SLAC Magnetic Measurements Date: 02-09-2018 Time: 13:48:34 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day6 Serial Number: 000 Run Number: 63 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.2 s ta=1.3 s Coil attached with tape. Offset corr: TRUE USING THE FILTER SR650 fc=1 Hz, LP 20dB/dec, G=1, Dynamic Reserve Mode 13:48:34 Ambient Measurement Device(s) Being Used, type = None 13:48:34 Magnet Voltage Measurement Device(s) Being Used, type = None 13:48:35 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 13:48:35 XMAG Device(s) Being Used, type = None 13:48:35 Ambient Measurement Device(s) Being Used, type = None 13:48:37 8\ Voltage Measurement, V = 0.000000 V 13:48:37 Temperature Measurement, Probe Number = 0, T = 22.198000 C 13:48:38 Temperature Measurement, Probe Number = 1, T = 22.131000 C 13:48:39 Temperature Measurement, Probe Number = 2, T = 22.206000 C 13:48:39 Temperature Measurement, Probe Number = 3, T = 22.631000 C 13:48:40 Temperature Measurement, Probe Number = 4, T = 22.673000 C 13:48:40 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.20 P2 = Bottom 2, Value = 22.13 P3 = Bottom 3, Value = 22.21 P4 = Top 1, Value = 22.63 P5 = Top 2, Value = 22.67 13:48:40 Integrated Voltage Measurement... 13:49:00 Voltage Offset Correction: v_off_ini = 0.001391122 V, v_off_fin = 0.001368572 V 13:49:00 Integrated Voltage Measurement Delta Gap = 0.0050010 m VT = -0.203040470 Vs 13:49:00 Integrated Voltage Measurement... 13:49:18 Voltage Offset Correction: v_off_ini = 0.001390952 V, v_off_fin = 0.001398625 V 13:49:18 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202886554 Vs 13:49:20 8\ Voltage Measurement, V = 0.000000 V 13:49:21 Temperature Measurement, Probe Number = 0, T = 22.188000 C 13:49:22 Temperature Measurement, Probe Number = 1, T = 22.123000 C 13:49:22 Temperature Measurement, Probe Number = 2, T = 22.193000 C 13:49:23 Temperature Measurement, Probe Number = 3, T = 22.620000 C 13:49:24 Temperature Measurement, Probe Number = 4, T = 22.665000 C 13:49:24 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.19 P2 = Bottom 2, Value = 22.12 P3 = Bottom 3, Value = 22.19 P4 = Top 1, Value = 22.62 P5 = Top 2, Value = 22.66 13:49:24 Integrated Voltage Measurement... 13:49:42 Voltage Offset Correction: v_off_ini = 0.001399069 V, v_off_fin = 0.001376891 V 13:49:42 Integrated Voltage Measurement Delta Gap = 0.0050004 m VT = -0.203064886 Vs 13:49:42 Integrated Voltage Measurement... 13:50:01 Voltage Offset Correction: v_off_ini = 0.001390458 V, v_off_fin = 0.001398316 V 13:50:01 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202950060 Vs 13:50:03 8\ Voltage Measurement, V = 0.000000 V 13:50:04 Temperature Measurement, Probe Number = 0, T = 22.188000 C 13:50:05 Temperature Measurement, Probe Number = 1, T = 22.123000 C 13:50:05 Temperature Measurement, Probe Number = 2, T = 22.196000 C 13:50:06 Temperature Measurement, Probe Number = 3, T = 22.622000 C 13:50:06 Temperature Measurement, Probe Number = 4, T = 22.668000 C 13:50:07 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.19 P2 = Bottom 2, Value = 22.12 P3 = Bottom 3, Value = 22.20 P4 = Top 1, Value = 22.62 P5 = Top 2, Value = 22.67 13:50:07 Integrated Voltage Measurement... 13:50:24 Voltage Offset Correction: v_off_ini = 0.001398817 V, v_off_fin = 0.001378000 V 13:50:25 Integrated Voltage Measurement Delta Gap = 0.0050003 m VT = -0.203050961 Vs 13:50:25 Integrated Voltage Measurement... 