SLAC Magnetic Measurements Date: 02-15-2018 Time: 21:44:02 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 113 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=3.2 s Coil attached with tape. Offset corr: TRUE Samples offset corr.: 20 21:44:02 Ambient Measurement Device(s) Being Used, type = None 21:44:02 Magnet Voltage Measurement Device(s) Being Used, type = None 21:44:02 Temperature Measurement Device(s) Being Used, type = None 21:44:02 XMAG Device(s) Being Used, type = None 21:44:02 Ambient Measurement Device(s) Being Used, type = None 21:44:04 Magnet Test Parameter Measurements 21:44:04 Integrated Voltage Measurement... 21:44:19 Voltage Offset Correction: v_off_ini = -0.000005746 V, v_off_fin = -0.000006691 V 21:44:19 Integrated Voltage Measurement Delta Gap = 0.0020007 m VT = -0.099718150 Vs 21:44:19 Integrated Voltage Measurement... 21:44:32 Voltage Offset Correction: v_off_ini = -0.000007356 V, v_off_fin = -0.000001228 V 21:44:32 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100661005 Vs 21:44:34 Magnet Test Parameter Measurements 21:44:34 Integrated Voltage Measurement... 21:44:47 Voltage Offset Correction: v_off_ini = -0.000004638 V, v_off_fin = -0.000005783 V 21:44:47 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099744504 Vs 21:44:47 Integrated Voltage Measurement... 21:45:00 Voltage Offset Correction: v_off_ini = -0.000006919 V, v_off_fin = -0.000002252 V 21:45:00 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100680522 Vs 21:45:02 Magnet Test Parameter Measurements 21:45:02 Integrated Voltage Measurement... 21:45:14 Voltage Offset Correction: v_off_ini = -0.000004905 V, v_off_fin = -0.000006665 V 21:45:14 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099756864 Vs 21:45:15 Integrated Voltage Measurement... 21:45:27 Voltage Offset Correction: v_off_ini = -0.000006051 V, v_off_fin = -0.000003860 V 21:45:27 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100678471 Vs 21:45:30 Magnet Test Parameter Measurements 21:45:30 Integrated Voltage Measurement... 21:45:42 Voltage Offset Correction: v_off_ini = -0.000004730 V, v_off_fin = -0.000006194 V 21:45:42 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099731210 Vs 21:45:42 Integrated Voltage Measurement... 21:45:55 Voltage Offset Correction: v_off_ini = -0.000006124 V, v_off_fin = -0.000002731 V 21:45:55 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100660880 Vs 21:45:57 Magnet Test Parameter Measurements 21:45:57 Integrated Voltage Measurement... 21:46:10 Voltage Offset Correction: v_off_ini = -0.000003802 V, v_off_fin = -0.000006511 V 21:46:10 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099749922 Vs 21:46:10 Integrated Voltage Measurement... 21:46:23 Voltage Offset Correction: v_off_ini = -0.000005228 V, v_off_fin = -0.000001038 V 21:46:23 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100664421 Vs 21:46:25 Magnet Test Parameter Measurements 21:46:25 Integrated Voltage Measurement... 21:46:37 Voltage Offset Correction: v_off_ini = -0.000004072 V, v_off_fin = -0.000005904 V 21:46:37 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099745193 Vs 21:46:38 Integrated Voltage Measurement... 21:46:50 Voltage Offset Correction: v_off_ini = -0.000005563 V, v_off_fin = -0.000001188 V 21:46:50 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100650262 Vs 21:46:52 Magnet Test Parameter Measurements 21:46:52 Integrated Voltage Measurement... 21:47:05 Voltage Offset Correction: v_off_ini = -0.000003695 V, v_off_fin = -0.000006250 V 21:47:05 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099742861 Vs 21:47:05 Integrated Voltage Measurement... 21:47:18 Voltage Offset Correction: v_off_ini = -0.000004525 V, v_off_fin = -0.000002670 V 21:47:18 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100665186 Vs 21:47:20 Magnet Test Parameter Measurements 21:47:20 Integrated Voltage Measurement... 21:47:32 Voltage Offset Correction: v_off_ini = -0.000005112 V, v_off_fin = -0.000005899 V 21:47:33 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099734068 Vs 21:47:33 Integrated Voltage Measurement... 21:47:45 Voltage Offset Correction: v_off_ini = -0.000005010 V, v_off_fin = -0.000002707 V 21:47:45 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100670873 Vs 21:47:48 Magnet Test Parameter Measurements 21:47:48 Integrated Voltage Measurement... 21:48:00 Voltage Offset Correction: v_off_ini = -0.000003874 V, v_off_fin = -0.000005433 V 21:48:00 Integrated Voltage Measurement Delta Gap = 0.0020004 m VT = -0.099746628 Vs 21:48:00 Integrated Voltage Measurement... 21:48:13 Voltage Offset Correction: v_off_ini = -0.000005674 V, v_off_fin = -0.000001396 V 21:48:13 Integrated Voltage Measurement Delta Gap = -0.0020002 m VT = 0.100658644 Vs 21:48:15 Magnet Test Parameter Measurements 21:48:15 Integrated Voltage Measurement... 21:48:28 Voltage Offset Correction: v_off_ini = -0.000003067 V, v_off_fin = -0.000006345 V 21:48:28 Integrated Voltage Measurement Delta Gap = 0.0020003 m VT = -0.099725182 Vs 21:48:28 Integrated Voltage Measurement... 21:48:41 Voltage Offset Correction: v_off_ini = -0.000005888 V, v_off_fin = -0.000002126 V 21:48:41 Integrated Voltage Measurement Delta Gap = -0.0020003 m VT = 0.100670755 Vs