SLAC Magnetic Measurements Date: 04-16-2019 Time: 09:22:04 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4573 Serial Number: 101 Run Number: 2 Measurement Device: 10wire Operator: sda Comment: BL vs current at 216.88 with trim at 0 then at 6 amps. Magnet stdz before measurements Standardization for MAIN: 3 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 216.73 216.73 300.00 Test Currents for TRIM (A): 0.00 6.00 0.00 09:22:54 Position moved: 0.000000 m 09:22:58 Magnet Current for MAIN, Imag = -0.0064 A Vtrans = -0.000064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:22:58 Magnet Current for MAIN, Imag = -0.0065 A Vtrans = -0.000065 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:22:59 Magnet Current for MAIN, Imag = -0.0064 A Vtrans = -0.000064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:23:00 Magnet Current for MAIN, Imag = -0.0064 A Vtrans = -0.000064 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 09:23:00 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0064 +- 0.0000 A 09:23:00 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0064202 A 09:23:01 Magnet Current for TRIM, Imag = 0.0011 A Vtrans = 0.000090 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:23:02 Magnet Current for TRIM, Imag = 0.0011 A Vtrans = 0.000090 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:23:03 Magnet Current for TRIM, Imag = 0.0011 A Vtrans = 0.000090 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:23:03 Magnet Current for TRIM, Imag = 0.0011 A Vtrans = 0.000090 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 09:23:03 Magnet Avgerage Current Measurement for TRIM : Imag = 0.0011 +- 0.0000 A 09:25:26 Initial Zero Current Measurement for TRIM, Imag_zero = 0.00108123 A 09:25:26 Ambient Measurement Device(s) Being Used, type = None 09:25:26 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 09:25:27 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 09:25:27 XMAG Device(s) Being Used, type = None 09:25:27 Ambient Measurement Device(s) Being Used, type = HP34970 09:25:27 Magnet system MAIN current ramping to 300.0000 A... 09:26:08 Magnet system MAIN current ramping to 0.0000 A... 09:26:48 Magnet system MAIN current ramping to 300.0000 A... 09:27:29 Magnet system MAIN current ramping to 0.0000 A... 09:28:09 Magnet system MAIN current ramping to 300.0000 A... 09:28:49 Magnet system MAIN current ramping to 0.0000 A... 09:29:33 Position moved: 0.000000 m 09:29:35 Magnet system MAIN current ramping to 216.7300 A... 09:30:07 Magnet system TRIM current ramping to 0.0000 A... 09:30:18 Magnet Current for MAIN, Imag = 216.7614 A Vtrans = 2.167549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:30:19 Magnet Current for TRIM, Imag = 0.0002 A Vtrans = 0.000103 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:30:19 MAIN (V) Voltage Measurement, V = -4.647071 V 09:30:20 Temperature Measurement, Probe Number = 0, T = 22.781000 C 09:30:21 Temperature Measurement, Probe Number = 1, T = 25.590000 C 09:30:22 Temperature Measurement, Probe Number = 2, T = 18.184000 C 09:30:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.296582 V 09:30:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.296582 (V, A, ohm, ...), Measured Value = 28.008079 (C, atm, Hz, ...) 09:30:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.188991 V 09:30:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.188991 (V, A, ohm, ...), Measured Value = 26.513767 (C, atm, Hz, ...) 09:30:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.701595 V 09:30:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.701595 (V, A, ohm, ...), Measured Value = 127.619602 (C, atm, Hz, ...) 09:30:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.129189 V 09:30:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.129189 (V, A, ohm, ...), Measured Value = 9.689153 (C, atm, Hz, ...) 09:30:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.76 P1 = TRIM, Value = 0.00 P2 = MAIN (V), Value = -4.65 P3 = Magnet Core, Value = 22.78 P4 = Coil, Value = 25.59 P5 = Ambient Temp (C), Value = 18.18 P6 = Supply Temp(C), Value = 28.01 P7 = Return Temp(C), Value = 26.51 P8 = Supply Pres(psi), Value = 127.62 P9 = Return Pres(psi), Value = 9.69 09:30:24 Magnetic Field Measurement Measuring the magnet strength... 09:30:24 Integrated Voltage Measurement... 09:30:25 Magnet Current for MAIN, Imag = 216.7600 A Vtrans = 2.167536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:30:26 Magnet Current for TRIM, Imag = 0.0001 A Vtrans = 0.000099 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042733035 Vs 09:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042746541 Vs 09:30:41 Magnet Current for MAIN, Imag = 216.7610 A Vtrans = 2.167546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:30:42 Magnet Current for TRIM, Imag = 0.0004 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:30:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042705137 Vs 09:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042740466 Vs 09:30:56 Magnet Current for MAIN, Imag = 216.7601 A Vtrans = 2.167537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:30:57 Magnet Current for