13:50:43 Voltage Offset Correction: v_off_ini = 0.001389800 V, v_off_fin = 0.001406687 V 13:50:43 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202982692 Vs 13:50:45 8\ Voltage Measurement, V = 0.000000 V 13:50:46 Temperature Measurement, Probe Number = 0, T = 22.201000 C 13:50:47 Temperature Measurement, Probe Number = 1, T = 22.135000 C 13:50:47 Temperature Measurement, Probe Number = 2, T = 22.206000 C 13:50:48 Temperature Measurement, Probe Number = 3, T = 22.631000 C 13:50:49 Temperature Measurement, Probe Number = 4, T = 22.674000 C 13:50:49 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.20 P2 = Bottom 2, Value = 22.14 P3 = Bottom 3, Value = 22.21 P4 = Top 1, Value = 22.63 P5 = Top 2, Value = 22.67 13:50:49 Integrated Voltage Measurement... 13:51:07 Voltage Offset Correction: v_off_ini = 0.001404624 V, v_off_fin = 0.001377041 V 13:51:07 Integrated Voltage Measurement Delta Gap = 0.0050003 m VT = -0.203011086 Vs 13:51:07 Integrated Voltage Measurement... 13:51:25 Voltage Offset Correction: v_off_ini = 0.001394251 V, v_off_fin = 0.001406626 V 13:51:25 Integrated Voltage Measurement Delta Gap = -0.0050001 m VT = 0.202929020 Vs 13:51:27 8\ Voltage Measurement, V = 0.000000 V 13:51:28 Temperature Measurement, Probe Number = 0, T = 22.217000 C 13:51:29 Temperature Measurement, Probe Number = 1, T = 22.149000 C 13:51:29 Temperature Measurement, Probe Number = 2, T = 22.222000 C 13:51:30 Temperature Measurement, Probe Number = 3, T = 22.644000 C 13:51:30 Temperature Measurement, Probe Number = 4, T = 22.686000 C 13:51:30 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.22 P2 = Bottom 2, Value = 22.15 P3 = Bottom 3, Value = 22.22 P4 = Top 1, Value = 22.64 P5 = Top 2, Value = 22.69 13:51:30 Integrated Voltage Measurement... 13:51:48 Voltage Offset Correction: v_off_ini = 0.001401500 V, v_off_fin = 0.001375998 V 13:51:49 Integrated Voltage Measurement Delta Gap = 0.0050004 m VT = -0.203028421 Vs 13:51:49 Integrated Voltage Measurement... 13:52:07 Voltage Offset Correction: v_off_ini = 0.001390308 V, v_off_fin = 0.001397843 V 13:52:07 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202965362 Vs 13:52:10 8\ Voltage Measurement, V = 0.000000 V 13:52:10 Temperature Measurement, Probe Number = 0, T = 22.232000 C 13:52:11 Temperature Measurement, Probe Number = 1, T = 22.164000 C 13:52:11 Temperature Measurement, Probe Number = 2, T = 22.239000 C 13:52:12 Temperature Measurement, Probe Number = 3, T = 22.657000 C 13:52:13 Temperature Measurement, Probe Number = 4, T = 22.700000 C 13:52:13 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.23 P2 = Bottom 2, Value = 22.16 P3 = Bottom 3, Value = 22.24 P4 = Top 1, Value = 22.66 P5 = Top 2, Value = 22.70 13:52:13 Integrated Voltage Measurement... 13:52:31 Voltage Offset Correction: v_off_ini = 0.001396746 V, v_off_fin = 0.001379799 V 13:52:31 Integrated Voltage Measurement Delta Gap = 0.0050003 m VT = -0.203030005 Vs 13:52:31 Integrated Voltage Measurement... 13:52:49 Voltage Offset Correction: v_off_ini = 0.001392935 V, v_off_fin = 0.001407802 V 13:52:49 Integrated Voltage Measurement Delta Gap = -0.0050001 m VT = 0.202876940 Vs 13:52:51 8\ Voltage Measurement, V = 0.000000 V 13:52:52 Temperature Measurement, Probe Number = 0, T = 22.245000 C 13:52:53 Temperature Measurement, Probe Number = 1, T = 22.174000 C 13:52:53 Temperature Measurement, Probe Number = 2, T = 22.251000 C 13:52:54 Temperature Measurement, Probe Number = 3, T = 22.667000 C 13:52:55 Temperature Measurement, Probe Number = 4, T = 22.711000 C 13:52:55 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.25 P2 = Bottom 2, Value = 22.17 P3 = Bottom 3, Value = 22.25 P4 = Top 1, Value = 22.67 P5 = Top 2, Value = 22.71 13:52:55 Integrated Voltage Measurement... 