltage Measurement... 08:12:47 Voltage Offset Correction: v_off_ini = 0.000001563 V, v_off_fin = 0.000005880 V 08:12:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426041 Vs 08:12:47 Integrated Voltage Measurement... 08:13:06 Voltage Offset Correction: v_off_ini = 0.000005481 V, v_off_fin = -0.000001581 V 08:13:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300211 Vs 08:13:09 Temperature Measurement, Probe Number = 0, T = 20.355000 C 08:13:10 Temperature Measurement, Probe Number = 1, T = 19.983000 C 08:13:10 Temperature Measurement, Probe Number = 2, T = 19.956000 C 08:13:11 Temperature Measurement, Probe Number = 3, T = 19.943000 C 08:13:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 08:13:11 Integrated Voltage Measurement... 08:13:30 Voltage Offset Correction: v_off_ini = 0.000001853 V, v_off_fin = 0.000006138 V 08:13:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425034 Vs 08:13:31 Integrated Voltage Measurement... 08:13:50 Voltage Offset Correction: v_off_ini = 0.000005673 V, v_off_fin = -0.000002684 V 08:13:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293217 Vs 08:13:53 Temperature Measurement, Probe Number = 0, T = 20.328000 C 08:13:53 Temperature Measurement, Probe Number = 1, T = 19.982000 C 08:13:54 Temperature Measurement, Probe Number = 2, T = 19.957000 C 08:13:55 Temperature Measurement, Probe Number = 3, T = 19.943000 C 08:13:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 08:13:55 Integrated Voltage Measurement... 08:14:14 Voltage Offset Correction: v_off_ini = 0.000001145 V, v_off_fin = 0.000006073 V 08:14:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423882 Vs 08:14:14 Integrated Voltage Measurement... 08:14:33 Voltage Offset Correction: v_off_ini = 0.000005400 V, v_off_fin = -0.000002361 V 08:14:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289982 Vs 08:14:36 Temperature Measurement, Probe Number = 0, T = 20.334000 C 08:14:37 Temperature Measurement, Probe Number = 1, T = 19.981000 C 08:14:38 Temperature Measurement, Probe Number = 2, T = 19.958000 C 08:14:38 Temperature Measurement, Probe Number = 3, T = 19.942000 C 08:14:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 08:14:39 Integrated Voltage Measurement... 08:14:58 Voltage Offset Correction: v_off_ini = 0.000002373 V, v_off_fin = 0.000006575 V 08:14:58 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425504 Vs 08:14:58 Integrated Voltage Measurement... 08:15:17 Voltage Offset Correction: v_off_ini = 0.000005534 V, v_off_fin = -0.000001512 V 08:15:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291603 Vs 08:15:20 Temperature Measurement, Probe Number = 0, T = 20.301000 C 08:15:21 Temperature Measurement, Probe Number = 1, T = 19.982000 C 08:15:21 Temperature Measurement, Probe Number = 2, T = 19.957000 C 08:15:22 Temperature Measurement, Probe Number = 3, T = 19.942000 C 08:15:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 08:15:22 Integrated Voltage Measurement... 08:15:42 Voltage Offset Correction: v_off_ini = 0.000001891 V, v_off_fin = 0.000005981 V 08:15:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430308 Vs 08:15:42 Integrated Voltage Measurement... 08:16:02 Voltage Offset Correction: v_off_ini = 0.000005327 V, v_off_fin = -0.000002211 V 08:16:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300328 Vs 08:16:04 Temperature Measurement, Probe Number = 0, T = 20.298000 C 08:16:05 Temperature Measurement, Probe Number = 1, T = 19.985000 C 08:16:06 Temperature Measurement, Probe Number = 2, T = 19.960000 C 08:16:06 Temperature Measurement, Probe Number = 3, T = 19.942000 C 08:16:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 08:16:07 Integrated Voltage Measurement... 08:16:26 Voltage Offset Correction: v_off_ini = 0.000001830 V, v_off_fin = 0.000007338 V 08:16:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430227 Vs 08:16:26 Integrated Voltage Measurement... 08:16:45 Voltage Offset Correction: v_off_ini = 0.000005992 V, v_off_fin = -0.000001577 V 08:16:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296773 Vs 08:16:48 Temperature Measurement, Probe Number = 0, T = 20.335000 C 08:16:49 Temperature Measurement, Probe Number = 1, T = 19.984000 C 08:16:49 Temperature Measurement, Probe Number = 2, T = 19.956000 C 08:16:50 Temperature Measurement, Probe Number = 3, T = 19.946000 C 08:16:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:16:50 Integrated Voltage Measurement... 08:17:09 Voltage Offset Correction: v_off_ini = 0.000001711 V, v_off_fin = 0.000005957 V 08:17:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427732 Vs 08:17:10 Integrated Voltage Measurement... 08:17:29 Voltage Offset Correction: v_off_ini = 0.000005102 V, v_off_fin = -0.000001661 V 08:17:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291911 Vs 08:47:31 Temperature Measurement, Probe Number = 0, T = 20.279000 C 08:47:32 Temperature Measurement, Probe Number = 1, T = 19.987000 C 08:47:33 Temperature Measurement, Probe Number = 2, T = 19.959000 C 08:47:33 Temperature Measurement, Probe Number = 3, T = 19.947000 C 08:47:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:47:34 Integrated Voltage Measurement... 08:47:53 Voltage Offset Correction: v_off_ini = 0.000003583 V, v_off_fin = 0.000005746 V 08:47:53 Integrated Voltage Measurement Delta Gap = 0.0040037 m VT = 0.175527986 Vs 08:47:53 Integrated Voltage Measurement... 08:48:13 Voltage Offset Correction: v_off_ini = 0.000005300 V, v_off_fin = -0.000001764 V 08:48:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300124 Vs 08:48:15 Temperature Measurement, Probe Number = 0, T = 20.313000 C 08:48:16 Temperature Measurement, Probe Number = 1, T = 19.989000 C 08:48:17 Temperature Measurement, Probe Number = 2, T = 19.962000 C 08:48:17 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:48:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:48:18 Integrated Voltage Measurement... 08:48:37 Voltage Offset Correction: v_off_ini = 0.000001361 V, v_off_fin = 0.000005261 V 08:48:37 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420153 Vs 08:48:37 Integrated Voltage Measurement... 08:48:57 Voltage Offset Correction: v_off_ini = 0.000004907 V, v_off_fin = -0.000002265 V 08:48:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302073 Vs 08:48:59 Temperature Measurement, Probe Number = 0, T = 20.339000 C 08:49:00 Temperature Measurement, Probe Number = 1, T = 19.989000 C 08:49:01 Temperature Measurement, Probe Number = 2, T = 19.960000 C 08:49:01 Temperature Measurement, Probe Number = 3, T = 19.950000 C 08:49:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:49:02 Integrated Voltage Measurement... 08:49:21 Voltage Offset Correction: v_off_ini = 0.000000401 V, v_off_fin = 0.000005369 V 08:49:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413021 Vs 08:49:21 Integrated Voltage Measurement... 08:49:41 Voltage Offset Correction: v_off_ini = 0.000005127 V, v_off_fin = -0.000002555 V 08:49:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292146 Vs 08:49:44 Temperature Measurement, Probe Number = 0, T = 20.329000 C 08:49:44 Temperature Measurement, Probe Number = 1, T = 19.992000 C 08:49:45 Temperature Measurement, Probe Number = 2, T = 19.964000 C 08:49:46 Temperature Measurement, Probe Number = 3, T = 19.952000 C 08:49:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:49:46 Integrated Voltage Measurement... 08:50:05 Voltage Offset Correction: v_off_ini = 0.000001096 V, v_off_fin = 0.000005479 V 08:50:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410353 Vs 08:50:05 Integrated Voltage Measurement... 08:50:25 Voltage Offset Correction: v_off_ini = 0.000004732 V, v_off_fin = -0.000001590 V 08:50:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300593 Vs 08:50:28 Temperature Measurement, Probe Number = 0, T = 20.307000 C 08:50:29 Temperature Measurement, Probe Number = 1, T = 19.993000 C 08:50:29 Temperature Measurement, Probe Number = 2, T = 19.966000 C 08:50:30 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:50:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:50:30 Integrated Voltage Measurement... 08:50:49 Voltage Offset Correction: v_off_ini = 0.000001016 V, v_off_fin = 0.000005351 V 08:50:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407848 Vs 08:50:50 Integrated Voltage Measurement... 08:51:09 Voltage Offset Correction: v_off_ini = 0.000004573 V, v_off_fin = -0.000002333 V 08:51:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304066 Vs 08:51:12 Temperature Measurement, Probe Number = 0, T = 20.282000 C 08:51:12 Temperature Measurement, Probe Number = 1, T = 19.994000 C 08:51:13 Temperature Measurement, Probe Number = 2, T = 19.966000 C 08:51:14 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:51:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:51:14 Integrated Voltage Measurement... 08:51:33 Voltage Offset Correction: v_off_ini = 0.000000059 V, v_off_fin = 0.000005308 V 08:51:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404268 Vs 08:51:34 Integrated Voltage Measurement... 08:51:53 Voltage Offset Correction: v_off_ini = 0.000004732 V, v_off_fin = -0.000002593 V 08:51:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313127 Vs 08:51:56 Temperature Measurement, Probe Number = 0, T = 20.300000 C 08:51:56 Temperature Measurement, Probe Number = 1, T = 19.993000 C 08:51:57 Temperature Measurement, Probe Number = 2, T = 19.967000 C 08:51:58 Temperature Measurement, Probe Number = 3, T = 19.950000 C 08:51:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:51:58 Integrated Voltage Measurement... 08:52:17 Voltage Offset Correction: v_off_ini = 0.000000877 V, v_off_fin = 0.000004718 V 08:52:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410365 Vs 08:52:17 Integrated Voltage Measurement... 08:52:36 Voltage Offset Correction: v_off_ini = 0.000004420 V, v_off_fin = -0.000003189 V 08:52:36 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175308452 Vs 08:52:39 Temperature Measurement, Probe Number = 0, T = 20.346000 C 08:52:40 Temperature Measurement, Probe Number = 1, T = 19.992000 C 08:52:41 Temperature Measurement, Probe Number = 2, T = 19.967000 C 08:52:41 Temperature Measurement, Probe Number = 3, T = 19.955000 C 08:52:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:52:41 Integrated Voltage Measurement... 08:53:00 Voltage Offset Correction: v_off_ini = 0.000000209 V, v_off_fin = 0.000004934 V 08:53:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175414116 Vs 08:53:01 Integrated Voltage Measurement... 08:53:20 Voltage Offset Correction: v_off_ini = 0.000004241 V, v_off_fin = -0.000002805 V 08:53:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306471 Vs 08:53:23 Temperature Measurement, Probe Number = 0, T = 20.323000 C 08:53:24 Temperature Measurement, Probe Number = 1, T = 19.992000 C 08:53:24 Temperature Measurement, Probe Number = 2, T = 19.966000 C 08:53:25 Temperature Measurement, Probe Number = 3, T = 19.953000 C 08:53:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:53:25 Integrated Voltage Measurement... 08:53:44 Voltage Offset Correction: v_off_ini = 0.000001454 V, v_off_fin = 0.000005316 V 08:53:45 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175415019 Vs 08:53:45 Integrated Voltage Measurement... 08:54:04 Voltage Offset Correction: v_off_ini = 0.000004980 V, v_off_fin = -0.000002441 V 08:54:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306481 Vs 08:54:07 Temperature Measurement, Probe Number = 0, T = 20.293000 C 08:54:08 Temperature Measurement, Probe Number = 1, T = 19.993000 C 08:54:08 Temperature Measurement, Probe Number = 2, T = 19.966000 C 08:54:09 Temperature Measurement, Probe Number = 3, T = 19.953000 C 08:54:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:54:09 Integrated Voltage Measurement... 08:54:28 Voltage Offset Correction: v_off_ini = 0.000001184 V, v_off_fin = 0.000005590 V 08:54:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416767 Vs 08:54:29 Integrated Voltage Measurement... 08:54:48 Voltage Offset Correction: v_off_ini = 0.000004922 V, v_off_fin = -0.000001906 V 08:54:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305594 Vs 09:24:51 Temperature Measurement, Probe Number = 0, T = 20.221000 C 09:24:52 Temperature Measurement, Probe Number = 1, T = 19.985000 C 09:24:53 Temperature Measurement, Probe Number = 2, T = 19.956000 C 09:24:53 Temperature Measurement, Probe Number = 3, T = 19.943000 C 09:24:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 09:24:54 Integrated Voltage Measurement... 09:25:13 Voltage Offset Correction: v_off_ini = 0.000003356 V, v_off_fin = 0.000005007 V 09:25:13 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175507109 Vs 09:25:13 Integrated Voltage Measurement... 09:25:32 Voltage Offset Correction: v_off_ini = 0.000004701 V, v_off_fin = -0.000001809 V 09:25:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302580 Vs 09:25:35 Temperature Measurement, Probe Number = 0, T = 20.228000 C 09:25:36 Temperature Measurement, Probe Number = 1, T = 19.985000 C 09:25:37 Temperature Measurement, Probe Number = 2, T = 19.956000 C 09:25:37 Temperature Measurement, Probe Number = 3, T = 19.944000 C 09:25:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 09:25:38 Integrated Voltage Measurement... 09:25:57 Voltage Offset Correction: v_off_ini = 0.000000557 V, v_off_fin = 0.000004649 V 09:25:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419400 Vs 09:25:57 Integrated Voltage Measurement... 09:26:16 Voltage Offset Correction: v_off_ini = 0.000004346 V, v_off_fin = -0.000002488 V 09:26:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309199 Vs 09:26:19 Temperature Measurement, Probe Number = 0, T = 20.245000 C 09:26:20 Temperature Measurement, Probe Number = 1, T = 19.987000 C 09:26:21 Temperature Measurement, Probe Number = 2, T = 19.961000 C 09:26:21 Temperature Measurement, Probe Number = 3, T = 19.948000 C 09:26:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:26:22 Integrated Voltage Measurement... 09:26:41 Voltage Offset Correction: v_off_ini = 0.000001072 V, v_off_fin = 0.000005406 V 09:26:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416044 Vs 09:26:41 Integrated Voltage Measurement... 09:27:01 Voltage Offset Correction: v_off_ini = 0.000004579 V, v_off_fin = -0.000001419 V 09:27:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306897 Vs 09:27:03 Temperature Measurement, Probe Number = 0, T = 20.305000 C 09:27:04 Temperature Measurement, Probe Number = 1, T = 19.989000 C 09:27:05 Temperature Measurement, Probe Number = 2, T = 19.961000 C 09:27:05 Temperature Measurement, Probe Number = 3, T = 19.948000 C 09:27:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:27:06 Integrated Voltage Measurement... 09:27:25 Voltage Offset Correction: v_off_ini = 0.000001294 V, v_off_fin = 0.000006279 V 09:27:25 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175420557 Vs 09:27:25 Integrated Voltage Measurement... 09:27:44 Voltage Offset Correction: v_off_ini = 0.000005733 V, v_off_fin = -0.000001906 V 09:27:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293402 Vs 09:27:47 Temperature Measurement, Probe Number = 0, T = 20.323000 C 09:27:48 Temperature Measurement, Probe Number = 1, T = 19.989000 C 09:27:48 Temperature Measurement, Probe Number = 2, T = 19.963000 C 09:27:49 Temperature Measurement, Probe Number = 3, T = 19.949000 C 09:27:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:27:49 Integrated Voltage Measurement... 09:28:09 Voltage Offset Correction: v_off_ini = 0.000001930 V, v_off_fin = 0.000006453 V 09:28:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434812 Vs 09:28:09 Integrated Voltage Measurement... 09:28:28 Voltage Offset Correction: v_off_ini = 0.000005442 V, v_off_fin = -0.000001990 V 09:28:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305608 Vs 09:28:31 Temperature Measurement, Probe Number = 0, T = 20.341000 C 09:28:32 Temperature Measurement, Probe Number = 1, T = 19.988000 C 09:28:32 Temperature Measurement, Probe Number = 2, T = 19.960000 C 09:28:33 Temperature Measurement, Probe Number = 3, T = 19.947000 C 09:28:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:28:33 Integrated Voltage Measurement... 09:28:52 Voltage Offset Correction: v_off_ini = 0.000001612 V, v_off_fin = 0.000006124 V 09:28:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423226 Vs 09:28:53 Integrated Voltage Measurement... 09:29:12 Voltage Offset Correction: v_off_ini = 0.000005350 V, v_off_fin = -0.000002814 V 09:29:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303387 Vs 09:29:15 Temperature Measurement, Probe Number = 0, T = 20.296000 C 09:29:15 Temperature Measurement, Probe Number = 1, T = 19.988000 C 09:29:16 Temperature Measurement, Probe Number = 2, T = 19.959000 C 09:29:16 Temperature Measurement, Probe Number = 3, T = 19.949000 C 09:29:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:29:17 Integrated Voltage Measurement... 09:29:36 Voltage Offset Correction: v_off_ini = 0.000000907 V, v_off_fin = 0.000005583 V 09:29:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175427792 Vs 09:29:36 Integrated Voltage Measurement... 09:29:55 Voltage Offset Correction: v_off_ini = 0.000005522 V, v_off_fin = -0.000001487 V 09:29:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307675 Vs 09:29:58 Temperature Measurement, Probe Number = 0, T = 20.262000 C 09:29:59 Temperature Measurement, Probe Number = 1, T = 19.989000 C 09:30:00 Temperature Measurement, Probe Number = 2, T = 19.963000 C 09:30:00 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:30:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:30:01 Integrated Voltage Measurement... 09:30:20 Voltage Offset Correction: v_off_ini = 0.000001524 V, v_off_fin = 0.000006160 V 09:30:20 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430750 Vs 09:30:20 Integrated Voltage Measurement... 09:30:40 Voltage Offset Correction: v_off_ini = 0.000005417 V, v_off_fin = -0.000002177 V 09:30:40 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306220 Vs 09:30:43 Temperature Measurement, Probe Number = 0, T = 20.243000 C 09:30:43 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:30:44 Temperature Measurement, Probe Number = 2, T = 19.967000 C 09:30:45 Temperature Measurement, Probe Number = 3, T = 19.954000 C 09:30:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:30:45 Integrated Voltage Measurement... 09:31:04 Voltage Offset Correction: v_off_ini = 0.000001331 V, v_off_fin = 0.000005987 V 09:31:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423035 Vs 09:31:04 Integrated Voltage Measurement... 09:31:24 Voltage Offset Correction: v_off_ini = 0.000005147 V, v_off_fin = -0.000002356 V 09:31:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305604 Vs 09:31:27 Temperature Measurement, Probe Number = 0, T = 20.312000 C 09:31:27 Temperature Measurement, Probe Number = 1, T = 19.992000 C 09:31:28 Temperature Measurement, Probe Number = 2, T = 19.964000 C 09:31:29 Temperature Measurement, Probe Number = 3, T = 19.950000 C 09:31:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 09:31:29 Integrated Voltage Measurement... 09:31:48 Voltage Offset Correction: v_off_ini = 0.000002159 V, v_off_fin = 0.000005519 V 09:31:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431183 Vs 09:31:48 Integrated Voltage Measurement... 09:32:08 Voltage Offset Correction: v_off_ini = 0.000004770 V, v_off_fin = -0.000002107 V 09:32:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312056 Vs 10:02:11 Temperature Measurement, Probe Number = 0, T = 20.313000 C 10:02:11 Temperature Measurement, Probe Number = 1, T = 19.994000 C 10:02:12 Temperature Measurement, Probe Number = 2, T = 19.970000 C 10:02:13 Temperature Measurement, Probe Number = 3, T = 19.955000 C 10:02:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:02:13 Integrated Voltage Measurement... 10:02:32 Voltage Offset Correction: v_off_ini = 0.000003684 V, v_off_fin = 0.000005256 V 10:02:32 Integrated Voltage Measurement Delta Gap = 0.0040037 m VT = 0.175528332 Vs 10:02:32 Integrated Voltage Measurement... 10:02:51 Voltage Offset Correction: v_off_ini = 0.000004510 V, v_off_fin = -0.000002861 V 10:02:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301587 Vs 10:02:54 Temperature Measurement, Probe Number = 0, T = 20.273000 C 10:02:55 Temperature Measurement, Probe Number = 1, T = 19.997000 C 10:02:55 Temperature Measurement, Probe Number = 2, T = 19.974000 C 10:02:56 Temperature Measurement, Probe Number = 3, T = 19.958000 C 10:02:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:02:56 Integrated Voltage Measurement... 10:03:16 Voltage Offset Correction: v_off_ini = 0.000001409 V, v_off_fin = 0.000005119 V 10:03:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409098 Vs 10:03:16 Integrated Voltage Measurement... 10:03:36 Voltage Offset Correction: v_off_ini = 0.000004444 V, v_off_fin = -0.000002859 V 10:03:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308938 Vs 10:03:39 Temperature Measurement, Probe Number = 0, T = 20.306000 C 10:03:39 Temperature Measurement, Probe Number = 1, T = 20.000000 C 10:03:40 Temperature Measurement, Probe Number = 2, T = 19.976000 C 10:03:41 Temperature Measurement, Probe Number = 3, T = 19.961000 C 10:03:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:03:41 Integrated Voltage Measurement... 10:04:00 Voltage Offset Correction: v_off_ini = 0.000001280 V, v_off_fin = 0.000005237 V 10:04:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407170 Vs 10:04:00 Integrated Voltage Measurement... 10:04:19 Voltage Offset Correction: v_off_ini = 0.000004382 V, v_off_fin = -0.000002752 V 10:04:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305557 Vs 10:04:22 Temperature Measurement, Probe Number = 0, T = 20.299000 C 10:04:23 Temperature Measurement, Probe Number = 1, T = 19.998000 C 10:04:24 Temperature Measurement, Probe Number = 2, T = 19.973000 C 10:04:24 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:04:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:04:25 Integrated Voltage Measurement... 10:04:44 Voltage Offset Correction: v_off_ini = 0.000001601 V, v_off_fin = 0.000006302 V 10:04:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423569 Vs 10:04:44 Integrated Voltage Measurement... 10:05:04 Voltage Offset Correction: v_off_ini = 0.000005042 V, v_off_fin = -0.000001370 V 10:05:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296520 Vs 10:05:07 Temperature Measurement, Probe Number = 0, T = 20.296000 C 10:05:08 Temperature Measurement, Probe Number = 1, T = 19.995000 C 10:05:08 Temperature Measurement, Probe Number = 2, T = 19.970000 C 10:05:09 Temperature Measurement, Probe Number = 3, T = 19.956000 C 10:05:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:05:09 Integrated Voltage Measurement... 10:05:28 Voltage Offset Correction: v_off_ini = 0.000001129 V, v_off_fin = 0.000005979 V 10:05:28 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175407556 Vs 10:05:28 Integrated Voltage Measurement... 10:05:48 Voltage Offset Correction: v_off_ini = 0.000005066 V, v_off_fin = -0.000002849 V 10:05:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305652 Vs 10:05:51 Temperature Measurement, Probe Number = 0, T = 20.320000 C 10:05:51 Temperature Measurement, Probe Number = 1, T = 20.000000 C 10:05:52 Temperature Measurement, Probe Number = 2, T = 19.973000 C 10:05:53 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:05:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:05:53 Integrated Voltage Measurement... 10:06:12 Voltage Offset Correction: v_off_ini = 0.000000958 V, v_off_fin = 0.000004444 V 10:06:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175414369 Vs 10:06:12 Integrated Voltage Measurement... 10:06:32 Voltage Offset Correction: v_off_ini = 0.000004465 V, v_off_fin = -0.000002684 V 10:06:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313982 Vs 10:06:35 Temperature Measurement, Probe Number = 0, T = 20.330000 C 10:06:35 Temperature Measurement, Probe Number = 1, T = 20.000000 C 10:06:36 Temperature Measurement, Probe Number = 2, T = 19.974000 C 10:06:37 Temperature Measurement, Probe Number = 3, T = 19.961000 C 10:06:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:06:37 Integrated Voltage Measurement... 10:06:56 Voltage Offset Correction: v_off_ini = 0.000001103 V, v_off_fin = 0.000005550 V 10:06:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420502 Vs 10:06:56 Integrated Voltage Measurement... 10:07:16 Voltage Offset Correction: v_off_ini = 0.000004571 V, v_off_fin = -0.000002853 V 10:07:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310166 Vs 10:07:19 Temperature Measurement, Probe Number = 0, T = 20.341000 C 10:07:20 Temperature Measurement, Probe Number = 1, T = 19.998000 C 10:07:20 Temperature Measurement, Probe Number = 2, T = 19.972000 C 10:07:21 Temperature Measurement, Probe Number = 3, T = 19.960000 C 10:07:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:07:21 Integrated Voltage Measurement... 10:07:40 Voltage Offset Correction: v_off_ini = 0.000001138 V, v_off_fin = 0.000005826 V 10:07:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414240 Vs 10:07:41 Integrated Voltage Measurement... 10:08:00 Voltage Offset Correction: v_off_ini = 0.000004507 V, v_off_fin = -0.000002261 V 10:08:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302058 Vs 10:08:03 Temperature Measurement, Probe Number = 0, T = 20.284000 C 10:08:03 Temperature Measurement, Probe Number = 1, T = 19.999000 C 10:08:04 Temperature Measurement, Probe Number = 2, T = 19.974000 C 10:08:05 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:08:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:08:05 Integrated Voltage Measurement... 10:08:24 Voltage Offset Correction: v_off_ini = 0.000001572 V, v_off_fin = 0.000005801 V 10:08:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422582 Vs 10:08:25 Integrated Voltage Measurement... 10:08:44 Voltage Offset Correction: v_off_ini = 0.000004954 V, v_off_fin = -0.000002452 V 10:08:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303461 Vs 10:08:47 Temperature Measurement, Probe Number = 0, T = 20.301000 C 10:08:47 Temperature Measurement, Probe Number = 1, T = 20.001000 C 10:08:48 Temperature Measurement, Probe Number = 2, T = 19.975000 C 10:08:49 Temperature Measurement, Probe Number = 3, T = 19.963000 C 10:08:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:08:49 Integrated Voltage Measurement... 10:09:08 Voltage Offset Correction: v_off_ini = 0.000000989 V, v_off_fin = 0.000005447 V 10:09:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418819 Vs 10:09:09 Integrated Voltage Measurement... 10:09:28 Voltage Offset Correction: v_off_ini = 0.000004795 V, v_off_fin = -0.000002888 V 10:09:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313079 Vs 10:39:31 Temperature Measurement, Probe Number = 0, T = 20.311000 C 10:39:32 Temperature Measurement, Probe Number = 1, T = 19.999000 C 10:39:33 Temperature Measurement, Probe Number = 2, T = 19.973000 C 10:39:33 Temperature Measurement, Probe Number = 3, T = 19.957000 C 10:39:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 10:39:34 Integrated Voltage Measurement... 10:39:53 Voltage Offset Correction: v_off_ini = 0.000003821 V, v_off_fin = 0.000005675 V 10:39:53 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175517113 Vs 10:39:53 Integrated Voltage Measurement... 10:40:12 Voltage Offset Correction: v_off_ini = 0.000004827 V, v_off_fin = -0.000002992 V 10:40:12 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175306848 Vs 10:40:15 Temperature Measurement, Probe Number = 0, T = 20.256000 C 10:40:16 Temperature Measurement, Probe Number = 1, T = 20.002000 C 10:40:16 Temperature Measurement, Probe Number = 2, T = 19.978000 C 10:40:17 Temperature Measurement, Probe Number = 3, T = 19.960000 C 10:40:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:40:17 Integrated Voltage Measurement... 10:40:36 Voltage Offset Correction: v_off_ini = 0.000001144 V, v_off_fin = 0.000005344 V 10:40:36 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175419714 Vs 10:40:37 Integrated Voltage Measurement... 10:40:56 Voltage Offset Correction: v_off_ini = 0.000004819 V, v_off_fin = -0.000002494 V 10:40:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305564 Vs 10:40:59 Temperature Measurement, Probe Number = 0, T = 20.296000 C 10:41:00 Temperature Measurement, Probe Number = 1, T = 20.004000 C 10:41:00 Temperature Measurement, Probe Number = 2, T = 19.979000 C 10:41:01 Temperature Measurement, Probe Number = 3, T = 19.962000 C 10:41:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:41:01 Integrated Voltage Measurement... 10:41:20 Voltage Offset Correction: v_off_ini = 0.000000485 V, v_off_fin = 0.000006187 V 10:41:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419602 Vs 10:41:20 Integrated Voltage Measurement... 10:41:39 Voltage Offset Correction: v_off_ini = 0.000005076 V, v_off_fin = -0.000002647 V 10:41:40 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175300774 Vs 10:41:42 Temperature Measurement, Probe Number = 0, T = 20.307000 C 10:41:43 Temperature Measurement, Probe Number = 1, T = 20.006000 C 10:41:44 Temperature Measurement, Probe Number = 2, T = 19.982000 C 10:41:44 Temperature Measurement, Probe Number = 3, T = 19.965000 C 10:41:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:41:44 Integrated Voltage Measurement... 10:42:03 Voltage Offset Correction: v_off_ini = 0.000001067 V, v_off_fin = 0.000005458 V 10:42:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422795 Vs 10:42:04 Integrated Voltage Measurement... 10:42:23 Voltage Offset Correction: v_off_ini = 0.000004880 V, v_off_fin = -0.000002549 V 10:42:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303735 Vs 10:42:26 Temperature Measurement, Probe Number = 0, T = 20.311000 C 10:42:27 Temperature Measurement, Probe Number = 1, T = 20.006000 C 10:42:27 Temperature Measurement, Probe Number = 2, T = 19.983000 C 10:42:28 Temperature Measurement, Probe Number = 3, T = 19.965000 C 10:42:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:42:28 Integrated Voltage Measurement... 10:42:47 Voltage Offset Correction: v_off_ini = 0.000001212 V, v_off_fin = 0.000005880 V 10:42:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423042 Vs 10:42:48 Integrated Voltage Measurement... 10:43:07 Voltage Offset Correction: v_off_ini = 0.000004855 V, v_off_fin = -0.000001921 V 10:43:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308744 Vs 10:43:10 Temperature Measurement, Probe Number = 0, T = 20.356000 C 10:43:11 Temperature Measurement, Probe Number = 1, T = 20.007000 C 10:43:11 Temperature Measurement, Probe Number = 2, T = 19.983000 C 10:43:12 Temperature Measurement, Probe Number = 3, T = 19.967000 C 10:43:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 10:43:12 Integrated Voltage Measurement... 10:43:31 Voltage Offset Correction: v_off_ini = 0.000001219 V, v_off_fin = 0.000005785 V 10:43:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421800 Vs 10:43:32 Integrated Voltage Measurement... 10:43:51 Voltage Offset Correction: v_off_ini = 0.000004687 V, v_off_fin = -0.000002778 V 10:43:51 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175302833 Vs 10:43:54 Temperature Measurement, Probe Number = 0, T = 20.405000 C 10:43:54 Temperature Measurement, Probe Number = 1, T = 20.008000 C 10:43:55 Temperature Measurement, Probe Number = 2, T = 19.984000 C 10:43:55 Temperature Measurement, Probe Number = 3, T = 19.966000 C 10:43:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 10:43:56 Integrated Voltage Measurement... 10:44:15 Voltage Offset Correction: v_off_ini = 0.000001924 V, v_off_fin = 0.000005905 V 10:44:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422158 Vs 10:44:15 Integrated Voltage Measurement... 10:44:34 Voltage Offset Correction: v_off_ini = 0.000004819 V, v_off_fin = -0.000002578 V 10:44:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299371 Vs 10:44:37 Temperature Measurement, Probe Number = 0, T = 20.453000 C 10:44:38 Temperature Measurement, Probe Number = 1, T = 20.008000 C 10:44:38 Temperature Measurement, Probe Number = 2, T = 19.984000 C 10:44:39 Temperature Measurement, Probe Number = 3, T = 19.965000 C 10:44:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:44:39 Integrated Voltage Measurement... 10:44:59 Voltage Offset Correction: v_off_ini = 0.000000738 V, v_off_fin = 0.000005333 V 10:44:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422294 Vs 10:44:59 Integrated Voltage Measurement... 10:45:19 Voltage Offset Correction: v_off_ini = 0.000004547 V, v_off_fin = -0.000002220 V 10:45:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315235 Vs 10:45:21 Temperature Measurement, Probe Number = 0, T = 20.444000 C 10:45:22 Temperature Measurement, Probe Number = 1, T = 20.008000 C 10:45:23 Temperature Measurement, Probe Number = 2, T = 19.984000 C 10:45:23 Temperature Measurement, Probe Number = 3, T = 19.966000 C 10:45:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 10:45:24 Integrated Voltage Measurement... 10:45:43 Voltage Offset Correction: v_off_ini = 0.000000675 V, v_off_fin = 0.000005351 V 10:45:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414552 Vs 10:45:43 Integrated Voltage Measurement... 10:46:02 Voltage Offset Correction: v_off_ini = 0.000004540 V, v_off_fin = -0.000003389 V 10:46:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316303 Vs 10:46:05 Temperature Measurement, Probe Number = 0, T = 20.445000 C 10:46:06 Temperature Measurement, Probe Number = 1, T = 20.008000 C 10:46:07 Temperature Measurement, Probe Number = 2, T = 19.985000 C 10:46:07 Temperature Measurement, Probe Number = 3, T = 19.966000 C 10:46:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 10:46:08 Integrated Voltage Measurement... 10:46:27 Voltage Offset Correction: v_off_ini = 0.000000943 V, v_off_fin = 0.000005626 V 10:46:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417255 Vs 10:46:27 Integrated Voltage Measurement... 10:46:47 Voltage Offset Correction: v_off_ini = 0.000005294 V, v_off_fin = -0.000003254 V 10:46:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309709 Vs 11:16:49 Temperature Measurement, Probe Number = 0, T = 20.437000 C 11:16:50 Temperature Measurement, Probe Number = 1, T = 20.015000 C 11:16:51 Temperature Measurement, Probe Number = 2, T = 19.988000 C 11:16:52 Temperature Measurement, Probe Number = 3, T = 19.972000 C 11:16:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:16:52 Integrated Voltage Measurement... 11:17:11 Voltage Offset Correction: v_off_ini = 0.000003809 V, v_off_fin = 0.000005126 V 11:17:11 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175517092 Vs 11:17:11 Integrated Voltage Measurement... 11:17:30 Voltage Offset Correction: v_off_ini = 0.000004169 V, v_off_fin = -0.000003100 V 11:17:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301268 Vs 11:17:33 Temperature Measurement, Probe Number = 0, T = 20.425000 C 11:17:34 Temperature Measurement, Probe Number = 1, T = 20.017000 C 11:17:35 Temperature Measurement, Probe Number = 2, T = 19.991000 C 11:17:35 Temperature Measurement, Probe Number = 3, T = 19.972000 C 11:17:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:17:35 Integrated Voltage Measurement... 11:17:55 Voltage Offset Correction: v_off_ini = 0.000000305 V, v_off_fin = 0.000004923 V 11:17:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409157 Vs 11:17:56 Integrated Voltage Measurement... 11:18:15 Voltage Offset Correction: v_off_ini = 0.000004438 V, v_off_fin = -0.000001946 V 11:18:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175296528 Vs 11:18:18 Temperature Measurement, Probe Number = 0, T = 20.428000 C 11:18:19 Temperature Measurement, Probe Number = 1, T = 20.015000 C 11:18:19 Temperature Measurement, Probe Number = 2, T = 19.989000 C 11:18:20 Temperature Measurement, Probe Number = 3, T = 19.972000 C 11:18:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:18:20 Integrated Voltage Measurement... 11:18:39 Voltage Offset Correction: v_off_ini = 0.000001146 V, v_off_fin = 0.000005476 V 11:18:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175413647 Vs 11:18:40 Integrated Voltage Measurement... 11:18:59 Voltage Offset Correction: v_off_ini = 0.000004828 V, v_off_fin = -0.000002256 V 11:18:59 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175298813 Vs 11:19:02 Temperature Measurement, Probe Number = 0, T = 20.431000 C 11:19:02 Temperature Measurement, Probe Number = 1, T = 20.014000 C 11:19:03 Temperature Measurement, Probe Number = 2, T = 19.990000 C 11:19:04 Temperature Measurement, Probe Number = 3, T = 19.971000 C 11:19:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:19:04 Integrated Voltage Measurement... 11:19:23 Voltage Offset Correction: v_off_ini = 0.000001342 V, v_off_fin = 0.000005053 V 11:19:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416437 Vs 11:19:23 Integrated Voltage Measurement... 11:19:43 Voltage Offset Correction: v_off_ini = 0.000004378 V, v_off_fin = -0.000002934 V 11:19:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306341 Vs 11:19:46 Temperature Measurement, Probe Number = 0, T = 20.433000 C 11:19:46 Temperature Measurement, Probe Number = 1, T = 20.016000 C 11:19:47 Temperature Measurement, Probe Number = 2, T = 19.991000 C 11:19:48 Temperature Measurement, Probe Number = 3, T = 19.971000 C 11:19:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:19:48 Integrated Voltage Measurement... 11:20:07 Voltage Offset Correction: v_off_ini = 0.000000581 V, v_off_fin = 0.000005246 V 11:20:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408269 Vs 11:20:07 Integrated Voltage Measurement... 11:20:27 Voltage Offset Correction: v_off_ini = 0.000004027 V, v_off_fin = -0.000002826 V 11:20:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308265 Vs 11:20:30 Temperature Measurement, Probe Number = 0, T = 20.445000 C 11:20:30 Temperature Measurement, Probe Number = 1, T = 20.017000 C 11:20:31 Temperature Measurement, Probe Number = 2, T = 19.994000 C 11:20:31 Temperature Measurement, Probe Number = 3, T = 19.974000 C 11:20:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:20:32 Integrated Voltage Measurement... 11:20:51 Voltage Offset Correction: v_off_ini = 0.000000833 V, v_off_fin = 0.000005187 V 11:20:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412632 Vs 11:20:51 Integrated Voltage Measurement... 11:21:10 Voltage Offset Correction: v_off_ini = 0.000004081 V, v_off_fin = -0.000003376 V 11:21:10 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175308775 Vs 11:21:13 Temperature Measurement, Probe Number = 0, T = 20.440000 C 11:21:14 Temperature Measurement, Probe Number = 1, T = 20.016000 C 11:21:14 Temperature Measurement, Probe Number = 2, T = 19.994000 C 11:21:15 Temperature Measurement, Probe Number = 3, T = 19.978000 C 11:21:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 11:21:15 Integrated Voltage Measurement... 11:21:35 Voltage Offset Correction: v_off_ini = 0.000000571 V, v_off_fin = 0.000005531 V 11:21:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419307 Vs 11:21:35 Integrated Voltage Measurement... 11:21:54 Voltage Offset Correction: v_off_ini = 0.000004362 V, v_off_fin = -0.000002425 V 11:21:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301997 Vs 11:21:57 Temperature Measurement, Probe Number = 0, T = 20.430000 C 11:21:58 Temperature Measurement, Probe Number = 1, T = 20.019000 C 11:21:59 Temperature Measurement, Probe Number = 2, T = 19.994000 C 11:21:59 Temperature Measurement, Probe Number = 3, T = 19.975000 C 11:21:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 11:21:59 Integrated Voltage Measurement... 11:22:19 Voltage Offset Correction: v_off_ini = 0.000001650 V, v_off_fin = 0.000005476 V 11:22:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175421530 Vs 11:22:19 Integrated Voltage Measurement... 11:22:38 Voltage Offset Correction: v_off_ini = 0.000004932 V, v_off_fin = -0.000002784 V 11:22:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294923 Vs 11:22:41 Temperature Measurement, Probe Number = 0, T = 20.463000 C 11:22:42 Temperature Measurement, Probe Number = 1, T = 20.021000 C 11:22:43 Temperature Measurement, Probe Number = 2, T = 19.996000 C 11:22:43 Temperature Measurement, Probe Number = 3, T = 19.973000 C 11:22:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.97 11:22:43 Integrated Voltage Measurement... 11:23:03 Voltage Offset Correction: v_off_ini = 0.000001016 V, v_off_fin = 0.000004975 V 11:23:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415751 Vs 11:23:04 Integrated Voltage Measurement... 11:23:23 Voltage Offset Correction: v_off_ini = 0.000004478 V, v_off_fin = -0.000002502 V 11:23:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304358 Vs 11:23:26 Temperature Measurement, Probe Number = 0, T = 20.482000 C 11:23:27 Temperature Measurement, Probe Number = 1, T = 20.020000 C 11:23:27 Temperature Measurement, Probe Number = 2, T = 19.996000 C 11:23:28 Temperature Measurement, Probe Number = 3, T = 19.975000 C 11:23:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:23:28 Integrated Voltage Measurement... 11:23:47 Voltage Offset Correction: v_off_ini = 0.000000396 V, v_off_fin = 0.000005463 V 11:23:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415606 Vs 11:23:48 Integrated Voltage Measurement... 11:24:07 Voltage Offset Correction: v_off_ini = 0.000004860 V, v_off_fin = -0.000002923 V 11:24:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305969 Vs 11:54:10 Temperature Measurement, Probe Number = 0, T = 20.354000 C 11:54:11 Temperature Measurement, Probe Number = 1, T = 20.023000 C 11:54:11 Temperature Measurement, Probe Number = 2, T = 19.999000 C 11:54:12 Temperature Measurement, Probe Number = 3, T = 19.976000 C 11:54:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:54:12 Integrated Voltage Measurement... 11:54:31 Voltage Offset Correction: v_off_ini = 0.000003648 V, v_off_fin = 0.000005839 V 11:54:31 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175513256 Vs 11:54:32 Integrated Voltage Measurement... 11:54:51 Voltage Offset Correction: v_off_ini = 0.000005053 V, v_off_fin = -0.000002171 V 11:54:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292704 Vs 11:54:54 Temperature Measurement, Probe Number = 0, T = 20.357000 C 11:54:54 Temperature Measurement, Probe Number = 1, T = 20.025000 C 11:54:55 Temperature Measurement, Probe Number = 2, T = 20.000000 C 11:54:56 Temperature Measurement, Probe Number = 3, T = 19.978000 C 11:54:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:54:56 Integrated Voltage Measurement... 11:55:16 Voltage Offset Correction: v_off_ini = 0.000001003 V, v_off_fin = 0.000005223 V 11:55:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410325 Vs 11:55:16 Integrated Voltage Measurement... 11:55:35 Voltage Offset Correction: v_off_ini = 0.000004529 V, v_off_fin = -0.000002807 V 11:55:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292473 Vs 11:55:38 Temperature Measurement, Probe Number = 0, T = 20.376000 C 11:55:39 Temperature Measurement, Probe Number = 1, T = 20.023000 C 11:55:40 Temperature Measurement, Probe Number = 2, T = 20.000000 C 11:55:40 Temperature Measurement, Probe Number = 3, T = 19.979000 C 11:55:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:55:40 Integrated Voltage Measurement... 