SLAC Magnetic Measurements Date: 04-16-2019 Time: 15:36:03 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4573 Serial Number: 101 Run Number: 4 Measurement Device: 10wire Operator: sda Comment: BL vs current near 216.88 with trim at +/- 6 amps. Magnet stdz before measurements Standardization for MAIN: 3 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for MAIN (A): 216.82 216.82 216.82 216.82 216.82 300.00 Test Currents for TRIM (A): 0.00 -6.00 0.00 6.00 -6.00 0.00 Integrated Dipole Strength Distance the wire was to be moved = 0.009000 m Number of turns in the wire = 10 Number of measurements for averaging = 5 MAIN +/- sigma TRIM +/- sigma BL sigBL BL/I sigBL/I (A) (A) (A) (A) (Tm) (Tm) (Tm/A) (Tm/A) ------------+---------- ------------+---------- -------------+------------ -------------+------------- 216.9254 0.0001 0.0000 0.0000 0.475300 0.000088 0.002191 0.000000 216.9253 0.0001 0.0000 0.0000 0.475247 0.000037 0.002191 0.000000 216.9260 0.0001 0.0000 0.0000 0.475238 0.000052 0.002191 0.000000 216.9269 0.0001 0.0000 0.0000 0.475223 0.000089 0.002191 0.000000 216.9275 0.0001 0.0000 0.0000 0.475346 0.000072 0.002191 0.000000