TRIM, Imag = -0.0005 A Vtrans = 0.000052 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042737687 Vs 09:31:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042740626 Vs 09:31:12 Magnet Current for MAIN, Imag = 216.7592 A Vtrans = 2.167528 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:31:12 Magnet Current for TRIM, Imag = -0.0007 A Vtrans = 0.000034 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042752483 Vs 09:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042703435 Vs 09:31:27 Magnet Current for MAIN, Imag = 216.7597 A Vtrans = 2.167533 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:31:28 Magnet Current for TRIM, Imag = -0.0006 A Vtrans = 0.000040 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:31:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042733239 Vs 09:31:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.042747902 Vs 09:31:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.042734055 +- 0.000007282 Vs 09:31:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.042734055 +- 0.000007282 Vs BL = -0.47482283 +- 0.00008091 Tm 09:31:46 Position moved: 0.000000 m 09:31:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.47482 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.47482 0.00008 -0.47482 0.00000 09:31:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.47482 0.00008 SL = -0.4748228 +- 0.0000809 Tm^2/m^n 09:31:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4748228 +- 0.0000809 Tm^2/m^n 09:31:49 Position moved: 0.000000 m 09:31:49 Magnet system MAIN current ramping to 216.7300 A... 09:31:59 Magnet system TRIM current ramping to 6.0000 A... 09:32:16 Magnet Current for MAIN, Imag = 216.7600 A Vtrans = 2.167536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:32:17 Magnet Current for TRIM, Imag = 6.0032 A Vtrans = 0.500355 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:32:17 MAIN (V) Voltage Measurement, V = -4.655569 V 09:32:18 Temperature Measurement, Probe Number = 0, T = 22.786000 C 09:32:19 Temperature Measurement, Probe Number = 1, T = 25.641000 C 09:32:19 Temperature Measurement, Probe Number = 2, T = 18.221000 C 09:32:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.297159 V 09:32:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.297159 (V, A, ohm, ...), Measured Value = 28.016093 (C, atm, Hz, ...) 09:32:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.205704 V 09:32:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.205704 (V, A, ohm, ...), Measured Value = 26.745885 (C, atm, Hz, ...) 09:32:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.605250 V 09:32:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.605250 (V, A, ohm, ...), Measured Value = 120.393735 (C, atm, Hz, ...) 09:32:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.129072 V 09:32:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.129072 (V, A, ohm, ...), Measured Value = 9.680377 (C, atm, Hz, ...) 09:32:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 216.76 P1 = TRIM, Value = 6.00 P2 = MAIN (V), Value = -4.66 P3 = Magnet Core, Value = 22.79 P4 = Coil, Value = 25.64 P5 = Ambient Temp (C), Value = 18.22 P6 = Supply Temp(C), Value = 28.02 P7 = Return Temp(C), Value = 26.75 P8 = Supply Pres(psi), Value = 120.39 P9 = Return Pres(psi), Value = 9.68 09:32:22 Magnetic Field Measurement Measuring the magnet strength... 09:32:22 Integrated Voltage Measurement... 09:32:23 Magnet Current for MAIN, Imag = 216.7604 A Vtrans = 2.167539 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:32:23 Magnet Current for TRIM, Imag = 6.0032 A Vtrans = 0.500356 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:32:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044673073 Vs 09:32:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044676376 Vs 09:32:39 Magnet Current for MAIN, Imag = 216.7604 A Vtrans = 2.167539 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:32:40 Magnet Current for TRIM, Imag = 6.0032 A Vtrans = 0.500353 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:32:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044691048 Vs 09:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044687806 Vs 09:32:54 Magnet Current for MAIN, Imag = 216.7599 A Vtrans = 2.167534 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:32:55 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500352 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:33:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044690909 Vs 09:33:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044635301 Vs 09:33:09 Magnet Current for MAIN, Imag = 216.7597 A Vtrans = 2.167533 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:33:10 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500351 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044656391 Vs 09:33:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044634504 Vs 09:33:25 Magnet Current for MAIN, Imag = 216.7600 A Vtrans = 2.167536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:33:25 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500349 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:33:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044641420 