11:56:00 Voltage Offset Correction: v_off_ini = 0.000001597 V, v_off_fin = 0.000005968 V 11:56:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416181 Vs 11:56:00 Integrated Voltage Measurement... 11:56:19 Voltage Offset Correction: v_off_ini = 0.000004682 V, v_off_fin = -0.000002459 V 11:56:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295541 Vs 11:56:22 Temperature Measurement, Probe Number = 0, T = 20.398000 C 11:56:23 Temperature Measurement, Probe Number = 1, T = 20.023000 C 11:56:23 Temperature Measurement, Probe Number = 2, T = 20.000000 C 11:56:24 Temperature Measurement, Probe Number = 3, T = 19.979000 C 11:56:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:56:24 Integrated Voltage Measurement... 11:56:43 Voltage Offset Correction: v_off_ini = 0.000000804 V, v_off_fin = 0.000005059 V 11:56:44 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175415132 Vs 11:56:44 Integrated Voltage Measurement... 11:57:03 Voltage Offset Correction: v_off_ini = 0.000004609 V, v_off_fin = -0.000003048 V 11:57:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298076 Vs 11:57:06 Temperature Measurement, Probe Number = 0, T = 20.416000 C 11:57:06 Temperature Measurement, Probe Number = 1, T = 20.026000 C 11:57:07 Temperature Measurement, Probe Number = 2, T = 20.003000 C 11:57:08 Temperature Measurement, Probe Number = 3, T = 19.980000 C 11:57:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:57:08 Integrated Voltage Measurement... 11:57:27 Voltage Offset Correction: v_off_ini = -0.000000103 V, v_off_fin = 0.000005028 V 11:57:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409400 Vs 11:57:27 Integrated Voltage Measurement... 11:57:46 Voltage Offset Correction: v_off_ini = 0.000003999 V, v_off_fin = -0.000002904 V 11:57:47 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175298774 Vs 11:57:49 Temperature Measurement, Probe Number = 0, T = 20.408000 C 11:57:50 Temperature Measurement, Probe Number = 1, T = 20.026000 C 11:57:51 Temperature Measurement, Probe Number = 2, T = 20.004000 C 11:57:51 Temperature Measurement, Probe Number = 3, T = 19.979000 C 11:57:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:57:51 Integrated Voltage Measurement... 11:58:10 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000005242 V 11:58:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409009 Vs 11:58:11 Integrated Voltage Measurement... 11:58:30 Voltage Offset Correction: v_off_ini = 0.000004065 V, v_off_fin = -0.000003041 V 11:58:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307658 Vs 11:58:33 Temperature Measurement, Probe Number = 0, T = 20.417000 C 11:58:34 Temperature Measurement, Probe Number = 1, T = 20.026000 C 11:58:34 Temperature Measurement, Probe Number = 2, T = 20.002000 C 11:58:35 Temperature Measurement, Probe Number = 3, T = 19.980000 C 11:58:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:58:35 Integrated Voltage Measurement... 11:58:54 Voltage Offset Correction: v_off_ini = 0.000000813 V, v_off_fin = 0.000005257 V 11:58:55 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175414656 Vs 11:58:55 Integrated Voltage Measurement... 11:59:14 Voltage Offset Correction: v_off_ini = 0.000004849 V, v_off_fin = -0.000002543 V 11:59:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308808 Vs 11:59:17 Temperature Measurement, Probe Number = 0, T = 20.417000 C 11:59:18 Temperature Measurement, Probe Number = 1, T = 20.026000 C 11:59:19 Temperature Measurement, Probe Number = 2, T = 20.002000 C 11:59:19 Temperature Measurement, Probe Number = 3, T = 19.981000 C 11:59:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 11:59:20 Integrated Voltage Measurement... 11:59:39 Voltage Offset Correction: v_off_ini = 0.000000914 V, v_off_fin = 0.000004982 V 11:59:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405757 Vs 11:59:39 Integrated Voltage Measurement... 11:59:58 Voltage Offset Correction: v_off_ini = 0.000004411 V, v_off_fin = -0.000003281 V 11:59:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300465 Vs 12:00:01 Temperature Measurement, Probe Number = 0, T = 20.423000 C 12:00:02 Temperature Measurement, Probe Number = 1, T = 20.026000 C 12:00:03 Temperature Measurement, Probe Number = 2, T = 20.003000 C 12:00:03 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:00:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 12:00:03 Integrated Voltage Measurement... 12:00:23 Voltage Offset Correction: v_off_ini = 0.000000682 V, v_off_fin = 0.000005339 V 12:00:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412169 Vs 12:00:23 Integrated Voltage Measurement... 12:00:42 Voltage Offset Correction: v_off_ini = 0.000004429 V, v_off_fin = -0.000003078 V 12:00:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307689 Vs 12:00:45 Temperature Measurement, Probe Number = 0, T = 20.460000 C 12:00:46 Temperature Measurement, Probe Number = 1, T = 20.026000 C 12:00:46 Temperature Measurement, Probe Number = 2, T = 20.000000 C 12:00:47 Temperature Measurement, Probe Number = 3, T = 19.981000 C 12:00:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 12:00:47 Integrated Voltage Measurement... 12:01:06 Voltage Offset Correction: v_off_ini = 0.000000454 V, v_off_fin = 0.000005655 V 12:01:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175408322 Vs 12:01:07 Integrated Voltage Measurement... 12:01:26 Voltage Offset Correction: v_off_ini = 0.000004883 V, v_off_fin = -0.000002971 V 12:01:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299313 Vs 12:31:29 Temperature Measurement, Probe Number = 0, T = 20.380000 C 12:31:29 Temperature Measurement, Probe Number = 1, T = 20.028000 C 12:31:30 Temperature Measurement, Probe Number = 2, T = 20.006000 C 12:31:30 Temperature Measurement, Probe Number = 3, T = 19.982000 C 12:31:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:31:31 Integrated Voltage Measurement... 12:31:50 Voltage Offset Correction: v_off_ini = 0.000002699 V, v_off_fin = 0.000004566 V 12:31:50 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175515000 Vs 12:31:50 Integrated Voltage Measurement... 12:32:10 Voltage Offset Correction: v_off_ini = 0.000004207 V, v_off_fin = -0.000003193 V 12:32:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292249 Vs 12:32:12 Temperature Measurement, Probe Number = 0, T = 20.380000 C 12:32:13 Temperature Measurement, Probe Number = 1, T = 20.031000 C 12:32:14 Temperature Measurement, Probe Number = 2, T = 20.008000 C 12:32:14 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:32:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:32:15 Integrated Voltage Measurement... 12:32:34 Voltage Offset Correction: v_off_ini = 0.000000925 V, v_off_fin = 0.000005188 V 12:32:34 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405666 Vs 12:32:34 Integrated Voltage Measurement... 12:32:53 Voltage Offset Correction: v_off_ini = 0.000004977 V, v_off_fin = -0.000002638 V 12:32:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292587 Vs 12:32:56 Temperature Measurement, Probe Number = 0, T = 20.397000 C 12:32:57 Temperature Measurement, Probe Number = 1, T = 20.031000 C 12:32:57 Temperature Measurement, Probe Number = 2, T = 20.007000 C 12:32:58 Temperature Measurement, Probe Number = 3, T = 19.983000 C 12:32:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:32:58 Integrated Voltage Measurement... 12:33:18 Voltage Offset Correction: v_off_ini = 0.000001710 V, v_off_fin = 0.000005630 V 12:33:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410430 Vs 12:33:18 Integrated Voltage Measurement... 12:33:37 Voltage Offset Correction: v_off_ini = 0.000004963 V, v_off_fin = -0.000002402 V 12:33:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293239 Vs 12:33:40 Temperature Measurement, Probe Number = 0, T = 20.408000 C 12:33:41 Temperature Measurement, Probe Number = 1, T = 20.032000 C 12:33:42 Temperature Measurement, Probe Number = 2, T = 20.010000 C 12:33:42 Temperature Measurement, Probe Number = 3, T = 19.982000 C 12:33:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:33:42 Integrated Voltage Measurement... 12:34:02 Voltage Offset Correction: v_off_ini = 0.000001155 V, v_off_fin = 0.000005501 V 12:34:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407532 Vs 12:34:02 Integrated Voltage Measurement... 12:34:21 Voltage Offset Correction: v_off_ini = 0.000004597 V, v_off_fin = -0.000003910 V 12:34:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302285 Vs 12:34:24 Temperature Measurement, Probe Number = 0, T = 20.447000 C 12:34:25 Temperature Measurement, Probe Number = 1, T = 20.032000 C 12:34:26 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:34:26 Temperature Measurement, Probe Number = 3, T = 19.985000 C 12:34:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:34:26 Integrated Voltage Measurement... 12:34:46 Voltage Offset Correction: v_off_ini = 0.000000295 V, v_off_fin = 0.000004870 V 12:34:46 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175397135 Vs 12:34:47 Integrated Voltage Measurement... 12:35:06 Voltage Offset Correction: v_off_ini = 0.000004322 V, v_off_fin = -0.000003166 V 12:35:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293420 Vs 12:35:09 Temperature Measurement, Probe Number = 0, T = 20.477000 C 12:35:09 Temperature Measurement, Probe Number = 1, T = 20.033000 C 12:35:10 Temperature Measurement, Probe Number = 2, T = 20.009000 C 12:35:11 Temperature Measurement, Probe Number = 3, T = 19.986000 C 12:35:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:35:11 Integrated Voltage Measurement... 12:35:30 Voltage Offset Correction: v_off_ini = 0.000000573 V, v_off_fin = 0.000004667 V 12:35:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406351 Vs 12:35:30 Integrated Voltage Measurement... 12:35:50 Voltage Offset Correction: v_off_ini = 0.000004418 V, v_off_fin = -0.000002476 V 12:35:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303855 Vs 12:35:53 Temperature Measurement, Probe Number = 0, T = 20.495000 C 12:35:53 Temperature Measurement, Probe Number = 1, T = 20.032000 C 12:35:54 Temperature Measurement, Probe Number = 2, T = 20.008000 C 12:35:54 Temperature Measurement, Probe Number = 3, T = 19.986000 C 12:35:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:35:55 Integrated Voltage Measurement... 12:36:14 Voltage Offset Correction: v_off_ini = 0.000000910 V, v_off_fin = 0.000005451 V 12:36:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406291 Vs 12:36:14 Integrated Voltage Measurement... 12:36:34 Voltage Offset Correction: v_off_ini = 0.000004543 V, v_off_fin = -0.000003900 V 12:36:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302037 Vs 12:36:36 Temperature Measurement, Probe Number = 0, T = 20.454000 C 12:36:37 Temperature Measurement, Probe Number = 1, T = 20.032000 C 12:36:38 Temperature Measurement, Probe Number = 2, T = 20.011000 C 12:36:38 Temperature Measurement, Probe Number = 3, T = 19.984000 C 12:36:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:36:39 Integrated Voltage Measurement... 12:36:58 Voltage Offset Correction: v_off_ini = 0.000000873 V, v_off_fin = 0.000005535 V 12:36:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404617 Vs 12:36:59 Integrated Voltage Measurement... 12:37:18 Voltage Offset Correction: v_off_ini = 0.000004433 V, v_off_fin = -0.000002421 V 12:37:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292521 Vs 12:37:21 Temperature Measurement, Probe Number = 0, T = 20.488000 C 12:37:21 Temperature Measurement, Probe Number = 1, T = 20.032000 C 12:37:22 Temperature Measurement, Probe Number = 2, T = 20.011000 C 12:37:23 Temperature Measurement, Probe Number = 3, T = 19.986000 C 12:37:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 12:37:23 Integrated Voltage Measurement... 12:37:42 Voltage Offset Correction: v_off_ini = 0.000000580 V, v_off_fin = 0.000005405 V 12:37:42 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175412311 Vs 12:37:42 Integrated Voltage Measurement... 12:38:02 Voltage Offset Correction: v_off_ini = 0.000004899 V, v_off_fin = -0.000002683 V 12:38:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302033 Vs 12:38:05 Temperature Measurement, Probe Number = 0, T = 20.481000 C 12:38:05 Temperature Measurement, Probe Number = 1, T = 20.033000 C 12:38:06 Temperature Measurement, Probe Number = 2, T = 20.012000 C 12:38:07 Temperature Measurement, Probe Number = 3, T = 19.985000 C 12:38:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 12:38:07 Integrated Voltage Measurement... 12:38:26 Voltage Offset Correction: v_off_ini = 0.000001102 V, v_off_fin = 0.000005058 V 12:38:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401181 Vs 12:38:26 Integrated Voltage Measurement... 12:38:46 Voltage Offset Correction: v_off_ini = 0.000004294 V, v_off_fin = -0.000002666 V 12:38:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310150 Vs 13:08:49 Temperature Measurement, Probe Number = 0, T = 20.403000 C 13:08:49 Temperature Measurement, Probe Number = 1, T = 20.039000 C 13:08:50 Temperature Measurement, Probe Number = 2, T = 20.012000 C 13:08:51 Temperature Measurement, Probe Number = 3, T = 19.990000 C 13:08:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 13:08:51 Integrated Voltage Measurement... 13:09:10 Voltage Offset Correction: v_off_ini = 0.000003413 V, v_off_fin = 0.000006075 V 13:09:10 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175509905 Vs 13:09:10 Integrated Voltage Measurement... 13:09:30 Voltage Offset Correction: v_off_ini = 0.000004942 V, v_off_fin = -0.000002890 V 13:09:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292536 Vs 13:09:32 Temperature Measurement, Probe Number = 0, T = 20.420000 C 13:09:33 Temperature Measurement, Probe Number = 1, T = 20.039000 C 13:09:34 Temperature Measurement, Probe Number = 2, T = 20.016000 C 13:09:34 Temperature Measurement, Probe Number = 3, T = 19.990000 C 13:09:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:09:35 Integrated Voltage Measurement... 13:09:54 Voltage Offset Correction: v_off_ini = 0.000001032 V, v_off_fin = 0.000005774 V 13:09:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175404993 Vs 13:09:54 Integrated Voltage Measurement... 13:10:13 Voltage Offset Correction: v_off_ini = 0.000004887 V, v_off_fin = -0.000003410 V 13:10:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175286405 Vs 13:10:16 Temperature Measurement, Probe Number = 0, T = 20.387000 C 13:10:17 Temperature Measurement, Probe Number = 1, T = 20.040000 C 13:10:17 Temperature Measurement, Probe Number = 2, T = 20.016000 C 13:10:18 Temperature Measurement, Probe Number = 3, T = 19.992000 C 13:10:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:10:18 Integrated Voltage Measurement... 13:10:37 Voltage Offset Correction: v_off_ini = 0.000000751 V, v_off_fin = 0.000005604 V 13:10:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175399896 Vs 13:10:38 Integrated Voltage Measurement... 13:10:57 Voltage Offset Correction: v_off_ini = 0.000004416 V, v_off_fin = -0.000002400 V 13:10:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291459 Vs 13:11:00 Temperature Measurement, Probe Number = 0, T = 20.422000 C 13:11:00 Temperature Measurement, Probe Number = 1, T = 20.041000 C 13:11:01 Temperature Measurement, Probe Number = 2, T = 20.018000 C 13:11:02 Temperature Measurement, Probe Number = 3, T = 19.994000 C 13:11:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:11:02 Integrated Voltage Measurement... 13:11:21 Voltage Offset Correction: v_off_ini = 0.000000785 V, v_off_fin = 0.000005253 V 13:11:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175398188 Vs 13:11:21 Integrated Voltage Measurement... 13:11:40 Voltage Offset Correction: v_off_ini = 0.000004684 V, v_off_fin = -0.000003135 V 13:11:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290924 Vs 13:11:43 Temperature Measurement, Probe Number = 0, T = 20.417000 C 13:11:44 Temperature Measurement, Probe Number = 1, T = 20.041000 C 13:11:44 Temperature Measurement, Probe Number = 2, T = 20.016000 C 13:11:45 Temperature Measurement, Probe Number = 3, T = 19.994000 C 13:11:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:11:45 Integrated Voltage Measurement... 13:12:04 Voltage Offset Correction: v_off_ini = 0.000000580 V, v_off_fin = 0.000004970 V 13:12:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175395929 Vs 13:12:05 Integrated Voltage Measurement... 13:12:24 Voltage Offset Correction: v_off_ini = 0.000004763 V, v_off_fin = -0.000002875 V 13:12:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294890 Vs 13:12:27 Temperature Measurement, Probe Number = 0, T = 20.474000 C 13:12:27 Temperature Measurement, Probe Number = 1, T = 20.041000 C 13:12:28 Temperature Measurement, Probe Number = 2, T = 20.016000 C 13:12:29 Temperature Measurement, Probe Number = 3, T = 19.995000 C 13:12:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:12:29 Integrated Voltage Measurement... 13:12:48 Voltage Offset Correction: v_off_ini = 0.000000937 V, v_off_fin = 0.000005290 V 13:12:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175400576 Vs 13:12:49 Integrated Voltage Measurement... 13:13:08 Voltage Offset Correction: v_off_ini = 0.000004631 V, v_off_fin = -0.000002568 V 13:13:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292236 Vs 13:13:11 Temperature Measurement, Probe Number = 0, T = 20.473000 C 13:13:12 Temperature Measurement, Probe Number = 1, T = 20.042000 C 13:13:12 Temperature Measurement, Probe Number = 2, T = 20.015000 C 13:13:13 Temperature Measurement, Probe Number = 3, T = 19.995000 C 13:13:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:13:13 Integrated Voltage Measurement... 13:13:32 Voltage Offset Correction: v_off_ini = -0.000000360 V, v_off_fin = 0.000005724 V 13:13:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399770 Vs 13:13:33 Integrated Voltage Measurement... 13:13:52 Voltage Offset Correction: v_off_ini = 0.000004496 V, v_off_fin = -0.000002739 V 13:13:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296070 Vs 13:13:55 Temperature Measurement, Probe Number = 0, T = 20.470000 C 13:13:55 Temperature Measurement, Probe Number = 1, T = 20.040000 C 13:13:56 Temperature Measurement, Probe Number = 2, T = 20.016000 C 13:13:57 Temperature Measurement, Probe Number = 3, T = 19.991000 C 13:13:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:13:57 Integrated Voltage Measurement... 13:14:16 Voltage Offset Correction: v_off_ini = 0.000000890 V, v_off_fin = 0.000004856 V 13:14:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396907 Vs 13:14:17 Integrated Voltage Measurement... 13:14:36 Voltage Offset Correction: v_off_ini = 0.000004604 V, v_off_fin = -0.000002888 V 13:14:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175286602 Vs 13:14:39 Temperature Measurement, Probe Number = 0, T = 20.436000 C 13:14:39 Temperature Measurement, Probe Number = 1, T = 20.039000 C 13:14:40 Temperature Measurement, Probe Number = 2, T = 20.017000 C 13:14:41 Temperature Measurement, Probe Number = 3, T = 19.992000 C 13:14:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:14:41 Integrated Voltage Measurement... 13:15:00 Voltage Offset Correction: v_off_ini = 0.000001060 V, v_off_fin = 0.000004853 V 13:15:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175398475 Vs 13:15:00 Integrated Voltage Measurement... 13:15:20 Voltage Offset Correction: v_off_ini = 0.000003999 V, v_off_fin = -0.000002774 V 13:15:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289035 Vs 13:15:22 Temperature Measurement, Probe Number = 0, T = 20.402000 C 13:15:23 Temperature Measurement, Probe Number = 1, T = 20.038000 C 13:15:24 Temperature Measurement, Probe Number = 2, T = 20.015000 C 13:15:24 Temperature Measurement, Probe Number = 3, T = 19.990000 C 13:15:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 13:15:25 Integrated Voltage Measurement... 13:15:44 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000005094 V 13:15:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400551 Vs 13:15:44 Integrated Voltage Measurement... 13:16:03 Voltage Offset Correction: v_off_ini = 0.000004842 V, v_off_fin = -0.000002853 V 13:16:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293697 Vs 13:46:06 Temperature Measurement, Probe Number = 0, T = 20.354000 C 13:46:07 Temperature Measurement, Probe Number = 1, T = 20.045000 C 13:46:08 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:46:08 Temperature Measurement, Probe Number = 3, T = 19.999000 C 13:46:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:46:08 Integrated Voltage Measurement... 13:46:27 Voltage Offset Correction: v_off_ini = 0.000002279 V, v_off_fin = 0.000004898 V 13:46:28 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175490503 Vs 13:46:28 Integrated Voltage Measurement... 13:46:47 Voltage Offset Correction: v_off_ini = 0.000004327 V, v_off_fin = -0.000003136 V 13:46:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290022 Vs 13:46:50 Temperature Measurement, Probe Number = 0, T = 20.390000 C 13:46:51 Temperature Measurement, Probe Number = 1, T = 20.048000 C 13:46:51 Temperature Measurement, Probe Number = 2, T = 20.027000 C 13:46:52 Temperature Measurement, Probe Number = 3, T = 20.002000 C 13:46:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:46:52 Integrated Voltage Measurement... 13:47:11 Voltage Offset Correction: v_off_ini = -0.000000274 V, v_off_fin = 0.000004845 V 13:47:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175391793 Vs 13:47:12 Integrated Voltage Measurement... 13:47:31 Voltage Offset Correction: v_off_ini = 0.000004154 V, v_off_fin = -0.000002919 V 13:47:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294154 Vs 13:47:34 Temperature Measurement, Probe Number = 0, T = 20.454000 C 13:47:35 Temperature Measurement, Probe Number = 1, T = 20.048000 C 13:47:35 Temperature Measurement, Probe Number = 2, T = 20.027000 C 13:47:36 Temperature Measurement, Probe Number = 3, T = 20.002000 C 13:47:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:47:36 Integrated Voltage Measurement... 13:47:55 Voltage Offset Correction: v_off_ini = 0.000000731 V, v_off_fin = 0.000005400 V 13:47:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175401697 Vs 13:47:56 Integrated Voltage Measurement... 13:48:16 Voltage Offset Correction: v_off_ini = 0.000004560 V, v_off_fin = -0.000001721 V 13:48:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285019 Vs 13:48:19 Temperature Measurement, Probe Number = 0, T = 20.422000 C 13:48:19 Temperature Measurement, Probe Number = 1, T = 20.046000 C 13:48:20 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:48:21 Temperature Measurement, Probe Number = 3, T = 20.000000 C 13:48:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:48:21 Integrated Voltage Measurement... 13:48:40 Voltage Offset Correction: v_off_ini = 0.000001640 V, v_off_fin = 0.000005599 V 13:48:40 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175393653 Vs 13:48:40 Integrated Voltage Measurement... 13:48:59 Voltage Offset Correction: v_off_ini = 0.000004815 V, v_off_fin = -0.000003811 V 13:49:00 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175294464 Vs 13:49:02 Temperature Measurement, Probe Number = 0, T = 20.416000 C 13:49:03 Temperature Measurement, Probe Number = 1, T = 20.047000 C 13:49:04 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:49:04 Temperature Measurement, Probe Number = 3, T = 20.001000 C 13:49:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.42 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:49:04 Integrated Voltage Measurement... 13:49:24 Voltage Offset Correction: v_off_ini = 0.000000773 V, v_off_fin = 0.000005313 V 13:49:25 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406307 Vs 13:49:25 Integrated Voltage Measurement... 13:49:44 Voltage Offset Correction: v_off_ini = 0.000004833 V, v_off_fin = -0.000003320 V 13:49:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285428 Vs 13:49:47 Temperature Measurement, Probe Number = 0, T = 20.443000 C 13:49:48 Temperature Measurement, Probe Number = 1, T = 20.050000 C 13:49:48 Temperature Measurement, Probe Number = 2, T = 20.027000 C 13:49:49 Temperature Measurement, Probe Number = 3, T = 20.003000 C 13:49:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.44 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:49:49 Integrated Voltage Measurement... 13:50:08 Voltage Offset Correction: v_off_ini = 0.000000956 V, v_off_fin = 0.000005771 V 13:50:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175403551 Vs 13:50:08 Integrated Voltage Measurement... 13:50:28 Voltage Offset Correction: v_off_ini = 0.000004891 V, v_off_fin = -0.000002882 V 13:50:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175289381 Vs 13:50:31 Temperature Measurement, Probe Number = 0, T = 20.480000 C 13:50:31 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:50:32 Temperature Measurement, Probe Number = 2, T = 20.025000 C 13:50:33 Temperature Measurement, Probe Number = 3, T = 20.001000 C 13:50:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:50:33 Integrated Voltage Measurement... 13:50:52 Voltage Offset Correction: v_off_ini = 0.000001768 V, v_off_fin = 0.000005949 V 13:50:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410638 Vs 13:50:52 Integrated Voltage Measurement... 13:51:12 Voltage Offset Correction: v_off_ini = 0.000005154 V, v_off_fin = -0.000002243 V 13:51:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284072 Vs 13:51:15 Temperature Measurement, Probe Number = 0, T = 20.497000 C 13:51:16 Temperature Measurement, Probe Number = 1, T = 20.050000 C 13:51:16 Temperature Measurement, Probe Number = 2, T = 20.024000 C 13:51:17 Temperature Measurement, Probe Number = 3, T = 20.001000 C 13:51:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 13:51:17 Integrated Voltage Measurement... 13:51:36 Voltage Offset Correction: v_off_ini = 0.000001363 V, v_off_fin = 0.000005110 V 13:51:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175393609 Vs 13:51:36 Integrated Voltage Measurement... 13:51:56 Voltage Offset Correction: v_off_ini = 0.000004346 V, v_off_fin = -0.000002838 V 13:51:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291956 Vs 13:51:59 Temperature Measurement, Probe Number = 0, T = 20.475000 C 13:51:59 Temperature Measurement, Probe Number = 1, T = 20.049000 C 13:52:00 Temperature Measurement, Probe Number = 2, T = 20.028000 C 13:52:01 Temperature Measurement, Probe Number = 3, T = 20.002000 C 13:52:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.48 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:52:01 Integrated Voltage Measurement... 13:52:20 Voltage Offset Correction: v_off_ini = 0.000000823 V, v_off_fin = 0.000005324 V 13:52:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175398649 Vs 13:52:20 Integrated Voltage Measurement... 13:52:40 Voltage Offset Correction: v_off_ini = 0.000004734 V, v_off_fin = -0.000002354 V 13:52:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292845 Vs 13:52:43 Temperature Measurement, Probe Number = 0, T = 20.446000 C 13:52:43 Temperature Measurement, Probe Number = 1, T = 20.050000 C 13:52:44 Temperature Measurement, Probe Number = 2, T = 20.028000 C 13:52:45 Temperature Measurement, Probe Number = 3, T = 20.003000 C 13:52:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 13:52:45 Integrated Voltage Measurement... 13:53:04 Voltage Offset Correction: v_off_ini = 0.000000680 V, v_off_fin = 0.000006151 V 13:53:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405262 Vs 13:53:04 Integrated Voltage Measurement... 13:53:24 Voltage Offset Correction: v_off_ini = 0.000005568 V, v_off_fin = -0.000002537 V 13:53:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284528 Vs 14:23:27 Temperature Measurement, Probe Number = 0, T = 20.458000 C 14:23:28 Temperature Measurement, Probe Number = 1, T = 20.055000 C 14:23:28 Temperature Measurement, Probe Number = 2, T = 20.034000 C 14:23:29 Temperature Measurement, Probe Number = 3, T = 20.007000 C 14:23:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 14:23:29 Integrated Voltage Measurement... 14:23:49 Voltage Offset Correction: v_off_ini = 0.000003272 V, v_off_fin = 0.000005506 V 14:23:49 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175504734 Vs 14:23:49 Integrated Voltage Measurement... 14:24:08 Voltage Offset Correction: v_off_ini = 0.000004603 V, v_off_fin = -0.000002981 V 14:24:08 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175287620 Vs 14:24:11 Temperature Measurement, Probe Number = 0, T = 20.449000 C 14:24:12 Temperature Measurement, Probe Number = 1, T = 20.059000 C 14:24:12 Temperature Measurement, Probe Number = 2, T = 20.037000 C 14:24:13 Temperature Measurement, Probe Number = 3, T = 20.009000 C 14:24:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:24:13 Integrated Voltage Measurement... 14:24:32 Voltage Offset Correction: v_off_ini = 0.000001440 V, v_off_fin = 0.000005527 V 14:24:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405970 Vs 14:24:32 Integrated Voltage Measurement... 14:24:52 Voltage Offset Correction: v_off_ini = 0.000004584 V, v_off_fin = -0.000002745 V 14:24:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290136 Vs 14:24:55 Temperature Measurement, Probe Number = 0, T = 20.458000 C 14:24:55 Temperature Measurement, Probe Number = 1, T = 20.060000 C 14:24:56 Temperature Measurement, Probe Number = 2, T = 20.037000 C 14:24:57 Temperature Measurement, Probe Number = 3, T = 20.010000 C 14:24:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:24:57 Integrated Voltage Measurement... 14:25:16 Voltage Offset Correction: v_off_ini = 0.000000840 V, v_off_fin = 0.000005545 V 14:25:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175402337 Vs 14:25:16 Integrated Voltage Measurement... 14:25:36 Voltage Offset Correction: v_off_ini = 0.000003582 V, v_off_fin = -0.000002481 V 14:25:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297504 Vs 14:25:39 Temperature Measurement, Probe Number = 0, T = 20.509000 C 14:25:39 Temperature Measurement, Probe Number = 1, T = 20.058000 C 14:25:40 Temperature Measurement, Probe Number = 2, T = 20.037000 C 14:25:41 Temperature Measurement, Probe Number = 3, T = 20.010000 C 14:25:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:25:41 Integrated Voltage Measurement... 14:26:00 Voltage Offset Correction: v_off_ini = 0.000001439 V, v_off_fin = 0.000005655 V 14:26:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405699 Vs 14:26:00 Integrated Voltage Measurement... 14:26:20 Voltage Offset Correction: v_off_ini = 0.000005098 V, v_off_fin = -0.000003205 V 14:26:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289431 Vs 14:26:23 Temperature Measurement, Probe Number = 0, T = 20.460000 C 14:26:23 Temperature Measurement, Probe Number = 1, T = 20.058000 C 14:26:24 Temperature Measurement, Probe Number = 2, T = 20.039000 C 14:26:25 Temperature Measurement, Probe Number = 3, T = 20.009000 C 14:26:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:26:25 Integrated Voltage Measurement... 14:26:44 Voltage Offset Correction: v_off_ini = 0.000000715 V, v_off_fin = 0.000004918 V 14:26:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396690 Vs 14:26:44 Integrated Voltage Measurement... 14:27:04 Voltage Offset Correction: v_off_ini = 0.000004211 V, v_off_fin = -0.000003683 V 14:27:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302223 Vs 14:27:07 Temperature Measurement, Probe Number = 0, T = 20.501000 C 14:27:07 Temperature Measurement, Probe Number = 1, T = 20.058000 C 14:27:08 Temperature Measurement, Probe Number = 2, T = 20.038000 C 14:27:09 Temperature Measurement, Probe Number = 3, T = 20.010000 C 14:27:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:27:09 Integrated Voltage Measurement... 14:27:28 Voltage Offset Correction: v_off_ini = 0.000000486 V, v_off_fin = 0.000005427 V 14:27:28 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175405728 Vs 14:27:28 Integrated Voltage Measurement... 14:27:47 Voltage Offset Correction: v_off_ini = 0.000004466 V, v_off_fin = -0.000003062 V 14:27:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289510 Vs 14:27:50 Temperature Measurement, Probe Number = 0, T = 20.511000 C 14:27:51 Temperature Measurement, Probe Number = 1, T = 20.060000 C 14:27:52 Temperature Measurement, Probe Number = 2, T = 20.039000 C 14:27:52 Temperature Measurement, Probe Number = 3, T = 20.012000 C 14:27:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.51 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:27:52 Integrated Voltage Measurement... 14:28:12 Voltage Offset Correction: v_off_ini = 0.000000392 V, v_off_fin = 0.000004388 V 14:28:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401521 Vs 14:28:12 Integrated Voltage Measurement... 14:28:31 Voltage Offset Correction: v_off_ini = 0.000003833 V, v_off_fin = -0.000003547 V 14:28:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299098 Vs 14:28:34 Temperature Measurement, Probe Number = 0, T = 20.465000 C 14:28:35 Temperature Measurement, Probe Number = 1, T = 20.060000 C 14:28:35 Temperature Measurement, Probe Number = 2, T = 20.040000 C 14:28:36 Temperature Measurement, Probe Number = 3, T = 20.013000 C 14:28:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.46 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:28:36 Integrated Voltage Measurement... 14:28:56 Voltage Offset Correction: v_off_ini = 0.000001301 V, v_off_fin = 0.000005421 V 14:28:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409959 Vs 14:28:56 Integrated Voltage Measurement... 14:29:15 Voltage Offset Correction: v_off_ini = 0.000004729 V, v_off_fin = -0.000002708 V 14:29:16 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289365 Vs 14:29:18 Temperature Measurement, Probe Number = 0, T = 20.473000 C 14:29:19 Temperature Measurement, Probe Number = 1, T = 20.063000 C 14:29:20 Temperature Measurement, Probe Number = 2, T = 20.042000 C 14:29:20 Temperature Measurement, Probe Number = 3, T = 20.013000 C 14:29:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.47 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:29:21 Integrated Voltage Measurement... 14:29:40 Voltage Offset Correction: v_off_ini = 0.000000699 V, v_off_fin = 0.000005265 V 14:29:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175408305 Vs 14:29:40 Integrated Voltage Measurement... 14:29:59 Voltage Offset Correction: v_off_ini = 0.000004376 V, v_off_fin = -0.000002113 V 14:29:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292132 Vs 14:30:02 Temperature Measurement, Probe Number = 0, T = 20.503000 C 14:30:03 Temperature Measurement, Probe Number = 1, T = 20.063000 C 14:30:03 Temperature Measurement, Probe Number = 2, T = 20.043000 C 14:30:04 Temperature Measurement, Probe Number = 3, T = 20.014000 C 14:30:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.50 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 14:30:04 Integrated Voltage Measurement... 14:30:24 Voltage Offset Correction: v_off_ini = 0.000000955 V, v_off_fin = 0.000005473 V 14:30:24 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415437 Vs 14:30:24 Integrated Voltage Measurement... 14:30:43 Voltage Offset Correction: v_off_ini = 0.000004850 V, v_off_fin = -0.000002259 V 14:30:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292003 Vs 15:00:46 Temperature Measurement, Probe Number = 0, T = 20.312000 C 15:00:47 Temperature Measurement, Probe Number = 1, T = 20.061000 C 15:00:47 Temperature Measurement, Probe Number = 2, T = 20.036000 C 15:00:48 Temperature Measurement, Probe Number = 3, T = 20.012000 C 15:00:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:00:48 Integrated Voltage Measurement... 15:01:07 Voltage Offset Correction: v_off_ini = 0.000003487 V, v_off_fin = 0.000005256 V 15:01:08 Integrated Voltage Measurement Delta Gap = 0.0040028 m VT = 0.175485484 Vs 15:01:08 Integrated Voltage Measurement... 15:01:27 Voltage Offset Correction: v_off_ini = 0.000004493 V, v_off_fin = -0.000003211 V 15:01:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302147 Vs 15:01:30 Temperature Measurement, Probe Number = 0, T = 20.325000 C 15:01:31 Temperature Measurement, Probe Number = 1, T = 20.062000 C 15:01:31 Temperature Measurement, Probe Number = 2, T = 20.036000 C 15:01:32 Temperature Measurement, Probe Number = 3, T = 20.012000 C 15:01:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:01:32 Integrated Voltage Measurement... 15:01:51 Voltage Offset Correction: v_off_ini = 0.000001195 V, v_off_fin = 0.000005313 V 15:01:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411198 Vs 15:01:52 Integrated Voltage Measurement... 15:02:11 Voltage Offset Correction: v_off_ini = 0.000004463 V, v_off_fin = -0.000002761 V 15:02:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307205 Vs 15:02:14 Temperature Measurement, Probe Number = 0, T = 20.302000 C 15:02:15 Temperature Measurement, Probe Number = 1, T = 20.064000 C 15:02:15 Temperature Measurement, Probe Number = 2, T = 20.039000 C 15:02:16 Temperature Measurement, Probe Number = 3, T = 20.015000 C 15:02:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:02:16 Integrated Voltage Measurement... 15:02:35 Voltage Offset Correction: v_off_ini = 0.000001350 V, v_off_fin = 0.000005548 V 15:02:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416484 Vs 15:02:36 Integrated Voltage Measurement... 15:02:55 Voltage Offset Correction: v_off_ini = 0.000004420 V, v_off_fin = -0.000002907 V 15:02:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308549 Vs 15:02:58 Temperature Measurement, Probe Number = 0, T = 20.296000 C 15:02:59 Temperature Measurement, Probe Number = 1, T = 20.065000 C 15:02:59 Temperature Measurement, Probe Number = 2, T = 20.040000 C 15:03:00 Temperature Measurement, Probe Number = 3, T = 20.015000 C 15:03:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:03:00 Integrated Voltage Measurement... 15:03:19 Voltage Offset Correction: v_off_ini = 0.000001058 V, v_off_fin = 0.000005283 V 15:03:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175414266 Vs 15:03:20 Integrated Voltage Measurement... 15:03:39 Voltage Offset Correction: v_off_ini = 0.000005287 V, v_off_fin = -0.000003444 V 15:03:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306718 Vs 15:03:42 Temperature Measurement, Probe Number = 0, T = 20.334000 C 15:03:43 Temperature Measurement, Probe Number = 1, T = 20.065000 C 15:03:44 Temperature Measurement, Probe Number = 2, T = 20.038000 C 15:03:44 Temperature Measurement, Probe Number = 3, T = 20.013000 C 15:03:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:03:44 Integrated Voltage Measurement... 15:04:04 Voltage Offset Correction: v_off_ini = 0.000000862 V, v_off_fin = 0.000005230 V 15:04:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413170 Vs 15:04:04 Integrated Voltage Measurement... 15:04:23 Voltage Offset Correction: v_off_ini = 0.000004506 V, v_off_fin = -0.000003091 V 15:04:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305430 Vs 15:04:26 Temperature Measurement, Probe Number = 0, T = 20.347000 C 15:04:27 Temperature Measurement, Probe Number = 1, T = 20.065000 C 15:04:27 Temperature Measurement, Probe Number = 2, T = 20.037000 C 15:04:28 Temperature Measurement, Probe Number = 3, T = 20.015000 C 15:04:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.02 15:04:28 Integrated Voltage Measurement... 15:04:47 Voltage Offset Correction: v_off_ini = 0.000000685 V, v_off_fin = 0.000005145 V 15:04:48 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415470 Vs 15:04:48 Integrated Voltage Measurement... 15:05:07 Voltage Offset Correction: v_off_ini = 0.000004431 V, v_off_fin = -0.000003262 V 15:05:07 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175305211 Vs 15:05:09 Temperature Measurement, Probe Number = 0, T = 20.331000 C 15:05:10 Temperature Measurement, Probe Number = 1, T = 20.066000 C 15:05:11 Temperature Measurement, Probe Number = 2, T = 20.037000 C 15:05:11 Temperature Measurement, Probe Number = 3, T = 20.013000 C 15:05:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:05:12 Integrated Voltage Measurement... 15:05:31 Voltage Offset Correction: v_off_ini = 0.000000400 V, v_off_fin = 0.000004813 V 15:05:31 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175415795 Vs 15:05:31 Integrated Voltage Measurement... 15:05:50 Voltage Offset Correction: v_off_ini = 0.000004503 V, v_off_fin = -0.000002764 V 15:05:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304764 Vs 15:05:53 Temperature Measurement, Probe Number = 0, T = 20.300000 C 15:05:54 Temperature Measurement, Probe Number = 1, T = 20.065000 C 15:05:55 Temperature Measurement, Probe Number = 2, T = 20.037000 C 15:05:55 Temperature Measurement, Probe Number = 3, T = 20.013000 C 15:05:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:05:56 Integrated Voltage Measurement... 15:06:15 Voltage Offset Correction: v_off_ini = 0.000001349 V, v_off_fin = 0.000005731 V 15:06:15 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414272 Vs 15:06:15 Integrated Voltage Measurement... 15:06:34 Voltage Offset Correction: v_off_ini = 0.000004809 V, v_off_fin = -0.000002408 V 15:06:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308633 Vs 15:06:37 Temperature Measurement, Probe Number = 0, T = 20.329000 C 15:06:38 Temperature Measurement, Probe Number = 1, T = 20.065000 C 15:06:39 Temperature Measurement, Probe Number = 2, T = 20.037000 C 15:06:39 Temperature Measurement, Probe Number = 3, T = 20.011000 C 15:06:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.07 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:06:40 Integrated Voltage Measurement... 15:06:59 Voltage Offset Correction: v_off_ini = 0.000000673 V, v_off_fin = 0.000005023 V 15:06:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175416433 Vs 15:06:59 Integrated Voltage Measurement... 15:07:18 Voltage Offset Correction: v_off_ini = 0.000004523 V, v_off_fin = -0.000002752 V 15:07:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310611 Vs 15:07:21 Temperature Measurement, Probe Number = 0, T = 20.351000 C 15:07:22 Temperature Measurement, Probe Number = 1, T = 20.063000 C 15:07:23 Temperature Measurement, Probe Number = 2, T = 20.034000 C 15:07:23 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:07:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:07:23 Integrated Voltage Measurement... 15:07:43 Voltage Offset Correction: v_off_ini = 0.000000814 V, v_off_fin = 0.000005890 V 15:07:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423183 Vs 15:07:43 Integrated Voltage Measurement... 15:08:03 Voltage Offset Correction: v_off_ini = 0.000004893 V, v_off_fin = -0.000002657 V 15:08:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303329 Vs 15:38:06 Temperature Measurement, Probe Number = 0, T = 20.276000 C 15:38:06 Temperature Measurement, Probe Number = 1, T = 20.053000 C 15:38:07 Temperature Measurement, Probe Number = 2, T = 20.032000 C 15:38:08 Temperature Measurement, Probe Number = 3, T = 20.008000 C 15:38:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:38:08 Integrated Voltage Measurement... 15:38:27 Voltage Offset Correction: v_off_ini = 0.000003303 V, v_off_fin = 0.000005557 V 15:38:27 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175504535 Vs 15:38:27 Integrated Voltage Measurement... 