SLAC Magnetic Measurements Date: 07-22-2025 Time: 14:53:08 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4565 Serial Number: Run Number: 5 Measurement Device: 10wire Operator: sda Comment: On the Curve step 5. Standardzie then measurement at 87.5 amps and then stdz and measurement at 75 A. Repeat 20 times Standardization for MAIN: 3 cycles from 0.0 A to 125.0 A to 0.0 A Test Currents for MAIN (A): 87.50 75.00 125.00 0.00 125.00 0.00 125.00 0.00 125.00 0.00 75.00 14:53:33 Position moved: 0.000000 m 14:53:40 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:42 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:45 Magnet Current for MAIN, Imag = 0.0000 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:47 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:53:47 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0001 +- 0.0002 A 14:55:28 Initial Zero Current Measurement for MAIN, Imag_zero = -9.75e-05 A 14:55:28 Ambient Measurement Device(s) Being Used, type = None 14:55:29 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 14:55:30 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:55:30 Ambient Measurement Device(s) Being Used, type = HP34970 14:55:30 Magnet system MAIN current ramping to 125.0000 A... 14:56:44 Magnet Current for MAIN, Imag = 124.9876 A Vtrans = 1.249875 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 14:56:46 Main (V) Voltage Measurement, V = 4.458752 V 14:56:54 Temperature Measurement, Probe Number = 0, T = 26.015000 C 14:56:56 Temperature Measurement, Probe Number = 1, T = 27.534000 C 14:56:58 Temperature Measurement, Probe Number = 2, T = 27.889000 C 14:57:00 Temperature Measurement, Probe Number = 3, T = 23.347000 C 14:57:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339278 V 14:57:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339278 (V, A, ohm, ...), Measured Value = 28.601083 (C, atm, Hz, ...) 14:57:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.295262 V 14:57:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.295262 (V, A, ohm, ...), Measured Value = 27.989756 (C, atm, Hz, ...) 14:57:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280748 V 14:57:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280748 (V, A, ohm, ...), Measured Value = 96.056078 (C, atm, Hz, ...) 14:57:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.087065 V 14:57:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.087065 (V, A, ohm, ...), Measured Value = 6.529905 (C, atm, Hz, ...) 14:57:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 14:57:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895743 (C, atm, Hz, ...) 14:57:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.02 P3 = Right Coil Outgoing Side, Value = 27.53 P4 = Left Coil Middle, Value = 27.89 P5 = Ambient, Value = 23.35 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 27.99 P8 = Supply Pres(psi), Value = 96.06 P9 = Return Pres(psi), Value = 6.53 P10 = Flow Rate(gpm), Value = 0.90 14:58:19 Magnet Current for MAIN, Imag = 124.9908 A Vtrans = 1.249907 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 14:58:21 Main (V) Voltage Measurement, V = 4.466686 V 14:58:26 Temperature Measurement, Probe Number = 0, T = 25.960000 C 14:58:29 Temperature Measurement, Probe Number = 1, T = 28.034000 C 14:58:31 Temperature Measurement, Probe Number = 2, T = 28.324000 C 14:58:33 Temperature Measurement, Probe Number = 3, T = 23.354000 C 14:58:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339477 V 14:58:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339477 (V, A, ohm, ...), Measured Value = 28.603847 (C, atm, Hz, ...) 14:58:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.310480 V 14:58:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.310480 (V, A, ohm, ...), Measured Value = 28.201110 (C, atm, Hz, ...) 14:58:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.285560 V 14:58:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.285560 (V, A, ohm, ...), Measured Value = 96.417037 (C, atm, Hz, ...) 14:58:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.087304 V 14:58:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.087304 (V, A, ohm, ...), Measured Value = 6.547823 (C, atm, Hz, ...) 14:58:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 14:58:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893111 (C, atm, Hz, ...) 14:58:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 25.96 P3 = Right Coil Outgoing Side, Value = 28.03 P4 = Left Coil Middle, Value = 28.32 P5 = Ambient, Value = 23.35 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 28.20 P8 = Supply Pres(psi), Value = 96.42 P9 = Return Pres(psi), Value = 6.55 P10 = Flow Rate(gpm), Value = 0.89 14:59:52 Magnet Current for MAIN, Imag = 124.9906 A Vtrans = 1.249905 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 14:59:54 Main (V) Voltage Measurement, V = 4.467637 V 14:59:59 Temperature Measurement, Probe Number = 0, T = 25.967000 C 15:00:01 Temperature Measurement, Probe Number = 1, T = 28.567000 C 15:00:03 Temperature Measurement, Probe Number = 2, T = 28.530000 C 15:00:05 Temperature Measurement, Probe Number = 3, T = 23.382000 C 15:00:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339799 V 15:00:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339799 (V, A, ohm, ...), Measured Value = 28.608314 (C, atm, Hz, ...) 15:00:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.348359 V 15:00:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348359 (V, A, ohm, ...), Measured Value = 28.727203 (C, atm, Hz, ...) 15:00:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280807 V 15:00:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280807 (V, A, ohm, ...), Measured Value = 96.060533 (C, atm, Hz, ...) 15:00:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.087581 V 15:00:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.087581 (V, A, ohm, ...), Measured Value = 6.568560 (C, atm, Hz, ...) 15:00:21 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 15:00:21 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890420 (C, atm, Hz, ...) 15:00:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 25.97 P3 = Right Coil Outgoing Side, Value = 28.57 P4 = Left Coil Middle, Value = 28.53 P5 = Ambient, Value = 23.38 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 28.73 P8 = Supply Pres(psi), Value = 96.06 P9 = Return Pres(psi), Value = 6.57 P10 = Flow Rate(gpm), Value = 0.89 15:01:24 Magnet Current for MAIN, Imag = 124.9902 A Vtrans = 1.249901 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:01:26 Main (V) Voltage Measurement, V = 4.467766 V 15:01:31 Temperature Measurement, Probe Number = 0, T = 25.980000 C 15:01:33 Temperature Measurement, Probe Number = 1, T = 28.763000 C 15:01:35 Temperature Measurement, Probe Number = 2, T = 28.603000 C 15:01:37 Temperature Measurement, Probe Number = 3, T = 23.369000 C 15:01:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340100 V 15:01:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340100 (V, A, ohm, ...), Measured Value = 28.612494 (C, atm, Hz, ...) 15:01:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.379902 V 15:01:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.379902 (V, A, ohm, ...), Measured Value = 29.165300 (C, atm, Hz, ...) 15:01:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275422 V 15:01:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275422 (V, A, ohm, ...), Measured Value = 95.656658 (C, atm, Hz, ...) 15:01:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.087992 V 15:01:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.087992 (V, A, ohm, ...), Measured Value = 6.599362 (C, atm, Hz, ...) 15:01:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 15:01:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910153 (C, atm, Hz, ...) 15:01:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 25.98 P3 = Right Coil Outgoing Side, Value = 28.76 P4 = Left Coil Middle, Value = 28.60 P5 = Ambient, Value = 23.37 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.17 P8 = Supply Pres(psi), Value = 95.66 P9 = Return Pres(psi), Value = 6.60 P10 = Flow Rate(gpm), Value = 0.91 15:02:56 Magnet Current for MAIN, Imag = 124.9910 A Vtrans = 1.249909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:02:58 Main (V) Voltage Measurement, V = 4.467812 V 15:03:03 Temperature Measurement, Probe Number = 0, T = 25.992000 C 15:03:05 Temperature Measurement, Probe Number = 1, T = 28.939000 C 15:03:07 Temperature Measurement, Probe Number = 2, T = 28.624000 C 15:03:10 Temperature Measurement, Probe Number = 3, T = 23.431000 C 15:03:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340271 V 15:03:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340271 (V, A, ohm, ...), Measured Value = 28.614881 (C, atm, Hz, ...) 15:03:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.400934 V 15:03:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.400934 (V, A, ohm, ...), Measured Value = 29.457419 (C, atm, Hz, ...) 15:03:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281489 V 15:03:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281489 (V, A, ohm, ...), Measured Value = 96.111683 (C, atm, Hz, ...) 15:03:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088170 V 15:03:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088170 (V, A, ohm, ...), Measured Value = 6.612735 (C, atm, Hz, ...) 15:03:26 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 15:03:26 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.882819 (C, atm, Hz, ...) 15:03:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 25.99 P3 = Right Coil Outgoing Side, Value = 28.94 P4 = Left Coil Middle, Value = 28.62 P5 = Ambient, Value = 23.43 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.46 P8 = Supply Pres(psi), Value = 96.11 P9 = Return Pres(psi), Value = 6.61 P10 = Flow Rate(gpm), Value = 0.88 15:04:29 Magnet Current for MAIN, Imag = 124.9910 A Vtrans = 1.249909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:04:31 Main (V) Voltage Measurement, V = 4.467983 V 15:04:36 Temperature Measurement, Probe Number = 0, T = 25.993000 C 15:04:38 Temperature Measurement, Probe Number = 1, T = 29.039000 C 15:04:40 Temperature Measurement, Probe Number = 2, T = 28.652000 C 15:04:42 Temperature Measurement, Probe Number = 3, T = 23.445000 C 15:04:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340816 V 15:04:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340816 (V, A, ohm, ...), Measured Value = 28.622450 (C, atm, Hz, ...) 15:04:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.413514 V 15:04:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.413514 (V, A, ohm, ...), Measured Value = 29.632140 (C, atm, Hz, ...) 15:04:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281458 V 15:04:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281458 (V, A, ohm, ...), Measured Value = 96.109358 (C, atm, Hz, ...) 15:04:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088064 V 15:04:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088064 (V, A, ohm, ...), Measured Value = 6.604785 (C, atm, Hz, ...) 15:04:59 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 15:04:59 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895458 (C, atm, Hz, ...) 15:04:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 25.99 P3 = Right Coil Outgoing Side, Value = 29.04 P4 = Left Coil Middle, Value = 28.65 P5 = Ambient, Value = 23.45 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 29.63 P8 = Supply Pres(psi), Value = 96.11 P9 = Return Pres(psi), Value = 6.60 P10 = Flow Rate(gpm), Value = 0.90 15:06:01 Magnet Current for MAIN, Imag = 124.9906 A Vtrans = 1.249905 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:06:03 Main (V) Voltage Measurement, V = 4.467987 V 15:06:09 Temperature Measurement, Probe Number = 0, T = 26.008000 C 15:06:11 Temperature Measurement, Probe Number = 1, T = 29.094000 C 15:06:13 Temperature Measurement, Probe Number = 2, T = 28.632000 C 15:06:15 Temperature Measurement, Probe Number = 3, T = 23.425000 C 15:06:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340698 V 15:06:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340698 (V, A, ohm, ...), Measured Value = 28.620800 (C, atm, Hz, ...) 15:06:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.422108 V 15:06:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.422108 (V, A, ohm, ...), Measured Value = 29.751496 (C, atm, Hz, ...) 15:06:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279801 V 15:06:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279801 (V, A, ohm, ...), Measured Value = 95.985068 (C, atm, Hz, ...) 15:06:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088033 V 15:06:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088033 (V, A, ohm, ...), Measured Value = 6.602460 (C, atm, Hz, ...) 15:06:31 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 15:06:31 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.902631 (C, atm, Hz, ...) 15:06:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.01 P3 = Right Coil Outgoing Side, Value = 29.09 P4 = Left Coil Middle, Value = 28.63 P5 = Ambient, Value = 23.43 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 29.75 P8 = Supply Pres(psi), Value = 95.99 P9 = Return Pres(psi), Value = 6.60 P10 = Flow Rate(gpm), Value = 0.90 15:07:34 Magnet Current for MAIN, Imag = 124.9890 A Vtrans = 1.249889 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:07:36 Main (V) Voltage Measurement, V = 4.467989 V 15:07:41 Temperature Measurement, Probe Number = 0, T = 26.012000 C 15:07:43 Temperature Measurement, Probe Number = 1, T = 29.131000 C 15:07:45 Temperature Measurement, Probe Number = 2, T = 28.601000 C 15:07:47 Temperature Measurement, Probe Number = 3, T = 23.399000 C 15:07:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340196 V 15:07:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340196 (V, A, ohm, ...), Measured Value = 28.613839 (C, atm, Hz, ...) 15:07:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.427149 V 15:07:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.427149 (V, A, ohm, ...), Measured Value = 29.821517 (C, atm, Hz, ...) 15:07:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278056 V 15:07:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278056 (V, A, ohm, ...), Measured Value = 95.854185 (C, atm, Hz, ...) 15:07:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088206 V 15:07:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088206 (V, A, ohm, ...), Measured Value = 6.615442 (C, atm, Hz, ...) 15:08:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 15:08:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888210 (C, atm, Hz, ...) 15:08:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.01 P3 = Right Coil Outgoing Side, Value = 29.13 P4 = Left Coil Middle, Value = 28.60 P5 = Ambient, Value = 23.40 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.82 P8 = Supply Pres(psi), Value = 95.85 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.89 15:09:06 Magnet Current for MAIN, Imag = 124.9907 A Vtrans = 1.249906 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:09:08 Main (V) Voltage Measurement, V = 4.467882 V 15:09:13 Temperature Measurement, Probe Number = 0, T = 26.026000 C 15:09:15 Temperature Measurement, Probe Number = 1, T = 29.051000 C 15:09:17 Temperature Measurement, Probe Number = 2, T = 28.652000 C 15:09:19 Temperature Measurement, Probe Number = 3, T = 23.476000 C 15:09:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339730 V 15:09:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339730 (V, A, ohm, ...), Measured Value = 28.607363 (C, atm, Hz, ...) 15:09:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.430718 V 15:09:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.430718 (V, A, ohm, ...), Measured Value = 29.871085 (C, atm, Hz, ...) 15:09:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275201 V 15:09:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275201 (V, A, ohm, ...), Measured Value = 95.640090 (C, atm, Hz, ...) 15:09:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088017 V 15:09:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088017 (V, A, ohm, ...), Measured Value = 6.601297 (C, atm, Hz, ...) 15:09:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 15:09:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890499 (C, atm, Hz, ...) 15:09:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.03 P3 = Right Coil Outgoing Side, Value = 29.05 P4 = Left Coil Middle, Value = 28.65 P5 = Ambient, Value = 23.48 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.87 P8 = Supply Pres(psi), Value = 95.64 P9 = Return Pres(psi), Value = 6.60 P10 = Flow Rate(gpm), Value = 0.89 15:10:38 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:10:40 Main (V) Voltage Measurement, V = 4.468130 V 15:10:45 Temperature Measurement, Probe Number = 0, T = 26.054000 C 15:10:48 Temperature Measurement, Probe Number = 1, T = 29.032000 C 15:10:50 Temperature Measurement, Probe Number = 2, T = 28.674000 C 15:10:52 Temperature Measurement, Probe Number = 3, T = 23.481000 C 15:10:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339858 V 15:10:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339858 (V, A, ohm, ...), Measured Value = 28.609139 (C, atm, Hz, ...) 15:10:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.433202 V 15:10:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.433202 (V, A, ohm, ...), Measured Value = 29.905585 (C, atm, Hz, ...) 15:10:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274735 V 15:10:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274735 (V, A, ohm, ...), Measured Value = 95.605117 (C, atm, Hz, ...) 15:11:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088055 V 15:11:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088055 (V, A, ohm, ...), Measured Value = 6.604110 (C, atm, Hz, ...) 15:11:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 15:11:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900252 (C, atm, Hz, ...) 15:11:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.05 P3 = Right Coil Outgoing Side, Value = 29.03 P4 = Left Coil Middle, Value = 28.67 P5 = Ambient, Value = 23.48 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.91 P8 = Supply Pres(psi), Value = 95.61 P9 = Return Pres(psi), Value = 6.60 P10 = Flow Rate(gpm), Value = 0.90 15:12:11 Magnet Current for MAIN, Imag = 124.9904 A Vtrans = 1.249903 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:12:13 Main (V) Voltage Measurement, V = 4.467702 V 15:12:18 Temperature Measurement, Probe Number = 0, T = 26.059000 C 15:12:20 Temperature Measurement, Probe Number = 1, T = 29.098000 C 15:12:22 Temperature Measurement, Probe Number = 2, T = 28.683000 C 15:12:24 Temperature Measurement, Probe Number = 3, T = 23.452000 C 15:12:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339251 V 15:12:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339251 (V, A, ohm, ...), Measured Value = 28.600707 (C, atm, Hz, ...) 15:12:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.434969 V 15:12:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.434969 (V, A, ohm, ...), Measured Value = 29.930126 (C, atm, Hz, ...) 15:12:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280430 V 15:12:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280430 (V, A, ohm, ...), Measured Value = 96.032243 (C, atm, Hz, ...) 15:12:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088304 V 15:12:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088304 (V, A, ohm, ...), Measured Value = 6.622807 (C, atm, Hz, ...) 15:12:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 15:12:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892750 (C, atm, Hz, ...) 15:12:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.06 P3 = Right Coil Outgoing Side, Value = 29.10 P4 = Left Coil Middle, Value = 28.68 P5 = Ambient, Value = 23.45 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 29.93 P8 = Supply Pres(psi), Value = 96.03 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.89 15:12:41 Magnet system MAIN current ramping to 0.0000 A... 15:14:03 Magnet system MAIN current ramping to 125.0000 A... 15:15:25 Magnet system MAIN current ramping to 0.0000 A... 15:16:47 Magnet system MAIN current ramping to 125.0000 A... 15:18:09 Magnet system MAIN current ramping to 0.0000 A... 15:19:30 Magnet system MAIN current ramping to 125.0000 A... 15:20:52 Magnet system MAIN current ramping to 0.0000 A... 15:22:18 Position moved: 0.000000 m 15:22:20 Magnet system MAIN current ramping to 87.5000 A... 15:23:23 Magnet Current for MAIN, Imag = 87.4680 A Vtrans = 0.874679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:23:25 Main (V) Voltage Measurement, V = 3.116585 V 15:23:30 Temperature Measurement, Probe Number = 0, T = 26.142000 C 15:23:32 Temperature Measurement, Probe Number = 1, T = 28.191000 C 15:23:34 Temperature Measurement, Probe Number = 2, T = 28.081000 C 15:23:36 Temperature Measurement, Probe Number = 3, T = 23.560000 C 15:23:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342695 V 15:23:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342695 (V, A, ohm, ...), Measured Value = 28.648536 (C, atm, Hz, ...) 15:23:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370839 V 15:23:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370839 (V, A, ohm, ...), Measured Value = 29.039433 (C, atm, Hz, ...) 15:23:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275201 V 15:23:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275201 (V, A, ohm, ...), Measured Value = 95.640090 (C, atm, Hz, ...) 15:23:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088194 V 15:23:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088194 (V, A, ohm, ...), Measured Value = 6.614573 (C, atm, Hz, ...) 15:23:53 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 15:23:53 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878304 (C, atm, Hz, ...) 15:23:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.14 P3 = Right Coil Outgoing Side, Value = 28.19 P4 = Left Coil Middle, Value = 28.08 P5 = Ambient, Value = 23.56 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 95.64 P9 = Return Pres(psi), Value = 6.61 P10 = Flow Rate(gpm), Value = 0.88 15:23:53 Magnetic Field Measurement Measuring the magnet strength... 15:23:53 Integrated Voltage Measurement... 15:23:55 Magnet Current for MAIN, Imag = 87.4683 A Vtrans = 0.874682 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016765147 Vs 15:24:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016756661 Vs 15:24:17 Magnet Current for MAIN, Imag = 87.4681 A Vtrans = 0.874680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:24:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016763313 Vs 15:24:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016757996 Vs 15:24:38 Magnet Current for MAIN, Imag = 87.4678 A Vtrans = 0.874677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016768399 Vs 15:24:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016757325 Vs 15:24:59 Magnet Current for MAIN, Imag = 87.4684 A Vtrans = 0.874683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:25:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016765584 Vs 15:25:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016758176 Vs 15:25:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016761575 +- 0.000000873 Vs 15:25:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016761575 +- 0.000000873 Vs BL = -0.18623972 +- 0.00000970 Tm 15:25:21 Position moved: 0.000000 m 15:25:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18624 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18624 0.00001 -0.18624 0.00000 15:25:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18624 0.00001 SL = -0.1862397 +- 0.0000097 Tm^2/m^n 15:25:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1862397 +- 0.0000097 Tm^2/m^n 15:25:24 Position moved: 0.000000 m 15:25:24 Magnet system MAIN current ramping to 75.0000 A... 15:25:44 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:25:46 Main (V) Voltage Measurement, V = 2.674950 V 15:25:51 Temperature Measurement, Probe Number = 0, T = 26.146000 C 15:25:53 Temperature Measurement, Probe Number = 1, T = 28.227000 C 15:25:55 Temperature Measurement, Probe Number = 2, T = 28.251000 C 15:25:58 Temperature Measurement, Probe Number = 3, T = 23.574000 C 15:26:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342607 V 15:26:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342607 (V, A, ohm, ...), Measured Value = 28.647315 (C, atm, Hz, ...) 15:26:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361601 V 15:26:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361601 (V, A, ohm, ...), Measured Value = 28.911125 (C, atm, Hz, ...) 15:26:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284833 V 15:26:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284833 (V, A, ohm, ...), Measured Value = 96.362497 (C, atm, Hz, ...) 15:26:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088307 V 15:26:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088307 (V, A, ohm, ...), Measured Value = 6.623002 (C, atm, Hz, ...) 15:26:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 15:26:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890477 (C, atm, Hz, ...) 15:26:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.15 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.25 P5 = Ambient, Value = 23.57 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 28.91 P8 = Supply Pres(psi), Value = 96.36 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.89 15:26:14 Magnet system MAIN current ramping to 125.0000 A... 15:26:55 Magnet Current for MAIN, Imag = 124.9919 A Vtrans = 1.249918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:26:58 Main (V) Voltage Measurement, V = 4.461012 V 15:27:03 Temperature Measurement, Probe Number = 0, T = 26.156000 C 15:27:05 Temperature Measurement, Probe Number = 1, T = 28.283000 C 15:27:07 Temperature Measurement, Probe Number = 2, T = 28.304000 C 15:27:09 Temperature Measurement, Probe Number = 3, T = 23.580000 C 15:27:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342662 V 15:27:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342662 (V, A, ohm, ...), Measured Value = 28.648087 (C, atm, Hz, ...) 15:27:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363234 V 15:27:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363234 (V, A, ohm, ...), Measured Value = 28.933801 (C, atm, Hz, ...) 15:27:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282303 V 15:27:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282303 (V, A, ohm, ...), Measured Value = 96.172717 (C, atm, Hz, ...) 15:27:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088190 V 15:27:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088190 (V, A, ohm, ...), Measured Value = 6.614280 (C, atm, Hz, ...) 15:27:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 15:27:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893226 (C, atm, Hz, ...) 15:27:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.16 P3 = Right Coil Outgoing Side, Value = 28.28 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.58 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 28.93 P8 = Supply Pres(psi), Value = 96.17 P9 = Return Pres(psi), Value = 6.61 P10 = Flow Rate(gpm), Value = 0.89 15:27:25 Magnet system MAIN current ramping to 0.0000 A... 15:28:50 Magnet Current for MAIN, Imag = -0.0007 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:28:52 Main (V) Voltage Measurement, V = 0.000003 V 15:28:57 Temperature Measurement, Probe Number = 0, T = 26.175000 C 15:28:59 Temperature Measurement, Probe Number = 1, T = 28.401000 C 15:29:01 Temperature Measurement, Probe Number = 2, T = 28.338000 C 15:29:03 Temperature Measurement, Probe Number = 3, T = 23.604000 C 15:29:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342625 V 15:29:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342625 (V, A, ohm, ...), Measured Value = 28.647567 (C, atm, Hz, ...) 15:29:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372153 V 15:29:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372153 (V, A, ohm, ...), Measured Value = 29.057678 (C, atm, Hz, ...) 15:29:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282547 V 15:29:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282547 (V, A, ohm, ...), Measured Value = 96.191025 (C, atm, Hz, ...) 15:29:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088281 V 15:29:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088281 (V, A, ohm, ...), Measured Value = 6.621060 (C, atm, Hz, ...) 15:29:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 15:29:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.897159 (C, atm, Hz, ...) 15:29:20 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.18 P3 = Right Coil Outgoing Side, Value = 28.40 P4 = Left Coil Middle, Value = 28.34 P5 = Ambient, Value = 23.60 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.06 P8 = Supply Pres(psi), Value = 96.19 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.90 15:29:20 Magnet system MAIN current ramping to 125.0000 A... 15:30:44 Magnet Current for MAIN, Imag = 124.9913 A Vtrans = 1.249912 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:30:46 Main (V) Voltage Measurement, V = 4.461591 V 15:30:51 Temperature Measurement, Probe Number = 0, T = 26.180000 C 15:30:53 Temperature Measurement, Probe Number = 1, T = 28.199000 C 15:30:55 Temperature Measurement, Probe Number = 2, T = 28.266000 C 15:30:57 Temperature Measurement, Probe Number = 3, T = 23.617000 C 15:30:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342872 V 15:30:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342872 (V, A, ohm, ...), Measured Value = 28.650993 (C, atm, Hz, ...) 15:31:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369409 V 15:31:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369409 (V, A, ohm, ...), Measured Value = 29.019574 (C, atm, Hz, ...) 15:31:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280027 V 15:31:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280027 (V, A, ohm, ...), Measured Value = 96.002018 (C, atm, Hz, ...) 15:31:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088402 V 15:31:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088402 (V, A, ohm, ...), Measured Value = 6.630173 (C, atm, Hz, ...) 15:31:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 15:31:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905385 (C, atm, Hz, ...) 15:31:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.18 P3 = Right Coil Outgoing Side, Value = 28.20 P4 = Left Coil Middle, Value = 28.27 P5 = Ambient, Value = 23.62 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 96.00 P9 = Return Pres(psi), Value = 6.63 P10 = Flow Rate(gpm), Value = 0.91 15:31:14 Magnet system MAIN current ramping to 0.0000 A... 15:32:38 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:32:40 Main (V) Voltage Measurement, V = 0.000000 V 15:32:45 Temperature Measurement, Probe Number = 0, T = 26.187000 C 15:32:47 Temperature Measurement, Probe Number = 1, T = 28.418000 C 15:32:50 Temperature Measurement, Probe Number = 2, T = 28.331000 C 15:32:52 Temperature Measurement, Probe Number = 3, T = 23.653000 C 15:32:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343095 V 15:32:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343095 (V, A, ohm, ...), Measured Value = 28.654097 (C, atm, Hz, ...) 15:32:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370733 V 15:32:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370733 (V, A, ohm, ...), Measured Value = 29.037961 (C, atm, Hz, ...) 15:32:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284916 V 15:32:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284916 (V, A, ohm, ...), Measured Value = 96.368700 (C, atm, Hz, ...) 15:33:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088290 V 15:33:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088290 (V, A, ohm, ...), Measured Value = 6.621742 (C, atm, Hz, ...) 15:33:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 15:33:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.898131 (C, atm, Hz, ...) 15:33:08 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.19 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.33 P5 = Ambient, Value = 23.65 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 96.37 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.90 15:33:08 Magnet system MAIN current ramping to 125.0000 A... 15:34:32 Magnet Current for MAIN, Imag = 124.9916 A Vtrans = 1.249915 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:34:34 Main (V) Voltage Measurement, V = 4.461823 V 15:34:39 Temperature Measurement, Probe Number = 0, T = 26.195000 C 15:34:41 Temperature Measurement, Probe Number = 1, T = 28.213000 C 15:34:43 Temperature Measurement, Probe Number = 2, T = 28.217000 C 15:34:46 Temperature Measurement, Probe Number = 3, T = 23.641000 C 15:34:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343613 V 15:34:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343613 (V, A, ohm, ...), Measured Value = 28.661292 (C, atm, Hz, ...) 15:34:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369213 V 15:34:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369213 (V, A, ohm, ...), Measured Value = 29.016846 (C, atm, Hz, ...) 15:34:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278380 V 15:34:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278380 (V, A, ohm, ...), Measured Value = 95.878500 (C, atm, Hz, ...) 15:34:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088260 V 15:34:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088260 (V, A, ohm, ...), Measured Value = 6.619515 (C, atm, Hz, ...) 15:35:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 15:35:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.896866 (C, atm, Hz, ...) 15:35:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.20 P3 = Right Coil Outgoing Side, Value = 28.21 P4 = Left Coil Middle, Value = 28.22 P5 = Ambient, Value = 23.64 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 95.88 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.90 15:35:02 Magnet system MAIN current ramping to 0.0000 A... 15:36:26 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:36:28 Main (V) Voltage Measurement, V = -0.000004 V 15:36:33 Temperature Measurement, Probe Number = 0, T = 26.216000 C 15:36:35 Temperature Measurement, Probe Number = 1, T = 28.410000 C 15:36:37 Temperature Measurement, Probe Number = 2, T = 28.304000 C 15:36:39 Temperature Measurement, Probe Number = 3, T = 23.636000 C 15:36:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343570 V 15:36:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343570 (V, A, ohm, ...), Measured Value = 28.660699 (C, atm, Hz, ...) 15:36:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370728 V 15:36:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370728 (V, A, ohm, ...), Measured Value = 29.037890 (C, atm, Hz, ...) 15:36:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282666 V 15:36:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282666 (V, A, ohm, ...), Measured Value = 96.199935 (C, atm, Hz, ...) 15:36:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088330 V 15:36:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088330 (V, A, ohm, ...), Measured Value = 6.624742 (C, atm, Hz, ...) 15:36:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 15:36:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890492 (C, atm, Hz, ...) 15:36:56 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.64 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 96.20 P9 = Return Pres(psi), Value = 6.62 P10 = Flow Rate(gpm), Value = 0.89 15:36:56 Magnet system MAIN current ramping to 125.0000 A... 15:38:20 Magnet Current for MAIN, Imag = 124.9907 A Vtrans = 1.249906 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:38:22 Main (V) Voltage Measurement, V = 4.461949 V 15:38:27 Temperature Measurement, Probe Number = 0, T = 26.219000 C 15:38:29 Temperature Measurement, Probe Number = 1, T = 28.222000 C 15:38:31 Temperature Measurement, Probe Number = 2, T = 28.234000 C 15:38:33 Temperature Measurement, Probe Number = 3, T = 23.652000 C 15:38:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343119 V 15:38:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343119 (V, A, ohm, ...), Measured Value = 28.654437 (C, atm, Hz, ...) 15:38:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369095 V 15:38:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369095 (V, A, ohm, ...), Measured Value = 29.015214 (C, atm, Hz, ...) 15:38:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272864 V 15:38:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272864 (V, A, ohm, ...), Measured Value = 95.464837 (C, atm, Hz, ...) 15:38:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088436 V 15:38:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088436 (V, A, ohm, ...), Measured Value = 6.632692 (C, atm, Hz, ...) 15:38:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 15:38:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887917 (C, atm, Hz, ...) 15:38:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 28.23 P5 = Ambient, Value = 23.65 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 95.46 P9 = Return Pres(psi), Value = 6.63 P10 = Flow Rate(gpm), Value = 0.89 15:38:50 Magnet system MAIN current ramping to 0.0000 A... 15:40:14 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:40:16 Main (V) Voltage Measurement, V = 0.000001 V 15:40:21 Temperature Measurement, Probe Number = 0, T = 26.235000 C 15:40:23 Temperature Measurement, Probe Number = 1, T = 28.416000 C 15:40:25 Temperature Measurement, Probe Number = 2, T = 28.316000 C 15:40:27 Temperature Measurement, Probe Number = 3, T = 23.635000 C 15:40:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343582 V 15:40:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343582 (V, A, ohm, ...), Measured Value = 28.660861 (C, atm, Hz, ...) 15:40:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371039 V 15:40:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371039 (V, A, ohm, ...), Measured Value = 29.042214 (C, atm, Hz, ...) 15:40:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.285064 V 15:40:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.285064 (V, A, ohm, ...), Measured Value = 96.379837 (C, atm, Hz, ...) 15:40:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088448 V 15:40:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088448 (V, A, ohm, ...), Measured Value = 6.633563 (C, atm, Hz, ...) 15:40:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 15:40:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893229 (C, atm, Hz, ...) 15:40:44 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.23 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.32 P5 = Ambient, Value = 23.64 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 96.38 P9 = Return Pres(psi), Value = 6.63 P10 = Flow Rate(gpm), Value = 0.89 15:40:44 Magnet system MAIN current ramping to 75.0000 A... 15:41:39 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:41:41 Main (V) Voltage Measurement, V = 2.672010 V 15:41:46 Temperature Measurement, Probe Number = 0, T = 26.241000 C 15:41:48 Temperature Measurement, Probe Number = 1, T = 28.185000 C 15:41:50 Temperature Measurement, Probe Number = 2, T = 28.142000 C 15:41:53 Temperature Measurement, Probe Number = 3, T = 23.652000 C 15:41:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343555 V 15:41:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343555 (V, A, ohm, ...), Measured Value = 28.660483 (C, atm, Hz, ...) 15:41:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.373463 V 15:41:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373463 (V, A, ohm, ...), Measured Value = 29.075869 (C, atm, Hz, ...) 15:41:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276099 V 15:41:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276099 (V, A, ohm, ...), Measured Value = 95.707418 (C, atm, Hz, ...) 15:42:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088593 V 15:42:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088593 (V, A, ohm, ...), Measured Value = 6.644505 (C, atm, Hz, ...) 15:42:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 15:42:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897889 (C, atm, Hz, ...) 15:42:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.24 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.14 P5 = Ambient, Value = 23.65 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.08 P8 = Supply Pres(psi), Value = 95.71 P9 = Return Pres(psi), Value = 6.64 P10 = Flow Rate(gpm), Value = 0.90 15:42:09 Magnetic Field Measurement Measuring the magnet strength... 15:42:09 Integrated Voltage Measurement... 15:42:11 Magnet Current for MAIN, Imag = 75.0212 A Vtrans = 0.750211 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:42:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014395364 Vs 15:42:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014386788 Vs 15:42:33 Magnet Current for MAIN, Imag = 75.0213 A Vtrans = 0.750212 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:42:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397682 Vs 15:42:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014387807 Vs 15:42:54 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:43:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014395506 Vs 15:43:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014387315 Vs 15:43:15 Magnet Current for MAIN, Imag = 75.0215 A Vtrans = 0.750215 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:43:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397670 Vs 15:43:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014387775 Vs 15:43:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014391988 +- 0.000000755 Vs 15:43:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014391988 +- 0.000000755 Vs BL = -0.15991098 +- 0.00000838 Tm 15:43:38 Position moved: 0.000000 m 15:43:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15991 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15991 0.00001 -0.15991 0.00000 15:43:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15991 0.00001 SL = -0.1599110 +- 0.0000084 Tm^2/m^n 15:43:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599110 +- 0.0000084 Tm^2/m^n 15:43:41 Position moved: 0.000000 m 15:43:41 Magnet system MAIN current ramping to 125.0000 A... 15:44:20 Magnet system MAIN current ramping to 0.0000 A... 15:45:42 Magnet system MAIN current ramping to 125.0000 A... 15:47:03 Magnet system MAIN current ramping to 0.0000 A... 15:48:25 Magnet system MAIN current ramping to 125.0000 A... 15:49:46 Magnet system MAIN current ramping to 0.0000 A... 15:51:11 Position moved: 0.000000 m 15:51:14 Magnet system MAIN current ramping to 87.5000 A... 15:52:16 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:52:18 Main (V) Voltage Measurement, V = 3.116518 V 15:52:23 Temperature Measurement, Probe Number = 0, T = 26.292000 C 15:52:25 Temperature Measurement, Probe Number = 1, T = 28.183000 C 15:52:27 Temperature Measurement, Probe Number = 2, T = 28.151000 C 15:52:29 Temperature Measurement, Probe Number = 3, T = 23.697000 C 15:52:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341351 V 15:52:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341351 (V, A, ohm, ...), Measured Value = 28.629878 (C, atm, Hz, ...) 15:52:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366462 V 15:52:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366462 (V, A, ohm, ...), Measured Value = 28.978633 (C, atm, Hz, ...) 15:52:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283157 V 15:52:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283157 (V, A, ohm, ...), Measured Value = 96.236753 (C, atm, Hz, ...) 15:52:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088769 V 15:52:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088769 (V, A, ohm, ...), Measured Value = 6.657682 (C, atm, Hz, ...) 15:52:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 15:52:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893132 (C, atm, Hz, ...) 15:52:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.29 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.15 P5 = Ambient, Value = 23.70 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 28.98 P8 = Supply Pres(psi), Value = 96.24 P9 = Return Pres(psi), Value = 6.66 P10 = Flow Rate(gpm), Value = 0.89 15:52:46 Magnetic Field Measurement Measuring the magnet strength... 15:52:46 Integrated Voltage Measurement... 15:52:48 Magnet Current for MAIN, Imag = 87.4684 A Vtrans = 0.874683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:52:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016767191 Vs 15:53:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016761019 Vs 15:53:10 Magnet Current for MAIN, Imag = 87.4688 A Vtrans = 0.874687 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:53:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016768955 Vs 15:53:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016761806 Vs 15:53:31 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:53:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016767246 Vs 15:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016760638 Vs 15:53:51 Magnet Current for MAIN, Imag = 87.4685 A Vtrans = 0.874684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:54:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016766351 Vs 15:54:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016761744 Vs 15:54:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016764369 +- 0.000000587 Vs 15:54:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016764369 +- 0.000000587 Vs BL = -0.18627077 +- 0.00000652 Tm 15:54:14 Position moved: 0.000000 m 15:54:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18627 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18627 0.00001 -0.18627 0.00000 15:54:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18627 0.00001 SL = -0.1862708 +- 0.0000065 Tm^2/m^n 15:54:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1862708 +- 0.0000065 Tm^2/m^n 15:54:17 Position moved: 0.000000 m 15:54:17 Magnet system MAIN current ramping to 75.0000 A... 15:54:37 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:54:40 Main (V) Voltage Measurement, V = 2.674828 V 15:54:45 Temperature Measurement, Probe Number = 0, T = 26.295000 C 15:54:47 Temperature Measurement, Probe Number = 1, T = 28.249000 C 15:54:49 Temperature Measurement, Probe Number = 2, T = 28.277000 C 15:54:51 Temperature Measurement, Probe Number = 3, T = 23.663000 C 15:54:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341358 V 15:54:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341358 (V, A, ohm, ...), Measured Value = 28.629968 (C, atm, Hz, ...) 15:54:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359754 V 15:54:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359754 (V, A, ohm, ...), Measured Value = 28.885471 (C, atm, Hz, ...) 15:54:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.288261 V 15:54:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.288261 (V, A, ohm, ...), Measured Value = 96.619605 (C, atm, Hz, ...) 15:55:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088618 V 15:55:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088618 (V, A, ohm, ...), Measured Value = 6.646350 (C, atm, Hz, ...) 15:55:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 15:55:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890856 (C, atm, Hz, ...) 15:55:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.30 P3 = Right Coil Outgoing Side, Value = 28.25 P4 = Left Coil Middle, Value = 28.28 P5 = Ambient, Value = 23.66 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 96.62 P9 = Return Pres(psi), Value = 6.65 P10 = Flow Rate(gpm), Value = 0.89 15:55:07 Magnet system MAIN current ramping to 125.0000 A... 15:55:49 Magnet Current for MAIN, Imag = 124.9921 A Vtrans = 1.249920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:55:51 Main (V) Voltage Measurement, V = 4.460795 V 15:55:56 Temperature Measurement, Probe Number = 0, T = 26.303000 C 15:55:58 Temperature Measurement, Probe Number = 1, T = 28.314000 C 15:56:00 Temperature Measurement, Probe Number = 2, T = 28.298000 C 15:56:02 Temperature Measurement, Probe Number = 3, T = 23.684000 C 15:56:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341301 V 15:56:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341301 (V, A, ohm, ...), Measured Value = 28.629178 (C, atm, Hz, ...) 15:56:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362164 V 15:56:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362164 (V, A, ohm, ...), Measured Value = 28.918947 (C, atm, Hz, ...) 15:56:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278939 V 15:56:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278939 (V, A, ohm, ...), Measured Value = 95.920447 (C, atm, Hz, ...) 15:56:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088670 V 15:56:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088670 (V, A, ohm, ...), Measured Value = 6.650220 (C, atm, Hz, ...) 15:56:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 15:56:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905332 (C, atm, Hz, ...) 15:56:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.30 P3 = Right Coil Outgoing Side, Value = 28.31 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.68 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.92 P9 = Return Pres(psi), Value = 6.65 P10 = Flow Rate(gpm), Value = 0.91 15:56:19 Magnet system MAIN current ramping to 0.0000 A... 15:57:42 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:57:44 Main (V) Voltage Measurement, V = -0.000001 V 15:57:49 Temperature Measurement, Probe Number = 0, T = 26.311000 C 15:57:52 Temperature Measurement, Probe Number = 1, T = 28.406000 C 15:57:54 Temperature Measurement, Probe Number = 2, T = 28.296000 C 15:57:56 Temperature Measurement, Probe Number = 3, T = 23.685000 C 15:57:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341373 V 15:57:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341373 (V, A, ohm, ...), Measured Value = 28.630183 (C, atm, Hz, ...) 15:58:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371033 V 15:58:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371033 (V, A, ohm, ...), Measured Value = 29.042124 (C, atm, Hz, ...) 15:58:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280150 V 15:58:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280150 (V, A, ohm, ...), Measured Value = 96.011220 (C, atm, Hz, ...) 15:58:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088750 V 15:58:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088750 (V, A, ohm, ...), Measured Value = 6.656227 (C, atm, Hz, ...) 15:58:12 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 15:58:12 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890810 (C, atm, Hz, ...) 15:58:12 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.31 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.68 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 96.01 P9 = Return Pres(psi), Value = 6.66 P10 = Flow Rate(gpm), Value = 0.89 15:58:12 Magnet system MAIN current ramping to 125.0000 A... 15:59:36 Magnet Current for MAIN, Imag = 124.9922 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 15:59:39 Main (V) Voltage Measurement, V = 4.461310 V 15:59:44 Temperature Measurement, Probe Number = 0, T = 26.318000 C 15:59:46 Temperature Measurement, Probe Number = 1, T = 28.228000 C 15:59:48 Temperature Measurement, Probe Number = 2, T = 28.204000 C 15:59:50 Temperature Measurement, Probe Number = 3, T = 23.693000 C 15:59:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341221 V 15:59:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341221 (V, A, ohm, ...), Measured Value = 28.628065 (C, atm, Hz, ...) 15:59:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368371 V 15:59:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368371 (V, A, ohm, ...), Measured Value = 29.005149 (C, atm, Hz, ...) 15:59:56 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278886 V 15:59:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278886 (V, A, ohm, ...), Measured Value = 95.916480 (C, atm, Hz, ...) 15:59:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088884 V 15:59:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088884 (V, A, ohm, ...), Measured Value = 6.666308 (C, atm, Hz, ...) 16:00:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 16:00:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907660 (C, atm, Hz, ...) 16:00:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.32 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.20 P5 = Ambient, Value = 23.69 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 95.92 P9 = Return Pres(psi), Value = 6.67 P10 = Flow Rate(gpm), Value = 0.91 16:00:06 Magnet system MAIN current ramping to 0.0000 A... 16:01:31 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:01:33 Main (V) Voltage Measurement, V = -0.000005 V 16:01:38 Temperature Measurement, Probe Number = 0, T = 26.327000 C 16:01:40 Temperature Measurement, Probe Number = 1, T = 28.426000 C 16:01:42 Temperature Measurement, Probe Number = 2, T = 28.300000 C 16:01:44 Temperature Measurement, Probe Number = 3, T = 23.706000 C 16:01:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341526 V 16:01:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341526 (V, A, ohm, ...), Measured Value = 28.632300 (C, atm, Hz, ...) 16:01:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369577 V 16:01:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369577 (V, A, ohm, ...), Measured Value = 29.021906 (C, atm, Hz, ...) 16:01:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279429 V 16:01:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279429 (V, A, ohm, ...), Measured Value = 95.957168 (C, atm, Hz, ...) 16:01:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088910 V 16:01:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088910 (V, A, ohm, ...), Measured Value = 6.668242 (C, atm, Hz, ...) 16:02:01 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 16:02:01 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.902730 (C, atm, Hz, ...) 16:02:01 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.33 P3 = Right Coil Outgoing Side, Value = 28.43 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.71 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 95.96 P9 = Return Pres(psi), Value = 6.67 P10 = Flow Rate(gpm), Value = 0.90 16:02:01 Magnet system MAIN current ramping to 125.0000 A... 16:03:25 Magnet Current for MAIN, Imag = 124.9921 A Vtrans = 1.249920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:03:28 Main (V) Voltage Measurement, V = 4.462044 V 16:03:33 Temperature Measurement, Probe Number = 0, T = 26.340000 C 16:03:35 Temperature Measurement, Probe Number = 1, T = 28.233000 C 16:03:37 Temperature Measurement, Probe Number = 2, T = 28.223000 C 16:03:39 Temperature Measurement, Probe Number = 3, T = 23.714000 C 16:03:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341860 V 16:03:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341860 (V, A, ohm, ...), Measured Value = 28.636946 (C, atm, Hz, ...) 16:03:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367956 V 16:03:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367956 (V, A, ohm, ...), Measured Value = 28.999390 (C, atm, Hz, ...) 16:03:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281716 V 16:03:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281716 (V, A, ohm, ...), Measured Value = 96.128730 (C, atm, Hz, ...) 16:03:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089105 V 16:03:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089105 (V, A, ohm, ...), Measured Value = 6.682867 (C, atm, Hz, ...) 16:03:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 16:03:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907709 (C, atm, Hz, ...) 16:03:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.34 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.22 P5 = Ambient, Value = 23.71 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.00 P8 = Supply Pres(psi), Value = 96.13 P9 = Return Pres(psi), Value = 6.68 P10 = Flow Rate(gpm), Value = 0.91 16:03:55 Magnet system MAIN current ramping to 0.0000 A... 16:05:19 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:05:22 Main (V) Voltage Measurement, V = -0.000004 V 16:05:27 Temperature Measurement, Probe Number = 0, T = 26.341000 C 16:05:29 Temperature Measurement, Probe Number = 1, T = 28.429000 C 16:05:31 Temperature Measurement, Probe Number = 2, T = 28.310000 C 16:05:33 Temperature Measurement, Probe Number = 3, T = 23.719000 C 16:05:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342262 V 16:05:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342262 (V, A, ohm, ...), Measured Value = 28.642525 (C, atm, Hz, ...) 16:05:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370006 V 16:05:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370006 (V, A, ohm, ...), Measured Value = 29.027861 (C, atm, Hz, ...) 16:05:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283943 V 16:05:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283943 (V, A, ohm, ...), Measured Value = 96.295747 (C, atm, Hz, ...) 16:05:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089048 V 16:05:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089048 (V, A, ohm, ...), Measured Value = 6.678608 (C, atm, Hz, ...) 