Vs 09:33:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044711312 Vs 09:33:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044669814 +- 0.000014768 Vs 09:33:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.044669814 +- 0.000014768 Vs BL = -0.49633127 +- 0.00016409 Tm 09:33:43 Position moved: 0.000000 m 09:33:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.49633 0.00016 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.49633 0.00016 -0.49633 0.00000 09:33:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.49633 0.00016 SL = -0.4963313 +- 0.0001641 Tm^2/m^n 09:33:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4963313 +- 0.0001641 Tm^2/m^n Remeasure 09:33:43 Magnetic Field Measurement Measuring the magnet strength... 09:33:43 Integrated Voltage Measurement... 09:33:44 Magnet Current for MAIN, Imag = 216.7596 A Vtrans = 2.167532 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:33:45 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500350 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044656617 Vs 09:33:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044656398 Vs 09:34:00 Magnet Current for MAIN, Imag = 216.7591 A Vtrans = 2.167527 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:34:01 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500347 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044656275 Vs 09:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044665756 Vs 09:34:15 Magnet Current for MAIN, Imag = 216.7593 A Vtrans = 2.167529 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:34:16 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500347 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:34:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044678614 Vs 09:34:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044644289 Vs 09:34:31 Magnet Current for MAIN, Imag = 216.7590 A Vtrans = 2.167525 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:34:31 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500348 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044683405 Vs 09:34:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044685131 Vs 09:34:46 Magnet Current for MAIN, Imag = 216.7591 A Vtrans = 2.167527 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:34:47 Magnet Current for TRIM, Imag = 6.0031 A Vtrans = 0.500348 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:34:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044645501 Vs 09:35:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.044699296 Vs 09:35:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.044667128 +- 0.000010039 Vs 09:35:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.044667128 +- 0.000010039 Vs BL = -0.49630143 +- 0.00011155 Tm 09:35:04 Position moved: 0.000000 m 09:35:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.49630 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.49630 0.00011 -0.49630 0.00000 09:35:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.49630 0.00011 SL = -0.4963014 +- 0.0001115 Tm^2/m^n 09:35:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.4963014 +- 0.0001115 Tm^2/m^n 09:35:07 Position moved: 0.000000 m 09:35:07 Magnet system MAIN current ramping to 300.0000 A... 09:35:26 Magnet system TRIM current ramping to 0.0000 A... 09:35:43 Magnet Current for MAIN, Imag = 300.1368 A Vtrans = 3.001303 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006420 A 09:35:44 Magnet Current for TRIM, Imag = 0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001081 A 09:35:44 MAIN (V) Voltage Measurement, V = -6.472764 V 09:35:45 Temperature Measurement, Probe Number = 0, T = 22.810000 C 09:35:45 Temperature Measurement, Probe Number = 1, T = 25.957000 C 09:35:46 Temperature Measurement, Probe Number = 2, T = 18.299000 C 09:35:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.298253 V 09:35:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.298253 (V, A, ohm, ...), Measured Value = 28.031293 (C, atm, Hz, ...) 09:35:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.239940 V 09:35:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.239940 (V, A, ohm, ...), Measured Value = 27.221390 (C, atm, Hz, ...) 09:35:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.743589 V 09:35:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.743589 (V, A, ohm, ...), Measured Value = 130.769160 (C, atm, Hz, ...) 09:35:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.129714 V 09:35:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.129714 (V, A, ohm, ...), Measured Value = 9.728520 (C, atm, Hz, ...) 09:35:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 300.14 P1 = TRIM, Value = 0.00 P2 = MAIN (V), Value = -6.47 P3 = Magnet Core, Value = 22.81 P4 = Coil, Value = 25.96 P5 = Ambient Temp (C), Value = 18.30 P6 = Supply Temp(C), Value = 28.03 P7 = Return Temp(C), Value = 27.22 P8 = Supply Pres(psi), Value = 130.77 P9 = Return Pres(psi), Value = 9.73 09:35:52 Position moved: 0.000000 m 09:35:55 Magnet system MAIN current ramping to 0.0000 A... 09:36:25 Magnet system TRIM current ramping to 0.0000 A...