15:38:47 Voltage Offset Correction: v_off_ini = 0.000004741 V, v_off_fin = -0.000001857 V 15:38:47 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304317 Vs 15:38:49 Temperature Measurement, Probe Number = 0, T = 20.248000 C 15:38:50 Temperature Measurement, Probe Number = 1, T = 20.057000 C 15:38:51 Temperature Measurement, Probe Number = 2, T = 20.034000 C 15:38:51 Temperature Measurement, Probe Number = 3, T = 20.008000 C 15:38:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:38:52 Integrated Voltage Measurement... 15:39:11 Voltage Offset Correction: v_off_ini = 0.000000859 V, v_off_fin = 0.000005280 V 15:39:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410621 Vs 15:39:11 Integrated Voltage Measurement... 15:39:31 Voltage Offset Correction: v_off_ini = 0.000004523 V, v_off_fin = -0.000002730 V 15:39:31 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313324 Vs 15:39:34 Temperature Measurement, Probe Number = 0, T = 20.250000 C 15:39:34 Temperature Measurement, Probe Number = 1, T = 20.057000 C 15:39:35 Temperature Measurement, Probe Number = 2, T = 20.035000 C 15:39:36 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:39:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 15:39:36 Integrated Voltage Measurement... 15:39:55 Voltage Offset Correction: v_off_ini = 0.000001461 V, v_off_fin = 0.000005159 V 15:39:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407160 Vs 15:39:55 Integrated Voltage Measurement... 15:40:15 Voltage Offset Correction: v_off_ini = 0.000005000 V, v_off_fin = -0.000001911 V 15:40:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299922 Vs 15:40:18 Temperature Measurement, Probe Number = 0, T = 20.319000 C 15:40:18 Temperature Measurement, Probe Number = 1, T = 20.055000 C 15:40:19 Temperature Measurement, Probe Number = 2, T = 20.031000 C 15:40:20 Temperature Measurement, Probe Number = 3, T = 20.008000 C 15:40:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:40:20 Integrated Voltage Measurement... 15:40:39 Voltage Offset Correction: v_off_ini = 0.000001185 V, v_off_fin = 0.000005143 V 15:40:39 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175413237 Vs 15:40:40 Integrated Voltage Measurement... 15:40:59 Voltage Offset Correction: v_off_ini = 0.000004312 V, v_off_fin = -0.000002809 V 15:40:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305244 Vs 15:41:01 Temperature Measurement, Probe Number = 0, T = 20.266000 C 15:41:02 Temperature Measurement, Probe Number = 1, T = 20.054000 C 15:41:03 Temperature Measurement, Probe Number = 2, T = 20.030000 C 15:41:03 Temperature Measurement, Probe Number = 3, T = 20.005000 C 15:41:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 15:41:04 Integrated Voltage Measurement... 15:41:23 Voltage Offset Correction: v_off_ini = 0.000000336 V, v_off_fin = 0.000004661 V 15:41:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415877 Vs 15:41:23 Integrated Voltage Measurement... 15:41:43 Voltage Offset Correction: v_off_ini = 0.000004385 V, v_off_fin = -0.000001710 V 15:41:43 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315388 Vs 15:41:46 Temperature Measurement, Probe Number = 0, T = 20.262000 C 15:41:47 Temperature Measurement, Probe Number = 1, T = 20.055000 C 15:41:47 Temperature Measurement, Probe Number = 2, T = 20.029000 C 15:41:48 Temperature Measurement, Probe Number = 3, T = 20.006000 C 15:41:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:41:48 Integrated Voltage Measurement... 15:42:07 Voltage Offset Correction: v_off_ini = 0.000001749 V, v_off_fin = 0.000005322 V 15:42:07 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175409956 Vs 15:42:07 Integrated Voltage Measurement... 15:42:27 Voltage Offset Correction: v_off_ini = 0.000004250 V, v_off_fin = -0.000002548 V 15:42:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307195 Vs 15:42:30 Temperature Measurement, Probe Number = 0, T = 20.344000 C 15:42:30 Temperature Measurement, Probe Number = 1, T = 20.056000 C 15:42:31 Temperature Measurement, Probe Number = 2, T = 20.029000 C 15:42:32 Temperature Measurement, Probe Number = 3, T = 20.006000 C 15:42:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:42:32 Integrated Voltage Measurement... 15:42:51 Voltage Offset Correction: v_off_ini = 0.000001329 V, v_off_fin = 0.000005358 V 15:42:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419626 Vs 15:42:52 Integrated Voltage Measurement... 15:43:11 Voltage Offset Correction: v_off_ini = 0.000005044 V, v_off_fin = -0.000002430 V 15:43:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314751 Vs 15:43:14 Temperature Measurement, Probe Number = 0, T = 20.376000 C 15:43:14 Temperature Measurement, Probe Number = 1, T = 20.056000 C 15:43:15 Temperature Measurement, Probe Number = 2, T = 20.030000 C 15:43:16 Temperature Measurement, Probe Number = 3, T = 20.008000 C 15:43:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:43:16 Integrated Voltage Measurement... 15:43:35 Voltage Offset Correction: v_off_ini = 0.000001184 V, v_off_fin = 0.000005602 V 15:43:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425865 Vs 15:43:36 Integrated Voltage Measurement... 15:43:55 Voltage Offset Correction: v_off_ini = 0.000005208 V, v_off_fin = -0.000003389 V 15:43:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312506 Vs 15:43:58 Temperature Measurement, Probe Number = 0, T = 20.396000 C 15:43:59 Temperature Measurement, Probe Number = 1, T = 20.057000 C 15:43:59 Temperature Measurement, Probe Number = 2, T = 20.031000 C 15:44:00 Temperature Measurement, Probe Number = 3, T = 20.009000 C 15:44:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:44:00 Integrated Voltage Measurement... 15:44:19 Voltage Offset Correction: v_off_ini = 0.000000491 V, v_off_fin = 0.000005020 V 15:44:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415751 Vs 15:44:20 Integrated Voltage Measurement... 15:44:39 Voltage Offset Correction: v_off_ini = 0.000004564 V, v_off_fin = -0.000002360 V 15:44:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313406 Vs 15:44:42 Temperature Measurement, Probe Number = 0, T = 20.370000 C 15:44:43 Temperature Measurement, Probe Number = 1, T = 20.056000 C 15:44:43 Temperature Measurement, Probe Number = 2, T = 20.030000 C 15:44:44 Temperature Measurement, Probe Number = 3, T = 20.008000 C 15:44:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 15:44:44 Integrated Voltage Measurement... 15:45:03 Voltage Offset Correction: v_off_ini = 0.000001307 V, v_off_fin = 0.000005361 V 15:45:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418681 Vs 15:45:04 Integrated Voltage Measurement... 15:45:23 Voltage Offset Correction: v_off_ini = 0.000004553 V, v_off_fin = -0.000002607 V 15:45:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312104 Vs 16:15:26 Temperature Measurement, Probe Number = 0, T = 20.296000 C 16:15:27 Temperature Measurement, Probe Number = 1, T = 20.054000 C 16:15:27 Temperature Measurement, Probe Number = 2, T = 20.026000 C 16:15:28 Temperature Measurement, Probe Number = 3, T = 20.003000 C 16:15:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:15:28 Integrated Voltage Measurement... 16:15:47 Voltage Offset Correction: v_off_ini = 0.000003850 V, v_off_fin = 0.000004896 V 16:15:47 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175508162 Vs 16:15:48 Integrated Voltage Measurement... 16:16:07 Voltage Offset Correction: v_off_ini = 0.000004692 V, v_off_fin = -0.000002418 V 16:16:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309803 Vs 16:16:10 Temperature Measurement, Probe Number = 0, T = 20.260000 C 16:16:10 Temperature Measurement, Probe Number = 1, T = 20.059000 C 16:16:11 Temperature Measurement, Probe Number = 2, T = 20.031000 C 16:16:12 Temperature Measurement, Probe Number = 3, T = 20.008000 C 16:16:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:16:12 Integrated Voltage Measurement... 16:16:31 Voltage Offset Correction: v_off_ini = 0.000001077 V, v_off_fin = 0.000005422 V 16:16:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420172 Vs 16:16:32 Integrated Voltage Measurement... 16:16:51 Voltage Offset Correction: v_off_ini = 0.000004644 V, v_off_fin = -0.000002610 V 16:16:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310849 Vs 16:16:54 Temperature Measurement, Probe Number = 0, T = 20.268000 C 16:16:54 Temperature Measurement, Probe Number = 1, T = 20.060000 C 16:16:55 Temperature Measurement, Probe Number = 2, T = 20.033000 C 16:16:56 Temperature Measurement, Probe Number = 3, T = 20.011000 C 16:16:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:16:56 Integrated Voltage Measurement... 16:17:15 Voltage Offset Correction: v_off_ini = 0.000000677 V, v_off_fin = 0.000005524 V 16:17:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422544 Vs 16:17:15 Integrated Voltage Measurement... 16:17:35 Voltage Offset Correction: v_off_ini = 0.000005000 V, v_off_fin = -0.000002623 V 16:17:35 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307245 Vs 16:17:38 Temperature Measurement, Probe Number = 0, T = 20.303000 C 16:17:38 Temperature Measurement, Probe Number = 1, T = 20.060000 C 16:17:39 Temperature Measurement, Probe Number = 2, T = 20.033000 C 16:17:39 Temperature Measurement, Probe Number = 3, T = 20.006000 C 16:17:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:17:40 Integrated Voltage Measurement... 16:17:59 Voltage Offset Correction: v_off_ini = 0.000000428 V, v_off_fin = 0.000005904 V 16:17:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429572 Vs 16:17:59 Integrated Voltage Measurement... 16:18:19 Voltage Offset Correction: v_off_ini = 0.000004653 V, v_off_fin = -0.000002992 V 16:18:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304656 Vs 16:18:21 Temperature Measurement, Probe Number = 0, T = 20.290000 C 16:18:22 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:18:23 Temperature Measurement, Probe Number = 2, T = 20.035000 C 16:18:23 Temperature Measurement, Probe Number = 3, T = 20.008000 C 16:18:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:18:24 Integrated Voltage Measurement... 16:18:43 Voltage Offset Correction: v_off_ini = 0.000000821 V, v_off_fin = 0.000004883 V 16:18:43 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416361 Vs 16:18:43 Integrated Voltage Measurement... 16:19:02 Voltage Offset Correction: v_off_ini = 0.000004816 V, v_off_fin = -0.000002949 V 16:19:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323566 Vs 16:19:05 Temperature Measurement, Probe Number = 0, T = 20.350000 C 16:19:06 Temperature Measurement, Probe Number = 1, T = 20.062000 C 16:19:07 Temperature Measurement, Probe Number = 2, T = 20.036000 C 16:19:07 Temperature Measurement, Probe Number = 3, T = 20.011000 C 16:19:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:19:08 Integrated Voltage Measurement... 16:19:27 Voltage Offset Correction: v_off_ini = 0.000001405 V, v_off_fin = 0.000005381 V 16:19:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418610 Vs 16:19:27 Integrated Voltage Measurement... 16:19:46 Voltage Offset Correction: v_off_ini = 0.000004269 V, v_off_fin = -0.000002868 V 16:19:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309282 Vs 16:19:49 Temperature Measurement, Probe Number = 0, T = 20.362000 C 16:19:50 Temperature Measurement, Probe Number = 1, T = 20.060000 C 16:19:50 Temperature Measurement, Probe Number = 2, T = 20.031000 C 16:19:51 Temperature Measurement, Probe Number = 3, T = 20.007000 C 16:19:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:19:51 Integrated Voltage Measurement... 16:20:11 Voltage Offset Correction: v_off_ini = 0.000000779 V, v_off_fin = 0.000005462 V 16:20:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424886 Vs 16:20:11 Integrated Voltage Measurement... 16:20:30 Voltage Offset Correction: v_off_ini = 0.000004653 V, v_off_fin = -0.000002969 V 16:20:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306252 Vs 16:20:33 Temperature Measurement, Probe Number = 0, T = 20.364000 C 16:20:34 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:20:35 Temperature Measurement, Probe Number = 2, T = 20.035000 C 16:20:35 Temperature Measurement, Probe Number = 3, T = 20.006000 C 16:20:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.04 P3 = Top 1, Value = 20.01 16:20:35 Integrated Voltage Measurement... 16:20:55 Voltage Offset Correction: v_off_ini = 0.000000964 V, v_off_fin = 0.000005166 V 16:20:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418185 Vs 16:20:55 Integrated Voltage Measurement... 16:21:14 Voltage Offset Correction: v_off_ini = 0.000004642 V, v_off_fin = -0.000002642 V 16:21:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316616 Vs 16:21:17 Temperature Measurement, Probe Number = 0, T = 20.394000 C 16:21:18 Temperature Measurement, Probe Number = 1, T = 20.061000 C 16:21:19 Temperature Measurement, Probe Number = 2, T = 20.029000 C 16:21:19 Temperature Measurement, Probe Number = 3, T = 20.006000 C 16:21:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:21:19 Integrated Voltage Measurement... 16:21:39 Voltage Offset Correction: v_off_ini = 0.000001743 V, v_off_fin = 0.000005331 V 16:21:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430328 Vs 16:21:39 Integrated Voltage Measurement... 16:21:58 Voltage Offset Correction: v_off_ini = 0.000004980 V, v_off_fin = -0.000002670 V 16:21:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317804 Vs 16:22:01 Temperature Measurement, Probe Number = 0, T = 20.411000 C 16:22:02 Temperature Measurement, Probe Number = 1, T = 20.062000 C 16:22:03 Temperature Measurement, Probe Number = 2, T = 20.033000 C 16:22:03 Temperature Measurement, Probe Number = 3, T = 20.008000 C 16:22:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.06 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:22:03 Integrated Voltage Measurement... 16:22:23 Voltage Offset Correction: v_off_ini = 0.000001131 V, v_off_fin = 0.000005845 V 16:22:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425640 Vs 16:22:23 Integrated Voltage Measurement... 16:22:42 Voltage Offset Correction: v_off_ini = 0.000005053 V, v_off_fin = -0.000002710 V 16:22:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314254 Vs 16:52:45 Temperature Measurement, Probe Number = 0, T = 20.206000 C 16:52:46 Temperature Measurement, Probe Number = 1, T = 20.049000 C 16:52:47 Temperature Measurement, Probe Number = 2, T = 20.019000 C 16:52:48 Temperature Measurement, Probe Number = 3, T = 20.001000 C 16:52:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 16:52:48 Integrated Voltage Measurement... 16:53:07 Voltage Offset Correction: v_off_ini = 0.000004188 V, v_off_fin = 0.000005880 V 16:53:07 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175518523 Vs 16:53:07 Integrated Voltage Measurement... 16:53:26 Voltage Offset Correction: v_off_ini = 0.000005458 V, v_off_fin = -0.000002352 V 16:53:27 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309369 Vs 16:53:29 Temperature Measurement, Probe Number = 0, T = 20.246000 C 16:53:30 Temperature Measurement, Probe Number = 1, T = 20.051000 C 16:53:31 Temperature Measurement, Probe Number = 2, T = 20.025000 C 16:53:31 Temperature Measurement, Probe Number = 3, T = 20.005000 C 16:53:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 16:53:31 Integrated Voltage Measurement... 16:53:51 Voltage Offset Correction: v_off_ini = 0.000000977 V, v_off_fin = 0.000005699 V 16:53:51 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429509 Vs 16:53:51 Integrated Voltage Measurement... 16:54:10 Voltage Offset Correction: v_off_ini = 0.000005078 V, v_off_fin = -0.000002413 V 16:54:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318539 Vs 16:54:13 Temperature Measurement, Probe Number = 0, T = 20.254000 C 16:54:14 Temperature Measurement, Probe Number = 1, T = 20.055000 C 16:54:15 Temperature Measurement, Probe Number = 2, T = 20.027000 C 16:54:15 Temperature Measurement, Probe Number = 3, T = 20.006000 C 16:54:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:54:15 Integrated Voltage Measurement... 16:54:35 Voltage Offset Correction: v_off_ini = 0.000001415 V, v_off_fin = 0.000005883 V 16:54:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438236 Vs 16:54:35 Integrated Voltage Measurement... 16:54:54 Voltage Offset Correction: v_off_ini = 0.000004920 V, v_off_fin = -0.000002552 V 16:54:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312803 Vs 16:54:57 Temperature Measurement, Probe Number = 0, T = 20.252000 C 16:54:58 Temperature Measurement, Probe Number = 1, T = 20.052000 C 16:54:58 Temperature Measurement, Probe Number = 2, T = 20.024000 C 16:54:59 Temperature Measurement, Probe Number = 3, T = 20.003000 C 16:54:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 16:54:59 Integrated Voltage Measurement... 16:55:18 Voltage Offset Correction: v_off_ini = 0.000001251 V, v_off_fin = 0.000005303 V 16:55:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439298 Vs 16:55:19 Integrated Voltage Measurement... 16:55:38 Voltage Offset Correction: v_off_ini = 0.000004648 V, v_off_fin = -0.000002516 V 16:55:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311131 Vs 16:55:41 Temperature Measurement, Probe Number = 0, T = 20.291000 C 16:55:41 Temperature Measurement, Probe Number = 1, T = 20.049000 C 16:55:42 Temperature Measurement, Probe Number = 2, T = 20.024000 C 16:55:43 Temperature Measurement, Probe Number = 3, T = 20.002000 C 16:55:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 16:55:43 Integrated Voltage Measurement... 16:56:02 Voltage Offset Correction: v_off_ini = 0.000001320 V, v_off_fin = 0.000005124 V 16:56:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433862 Vs 16:56:02 Integrated Voltage Measurement... 16:56:21 Voltage Offset Correction: v_off_ini = 0.000005115 V, v_off_fin = -0.000002594 V 16:56:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317129 Vs 16:56:24 Temperature Measurement, Probe Number = 0, T = 20.303000 C 16:56:25 Temperature Measurement, Probe Number = 1, T = 20.052000 C 16:56:26 Temperature Measurement, Probe Number = 2, T = 20.027000 C 16:56:26 Temperature Measurement, Probe Number = 3, T = 20.004000 C 16:56:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:56:26 Integrated Voltage Measurement... 16:56:45 Voltage Offset Correction: v_off_ini = 0.000000987 V, v_off_fin = 0.000005533 V 16:56:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434503 Vs 16:56:46 Integrated Voltage Measurement... 16:57:05 Voltage Offset Correction: v_off_ini = 0.000004699 V, v_off_fin = -0.000002657 V 16:57:05 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314641 Vs 16:57:08 Temperature Measurement, Probe Number = 0, T = 20.310000 C 16:57:08 Temperature Measurement, Probe Number = 1, T = 20.053000 C 16:57:09 Temperature Measurement, Probe Number = 2, T = 20.028000 C 16:57:09 Temperature Measurement, Probe Number = 3, T = 20.006000 C 16:57:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.01 16:57:10 Integrated Voltage Measurement... 16:57:30 Voltage Offset Correction: v_off_ini = 0.000001003 V, v_off_fin = 0.000005848 V 16:57:30 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175439863 Vs 16:57:30 Integrated Voltage Measurement... 16:57:49 Voltage Offset Correction: v_off_ini = 0.000004424 V, v_off_fin = -0.000002856 V 16:57:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318031 Vs 16:57:52 Temperature Measurement, Probe Number = 0, T = 20.347000 C 16:57:53 Temperature Measurement, Probe Number = 1, T = 20.053000 C 16:57:53 Temperature Measurement, Probe Number = 2, T = 20.028000 C 16:57:54 Temperature Measurement, Probe Number = 3, T = 20.005000 C 16:57:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:57:54 Integrated Voltage Measurement... 16:58:13 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = 0.000005626 V 16:58:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434048 Vs 16:58:13 Integrated Voltage Measurement... 16:58:33 Voltage Offset Correction: v_off_ini = 0.000005100 V, v_off_fin = -0.000002776 V 16:58:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320976 Vs 16:58:36 Temperature Measurement, Probe Number = 0, T = 20.341000 C 16:58:36 Temperature Measurement, Probe Number = 1, T = 20.049000 C 16:58:37 Temperature Measurement, Probe Number = 2, T = 20.025000 C 16:58:38 Temperature Measurement, Probe Number = 3, T = 20.002000 C 16:58:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 16:58:38 Integrated Voltage Measurement... 16:58:57 Voltage Offset Correction: v_off_ini = 0.000000878 V, v_off_fin = 0.000005494 V 16:58:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432747 Vs 16:58:57 Integrated Voltage Measurement... 16:59:16 Voltage Offset Correction: v_off_ini = 0.000004835 V, v_off_fin = -0.000003003 V 16:59:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314905 Vs 16:59:19 Temperature Measurement, Probe Number = 0, T = 20.294000 C 16:59:20 Temperature Measurement, Probe Number = 1, T = 20.050000 C 16:59:20 Temperature Measurement, Probe Number = 2, T = 20.027000 C 16:59:21 Temperature Measurement, Probe Number = 3, T = 20.001000 C 16:59:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 16:59:21 Integrated Voltage Measurement... 16:59:41 Voltage Offset Correction: v_off_ini = -0.000000006 V, v_off_fin = 0.000005242 V 16:59:41 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440755 Vs 16:59:42 Integrated Voltage Measurement... 17:00:01 Voltage Offset Correction: v_off_ini = 0.000004789 V, v_off_fin = -0.000002860 V 17:00:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320672 Vs 17:30:04 Temperature Measurement, Probe Number = 0, T = 20.275000 C 17:30:04 Temperature Measurement, Probe Number = 1, T = 20.047000 C 17:30:05 Temperature Measurement, Probe Number = 2, T = 20.020000 C 17:30:06 Temperature Measurement, Probe Number = 3, T = 19.995000 C 17:30:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:30:06 Integrated Voltage Measurement... 17:30:25 Voltage Offset Correction: v_off_ini = 0.000004001 V, v_off_fin = 0.000005811 V 17:30:25 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175527788 Vs 17:30:25 Integrated Voltage Measurement... 17:30:45 Voltage Offset Correction: v_off_ini = 0.000004875 V, v_off_fin = -0.000002194 V 17:30:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316994 Vs 17:30:48 Temperature Measurement, Probe Number = 0, T = 20.268000 C 17:30:48 Temperature Measurement, Probe Number = 1, T = 20.053000 C 17:30:49 Temperature Measurement, Probe Number = 2, T = 20.024000 C 17:30:50 Temperature Measurement, Probe Number = 3, T = 20.002000 C 17:30:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:30:50 Integrated Voltage Measurement... 17:31:10 Voltage Offset Correction: v_off_ini = 0.000001108 V, v_off_fin = 0.000004734 V 17:31:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435597 Vs 17:31:10 Integrated Voltage Measurement... 17:31:29 Voltage Offset Correction: v_off_ini = 0.000004247 V, v_off_fin = -0.000002693 V 17:31:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314679 Vs 17:31:32 Temperature Measurement, Probe Number = 0, T = 20.241000 C 17:31:33 Temperature Measurement, Probe Number = 1, T = 20.052000 C 17:31:33 Temperature Measurement, Probe Number = 2, T = 20.022000 C 17:31:34 Temperature Measurement, Probe Number = 3, T = 20.000000 C 17:31:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:31:34 Integrated Voltage Measurement... 17:31:53 Voltage Offset Correction: v_off_ini = 0.000001217 V, v_off_fin = 0.000005504 V 17:31:53 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437955 Vs 17:31:54 Integrated Voltage Measurement... 17:32:13 Voltage Offset Correction: v_off_ini = 0.000004825 V, v_off_fin = -0.000002663 V 17:32:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325955 Vs 17:32:16 Temperature Measurement, Probe Number = 0, T = 20.265000 C 17:32:17 Temperature Measurement, Probe Number = 1, T = 20.052000 C 17:32:17 Temperature Measurement, Probe Number = 2, T = 20.022000 C 17:32:18 Temperature Measurement, Probe Number = 3, T = 20.000000 C 17:32:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:32:18 Integrated Voltage Measurement... 17:32:38 Voltage Offset Correction: v_off_ini = 0.000001128 V, v_off_fin = 0.000004989 V 17:32:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175436100 Vs 17:32:38 Integrated Voltage Measurement... 17:32:57 Voltage Offset Correction: v_off_ini = 0.000004206 V, v_off_fin = -0.000002693 V 17:32:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175319402 Vs 17:33:00 Temperature Measurement, Probe Number = 0, T = 20.297000 C 17:33:01 Temperature Measurement, Probe Number = 1, T = 20.052000 C 17:33:02 Temperature Measurement, Probe Number = 2, T = 20.025000 C 17:33:02 Temperature Measurement, Probe Number = 3, T = 19.996000 C 17:33:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:33:02 Integrated Voltage Measurement... 17:33:21 Voltage Offset Correction: v_off_ini = 0.000000992 V, v_off_fin = 0.000005630 V 17:33:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437764 Vs 17:33:22 Integrated Voltage Measurement... 17:33:41 Voltage Offset Correction: v_off_ini = 0.000004730 V, v_off_fin = -0.000002250 V 17:33:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322945 Vs 17:33:44 Temperature Measurement, Probe Number = 0, T = 20.293000 C 17:33:45 Temperature Measurement, Probe Number = 1, T = 20.053000 C 17:33:45 Temperature Measurement, Probe Number = 2, T = 20.028000 C 17:33:46 Temperature Measurement, Probe Number = 3, T = 19.998000 C 17:33:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 17:33:46 Integrated Voltage Measurement... 17:34:05 Voltage Offset Correction: v_off_ini = 0.000001119 V, v_off_fin = 0.000005350 V 17:34:05 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433046 Vs 17:34:06 Integrated Voltage Measurement... 17:34:24 Voltage Offset Correction: v_off_ini = 0.000004509 V, v_off_fin = -0.000002740 V 17:34:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175327228 Vs 17:34:27 Temperature Measurement, Probe Number = 0, T = 20.304000 C 17:34:28 Temperature Measurement, Probe Number = 1, T = 20.053000 C 17:34:29 Temperature Measurement, Probe Number = 2, T = 20.026000 C 17:34:29 Temperature Measurement, Probe Number = 3, T = 20.002000 C 17:34:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 17:34:29 Integrated Voltage Measurement... 17:34:49 Voltage Offset Correction: v_off_ini = 0.000001385 V, v_off_fin = 0.000005339 V 17:34:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446244 Vs 17:34:49 Integrated Voltage Measurement... 17:35:08 Voltage Offset Correction: v_off_ini = 0.000004598 V, v_off_fin = -0.000002448 V 17:35:08 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320726 Vs 17:35:11 Temperature Measurement, Probe Number = 0, T = 20.284000 C 17:35:12 Temperature Measurement, Probe Number = 1, T = 20.054000 C 17:35:12 Temperature Measurement, Probe Number = 2, T = 20.025000 C 17:35:13 Temperature Measurement, Probe Number = 3, T = 20.001000 C 17:35:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:35:13 Integrated Voltage Measurement... 17:35:33 Voltage Offset Correction: v_off_ini = 0.000001363 V, v_off_fin = 0.000005508 V 17:35:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434010 Vs 17:35:33 Integrated Voltage Measurement... 17:35:52 Voltage Offset Correction: v_off_ini = 0.000004644 V, v_off_fin = -0.000002804 V 17:35:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321534 Vs 17:35:55 Temperature Measurement, Probe Number = 0, T = 20.291000 C 17:35:56 Temperature Measurement, Probe Number = 1, T = 20.050000 C 17:35:56 Temperature Measurement, Probe Number = 2, T = 20.025000 C 17:35:57 Temperature Measurement, Probe Number = 3, T = 19.999000 C 17:35:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 17:35:57 Integrated Voltage Measurement... 17:36:17 Voltage Offset Correction: v_off_ini = 0.000001261 V, v_off_fin = 0.000005513 V 17:36:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437691 Vs 17:36:17 Integrated Voltage Measurement... 17:36:36 Voltage Offset Correction: v_off_ini = 0.000004835 V, v_off_fin = -0.000002208 V 17:36:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325608 Vs 17:36:39 Temperature Measurement, Probe Number = 0, T = 20.265000 C 17:36:40 Temperature Measurement, Probe Number = 1, T = 20.050000 C 17:36:40 Temperature Measurement, Probe Number = 2, T = 20.026000 C 17:36:41 Temperature Measurement, Probe Number = 3, T = 19.999000 C 17:36:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.03 P3 = Top 1, Value = 20.00 17:36:41 Integrated Voltage Measurement... 17:37:00 Voltage Offset Correction: v_off_ini = 0.000001278 V, v_off_fin = 0.000005071 V 17:37:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175435926 Vs 17:37:01 Integrated Voltage Measurement... 17:37:20 Voltage Offset Correction: v_off_ini = 0.000004993 V, v_off_fin = -0.000003098 V 17:37:20 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175320794 Vs 18:07:22 Temperature Measurement, Probe Number = 0, T = 20.185000 C 18:07:23 Temperature Measurement, Probe Number = 1, T = 20.041000 C 18:07:24 Temperature Measurement, Probe Number = 2, T = 20.008000 C 18:07:25 Temperature Measurement, Probe Number = 3, T = 19.990000 C 18:07:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:07:25 Integrated Voltage Measurement... 18:07:44 Voltage Offset Correction: v_off_ini = 0.000003763 V, v_off_fin = 0.000005608 V 18:07:44 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175533198 Vs 18:07:45 Integrated Voltage Measurement... 18:08:04 Voltage Offset Correction: v_off_ini = 0.000004615 V, v_off_fin = -0.000001181 V 18:08:05 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175316029 Vs 18:08:07 Temperature Measurement, Probe Number = 0, T = 20.235000 C 18:08:08 Temperature Measurement, Probe Number = 1, T = 20.040000 C 18:08:09 Temperature Measurement, Probe Number = 2, T = 20.008000 C 18:08:09 Temperature Measurement, Probe Number = 3, T = 19.988000 C 18:08:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:08:09 Integrated Voltage Measurement... 18:08:29 Voltage Offset Correction: v_off_ini = 0.000002043 V, v_off_fin = 0.000005479 V 18:08:29 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175427525 Vs 18:08:29 Integrated Voltage Measurement... 18:08:48 Voltage Offset Correction: v_off_ini = 0.000005532 V, v_off_fin = -0.000001941 V 18:08:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312397 Vs 18:08:51 Temperature Measurement, Probe Number = 0, T = 20.201000 C 18:08:52 Temperature Measurement, Probe Number = 1, T = 20.043000 C 18:08:53 Temperature Measurement, Probe Number = 2, T = 20.012000 C 18:08:53 Temperature Measurement, Probe Number = 3, T = 19.992000 C 18:08:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:08:53 Integrated Voltage Measurement... 18:09:13 Voltage Offset Correction: v_off_ini = 0.000001600 V, v_off_fin = 0.000005617 V 18:09:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439232 Vs 18:09:14 Integrated Voltage Measurement... 18:09:33 Voltage Offset Correction: v_off_ini = 0.000004803 V, v_off_fin = -0.000002220 V 18:09:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311552 Vs 18:09:36 Temperature Measurement, Probe Number = 0, T = 20.244000 C 18:09:36 Temperature Measurement, Probe Number = 1, T = 20.046000 C 18:09:37 Temperature Measurement, Probe Number = 2, T = 20.015000 C 18:09:38 Temperature Measurement, Probe Number = 3, T = 19.994000 C 18:09:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.05 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 18:09:38 Integrated Voltage Measurement... 18:09:57 Voltage Offset Correction: v_off_ini = 0.000001775 V, v_off_fin = 0.000005870 V 18:09:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441157 Vs 18:09:57 Integrated Voltage Measurement... 18:10:16 Voltage Offset Correction: v_off_ini = 0.000005397 V, v_off_fin = -0.000001588 V 18:10:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312431 Vs 18:10:19 Temperature Measurement, Probe Number = 0, T = 20.243000 C 18:10:20 Temperature Measurement, Probe Number = 1, T = 20.044000 C 18:10:21 Temperature Measurement, Probe Number = 2, T = 20.012000 C 18:10:21 Temperature Measurement, Probe Number = 3, T = 19.991000 C 18:10:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:10:21 Integrated Voltage Measurement... 18:10:41 Voltage Offset Correction: v_off_ini = 0.000001345 V, v_off_fin = 0.000006366 V 18:10:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175447406 Vs 18:10:42 Integrated Voltage Measurement... 18:11:01 Voltage Offset Correction: v_off_ini = 0.000005658 V, v_off_fin = -0.000000894 V 18:11:01 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175304465 Vs 18:11:04 Temperature Measurement, Probe Number = 0, T = 20.216000 C 18:11:05 Temperature Measurement, Probe Number = 1, T = 20.042000 C 18:11:05 Temperature Measurement, Probe Number = 2, T = 20.018000 C 18:11:06 Temperature Measurement, Probe Number = 3, T = 19.993000 C 18:11:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 19.99 18:11:06 Integrated Voltage Measurement... 18:11:26 Voltage Offset Correction: v_off_ini = 0.000002090 V, v_off_fin = 0.000006099 V 18:11:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175440771 Vs 18:11:26 Integrated Voltage Measurement... 18:11:45 Voltage Offset Correction: v_off_ini = 0.000006044 V, v_off_fin = -0.000002362 V 18:11:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314800 Vs 18:11:48 Temperature Measurement, Probe Number = 0, T = 20.208000 C 18:11:49 Temperature Measurement, Probe Number = 1, T = 20.041000 C 18:11:50 Temperature Measurement, Probe Number = 2, T = 20.015000 C 18:11:50 Temperature Measurement, Probe Number = 3, T = 19.995000 C 18:11:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 18:11:50 Integrated Voltage Measurement... 18:12:10 Voltage Offset Correction: v_off_ini = 0.000001945 V, v_off_fin = 0.000005779 V 18:12:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441927 Vs 18:12:10 Integrated Voltage Measurement... 18:12:30 Voltage Offset Correction: v_off_ini = 0.000004918 V, v_off_fin = -0.000002702 V 18:12:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175328984 Vs 18:12:32 Temperature Measurement, Probe Number = 0, T = 20.184000 C 18:12:33 Temperature Measurement, Probe Number = 1, T = 20.040000 C 18:12:34 Temperature Measurement, Probe Number = 2, T = 20.015000 C 18:12:34 Temperature Measurement, Probe Number = 3, T = 19.996000 C 18:12:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.02 P3 = Top 1, Value = 20.00 18:12:35 Integrated Voltage Measurement... 18:12:54 Voltage Offset Correction: v_off_ini = 0.000001369 V, v_off_fin = 0.000005988 V 18:12:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175443085 Vs 18:12:54 Integrated Voltage Measurement... 18:13:13 Voltage Offset Correction: v_off_ini = 0.000005388 V, v_off_fin = -0.000002106 V 18:13:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316396 Vs 18:13:16 Temperature Measurement, Probe Number = 0, T = 20.243000 C 18:13:17 Temperature Measurement, Probe Number = 1, T = 20.043000 C 18:13:17 Temperature Measurement, Probe Number = 2, T = 20.013000 C 18:13:18 Temperature Measurement, Probe Number = 3, T = 19.994000 C 18:13:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:13:18 Integrated Voltage Measurement... 18:13:37 Voltage Offset Correction: v_off_ini = 0.000000727 V, v_off_fin = 0.000005663 V 18:13:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440152 Vs 18:13:37 Integrated Voltage Measurement... 18:13:57 Voltage Offset Correction: v_off_ini = 0.000004886 V, v_off_fin = -0.000001872 V 18:13:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320050 Vs 18:14:00 Temperature Measurement, Probe Number = 0, T = 20.220000 C 18:14:00 Temperature Measurement, Probe Number = 1, T = 20.042000 C 18:14:01 Temperature Measurement, Probe Number = 2, T = 20.014000 C 18:14:02 Temperature Measurement, Probe Number = 3, T = 19.993000 C 18:14:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:14:02 Integrated Voltage Measurement... 18:14:22 Voltage Offset Correction: v_off_ini = 0.000001469 V, v_off_fin = 0.000005410 V 18:14:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175438218 Vs 18:14:22 Integrated Voltage Measurement... 18:14:41 Voltage Offset Correction: v_off_ini = 0.000004405 V, v_off_fin = -0.000002603 V 18:14:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321475 Vs 18:44:44 Temperature Measurement, Probe Number = 0, T = 20.200000 C 18:44:45 Temperature Measurement, Probe Number = 1, T = 20.034000 C 18:44:45 Temperature Measurement, Probe Number = 2, T = 20.005000 C 18:44:46 Temperature Measurement, Probe Number = 3, T = 19.985000 C 18:44:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 18:44:46 Integrated Voltage Measurement... 18:45:05 Voltage Offset Correction: v_off_ini = 0.000003370 V, v_off_fin = 0.000005964 V 18:45:05 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175527105 Vs 18:45:05 Integrated Voltage Measurement... 18:45:25 Voltage Offset Correction: v_off_ini = 0.000005243 V, v_off_fin = -0.000002047 V 18:45:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314183 Vs 18:45:27 Temperature Measurement, Probe Number = 0, T = 20.193000 C 18:45:28 Temperature Measurement, Probe Number = 1, T = 20.033000 C 18:45:29 Temperature Measurement, Probe Number = 2, T = 20.011000 C 18:45:29 Temperature Measurement, Probe Number = 3, T = 19.988000 C 18:45:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:45:29 Integrated Voltage Measurement... 18:45:49 Voltage Offset Correction: v_off_ini = 0.000001264 V, v_off_fin = 0.000005806 V 18:45:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436050 Vs 18:45:49 Integrated Voltage Measurement... 18:46:08 Voltage Offset Correction: v_off_ini = 0.000005307 V, v_off_fin = -0.000002241 V 18:46:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314469 Vs 18:46:11 Temperature Measurement, Probe Number = 0, T = 20.241000 C 18:46:12 Temperature Measurement, Probe Number = 1, T = 20.037000 C 18:46:12 Temperature Measurement, Probe Number = 2, T = 20.012000 C 18:46:13 Temperature Measurement, Probe Number = 3, T = 19.992000 C 18:46:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:46:13 Integrated Voltage Measurement... 18:46:32 Voltage Offset Correction: v_off_ini = 0.000001556 V, v_off_fin = 0.000005850 V 18:46:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440022 Vs 18:46:32 Integrated Voltage Measurement... 18:46:52 Voltage Offset Correction: v_off_ini = 0.000005281 V, v_off_fin = -0.000001706 V 18:46:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323791 Vs 18:46:55 Temperature Measurement, Probe Number = 0, T = 20.265000 C 18:46:55 Temperature Measurement, Probe Number = 1, T = 20.038000 C 18:46:56 Temperature Measurement, Probe Number = 2, T = 20.013000 C 18:46:57 Temperature Measurement, Probe Number = 3, T = 19.991000 C 18:46:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:46:57 Integrated Voltage Measurement... 18:47:16 Voltage Offset Correction: v_off_ini = 0.000001631 V, v_off_fin = 0.000006471 V 18:47:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175442009 Vs 18:47:16 Integrated Voltage Measurement... 18:47:35 Voltage Offset Correction: v_off_ini = 0.000005503 V, v_off_fin = -0.000002376 V 18:47:35 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175314252 Vs 18:47:38 Temperature Measurement, Probe Number = 0, T = 20.242000 C 18:47:39 Temperature Measurement, Probe Number = 1, T = 20.029000 C 18:47:39 Temperature Measurement, Probe Number = 2, T = 20.006000 C 18:47:40 Temperature Measurement, Probe Number = 3, T = 19.985000 C 18:47:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.98 18:47:40 Integrated Voltage Measurement... 18:47:59 Voltage Offset Correction: v_off_ini = 0.000002047 V, v_off_fin = 0.000006018 V 18:48:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175448102 Vs 18:48:00 Integrated Voltage Measurement... 18:48:19 Voltage Offset Correction: v_off_ini = 0.000005327 V, v_off_fin = -0.000002425 V 18:48:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311555 Vs 18:48:22 Temperature Measurement, Probe Number = 0, T = 20.198000 C 18:48:22 Temperature Measurement, Probe Number = 1, T = 20.033000 C 18:48:23 Temperature Measurement, Probe Number = 2, T = 20.007000 C 18:48:24 Temperature Measurement, Probe Number = 3, T = 19.988000 C 18:48:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:48:24 Integrated Voltage Measurement... 18:48:43 Voltage Offset Correction: v_off_ini = 0.000001623 V, v_off_fin = 0.000006674 V 18:48:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175448289 Vs 18:48:43 Integrated Voltage Measurement... 18:49:02 Voltage Offset Correction: v_off_ini = 0.000006002 V, v_off_fin = -0.000001872 V 18:49:02 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175313926 Vs 18:49:05 Temperature Measurement, Probe Number = 0, T = 20.142000 C 18:49:06 Temperature Measurement, Probe Number = 1, T = 20.034000 C 18:49:06 Temperature Measurement, Probe Number = 2, T = 20.008000 C 18:49:07 Temperature Measurement, Probe Number = 3, T = 19.990000 C 18:49:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:49:07 Integrated Voltage Measurement... 18:49:26 Voltage Offset Correction: v_off_ini = 0.000001696 V, v_off_fin = 0.000006222 V 18:49:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446294 Vs 18:49:27 Integrated Voltage Measurement... 18:49:46 Voltage Offset Correction: v_off_ini = 0.000005472 V, v_off_fin = -0.000001576 V 18:49:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321370 Vs 18:49:49 Temperature Measurement, Probe Number = 0, T = 20.184000 C 18:49:50 Temperature Measurement, Probe Number = 1, T = 20.037000 C 18:49:50 Temperature Measurement, Probe Number = 2, T = 20.011000 C 18:49:51 Temperature Measurement, Probe Number = 3, T = 19.991000 C 18:49:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:49:51 Integrated Voltage Measurement... 18:50:10 Voltage Offset Correction: v_off_ini = 0.000001184 V, v_off_fin = 0.000005520 V 18:50:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434685 Vs 18:50:11 Integrated Voltage Measurement... 18:50:30 Voltage Offset Correction: v_off_ini = 0.000004734 V, v_off_fin = -0.000002554 V 18:50:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175327994 Vs 18:50:33 Temperature Measurement, Probe Number = 0, T = 20.194000 C 18:50:34 Temperature Measurement, Probe Number = 1, T = 20.035000 C 18:50:34 Temperature Measurement, Probe Number = 2, T = 20.009000 C 18:50:35 Temperature Measurement, Probe Number = 3, T = 19.990000 C 18:50:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:50:35 Integrated Voltage Measurement... 18:50:54 Voltage Offset Correction: v_off_ini = 0.000000785 V, v_off_fin = 0.000005293 V 18:50:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430945 Vs 18:50:55 Integrated Voltage Measurement... 18:51:14 Voltage Offset Correction: v_off_ini = 0.000004306 V, v_off_fin = -0.000002754 V 18:51:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175326089 Vs 18:51:17 Temperature Measurement, Probe Number = 0, T = 20.203000 C 18:51:18 Temperature Measurement, Probe Number = 1, T = 20.035000 C 18:51:18 Temperature Measurement, Probe Number = 2, T = 20.008000 C 18:51:19 Temperature Measurement, Probe Number = 3, T = 19.990000 C 18:51:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.04 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 18:51:19 Integrated Voltage Measurement... 