SLAC Magnetic Measurements Date: 02-03-2018 Time: 16:09:51 Project: LCLS2 Magnet Type: Undulator Magnet Name: SXU_Day2 Serial Number: 000 Run Number: 14 Measurement Device: PXI4464 Operator: jeb Comment: fs=100 Hz tb=0.2 s ta=1.0 s Coil attached with tape. Offset corr: TRUE Undulator Gap Integral vs Gap Change Distance the gap was moved = 0.000400 m Time Gap Start Gap Change Voltage Integral (m) (m) (Vs) ---------- ----------- ------------ ------------------ 16:10:03 0.007200 0.0004004 -0.0199686 16:10:10 0.007600 -0.0004001 0.0201485 16:10:20 0.007200 0.0004002 -0.0199530 16:10:26 0.007600 -0.0004001 0.0201664 16:10:36 0.007200 0.0004002 -0.0199462 16:10:42 0.007600 -0.0004001 0.0201501 16:10:52 0.007200 0.0004002 -0.0199549 16:10:59 0.007600 -0.0004001 0.0201491 16:11:09 0.007200 0.0004002 -0.0199309 16:11:15 0.007600 -0.0004001 0.0201674 16:11:25 0.007200 0.0004002 -0.0199597 16:11:32 0.007600 -0.0004001 0.0201544 16:11:42 0.007200 0.0004002 -0.0199367 16:11:49 0.007600 -0.0004001 0.0201723 16:11:59 0.007200 0.0004001 -0.0199457 16:12:05 0.007600 -0.0004001 0.0201610 16:12:15 0.007200 0.0004001 -0.0199546 16:12:22 0.007600 -0.0004001 0.0201468 16:12:32 0.007200 0.0004001 -0.0199204 16:12:40 0.007600 -0.0004001 0.0201539