SLAC Magnetic Measurements Date: 02-15-2018 Time: 21:24:09 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 110 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=3.5 s Coil attached with tape. Offset corr: TRUE Samples offset corr.: 20 21:24:09 Ambient Measurement Device(s) Being Used, type = None 21:24:09 Magnet Voltage Measurement Device(s) Being Used, type = None 21:24:09 Temperature Measurement Device(s) Being Used, type = None 21:24:09 XMAG Device(s) Being Used, type = None 21:24:09 Ambient Measurement Device(s) Being Used, type = None 21:24:13 Magnet Test Parameter Measurements 21:24:13 Integrated Voltage Measurement... 21:24:28 Voltage Offset Correction: v_off_ini = -0.000006860 V, v_off_fin = -0.000007388 V 21:24:28 Integrated Voltage Measurement Delta Gap = 0.0025001 m VT = -0.121083513 Vs 21:24:28 Integrated Voltage Measurement... 21:24:42 Voltage Offset Correction: v_off_ini = -0.000006737 V, v_off_fin = -0.000003865 V 21:24:43 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122165310 Vs 21:24:45 Magnet Test Parameter Measurements 21:24:45 Integrated Voltage Measurement... 21:24:59 Voltage Offset Correction: v_off_ini = -0.000005162 V, v_off_fin = -0.000004886 V 21:24:59 Integrated Voltage Measurement Delta Gap = 0.0025004 m VT = -0.121100766 Vs 21:24:59 Integrated Voltage Measurement... 21:25:13 Voltage Offset Correction: v_off_ini = -0.000006979 V, v_off_fin = -0.000002444 V 21:25:13 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122143793 Vs 21:25:15 Magnet Test Parameter Measurements 21:25:15 Integrated Voltage Measurement... 21:25:29 Voltage Offset Correction: v_off_ini = -0.000004295 V, v_off_fin = -0.000005399 V 21:25:29 Integrated Voltage Measurement Delta Gap = 0.0025004 m VT = -0.121118831 Vs 21:25:29 Integrated Voltage Measurement... 21:25:43 Voltage Offset Correction: v_off_ini = -0.000005496 V, v_off_fin = -0.000001232 V 21:25:43 Integrated Voltage Measurement Delta Gap = -0.0025004 m VT = 0.122144523 Vs 21:25:46 Magnet Test Parameter Measurements 21:25:46 Integrated Voltage Measurement... 21:26:00 Voltage Offset Correction: v_off_ini = -0.000003990 V, v_off_fin = -0.000006216 V 21:26:00 Integrated Voltage Measurement Delta Gap = 0.0025005 m VT = -0.121099647 Vs 21:26:00 Integrated Voltage Measurement... 21:26:14 Voltage Offset Correction: v_off_ini = -0.000005516 V, v_off_fin = -0.000003464 V 21:26:14 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122167476 Vs 21:26:16 Magnet Test Parameter Measurements 21:26:17 Integrated Voltage Measurement... 21:26:31 Voltage Offset Correction: v_off_ini = -0.000003958 V, v_off_fin = -0.000006489 V 21:26:31 Integrated Voltage Measurement Delta Gap = 0.0025003 m VT = -0.121056661 Vs 21:26:31 Integrated Voltage Measurement... 21:26:46 Voltage Offset Correction: v_off_ini = -0.000004824 V, v_off_fin = -0.000001772 V 21:26:46 Integrated Voltage Measurement Delta Gap = -0.0025002 m VT = 0.122207502 Vs 21:26:48 Magnet Test Parameter Measurements 21:26:49 Integrated Voltage Measurement... 21:27:03 Voltage Offset Correction: v_off_ini = -0.000004151 V, v_off_fin = -0.000004645 V 21:27:03 Integrated Voltage Measurement Delta Gap = 0.0025003 m VT = -0.121101148 Vs 21:27:03 Integrated Voltage Measurement... 21:27:17 Voltage Offset Correction: v_off_ini = -0.000005865 V, v_off_fin = -0.000002819 V 21:27:17 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122176311 Vs 21:27:19 Magnet Test Parameter Measurements 21:27:19 Integrated Voltage Measurement... 21:27:33 Voltage Offset Correction: v_off_ini = -0.000003868 V, v_off_fin = -0.000006336 V 21:27:33 Integrated Voltage Measurement Delta Gap = 0.0025004 m VT = -0.121106715 Vs 21:27:33 Integrated Voltage Measurement... 21:27:47 Voltage Offset Correction: v_off_ini = -0.000006325 V, v_off_fin = -0.000002519 V 21:27:47 Integrated Voltage Measurement Delta Gap = -0.0025004 m VT = 0.122186292 Vs 21:27:50 Magnet Test Parameter Measurements 21:27:50 Integrated Voltage Measurement... 21:28:04 Voltage Offset Correction: v_off_ini = -0.000004668 V, v_off_fin = -0.000005600 V 21:28:04 Integrated Voltage Measurement Delta Gap = 0.0025004 m VT = -0.121074709 Vs 21:28:04 Integrated Voltage Measurement... 21:28:18 Voltage Offset Correction: v_off_ini = -0.000004806 V, v_off_fin = -0.000001882 V 21:28:18 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122151630 Vs 21:28:21 Magnet Test Parameter Measurements 21:28:21 Integrated Voltage Measurement... 21:28:35 Voltage Offset Correction: v_off_ini = -0.000004800 V, v_off_fin = -0.000006217 V 21:28:35 Integrated Voltage Measurement Delta Gap = 0.0025004 m VT = -0.121051934 Vs 21:28:35 Integrated Voltage Measurement... 21:28:49 Voltage Offset Correction: v_off_ini = -0.000005560 V, v_off_fin = -0.000001493 V 21:28:49 Integrated Voltage Measurement Delta Gap = -0.0025003 m VT = 0.122155396 Vs 21:28:52 Magnet Test Parameter Measurements 21:28:52 Integrated Voltage Measurement... 21:29:05 Voltage Offset Correction: v_off_ini = -0.000004522 V, v_off_fin = -0.000005831 V 21:29:06 Integrated Voltage Measurement Delta Gap = 0.0025005 m VT = -0.121114969 Vs 21:29:06 Integrated Voltage Measurement... 21:29:20 Voltage Offset Correction: v_off_ini = -0.000004947 V, v_off_fin = -0.000001943 V 21:29:20 Integrated Voltage Measurement Delta Gap = -0.0025004 m VT = 0.122160616 Vs