16:05:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 16:05:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895412 (C, atm, Hz, ...) 16:05:49 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.34 P3 = Right Coil Outgoing Side, Value = 28.43 P4 = Left Coil Middle, Value = 28.31 P5 = Ambient, Value = 23.72 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 96.30 P9 = Return Pres(psi), Value = 6.68 P10 = Flow Rate(gpm), Value = 0.90 16:05:49 Magnet system MAIN current ramping to 125.0000 A... 16:07:13 Magnet Current for MAIN, Imag = 124.9920 A Vtrans = 1.249919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:07:15 Main (V) Voltage Measurement, V = 4.461632 V 16:07:21 Temperature Measurement, Probe Number = 0, T = 26.346000 C 16:07:23 Temperature Measurement, Probe Number = 1, T = 28.219000 C 16:07:25 Temperature Measurement, Probe Number = 2, T = 28.230000 C 16:07:27 Temperature Measurement, Probe Number = 3, T = 23.734000 C 16:07:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342233 V 16:07:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342233 (V, A, ohm, ...), Measured Value = 28.642131 (C, atm, Hz, ...) 16:07:31 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368771 V 16:07:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368771 (V, A, ohm, ...), Measured Value = 29.010711 (C, atm, Hz, ...) 16:07:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.289172 V 16:07:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.289172 (V, A, ohm, ...), Measured Value = 96.687908 (C, atm, Hz, ...) 16:07:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088968 V 16:07:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088968 (V, A, ohm, ...), Measured Value = 6.672600 (C, atm, Hz, ...) 16:07:43 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 16:07:43 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.913022 (C, atm, Hz, ...) 16:07:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.35 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 28.23 P5 = Ambient, Value = 23.73 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 96.69 P9 = Return Pres(psi), Value = 6.67 P10 = Flow Rate(gpm), Value = 0.91 16:07:43 Magnet system MAIN current ramping to 0.0000 A... 16:09:07 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:09:09 Main (V) Voltage Measurement, V = 0.000001 V 16:09:15 Temperature Measurement, Probe Number = 0, T = 26.359000 C 16:09:17 Temperature Measurement, Probe Number = 1, T = 28.422000 C 16:09:19 Temperature Measurement, Probe Number = 2, T = 28.306000 C 16:09:21 Temperature Measurement, Probe Number = 3, T = 23.726000 C 16:09:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341941 V 16:09:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341941 (V, A, ohm, ...), Measured Value = 28.638076 (C, atm, Hz, ...) 16:09:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370882 V 16:09:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370882 (V, A, ohm, ...), Measured Value = 29.040025 (C, atm, Hz, ...) 16:09:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275332 V 16:09:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275332 (V, A, ohm, ...), Measured Value = 95.649870 (C, atm, Hz, ...) 16:09:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.088999 V 16:09:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.088999 (V, A, ohm, ...), Measured Value = 6.674925 (C, atm, Hz, ...) 16:09:37 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 16:09:37 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.909666 (C, atm, Hz, ...) 16:09:37 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.36 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.31 P5 = Ambient, Value = 23.73 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 95.65 P9 = Return Pres(psi), Value = 6.67 P10 = Flow Rate(gpm), Value = 0.91 16:09:37 Magnet system MAIN current ramping to 75.0000 A... 16:10:33 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:10:35 Main (V) Voltage Measurement, V = 2.671865 V 16:10:40 Temperature Measurement, Probe Number = 0, T = 26.358000 C 16:10:42 Temperature Measurement, Probe Number = 1, T = 28.207000 C 16:10:45 Temperature Measurement, Probe Number = 2, T = 28.126000 C 16:10:47 Temperature Measurement, Probe Number = 3, T = 23.736000 C 16:10:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342277 V 16:10:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342277 (V, A, ohm, ...), Measured Value = 28.642740 (C, atm, Hz, ...) 16:10:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.373109 V 16:10:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373109 (V, A, ohm, ...), Measured Value = 29.070953 (C, atm, Hz, ...) 16:10:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279214 V 16:10:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279214 (V, A, ohm, ...), Measured Value = 95.941080 (C, atm, Hz, ...) 16:10:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089145 V 16:10:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089145 (V, A, ohm, ...), Measured Value = 6.685875 (C, atm, Hz, ...) 16:11:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 16:11:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900491 (C, atm, Hz, ...) 16:11:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.36 P3 = Right Coil Outgoing Side, Value = 28.21 P4 = Left Coil Middle, Value = 28.13 P5 = Ambient, Value = 23.74 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.07 P8 = Supply Pres(psi), Value = 95.94 P9 = Return Pres(psi), Value = 6.69 P10 = Flow Rate(gpm), Value = 0.90 16:11:03 Magnetic Field Measurement Measuring the magnet strength... 16:11:03 Integrated Voltage Measurement... 16:11:05 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:11:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014395730 Vs 16:11:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014389263 Vs 16:11:27 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:11:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014396470 Vs 16:11:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014389114 Vs 16:11:48 Magnet Current for MAIN, Imag = 75.0217 A Vtrans = 0.750216 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:11:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399670 Vs 16:12:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014388318 Vs 16:12:09 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:12:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014396917 Vs 16:12:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014387714 Vs 16:12:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014392900 +- 0.000000654 Vs 16:12:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014392900 +- 0.000000654 Vs BL = -0.15992111 +- 0.00000727 Tm 16:12:32 Position moved: 0.000000 m 16:12:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15992 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15992 0.00001 -0.15992 0.00000 16:12:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15992 0.00001 SL = -0.1599211 +- 0.0000073 Tm^2/m^n 16:12:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599211 +- 0.0000073 Tm^2/m^n 16:12:34 Position moved: 0.000000 m 16:12:34 Magnet system MAIN current ramping to 125.0000 A... 16:13:14 Magnet system MAIN current ramping to 0.0000 A... 16:14:35 Magnet system MAIN current ramping to 125.0000 A... 16:15:57 Magnet system MAIN current ramping to 0.0000 A... 16:17:19 Magnet system MAIN current ramping to 125.0000 A... 16:18:41 Magnet system MAIN current ramping to 0.0000 A... 16:20:05 Position moved: 0.000000 m 16:20:08 Magnet system MAIN current ramping to 87.5000 A... 16:21:11 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:21:13 Main (V) Voltage Measurement, V = 3.116729 V 16:21:18 Temperature Measurement, Probe Number = 0, T = 26.402000 C 16:21:20 Temperature Measurement, Probe Number = 1, T = 28.217000 C 16:21:22 Temperature Measurement, Probe Number = 2, T = 28.115000 C 16:21:24 Temperature Measurement, Probe Number = 3, T = 23.745000 C 16:21:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342624 V 16:21:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342624 (V, A, ohm, ...), Measured Value = 28.647549 (C, atm, Hz, ...) 16:21:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366223 V 16:21:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366223 (V, A, ohm, ...), Measured Value = 28.975315 (C, atm, Hz, ...) 16:21:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283827 V 16:21:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283827 (V, A, ohm, ...), Measured Value = 96.287032 (C, atm, Hz, ...) 16:21:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089173 V 16:21:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089173 (V, A, ohm, ...), Measured Value = 6.688005 (C, atm, Hz, ...) 16:21:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 16:21:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.886742 (C, atm, Hz, ...) 16:21:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.40 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 28.11 P5 = Ambient, Value = 23.75 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 28.98 P8 = Supply Pres(psi), Value = 96.29 P9 = Return Pres(psi), Value = 6.69 P10 = Flow Rate(gpm), Value = 0.89 16:21:41 Magnetic Field Measurement Measuring the magnet strength... 16:21:41 Integrated Voltage Measurement... 16:21:43 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:21:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016768466 Vs 16:22:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016762457 Vs 16:22:05 Magnet Current for MAIN, Imag = 87.4685 A Vtrans = 0.874684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:22:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016769586 Vs 16:22:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016760959 Vs 16:22:26 Magnet Current for MAIN, Imag = 87.4685 A Vtrans = 0.874684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:22:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016770218 Vs 16:22:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016762281 Vs 16:22:46 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:22:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016770853 Vs 16:23:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016761366 Vs 16:23:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016765773 +- 0.000000415 Vs 16:23:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016765773 +- 0.000000415 Vs BL = -0.18628637 +- 0.00000461 Tm 16:23:09 Position moved: 0.000000 m 16:23:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18629 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18629 0.00000 -0.18629 0.00000 16:23:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18629 0.00000 SL = -0.1862864 +- 0.0000046 Tm^2/m^n 16:23:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1862864 +- 0.0000046 Tm^2/m^n 16:23:12 Position moved: 0.000000 m 16:23:12 Magnet system MAIN current ramping to 75.0000 A... 16:23:32 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:23:34 Main (V) Voltage Measurement, V = 2.675023 V 16:23:39 Temperature Measurement, Probe Number = 0, T = 26.402000 C 16:23:41 Temperature Measurement, Probe Number = 1, T = 28.284000 C 16:23:43 Temperature Measurement, Probe Number = 2, T = 28.230000 C 16:23:45 Temperature Measurement, Probe Number = 3, T = 23.746000 C 16:23:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342625 V 16:23:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342625 (V, A, ohm, ...), Measured Value = 28.647567 (C, atm, Hz, ...) 16:23:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359816 V 16:23:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359816 (V, A, ohm, ...), Measured Value = 28.886332 (C, atm, Hz, ...) 16:23:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284167 V 16:23:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284167 (V, A, ohm, ...), Measured Value = 96.312510 (C, atm, Hz, ...) 16:23:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089077 V 16:23:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089077 (V, A, ohm, ...), Measured Value = 6.680738 (C, atm, Hz, ...) 16:24:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 16:24:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.902936 (C, atm, Hz, ...) 16:24:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.40 P3 = Right Coil Outgoing Side, Value = 28.28 P4 = Left Coil Middle, Value = 28.23 P5 = Ambient, Value = 23.75 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 96.31 P9 = Return Pres(psi), Value = 6.68 P10 = Flow Rate(gpm), Value = 0.90 16:24:02 Magnet system MAIN current ramping to 125.0000 A... 16:24:44 Magnet Current for MAIN, Imag = 124.9928 A Vtrans = 1.249927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:24:46 Main (V) Voltage Measurement, V = 4.461502 V 16:24:51 Temperature Measurement, Probe Number = 0, T = 26.404000 C 16:24:53 Temperature Measurement, Probe Number = 1, T = 28.310000 C 16:24:55 Temperature Measurement, Probe Number = 2, T = 28.297000 C 16:24:57 Temperature Measurement, Probe Number = 3, T = 23.764000 C 16:24:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342419 V 16:24:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342419 (V, A, ohm, ...), Measured Value = 28.644714 (C, atm, Hz, ...) 16:25:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362561 V 16:25:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362561 (V, A, ohm, ...), Measured Value = 28.924454 (C, atm, Hz, ...) 16:25:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270990 V 16:25:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270990 (V, A, ohm, ...), Measured Value = 95.324272 (C, atm, Hz, ...) 16:25:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089230 V 16:25:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089230 (V, A, ohm, ...), Measured Value = 6.692265 (C, atm, Hz, ...) 16:25:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 16:25:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905006 (C, atm, Hz, ...) 16:25:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.40 P3 = Right Coil Outgoing Side, Value = 28.31 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.32 P9 = Return Pres(psi), Value = 6.69 P10 = Flow Rate(gpm), Value = 0.91 16:25:14 Magnet system MAIN current ramping to 0.0000 A... 16:26:38 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:26:40 Main (V) Voltage Measurement, V = 0.000001 V 16:26:45 Temperature Measurement, Probe Number = 0, T = 26.413000 C 16:26:47 Temperature Measurement, Probe Number = 1, T = 28.408000 C 16:26:49 Temperature Measurement, Probe Number = 2, T = 28.298000 C 16:26:51 Temperature Measurement, Probe Number = 3, T = 23.763000 C 16:26:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341737 V 16:26:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341737 (V, A, ohm, ...), Measured Value = 28.635242 (C, atm, Hz, ...) 16:26:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372024 V 16:26:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372024 (V, A, ohm, ...), Measured Value = 29.055883 (C, atm, Hz, ...) 16:26:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281763 V 16:26:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281763 (V, A, ohm, ...), Measured Value = 96.132217 (C, atm, Hz, ...) 16:27:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089323 V 16:27:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089323 (V, A, ohm, ...), Measured Value = 6.699240 (C, atm, Hz, ...) 16:27:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 16:27:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892778 (C, atm, Hz, ...) 16:27:08 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.41 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.06 P8 = Supply Pres(psi), Value = 96.13 P9 = Return Pres(psi), Value = 6.70 P10 = Flow Rate(gpm), Value = 0.89 16:27:08 Magnet system MAIN current ramping to 125.0000 A... 16:28:31 Magnet Current for MAIN, Imag = 124.9924 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:28:33 Main (V) Voltage Measurement, V = 4.461537 V 16:28:38 Temperature Measurement, Probe Number = 0, T = 26.411000 C 16:28:40 Temperature Measurement, Probe Number = 1, T = 28.227000 C 16:28:43 Temperature Measurement, Probe Number = 2, T = 28.230000 C 16:28:45 Temperature Measurement, Probe Number = 3, T = 23.753000 C 16:28:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341632 V 16:28:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341632 (V, A, ohm, ...), Measured Value = 28.633771 (C, atm, Hz, ...) 16:28:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369598 V 16:28:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369598 (V, A, ohm, ...), Measured Value = 29.022192 (C, atm, Hz, ...) 16:28:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276268 V 16:28:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276268 (V, A, ohm, ...), Measured Value = 95.720107 (C, atm, Hz, ...) 16:28:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089345 V 16:28:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089345 (V, A, ohm, ...), Measured Value = 6.700890 (C, atm, Hz, ...) 16:29:01 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 16:29:01 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.898283 (C, atm, Hz, ...) 16:29:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.41 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.23 P5 = Ambient, Value = 23.75 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 95.72 P9 = Return Pres(psi), Value = 6.70 P10 = Flow Rate(gpm), Value = 0.90 16:29:01 Magnet system MAIN current ramping to 0.0000 A... 16:30:24 Magnet Current for MAIN, Imag = -0.0008 A Vtrans = -0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:30:27 Main (V) Voltage Measurement, V = 0.000000 V 16:30:32 Temperature Measurement, Probe Number = 0, T = 26.420000 C 16:30:34 Temperature Measurement, Probe Number = 1, T = 28.416000 C 16:30:36 Temperature Measurement, Probe Number = 2, T = 28.265000 C 16:30:38 Temperature Measurement, Probe Number = 3, T = 23.764000 C 16:30:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342045 V 16:30:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342045 (V, A, ohm, ...), Measured Value = 28.639511 (C, atm, Hz, ...) 16:30:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370550 V 16:30:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370550 (V, A, ohm, ...), Measured Value = 29.035414 (C, atm, Hz, ...) 16:30:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284029 V 16:30:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284029 (V, A, ohm, ...), Measured Value = 96.302145 (C, atm, Hz, ...) 16:30:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089100 V 16:30:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089100 (V, A, ohm, ...), Measured Value = 6.682485 (C, atm, Hz, ...) 16:30:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 16:30:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895500 (C, atm, Hz, ...) 16:30:54 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.42 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.27 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 96.30 P9 = Return Pres(psi), Value = 6.68 P10 = Flow Rate(gpm), Value = 0.90 16:30:54 Magnet system MAIN current ramping to 125.0000 A... 16:32:19 Magnet Current for MAIN, Imag = 124.9924 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:32:21 Main (V) Voltage Measurement, V = 4.461980 V 16:32:26 Temperature Measurement, Probe Number = 0, T = 26.420000 C 16:32:29 Temperature Measurement, Probe Number = 1, T = 28.235000 C 16:32:31 Temperature Measurement, Probe Number = 2, T = 28.192000 C 16:32:33 Temperature Measurement, Probe Number = 3, T = 23.794000 C 16:32:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342463 V 16:32:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342463 (V, A, ohm, ...), Measured Value = 28.645324 (C, atm, Hz, ...) 16:32:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368844 V 16:32:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368844 (V, A, ohm, ...), Measured Value = 29.011715 (C, atm, Hz, ...) 16:32:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275927 V 16:32:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275927 (V, A, ohm, ...), Measured Value = 95.694533 (C, atm, Hz, ...) 16:32:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089260 V 16:32:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089260 (V, A, ohm, ...), Measured Value = 6.694493 (C, atm, Hz, ...) 16:32:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 16:32:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892786 (C, atm, Hz, ...) 16:32:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.42 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.19 P5 = Ambient, Value = 23.79 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 95.69 P9 = Return Pres(psi), Value = 6.69 P10 = Flow Rate(gpm), Value = 0.89 16:32:49 Magnet system MAIN current ramping to 0.0000 A... 16:34:14 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:34:16 Main (V) Voltage Measurement, V = 0.000000 V 16:34:21 Temperature Measurement, Probe Number = 0, T = 26.429000 C 16:34:23 Temperature Measurement, Probe Number = 1, T = 28.435000 C 16:34:26 Temperature Measurement, Probe Number = 2, T = 28.277000 C 16:34:28 Temperature Measurement, Probe Number = 3, T = 23.775000 C 16:34:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342417 V 16:34:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342417 (V, A, ohm, ...), Measured Value = 28.644678 (C, atm, Hz, ...) 16:34:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370268 V 16:34:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370268 (V, A, ohm, ...), Measured Value = 29.031503 (C, atm, Hz, ...) 16:34:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274036 V 16:34:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274036 (V, A, ohm, ...), Measured Value = 95.552707 (C, atm, Hz, ...) 16:34:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089539 V 16:34:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089539 (V, A, ohm, ...), Measured Value = 6.715425 (C, atm, Hz, ...) 16:34:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 16:34:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897782 (C, atm, Hz, ...) 16:34:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.43 P3 = Right Coil Outgoing Side, Value = 28.43 P4 = Left Coil Middle, Value = 28.28 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 95.55 P9 = Return Pres(psi), Value = 6.72 P10 = Flow Rate(gpm), Value = 0.90 16:34:44 Magnet system MAIN current ramping to 125.0000 A... 16:36:08 Magnet Current for MAIN, Imag = 124.9922 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:36:10 Main (V) Voltage Measurement, V = 4.461789 V 16:36:16 Temperature Measurement, Probe Number = 0, T = 26.441000 C 16:36:18 Temperature Measurement, Probe Number = 1, T = 28.240000 C 16:36:20 Temperature Measurement, Probe Number = 2, T = 28.169000 C 16:36:22 Temperature Measurement, Probe Number = 3, T = 23.775000 C 16:36:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342104 V 16:36:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342104 (V, A, ohm, ...), Measured Value = 28.640337 (C, atm, Hz, ...) 16:36:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368668 V 16:36:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368668 (V, A, ohm, ...), Measured Value = 29.009275 (C, atm, Hz, ...) 16:36:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282596 V 16:36:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282596 (V, A, ohm, ...), Measured Value = 96.194708 (C, atm, Hz, ...) 16:36:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089378 V 16:36:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089378 (V, A, ohm, ...), Measured Value = 6.703313 (C, atm, Hz, ...) 16:36:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000892 V 16:36:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000892 (V, A, ohm, ...), Measured Value = 0.891638 (C, atm, Hz, ...) 16:36:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.44 P3 = Right Coil Outgoing Side, Value = 28.24 P4 = Left Coil Middle, Value = 28.17 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 96.19 P9 = Return Pres(psi), Value = 6.70 P10 = Flow Rate(gpm), Value = 0.89 16:36:38 Magnet system MAIN current ramping to 0.0000 A... 16:38:02 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:38:04 Main (V) Voltage Measurement, V = -0.000001 V 16:38:09 Temperature Measurement, Probe Number = 0, T = 26.436000 C 16:38:11 Temperature Measurement, Probe Number = 1, T = 28.452000 C 16:38:13 Temperature Measurement, Probe Number = 2, T = 28.321000 C 16:38:15 Temperature Measurement, Probe Number = 3, T = 23.763000 C 16:38:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342366 V 16:38:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342366 (V, A, ohm, ...), Measured Value = 28.643979 (C, atm, Hz, ...) 16:38:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370107 V 16:38:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370107 (V, A, ohm, ...), Measured Value = 29.029261 (C, atm, Hz, ...) 16:38:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278880 V 16:38:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278880 (V, A, ohm, ...), Measured Value = 95.915993 (C, atm, Hz, ...) 16:38:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089491 V 16:38:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089491 (V, A, ohm, ...), Measured Value = 6.711840 (C, atm, Hz, ...) 16:38:32 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 16:38:32 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892787 (C, atm, Hz, ...) 16:38:32 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.44 P3 = Right Coil Outgoing Side, Value = 28.45 P4 = Left Coil Middle, Value = 28.32 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 95.92 P9 = Return Pres(psi), Value = 6.71 P10 = Flow Rate(gpm), Value = 0.89 16:38:32 Magnet system MAIN current ramping to 75.0000 A... 16:39:27 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:39:29 Main (V) Voltage Measurement, V = 2.671912 V 16:39:34 Temperature Measurement, Probe Number = 0, T = 26.450000 C 16:39:36 Temperature Measurement, Probe Number = 1, T = 28.207000 C 16:39:38 Temperature Measurement, Probe Number = 2, T = 28.116000 C 16:39:41 Temperature Measurement, Probe Number = 3, T = 23.764000 C 16:39:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342435 V 16:39:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342435 (V, A, ohm, ...), Measured Value = 28.644929 (C, atm, Hz, ...) 16:39:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372462 V 16:39:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372462 (V, A, ohm, ...), Measured Value = 29.061965 (C, atm, Hz, ...) 16:39:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278615 V 16:39:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278615 (V, A, ohm, ...), Measured Value = 95.896133 (C, atm, Hz, ...) 16:39:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089703 V 16:39:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089703 (V, A, ohm, ...), Measured Value = 6.727725 (C, atm, Hz, ...) 16:39:57 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 16:39:57 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907941 (C, atm, Hz, ...) 16:39:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.21 P4 = Left Coil Middle, Value = 28.12 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.06 P8 = Supply Pres(psi), Value = 95.90 P9 = Return Pres(psi), Value = 6.73 P10 = Flow Rate(gpm), Value = 0.91 16:39:57 Magnetic Field Measurement Measuring the magnet strength... 16:39:57 Integrated Voltage Measurement... 16:39:59 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397669 Vs 16:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014388365 Vs 16:40:21 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:40:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014395549 Vs 16:40:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014391409 Vs 16:40:42 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:40:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014396584 Vs 16:41:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014391262 Vs 16:41:03 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:41:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014398117 Vs 16:41:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014391689 Vs 16:41:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014393831 +- 0.000000697 Vs 16:41:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014393831 +- 0.000000697 Vs BL = -0.15993145 +- 0.00000775 Tm 16:41:26 Position moved: 0.000000 m 16:41:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15993 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15993 0.00001 -0.15993 0.00000 16:41:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15993 0.00001 SL = -0.1599315 +- 0.0000077 Tm^2/m^n 16:41:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599315 +- 0.0000077 Tm^2/m^n 16:41:29 Position moved: 0.000000 m 16:41:29 Magnet system MAIN current ramping to 125.0000 A... 16:42:08 Magnet system MAIN current ramping to 0.0000 A... 16:43:30 Magnet system MAIN current ramping to 125.0000 A... 16:44:52 Magnet system MAIN current ramping to 0.0000 A... 16:46:13 Magnet system MAIN current ramping to 125.0000 A... 16:47:35 Magnet system MAIN current ramping to 0.0000 A... 16:49:00 Position moved: 0.000000 m 16:49:02 Magnet system MAIN current ramping to 87.5000 A... 16:50:05 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:50:07 Main (V) Voltage Measurement, V = 3.116966 V 16:50:12 Temperature Measurement, Probe Number = 0, T = 26.472000 C 16:50:14 Temperature Measurement, Probe Number = 1, T = 28.180000 C 16:50:16 Temperature Measurement, Probe Number = 2, T = 28.175000 C 16:50:18 Temperature Measurement, Probe Number = 3, T = 23.758000 C 16:50:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343641 V 16:50:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343641 (V, A, ohm, ...), Measured Value = 28.661686 (C, atm, Hz, ...) 16:50:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367393 V 16:50:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367393 (V, A, ohm, ...), Measured Value = 28.991568 (C, atm, Hz, ...) 16:50:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280755 V 16:50:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280755 (V, A, ohm, ...), Measured Value = 96.056655 (C, atm, Hz, ...) 16:50:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089580 V 16:50:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089580 (V, A, ohm, ...), Measured Value = 6.718522 (C, atm, Hz, ...) 16:50:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 16:50:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.897191 (C, atm, Hz, ...) 16:50:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.18 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 28.99 P8 = Supply Pres(psi), Value = 96.06 P9 = Return Pres(psi), Value = 6.72 P10 = Flow Rate(gpm), Value = 0.90 16:50:35 Magnetic Field Measurement Measuring the magnet strength... 16:50:35 Integrated Voltage Measurement... 16:50:37 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772478 Vs 16:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016763347 Vs 16:50:59 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:51:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772126 Vs 16:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766782 Vs 16:51:20 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772546 Vs 16:51:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766947 Vs 16:51:41 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016771429 Vs 16:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016763830 Vs 16:51:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016768686 +- 0.000000926 Vs 16:51:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016768686 +- 0.000000926 Vs BL = -0.18631873 +- 0.00001029 Tm 16:52:03 Position moved: 0.000000 m 16:52:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18632 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18632 0.00001 -0.18632 0.00000 16:52:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18632 0.00001 SL = -0.1863187 +- 0.0000103 Tm^2/m^n 16:52:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863187 +- 0.0000103 Tm^2/m^n 16:52:06 Position moved: 0.000000 m 16:52:06 Magnet system MAIN current ramping to 75.0000 A... 16:52:26 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:52:28 Main (V) Voltage Measurement, V = 2.675143 V 16:52:33 Temperature Measurement, Probe Number = 0, T = 26.470000 C 16:52:36 Temperature Measurement, Probe Number = 1, T = 28.288000 C 16:52:38 Temperature Measurement, Probe Number = 2, T = 28.254000 C 16:52:40 Temperature Measurement, Probe Number = 3, T = 23.767000 C 16:52:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343470 V 16:52:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343470 (V, A, ohm, ...), Measured Value = 28.659300 (C, atm, Hz, ...) 16:52:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361012 V 16:52:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361012 (V, A, ohm, ...), Measured Value = 28.902944 (C, atm, Hz, ...) 16:52:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275315 V 16:52:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275315 (V, A, ohm, ...), Measured Value = 95.648610 (C, atm, Hz, ...) 16:52:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089668 V 16:52:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089668 (V, A, ohm, ...), Measured Value = 6.725107 (C, atm, Hz, ...) 16:52:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 16:52:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.897377 (C, atm, Hz, ...) 16:52:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.29 P4 = Left Coil Middle, Value = 28.25 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 28.90 P8 = Supply Pres(psi), Value = 95.65 P9 = Return Pres(psi), Value = 6.73 P10 = Flow Rate(gpm), Value = 0.90 16:52:56 Magnet system MAIN current ramping to 125.0000 A... 16:53:38 Magnet Current for MAIN, Imag = 124.9921 A Vtrans = 1.249920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:53:40 Main (V) Voltage Measurement, V = 4.461147 V 16:53:45 Temperature Measurement, Probe Number = 0, T = 26.477000 C 16:53:47 Temperature Measurement, Probe Number = 1, T = 28.335000 C 16:53:49 Temperature Measurement, Probe Number = 2, T = 28.293000 C 16:53:51 Temperature Measurement, Probe Number = 3, T = 23.766000 C 16:53:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343578 V 16:53:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343578 (V, A, ohm, ...), Measured Value = 28.660807 (C, atm, Hz, ...) 16:53:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363265 V 16:53:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363265 (V, A, ohm, ...), Measured Value = 28.934232 (C, atm, Hz, ...) 16:53:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279592 V 16:53:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279592 (V, A, ohm, ...), Measured Value = 95.969370 (C, atm, Hz, ...) 16:54:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089702 V 16:54:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089702 (V, A, ohm, ...), Measured Value = 6.727627 (C, atm, Hz, ...) 16:54:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 16:54:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.897295 (C, atm, Hz, ...) 16:54:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.48 P3 = Right Coil Outgoing Side, Value = 28.34 P4 = Left Coil Middle, Value = 28.29 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 28.93 P8 = Supply Pres(psi), Value = 95.97 P9 = Return Pres(psi), Value = 6.73 P10 = Flow Rate(gpm), Value = 0.90 16:54:08 Magnet system MAIN current ramping to 0.0000 A... 16:55:32 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:55:34 Main (V) Voltage Measurement, V = -0.000003 V 16:55:39 Temperature Measurement, Probe Number = 0, T = 26.482000 C 16:55:41 Temperature Measurement, Probe Number = 1, T = 28.474000 C 16:55:43 Temperature Measurement, Probe Number = 2, T = 28.303000 C 16:55:45 Temperature Measurement, Probe Number = 3, T = 23.765000 C 16:55:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342910 V 16:55:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342910 (V, A, ohm, ...), Measured Value = 28.651532 (C, atm, Hz, ...) 16:55:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372867 V 16:55:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372867 (V, A, ohm, ...), Measured Value = 29.067599 (C, atm, Hz, ...) 16:55:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284911 V 16:55:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284911 (V, A, ohm, ...), Measured Value = 96.368310 (C, atm, Hz, ...) 16:55:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089870 V 16:55:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089870 (V, A, ohm, ...), Measured Value = 6.740220 (C, atm, Hz, ...) 16:56:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000901 V 16:56:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000901 (V, A, ohm, ...), Measured Value = 0.900597 (C, atm, Hz, ...) 16:56:02 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.48 P3 = Right Coil Outgoing Side, Value = 28.47 P4 = Left Coil Middle, Value = 28.30 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.07 P8 = Supply Pres(psi), Value = 96.37 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.90 16:56:02 Magnet system MAIN current ramping to 125.0000 A... 16:57:25 Magnet Current for MAIN, Imag = 124.9932 A Vtrans = 1.249931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:57:27 Main (V) Voltage Measurement, V = 4.461850 V 16:57:32 Temperature Measurement, Probe Number = 0, T = 26.496000 C 16:57:34 Temperature Measurement, Probe Number = 1, T = 28.258000 C 16:57:36 Temperature Measurement, Probe Number = 2, T = 28.187000 C 16:57:39 Temperature Measurement, Probe Number = 3, T = 23.769000 C 16:57:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342647 V 16:57:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342647 (V, A, ohm, ...), Measured Value = 28.647872 (C, atm, Hz, ...) 16:57:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370264 V 16:57:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370264 (V, A, ohm, ...), Measured Value = 29.031450 (C, atm, Hz, ...) 16:57:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283344 V 16:57:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283344 (V, A, ohm, ...), Measured Value = 96.250800 (C, atm, Hz, ...) 16:57:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089853 V 16:57:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089853 (V, A, ohm, ...), Measured Value = 6.738960 (C, atm, Hz, ...) 16:57:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 16:57:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897775 (C, atm, Hz, ...) 16:57:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 28.19 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 96.25 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.90 16:57:55 Magnet system MAIN current ramping to 0.0000 A... 16:59:19 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 16:59:21 Main (V) Voltage Measurement, V = -0.000001 V 16:59:26 Temperature Measurement, Probe Number = 0, T = 26.506000 C 16:59:28 Temperature Measurement, Probe Number = 1, T = 28.464000 C 16:59:30 Temperature Measurement, Probe Number = 2, T = 28.243000 C 16:59:32 Temperature Measurement, Probe Number = 3, T = 23.777000 C 16:59:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342798 V 16:59:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342798 (V, A, ohm, ...), Measured Value = 28.649971 (C, atm, Hz, ...) 16:59:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371555 V 16:59:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371555 (V, A, ohm, ...), Measured Value = 29.049371 (C, atm, Hz, ...) 16:59:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282185 V 16:59:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282185 (V, A, ohm, ...), Measured Value = 96.163898 (C, atm, Hz, ...) 16:59:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089945 V 16:59:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089945 (V, A, ohm, ...), Measured Value = 6.745838 (C, atm, Hz, ...) 16:59:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 16:59:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905400 (C, atm, Hz, ...) 16:59:49 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.46 P4 = Left Coil Middle, Value = 28.24 P5 = Ambient, Value = 23.78 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.05 P8 = Supply Pres(psi), Value = 96.16 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.91 16:59:49 Magnet system MAIN current ramping to 125.0000 A... 17:01:13 Magnet Current for MAIN, Imag = 124.9928 A Vtrans = 1.249927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:01:15 Main (V) Voltage Measurement, V = 4.461970 V 17:01:20 Temperature Measurement, Probe Number = 0, T = 26.506000 C 17:01:22 Temperature Measurement, Probe Number = 1, T = 28.175000 C 17:01:24 Temperature Measurement, Probe Number = 2, T = 28.190000 C 17:01:26 Temperature Measurement, Probe Number = 3, T = 23.728000 C 17:01:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342830 V 17:01:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342830 (V, A, ohm, ...), Measured Value = 28.650419 (C, atm, Hz, ...) 17:01:31 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370462 V 17:01:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370462 (V, A, ohm, ...), Measured Value = 29.034194 (C, atm, Hz, ...) 17:01:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272946 V 17:01:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272946 (V, A, ohm, ...), Measured Value = 95.470942 (C, atm, Hz, ...) 17:01:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089925 V 17:01:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089925 (V, A, ohm, ...), Measured Value = 6.744390 (C, atm, Hz, ...) 17:01:43 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 17:01:43 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910384 (C, atm, Hz, ...) 17:01:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.19 P5 = Ambient, Value = 23.73 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 95.47 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.91 17:01:43 Magnet system MAIN current ramping to 0.0000 A... 17:03:06 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:03:09 Main (V) Voltage Measurement, V = 0.000000 V 17:03:14 Temperature Measurement, Probe Number = 0, T = 26.500000 C 17:03:16 Temperature Measurement, Probe Number = 1, T = 28.424000 C 17:03:18 Temperature Measurement, Probe Number = 2, T = 28.234000 C 17:03:20 Temperature Measurement, Probe Number = 3, T = 23.763000 C 17:03:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342693 V 17:03:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342693 (V, A, ohm, ...), Measured Value = 28.648518 (C, atm, Hz, ...) 17:03:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371781 V 17:03:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371781 (V, A, ohm, ...), Measured Value = 29.052511 (C, atm, Hz, ...) 17:03:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281471 V 17:03:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281471 (V, A, ohm, ...), Measured Value = 96.110325 (C, atm, Hz, ...) 17:03:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089751 V 17:03:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089751 (V, A, ohm, ...), Measured Value = 6.731310 (C, atm, Hz, ...) 17:03:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000884 V 17:03:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000884 (V, A, ohm, ...), Measured Value = 0.884239 (C, atm, Hz, ...) 17:03:36 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.23 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.05 P8 = Supply Pres(psi), Value = 96.11 P9 = Return Pres(psi), Value = 6.73 P10 = Flow Rate(gpm), Value = 0.88 17:03:36 Magnet system MAIN current ramping to 125.0000 A... 17:05:00 Magnet Current for MAIN, Imag = 124.9957 A Vtrans = 1.249956 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:05:02 Main (V) Voltage Measurement, V = 4.461752 V 17:05:08 Temperature Measurement, Probe Number = 0, T = 26.510000 C 17:05:10 Temperature Measurement, Probe Number = 1, T = 28.170000 C 17:05:12 Temperature Measurement, Probe Number = 2, T = 28.177000 C 17:05:14 Temperature Measurement, Probe Number = 3, T = 23.777000 C 17:05:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342076 V 17:05:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342076 (V, A, ohm, ...), Measured Value = 28.639942 (C, atm, Hz, ...) 17:05:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370329 V 17:05:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370329 (V, A, ohm, ...), Measured Value = 29.032346 (C, atm, Hz, ...) 17:05:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283707 V 17:05:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283707 (V, A, ohm, ...), Measured Value = 96.278017 (C, atm, Hz, ...) 17:05:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089924 V 17:05:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089924 (V, A, ohm, ...), Measured Value = 6.744293 (C, atm, Hz, ...) 17:05:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 17:05:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.889779 (C, atm, Hz, ...) 17:05:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.17 P4 = Left Coil Middle, Value = 28.18 P5 = Ambient, Value = 23.78 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 96.28 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.89 17:05:30 Magnet system MAIN current ramping to 0.0000 A... 17:06:54 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:06:56 Main (V) Voltage Measurement, V = 0.000000 V 17:07:02 Temperature Measurement, Probe Number = 0, T = 26.504000 C 17:07:04 Temperature Measurement, Probe Number = 1, T = 28.407000 C 17:07:06 Temperature Measurement, Probe Number = 2, T = 28.223000 C 17:07:08 Temperature Measurement, Probe Number = 3, T = 23.756000 C 17:07:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342528 V 17:07:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342528 (V, A, ohm, ...), Measured Value = 28.646221 (C, atm, Hz, ...) 17:07:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371847 V 17:07:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371847 (V, A, ohm, ...), Measured Value = 29.053426 (C, atm, Hz, ...) 17:07:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275621 V 17:07:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275621 (V, A, ohm, ...), Measured Value = 95.671575 (C, atm, Hz, ...) 17:07:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089849 V 17:07:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089849 (V, A, ohm, ...), Measured Value = 6.738675 (C, atm, Hz, ...) 17:07:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 17:07:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.913004 (C, atm, Hz, ...) 17:07:24 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.22 P5 = Ambient, Value = 23.76 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.05 P8 = Supply Pres(psi), Value = 95.67 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.91 17:07:24 Magnet system MAIN current ramping to 75.0000 A... 17:08:20 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:08:23 Main (V) Voltage Measurement, V = 2.671846 V 17:08:28 Temperature Measurement, Probe Number = 0, T = 26.506000 C 17:08:30 Temperature Measurement, Probe Number = 1, T = 28.175000 C 17:08:32 Temperature Measurement, Probe Number = 2, T = 28.035000 C 17:08:34 Temperature Measurement, Probe Number = 3, T = 23.770000 C 17:08:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.342028 V 17:08:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342028 (V, A, ohm, ...), Measured Value = 28.639278 (C, atm, Hz, ...) 17:08:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.373393 V 17:08:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373393 (V, A, ohm, ...), Measured Value = 29.074900 (C, atm, Hz, ...) 17:08:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281719 V 17:08:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281719 (V, A, ohm, ...), Measured Value = 96.128925 (C, atm, Hz, ...) 17:08:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089913 V 17:08:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089913 (V, A, ohm, ...), Measured Value = 6.743512 (C, atm, Hz, ...) 17:08:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 17:08:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897968 (C, atm, Hz, ...) 17:08:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.04 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 29.07 P8 = Supply Pres(psi), Value = 96.13 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.90 17:08:50 Magnetic Field Measurement Measuring the magnet strength... 17:08:50 Integrated Voltage Measurement... 17:08:53 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:09:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014398780 Vs 17:09:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014391480 Vs 17:09:14 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:09:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401222 Vs 17:09:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014392412 Vs 17:09:35 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:09:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400086 Vs 17:09:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014393496 Vs 17:09:56 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:10:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399823 Vs 17:10:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014392241 Vs 17:10:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014396193 +- 0.000000690 Vs 17:10:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014396193 +- 0.000000690 Vs BL = -0.15995770 +- 0.00000766 Tm 17:10:18 Position moved: 0.000000 m 17:10:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15996 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15996 0.00001 -0.15996 0.00000 17:10:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15996 0.00001 SL = -0.1599577 +- 0.0000077 Tm^2/m^n 17:10:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599577 +- 0.0000077 Tm^2/m^n 17:10:21 Position moved: 0.000000 m 17:10:21 Magnet system MAIN current ramping to 125.0000 A... 17:11:00 Magnet system MAIN current ramping to 0.0000 A... 17:12:21 Magnet system MAIN current ramping to 125.0000 A... 17:13:43 Magnet system MAIN current ramping to 0.0000 A... 17:15:05 Magnet system MAIN current ramping to 125.0000 A... 17:16:27 Magnet system MAIN current ramping to 0.0000 A... 17:17:51 Position moved: 0.000000 m 17:17:54 Magnet system MAIN current ramping to 87.5000 A... 17:18:57 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:18:59 Main (V) Voltage Measurement, V = 3.116588 V 17:19:04 Temperature Measurement, Probe Number = 0, T = 26.525000 C 17:19:06 Temperature Measurement, Probe Number = 1, T = 28.182000 C 17:19:08 Temperature Measurement, Probe Number = 2, T = 28.020000 C 17:19:10 Temperature Measurement, Probe Number = 3, T = 23.773000 C 17:19:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341577 V 17:19:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341577 (V, A, ohm, ...), Measured Value = 28.633018 (C, atm, Hz, ...) 17:19:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365471 V 17:19:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365471 (V, A, ohm, ...), Measured Value = 28.964874 (C, atm, Hz, ...) 17:19:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279137 V 17:19:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279137 (V, A, ohm, ...), Measured Value = 95.935268 (C, atm, Hz, ...) 17:19:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089934 V 17:19:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089934 (V, A, ohm, ...), Measured Value = 6.745065 (C, atm, Hz, ...) 17:19:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 17:19:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890502 (C, atm, Hz, ...) 17:19:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.02 P5 = Ambient, Value = 23.77 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 28.96 P8 = Supply Pres(psi), Value = 95.94 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.89 17:19:27 Magnetic Field Measurement Measuring the magnet strength... 17:19:27 Integrated Voltage Measurement... 17:19:29 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:19:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774051 Vs 17:19:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016764685 Vs 17:19:51 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:20:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773693 Vs 17:20:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016764251 Vs 17:20:11 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:20:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773333 Vs 17:20:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768954 Vs 17:20:32 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:20:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774189 Vs 17:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766132 Vs 17:20:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016769911 +- 0.000000830 Vs 17:20:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016769911 +- 0.000000830 Vs BL = -0.18633234 +- 0.00000923 Tm 17:20:55 Position moved: 0.000000 m 17:20:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18633 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18633 0.00001 -0.18633 0.00000 17:20:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18633 0.00001 SL = -0.1863323 +- 0.0000092 Tm^2/m^n 17:20:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863323 +- 0.0000092 Tm^2/m^n 17:20:58 Position moved: 0.000000 m 17:20:58 Magnet system MAIN current ramping to 75.0000 A... 17:21:18 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:21:20 Main (V) Voltage Measurement, V = 2.674800 V 17:21:25 Temperature Measurement, Probe Number = 0, T = 26.518000 C 17:21:27 Temperature Measurement, Probe Number = 1, T = 28.230000 C 17:21:29 Temperature Measurement, Probe Number = 2, T = 28.132000 C 17:21:31 Temperature Measurement, Probe Number = 3, T = 23.784000 C 17:21:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340559 V 17:21:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340559 (V, A, ohm, ...), Measured Value = 28.618881 (C, atm, Hz, ...) 17:21:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358416 V 17:21:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358416 (V, A, ohm, ...), Measured Value = 28.866885 (C, atm, Hz, ...) 17:21:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281510 V 17:21:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281510 (V, A, ohm, ...), Measured Value = 96.113235 (C, atm, Hz, ...) 17:21:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089893 V 17:21:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089893 (V, A, ohm, ...), Measured Value = 6.741967 (C, atm, Hz, ...) 17:21:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 17:21:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900474 (C, atm, Hz, ...) 17:21:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.13 P5 = Ambient, Value = 23.78 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 28.87 P8 = Supply Pres(psi), Value = 96.11 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.90 17:21:48 Magnet system MAIN current ramping to 125.0000 A... 17:22:29 Magnet Current for MAIN, Imag = 124.9912 A Vtrans = 1.249911 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:22:31 Main (V) Voltage Measurement, V = 4.460739 V 17:22:36 Temperature Measurement, Probe Number = 0, T = 26.528000 C 17:22:39 Temperature Measurement, Probe Number = 1, T = 28.267000 C 17:22:41 Temperature Measurement, Probe Number = 2, T = 28.156000 C 17:22:43 Temperature Measurement, Probe Number = 3, T = 23.778000 C 17:22:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340326 V 17:22:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340326 (V, A, ohm, ...), Measured Value = 28.615633 (C, atm, Hz, ...) 17:22:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361026 V 17:22:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361026 (V, A, ohm, ...), Measured Value = 28.903142 (C, atm, Hz, ...) 17:22:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271203 V 17:22:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271203 (V, A, ohm, ...), Measured Value = 95.340255 (C, atm, Hz, ...) 17:22:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089952 V 17:22:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089952 (V, A, ohm, ...), Measured Value = 6.746422 (C, atm, Hz, ...) 17:22:59 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 17:22:59 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900204 (C, atm, Hz, ...) 17:22:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.27 P4 = Left Coil Middle, Value = 28.16 P5 = Ambient, Value = 23.78 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 28.90 P8 = Supply Pres(psi), Value = 95.34 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.90 17:22:59 Magnet system MAIN current ramping to 0.0000 A... 17:24:24 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:24:26 Main (V) Voltage Measurement, V = -0.000005 V 17:24:31 Temperature Measurement, Probe Number = 0, T = 26.529000 C 17:24:33 Temperature Measurement, Probe Number = 1, T = 28.421000 C 17:24:35 Temperature Measurement, Probe Number = 2, T = 28.146000 C 17:24:37 Temperature Measurement, Probe Number = 3, T = 23.715000 C 17:24:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340367 V 17:24:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340367 (V, A, ohm, ...), Measured Value = 28.616207 (C, atm, Hz, ...) 