18:51:38 Voltage Offset Correction: v_off_ini = 0.000000854 V, v_off_fin = 0.000005738 V 18:51:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431013 Vs 18:51:39 Integrated Voltage Measurement... 18:51:58 Voltage Offset Correction: v_off_ini = 0.000004909 V, v_off_fin = -0.000002055 V 18:51:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310450 Vs 19:22:00 Temperature Measurement, Probe Number = 0, T = 20.201000 C 19:22:01 Temperature Measurement, Probe Number = 1, T = 20.032000 C 19:22:02 Temperature Measurement, Probe Number = 2, T = 20.004000 C 19:22:02 Temperature Measurement, Probe Number = 3, T = 19.987000 C 19:22:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 19:22:03 Integrated Voltage Measurement... 19:22:22 Voltage Offset Correction: v_off_ini = 0.000003719 V, v_off_fin = 0.000005725 V 19:22:22 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175529218 Vs 19:22:22 Integrated Voltage Measurement... 19:22:41 Voltage Offset Correction: v_off_ini = 0.000005271 V, v_off_fin = -0.000002193 V 19:22:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316326 Vs 19:22:44 Temperature Measurement, Probe Number = 0, T = 20.251000 C 19:22:45 Temperature Measurement, Probe Number = 1, T = 20.031000 C 19:22:45 Temperature Measurement, Probe Number = 2, T = 20.003000 C 19:22:46 Temperature Measurement, Probe Number = 3, T = 19.983000 C 19:22:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:22:46 Integrated Voltage Measurement... 19:23:05 Voltage Offset Correction: v_off_ini = 0.000000691 V, v_off_fin = 0.000005570 V 19:23:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433911 Vs 19:23:06 Integrated Voltage Measurement... 19:23:25 Voltage Offset Correction: v_off_ini = 0.000004797 V, v_off_fin = -0.000002124 V 19:23:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316390 Vs 19:23:28 Temperature Measurement, Probe Number = 0, T = 20.222000 C 19:23:29 Temperature Measurement, Probe Number = 1, T = 20.030000 C 19:23:29 Temperature Measurement, Probe Number = 2, T = 20.001000 C 19:23:30 Temperature Measurement, Probe Number = 3, T = 19.982000 C 19:23:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:23:30 Integrated Voltage Measurement... 19:23:49 Voltage Offset Correction: v_off_ini = 0.000001029 V, v_off_fin = 0.000005448 V 19:23:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175436530 Vs 19:23:50 Integrated Voltage Measurement... 19:24:09 Voltage Offset Correction: v_off_ini = 0.000004953 V, v_off_fin = -0.000002707 V 19:24:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312037 Vs 19:24:11 Temperature Measurement, Probe Number = 0, T = 20.149000 C 19:24:12 Temperature Measurement, Probe Number = 1, T = 20.030000 C 19:24:13 Temperature Measurement, Probe Number = 2, T = 20.000000 C 19:24:13 Temperature Measurement, Probe Number = 3, T = 19.981000 C 19:24:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:24:14 Integrated Voltage Measurement... 19:24:33 Voltage Offset Correction: v_off_ini = 0.000001570 V, v_off_fin = 0.000005938 V 19:24:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175438868 Vs 19:24:33 Integrated Voltage Measurement... 19:24:52 Voltage Offset Correction: v_off_ini = 0.000004998 V, v_off_fin = -0.000002209 V 19:24:52 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315424 Vs 19:24:55 Temperature Measurement, Probe Number = 0, T = 20.117000 C 19:24:56 Temperature Measurement, Probe Number = 1, T = 20.030000 C 19:24:56 Temperature Measurement, Probe Number = 2, T = 20.000000 C 19:24:57 Temperature Measurement, Probe Number = 3, T = 19.984000 C 19:24:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:24:57 Integrated Voltage Measurement... 19:25:17 Voltage Offset Correction: v_off_ini = 0.000001495 V, v_off_fin = 0.000006378 V 19:25:17 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440184 Vs 19:25:17 Integrated Voltage Measurement... 19:25:36 Voltage Offset Correction: v_off_ini = 0.000005230 V, v_off_fin = -0.000002005 V 19:25:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306967 Vs 19:25:39 Temperature Measurement, Probe Number = 0, T = 20.079000 C 19:25:40 Temperature Measurement, Probe Number = 1, T = 20.028000 C 19:25:40 Temperature Measurement, Probe Number = 2, T = 20.003000 C 19:25:41 Temperature Measurement, Probe Number = 3, T = 19.985000 C 19:25:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.08 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:25:41 Integrated Voltage Measurement... 19:26:00 Voltage Offset Correction: v_off_ini = 0.000001565 V, v_off_fin = 0.000006046 V 19:26:00 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175442664 Vs 19:26:01 Integrated Voltage Measurement... 19:26:20 Voltage Offset Correction: v_off_ini = 0.000005186 V, v_off_fin = -0.000002375 V 19:26:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309426 Vs 19:26:23 Temperature Measurement, Probe Number = 0, T = 20.124000 C 19:26:23 Temperature Measurement, Probe Number = 1, T = 20.031000 C 19:26:24 Temperature Measurement, Probe Number = 2, T = 20.002000 C 19:26:25 Temperature Measurement, Probe Number = 3, T = 19.985000 C 19:26:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.12 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:26:25 Integrated Voltage Measurement... 19:26:44 Voltage Offset Correction: v_off_ini = 0.000001777 V, v_off_fin = 0.000005425 V 19:26:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175437804 Vs 19:26:44 Integrated Voltage Measurement... 19:27:04 Voltage Offset Correction: v_off_ini = 0.000005119 V, v_off_fin = -0.000001967 V 19:27:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321446 Vs 19:27:06 Temperature Measurement, Probe Number = 0, T = 20.164000 C 19:27:07 Temperature Measurement, Probe Number = 1, T = 20.032000 C 19:27:08 Temperature Measurement, Probe Number = 2, T = 20.004000 C 19:27:08 Temperature Measurement, Probe Number = 3, T = 19.988000 C 19:27:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.99 19:27:09 Integrated Voltage Measurement... 19:27:28 Voltage Offset Correction: v_off_ini = 0.000001621 V, v_off_fin = 0.000005755 V 19:27:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433848 Vs 19:27:28 Integrated Voltage Measurement... 19:27:48 Voltage Offset Correction: v_off_ini = 0.000004763 V, v_off_fin = -0.000002309 V 19:27:48 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175320551 Vs 19:27:51 Temperature Measurement, Probe Number = 0, T = 20.222000 C 19:27:51 Temperature Measurement, Probe Number = 1, T = 20.031000 C 19:27:52 Temperature Measurement, Probe Number = 2, T = 20.003000 C 19:27:53 Temperature Measurement, Probe Number = 3, T = 19.984000 C 19:27:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.00 P3 = Top 1, Value = 19.98 19:27:53 Integrated Voltage Measurement... 19:28:12 Voltage Offset Correction: v_off_ini = 0.000001744 V, v_off_fin = 0.000005614 V 19:28:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431630 Vs 19:28:12 Integrated Voltage Measurement... 19:28:31 Voltage Offset Correction: v_off_ini = 0.000005126 V, v_off_fin = -0.000001747 V 19:28:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312455 Vs 19:28:34 Temperature Measurement, Probe Number = 0, T = 20.210000 C 19:28:35 Temperature Measurement, Probe Number = 1, T = 20.032000 C 19:28:35 Temperature Measurement, Probe Number = 2, T = 20.006000 C 19:28:36 Temperature Measurement, Probe Number = 3, T = 19.986000 C 19:28:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.03 P2 = Bottom 3, Value = 20.01 P3 = Top 1, Value = 19.99 19:28:36 Integrated Voltage Measurement... 19:28:56 Voltage Offset Correction: v_off_ini = 0.000001546 V, v_off_fin = 0.000006214 V 19:28:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445326 Vs 19:28:56 Integrated Voltage Measurement... 19:29:15 Voltage Offset Correction: v_off_ini = 0.000005231 V, v_off_fin = -0.000001806 V 19:29:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310373 Vs 19:59:18 Temperature Measurement, Probe Number = 0, T = 20.088000 C 19:59:19 Temperature Measurement, Probe Number = 1, T = 20.019000 C 19:59:20 Temperature Measurement, Probe Number = 2, T = 19.989000 C 19:59:20 Temperature Measurement, Probe Number = 3, T = 19.975000 C 19:59:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.09 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 19:59:21 Integrated Voltage Measurement... 19:59:40 Voltage Offset Correction: v_off_ini = 0.000003533 V, v_off_fin = 0.000005830 V 19:59:40 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175525139 Vs 19:59:40 Integrated Voltage Measurement... 19:59:59 Voltage Offset Correction: v_off_ini = 0.000005117 V, v_off_fin = -0.000002705 V 20:00:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175321321 Vs 20:00:02 Temperature Measurement, Probe Number = 0, T = 20.155000 C 20:00:03 Temperature Measurement, Probe Number = 1, T = 20.021000 C 20:00:04 Temperature Measurement, Probe Number = 2, T = 19.992000 C 20:00:04 Temperature Measurement, Probe Number = 3, T = 19.976000 C 20:00:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:00:05 Integrated Voltage Measurement... 20:00:24 Voltage Offset Correction: v_off_ini = 0.000000894 V, v_off_fin = 0.000005834 V 20:00:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437729 Vs 20:00:24 Integrated Voltage Measurement... 20:00:44 Voltage Offset Correction: v_off_ini = 0.000005137 V, v_off_fin = -0.000002702 V 20:00:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322755 Vs 20:00:46 Temperature Measurement, Probe Number = 0, T = 20.177000 C 20:00:47 Temperature Measurement, Probe Number = 1, T = 20.021000 C 20:00:48 Temperature Measurement, Probe Number = 2, T = 19.994000 C 20:00:48 Temperature Measurement, Probe Number = 3, T = 19.979000 C 20:00:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:00:49 Integrated Voltage Measurement... 20:01:08 Voltage Offset Correction: v_off_ini = 0.000001362 V, v_off_fin = 0.000005678 V 20:01:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175441747 Vs 20:01:08 Integrated Voltage Measurement... 20:01:28 Voltage Offset Correction: v_off_ini = 0.000005037 V, v_off_fin = -0.000001539 V 20:01:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322046 Vs 20:01:30 Temperature Measurement, Probe Number = 0, T = 20.178000 C 20:01:31 Temperature Measurement, Probe Number = 1, T = 20.024000 C 20:01:32 Temperature Measurement, Probe Number = 2, T = 19.994000 C 20:01:32 Temperature Measurement, Probe Number = 3, T = 19.983000 C 20:01:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:01:33 Integrated Voltage Measurement... 20:01:52 Voltage Offset Correction: v_off_ini = 0.000001186 V, v_off_fin = 0.000005648 V 20:01:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437750 Vs 20:01:52 Integrated Voltage Measurement... 20:02:11 Voltage Offset Correction: v_off_ini = 0.000004854 V, v_off_fin = -0.000001927 V 20:02:11 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175316925 Vs 20:02:14 Temperature Measurement, Probe Number = 0, T = 20.182000 C 20:02:15 Temperature Measurement, Probe Number = 1, T = 20.024000 C 20:02:15 Temperature Measurement, Probe Number = 2, T = 19.994000 C 20:02:16 Temperature Measurement, Probe Number = 3, T = 19.982000 C 20:02:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:02:16 Integrated Voltage Measurement... 20:02:35 Voltage Offset Correction: v_off_ini = 0.000002471 V, v_off_fin = 0.000006318 V 20:02:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446404 Vs 20:02:35 Integrated Voltage Measurement... 20:02:55 Voltage Offset Correction: v_off_ini = 0.000005543 V, v_off_fin = -0.000001613 V 20:02:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317266 Vs 20:02:58 Temperature Measurement, Probe Number = 0, T = 20.176000 C 20:02:58 Temperature Measurement, Probe Number = 1, T = 20.022000 C 20:02:59 Temperature Measurement, Probe Number = 2, T = 19.992000 C 20:02:59 Temperature Measurement, Probe Number = 3, T = 19.978000 C 20:03:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:03:00 Integrated Voltage Measurement... 20:03:19 Voltage Offset Correction: v_off_ini = 0.000001461 V, v_off_fin = 0.000005761 V 20:03:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440122 Vs 20:03:19 Integrated Voltage Measurement... 20:03:38 Voltage Offset Correction: v_off_ini = 0.000005560 V, v_off_fin = -0.000001469 V 20:03:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309173 Vs 20:03:41 Temperature Measurement, Probe Number = 0, T = 20.183000 C 20:03:42 Temperature Measurement, Probe Number = 1, T = 20.022000 C 20:03:42 Temperature Measurement, Probe Number = 2, T = 19.994000 C 20:03:43 Temperature Measurement, Probe Number = 3, T = 19.979000 C 20:03:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:03:43 Integrated Voltage Measurement... 20:04:02 Voltage Offset Correction: v_off_ini = 0.000002188 V, v_off_fin = 0.000005801 V 20:04:02 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445930 Vs 20:04:03 Integrated Voltage Measurement... 20:04:22 Voltage Offset Correction: v_off_ini = 0.000005378 V, v_off_fin = -0.000002159 V 20:04:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322261 Vs 20:04:25 Temperature Measurement, Probe Number = 0, T = 20.203000 C 20:04:25 Temperature Measurement, Probe Number = 1, T = 20.022000 C 20:04:26 Temperature Measurement, Probe Number = 2, T = 19.993000 C 20:04:27 Temperature Measurement, Probe Number = 3, T = 19.977000 C 20:04:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:04:27 Integrated Voltage Measurement... 20:04:46 Voltage Offset Correction: v_off_ini = 0.000001173 V, v_off_fin = 0.000005612 V 20:04:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434638 Vs 20:04:47 Integrated Voltage Measurement... 20:05:06 Voltage Offset Correction: v_off_ini = 0.000004530 V, v_off_fin = -0.000002445 V 20:05:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175324026 Vs 20:05:09 Temperature Measurement, Probe Number = 0, T = 20.169000 C 20:05:10 Temperature Measurement, Probe Number = 1, T = 20.021000 C 20:05:10 Temperature Measurement, Probe Number = 2, T = 19.993000 C 20:05:11 Temperature Measurement, Probe Number = 3, T = 19.980000 C 20:05:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:05:11 Integrated Voltage Measurement... 20:05:30 Voltage Offset Correction: v_off_ini = 0.000000985 V, v_off_fin = 0.000005905 V 20:05:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175439450 Vs 20:05:30 Integrated Voltage Measurement... 20:05:49 Voltage Offset Correction: v_off_ini = 0.000005029 V, v_off_fin = -0.000002716 V 20:05:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317260 Vs 20:05:52 Temperature Measurement, Probe Number = 0, T = 20.175000 C 20:05:53 Temperature Measurement, Probe Number = 1, T = 20.020000 C 20:05:54 Temperature Measurement, Probe Number = 2, T = 19.990000 C 20:05:54 Temperature Measurement, Probe Number = 3, T = 19.977000 C 20:05:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 20:05:54 Integrated Voltage Measurement... 20:06:13 Voltage Offset Correction: v_off_ini = 0.000001332 V, v_off_fin = 0.000005556 V 20:06:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175445061 Vs 20:06:14 Integrated Voltage Measurement... 20:06:33 Voltage Offset Correction: v_off_ini = 0.000004968 V, v_off_fin = -0.000002130 V 20:06:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175320290 Vs 20:36:36 Temperature Measurement, Probe Number = 0, T = 20.070000 C 20:36:37 Temperature Measurement, Probe Number = 1, T = 20.010000 C 20:36:37 Temperature Measurement, Probe Number = 2, T = 19.980000 C 20:36:38 Temperature Measurement, Probe Number = 3, T = 19.967000 C 20:36:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.07 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:36:38 Integrated Voltage Measurement... 20:36:57 Voltage Offset Correction: v_off_ini = 0.000003380 V, v_off_fin = 0.000005401 V 20:36:57 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175522469 Vs 20:36:58 Integrated Voltage Measurement... 20:37:17 Voltage Offset Correction: v_off_ini = 0.000004708 V, v_off_fin = -0.000002225 V 20:37:17 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175318542 Vs 20:37:20 Temperature Measurement, Probe Number = 0, T = 20.062000 C 20:37:20 Temperature Measurement, Probe Number = 1, T = 20.011000 C 20:37:21 Temperature Measurement, Probe Number = 2, T = 19.976000 C 20:37:22 Temperature Measurement, Probe Number = 3, T = 19.967000 C 20:37:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:37:22 Integrated Voltage Measurement... 20:37:42 Voltage Offset Correction: v_off_ini = 0.000001410 V, v_off_fin = 0.000005434 V 20:37:42 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175442606 Vs 20:37:42 Integrated Voltage Measurement... 20:38:01 Voltage Offset Correction: v_off_ini = 0.000004741 V, v_off_fin = -0.000001956 V 20:38:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314709 Vs 20:38:04 Temperature Measurement, Probe Number = 0, T = 20.058000 C 20:38:05 Temperature Measurement, Probe Number = 1, T = 20.014000 C 20:38:05 Temperature Measurement, Probe Number = 2, T = 19.982000 C 20:38:06 Temperature Measurement, Probe Number = 3, T = 19.971000 C 20:38:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.06 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:38:06 Integrated Voltage Measurement... 20:38:25 Voltage Offset Correction: v_off_ini = 0.000001102 V, v_off_fin = 0.000006121 V 20:38:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175443619 Vs 20:38:26 Integrated Voltage Measurement... 20:38:45 Voltage Offset Correction: v_off_ini = 0.000005298 V, v_off_fin = -0.000001508 V 20:38:45 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319479 Vs 20:38:48 Temperature Measurement, Probe Number = 0, T = 20.142000 C 20:38:49 Temperature Measurement, Probe Number = 1, T = 20.011000 C 20:38:50 Temperature Measurement, Probe Number = 2, T = 19.981000 C 20:38:50 Temperature Measurement, Probe Number = 3, T = 19.971000 C 20:38:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:38:50 Integrated Voltage Measurement... 20:39:09 Voltage Offset Correction: v_off_ini = 0.000001956 V, v_off_fin = 0.000006100 V 20:39:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441209 Vs 20:39:10 Integrated Voltage Measurement... 20:39:29 Voltage Offset Correction: v_off_ini = 0.000005492 V, v_off_fin = -0.000002008 V 20:39:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318110 Vs 20:39:32 Temperature Measurement, Probe Number = 0, T = 20.172000 C 20:39:33 Temperature Measurement, Probe Number = 1, T = 20.011000 C 20:39:33 Temperature Measurement, Probe Number = 2, T = 19.978000 C 20:39:34 Temperature Measurement, Probe Number = 3, T = 19.970000 C 20:39:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:39:34 Integrated Voltage Measurement... 20:39:53 Voltage Offset Correction: v_off_ini = 0.000001611 V, v_off_fin = 0.000005820 V 20:39:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175445906 Vs 20:39:54 Integrated Voltage Measurement... 20:40:13 Voltage Offset Correction: v_off_ini = 0.000005138 V, v_off_fin = -0.000002739 V 20:40:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175314865 Vs 20:40:15 Temperature Measurement, Probe Number = 0, T = 20.163000 C 20:40:16 Temperature Measurement, Probe Number = 1, T = 20.012000 C 20:40:17 Temperature Measurement, Probe Number = 2, T = 19.982000 C 20:40:17 Temperature Measurement, Probe Number = 3, T = 19.974000 C 20:40:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:40:18 Integrated Voltage Measurement... 20:40:37 Voltage Offset Correction: v_off_ini = 0.000001259 V, v_off_fin = 0.000005782 V 20:40:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175446469 Vs 20:40:37 Integrated Voltage Measurement... 20:40:57 Voltage Offset Correction: v_off_ini = 0.000005169 V, v_off_fin = -0.000001715 V 20:40:57 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175323803 Vs 20:40:59 Temperature Measurement, Probe Number = 0, T = 20.140000 C 20:41:00 Temperature Measurement, Probe Number = 1, T = 20.010000 C 20:41:01 Temperature Measurement, Probe Number = 2, T = 19.981000 C 20:41:01 Temperature Measurement, Probe Number = 3, T = 19.973000 C 20:41:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:41:02 Integrated Voltage Measurement... 20:41:21 Voltage Offset Correction: v_off_ini = 0.000001889 V, v_off_fin = 0.000005790 V 20:41:21 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175437719 Vs 20:41:21 Integrated Voltage Measurement... 20:41:40 Voltage Offset Correction: v_off_ini = 0.000004968 V, v_off_fin = -0.000002001 V 20:41:40 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175318122 Vs 20:41:43 Temperature Measurement, Probe Number = 0, T = 20.134000 C 20:41:44 Temperature Measurement, Probe Number = 1, T = 20.010000 C 20:41:45 Temperature Measurement, Probe Number = 2, T = 19.980000 C 20:41:45 Temperature Measurement, Probe Number = 3, T = 19.972000 C 20:41:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:41:46 Integrated Voltage Measurement... 20:42:05 Voltage Offset Correction: v_off_ini = 0.000001631 V, v_off_fin = 0.000005943 V 20:42:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175440104 Vs 20:42:05 Integrated Voltage Measurement... 20:42:24 Voltage Offset Correction: v_off_ini = 0.000004865 V, v_off_fin = -0.000002187 V 20:42:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175326166 Vs 20:42:27 Temperature Measurement, Probe Number = 0, T = 20.145000 C 20:42:28 Temperature Measurement, Probe Number = 1, T = 20.013000 C 20:42:29 Temperature Measurement, Probe Number = 2, T = 19.983000 C 20:42:29 Temperature Measurement, Probe Number = 3, T = 19.973000 C 20:42:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 20:42:29 Integrated Voltage Measurement... 20:42:49 Voltage Offset Correction: v_off_ini = 0.000001308 V, v_off_fin = 0.000005493 V 20:42:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175441148 Vs 20:42:49 Integrated Voltage Measurement... 20:43:08 Voltage Offset Correction: v_off_ini = 0.000004958 V, v_off_fin = -0.000002731 V 20:43:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175326564 Vs 20:43:11 Temperature Measurement, Probe Number = 0, T = 20.218000 C 20:43:12 Temperature Measurement, Probe Number = 1, T = 20.012000 C 20:43:13 Temperature Measurement, Probe Number = 2, T = 19.984000 C 20:43:13 Temperature Measurement, Probe Number = 3, T = 19.975000 C 20:43:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 20:43:13 Integrated Voltage Measurement... 20:43:33 Voltage Offset Correction: v_off_ini = 0.000001249 V, v_off_fin = 0.000005595 V 20:43:33 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175439592 Vs 20:43:33 Integrated Voltage Measurement... 20:43:53 Voltage Offset Correction: v_off_ini = 0.000005163 V, v_off_fin = -0.000002025 V 20:43:53 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175325480 Vs 21:13:55 Temperature Measurement, Probe Number = 0, T = 20.240000 C 21:13:56 Temperature Measurement, Probe Number = 1, T = 20.016000 C 21:13:57 Temperature Measurement, Probe Number = 2, T = 19.985000 C 21:13:57 Temperature Measurement, Probe Number = 3, T = 19.974000 C 21:13:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 21:13:58 Integrated Voltage Measurement... 21:14:17 Voltage Offset Correction: v_off_ini = 0.000002980 V, v_off_fin = 0.000005608 V 21:14:17 Integrated Voltage Measurement Delta Gap = 0.0040034 m VT = 0.175528195 Vs 21:14:17 Integrated Voltage Measurement... 21:14:36 Voltage Offset Correction: v_off_ini = 0.000004532 V, v_off_fin = -0.000002824 V 21:14:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175316783 Vs 21:14:39 Temperature Measurement, Probe Number = 0, T = 20.275000 C 21:14:40 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:14:40 Temperature Measurement, Probe Number = 2, T = 19.984000 C 21:14:41 Temperature Measurement, Probe Number = 3, T = 19.972000 C 21:14:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 21:14:41 Integrated Voltage Measurement... 21:15:00 Voltage Offset Correction: v_off_ini = 0.000000088 V, v_off_fin = 0.000005366 V 21:15:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426702 Vs 21:15:01 Integrated Voltage Measurement... 21:15:20 Voltage Offset Correction: v_off_ini = 0.000005169 V, v_off_fin = -0.000002533 V 21:15:20 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315263 Vs 21:15:23 Temperature Measurement, Probe Number = 0, T = 20.250000 C 21:15:23 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:15:24 Temperature Measurement, Probe Number = 2, T = 19.986000 C 21:15:25 Temperature Measurement, Probe Number = 3, T = 19.972000 C 21:15:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 21:15:25 Integrated Voltage Measurement... 21:15:44 Voltage Offset Correction: v_off_ini = 0.000000733 V, v_off_fin = 0.000005132 V 21:15:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433050 Vs 21:15:44 Integrated Voltage Measurement... 21:16:03 Voltage Offset Correction: v_off_ini = 0.000004784 V, v_off_fin = -0.000002734 V 21:16:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317629 Vs 21:16:06 Temperature Measurement, Probe Number = 0, T = 20.269000 C 21:16:07 Temperature Measurement, Probe Number = 1, T = 20.015000 C 21:16:08 Temperature Measurement, Probe Number = 2, T = 19.988000 C 21:16:08 Temperature Measurement, Probe Number = 3, T = 19.974000 C 21:16:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 21:16:08 Integrated Voltage Measurement... 21:16:27 Voltage Offset Correction: v_off_ini = 0.000001183 V, v_off_fin = 0.000005345 V 21:16:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429728 Vs 21:16:28 Integrated Voltage Measurement... 21:16:47 Voltage Offset Correction: v_off_ini = 0.000004466 V, v_off_fin = -0.000002832 V 21:16:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313916 Vs 21:16:50 Temperature Measurement, Probe Number = 0, T = 20.298000 C 21:16:50 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:16:51 Temperature Measurement, Probe Number = 2, T = 19.989000 C 21:16:52 Temperature Measurement, Probe Number = 3, T = 19.975000 C 21:16:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:16:52 Integrated Voltage Measurement... 21:17:11 Voltage Offset Correction: v_off_ini = 0.000001005 V, v_off_fin = 0.000005482 V 21:17:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431445 Vs 21:17:11 Integrated Voltage Measurement... 21:17:31 Voltage Offset Correction: v_off_ini = 0.000005097 V, v_off_fin = -0.000002643 V 21:17:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175322115 Vs 21:17:34 Temperature Measurement, Probe Number = 0, T = 20.304000 C 21:17:34 Temperature Measurement, Probe Number = 1, T = 20.013000 C 21:17:35 Temperature Measurement, Probe Number = 2, T = 19.989000 C 21:17:36 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:17:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:17:36 Integrated Voltage Measurement... 21:17:55 Voltage Offset Correction: v_off_ini = 0.000001254 V, v_off_fin = 0.000005247 V 21:17:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175434520 Vs 21:17:55 Integrated Voltage Measurement... 21:18:15 Voltage Offset Correction: v_off_ini = 0.000004679 V, v_off_fin = -0.000002244 V 21:18:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313047 Vs 21:18:18 Temperature Measurement, Probe Number = 0, T = 20.310000 C 21:18:18 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:18:19 Temperature Measurement, Probe Number = 2, T = 19.990000 C 21:18:20 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:18:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:18:20 Integrated Voltage Measurement... 21:18:39 Voltage Offset Correction: v_off_ini = 0.000001014 V, v_off_fin = 0.000005705 V 21:18:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430778 Vs 21:18:39 Integrated Voltage Measurement... 21:18:58 Voltage Offset Correction: v_off_ini = 0.000005569 V, v_off_fin = -0.000002707 V 21:18:58 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175311536 Vs 21:19:01 Temperature Measurement, Probe Number = 0, T = 20.331000 C 21:19:02 Temperature Measurement, Probe Number = 1, T = 20.019000 C 21:19:02 Temperature Measurement, Probe Number = 2, T = 19.991000 C 21:19:03 Temperature Measurement, Probe Number = 3, T = 19.979000 C 21:19:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:19:03 Integrated Voltage Measurement... 21:19:22 Voltage Offset Correction: v_off_ini = 0.000000630 V, v_off_fin = 0.000005632 V 21:19:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175436449 Vs 21:19:22 Integrated Voltage Measurement... 21:19:41 Voltage Offset Correction: v_off_ini = 0.000005051 V, v_off_fin = -0.000002671 V 21:19:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315661 Vs 21:19:44 Temperature Measurement, Probe Number = 0, T = 20.362000 C 21:19:45 Temperature Measurement, Probe Number = 1, T = 20.019000 C 21:19:46 Temperature Measurement, Probe Number = 2, T = 19.992000 C 21:19:46 Temperature Measurement, Probe Number = 3, T = 19.977000 C 21:19:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:19:46 Integrated Voltage Measurement... 21:20:05 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = 0.000005181 V 21:20:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430084 Vs 21:20:06 Integrated Voltage Measurement... 21:20:25 Voltage Offset Correction: v_off_ini = 0.000004646 V, v_off_fin = -0.000002575 V 21:20:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317230 Vs 21:20:28 Temperature Measurement, Probe Number = 0, T = 20.372000 C 21:20:29 Temperature Measurement, Probe Number = 1, T = 20.020000 C 21:20:29 Temperature Measurement, Probe Number = 2, T = 19.993000 C 21:20:30 Temperature Measurement, Probe Number = 3, T = 19.978000 C 21:20:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:20:30 Integrated Voltage Measurement... 21:20:49 Voltage Offset Correction: v_off_ini = 0.000001015 V, v_off_fin = 0.000005037 V 21:20:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430108 Vs 21:20:50 Integrated Voltage Measurement... 21:21:09 Voltage Offset Correction: v_off_ini = 0.000004634 V, v_off_fin = -0.000002854 V 21:21:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315224 Vs 21:51:11 Temperature Measurement, Probe Number = 0, T = 20.304000 C 21:51:12 Temperature Measurement, Probe Number = 1, T = 20.011000 C 21:51:13 Temperature Measurement, Probe Number = 2, T = 19.981000 C 21:51:13 Temperature Measurement, Probe Number = 3, T = 19.971000 C 21:51:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 21:51:14 Integrated Voltage Measurement... 21:51:33 Voltage Offset Correction: v_off_ini = 0.000003363 V, v_off_fin = 0.000005460 V 21:51:33 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175534142 Vs 21:51:33 Integrated Voltage Measurement... 21:51:52 Voltage Offset Correction: v_off_ini = 0.000004616 V, v_off_fin = -0.000002795 V 21:51:52 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175310277 Vs 21:51:55 Temperature Measurement, Probe Number = 0, T = 20.282000 C 21:51:56 Temperature Measurement, Probe Number = 1, T = 20.012000 C 21:51:56 Temperature Measurement, Probe Number = 2, T = 19.984000 C 21:51:57 Temperature Measurement, Probe Number = 3, T = 19.975000 C 21:51:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 21:51:57 Integrated Voltage Measurement... 21:52:16 Voltage Offset Correction: v_off_ini = 0.000000635 V, v_off_fin = 0.000005714 V 21:52:16 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429880 Vs 21:52:16 Integrated Voltage Measurement... 21:52:36 Voltage Offset Correction: v_off_ini = 0.000004975 V, v_off_fin = -0.000001679 V 21:52:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315631 Vs 21:52:39 Temperature Measurement, Probe Number = 0, T = 20.291000 C 21:52:39 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:52:40 Temperature Measurement, Probe Number = 2, T = 19.986000 C 21:52:41 Temperature Measurement, Probe Number = 3, T = 19.974000 C 21:52:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 21:52:41 Integrated Voltage Measurement... 21:53:00 Voltage Offset Correction: v_off_ini = 0.000001673 V, v_off_fin = 0.000005888 V 21:53:00 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426352 Vs 21:53:00 Integrated Voltage Measurement... 21:53:19 Voltage Offset Correction: v_off_ini = 0.000004903 V, v_off_fin = -0.000002720 V 21:53:19 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308786 Vs 21:53:22 Temperature Measurement, Probe Number = 0, T = 20.359000 C 21:53:23 Temperature Measurement, Probe Number = 1, T = 20.013000 C 21:53:23 Temperature Measurement, Probe Number = 2, T = 19.987000 C 21:53:24 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:53:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:53:24 Integrated Voltage Measurement... 21:53:43 Voltage Offset Correction: v_off_ini = 0.000000835 V, v_off_fin = 0.000005772 V 21:53:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175431701 Vs 21:53:44 Integrated Voltage Measurement... 21:54:03 Voltage Offset Correction: v_off_ini = 0.000004918 V, v_off_fin = -0.000003043 V 21:54:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309991 Vs 21:54:06 Temperature Measurement, Probe Number = 0, T = 20.372000 C 21:54:07 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:54:07 Temperature Measurement, Probe Number = 2, T = 19.985000 C 21:54:08 Temperature Measurement, Probe Number = 3, T = 19.975000 C 21:54:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 21:54:08 Integrated Voltage Measurement... 21:54:27 Voltage Offset Correction: v_off_ini = 0.000001165 V, v_off_fin = 0.000005421 V 21:54:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426236 Vs 21:54:28 Integrated Voltage Measurement... 21:54:47 Voltage Offset Correction: v_off_ini = 0.000004991 V, v_off_fin = -0.000002721 V 21:54:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317580 Vs 21:54:50 Temperature Measurement, Probe Number = 0, T = 20.354000 C 21:54:51 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:54:51 Temperature Measurement, Probe Number = 2, T = 19.987000 C 21:54:52 Temperature Measurement, Probe Number = 3, T = 19.975000 C 21:54:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:54:52 Integrated Voltage Measurement... 21:55:11 Voltage Offset Correction: v_off_ini = 0.000001283 V, v_off_fin = 0.000005569 V 21:55:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422877 Vs 21:55:11 Integrated Voltage Measurement... 21:55:30 Voltage Offset Correction: v_off_ini = 0.000005026 V, v_off_fin = -0.000002085 V 21:55:31 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308508 Vs 21:55:33 Temperature Measurement, Probe Number = 0, T = 20.369000 C 21:55:34 Temperature Measurement, Probe Number = 1, T = 20.015000 C 21:55:35 Temperature Measurement, Probe Number = 2, T = 19.987000 C 21:55:35 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:55:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:55:35 Integrated Voltage Measurement... 21:55:55 Voltage Offset Correction: v_off_ini = 0.000001137 V, v_off_fin = 0.000005657 V 21:55:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175432028 Vs 21:55:55 Integrated Voltage Measurement... 21:56:14 Voltage Offset Correction: v_off_ini = 0.000004935 V, v_off_fin = -0.000002167 V 21:56:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309528 Vs 21:56:17 Temperature Measurement, Probe Number = 0, T = 20.392000 C 21:56:18 Temperature Measurement, Probe Number = 1, T = 20.014000 C 21:56:18 Temperature Measurement, Probe Number = 2, T = 19.986000 C 21:56:19 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:56:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.98 21:56:19 Integrated Voltage Measurement... 21:56:39 Voltage Offset Correction: v_off_ini = 0.000001480 V, v_off_fin = 0.000005205 V 21:56:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428072 Vs 21:56:39 Integrated Voltage Measurement... 21:56:58 Voltage Offset Correction: v_off_ini = 0.000004623 V, v_off_fin = -0.000002070 V 21:56:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315106 Vs 21:57:01 Temperature Measurement, Probe Number = 0, T = 20.350000 C 21:57:02 Temperature Measurement, Probe Number = 1, T = 20.015000 C 21:57:02 Temperature Measurement, Probe Number = 2, T = 19.984000 C 21:57:03 Temperature Measurement, Probe Number = 3, T = 19.976000 C 21:57:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 21:57:03 Integrated Voltage Measurement... 21:57:23 Voltage Offset Correction: v_off_ini = 0.000000900 V, v_off_fin = 0.000005803 V 21:57:23 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428471 Vs 21:57:23 Integrated Voltage Measurement... 21:57:42 Voltage Offset Correction: v_off_ini = 0.000005129 V, v_off_fin = -0.000003309 V 21:57:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175321162 Vs 21:57:45 Temperature Measurement, Probe Number = 0, T = 20.335000 C 21:57:46 Temperature Measurement, Probe Number = 1, T = 20.012000 C 21:57:46 Temperature Measurement, Probe Number = 2, T = 19.983000 C 21:57:47 Temperature Measurement, Probe Number = 3, T = 19.973000 C 21:57:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 21:57:47 Integrated Voltage Measurement... 21:58:07 Voltage Offset Correction: v_off_ini = 0.000000817 V, v_off_fin = 0.000005696 V 21:58:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427982 Vs 21:58:07 Integrated Voltage Measurement... 21:58:26 Voltage Offset Correction: v_off_ini = 0.000004607 V, v_off_fin = -0.000001655 V 21:58:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312982 Vs 22:28:29 Temperature Measurement, Probe Number = 0, T = 20.191000 C 22:28:30 Temperature Measurement, Probe Number = 1, T = 20.008000 C 22:28:31 Temperature Measurement, Probe Number = 2, T = 19.977000 C 22:28:31 Temperature Measurement, Probe Number = 3, T = 19.969000 C 22:28:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:28:32 Integrated Voltage Measurement... 22:28:50 Voltage Offset Correction: v_off_ini = 0.000003456 V, v_off_fin = 0.000005115 V 22:28:51 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175513807 Vs 22:28:51 Integrated Voltage Measurement... 22:29:10 Voltage Offset Correction: v_off_ini = 0.000004922 V, v_off_fin = -0.000002210 V 22:29:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313933 Vs 22:29:13 Temperature Measurement, Probe Number = 0, T = 20.254000 C 22:29:14 Temperature Measurement, Probe Number = 1, T = 20.011000 C 22:29:14 Temperature Measurement, Probe Number = 2, T = 19.980000 C 22:29:15 Temperature Measurement, Probe Number = 3, T = 19.973000 C 22:29:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:29:15 Integrated Voltage Measurement... 22:29:34 Voltage Offset Correction: v_off_ini = 0.000001512 V, v_off_fin = 0.000005576 V 22:29:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427176 Vs 22:29:34 Integrated Voltage Measurement... 22:29:54 Voltage Offset Correction: v_off_ini = 0.000004780 V, v_off_fin = -0.000002144 V 22:29:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302017 Vs 22:29:56 Temperature Measurement, Probe Number = 0, T = 20.305000 C 22:29:57 Temperature Measurement, Probe Number = 1, T = 20.014000 C 22:29:58 Temperature Measurement, Probe Number = 2, T = 19.983000 C 22:29:58 Temperature Measurement, Probe Number = 3, T = 19.975000 C 22:29:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 22:29:59 Integrated Voltage Measurement... 22:30:18 Voltage Offset Correction: v_off_ini = 0.000001246 V, v_off_fin = 0.000005862 V 22:30:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430071 Vs 22:30:18 Integrated Voltage Measurement... 22:30:37 Voltage Offset Correction: v_off_ini = 0.000004933 V, v_off_fin = -0.000003175 V 22:30:37 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309037 Vs 22:30:40 Temperature Measurement, Probe Number = 0, T = 20.293000 C 22:30:40 Temperature Measurement, Probe Number = 1, T = 20.011000 C 22:30:41 Temperature Measurement, Probe Number = 2, T = 19.980000 C 22:30:42 Temperature Measurement, Probe Number = 3, T = 19.970000 C 22:30:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:30:42 Integrated Voltage Measurement... 22:31:01 Voltage Offset Correction: v_off_ini = 0.000001442 V, v_off_fin = 0.000005642 V 22:31:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434200 Vs 22:31:01 Integrated Voltage Measurement... 22:31:20 Voltage Offset Correction: v_off_ini = 0.000005078 V, v_off_fin = -0.000001776 V 22:31:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312129 Vs 22:31:23 Temperature Measurement, Probe Number = 0, T = 20.277000 C 22:31:24 Temperature Measurement, Probe Number = 1, T = 20.012000 C 22:31:24 Temperature Measurement, Probe Number = 2, T = 19.983000 C 22:31:25 Temperature Measurement, Probe Number = 3, T = 19.972000 C 22:31:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:31:25 Integrated Voltage Measurement... 22:31:45 Voltage Offset Correction: v_off_ini = 0.000001387 V, v_off_fin = 0.000005213 V 22:31:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423800 Vs 22:31:45 Integrated Voltage Measurement... 22:32:05 Voltage Offset Correction: v_off_ini = 0.000004780 V, v_off_fin = -0.000002496 V 22:32:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313822 Vs 22:32:07 Temperature Measurement, Probe Number = 0, T = 20.313000 C 22:32:08 Temperature Measurement, Probe Number = 1, T = 20.014000 C 22:32:09 Temperature Measurement, Probe Number = 2, T = 19.983000 C 22:32:09 Temperature Measurement, Probe Number = 3, T = 19.973000 C 22:32:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:32:10 Integrated Voltage Measurement... 22:32:29 Voltage Offset Correction: v_off_ini = 0.000001450 V, v_off_fin = 0.000006057 V 22:32:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429383 Vs 22:32:29 Integrated Voltage Measurement... 22:32:49 Voltage Offset Correction: v_off_ini = 0.000005001 V, v_off_fin = -0.000001375 V 22:32:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308788 Vs 22:32:51 Temperature Measurement, Probe Number = 0, T = 20.280000 C 22:32:52 Temperature Measurement, Probe Number = 1, T = 20.011000 C 22:32:53 Temperature Measurement, Probe Number = 2, T = 19.980000 C 22:32:53 Temperature Measurement, Probe Number = 3, T = 19.970000 C 22:32:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:32:54 Integrated Voltage Measurement... 22:33:13 Voltage Offset Correction: v_off_ini = 0.000001462 V, v_off_fin = 0.000005285 V 22:33:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425085 Vs 22:33:13 Integrated Voltage Measurement... 22:33:32 Voltage Offset Correction: v_off_ini = 0.000004603 V, v_off_fin = -0.000002857 V 22:33:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309885 Vs 22:33:35 Temperature Measurement, Probe Number = 0, T = 20.283000 C 22:33:36 Temperature Measurement, Probe Number = 1, T = 20.010000 C 22:33:36 Temperature Measurement, Probe Number = 2, T = 19.983000 C 22:33:37 Temperature Measurement, Probe Number = 3, T = 19.973000 C 22:33:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:33:37 Integrated Voltage Measurement... 22:33:56 Voltage Offset Correction: v_off_ini = 0.000001115 V, v_off_fin = 0.000005510 V 22:33:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175430893 Vs 22:33:56 Integrated Voltage Measurement... 