SLAC Magnetic Measurements Date: 02-15-2018 Time: 17:56:59 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 87 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=1.3 s Coil attached with tape. Offset corr: TRUE 17:56:59 Ambient Measurement Device(s) Being Used, type = None 17:56:59 Magnet Voltage Measurement Device(s) Being Used, type = None 17:56:59 Temperature Measurement Device(s) Being Used, type = None 17:56:59 XMAG Device(s) Being Used, type = None 17:56:59 Ambient Measurement Device(s) Being Used, type = None 17:57:13 Magnet Test Parameter Measurements 17:57:13 Integrated Voltage Measurement... 17:57:30 Voltage Offset Correction: v_off_ini = -0.000001720 V, v_off_fin = 0.000066878 V 17:57:30 Integrated Voltage Measurement Delta Gap = 0.0040001 m VT = -0.174129288 Vs 17:57:30 Integrated Voltage Measurement... 17:57:45 Voltage Offset Correction: v_off_ini = -0.000005117 V, v_off_fin = 0.000053625 V 17:57:45 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.174661210 Vs 17:57:48 Magnet Test Parameter Measurements 17:57:48 Integrated Voltage Measurement... 17:58:03 Voltage Offset Correction: v_off_ini = -0.000002007 V, v_off_fin = 0.000073866 V 17:58:04 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174164820 Vs 17:58:04 Integrated Voltage Measurement... 17:58:19 Voltage Offset Correction: v_off_ini = -0.000006202 V, v_off_fin = 0.000058952 V 17:58:19 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.174648745 Vs 17:58:21 Magnet Test Parameter Measurements 17:58:22 Integrated Voltage Measurement... 17:58:37 Voltage Offset Correction: v_off_ini = -0.000002766 V, v_off_fin = 0.000072955 V 17:58:37 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174141734 Vs 17:58:37 Integrated Voltage Measurement... 17:58:53 Voltage Offset Correction: v_off_ini = -0.000006967 V, v_off_fin = 0.000054687 V 17:58:53 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.174682659 Vs 17:58:55 Magnet Test Parameter Measurements 17:58:55 Integrated Voltage Measurement... 17:59:11 Voltage Offset Correction: v_off_ini = -0.000001788 V, v_off_fin = 0.000065574 V 17:59:11 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174102862 Vs 17:59:11 Integrated Voltage Measurement... 17:59:27 Voltage Offset Correction: v_off_ini = -0.000005261 V, v_off_fin = 0.000058348 V 17:59:27 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.174650705 Vs 17:59:29 Magnet Test Parameter Measurements 17:59:29 Integrated Voltage Measurement... 17:59:45 Voltage Offset Correction: v_off_ini = -0.000003397 V, v_off_fin = 0.000064891 V 17:59:45 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174081241 Vs 17:59:45 Integrated Voltage Measurement... 18:00:01 Voltage Offset Correction: v_off_ini = -0.000006276 V, v_off_fin = 0.000057460 V 18:00:01 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.174659519 Vs 18:00:03 Magnet Test Parameter Measurements 18:00:03 Integrated Voltage Measurement... 18:00:19 Voltage Offset Correction: v_off_ini = -0.000003023 V, v_off_fin = 0.000063624 V 18:00:19 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174083238 Vs 18:00:19 Integrated Voltage Measurement... 18:00:35 Voltage Offset Correction: v_off_ini = -0.000006200 V, v_off_fin = 0.000054439 V 18:00:35 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.174686695 Vs 18:00:37 Magnet Test Parameter Measurements 18:00:37 Integrated Voltage Measurement... 18:00:53 Voltage Offset Correction: v_off_ini = -0.000004573 V, v_off_fin = 0.000068147 V 18:00:53 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174093647 Vs 18:00:53 Integrated Voltage Measurement... 18:01:09 Voltage Offset Correction: v_off_ini = -0.000005275 V, v_off_fin = 0.000052892 V 18:01:09 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.174687426 Vs 18:01:11 Magnet Test Parameter Measurements 18:01:11 Integrated Voltage Measurement... 18:01:27 Voltage Offset Correction: v_off_ini = -0.000003058 V, v_off_fin = 0.000071906 V 18:01:27 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174111334 Vs 18:01:27 Integrated Voltage Measurement... 18:01:43 Voltage Offset Correction: v_off_ini = -0.000005572 V, v_off_fin = 0.000055361 V 18:01:43 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.174677946 Vs 18:01:45 Magnet Test Parameter Measurements 18:01:45 Integrated Voltage Measurement... 18:02:01 Voltage Offset Correction: v_off_ini = -0.000003068 V, v_off_fin = 0.000065267 V 18:02:01 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174080554 Vs 18:02:01 Integrated Voltage Measurement... 18:02:17 Voltage Offset Correction: v_off_ini = -0.000004985 V, v_off_fin = 0.000053618 V 18:02:17 Integrated Voltage Measurement Delta Gap = -0.0040001 m VT = 0.174679430 Vs 18:02:19 Magnet Test Parameter Measurements 18:02:19 Integrated Voltage Measurement... 18:02:35 Voltage Offset Correction: v_off_ini = -0.000003778 V, v_off_fin = 0.000065568 V 18:02:35 Integrated Voltage Measurement Delta Gap = 0.0040003 m VT = -0.174088193 Vs 18:02:35 Integrated Voltage Measurement... 18:02:51 Voltage Offset Correction: v_off_ini = -0.000005641 V, v_off_fin = 0.000048227 V 18:02:51 Integrated Voltage Measurement Delta Gap = -0.0040002 m VT = 0.174712561 Vs