17:24:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370435 V 17:24:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370435 (V, A, ohm, ...), Measured Value = 29.033818 (C, atm, Hz, ...) 17:24:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271785 V 17:24:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271785 (V, A, ohm, ...), Measured Value = 95.383853 (C, atm, Hz, ...) 17:24:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089912 V 17:24:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089912 (V, A, ohm, ...), Measured Value = 6.743422 (C, atm, Hz, ...) 17:24:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 17:24:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888292 (C, atm, Hz, ...) 17:24:54 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.15 P5 = Ambient, Value = 23.71 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 95.38 P9 = Return Pres(psi), Value = 6.74 P10 = Flow Rate(gpm), Value = 0.89 17:24:54 Magnet system MAIN current ramping to 125.0000 A... 17:26:17 Magnet Current for MAIN, Imag = 124.9932 A Vtrans = 1.249931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:26:20 Main (V) Voltage Measurement, V = 4.461487 V 17:26:25 Temperature Measurement, Probe Number = 0, T = 26.524000 C 17:26:27 Temperature Measurement, Probe Number = 1, T = 28.232000 C 17:26:29 Temperature Measurement, Probe Number = 2, T = 28.088000 C 17:26:31 Temperature Measurement, Probe Number = 3, T = 23.744000 C 17:26:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340584 V 17:26:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340584 (V, A, ohm, ...), Measured Value = 28.619221 (C, atm, Hz, ...) 17:26:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367917 V 17:26:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367917 (V, A, ohm, ...), Measured Value = 28.998853 (C, atm, Hz, ...) 17:26:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275997 V 17:26:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275997 (V, A, ohm, ...), Measured Value = 95.699767 (C, atm, Hz, ...) 17:26:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090063 V 17:26:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090063 (V, A, ohm, ...), Measured Value = 6.754755 (C, atm, Hz, ...) 17:26:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 17:26:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.894828 (C, atm, Hz, ...) 17:26:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.09 P5 = Ambient, Value = 23.74 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 29.00 P8 = Supply Pres(psi), Value = 95.70 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.89 17:26:47 Magnet system MAIN current ramping to 0.0000 A... 17:28:11 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:28:13 Main (V) Voltage Measurement, V = -0.000001 V 17:28:18 Temperature Measurement, Probe Number = 0, T = 26.525000 C 17:28:20 Temperature Measurement, Probe Number = 1, T = 28.446000 C 17:28:23 Temperature Measurement, Probe Number = 2, T = 28.193000 C 17:28:25 Temperature Measurement, Probe Number = 3, T = 23.743000 C 17:28:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340548 V 17:28:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340548 (V, A, ohm, ...), Measured Value = 28.618719 (C, atm, Hz, ...) 17:28:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369391 V 17:28:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369391 (V, A, ohm, ...), Measured Value = 29.019322 (C, atm, Hz, ...) 17:28:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275892 V 17:28:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275892 (V, A, ohm, ...), Measured Value = 95.691915 (C, atm, Hz, ...) 17:28:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090005 V 17:28:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090005 (V, A, ohm, ...), Measured Value = 6.750398 (C, atm, Hz, ...) 17:28:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 17:28:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897865 (C, atm, Hz, ...) 17:28:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.45 P4 = Left Coil Middle, Value = 28.19 P5 = Ambient, Value = 23.74 P6 = Supply Temp(C), Value = 28.62 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 95.69 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.90 17:28:41 Magnet system MAIN current ramping to 125.0000 A... 17:30:05 Magnet Current for MAIN, Imag = 124.9937 A Vtrans = 1.249936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:30:07 Main (V) Voltage Measurement, V = 4.461499 V 17:30:12 Temperature Measurement, Probe Number = 0, T = 26.526000 C 17:30:14 Temperature Measurement, Probe Number = 1, T = 28.226000 C 17:30:16 Temperature Measurement, Probe Number = 2, T = 28.074000 C 17:30:18 Temperature Measurement, Probe Number = 3, T = 23.720000 C 17:30:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.340199 V 17:30:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340199 (V, A, ohm, ...), Measured Value = 28.613875 (C, atm, Hz, ...) 17:30:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367854 V 17:30:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367854 (V, A, ohm, ...), Measured Value = 28.997974 (C, atm, Hz, ...) 17:30:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273389 V 17:30:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273389 (V, A, ohm, ...), Measured Value = 95.504168 (C, atm, Hz, ...) 17:30:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090072 V 17:30:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090072 (V, A, ohm, ...), Measured Value = 6.755430 (C, atm, Hz, ...) 17:30:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 17:30:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.902745 (C, atm, Hz, ...) 17:30:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 28.07 P5 = Ambient, Value = 23.72 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.00 P8 = Supply Pres(psi), Value = 95.50 P9 = Return Pres(psi), Value = 6.76 P10 = Flow Rate(gpm), Value = 0.90 17:30:35 Magnet system MAIN current ramping to 0.0000 A... 17:31:58 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:32:01 Main (V) Voltage Measurement, V = -0.000001 V 17:32:06 Temperature Measurement, Probe Number = 0, T = 26.535000 C 17:32:08 Temperature Measurement, Probe Number = 1, T = 28.422000 C 17:32:10 Temperature Measurement, Probe Number = 2, T = 28.181000 C 17:32:12 Temperature Measurement, Probe Number = 3, T = 23.648000 C 17:32:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339923 V 17:32:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339923 (V, A, ohm, ...), Measured Value = 28.610036 (C, atm, Hz, ...) 17:32:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368877 V 17:32:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368877 (V, A, ohm, ...), Measured Value = 29.012182 (C, atm, Hz, ...) 17:32:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273886 V 17:32:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273886 (V, A, ohm, ...), Measured Value = 95.541465 (C, atm, Hz, ...) 17:32:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090065 V 17:32:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090065 (V, A, ohm, ...), Measured Value = 6.754853 (C, atm, Hz, ...) 17:32:28 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 17:32:28 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.903080 (C, atm, Hz, ...) 17:32:28 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.18 P5 = Ambient, Value = 23.65 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 95.54 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.90 17:32:28 Magnet system MAIN current ramping to 125.0000 A... 17:33:52 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:33:55 Main (V) Voltage Measurement, V = 4.460566 V 17:34:00 Temperature Measurement, Probe Number = 0, T = 26.537000 C 17:34:02 Temperature Measurement, Probe Number = 1, T = 28.217000 C 17:34:04 Temperature Measurement, Probe Number = 2, T = 28.079000 C 17:34:06 Temperature Measurement, Probe Number = 3, T = 23.643000 C 17:34:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339561 V 17:34:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339561 (V, A, ohm, ...), Measured Value = 28.605013 (C, atm, Hz, ...) 17:34:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367638 V 17:34:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367638 (V, A, ohm, ...), Measured Value = 28.994978 (C, atm, Hz, ...) 17:34:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277295 V 17:34:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277295 (V, A, ohm, ...), Measured Value = 95.797125 (C, atm, Hz, ...) 17:34:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090065 V 17:34:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090065 (V, A, ohm, ...), Measured Value = 6.754853 (C, atm, Hz, ...) 17:34:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 17:34:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897793 (C, atm, Hz, ...) 17:34:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 28.08 P5 = Ambient, Value = 23.64 P6 = Supply Temp(C), Value = 28.61 P7 = Return Temp(C), Value = 28.99 P8 = Supply Pres(psi), Value = 95.80 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.90 17:34:22 Magnet system MAIN current ramping to 0.0000 A... 17:35:46 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:35:48 Main (V) Voltage Measurement, V = 0.000000 V 17:35:53 Temperature Measurement, Probe Number = 0, T = 26.540000 C 17:35:55 Temperature Measurement, Probe Number = 1, T = 28.420000 C 17:35:58 Temperature Measurement, Probe Number = 2, T = 28.156000 C 17:36:00 Temperature Measurement, Probe Number = 3, T = 23.699000 C 17:36:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339326 V 17:36:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339326 (V, A, ohm, ...), Measured Value = 28.601747 (C, atm, Hz, ...) 17:36:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368978 V 17:36:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368978 (V, A, ohm, ...), Measured Value = 29.013581 (C, atm, Hz, ...) 17:36:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278709 V 17:36:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278709 (V, A, ohm, ...), Measured Value = 95.903205 (C, atm, Hz, ...) 17:36:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089954 V 17:36:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089954 (V, A, ohm, ...), Measured Value = 6.746520 (C, atm, Hz, ...) 17:36:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 17:36:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880620 (C, atm, Hz, ...) 17:36:16 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.16 P5 = Ambient, Value = 23.70 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 29.01 P8 = Supply Pres(psi), Value = 95.90 P9 = Return Pres(psi), Value = 6.75 P10 = Flow Rate(gpm), Value = 0.88 17:36:16 Magnet system MAIN current ramping to 75.0000 A... 17:37:11 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:37:13 Main (V) Voltage Measurement, V = 2.671545 V 17:37:19 Temperature Measurement, Probe Number = 0, T = 26.537000 C 17:37:21 Temperature Measurement, Probe Number = 1, T = 28.178000 C 17:37:23 Temperature Measurement, Probe Number = 2, T = 27.959000 C 17:37:25 Temperature Measurement, Probe Number = 3, T = 23.684000 C 17:37:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.339080 V 17:37:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339080 (V, A, ohm, ...), Measured Value = 28.598339 (C, atm, Hz, ...) 17:37:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370891 V 17:37:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370891 (V, A, ohm, ...), Measured Value = 29.040150 (C, atm, Hz, ...) 17:37:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278468 V 17:37:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278468 (V, A, ohm, ...), Measured Value = 95.885092 (C, atm, Hz, ...) 17:37:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090092 V 17:37:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090092 (V, A, ohm, ...), Measured Value = 6.756885 (C, atm, Hz, ...) 17:37:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 17:37:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885591 (C, atm, Hz, ...) 17:37:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 27.96 P5 = Ambient, Value = 23.68 P6 = Supply Temp(C), Value = 28.60 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 95.89 P9 = Return Pres(psi), Value = 6.76 P10 = Flow Rate(gpm), Value = 0.89 17:37:41 Magnetic Field Measurement Measuring the magnet strength... 17:37:41 Integrated Voltage Measurement... 17:37:43 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:37:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400828 Vs 17:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395953 Vs 17:38:05 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:38:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400209 Vs 17:38:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395967 Vs 17:38:26 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399746 Vs 17:38:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014394580 Vs 17:38:47 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401898 Vs 17:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014391590 Vs 17:39:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397596 +- 0.000000668 Vs 17:39:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014397596 +- 0.000000668 Vs BL = -0.15997329 +- 0.00000742 Tm 17:39:09 Position moved: 0.000000 m 17:39:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15997 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15997 0.00001 -0.15997 0.00000 17:39:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15997 0.00001 SL = -0.1599733 +- 0.0000074 Tm^2/m^n 17:39:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599733 +- 0.0000074 Tm^2/m^n 17:39:12 Position moved: 0.000000 m 17:39:12 Magnet system MAIN current ramping to 125.0000 A... 17:39:52 Magnet system MAIN current ramping to 0.0000 A... 17:41:13 Magnet system MAIN current ramping to 125.0000 A... 17:42:34 Magnet system MAIN current ramping to 0.0000 A... 17:43:56 Magnet system MAIN current ramping to 125.0000 A... 17:45:17 Magnet system MAIN current ramping to 0.0000 A... 17:46:41 Position moved: 0.000000 m 17:46:44 Magnet system MAIN current ramping to 87.5000 A... 17:47:46 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:47:49 Main (V) Voltage Measurement, V = 3.116067 V 17:47:54 Temperature Measurement, Probe Number = 0, T = 26.555000 C 17:47:56 Temperature Measurement, Probe Number = 1, T = 28.154000 C 17:47:58 Temperature Measurement, Probe Number = 2, T = 27.973000 C 17:48:00 Temperature Measurement, Probe Number = 3, T = 23.671000 C 17:48:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337130 V 17:48:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337130 (V, A, ohm, ...), Measured Value = 28.571250 (C, atm, Hz, ...) 17:48:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362612 V 17:48:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362612 (V, A, ohm, ...), Measured Value = 28.925172 (C, atm, Hz, ...) 17:48:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273689 V 17:48:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273689 (V, A, ohm, ...), Measured Value = 95.526645 (C, atm, Hz, ...) 17:48:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090499 V 17:48:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090499 (V, A, ohm, ...), Measured Value = 6.787402 (C, atm, Hz, ...) 17:48:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 17:48:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896416 (C, atm, Hz, ...) 17:48:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.15 P4 = Left Coil Middle, Value = 27.97 P5 = Ambient, Value = 23.67 P6 = Supply Temp(C), Value = 28.57 P7 = Return Temp(C), Value = 28.93 P8 = Supply Pres(psi), Value = 95.53 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.90 17:48:16 Magnetic Field Measurement Measuring the magnet strength... 17:48:16 Integrated Voltage Measurement... 17:48:19 Magnet Current for MAIN, Imag = 87.4694 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775503 Vs 17:48:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768727 Vs 17:48:40 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:48:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775057 Vs 17:48:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766561 Vs 17:49:01 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:49:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772782 Vs 17:49:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016767576 Vs 17:49:22 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:49:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775836 Vs 17:49:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768626 Vs 17:49:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016771334 +- 0.000000870 Vs 17:49:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016771334 +- 0.000000870 Vs BL = -0.18634815 +- 0.00000966 Tm 17:49:45 Position moved: 0.000000 m 17:49:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18635 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18635 0.00001 -0.18635 0.00000 17:49:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18635 0.00001 SL = -0.1863482 +- 0.0000097 Tm^2/m^n 17:49:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863482 +- 0.0000097 Tm^2/m^n 17:49:48 Position moved: 0.000000 m 17:49:48 Magnet system MAIN current ramping to 75.0000 A... 17:50:08 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:50:10 Main (V) Voltage Measurement, V = 2.674348 V 17:50:15 Temperature Measurement, Probe Number = 0, T = 26.556000 C 17:50:17 Temperature Measurement, Probe Number = 1, T = 28.194000 C 17:50:20 Temperature Measurement, Probe Number = 2, T = 28.099000 C 17:50:22 Temperature Measurement, Probe Number = 3, T = 23.679000 C 17:50:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336537 V 17:50:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336537 (V, A, ohm, ...), Measured Value = 28.563015 (C, atm, Hz, ...) 17:50:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355867 V 17:50:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355867 (V, A, ohm, ...), Measured Value = 28.831489 (C, atm, Hz, ...) 17:50:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272778 V 17:50:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272778 (V, A, ohm, ...), Measured Value = 95.458350 (C, atm, Hz, ...) 17:50:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090348 V 17:50:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090348 (V, A, ohm, ...), Measured Value = 6.776070 (C, atm, Hz, ...) 17:50:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000906 V 17:50:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000906 (V, A, ohm, ...), Measured Value = 0.905820 (C, atm, Hz, ...) 17:50:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.19 P4 = Left Coil Middle, Value = 28.10 P5 = Ambient, Value = 23.68 P6 = Supply Temp(C), Value = 28.56 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 95.46 P9 = Return Pres(psi), Value = 6.78 P10 = Flow Rate(gpm), Value = 0.91 17:50:38 Magnet system MAIN current ramping to 125.0000 A... 17:51:19 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:51:22 Main (V) Voltage Measurement, V = 4.459945 V 17:51:27 Temperature Measurement, Probe Number = 0, T = 26.549000 C 17:51:29 Temperature Measurement, Probe Number = 1, T = 28.263000 C 17:51:31 Temperature Measurement, Probe Number = 2, T = 28.113000 C 17:51:33 Temperature Measurement, Probe Number = 3, T = 23.684000 C 17:51:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336223 V 17:51:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336223 (V, A, ohm, ...), Measured Value = 28.558656 (C, atm, Hz, ...) 17:51:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358147 V 17:51:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358147 (V, A, ohm, ...), Measured Value = 28.863153 (C, atm, Hz, ...) 17:51:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.269112 V 17:51:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.269112 (V, A, ohm, ...), Measured Value = 95.183415 (C, atm, Hz, ...) 17:51:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090239 V 17:51:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090239 (V, A, ohm, ...), Measured Value = 6.767925 (C, atm, Hz, ...) 17:51:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 17:51:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896384 (C, atm, Hz, ...) 17:51:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 28.11 P5 = Ambient, Value = 23.68 P6 = Supply Temp(C), Value = 28.56 P7 = Return Temp(C), Value = 28.86 P8 = Supply Pres(psi), Value = 95.18 P9 = Return Pres(psi), Value = 6.77 P10 = Flow Rate(gpm), Value = 0.90 17:51:49 Magnet system MAIN current ramping to 0.0000 A... 17:53:14 Magnet Current for MAIN, Imag = -0.0007 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:53:16 Main (V) Voltage Measurement, V = -0.000004 V 17:53:21 Temperature Measurement, Probe Number = 0, T = 26.552000 C 17:53:23 Temperature Measurement, Probe Number = 1, T = 28.392000 C 17:53:25 Temperature Measurement, Probe Number = 2, T = 28.119000 C 17:53:27 Temperature Measurement, Probe Number = 3, T = 23.710000 C 17:53:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336040 V 17:53:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336040 (V, A, ohm, ...), Measured Value = 28.556108 (C, atm, Hz, ...) 17:53:31 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367180 V 17:53:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367180 (V, A, ohm, ...), Measured Value = 28.988608 (C, atm, Hz, ...) 17:53:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280235 V 17:53:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280235 (V, A, ohm, ...), Measured Value = 96.017618 (C, atm, Hz, ...) 17:53:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090523 V 17:53:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090523 (V, A, ohm, ...), Measured Value = 6.789240 (C, atm, Hz, ...) 17:53:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000899 V 17:53:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000899 (V, A, ohm, ...), Measured Value = 0.898966 (C, atm, Hz, ...) 17:53:44 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.39 P4 = Left Coil Middle, Value = 28.12 P5 = Ambient, Value = 23.71 P6 = Supply Temp(C), Value = 28.56 P7 = Return Temp(C), Value = 28.99 P8 = Supply Pres(psi), Value = 96.02 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.90 17:53:44 Magnet system MAIN current ramping to 125.0000 A... 17:55:08 Magnet Current for MAIN, Imag = 124.9935 A Vtrans = 1.249934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:55:10 Main (V) Voltage Measurement, V = 4.460362 V 17:55:15 Temperature Measurement, Probe Number = 0, T = 26.543000 C 17:55:17 Temperature Measurement, Probe Number = 1, T = 28.172000 C 17:55:19 Temperature Measurement, Probe Number = 2, T = 28.008000 C 17:55:21 Temperature Measurement, Probe Number = 3, T = 23.623000 C 17:55:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335700 V 17:55:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335700 (V, A, ohm, ...), Measured Value = 28.551390 (C, atm, Hz, ...) 17:55:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.364379 V 17:55:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.364379 (V, A, ohm, ...), Measured Value = 28.949714 (C, atm, Hz, ...) 17:55:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277721 V 17:55:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277721 (V, A, ohm, ...), Measured Value = 95.829098 (C, atm, Hz, ...) 17:55:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090443 V 17:55:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090443 (V, A, ohm, ...), Measured Value = 6.783233 (C, atm, Hz, ...) 17:55:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 17:55:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905373 (C, atm, Hz, ...) 17:55:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.17 P4 = Left Coil Middle, Value = 28.01 P5 = Ambient, Value = 23.62 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.95 P8 = Supply Pres(psi), Value = 95.83 P9 = Return Pres(psi), Value = 6.78 P10 = Flow Rate(gpm), Value = 0.91 17:55:38 Magnet system MAIN current ramping to 0.0000 A... 17:57:01 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:57:04 Main (V) Voltage Measurement, V = -0.000001 V 17:57:09 Temperature Measurement, Probe Number = 0, T = 26.553000 C 17:57:11 Temperature Measurement, Probe Number = 1, T = 28.325000 C 17:57:13 Temperature Measurement, Probe Number = 2, T = 28.097000 C 17:57:15 Temperature Measurement, Probe Number = 3, T = 23.610000 C 17:57:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335517 V 17:57:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335517 (V, A, ohm, ...), Measured Value = 28.548842 (C, atm, Hz, ...) 17:57:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365551 V 17:57:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365551 (V, A, ohm, ...), Measured Value = 28.965986 (C, atm, Hz, ...) 17:57:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.288631 V 17:57:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.288631 (V, A, ohm, ...), Measured Value = 96.647317 (C, atm, Hz, ...) 17:57:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090481 V 17:57:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090481 (V, A, ohm, ...), Measured Value = 6.786045 (C, atm, Hz, ...) 17:57:31 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000901 V 17:57:31 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000901 (V, A, ohm, ...), Measured Value = 0.900937 (C, atm, Hz, ...) 17:57:31 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.32 P4 = Left Coil Middle, Value = 28.10 P5 = Ambient, Value = 23.61 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.97 P8 = Supply Pres(psi), Value = 96.65 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.90 17:57:31 Magnet system MAIN current ramping to 125.0000 A... 17:58:55 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 17:58:57 Main (V) Voltage Measurement, V = 4.460270 V 17:59:02 Temperature Measurement, Probe Number = 0, T = 26.561000 C 17:59:05 Temperature Measurement, Probe Number = 1, T = 28.118000 C 17:59:07 Temperature Measurement, Probe Number = 2, T = 28.029000 C 17:59:09 Temperature Measurement, Probe Number = 3, T = 23.636000 C 17:59:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335444 V 17:59:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335444 (V, A, ohm, ...), Measured Value = 28.547837 (C, atm, Hz, ...) 17:59:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.364140 V 17:59:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.364140 (V, A, ohm, ...), Measured Value = 28.946396 (C, atm, Hz, ...) 17:59:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277729 V 17:59:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277729 (V, A, ohm, ...), Measured Value = 95.829675 (C, atm, Hz, ...) 17:59:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090545 V 17:59:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090545 (V, A, ohm, ...), Measured Value = 6.790890 (C, atm, Hz, ...) 17:59:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 17:59:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895079 (C, atm, Hz, ...) 17:59:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.12 P4 = Left Coil Middle, Value = 28.03 P5 = Ambient, Value = 23.64 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.95 P8 = Supply Pres(psi), Value = 95.83 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.90 17:59:25 Magnet system MAIN current ramping to 0.0000 A... 18:00:49 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:00:51 Main (V) Voltage Measurement, V = 0.000004 V 18:00:56 Temperature Measurement, Probe Number = 0, T = 26.558000 C 18:00:58 Temperature Measurement, Probe Number = 1, T = 28.290000 C 18:01:00 Temperature Measurement, Probe Number = 2, T = 28.098000 C 18:01:03 Temperature Measurement, Probe Number = 3, T = 23.653000 C 18:01:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335841 V 18:01:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335841 (V, A, ohm, ...), Measured Value = 28.553346 (C, atm, Hz, ...) 18:01:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365339 V 18:01:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365339 (V, A, ohm, ...), Measured Value = 28.963043 (C, atm, Hz, ...) 18:01:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274269 V 18:01:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274269 (V, A, ohm, ...), Measured Value = 95.570145 (C, atm, Hz, ...) 18:01:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090459 V 18:01:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090459 (V, A, ohm, ...), Measured Value = 6.784395 (C, atm, Hz, ...) 18:01:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 18:01:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900469 (C, atm, Hz, ...) 18:01:19 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.29 P4 = Left Coil Middle, Value = 28.10 P5 = Ambient, Value = 23.65 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.96 P8 = Supply Pres(psi), Value = 95.57 P9 = Return Pres(psi), Value = 6.78 P10 = Flow Rate(gpm), Value = 0.90 18:01:19 Magnet system MAIN current ramping to 125.0000 A... 18:02:42 Magnet Current for MAIN, Imag = 124.9946 A Vtrans = 1.249945 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:02:45 Main (V) Voltage Measurement, V = 4.460299 V 18:02:50 Temperature Measurement, Probe Number = 0, T = 26.555000 C 18:02:52 Temperature Measurement, Probe Number = 1, T = 28.060000 C 18:02:54 Temperature Measurement, Probe Number = 2, T = 27.996000 C 18:02:56 Temperature Measurement, Probe Number = 3, T = 23.670000 C 18:02:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335395 V 18:02:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335395 (V, A, ohm, ...), Measured Value = 28.547156 (C, atm, Hz, ...) 18:03:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363777 V 18:03:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363777 (V, A, ohm, ...), Measured Value = 28.941354 (C, atm, Hz, ...) 18:03:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274023 V 18:03:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274023 (V, A, ohm, ...), Measured Value = 95.551740 (C, atm, Hz, ...) 18:03:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090570 V 18:03:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090570 (V, A, ohm, ...), Measured Value = 6.792728 (C, atm, Hz, ...) 18:03:12 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 18:03:12 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897523 (C, atm, Hz, ...) 18:03:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 28.00 P5 = Ambient, Value = 23.67 P6 = Supply Temp(C), Value = 28.55 P7 = Return Temp(C), Value = 28.94 P8 = Supply Pres(psi), Value = 95.55 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.90 18:03:12 Magnet system MAIN current ramping to 0.0000 A... 18:04:36 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:04:38 Main (V) Voltage Measurement, V = -0.000001 V 18:04:43 Temperature Measurement, Probe Number = 0, T = 26.550000 C 18:04:46 Temperature Measurement, Probe Number = 1, T = 28.277000 C 18:04:48 Temperature Measurement, Probe Number = 2, T = 28.072000 C 18:04:50 Temperature Measurement, Probe Number = 3, T = 23.634000 C 18:04:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334987 V 18:04:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334987 (V, A, ohm, ...), Measured Value = 28.541488 (C, atm, Hz, ...) 18:04:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365050 V 18:04:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365050 (V, A, ohm, ...), Measured Value = 28.959025 (C, atm, Hz, ...) 18:04:56 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279816 V 18:04:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279816 (V, A, ohm, ...), Measured Value = 95.986230 (C, atm, Hz, ...) 18:04:58 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090475 V 18:04:58 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090475 (V, A, ohm, ...), Measured Value = 6.785655 (C, atm, Hz, ...) 18:05:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 18:05:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877859 (C, atm, Hz, ...) 18:05:06 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.28 P4 = Left Coil Middle, Value = 28.07 P5 = Ambient, Value = 23.63 P6 = Supply Temp(C), Value = 28.54 P7 = Return Temp(C), Value = 28.96 P8 = Supply Pres(psi), Value = 95.99 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.88 18:05:06 Magnet system MAIN current ramping to 75.0000 A... 18:06:01 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:06:04 Main (V) Voltage Measurement, V = 2.670969 V 18:06:09 Temperature Measurement, Probe Number = 0, T = 26.558000 C 18:06:11 Temperature Measurement, Probe Number = 1, T = 28.025000 C 18:06:13 Temperature Measurement, Probe Number = 2, T = 27.861000 C 18:06:15 Temperature Measurement, Probe Number = 3, T = 23.613000 C 18:06:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334576 V 18:06:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334576 (V, A, ohm, ...), Measured Value = 28.535782 (C, atm, Hz, ...) 18:06:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366667 V 18:06:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366667 (V, A, ohm, ...), Measured Value = 28.981486 (C, atm, Hz, ...) 18:06:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282050 V 18:06:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282050 (V, A, ohm, ...), Measured Value = 96.153728 (C, atm, Hz, ...) 18:06:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090665 V 18:06:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090665 (V, A, ohm, ...), Measured Value = 6.799897 (C, atm, Hz, ...) 18:06:31 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000884 V 18:06:31 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000884 (V, A, ohm, ...), Measured Value = 0.883902 (C, atm, Hz, ...) 18:06:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.02 P4 = Left Coil Middle, Value = 27.86 P5 = Ambient, Value = 23.61 P6 = Supply Temp(C), Value = 28.54 P7 = Return Temp(C), Value = 28.98 P8 = Supply Pres(psi), Value = 96.15 P9 = Return Pres(psi), Value = 6.80 P10 = Flow Rate(gpm), Value = 0.88 18:06:31 Magnetic Field Measurement Measuring the magnet strength... 18:06:31 Integrated Voltage Measurement... 18:06:34 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:06:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402344 Vs 18:06:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396382 Vs 18:06:55 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:07:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402397 Vs 18:07:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397005 Vs 18:07:16 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:07:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403968 Vs 18:07:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397149 Vs 18:07:37 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:07:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401809 Vs 18:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397712 Vs 18:07:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399846 +- 0.000000439 Vs 18:07:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014399846 +- 0.000000439 Vs BL = -0.15999829 +- 0.00000487 Tm 18:07:59 Position moved: 0.000000 m 18:07:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16000 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16000 0.00000 -0.16000 0.00000 18:07:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16000 0.00000 SL = -0.1599983 +- 0.0000049 Tm^2/m^n 18:07:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599983 +- 0.0000049 Tm^2/m^n 18:08:02 Position moved: 0.000000 m 18:08:02 Magnet system MAIN current ramping to 125.0000 A... 18:08:41 Magnet system MAIN current ramping to 0.0000 A... 18:10:03 Magnet system MAIN current ramping to 125.0000 A... 18:11:25 Magnet system MAIN current ramping to 0.0000 A... 18:12:47 Magnet system MAIN current ramping to 125.0000 A... 18:14:09 Magnet system MAIN current ramping to 0.0000 A... 18:15:34 Position moved: 0.000000 m 18:15:37 Magnet system MAIN current ramping to 87.5000 A... 18:16:39 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:16:41 Main (V) Voltage Measurement, V = 3.115574 V 18:16:46 Temperature Measurement, Probe Number = 0, T = 26.552000 C 18:16:48 Temperature Measurement, Probe Number = 1, T = 28.004000 C 18:16:50 Temperature Measurement, Probe Number = 2, T = 27.910000 C 18:16:53 Temperature Measurement, Probe Number = 3, T = 23.518000 C 18:16:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333692 V 18:16:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333692 (V, A, ohm, ...), Measured Value = 28.523493 (C, atm, Hz, ...) 18:16:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359174 V 18:16:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359174 (V, A, ohm, ...), Measured Value = 28.877415 (C, atm, Hz, ...) 18:16:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271103 V 18:16:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271103 (V, A, ohm, ...), Measured Value = 95.332695 (C, atm, Hz, ...) 18:17:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090810 V 18:17:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090810 (V, A, ohm, ...), Measured Value = 6.810750 (C, atm, Hz, ...) 18:17:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 18:17:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877989 (C, atm, Hz, ...) 18:17:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.00 P4 = Left Coil Middle, Value = 27.91 P5 = Ambient, Value = 23.52 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.88 P8 = Supply Pres(psi), Value = 95.33 P9 = Return Pres(psi), Value = 6.81 P10 = Flow Rate(gpm), Value = 0.88 18:17:09 Magnetic Field Measurement Measuring the magnet strength... 18:17:09 Integrated Voltage Measurement... 18:17:11 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:17:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777955 Vs 18:17:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771292 Vs 18:17:33 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:17:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779359 Vs 18:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770836 Vs 18:17:54 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:18:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778549 Vs 18:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771585 Vs 18:18:15 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777202 Vs 18:18:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771314 Vs 18:18:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774762 +- 0.000000346 Vs 18:18:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016774762 +- 0.000000346 Vs BL = -0.18638624 +- 0.00000384 Tm 18:18:37 Position moved: 0.000000 m 18:18:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18639 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18639 0.00000 -0.18639 0.00000 18:18:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18639 0.00000 SL = -0.1863862 +- 0.0000038 Tm^2/m^n 18:18:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863862 +- 0.0000038 Tm^2/m^n 18:18:40 Position moved: 0.000000 m 18:18:40 Magnet system MAIN current ramping to 75.0000 A... 18:19:00 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:19:02 Main (V) Voltage Measurement, V = 2.674025 V 18:19:07 Temperature Measurement, Probe Number = 0, T = 26.536000 C 18:19:09 Temperature Measurement, Probe Number = 1, T = 28.071000 C 18:19:11 Temperature Measurement, Probe Number = 2, T = 28.004000 C 18:19:13 Temperature Measurement, Probe Number = 3, T = 23.506000 C 18:19:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334189 V 18:19:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334189 (V, A, ohm, ...), Measured Value = 28.530400 (C, atm, Hz, ...) 18:19:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352801 V 18:19:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352801 (V, A, ohm, ...), Measured Value = 28.788899 (C, atm, Hz, ...) 18:19:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271635 V 18:19:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271635 (V, A, ohm, ...), Measured Value = 95.372610 (C, atm, Hz, ...) 18:19:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090530 V 18:19:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090530 (V, A, ohm, ...), Measured Value = 6.789728 (C, atm, Hz, ...) 18:19:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 18:19:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885604 (C, atm, Hz, ...) 18:19:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.07 P4 = Left Coil Middle, Value = 28.00 P5 = Ambient, Value = 23.51 P6 = Supply Temp(C), Value = 28.53 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.37 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.89 18:19:30 Magnet system MAIN current ramping to 125.0000 A... 18:20:11 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:20:13 Main (V) Voltage Measurement, V = 4.459339 V 18:20:18 Temperature Measurement, Probe Number = 0, T = 26.528000 C 18:20:20 Temperature Measurement, Probe Number = 1, T = 28.175000 C 18:20:23 Temperature Measurement, Probe Number = 2, T = 28.063000 C 18:20:25 Temperature Measurement, Probe Number = 3, T = 23.490000 C 18:20:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333934 V 18:20:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333934 (V, A, ohm, ...), Measured Value = 28.526865 (C, atm, Hz, ...) 18:20:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355062 V 18:20:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355062 (V, A, ohm, ...), Measured Value = 28.820313 (C, atm, Hz, ...) 18:20:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271462 V 18:20:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271462 (V, A, ohm, ...), Measured Value = 95.359628 (C, atm, Hz, ...) 18:20:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090469 V 18:20:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090469 (V, A, ohm, ...), Measured Value = 6.785175 (C, atm, Hz, ...) 18:20:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 18:20:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892794 (C, atm, Hz, ...) 18:20:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.18 P4 = Left Coil Middle, Value = 28.06 P5 = Ambient, Value = 23.49 P6 = Supply Temp(C), Value = 28.53 P7 = Return Temp(C), Value = 28.82 P8 = Supply Pres(psi), Value = 95.36 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.89 18:20:41 Magnet system MAIN current ramping to 0.0000 A... 18:22:05 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:22:07 Main (V) Voltage Measurement, V = 0.000000 V 18:22:12 Temperature Measurement, Probe Number = 0, T = 26.525000 C 18:22:14 Temperature Measurement, Probe Number = 1, T = 28.318000 C 18:22:16 Temperature Measurement, Probe Number = 2, T = 28.077000 C 18:22:18 Temperature Measurement, Probe Number = 3, T = 23.486000 C 18:22:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334244 V 18:22:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334244 (V, A, ohm, ...), Measured Value = 28.531171 (C, atm, Hz, ...) 18:22:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.364195 V 18:22:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.364195 (V, A, ohm, ...), Measured Value = 28.947149 (C, atm, Hz, ...) 18:22:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276462 V 18:22:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276462 (V, A, ohm, ...), Measured Value = 95.734643 (C, atm, Hz, ...) 18:22:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090536 V 18:22:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090536 (V, A, ohm, ...), Measured Value = 6.790208 (C, atm, Hz, ...) 18:22:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 18:22:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892860 (C, atm, Hz, ...) 18:22:35 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.32 P4 = Left Coil Middle, Value = 28.08 P5 = Ambient, Value = 23.49 P6 = Supply Temp(C), Value = 28.53 P7 = Return Temp(C), Value = 28.95 P8 = Supply Pres(psi), Value = 95.73 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.89 18:22:35 Magnet system MAIN current ramping to 125.0000 A... 18:23:59 Magnet Current for MAIN, Imag = 124.9929 A Vtrans = 1.249928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:24:01 Main (V) Voltage Measurement, V = 4.460220 V 18:24:06 Temperature Measurement, Probe Number = 0, T = 26.533000 C 18:24:08 Temperature Measurement, Probe Number = 1, T = 28.087000 C 18:24:10 Temperature Measurement, Probe Number = 2, T = 27.981000 C 18:24:12 Temperature Measurement, Probe Number = 3, T = 23.505000 C 18:24:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334357 V 18:24:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334357 (V, A, ohm, ...), Measured Value = 28.532732 (C, atm, Hz, ...) 18:24:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361636 V 18:24:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361636 (V, A, ohm, ...), Measured Value = 28.911610 (C, atm, Hz, ...) 18:24:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275177 V 18:24:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275177 (V, A, ohm, ...), Measured Value = 95.638245 (C, atm, Hz, ...) 18:24:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090599 V 18:24:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090599 (V, A, ohm, ...), Measured Value = 6.794955 (C, atm, Hz, ...) 18:24:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 18:24:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.882889 (C, atm, Hz, ...) 18:24:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.09 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.50 P6 = Supply Temp(C), Value = 28.53 P7 = Return Temp(C), Value = 28.91 P8 = Supply Pres(psi), Value = 95.64 P9 = Return Pres(psi), Value = 6.79 P10 = Flow Rate(gpm), Value = 0.88 18:24:29 Magnet system MAIN current ramping to 0.0000 A... 18:25:53 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:25:55 Main (V) Voltage Measurement, V = 0.000001 V 18:26:00 Temperature Measurement, Probe Number = 0, T = 26.532000 C 18:26:03 Temperature Measurement, Probe Number = 1, T = 28.257000 C 18:26:05 Temperature Measurement, Probe Number = 2, T = 28.047000 C 18:26:07 Temperature Measurement, Probe Number = 3, T = 23.500000 C 18:26:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334521 V 18:26:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334521 (V, A, ohm, ...), Measured Value = 28.535011 (C, atm, Hz, ...) 18:26:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362911 V 18:26:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362911 (V, A, ohm, ...), Measured Value = 28.929317 (C, atm, Hz, ...) 18:26:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278091 V 18:26:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278091 (V, A, ohm, ...), Measured Value = 95.856802 (C, atm, Hz, ...) 18:26:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090677 V 18:26:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090677 (V, A, ohm, ...), Measured Value = 6.800768 (C, atm, Hz, ...) 18:26:23 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000879 V 18:26:23 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000879 (V, A, ohm, ...), Measured Value = 0.879121 (C, atm, Hz, ...) 18:26:23 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 28.05 P5 = Ambient, Value = 23.50 P6 = Supply Temp(C), Value = 28.54 P7 = Return Temp(C), Value = 28.93 P8 = Supply Pres(psi), Value = 95.86 P9 = Return Pres(psi), Value = 6.80 P10 = Flow Rate(gpm), Value = 0.88 18:26:23 Magnet system MAIN current ramping to 125.0000 A... 18:27:47 Magnet Current for MAIN, Imag = 124.9937 A Vtrans = 1.249936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:27:49 Main (V) Voltage Measurement, V = 4.459883 V 18:27:54 Temperature Measurement, Probe Number = 0, T = 26.539000 C 18:27:56 Temperature Measurement, Probe Number = 1, T = 28.056000 C 18:27:58 Temperature Measurement, Probe Number = 2, T = 27.960000 C 18:28:01 Temperature Measurement, Probe Number = 3, T = 23.456000 C 18:28:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333598 V 18:28:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333598 (V, A, ohm, ...), Measured Value = 28.522201 (C, atm, Hz, ...) 18:28:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361273 V 18:28:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361273 (V, A, ohm, ...), Measured Value = 28.906568 (C, atm, Hz, ...) 18:28:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263951 V 18:28:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263951 (V, A, ohm, ...), Measured Value = 94.796295 (C, atm, Hz, ...) 18:28:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090968 V 18:28:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090968 (V, A, ohm, ...), Measured Value = 6.822570 (C, atm, Hz, ...) 18:28:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 18:28:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.887135 (C, atm, Hz, ...) 18:28:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.96 P5 = Ambient, Value = 23.46 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.91 P8 = Supply Pres(psi), Value = 94.80 P9 = Return Pres(psi), Value = 6.82 P10 = Flow Rate(gpm), Value = 0.89 18:28:17 Magnet system MAIN current ramping to 0.0000 A... 18:29:41 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:29:43 Main (V) Voltage Measurement, V = -0.000001 V 18:29:48 Temperature Measurement, Probe Number = 0, T = 26.549000 C 18:29:50 Temperature Measurement, Probe Number = 1, T = 28.269000 C 18:29:52 Temperature Measurement, Probe Number = 2, T = 28.053000 C 18:29:54 Temperature Measurement, Probe Number = 3, T = 23.447000 C 18:29:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333686 V 18:29:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333686 (V, A, ohm, ...), Measured Value = 28.523421 (C, atm, Hz, ...) 18:29:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362390 V 18:29:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362390 (V, A, ohm, ...), Measured Value = 28.922086 (C, atm, Hz, ...) 18:30:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270062 V 18:30:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270062 (V, A, ohm, ...), Measured Value = 95.254613 (C, atm, Hz, ...) 18:30:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090651 V 18:30:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090651 (V, A, ohm, ...), Measured Value = 6.798833 (C, atm, Hz, ...) 18:30:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 18:30:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887792 (C, atm, Hz, ...) 18:30:11 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.27 P4 = Left Coil Middle, Value = 28.05 P5 = Ambient, Value = 23.45 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.25 P9 = Return Pres(psi), Value = 6.80 P10 = Flow Rate(gpm), Value = 0.89 18:30:11 Magnet system MAIN current ramping to 125.0000 A... 18:31:34 Magnet Current for MAIN, Imag = 124.9910 A Vtrans = 1.249909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:31:36 Main (V) Voltage Measurement, V = 4.459845 V 18:31:41 Temperature Measurement, Probe Number = 0, T = 26.539000 C 18:31:43 Temperature Measurement, Probe Number = 1, T = 28.054000 C 18:31:45 Temperature Measurement, Probe Number = 2, T = 27.958000 C 18:31:48 Temperature Measurement, Probe Number = 3, T = 23.436000 C 18:31:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333747 V 18:31:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333747 (V, A, ohm, ...), Measured Value = 28.524264 (C, atm, Hz, ...) 18:31:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361008 V 18:31:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361008 (V, A, ohm, ...), Measured Value = 28.902890 (C, atm, Hz, ...) 18:31:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272981 V 18:31:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272981 (V, A, ohm, ...), Measured Value = 95.473560 (C, atm, Hz, ...) 18:31:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091101 V 18:31:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091101 (V, A, ohm, ...), Measured Value = 6.832545 (C, atm, Hz, ...) 18:32:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 18:32:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886416 (C, atm, Hz, ...) 18:32:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.05 P4 = Left Coil Middle, Value = 27.96 P5 = Ambient, Value = 23.44 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.90 P8 = Supply Pres(psi), Value = 95.47 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.89 18:32:04 Magnet system MAIN current ramping to 0.0000 A... 18:33:28 Magnet Current for MAIN, Imag = -0.0007 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:33:30 Main (V) Voltage Measurement, V = 0.000003 V 18:33:35 Temperature Measurement, Probe Number = 0, T = 26.528000 C 18:33:37 Temperature Measurement, Probe Number = 1, T = 28.274000 C 18:33:39 Temperature Measurement, Probe Number = 2, T = 28.057000 C 18:33:42 Temperature Measurement, Probe Number = 3, T = 23.424000 C 18:33:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333535 V 18:33:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333535 (V, A, ohm, ...), Measured Value = 28.521322 (C, atm, Hz, ...) 18:33:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362129 V 18:33:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362129 (V, A, ohm, ...), Measured Value = 28.918463 (C, atm, Hz, ...) 18:33:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281024 V 18:33:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281024 (V, A, ohm, ...), Measured Value = 96.076808 (C, atm, Hz, ...) 18:33:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090716 V 18:33:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090716 (V, A, ohm, ...), Measured Value = 6.803678 (C, atm, Hz, ...) 18:33:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 18:33:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.894667 (C, atm, Hz, ...) 18:33:58 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.27 P4 = Left Coil Middle, Value = 28.06 P5 = Ambient, Value = 23.42 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 96.08 P9 = Return Pres(psi), Value = 6.80 P10 = Flow Rate(gpm), Value = 0.89 18:33:58 Magnet system MAIN current ramping to 75.0000 A... 18:34:54 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:34:56 Main (V) Voltage Measurement, V = 2.670748 V 18:35:01 Temperature Measurement, Probe Number = 0, T = 26.528000 C 18:35:03 Temperature Measurement, Probe Number = 1, T = 28.037000 C 18:35:05 Temperature Measurement, Probe Number = 2, T = 27.823000 C 18:35:07 Temperature Measurement, Probe Number = 3, T = 23.399000 C 18:35:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334157 V 18:35:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334157 (V, A, ohm, ...), Measured Value = 28.529951 (C, atm, Hz, ...) 18:35:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.364177 V 18:35:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.364177 (V, A, ohm, ...), Measured Value = 28.946897 (C, atm, Hz, ...) 18:35:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277685 V 18:35:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277685 (V, A, ohm, ...), Measured Value = 95.826382 (C, atm, Hz, ...) 18:35:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090735 V 18:35:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090735 (V, A, ohm, ...), Measured Value = 6.805133 (C, atm, Hz, ...) 18:35:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 18:35:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878352 (C, atm, Hz, ...) 18:35:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.04 P4 = Left Coil Middle, Value = 27.82 P5 = Ambient, Value = 23.40 P6 = Supply Temp(C), Value = 28.53 P7 = Return Temp(C), Value = 28.95 P8 = Supply Pres(psi), Value = 95.83 P9 = Return Pres(psi), Value = 6.81 P10 = Flow Rate(gpm), Value = 0.88 18:35:24 Magnetic Field Measurement Measuring the magnet strength... 18:35:24 Integrated Voltage Measurement... 