SLAC Magnetic Measurements Date: 02-15-2018 Time: 20:40:20 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day8 Serial Number: 00 Run Number: 105 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.25 s ta=4.0 s Coil attached with tape. Offset corr: TRUE Samples offset corr.: 20 20:40:20 Ambient Measurement Device(s) Being Used, type = None 20:40:21 Magnet Voltage Measurement Device(s) Being Used, type = None 20:40:21 Temperature Measurement Device(s) Being Used, type = None 20:40:21 XMAG Device(s) Being Used, type = None 20:40:21 Ambient Measurement Device(s) Being Used, type = None 20:40:24 Magnet Test Parameter Measurements 20:40:24 Integrated Voltage Measurement... 20:40:41 Voltage Offset Correction: v_off_ini = -0.000000846 V, v_off_fin = -0.000007613 V 20:40:41 Integrated Voltage Measurement Delta Gap = 0.0031001 m VT = -0.144064892 Vs 20:40:41 Integrated Voltage Measurement... 20:40:57 Voltage Offset Correction: v_off_ini = -0.000000902 V, v_off_fin = -0.000002888 V 20:40:58 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145222314 Vs 20:41:00 Magnet Test Parameter Measurements 20:41:00 Integrated Voltage Measurement... 20:41:16 Voltage Offset Correction: v_off_ini = 0.000001766 V, v_off_fin = -0.000007104 V 20:41:17 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.144046663 Vs 20:41:17 Integrated Voltage Measurement... 20:41:33 Voltage Offset Correction: v_off_ini = -0.000000014 V, v_off_fin = -0.000003135 V 20:41:33 Integrated Voltage Measurement Delta Gap = -0.0031005 m VT = 0.145224295 Vs 20:41:35 Magnet Test Parameter Measurements 20:41:35 Integrated Voltage Measurement... 20:41:51 Voltage Offset Correction: v_off_ini = 0.000007338 V, v_off_fin = -0.000007521 V 20:41:51 Integrated Voltage Measurement Delta Gap = 0.0031006 m VT = -0.144093645 Vs 20:41:51 Integrated Voltage Measurement... 20:42:08 Voltage Offset Correction: v_off_ini = -0.000001417 V, v_off_fin = -0.000003307 V 20:42:08 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145233562 Vs 20:42:10 Magnet Test Parameter Measurements 20:42:10 Integrated Voltage Measurement... 20:42:27 Voltage Offset Correction: v_off_ini = 0.000000401 V, v_off_fin = -0.000007351 V 20:42:27 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.144010515 Vs 20:42:27 Integrated Voltage Measurement... 20:42:43 Voltage Offset Correction: v_off_ini = -0.000001111 V, v_off_fin = -0.000002167 V 20:42:43 Integrated Voltage Measurement Delta Gap = -0.0031005 m VT = 0.145217691 Vs 20:42:45 Magnet Test Parameter Measurements 20:42:45 Integrated Voltage Measurement... 20:43:02 Voltage Offset Correction: v_off_ini = -0.000000315 V, v_off_fin = -0.000006913 V 20:43:02 Integrated Voltage Measurement Delta Gap = 0.0031006 m VT = -0.144011849 Vs 20:43:02 Integrated Voltage Measurement... 20:43:18 Voltage Offset Correction: v_off_ini = -0.000006208 V, v_off_fin = -0.000002282 V 20:43:19 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145265447 Vs 20:43:21 Magnet Test Parameter Measurements 20:43:21 Integrated Voltage Measurement... 20:43:37 Voltage Offset Correction: v_off_ini = 0.000000862 V, v_off_fin = -0.000007034 V 20:43:37 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.144035542 Vs 20:43:37 Integrated Voltage Measurement... 20:43:54 Voltage Offset Correction: v_off_ini = -0.000005837 V, v_off_fin = -0.000003254 V 20:43:54 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145272519 Vs 20:43:56 Magnet Test Parameter Measurements 20:43:56 Integrated Voltage Measurement... 20:44:13 Voltage Offset Correction: v_off_ini = -0.000003808 V, v_off_fin = -0.000007766 V 20:44:13 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.143993261 Vs 20:44:13 Integrated Voltage Measurement... 20:44:29 Voltage Offset Correction: v_off_ini = -0.000004349 V, v_off_fin = -0.000002067 V 20:44:29 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145238519 Vs 20:44:31 Magnet Test Parameter Measurements 20:44:31 Integrated Voltage Measurement... 20:44:48 Voltage Offset Correction: v_off_ini = -0.000003629 V, v_off_fin = -0.000007199 V 20:44:48 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.144028851 Vs 20:44:48 Integrated Voltage Measurement... 20:45:04 Voltage Offset Correction: v_off_ini = 0.000000434 V, v_off_fin = -0.000002872 V 20:45:04 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145218614 Vs 20:45:06 Magnet Test Parameter Measurements 20:45:06 Integrated Voltage Measurement... 20:45:22 Voltage Offset Correction: v_off_ini = -0.000000875 V, v_off_fin = -0.000006793 V 20:45:22 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.144065379 Vs 20:45:22 Integrated Voltage Measurement... 20:45:39 Voltage Offset Correction: v_off_ini = -0.000005988 V, v_off_fin = -0.000003417 V 20:45:39 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145286287 Vs 20:45:41 Magnet Test Parameter Measurements 20:45:41 Integrated Voltage Measurement... 20:45:58 Voltage Offset Correction: v_off_ini = -0.000000583 V, v_off_fin = -0.000006811 V 20:45:58 Integrated Voltage Measurement Delta Gap = 0.0031005 m VT = -0.143997562 Vs 20:45:58 Integrated Voltage Measurement... 20:46:14 Voltage Offset Correction: v_off_ini = -0.000004587 V, v_off_fin = -0.000003727 V 20:46:14 Integrated Voltage Measurement Delta Gap = -0.0031004 m VT = 0.145267081 Vs