22:34:16 Voltage Offset Correction: v_off_ini = 0.000004660 V, v_off_fin = -0.000002638 V 22:34:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313015 Vs 22:34:18 Temperature Measurement, Probe Number = 0, T = 20.284000 C 22:34:19 Temperature Measurement, Probe Number = 1, T = 20.012000 C 22:34:20 Temperature Measurement, Probe Number = 2, T = 19.983000 C 22:34:20 Temperature Measurement, Probe Number = 3, T = 19.973000 C 22:34:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:34:20 Integrated Voltage Measurement... 22:34:40 Voltage Offset Correction: v_off_ini = 0.000000561 V, v_off_fin = 0.000005836 V 22:34:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175428625 Vs 22:34:40 Integrated Voltage Measurement... 22:34:59 Voltage Offset Correction: v_off_ini = 0.000004681 V, v_off_fin = -0.000002830 V 22:34:59 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309262 Vs 22:35:02 Temperature Measurement, Probe Number = 0, T = 20.252000 C 22:35:03 Temperature Measurement, Probe Number = 1, T = 20.012000 C 22:35:03 Temperature Measurement, Probe Number = 2, T = 19.978000 C 22:35:04 Temperature Measurement, Probe Number = 3, T = 19.971000 C 22:35:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 22:35:04 Integrated Voltage Measurement... 22:35:23 Voltage Offset Correction: v_off_ini = 0.000000835 V, v_off_fin = 0.000005488 V 22:35:23 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425694 Vs 22:35:24 Integrated Voltage Measurement... 22:35:43 Voltage Offset Correction: v_off_ini = 0.000005197 V, v_off_fin = -0.000002248 V 22:35:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307847 Vs 23:05:46 Temperature Measurement, Probe Number = 0, T = 20.353000 C 23:05:47 Temperature Measurement, Probe Number = 1, T = 20.012000 C 23:05:47 Temperature Measurement, Probe Number = 2, T = 19.984000 C 23:05:48 Temperature Measurement, Probe Number = 3, T = 19.975000 C 23:05:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 23:05:48 Integrated Voltage Measurement... 23:06:08 Voltage Offset Correction: v_off_ini = 0.000003667 V, v_off_fin = 0.000005415 V 23:06:08 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175519963 Vs 23:06:08 Integrated Voltage Measurement... 23:06:27 Voltage Offset Correction: v_off_ini = 0.000004722 V, v_off_fin = -0.000002634 V 23:06:27 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302083 Vs 23:06:30 Temperature Measurement, Probe Number = 0, T = 20.378000 C 23:06:31 Temperature Measurement, Probe Number = 1, T = 20.012000 C 23:06:31 Temperature Measurement, Probe Number = 2, T = 19.985000 C 23:06:32 Temperature Measurement, Probe Number = 3, T = 19.975000 C 23:06:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.98 23:06:32 Integrated Voltage Measurement... 23:06:51 Voltage Offset Correction: v_off_ini = 0.000000329 V, v_off_fin = 0.000005585 V 23:06:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418909 Vs 23:06:51 Integrated Voltage Measurement... 23:07:11 Voltage Offset Correction: v_off_ini = 0.000005314 V, v_off_fin = -0.000002317 V 23:07:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308809 Vs 23:07:14 Temperature Measurement, Probe Number = 0, T = 20.343000 C 23:07:14 Temperature Measurement, Probe Number = 1, T = 20.012000 C 23:07:15 Temperature Measurement, Probe Number = 2, T = 19.982000 C 23:07:16 Temperature Measurement, Probe Number = 3, T = 19.972000 C 23:07:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:07:16 Integrated Voltage Measurement... 23:07:35 Voltage Offset Correction: v_off_ini = 0.000001164 V, v_off_fin = 0.000005644 V 23:07:35 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419728 Vs 23:07:35 Integrated Voltage Measurement... 23:07:55 Voltage Offset Correction: v_off_ini = 0.000004686 V, v_off_fin = -0.000002473 V 23:07:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316714 Vs 23:07:58 Temperature Measurement, Probe Number = 0, T = 20.262000 C 23:07:58 Temperature Measurement, Probe Number = 1, T = 20.012000 C 23:07:59 Temperature Measurement, Probe Number = 2, T = 19.980000 C 23:08:00 Temperature Measurement, Probe Number = 3, T = 19.972000 C 23:08:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:08:00 Integrated Voltage Measurement... 23:08:19 Voltage Offset Correction: v_off_ini = 0.000001062 V, v_off_fin = 0.000005010 V 23:08:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422725 Vs 23:08:19 Integrated Voltage Measurement... 23:08:39 Voltage Offset Correction: v_off_ini = 0.000004237 V, v_off_fin = -0.000002206 V 23:08:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315372 Vs 23:08:42 Temperature Measurement, Probe Number = 0, T = 20.288000 C 23:08:42 Temperature Measurement, Probe Number = 1, T = 20.014000 C 23:08:43 Temperature Measurement, Probe Number = 2, T = 19.983000 C 23:08:44 Temperature Measurement, Probe Number = 3, T = 19.973000 C 23:08:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:08:44 Integrated Voltage Measurement... 23:09:04 Voltage Offset Correction: v_off_ini = 0.000001500 V, v_off_fin = 0.000005483 V 23:09:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422118 Vs 23:09:04 Integrated Voltage Measurement... 23:09:23 Voltage Offset Correction: v_off_ini = 0.000004624 V, v_off_fin = -0.000003364 V 23:09:23 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306265 Vs 23:09:26 Temperature Measurement, Probe Number = 0, T = 20.342000 C 23:09:27 Temperature Measurement, Probe Number = 1, T = 20.014000 C 23:09:27 Temperature Measurement, Probe Number = 2, T = 19.983000 C 23:09:28 Temperature Measurement, Probe Number = 3, T = 19.973000 C 23:09:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:09:28 Integrated Voltage Measurement... 23:09:47 Voltage Offset Correction: v_off_ini = 0.000001098 V, v_off_fin = 0.000005497 V 23:09:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422954 Vs 23:09:48 Integrated Voltage Measurement... 23:10:06 Voltage Offset Correction: v_off_ini = 0.000004702 V, v_off_fin = -0.000002483 V 23:10:07 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175309430 Vs 23:10:09 Temperature Measurement, Probe Number = 0, T = 20.373000 C 23:10:10 Temperature Measurement, Probe Number = 1, T = 20.014000 C 23:10:11 Temperature Measurement, Probe Number = 2, T = 19.985000 C 23:10:11 Temperature Measurement, Probe Number = 3, T = 19.973000 C 23:10:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:10:11 Integrated Voltage Measurement... 23:10:30 Voltage Offset Correction: v_off_ini = 0.000000927 V, v_off_fin = 0.000006344 V 23:10:31 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423718 Vs 23:10:31 Integrated Voltage Measurement... 23:10:50 Voltage Offset Correction: v_off_ini = 0.000004877 V, v_off_fin = -0.000002335 V 23:10:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308415 Vs 23:10:53 Temperature Measurement, Probe Number = 0, T = 20.388000 C 23:10:54 Temperature Measurement, Probe Number = 1, T = 20.014000 C 23:10:54 Temperature Measurement, Probe Number = 2, T = 19.988000 C 23:10:55 Temperature Measurement, Probe Number = 3, T = 19.972000 C 23:10:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:10:55 Integrated Voltage Measurement... 23:11:14 Voltage Offset Correction: v_off_ini = 0.000000837 V, v_off_fin = 0.000005510 V 23:11:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418282 Vs 23:11:15 Integrated Voltage Measurement... 23:11:35 Voltage Offset Correction: v_off_ini = 0.000004680 V, v_off_fin = -0.000001862 V 23:11:35 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175309802 Vs 23:11:38 Temperature Measurement, Probe Number = 0, T = 20.400000 C 23:11:39 Temperature Measurement, Probe Number = 1, T = 20.015000 C 23:11:39 Temperature Measurement, Probe Number = 2, T = 19.987000 C 23:11:40 Temperature Measurement, Probe Number = 3, T = 19.974000 C 23:11:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:11:40 Integrated Voltage Measurement... 23:11:59 Voltage Offset Correction: v_off_ini = 0.000001089 V, v_off_fin = 0.000005229 V 23:12:00 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175404827 Vs 23:12:00 Integrated Voltage Measurement... 23:12:19 Voltage Offset Correction: v_off_ini = 0.000004278 V, v_off_fin = -0.000003231 V 23:12:19 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175314684 Vs 23:12:22 Temperature Measurement, Probe Number = 0, T = 20.410000 C 23:12:23 Temperature Measurement, Probe Number = 1, T = 20.014000 C 23:12:23 Temperature Measurement, Probe Number = 2, T = 19.986000 C 23:12:24 Temperature Measurement, Probe Number = 3, T = 19.974000 C 23:12:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 23:12:25 Integrated Voltage Measurement... 23:12:44 Voltage Offset Correction: v_off_ini = 0.000001261 V, v_off_fin = 0.000005524 V 23:12:44 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175420090 Vs 23:12:44 Integrated Voltage Measurement... 23:13:04 Voltage Offset Correction: v_off_ini = 0.000004760 V, v_off_fin = -0.000002520 V 23:13:04 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301973 Vs 23:43:06 Temperature Measurement, Probe Number = 0, T = 20.159000 C 23:43:07 Temperature Measurement, Probe Number = 1, T = 20.008000 C 23:43:08 Temperature Measurement, Probe Number = 2, T = 19.978000 C 23:43:08 Temperature Measurement, Probe Number = 3, T = 19.967000 C 23:43:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:43:09 Integrated Voltage Measurement... 23:43:28 Voltage Offset Correction: v_off_ini = 0.000003680 V, v_off_fin = 0.000005795 V 23:43:28 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175506852 Vs 23:43:29 Integrated Voltage Measurement... 23:43:47 Voltage Offset Correction: v_off_ini = 0.000004866 V, v_off_fin = -0.000002842 V 23:43:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298215 Vs 23:43:50 Temperature Measurement, Probe Number = 0, T = 20.197000 C 23:43:51 Temperature Measurement, Probe Number = 1, T = 20.008000 C 23:43:52 Temperature Measurement, Probe Number = 2, T = 19.976000 C 23:43:52 Temperature Measurement, Probe Number = 3, T = 19.965000 C 23:43:52 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:43:52 Integrated Voltage Measurement... 23:44:12 Voltage Offset Correction: v_off_ini = 0.000001745 V, v_off_fin = 0.000005945 V 23:44:12 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426057 Vs 23:44:12 Integrated Voltage Measurement... 23:44:31 Voltage Offset Correction: v_off_ini = 0.000005283 V, v_off_fin = -0.000002018 V 23:44:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303517 Vs 23:44:34 Temperature Measurement, Probe Number = 0, T = 20.238000 C 23:44:35 Temperature Measurement, Probe Number = 1, T = 20.006000 C 23:44:35 Temperature Measurement, Probe Number = 2, T = 19.976000 C 23:44:36 Temperature Measurement, Probe Number = 3, T = 19.966000 C 23:44:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:44:36 Integrated Voltage Measurement... 23:44:56 Voltage Offset Correction: v_off_ini = 0.000001020 V, v_off_fin = 0.000005756 V 23:44:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425071 Vs 23:44:56 Integrated Voltage Measurement... 23:45:15 Voltage Offset Correction: v_off_ini = 0.000004626 V, v_off_fin = -0.000002705 V 23:45:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311343 Vs 23:45:18 Temperature Measurement, Probe Number = 0, T = 20.199000 C 23:45:19 Temperature Measurement, Probe Number = 1, T = 20.007000 C 23:45:19 Temperature Measurement, Probe Number = 2, T = 19.976000 C 23:45:20 Temperature Measurement, Probe Number = 3, T = 19.965000 C 23:45:20 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 23:45:20 Integrated Voltage Measurement... 23:45:40 Voltage Offset Correction: v_off_ini = 0.000001599 V, v_off_fin = 0.000005542 V 23:45:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421714 Vs 23:45:40 Integrated Voltage Measurement... 23:45:59 Voltage Offset Correction: v_off_ini = 0.000004908 V, v_off_fin = -0.000002546 V 23:45:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308575 Vs 23:46:02 Temperature Measurement, Probe Number = 0, T = 20.198000 C 23:46:03 Temperature Measurement, Probe Number = 1, T = 20.008000 C 23:46:03 Temperature Measurement, Probe Number = 2, T = 19.979000 C 23:46:04 Temperature Measurement, Probe Number = 3, T = 19.970000 C 23:46:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:46:04 Integrated Voltage Measurement... 23:46:24 Voltage Offset Correction: v_off_ini = 0.000001192 V, v_off_fin = 0.000005723 V 23:46:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423835 Vs 23:46:24 Integrated Voltage Measurement... 23:46:43 Voltage Offset Correction: v_off_ini = 0.000004704 V, v_off_fin = -0.000002634 V 23:46:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310688 Vs 23:46:46 Temperature Measurement, Probe Number = 0, T = 20.235000 C 23:46:47 Temperature Measurement, Probe Number = 1, T = 20.010000 C 23:46:48 Temperature Measurement, Probe Number = 2, T = 19.978000 C 23:46:48 Temperature Measurement, Probe Number = 3, T = 19.973000 C 23:46:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:46:49 Integrated Voltage Measurement... 23:47:08 Voltage Offset Correction: v_off_ini = 0.000001683 V, v_off_fin = 0.000005731 V 23:47:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417550 Vs 23:47:08 Integrated Voltage Measurement... 23:47:27 Voltage Offset Correction: v_off_ini = 0.000005291 V, v_off_fin = -0.000002392 V 23:47:28 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303663 Vs 23:47:30 Temperature Measurement, Probe Number = 0, T = 20.265000 C 23:47:31 Temperature Measurement, Probe Number = 1, T = 20.008000 C 23:47:32 Temperature Measurement, Probe Number = 2, T = 19.978000 C 23:47:32 Temperature Measurement, Probe Number = 3, T = 19.971000 C 23:47:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:47:33 Integrated Voltage Measurement... 23:47:52 Voltage Offset Correction: v_off_ini = 0.000001334 V, v_off_fin = 0.000005407 V 23:47:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175417935 Vs 23:47:52 Integrated Voltage Measurement... 23:48:11 Voltage Offset Correction: v_off_ini = 0.000004556 V, v_off_fin = -0.000002627 V 23:48:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315163 Vs 23:48:14 Temperature Measurement, Probe Number = 0, T = 20.262000 C 23:48:15 Temperature Measurement, Probe Number = 1, T = 20.009000 C 23:48:16 Temperature Measurement, Probe Number = 2, T = 19.979000 C 23:48:16 Temperature Measurement, Probe Number = 3, T = 19.971000 C 23:48:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:48:16 Integrated Voltage Measurement... 23:48:36 Voltage Offset Correction: v_off_ini = 0.000001034 V, v_off_fin = 0.000005687 V 23:48:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415954 Vs 23:48:36 Integrated Voltage Measurement... 23:48:55 Voltage Offset Correction: v_off_ini = 0.000004939 V, v_off_fin = -0.000002149 V 23:48:55 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175297828 Vs 23:48:58 Temperature Measurement, Probe Number = 0, T = 20.221000 C 23:48:58 Temperature Measurement, Probe Number = 1, T = 20.009000 C 23:48:59 Temperature Measurement, Probe Number = 2, T = 19.979000 C 23:49:00 Temperature Measurement, Probe Number = 3, T = 19.969000 C 23:49:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:49:00 Integrated Voltage Measurement... 23:49:19 Voltage Offset Correction: v_off_ini = 0.000001997 V, v_off_fin = 0.000006112 V 23:49:19 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426998 Vs 23:49:19 Integrated Voltage Measurement... 23:49:39 Voltage Offset Correction: v_off_ini = 0.000005475 V, v_off_fin = -0.000002213 V 23:49:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304207 Vs 23:49:42 Temperature Measurement, Probe Number = 0, T = 20.219000 C 23:49:42 Temperature Measurement, Probe Number = 1, T = 20.010000 C 23:49:43 Temperature Measurement, Probe Number = 2, T = 19.981000 C 23:49:44 Temperature Measurement, Probe Number = 3, T = 19.973000 C 23:49:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 23:49:44 Integrated Voltage Measurement... 23:50:03 Voltage Offset Correction: v_off_ini = 0.000001519 V, v_off_fin = 0.000005935 V 23:50:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419405 Vs 23:50:03 Integrated Voltage Measurement... 23:50:23 Voltage Offset Correction: v_off_ini = 0.000004922 V, v_off_fin = -0.000002493 V 23:50:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305591 Vs 00:20:26 Temperature Measurement, Probe Number = 0, T = 20.185000 C 00:20:26 Temperature Measurement, Probe Number = 1, T = 20.005000 C 00:20:27 Temperature Measurement, Probe Number = 2, T = 19.972000 C 00:20:28 Temperature Measurement, Probe Number = 3, T = 19.965000 C 00:20:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 00:20:28 Integrated Voltage Measurement... 00:20:47 Voltage Offset Correction: v_off_ini = 0.000003639 V, v_off_fin = 0.000005404 V 00:20:47 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175509262 Vs 00:20:47 Integrated Voltage Measurement... 00:21:07 Voltage Offset Correction: v_off_ini = 0.000004764 V, v_off_fin = -0.000002498 V 00:21:07 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296410 Vs 00:21:09 Temperature Measurement, Probe Number = 0, T = 20.242000 C 00:21:10 Temperature Measurement, Probe Number = 1, T = 20.006000 C 00:21:11 Temperature Measurement, Probe Number = 2, T = 19.973000 C 00:21:11 Temperature Measurement, Probe Number = 3, T = 19.964000 C 00:21:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 00:21:12 Integrated Voltage Measurement... 00:21:31 Voltage Offset Correction: v_off_ini = 0.000001613 V, v_off_fin = 0.000005181 V 00:21:31 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414186 Vs 00:21:31 Integrated Voltage Measurement... 00:21:51 Voltage Offset Correction: v_off_ini = 0.000004533 V, v_off_fin = -0.000002057 V 00:21:51 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304790 Vs 00:21:53 Temperature Measurement, Probe Number = 0, T = 20.266000 C 00:21:54 Temperature Measurement, Probe Number = 1, T = 20.010000 C 00:21:55 Temperature Measurement, Probe Number = 2, T = 19.978000 C 00:21:55 Temperature Measurement, Probe Number = 3, T = 19.970000 C 00:21:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:21:56 Integrated Voltage Measurement... 00:22:16 Voltage Offset Correction: v_off_ini = 0.000000761 V, v_off_fin = 0.000004672 V 00:22:16 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175414060 Vs 00:22:16 Integrated Voltage Measurement... 00:22:35 Voltage Offset Correction: v_off_ini = 0.000004202 V, v_off_fin = -0.000002737 V 00:22:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303318 Vs 00:22:38 Temperature Measurement, Probe Number = 0, T = 20.274000 C 00:22:38 Temperature Measurement, Probe Number = 1, T = 20.009000 C 00:22:39 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:22:40 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:22:40 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:22:40 Integrated Voltage Measurement... 00:22:59 Voltage Offset Correction: v_off_ini = 0.000001150 V, v_off_fin = 0.000005191 V 00:22:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175411109 Vs 00:22:59 Integrated Voltage Measurement... 00:23:18 Voltage Offset Correction: v_off_ini = 0.000004304 V, v_off_fin = -0.000003551 V 00:23:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307728 Vs 00:23:21 Temperature Measurement, Probe Number = 0, T = 20.289000 C 00:23:22 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:23:22 Temperature Measurement, Probe Number = 2, T = 19.976000 C 00:23:23 Temperature Measurement, Probe Number = 3, T = 19.969000 C 00:23:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:23:23 Integrated Voltage Measurement... 00:23:42 Voltage Offset Correction: v_off_ini = 0.000000750 V, v_off_fin = 0.000004946 V 00:23:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175411963 Vs 00:23:42 Integrated Voltage Measurement... 00:24:02 Voltage Offset Correction: v_off_ini = 0.000004356 V, v_off_fin = -0.000002986 V 00:24:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308064 Vs 00:24:05 Temperature Measurement, Probe Number = 0, T = 20.284000 C 00:24:05 Temperature Measurement, Probe Number = 1, T = 20.007000 C 00:24:06 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:24:07 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:24:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:24:07 Integrated Voltage Measurement... 00:24:27 Voltage Offset Correction: v_off_ini = 0.000001627 V, v_off_fin = 0.000005581 V 00:24:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175420525 Vs 00:24:27 Integrated Voltage Measurement... 00:24:46 Voltage Offset Correction: v_off_ini = 0.000004347 V, v_off_fin = -0.000002428 V 00:24:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305780 Vs 00:24:49 Temperature Measurement, Probe Number = 0, T = 20.306000 C 00:24:50 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:24:50 Temperature Measurement, Probe Number = 2, T = 19.979000 C 00:24:51 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:24:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:24:51 Integrated Voltage Measurement... 00:25:10 Voltage Offset Correction: v_off_ini = 0.000001161 V, v_off_fin = 0.000006025 V 00:25:11 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425618 Vs 00:25:11 Integrated Voltage Measurement... 00:25:30 Voltage Offset Correction: v_off_ini = 0.000005436 V, v_off_fin = -0.000001151 V 00:25:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296684 Vs 00:25:33 Temperature Measurement, Probe Number = 0, T = 20.306000 C 00:25:34 Temperature Measurement, Probe Number = 1, T = 20.009000 C 00:25:34 Temperature Measurement, Probe Number = 2, T = 19.980000 C 00:25:35 Temperature Measurement, Probe Number = 3, T = 19.967000 C 00:25:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:25:35 Integrated Voltage Measurement... 00:25:54 Voltage Offset Correction: v_off_ini = 0.000001891 V, v_off_fin = 0.000005999 V 00:25:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424050 Vs 00:25:54 Integrated Voltage Measurement... 00:26:13 Voltage Offset Correction: v_off_ini = 0.000005268 V, v_off_fin = -0.000002413 V 00:26:14 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175291720 Vs 00:26:16 Temperature Measurement, Probe Number = 0, T = 20.339000 C 00:26:17 Temperature Measurement, Probe Number = 1, T = 20.009000 C 00:26:18 Temperature Measurement, Probe Number = 2, T = 19.979000 C 00:26:18 Temperature Measurement, Probe Number = 3, T = 19.966000 C 00:26:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:26:18 Integrated Voltage Measurement... 00:26:37 Voltage Offset Correction: v_off_ini = 0.000001204 V, v_off_fin = 0.000006239 V 00:26:38 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175427713 Vs 00:26:38 Integrated Voltage Measurement... 00:26:57 Voltage Offset Correction: v_off_ini = 0.000005277 V, v_off_fin = -0.000001880 V 00:26:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301825 Vs 00:27:00 Temperature Measurement, Probe Number = 0, T = 20.341000 C 00:27:01 Temperature Measurement, Probe Number = 1, T = 20.010000 C 00:27:01 Temperature Measurement, Probe Number = 2, T = 19.982000 C 00:27:02 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:27:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:27:02 Integrated Voltage Measurement... 00:27:21 Voltage Offset Correction: v_off_ini = 0.000001352 V, v_off_fin = 0.000005332 V 00:27:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420816 Vs 00:27:22 Integrated Voltage Measurement... 00:27:41 Voltage Offset Correction: v_off_ini = 0.000004781 V, v_off_fin = -0.000002094 V 00:27:41 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306865 Vs 00:57:44 Temperature Measurement, Probe Number = 0, T = 20.258000 C 00:57:45 Temperature Measurement, Probe Number = 1, T = 20.005000 C 00:57:45 Temperature Measurement, Probe Number = 2, T = 19.977000 C 00:57:46 Temperature Measurement, Probe Number = 3, T = 19.966000 C 00:57:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:57:46 Integrated Voltage Measurement... 00:58:05 Voltage Offset Correction: v_off_ini = 0.000004204 V, v_off_fin = 0.000006131 V 00:58:05 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175515678 Vs 00:58:06 Integrated Voltage Measurement... 00:58:25 Voltage Offset Correction: v_off_ini = 0.000005202 V, v_off_fin = -0.000001922 V 00:58:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303593 Vs 00:58:28 Temperature Measurement, Probe Number = 0, T = 20.277000 C 00:58:29 Temperature Measurement, Probe Number = 1, T = 20.008000 C 00:58:30 Temperature Measurement, Probe Number = 2, T = 19.979000 C 00:58:30 Temperature Measurement, Probe Number = 3, T = 19.966000 C 00:58:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:58:30 Integrated Voltage Measurement... 00:58:50 Voltage Offset Correction: v_off_ini = 0.000001943 V, v_off_fin = 0.000005770 V 00:58:50 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175416200 Vs 00:58:50 Integrated Voltage Measurement... 00:59:09 Voltage Offset Correction: v_off_ini = 0.000005257 V, v_off_fin = -0.000001982 V 00:59:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298270 Vs 00:59:12 Temperature Measurement, Probe Number = 0, T = 20.269000 C 00:59:13 Temperature Measurement, Probe Number = 1, T = 20.006000 C 00:59:13 Temperature Measurement, Probe Number = 2, T = 19.979000 C 00:59:14 Temperature Measurement, Probe Number = 3, T = 19.968000 C 00:59:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:59:14 Integrated Voltage Measurement... 00:59:33 Voltage Offset Correction: v_off_ini = 0.000001188 V, v_off_fin = 0.000006141 V 00:59:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421113 Vs 00:59:34 Integrated Voltage Measurement... 00:59:53 Voltage Offset Correction: v_off_ini = 0.000005501 V, v_off_fin = -0.000002245 V 00:59:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175303881 Vs 00:59:56 Temperature Measurement, Probe Number = 0, T = 20.298000 C 00:59:57 Temperature Measurement, Probe Number = 1, T = 20.006000 C 00:59:57 Temperature Measurement, Probe Number = 2, T = 19.980000 C 00:59:58 Temperature Measurement, Probe Number = 3, T = 19.970000 C 00:59:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 00:59:58 Integrated Voltage Measurement... 01:00:17 Voltage Offset Correction: v_off_ini = 0.000002167 V, v_off_fin = 0.000006071 V 01:00:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421958 Vs 01:00:18 Integrated Voltage Measurement... 01:00:37 Voltage Offset Correction: v_off_ini = 0.000004965 V, v_off_fin = -0.000001432 V 01:00:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293365 Vs 01:00:40 Temperature Measurement, Probe Number = 0, T = 20.326000 C 01:00:40 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:00:41 Temperature Measurement, Probe Number = 2, T = 19.977000 C 01:00:42 Temperature Measurement, Probe Number = 3, T = 19.967000 C 01:00:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:00:42 Integrated Voltage Measurement... 01:01:01 Voltage Offset Correction: v_off_ini = 0.000001381 V, v_off_fin = 0.000006591 V 01:01:01 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429511 Vs 01:01:02 Integrated Voltage Measurement... 01:01:21 Voltage Offset Correction: v_off_ini = 0.000005329 V, v_off_fin = -0.000002413 V 01:01:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292822 Vs 01:01:24 Temperature Measurement, Probe Number = 0, T = 20.310000 C 01:01:24 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:01:25 Temperature Measurement, Probe Number = 2, T = 19.979000 C 01:01:26 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:01:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:01:26 Integrated Voltage Measurement... 01:01:45 Voltage Offset Correction: v_off_ini = 0.000002018 V, v_off_fin = 0.000005882 V 01:01:45 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426850 Vs 01:01:45 Integrated Voltage Measurement... 01:02:04 Voltage Offset Correction: v_off_ini = 0.000005445 V, v_off_fin = -0.000002853 V 01:02:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302182 Vs 01:02:07 Temperature Measurement, Probe Number = 0, T = 20.332000 C 01:02:08 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:02:08 Temperature Measurement, Probe Number = 2, T = 19.974000 C 01:02:09 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:02:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:02:09 Integrated Voltage Measurement... 01:02:29 Voltage Offset Correction: v_off_ini = 0.000001747 V, v_off_fin = 0.000006027 V 01:02:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430623 Vs 01:02:29 Integrated Voltage Measurement... 01:02:48 Voltage Offset Correction: v_off_ini = 0.000004792 V, v_off_fin = -0.000002612 V 01:02:49 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302134 Vs 01:02:51 Temperature Measurement, Probe Number = 0, T = 20.310000 C 01:02:52 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:02:53 Temperature Measurement, Probe Number = 2, T = 19.974000 C 01:02:53 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:02:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:02:53 Integrated Voltage Measurement... 01:03:13 Voltage Offset Correction: v_off_ini = 0.000001622 V, v_off_fin = 0.000005857 V 01:03:13 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431344 Vs 01:03:13 Integrated Voltage Measurement... 01:03:32 Voltage Offset Correction: v_off_ini = 0.000004736 V, v_off_fin = -0.000002033 V 01:03:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303130 Vs 01:03:35 Temperature Measurement, Probe Number = 0, T = 20.286000 C 01:03:36 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:03:36 Temperature Measurement, Probe Number = 2, T = 19.975000 C 01:03:37 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:03:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:03:37 Integrated Voltage Measurement... 01:03:56 Voltage Offset Correction: v_off_ini = 0.000001949 V, v_off_fin = 0.000006429 V 01:03:57 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430111 Vs 01:03:57 Integrated Voltage Measurement... 01:04:16 Voltage Offset Correction: v_off_ini = 0.000005675 V, v_off_fin = -0.000001787 V 01:04:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293237 Vs 01:04:19 Temperature Measurement, Probe Number = 0, T = 20.279000 C 01:04:19 Temperature Measurement, Probe Number = 1, T = 20.004000 C 01:04:20 Temperature Measurement, Probe Number = 2, T = 19.971000 C 01:04:21 Temperature Measurement, Probe Number = 3, T = 19.963000 C 01:04:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 01:04:21 Integrated Voltage Measurement... 01:04:40 Voltage Offset Correction: v_off_ini = 0.000002135 V, v_off_fin = 0.000005663 V 01:04:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175435618 Vs 01:04:40 Integrated Voltage Measurement... 01:05:00 Voltage Offset Correction: v_off_ini = 0.000005279 V, v_off_fin = -0.000002224 V 01:05:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310068 Vs 01:35:02 Temperature Measurement, Probe Number = 0, T = 20.239000 C 01:35:03 Temperature Measurement, Probe Number = 1, T = 20.005000 C 01:35:04 Temperature Measurement, Probe Number = 2, T = 19.978000 C 01:35:04 Temperature Measurement, Probe Number = 3, T = 19.963000 C 01:35:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:35:05 Integrated Voltage Measurement... 01:35:24 Voltage Offset Correction: v_off_ini = 0.000003369 V, v_off_fin = 0.000005485 V 01:35:24 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175511032 Vs 01:35:24 Integrated Voltage Measurement... 01:35:44 Voltage Offset Correction: v_off_ini = 0.000004789 V, v_off_fin = -0.000002206 V 01:35:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175301286 Vs 01:35:47 Temperature Measurement, Probe Number = 0, T = 20.214000 C 01:35:47 Temperature Measurement, Probe Number = 1, T = 20.006000 C 01:35:48 Temperature Measurement, Probe Number = 2, T = 19.980000 C 01:35:49 Temperature Measurement, Probe Number = 3, T = 19.963000 C 01:35:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:35:49 Integrated Voltage Measurement... 01:36:08 Voltage Offset Correction: v_off_ini = 0.000001088 V, v_off_fin = 0.000005793 V 01:36:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410515 Vs 01:36:08 Integrated Voltage Measurement... 01:36:28 Voltage Offset Correction: v_off_ini = 0.000004825 V, v_off_fin = -0.000002830 V 01:36:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306047 Vs 01:36:30 Temperature Measurement, Probe Number = 0, T = 20.238000 C 01:36:31 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:36:32 Temperature Measurement, Probe Number = 2, T = 19.977000 C 01:36:32 Temperature Measurement, Probe Number = 3, T = 19.962000 C 01:36:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:36:33 Integrated Voltage Measurement... 01:36:52 Voltage Offset Correction: v_off_ini = 0.000001525 V, v_off_fin = 0.000006211 V 01:36:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175418473 Vs 01:36:52 Integrated Voltage Measurement... 01:37:11 Voltage Offset Correction: v_off_ini = 0.000004841 V, v_off_fin = -0.000002333 V 01:37:11 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175297090 Vs 01:37:14 Temperature Measurement, Probe Number = 0, T = 20.276000 C 01:37:15 Temperature Measurement, Probe Number = 1, T = 20.005000 C 01:37:15 Temperature Measurement, Probe Number = 2, T = 19.978000 C 01:37:16 Temperature Measurement, Probe Number = 3, T = 19.963000 C 01:37:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:37:16 Integrated Voltage Measurement... 01:37:35 Voltage Offset Correction: v_off_ini = 0.000001657 V, v_off_fin = 0.000005677 V 01:37:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423780 Vs 01:37:36 Integrated Voltage Measurement... 01:37:55 Voltage Offset Correction: v_off_ini = 0.000004578 V, v_off_fin = -0.000002232 V 01:37:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298859 Vs 01:37:58 Temperature Measurement, Probe Number = 0, T = 20.279000 C 01:37:58 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:37:59 Temperature Measurement, Probe Number = 2, T = 19.979000 C 01:38:00 Temperature Measurement, Probe Number = 3, T = 19.966000 C 01:38:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:38:00 Integrated Voltage Measurement... 01:38:19 Voltage Offset Correction: v_off_ini = 0.000001440 V, v_off_fin = 0.000005478 V 01:38:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427601 Vs 01:38:19 Integrated Voltage Measurement... 01:38:39 Voltage Offset Correction: v_off_ini = 0.000004707 V, v_off_fin = -0.000002719 V 01:38:39 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306003 Vs 01:38:42 Temperature Measurement, Probe Number = 0, T = 20.302000 C 01:38:42 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:38:43 Temperature Measurement, Probe Number = 2, T = 19.975000 C 01:38:44 Temperature Measurement, Probe Number = 3, T = 19.966000 C 01:38:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:38:44 Integrated Voltage Measurement... 01:39:03 Voltage Offset Correction: v_off_ini = 0.000001648 V, v_off_fin = 0.000005779 V 01:39:03 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427856 Vs 01:39:03 Integrated Voltage Measurement... 01:39:22 Voltage Offset Correction: v_off_ini = 0.000005141 V, v_off_fin = -0.000002478 V 01:39:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296382 Vs 01:39:25 Temperature Measurement, Probe Number = 0, T = 20.236000 C 01:39:26 Temperature Measurement, Probe Number = 1, T = 20.008000 C 01:39:26 Temperature Measurement, Probe Number = 2, T = 19.978000 C 01:39:27 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:39:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:39:27 Integrated Voltage Measurement... 01:39:46 Voltage Offset Correction: v_off_ini = 0.000000874 V, v_off_fin = 0.000005815 V 01:39:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421406 Vs 01:39:47 Integrated Voltage Measurement... 01:40:06 Voltage Offset Correction: v_off_ini = 0.000004622 V, v_off_fin = -0.000002638 V 01:40:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305019 Vs 01:40:09 Temperature Measurement, Probe Number = 0, T = 20.264000 C 01:40:10 Temperature Measurement, Probe Number = 1, T = 20.007000 C 01:40:10 Temperature Measurement, Probe Number = 2, T = 19.976000 C 01:40:11 Temperature Measurement, Probe Number = 3, T = 19.966000 C 01:40:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.97 01:40:11 Integrated Voltage Measurement... 01:40:30 Voltage Offset Correction: v_off_ini = 0.000001145 V, v_off_fin = 0.000006144 V 01:40:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429221 Vs 01:40:31 Integrated Voltage Measurement... 01:40:50 Voltage Offset Correction: v_off_ini = 0.000005165 V, v_off_fin = -0.000001895 V 01:40:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310175 Vs 01:40:53 Temperature Measurement, Probe Number = 0, T = 20.270000 C 01:40:54 Temperature Measurement, Probe Number = 1, T = 20.009000 C 01:40:54 Temperature Measurement, Probe Number = 2, T = 19.977000 C 01:40:55 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:40:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:40:55 Integrated Voltage Measurement... 01:41:14 Voltage Offset Correction: v_off_ini = 0.000001804 V, v_off_fin = 0.000006015 V 01:41:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428183 Vs 01:41:15 Integrated Voltage Measurement... 01:41:34 Voltage Offset Correction: v_off_ini = 0.000005196 V, v_off_fin = -0.000002410 V 01:41:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307920 Vs 01:41:37 Temperature Measurement, Probe Number = 0, T = 20.261000 C 01:41:38 Temperature Measurement, Probe Number = 1, T = 20.005000 C 01:41:38 Temperature Measurement, Probe Number = 2, T = 19.976000 C 01:41:39 Temperature Measurement, Probe Number = 3, T = 19.965000 C 01:41:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 01:41:39 Integrated Voltage Measurement... 01:41:58 Voltage Offset Correction: v_off_ini = 0.000000927 V, v_off_fin = 0.000005699 V 01:41:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425171 Vs 01:41:59 Integrated Voltage Measurement... 01:42:18 Voltage Offset Correction: v_off_ini = 0.000004660 V, v_off_fin = -0.000001959 V 01:42:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175305419 Vs 02:12:21 Temperature Measurement, Probe Number = 0, T = 20.258000 C 02:12:22 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:12:22 Temperature Measurement, Probe Number = 2, T = 19.968000 C 02:12:23 Temperature Measurement, Probe Number = 3, T = 19.959000 C 02:12:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:12:23 Integrated Voltage Measurement... 02:12:42 Voltage Offset Correction: v_off_ini = 0.000003450 V, v_off_fin = 0.000005929 V 02:12:42 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175513960 Vs 02:12:43 Integrated Voltage Measurement... 02:13:02 Voltage Offset Correction: v_off_ini = 0.000004805 V, v_off_fin = -0.000001968 V 02:13:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312149 Vs 02:13:05 Temperature Measurement, Probe Number = 0, T = 20.275000 C 02:13:06 Temperature Measurement, Probe Number = 1, T = 19.999000 C 02:13:06 Temperature Measurement, Probe Number = 2, T = 19.972000 C 02:13:07 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:13:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:13:07 Integrated Voltage Measurement... 02:13:26 Voltage Offset Correction: v_off_ini = 0.000001210 V, v_off_fin = 0.000006036 V 02:13:27 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175418165 Vs 02:13:27 Integrated Voltage Measurement... 02:13:46 Voltage Offset Correction: v_off_ini = 0.000004953 V, v_off_fin = -0.000001939 V 02:13:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302980 Vs 02:13:49 Temperature Measurement, Probe Number = 0, T = 20.236000 C 02:13:50 Temperature Measurement, Probe Number = 1, T = 20.001000 C 02:13:50 Temperature Measurement, Probe Number = 2, T = 19.972000 C 02:13:51 Temperature Measurement, Probe Number = 3, T = 19.962000 C 02:13:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:13:51 Integrated Voltage Measurement... 02:14:10 Voltage Offset Correction: v_off_ini = 0.000001229 V, v_off_fin = 0.000005467 V 02:14:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423739 Vs 02:14:11 Integrated Voltage Measurement... 02:14:30 Voltage Offset Correction: v_off_ini = 0.000004557 V, v_off_fin = -0.000002104 V 02:14:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307342 Vs 02:14:33 Temperature Measurement, Probe Number = 0, T = 20.259000 C 02:14:34 Temperature Measurement, Probe Number = 1, T = 20.005000 C 02:14:34 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:14:35 Temperature Measurement, Probe Number = 3, T = 19.964000 C 02:14:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:14:35 Integrated Voltage Measurement... 02:14:54 Voltage Offset Correction: v_off_ini = 0.000001268 V, v_off_fin = 0.000005478 V 02:14:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420527 Vs 02:14:55 Integrated Voltage Measurement... 02:15:14 Voltage Offset Correction: v_off_ini = 0.000004654 V, v_off_fin = -0.000002749 V 02:15:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175311940 Vs 02:15:17 Temperature Measurement, Probe Number = 0, T = 20.278000 C 02:15:18 Temperature Measurement, Probe Number = 1, T = 20.003000 C 02:15:18 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:15:19 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:15:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:15:19 Integrated Voltage Measurement... 02:15:38 Voltage Offset Correction: v_off_ini = 0.000000998 V, v_off_fin = 0.000006037 V 02:15:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430145 Vs 02:15:39 Integrated Voltage Measurement... 02:15:58 Voltage Offset Correction: v_off_ini = 0.000005145 V, v_off_fin = -0.000002805 V 02:15:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306261 Vs 02:16:01 Temperature Measurement, Probe Number = 0, T = 20.260000 C 02:16:01 Temperature Measurement, Probe Number = 1, T = 20.005000 C 02:16:02 Temperature Measurement, Probe Number = 2, T = 19.976000 C 02:16:03 Temperature Measurement, Probe Number = 3, T = 19.964000 C 02:16:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:16:03 Integrated Voltage Measurement... 02:16:22 Voltage Offset Correction: v_off_ini = 0.000000793 V, v_off_fin = 0.000004961 V 02:16:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423840 Vs 02:16:23 Integrated Voltage Measurement... 02:16:42 Voltage Offset Correction: v_off_ini = 0.000004565 V, v_off_fin = -0.000002739 V 02:16:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306387 Vs 02:16:44 Temperature Measurement, Probe Number = 0, T = 20.262000 C 02:16:45 Temperature Measurement, Probe Number = 1, T = 20.004000 C 02:16:46 Temperature Measurement, Probe Number = 2, T = 19.974000 C 02:16:46 Temperature Measurement, Probe Number = 3, T = 19.965000 C 02:16:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:16:47 Integrated Voltage Measurement... 02:17:06 Voltage Offset Correction: v_off_ini = 0.000001084 V, v_off_fin = 0.000005700 V 02:17:06 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426563 Vs 02:17:06 Integrated Voltage Measurement... 02:17:26 Voltage Offset Correction: v_off_ini = 0.000004773 V, v_off_fin = -0.000002292 V 02:17:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175315146 Vs 02:17:28 Temperature Measurement, Probe Number = 0, T = 20.269000 C 02:17:29 Temperature Measurement, Probe Number = 1, T = 20.004000 C 02:17:30 Temperature Measurement, Probe Number = 2, T = 19.975000 C 02:17:30 Temperature Measurement, Probe Number = 3, T = 19.963000 C 02:17:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 02:17:31 Integrated Voltage Measurement... 