18:35:26 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401747 Vs 18:35:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400216 Vs 18:35:48 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:35:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400312 Vs 18:36:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400529 Vs 18:36:08 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:36:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402679 Vs 18:36:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398796 Vs 18:36:29 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:36:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402602 Vs 18:36:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399277 Vs 18:36:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400770 +- 0.000000222 Vs 18:36:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014400770 +- 0.000000222 Vs BL = -0.16000855 +- 0.00000246 Tm 18:36:52 Position moved: 0.000000 m 18:36:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00000 -0.16001 0.00000 18:36:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00000 SL = -0.1600086 +- 0.0000025 Tm^2/m^n 18:36:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600086 +- 0.0000025 Tm^2/m^n 18:36:55 Position moved: 0.000000 m 18:36:55 Magnet system MAIN current ramping to 125.0000 A... 18:37:34 Magnet system MAIN current ramping to 0.0000 A... 18:38:57 Magnet system MAIN current ramping to 125.0000 A... 18:40:18 Magnet system MAIN current ramping to 0.0000 A... 18:41:41 Magnet system MAIN current ramping to 125.0000 A... 18:43:03 Magnet system MAIN current ramping to 0.0000 A... 18:44:28 Position moved: 0.000000 m 18:44:30 Magnet system MAIN current ramping to 87.5000 A... 18:45:33 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:45:35 Main (V) Voltage Measurement, V = 3.115341 V 18:45:40 Temperature Measurement, Probe Number = 0, T = 26.511000 C 18:45:43 Temperature Measurement, Probe Number = 1, T = 28.041000 C 18:45:45 Temperature Measurement, Probe Number = 2, T = 27.842000 C 18:45:47 Temperature Measurement, Probe Number = 3, T = 23.393000 C 18:45:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332763 V 18:45:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332763 (V, A, ohm, ...), Measured Value = 28.510594 (C, atm, Hz, ...) 18:45:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.357534 V 18:45:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.357534 (V, A, ohm, ...), Measured Value = 28.854632 (C, atm, Hz, ...) 18:45:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267995 V 18:45:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267995 (V, A, ohm, ...), Measured Value = 95.099610 (C, atm, Hz, ...) 18:45:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090946 V 18:45:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090946 (V, A, ohm, ...), Measured Value = 6.820920 (C, atm, Hz, ...) 18:46:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 18:46:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.888825 (C, atm, Hz, ...) 18:46:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.04 P4 = Left Coil Middle, Value = 27.84 P5 = Ambient, Value = 23.39 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.85 P8 = Supply Pres(psi), Value = 95.10 P9 = Return Pres(psi), Value = 6.82 P10 = Flow Rate(gpm), Value = 0.89 18:46:03 Magnetic Field Measurement Measuring the magnet strength... 18:46:03 Integrated Voltage Measurement... 18:46:05 Magnet Current for MAIN, Imag = 87.4694 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:46:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773772 Vs 18:46:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771534 Vs 18:46:27 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778256 Vs 18:46:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770978 Vs 18:46:48 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:46:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778849 Vs 18:47:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771616 Vs 18:47:09 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773906 Vs 18:47:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775958 Vs 18:47:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774359 +- 0.000001008 Vs 18:47:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016774359 +- 0.000001008 Vs BL = -0.18638176 +- 0.00001120 Tm 18:47:32 Position moved: 0.000000 m 18:47:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18638 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18638 0.00001 -0.18638 0.00000 18:47:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18638 0.00001 SL = -0.1863818 +- 0.0000112 Tm^2/m^n 18:47:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863818 +- 0.0000112 Tm^2/m^n 18:47:34 Position moved: 0.000000 m 18:47:34 Magnet system MAIN current ramping to 75.0000 A... 18:47:55 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:47:57 Main (V) Voltage Measurement, V = 2.673825 V 18:48:02 Temperature Measurement, Probe Number = 0, T = 26.501000 C 18:48:04 Temperature Measurement, Probe Number = 1, T = 28.100000 C 18:48:06 Temperature Measurement, Probe Number = 2, T = 27.975000 C 18:48:08 Temperature Measurement, Probe Number = 3, T = 23.362000 C 18:48:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333088 V 18:48:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333088 (V, A, ohm, ...), Measured Value = 28.515115 (C, atm, Hz, ...) 18:48:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.350852 V 18:48:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350852 (V, A, ohm, ...), Measured Value = 28.761828 (C, atm, Hz, ...) 18:48:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.282993 V 18:48:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.282993 (V, A, ohm, ...), Measured Value = 96.224445 (C, atm, Hz, ...) 18:48:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090922 V 18:48:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090922 (V, A, ohm, ...), Measured Value = 6.819180 (C, atm, Hz, ...) 18:48:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 18:48:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900387 (C, atm, Hz, ...) 18:48:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.10 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.36 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.76 P8 = Supply Pres(psi), Value = 96.22 P9 = Return Pres(psi), Value = 6.82 P10 = Flow Rate(gpm), Value = 0.90 18:48:25 Magnet system MAIN current ramping to 125.0000 A... 18:49:06 Magnet Current for MAIN, Imag = 124.9926 A Vtrans = 1.249925 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:49:08 Main (V) Voltage Measurement, V = 4.459090 V 18:49:14 Temperature Measurement, Probe Number = 0, T = 26.514000 C 18:49:16 Temperature Measurement, Probe Number = 1, T = 28.136000 C 18:49:18 Temperature Measurement, Probe Number = 2, T = 27.994000 C 18:49:20 Temperature Measurement, Probe Number = 3, T = 23.354000 C 18:49:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333028 V 18:49:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333028 (V, A, ohm, ...), Measured Value = 28.514272 (C, atm, Hz, ...) 18:49:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353270 V 18:49:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353270 (V, A, ohm, ...), Measured Value = 28.795411 (C, atm, Hz, ...) 18:49:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280351 V 18:49:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280351 (V, A, ohm, ...), Measured Value = 96.026332 (C, atm, Hz, ...) 18:49:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090822 V 18:49:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090822 (V, A, ohm, ...), Measured Value = 6.811620 (C, atm, Hz, ...) 18:49:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 18:49:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893204 (C, atm, Hz, ...) 18:49:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.14 P4 = Left Coil Middle, Value = 27.99 P5 = Ambient, Value = 23.35 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.80 P8 = Supply Pres(psi), Value = 96.03 P9 = Return Pres(psi), Value = 6.81 P10 = Flow Rate(gpm), Value = 0.89 18:49:36 Magnet system MAIN current ramping to 0.0000 A... 18:51:00 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:51:02 Main (V) Voltage Measurement, V = -0.000001 V 18:51:07 Temperature Measurement, Probe Number = 0, T = 26.510000 C 18:51:09 Temperature Measurement, Probe Number = 1, T = 28.288000 C 18:51:12 Temperature Measurement, Probe Number = 2, T = 28.022000 C 18:51:14 Temperature Measurement, Probe Number = 3, T = 23.344000 C 18:51:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333131 V 18:51:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333131 (V, A, ohm, ...), Measured Value = 28.515707 (C, atm, Hz, ...) 18:51:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362379 V 18:51:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362379 (V, A, ohm, ...), Measured Value = 28.921925 (C, atm, Hz, ...) 18:51:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273092 V 18:51:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273092 (V, A, ohm, ...), Measured Value = 95.481885 (C, atm, Hz, ...) 18:51:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091097 V 18:51:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091097 (V, A, ohm, ...), Measured Value = 6.832253 (C, atm, Hz, ...) 18:51:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000870 V 18:51:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000870 (V, A, ohm, ...), Measured Value = 0.869970 (C, atm, Hz, ...) 18:51:30 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.29 P4 = Left Coil Middle, Value = 28.02 P5 = Ambient, Value = 23.34 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.48 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.87 18:51:30 Magnet system MAIN current ramping to 125.0000 A... 18:52:55 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:52:57 Main (V) Voltage Measurement, V = 4.459757 V 18:53:02 Temperature Measurement, Probe Number = 0, T = 26.503000 C 18:53:04 Temperature Measurement, Probe Number = 1, T = 28.081000 C 18:53:06 Temperature Measurement, Probe Number = 2, T = 27.941000 C 18:53:08 Temperature Measurement, Probe Number = 3, T = 23.367000 C 18:53:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332959 V 18:53:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332959 (V, A, ohm, ...), Measured Value = 28.513321 (C, atm, Hz, ...) 18:53:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359458 V 18:53:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359458 (V, A, ohm, ...), Measured Value = 28.881362 (C, atm, Hz, ...) 18:53:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272298 V 18:53:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272298 (V, A, ohm, ...), Measured Value = 95.422313 (C, atm, Hz, ...) 18:53:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.090935 V 18:53:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.090935 (V, A, ohm, ...), Measured Value = 6.820147 (C, atm, Hz, ...) 18:53:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 18:53:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900500 (C, atm, Hz, ...) 18:53:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.08 P4 = Left Coil Middle, Value = 27.94 P5 = Ambient, Value = 23.37 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.88 P8 = Supply Pres(psi), Value = 95.42 P9 = Return Pres(psi), Value = 6.82 P10 = Flow Rate(gpm), Value = 0.90 18:53:25 Magnet system MAIN current ramping to 0.0000 A... 18:54:48 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:54:51 Main (V) Voltage Measurement, V = -0.000004 V 18:54:56 Temperature Measurement, Probe Number = 0, T = 26.493000 C 18:54:58 Temperature Measurement, Probe Number = 1, T = 28.296000 C 18:55:00 Temperature Measurement, Probe Number = 2, T = 28.010000 C 18:55:02 Temperature Measurement, Probe Number = 3, T = 23.327000 C 18:55:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333272 V 18:55:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333272 (V, A, ohm, ...), Measured Value = 28.517663 (C, atm, Hz, ...) 18:55:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.360189 V 18:55:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360189 (V, A, ohm, ...), Measured Value = 28.891517 (C, atm, Hz, ...) 18:55:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271754 V 18:55:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271754 (V, A, ohm, ...), Measured Value = 95.381528 (C, atm, Hz, ...) 18:55:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091124 V 18:55:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091124 (V, A, ohm, ...), Measured Value = 6.834292 (C, atm, Hz, ...) 18:55:18 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000894 V 18:55:18 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000894 (V, A, ohm, ...), Measured Value = 0.893911 (C, atm, Hz, ...) 18:55:18 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.49 P3 = Right Coil Outgoing Side, Value = 28.30 P4 = Left Coil Middle, Value = 28.01 P5 = Ambient, Value = 23.33 P6 = Supply Temp(C), Value = 28.52 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 95.38 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.89 18:55:18 Magnet system MAIN current ramping to 125.0000 A... 18:56:42 Magnet Current for MAIN, Imag = 124.9894 A Vtrans = 1.249893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:56:45 Main (V) Voltage Measurement, V = 4.459778 V 18:56:50 Temperature Measurement, Probe Number = 0, T = 26.489000 C 18:56:52 Temperature Measurement, Probe Number = 1, T = 28.086000 C 18:56:54 Temperature Measurement, Probe Number = 2, T = 27.931000 C 18:56:56 Temperature Measurement, Probe Number = 3, T = 23.370000 C 18:56:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332708 V 18:56:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332708 (V, A, ohm, ...), Measured Value = 28.509840 (C, atm, Hz, ...) 18:57:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358971 V 18:57:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358971 (V, A, ohm, ...), Measured Value = 28.874599 (C, atm, Hz, ...) 18:57:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279836 V 18:57:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279836 (V, A, ohm, ...), Measured Value = 95.987678 (C, atm, Hz, ...) 18:57:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091132 V 18:57:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091132 (V, A, ohm, ...), Measured Value = 6.834870 (C, atm, Hz, ...) 18:57:12 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 18:57:12 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890948 (C, atm, Hz, ...) 18:57:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.49 P3 = Right Coil Outgoing Side, Value = 28.09 P4 = Left Coil Middle, Value = 27.93 P5 = Ambient, Value = 23.37 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.87 P8 = Supply Pres(psi), Value = 95.99 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.89 18:57:12 Magnet system MAIN current ramping to 0.0000 A... 18:58:37 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 18:58:39 Main (V) Voltage Measurement, V = -0.000004 V 18:58:44 Temperature Measurement, Probe Number = 0, T = 26.498000 C 18:58:46 Temperature Measurement, Probe Number = 1, T = 28.229000 C 18:58:48 Temperature Measurement, Probe Number = 2, T = 27.982000 C 18:58:50 Temperature Measurement, Probe Number = 3, T = 23.318000 C 18:58:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332268 V 18:58:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332268 (V, A, ohm, ...), Measured Value = 28.503724 (C, atm, Hz, ...) 18:58:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.360405 V 18:58:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.360405 (V, A, ohm, ...), Measured Value = 28.894512 (C, atm, Hz, ...) 18:58:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277885 V 18:58:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277885 (V, A, ohm, ...), Measured Value = 95.841397 (C, atm, Hz, ...) 18:58:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091168 V 18:58:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091168 (V, A, ohm, ...), Measured Value = 6.837585 (C, atm, Hz, ...) 18:59:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 18:59:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893453 (C, atm, Hz, ...) 18:59:07 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.23 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.32 P6 = Supply Temp(C), Value = 28.50 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 95.84 P9 = Return Pres(psi), Value = 6.84 P10 = Flow Rate(gpm), Value = 0.89 18:59:07 Magnet system MAIN current ramping to 125.0000 A... 19:00:31 Magnet Current for MAIN, Imag = 124.9924 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:00:33 Main (V) Voltage Measurement, V = 4.459465 V 19:00:38 Temperature Measurement, Probe Number = 0, T = 26.498000 C 19:00:40 Temperature Measurement, Probe Number = 1, T = 28.042000 C 19:00:42 Temperature Measurement, Probe Number = 2, T = 27.930000 C 19:00:44 Temperature Measurement, Probe Number = 3, T = 23.316000 C 19:00:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332619 V 19:00:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332619 (V, A, ohm, ...), Measured Value = 28.508603 (C, atm, Hz, ...) 19:00:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358885 V 19:00:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358885 (V, A, ohm, ...), Measured Value = 28.873397 (C, atm, Hz, ...) 19:00:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.269735 V 19:00:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.269735 (V, A, ohm, ...), Measured Value = 95.230102 (C, atm, Hz, ...) 19:00:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091203 V 19:00:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091203 (V, A, ohm, ...), Measured Value = 6.840195 (C, atm, Hz, ...) 19:01:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 19:01:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885473 (C, atm, Hz, ...) 19:01:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.04 P4 = Left Coil Middle, Value = 27.93 P5 = Ambient, Value = 23.32 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.87 P8 = Supply Pres(psi), Value = 95.23 P9 = Return Pres(psi), Value = 6.84 P10 = Flow Rate(gpm), Value = 0.89 19:01:00 Magnet system MAIN current ramping to 0.0000 A... 19:02:24 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:02:26 Main (V) Voltage Measurement, V = 0.000003 V 19:02:31 Temperature Measurement, Probe Number = 0, T = 26.506000 C 19:02:33 Temperature Measurement, Probe Number = 1, T = 28.251000 C 19:02:35 Temperature Measurement, Probe Number = 2, T = 28.020000 C 19:02:37 Temperature Measurement, Probe Number = 3, T = 23.331000 C 19:02:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332728 V 19:02:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332728 (V, A, ohm, ...), Measured Value = 28.510110 (C, atm, Hz, ...) 19:02:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359888 V 19:02:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359888 (V, A, ohm, ...), Measured Value = 28.887336 (C, atm, Hz, ...) 19:02:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277423 V 19:02:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277423 (V, A, ohm, ...), Measured Value = 95.806717 (C, atm, Hz, ...) 19:02:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091173 V 19:02:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091173 (V, A, ohm, ...), Measured Value = 6.837967 (C, atm, Hz, ...) 19:02:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000876 V 19:02:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000876 (V, A, ohm, ...), Measured Value = 0.875637 (C, atm, Hz, ...) 19:02:54 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.51 P3 = Right Coil Outgoing Side, Value = 28.25 P4 = Left Coil Middle, Value = 28.02 P5 = Ambient, Value = 23.33 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 95.81 P9 = Return Pres(psi), Value = 6.84 P10 = Flow Rate(gpm), Value = 0.88 19:02:54 Magnet system MAIN current ramping to 75.0000 A... 19:03:49 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:03:52 Main (V) Voltage Measurement, V = 2.670666 V 19:03:57 Temperature Measurement, Probe Number = 0, T = 26.504000 C 19:03:59 Temperature Measurement, Probe Number = 1, T = 28.008000 C 19:04:01 Temperature Measurement, Probe Number = 2, T = 27.815000 C 19:04:03 Temperature Measurement, Probe Number = 3, T = 23.364000 C 19:04:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333070 V 19:04:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333070 (V, A, ohm, ...), Measured Value = 28.514864 (C, atm, Hz, ...) 19:04:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362169 V 19:04:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362169 (V, A, ohm, ...), Measured Value = 28.919018 (C, atm, Hz, ...) 19:04:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273226 V 19:04:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273226 (V, A, ohm, ...), Measured Value = 95.491965 (C, atm, Hz, ...) 19:04:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091386 V 19:04:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091386 (V, A, ohm, ...), Measured Value = 6.853958 (C, atm, Hz, ...) 19:04:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 19:04:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.886524 (C, atm, Hz, ...) 19:04:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.01 P4 = Left Coil Middle, Value = 27.82 P5 = Ambient, Value = 23.36 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.49 P9 = Return Pres(psi), Value = 6.85 P10 = Flow Rate(gpm), Value = 0.89 19:04:19 Magnetic Field Measurement Measuring the magnet strength... 19:04:19 Integrated Voltage Measurement... 19:04:22 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402676 Vs 19:04:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399395 Vs 19:04:44 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404940 Vs 19:05:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397511 Vs 19:05:04 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406309 Vs 19:05:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397218 Vs 19:05:25 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:05:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405885 Vs 19:05:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401164 Vs 19:05:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401887 +- 0.000000982 Vs 19:05:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401887 +- 0.000000982 Vs BL = -0.16002097 +- 0.00001091 Tm 19:05:48 Position moved: 0.000000 m 19:05:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16002 0.00001 -0.16002 0.00000 19:05:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16002 0.00001 SL = -0.1600210 +- 0.0000109 Tm^2/m^n 19:05:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600210 +- 0.0000109 Tm^2/m^n 19:05:51 Position moved: 0.000000 m 19:05:51 Magnet system MAIN current ramping to 125.0000 A... 19:06:30 Magnet system MAIN current ramping to 0.0000 A... 19:07:51 Magnet system MAIN current ramping to 125.0000 A... 19:09:12 Magnet system MAIN current ramping to 0.0000 A... 19:10:35 Magnet system MAIN current ramping to 125.0000 A... 19:11:57 Magnet system MAIN current ramping to 0.0000 A... 19:13:21 Position moved: 0.000000 m 19:13:24 Magnet system MAIN current ramping to 87.5000 A... 19:14:26 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:14:29 Main (V) Voltage Measurement, V = 3.115331 V 19:14:34 Temperature Measurement, Probe Number = 0, T = 26.474000 C 19:14:36 Temperature Measurement, Probe Number = 1, T = 28.079000 C 19:14:38 Temperature Measurement, Probe Number = 2, T = 27.905000 C 19:14:40 Temperature Measurement, Probe Number = 3, T = 23.280000 C 19:14:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332679 V 19:14:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332679 (V, A, ohm, ...), Measured Value = 28.509428 (C, atm, Hz, ...) 19:14:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355861 V 19:14:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355861 (V, A, ohm, ...), Measured Value = 28.831399 (C, atm, Hz, ...) 19:14:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.280175 V 19:14:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.280175 (V, A, ohm, ...), Measured Value = 96.013162 (C, atm, Hz, ...) 19:14:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091114 V 19:14:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091114 (V, A, ohm, ...), Measured Value = 6.833513 (C, atm, Hz, ...) 19:14:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 19:14:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888253 (C, atm, Hz, ...) 19:14:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.08 P4 = Left Coil Middle, Value = 27.91 P5 = Ambient, Value = 23.28 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 96.01 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.89 19:14:56 Magnetic Field Measurement Measuring the magnet strength... 19:14:56 Integrated Voltage Measurement... 19:14:59 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:15:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774324 Vs 19:15:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775385 Vs 19:15:20 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:15:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775263 Vs 19:15:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775225 Vs 19:15:41 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:15:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773367 Vs 19:16:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777365 Vs 19:16:02 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:16:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776540 Vs 19:16:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775860 Vs 19:16:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775416 +- 0.000000491 Vs 19:16:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016775416 +- 0.000000491 Vs BL = -0.18639351 +- 0.00000545 Tm 19:16:24 Position moved: 0.000000 m 19:16:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18639 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18639 0.00001 -0.18639 0.00000 19:16:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18639 0.00001 SL = -0.1863935 +- 0.0000055 Tm^2/m^n 19:16:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863935 +- 0.0000055 Tm^2/m^n 19:16:27 Position moved: 0.000000 m 19:16:27 Magnet system MAIN current ramping to 75.0000 A... 19:16:47 Magnet Current for MAIN, Imag = 75.0224 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:16:49 Main (V) Voltage Measurement, V = 2.673770 V 19:16:54 Temperature Measurement, Probe Number = 0, T = 26.482000 C 19:16:56 Temperature Measurement, Probe Number = 1, T = 28.122000 C 19:16:58 Temperature Measurement, Probe Number = 2, T = 27.998000 C 19:17:00 Temperature Measurement, Probe Number = 3, T = 23.278000 C 19:17:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332470 V 19:17:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332470 (V, A, ohm, ...), Measured Value = 28.506522 (C, atm, Hz, ...) 19:17:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.349645 V 19:17:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349645 (V, A, ohm, ...), Measured Value = 28.745071 (C, atm, Hz, ...) 19:17:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270502 V 19:17:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270502 (V, A, ohm, ...), Measured Value = 95.287650 (C, atm, Hz, ...) 19:17:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091183 V 19:17:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091183 (V, A, ohm, ...), Measured Value = 6.838747 (C, atm, Hz, ...) 19:17:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 19:17:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892691 (C, atm, Hz, ...) 19:17:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.48 P3 = Right Coil Outgoing Side, Value = 28.12 P4 = Left Coil Middle, Value = 28.00 P5 = Ambient, Value = 23.28 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.75 P8 = Supply Pres(psi), Value = 95.29 P9 = Return Pres(psi), Value = 6.84 P10 = Flow Rate(gpm), Value = 0.89 19:17:17 Magnet system MAIN current ramping to 125.0000 A... 19:17:58 Magnet Current for MAIN, Imag = 124.9922 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:18:01 Main (V) Voltage Measurement, V = 4.459000 V 19:18:06 Temperature Measurement, Probe Number = 0, T = 26.469000 C 19:18:08 Temperature Measurement, Probe Number = 1, T = 28.186000 C 19:18:10 Temperature Measurement, Probe Number = 2, T = 28.045000 C 19:18:12 Temperature Measurement, Probe Number = 3, T = 23.251000 C 19:18:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332256 V 19:18:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332256 (V, A, ohm, ...), Measured Value = 28.503561 (C, atm, Hz, ...) 19:18:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352315 V 19:18:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352315 (V, A, ohm, ...), Measured Value = 28.782154 (C, atm, Hz, ...) 19:18:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273362 V 19:18:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273362 (V, A, ohm, ...), Measured Value = 95.502135 (C, atm, Hz, ...) 19:18:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091090 V 19:18:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091090 (V, A, ohm, ...), Measured Value = 6.831773 (C, atm, Hz, ...) 19:18:28 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 19:18:28 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885075 (C, atm, Hz, ...) 19:18:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.19 P4 = Left Coil Middle, Value = 28.05 P5 = Ambient, Value = 23.25 P6 = Supply Temp(C), Value = 28.50 P7 = Return Temp(C), Value = 28.78 P8 = Supply Pres(psi), Value = 95.50 P9 = Return Pres(psi), Value = 6.83 P10 = Flow Rate(gpm), Value = 0.89 19:18:28 Magnet system MAIN current ramping to 0.0000 A... 19:19:52 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:19:54 Main (V) Voltage Measurement, V = -0.000003 V 19:20:00 Temperature Measurement, Probe Number = 0, T = 26.457000 C 19:20:02 Temperature Measurement, Probe Number = 1, T = 28.318000 C 19:20:04 Temperature Measurement, Probe Number = 2, T = 28.045000 C 19:20:06 Temperature Measurement, Probe Number = 3, T = 23.273000 C 19:20:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332466 V 19:20:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332466 (V, A, ohm, ...), Measured Value = 28.506468 (C, atm, Hz, ...) 19:20:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.361276 V 19:20:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.361276 (V, A, ohm, ...), Measured Value = 28.906604 (C, atm, Hz, ...) 19:20:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276829 V 19:20:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276829 (V, A, ohm, ...), Measured Value = 95.762152 (C, atm, Hz, ...) 19:20:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091567 V 19:20:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091567 (V, A, ohm, ...), Measured Value = 6.867517 (C, atm, Hz, ...) 19:20:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 19:20:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890224 (C, atm, Hz, ...) 19:20:22 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.46 P3 = Right Coil Outgoing Side, Value = 28.32 P4 = Left Coil Middle, Value = 28.05 P5 = Ambient, Value = 23.27 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.91 P8 = Supply Pres(psi), Value = 95.76 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.89 19:20:22 Magnet system MAIN current ramping to 125.0000 A... 19:21:46 Magnet Current for MAIN, Imag = 124.9959 A Vtrans = 1.249958 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:21:48 Main (V) Voltage Measurement, V = 4.459403 V 19:21:53 Temperature Measurement, Probe Number = 0, T = 26.467000 C 19:21:55 Temperature Measurement, Probe Number = 1, T = 28.079000 C 19:21:57 Temperature Measurement, Probe Number = 2, T = 27.926000 C 19:21:59 Temperature Measurement, Probe Number = 3, T = 23.293000 C 19:22:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332410 V 19:22:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332410 (V, A, ohm, ...), Measured Value = 28.505696 (C, atm, Hz, ...) 19:22:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358314 V 19:22:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358314 (V, A, ohm, ...), Measured Value = 28.865468 (C, atm, Hz, ...) 19:22:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273486 V 19:22:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273486 (V, A, ohm, ...), Measured Value = 95.511435 (C, atm, Hz, ...) 19:22:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091580 V 19:22:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091580 (V, A, ohm, ...), Measured Value = 6.868485 (C, atm, Hz, ...) 19:22:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000884 V 19:22:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000884 (V, A, ohm, ...), Measured Value = 0.883777 (C, atm, Hz, ...) 19:22:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.08 P4 = Left Coil Middle, Value = 27.93 P5 = Ambient, Value = 23.29 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.87 P8 = Supply Pres(psi), Value = 95.51 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.88 19:22:16 Magnet system MAIN current ramping to 0.0000 A... 19:23:40 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:23:42 Main (V) Voltage Measurement, V = -0.000003 V 19:23:47 Temperature Measurement, Probe Number = 0, T = 26.463000 C 19:23:49 Temperature Measurement, Probe Number = 1, T = 28.261000 C 19:23:51 Temperature Measurement, Probe Number = 2, T = 28.023000 C 19:23:53 Temperature Measurement, Probe Number = 3, T = 23.253000 C 19:23:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332817 V 19:23:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332817 (V, A, ohm, ...), Measured Value = 28.511347 (C, atm, Hz, ...) 19:23:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359683 V 19:23:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359683 (V, A, ohm, ...), Measured Value = 28.884483 (C, atm, Hz, ...) 19:24:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264127 V 19:24:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264127 (V, A, ohm, ...), Measured Value = 94.809562 (C, atm, Hz, ...) 19:24:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091258 V 19:24:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091258 (V, A, ohm, ...), Measured Value = 6.844365 (C, atm, Hz, ...) 19:24:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 19:24:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892676 (C, atm, Hz, ...) 19:24:10 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.46 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 28.02 P5 = Ambient, Value = 23.25 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.88 P8 = Supply Pres(psi), Value = 94.81 P9 = Return Pres(psi), Value = 6.84 P10 = Flow Rate(gpm), Value = 0.89 19:24:10 Magnet system MAIN current ramping to 125.0000 A... 19:25:33 Magnet Current for MAIN, Imag = 124.9975 A Vtrans = 1.249974 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:25:35 Main (V) Voltage Measurement, V = 4.459595 V 19:25:40 Temperature Measurement, Probe Number = 0, T = 26.453000 C 19:25:43 Temperature Measurement, Probe Number = 1, T = 28.045000 C 19:25:45 Temperature Measurement, Probe Number = 2, T = 27.910000 C 19:25:47 Temperature Measurement, Probe Number = 3, T = 23.269000 C 19:25:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332697 V 19:25:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332697 (V, A, ohm, ...), Measured Value = 28.509679 (C, atm, Hz, ...) 19:25:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358208 V 19:25:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358208 (V, A, ohm, ...), Measured Value = 28.863996 (C, atm, Hz, ...) 19:25:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267451 V 19:25:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267451 (V, A, ohm, ...), Measured Value = 95.058825 (C, atm, Hz, ...) 19:25:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091398 V 19:25:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091398 (V, A, ohm, ...), Measured Value = 6.854827 (C, atm, Hz, ...) 19:26:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000875 V 19:26:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000875 (V, A, ohm, ...), Measured Value = 0.875310 (C, atm, Hz, ...) 19:26:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.05 P4 = Left Coil Middle, Value = 27.91 P5 = Ambient, Value = 23.27 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.86 P8 = Supply Pres(psi), Value = 95.06 P9 = Return Pres(psi), Value = 6.85 P10 = Flow Rate(gpm), Value = 0.88 19:26:03 Magnet system MAIN current ramping to 0.0000 A... 19:27:28 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:27:30 Main (V) Voltage Measurement, V = 0.000005 V 19:27:35 Temperature Measurement, Probe Number = 0, T = 26.453000 C 19:27:37 Temperature Measurement, Probe Number = 1, T = 28.264000 C 19:27:39 Temperature Measurement, Probe Number = 2, T = 27.999000 C 19:27:41 Temperature Measurement, Probe Number = 3, T = 23.249000 C 19:27:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332851 V 19:27:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332851 (V, A, ohm, ...), Measured Value = 28.511814 (C, atm, Hz, ...) 19:27:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359644 V 19:27:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359644 (V, A, ohm, ...), Measured Value = 28.883946 (C, atm, Hz, ...) 19:27:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278637 V 19:27:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278637 (V, A, ohm, ...), Measured Value = 95.897783 (C, atm, Hz, ...) 19:27:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091621 V 19:27:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091621 (V, A, ohm, ...), Measured Value = 6.871590 (C, atm, Hz, ...) 19:27:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 19:27:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.872921 (C, atm, Hz, ...) 19:27:58 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 28.00 P5 = Ambient, Value = 23.25 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.88 P8 = Supply Pres(psi), Value = 95.90 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.87 19:27:58 Magnet system MAIN current ramping to 125.0000 A... 19:29:22 Magnet Current for MAIN, Imag = 124.9920 A Vtrans = 1.249919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:29:24 Main (V) Voltage Measurement, V = 4.459600 V 19:29:29 Temperature Measurement, Probe Number = 0, T = 26.455000 C 19:29:31 Temperature Measurement, Probe Number = 1, T = 28.062000 C 19:29:33 Temperature Measurement, Probe Number = 2, T = 27.927000 C 19:29:35 Temperature Measurement, Probe Number = 3, T = 23.279000 C 19:29:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332737 V 19:29:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332737 (V, A, ohm, ...), Measured Value = 28.510235 (C, atm, Hz, ...) 19:29:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358201 V 19:29:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358201 (V, A, ohm, ...), Measured Value = 28.863907 (C, atm, Hz, ...) 19:29:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270678 V 19:29:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270678 (V, A, ohm, ...), Measured Value = 95.300827 (C, atm, Hz, ...) 19:29:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091491 V 19:29:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091491 (V, A, ohm, ...), Measured Value = 6.861803 (C, atm, Hz, ...) 19:29:52 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 19:29:52 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895729 (C, atm, Hz, ...) 19:29:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.93 P5 = Ambient, Value = 23.28 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.86 P8 = Supply Pres(psi), Value = 95.30 P9 = Return Pres(psi), Value = 6.86 P10 = Flow Rate(gpm), Value = 0.90 19:29:52 Magnet system MAIN current ramping to 0.0000 A... 19:31:15 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:31:17 Main (V) Voltage Measurement, V = 0.000001 V 19:31:22 Temperature Measurement, Probe Number = 0, T = 26.454000 C 19:31:25 Temperature Measurement, Probe Number = 1, T = 28.262000 C 19:31:27 Temperature Measurement, Probe Number = 2, T = 27.980000 C 19:31:29 Temperature Measurement, Probe Number = 3, T = 23.209000 C 19:31:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332683 V 19:31:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332683 (V, A, ohm, ...), Measured Value = 28.509482 (C, atm, Hz, ...) 19:31:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359851 V 19:31:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359851 (V, A, ohm, ...), Measured Value = 28.886817 (C, atm, Hz, ...) 19:31:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274421 V 19:31:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274421 (V, A, ohm, ...), Measured Value = 95.581575 (C, atm, Hz, ...) 19:31:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091619 V 19:31:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091619 (V, A, ohm, ...), Measured Value = 6.871395 (C, atm, Hz, ...) 19:31:45 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 19:31:45 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900310 (C, atm, Hz, ...) 19:31:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.26 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.21 P6 = Supply Temp(C), Value = 28.51 P7 = Return Temp(C), Value = 28.89 P8 = Supply Pres(psi), Value = 95.58 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.90 19:31:45 Magnet system MAIN current ramping to 75.0000 A... 19:32:41 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:32:43 Main (V) Voltage Measurement, V = 2.670533 V 19:32:48 Temperature Measurement, Probe Number = 0, T = 26.457000 C 19:32:50 Temperature Measurement, Probe Number = 1, T = 28.019000 C 19:32:52 Temperature Measurement, Probe Number = 2, T = 27.780000 C 19:32:54 Temperature Measurement, Probe Number = 3, T = 23.191000 C 19:32:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332298 V 19:32:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332298 (V, A, ohm, ...), Measured Value = 28.504136 (C, atm, Hz, ...) 19:32:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362057 V 19:32:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362057 (V, A, ohm, ...), Measured Value = 28.917458 (C, atm, Hz, ...) 19:33:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274270 V 19:33:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274270 (V, A, ohm, ...), Measured Value = 95.570243 (C, atm, Hz, ...) 19:33:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091595 V 19:33:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091595 (V, A, ohm, ...), Measured Value = 6.869648 (C, atm, Hz, ...) 19:33:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 19:33:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885554 (C, atm, Hz, ...) 19:33:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.46 P3 = Right Coil Outgoing Side, Value = 28.02 P4 = Left Coil Middle, Value = 27.78 P5 = Ambient, Value = 23.19 P6 = Supply Temp(C), Value = 28.50 P7 = Return Temp(C), Value = 28.92 P8 = Supply Pres(psi), Value = 95.57 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.89 19:33:11 Magnetic Field Measurement Measuring the magnet strength... 19:33:11 Integrated Voltage Measurement... 19:33:13 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401047 Vs 19:33:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014404431 Vs 19:33:35 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:33:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400614 Vs 19:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400741 Vs 19:33:56 Magnet Current for MAIN, Imag = 75.0217 A Vtrans = 0.750216 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:34:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399585 Vs 19:34:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402988 Vs 19:34:17 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400755 Vs 19:34:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400551 Vs 19:34:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401339 +- 0.000000847 Vs 19:34:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401339 +- 0.000000847 Vs BL = -0.16001488 +- 0.00000941 Tm 19:34:39 Position moved: 0.000000 m 19:34:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00001 -0.16001 0.00000 19:34:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00001 SL = -0.1600149 +- 0.0000094 Tm^2/m^n 19:34:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600149 +- 0.0000094 Tm^2/m^n 19:34:42 Position moved: 0.000000 m 19:34:42 Magnet system MAIN current ramping to 125.0000 A... 19:35:21 Magnet system MAIN current ramping to 0.0000 A... 19:36:43 Magnet system MAIN current ramping to 125.0000 A... 19:38:05 Magnet system MAIN current ramping to 0.0000 A... 19:39:27 Magnet system MAIN current ramping to 125.0000 A... 19:40:48 Magnet system MAIN current ramping to 0.0000 A... 19:42:13 Position moved: 0.000000 m 19:42:16 Magnet system MAIN current ramping to 87.5000 A... 19:43:18 Magnet Current for MAIN, Imag = 87.4688 A Vtrans = 0.874687 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:43:21 Main (V) Voltage Measurement, V = 3.114937 V 19:43:26 Temperature Measurement, Probe Number = 0, T = 26.428000 C 19:43:28 Temperature Measurement, Probe Number = 1, T = 28.020000 C 19:43:30 Temperature Measurement, Probe Number = 2, T = 27.897000 C 19:43:32 Temperature Measurement, Probe Number = 3, T = 23.177000 C 19:43:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330691 V 19:43:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330691 (V, A, ohm, ...), Measured Value = 28.481818 (C, atm, Hz, ...) 19:43:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.354583 V 19:43:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354583 (V, A, ohm, ...), Measured Value = 28.813657 (C, atm, Hz, ...) 19:43:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265086 V 19:43:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265086 (V, A, ohm, ...), Measured Value = 94.881450 (C, atm, Hz, ...) 19:43:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091502 V 19:43:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091502 (V, A, ohm, ...), Measured Value = 6.862672 (C, atm, Hz, ...) 19:43:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 19:43:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900045 (C, atm, Hz, ...) 19:43:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.43 P3 = Right Coil Outgoing Side, Value = 28.02 P4 = Left Coil Middle, Value = 27.90 P5 = Ambient, Value = 23.18 P6 = Supply Temp(C), Value = 28.48 P7 = Return Temp(C), Value = 28.81 P8 = Supply Pres(psi), Value = 94.88 P9 = Return Pres(psi), Value = 6.86 P10 = Flow Rate(gpm), Value = 0.90 19:43:48 Magnetic Field Measurement Measuring the magnet strength... 19:43:48 Integrated Voltage Measurement... 19:43:51 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:44:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774135 Vs 19:44:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775349 Vs 19:44:12 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773659 Vs 19:44:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774807 Vs 19:44:33 Magnet Current for MAIN, Imag = 87.4692 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780132 Vs 19:44:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776184 Vs 19:44:54 Magnet Current for MAIN, Imag = 87.4689 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:45:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778172 Vs 19:45:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776192 Vs 19:45:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776079 +- 0.000001638 Vs 19:45:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776079 +- 0.000001638 Vs BL = -0.18640087 +- 0.00001820 Tm 19:45:17 Position moved: 0.000000 m 19:45:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18640 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18640 0.00002 -0.18640 0.00000 19:45:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18640 0.00002 SL = -0.1864009 +- 0.0000182 Tm^2/m^n 19:45:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864009 +- 0.0000182 Tm^2/m^n 19:45:19 Position moved: 0.000000 m 19:45:19 Magnet system MAIN current ramping to 75.0000 A... 19:45:40 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:45:42 Main (V) Voltage Measurement, V = 2.673472 V 19:45:47 Temperature Measurement, Probe Number = 0, T = 26.432000 C 19:45:49 Temperature Measurement, Probe Number = 1, T = 28.063000 C 19:45:51 Temperature Measurement, Probe Number = 2, T = 27.943000 C 19:45:53 Temperature Measurement, Probe Number = 3, T = 23.136000 C 19:45:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330102 V 19:45:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330102 (V, A, ohm, ...), Measured Value = 28.473637 (C, atm, Hz, ...) 19:45:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.347550 V 19:45:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347550 (V, A, ohm, ...), Measured Value = 28.715972 (C, atm, Hz, ...) 19:46:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.269412 V 19:46:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.269412 (V, A, ohm, ...), Measured Value = 95.205885 (C, atm, Hz, ...) 19:46:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091400 V 19:46:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091400 (V, A, ohm, ...), Measured Value = 6.855023 (C, atm, Hz, ...) 19:46:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000897 V 19:46:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000897 (V, A, ohm, ...), Measured Value = 0.897110 (C, atm, Hz, ...) 19:46:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.43 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.94 P5 = Ambient, Value = 23.14 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.72 P8 = Supply Pres(psi), Value = 95.21 P9 = Return Pres(psi), Value = 6.86 P10 = Flow Rate(gpm), Value = 0.90 19:46:10 Magnet system MAIN current ramping to 125.0000 A... 19:46:51 Magnet Current for MAIN, Imag = 124.9922 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:46:53 Main (V) Voltage Measurement, V = 4.458510 V 19:46:58 Temperature Measurement, Probe Number = 0, T = 26.425000 C 19:47:00 Temperature Measurement, Probe Number = 1, T = 28.105000 C 19:47:03 Temperature Measurement, Probe Number = 2, T = 27.980000 C 19:47:05 Temperature Measurement, Probe Number = 3, T = 23.171000 C 19:47:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330241 V 19:47:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330241 (V, A, ohm, ...), Measured Value = 28.475575 (C, atm, Hz, ...) 19:47:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.349568 V 19:47:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349568 (V, A, ohm, ...), Measured Value = 28.743994 (C, atm, Hz, ...) 19:47:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270532 V 19:47:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270532 (V, A, ohm, ...), Measured Value = 95.289877 (C, atm, Hz, ...) 19:47:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091679 V 19:47:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091679 (V, A, ohm, ...), Measured Value = 6.875948 (C, atm, Hz, ...) 19:47:21 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 19:47:21 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885564 (C, atm, Hz, ...) 19:47:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.43 P3 = Right Coil Outgoing Side, Value = 28.11 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.17 P6 = Supply Temp(C), Value = 28.48 P7 = Return Temp(C), Value = 28.74 P8 = Supply Pres(psi), Value = 95.29 P9 = Return Pres(psi), Value = 6.88 P10 = Flow Rate(gpm), Value = 0.89 19:47:21 Magnet system MAIN current ramping to 0.0000 A... 19:48:45 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:48:47 Main (V) Voltage Measurement, V = 0.000000 V 19:48:52 Temperature Measurement, Probe Number = 0, T = 26.407000 C 19:48:54 Temperature Measurement, Probe Number = 1, T = 28.219000 C 19:48:56 Temperature Measurement, Probe Number = 2, T = 27.996000 C 19:48:58 Temperature Measurement, Probe Number = 3, T = 23.175000 C 19:49:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330385 V 19:49:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330385 (V, A, ohm, ...), Measured Value = 28.477567 (C, atm, Hz, ...) 19:49:03 Sensor Voltage Measurement, Sensor Number = 1, V = 2.359224 V 19:49:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.359224 (V, A, ohm, ...), Measured Value = 28.878115 (C, atm, Hz, ...) 19:49:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268448 V 19:49:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268448 (V, A, ohm, ...), Measured Value = 95.133615 (C, atm, Hz, ...) 19:49:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091533 V 19:49:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091533 (V, A, ohm, ...), Measured Value = 6.864998 (C, atm, Hz, ...) 19:49:15 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000868 V 19:49:15 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000868 (V, A, ohm, ...), Measured Value = 0.868039 (C, atm, Hz, ...) 19:49:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.41 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 28.00 P5 = Ambient, Value = 23.18 P6 = Supply Temp(C), Value = 28.48 P7 = Return Temp(C), Value = 28.88 P8 = Supply Pres(psi), Value = 95.13 P9 = Return Pres(psi), Value = 6.86 P10 = Flow Rate(gpm), Value = 0.87 19:49:15 Magnet system MAIN current ramping to 125.0000 A... 19:50:39 Magnet Current for MAIN, Imag = 124.9938 A Vtrans = 1.249937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:50:41 Main (V) Voltage Measurement, V = 4.459167 V 19:50:46 Temperature Measurement, Probe Number = 0, T = 26.428000 C 19:50:48 Temperature Measurement, Probe Number = 1, T = 27.990000 C 19:50:50 Temperature Measurement, Probe Number = 2, T = 27.895000 C 19:50:52 Temperature Measurement, Probe Number = 3, T = 23.190000 C 19:50:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329661 V 19:50:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329661 (V, A, ohm, ...), Measured Value = 28.467519 (C, atm, Hz, ...) 19:50:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.356349 V 19:50:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356349 (V, A, ohm, ...), Measured Value = 28.838181 (C, atm, Hz, ...) 19:50:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267007 V 19:50:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267007 (V, A, ohm, ...), Measured Value = 95.025503 (C, atm, Hz, ...) 19:51:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091843 V 19:51:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091843 (V, A, ohm, ...), Measured Value = 6.888248 (C, atm, Hz, ...) 19:51:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000906 V 19:51:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000906 (V, A, ohm, ...), Measured Value = 0.905703 (C, atm, Hz, ...) 19:51:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.43 P3 = Right Coil Outgoing Side, Value = 27.99 P4 = Left Coil Middle, Value = 27.89 P5 = Ambient, Value = 23.19 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.84 P8 = Supply Pres(psi), Value = 95.03 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.91 19:51:09 Magnet system MAIN current ramping to 0.0000 A... 19:52:32 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:52:35 Main (V) Voltage Measurement, V = 0.000000 V 19:52:40 Temperature Measurement, Probe Number = 0, T = 26.414000 C 19:52:42 Temperature Measurement, Probe Number = 1, T = 28.171000 C 19:52:44 Temperature Measurement, Probe Number = 2, T = 27.948000 C 19:52:46 Temperature Measurement, Probe Number = 3, T = 23.125000 C 19:52:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329864 V 19:52:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329864 (V, A, ohm, ...), Measured Value = 28.470336 (C, atm, Hz, ...) 19:52:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.357545 V 19:52:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.357545 (V, A, ohm, ...), Measured Value = 28.854793 (C, atm, Hz, ...) 19:52:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268443 V 19:52:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268443 (V, A, ohm, ...), Measured Value = 95.133232 (C, atm, Hz, ...) 19:52:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091766 V 19:52:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091766 (V, A, ohm, ...), Measured Value = 6.882435 (C, atm, Hz, ...) 19:53:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 19:53:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878290 (C, atm, Hz, ...) 19:53:02 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.41 P3 = Right Coil Outgoing Side, Value = 28.17 P4 = Left Coil Middle, Value = 27.95 P5 = Ambient, Value = 23.12 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.85 P8 = Supply Pres(psi), Value = 95.13 P9 = Return Pres(psi), Value = 6.88 P10 = Flow Rate(gpm), Value = 0.88 19:53:02 Magnet system MAIN current ramping to 125.0000 A... 19:54:27 Magnet Current for MAIN, Imag = 124.9921 A Vtrans = 1.249920 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:54:29 Main (V) Voltage Measurement, V = 4.459056 V 19:54:34 Temperature Measurement, Probe Number = 0, T = 26.408000 C 19:54:36 Temperature Measurement, Probe Number = 1, T = 27.988000 C 19:54:38 Temperature Measurement, Probe Number = 2, T = 27.863000 C 19:54:40 Temperature Measurement, Probe Number = 3, T = 23.139000 C 19:54:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329286 V 19:54:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329286 (V, A, ohm, ...), Measured Value = 28.462299 (C, atm, Hz, ...) 19:54:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.356084 V 19:54:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356084 (V, A, ohm, ...), Measured Value = 28.834503 (C, atm, Hz, ...) 19:54:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281293 V 19:54:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281293 (V, A, ohm, ...), Measured Value = 96.096960 (C, atm, Hz, ...) 19:54:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091860 V 19:54:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091860 (V, A, ohm, ...), Measured Value = 6.889507 (C, atm, Hz, ...) 