13:53:13 Voltage Offset Correction: v_off_ini = 0.001405071 V, v_off_fin = 0.001372761 V 13:53:13 Integrated Voltage Measurement Delta Gap = 0.0050004 m VT = -0.203095302 Vs 13:53:13 Integrated Voltage Measurement... 13:53:33 Voltage Offset Correction: v_off_ini = 0.001388580 V, v_off_fin = 0.001401384 V 13:53:33 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202932630 Vs 13:53:35 8\ Voltage Measurement, V = 0.000000 V 13:53:35 Temperature Measurement, Probe Number = 0, T = 22.258000 C 13:53:36 Temperature Measurement, Probe Number = 1, T = 22.187000 C 13:53:37 Temperature Measurement, Probe Number = 2, T = 22.263000 C 13:53:37 Temperature Measurement, Probe Number = 3, T = 22.678000 C 13:53:38 Temperature Measurement, Probe Number = 4, T = 22.721000 C 13:53:38 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.26 P2 = Bottom 2, Value = 22.19 P3 = Bottom 3, Value = 22.26 P4 = Top 1, Value = 22.68 P5 = Top 2, Value = 22.72 13:53:38 Integrated Voltage Measurement... 13:53:56 Voltage Offset Correction: v_off_ini = 0.001400436 V, v_off_fin = 0.001371462 V 13:53:56 Integrated Voltage Measurement Delta Gap = 0.0050003 m VT = -0.203011502 Vs 13:53:56 Integrated Voltage Measurement... 13:54:15 Voltage Offset Correction: v_off_ini = 0.001387530 V, v_off_fin = 0.001408848 V 13:54:15 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202914118 Vs 13:54:17 8\ Voltage Measurement, V = 0.000000 V 13:54:17 Temperature Measurement, Probe Number = 0, T = 22.266000 C 13:54:18 Temperature Measurement, Probe Number = 1, T = 22.196000 C 13:54:19 Temperature Measurement, Probe Number = 2, T = 22.274000 C 13:54:19 Temperature Measurement, Probe Number = 3, T = 22.686000 C 13:54:20 Temperature Measurement, Probe Number = 4, T = 22.730000 C 13:54:20 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.27 P2 = Bottom 2, Value = 22.20 P3 = Bottom 3, Value = 22.27 P4 = Top 1, Value = 22.69 P5 = Top 2, Value = 22.73 13:54:20 Integrated Voltage Measurement... 13:54:39 Voltage Offset Correction: v_off_ini = 0.001399928 V, v_off_fin = 0.001375551 V 13:54:39 Integrated Voltage Measurement Delta Gap = 0.0050005 m VT = -0.203027416 Vs 13:54:39 Integrated Voltage Measurement... 13:54:57 Voltage Offset Correction: v_off_ini = 0.001388142 V, v_off_fin = 0.001401871 V 13:54:57 Integrated Voltage Measurement Delta Gap = -0.0050001 m VT = 0.202896567 Vs 13:54:59 8\ Voltage Measurement, V = 0.000000 V 13:55:00 Temperature Measurement, Probe Number = 0, T = 22.273000 C 13:55:00 Temperature Measurement, Probe Number = 1, T = 22.205000 C 13:55:01 Temperature Measurement, Probe Number = 2, T = 22.284000 C 13:55:02 Temperature Measurement, Probe Number = 3, T = 22.694000 C 13:55:02 Temperature Measurement, Probe Number = 4, T = 22.738000 C 13:55:02 Magnet Test Parameter Measurements P0 = Main (A) , Value = 0.00 P1 = Bottom 1, Value = 22.27 P2 = Bottom 2, Value = 22.20 P3 = Bottom 3, Value = 22.28 P4 = Top 1, Value = 22.69 P5 = Top 2, Value = 22.74 13:55:02 Integrated Voltage Measurement... 13:55:21 Voltage Offset Correction: v_off_ini = 0.001397207 V, v_off_fin = 0.001375001 V 13:55:21 Integrated Voltage Measurement Delta Gap = 0.0050004 m VT = -0.202999504 Vs 13:55:21 Integrated Voltage Measurement... 13:55:39 Voltage Offset Correction: v_off_ini = 0.001390854 V, v_off_fin = 0.001407802 V 13:55:39 Integrated Voltage Measurement Delta Gap = -0.0050002 m VT = 0.202896330 Vs