02:17:50 Voltage Offset Correction: v_off_ini = 0.000000814 V, v_off_fin = 0.000005370 V 02:17:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422039 Vs 02:17:50 Integrated Voltage Measurement... 02:18:09 Voltage Offset Correction: v_off_ini = 0.000004644 V, v_off_fin = -0.000002930 V 02:18:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313413 Vs 02:18:12 Temperature Measurement, Probe Number = 0, T = 20.235000 C 02:18:13 Temperature Measurement, Probe Number = 1, T = 20.002000 C 02:18:14 Temperature Measurement, Probe Number = 2, T = 19.970000 C 02:18:14 Temperature Measurement, Probe Number = 3, T = 19.964000 C 02:18:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:18:14 Integrated Voltage Measurement... 02:18:34 Voltage Offset Correction: v_off_ini = 0.000000612 V, v_off_fin = 0.000005213 V 02:18:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421095 Vs 02:18:34 Integrated Voltage Measurement... 02:18:54 Voltage Offset Correction: v_off_ini = 0.000003976 V, v_off_fin = -0.000002379 V 02:18:54 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175322162 Vs 02:18:56 Temperature Measurement, Probe Number = 0, T = 20.245000 C 02:18:57 Temperature Measurement, Probe Number = 1, T = 20.005000 C 02:18:58 Temperature Measurement, Probe Number = 2, T = 19.973000 C 02:18:58 Temperature Measurement, Probe Number = 3, T = 19.966000 C 02:18:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.97 02:18:59 Integrated Voltage Measurement... 02:19:18 Voltage Offset Correction: v_off_ini = 0.000000461 V, v_off_fin = 0.000004851 V 02:19:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175420296 Vs 02:19:18 Integrated Voltage Measurement... 02:19:38 Voltage Offset Correction: v_off_ini = 0.000004325 V, v_off_fin = -0.000002326 V 02:19:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175323232 Vs 02:49:40 Temperature Measurement, Probe Number = 0, T = 20.209000 C 02:49:41 Temperature Measurement, Probe Number = 1, T = 19.994000 C 02:49:42 Temperature Measurement, Probe Number = 2, T = 19.966000 C 02:49:43 Temperature Measurement, Probe Number = 3, T = 19.957000 C 02:49:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:49:43 Integrated Voltage Measurement... 02:50:02 Voltage Offset Correction: v_off_ini = 0.000003741 V, v_off_fin = 0.000006010 V 02:50:03 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175523300 Vs 02:50:03 Integrated Voltage Measurement... 02:50:22 Voltage Offset Correction: v_off_ini = 0.000005237 V, v_off_fin = -0.000002893 V 02:50:22 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175302985 Vs 02:50:25 Temperature Measurement, Probe Number = 0, T = 20.204000 C 02:50:25 Temperature Measurement, Probe Number = 1, T = 19.995000 C 02:50:26 Temperature Measurement, Probe Number = 2, T = 19.969000 C 02:50:27 Temperature Measurement, Probe Number = 3, T = 19.956000 C 02:50:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:50:27 Integrated Voltage Measurement... 02:50:46 Voltage Offset Correction: v_off_ini = 0.000000503 V, v_off_fin = 0.000005227 V 02:50:46 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429172 Vs 02:50:46 Integrated Voltage Measurement... 02:51:05 Voltage Offset Correction: v_off_ini = 0.000004532 V, v_off_fin = -0.000002088 V 02:51:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306089 Vs 02:51:08 Temperature Measurement, Probe Number = 0, T = 20.203000 C 02:51:09 Temperature Measurement, Probe Number = 1, T = 19.996000 C 02:51:10 Temperature Measurement, Probe Number = 2, T = 19.967000 C 02:51:10 Temperature Measurement, Probe Number = 3, T = 19.958000 C 02:51:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:51:10 Integrated Voltage Measurement... 02:51:30 Voltage Offset Correction: v_off_ini = 0.000001376 V, v_off_fin = 0.000005677 V 02:51:30 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175433570 Vs 02:51:31 Integrated Voltage Measurement... 02:51:50 Voltage Offset Correction: v_off_ini = 0.000004911 V, v_off_fin = -0.000002483 V 02:51:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307062 Vs 02:51:53 Temperature Measurement, Probe Number = 0, T = 20.190000 C 02:51:53 Temperature Measurement, Probe Number = 1, T = 19.996000 C 02:51:54 Temperature Measurement, Probe Number = 2, T = 19.965000 C 02:51:55 Temperature Measurement, Probe Number = 3, T = 19.956000 C 02:51:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.96 02:51:55 Integrated Voltage Measurement... 02:52:14 Voltage Offset Correction: v_off_ini = 0.000001014 V, v_off_fin = 0.000005728 V 02:52:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424881 Vs 02:52:14 Integrated Voltage Measurement... 02:52:34 Voltage Offset Correction: v_off_ini = 0.000004662 V, v_off_fin = -0.000002588 V 02:52:34 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306392 Vs 02:52:37 Temperature Measurement, Probe Number = 0, T = 20.224000 C 02:52:37 Temperature Measurement, Probe Number = 1, T = 19.995000 C 02:52:38 Temperature Measurement, Probe Number = 2, T = 19.967000 C 02:52:39 Temperature Measurement, Probe Number = 3, T = 19.956000 C 02:52:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:52:39 Integrated Voltage Measurement... 02:52:58 Voltage Offset Correction: v_off_ini = 0.000000798 V, v_off_fin = 0.000005424 V 02:52:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419971 Vs 02:52:59 Integrated Voltage Measurement... 02:53:18 Voltage Offset Correction: v_off_ini = 0.000004722 V, v_off_fin = -0.000001492 V 02:53:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175303800 Vs 02:53:21 Temperature Measurement, Probe Number = 0, T = 20.249000 C 02:53:22 Temperature Measurement, Probe Number = 1, T = 19.995000 C 02:53:23 Temperature Measurement, Probe Number = 2, T = 19.964000 C 02:53:23 Temperature Measurement, Probe Number = 3, T = 19.959000 C 02:53:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.96 02:53:23 Integrated Voltage Measurement... 02:53:43 Voltage Offset Correction: v_off_ini = 0.000001530 V, v_off_fin = 0.000005714 V 02:53:43 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175419000 Vs 02:53:43 Integrated Voltage Measurement... 02:54:02 Voltage Offset Correction: v_off_ini = 0.000004736 V, v_off_fin = -0.000002885 V 02:54:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304542 Vs 02:54:05 Temperature Measurement, Probe Number = 0, T = 20.243000 C 02:54:05 Temperature Measurement, Probe Number = 1, T = 19.996000 C 02:54:06 Temperature Measurement, Probe Number = 2, T = 19.965000 C 02:54:07 Temperature Measurement, Probe Number = 3, T = 19.956000 C 02:54:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.96 02:54:07 Integrated Voltage Measurement... 02:54:26 Voltage Offset Correction: v_off_ini = 0.000001058 V, v_off_fin = 0.000005184 V 02:54:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175426329 Vs 02:54:26 Integrated Voltage Measurement... 02:54:46 Voltage Offset Correction: v_off_ini = 0.000005027 V, v_off_fin = -0.000002762 V 02:54:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175317107 Vs 02:54:49 Temperature Measurement, Probe Number = 0, T = 20.252000 C 02:54:49 Temperature Measurement, Probe Number = 1, T = 19.998000 C 02:54:50 Temperature Measurement, Probe Number = 2, T = 19.970000 C 02:54:51 Temperature Measurement, Probe Number = 3, T = 19.961000 C 02:54:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:54:51 Integrated Voltage Measurement... 02:55:10 Voltage Offset Correction: v_off_ini = 0.000000863 V, v_off_fin = 0.000005585 V 02:55:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426234 Vs 02:55:10 Integrated Voltage Measurement... 02:55:29 Voltage Offset Correction: v_off_ini = 0.000004689 V, v_off_fin = -0.000002948 V 02:55:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312035 Vs 02:55:32 Temperature Measurement, Probe Number = 0, T = 20.252000 C 02:55:33 Temperature Measurement, Probe Number = 1, T = 19.995000 C 02:55:33 Temperature Measurement, Probe Number = 2, T = 19.969000 C 02:55:34 Temperature Measurement, Probe Number = 3, T = 19.956000 C 02:55:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:55:34 Integrated Voltage Measurement... 02:55:53 Voltage Offset Correction: v_off_ini = 0.000000691 V, v_off_fin = 0.000005815 V 02:55:53 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175434536 Vs 02:55:53 Integrated Voltage Measurement... 02:56:12 Voltage Offset Correction: v_off_ini = 0.000004972 V, v_off_fin = -0.000002183 V 02:56:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175307115 Vs 02:56:15 Temperature Measurement, Probe Number = 0, T = 20.265000 C 02:56:16 Temperature Measurement, Probe Number = 1, T = 19.995000 C 02:56:17 Temperature Measurement, Probe Number = 2, T = 19.969000 C 02:56:17 Temperature Measurement, Probe Number = 3, T = 19.958000 C 02:56:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 02:56:17 Integrated Voltage Measurement... 02:56:37 Voltage Offset Correction: v_off_ini = 0.000000939 V, v_off_fin = 0.000005340 V 02:56:37 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432076 Vs 02:56:38 Integrated Voltage Measurement... 02:56:57 Voltage Offset Correction: v_off_ini = 0.000004488 V, v_off_fin = -0.000003087 V 02:56:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175311847 Vs 03:27:00 Temperature Measurement, Probe Number = 0, T = 20.214000 C 03:27:01 Temperature Measurement, Probe Number = 1, T = 19.995000 C 03:27:01 Temperature Measurement, Probe Number = 2, T = 19.967000 C 03:27:02 Temperature Measurement, Probe Number = 3, T = 19.956000 C 03:27:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:27:02 Integrated Voltage Measurement... 03:27:21 Voltage Offset Correction: v_off_ini = 0.000003811 V, v_off_fin = 0.000005589 V 03:27:21 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175515807 Vs 03:27:21 Integrated Voltage Measurement... 03:27:41 Voltage Offset Correction: v_off_ini = 0.000004939 V, v_off_fin = -0.000002545 V 03:27:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310592 Vs 03:27:44 Temperature Measurement, Probe Number = 0, T = 20.223000 C 03:27:44 Temperature Measurement, Probe Number = 1, T = 19.993000 C 03:27:45 Temperature Measurement, Probe Number = 2, T = 19.965000 C 03:27:46 Temperature Measurement, Probe Number = 3, T = 19.950000 C 03:27:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:27:46 Integrated Voltage Measurement... 03:28:05 Voltage Offset Correction: v_off_ini = 0.000001046 V, v_off_fin = 0.000005605 V 03:28:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423286 Vs 03:28:05 Integrated Voltage Measurement... 03:28:24 Voltage Offset Correction: v_off_ini = 0.000005075 V, v_off_fin = -0.000002863 V 03:28:24 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302131 Vs 03:28:27 Temperature Measurement, Probe Number = 0, T = 20.240000 C 03:28:28 Temperature Measurement, Probe Number = 1, T = 19.991000 C 03:28:28 Temperature Measurement, Probe Number = 2, T = 19.966000 C 03:28:29 Temperature Measurement, Probe Number = 3, T = 19.956000 C 03:28:29 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 03:28:29 Integrated Voltage Measurement... 03:28:48 Voltage Offset Correction: v_off_ini = 0.000001221 V, v_off_fin = 0.000005643 V 03:28:48 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423282 Vs 03:28:49 Integrated Voltage Measurement... 03:29:08 Voltage Offset Correction: v_off_ini = 0.000004704 V, v_off_fin = -0.000002270 V 03:29:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312497 Vs 03:29:11 Temperature Measurement, Probe Number = 0, T = 20.235000 C 03:29:12 Temperature Measurement, Probe Number = 1, T = 19.995000 C 03:29:12 Temperature Measurement, Probe Number = 2, T = 19.967000 C 03:29:13 Temperature Measurement, Probe Number = 3, T = 19.955000 C 03:29:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 03:29:13 Integrated Voltage Measurement... 03:29:33 Voltage Offset Correction: v_off_ini = 0.000001157 V, v_off_fin = 0.000005408 V 03:29:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175423507 Vs 03:29:33 Integrated Voltage Measurement... 03:29:52 Voltage Offset Correction: v_off_ini = 0.000004691 V, v_off_fin = -0.000002593 V 03:29:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175304484 Vs 03:29:55 Temperature Measurement, Probe Number = 0, T = 20.248000 C 03:29:56 Temperature Measurement, Probe Number = 1, T = 19.996000 C 03:29:56 Temperature Measurement, Probe Number = 2, T = 19.967000 C 03:29:57 Temperature Measurement, Probe Number = 3, T = 19.954000 C 03:29:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 03:29:57 Integrated Voltage Measurement... 03:30:16 Voltage Offset Correction: v_off_ini = 0.000000882 V, v_off_fin = 0.000005947 V 03:30:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429254 Vs 03:30:17 Integrated Voltage Measurement... 03:30:36 Voltage Offset Correction: v_off_ini = 0.000004807 V, v_off_fin = -0.000002298 V 03:30:36 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309311 Vs 03:30:39 Temperature Measurement, Probe Number = 0, T = 20.252000 C 03:30:40 Temperature Measurement, Probe Number = 1, T = 19.994000 C 03:30:40 Temperature Measurement, Probe Number = 2, T = 19.965000 C 03:30:41 Temperature Measurement, Probe Number = 3, T = 19.955000 C 03:30:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:30:41 Integrated Voltage Measurement... 03:31:00 Voltage Offset Correction: v_off_ini = 0.000001540 V, v_off_fin = 0.000005871 V 03:31:01 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175433183 Vs 03:31:01 Integrated Voltage Measurement... 03:31:20 Voltage Offset Correction: v_off_ini = 0.000005036 V, v_off_fin = -0.000002384 V 03:31:20 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175312248 Vs 03:31:23 Temperature Measurement, Probe Number = 0, T = 20.255000 C 03:31:24 Temperature Measurement, Probe Number = 1, T = 19.996000 C 03:31:24 Temperature Measurement, Probe Number = 2, T = 19.963000 C 03:31:25 Temperature Measurement, Probe Number = 3, T = 19.954000 C 03:31:25 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:31:25 Integrated Voltage Measurement... 03:31:44 Voltage Offset Correction: v_off_ini = 0.000000848 V, v_off_fin = 0.000005565 V 03:31:44 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422652 Vs 03:31:45 Integrated Voltage Measurement... 03:32:04 Voltage Offset Correction: v_off_ini = 0.000004574 V, v_off_fin = -0.000002701 V 03:32:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305890 Vs 03:32:06 Temperature Measurement, Probe Number = 0, T = 20.245000 C 03:32:07 Temperature Measurement, Probe Number = 1, T = 19.994000 C 03:32:08 Temperature Measurement, Probe Number = 2, T = 19.961000 C 03:32:08 Temperature Measurement, Probe Number = 3, T = 19.955000 C 03:32:08 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:32:09 Integrated Voltage Measurement... 03:32:28 Voltage Offset Correction: v_off_ini = 0.000001275 V, v_off_fin = 0.000005532 V 03:32:28 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424986 Vs 03:32:28 Integrated Voltage Measurement... 03:32:48 Voltage Offset Correction: v_off_ini = 0.000004632 V, v_off_fin = -0.000002594 V 03:32:48 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308433 Vs 03:32:50 Temperature Measurement, Probe Number = 0, T = 20.279000 C 03:32:51 Temperature Measurement, Probe Number = 1, T = 19.994000 C 03:32:52 Temperature Measurement, Probe Number = 2, T = 19.962000 C 03:32:52 Temperature Measurement, Probe Number = 3, T = 19.954000 C 03:32:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:32:53 Integrated Voltage Measurement... 03:33:12 Voltage Offset Correction: v_off_ini = 0.000001122 V, v_off_fin = 0.000005421 V 03:33:12 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428261 Vs 03:33:12 Integrated Voltage Measurement... 03:33:31 Voltage Offset Correction: v_off_ini = 0.000004729 V, v_off_fin = -0.000002460 V 03:33:32 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312147 Vs 03:33:34 Temperature Measurement, Probe Number = 0, T = 20.234000 C 03:33:35 Temperature Measurement, Probe Number = 1, T = 19.990000 C 03:33:36 Temperature Measurement, Probe Number = 2, T = 19.963000 C 03:33:36 Temperature Measurement, Probe Number = 3, T = 19.952000 C 03:33:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 03:33:36 Integrated Voltage Measurement... 03:33:56 Voltage Offset Correction: v_off_ini = 0.000001536 V, v_off_fin = 0.000004854 V 03:33:56 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175422507 Vs 03:33:56 Integrated Voltage Measurement... 03:34:16 Voltage Offset Correction: v_off_ini = 0.000004134 V, v_off_fin = -0.000002282 V 03:34:16 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175312348 Vs 04:04:19 Temperature Measurement, Probe Number = 0, T = 20.194000 C 04:04:19 Temperature Measurement, Probe Number = 1, T = 19.989000 C 04:04:20 Temperature Measurement, Probe Number = 2, T = 19.957000 C 04:04:21 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:04:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:04:21 Integrated Voltage Measurement... 04:04:40 Voltage Offset Correction: v_off_ini = 0.000003597 V, v_off_fin = 0.000005967 V 04:04:40 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175510797 Vs 04:04:40 Integrated Voltage Measurement... 04:05:00 Voltage Offset Correction: v_off_ini = 0.000005147 V, v_off_fin = -0.000002293 V 04:05:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301940 Vs 04:05:02 Temperature Measurement, Probe Number = 0, T = 20.203000 C 04:05:03 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:05:04 Temperature Measurement, Probe Number = 2, T = 19.954000 C 04:05:04 Temperature Measurement, Probe Number = 3, T = 19.947000 C 04:05:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:05:05 Integrated Voltage Measurement... 04:05:24 Voltage Offset Correction: v_off_ini = 0.000001351 V, v_off_fin = 0.000005356 V 04:05:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423711 Vs 04:05:24 Integrated Voltage Measurement... 04:05:43 Voltage Offset Correction: v_off_ini = 0.000004756 V, v_off_fin = -0.000002210 V 04:05:43 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175312218 Vs 04:05:46 Temperature Measurement, Probe Number = 0, T = 20.176000 C 04:05:47 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:05:47 Temperature Measurement, Probe Number = 2, T = 19.955000 C 04:05:48 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:05:48 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 04:05:48 Integrated Voltage Measurement... 04:06:08 Voltage Offset Correction: v_off_ini = 0.000001373 V, v_off_fin = 0.000005399 V 04:06:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426651 Vs 04:06:08 Integrated Voltage Measurement... 04:06:27 Voltage Offset Correction: v_off_ini = 0.000004948 V, v_off_fin = -0.000001966 V 04:06:27 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301950 Vs 04:06:30 Temperature Measurement, Probe Number = 0, T = 20.165000 C 04:06:30 Temperature Measurement, Probe Number = 1, T = 19.990000 C 04:06:31 Temperature Measurement, Probe Number = 2, T = 19.961000 C 04:06:32 Temperature Measurement, Probe Number = 3, T = 19.950000 C 04:06:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:06:32 Integrated Voltage Measurement... 04:06:52 Voltage Offset Correction: v_off_ini = 0.000000960 V, v_off_fin = 0.000005037 V 04:06:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175429477 Vs 04:06:52 Integrated Voltage Measurement... 04:07:12 Voltage Offset Correction: v_off_ini = 0.000004696 V, v_off_fin = -0.000002383 V 04:07:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175313665 Vs 04:07:14 Temperature Measurement, Probe Number = 0, T = 20.174000 C 04:07:15 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:07:16 Temperature Measurement, Probe Number = 2, T = 19.960000 C 04:07:16 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:07:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:07:17 Integrated Voltage Measurement... 04:07:36 Voltage Offset Correction: v_off_ini = 0.000001659 V, v_off_fin = 0.000005443 V 04:07:36 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175425221 Vs 04:07:37 Integrated Voltage Measurement... 04:07:56 Voltage Offset Correction: v_off_ini = 0.000004669 V, v_off_fin = -0.000002247 V 04:07:56 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175309515 Vs 04:07:59 Temperature Measurement, Probe Number = 0, T = 20.225000 C 04:07:59 Temperature Measurement, Probe Number = 1, T = 19.990000 C 04:08:00 Temperature Measurement, Probe Number = 2, T = 19.962000 C 04:08:00 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:08:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:08:01 Integrated Voltage Measurement... 04:08:20 Voltage Offset Correction: v_off_ini = 0.000000896 V, v_off_fin = 0.000005148 V 04:08:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425822 Vs 04:08:20 Integrated Voltage Measurement... 04:08:40 Voltage Offset Correction: v_off_ini = 0.000004534 V, v_off_fin = -0.000001722 V 04:08:40 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175313946 Vs 04:08:43 Temperature Measurement, Probe Number = 0, T = 20.251000 C 04:08:43 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:08:44 Temperature Measurement, Probe Number = 2, T = 19.960000 C 04:08:45 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:08:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:08:45 Integrated Voltage Measurement... 04:09:04 Voltage Offset Correction: v_off_ini = 0.000001306 V, v_off_fin = 0.000005369 V 04:09:04 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175417106 Vs 04:09:04 Integrated Voltage Measurement... 04:09:24 Voltage Offset Correction: v_off_ini = 0.000004683 V, v_off_fin = -0.000002674 V 04:09:24 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175319231 Vs 04:09:26 Temperature Measurement, Probe Number = 0, T = 20.245000 C 04:09:27 Temperature Measurement, Probe Number = 1, T = 19.991000 C 04:09:28 Temperature Measurement, Probe Number = 2, T = 19.961000 C 04:09:28 Temperature Measurement, Probe Number = 3, T = 19.949000 C 04:09:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:09:29 Integrated Voltage Measurement... 04:09:48 Voltage Offset Correction: v_off_ini = 0.000000865 V, v_off_fin = 0.000005627 V 04:09:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429581 Vs 04:09:49 Integrated Voltage Measurement... 04:10:08 Voltage Offset Correction: v_off_ini = 0.000004834 V, v_off_fin = -0.000002824 V 04:10:08 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309453 Vs 04:10:11 Temperature Measurement, Probe Number = 0, T = 20.245000 C 04:10:11 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:10:12 Temperature Measurement, Probe Number = 2, T = 19.962000 C 04:10:13 Temperature Measurement, Probe Number = 3, T = 19.950000 C 04:10:13 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:10:13 Integrated Voltage Measurement... 04:10:32 Voltage Offset Correction: v_off_ini = 0.000001726 V, v_off_fin = 0.000005873 V 04:10:32 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175440537 Vs 04:10:32 Integrated Voltage Measurement... 04:10:52 Voltage Offset Correction: v_off_ini = 0.000005308 V, v_off_fin = -0.000003147 V 04:10:52 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175308506 Vs 04:10:54 Temperature Measurement, Probe Number = 0, T = 20.229000 C 04:10:55 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:10:56 Temperature Measurement, Probe Number = 2, T = 19.960000 C 04:10:56 Temperature Measurement, Probe Number = 3, T = 19.951000 C 04:10:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:10:57 Integrated Voltage Measurement... 04:11:16 Voltage Offset Correction: v_off_ini = 0.000002010 V, v_off_fin = 0.000006329 V 04:11:16 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175438889 Vs 04:11:16 Integrated Voltage Measurement... 04:11:36 Voltage Offset Correction: v_off_ini = 0.000005501 V, v_off_fin = -0.000002073 V 04:11:36 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175315385 Vs 04:41:39 Temperature Measurement, Probe Number = 0, T = 20.311000 C 04:41:39 Temperature Measurement, Probe Number = 1, T = 19.993000 C 04:41:40 Temperature Measurement, Probe Number = 2, T = 19.964000 C 04:41:41 Temperature Measurement, Probe Number = 3, T = 19.952000 C 04:41:41 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:41:41 Integrated Voltage Measurement... 04:42:01 Voltage Offset Correction: v_off_ini = 0.000003600 V, v_off_fin = 0.000005735 V 04:42:01 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175529764 Vs 04:42:01 Integrated Voltage Measurement... 04:42:21 Voltage Offset Correction: v_off_ini = 0.000004894 V, v_off_fin = -0.000002698 V 04:42:21 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175302704 Vs 04:42:23 Temperature Measurement, Probe Number = 0, T = 20.304000 C 04:42:24 Temperature Measurement, Probe Number = 1, T = 19.991000 C 04:42:25 Temperature Measurement, Probe Number = 2, T = 19.965000 C 04:42:25 Temperature Measurement, Probe Number = 3, T = 19.950000 C 04:42:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:42:26 Integrated Voltage Measurement... 04:42:45 Voltage Offset Correction: v_off_ini = 0.000000385 V, v_off_fin = 0.000005810 V 04:42:45 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412884 Vs 04:42:45 Integrated Voltage Measurement... 04:43:04 Voltage Offset Correction: v_off_ini = 0.000004999 V, v_off_fin = -0.000002518 V 04:43:04 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293577 Vs 04:43:07 Temperature Measurement, Probe Number = 0, T = 20.312000 C 04:43:08 Temperature Measurement, Probe Number = 1, T = 19.990000 C 04:43:08 Temperature Measurement, Probe Number = 2, T = 19.965000 C 04:43:09 Temperature Measurement, Probe Number = 3, T = 19.953000 C 04:43:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:43:09 Integrated Voltage Measurement... 04:43:29 Voltage Offset Correction: v_off_ini = 0.000001739 V, v_off_fin = 0.000005569 V 04:43:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175423606 Vs 04:43:29 Integrated Voltage Measurement... 04:43:48 Voltage Offset Correction: v_off_ini = 0.000004726 V, v_off_fin = -0.000002598 V 04:43:48 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175291553 Vs 04:43:51 Temperature Measurement, Probe Number = 0, T = 20.279000 C 04:43:52 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:43:52 Temperature Measurement, Probe Number = 2, T = 19.967000 C 04:43:53 Temperature Measurement, Probe Number = 3, T = 19.953000 C 04:43:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 04:43:53 Integrated Voltage Measurement... 04:44:12 Voltage Offset Correction: v_off_ini = 0.000001445 V, v_off_fin = 0.000005601 V 04:44:12 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175421887 Vs 04:44:13 Integrated Voltage Measurement... 04:44:32 Voltage Offset Correction: v_off_ini = 0.000004781 V, v_off_fin = -0.000001678 V 04:44:32 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175300867 Vs 04:44:35 Temperature Measurement, Probe Number = 0, T = 20.279000 C 04:44:36 Temperature Measurement, Probe Number = 1, T = 19.990000 C 04:44:36 Temperature Measurement, Probe Number = 2, T = 19.964000 C 04:44:37 Temperature Measurement, Probe Number = 3, T = 19.952000 C 04:44:37 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:44:37 Integrated Voltage Measurement... 04:44:56 Voltage Offset Correction: v_off_ini = 0.000001466 V, v_off_fin = 0.000005733 V 04:44:56 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415725 Vs 04:44:57 Integrated Voltage Measurement... 04:45:16 Voltage Offset Correction: v_off_ini = 0.000005036 V, v_off_fin = -0.000002957 V 04:45:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299032 Vs 04:45:19 Temperature Measurement, Probe Number = 0, T = 20.285000 C 04:45:19 Temperature Measurement, Probe Number = 1, T = 19.987000 C 04:45:20 Temperature Measurement, Probe Number = 2, T = 19.963000 C 04:45:21 Temperature Measurement, Probe Number = 3, T = 19.953000 C 04:45:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:45:21 Integrated Voltage Measurement... 04:45:40 Voltage Offset Correction: v_off_ini = 0.000001695 V, v_off_fin = 0.000005390 V 04:45:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413261 Vs 04:45:41 Integrated Voltage Measurement... 04:46:00 Voltage Offset Correction: v_off_ini = 0.000004274 V, v_off_fin = -0.000002742 V 04:46:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303853 Vs 04:46:03 Temperature Measurement, Probe Number = 0, T = 20.316000 C 04:46:04 Temperature Measurement, Probe Number = 1, T = 19.992000 C 04:46:04 Temperature Measurement, Probe Number = 2, T = 19.966000 C 04:46:05 Temperature Measurement, Probe Number = 3, T = 19.959000 C 04:46:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 04:46:05 Integrated Voltage Measurement... 04:46:24 Voltage Offset Correction: v_off_ini = 0.000000839 V, v_off_fin = 0.000005338 V 04:46:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406936 Vs 04:46:25 Integrated Voltage Measurement... 04:46:44 Voltage Offset Correction: v_off_ini = 0.000004669 V, v_off_fin = -0.000002838 V 04:46:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302150 Vs 04:46:47 Temperature Measurement, Probe Number = 0, T = 20.287000 C 04:46:48 Temperature Measurement, Probe Number = 1, T = 19.994000 C 04:46:48 Temperature Measurement, Probe Number = 2, T = 19.967000 C 04:46:49 Temperature Measurement, Probe Number = 3, T = 19.960000 C 04:46:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 04:46:49 Integrated Voltage Measurement... 04:47:08 Voltage Offset Correction: v_off_ini = 0.000001598 V, v_off_fin = 0.000005335 V 04:47:09 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415073 Vs 04:47:09 Integrated Voltage Measurement... 04:47:28 Voltage Offset Correction: v_off_ini = 0.000004883 V, v_off_fin = -0.000002865 V 04:47:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291478 Vs 04:47:31 Temperature Measurement, Probe Number = 0, T = 20.239000 C 04:47:31 Temperature Measurement, Probe Number = 1, T = 19.990000 C 04:47:32 Temperature Measurement, Probe Number = 2, T = 19.964000 C 04:47:32 Temperature Measurement, Probe Number = 3, T = 19.954000 C 04:47:33 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:47:33 Integrated Voltage Measurement... 04:47:52 Voltage Offset Correction: v_off_ini = 0.000000709 V, v_off_fin = 0.000005327 V 04:47:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412711 Vs 04:47:53 Integrated Voltage Measurement... 04:48:12 Voltage Offset Correction: v_off_ini = 0.000004841 V, v_off_fin = -0.000002760 V 04:48:12 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175291567 Vs 04:48:14 Temperature Measurement, Probe Number = 0, T = 20.259000 C 04:48:15 Temperature Measurement, Probe Number = 1, T = 19.991000 C 04:48:16 Temperature Measurement, Probe Number = 2, T = 19.964000 C 04:48:16 Temperature Measurement, Probe Number = 3, T = 19.955000 C 04:48:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 04:48:17 Integrated Voltage Measurement... 04:48:36 Voltage Offset Correction: v_off_ini = 0.000000735 V, v_off_fin = 0.000005345 V 04:48:36 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175409019 Vs 04:48:36 Integrated Voltage Measurement... 04:48:55 Voltage Offset Correction: v_off_ini = 0.000004885 V, v_off_fin = -0.000001958 V 04:48:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305312 Vs 05:18:58 Temperature Measurement, Probe Number = 0, T = 20.101000 C 05:18:59 Temperature Measurement, Probe Number = 1, T = 19.985000 C 05:18:59 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:19:00 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:19:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:19:00 Integrated Voltage Measurement... 05:19:19 Voltage Offset Correction: v_off_ini = 0.000003618 V, v_off_fin = 0.000005545 V 05:19:20 Integrated Voltage Measurement Delta Gap = 0.0040030 m VT = 0.175497819 Vs 05:19:20 Integrated Voltage Measurement... 05:19:39 Voltage Offset Correction: v_off_ini = 0.000004740 V, v_off_fin = -0.000001518 V 05:19:39 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301392 Vs 05:19:42 Temperature Measurement, Probe Number = 0, T = 20.180000 C 05:19:43 Temperature Measurement, Probe Number = 1, T = 19.988000 C 05:19:43 Temperature Measurement, Probe Number = 2, T = 19.958000 C 05:19:44 Temperature Measurement, Probe Number = 3, T = 19.948000 C 05:19:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:19:44 Integrated Voltage Measurement... 05:20:03 Voltage Offset Correction: v_off_ini = 0.000001679 V, v_off_fin = 0.000005790 V 05:20:04 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419266 Vs 05:20:04 Integrated Voltage Measurement... 05:20:23 Voltage Offset Correction: v_off_ini = 0.000005303 V, v_off_fin = -0.000002129 V 05:20:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295571 Vs 05:20:25 Temperature Measurement, Probe Number = 0, T = 20.201000 C 05:20:26 Temperature Measurement, Probe Number = 1, T = 19.987000 C 05:20:27 Temperature Measurement, Probe Number = 2, T = 19.955000 C 05:20:27 Temperature Measurement, Probe Number = 3, T = 19.945000 C 05:20:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:20:28 Integrated Voltage Measurement... 05:20:47 Voltage Offset Correction: v_off_ini = 0.000001223 V, v_off_fin = 0.000005909 V 05:20:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175425557 Vs 05:20:47 Integrated Voltage Measurement... 05:21:06 Voltage Offset Correction: v_off_ini = 0.000005143 V, v_off_fin = -0.000003143 V 05:21:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303493 Vs 05:21:09 Temperature Measurement, Probe Number = 0, T = 20.210000 C 05:21:10 Temperature Measurement, Probe Number = 1, T = 19.988000 C 05:21:10 Temperature Measurement, Probe Number = 2, T = 19.958000 C 05:21:11 Temperature Measurement, Probe Number = 3, T = 19.947000 C 05:21:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:21:11 Integrated Voltage Measurement... 05:21:31 Voltage Offset Correction: v_off_ini = 0.000001114 V, v_off_fin = 0.000005136 V 05:21:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413311 Vs 05:21:32 Integrated Voltage Measurement... 05:21:51 Voltage Offset Correction: v_off_ini = 0.000004633 V, v_off_fin = -0.000002007 V 05:21:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297646 Vs 05:21:53 Temperature Measurement, Probe Number = 0, T = 20.167000 C 05:21:54 Temperature Measurement, Probe Number = 1, T = 19.990000 C 05:21:55 Temperature Measurement, Probe Number = 2, T = 19.959000 C 05:21:55 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:21:56 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:21:56 Integrated Voltage Measurement... 05:22:15 Voltage Offset Correction: v_off_ini = 0.000001354 V, v_off_fin = 0.000005693 V 05:22:15 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175417333 Vs 05:22:15 Integrated Voltage Measurement... 05:22:34 Voltage Offset Correction: v_off_ini = 0.000004688 V, v_off_fin = -0.000002827 V 05:22:34 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175299180 Vs 05:22:37 Temperature Measurement, Probe Number = 0, T = 20.197000 C 05:22:37 Temperature Measurement, Probe Number = 1, T = 19.988000 C 05:22:38 Temperature Measurement, Probe Number = 2, T = 19.959000 C 05:22:39 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:22:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:22:39 Integrated Voltage Measurement... 05:22:59 Voltage Offset Correction: v_off_ini = 0.000000886 V, v_off_fin = 0.000004925 V 05:22:59 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175419781 Vs 05:22:59 Integrated Voltage Measurement... 05:23:19 Voltage Offset Correction: v_off_ini = 0.000004647 V, v_off_fin = -0.000002248 V 05:23:19 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175306166 Vs 05:23:22 Temperature Measurement, Probe Number = 0, T = 20.215000 C 05:23:22 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:23:23 Temperature Measurement, Probe Number = 2, T = 19.959000 C 05:23:24 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:23:24 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:23:24 Integrated Voltage Measurement... 05:23:43 Voltage Offset Correction: v_off_ini = 0.000001622 V, v_off_fin = 0.000005359 V 05:23:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410427 Vs 05:23:43 Integrated Voltage Measurement... 05:24:03 Voltage Offset Correction: v_off_ini = 0.000004812 V, v_off_fin = -0.000002452 V 05:24:03 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300704 Vs 05:24:05 Temperature Measurement, Probe Number = 0, T = 20.252000 C 05:24:06 Temperature Measurement, Probe Number = 1, T = 19.985000 C 05:24:07 Temperature Measurement, Probe Number = 2, T = 19.957000 C 05:24:07 Temperature Measurement, Probe Number = 3, T = 19.946000 C 05:24:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 05:24:08 Integrated Voltage Measurement... 05:24:27 Voltage Offset Correction: v_off_ini = 0.000001293 V, v_off_fin = 0.000005787 V 05:24:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421679 Vs 05:24:27 Integrated Voltage Measurement... 05:24:47 Voltage Offset Correction: v_off_ini = 0.000004991 V, v_off_fin = -0.000001388 V 05:24:47 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302011 Vs 05:24:49 Temperature Measurement, Probe Number = 0, T = 20.213000 C 05:24:50 Temperature Measurement, Probe Number = 1, T = 19.984000 C 05:24:51 Temperature Measurement, Probe Number = 2, T = 19.953000 C 05:24:51 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:24:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:24:52 Integrated Voltage Measurement... 05:25:11 Voltage Offset Correction: v_off_ini = 0.000001371 V, v_off_fin = 0.000005943 V 05:25:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175424647 Vs 05:25:11 Integrated Voltage Measurement... 05:25:31 Voltage Offset Correction: v_off_ini = 0.000005186 V, v_off_fin = -0.000002420 V 05:25:31 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307405 Vs 05:25:34 Temperature Measurement, Probe Number = 0, T = 20.164000 C 05:25:34 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:25:35 Temperature Measurement, Probe Number = 2, T = 19.956000 C 05:25:36 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:25:36 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 05:25:36 Integrated Voltage Measurement... 05:25:55 Voltage Offset Correction: v_off_ini = 0.000001328 V, v_off_fin = 0.000005858 V 05:25:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175422685 Vs 05:25:55 Integrated Voltage Measurement... 05:26:15 Voltage Offset Correction: v_off_ini = 0.000004729 V, v_off_fin = -0.000002794 V 05:26:15 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305668 Vs 05:56:18 Temperature Measurement, Probe Number = 0, T = 20.176000 C 05:56:18 Temperature Measurement, Probe Number = 1, T = 19.980000 C 05:56:19 Temperature Measurement, Probe Number = 2, T = 19.952000 C 05:56:19 Temperature Measurement, Probe Number = 3, T = 19.942000 C 05:56:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.18 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:56:20 Integrated Voltage Measurement... 05:56:39 Voltage Offset Correction: v_off_ini = 0.000003545 V, v_off_fin = 0.000005743 V 05:56:39 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175504066 Vs 05:56:39 Integrated Voltage Measurement... 05:56:58 Voltage Offset Correction: v_off_ini = 0.000004981 V, v_off_fin = -0.000001995 V 05:56:58 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175301153 Vs 05:57:01 Temperature Measurement, Probe Number = 0, T = 20.149000 C 05:57:01 Temperature Measurement, Probe Number = 1, T = 19.981000 C 05:57:02 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:57:03 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:57:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.15 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:57:03 Integrated Voltage Measurement... 05:57:22 Voltage Offset Correction: v_off_ini = 0.000001094 V, v_off_fin = 0.000005694 V 05:57:22 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175423721 Vs 05:57:22 Integrated Voltage Measurement... 05:57:42 Voltage Offset Correction: v_off_ini = 0.000005110 V, v_off_fin = -0.000002625 V 05:57:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175313936 Vs 05:57:45 Temperature Measurement, Probe Number = 0, T = 20.130000 C 05:57:45 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:57:46 Temperature Measurement, Probe Number = 2, T = 19.957000 C 05:57:47 Temperature Measurement, Probe Number = 3, T = 19.943000 C 05:57:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 05:57:47 Integrated Voltage Measurement... 05:58:06 Voltage Offset Correction: v_off_ini = 0.000001147 V, v_off_fin = 0.000004870 V 05:58:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175419607 Vs 05:58:06 Integrated Voltage Measurement... 05:58:26 Voltage Offset Correction: v_off_ini = 0.000004224 V, v_off_fin = -0.000002557 V 05:58:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175310662 Vs 05:58:28 Temperature Measurement, Probe Number = 0, T = 20.126000 C 05:58:29 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:58:30 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:58:30 Temperature Measurement, Probe Number = 3, T = 19.944000 C 05:58:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:58:31 Integrated Voltage Measurement... 05:58:50 Voltage Offset Correction: v_off_ini = 0.000000498 V, v_off_fin = 0.000005226 V 05:58:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175421574 Vs 05:58:50 Integrated Voltage Measurement... 05:59:10 Voltage Offset Correction: v_off_ini = 0.000004683 V, v_off_fin = -0.000002924 V 05:59:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175316650 Vs 05:59:13 Temperature Measurement, Probe Number = 0, T = 20.127000 C 05:59:13 Temperature Measurement, Probe Number = 1, T = 19.986000 C 05:59:14 Temperature Measurement, Probe Number = 2, T = 19.954000 C 05:59:15 Temperature Measurement, Probe Number = 3, T = 19.947000 C 05:59:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.13 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.95 05:59:15 Integrated Voltage Measurement... 05:59:34 Voltage Offset Correction: v_off_ini = 0.000001017 V, v_off_fin = 0.000005864 V 05:59:34 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428570 Vs 05:59:34 Integrated Voltage Measurement... 05:59:53 Voltage Offset Correction: v_off_ini = 0.000004949 V, v_off_fin = -0.000002673 V 05:59:54 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175307606 Vs 05:59:56 Temperature Measurement, Probe Number = 0, T = 20.174000 C 05:59:57 Temperature Measurement, Probe Number = 1, T = 19.983000 C 05:59:58 Temperature Measurement, Probe Number = 2, T = 19.953000 C 05:59:58 Temperature Measurement, Probe Number = 3, T = 19.942000 C 05:59:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 05:59:58 Integrated Voltage Measurement... 06:00:18 Voltage Offset Correction: v_off_ini = 0.000001427 V, v_off_fin = 0.000005503 V 06:00:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175426589 Vs 06:00:18 Integrated Voltage Measurement... 