19:54:57 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000901 V 19:54:57 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000901 (V, A, ohm, ...), Measured Value = 0.900704 (C, atm, Hz, ...) 19:54:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.41 P3 = Right Coil Outgoing Side, Value = 27.99 P4 = Left Coil Middle, Value = 27.86 P5 = Ambient, Value = 23.14 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 96.10 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.90 19:54:57 Magnet system MAIN current ramping to 0.0000 A... 19:56:21 Magnet Current for MAIN, Imag = 0.0005 A Vtrans = 0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:56:23 Main (V) Voltage Measurement, V = 0.000003 V 19:56:28 Temperature Measurement, Probe Number = 0, T = 26.397000 C 19:56:30 Temperature Measurement, Probe Number = 1, T = 28.186000 C 19:56:32 Temperature Measurement, Probe Number = 2, T = 27.944000 C 19:56:35 Temperature Measurement, Probe Number = 3, T = 23.104000 C 19:56:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329846 V 19:56:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329846 (V, A, ohm, ...), Measured Value = 28.470085 (C, atm, Hz, ...) 19:56:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.357701 V 19:56:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.357701 (V, A, ohm, ...), Measured Value = 28.856964 (C, atm, Hz, ...) 19:56:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275094 V 19:56:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275094 (V, A, ohm, ...), Measured Value = 95.632050 (C, atm, Hz, ...) 19:56:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091714 V 19:56:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091714 (V, A, ohm, ...), Measured Value = 6.878565 (C, atm, Hz, ...) 19:56:51 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 19:56:51 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.904881 (C, atm, Hz, ...) 19:56:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.40 P3 = Right Coil Outgoing Side, Value = 28.19 P4 = Left Coil Middle, Value = 27.94 P5 = Ambient, Value = 23.10 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.86 P8 = Supply Pres(psi), Value = 95.63 P9 = Return Pres(psi), Value = 6.88 P10 = Flow Rate(gpm), Value = 0.90 19:56:51 Magnet system MAIN current ramping to 125.0000 A... 19:58:15 Magnet Current for MAIN, Imag = 124.9924 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 19:58:17 Main (V) Voltage Measurement, V = 4.459007 V 19:58:22 Temperature Measurement, Probe Number = 0, T = 26.383000 C 19:58:24 Temperature Measurement, Probe Number = 1, T = 27.998000 C 19:58:27 Temperature Measurement, Probe Number = 2, T = 27.895000 C 19:58:29 Temperature Measurement, Probe Number = 3, T = 23.101000 C 19:58:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329837 V 19:58:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329837 (V, A, ohm, ...), Measured Value = 28.469960 (C, atm, Hz, ...) 19:58:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355794 V 19:58:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355794 (V, A, ohm, ...), Measured Value = 28.830467 (C, atm, Hz, ...) 19:58:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272056 V 19:58:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272056 (V, A, ohm, ...), Measured Value = 95.404192 (C, atm, Hz, ...) 19:58:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091908 V 19:58:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091908 (V, A, ohm, ...), Measured Value = 6.893093 (C, atm, Hz, ...) 19:58:45 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 19:58:45 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880375 (C, atm, Hz, ...) 19:58:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.38 P3 = Right Coil Outgoing Side, Value = 28.00 P4 = Left Coil Middle, Value = 27.89 P5 = Ambient, Value = 23.10 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 95.40 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.88 19:58:45 Magnet system MAIN current ramping to 0.0000 A... 20:00:09 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:00:11 Main (V) Voltage Measurement, V = 0.000000 V 20:00:16 Temperature Measurement, Probe Number = 0, T = 26.392000 C 20:00:18 Temperature Measurement, Probe Number = 1, T = 28.220000 C 20:00:20 Temperature Measurement, Probe Number = 2, T = 27.978000 C 20:00:23 Temperature Measurement, Probe Number = 3, T = 23.049000 C 20:00:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330128 V 20:00:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330128 (V, A, ohm, ...), Measured Value = 28.473996 (C, atm, Hz, ...) 20:00:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.357055 V 20:00:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.357055 (V, A, ohm, ...), Measured Value = 28.847993 (C, atm, Hz, ...) 20:00:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266001 V 20:00:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266001 (V, A, ohm, ...), Measured Value = 94.950038 (C, atm, Hz, ...) 20:00:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091899 V 20:00:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091899 (V, A, ohm, ...), Measured Value = 6.892417 (C, atm, Hz, ...) 20:00:39 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 20:00:39 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896233 (C, atm, Hz, ...) 20:00:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.39 P3 = Right Coil Outgoing Side, Value = 28.22 P4 = Left Coil Middle, Value = 27.98 P5 = Ambient, Value = 23.05 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.85 P8 = Supply Pres(psi), Value = 94.95 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.90 20:00:39 Magnet system MAIN current ramping to 75.0000 A... 20:01:35 Magnet Current for MAIN, Imag = 75.0221 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:01:37 Main (V) Voltage Measurement, V = 2.670243 V 20:01:42 Temperature Measurement, Probe Number = 0, T = 26.382000 C 20:01:44 Temperature Measurement, Probe Number = 1, T = 27.979000 C 20:01:46 Temperature Measurement, Probe Number = 2, T = 27.736000 C 20:01:48 Temperature Measurement, Probe Number = 3, T = 23.026000 C 20:01:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330176 V 20:01:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330176 (V, A, ohm, ...), Measured Value = 28.474660 (C, atm, Hz, ...) 20:01:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358930 V 20:01:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358930 (V, A, ohm, ...), Measured Value = 28.874025 (C, atm, Hz, ...) 20:01:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268459 V 20:01:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268459 (V, A, ohm, ...), Measured Value = 95.134395 (C, atm, Hz, ...) 20:01:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091935 V 20:01:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091935 (V, A, ohm, ...), Measured Value = 6.895125 (C, atm, Hz, ...) 20:02:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 20:02:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.882862 (C, atm, Hz, ...) 20:02:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.38 P3 = Right Coil Outgoing Side, Value = 27.98 P4 = Left Coil Middle, Value = 27.74 P5 = Ambient, Value = 23.03 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.87 P8 = Supply Pres(psi), Value = 95.13 P9 = Return Pres(psi), Value = 6.90 P10 = Flow Rate(gpm), Value = 0.88 20:02:05 Magnetic Field Measurement Measuring the magnet strength... 20:02:05 Integrated Voltage Measurement... 20:02:07 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:02:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397282 Vs 20:02:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405425 Vs 20:02:29 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:02:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014398109 Vs 20:02:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405741 Vs 20:02:50 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:02:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404096 Vs 20:03:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405029 Vs 20:03:10 Magnet Current for MAIN, Imag = 75.0215 A Vtrans = 0.750215 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:03:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403269 Vs 20:03:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405955 Vs 20:03:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403113 +- 0.000001488 Vs 20:03:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403113 +- 0.000001488 Vs BL = -0.16003459 +- 0.00001653 Tm 20:03:33 Position moved: 0.000000 m 20:03:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16003 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16003 0.00002 -0.16003 0.00000 20:03:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16003 0.00002 SL = -0.1600346 +- 0.0000165 Tm^2/m^n 20:03:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600346 +- 0.0000165 Tm^2/m^n 20:03:36 Position moved: 0.000000 m 20:03:36 Magnet system MAIN current ramping to 125.0000 A... 20:04:15 Magnet system MAIN current ramping to 0.0000 A... 20:05:37 Magnet system MAIN current ramping to 125.0000 A... 20:06:59 Magnet system MAIN current ramping to 0.0000 A... 20:08:21 Magnet system MAIN current ramping to 125.0000 A... 20:09:44 Magnet system MAIN current ramping to 0.0000 A... 20:11:08 Position moved: 0.000000 m 20:11:11 Magnet system MAIN current ramping to 87.5000 A... 20:12:14 Magnet Current for MAIN, Imag = 87.4685 A Vtrans = 0.874684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:12:16 Main (V) Voltage Measurement, V = 3.114572 V 20:12:21 Temperature Measurement, Probe Number = 0, T = 26.368000 C 20:12:23 Temperature Measurement, Probe Number = 1, T = 27.964000 C 20:12:25 Temperature Measurement, Probe Number = 2, T = 27.730000 C 20:12:27 Temperature Measurement, Probe Number = 3, T = 22.980000 C 20:12:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329336 V 20:12:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329336 (V, A, ohm, ...), Measured Value = 28.462999 (C, atm, Hz, ...) 20:12:31 Sensor Voltage Measurement, Sensor Number = 1, V = 2.351447 V 20:12:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351447 (V, A, ohm, ...), Measured Value = 28.770097 (C, atm, Hz, ...) 20:12:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.277233 V 20:12:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.277233 (V, A, ohm, ...), Measured Value = 95.792475 (C, atm, Hz, ...) 20:12:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091830 V 20:12:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091830 (V, A, ohm, ...), Measured Value = 6.887280 (C, atm, Hz, ...) 20:12:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 20:12:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895841 (C, atm, Hz, ...) 20:12:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.37 P3 = Right Coil Outgoing Side, Value = 27.96 P4 = Left Coil Middle, Value = 27.73 P5 = Ambient, Value = 22.98 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.77 P8 = Supply Pres(psi), Value = 95.79 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.90 20:12:44 Magnetic Field Measurement Measuring the magnet strength... 20:12:44 Integrated Voltage Measurement... 20:12:46 Magnet Current for MAIN, Imag = 87.4684 A Vtrans = 0.874683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:12:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016771384 Vs 20:13:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779240 Vs 20:13:07 Magnet Current for MAIN, Imag = 87.4684 A Vtrans = 0.874683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:13:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772610 Vs 20:13:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776186 Vs 20:13:28 Magnet Current for MAIN, Imag = 87.4681 A Vtrans = 0.874680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:13:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775375 Vs 20:13:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016781363 Vs 20:13:49 Magnet Current for MAIN, Imag = 87.4684 A Vtrans = 0.874683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:13:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775139 Vs 20:14:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016781333 Vs 20:14:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776579 +- 0.000001754 Vs 20:14:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776579 +- 0.000001754 Vs BL = -0.18640643 +- 0.00001949 Tm 20:14:12 Position moved: 0.000000 m 20:14:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00002 -0.18641 0.00000 20:14:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00002 SL = -0.1864064 +- 0.0000195 Tm^2/m^n 20:14:12 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864064 +- 0.0000195 Tm^2/m^n 20:14:15 Position moved: 0.000000 m 20:14:15 Magnet system MAIN current ramping to 75.0000 A... 20:14:35 Magnet Current for MAIN, Imag = 75.0219 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:14:37 Main (V) Voltage Measurement, V = 2.673191 V 20:14:42 Temperature Measurement, Probe Number = 0, T = 26.349000 C 20:14:44 Temperature Measurement, Probe Number = 1, T = 28.014000 C 20:14:46 Temperature Measurement, Probe Number = 2, T = 27.843000 C 20:14:48 Temperature Measurement, Probe Number = 3, T = 22.907000 C 20:14:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329320 V 20:14:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329320 (V, A, ohm, ...), Measured Value = 28.462783 (C, atm, Hz, ...) 20:14:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.344521 V 20:14:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344521 (V, A, ohm, ...), Measured Value = 28.673903 (C, atm, Hz, ...) 20:14:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265386 V 20:14:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265386 (V, A, ohm, ...), Measured Value = 94.903920 (C, atm, Hz, ...) 20:14:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091850 V 20:14:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091850 (V, A, ohm, ...), Measured Value = 6.888735 (C, atm, Hz, ...) 20:15:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 20:15:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890295 (C, atm, Hz, ...) 20:15:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.35 P3 = Right Coil Outgoing Side, Value = 28.01 P4 = Left Coil Middle, Value = 27.84 P5 = Ambient, Value = 22.91 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.67 P8 = Supply Pres(psi), Value = 94.90 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.89 20:15:05 Magnet system MAIN current ramping to 125.0000 A... 20:15:46 Magnet Current for MAIN, Imag = 124.9925 A Vtrans = 1.249924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:15:49 Main (V) Voltage Measurement, V = 4.458107 V 20:15:54 Temperature Measurement, Probe Number = 0, T = 26.349000 C 20:15:56 Temperature Measurement, Probe Number = 1, T = 28.065000 C 20:15:58 Temperature Measurement, Probe Number = 2, T = 27.878000 C 20:16:00 Temperature Measurement, Probe Number = 3, T = 22.912000 C 20:16:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329514 V 20:16:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329514 (V, A, ohm, ...), Measured Value = 28.465475 (C, atm, Hz, ...) 20:16:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.346617 V 20:16:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346617 (V, A, ohm, ...), Measured Value = 28.703019 (C, atm, Hz, ...) 20:16:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259250 V 20:16:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259250 (V, A, ohm, ...), Measured Value = 94.443758 (C, atm, Hz, ...) 20:16:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091878 V 20:16:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091878 (V, A, ohm, ...), Measured Value = 6.890865 (C, atm, Hz, ...) 20:16:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 20:16:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897720 (C, atm, Hz, ...) 20:16:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.35 P3 = Right Coil Outgoing Side, Value = 28.07 P4 = Left Coil Middle, Value = 27.88 P5 = Ambient, Value = 22.91 P6 = Supply Temp(C), Value = 28.47 P7 = Return Temp(C), Value = 28.70 P8 = Supply Pres(psi), Value = 94.44 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.90 20:16:16 Magnet system MAIN current ramping to 0.0000 A... 20:17:40 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:17:43 Main (V) Voltage Measurement, V = 0.000000 V 20:17:48 Temperature Measurement, Probe Number = 0, T = 26.351000 C 20:17:50 Temperature Measurement, Probe Number = 1, T = 28.203000 C 20:17:52 Temperature Measurement, Probe Number = 2, T = 27.882000 C 20:17:54 Temperature Measurement, Probe Number = 3, T = 22.889000 C 20:17:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328919 V 20:17:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328919 (V, A, ohm, ...), Measured Value = 28.457204 (C, atm, Hz, ...) 20:17:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.356009 V 20:17:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356009 (V, A, ohm, ...), Measured Value = 28.833462 (C, atm, Hz, ...) 20:18:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265470 V 20:18:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265470 (V, A, ohm, ...), Measured Value = 94.910220 (C, atm, Hz, ...) 20:18:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092073 V 20:18:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092073 (V, A, ohm, ...), Measured Value = 6.905490 (C, atm, Hz, ...) 20:18:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 20:18:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880183 (C, atm, Hz, ...) 20:18:10 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.35 P3 = Right Coil Outgoing Side, Value = 28.20 P4 = Left Coil Middle, Value = 27.88 P5 = Ambient, Value = 22.89 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 94.91 P9 = Return Pres(psi), Value = 6.91 P10 = Flow Rate(gpm), Value = 0.88 20:18:10 Magnet system MAIN current ramping to 125.0000 A... 20:19:34 Magnet Current for MAIN, Imag = 124.9919 A Vtrans = 1.249918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:19:36 Main (V) Voltage Measurement, V = 4.458603 V 20:19:42 Temperature Measurement, Probe Number = 0, T = 26.341000 C 20:19:44 Temperature Measurement, Probe Number = 1, T = 27.974000 C 20:19:46 Temperature Measurement, Probe Number = 2, T = 27.780000 C 20:19:48 Temperature Measurement, Probe Number = 3, T = 22.930000 C 20:19:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328902 V 20:19:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328902 (V, A, ohm, ...), Measured Value = 28.456971 (C, atm, Hz, ...) 20:19:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353210 V 20:19:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353210 (V, A, ohm, ...), Measured Value = 28.794586 (C, atm, Hz, ...) 20:19:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272979 V 20:19:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272979 (V, A, ohm, ...), Measured Value = 95.473462 (C, atm, Hz, ...) 20:19:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092055 V 20:19:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092055 (V, A, ohm, ...), Measured Value = 6.904140 (C, atm, Hz, ...) 20:20:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 20:20:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897667 (C, atm, Hz, ...) 20:20:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.34 P3 = Right Coil Outgoing Side, Value = 27.97 P4 = Left Coil Middle, Value = 27.78 P5 = Ambient, Value = 22.93 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.47 P9 = Return Pres(psi), Value = 6.90 P10 = Flow Rate(gpm), Value = 0.90 20:20:04 Magnet system MAIN current ramping to 0.0000 A... 20:21:28 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:21:30 Main (V) Voltage Measurement, V = -0.000001 V 20:21:36 Temperature Measurement, Probe Number = 0, T = 26.336000 C 20:21:38 Temperature Measurement, Probe Number = 1, T = 28.169000 C 20:21:40 Temperature Measurement, Probe Number = 2, T = 27.897000 C 20:21:42 Temperature Measurement, Probe Number = 3, T = 22.890000 C 20:21:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329105 V 20:21:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329105 (V, A, ohm, ...), Measured Value = 28.459787 (C, atm, Hz, ...) 20:21:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.354637 V 20:21:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354637 (V, A, ohm, ...), Measured Value = 28.814410 (C, atm, Hz, ...) 20:21:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270984 V 20:21:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270984 (V, A, ohm, ...), Measured Value = 95.323785 (C, atm, Hz, ...) 20:21:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091911 V 20:21:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091911 (V, A, ohm, ...), Measured Value = 6.893288 (C, atm, Hz, ...) 20:21:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 20:21:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885706 (C, atm, Hz, ...) 20:21:58 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.34 P3 = Right Coil Outgoing Side, Value = 28.17 P4 = Left Coil Middle, Value = 27.90 P5 = Ambient, Value = 22.89 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.81 P8 = Supply Pres(psi), Value = 95.32 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.89 20:21:58 Magnet system MAIN current ramping to 125.0000 A... 20:23:22 Magnet Current for MAIN, Imag = 124.9915 A Vtrans = 1.249914 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:23:24 Main (V) Voltage Measurement, V = 4.458603 V 20:23:30 Temperature Measurement, Probe Number = 0, T = 26.320000 C 20:23:32 Temperature Measurement, Probe Number = 1, T = 27.957000 C 20:23:34 Temperature Measurement, Probe Number = 2, T = 27.785000 C 20:23:36 Temperature Measurement, Probe Number = 3, T = 22.906000 C 20:23:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328542 V 20:23:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328542 (V, A, ohm, ...), Measured Value = 28.451965 (C, atm, Hz, ...) 20:23:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352978 V 20:23:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352978 (V, A, ohm, ...), Measured Value = 28.791357 (C, atm, Hz, ...) 20:23:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272787 V 20:23:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272787 (V, A, ohm, ...), Measured Value = 95.459025 (C, atm, Hz, ...) 20:23:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091899 V 20:23:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091899 (V, A, ohm, ...), Measured Value = 6.892417 (C, atm, Hz, ...) 20:23:52 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 20:23:52 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880523 (C, atm, Hz, ...) 20:23:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.32 P3 = Right Coil Outgoing Side, Value = 27.96 P4 = Left Coil Middle, Value = 27.79 P5 = Ambient, Value = 22.91 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.46 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.88 20:23:52 Magnet system MAIN current ramping to 0.0000 A... 20:25:16 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:25:19 Main (V) Voltage Measurement, V = 0.000004 V 20:25:24 Temperature Measurement, Probe Number = 0, T = 26.319000 C 20:25:26 Temperature Measurement, Probe Number = 1, T = 28.169000 C 20:25:28 Temperature Measurement, Probe Number = 2, T = 27.901000 C 20:25:30 Temperature Measurement, Probe Number = 3, T = 22.906000 C 20:25:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328436 V 20:25:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328436 (V, A, ohm, ...), Measured Value = 28.450494 (C, atm, Hz, ...) 20:25:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.354386 V 20:25:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354386 (V, A, ohm, ...), Measured Value = 28.810911 (C, atm, Hz, ...) 20:25:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264126 V 20:25:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264126 (V, A, ohm, ...), Measured Value = 94.809465 (C, atm, Hz, ...) 20:25:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091666 V 20:25:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091666 (V, A, ohm, ...), Measured Value = 6.874980 (C, atm, Hz, ...) 20:25:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 20:25:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885432 (C, atm, Hz, ...) 20:25:46 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.32 P3 = Right Coil Outgoing Side, Value = 28.17 P4 = Left Coil Middle, Value = 27.90 P5 = Ambient, Value = 22.91 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.81 P8 = Supply Pres(psi), Value = 94.81 P9 = Return Pres(psi), Value = 6.87 P10 = Flow Rate(gpm), Value = 0.89 20:25:46 Magnet system MAIN current ramping to 125.0000 A... 20:27:11 Magnet Current for MAIN, Imag = 124.9929 A Vtrans = 1.249928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:27:13 Main (V) Voltage Measurement, V = 4.458533 V 20:27:18 Temperature Measurement, Probe Number = 0, T = 26.316000 C 20:27:20 Temperature Measurement, Probe Number = 1, T = 27.943000 C 20:27:22 Temperature Measurement, Probe Number = 2, T = 27.838000 C 20:27:24 Temperature Measurement, Probe Number = 3, T = 22.906000 C 20:27:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328799 V 20:27:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328799 (V, A, ohm, ...), Measured Value = 28.455536 (C, atm, Hz, ...) 20:27:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352600 V 20:27:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352600 (V, A, ohm, ...), Measured Value = 28.786118 (C, atm, Hz, ...) 20:27:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267242 V 20:27:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267242 (V, A, ohm, ...), Measured Value = 95.043135 (C, atm, Hz, ...) 20:27:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091994 V 20:27:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091994 (V, A, ohm, ...), Measured Value = 6.899587 (C, atm, Hz, ...) 20:27:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000892 V 20:27:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000892 (V, A, ohm, ...), Measured Value = 0.891900 (C, atm, Hz, ...) 20:27:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.32 P3 = Right Coil Outgoing Side, Value = 27.94 P4 = Left Coil Middle, Value = 27.84 P5 = Ambient, Value = 22.91 P6 = Supply Temp(C), Value = 28.46 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.04 P9 = Return Pres(psi), Value = 6.90 P10 = Flow Rate(gpm), Value = 0.89 20:27:41 Magnet system MAIN current ramping to 0.0000 A... 20:29:05 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:29:07 Main (V) Voltage Measurement, V = 0.000003 V 20:29:12 Temperature Measurement, Probe Number = 0, T = 26.314000 C 20:29:14 Temperature Measurement, Probe Number = 1, T = 28.141000 C 20:29:16 Temperature Measurement, Probe Number = 2, T = 27.942000 C 20:29:19 Temperature Measurement, Probe Number = 3, T = 22.809000 C 20:29:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328447 V 20:29:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328447 (V, A, ohm, ...), Measured Value = 28.450656 (C, atm, Hz, ...) 20:29:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353728 V 20:29:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353728 (V, A, ohm, ...), Measured Value = 28.801781 (C, atm, Hz, ...) 20:29:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272282 V 20:29:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272282 (V, A, ohm, ...), Measured Value = 95.421150 (C, atm, Hz, ...) 20:29:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092050 V 20:29:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092050 (V, A, ohm, ...), Measured Value = 6.903750 (C, atm, Hz, ...) 20:29:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000870 V 20:29:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000870 (V, A, ohm, ...), Measured Value = 0.870229 (C, atm, Hz, ...) 20:29:35 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.31 P3 = Right Coil Outgoing Side, Value = 28.14 P4 = Left Coil Middle, Value = 27.94 P5 = Ambient, Value = 22.81 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.80 P8 = Supply Pres(psi), Value = 95.42 P9 = Return Pres(psi), Value = 6.90 P10 = Flow Rate(gpm), Value = 0.87 20:29:35 Magnet system MAIN current ramping to 75.0000 A... 20:30:30 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:30:32 Main (V) Voltage Measurement, V = 2.669991 V 20:30:37 Temperature Measurement, Probe Number = 0, T = 26.310000 C 20:30:40 Temperature Measurement, Probe Number = 1, T = 27.898000 C 20:30:42 Temperature Measurement, Probe Number = 2, T = 27.706000 C 20:30:44 Temperature Measurement, Probe Number = 3, T = 22.806000 C 20:30:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328437 V 20:30:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328437 (V, A, ohm, ...), Measured Value = 28.450512 (C, atm, Hz, ...) 20:30:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355609 V 20:30:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355609 (V, A, ohm, ...), Measured Value = 28.827901 (C, atm, Hz, ...) 20:30:50 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266188 V 20:30:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266188 (V, A, ohm, ...), Measured Value = 94.964085 (C, atm, Hz, ...) 20:30:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.091930 V 20:30:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.091930 (V, A, ohm, ...), Measured Value = 6.894743 (C, atm, Hz, ...) 20:31:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 20:31:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880768 (C, atm, Hz, ...) 20:31:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.31 P3 = Right Coil Outgoing Side, Value = 27.90 P4 = Left Coil Middle, Value = 27.71 P5 = Ambient, Value = 22.81 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.83 P8 = Supply Pres(psi), Value = 94.96 P9 = Return Pres(psi), Value = 6.89 P10 = Flow Rate(gpm), Value = 0.88 20:31:00 Magnetic Field Measurement Measuring the magnet strength... 20:31:00 Integrated Voltage Measurement... 20:31:02 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:31:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399597 Vs 20:31:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014406098 Vs 20:31:24 Magnet Current for MAIN, Imag = 75.0213 A Vtrans = 0.750212 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401179 Vs 20:31:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014406246 Vs 20:31:45 Magnet Current for MAIN, Imag = 75.0213 A Vtrans = 0.750212 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:31:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401389 Vs 20:32:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014408155 Vs 20:32:06 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:32:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399295 Vs 20:32:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014406595 Vs 20:32:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403569 +- 0.000000771 Vs 20:32:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403569 +- 0.000000771 Vs BL = -0.16003966 +- 0.00000857 Tm 20:32:28 Position moved: 0.000000 m 20:32:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 20:32:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600397 +- 0.0000086 Tm^2/m^n 20:32:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600397 +- 0.0000086 Tm^2/m^n 20:32:31 Position moved: 0.000000 m 20:32:31 Magnet system MAIN current ramping to 125.0000 A... 20:33:10 Magnet system MAIN current ramping to 0.0000 A... 20:34:31 Magnet system MAIN current ramping to 125.0000 A... 20:35:53 Magnet system MAIN current ramping to 0.0000 A... 20:37:16 Magnet system MAIN current ramping to 125.0000 A... 20:38:38 Magnet system MAIN current ramping to 0.0000 A... 20:40:02 Position moved: 0.000000 m 20:40:05 Magnet system MAIN current ramping to 87.5000 A... 20:41:08 Magnet Current for MAIN, Imag = 87.4679 A Vtrans = 0.874678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:41:10 Main (V) Voltage Measurement, V = 3.114371 V 20:41:15 Temperature Measurement, Probe Number = 0, T = 26.301000 C 20:41:17 Temperature Measurement, Probe Number = 1, T = 27.899000 C 20:41:19 Temperature Measurement, Probe Number = 2, T = 27.688000 C 20:41:21 Temperature Measurement, Probe Number = 3, T = 22.735000 C 20:41:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328645 V 20:41:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328645 (V, A, ohm, ...), Measured Value = 28.453401 (C, atm, Hz, ...) 20:41:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.348029 V 20:41:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348029 (V, A, ohm, ...), Measured Value = 28.722628 (C, atm, Hz, ...) 20:41:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267809 V 20:41:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267809 (V, A, ohm, ...), Measured Value = 95.085660 (C, atm, Hz, ...) 20:41:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092035 V 20:41:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092035 (V, A, ohm, ...), Measured Value = 6.902588 (C, atm, Hz, ...) 20:41:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 20:41:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892724 (C, atm, Hz, ...) 20:41:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.30 P3 = Right Coil Outgoing Side, Value = 27.90 P4 = Left Coil Middle, Value = 27.69 P5 = Ambient, Value = 22.73 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.72 P8 = Supply Pres(psi), Value = 95.09 P9 = Return Pres(psi), Value = 6.90 P10 = Flow Rate(gpm), Value = 0.89 20:41:38 Magnetic Field Measurement Measuring the magnet strength... 20:41:38 Integrated Voltage Measurement... 20:41:40 Magnet Current for MAIN, Imag = 87.4680 A Vtrans = 0.874679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:41:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776322 Vs 20:41:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779026 Vs 20:42:02 Magnet Current for MAIN, Imag = 87.4678 A Vtrans = 0.874677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:42:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774631 Vs 20:42:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016778931 Vs 20:42:22 Magnet Current for MAIN, Imag = 87.4680 A Vtrans = 0.874679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:42:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776274 Vs 20:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779389 Vs 20:42:43 Magnet Current for MAIN, Imag = 87.4681 A Vtrans = 0.874680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:42:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774084 Vs 20:43:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777679 Vs 20:43:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777042 +- 0.000000781 Vs 20:43:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016777042 +- 0.000000781 Vs BL = -0.18641158 +- 0.00000868 Tm 20:43:06 Position moved: 0.000000 m 20:43:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00001 -0.18641 0.00000 20:43:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00001 SL = -0.1864116 +- 0.0000087 Tm^2/m^n 20:43:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864116 +- 0.0000087 Tm^2/m^n 20:43:08 Position moved: 0.000000 m 20:43:08 Magnet system MAIN current ramping to 75.0000 A... 20:43:29 Magnet Current for MAIN, Imag = 75.0218 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:43:31 Main (V) Voltage Measurement, V = 2.673043 V 20:43:36 Temperature Measurement, Probe Number = 0, T = 26.297000 C 20:43:38 Temperature Measurement, Probe Number = 1, T = 27.933000 C 20:43:40 Temperature Measurement, Probe Number = 2, T = 27.809000 C 20:43:42 Temperature Measurement, Probe Number = 3, T = 22.702000 C 20:43:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328159 V 20:43:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328159 (V, A, ohm, ...), Measured Value = 28.446656 (C, atm, Hz, ...) 20:43:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340924 V 20:43:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340924 (V, A, ohm, ...), Measured Value = 28.623940 (C, atm, Hz, ...) 20:43:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268611 V 20:43:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268611 (V, A, ohm, ...), Measured Value = 95.145825 (C, atm, Hz, ...) 20:43:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092245 V 20:43:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092245 (V, A, ohm, ...), Measured Value = 6.918375 (C, atm, Hz, ...) 20:43:59 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 20:43:59 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887719 (C, atm, Hz, ...) 20:43:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.30 P3 = Right Coil Outgoing Side, Value = 27.93 P4 = Left Coil Middle, Value = 27.81 P5 = Ambient, Value = 22.70 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.62 P8 = Supply Pres(psi), Value = 95.15 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.89 20:43:59 Magnet system MAIN current ramping to 125.0000 A... 20:44:41 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:44:43 Main (V) Voltage Measurement, V = 4.457879 V 20:44:48 Temperature Measurement, Probe Number = 0, T = 26.287000 C 20:44:50 Temperature Measurement, Probe Number = 1, T = 27.991000 C 20:44:52 Temperature Measurement, Probe Number = 2, T = 27.848000 C 20:44:54 Temperature Measurement, Probe Number = 3, T = 22.744000 C 20:44:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328535 V 20:44:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328535 (V, A, ohm, ...), Measured Value = 28.451876 (C, atm, Hz, ...) 20:44:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.343502 V 20:44:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343502 (V, A, ohm, ...), Measured Value = 28.659749 (C, atm, Hz, ...) 20:45:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274818 V 20:45:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274818 (V, A, ohm, ...), Measured Value = 95.611313 (C, atm, Hz, ...) 20:45:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092233 V 20:45:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092233 (V, A, ohm, ...), Measured Value = 6.917505 (C, atm, Hz, ...) 20:45:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 20:45:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893059 (C, atm, Hz, ...) 20:45:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.29 P3 = Right Coil Outgoing Side, Value = 27.99 P4 = Left Coil Middle, Value = 27.85 P5 = Ambient, Value = 22.74 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.66 P8 = Supply Pres(psi), Value = 95.61 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.89 20:45:11 Magnet system MAIN current ramping to 0.0000 A... 20:46:35 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:46:37 Main (V) Voltage Measurement, V = 0.000001 V 20:46:42 Temperature Measurement, Probe Number = 0, T = 26.279000 C 20:46:44 Temperature Measurement, Probe Number = 1, T = 28.130000 C 20:46:46 Temperature Measurement, Probe Number = 2, T = 27.862000 C 20:46:48 Temperature Measurement, Probe Number = 3, T = 22.698000 C 20:46:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328454 V 20:46:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328454 (V, A, ohm, ...), Measured Value = 28.450746 (C, atm, Hz, ...) 20:46:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353218 V 20:46:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353218 (V, A, ohm, ...), Measured Value = 28.794693 (C, atm, Hz, ...) 20:46:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267592 V 20:46:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267592 (V, A, ohm, ...), Measured Value = 95.069385 (C, atm, Hz, ...) 20:46:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092302 V 20:46:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092302 (V, A, ohm, ...), Measured Value = 6.922643 (C, atm, Hz, ...) 20:47:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000877 V 20:47:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000877 (V, A, ohm, ...), Measured Value = 0.877221 (C, atm, Hz, ...) 20:47:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.28 P3 = Right Coil Outgoing Side, Value = 28.13 P4 = Left Coil Middle, Value = 27.86 P5 = Ambient, Value = 22.70 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.07 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.88 20:47:05 Magnet system MAIN current ramping to 125.0000 A... 20:48:29 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:48:31 Main (V) Voltage Measurement, V = 4.458122 V 20:48:36 Temperature Measurement, Probe Number = 0, T = 26.279000 C 20:48:38 Temperature Measurement, Probe Number = 1, T = 27.907000 C 20:48:40 Temperature Measurement, Probe Number = 2, T = 27.769000 C 20:48:42 Temperature Measurement, Probe Number = 3, T = 22.667000 C 20:48:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328700 V 20:48:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328700 (V, A, ohm, ...), Measured Value = 28.454172 (C, atm, Hz, ...) 20:48:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.350775 V 20:48:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350775 (V, A, ohm, ...), Measured Value = 28.760769 (C, atm, Hz, ...) 20:48:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263972 V 20:48:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263972 (V, A, ohm, ...), Measured Value = 94.797937 (C, atm, Hz, ...) 20:48:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092311 V 20:48:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092311 (V, A, ohm, ...), Measured Value = 6.923317 (C, atm, Hz, ...) 20:48:59 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 20:48:59 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900359 (C, atm, Hz, ...) 20:48:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.28 P3 = Right Coil Outgoing Side, Value = 27.91 P4 = Left Coil Middle, Value = 27.77 P5 = Ambient, Value = 22.67 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.76 P8 = Supply Pres(psi), Value = 94.80 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.90 20:48:59 Magnet system MAIN current ramping to 0.0000 A... 20:50:23 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:50:25 Main (V) Voltage Measurement, V = 0.000005 V 20:50:30 Temperature Measurement, Probe Number = 0, T = 26.271000 C 20:50:32 Temperature Measurement, Probe Number = 1, T = 28.109000 C 20:50:34 Temperature Measurement, Probe Number = 2, T = 27.908000 C 20:50:37 Temperature Measurement, Probe Number = 3, T = 22.679000 C 20:50:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328427 V 20:50:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328427 (V, A, ohm, ...), Measured Value = 28.450369 (C, atm, Hz, ...) 20:50:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.351911 V 20:50:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351911 (V, A, ohm, ...), Measured Value = 28.776539 (C, atm, Hz, ...) 20:50:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271289 V 20:50:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271289 (V, A, ohm, ...), Measured Value = 95.346645 (C, atm, Hz, ...) 20:50:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092170 V 20:50:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092170 (V, A, ohm, ...), Measured Value = 6.912757 (C, atm, Hz, ...) 20:50:53 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 20:50:53 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890829 (C, atm, Hz, ...) 20:50:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.27 P3 = Right Coil Outgoing Side, Value = 28.11 P4 = Left Coil Middle, Value = 27.91 P5 = Ambient, Value = 22.68 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.78 P8 = Supply Pres(psi), Value = 95.35 P9 = Return Pres(psi), Value = 6.91 P10 = Flow Rate(gpm), Value = 0.89 20:50:53 Magnet system MAIN current ramping to 125.0000 A... 20:52:18 Magnet Current for MAIN, Imag = 124.9919 A Vtrans = 1.249918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:52:20 Main (V) Voltage Measurement, V = 4.458468 V 20:52:25 Temperature Measurement, Probe Number = 0, T = 26.286000 C 20:52:27 Temperature Measurement, Probe Number = 1, T = 27.891000 C 20:52:29 Temperature Measurement, Probe Number = 2, T = 27.834000 C 20:52:31 Temperature Measurement, Probe Number = 3, T = 22.723000 C 20:52:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.328211 V 20:52:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328211 (V, A, ohm, ...), Measured Value = 28.447374 (C, atm, Hz, ...) 20:52:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.350245 V 20:52:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350245 (V, A, ohm, ...), Measured Value = 28.753396 (C, atm, Hz, ...) 20:52:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264301 V 20:52:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264301 (V, A, ohm, ...), Measured Value = 94.822545 (C, atm, Hz, ...) 20:52:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092434 V 20:52:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092434 (V, A, ohm, ...), Measured Value = 6.932520 (C, atm, Hz, ...) 20:52:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 20:52:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878163 (C, atm, Hz, ...) 20:52:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.29 P3 = Right Coil Outgoing Side, Value = 27.89 P4 = Left Coil Middle, Value = 27.83 P5 = Ambient, Value = 22.72 P6 = Supply Temp(C), Value = 28.45 P7 = Return Temp(C), Value = 28.75 P8 = Supply Pres(psi), Value = 94.82 P9 = Return Pres(psi), Value = 6.93 P10 = Flow Rate(gpm), Value = 0.88 20:52:48 Magnet system MAIN current ramping to 0.0000 A... 20:54:12 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:54:14 Main (V) Voltage Measurement, V = 0.000000 V 20:54:19 Temperature Measurement, Probe Number = 0, T = 26.261000 C 20:54:21 Temperature Measurement, Probe Number = 1, T = 28.114000 C 20:54:23 Temperature Measurement, Probe Number = 2, T = 27.868000 C 20:54:25 Temperature Measurement, Probe Number = 3, T = 22.767000 C 20:54:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.327916 V 20:54:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327916 (V, A, ohm, ...), Measured Value = 28.443283 (C, atm, Hz, ...) 20:54:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.351691 V 20:54:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351691 (V, A, ohm, ...), Measured Value = 28.773489 (C, atm, Hz, ...) 20:54:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268670 V 20:54:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268670 (V, A, ohm, ...), Measured Value = 95.150280 (C, atm, Hz, ...) 20:54:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092122 V 20:54:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092122 (V, A, ohm, ...), Measured Value = 6.909172 (C, atm, Hz, ...) 20:54:42 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 20:54:42 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895745 (C, atm, Hz, ...) 20:54:42 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.26 P3 = Right Coil Outgoing Side, Value = 28.11 P4 = Left Coil Middle, Value = 27.87 P5 = Ambient, Value = 22.77 P6 = Supply Temp(C), Value = 28.44 P7 = Return Temp(C), Value = 28.77 P8 = Supply Pres(psi), Value = 95.15 P9 = Return Pres(psi), Value = 6.91 P10 = Flow Rate(gpm), Value = 0.90 20:54:42 Magnet system MAIN current ramping to 125.0000 A... 20:56:06 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:56:08 Main (V) Voltage Measurement, V = 4.458303 V 20:56:13 Temperature Measurement, Probe Number = 0, T = 26.251000 C 20:56:15 Temperature Measurement, Probe Number = 1, T = 27.890000 C 20:56:17 Temperature Measurement, Probe Number = 2, T = 27.777000 C 20:56:19 Temperature Measurement, Probe Number = 3, T = 22.735000 C 20:56:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.327609 V 20:56:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327609 (V, A, ohm, ...), Measured Value = 28.439013 (C, atm, Hz, ...) 20:56:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.349945 V 20:56:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349945 (V, A, ohm, ...), Measured Value = 28.749233 (C, atm, Hz, ...) 20:56:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268001 V 20:56:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268001 (V, A, ohm, ...), Measured Value = 95.100097 (C, atm, Hz, ...) 20:56:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092192 V 20:56:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092192 (V, A, ohm, ...), Measured Value = 6.914408 (C, atm, Hz, ...) 20:56:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 20:56:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880998 (C, atm, Hz, ...) 20:56:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.25 P3 = Right Coil Outgoing Side, Value = 27.89 P4 = Left Coil Middle, Value = 27.78 P5 = Ambient, Value = 22.73 P6 = Supply Temp(C), Value = 28.44 P7 = Return Temp(C), Value = 28.75 P8 = Supply Pres(psi), Value = 95.10 P9 = Return Pres(psi), Value = 6.91 P10 = Flow Rate(gpm), Value = 0.88 20:56:36 Magnet system MAIN current ramping to 0.0000 A... 20:58:00 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:58:02 Main (V) Voltage Measurement, V = 0.000003 V 20:58:07 Temperature Measurement, Probe Number = 0, T = 26.284000 C 20:58:09 Temperature Measurement, Probe Number = 1, T = 28.104000 C 20:58:11 Temperature Measurement, Probe Number = 2, T = 27.891000 C 20:58:13 Temperature Measurement, Probe Number = 3, T = 22.689000 C 20:58:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.327792 V 20:58:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327792 (V, A, ohm, ...), Measured Value = 28.441561 (C, atm, Hz, ...) 20:58:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.350983 V 20:58:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350983 (V, A, ohm, ...), Measured Value = 28.763657 (C, atm, Hz, ...) 20:58:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264550 V 20:58:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264550 (V, A, ohm, ...), Measured Value = 94.841243 (C, atm, Hz, ...) 20:58:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092236 V 20:58:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092236 (V, A, ohm, ...), Measured Value = 6.917700 (C, atm, Hz, ...) 20:58:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 20:58:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885631 (C, atm, Hz, ...) 20:58:30 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.28 P3 = Right Coil Outgoing Side, Value = 28.10 P4 = Left Coil Middle, Value = 27.89 P5 = Ambient, Value = 22.69 P6 = Supply Temp(C), Value = 28.44 P7 = Return Temp(C), Value = 28.76 P8 = Supply Pres(psi), Value = 94.84 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.89 20:58:30 Magnet system MAIN current ramping to 75.0000 A... 20:59:26 Magnet Current for MAIN, Imag = 75.0214 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 20:59:28 Main (V) Voltage Measurement, V = 2.669804 V 20:59:33 Temperature Measurement, Probe Number = 0, T = 26.249000 C 20:59:35 Temperature Measurement, Probe Number = 1, T = 27.857000 C 20:59:38 Temperature Measurement, Probe Number = 2, T = 27.683000 C 20:59:40 Temperature Measurement, Probe Number = 3, T = 22.725000 C 20:59:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.327981 V 20:59:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327981 (V, A, ohm, ...), Measured Value = 28.444179 (C, atm, Hz, ...) 20:59:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.352942 V 20:59:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352942 (V, A, ohm, ...), Measured Value = 28.790854 (C, atm, Hz, ...) 20:59:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270922 V 20:59:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270922 (V, A, ohm, ...), Measured Value = 95.319135 (C, atm, Hz, ...) 20:59:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092210 V 20:59:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092210 (V, A, ohm, ...), Measured Value = 6.915765 (C, atm, Hz, ...) 20:59:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 20:59:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887823 (C, atm, Hz, ...) 20:59:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.25 P3 = Right Coil Outgoing Side, Value = 27.86 P4 = Left Coil Middle, Value = 27.68 P5 = Ambient, Value = 22.73 P6 = Supply Temp(C), Value = 28.44 P7 = Return Temp(C), Value = 28.79 P8 = Supply Pres(psi), Value = 95.32 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.89 20:59:56 Magnetic Field Measurement Measuring the magnet strength... 20:59:56 Integrated Voltage Measurement... 20:59:58 Magnet Current for MAIN, Imag = 75.0210 A Vtrans = 0.750209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:00:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397990 Vs 21:00:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014408452 Vs 21:00:20 Magnet Current for MAIN, Imag = 75.0215 A Vtrans = 0.750215 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:00:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402962 Vs 21:00:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014406273 Vs 21:00:41 Magnet Current for MAIN, Imag = 75.0217 A Vtrans = 0.750216 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:00:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403238 Vs 21:00:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405465 Vs 21:01:01 Magnet Current for MAIN, Imag = 75.0215 A Vtrans = 0.750215 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:01:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402008 Vs 21:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014404673 Vs 21:01:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403883 +- 0.000000611 Vs 21:01:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403883 +- 0.000000611 Vs BL = -0.16004314 +- 0.00000678 Tm 21:01:24 Position moved: 0.000000 m 21:01:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 21:01:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600431 +- 0.0000068 Tm^2/m^n 21:01:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600431 +- 0.0000068 Tm^2/m^n 21:01:27 Position moved: 0.000000 m 21:01:27 Magnet system MAIN current ramping to 125.0000 A... 21:02:06 Magnet system MAIN current ramping to 0.0000 A... 21:03:28 Magnet system MAIN current ramping to 125.0000 A... 21:04:50 Magnet system MAIN current ramping to 0.0000 A... 21:06:12 Magnet system MAIN current ramping to 125.0000 A... 21:07:33 Magnet system MAIN current ramping to 0.0000 A... 21:08:57 Position moved: 0.000000 m 21:09:00 Magnet system MAIN current ramping to 87.5000 A... 21:10:03 Magnet Current for MAIN, Imag = 87.4676 A Vtrans = 0.874675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:10:05 Main (V) Voltage Measurement, V = 3.114143 V 21:10:10 Temperature Measurement, Probe Number = 0, T = 26.261000 C 21:10:12 Temperature Measurement, Probe Number = 1, T = 27.851000 C 21:10:15 Temperature Measurement, Probe Number = 2, T = 27.747000 C 21:10:17 Temperature Measurement, Probe Number = 3, T = 22.565000 C 21:10:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326746 V 21:10:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326746 (V, A, ohm, ...), Measured Value = 28.427029 (C, atm, Hz, ...) 21:10:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.345247 V 21:10:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345247 (V, A, ohm, ...), Measured Value = 28.683985 (C, atm, Hz, ...) 21:10:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274344 V 21:10:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274344 (V, A, ohm, ...), Measured Value = 95.575763 (C, atm, Hz, ...) 21:10:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092333 V 21:10:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092333 (V, A, ohm, ...), Measured Value = 6.924967 (C, atm, Hz, ...) 21:10:33 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000912 V 21:10:33 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000912 (V, A, ohm, ...), Measured Value = 0.912166 (C, atm, Hz, ...) 21:10:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.26 P3 = Right Coil Outgoing Side, Value = 27.85 P4 = Left Coil Middle, Value = 27.75 P5 = Ambient, Value = 22.57 P6 = Supply Temp(C), Value = 28.43 P7 = Return Temp(C), Value = 28.68 P8 = Supply Pres(psi), Value = 95.58 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.91 21:10:33 Magnetic Field Measurement Measuring the magnet strength... 21:10:33 Integrated Voltage Measurement... 21:10:35 Magnet Current for MAIN, Imag = 87.4678 A Vtrans = 0.874677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:10:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781932 Vs 21:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777208 Vs 21:10:57 Magnet Current for MAIN, Imag = 87.4680 A Vtrans = 0.874679 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:11:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775982 Vs 21:11:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779937 Vs 21:11:18 Magnet Current for MAIN, Imag = 87.4679 A Vtrans = 0.874678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776702 Vs 21:11:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016780662 Vs 21:11:39 Magnet Current for MAIN, Imag = 87.4676 A Vtrans = 0.874675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:11:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774305 Vs 21:11:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779160 Vs 21:11:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778236 +- 0.000001039 Vs 21:11:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016778236 +- 0.000001039 Vs BL = -0.18642484 +- 0.00001154 Tm 21:12:01 Position moved: 0.000000 m 21:12:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18642 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18642 0.00001 -0.18642 0.00000 21:12:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18642 0.00001 SL = -0.1864248 +- 0.0000115 Tm^2/m^n 21:12:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864248 +- 0.0000115 Tm^2/m^n 21:12:04 Position moved: 0.000000 m 21:12:04 Magnet system MAIN current ramping to 75.0000 A... 21:12:25 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:12:27 Main (V) Voltage Measurement, V = 2.672762 V 21:12:32 Temperature Measurement, Probe Number = 0, T = 26.246000 C 21:12:34 Temperature Measurement, Probe Number = 1, T = 27.900000 C 21:12:36 Temperature Measurement, Probe Number = 2, T = 27.846000 C 21:12:38 Temperature Measurement, Probe Number = 3, T = 22.529000 C 21:12:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326577 V 21:12:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326577 (V, A, ohm, ...), Measured Value = 28.424679 (C, atm, Hz, ...) 21:12:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338282 V 21:12:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338282 (V, A, ohm, ...), Measured Value = 28.587253 (C, atm, Hz, ...) 21:12:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266640 V 21:12:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266640 (V, A, ohm, ...), Measured Value = 94.997992 (C, atm, Hz, ...) 21:12:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092279 V 21:12:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092279 (V, A, ohm, ...), Measured Value = 6.920895 (C, atm, Hz, ...) 21:12:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 21:12:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895926 (C, atm, Hz, ...) 21:12:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.25 P3 = Right Coil Outgoing Side, Value = 27.90 P4 = Left Coil Middle, Value = 27.85 P5 = Ambient, Value = 22.53 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.59 P8 = Supply Pres(psi), Value = 95.00 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.90 21:12:55 Magnet system MAIN current ramping to 125.0000 A... 21:13:36 Magnet Current for MAIN, Imag = 124.9906 A Vtrans = 1.249905 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:13:38 Main (V) Voltage Measurement, V = 4.457359 V 21:13:44 Temperature Measurement, Probe Number = 0, T = 26.248000 C 21:13:46 Temperature Measurement, Probe Number = 1, T = 27.952000 C 21:13:48 Temperature Measurement, Probe Number = 2, T = 27.868000 C 21:13:50 Temperature Measurement, Probe Number = 3, T = 22.577000 C 21:13:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326579 V 21:13:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326579 (V, A, ohm, ...), Measured Value = 28.424715 (C, atm, Hz, ...) 21:13:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340514 V 21:13:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340514 (V, A, ohm, ...), Measured Value = 28.618253 (C, atm, Hz, ...) 21:13:56 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264564 V 21:13:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264564 (V, A, ohm, ...), Measured Value = 94.842307 (C, atm, Hz, ...) 21:13:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092498 V 21:13:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092498 (V, A, ohm, ...), Measured Value = 6.937365 (C, atm, Hz, ...) 21:14:06 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 21:14:06 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877818 (C, atm, Hz, ...) 21:14:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.25 P3 = Right Coil Outgoing Side, Value = 27.95 P4 = Left Coil Middle, Value = 27.87 P5 = Ambient, Value = 22.58 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.62 P8 = Supply Pres(psi), Value = 94.84 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.88 21:14:06 Magnet system MAIN current ramping to 0.0000 A... 21:15:30 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:15:32 Main (V) Voltage Measurement, V = -0.000003 V 21:15:37 Temperature Measurement, Probe Number = 0, T = 26.240000 C 21:15:39 Temperature Measurement, Probe Number = 1, T = 28.085000 C 21:15:41 Temperature Measurement, Probe Number = 2, T = 27.861000 C 21:15:44 Temperature Measurement, Probe Number = 3, T = 22.511000 C 21:15:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326683 V 21:15:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326683 (V, A, ohm, ...), Measured Value = 28.426150 (C, atm, Hz, ...) 21:15:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.349840 V 21:15:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349840 (V, A, ohm, ...), Measured Value = 28.747781 (C, atm, Hz, ...) 21:15:50 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264466 V 21:15:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264466 (V, A, ohm, ...), Measured Value = 94.834950 (C, atm, Hz, ...) 21:15:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092430 V 21:15:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092430 (V, A, ohm, ...), Measured Value = 6.932235 (C, atm, Hz, ...) 21:16:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 21:16:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880786 (C, atm, Hz, ...) 21:16:00 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.24 P3 = Right Coil Outgoing Side, Value = 28.09 P4 = Left Coil Middle, Value = 27.86 P5 = Ambient, Value = 22.51 P6 = Supply Temp(C), Value = 28.43 P7 = Return Temp(C), Value = 28.75 P8 = Supply Pres(psi), Value = 94.83 P9 = Return Pres(psi), Value = 6.93 P10 = Flow Rate(gpm), Value = 0.88 21:16:00 Magnet system MAIN current ramping to 125.0000 A... 21:17:24 Magnet Current for MAIN, Imag = 124.9910 A Vtrans = 1.249909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:17:26 Main (V) Voltage Measurement, V = 4.457955 V 21:17:31 Temperature Measurement, Probe Number = 0, T = 26.235000 C 21:17:34 Temperature Measurement, Probe Number = 1, T = 27.852000 C 21:17:36 Temperature Measurement, Probe Number = 2, T = 27.773000 C 21:17:38 Temperature Measurement, Probe Number = 3, T = 22.553000 C 21:17:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326450 V 21:17:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326450 (V, A, ohm, ...), Measured Value = 28.422921 (C, atm, Hz, ...) 21:17:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.346927 V 21:17:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346927 (V, A, ohm, ...), Measured Value = 28.707325 (C, atm, Hz, ...) 21:17:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267864 V 21:17:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267864 (V, A, ohm, ...), Measured Value = 95.089830 (C, atm, Hz, ...) 21:17:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092360 V 21:17:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092360 (V, A, ohm, ...), Measured Value = 6.927000 (C, atm, Hz, ...) 21:17:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 21:17:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.902991 (C, atm, Hz, ...) 21:17:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.23 P3 = Right Coil Outgoing Side, Value = 27.85 P4 = Left Coil Middle, Value = 27.77 P5 = Ambient, Value = 22.55 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.71 P8 = Supply Pres(psi), Value = 95.09 P9 = Return Pres(psi), Value = 6.93 P10 = Flow Rate(gpm), Value = 0.90 21:17:54 Magnet system MAIN current ramping to 0.0000 A... 21:19:18 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:19:20 Main (V) Voltage Measurement, V = -0.000001 V 21:19:25 Temperature Measurement, Probe Number = 0, T = 26.221000 C 21:19:27 Temperature Measurement, Probe Number = 1, T = 28.061000 C 21:19:30 Temperature Measurement, Probe Number = 2, T = 27.836000 C 21:19:32 Temperature Measurement, Probe Number = 3, T = 22.557000 C 21:19:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326338 V 21:19:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326338 (V, A, ohm, ...), Measured Value = 28.421360 (C, atm, Hz, ...) 21:19:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.348602 V 21:19:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348602 (V, A, ohm, ...), Measured Value = 28.730576 (C, atm, Hz, ...) 21:19:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272283 V 21:19:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272283 (V, A, ohm, ...), Measured Value = 95.421240 (C, atm, Hz, ...) 21:19:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092483 V 21:19:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092483 (V, A, ohm, ...), Measured Value = 6.936202 (C, atm, Hz, ...) 21:19:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 21:19:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.872838 (C, atm, Hz, ...) 21:19:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.84 P5 = Ambient, Value = 22.56 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.73 P8 = Supply Pres(psi), Value = 95.42 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.87 21:19:48 Magnet system MAIN current ramping to 125.0000 A... 21:21:12 Magnet Current for MAIN, Imag = 124.9899 A Vtrans = 1.249898 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:21:14 Main (V) Voltage Measurement, V = 4.457946 V 21:21:19 Temperature Measurement, Probe Number = 0, T = 26.217000 C 21:21:21 Temperature Measurement, Probe Number = 1, T = 27.857000 C 21:21:23 Temperature Measurement, Probe Number = 2, T = 27.806000 C 21:21:25 Temperature Measurement, Probe Number = 3, T = 22.573000 C 21:21:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326430 V 21:21:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326430 (V, A, ohm, ...), Measured Value = 28.422633 (C, atm, Hz, ...) 21:21:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.346890 V 21:21:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346890 (V, A, ohm, ...), Measured Value = 28.706806 (C, atm, Hz, ...) 21:21:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264419 V 21:21:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264419 (V, A, ohm, ...), Measured Value = 94.831462 (C, atm, Hz, ...) 21:21:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092728 V 21:21:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092728 (V, A, ohm, ...), Measured Value = 6.954607 (C, atm, Hz, ...) 21:21:42 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 21:21:42 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.889179 (C, atm, Hz, ...) 21:21:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 27.86 P4 = Left Coil Middle, Value = 27.81 P5 = Ambient, Value = 22.57 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.71 P8 = Supply Pres(psi), Value = 94.83 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.89 21:21:42 Magnet system MAIN current ramping to 0.0000 A... 21:23:06 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:23:08 Main (V) Voltage Measurement, V = -0.000003 V 21:23:13 Temperature Measurement, Probe Number = 0, T = 26.224000 C 21:23:15 Temperature Measurement, Probe Number = 1, T = 28.064000 C 21:23:18 Temperature Measurement, Probe Number = 2, T = 27.882000 C 21:23:20 Temperature Measurement, Probe Number = 3, T = 22.522000 C 21:23:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326570 V 21:23:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326570 (V, A, ohm, ...), Measured Value = 28.424589 (C, atm, Hz, ...) 21:23:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.348724 V 21:23:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348724 (V, A, ohm, ...), Measured Value = 28.732281 (C, atm, Hz, ...) 21:23:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272952 V 21:23:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272952 (V, A, ohm, ...), Measured Value = 95.471423 (C, atm, Hz, ...) 21:23:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092593 V 21:23:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092593 (V, A, ohm, ...), Measured Value = 6.944438 (C, atm, Hz, ...) 21:23:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 21:23:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885441 (C, atm, Hz, ...) 21:23:36 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.88 P5 = Ambient, Value = 22.52 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.73 P8 = Supply Pres(psi), Value = 95.47 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.89 21:23:36 Magnet system MAIN current ramping to 125.0000 A... 21:25:00 Magnet Current for MAIN, Imag = 124.9907 A Vtrans = 1.249906 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:25:03 Main (V) Voltage Measurement, V = 4.457794 V 21:25:08 Temperature Measurement, Probe Number = 0, T = 26.222000 C 21:25:10 Temperature Measurement, Probe Number = 1, T = 27.837000 C 21:25:12 Temperature Measurement, Probe Number = 2, T = 27.830000 C 21:25:14 Temperature Measurement, Probe Number = 3, T = 22.533000 C 21:25:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326276 V 21:25:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326276 (V, A, ohm, ...), Measured Value = 28.420499 (C, atm, Hz, ...) 21:25:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.346864 V 21:25:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346864 (V, A, ohm, ...), Measured Value = 28.706446 (C, atm, Hz, ...) 21:25:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267813 V 21:25:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267813 (V, A, ohm, ...), Measured Value = 95.085952 (C, atm, Hz, ...) 21:25:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092270 V 21:25:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092270 (V, A, ohm, ...), Measured Value = 6.920220 (C, atm, Hz, ...) 21:25:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 21:25:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893097 (C, atm, Hz, ...) 21:25:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 27.84 P4 = Left Coil Middle, Value = 27.83 P5 = Ambient, Value = 22.53 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.71 P8 = Supply Pres(psi), Value = 95.09 P9 = Return Pres(psi), Value = 6.92 P10 = Flow Rate(gpm), Value = 0.89 21:25:30 Magnet system MAIN current ramping to 0.0000 A... 21:26:54 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:26:56 Main (V) Voltage Measurement, V = 0.000001 V 21:27:01 Temperature Measurement, Probe Number = 0, T = 26.219000 C 21:27:03 Temperature Measurement, Probe Number = 1, T = 28.058000 C 21:27:05 Temperature Measurement, Probe Number = 2, T = 27.913000 C 21:27:07 Temperature Measurement, Probe Number = 3, T = 22.539000 C 21:27:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326523 V 21:27:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326523 (V, A, ohm, ...), Measured Value = 28.423925 (C, atm, Hz, ...) 21:27:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.347805 V 21:27:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347805 (V, A, ohm, ...), Measured Value = 28.719507 (C, atm, Hz, ...) 21:27:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270577 V 21:27:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270577 (V, A, ohm, ...), Measured Value = 95.293267 (C, atm, Hz, ...) 21:27:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092499 V 21:27:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092499 (V, A, ohm, ...), Measured Value = 6.937462 (C, atm, Hz, ...) 21:27:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 21:27:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877808 (C, atm, Hz, ...) 21:27:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.22 P3 = Right Coil Outgoing Side, Value = 28.06 P4 = Left Coil Middle, Value = 27.91 P5 = Ambient, Value = 22.54 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.72 P8 = Supply Pres(psi), Value = 95.29 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.88 21:27:24 Magnet system MAIN current ramping to 75.0000 A... 21:28:19 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:28:21 Main (V) Voltage Measurement, V = 2.669582 V 21:28:26 Temperature Measurement, Probe Number = 0, T = 26.212000 C 21:28:28 Temperature Measurement, Probe Number = 1, T = 27.803000 C 21:28:31 Temperature Measurement, Probe Number = 2, T = 27.652000 C 21:28:33 Temperature Measurement, Probe Number = 3, T = 22.494000 C 21:28:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325910 V 21:28:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325910 (V, A, ohm, ...), Measured Value = 28.415422 (C, atm, Hz, ...) 21:28:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.350071 V 21:28:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350071 (V, A, ohm, ...), Measured Value = 28.750992 (C, atm, Hz, ...) 21:28:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272239 V 21:28:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272239 (V, A, ohm, ...), Measured Value = 95.417947 (C, atm, Hz, ...) 21:28:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092658 V 21:28:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092658 (V, A, ohm, ...), Measured Value = 6.949380 (C, atm, Hz, ...) 21:28:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000868 V 21:28:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000868 (V, A, ohm, ...), Measured Value = 0.867933 (C, atm, Hz, ...) 21:28:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.21 P3 = Right Coil Outgoing Side, Value = 27.80 P4 = Left Coil Middle, Value = 27.65 P5 = Ambient, Value = 22.49 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.75 P8 = Supply Pres(psi), Value = 95.42 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.87 21:28:49 Magnetic Field Measurement Measuring the magnet strength... 21:28:49 Integrated Voltage Measurement... 21:28:51 Magnet Current for MAIN, Imag = 75.0213 A Vtrans = 0.750212 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400922 Vs 21:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405100 Vs 21:29:13 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401794 Vs 21:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405573 Vs 21:29:34 Magnet Current for MAIN, Imag = 75.0204 A Vtrans = 0.750203 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403628 Vs 21:29:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014404215 Vs 21:29:55 Magnet Current for MAIN, Imag = 75.0210 A Vtrans = 0.750209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403847 Vs 21:30:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401665 Vs 21:30:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403343 +- 0.000000476 Vs 21:30:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403343 +- 0.000000476 Vs BL = -0.16003714 +- 0.00000529 Tm 21:30:18 Position moved: 0.000000 m 21:30:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 21:30:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600371 +- 0.0000053 Tm^2/m^n 21:30:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600371 +- 0.0000053 Tm^2/m^n 21:30:21 Position moved: 0.000000 m 21:30:21 Magnet system MAIN current ramping to 125.0000 A... 21:31:00 Magnet system MAIN current ramping to 0.0000 A... 21:32:22 Magnet system MAIN current ramping to 125.0000 A... 21:33:44 Magnet system MAIN current ramping to 0.0000 A... 21:35:05 Magnet system MAIN current ramping to 125.0000 A... 21:36:27 Magnet system MAIN current ramping to 0.0000 A... 21:37:52 Position moved: 0.000000 m 21:37:55 Magnet system MAIN current ramping to 87.5000 A... 21:38:57 Magnet Current for MAIN, Imag = 87.4676 A Vtrans = 0.874675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:39:00 Main (V) Voltage Measurement, V = 3.113967 V 21:39:05 Temperature Measurement, Probe Number = 0, T = 26.164000 C 21:39:07 Temperature Measurement, Probe Number = 1, T = 27.792000 C 21:39:09 Temperature Measurement, Probe Number = 2, T = 27.656000 C 21:39:11 Temperature Measurement, Probe Number = 3, T = 22.486000 C 21:39:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325974 V 21:39:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325974 (V, A, ohm, ...), Measured Value = 28.416301 (C, atm, Hz, ...) 21:39:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.341449 V 21:39:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341449 (V, A, ohm, ...), Measured Value = 28.631242 (C, atm, Hz, ...) 21:39:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268905 V 21:39:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268905 (V, A, ohm, ...), Measured Value = 95.167912 (C, atm, Hz, ...) 21:39:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092651 V 21:39:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092651 (V, A, ohm, ...), Measured Value = 6.948795 (C, atm, Hz, ...) 21:39:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 21:39:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880030 (C, atm, Hz, ...) 21:39:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.16 P3 = Right Coil Outgoing Side, Value = 27.79 P4 = Left Coil Middle, Value = 27.66 P5 = Ambient, Value = 22.49 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.63 P8 = Supply Pres(psi), Value = 95.17 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.88 21:39:27 Magnetic Field Measurement Measuring the magnet strength... 21:39:27 Integrated Voltage Measurement... 21:39:30 Magnet Current for MAIN, Imag = 87.4674 A Vtrans = 0.874673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:39:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775585 Vs 21:39:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016781589 Vs 21:39:52 Magnet Current for MAIN, Imag = 87.4672 A Vtrans = 0.874672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:40:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775267 Vs 21:40:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777452 Vs 21:40:13 Magnet Current for MAIN, Imag = 87.4678 A Vtrans = 0.874677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:40:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773714 Vs 21:40:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775677 Vs 21:40:33 Magnet Current for MAIN, Imag = 87.4675 A Vtrans = 0.874674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:40:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775796 Vs 21:40:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777621 Vs 21:40:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776588 +- 0.000001382 Vs 21:40:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776588 +- 0.000001382 Vs BL = -0.18640653 +- 0.00001536 Tm 21:40:56 Position moved: 0.000000 m 21:40:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00002 -0.18641 0.00000 21:40:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00002 SL = -0.1864065 +- 0.0000154 Tm^2/m^n 21:40:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864065 +- 0.0000154 Tm^2/m^n 21:40:59 Position moved: 0.000000 m 21:40:59 Magnet system MAIN current ramping to 75.0000 A... 21:41:19 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:41:21 Main (V) Voltage Measurement, V = 2.672598 V 21:41:26 Temperature Measurement, Probe Number = 0, T = 26.186000 C 21:41:28 Temperature Measurement, Probe Number = 1, T = 27.814000 C 21:41:30 Temperature Measurement, Probe Number = 2, T = 27.770000 C 21:41:32 Temperature Measurement, Probe Number = 3, T = 22.396000 C 21:41:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326315 V 21:41:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326315 (V, A, ohm, ...), Measured Value = 28.421038 (C, atm, Hz, ...) 21:41:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.335124 V 21:41:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335124 (V, A, ohm, ...), Measured Value = 28.543389 (C, atm, Hz, ...) 21:41:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266349 V 21:41:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266349 (V, A, ohm, ...), Measured Value = 94.976190 (C, atm, Hz, ...) 21:41:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092510 V 21:41:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092510 (V, A, ohm, ...), Measured Value = 6.938235 (C, atm, Hz, ...) 21:41:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 21:41:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.882739 (C, atm, Hz, ...) 21:41:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.19 P3 = Right Coil Outgoing Side, Value = 27.81 P4 = Left Coil Middle, Value = 27.77 P5 = Ambient, Value = 22.40 P6 = Supply Temp(C), Value = 28.42 P7 = Return Temp(C), Value = 28.54 P8 = Supply Pres(psi), Value = 94.98 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.88 21:41:49 Magnet system MAIN current ramping to 125.0000 A... 21:42:30 Magnet Current for MAIN, Imag = 124.9902 A Vtrans = 1.249901 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:42:33 Main (V) Voltage Measurement, V = 4.457104 V 21:42:38 Temperature Measurement, Probe Number = 0, T = 26.171000 C 21:42:40 Temperature Measurement, Probe Number = 1, T = 27.871000 C 21:42:42 Temperature Measurement, Probe Number = 2, T = 27.828000 C 21:42:44 Temperature Measurement, Probe Number = 3, T = 22.386000 C 21:42:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325828 V 21:42:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325828 (V, A, ohm, ...), Measured Value = 28.414274 (C, atm, Hz, ...) 21:42:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.337966 V 21:42:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337966 (V, A, ohm, ...), Measured Value = 28.582857 (C, atm, Hz, ...) 21:42:50 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272135 V 21:42:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272135 (V, A, ohm, ...), Measured Value = 95.410103 (C, atm, Hz, ...) 21:42:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092593 V 21:42:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092593 (V, A, ohm, ...), Measured Value = 6.944438 (C, atm, Hz, ...) 21:43:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000882 V 21:43:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000882 (V, A, ohm, ...), Measured Value = 0.882213 (C, atm, Hz, ...) 21:43:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.17 P3 = Right Coil Outgoing Side, Value = 27.87 P4 = Left Coil Middle, Value = 27.83 P5 = Ambient, Value = 22.39 P6 = Supply Temp(C), Value = 28.41 P7 = Return Temp(C), Value = 28.58 P8 = Supply Pres(psi), Value = 95.41 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.88 21:43:00 Magnet system MAIN current ramping to 0.0000 A... 21:44:24 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:44:26 Main (V) Voltage Measurement, V = 0.000000 V 21:44:31 Temperature Measurement, Probe Number = 0, T = 26.131000 C 21:44:33 Temperature Measurement, Probe Number = 1, T = 28.022000 C 21:44:36 Temperature Measurement, Probe Number = 2, T = 27.819000 C 21:44:38 Temperature Measurement, Probe Number = 3, T = 22.400000 C 21:44:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325662 V 21:44:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325662 (V, A, ohm, ...), Measured Value = 28.411978 (C, atm, Hz, ...) 21:44:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.347453 V 21:44:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347453 (V, A, ohm, ...), Measured Value = 28.714626 (C, atm, Hz, ...) 21:44:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266951 V 21:44:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266951 (V, A, ohm, ...), Measured Value = 95.021340 (C, atm, Hz, ...) 21:44:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092591 V 21:44:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092591 (V, A, ohm, ...), Measured Value = 6.944340 (C, atm, Hz, ...) 21:44:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000898 V 21:44:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000898 (V, A, ohm, ...), Measured Value = 0.897659 (C, atm, Hz, ...) 21:44:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.13 P3 = Right Coil Outgoing Side, Value = 28.02 P4 = Left Coil Middle, Value = 27.82 P5 = Ambient, Value = 22.40 P6 = Supply Temp(C), Value = 28.41 P7 = Return Temp(C), Value = 28.71 P8 = Supply Pres(psi), Value = 95.02 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.90 21:44:54 Magnet system MAIN current ramping to 125.0000 A... 21:46:18 Magnet Current for MAIN, Imag = 124.9903 A Vtrans = 1.249902 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:46:21 Main (V) Voltage Measurement, V = 4.458138 V 21:46:26 Temperature Measurement, Probe Number = 0, T = 26.169000 C 21:46:28 Temperature Measurement, Probe Number = 1, T = 27.802000 C 21:46:30 Temperature Measurement, Probe Number = 2, T = 27.724000 C 21:46:32 Temperature Measurement, Probe Number = 3, T = 22.397000 C 21:46:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325851 V 21:46:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325851 (V, A, ohm, ...), Measured Value = 28.414596 (C, atm, Hz, ...) 21:46:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.344170 V 21:46:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344170 (V, A, ohm, ...), Measured Value = 28.669024 (C, atm, Hz, ...) 21:46:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267297 V 21:46:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267297 (V, A, ohm, ...), Measured Value = 95.047297 (C, atm, Hz, ...) 21:46:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092766 V 21:46:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092766 (V, A, ohm, ...), Measured Value = 6.957420 (C, atm, Hz, ...) 21:46:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 21:46:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890707 (C, atm, Hz, ...) 21:46:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.17 P3 = Right Coil Outgoing Side, Value = 27.80 P4 = Left Coil Middle, Value = 27.72 P5 = Ambient, Value = 22.40 P6 = Supply Temp(C), Value = 28.41 P7 = Return Temp(C), Value = 28.67 P8 = Supply Pres(psi), Value = 95.05 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.89 21:46:48 Magnet system MAIN current ramping to 0.0000 A... 21:48:12 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:48:14 Main (V) Voltage Measurement, V = 0.000000 V 21:48:19 Temperature Measurement, Probe Number = 0, T = 26.176000 C 21:48:21 Temperature Measurement, Probe Number = 1, T = 28.012000 C 21:48:23 Temperature Measurement, Probe Number = 2, T = 27.854000 C 21:48:25 Temperature Measurement, Probe Number = 3, T = 22.407000 C 21:48:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325423 V 21:48:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325423 (V, A, ohm, ...), Measured Value = 28.408658 (C, atm, Hz, ...) 21:48:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.345154 V 21:48:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345154 (V, A, ohm, ...), Measured Value = 28.682693 (C, atm, Hz, ...) 21:48:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266026 V 21:48:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266026 (V, A, ohm, ...), Measured Value = 94.951973 (C, atm, Hz, ...) 21:48:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092591 V 21:48:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092591 (V, A, ohm, ...), Measured Value = 6.944340 (C, atm, Hz, ...) 21:48:42 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 21:48:42 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887723 (C, atm, Hz, ...) 21:48:42 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.18 P3 = Right Coil Outgoing Side, Value = 28.01 P4 = Left Coil Middle, Value = 27.85 P5 = Ambient, Value = 22.41 P6 = Supply Temp(C), Value = 28.41 P7 = Return Temp(C), Value = 28.68 P8 = Supply Pres(psi), Value = 94.95 P9 = Return Pres(psi), Value = 6.94 P10 = Flow Rate(gpm), Value = 0.89 21:48:42 Magnet system MAIN current ramping to 125.0000 A... 21:50:06 Magnet Current for MAIN, Imag = 124.9903 A Vtrans = 1.249902 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:50:08 Main (V) Voltage Measurement, V = 4.457244 V 21:50:13 Temperature Measurement, Probe Number = 0, T = 26.147000 C 21:50:15 Temperature Measurement, Probe Number = 1, T = 27.790000 C 21:50:17 Temperature Measurement, Probe Number = 2, T = 27.722000 C 21:50:19 Temperature Measurement, Probe Number = 3, T = 22.413000 C 21:50:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324964 V 21:50:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324964 (V, A, ohm, ...), Measured Value = 28.402272 (C, atm, Hz, ...) 21:50:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.343590 V 21:50:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343590 (V, A, ohm, ...), Measured Value = 28.660968 (C, atm, Hz, ...) 21:50:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.257601 V 21:50:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.257601 (V, A, ohm, ...), Measured Value = 94.320045 (C, atm, Hz, ...) 21:50:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092835 V 21:50:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092835 (V, A, ohm, ...), Measured Value = 6.962647 (C, atm, Hz, ...) 21:50:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000876 V 21:50:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000876 (V, A, ohm, ...), Measured Value = 0.875577 (C, atm, Hz, ...) 21:50:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.15 P3 = Right Coil Outgoing Side, Value = 27.79 P4 = Left Coil Middle, Value = 27.72 P5 = Ambient, Value = 22.41 P6 = Supply Temp(C), Value = 28.40 P7 = Return Temp(C), Value = 28.66 P8 = Supply Pres(psi), Value = 94.32 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.88 21:50:35 Magnet system MAIN current ramping to 0.0000 A... 21:52:00 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:52:02 Main (V) Voltage Measurement, V = -0.000001 V 21:52:07 Temperature Measurement, Probe Number = 0, T = 26.159000 C 21:52:09 Temperature Measurement, Probe Number = 1, T = 27.991000 C 21:52:11 Temperature Measurement, Probe Number = 2, T = 27.807000 C 21:52:13 Temperature Measurement, Probe Number = 3, T = 22.438000 C 21:52:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324473 V 21:52:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324473 (V, A, ohm, ...), Measured Value = 28.395454 (C, atm, Hz, ...) 21:52:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.344894 V 21:52:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344894 (V, A, ohm, ...), Measured Value = 28.679087 (C, atm, Hz, ...) 21:52:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.273005 V 21:52:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.273005 (V, A, ohm, ...), Measured Value = 95.475397 (C, atm, Hz, ...) 21:52:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092675 V 21:52:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092675 (V, A, ohm, ...), Measured Value = 6.950640 (C, atm, Hz, ...) 21:52:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 21:52:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880479 (C, atm, Hz, ...) 21:52:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.16 P3 = Right Coil Outgoing Side, Value = 27.99 P4 = Left Coil Middle, Value = 27.81 P5 = Ambient, Value = 22.44 P6 = Supply Temp(C), Value = 28.40 P7 = Return Temp(C), Value = 28.68 P8 = Supply Pres(psi), Value = 95.48 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.88 21:52:30 Magnet system MAIN current ramping to 125.0000 A... 21:53:54 Magnet Current for MAIN, Imag = 124.9859 A Vtrans = 1.249858 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:53:56 Main (V) Voltage Measurement, V = 4.457065 V 21:54:01 Temperature Measurement, Probe Number = 0, T = 26.178000 C 21:54:03 Temperature Measurement, Probe Number = 1, T = 27.773000 C 21:54:05 Temperature Measurement, Probe Number = 2, T = 27.660000 C 21:54:07 Temperature Measurement, Probe Number = 3, T = 22.362000 C 21:54:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324987 V 21:54:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324987 (V, A, ohm, ...), Measured Value = 28.402594 (C, atm, Hz, ...) 21:54:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.343114 V 21:54:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343114 (V, A, ohm, ...), Measured Value = 28.654367 (C, atm, Hz, ...) 21:54:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265122 V 21:54:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265122 (V, A, ohm, ...), Measured Value = 94.884158 (C, atm, Hz, ...) 21:54:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092866 V 21:54:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092866 (V, A, ohm, ...), Measured Value = 6.964973 (C, atm, Hz, ...) 21:54:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000855 V 21:54:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000855 (V, A, ohm, ...), Measured Value = 0.854874 (C, atm, Hz, ...) 21:54:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.18 P3 = Right Coil Outgoing Side, Value = 27.77 P4 = Left Coil Middle, Value = 27.66 P5 = Ambient, Value = 22.36 P6 = Supply Temp(C), Value = 28.40 P7 = Return Temp(C), Value = 28.65 P8 = Supply Pres(psi), Value = 94.88 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.85 21:54:24 Magnet system MAIN current ramping to 0.0000 A... 21:55:47 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:55:50 Main (V) Voltage Measurement, V = 0.000004 V 21:55:55 Temperature Measurement, Probe Number = 0, T = 26.197000 C 21:55:57 Temperature Measurement, Probe Number = 1, T = 27.956000 C 21:55:59 Temperature Measurement, Probe Number = 2, T = 27.684000 C 21:56:01 Temperature Measurement, Probe Number = 3, T = 22.379000 C 21:56:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324726 V 21:56:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324726 (V, A, ohm, ...), Measured Value = 28.398971 (C, atm, Hz, ...) 21:56:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.345304 V 21:56:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345304 (V, A, ohm, ...), Measured Value = 28.684775 (C, atm, Hz, ...) 21:56:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274363 V 21:56:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274363 (V, A, ohm, ...), Measured Value = 95.577217 (C, atm, Hz, ...) 21:56:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092679 V 21:56:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092679 (V, A, ohm, ...), Measured Value = 6.950925 (C, atm, Hz, ...) 21:56:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 21:56:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888117 (C, atm, Hz, ...) 21:56:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.20 P3 = Right Coil Outgoing Side, Value = 27.96 P4 = Left Coil Middle, Value = 27.68 P5 = Ambient, Value = 22.38 P6 = Supply Temp(C), Value = 28.40 P7 = Return Temp(C), Value = 28.68 P8 = Supply Pres(psi), Value = 95.58 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.89 21:56:17 Magnet system MAIN current ramping to 75.0000 A... 21:57:13 Magnet Current for MAIN, Imag = 75.0210 A Vtrans = 0.750209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:57:15 Main (V) Voltage Measurement, V = 2.669288 V 21:57:20 Temperature Measurement, Probe Number = 0, T = 26.186000 C 21:57:22 Temperature Measurement, Probe Number = 1, T = 27.707000 C 21:57:24 Temperature Measurement, Probe Number = 2, T = 27.420000 C 21:57:26 Temperature Measurement, Probe Number = 3, T = 22.323000 C 21:57:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324334 V 21:57:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324334 (V, A, ohm, ...), Measured Value = 28.393535 (C, atm, Hz, ...) 21:57:31 Sensor Voltage Measurement, Sensor Number = 1, V = 2.347321 V 21:57:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347321 (V, A, ohm, ...), Measured Value = 28.712797 (C, atm, Hz, ...) 21:57:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264788 V 21:57:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264788 (V, A, ohm, ...), Measured Value = 94.859070 (C, atm, Hz, ...) 21:57:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092753 V 21:57:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092753 (V, A, ohm, ...), Measured Value = 6.956452 (C, atm, Hz, ...) 21:57:43 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 21:57:43 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892741 (C, atm, Hz, ...) 21:57:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.19 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.42 P5 = Ambient, Value = 22.32 P6 = Supply Temp(C), Value = 28.39 P7 = Return Temp(C), Value = 28.71 P8 = Supply Pres(psi), Value = 94.86 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.89 21:57:43 Magnetic Field Measurement Measuring the magnet strength... 21:57:43 Integrated Voltage Measurement... 21:57:45 Magnet Current for MAIN, Imag = 75.0204 A Vtrans = 0.750203 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:57:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407219 Vs 21:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399193 Vs 21:58:07 Magnet Current for MAIN, Imag = 75.0208 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:58:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408689 Vs 21:58:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402005 Vs 21:58:28 Magnet Current for MAIN, Imag = 75.0212 A Vtrans = 0.750211 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:58:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014409810 Vs 21:58:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014403410 Vs 21:58:49 Magnet Current for MAIN, Imag = 75.0206 A Vtrans = 0.750205 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 21:58:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014410148 Vs 21:59:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402219 Vs 21:59:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405337 +- 0.000001312 Vs 21:59:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014405337 +- 0.000001312 Vs BL = -0.16005930 +- 0.00001457 Tm 21:59:11 Position moved: 0.000000 m 21:59:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16006 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16006 0.00001 -0.16006 0.00000 21:59:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16006 0.00001 SL = -0.1600593 +- 0.0000146 Tm^2/m^n 21:59:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600593 +- 0.0000146 Tm^2/m^n 21:59:14 Position moved: 0.000000 m 21:59:14 Magnet system MAIN current ramping to 125.0000 A... 21:59:53 Magnet system MAIN current ramping to 0.0000 A... 22:01:14 Magnet system MAIN current ramping to 125.0000 A... 22:02:37 Magnet system MAIN current ramping to 0.0000 A... 22:03:58 Magnet system MAIN current ramping to 125.0000 A... 22:05:20 Magnet system MAIN current ramping to 0.0000 A... 22:06:45 Position moved: 0.000000 m 22:06:47 Magnet system MAIN current ramping to 87.5000 A... 22:07:50 Magnet Current for MAIN, Imag = 87.4671 A Vtrans = 0.874670 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:07:52 Main (V) Voltage Measurement, V = 3.113491 V 22:07:57 Temperature Measurement, Probe Number = 0, T = 26.158000 C 22:07:59 Temperature Measurement, Probe Number = 1, T = 27.711000 C 22:08:01 Temperature Measurement, Probe Number = 2, T = 27.515000 C 22:08:03 Temperature Measurement, Probe Number = 3, T = 22.287000 C 22:08:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323981 V 22:08:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323981 (V, A, ohm, ...), Measured Value = 28.388619 (C, atm, Hz, ...) 22:08:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338410 V 22:08:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338410 (V, A, ohm, ...), Measured Value = 28.589028 (C, atm, Hz, ...) 22:08:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272189 V 22:08:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272189 (V, A, ohm, ...), Measured Value = 95.414175 (C, atm, Hz, ...) 22:08:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092735 V 22:08:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092735 (V, A, ohm, ...), Measured Value = 6.955095 (C, atm, Hz, ...) 22:08:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000875 V 22:08:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000875 (V, A, ohm, ...), Measured Value = 0.875022 (C, atm, Hz, ...) 22:08:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.16 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.52 P5 = Ambient, Value = 22.29 P6 = Supply Temp(C), Value = 28.39 P7 = Return Temp(C), Value = 28.59 P8 = Supply Pres(psi), Value = 95.41 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.88 22:08:20 Magnetic Field Measurement Measuring the magnet strength... 22:08:20 Integrated Voltage Measurement... 22:08:22 Magnet Current for MAIN, Imag = 87.4675 A Vtrans = 0.874674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:08:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781235 Vs 22:08:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777286 Vs 22:08:44 Magnet Current for MAIN, Imag = 87.4670 A Vtrans = 0.874669 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:08:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016783330 Vs 22:09:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776365 Vs 22:09:05 Magnet Current for MAIN, Imag = 87.4671 A Vtrans = 0.874670 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:09:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781310 Vs 22:09:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776691 Vs 22:09:25 Magnet Current for MAIN, Imag = 87.4671 A Vtrans = 0.874670 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:09:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782458 Vs 22:09:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777203 Vs 22:09:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779485 +- 0.000000366 Vs 22:09:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016779485 +- 0.000000366 Vs BL = -0.18643872 +- 0.00000407 Tm 22:09:48 Position moved: 0.000000 m 22:09:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18644 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18644 0.00000 -0.18644 0.00000 22:09:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18644 0.00000 SL = -0.1864387 +- 0.0000041 Tm^2/m^n 22:09:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864387 +- 0.0000041 Tm^2/m^n 22:09:50 Position moved: 0.000000 m 22:09:50 Magnet system MAIN current ramping to 75.0000 A... 22:10:11 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:10:13 Main (V) Voltage Measurement, V = 2.672325 V 22:10:18 Temperature Measurement, Probe Number = 0, T = 26.161000 C 22:10:20 Temperature Measurement, Probe Number = 1, T = 27.750000 C 22:10:22 Temperature Measurement, Probe Number = 2, T = 27.580000 C 22:10:24 Temperature Measurement, Probe Number = 3, T = 22.296000 C 22:10:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323791 V 22:10:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323791 (V, A, ohm, ...), Measured Value = 28.385982 (C, atm, Hz, ...) 22:10:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330982 V 22:10:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330982 (V, A, ohm, ...), Measured Value = 28.485854 (C, atm, Hz, ...) 22:10:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259449 V 22:10:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259449 (V, A, ohm, ...), Measured Value = 94.458675 (C, atm, Hz, ...) 22:10:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092758 V 22:10:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092758 (V, A, ohm, ...), Measured Value = 6.956835 (C, atm, Hz, ...) 22:10:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 22:10:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886195 (C, atm, Hz, ...) 22:10:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.16 P3 = Right Coil Outgoing Side, Value = 27.75 P4 = Left Coil Middle, Value = 27.58 P5 = Ambient, Value = 22.30 P6 = Supply Temp(C), Value = 28.39 P7 = Return Temp(C), Value = 28.49 P8 = Supply Pres(psi), Value = 94.46 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.89 22:10:41 Magnet system MAIN current ramping to 125.0000 A... 22:11:23 Magnet Current for MAIN, Imag = 124.9899 A Vtrans = 1.249898 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:11:25 Main (V) Voltage Measurement, V = 4.456671 V 22:11:30 Temperature Measurement, Probe Number = 0, T = 26.145000 C 22:11:32 Temperature Measurement, Probe Number = 1, T = 27.790000 C 22:11:34 Temperature Measurement, Probe Number = 2, T = 27.610000 C 22:11:36 Temperature Measurement, Probe Number = 3, T = 22.361000 C 22:11:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323485 V 22:11:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323485 (V, A, ohm, ...), Measured Value = 28.381731 (C, atm, Hz, ...) 22:11:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333354 V 22:11:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333354 (V, A, ohm, ...), Measured Value = 28.518811 (C, atm, Hz, ...) 22:11:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258722 V 22:11:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258722 (V, A, ohm, ...), Measured Value = 94.404135 (C, atm, Hz, ...) 22:11:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092846 V 22:11:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092846 (V, A, ohm, ...), Measured Value = 6.963428 (C, atm, Hz, ...) 22:11:53 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 22:11:53 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896493 (C, atm, Hz, ...) 22:11:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.14 P3 = Right Coil Outgoing Side, Value = 27.79 P4 = Left Coil Middle, Value = 27.61 P5 = Ambient, Value = 22.36 P6 = Supply Temp(C), Value = 28.38 P7 = Return Temp(C), Value = 28.52 P8 = Supply Pres(psi), Value = 94.40 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.90 22:11:53 Magnet system MAIN current ramping to 0.0000 A... 22:13:17 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:13:19 Main (V) Voltage Measurement, V = -0.000004 V 22:13:24 Temperature Measurement, Probe Number = 0, T = 26.137000 C 22:13:26 Temperature Measurement, Probe Number = 1, T = 27.916000 C 22:13:28 Temperature Measurement, Probe Number = 2, T = 27.631000 C 22:13:30 Temperature Measurement, Probe Number = 3, T = 22.321000 C 22:13:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323098 V 22:13:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323098 (V, A, ohm, ...), Measured Value = 28.376367 (C, atm, Hz, ...) 22:13:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.343051 V 22:13:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343051 (V, A, ohm, ...), Measured Value = 28.653488 (C, atm, Hz, ...) 22:13:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264069 V 22:13:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264069 (V, A, ohm, ...), Measured Value = 94.805205 (C, atm, Hz, ...) 22:13:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092838 V 22:13:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092838 (V, A, ohm, ...), Measured Value = 6.962842 (C, atm, Hz, ...) 22:13:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 22:13:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880514 (C, atm, Hz, ...) 22:13:47 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.14 P3 = Right Coil Outgoing Side, Value = 27.92 P4 = Left Coil Middle, Value = 27.63 P5 = Ambient, Value = 22.32 P6 = Supply Temp(C), Value = 28.38 P7 = Return Temp(C), Value = 28.65 P8 = Supply Pres(psi), Value = 94.81 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.88 22:13:47 Magnet system MAIN current ramping to 125.0000 A... 22:15:11 Magnet Current for MAIN, Imag = 124.9901 A Vtrans = 1.249900 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:15:13 Main (V) Voltage Measurement, V = 4.456949 V 22:15:18 Temperature Measurement, Probe Number = 0, T = 26.140000 C 22:15:20 Temperature Measurement, Probe Number = 1, T = 27.701000 C 22:15:22 Temperature Measurement, Probe Number = 2, T = 27.536000 C 22:15:25 Temperature Measurement, Probe Number = 3, T = 22.268000 C 22:15:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322680 V 22:15:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322680 (V, A, ohm, ...), Measured Value = 28.370554 (C, atm, Hz, ...) 22:15:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340324 V 22:15:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340324 (V, A, ohm, ...), Measured Value = 28.615615 (C, atm, Hz, ...) 22:15:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259889 V 22:15:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259889 (V, A, ohm, ...), Measured Value = 94.491712 (C, atm, Hz, ...) 22:15:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093007 V 22:15:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093007 (V, A, ohm, ...), Measured Value = 6.975532 (C, atm, Hz, ...) 22:15:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 22:15:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885468 (C, atm, Hz, ...) 22:15:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.14 P3 = Right Coil Outgoing Side, Value = 27.70 P4 = Left Coil Middle, Value = 27.54 P5 = Ambient, Value = 22.27 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.62 P8 = Supply Pres(psi), Value = 94.49 P9 = Return Pres(psi), Value = 6.98 P10 = Flow Rate(gpm), Value = 0.89 22:15:41 Magnet system MAIN current ramping to 0.0000 A... 22:17:05 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:17:07 Main (V) Voltage Measurement, V = 0.000001 V 22:17:13 Temperature Measurement, Probe Number = 0, T = 26.142000 C 22:17:15 Temperature Measurement, Probe Number = 1, T = 27.924000 C 22:17:17 Temperature Measurement, Probe Number = 2, T = 27.643000 C 22:17:19 Temperature Measurement, Probe Number = 3, T = 22.289000 C 22:17:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323253 V 22:17:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323253 (V, A, ohm, ...), Measured Value = 28.378519 (C, atm, Hz, ...) 22:17:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.341625 V 22:17:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341625 (V, A, ohm, ...), Measured Value = 28.633681 (C, atm, Hz, ...) 22:17:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271799 V 22:17:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271799 (V, A, ohm, ...), Measured Value = 95.384917 (C, atm, Hz, ...) 22:17:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092953 V 22:17:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092953 (V, A, ohm, ...), Measured Value = 6.971468 (C, atm, Hz, ...) 22:17:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 22:17:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885454 (C, atm, Hz, ...) 22:17:35 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.14 P3 = Right Coil Outgoing Side, Value = 27.92 P4 = Left Coil Middle, Value = 27.64 P5 = Ambient, Value = 22.29 P6 = Supply Temp(C), Value = 28.38 P7 = Return Temp(C), Value = 28.63 P8 = Supply Pres(psi), Value = 95.38 P9 = Return Pres(psi), Value = 6.97 P10 = Flow Rate(gpm), Value = 0.89 22:17:35 Magnet system MAIN current ramping to 125.0000 A... 22:18:59 Magnet Current for MAIN, Imag = 124.9930 A Vtrans = 1.249929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:19:01 Main (V) Voltage Measurement, V = 4.456936 V 22:19:06 Temperature Measurement, Probe Number = 0, T = 26.147000 C 22:19:08 Temperature Measurement, Probe Number = 1, T = 27.715000 C 22:19:10 Temperature Measurement, Probe Number = 2, T = 27.576000 C 22:19:13 Temperature Measurement, Probe Number = 3, T = 22.277000 C 22:19:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322921 V 22:19:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322921 (V, A, ohm, ...), Measured Value = 28.373908 (C, atm, Hz, ...) 22:19:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.339932 V 22:19:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339932 (V, A, ohm, ...), Measured Value = 28.610161 (C, atm, Hz, ...) 22:19:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.268369 V 22:19:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.268369 (V, A, ohm, ...), Measured Value = 95.127705 (C, atm, Hz, ...) 22:19:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092702 V 22:19:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092702 (V, A, ohm, ...), Measured Value = 6.952673 (C, atm, Hz, ...) 22:19:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 22:19:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.883161 (C, atm, Hz, ...) 22:19:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.15 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.58 P5 = Ambient, Value = 22.28 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.61 P8 = Supply Pres(psi), Value = 95.13 P9 = Return Pres(psi), Value = 6.95 P10 = Flow Rate(gpm), Value = 0.88 22:19:29 Magnet system MAIN current ramping to 0.0000 A... 22:20:53 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:20:55 Main (V) Voltage Measurement, V = -0.000001 V 22:21:00 Temperature Measurement, Probe Number = 0, T = 26.110000 C 22:21:02 Temperature Measurement, Probe Number = 1, T = 27.933000 C 22:21:04 Temperature Measurement, Probe Number = 2, T = 27.742000 C 22:21:06 Temperature Measurement, Probe Number = 3, T = 22.321000 C 22:21:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322815 V 22:21:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322815 (V, A, ohm, ...), Measured Value = 28.372437 (C, atm, Hz, ...) 22:21:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.341323 V 22:21:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341323 (V, A, ohm, ...), Measured Value = 28.629483 (C, atm, Hz, ...) 22:21:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.256605 V 22:21:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.256605 (V, A, ohm, ...), Measured Value = 94.245352 (C, atm, Hz, ...) 