06:00:38 Voltage Offset Correction: v_off_ini = 0.000004614 V, v_off_fin = -0.000002363 V 06:00:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303309 Vs 06:00:40 Temperature Measurement, Probe Number = 0, T = 20.217000 C 06:00:41 Temperature Measurement, Probe Number = 1, T = 19.984000 C 06:00:42 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:00:42 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:00:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:00:43 Integrated Voltage Measurement... 06:01:02 Voltage Offset Correction: v_off_ini = 0.000000925 V, v_off_fin = 0.000005318 V 06:01:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427783 Vs 06:01:03 Integrated Voltage Measurement... 06:01:22 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000002711 V 06:01:22 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175306567 Vs 06:01:25 Temperature Measurement, Probe Number = 0, T = 20.230000 C 06:01:26 Temperature Measurement, Probe Number = 1, T = 19.983000 C 06:01:26 Temperature Measurement, Probe Number = 2, T = 19.956000 C 06:01:27 Temperature Measurement, Probe Number = 3, T = 19.940000 C 06:01:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 06:01:27 Integrated Voltage Measurement... 06:01:46 Voltage Offset Correction: v_off_ini = 0.000001789 V, v_off_fin = 0.000005833 V 06:01:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429750 Vs 06:01:47 Integrated Voltage Measurement... 06:02:06 Voltage Offset Correction: v_off_ini = 0.000005398 V, v_off_fin = -0.000001388 V 06:02:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306775 Vs 06:02:09 Temperature Measurement, Probe Number = 0, T = 20.208000 C 06:02:10 Temperature Measurement, Probe Number = 1, T = 19.986000 C 06:02:11 Temperature Measurement, Probe Number = 2, T = 19.957000 C 06:02:11 Temperature Measurement, Probe Number = 3, T = 19.943000 C 06:02:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 06:02:11 Integrated Voltage Measurement... 06:02:30 Voltage Offset Correction: v_off_ini = 0.000001822 V, v_off_fin = 0.000005980 V 06:02:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425717 Vs 06:02:31 Integrated Voltage Measurement... 06:02:50 Voltage Offset Correction: v_off_ini = 0.000005293 V, v_off_fin = -0.000001900 V 06:02:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299034 Vs 06:02:53 Temperature Measurement, Probe Number = 0, T = 20.215000 C 06:02:54 Temperature Measurement, Probe Number = 1, T = 19.986000 C 06:02:54 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:02:55 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:02:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:02:55 Integrated Voltage Measurement... 06:03:14 Voltage Offset Correction: v_off_ini = 0.000001828 V, v_off_fin = 0.000006015 V 06:03:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175430103 Vs 06:03:15 Integrated Voltage Measurement... 06:03:34 Voltage Offset Correction: v_off_ini = 0.000005119 V, v_off_fin = -0.000002079 V 06:03:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302396 Vs 06:33:36 Temperature Measurement, Probe Number = 0, T = 20.159000 C 06:33:37 Temperature Measurement, Probe Number = 1, T = 19.976000 C 06:33:38 Temperature Measurement, Probe Number = 2, T = 19.945000 C 06:33:39 Temperature Measurement, Probe Number = 3, T = 19.935000 C 06:33:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.93 06:33:39 Integrated Voltage Measurement... 06:33:58 Voltage Offset Correction: v_off_ini = 0.000003786 V, v_off_fin = 0.000006469 V 06:33:58 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175528367 Vs 06:33:59 Integrated Voltage Measurement... 06:34:18 Voltage Offset Correction: v_off_ini = 0.000005367 V, v_off_fin = -0.000002268 V 06:34:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175310530 Vs 06:34:21 Temperature Measurement, Probe Number = 0, T = 20.143000 C 06:34:22 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:34:22 Temperature Measurement, Probe Number = 2, T = 19.948000 C 06:34:23 Temperature Measurement, Probe Number = 3, T = 19.939000 C 06:34:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:34:23 Integrated Voltage Measurement... 06:34:42 Voltage Offset Correction: v_off_ini = 0.000001192 V, v_off_fin = 0.000006115 V 06:34:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175425851 Vs 06:34:43 Integrated Voltage Measurement... 06:35:02 Voltage Offset Correction: v_off_ini = 0.000005532 V, v_off_fin = -0.000002268 V 06:35:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175317313 Vs 06:35:05 Temperature Measurement, Probe Number = 0, T = 20.169000 C 06:35:06 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:35:06 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:35:07 Temperature Measurement, Probe Number = 3, T = 19.941000 C 06:35:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.17 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:35:07 Integrated Voltage Measurement... 06:35:26 Voltage Offset Correction: v_off_ini = 0.000001323 V, v_off_fin = 0.000006329 V 06:35:27 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175427379 Vs 06:35:27 Integrated Voltage Measurement... 06:35:46 Voltage Offset Correction: v_off_ini = 0.000005353 V, v_off_fin = -0.000002517 V 06:35:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175308654 Vs 06:35:49 Temperature Measurement, Probe Number = 0, T = 20.203000 C 06:35:50 Temperature Measurement, Probe Number = 1, T = 19.982000 C 06:35:50 Temperature Measurement, Probe Number = 2, T = 19.954000 C 06:35:51 Temperature Measurement, Probe Number = 3, T = 19.943000 C 06:35:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:35:51 Integrated Voltage Measurement... 06:36:10 Voltage Offset Correction: v_off_ini = 0.000000930 V, v_off_fin = 0.000006049 V 06:36:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175429151 Vs 06:36:11 Integrated Voltage Measurement... 06:36:30 Voltage Offset Correction: v_off_ini = 0.000004944 V, v_off_fin = -0.000002526 V 06:36:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306842 Vs 06:36:32 Temperature Measurement, Probe Number = 0, T = 20.160000 C 06:36:33 Temperature Measurement, Probe Number = 1, T = 19.983000 C 06:36:34 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:36:34 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:36:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:36:35 Integrated Voltage Measurement... 06:36:54 Voltage Offset Correction: v_off_ini = 0.000001256 V, v_off_fin = 0.000005654 V 06:36:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432804 Vs 06:36:54 Integrated Voltage Measurement... 06:37:13 Voltage Offset Correction: v_off_ini = 0.000004879 V, v_off_fin = -0.000002074 V 06:37:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175309427 Vs 06:37:16 Temperature Measurement, Probe Number = 0, T = 20.160000 C 06:37:17 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:37:17 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:37:18 Temperature Measurement, Probe Number = 3, T = 19.940000 C 06:37:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.16 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:37:18 Integrated Voltage Measurement... 06:37:38 Voltage Offset Correction: v_off_ini = 0.000001631 V, v_off_fin = 0.000005967 V 06:37:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175428313 Vs 06:37:38 Integrated Voltage Measurement... 06:37:57 Voltage Offset Correction: v_off_ini = 0.000005156 V, v_off_fin = -0.000002103 V 06:37:57 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175301095 Vs 06:38:00 Temperature Measurement, Probe Number = 0, T = 20.190000 C 06:38:00 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:38:01 Temperature Measurement, Probe Number = 2, T = 19.953000 C 06:38:02 Temperature Measurement, Probe Number = 3, T = 19.939000 C 06:38:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:38:02 Integrated Voltage Measurement... 06:38:21 Voltage Offset Correction: v_off_ini = 0.000000661 V, v_off_fin = 0.000005847 V 06:38:21 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175432034 Vs 06:38:21 Integrated Voltage Measurement... 06:38:40 Voltage Offset Correction: v_off_ini = 0.000005532 V, v_off_fin = -0.000002227 V 06:38:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303204 Vs 06:38:43 Temperature Measurement, Probe Number = 0, T = 20.214000 C 06:38:44 Temperature Measurement, Probe Number = 1, T = 19.979000 C 06:38:45 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:38:45 Temperature Measurement, Probe Number = 3, T = 19.940000 C 06:38:45 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:38:46 Integrated Voltage Measurement... 06:39:05 Voltage Offset Correction: v_off_ini = 0.000001084 V, v_off_fin = 0.000005522 V 06:39:05 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431058 Vs 06:39:06 Integrated Voltage Measurement... 06:39:25 Voltage Offset Correction: v_off_ini = 0.000005299 V, v_off_fin = -0.000001454 V 06:39:25 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293301 Vs 06:39:28 Temperature Measurement, Probe Number = 0, T = 20.246000 C 06:39:28 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:39:29 Temperature Measurement, Probe Number = 2, T = 19.950000 C 06:39:30 Temperature Measurement, Probe Number = 3, T = 19.942000 C 06:39:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:39:30 Integrated Voltage Measurement... 06:39:49 Voltage Offset Correction: v_off_ini = 0.000002017 V, v_off_fin = 0.000006202 V 06:39:49 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175431543 Vs 06:39:49 Integrated Voltage Measurement... 06:40:09 Voltage Offset Correction: v_off_ini = 0.000005789 V, v_off_fin = -0.000001244 V 06:40:09 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175301392 Vs 06:40:12 Temperature Measurement, Probe Number = 0, T = 20.268000 C 06:40:12 Temperature Measurement, Probe Number = 1, T = 19.980000 C 06:40:13 Temperature Measurement, Probe Number = 2, T = 19.948000 C 06:40:14 Temperature Measurement, Probe Number = 3, T = 19.941000 C 06:40:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 06:40:14 Integrated Voltage Measurement... 06:40:33 Voltage Offset Correction: v_off_ini = 0.000001760 V, v_off_fin = 0.000005547 V 06:40:33 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175431298 Vs 06:40:33 Integrated Voltage Measurement... 06:40:53 Voltage Offset Correction: v_off_ini = 0.000004782 V, v_off_fin = -0.000002809 V 06:40:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307465 Vs 07:10:56 Temperature Measurement, Probe Number = 0, T = 20.267000 C 07:10:56 Temperature Measurement, Probe Number = 1, T = 19.976000 C 07:10:57 Temperature Measurement, Probe Number = 2, T = 19.951000 C 07:10:58 Temperature Measurement, Probe Number = 3, T = 19.938000 C 07:10:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:10:58 Integrated Voltage Measurement... 07:11:17 Voltage Offset Correction: v_off_ini = 0.000003557 V, v_off_fin = 0.000004893 V 07:11:17 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175512735 Vs 07:11:17 Integrated Voltage Measurement... 07:11:37 Voltage Offset Correction: v_off_ini = 0.000004368 V, v_off_fin = -0.000002297 V 07:11:37 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175307907 Vs 07:11:39 Temperature Measurement, Probe Number = 0, T = 20.278000 C 07:11:40 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:11:41 Temperature Measurement, Probe Number = 2, T = 19.953000 C 07:11:41 Temperature Measurement, Probe Number = 3, T = 19.939000 C 07:11:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:11:42 Integrated Voltage Measurement... 07:12:01 Voltage Offset Correction: v_off_ini = 0.000001607 V, v_off_fin = 0.000005295 V 07:12:01 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175410699 Vs 07:12:01 Integrated Voltage Measurement... 07:12:21 Voltage Offset Correction: v_off_ini = 0.000004718 V, v_off_fin = -0.000002772 V 07:12:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298277 Vs 07:12:23 Temperature Measurement, Probe Number = 0, T = 20.241000 C 07:12:24 Temperature Measurement, Probe Number = 1, T = 19.980000 C 07:12:25 Temperature Measurement, Probe Number = 2, T = 19.956000 C 07:12:25 Temperature Measurement, Probe Number = 3, T = 19.939000 C 07:12:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 07:12:26 Integrated Voltage Measurement... 07:12:45 Voltage Offset Correction: v_off_ini = 0.000001019 V, v_off_fin = 0.000005474 V 07:12:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407937 Vs 07:12:46 Integrated Voltage Measurement... 07:13:05 Voltage Offset Correction: v_off_ini = 0.000004864 V, v_off_fin = -0.000002834 V 07:13:05 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291559 Vs 07:13:08 Temperature Measurement, Probe Number = 0, T = 20.240000 C 07:13:08 Temperature Measurement, Probe Number = 1, T = 19.979000 C 07:13:09 Temperature Measurement, Probe Number = 2, T = 19.956000 C 07:13:10 Temperature Measurement, Probe Number = 3, T = 19.941000 C 07:13:10 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 07:13:10 Integrated Voltage Measurement... 07:13:29 Voltage Offset Correction: v_off_ini = 0.000001708 V, v_off_fin = 0.000005805 V 07:13:29 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175415873 Vs 07:13:29 Integrated Voltage Measurement... 07:13:49 Voltage Offset Correction: v_off_ini = 0.000004862 V, v_off_fin = -0.000002687 V 07:13:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294790 Vs 07:13:51 Temperature Measurement, Probe Number = 0, T = 20.274000 C 07:13:52 Temperature Measurement, Probe Number = 1, T = 19.979000 C 07:13:53 Temperature Measurement, Probe Number = 2, T = 19.953000 C 07:13:53 Temperature Measurement, Probe Number = 3, T = 19.940000 C 07:13:54 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:13:54 Integrated Voltage Measurement... 07:14:13 Voltage Offset Correction: v_off_ini = 0.000000984 V, v_off_fin = 0.000005237 V 07:14:13 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175412993 Vs 07:14:13 Integrated Voltage Measurement... 07:14:33 Voltage Offset Correction: v_off_ini = 0.000004570 V, v_off_fin = -0.000002943 V 07:14:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175306979 Vs 07:14:36 Temperature Measurement, Probe Number = 0, T = 20.253000 C 07:14:36 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:14:37 Temperature Measurement, Probe Number = 2, T = 19.953000 C 07:14:38 Temperature Measurement, Probe Number = 3, T = 19.938000 C 07:14:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:14:38 Integrated Voltage Measurement... 07:14:57 Voltage Offset Correction: v_off_ini = 0.000001396 V, v_off_fin = 0.000005630 V 07:14:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175418073 Vs 07:14:57 Integrated Voltage Measurement... 07:15:16 Voltage Offset Correction: v_off_ini = 0.000004792 V, v_off_fin = -0.000003181 V 07:15:16 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292645 Vs 07:15:19 Temperature Measurement, Probe Number = 0, T = 20.240000 C 07:15:20 Temperature Measurement, Probe Number = 1, T = 19.976000 C 07:15:20 Temperature Measurement, Probe Number = 2, T = 19.952000 C 07:15:21 Temperature Measurement, Probe Number = 3, T = 19.939000 C 07:15:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:15:21 Integrated Voltage Measurement... 07:15:40 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000005512 V 07:15:40 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410464 Vs 07:15:41 Integrated Voltage Measurement... 07:16:00 Voltage Offset Correction: v_off_ini = 0.000004850 V, v_off_fin = -0.000002739 V 07:16:00 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299979 Vs 07:16:03 Temperature Measurement, Probe Number = 0, T = 20.284000 C 07:16:04 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:16:04 Temperature Measurement, Probe Number = 2, T = 19.954000 C 07:16:05 Temperature Measurement, Probe Number = 3, T = 19.939000 C 07:16:05 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:16:05 Integrated Voltage Measurement... 07:16:24 Voltage Offset Correction: v_off_ini = 0.000002334 V, v_off_fin = 0.000005644 V 07:16:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175415041 Vs 07:16:25 Integrated Voltage Measurement... 07:16:44 Voltage Offset Correction: v_off_ini = 0.000004771 V, v_off_fin = -0.000002069 V 07:16:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298017 Vs 07:16:47 Temperature Measurement, Probe Number = 0, T = 20.317000 C 07:16:48 Temperature Measurement, Probe Number = 1, T = 19.978000 C 07:16:48 Temperature Measurement, Probe Number = 2, T = 19.954000 C 07:16:49 Temperature Measurement, Probe Number = 3, T = 19.939000 C 07:16:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:16:49 Integrated Voltage Measurement... 07:17:08 Voltage Offset Correction: v_off_ini = 0.000002452 V, v_off_fin = 0.000005923 V 07:17:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175416524 Vs 07:17:08 Integrated Voltage Measurement... 07:17:27 Voltage Offset Correction: v_off_ini = 0.000005215 V, v_off_fin = -0.000002862 V 07:17:28 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175292969 Vs 07:17:30 Temperature Measurement, Probe Number = 0, T = 20.335000 C 07:17:31 Temperature Measurement, Probe Number = 1, T = 19.981000 C 07:17:32 Temperature Measurement, Probe Number = 2, T = 19.955000 C 07:17:32 Temperature Measurement, Probe Number = 3, T = 19.943000 C 07:17:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.95 P3 = Top 1, Value = 19.94 07:17:33 Integrated Voltage Measurement... 07:17:52 Voltage Offset Correction: v_off_ini = 0.000001510 V, v_off_fin = 0.000005025 V 07:17:52 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412899 Vs 07:17:52 Integrated Voltage Measurement... 07:18:11 Voltage Offset Correction: v_off_ini = 0.000004441 V, v_off_fin = -0.000002920 V 07:18:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305482 Vs 07:48:14 Temperature Measurement, Probe Number = 0, T = 20.351000 C 07:48:15 Temperature Measurement, Probe Number = 1, T = 19.985000 C 07:48:15 Temperature Measurement, Probe Number = 2, T = 19.959000 C 07:48:16 Temperature Measurement, Probe Number = 3, T = 19.944000 C 07:48:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 07:48:16 Integrated Voltage Measurement... 07:48:35 Voltage Offset Correction: v_off_ini = 0.000003309 V, v_off_fin = 0.000005457 V 07:48:35 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175509035 Vs 07:48:36 Integrated Voltage Measurement... 07:48:55 Voltage Offset Correction: v_off_ini = 0.000004837 V, v_off_fin = -0.000003099 V 07:48:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293489 Vs 07:48:58 Temperature Measurement, Probe Number = 0, T = 20.342000 C 07:48:58 Temperature Measurement, Probe Number = 1, T = 19.987000 C 07:48:59 Temperature Measurement, Probe Number = 2, T = 19.959000 C 07:49:00 Temperature Measurement, Probe Number = 3, T = 19.944000 C 07:49:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.94 07:49:00 Integrated Voltage Measurement... 07:49:19 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = 0.000005541 V 07:49:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406758 Vs 07:49:19 Integrated Voltage Measurement... 07:49:38 Voltage Offset Correction: v_off_ini = 0.000004962 V, v_off_fin = -0.000002260 V 07:49:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283802 Vs 07:49:41 Temperature Measurement, Probe Number = 0, T = 20.333000 C 07:49:42 Temperature Measurement, Probe Number = 1, T = 19.988000 C 07:49:42 Temperature Measurement, Probe Number = 2, T = 19.961000 C 07:49:43 Temperature Measurement, Probe Number = 3, T = 19.948000 C 07:49:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:49:43 Integrated Voltage Measurement... 07:50:02 Voltage Offset Correction: v_off_ini = 0.000001419 V, v_off_fin = 0.000005345 V 07:50:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175403177 Vs 07:50:03 Integrated Voltage Measurement... 07:50:22 Voltage Offset Correction: v_off_ini = 0.000004307 V, v_off_fin = -0.000002998 V 07:50:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294394 Vs 07:50:25 Temperature Measurement, Probe Number = 0, T = 20.358000 C 07:50:26 Temperature Measurement, Probe Number = 1, T = 19.989000 C 07:50:26 Temperature Measurement, Probe Number = 2, T = 19.961000 C 07:50:27 Temperature Measurement, Probe Number = 3, T = 19.948000 C 07:50:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:50:27 Integrated Voltage Measurement... 07:50:46 Voltage Offset Correction: v_off_ini = 0.000001059 V, v_off_fin = 0.000005729 V 07:50:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175409744 Vs 07:50:47 Integrated Voltage Measurement... 07:51:06 Voltage Offset Correction: v_off_ini = 0.000004942 V, v_off_fin = -0.000002167 V 07:51:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295292 Vs 07:51:09 Temperature Measurement, Probe Number = 0, T = 20.351000 C 07:51:10 Temperature Measurement, Probe Number = 1, T = 19.984000 C 07:51:10 Temperature Measurement, Probe Number = 2, T = 19.963000 C 07:51:11 Temperature Measurement, Probe Number = 3, T = 19.945000 C 07:51:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 19.98 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:51:11 Integrated Voltage Measurement... 07:51:30 Voltage Offset Correction: v_off_ini = 0.000001284 V, v_off_fin = 0.000006135 V 07:51:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412633 Vs 07:51:31 Integrated Voltage Measurement... 07:51:50 Voltage Offset Correction: v_off_ini = 0.000005102 V, v_off_fin = -0.000001706 V 07:51:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285833 Vs 07:51:53 Temperature Measurement, Probe Number = 0, T = 20.387000 C 07:51:53 Temperature Measurement, Probe Number = 1, T = 19.986000 C 07:51:54 Temperature Measurement, Probe Number = 2, T = 19.962000 C 07:51:54 Temperature Measurement, Probe Number = 3, T = 19.946000 C 07:51:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:51:55 Integrated Voltage Measurement... 07:52:14 Voltage Offset Correction: v_off_ini = 0.000001665 V, v_off_fin = 0.000005479 V 07:52:14 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412204 Vs 07:52:14 Integrated Voltage Measurement... 07:52:33 Voltage Offset Correction: v_off_ini = 0.000004558 V, v_off_fin = -0.000002652 V 07:52:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299978 Vs 07:52:36 Temperature Measurement, Probe Number = 0, T = 20.375000 C 07:52:37 Temperature Measurement, Probe Number = 1, T = 19.987000 C 07:52:38 Temperature Measurement, Probe Number = 2, T = 19.963000 C 07:52:38 Temperature Measurement, Probe Number = 3, T = 19.947000 C 07:52:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:52:38 Integrated Voltage Measurement... 07:52:58 Voltage Offset Correction: v_off_ini = 0.000000384 V, v_off_fin = 0.000005685 V 07:52:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410657 Vs 07:52:59 Integrated Voltage Measurement... 07:53:18 Voltage Offset Correction: v_off_ini = 0.000004814 V, v_off_fin = -0.000002308 V 07:53:18 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175284111 Vs 07:53:20 Temperature Measurement, Probe Number = 0, T = 20.403000 C 07:53:21 Temperature Measurement, Probe Number = 1, T = 19.989000 C 07:53:22 Temperature Measurement, Probe Number = 2, T = 19.964000 C 07:53:22 Temperature Measurement, Probe Number = 3, T = 19.949000 C 07:53:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 07:53:23 Integrated Voltage Measurement... 07:53:42 Voltage Offset Correction: v_off_ini = 0.000000548 V, v_off_fin = 0.000005463 V 07:53:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175407512 Vs 07:53:42 Integrated Voltage Measurement... 07:54:02 Voltage Offset Correction: v_off_ini = 0.000004682 V, v_off_fin = -0.000002874 V 07:54:02 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291422 Vs 07:54:05 Temperature Measurement, Probe Number = 0, T = 20.434000 C 07:54:05 Temperature Measurement, Probe Number = 1, T = 19.990000 C 07:54:06 Temperature Measurement, Probe Number = 2, T = 19.966000 C 07:54:07 Temperature Measurement, Probe Number = 3, T = 19.949000 C 07:54:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.43 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 07:54:07 Integrated Voltage Measurement... 07:54:26 Voltage Offset Correction: v_off_ini = 0.000001246 V, v_off_fin = 0.000005127 V 07:54:26 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175393779 Vs 07:54:26 Integrated Voltage Measurement... 07:54:45 Voltage Offset Correction: v_off_ini = 0.000004405 V, v_off_fin = -0.000002114 V 07:54:46 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175289407 Vs 07:54:48 Temperature Measurement, Probe Number = 0, T = 20.412000 C 07:54:49 Temperature Measurement, Probe Number = 1, T = 19.992000 C 07:54:50 Temperature Measurement, Probe Number = 2, T = 19.966000 C 07:54:50 Temperature Measurement, Probe Number = 3, T = 19.948000 C 07:54:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 07:54:50 Integrated Voltage Measurement... 07:55:10 Voltage Offset Correction: v_off_ini = 0.000001581 V, v_off_fin = 0.000004963 V 07:55:11 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403390 Vs 07:55:11 Integrated Voltage Measurement... 07:55:30 Voltage Offset Correction: v_off_ini = 0.000004244 V, v_off_fin = -0.000002481 V 07:55:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292873 Vs 08:25:33 Temperature Measurement, Probe Number = 0, T = 20.291000 C 08:25:34 Temperature Measurement, Probe Number = 1, T = 19.988000 C 08:25:34 Temperature Measurement, Probe Number = 2, T = 19.965000 C 08:25:35 Temperature Measurement, Probe Number = 3, T = 19.948000 C 08:25:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:25:35 Integrated Voltage Measurement... 08:25:55 Voltage Offset Correction: v_off_ini = 0.000002983 V, v_off_fin = 0.000005205 V 08:25:55 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175506513 Vs 08:25:55 Integrated Voltage Measurement... 08:26:14 Voltage Offset Correction: v_off_ini = 0.000004523 V, v_off_fin = -0.000003498 V 08:26:15 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298395 Vs 08:26:17 Temperature Measurement, Probe Number = 0, T = 20.284000 C 08:26:18 Temperature Measurement, Probe Number = 1, T = 19.988000 C 08:26:19 Temperature Measurement, Probe Number = 2, T = 19.966000 C 08:26:19 Temperature Measurement, Probe Number = 3, T = 19.949000 C 08:26:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:26:20 Integrated Voltage Measurement... 08:26:39 Voltage Offset Correction: v_off_ini = 0.000000347 V, v_off_fin = 0.000004650 V 08:26:40 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175395250 Vs 08:26:40 Integrated Voltage Measurement... 08:26:59 Voltage Offset Correction: v_off_ini = 0.000003850 V, v_off_fin = -0.000002839 V 08:26:59 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285252 Vs 08:27:02 Temperature Measurement, Probe Number = 0, T = 20.213000 C 08:27:02 Temperature Measurement, Probe Number = 1, T = 19.990000 C 08:27:03 Temperature Measurement, Probe Number = 2, T = 19.968000 C 08:27:04 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:27:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:27:04 Integrated Voltage Measurement... 08:27:24 Voltage Offset Correction: v_off_ini = 0.000001252 V, v_off_fin = 0.000005048 V 08:27:24 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399806 Vs 08:27:24 Integrated Voltage Measurement... 08:27:44 Voltage Offset Correction: v_off_ini = 0.000004665 V, v_off_fin = -0.000003286 V 08:27:44 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292464 Vs 08:27:46 Temperature Measurement, Probe Number = 0, T = 20.239000 C 08:27:47 Temperature Measurement, Probe Number = 1, T = 19.992000 C 08:27:48 Temperature Measurement, Probe Number = 2, T = 19.967000 C 08:27:49 Temperature Measurement, Probe Number = 3, T = 19.952000 C 08:27:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:27:49 Integrated Voltage Measurement... 08:28:08 Voltage Offset Correction: v_off_ini = 0.000001283 V, v_off_fin = 0.000006292 V 08:28:08 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175396832 Vs 08:28:08 Integrated Voltage Measurement... 08:28:28 Voltage Offset Correction: v_off_ini = 0.000004885 V, v_off_fin = -0.000001967 V 08:28:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290476 Vs 08:28:30 Temperature Measurement, Probe Number = 0, T = 20.329000 C 08:28:31 Temperature Measurement, Probe Number = 1, T = 19.994000 C 08:28:32 Temperature Measurement, Probe Number = 2, T = 19.968000 C 08:28:32 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:28:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:28:33 Integrated Voltage Measurement... 08:28:52 Voltage Offset Correction: v_off_ini = 0.000001050 V, v_off_fin = 0.000004995 V 08:28:52 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399271 Vs 08:28:52 Integrated Voltage Measurement... 08:29:12 Voltage Offset Correction: v_off_ini = 0.000004354 V, v_off_fin = -0.000003194 V 08:29:12 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175292947 Vs 08:29:15 Temperature Measurement, Probe Number = 0, T = 20.326000 C 08:29:15 Temperature Measurement, Probe Number = 1, T = 19.992000 C 08:29:16 Temperature Measurement, Probe Number = 2, T = 19.967000 C 08:29:17 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:29:17 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:29:17 Integrated Voltage Measurement... 08:29:36 Voltage Offset Correction: v_off_ini = 0.000000757 V, v_off_fin = 0.000004963 V 08:29:36 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175397595 Vs 08:29:36 Integrated Voltage Measurement... 08:29:56 Voltage Offset Correction: v_off_ini = 0.000004162 V, v_off_fin = -0.000002596 V 08:29:56 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175297608 Vs 08:29:59 Temperature Measurement, Probe Number = 0, T = 20.260000 C 08:29:59 Temperature Measurement, Probe Number = 1, T = 19.991000 C 08:30:00 Temperature Measurement, Probe Number = 2, T = 19.967000 C 08:30:01 Temperature Measurement, Probe Number = 3, T = 19.950000 C 08:30:01 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:30:01 Integrated Voltage Measurement... 08:30:20 Voltage Offset Correction: v_off_ini = 0.000001096 V, v_off_fin = 0.000005124 V 08:30:20 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175395206 Vs 08:30:20 Integrated Voltage Measurement... 08:30:39 Voltage Offset Correction: v_off_ini = 0.000004362 V, v_off_fin = -0.000002914 V 08:30:39 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175294364 Vs 08:30:42 Temperature Measurement, Probe Number = 0, T = 20.208000 C 08:30:43 Temperature Measurement, Probe Number = 1, T = 19.989000 C 08:30:43 Temperature Measurement, Probe Number = 2, T = 19.968000 C 08:30:44 Temperature Measurement, Probe Number = 3, T = 19.951000 C 08:30:44 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:30:44 Integrated Voltage Measurement... 08:31:04 Voltage Offset Correction: v_off_ini = 0.000000550 V, v_off_fin = 0.000005299 V 08:31:04 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175398285 Vs 08:31:04 Integrated Voltage Measurement... 08:31:23 Voltage Offset Correction: v_off_ini = 0.000004910 V, v_off_fin = -0.000003100 V 08:31:23 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289936 Vs 08:31:26 Temperature Measurement, Probe Number = 0, T = 20.247000 C 08:31:27 Temperature Measurement, Probe Number = 1, T = 19.988000 C 08:31:27 Temperature Measurement, Probe Number = 2, T = 19.965000 C 08:31:28 Temperature Measurement, Probe Number = 3, T = 19.949000 C 08:31:28 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 08:31:28 Integrated Voltage Measurement... 08:31:47 Voltage Offset Correction: v_off_ini = 0.000001786 V, v_off_fin = 0.000005956 V 08:31:47 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406564 Vs 08:31:48 Integrated Voltage Measurement... 08:32:07 Voltage Offset Correction: v_off_ini = 0.000005241 V, v_off_fin = -0.000001874 V 08:32:07 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175280661 Vs 08:32:10 Temperature Measurement, Probe Number = 0, T = 20.281000 C 08:32:10 Temperature Measurement, Probe Number = 1, T = 19.989000 C 08:32:11 Temperature Measurement, Probe Number = 2, T = 19.968000 C 08:32:12 Temperature Measurement, Probe Number = 3, T = 19.950000 C 08:32:12 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 08:32:12 Integrated Voltage Measurement... 08:32:31 Voltage Offset Correction: v_off_ini = 0.000001513 V, v_off_fin = 0.000006175 V 08:32:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402141 Vs 08:32:31 Integrated Voltage Measurement... 08:32:51 Voltage Offset Correction: v_off_ini = 0.000005089 V, v_off_fin = -0.000002581 V 08:32:51 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280461 Vs 09:02:53 Temperature Measurement, Probe Number = 0, T = 20.292000 C 09:02:54 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:02:55 Temperature Measurement, Probe Number = 2, T = 19.968000 C 09:02:55 Temperature Measurement, Probe Number = 3, T = 19.952000 C 09:02:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:02:56 Integrated Voltage Measurement... 09:03:15 Voltage Offset Correction: v_off_ini = 0.000004253 V, v_off_fin = 0.000005630 V 09:03:15 Integrated Voltage Measurement Delta Gap = 0.0040033 m VT = 0.175498172 Vs 09:03:15 Integrated Voltage Measurement... 09:03:34 Voltage Offset Correction: v_off_ini = 0.000004952 V, v_off_fin = -0.000001730 V 09:03:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175276521 Vs 09:03:37 Temperature Measurement, Probe Number = 0, T = 20.319000 C 09:03:38 Temperature Measurement, Probe Number = 1, T = 19.993000 C 09:03:38 Temperature Measurement, Probe Number = 2, T = 19.968000 C 09:03:39 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:03:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:03:39 Integrated Voltage Measurement... 09:03:58 Voltage Offset Correction: v_off_ini = 0.000001455 V, v_off_fin = 0.000006154 V 09:03:58 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406168 Vs 09:03:59 Integrated Voltage Measurement... 09:04:18 Voltage Offset Correction: v_off_ini = 0.000005245 V, v_off_fin = -0.000001341 V 09:04:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284109 Vs 09:04:21 Temperature Measurement, Probe Number = 0, T = 20.327000 C 09:04:21 Temperature Measurement, Probe Number = 1, T = 19.992000 C 09:04:22 Temperature Measurement, Probe Number = 2, T = 19.966000 C 09:04:23 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:04:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:04:23 Integrated Voltage Measurement... 09:04:42 Voltage Offset Correction: v_off_ini = 0.000001531 V, v_off_fin = 0.000006054 V 09:04:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406733 Vs 09:04:43 Integrated Voltage Measurement... 09:05:02 Voltage Offset Correction: v_off_ini = 0.000005156 V, v_off_fin = -0.000002807 V 09:05:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296705 Vs 09:05:05 Temperature Measurement, Probe Number = 0, T = 20.292000 C 09:05:05 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:05:06 Temperature Measurement, Probe Number = 2, T = 19.969000 C 09:05:07 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:05:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:05:07 Integrated Voltage Measurement... 09:05:26 Voltage Offset Correction: v_off_ini = 0.000001042 V, v_off_fin = 0.000005447 V 09:05:26 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403320 Vs 09:05:26 Integrated Voltage Measurement... 09:05:45 Voltage Offset Correction: v_off_ini = 0.000005359 V, v_off_fin = -0.000002839 V 09:05:45 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175282119 Vs 09:05:48 Temperature Measurement, Probe Number = 0, T = 20.288000 C 09:05:49 Temperature Measurement, Probe Number = 1, T = 19.995000 C 09:05:50 Temperature Measurement, Probe Number = 2, T = 19.968000 C 09:05:50 Temperature Measurement, Probe Number = 3, T = 19.956000 C 09:05:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.96 09:05:50 Integrated Voltage Measurement... 09:06:09 Voltage Offset Correction: v_off_ini = 0.000000650 V, v_off_fin = 0.000005724 V 09:06:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175401703 Vs 09:06:10 Integrated Voltage Measurement... 09:06:29 Voltage Offset Correction: v_off_ini = 0.000004569 V, v_off_fin = -0.000002276 V 09:06:29 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285979 Vs 09:06:32 Temperature Measurement, Probe Number = 0, T = 20.268000 C 09:06:33 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:06:33 Temperature Measurement, Probe Number = 2, T = 19.966000 C 09:06:34 Temperature Measurement, Probe Number = 3, T = 19.952000 C 09:06:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:06:34 Integrated Voltage Measurement... 09:06:53 Voltage Offset Correction: v_off_ini = 0.000000713 V, v_off_fin = 0.000005793 V 09:06:54 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175400595 Vs 09:06:54 Integrated Voltage Measurement... 09:07:13 Voltage Offset Correction: v_off_ini = 0.000004629 V, v_off_fin = -0.000002834 V 09:07:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290002 Vs 09:07:16 Temperature Measurement, Probe Number = 0, T = 20.251000 C 09:07:17 Temperature Measurement, Probe Number = 1, T = 19.993000 C 09:07:17 Temperature Measurement, Probe Number = 2, T = 19.968000 C 09:07:18 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:07:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:07:18 Integrated Voltage Measurement... 09:07:37 Voltage Offset Correction: v_off_ini = 0.000000953 V, v_off_fin = 0.000005181 V 09:07:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175397644 Vs 09:07:38 Integrated Voltage Measurement... 09:07:58 Voltage Offset Correction: v_off_ini = 0.000004362 V, v_off_fin = -0.000002086 V 09:07:58 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175299895 Vs 09:08:00 Temperature Measurement, Probe Number = 0, T = 20.301000 C 09:08:01 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:08:02 Temperature Measurement, Probe Number = 2, T = 19.966000 C 09:08:02 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:08:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:08:03 Integrated Voltage Measurement... 09:08:22 Voltage Offset Correction: v_off_ini = 0.000002187 V, v_off_fin = 0.000005489 V 09:08:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396854 Vs 09:08:22 Integrated Voltage Measurement... 09:08:41 Voltage Offset Correction: v_off_ini = 0.000004794 V, v_off_fin = -0.000003376 V 09:08:41 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293816 Vs 09:08:44 Temperature Measurement, Probe Number = 0, T = 20.356000 C 09:08:45 Temperature Measurement, Probe Number = 1, T = 19.993000 C 09:08:45 Temperature Measurement, Probe Number = 2, T = 19.967000 C 09:08:46 Temperature Measurement, Probe Number = 3, T = 19.954000 C 09:08:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:08:46 Integrated Voltage Measurement... 09:09:06 Voltage Offset Correction: v_off_ini = 0.000000998 V, v_off_fin = 0.000004825 V 09:09:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399841 Vs 09:09:07 Integrated Voltage Measurement... 09:09:26 Voltage Offset Correction: v_off_ini = 0.000004558 V, v_off_fin = -0.000002664 V 09:09:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175285579 Vs 09:09:29 Temperature Measurement, Probe Number = 0, T = 20.363000 C 09:09:29 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:09:30 Temperature Measurement, Probe Number = 2, T = 19.967000 C 09:09:30 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:09:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.36 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:09:31 Integrated Voltage Measurement... 09:09:50 Voltage Offset Correction: v_off_ini = 0.000001388 V, v_off_fin = 0.000005855 V 09:09:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404046 Vs 09:09:50 Integrated Voltage Measurement... 09:10:09 Voltage Offset Correction: v_off_ini = 0.000004127 V, v_off_fin = -0.000003020 V 09:10:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175304442 Vs 09:40:12 Temperature Measurement, Probe Number = 0, T = 20.250000 C 09:40:13 Temperature Measurement, Probe Number = 1, T = 19.993000 C 09:40:14 Temperature Measurement, Probe Number = 2, T = 19.968000 C 09:40:14 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:40:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:40:15 Integrated Voltage Measurement... 09:40:34 Voltage Offset Correction: v_off_ini = 0.000003538 V, v_off_fin = 0.000006064 V 09:40:34 Integrated Voltage Measurement Delta Gap = 0.0040041 m VT = 0.175513635 Vs 09:40:34 Integrated Voltage Measurement... 09:40:53 Voltage Offset Correction: v_off_ini = 0.000004926 V, v_off_fin = -0.000002450 V 09:40:54 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175303662 Vs 09:40:56 Temperature Measurement, Probe Number = 0, T = 20.280000 C 09:40:57 Temperature Measurement, Probe Number = 1, T = 19.996000 C 09:40:58 Temperature Measurement, Probe Number = 2, T = 19.973000 C 09:40:58 Temperature Measurement, Probe Number = 3, T = 19.954000 C 09:40:58 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:40:58 Integrated Voltage Measurement... 09:41:18 Voltage Offset Correction: v_off_ini = 0.000001670 V, v_off_fin = 0.000005163 V 09:41:18 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175396158 Vs 09:41:18 Integrated Voltage Measurement... 09:41:37 Voltage Offset Correction: v_off_ini = 0.000004203 V, v_off_fin = -0.000003681 V 09:41:37 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302821 Vs 09:41:40 Temperature Measurement, Probe Number = 0, T = 20.303000 C 09:41:41 Temperature Measurement, Probe Number = 1, T = 19.997000 C 09:41:42 Temperature Measurement, Probe Number = 2, T = 19.969000 C 09:41:42 Temperature Measurement, Probe Number = 3, T = 19.952000 C 09:41:42 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:41:42 Integrated Voltage Measurement... 09:42:01 Voltage Offset Correction: v_off_ini = 0.000001129 V, v_off_fin = 0.000005235 V 09:42:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399534 Vs 09:42:02 Integrated Voltage Measurement... 09:42:21 Voltage Offset Correction: v_off_ini = 0.000004463 V, v_off_fin = -0.000003044 V 09:42:21 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175292618 Vs 09:42:24 Temperature Measurement, Probe Number = 0, T = 20.319000 C 09:42:24 Temperature Measurement, Probe Number = 1, T = 19.998000 C 09:42:25 Temperature Measurement, Probe Number = 2, T = 19.972000 C 09:42:26 Temperature Measurement, Probe Number = 3, T = 19.951000 C 09:42:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:42:26 Integrated Voltage Measurement... 09:42:45 Voltage Offset Correction: v_off_ini = 0.000000390 V, v_off_fin = 0.000005034 V 09:42:45 Integrated Voltage Measurement Delta Gap = 0.0040014 m VT = 0.175400407 Vs 09:42:45 Integrated Voltage Measurement... 09:43:05 Voltage Offset Correction: v_off_ini = 0.000004720 V, v_off_fin = -0.000002950 V 09:43:05 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175300607 Vs 09:43:07 Temperature Measurement, Probe Number = 0, T = 20.298000 C 09:43:08 Temperature Measurement, Probe Number = 1, T = 19.996000 C 09:43:09 Temperature Measurement, Probe Number = 2, T = 19.970000 C 09:43:09 Temperature Measurement, Probe Number = 3, T = 19.952000 C 09:43:09 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:43:10 Integrated Voltage Measurement... 