22:21:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092786 V 22:21:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092786 (V, A, ohm, ...), Measured Value = 6.958972 (C, atm, Hz, ...) 22:21:23 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 22:21:23 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.886821 (C, atm, Hz, ...) 22:21:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.11 P3 = Right Coil Outgoing Side, Value = 27.93 P4 = Left Coil Middle, Value = 27.74 P5 = Ambient, Value = 22.32 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.63 P8 = Supply Pres(psi), Value = 94.25 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.89 22:21:23 Magnet system MAIN current ramping to 125.0000 A... 22:22:47 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:22:49 Main (V) Voltage Measurement, V = 4.456785 V 22:22:54 Temperature Measurement, Probe Number = 0, T = 26.086000 C 22:22:56 Temperature Measurement, Probe Number = 1, T = 27.712000 C 22:22:58 Temperature Measurement, Probe Number = 2, T = 27.630000 C 22:23:00 Temperature Measurement, Probe Number = 3, T = 22.313000 C 22:23:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322760 V 22:23:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322760 (V, A, ohm, ...), Measured Value = 28.371665 (C, atm, Hz, ...) 22:23:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.339730 V 22:23:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339730 (V, A, ohm, ...), Measured Value = 28.607363 (C, atm, Hz, ...) 22:23:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258967 V 22:23:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258967 (V, A, ohm, ...), Measured Value = 94.422540 (C, atm, Hz, ...) 22:23:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093073 V 22:23:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093073 (V, A, ohm, ...), Measured Value = 6.980475 (C, atm, Hz, ...) 22:23:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 22:23:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.880512 (C, atm, Hz, ...) 22:23:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.09 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.63 P5 = Ambient, Value = 22.31 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.61 P8 = Supply Pres(psi), Value = 94.42 P9 = Return Pres(psi), Value = 6.98 P10 = Flow Rate(gpm), Value = 0.88 22:23:17 Magnet system MAIN current ramping to 0.0000 A... 22:24:40 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:24:43 Main (V) Voltage Measurement, V = -0.000004 V 22:24:48 Temperature Measurement, Probe Number = 0, T = 26.104000 C 22:24:50 Temperature Measurement, Probe Number = 1, T = 27.901000 C 22:24:52 Temperature Measurement, Probe Number = 2, T = 27.678000 C 22:24:54 Temperature Measurement, Probe Number = 3, T = 22.285000 C 22:24:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323266 V 22:24:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323266 (V, A, ohm, ...), Measured Value = 28.378699 (C, atm, Hz, ...) 22:24:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340628 V 22:24:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340628 (V, A, ohm, ...), Measured Value = 28.619832 (C, atm, Hz, ...) 22:25:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264575 V 22:25:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264575 (V, A, ohm, ...), Measured Value = 94.843088 (C, atm, Hz, ...) 22:25:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092745 V 22:25:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092745 (V, A, ohm, ...), Measured Value = 6.955868 (C, atm, Hz, ...) 22:25:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 22:25:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880476 (C, atm, Hz, ...) 22:25:10 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.10 P3 = Right Coil Outgoing Side, Value = 27.90 P4 = Left Coil Middle, Value = 27.68 P5 = Ambient, Value = 22.29 P6 = Supply Temp(C), Value = 28.38 P7 = Return Temp(C), Value = 28.62 P8 = Supply Pres(psi), Value = 94.84 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.88 22:25:10 Magnet system MAIN current ramping to 75.0000 A... 22:26:06 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:26:08 Main (V) Voltage Measurement, V = 2.668961 V 22:26:14 Temperature Measurement, Probe Number = 0, T = 26.099000 C 22:26:16 Temperature Measurement, Probe Number = 1, T = 27.644000 C 22:26:18 Temperature Measurement, Probe Number = 2, T = 27.502000 C 22:26:20 Temperature Measurement, Probe Number = 3, T = 22.289000 C 22:26:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322923 V 22:26:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322923 (V, A, ohm, ...), Measured Value = 28.373926 (C, atm, Hz, ...) 22:26:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.342321 V 22:26:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.342321 (V, A, ohm, ...), Measured Value = 28.643351 (C, atm, Hz, ...) 22:26:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263748 V 22:26:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263748 (V, A, ohm, ...), Measured Value = 94.781085 (C, atm, Hz, ...) 22:26:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092855 V 22:26:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092855 (V, A, ohm, ...), Measured Value = 6.964102 (C, atm, Hz, ...) 22:26:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 22:26:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885340 (C, atm, Hz, ...) 22:26:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.10 P3 = Right Coil Outgoing Side, Value = 27.64 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 22.29 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.64 P8 = Supply Pres(psi), Value = 94.78 P9 = Return Pres(psi), Value = 6.96 P10 = Flow Rate(gpm), Value = 0.89 22:26:36 Magnetic Field Measurement Measuring the magnet strength... 22:26:36 Integrated Voltage Measurement... 22:26:38 Magnet Current for MAIN, Imag = 75.0206 A Vtrans = 0.750205 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:26:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405776 Vs 22:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014403092 Vs 22:27:00 Magnet Current for MAIN, Imag = 75.0204 A Vtrans = 0.750203 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:27:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408773 Vs 22:27:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014403332 Vs 22:27:21 Magnet Current for MAIN, Imag = 75.0212 A Vtrans = 0.750211 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:27:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406644 Vs 22:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400914 Vs 22:27:42 Magnet Current for MAIN, Imag = 75.0209 A Vtrans = 0.750208 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:27:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407925 Vs 22:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402779 Vs 22:28:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404904 +- 0.000000867 Vs 22:28:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014404904 +- 0.000000867 Vs BL = -0.16005449 +- 0.00000963 Tm 22:28:05 Position moved: 0.000000 m 22:28:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16005 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16005 0.00001 -0.16005 0.00000 22:28:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16005 0.00001 SL = -0.1600545 +- 0.0000096 Tm^2/m^n 22:28:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600545 +- 0.0000096 Tm^2/m^n 22:28:07 Position moved: 0.000000 m 22:28:07 Magnet system MAIN current ramping to 125.0000 A... 22:28:46 Magnet system MAIN current ramping to 0.0000 A... 22:30:09 Magnet system MAIN current ramping to 125.0000 A... 22:31:31 Magnet system MAIN current ramping to 0.0000 A... 22:32:53 Magnet system MAIN current ramping to 125.0000 A... 22:34:15 Magnet system MAIN current ramping to 0.0000 A... 22:35:39 Position moved: 0.000000 m 22:35:42 Magnet system MAIN current ramping to 87.5000 A... 22:36:44 Magnet Current for MAIN, Imag = 87.4672 A Vtrans = 0.874672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:36:46 Main (V) Voltage Measurement, V = 3.113248 V 22:36:51 Temperature Measurement, Probe Number = 0, T = 26.093000 C 22:36:53 Temperature Measurement, Probe Number = 1, T = 27.643000 C 22:36:55 Temperature Measurement, Probe Number = 2, T = 27.415000 C 22:36:57 Temperature Measurement, Probe Number = 3, T = 22.221000 C 22:37:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322722 V 22:37:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322722 (V, A, ohm, ...), Measured Value = 28.371146 (C, atm, Hz, ...) 22:37:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.335145 V 22:37:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335145 (V, A, ohm, ...), Measured Value = 28.543675 (C, atm, Hz, ...) 22:37:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.262142 V 22:37:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.262142 (V, A, ohm, ...), Measured Value = 94.660665 (C, atm, Hz, ...) 22:37:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093152 V 22:37:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093152 (V, A, ohm, ...), Measured Value = 6.986385 (C, atm, Hz, ...) 22:37:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 22:37:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.873248 (C, atm, Hz, ...) 22:37:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.09 P3 = Right Coil Outgoing Side, Value = 27.64 P4 = Left Coil Middle, Value = 27.41 P5 = Ambient, Value = 22.22 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.54 P8 = Supply Pres(psi), Value = 94.66 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.87 22:37:14 Magnetic Field Measurement Measuring the magnet strength... 22:37:14 Integrated Voltage Measurement... 22:37:16 Magnet Current for MAIN, Imag = 87.4676 A Vtrans = 0.874675 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:37:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782355 Vs 22:37:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776570 Vs 22:37:38 Magnet Current for MAIN, Imag = 87.4672 A Vtrans = 0.874672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:37:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782194 Vs 22:37:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774557 Vs 22:37:59 Magnet Current for MAIN, Imag = 87.4674 A Vtrans = 0.874673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:38:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782068 Vs 22:38:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776759 Vs 22:38:20 Magnet Current for MAIN, Imag = 87.4675 A Vtrans = 0.874674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:38:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781934 Vs 22:38:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776915 Vs 22:38:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779169 +- 0.000000459 Vs 22:38:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016779169 +- 0.000000459 Vs BL = -0.18643521 +- 0.00000510 Tm 22:38:42 Position moved: 0.000000 m 22:38:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18644 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18644 0.00001 -0.18644 0.00000 22:38:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18644 0.00001 SL = -0.1864352 +- 0.0000051 Tm^2/m^n 22:38:42 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864352 +- 0.0000051 Tm^2/m^n 22:38:45 Position moved: 0.000000 m 22:38:45 Magnet system MAIN current ramping to 75.0000 A... 22:39:05 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:39:07 Main (V) Voltage Measurement, V = 2.672069 V 22:39:12 Temperature Measurement, Probe Number = 0, T = 26.085000 C 22:39:14 Temperature Measurement, Probe Number = 1, T = 27.673000 C 22:39:16 Temperature Measurement, Probe Number = 2, T = 27.539000 C 22:39:18 Temperature Measurement, Probe Number = 3, T = 22.220000 C 22:39:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321949 V 22:39:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321949 (V, A, ohm, ...), Measured Value = 28.360400 (C, atm, Hz, ...) 22:39:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328494 V 22:39:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328494 (V, A, ohm, ...), Measured Value = 28.451301 (C, atm, Hz, ...) 22:39:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265607 V 22:39:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265607 (V, A, ohm, ...), Measured Value = 94.920488 (C, atm, Hz, ...) 22:39:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092961 V 22:39:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092961 (V, A, ohm, ...), Measured Value = 6.972045 (C, atm, Hz, ...) 22:39:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 22:39:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.889741 (C, atm, Hz, ...) 22:39:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.09 P3 = Right Coil Outgoing Side, Value = 27.67 P4 = Left Coil Middle, Value = 27.54 P5 = Ambient, Value = 22.22 P6 = Supply Temp(C), Value = 28.36 P7 = Return Temp(C), Value = 28.45 P8 = Supply Pres(psi), Value = 94.92 P9 = Return Pres(psi), Value = 6.97 P10 = Flow Rate(gpm), Value = 0.89 22:39:35 Magnet system MAIN current ramping to 125.0000 A... 22:40:16 Magnet Current for MAIN, Imag = 124.9899 A Vtrans = 1.249898 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:40:18 Main (V) Voltage Measurement, V = 4.456108 V 22:40:24 Temperature Measurement, Probe Number = 0, T = 26.086000 C 22:40:26 Temperature Measurement, Probe Number = 1, T = 27.727000 C 22:40:28 Temperature Measurement, Probe Number = 2, T = 27.565000 C 22:40:30 Temperature Measurement, Probe Number = 3, T = 22.182000 C 22:40:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321805 V 22:40:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321805 (V, A, ohm, ...), Measured Value = 28.358408 (C, atm, Hz, ...) 22:40:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331262 V 22:40:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331262 (V, A, ohm, ...), Measured Value = 28.489747 (C, atm, Hz, ...) 22:40:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259111 V 22:40:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259111 (V, A, ohm, ...), Measured Value = 94.433295 (C, atm, Hz, ...) 22:40:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092950 V 22:40:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092950 (V, A, ohm, ...), Measured Value = 6.971273 (C, atm, Hz, ...) 22:40:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 22:40:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.883430 (C, atm, Hz, ...) 22:40:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.09 P3 = Right Coil Outgoing Side, Value = 27.73 P4 = Left Coil Middle, Value = 27.57 P5 = Ambient, Value = 22.18 P6 = Supply Temp(C), Value = 28.36 P7 = Return Temp(C), Value = 28.49 P8 = Supply Pres(psi), Value = 94.43 P9 = Return Pres(psi), Value = 6.97 P10 = Flow Rate(gpm), Value = 0.88 22:40:46 Magnet system MAIN current ramping to 0.0000 A... 22:42:10 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:42:12 Main (V) Voltage Measurement, V = -0.000003 V 22:42:17 Temperature Measurement, Probe Number = 0, T = 26.077000 C 22:42:19 Temperature Measurement, Probe Number = 1, T = 27.871000 C 22:42:21 Temperature Measurement, Probe Number = 2, T = 27.570000 C 22:42:23 Temperature Measurement, Probe Number = 3, T = 22.230000 C 22:42:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322700 V 22:42:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322700 (V, A, ohm, ...), Measured Value = 28.370840 (C, atm, Hz, ...) 22:42:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.341150 V 22:42:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341150 (V, A, ohm, ...), Measured Value = 28.627079 (C, atm, Hz, ...) 22:42:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266702 V 22:42:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266702 (V, A, ohm, ...), Measured Value = 95.002643 (C, atm, Hz, ...) 22:42:32 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093320 V 22:42:32 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093320 (V, A, ohm, ...), Measured Value = 6.998977 (C, atm, Hz, ...) 22:42:40 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 22:42:40 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890950 (C, atm, Hz, ...) 22:42:40 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.08 P3 = Right Coil Outgoing Side, Value = 27.87 P4 = Left Coil Middle, Value = 27.57 P5 = Ambient, Value = 22.23 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.63 P8 = Supply Pres(psi), Value = 95.00 P9 = Return Pres(psi), Value = 7.00 P10 = Flow Rate(gpm), Value = 0.89 22:42:40 Magnet system MAIN current ramping to 125.0000 A... 22:44:05 Magnet Current for MAIN, Imag = 124.9911 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:44:07 Main (V) Voltage Measurement, V = 4.457085 V 22:44:12 Temperature Measurement, Probe Number = 0, T = 26.073000 C 22:44:14 Temperature Measurement, Probe Number = 1, T = 27.650000 C 22:44:16 Temperature Measurement, Probe Number = 2, T = 27.500000 C 22:44:18 Temperature Measurement, Probe Number = 3, T = 22.236000 C 22:44:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322649 V 22:44:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322649 (V, A, ohm, ...), Measured Value = 28.370124 (C, atm, Hz, ...) 22:44:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338052 V 22:44:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338052 (V, A, ohm, ...), Measured Value = 28.584058 (C, atm, Hz, ...) 22:44:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266912 V 22:44:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266912 (V, A, ohm, ...), Measured Value = 95.018430 (C, atm, Hz, ...) 22:44:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093203 V 22:44:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093203 (V, A, ohm, ...), Measured Value = 6.990263 (C, atm, Hz, ...) 22:44:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 22:44:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890026 (C, atm, Hz, ...) 22:44:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.07 P3 = Right Coil Outgoing Side, Value = 27.65 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 22.24 P6 = Supply Temp(C), Value = 28.37 P7 = Return Temp(C), Value = 28.58 P8 = Supply Pres(psi), Value = 95.02 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.89 22:44:35 Magnet system MAIN current ramping to 0.0000 A... 22:45:59 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:46:01 Main (V) Voltage Measurement, V = 0.000000 V 22:46:06 Temperature Measurement, Probe Number = 0, T = 26.067000 C 22:46:08 Temperature Measurement, Probe Number = 1, T = 27.866000 C 22:46:10 Temperature Measurement, Probe Number = 2, T = 27.573000 C 22:46:12 Temperature Measurement, Probe Number = 3, T = 22.283000 C 22:46:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322186 V 22:46:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322186 (V, A, ohm, ...), Measured Value = 28.363700 (C, atm, Hz, ...) 22:46:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.339492 V 22:46:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.339492 (V, A, ohm, ...), Measured Value = 28.604063 (C, atm, Hz, ...) 22:46:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266553 V 22:46:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266553 (V, A, ohm, ...), Measured Value = 94.991497 (C, atm, Hz, ...) 22:46:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093343 V 22:46:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093343 (V, A, ohm, ...), Measured Value = 7.000725 (C, atm, Hz, ...) 22:46:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 22:46:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888095 (C, atm, Hz, ...) 22:46:29 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.07 P3 = Right Coil Outgoing Side, Value = 27.87 P4 = Left Coil Middle, Value = 27.57 P5 = Ambient, Value = 22.28 P6 = Supply Temp(C), Value = 28.36 P7 = Return Temp(C), Value = 28.60 P8 = Supply Pres(psi), Value = 94.99 P9 = Return Pres(psi), Value = 7.00 P10 = Flow Rate(gpm), Value = 0.89 22:46:29 Magnet system MAIN current ramping to 125.0000 A... 22:47:52 Magnet Current for MAIN, Imag = 124.9902 A Vtrans = 1.249901 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:47:54 Main (V) Voltage Measurement, V = 4.456522 V 22:47:59 Temperature Measurement, Probe Number = 0, T = 26.066000 C 22:48:01 Temperature Measurement, Probe Number = 1, T = 27.621000 C 22:48:03 Temperature Measurement, Probe Number = 2, T = 27.434000 C 22:48:05 Temperature Measurement, Probe Number = 3, T = 22.249000 C 22:48:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322028 V 22:48:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322028 (V, A, ohm, ...), Measured Value = 28.361494 (C, atm, Hz, ...) 22:48:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338127 V 22:48:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338127 (V, A, ohm, ...), Measured Value = 28.585100 (C, atm, Hz, ...) 22:48:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.254982 V 22:48:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.254982 (V, A, ohm, ...), Measured Value = 94.123680 (C, atm, Hz, ...) 22:48:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093229 V 22:48:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093229 (V, A, ohm, ...), Measured Value = 6.992197 (C, atm, Hz, ...) 22:48:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 22:48:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895352 (C, atm, Hz, ...) 22:48:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.07 P3 = Right Coil Outgoing Side, Value = 27.62 P4 = Left Coil Middle, Value = 27.43 P5 = Ambient, Value = 22.25 P6 = Supply Temp(C), Value = 28.36 P7 = Return Temp(C), Value = 28.59 P8 = Supply Pres(psi), Value = 94.12 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.90 22:48:22 Magnet system MAIN current ramping to 0.0000 A... 22:49:46 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:49:48 Main (V) Voltage Measurement, V = -0.000004 V 22:49:53 Temperature Measurement, Probe Number = 0, T = 26.083000 C 22:49:55 Temperature Measurement, Probe Number = 1, T = 27.845000 C 22:49:57 Temperature Measurement, Probe Number = 2, T = 27.565000 C 22:49:59 Temperature Measurement, Probe Number = 3, T = 22.201000 C 22:50:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321643 V 22:50:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321643 (V, A, ohm, ...), Measured Value = 28.356147 (C, atm, Hz, ...) 22:50:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.338575 V 22:50:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338575 (V, A, ohm, ...), Measured Value = 28.591325 (C, atm, Hz, ...) 22:50:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258055 V 22:50:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258055 (V, A, ohm, ...), Measured Value = 94.354148 (C, atm, Hz, ...) 22:50:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093259 V 22:50:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093259 (V, A, ohm, ...), Measured Value = 6.994425 (C, atm, Hz, ...) 22:50:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 22:50:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880442 (C, atm, Hz, ...) 22:50:16 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.08 P3 = Right Coil Outgoing Side, Value = 27.84 P4 = Left Coil Middle, Value = 27.57 P5 = Ambient, Value = 22.20 P6 = Supply Temp(C), Value = 28.36 P7 = Return Temp(C), Value = 28.59 P8 = Supply Pres(psi), Value = 94.35 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.88 22:50:16 Magnet system MAIN current ramping to 125.0000 A... 22:51:40 Magnet Current for MAIN, Imag = 124.9903 A Vtrans = 1.249902 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:51:42 Main (V) Voltage Measurement, V = 4.456580 V 22:51:47 Temperature Measurement, Probe Number = 0, T = 26.075000 C 22:51:49 Temperature Measurement, Probe Number = 1, T = 27.628000 C 22:51:51 Temperature Measurement, Probe Number = 2, T = 27.459000 C 22:51:53 Temperature Measurement, Probe Number = 3, T = 22.203000 C 22:51:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321170 V 22:51:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321170 (V, A, ohm, ...), Measured Value = 28.349582 (C, atm, Hz, ...) 22:51:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.336345 V 22:51:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336345 (V, A, ohm, ...), Measured Value = 28.560342 (C, atm, Hz, ...) 22:52:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266105 V 22:52:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266105 (V, A, ohm, ...), Measured Value = 94.957882 (C, atm, Hz, ...) 22:52:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093302 V 22:52:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093302 (V, A, ohm, ...), Measured Value = 6.997620 (C, atm, Hz, ...) 22:52:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 22:52:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.885715 (C, atm, Hz, ...) 22:52:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.07 P3 = Right Coil Outgoing Side, Value = 27.63 P4 = Left Coil Middle, Value = 27.46 P5 = Ambient, Value = 22.20 P6 = Supply Temp(C), Value = 28.35 P7 = Return Temp(C), Value = 28.56 P8 = Supply Pres(psi), Value = 94.96 P9 = Return Pres(psi), Value = 7.00 P10 = Flow Rate(gpm), Value = 0.89 22:52:10 Magnet system MAIN current ramping to 0.0000 A... 22:53:33 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:53:35 Main (V) Voltage Measurement, V = 0.000003 V 22:53:41 Temperature Measurement, Probe Number = 0, T = 26.078000 C 22:53:43 Temperature Measurement, Probe Number = 1, T = 27.842000 C 22:53:45 Temperature Measurement, Probe Number = 2, T = 27.546000 C 22:53:47 Temperature Measurement, Probe Number = 3, T = 22.169000 C 22:53:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320567 V 22:53:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320567 (V, A, ohm, ...), Measured Value = 28.341204 (C, atm, Hz, ...) 22:53:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.337791 V 22:53:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337791 (V, A, ohm, ...), Measured Value = 28.580435 (C, atm, Hz, ...) 22:53:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.260796 V 22:53:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.260796 (V, A, ohm, ...), Measured Value = 94.559722 (C, atm, Hz, ...) 22:53:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093156 V 22:53:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093156 (V, A, ohm, ...), Measured Value = 6.986678 (C, atm, Hz, ...) 22:54:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 22:54:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.872506 (C, atm, Hz, ...) 22:54:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.08 P3 = Right Coil Outgoing Side, Value = 27.84 P4 = Left Coil Middle, Value = 27.55 P5 = Ambient, Value = 22.17 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.58 P8 = Supply Pres(psi), Value = 94.56 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.87 22:54:03 Magnet system MAIN current ramping to 75.0000 A... 22:54:59 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:55:01 Main (V) Voltage Measurement, V = 2.668839 V 22:55:06 Temperature Measurement, Probe Number = 0, T = 26.064000 C 22:55:08 Temperature Measurement, Probe Number = 1, T = 27.591000 C 22:55:11 Temperature Measurement, Probe Number = 2, T = 27.412000 C 22:55:13 Temperature Measurement, Probe Number = 3, T = 22.204000 C 22:55:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320620 V 22:55:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320620 (V, A, ohm, ...), Measured Value = 28.341939 (C, atm, Hz, ...) 22:55:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.340036 V 22:55:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.340036 (V, A, ohm, ...), Measured Value = 28.611615 (C, atm, Hz, ...) 22:55:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258494 V 22:55:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258494 (V, A, ohm, ...), Measured Value = 94.387087 (C, atm, Hz, ...) 22:55:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093202 V 22:55:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093202 (V, A, ohm, ...), Measured Value = 6.990165 (C, atm, Hz, ...) 22:55:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 22:55:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877956 (C, atm, Hz, ...) 22:55:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.06 P3 = Right Coil Outgoing Side, Value = 27.59 P4 = Left Coil Middle, Value = 27.41 P5 = Ambient, Value = 22.20 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.61 P8 = Supply Pres(psi), Value = 94.39 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.88 22:55:29 Magnetic Field Measurement Measuring the magnet strength... 22:55:29 Integrated Voltage Measurement... 22:55:31 Magnet Current for MAIN, Imag = 75.0208 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:55:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405792 Vs 22:55:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402090 Vs 22:55:53 Magnet Current for MAIN, Imag = 75.0208 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:56:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408330 Vs 22:56:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014404310 Vs 22:56:14 Magnet Current for MAIN, Imag = 75.0208 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:56:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405564 Vs 22:56:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014403278 Vs 22:56:35 Magnet Current for MAIN, Imag = 75.0210 A Vtrans = 0.750209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 22:56:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405512 Vs 22:56:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014403953 Vs 22:56:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404854 +- 0.000000892 Vs 22:56:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014404854 +- 0.000000892 Vs BL = -0.16005393 +- 0.00000992 Tm 22:56:58 Position moved: 0.000000 m 22:56:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16005 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16005 0.00001 -0.16005 0.00000 22:56:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16005 0.00001 SL = -0.1600539 +- 0.0000099 Tm^2/m^n 22:56:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600539 +- 0.0000099 Tm^2/m^n 22:57:00 Position moved: 0.000000 m 22:57:00 Magnet system MAIN current ramping to 125.0000 A... 22:57:40 Magnet system MAIN current ramping to 0.0000 A... 22:59:01 Magnet system MAIN current ramping to 125.0000 A... 23:00:22 Magnet system MAIN current ramping to 0.0000 A... 23:01:45 Magnet system MAIN current ramping to 125.0000 A... 23:03:07 Magnet system MAIN current ramping to 0.0000 A... 23:04:31 Position moved: 0.000000 m 23:04:34 Magnet system MAIN current ramping to 87.5000 A... 23:05:37 Magnet Current for MAIN, Imag = 87.4672 A Vtrans = 0.874672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:05:39 Main (V) Voltage Measurement, V = 3.112887 V 23:05:44 Temperature Measurement, Probe Number = 0, T = 26.028000 C 23:05:46 Temperature Measurement, Probe Number = 1, T = 27.540000 C 23:05:48 Temperature Measurement, Probe Number = 2, T = 27.321000 C 23:05:50 Temperature Measurement, Probe Number = 3, T = 22.268000 C 23:05:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320015 V 23:05:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320015 (V, A, ohm, ...), Measured Value = 28.333543 (C, atm, Hz, ...) 23:05:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331651 V 23:05:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331651 (V, A, ohm, ...), Measured Value = 28.495147 (C, atm, Hz, ...) 23:05:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.257316 V 23:05:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.257316 (V, A, ohm, ...), Measured Value = 94.298738 (C, atm, Hz, ...) 23:05:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093426 V 23:05:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093426 (V, A, ohm, ...), Measured Value = 7.006920 (C, atm, Hz, ...) 23:06:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 23:06:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885456 (C, atm, Hz, ...) 23:06:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 26.03 P3 = Right Coil Outgoing Side, Value = 27.54 P4 = Left Coil Middle, Value = 27.32 P5 = Ambient, Value = 22.27 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.50 P8 = Supply Pres(psi), Value = 94.30 P9 = Return Pres(psi), Value = 7.01 P10 = Flow Rate(gpm), Value = 0.89 23:06:07 Magnetic Field Measurement Measuring the magnet strength... 23:06:07 Integrated Voltage Measurement... 23:06:09 Magnet Current for MAIN, Imag = 87.4675 A Vtrans = 0.874674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:06:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778965 Vs 23:06:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777053 Vs 23:06:31 Magnet Current for MAIN, Imag = 87.4674 A Vtrans = 0.874673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:06:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016783930 Vs 23:06:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016779974 Vs 23:06:51 Magnet Current for MAIN, Imag = 87.4674 A Vtrans = 0.874673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:07:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777386 Vs 23:07:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775120 Vs 23:07:12 Magnet Current for MAIN, Imag = 87.4667 A Vtrans = 0.874666 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:07:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779054 Vs 23:07:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776664 Vs 23:07:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778518 +- 0.000002099 Vs 23:07:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016778518 +- 0.000002099 Vs BL = -0.18642798 +- 0.00002332 Tm 23:07:34 Position moved: 0.000000 m 23:07:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18643 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18643 0.00002 -0.18643 0.00000 23:07:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18643 0.00002 SL = -0.1864280 +- 0.0000233 Tm^2/m^n 23:07:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864280 +- 0.0000233 Tm^2/m^n 23:07:37 Position moved: 0.000000 m 23:07:37 Magnet system MAIN current ramping to 75.0000 A... 23:07:57 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:07:59 Main (V) Voltage Measurement, V = 2.671730 V 23:08:05 Temperature Measurement, Probe Number = 0, T = 26.029000 C 23:08:07 Temperature Measurement, Probe Number = 1, T = 27.619000 C 23:08:09 Temperature Measurement, Probe Number = 2, T = 27.477000 C 23:08:11 Temperature Measurement, Probe Number = 3, T = 22.215000 C 23:08:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319444 V 23:08:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319444 (V, A, ohm, ...), Measured Value = 28.325614 (C, atm, Hz, ...) 23:08:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.324904 V 23:08:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324904 (V, A, ohm, ...), Measured Value = 28.401446 (C, atm, Hz, ...) 23:08:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259121 V 23:08:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259121 (V, A, ohm, ...), Measured Value = 94.434068 (C, atm, Hz, ...) 23:08:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.092985 V 23:08:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.092985 (V, A, ohm, ...), Measured Value = 6.973890 (C, atm, Hz, ...) 23:08:27 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 23:08:27 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.889303 (C, atm, Hz, ...) 23:08:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.03 P3 = Right Coil Outgoing Side, Value = 27.62 P4 = Left Coil Middle, Value = 27.48 P5 = Ambient, Value = 22.21 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.40 P8 = Supply Pres(psi), Value = 94.43 P9 = Return Pres(psi), Value = 6.97 P10 = Flow Rate(gpm), Value = 0.89 23:08:27 Magnet system MAIN current ramping to 125.0000 A... 23:09:09 Magnet Current for MAIN, Imag = 124.9895 A Vtrans = 1.249894 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:09:11 Main (V) Voltage Measurement, V = 4.455097 V 23:09:16 Temperature Measurement, Probe Number = 0, T = 26.023000 C 23:09:18 Temperature Measurement, Probe Number = 1, T = 27.662000 C 23:09:20 Temperature Measurement, Probe Number = 2, T = 27.467000 C 23:09:22 Temperature Measurement, Probe Number = 3, T = 22.127000 C 23:09:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320221 V 23:09:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320221 (V, A, ohm, ...), Measured Value = 28.336396 (C, atm, Hz, ...) 23:09:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.327502 V 23:09:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327502 (V, A, ohm, ...), Measured Value = 28.437524 (C, atm, Hz, ...) 23:09:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264378 V 23:09:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264378 (V, A, ohm, ...), Measured Value = 94.828358 (C, atm, Hz, ...) 23:09:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093255 V 23:09:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093255 (V, A, ohm, ...), Measured Value = 6.994132 (C, atm, Hz, ...) 23:09:39 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 23:09:39 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.872523 (C, atm, Hz, ...) 23:09:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.02 P3 = Right Coil Outgoing Side, Value = 27.66 P4 = Left Coil Middle, Value = 27.47 P5 = Ambient, Value = 22.13 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.44 P8 = Supply Pres(psi), Value = 94.83 P9 = Return Pres(psi), Value = 6.99 P10 = Flow Rate(gpm), Value = 0.87 23:09:39 Magnet system MAIN current ramping to 0.0000 A... 23:11:02 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:11:04 Main (V) Voltage Measurement, V = -0.000004 V 23:11:09 Temperature Measurement, Probe Number = 0, T = 26.025000 C 23:11:11 Temperature Measurement, Probe Number = 1, T = 27.815000 C 23:11:13 Temperature Measurement, Probe Number = 2, T = 27.574000 C 23:11:15 Temperature Measurement, Probe Number = 3, T = 22.085000 C 23:11:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320186 V 23:11:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320186 (V, A, ohm, ...), Measured Value = 28.335911 (C, atm, Hz, ...) 23:11:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.336954 V 23:11:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336954 (V, A, ohm, ...), Measured Value = 28.568810 (C, atm, Hz, ...) 23:11:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.260512 V 23:11:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.260512 (V, A, ohm, ...), Measured Value = 94.538408 (C, atm, Hz, ...) 23:11:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093490 V 23:11:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093490 (V, A, ohm, ...), Measured Value = 7.011765 (C, atm, Hz, ...) 23:11:32 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 23:11:32 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885427 (C, atm, Hz, ...) 23:11:32 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.02 P3 = Right Coil Outgoing Side, Value = 27.82 P4 = Left Coil Middle, Value = 27.57 P5 = Ambient, Value = 22.09 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.57 P8 = Supply Pres(psi), Value = 94.54 P9 = Return Pres(psi), Value = 7.01 P10 = Flow Rate(gpm), Value = 0.89 23:11:32 Magnet system MAIN current ramping to 125.0000 A... 23:12:56 Magnet Current for MAIN, Imag = 124.9902 A Vtrans = 1.249901 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:12:58 Main (V) Voltage Measurement, V = 4.456332 V 23:13:03 Temperature Measurement, Probe Number = 0, T = 26.035000 C 23:13:05 Temperature Measurement, Probe Number = 1, T = 27.597000 C 23:13:08 Temperature Measurement, Probe Number = 2, T = 27.447000 C 23:13:10 Temperature Measurement, Probe Number = 3, T = 22.133000 C 23:13:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320384 V 23:13:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320384 (V, A, ohm, ...), Measured Value = 28.338674 (C, atm, Hz, ...) 23:13:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.334575 V 23:13:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334575 (V, A, ohm, ...), Measured Value = 28.535764 (C, atm, Hz, ...) 23:13:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265064 V 23:13:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265064 (V, A, ohm, ...), Measured Value = 94.879800 (C, atm, Hz, ...) 23:13:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093392 V 23:13:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093392 (V, A, ohm, ...), Measured Value = 7.004407 (C, atm, Hz, ...) 23:13:26 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 23:13:26 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890444 (C, atm, Hz, ...) 23:13:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.04 P3 = Right Coil Outgoing Side, Value = 27.60 P4 = Left Coil Middle, Value = 27.45 P5 = Ambient, Value = 22.13 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.54 P8 = Supply Pres(psi), Value = 94.88 P9 = Return Pres(psi), Value = 7.00 P10 = Flow Rate(gpm), Value = 0.89 23:13:26 Magnet system MAIN current ramping to 0.0000 A... 23:14:50 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:14:52 Main (V) Voltage Measurement, V = -0.000001 V 23:14:57 Temperature Measurement, Probe Number = 0, T = 26.014000 C 23:14:59 Temperature Measurement, Probe Number = 1, T = 27.805000 C 23:15:01 Temperature Measurement, Probe Number = 2, T = 27.526000 C 23:15:03 Temperature Measurement, Probe Number = 3, T = 22.058000 C 23:15:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320126 V 23:15:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320126 (V, A, ohm, ...), Measured Value = 28.335086 (C, atm, Hz, ...) 23:15:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.335623 V 23:15:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335623 (V, A, ohm, ...), Measured Value = 28.550314 (C, atm, Hz, ...) 23:15:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270480 V 23:15:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270480 (V, A, ohm, ...), Measured Value = 95.286007 (C, atm, Hz, ...) 23:15:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093383 V 23:15:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093383 (V, A, ohm, ...), Measured Value = 7.003725 (C, atm, Hz, ...) 23:15:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 23:15:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.887324 (C, atm, Hz, ...) 23:15:20 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.01 P3 = Right Coil Outgoing Side, Value = 27.80 P4 = Left Coil Middle, Value = 27.53 P5 = Ambient, Value = 22.06 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.55 P8 = Supply Pres(psi), Value = 95.29 P9 = Return Pres(psi), Value = 7.00 P10 = Flow Rate(gpm), Value = 0.89 23:15:20 Magnet system MAIN current ramping to 125.0000 A... 23:16:43 Magnet Current for MAIN, Imag = 124.9894 A Vtrans = 1.249893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:16:46 Main (V) Voltage Measurement, V = 4.456115 V 23:16:51 Temperature Measurement, Probe Number = 0, T = 25.998000 C 23:16:53 Temperature Measurement, Probe Number = 1, T = 27.593000 C 23:16:55 Temperature Measurement, Probe Number = 2, T = 27.443000 C 23:16:57 Temperature Measurement, Probe Number = 3, T = 22.077000 C 23:16:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319570 V 23:16:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319570 (V, A, ohm, ...), Measured Value = 28.327354 (C, atm, Hz, ...) 23:17:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.334286 V 23:17:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334286 (V, A, ohm, ...), Measured Value = 28.531746 (C, atm, Hz, ...) 23:17:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264950 V 23:17:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264950 (V, A, ohm, ...), Measured Value = 94.871273 (C, atm, Hz, ...) 23:17:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093446 V 23:17:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093446 (V, A, ohm, ...), Measured Value = 7.008473 (C, atm, Hz, ...) 23:17:13 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000883 V 23:17:13 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000883 (V, A, ohm, ...), Measured Value = 0.882858 (C, atm, Hz, ...) 23:17:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.00 P3 = Right Coil Outgoing Side, Value = 27.59 P4 = Left Coil Middle, Value = 27.44 P5 = Ambient, Value = 22.08 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.53 P8 = Supply Pres(psi), Value = 94.87 P9 = Return Pres(psi), Value = 7.01 P10 = Flow Rate(gpm), Value = 0.88 23:17:13 Magnet system MAIN current ramping to 0.0000 A... 23:18:37 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:18:39 Main (V) Voltage Measurement, V = 0.000001 V 23:18:44 Temperature Measurement, Probe Number = 0, T = 25.993000 C 23:18:46 Temperature Measurement, Probe Number = 1, T = 27.797000 C 23:18:48 Temperature Measurement, Probe Number = 2, T = 27.505000 C 23:18:50 Temperature Measurement, Probe Number = 3, T = 22.164000 C 23:18:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320251 V 23:18:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320251 (V, A, ohm, ...), Measured Value = 28.336826 (C, atm, Hz, ...) 23:18:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.334966 V 23:18:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334966 (V, A, ohm, ...), Measured Value = 28.541200 (C, atm, Hz, ...) 23:18:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258443 V 23:18:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258443 (V, A, ohm, ...), Measured Value = 94.383210 (C, atm, Hz, ...) 23:18:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093522 V 23:18:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093522 (V, A, ohm, ...), Measured Value = 7.014187 (C, atm, Hz, ...) 23:19:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 23:19:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890456 (C, atm, Hz, ...) 23:19:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.99 P3 = Right Coil Outgoing Side, Value = 27.80 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 22.16 P6 = Supply Temp(C), Value = 28.34 P7 = Return Temp(C), Value = 28.54 P8 = Supply Pres(psi), Value = 94.38 P9 = Return Pres(psi), Value = 7.01 P10 = Flow Rate(gpm), Value = 0.89 23:19:07 Magnet system MAIN current ramping to 125.0000 A... 23:20:31 Magnet Current for MAIN, Imag = 124.9895 A Vtrans = 1.249894 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:20:33 Main (V) Voltage Measurement, V = 4.456497 V 23:20:38 Temperature Measurement, Probe Number = 0, T = 25.984000 C 23:20:40 Temperature Measurement, Probe Number = 1, T = 27.580000 C 23:20:42 Temperature Measurement, Probe Number = 2, T = 27.391000 C 23:20:44 Temperature Measurement, Probe Number = 3, T = 22.124000 C 23:20:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319553 V 23:20:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319553 (V, A, ohm, ...), Measured Value = 28.327121 (C, atm, Hz, ...) 23:20:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333672 V 23:20:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333672 (V, A, ohm, ...), Measured Value = 28.523224 (C, atm, Hz, ...) 23:20:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258245 V 23:20:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258245 (V, A, ohm, ...), Measured Value = 94.368390 (C, atm, Hz, ...) 23:20:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093550 V 23:20:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093550 (V, A, ohm, ...), Measured Value = 7.016220 (C, atm, Hz, ...) 23:21:01 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 23:21:01 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890438 (C, atm, Hz, ...) 23:21:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.98 P3 = Right Coil Outgoing Side, Value = 27.58 P4 = Left Coil Middle, Value = 27.39 P5 = Ambient, Value = 22.12 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.52 P8 = Supply Pres(psi), Value = 94.37 P9 = Return Pres(psi), Value = 7.02 P10 = Flow Rate(gpm), Value = 0.89 23:21:01 Magnet system MAIN current ramping to 0.0000 A... 23:22:25 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:22:27 Main (V) Voltage Measurement, V = -0.000001 V 23:22:32 Temperature Measurement, Probe Number = 0, T = 25.979000 C 23:22:34 Temperature Measurement, Probe Number = 1, T = 27.778000 C 23:22:36 Temperature Measurement, Probe Number = 2, T = 27.500000 C 23:22:39 Temperature Measurement, Probe Number = 3, T = 22.155000 C 23:22:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319370 V 23:22:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319370 (V, A, ohm, ...), Measured Value = 28.324590 (C, atm, Hz, ...) 23:22:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.335102 V 23:22:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335102 (V, A, ohm, ...), Measured Value = 28.543083 (C, atm, Hz, ...) 23:22:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263159 V 23:22:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263159 (V, A, ohm, ...), Measured Value = 94.736910 (C, atm, Hz, ...) 23:22:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093484 V 23:22:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093484 (V, A, ohm, ...), Measured Value = 7.011285 (C, atm, Hz, ...) 23:22:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 23:22:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.889174 (C, atm, Hz, ...) 23:22:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.98 P3 = Right Coil Outgoing Side, Value = 27.78 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 22.16 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.54 P8 = Supply Pres(psi), Value = 94.74 P9 = Return Pres(psi), Value = 7.01 P10 = Flow Rate(gpm), Value = 0.89 23:22:55 Magnet system MAIN current ramping to 75.0000 A... 23:23:51 Magnet Current for MAIN, Imag = 75.0202 A Vtrans = 0.750201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:23:53 Main (V) Voltage Measurement, V = 2.668407 V 23:23:58 Temperature Measurement, Probe Number = 0, T = 25.980000 C 23:24:00 Temperature Measurement, Probe Number = 1, T = 27.526000 C 23:24:02 Temperature Measurement, Probe Number = 2, T = 27.301000 C 23:24:04 Temperature Measurement, Probe Number = 3, T = 22.148000 C 23:24:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319093 V 23:24:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319093 (V, A, ohm, ...), Measured Value = 28.320733 (C, atm, Hz, ...) 23:24:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.336857 V 23:24:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336857 (V, A, ohm, ...), Measured Value = 28.567464 (C, atm, Hz, ...) 23:24:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.262795 V 23:24:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.262795 (V, A, ohm, ...), Measured Value = 94.709587 (C, atm, Hz, ...) 23:24:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093556 V 23:24:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093556 (V, A, ohm, ...), Measured Value = 7.016708 (C, atm, Hz, ...) 23:24:21 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000871 V 23:24:21 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000871 (V, A, ohm, ...), Measured Value = 0.871411 (C, atm, Hz, ...) 23:24:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.98 P3 = Right Coil Outgoing Side, Value = 27.53 P4 = Left Coil Middle, Value = 27.30 P5 = Ambient, Value = 22.15 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.57 P8 = Supply Pres(psi), Value = 94.71 P9 = Return Pres(psi), Value = 7.02 P10 = Flow Rate(gpm), Value = 0.87 23:24:21 Magnetic Field Measurement Measuring the magnet strength... 23:24:21 Integrated Voltage Measurement... 23:24:23 Magnet Current for MAIN, Imag = 75.0208 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:24:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404949 Vs 23:24:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402496 Vs 23:24:45 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405784 Vs 23:25:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402403 Vs 23:25:06 Magnet Current for MAIN, Imag = 75.0205 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:25:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406665 Vs 23:25:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399229 Vs 23:25:26 Magnet Current for MAIN, Imag = 75.0202 A Vtrans = 0.750201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:25:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404711 Vs 23:25:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014400536 Vs 23:25:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403347 +- 0.000000588 Vs 23:25:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403347 +- 0.000000588 Vs BL = -0.16003718 +- 0.00000653 Tm 23:25:49 Position moved: 0.000000 m 23:25:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 23:25:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600372 +- 0.0000065 Tm^2/m^n 23:25:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600372 +- 0.0000065 Tm^2/m^n 23:25:52 Position moved: 0.000000 m 23:25:52 Magnet system MAIN current ramping to 125.0000 A... 23:26:31 Magnet system MAIN current ramping to 0.0000 A... 23:27:53 Magnet system MAIN current ramping to 125.0000 A... 23:29:14 Magnet system MAIN current ramping to 0.0000 A... 23:30:36 Magnet system MAIN current ramping to 125.0000 A... 23:31:57 Magnet system MAIN current ramping to 0.0000 A... 23:33:21 Position moved: 0.000000 m 23:33:24 Magnet system MAIN current ramping to 87.5000 A... 23:34:26 Magnet Current for MAIN, Imag = 87.4666 A Vtrans = 0.874665 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:34:28 Main (V) Voltage Measurement, V = 3.112692 V 23:34:34 Temperature Measurement, Probe Number = 0, T = 25.948000 C 23:34:36 Temperature Measurement, Probe Number = 1, T = 27.554000 C 23:34:38 Temperature Measurement, Probe Number = 2, T = 27.333000 C 23:34:40 Temperature Measurement, Probe Number = 3, T = 22.053000 C 23:34:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319308 V 23:34:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319308 (V, A, ohm, ...), Measured Value = 28.323729 (C, atm, Hz, ...) 23:34:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328511 V 23:34:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328511 (V, A, ohm, ...), Measured Value = 28.451535 (C, atm, Hz, ...) 23:34:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259064 V 23:34:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259064 (V, A, ohm, ...), Measured Value = 94.429807 (C, atm, Hz, ...) 23:34:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093730 V 23:34:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093730 (V, A, ohm, ...), Measured Value = 7.029787 (C, atm, Hz, ...) 23:34:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 23:34:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885169 (C, atm, Hz, ...) 23:34:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 25.95 P3 = Right Coil Outgoing Side, Value = 27.55 P4 = Left Coil Middle, Value = 27.33 P5 = Ambient, Value = 22.05 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.45 P8 = Supply Pres(psi), Value = 94.43 P9 = Return Pres(psi), Value = 7.03 P10 = Flow Rate(gpm), Value = 0.89 23:34:56 Magnetic Field Measurement Measuring the magnet strength... 23:34:56 Integrated Voltage Measurement... 23:34:58 Magnet Current for MAIN, Imag = 87.4661 A Vtrans = 0.874660 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:35:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778283 Vs 23:35:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773699 Vs 23:35:20 Magnet Current for MAIN, Imag = 87.4669 A Vtrans = 0.874668 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:35:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016783295 Vs 23:35:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771787 Vs 23:35:41 Magnet Current for MAIN, Imag = 87.4667 A Vtrans = 0.874666 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:35:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778904 Vs 23:36:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774929 Vs 23:36:02 Magnet Current for MAIN, Imag = 87.4667 A Vtrans = 0.874666 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:36:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777704 Vs 23:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775625 Vs 23:36:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776778 +- 0.000000555 Vs 23:36:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776778 +- 0.000000555 Vs BL = -0.18640865 +- 0.00000617 Tm 23:36:25 Position moved: 0.000000 m 23:36:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00001 -0.18641 0.00000 23:36:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00001 SL = -0.1864086 +- 0.0000062 Tm^2/m^n 23:36:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864086 +- 0.0000062 Tm^2/m^n 23:36:27 Position moved: 0.000000 m 23:36:27 Magnet system MAIN current ramping to 75.0000 A... 23:36:48 Magnet Current for MAIN, Imag = 75.0202 A Vtrans = 0.750201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:36:50 Main (V) Voltage Measurement, V = 2.671629 V 23:36:55 Temperature Measurement, Probe Number = 0, T = 25.948000 C 23:36:57 Temperature Measurement, Probe Number = 1, T = 27.599000 C 23:36:59 Temperature Measurement, Probe Number = 2, T = 27.461000 C 23:37:01 Temperature Measurement, Probe Number = 3, T = 21.979000 C 23:37:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319872 V 23:37:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319872 (V, A, ohm, ...), Measured Value = 28.331551 (C, atm, Hz, ...) 