09:43:29 Voltage Offset Correction: v_off_ini = 0.000000946 V, v_off_fin = 0.000004422 V 09:43:29 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175399381 Vs 09:43:29 Integrated Voltage Measurement... 09:43:48 Voltage Offset Correction: v_off_ini = 0.000003717 V, v_off_fin = -0.000003287 V 09:43:49 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175302954 Vs 09:43:51 Temperature Measurement, Probe Number = 0, T = 20.287000 C 09:43:52 Temperature Measurement, Probe Number = 1, T = 19.998000 C 09:43:53 Temperature Measurement, Probe Number = 2, T = 19.970000 C 09:43:53 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:43:53 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:43:53 Integrated Voltage Measurement... 09:44:13 Voltage Offset Correction: v_off_ini = 0.000000744 V, v_off_fin = 0.000005313 V 09:44:13 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175401641 Vs 09:44:13 Integrated Voltage Measurement... 09:44:33 Voltage Offset Correction: v_off_ini = 0.000003514 V, v_off_fin = -0.000002117 V 09:44:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175305947 Vs 09:44:36 Temperature Measurement, Probe Number = 0, T = 20.265000 C 09:44:36 Temperature Measurement, Probe Number = 1, T = 19.999000 C 09:44:37 Temperature Measurement, Probe Number = 2, T = 19.971000 C 09:44:38 Temperature Measurement, Probe Number = 3, T = 19.954000 C 09:44:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:44:38 Integrated Voltage Measurement... 09:44:57 Voltage Offset Correction: v_off_ini = 0.000001043 V, v_off_fin = 0.000005130 V 09:44:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175396925 Vs 09:44:57 Integrated Voltage Measurement... 09:45:17 Voltage Offset Correction: v_off_ini = 0.000004852 V, v_off_fin = -0.000002706 V 09:45:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175296374 Vs 09:45:20 Temperature Measurement, Probe Number = 0, T = 20.262000 C 09:45:20 Temperature Measurement, Probe Number = 1, T = 19.994000 C 09:45:21 Temperature Measurement, Probe Number = 2, T = 19.970000 C 09:45:21 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:45:21 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:45:22 Integrated Voltage Measurement... 09:45:41 Voltage Offset Correction: v_off_ini = 0.000001420 V, v_off_fin = 0.000005163 V 09:45:41 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405137 Vs 09:45:41 Integrated Voltage Measurement... 09:46:01 Voltage Offset Correction: v_off_ini = 0.000004445 V, v_off_fin = -0.000002443 V 09:46:01 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298220 Vs 09:46:04 Temperature Measurement, Probe Number = 0, T = 20.266000 C 09:46:04 Temperature Measurement, Probe Number = 1, T = 19.996000 C 09:46:05 Temperature Measurement, Probe Number = 2, T = 19.971000 C 09:46:06 Temperature Measurement, Probe Number = 3, T = 19.952000 C 09:46:06 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:46:06 Integrated Voltage Measurement... 09:46:25 Voltage Offset Correction: v_off_ini = 0.000000888 V, v_off_fin = 0.000005540 V 09:46:25 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175400193 Vs 09:46:25 Integrated Voltage Measurement... 09:46:44 Voltage Offset Correction: v_off_ini = 0.000004363 V, v_off_fin = -0.000002319 V 09:46:44 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290724 Vs 09:46:47 Temperature Measurement, Probe Number = 0, T = 20.281000 C 09:46:48 Temperature Measurement, Probe Number = 1, T = 19.999000 C 09:46:48 Temperature Measurement, Probe Number = 2, T = 19.973000 C 09:46:49 Temperature Measurement, Probe Number = 3, T = 19.953000 C 09:46:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.28 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 09:46:49 Integrated Voltage Measurement... 09:47:08 Voltage Offset Correction: v_off_ini = -0.000000663 V, v_off_fin = 0.000005340 V 09:47:08 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403690 Vs 09:47:08 Integrated Voltage Measurement... 09:47:28 Voltage Offset Correction: v_off_ini = 0.000004378 V, v_off_fin = -0.000002468 V 09:47:28 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175288975 Vs 10:17:30 Temperature Measurement, Probe Number = 0, T = 20.259000 C 10:17:31 Temperature Measurement, Probe Number = 1, T = 19.995000 C 10:17:32 Temperature Measurement, Probe Number = 2, T = 19.970000 C 10:17:32 Temperature Measurement, Probe Number = 3, T = 19.951000 C 10:17:32 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:17:33 Integrated Voltage Measurement... 10:17:52 Voltage Offset Correction: v_off_ini = 0.000004318 V, v_off_fin = 0.000005838 V 10:17:52 Integrated Voltage Measurement Delta Gap = 0.0040031 m VT = 0.175502407 Vs 10:17:52 Integrated Voltage Measurement... 10:18:11 Voltage Offset Correction: v_off_ini = 0.000005387 V, v_off_fin = -0.000002788 V 10:18:11 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175293088 Vs 10:18:14 Temperature Measurement, Probe Number = 0, T = 20.245000 C 10:18:15 Temperature Measurement, Probe Number = 1, T = 19.996000 C 10:18:15 Temperature Measurement, Probe Number = 2, T = 19.972000 C 10:18:16 Temperature Measurement, Probe Number = 3, T = 19.951000 C 10:18:16 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:18:16 Integrated Voltage Measurement... 10:18:35 Voltage Offset Correction: v_off_ini = 0.000000775 V, v_off_fin = 0.000005168 V 10:18:35 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175406048 Vs 10:18:36 Integrated Voltage Measurement... 10:18:55 Voltage Offset Correction: v_off_ini = 0.000004815 V, v_off_fin = -0.000002297 V 10:18:55 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294647 Vs 10:18:58 Temperature Measurement, Probe Number = 0, T = 20.252000 C 10:18:58 Temperature Measurement, Probe Number = 1, T = 19.994000 C 10:18:59 Temperature Measurement, Probe Number = 2, T = 19.968000 C 10:19:00 Temperature Measurement, Probe Number = 3, T = 19.950000 C 10:19:00 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:19:00 Integrated Voltage Measurement... 10:19:19 Voltage Offset Correction: v_off_ini = 0.000001721 V, v_off_fin = 0.000005486 V 10:19:19 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175413663 Vs 10:19:19 Integrated Voltage Measurement... 10:19:38 Voltage Offset Correction: v_off_ini = 0.000004843 V, v_off_fin = -0.000000917 V 10:19:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175290310 Vs 10:19:41 Temperature Measurement, Probe Number = 0, T = 20.209000 C 10:19:42 Temperature Measurement, Probe Number = 1, T = 19.994000 C 10:19:43 Temperature Measurement, Probe Number = 2, T = 19.965000 C 10:19:43 Temperature Measurement, Probe Number = 3, T = 19.947000 C 10:19:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.21 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 10:19:43 Integrated Voltage Measurement... 10:20:03 Voltage Offset Correction: v_off_ini = 0.000001149 V, v_off_fin = 0.000005465 V 10:20:03 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175412045 Vs 10:20:03 Integrated Voltage Measurement... 10:20:22 Voltage Offset Correction: v_off_ini = 0.000004688 V, v_off_fin = -0.000004363 V 10:20:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175301564 Vs 10:20:25 Temperature Measurement, Probe Number = 0, T = 20.143000 C 10:20:26 Temperature Measurement, Probe Number = 1, T = 19.993000 C 10:20:26 Temperature Measurement, Probe Number = 2, T = 19.965000 C 10:20:27 Temperature Measurement, Probe Number = 3, T = 19.948000 C 10:20:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.14 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 10:20:27 Integrated Voltage Measurement... 10:20:46 Voltage Offset Correction: v_off_ini = 0.000000346 V, v_off_fin = 0.000005552 V 10:20:46 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175406079 Vs 10:20:47 Integrated Voltage Measurement... 10:21:06 Voltage Offset Correction: v_off_ini = 0.000004960 V, v_off_fin = -0.000002810 V 10:21:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175298111 Vs 10:21:09 Temperature Measurement, Probe Number = 0, T = 20.191000 C 10:21:10 Temperature Measurement, Probe Number = 1, T = 19.992000 C 10:21:10 Temperature Measurement, Probe Number = 2, T = 19.964000 C 10:21:11 Temperature Measurement, Probe Number = 3, T = 19.947000 C 10:21:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.19 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 10:21:11 Integrated Voltage Measurement... 10:21:30 Voltage Offset Correction: v_off_ini = 0.000001818 V, v_off_fin = 0.000005090 V 10:21:31 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405885 Vs 10:21:31 Integrated Voltage Measurement... 10:21:50 Voltage Offset Correction: v_off_ini = 0.000004516 V, v_off_fin = -0.000002537 V 10:21:50 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175293877 Vs 10:21:53 Temperature Measurement, Probe Number = 0, T = 20.216000 C 10:21:54 Temperature Measurement, Probe Number = 1, T = 19.994000 C 10:21:54 Temperature Measurement, Probe Number = 2, T = 19.966000 C 10:21:55 Temperature Measurement, Probe Number = 3, T = 19.948000 C 10:21:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:21:55 Integrated Voltage Measurement... 10:22:14 Voltage Offset Correction: v_off_ini = 0.000001758 V, v_off_fin = 0.000005442 V 10:22:15 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175407955 Vs 10:22:15 Integrated Voltage Measurement... 10:22:34 Voltage Offset Correction: v_off_ini = 0.000004978 V, v_off_fin = -0.000002258 V 10:22:35 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175298651 Vs 10:22:37 Temperature Measurement, Probe Number = 0, T = 20.204000 C 10:22:38 Temperature Measurement, Probe Number = 1, T = 19.994000 C 10:22:39 Temperature Measurement, Probe Number = 2, T = 19.970000 C 10:22:39 Temperature Measurement, Probe Number = 3, T = 19.949000 C 10:22:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.20 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.97 P3 = Top 1, Value = 19.95 10:22:39 Integrated Voltage Measurement... 10:22:58 Voltage Offset Correction: v_off_ini = 0.000001138 V, v_off_fin = 0.000005948 V 10:22:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403272 Vs 10:22:59 Integrated Voltage Measurement... 10:23:18 Voltage Offset Correction: v_off_ini = 0.000004930 V, v_off_fin = -0.000002195 V 10:23:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294873 Vs 10:23:21 Temperature Measurement, Probe Number = 0, T = 20.110000 C 10:23:22 Temperature Measurement, Probe Number = 1, T = 19.991000 C 10:23:22 Temperature Measurement, Probe Number = 2, T = 19.964000 C 10:23:23 Temperature Measurement, Probe Number = 3, T = 19.946000 C 10:23:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.11 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 10:23:23 Integrated Voltage Measurement... 10:23:43 Voltage Offset Correction: v_off_ini = 0.000001457 V, v_off_fin = 0.000006023 V 10:23:43 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175410833 Vs 10:23:43 Integrated Voltage Measurement... 10:24:03 Voltage Offset Correction: v_off_ini = 0.000005046 V, v_off_fin = -0.000002755 V 10:24:03 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175283524 Vs 10:24:05 Temperature Measurement, Probe Number = 0, T = 20.101000 C 10:24:06 Temperature Measurement, Probe Number = 1, T = 19.993000 C 10:24:07 Temperature Measurement, Probe Number = 2, T = 19.964000 C 10:24:07 Temperature Measurement, Probe Number = 3, T = 19.950000 C 10:24:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.10 P1 = Bottom 2, Value = 19.99 P2 = Bottom 3, Value = 19.96 P3 = Top 1, Value = 19.95 10:24:08 Integrated Voltage Measurement... 10:24:27 Voltage Offset Correction: v_off_ini = 0.000001411 V, v_off_fin = 0.000005632 V 10:24:27 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175410391 Vs 10:24:27 Integrated Voltage Measurement... 10:24:46 Voltage Offset Correction: v_off_ini = 0.000005200 V, v_off_fin = -0.000002912 V 10:24:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175294467 Vs 10:54:49 Temperature Measurement, Probe Number = 0, T = 20.238000 C 10:54:50 Temperature Measurement, Probe Number = 1, T = 20.003000 C 10:54:51 Temperature Measurement, Probe Number = 2, T = 19.979000 C 10:54:51 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:54:51 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:54:51 Integrated Voltage Measurement... 10:55:10 Voltage Offset Correction: v_off_ini = 0.000003536 V, v_off_fin = 0.000005436 V 10:55:11 Integrated Voltage Measurement Delta Gap = 0.0040035 m VT = 0.175507660 Vs 10:55:11 Integrated Voltage Measurement... 10:55:30 Voltage Offset Correction: v_off_ini = 0.000004458 V, v_off_fin = -0.000001877 V 10:55:30 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175289804 Vs 10:55:33 Temperature Measurement, Probe Number = 0, T = 20.248000 C 10:55:34 Temperature Measurement, Probe Number = 1, T = 20.003000 C 10:55:35 Temperature Measurement, Probe Number = 2, T = 19.977000 C 10:55:35 Temperature Measurement, Probe Number = 3, T = 19.957000 C 10:55:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:55:35 Integrated Voltage Measurement... 10:55:55 Voltage Offset Correction: v_off_ini = 0.000001472 V, v_off_fin = 0.000005584 V 10:55:55 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175402778 Vs 10:55:55 Integrated Voltage Measurement... 10:56:14 Voltage Offset Correction: v_off_ini = 0.000004684 V, v_off_fin = -0.000002177 V 10:56:14 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175291470 Vs 10:56:17 Temperature Measurement, Probe Number = 0, T = 20.300000 C 10:56:18 Temperature Measurement, Probe Number = 1, T = 20.003000 C 10:56:19 Temperature Measurement, Probe Number = 2, T = 19.978000 C 10:56:19 Temperature Measurement, Probe Number = 3, T = 19.956000 C 10:56:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:56:19 Integrated Voltage Measurement... 10:56:38 Voltage Offset Correction: v_off_ini = 0.000001293 V, v_off_fin = 0.000005517 V 10:56:39 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405419 Vs 10:56:39 Integrated Voltage Measurement... 10:57:00 Voltage Offset Correction: v_off_ini = 0.000005493 V, v_off_fin = -0.000001434 V 10:57:00 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175285517 Vs 10:57:02 Temperature Measurement, Probe Number = 0, T = 20.299000 C 10:57:03 Temperature Measurement, Probe Number = 1, T = 20.003000 C 10:57:04 Temperature Measurement, Probe Number = 2, T = 19.980000 C 10:57:04 Temperature Measurement, Probe Number = 3, T = 19.956000 C 10:57:04 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:57:05 Integrated Voltage Measurement... 10:57:24 Voltage Offset Correction: v_off_ini = 0.000001648 V, v_off_fin = 0.000005145 V 10:57:24 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175384757 Vs 10:57:24 Integrated Voltage Measurement... 10:57:44 Voltage Offset Correction: v_off_ini = 0.000004382 V, v_off_fin = -0.000001534 V 10:57:44 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175289571 Vs 10:57:47 Temperature Measurement, Probe Number = 0, T = 20.233000 C 10:57:48 Temperature Measurement, Probe Number = 1, T = 20.004000 C 10:57:48 Temperature Measurement, Probe Number = 2, T = 19.979000 C 10:57:49 Temperature Measurement, Probe Number = 3, T = 19.959000 C 10:57:49 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:57:49 Integrated Voltage Measurement... 10:58:09 Voltage Offset Correction: v_off_ini = 0.000001412 V, v_off_fin = 0.000005134 V 10:58:09 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175394236 Vs 10:58:09 Integrated Voltage Measurement... 10:58:30 Voltage Offset Correction: v_off_ini = 0.000005145 V, v_off_fin = -0.000000864 V 10:58:30 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175283607 Vs 10:58:32 Temperature Measurement, Probe Number = 0, T = 20.238000 C 10:58:33 Temperature Measurement, Probe Number = 1, T = 20.000000 C 10:58:34 Temperature Measurement, Probe Number = 2, T = 19.983000 C 10:58:34 Temperature Measurement, Probe Number = 3, T = 19.957000 C 10:58:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:58:35 Integrated Voltage Measurement... 10:58:54 Voltage Offset Correction: v_off_ini = 0.000002163 V, v_off_fin = 0.000005693 V 10:58:54 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175393024 Vs 10:58:54 Integrated Voltage Measurement... 10:59:14 Voltage Offset Correction: v_off_ini = 0.000004490 V, v_off_fin = -0.000003096 V 10:59:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295059 Vs 10:59:16 Temperature Measurement, Probe Number = 0, T = 20.264000 C 10:59:17 Temperature Measurement, Probe Number = 1, T = 19.997000 C 10:59:18 Temperature Measurement, Probe Number = 2, T = 19.977000 C 10:59:18 Temperature Measurement, Probe Number = 3, T = 19.956000 C 10:59:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 10:59:19 Integrated Voltage Measurement... 10:59:38 Voltage Offset Correction: v_off_ini = 0.000001976 V, v_off_fin = 0.000005665 V 10:59:38 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404819 Vs 10:59:38 Integrated Voltage Measurement... 10:59:58 Voltage Offset Correction: v_off_ini = 0.000005132 V, v_off_fin = -0.000002502 V 10:59:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175295497 Vs 11:00:00 Temperature Measurement, Probe Number = 0, T = 20.261000 C 11:00:01 Temperature Measurement, Probe Number = 1, T = 20.000000 C 11:00:02 Temperature Measurement, Probe Number = 2, T = 19.975000 C 11:00:02 Temperature Measurement, Probe Number = 3, T = 19.958000 C 11:00:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 11:00:03 Integrated Voltage Measurement... 11:00:22 Voltage Offset Correction: v_off_ini = 0.000001940 V, v_off_fin = 0.000005924 V 11:00:22 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175404183 Vs 11:00:22 Integrated Voltage Measurement... 11:00:42 Voltage Offset Correction: v_off_ini = 0.000005076 V, v_off_fin = -0.000002531 V 11:00:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175290275 Vs 11:00:45 Temperature Measurement, Probe Number = 0, T = 20.263000 C 11:00:45 Temperature Measurement, Probe Number = 1, T = 20.002000 C 11:00:46 Temperature Measurement, Probe Number = 2, T = 19.976000 C 11:00:47 Temperature Measurement, Probe Number = 3, T = 19.959000 C 11:00:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 11:00:47 Integrated Voltage Measurement... 11:01:06 Voltage Offset Correction: v_off_ini = 0.000001685 V, v_off_fin = 0.000005986 V 11:01:06 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175404214 Vs 11:01:06 Integrated Voltage Measurement... 11:01:26 Voltage Offset Correction: v_off_ini = 0.000005172 V, v_off_fin = -0.000002365 V 11:01:26 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299644 Vs 11:01:29 Temperature Measurement, Probe Number = 0, T = 20.314000 C 11:01:29 Temperature Measurement, Probe Number = 1, T = 20.003000 C 11:01:30 Temperature Measurement, Probe Number = 2, T = 19.975000 C 11:01:31 Temperature Measurement, Probe Number = 3, T = 19.957000 C 11:01:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.00 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 11:01:31 Integrated Voltage Measurement... 11:01:50 Voltage Offset Correction: v_off_ini = 0.000001353 V, v_off_fin = 0.000005475 V 11:01:50 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175405658 Vs 11:01:50 Integrated Voltage Measurement... 11:02:10 Voltage Offset Correction: v_off_ini = 0.000004707 V, v_off_fin = -0.000002981 V 11:02:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175299613 Vs 11:32:13 Temperature Measurement, Probe Number = 0, T = 20.488000 C 11:32:14 Temperature Measurement, Probe Number = 1, T = 20.008000 C 11:32:14 Temperature Measurement, Probe Number = 2, T = 19.984000 C 11:32:15 Temperature Measurement, Probe Number = 3, T = 19.963000 C 11:32:15 Magnet Test Parameter Measurements P0 = Room, Value = 20.49 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 11:32:15 Integrated Voltage Measurement... 11:32:34 Voltage Offset Correction: v_off_ini = 0.000002671 V, v_off_fin = 0.000004531 V 11:32:34 Integrated Voltage Measurement Delta Gap = 0.0040039 m VT = 0.175504491 Vs 11:32:35 Integrated Voltage Measurement... 11:32:54 Voltage Offset Correction: v_off_ini = 0.000004241 V, v_off_fin = -0.000004434 V 11:32:54 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175283526 Vs 11:32:56 Temperature Measurement, Probe Number = 0, T = 20.388000 C 11:32:57 Temperature Measurement, Probe Number = 1, T = 20.009000 C 11:32:58 Temperature Measurement, Probe Number = 2, T = 19.987000 C 11:32:58 Temperature Measurement, Probe Number = 3, T = 19.966000 C 11:32:59 Magnet Test Parameter Measurements P0 = Room, Value = 20.39 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:32:59 Integrated Voltage Measurement... 11:33:18 Voltage Offset Correction: v_off_ini = -0.000000671 V, v_off_fin = 0.000004394 V 11:33:18 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175379987 Vs 11:33:18 Integrated Voltage Measurement... 11:33:38 Voltage Offset Correction: v_off_ini = 0.000003857 V, v_off_fin = -0.000002908 V 11:33:38 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285704 Vs 11:33:40 Temperature Measurement, Probe Number = 0, T = 20.306000 C 11:33:41 Temperature Measurement, Probe Number = 1, T = 20.013000 C 11:33:42 Temperature Measurement, Probe Number = 2, T = 19.988000 C 11:33:42 Temperature Measurement, Probe Number = 3, T = 19.969000 C 11:33:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:33:43 Integrated Voltage Measurement... 11:34:02 Voltage Offset Correction: v_off_ini = 0.000000529 V, v_off_fin = 0.000004983 V 11:34:02 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175377454 Vs 11:34:02 Integrated Voltage Measurement... 11:34:22 Voltage Offset Correction: v_off_ini = 0.000004391 V, v_off_fin = -0.000003011 V 11:34:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175281157 Vs 11:34:24 Temperature Measurement, Probe Number = 0, T = 20.343000 C 11:34:25 Temperature Measurement, Probe Number = 1, T = 20.015000 C 11:34:26 Temperature Measurement, Probe Number = 2, T = 19.991000 C 11:34:26 Temperature Measurement, Probe Number = 3, T = 19.971000 C 11:34:26 Magnet Test Parameter Measurements P0 = Room, Value = 20.34 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:34:27 Integrated Voltage Measurement... 11:34:46 Voltage Offset Correction: v_off_ini = 0.000001266 V, v_off_fin = 0.000005518 V 11:34:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175387653 Vs 11:34:47 Integrated Voltage Measurement... 11:35:06 Voltage Offset Correction: v_off_ini = 0.000004531 V, v_off_fin = -0.000002877 V 11:35:06 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175269655 Vs 11:35:09 Temperature Measurement, Probe Number = 0, T = 20.347000 C 11:35:09 Temperature Measurement, Probe Number = 1, T = 20.011000 C 11:35:10 Temperature Measurement, Probe Number = 2, T = 19.989000 C 11:35:11 Temperature Measurement, Probe Number = 3, T = 19.968000 C 11:35:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.35 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:35:11 Integrated Voltage Measurement... 11:35:30 Voltage Offset Correction: v_off_ini = 0.000000833 V, v_off_fin = 0.000005305 V 11:35:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175390844 Vs 11:35:30 Integrated Voltage Measurement... 11:35:50 Voltage Offset Correction: v_off_ini = 0.000004481 V, v_off_fin = -0.000002674 V 11:35:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283974 Vs 11:35:53 Temperature Measurement, Probe Number = 0, T = 20.413000 C 11:35:53 Temperature Measurement, Probe Number = 1, T = 20.008000 C 11:35:54 Temperature Measurement, Probe Number = 2, T = 19.987000 C 11:35:55 Temperature Measurement, Probe Number = 3, T = 19.966000 C 11:35:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.41 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:35:55 Integrated Voltage Measurement... 11:36:14 Voltage Offset Correction: v_off_ini = 0.000002052 V, v_off_fin = 0.000004841 V 11:36:14 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175385387 Vs 11:36:14 Integrated Voltage Measurement... 11:36:33 Voltage Offset Correction: v_off_ini = 0.000003841 V, v_off_fin = -0.000003340 V 11:36:33 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175278800 Vs 11:36:36 Temperature Measurement, Probe Number = 0, T = 20.379000 C 11:36:37 Temperature Measurement, Probe Number = 1, T = 20.006000 C 11:36:38 Temperature Measurement, Probe Number = 2, T = 19.985000 C 11:36:38 Temperature Measurement, Probe Number = 3, T = 19.964000 C 11:36:38 Magnet Test Parameter Measurements P0 = Room, Value = 20.38 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 11:36:38 Integrated Voltage Measurement... 11:36:57 Voltage Offset Correction: v_off_ini = 0.000000893 V, v_off_fin = 0.000004877 V 11:36:57 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175382239 Vs 11:36:58 Integrated Voltage Measurement... 11:37:17 Voltage Offset Correction: v_off_ini = 0.000004521 V, v_off_fin = -0.000002988 V 11:37:17 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175280221 Vs 11:37:20 Temperature Measurement, Probe Number = 0, T = 20.400000 C 11:37:21 Temperature Measurement, Probe Number = 1, T = 20.010000 C 11:37:21 Temperature Measurement, Probe Number = 2, T = 19.989000 C 11:37:22 Temperature Measurement, Probe Number = 3, T = 19.967000 C 11:37:22 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:37:22 Integrated Voltage Measurement... 11:37:42 Voltage Offset Correction: v_off_ini = 0.000000913 V, v_off_fin = 0.000004909 V 11:37:42 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175378169 Vs 11:37:42 Integrated Voltage Measurement... 11:38:02 Voltage Offset Correction: v_off_ini = 0.000004136 V, v_off_fin = -0.000003001 V 11:38:02 Integrated Voltage Measurement Delta Gap = -0.0040007 m VT = -0.175272479 Vs 11:38:05 Temperature Measurement, Probe Number = 0, T = 20.451000 C 11:38:06 Temperature Measurement, Probe Number = 1, T = 20.013000 C 11:38:06 Temperature Measurement, Probe Number = 2, T = 19.990000 C 11:38:07 Temperature Measurement, Probe Number = 3, T = 19.967000 C 11:38:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.45 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:38:07 Integrated Voltage Measurement... 11:38:26 Voltage Offset Correction: v_off_ini = 0.000001240 V, v_off_fin = 0.000005200 V 11:38:26 Integrated Voltage Measurement Delta Gap = 0.0040010 m VT = 0.175372262 Vs 11:38:26 Integrated Voltage Measurement... 11:38:45 Voltage Offset Correction: v_off_ini = 0.000004471 V, v_off_fin = -0.000003350 V 11:38:46 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175273699 Vs 11:38:48 Temperature Measurement, Probe Number = 0, T = 20.398000 C 11:38:49 Temperature Measurement, Probe Number = 1, T = 20.009000 C 11:38:50 Temperature Measurement, Probe Number = 2, T = 19.987000 C 11:38:50 Temperature Measurement, Probe Number = 3, T = 19.968000 C 11:38:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.40 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 11:38:51 Integrated Voltage Measurement... 11:39:09 Voltage Offset Correction: v_off_ini = 0.000000564 V, v_off_fin = 0.000005352 V 11:39:10 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175381037 Vs 11:39:10 Integrated Voltage Measurement... 11:39:29 Voltage Offset Correction: v_off_ini = 0.000004767 V, v_off_fin = -0.000003450 V 11:39:29 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175281887 Vs 12:09:32 Temperature Measurement, Probe Number = 0, T = 20.221000 C 12:09:33 Temperature Measurement, Probe Number = 1, T = 20.009000 C 12:09:33 Temperature Measurement, Probe Number = 2, T = 19.983000 C 12:09:34 Temperature Measurement, Probe Number = 3, T = 19.965000 C 12:09:34 Magnet Test Parameter Measurements P0 = Room, Value = 20.22 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.98 P3 = Top 1, Value = 19.96 12:09:34 Integrated Voltage Measurement... 12:09:53 Voltage Offset Correction: v_off_ini = 0.000003833 V, v_off_fin = 0.000005336 V 12:09:54 Integrated Voltage Measurement Delta Gap = 0.0040032 m VT = 0.175484249 Vs 12:09:54 Integrated Voltage Measurement... 12:10:13 Voltage Offset Correction: v_off_ini = 0.000005256 V, v_off_fin = -0.000002708 V 12:10:13 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175272868 Vs 12:10:16 Temperature Measurement, Probe Number = 0, T = 20.273000 C 12:10:17 Temperature Measurement, Probe Number = 1, T = 20.011000 C 12:10:17 Temperature Measurement, Probe Number = 2, T = 19.986000 C 12:10:18 Temperature Measurement, Probe Number = 3, T = 19.967000 C 12:10:18 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:10:18 Integrated Voltage Measurement... 12:10:37 Voltage Offset Correction: v_off_ini = 0.000000709 V, v_off_fin = 0.000005414 V 12:10:38 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175376458 Vs 12:10:38 Integrated Voltage Measurement... 12:10:57 Voltage Offset Correction: v_off_ini = 0.000004882 V, v_off_fin = -0.000002465 V 12:10:57 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175273926 Vs 12:11:00 Temperature Measurement, Probe Number = 0, T = 20.267000 C 12:11:01 Temperature Measurement, Probe Number = 1, T = 20.013000 C 12:11:01 Temperature Measurement, Probe Number = 2, T = 19.992000 C 12:11:02 Temperature Measurement, Probe Number = 3, T = 19.969000 C 12:11:02 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:11:02 Integrated Voltage Measurement... 12:11:21 Voltage Offset Correction: v_off_ini = 0.000001258 V, v_off_fin = 0.000005605 V 12:11:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175391636 Vs 12:11:22 Integrated Voltage Measurement... 12:11:41 Voltage Offset Correction: v_off_ini = 0.000004631 V, v_off_fin = -0.000001828 V 12:11:42 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175280865 Vs 12:11:44 Temperature Measurement, Probe Number = 0, T = 20.312000 C 12:11:45 Temperature Measurement, Probe Number = 1, T = 20.017000 C 12:11:46 Temperature Measurement, Probe Number = 2, T = 19.992000 C 12:11:46 Temperature Measurement, Probe Number = 3, T = 19.974000 C 12:11:46 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:11:47 Integrated Voltage Measurement... 12:12:06 Voltage Offset Correction: v_off_ini = 0.000001640 V, v_off_fin = 0.000005666 V 12:12:06 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175382934 Vs 12:12:06 Integrated Voltage Measurement... 12:12:25 Voltage Offset Correction: v_off_ini = 0.000004957 V, v_off_fin = -0.000002393 V 12:12:25 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175278259 Vs 12:12:28 Temperature Measurement, Probe Number = 0, T = 20.322000 C 12:12:29 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:12:29 Temperature Measurement, Probe Number = 2, T = 19.991000 C 12:12:30 Temperature Measurement, Probe Number = 3, T = 19.970000 C 12:12:30 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:12:30 Integrated Voltage Measurement... 12:12:49 Voltage Offset Correction: v_off_ini = 0.000000481 V, v_off_fin = 0.000005140 V 12:12:49 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175381938 Vs 12:12:50 Integrated Voltage Measurement... 12:13:09 Voltage Offset Correction: v_off_ini = 0.000004348 V, v_off_fin = -0.000002384 V 12:13:09 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279824 Vs 12:13:11 Temperature Measurement, Probe Number = 0, T = 20.323000 C 12:13:12 Temperature Measurement, Probe Number = 1, T = 20.018000 C 12:13:13 Temperature Measurement, Probe Number = 2, T = 19.993000 C 12:13:13 Temperature Measurement, Probe Number = 3, T = 19.970000 C 12:13:14 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:13:14 Integrated Voltage Measurement... 12:13:33 Voltage Offset Correction: v_off_ini = 0.000001253 V, v_off_fin = 0.000005329 V 12:13:33 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175387279 Vs 12:13:33 Integrated Voltage Measurement... 12:13:53 Voltage Offset Correction: v_off_ini = 0.000004321 V, v_off_fin = -0.000002394 V 12:13:53 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175275515 Vs 12:13:55 Temperature Measurement, Probe Number = 0, T = 20.373000 C 12:13:56 Temperature Measurement, Probe Number = 1, T = 20.018000 C 12:13:57 Temperature Measurement, Probe Number = 2, T = 19.993000 C 12:13:57 Temperature Measurement, Probe Number = 3, T = 19.967000 C 12:13:57 Magnet Test Parameter Measurements P0 = Room, Value = 20.37 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:13:58 Integrated Voltage Measurement... 12:14:17 Voltage Offset Correction: v_off_ini = 0.000001108 V, v_off_fin = 0.000005629 V 12:14:17 Integrated Voltage Measurement Delta Gap = 0.0040011 m VT = 0.175383294 Vs 12:14:18 Integrated Voltage Measurement... 12:14:38 Voltage Offset Correction: v_off_ini = 0.000004219 V, v_off_fin = -0.000000366 V 12:14:38 Integrated Voltage Measurement Delta Gap = -0.0040006 m VT = -0.175273273 Vs 12:14:41 Temperature Measurement, Probe Number = 0, T = 20.328000 C 12:14:42 Temperature Measurement, Probe Number = 1, T = 20.013000 C 12:14:42 Temperature Measurement, Probe Number = 2, T = 19.990000 C 12:14:43 Temperature Measurement, Probe Number = 3, T = 19.966000 C 12:14:43 Magnet Test Parameter Measurements P0 = Room, Value = 20.33 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:14:43 Integrated Voltage Measurement... 12:15:03 Voltage Offset Correction: v_off_ini = 0.000002063 V, v_off_fin = 0.000005343 V 12:15:03 Integrated Voltage Measurement Delta Gap = 0.0040009 m VT = 0.175374740 Vs 12:15:03 Integrated Voltage Measurement... 12:15:22 Voltage Offset Correction: v_off_ini = 0.000004628 V, v_off_fin = -0.000005303 V 12:15:22 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175274645 Vs 12:15:25 Temperature Measurement, Probe Number = 0, T = 20.302000 C 12:15:26 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:15:26 Temperature Measurement, Probe Number = 2, T = 19.989000 C 12:15:27 Temperature Measurement, Probe Number = 3, T = 19.968000 C 12:15:27 Magnet Test Parameter Measurements P0 = Room, Value = 20.30 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:15:27 Integrated Voltage Measurement... 12:15:47 Voltage Offset Correction: v_off_ini = 0.000001063 V, v_off_fin = 0.000005498 V 12:15:47 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175390506 Vs 12:15:47 Integrated Voltage Measurement... 12:16:06 Voltage Offset Correction: v_off_ini = 0.000004700 V, v_off_fin = -0.000003059 V 12:16:06 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175270450 Vs 12:16:09 Temperature Measurement, Probe Number = 0, T = 20.318000 C 12:16:10 Temperature Measurement, Probe Number = 1, T = 20.018000 C 12:16:10 Temperature Measurement, Probe Number = 2, T = 19.993000 C 12:16:11 Temperature Measurement, Probe Number = 3, T = 19.968000 C 12:16:11 Magnet Test Parameter Measurements P0 = Room, Value = 20.32 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:16:11 Integrated Voltage Measurement... 12:16:30 Voltage Offset Correction: v_off_ini = 0.000000559 V, v_off_fin = 0.000004995 V 12:16:30 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175383017 Vs 12:16:30 Integrated Voltage Measurement... 12:16:50 Voltage Offset Correction: v_off_ini = 0.000004464 V, v_off_fin = -0.000002495 V 12:16:50 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175283394 Vs 12:46:53 Temperature Measurement, Probe Number = 0, T = 20.241000 C 12:46:53 Temperature Measurement, Probe Number = 1, T = 20.013000 C 12:46:54 Temperature Measurement, Probe Number = 2, T = 19.987000 C 12:46:55 Temperature Measurement, Probe Number = 3, T = 19.965000 C 12:46:55 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 12:46:55 Integrated Voltage Measurement... 12:47:14 Voltage Offset Correction: v_off_ini = 0.000003401 V, v_off_fin = 0.000005212 V 12:47:14 Integrated Voltage Measurement Delta Gap = 0.0040029 m VT = 0.175472386 Vs 12:47:14 Integrated Voltage Measurement... 12:47:33 Voltage Offset Correction: v_off_ini = 0.000004422 V, v_off_fin = -0.000003020 V 12:47:34 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284446 Vs 12:47:36 Temperature Measurement, Probe Number = 0, T = 20.234000 C 12:47:37 Temperature Measurement, Probe Number = 1, T = 20.013000 C 12:47:38 Temperature Measurement, Probe Number = 2, T = 19.987000 C 12:47:38 Temperature Measurement, Probe Number = 3, T = 19.969000 C 12:47:39 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.01 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:47:39 Integrated Voltage Measurement... 12:47:58 Voltage Offset Correction: v_off_ini = 0.000000069 V, v_off_fin = 0.000005002 V 12:47:59 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175387683 Vs 12:47:59 Integrated Voltage Measurement... 12:48:18 Voltage Offset Correction: v_off_ini = 0.000004654 V, v_off_fin = -0.000002513 V 12:48:18 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175279548 Vs 12:48:21 Temperature Measurement, Probe Number = 0, T = 20.228000 C 12:48:22 Temperature Measurement, Probe Number = 1, T = 20.016000 C 12:48:22 Temperature Measurement, Probe Number = 2, T = 19.993000 C 12:48:23 Temperature Measurement, Probe Number = 3, T = 19.964000 C 12:48:23 Magnet Test Parameter Measurements P0 = Room, Value = 20.23 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 12:48:23 Integrated Voltage Measurement... 12:48:42 Voltage Offset Correction: v_off_ini = 0.000001960 V, v_off_fin = 0.000005653 V 12:48:42 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175400309 Vs 12:48:42 Integrated Voltage Measurement... 12:49:02 Voltage Offset Correction: v_off_ini = 0.000005566 V, v_off_fin = -0.000001476 V 12:49:02 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175277638 Vs 12:49:04 Temperature Measurement, Probe Number = 0, T = 20.257000 C 12:49:05 Temperature Measurement, Probe Number = 1, T = 20.016000 C 12:49:06 Temperature Measurement, Probe Number = 2, T = 19.994000 C 12:49:06 Temperature Measurement, Probe Number = 3, T = 19.967000 C 12:49:07 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:49:07 Integrated Voltage Measurement... 12:49:26 Voltage Offset Correction: v_off_ini = 0.000001433 V, v_off_fin = 0.000005820 V 12:49:26 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175402341 Vs 12:49:26 Integrated Voltage Measurement... 12:49:45 Voltage Offset Correction: v_off_ini = 0.000005049 V, v_off_fin = -0.000001949 V 12:49:45 Integrated Voltage Measurement Delta Gap = -0.0040010 m VT = -0.175276487 Vs 12:49:48 Temperature Measurement, Probe Number = 0, T = 20.292000 C 12:49:49 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:49:49 Temperature Measurement, Probe Number = 2, T = 19.986000 C 12:49:50 Temperature Measurement, Probe Number = 3, T = 19.963000 C 12:49:50 Magnet Test Parameter Measurements P0 = Room, Value = 20.29 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 12:49:50 Integrated Voltage Measurement... 12:50:10 Voltage Offset Correction: v_off_ini = 0.000001210 V, v_off_fin = 0.000005345 V 12:50:10 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175403834 Vs 12:50:10 Integrated Voltage Measurement... 12:50:30 Voltage Offset Correction: v_off_ini = 0.000005185 V, v_off_fin = -0.000002710 V 12:50:30 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175281083 Vs 12:50:33 Temperature Measurement, Probe Number = 0, T = 20.258000 C 12:50:33 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:50:34 Temperature Measurement, Probe Number = 2, T = 19.986000 C 12:50:34 Temperature Measurement, Probe Number = 3, T = 19.965000 C 12:50:35 Magnet Test Parameter Measurements P0 = Room, Value = 20.26 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.96 12:50:35 Integrated Voltage Measurement... 12:50:54 Voltage Offset Correction: v_off_ini = 0.000000719 V, v_off_fin = 0.000005056 V 12:50:54 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175394821 Vs 12:50:55 Integrated Voltage Measurement... 12:51:14 Voltage Offset Correction: v_off_ini = 0.000004389 V, v_off_fin = -0.000002452 V 12:51:14 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284443 Vs 12:51:17 Temperature Measurement, Probe Number = 0, T = 20.268000 C 12:51:17 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:51:18 Temperature Measurement, Probe Number = 2, T = 19.988000 C 12:51:19 Temperature Measurement, Probe Number = 3, T = 19.969000 C 12:51:19 Magnet Test Parameter Measurements P0 = Room, Value = 20.27 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:51:19 Integrated Voltage Measurement... 12:51:38 Voltage Offset Correction: v_off_ini = 0.000001452 V, v_off_fin = 0.000005350 V 12:51:38 Integrated Voltage Measurement Delta Gap = 0.0040013 m VT = 0.175393967 Vs 12:51:39 Integrated Voltage Measurement... 12:51:58 Voltage Offset Correction: v_off_ini = 0.000004330 V, v_off_fin = -0.000002884 V 12:51:58 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175284030 Vs 12:52:01 Temperature Measurement, Probe Number = 0, T = 20.238000 C 12:52:02 Temperature Measurement, Probe Number = 1, T = 20.016000 C 12:52:02 Temperature Measurement, Probe Number = 2, T = 19.991000 C 12:52:03 Temperature Measurement, Probe Number = 3, T = 19.971000 C 12:52:03 Magnet Test Parameter Measurements P0 = Room, Value = 20.24 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:52:03 Integrated Voltage Measurement... 12:52:22 Voltage Offset Correction: v_off_ini = 0.000000648 V, v_off_fin = 0.000005233 V 12:52:22 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175391375 Vs 12:52:23 Integrated Voltage Measurement... 12:52:42 Voltage Offset Correction: v_off_ini = 0.000004417 V, v_off_fin = -0.000002196 V 12:52:42 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175285210 Vs 12:52:45 Temperature Measurement, Probe Number = 0, T = 20.248000 C 12:52:46 Temperature Measurement, Probe Number = 1, T = 20.015000 C 12:52:46 Temperature Measurement, Probe Number = 2, T = 19.992000 C 12:52:47 Temperature Measurement, Probe Number = 3, T = 19.971000 C 12:52:47 Magnet Test Parameter Measurements P0 = Room, Value = 20.25 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:52:47 Integrated Voltage Measurement... 12:53:06 Voltage Offset Correction: v_off_ini = 0.000000704 V, v_off_fin = 0.000005503 V 12:53:07 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175397755 Vs 12:53:07 Integrated Voltage Measurement... 12:53:26 Voltage Offset Correction: v_off_ini = 0.000004847 V, v_off_fin = -0.000001568 V 12:53:26 Integrated Voltage Measurement Delta Gap = -0.0040008 m VT = -0.175282454 Vs 12:53:29 Temperature Measurement, Probe Number = 0, T = 20.309000 C 12:53:30 Temperature Measurement, Probe Number = 1, T = 20.018000 C 12:53:30 Temperature Measurement, Probe Number = 2, T = 19.991000 C 12:53:31 Temperature Measurement, Probe Number = 3, T = 19.973000 C 12:53:31 Magnet Test Parameter Measurements P0 = Room, Value = 20.31 P1 = Bottom 2, Value = 20.02 P2 = Bottom 3, Value = 19.99 P3 = Top 1, Value = 19.97 12:53:31 Integrated Voltage Measurement... 12:53:50 Voltage Offset Correction: v_off_ini = 0.000001195 V, v_off_fin = 0.000005592 V 12:53:51 Integrated Voltage Measurement Delta Gap = 0.0040012 m VT = 0.175389081 Vs 12:53:51 Integrated Voltage Measurement... 12:54:10 Voltage Offset Correction: v_off_ini = 0.000004960 V, v_off_fin = -0.000002475 V 12:54:10 Integrated Voltage Measurement Delta Gap = -0.0040009 m VT = -0.175278700 Vs