23:37:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.321342 V 23:37:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321342 (V, A, ohm, ...), Measured Value = 28.351968 (C, atm, Hz, ...) 23:37:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263030 V 23:37:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263030 (V, A, ohm, ...), Measured Value = 94.727220 (C, atm, Hz, ...) 23:37:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093646 V 23:37:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093646 (V, A, ohm, ...), Measured Value = 7.023487 (C, atm, Hz, ...) 23:37:18 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 23:37:18 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887607 (C, atm, Hz, ...) 23:37:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.95 P3 = Right Coil Outgoing Side, Value = 27.60 P4 = Left Coil Middle, Value = 27.46 P5 = Ambient, Value = 21.98 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.35 P8 = Supply Pres(psi), Value = 94.73 P9 = Return Pres(psi), Value = 7.02 P10 = Flow Rate(gpm), Value = 0.89 23:37:18 Magnet system MAIN current ramping to 125.0000 A... 23:37:59 Magnet Current for MAIN, Imag = 124.9893 A Vtrans = 1.249892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:38:01 Main (V) Voltage Measurement, V = 4.455438 V 23:38:06 Temperature Measurement, Probe Number = 0, T = 25.941000 C 23:38:08 Temperature Measurement, Probe Number = 1, T = 27.659000 C 23:38:10 Temperature Measurement, Probe Number = 2, T = 27.509000 C 23:38:13 Temperature Measurement, Probe Number = 3, T = 21.942000 C 23:38:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320053 V 23:38:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320053 (V, A, ohm, ...), Measured Value = 28.334064 (C, atm, Hz, ...) 23:38:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.323687 V 23:38:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323687 (V, A, ohm, ...), Measured Value = 28.384547 (C, atm, Hz, ...) 23:38:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.261300 V 23:38:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.261300 (V, A, ohm, ...), Measured Value = 94.597500 (C, atm, Hz, ...) 23:38:21 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093809 V 23:38:21 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093809 (V, A, ohm, ...), Measured Value = 7.035697 (C, atm, Hz, ...) 23:38:29 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 23:38:29 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.888590 (C, atm, Hz, ...) 23:38:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.94 P3 = Right Coil Outgoing Side, Value = 27.66 P4 = Left Coil Middle, Value = 27.51 P5 = Ambient, Value = 21.94 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.38 P8 = Supply Pres(psi), Value = 94.60 P9 = Return Pres(psi), Value = 7.04 P10 = Flow Rate(gpm), Value = 0.89 23:38:29 Magnet system MAIN current ramping to 0.0000 A... 23:39:53 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:39:55 Main (V) Voltage Measurement, V = -0.000003 V 23:40:00 Temperature Measurement, Probe Number = 0, T = 25.933000 C 23:40:02 Temperature Measurement, Probe Number = 1, T = 27.814000 C 23:40:05 Temperature Measurement, Probe Number = 2, T = 27.505000 C 23:40:07 Temperature Measurement, Probe Number = 3, T = 21.960000 C 23:40:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320046 V 23:40:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320046 (V, A, ohm, ...), Measured Value = 28.333974 (C, atm, Hz, ...) 23:40:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333163 V 23:40:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333163 (V, A, ohm, ...), Measured Value = 28.516156 (C, atm, Hz, ...) 23:40:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266720 V 23:40:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266720 (V, A, ohm, ...), Measured Value = 95.003992 (C, atm, Hz, ...) 23:40:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093982 V 23:40:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093982 (V, A, ohm, ...), Measured Value = 7.048680 (C, atm, Hz, ...) 23:40:23 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 23:40:23 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.887672 (C, atm, Hz, ...) 23:40:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.93 P3 = Right Coil Outgoing Side, Value = 27.81 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 21.96 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.52 P8 = Supply Pres(psi), Value = 95.00 P9 = Return Pres(psi), Value = 7.05 P10 = Flow Rate(gpm), Value = 0.89 23:40:23 Magnet system MAIN current ramping to 125.0000 A... 23:41:47 Magnet Current for MAIN, Imag = 124.9893 A Vtrans = 1.249892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:41:49 Main (V) Voltage Measurement, V = 4.455983 V 23:41:54 Temperature Measurement, Probe Number = 0, T = 25.937000 C 23:41:56 Temperature Measurement, Probe Number = 1, T = 27.578000 C 23:41:58 Temperature Measurement, Probe Number = 2, T = 27.437000 C 23:42:00 Temperature Measurement, Probe Number = 3, T = 21.976000 C 23:42:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319714 V 23:42:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319714 (V, A, ohm, ...), Measured Value = 28.329362 (C, atm, Hz, ...) 23:42:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331033 V 23:42:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331033 (V, A, ohm, ...), Measured Value = 28.486572 (C, atm, Hz, ...) 23:42:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.255304 V 23:42:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.255304 (V, A, ohm, ...), Measured Value = 94.147800 (C, atm, Hz, ...) 23:42:09 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093791 V 23:42:09 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093791 (V, A, ohm, ...), Measured Value = 7.034340 (C, atm, Hz, ...) 23:42:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 23:42:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.893058 (C, atm, Hz, ...) 23:42:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.94 P3 = Right Coil Outgoing Side, Value = 27.58 P4 = Left Coil Middle, Value = 27.44 P5 = Ambient, Value = 21.98 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.49 P8 = Supply Pres(psi), Value = 94.15 P9 = Return Pres(psi), Value = 7.03 P10 = Flow Rate(gpm), Value = 0.89 23:42:17 Magnet system MAIN current ramping to 0.0000 A... 23:43:41 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:43:43 Main (V) Voltage Measurement, V = 0.000000 V 23:43:48 Temperature Measurement, Probe Number = 0, T = 25.936000 C 23:43:50 Temperature Measurement, Probe Number = 1, T = 27.787000 C 23:43:52 Temperature Measurement, Probe Number = 2, T = 27.495000 C 23:43:54 Temperature Measurement, Probe Number = 3, T = 21.919000 C 23:43:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320062 V 23:43:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320062 (V, A, ohm, ...), Measured Value = 28.334189 (C, atm, Hz, ...) 23:43:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.332553 V 23:43:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332553 (V, A, ohm, ...), Measured Value = 28.507688 (C, atm, Hz, ...) 23:44:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.266419 V 23:44:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.266419 (V, A, ohm, ...), Measured Value = 94.981425 (C, atm, Hz, ...) 23:44:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093683 V 23:44:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093683 (V, A, ohm, ...), Measured Value = 7.026203 (C, atm, Hz, ...) 23:44:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000872 V 23:44:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000872 (V, A, ohm, ...), Measured Value = 0.871934 (C, atm, Hz, ...) 23:44:11 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.94 P3 = Right Coil Outgoing Side, Value = 27.79 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 21.92 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.51 P8 = Supply Pres(psi), Value = 94.98 P9 = Return Pres(psi), Value = 7.03 P10 = Flow Rate(gpm), Value = 0.87 23:44:11 Magnet system MAIN current ramping to 125.0000 A... 23:45:34 Magnet Current for MAIN, Imag = 124.9890 A Vtrans = 1.249889 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:45:36 Main (V) Voltage Measurement, V = 4.455823 V 23:45:41 Temperature Measurement, Probe Number = 0, T = 25.934000 C 23:45:43 Temperature Measurement, Probe Number = 1, T = 27.563000 C 23:45:45 Temperature Measurement, Probe Number = 2, T = 27.369000 C 23:45:48 Temperature Measurement, Probe Number = 3, T = 21.905000 C 23:45:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319365 V 23:45:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319365 (V, A, ohm, ...), Measured Value = 28.324519 (C, atm, Hz, ...) 23:45:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331249 V 23:45:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331249 (V, A, ohm, ...), Measured Value = 28.489568 (C, atm, Hz, ...) 23:45:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.262239 V 23:45:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.262239 (V, A, ohm, ...), Measured Value = 94.667932 (C, atm, Hz, ...) 23:45:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093902 V 23:45:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093902 (V, A, ohm, ...), Measured Value = 7.042673 (C, atm, Hz, ...) 23:46:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 23:46:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.891087 (C, atm, Hz, ...) 23:46:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.93 P3 = Right Coil Outgoing Side, Value = 27.56 P4 = Left Coil Middle, Value = 27.37 P5 = Ambient, Value = 21.91 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.49 P8 = Supply Pres(psi), Value = 94.67 P9 = Return Pres(psi), Value = 7.04 P10 = Flow Rate(gpm), Value = 0.89 23:46:04 Magnet system MAIN current ramping to 0.0000 A... 23:47:28 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:47:30 Main (V) Voltage Measurement, V = -0.000003 V 23:47:35 Temperature Measurement, Probe Number = 0, T = 25.934000 C 23:47:37 Temperature Measurement, Probe Number = 1, T = 27.752000 C 23:47:40 Temperature Measurement, Probe Number = 2, T = 27.500000 C 23:47:42 Temperature Measurement, Probe Number = 3, T = 21.972000 C 23:47:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319230 V 23:47:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319230 (V, A, ohm, ...), Measured Value = 28.322636 (C, atm, Hz, ...) 23:47:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.332714 V 23:47:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332714 (V, A, ohm, ...), Measured Value = 28.509912 (C, atm, Hz, ...) 23:47:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.259826 V 23:47:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.259826 (V, A, ohm, ...), Measured Value = 94.486965 (C, atm, Hz, ...) 23:47:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093808 V 23:47:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093808 (V, A, ohm, ...), Measured Value = 7.035600 (C, atm, Hz, ...) 23:47:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 23:47:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888179 (C, atm, Hz, ...) 23:47:58 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.93 P3 = Right Coil Outgoing Side, Value = 27.75 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 21.97 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.51 P8 = Supply Pres(psi), Value = 94.49 P9 = Return Pres(psi), Value = 7.04 P10 = Flow Rate(gpm), Value = 0.89 23:47:58 Magnet system MAIN current ramping to 125.0000 A... 23:49:22 Magnet Current for MAIN, Imag = 124.9894 A Vtrans = 1.249893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:49:24 Main (V) Voltage Measurement, V = 4.455757 V 23:49:29 Temperature Measurement, Probe Number = 0, T = 25.919000 C 23:49:32 Temperature Measurement, Probe Number = 1, T = 27.538000 C 23:49:34 Temperature Measurement, Probe Number = 2, T = 27.428000 C 23:49:36 Temperature Measurement, Probe Number = 3, T = 21.897000 C 23:49:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318260 V 23:49:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318260 (V, A, ohm, ...), Measured Value = 28.309162 (C, atm, Hz, ...) 23:49:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330852 V 23:49:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330852 (V, A, ohm, ...), Measured Value = 28.484061 (C, atm, Hz, ...) 23:49:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.260503 V 23:49:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.260503 (V, A, ohm, ...), Measured Value = 94.537733 (C, atm, Hz, ...) 23:49:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093816 V 23:49:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093816 (V, A, ohm, ...), Measured Value = 7.036177 (C, atm, Hz, ...) 23:49:52 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 23:49:52 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.887492 (C, atm, Hz, ...) 23:49:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.92 P3 = Right Coil Outgoing Side, Value = 27.54 P4 = Left Coil Middle, Value = 27.43 P5 = Ambient, Value = 21.90 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.48 P8 = Supply Pres(psi), Value = 94.54 P9 = Return Pres(psi), Value = 7.04 P10 = Flow Rate(gpm), Value = 0.89 23:49:52 Magnet system MAIN current ramping to 0.0000 A... 23:51:16 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:51:18 Main (V) Voltage Measurement, V = 0.000001 V 23:51:23 Temperature Measurement, Probe Number = 0, T = 25.910000 C 23:51:25 Temperature Measurement, Probe Number = 1, T = 27.754000 C 23:51:27 Temperature Measurement, Probe Number = 2, T = 27.499000 C 23:51:30 Temperature Measurement, Probe Number = 3, T = 21.908000 C 23:51:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319336 V 23:51:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319336 (V, A, ohm, ...), Measured Value = 28.324107 (C, atm, Hz, ...) 23:51:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331990 V 23:51:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331990 (V, A, ohm, ...), Measured Value = 28.499865 (C, atm, Hz, ...) 23:51:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258832 V 23:51:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258832 (V, A, ohm, ...), Measured Value = 94.412370 (C, atm, Hz, ...) 23:51:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093750 V 23:51:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093750 (V, A, ohm, ...), Measured Value = 7.031242 (C, atm, Hz, ...) 23:51:46 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000873 V 23:51:46 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000873 (V, A, ohm, ...), Measured Value = 0.873190 (C, atm, Hz, ...) 23:51:46 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.91 P3 = Right Coil Outgoing Side, Value = 27.75 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 21.91 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.50 P8 = Supply Pres(psi), Value = 94.41 P9 = Return Pres(psi), Value = 7.03 P10 = Flow Rate(gpm), Value = 0.87 23:51:46 Magnet system MAIN current ramping to 75.0000 A... 23:52:41 Magnet Current for MAIN, Imag = 75.0200 A Vtrans = 0.750199 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:52:43 Main (V) Voltage Measurement, V = 2.668328 V 23:52:48 Temperature Measurement, Probe Number = 0, T = 25.912000 C 23:52:51 Temperature Measurement, Probe Number = 1, T = 27.490000 C 23:52:53 Temperature Measurement, Probe Number = 2, T = 27.256000 C 23:52:55 Temperature Measurement, Probe Number = 3, T = 21.876000 C 23:52:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319580 V 23:52:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319580 (V, A, ohm, ...), Measured Value = 28.327497 (C, atm, Hz, ...) 23:52:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333866 V 23:52:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333866 (V, A, ohm, ...), Measured Value = 28.525915 (C, atm, Hz, ...) 23:53:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.262766 V 23:53:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.262766 (V, A, ohm, ...), Measured Value = 94.707457 (C, atm, Hz, ...) 23:53:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094073 V 23:53:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094073 (V, A, ohm, ...), Measured Value = 7.055460 (C, atm, Hz, ...) 23:53:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000866 V 23:53:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000866 (V, A, ohm, ...), Measured Value = 0.866072 (C, atm, Hz, ...) 23:53:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.91 P3 = Right Coil Outgoing Side, Value = 27.49 P4 = Left Coil Middle, Value = 27.26 P5 = Ambient, Value = 21.88 P6 = Supply Temp(C), Value = 28.33 P7 = Return Temp(C), Value = 28.53 P8 = Supply Pres(psi), Value = 94.71 P9 = Return Pres(psi), Value = 7.06 P10 = Flow Rate(gpm), Value = 0.87 23:53:11 Magnetic Field Measurement Measuring the magnet strength... 23:53:11 Integrated Voltage Measurement... 23:53:13 Magnet Current for MAIN, Imag = 75.0201 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:53:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014396899 Vs 23:53:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014409089 Vs 23:53:35 Magnet Current for MAIN, Imag = 75.0204 A Vtrans = 0.750203 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:53:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014398054 Vs 23:53:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014406160 Vs 23:53:56 Magnet Current for MAIN, Imag = 75.0201 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:54:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401611 Vs 23:54:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405177 Vs 23:54:17 Magnet Current for MAIN, Imag = 75.0200 A Vtrans = 0.750199 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 23:54:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014398578 Vs 23:54:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405734 Vs 23:54:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402663 +- 0.000000550 Vs 23:54:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014402663 +- 0.000000550 Vs BL = -0.16002959 +- 0.00000611 Tm 23:54:40 Position moved: 0.000000 m 23:54:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16003 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16003 0.00001 -0.16003 0.00000 23:54:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16003 0.00001 SL = -0.1600296 +- 0.0000061 Tm^2/m^n 23:54:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600296 +- 0.0000061 Tm^2/m^n 23:54:43 Position moved: 0.000000 m 23:54:43 Magnet system MAIN current ramping to 125.0000 A... 23:55:22 Magnet system MAIN current ramping to 0.0000 A... 23:56:44 Magnet system MAIN current ramping to 125.0000 A... 23:58:05 Magnet system MAIN current ramping to 0.0000 A... 23:59:27 Magnet system MAIN current ramping to 125.0000 A... 00:00:49 Magnet system MAIN current ramping to 0.0000 A... 00:02:14 Position moved: 0.000000 m 00:02:17 Magnet system MAIN current ramping to 87.5000 A... 00:03:20 Magnet Current for MAIN, Imag = 87.4661 A Vtrans = 0.874660 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:03:22 Main (V) Voltage Measurement, V = 3.112502 V 00:03:27 Temperature Measurement, Probe Number = 0, T = 25.860000 C 00:03:29 Temperature Measurement, Probe Number = 1, T = 27.533000 C 00:03:31 Temperature Measurement, Probe Number = 2, T = 27.360000 C 00:03:33 Temperature Measurement, Probe Number = 3, T = 21.788000 C 00:03:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318725 V 00:03:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318725 (V, A, ohm, ...), Measured Value = 28.315621 (C, atm, Hz, ...) 00:03:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.327273 V 00:03:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327273 (V, A, ohm, ...), Measured Value = 28.434349 (C, atm, Hz, ...) 00:03:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.260668 V 00:03:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.260668 (V, A, ohm, ...), Measured Value = 94.550130 (C, atm, Hz, ...) 00:03:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094136 V 00:03:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094136 (V, A, ohm, ...), Measured Value = 7.060208 (C, atm, Hz, ...) 00:03:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 00:03:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877752 (C, atm, Hz, ...) 00:03:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 25.86 P3 = Right Coil Outgoing Side, Value = 27.53 P4 = Left Coil Middle, Value = 27.36 P5 = Ambient, Value = 21.79 P6 = Supply Temp(C), Value = 28.32 P7 = Return Temp(C), Value = 28.43 P8 = Supply Pres(psi), Value = 94.55 P9 = Return Pres(psi), Value = 7.06 P10 = Flow Rate(gpm), Value = 0.88 00:03:50 Magnetic Field Measurement Measuring the magnet strength... 00:03:50 Integrated Voltage Measurement... 00:03:52 Magnet Current for MAIN, Imag = 87.4663 A Vtrans = 0.874663 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:04:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016769241 Vs 00:04:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775900 Vs 00:04:14 Magnet Current for MAIN, Imag = 87.4666 A Vtrans = 0.874665 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:04:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016769289 Vs 00:04:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016777089 Vs 00:04:35 Magnet Current for MAIN, Imag = 87.4661 A Vtrans = 0.874660 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:04:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016770117 Vs 00:04:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016776986 Vs 00:04:55 Magnet Current for MAIN, Imag = 87.4666 A Vtrans = 0.874665 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774971 Vs 00:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016778545 Vs 00:05:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774017 +- 0.000001621 Vs 00:05:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016774017 +- 0.000001621 Vs BL = -0.18637797 +- 0.00001801 Tm 00:05:18 Position moved: 0.000000 m 00:05:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18638 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18638 0.00002 -0.18638 0.00000 00:05:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18638 0.00002 SL = -0.1863780 +- 0.0000180 Tm^2/m^n 00:05:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863780 +- 0.0000180 Tm^2/m^n 00:05:20 Position moved: 0.000000 m 00:05:20 Magnet system MAIN current ramping to 75.0000 A... 00:05:41 Magnet Current for MAIN, Imag = 75.0204 A Vtrans = 0.750203 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:05:43 Main (V) Voltage Measurement, V = 2.671430 V 00:05:48 Temperature Measurement, Probe Number = 0, T = 25.858000 C 00:05:50 Temperature Measurement, Probe Number = 1, T = 27.562000 C 00:05:52 Temperature Measurement, Probe Number = 2, T = 27.460000 C 00:05:54 Temperature Measurement, Probe Number = 3, T = 21.796000 C 00:05:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318424 V 00:05:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318424 (V, A, ohm, ...), Measured Value = 28.311440 (C, atm, Hz, ...) 00:05:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.320180 V 00:05:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320180 (V, A, ohm, ...), Measured Value = 28.335839 (C, atm, Hz, ...) 00:06:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263679 V 00:06:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263679 (V, A, ohm, ...), Measured Value = 94.775948 (C, atm, Hz, ...) 00:06:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094035 V 00:06:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094035 (V, A, ohm, ...), Measured Value = 7.052648 (C, atm, Hz, ...) 00:06:11 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 00:06:11 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892631 (C, atm, Hz, ...) 00:06:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.86 P3 = Right Coil Outgoing Side, Value = 27.56 P4 = Left Coil Middle, Value = 27.46 P5 = Ambient, Value = 21.80 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.34 P8 = Supply Pres(psi), Value = 94.78 P9 = Return Pres(psi), Value = 7.05 P10 = Flow Rate(gpm), Value = 0.89 00:06:11 Magnet system MAIN current ramping to 125.0000 A... 00:06:52 Magnet Current for MAIN, Imag = 124.9857 A Vtrans = 1.249856 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:06:54 Main (V) Voltage Measurement, V = 4.455242 V 00:07:00 Temperature Measurement, Probe Number = 0, T = 25.873000 C 00:07:02 Temperature Measurement, Probe Number = 1, T = 27.605000 C 00:07:04 Temperature Measurement, Probe Number = 2, T = 27.497000 C 00:07:06 Temperature Measurement, Probe Number = 3, T = 21.840000 C 00:07:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318496 V 00:07:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318496 (V, A, ohm, ...), Measured Value = 28.312446 (C, atm, Hz, ...) 00:07:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.322489 V 00:07:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322489 (V, A, ohm, ...), Measured Value = 28.367899 (C, atm, Hz, ...) 00:07:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272556 V 00:07:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272556 (V, A, ohm, ...), Measured Value = 95.441685 (C, atm, Hz, ...) 00:07:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094155 V 00:07:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094155 (V, A, ohm, ...), Measured Value = 7.061655 (C, atm, Hz, ...) 00:07:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000876 V 00:07:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000876 (V, A, ohm, ...), Measured Value = 0.875511 (C, atm, Hz, ...) 00:07:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.87 P3 = Right Coil Outgoing Side, Value = 27.61 P4 = Left Coil Middle, Value = 27.50 P5 = Ambient, Value = 21.84 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.37 P8 = Supply Pres(psi), Value = 95.44 P9 = Return Pres(psi), Value = 7.06 P10 = Flow Rate(gpm), Value = 0.88 00:07:22 Magnet system MAIN current ramping to 0.0000 A... 00:08:46 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:08:48 Main (V) Voltage Measurement, V = -0.000004 V 00:08:53 Temperature Measurement, Probe Number = 0, T = 25.856000 C 00:08:55 Temperature Measurement, Probe Number = 1, T = 27.759000 C 00:08:57 Temperature Measurement, Probe Number = 2, T = 27.523000 C 00:09:00 Temperature Measurement, Probe Number = 3, T = 21.822000 C 00:09:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318100 V 00:09:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318100 (V, A, ohm, ...), Measured Value = 28.306938 (C, atm, Hz, ...) 00:09:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331904 V 00:09:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331904 (V, A, ohm, ...), Measured Value = 28.498664 (C, atm, Hz, ...) 00:09:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264113 V 00:09:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264113 (V, A, ohm, ...), Measured Value = 94.808498 (C, atm, Hz, ...) 00:09:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094065 V 00:09:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094065 (V, A, ohm, ...), Measured Value = 7.054875 (C, atm, Hz, ...) 00:09:16 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 00:09:16 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.889589 (C, atm, Hz, ...) 00:09:16 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.86 P3 = Right Coil Outgoing Side, Value = 27.76 P4 = Left Coil Middle, Value = 27.52 P5 = Ambient, Value = 21.82 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.50 P8 = Supply Pres(psi), Value = 94.81 P9 = Return Pres(psi), Value = 7.05 P10 = Flow Rate(gpm), Value = 0.89 00:09:16 Magnet system MAIN current ramping to 125.0000 A... 00:10:40 Magnet Current for MAIN, Imag = 124.9894 A Vtrans = 1.249893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:10:42 Main (V) Voltage Measurement, V = 4.455521 V 00:10:47 Temperature Measurement, Probe Number = 0, T = 25.854000 C 00:10:49 Temperature Measurement, Probe Number = 1, T = 27.542000 C 00:10:51 Temperature Measurement, Probe Number = 2, T = 27.422000 C 00:10:53 Temperature Measurement, Probe Number = 3, T = 21.901000 C 00:10:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317588 V 00:10:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317588 (V, A, ohm, ...), Measured Value = 28.299833 (C, atm, Hz, ...) 00:10:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.329664 V 00:10:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329664 (V, A, ohm, ...), Measured Value = 28.467556 (C, atm, Hz, ...) 00:11:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.254830 V 00:11:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.254830 (V, A, ohm, ...), Measured Value = 94.112250 (C, atm, Hz, ...) 00:11:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.093984 V 00:11:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.093984 (V, A, ohm, ...), Measured Value = 7.048777 (C, atm, Hz, ...) 00:11:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 00:11:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895614 (C, atm, Hz, ...) 00:11:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.85 P3 = Right Coil Outgoing Side, Value = 27.54 P4 = Left Coil Middle, Value = 27.42 P5 = Ambient, Value = 21.90 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.47 P8 = Supply Pres(psi), Value = 94.11 P9 = Return Pres(psi), Value = 7.05 P10 = Flow Rate(gpm), Value = 0.90 00:11:10 Magnet system MAIN current ramping to 0.0000 A... 00:12:33 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:12:35 Main (V) Voltage Measurement, V = 0.000000 V 00:12:40 Temperature Measurement, Probe Number = 0, T = 25.861000 C 00:12:42 Temperature Measurement, Probe Number = 1, T = 27.733000 C 00:12:44 Temperature Measurement, Probe Number = 2, T = 27.457000 C 00:12:46 Temperature Measurement, Probe Number = 3, T = 21.913000 C 00:12:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317796 V 00:12:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317796 (V, A, ohm, ...), Measured Value = 28.302722 (C, atm, Hz, ...) 00:12:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330320 V 00:12:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330320 (V, A, ohm, ...), Measured Value = 28.476669 (C, atm, Hz, ...) 00:12:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.264584 V 00:12:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.264584 (V, A, ohm, ...), Measured Value = 94.843763 (C, atm, Hz, ...) 00:12:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094132 V 00:12:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094132 (V, A, ohm, ...), Measured Value = 7.059915 (C, atm, Hz, ...) 00:13:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 00:13:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878138 (C, atm, Hz, ...) 00:13:03 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.86 P3 = Right Coil Outgoing Side, Value = 27.73 P4 = Left Coil Middle, Value = 27.46 P5 = Ambient, Value = 21.91 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.48 P8 = Supply Pres(psi), Value = 94.84 P9 = Return Pres(psi), Value = 7.06 P10 = Flow Rate(gpm), Value = 0.88 00:13:03 Magnet system MAIN current ramping to 125.0000 A... 00:14:26 Magnet Current for MAIN, Imag = 124.9891 A Vtrans = 1.249891 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:14:29 Main (V) Voltage Measurement, V = 4.455452 V 00:14:34 Temperature Measurement, Probe Number = 0, T = 25.854000 C 00:14:36 Temperature Measurement, Probe Number = 1, T = 27.508000 C 00:14:38 Temperature Measurement, Probe Number = 2, T = 27.395000 C 00:14:40 Temperature Measurement, Probe Number = 3, T = 21.845000 C 00:14:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318089 V 00:14:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318089 (V, A, ohm, ...), Measured Value = 28.306794 (C, atm, Hz, ...) 00:14:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.329509 V 00:14:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329509 (V, A, ohm, ...), Measured Value = 28.465403 (C, atm, Hz, ...) 00:14:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.260121 V 00:14:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.260121 (V, A, ohm, ...), Measured Value = 94.509052 (C, atm, Hz, ...) 00:14:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094404 V 00:14:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094404 (V, A, ohm, ...), Measured Value = 7.080263 (C, atm, Hz, ...) 00:14:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 00:14:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890319 (C, atm, Hz, ...) 00:14:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.85 P3 = Right Coil Outgoing Side, Value = 27.51 P4 = Left Coil Middle, Value = 27.39 P5 = Ambient, Value = 21.84 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.47 P8 = Supply Pres(psi), Value = 94.51 P9 = Return Pres(psi), Value = 7.08 P10 = Flow Rate(gpm), Value = 0.89 00:14:56 Magnet system MAIN current ramping to 0.0000 A... 00:16:20 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:16:22 Main (V) Voltage Measurement, V = 0.000003 V 00:16:27 Temperature Measurement, Probe Number = 0, T = 25.848000 C 00:16:30 Temperature Measurement, Probe Number = 1, T = 27.710000 C 00:16:32 Temperature Measurement, Probe Number = 2, T = 27.493000 C 00:16:34 Temperature Measurement, Probe Number = 3, T = 21.840000 C 00:16:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317753 V 00:16:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317753 (V, A, ohm, ...), Measured Value = 28.302131 (C, atm, Hz, ...) 00:16:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330691 V 00:16:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330691 (V, A, ohm, ...), Measured Value = 28.481818 (C, atm, Hz, ...) 00:16:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.261675 V 00:16:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.261675 (V, A, ohm, ...), Measured Value = 94.625595 (C, atm, Hz, ...) 00:16:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094031 V 00:16:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094031 (V, A, ohm, ...), Measured Value = 7.052355 (C, atm, Hz, ...) 00:16:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000876 V 00:16:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000876 (V, A, ohm, ...), Measured Value = 0.875581 (C, atm, Hz, ...) 00:16:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.85 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.49 P5 = Ambient, Value = 21.84 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.48 P8 = Supply Pres(psi), Value = 94.63 P9 = Return Pres(psi), Value = 7.05 P10 = Flow Rate(gpm), Value = 0.88 00:16:50 Magnet system MAIN current ramping to 125.0000 A... 00:18:14 Magnet Current for MAIN, Imag = 124.9894 A Vtrans = 1.249893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:18:16 Main (V) Voltage Measurement, V = 4.455412 V 00:18:21 Temperature Measurement, Probe Number = 0, T = 25.841000 C 00:18:23 Temperature Measurement, Probe Number = 1, T = 27.500000 C 00:18:25 Temperature Measurement, Probe Number = 2, T = 27.401000 C 00:18:27 Temperature Measurement, Probe Number = 3, T = 21.822000 C 00:18:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317734 V 00:18:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317734 (V, A, ohm, ...), Measured Value = 28.301861 (C, atm, Hz, ...) 00:18:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.329194 V 00:18:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329194 (V, A, ohm, ...), Measured Value = 28.461025 (C, atm, Hz, ...) 00:18:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258227 V 00:18:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258227 (V, A, ohm, ...), Measured Value = 94.367033 (C, atm, Hz, ...) 00:18:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094256 V 00:18:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094256 (V, A, ohm, ...), Measured Value = 7.069215 (C, atm, Hz, ...) 00:18:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000885 V 00:18:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000885 (V, A, ohm, ...), Measured Value = 0.885373 (C, atm, Hz, ...) 00:18:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.84 P3 = Right Coil Outgoing Side, Value = 27.50 P4 = Left Coil Middle, Value = 27.40 P5 = Ambient, Value = 21.82 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.46 P8 = Supply Pres(psi), Value = 94.37 P9 = Return Pres(psi), Value = 7.07 P10 = Flow Rate(gpm), Value = 0.89 00:18:44 Magnet system MAIN current ramping to 0.0000 A... 00:20:08 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:20:10 Main (V) Voltage Measurement, V = -0.000004 V 00:20:15 Temperature Measurement, Probe Number = 0, T = 25.839000 C 00:20:17 Temperature Measurement, Probe Number = 1, T = 27.702000 C 00:20:20 Temperature Measurement, Probe Number = 2, T = 27.453000 C 00:20:22 Temperature Measurement, Probe Number = 3, T = 21.746000 C 00:20:24 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317906 V 00:20:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317906 (V, A, ohm, ...), Measured Value = 28.304247 (C, atm, Hz, ...) 00:20:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.330152 V 00:20:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330152 (V, A, ohm, ...), Measured Value = 28.474337 (C, atm, Hz, ...) 00:20:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.261317 V 00:20:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.261317 (V, A, ohm, ...), Measured Value = 94.598760 (C, atm, Hz, ...) 00:20:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094211 V 00:20:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094211 (V, A, ohm, ...), Measured Value = 7.065825 (C, atm, Hz, ...) 00:20:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 00:20:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.877788 (C, atm, Hz, ...) 00:20:38 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.84 P3 = Right Coil Outgoing Side, Value = 27.70 P4 = Left Coil Middle, Value = 27.45 P5 = Ambient, Value = 21.75 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.47 P8 = Supply Pres(psi), Value = 94.60 P9 = Return Pres(psi), Value = 7.07 P10 = Flow Rate(gpm), Value = 0.88 00:20:38 Magnet system MAIN current ramping to 75.0000 A... 00:21:34 Magnet Current for MAIN, Imag = 75.0201 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:21:36 Main (V) Voltage Measurement, V = 2.668108 V 00:21:41 Temperature Measurement, Probe Number = 0, T = 25.840000 C 00:21:43 Temperature Measurement, Probe Number = 1, T = 27.456000 C 00:21:45 Temperature Measurement, Probe Number = 2, T = 27.242000 C 00:21:47 Temperature Measurement, Probe Number = 3, T = 21.832000 C 00:21:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317866 V 00:21:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317866 (V, A, ohm, ...), Measured Value = 28.303690 (C, atm, Hz, ...) 00:21:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.331825 V 00:21:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331825 (V, A, ohm, ...), Measured Value = 28.497569 (C, atm, Hz, ...) 00:21:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.262704 V 00:21:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.262704 (V, A, ohm, ...), Measured Value = 94.702808 (C, atm, Hz, ...) 00:21:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094347 V 00:21:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094347 (V, A, ohm, ...), Measured Value = 7.075995 (C, atm, Hz, ...) 00:22:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 00:22:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895397 (C, atm, Hz, ...) 00:22:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.84 P3 = Right Coil Outgoing Side, Value = 27.46 P4 = Left Coil Middle, Value = 27.24 P5 = Ambient, Value = 21.83 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.50 P8 = Supply Pres(psi), Value = 94.70 P9 = Return Pres(psi), Value = 7.08 P10 = Flow Rate(gpm), Value = 0.90 00:22:03 Magnetic Field Measurement Measuring the magnet strength... 00:22:03 Integrated Voltage Measurement... 00:22:06 Magnet Current for MAIN, Imag = 75.0201 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:22:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399761 Vs 00:22:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401287 Vs 00:22:28 Magnet Current for MAIN, Imag = 75.0197 A Vtrans = 0.750196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:22:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014397266 Vs 00:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014404524 Vs 00:22:48 Magnet Current for MAIN, Imag = 75.0199 A Vtrans = 0.750198 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403794 Vs 00:23:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401473 Vs 00:23:09 Magnet Current for MAIN, Imag = 75.0200 A Vtrans = 0.750199 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402133 Vs 00:23:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014405193 Vs 00:23:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401929 +- 0.000001279 Vs 00:23:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401929 +- 0.000001279 Vs BL = -0.16002143 +- 0.00001421 Tm 00:23:32 Position moved: 0.000000 m 00:23:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16002 0.00001 -0.16002 0.00000 00:23:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16002 0.00001 SL = -0.1600214 +- 0.0000142 Tm^2/m^n 00:23:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600214 +- 0.0000142 Tm^2/m^n 00:23:35 Position moved: 0.000000 m 00:23:35 Magnet system MAIN current ramping to 125.0000 A... 00:24:14 Magnet system MAIN current ramping to 0.0000 A... 00:25:35 Magnet system MAIN current ramping to 125.0000 A... 00:26:57 Magnet system MAIN current ramping to 0.0000 A... 00:28:19 Magnet system MAIN current ramping to 125.0000 A... 00:29:40 Magnet system MAIN current ramping to 0.0000 A... 00:31:05 Position moved: 0.000000 m 00:31:08 Magnet system MAIN current ramping to 87.5000 A... 00:32:11 Magnet Current for MAIN, Imag = 87.4663 A Vtrans = 0.874663 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:32:13 Main (V) Voltage Measurement, V = 3.112334 V 00:32:18 Temperature Measurement, Probe Number = 0, T = 25.798000 C 00:32:20 Temperature Measurement, Probe Number = 1, T = 27.453000 C 00:32:22 Temperature Measurement, Probe Number = 2, T = 27.237000 C 00:32:24 Temperature Measurement, Probe Number = 3, T = 21.843000 C 00:32:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317733 V 00:32:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317733 (V, A, ohm, ...), Measured Value = 28.301843 (C, atm, Hz, ...) 00:32:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.323993 V 00:32:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323993 (V, A, ohm, ...), Measured Value = 28.388799 (C, atm, Hz, ...) 00:32:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.267272 V 00:32:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.267272 (V, A, ohm, ...), Measured Value = 95.045363 (C, atm, Hz, ...) 00:32:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094451 V 00:32:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094451 (V, A, ohm, ...), Measured Value = 7.083840 (C, atm, Hz, ...) 00:32:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 00:32:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900282 (C, atm, Hz, ...) 00:32:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.11 P2 = Core, Value = 25.80 P3 = Right Coil Outgoing Side, Value = 27.45 P4 = Left Coil Middle, Value = 27.24 P5 = Ambient, Value = 21.84 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.39 P8 = Supply Pres(psi), Value = 95.05 P9 = Return Pres(psi), Value = 7.08 P10 = Flow Rate(gpm), Value = 0.90 00:32:41 Magnetic Field Measurement Measuring the magnet strength... 00:32:41 Integrated Voltage Measurement... 00:32:43 Magnet Current for MAIN, Imag = 87.4658 A Vtrans = 0.874657 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778525 Vs 00:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774333 Vs 00:33:05 Magnet Current for MAIN, Imag = 87.4665 A Vtrans = 0.874664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776628 Vs 00:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773448 Vs 00:33:26 Magnet Current for MAIN, Imag = 87.4663 A Vtrans = 0.874663 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:33:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777966 Vs 00:33:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773549 Vs 00:33:46 Magnet Current for MAIN, Imag = 87.4662 A Vtrans = 0.874661 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:33:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780240 Vs 00:34:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016775401 Vs 00:34:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776261 +- 0.000001026 Vs 00:34:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776261 +- 0.000001026 Vs BL = -0.18640290 +- 0.00001140 Tm 00:34:09 Position moved: 0.000000 m 00:34:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18640 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18640 0.00001 -0.18640 0.00000 00:34:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18640 0.00001 SL = -0.1864029 +- 0.0000114 Tm^2/m^n 00:34:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864029 +- 0.0000114 Tm^2/m^n 00:34:12 Position moved: 0.000000 m 00:34:12 Magnet system MAIN current ramping to 75.0000 A... 00:34:32 Magnet Current for MAIN, Imag = 75.0199 A Vtrans = 0.750198 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:34:34 Main (V) Voltage Measurement, V = 2.671281 V 00:34:39 Temperature Measurement, Probe Number = 0, T = 25.804000 C 00:34:41 Temperature Measurement, Probe Number = 1, T = 27.514000 C 00:34:43 Temperature Measurement, Probe Number = 2, T = 27.325000 C 00:34:45 Temperature Measurement, Probe Number = 3, T = 21.815000 C 00:34:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317610 V 00:34:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317610 (V, A, ohm, ...), Measured Value = 28.300139 (C, atm, Hz, ...) 00:34:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.316786 V 00:34:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316786 (V, A, ohm, ...), Measured Value = 28.288693 (C, atm, Hz, ...) 00:34:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.250817 V 00:34:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.250817 (V, A, ohm, ...), Measured Value = 93.811253 (C, atm, Hz, ...) 00:34:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094459 V 00:34:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094459 (V, A, ohm, ...), Measured Value = 7.084425 (C, atm, Hz, ...) 00:35:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000895 V 00:35:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000895 (V, A, ohm, ...), Measured Value = 0.895365 (C, atm, Hz, ...) 00:35:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.80 P3 = Right Coil Outgoing Side, Value = 27.51 P4 = Left Coil Middle, Value = 27.32 P5 = Ambient, Value = 21.82 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.29 P8 = Supply Pres(psi), Value = 93.81 P9 = Return Pres(psi), Value = 7.08 P10 = Flow Rate(gpm), Value = 0.90 00:35:02 Magnet system MAIN current ramping to 125.0000 A... 00:35:43 Magnet Current for MAIN, Imag = 124.9879 A Vtrans = 1.249878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:35:45 Main (V) Voltage Measurement, V = 4.454952 V 00:35:50 Temperature Measurement, Probe Number = 0, T = 25.812000 C 00:35:52 Temperature Measurement, Probe Number = 1, T = 27.571000 C 00:35:54 Temperature Measurement, Probe Number = 2, T = 27.363000 C 00:35:57 Temperature Measurement, Probe Number = 3, T = 21.796000 C 00:35:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317458 V 00:35:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317458 (V, A, ohm, ...), Measured Value = 28.298022 (C, atm, Hz, ...) 00:36:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.319368 V 00:36:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319368 (V, A, ohm, ...), Measured Value = 28.324556 (C, atm, Hz, ...) 00:36:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.251110 V 00:36:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.251110 (V, A, ohm, ...), Measured Value = 93.833242 (C, atm, Hz, ...) 00:36:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094250 V 00:36:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094250 (V, A, ohm, ...), Measured Value = 7.068727 (C, atm, Hz, ...) 00:36:13 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 00:36:13 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878113 (C, atm, Hz, ...) 00:36:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.45 P2 = Core, Value = 25.81 P3 = Right Coil Outgoing Side, Value = 27.57 P4 = Left Coil Middle, Value = 27.36 P5 = Ambient, Value = 21.80 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.32 P8 = Supply Pres(psi), Value = 93.83 P9 = Return Pres(psi), Value = 7.07 P10 = Flow Rate(gpm), Value = 0.88 00:36:13 Magnet system MAIN current ramping to 0.0000 A... 00:37:37 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:37:39 Main (V) Voltage Measurement, V = -0.000001 V 00:37:44 Temperature Measurement, Probe Number = 0, T = 25.803000 C 00:37:46 Temperature Measurement, Probe Number = 1, T = 27.725000 C 00:37:48 Temperature Measurement, Probe Number = 2, T = 27.451000 C 00:37:50 Temperature Measurement, Probe Number = 3, T = 21.751000 C 00:37:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317592 V 00:37:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317592 (V, A, ohm, ...), Measured Value = 28.299887 (C, atm, Hz, ...) 00:37:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328781 V 00:37:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328781 (V, A, ohm, ...), Measured Value = 28.455285 (C, atm, Hz, ...) 00:37:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258265 V 00:37:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258265 (V, A, ohm, ...), Measured Value = 94.369845 (C, atm, Hz, ...) 00:37:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094555 V 00:37:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094555 (V, A, ohm, ...), Measured Value = 7.091595 (C, atm, Hz, ...) 00:38:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000875 V 00:38:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000875 (V, A, ohm, ...), Measured Value = 0.875487 (C, atm, Hz, ...) 00:38:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 25.80 P3 = Right Coil Outgoing Side, Value = 27.73 P4 = Left Coil Middle, Value = 27.45 P5 = Ambient, Value = 21.75 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.46 P8 = Supply Pres(psi), Value = 94.37 P9 = Return Pres(psi), Value = 7.09 P10 = Flow Rate(gpm), Value = 0.88 00:38:07 Magnet system MAIN current ramping to 125.0000 A... 00:39:31 Magnet Current for MAIN, Imag = 124.9888 A Vtrans = 1.249887 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:39:33 Main (V) Voltage Measurement, V = 4.455562 V 00:39:38 Temperature Measurement, Probe Number = 0, T = 25.806000 C 00:39:40 Temperature Measurement, Probe Number = 1, T = 27.506000 C 00:39:42 Temperature Measurement, Probe Number = 2, T = 27.321000 C 00:39:44 Temperature Measurement, Probe Number = 3, T = 21.722000 C 00:39:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317532 V 00:39:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317532 (V, A, ohm, ...), Measured Value = 28.299062 (C, atm, Hz, ...) 00:39:49 Sensor Voltage Measurement, Sensor Number = 1, V = 2.326346 V 00:39:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326346 (V, A, ohm, ...), Measured Value = 28.421468 (C, atm, Hz, ...) 00:39:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.261441 V 00:39:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.261441 (V, A, ohm, ...), Measured Value = 94.608060 (C, atm, Hz, ...) 00:39:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094642 V 00:39:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094642 (V, A, ohm, ...), Measured Value = 7.098180 (C, atm, Hz, ...) 00:40:01 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000876 V 00:40:01 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000876 (V, A, ohm, ...), Measured Value = 0.875881 (C, atm, Hz, ...) 00:40:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.81 P3 = Right Coil Outgoing Side, Value = 27.51 P4 = Left Coil Middle, Value = 27.32 P5 = Ambient, Value = 21.72 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.42 P8 = Supply Pres(psi), Value = 94.61 P9 = Return Pres(psi), Value = 7.10 P10 = Flow Rate(gpm), Value = 0.88 00:40:01 Magnet system MAIN current ramping to 0.0000 A... 00:41:24 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:41:26 Main (V) Voltage Measurement, V = 0.000000 V 00:41:32 Temperature Measurement, Probe Number = 0, T = 25.794000 C 00:41:34 Temperature Measurement, Probe Number = 1, T = 27.712000 C 00:41:36 Temperature Measurement, Probe Number = 2, T = 27.425000 C 00:41:38 Temperature Measurement, Probe Number = 3, T = 21.854000 C 00:41:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317837 V 00:41:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317837 (V, A, ohm, ...), Measured Value = 28.303296 (C, atm, Hz, ...) 00:41:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328244 V 00:41:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328244 (V, A, ohm, ...), Measured Value = 28.447839 (C, atm, Hz, ...) 00:41:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.261642 V 00:41:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.261642 (V, A, ohm, ...), Measured Value = 94.623173 (C, atm, Hz, ...) 00:41:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094500 V 00:41:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094500 (V, A, ohm, ...), Measured Value = 7.087522 (C, atm, Hz, ...) 00:41:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 00:41:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892906 (C, atm, Hz, ...) 00:41:54 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.79 P3 = Right Coil Outgoing Side, Value = 27.71 P4 = Left Coil Middle, Value = 27.43 P5 = Ambient, Value = 21.85 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.45 P8 = Supply Pres(psi), Value = 94.62 P9 = Return Pres(psi), Value = 7.09 P10 = Flow Rate(gpm), Value = 0.89 00:41:54 Magnet system MAIN current ramping to 125.0000 A... 00:43:18 Magnet Current for MAIN, Imag = 124.9888 A Vtrans = 1.249887 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:43:20 Main (V) Voltage Measurement, V = 4.455285 V 00:43:25 Temperature Measurement, Probe Number = 0, T = 25.799000 C 00:43:27 Temperature Measurement, Probe Number = 1, T = 27.495000 C 00:43:29 Temperature Measurement, Probe Number = 2, T = 27.347000 C 00:43:31 Temperature Measurement, Probe Number = 3, T = 21.777000 C 00:43:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317575 V 00:43:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317575 (V, A, ohm, ...), Measured Value = 28.299654 (C, atm, Hz, ...) 00:43:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.326883 V 00:43:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326883 (V, A, ohm, ...), Measured Value = 28.428931 (C, atm, Hz, ...) 00:43:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.258830 V 00:43:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.258830 (V, A, ohm, ...), Measured Value = 94.412273 (C, atm, Hz, ...) 00:43:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094783 V 00:43:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094783 (V, A, ohm, ...), Measured Value = 7.108740 (C, atm, Hz, ...) 00:43:48 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000880 V 00:43:48 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000880 (V, A, ohm, ...), Measured Value = 0.880416 (C, atm, Hz, ...) 00:43:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.80 P3 = Right Coil Outgoing Side, Value = 27.50 P4 = Left Coil Middle, Value = 27.35 P5 = Ambient, Value = 21.78 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.43 P8 = Supply Pres(psi), Value = 94.41 P9 = Return Pres(psi), Value = 7.11 P10 = Flow Rate(gpm), Value = 0.88 00:43:48 Magnet system MAIN current ramping to 0.0000 A... 00:45:12 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:45:14 Main (V) Voltage Measurement, V = 0.000001 V 00:45:19 Temperature Measurement, Probe Number = 0, T = 25.793000 C 00:45:21 Temperature Measurement, Probe Number = 1, T = 27.694000 C 00:45:23 Temperature Measurement, Probe Number = 2, T = 27.429000 C 00:45:25 Temperature Measurement, Probe Number = 3, T = 21.774000 C 00:45:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318141 V 00:45:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318141 (V, A, ohm, ...), Measured Value = 28.307512 (C, atm, Hz, ...) 00:45:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.327219 V 00:45:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327219 (V, A, ohm, ...), Measured Value = 28.433594 (C, atm, Hz, ...) 00:45:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.265783 V 00:45:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.265783 (V, A, ohm, ...), Measured Value = 94.933763 (C, atm, Hz, ...) 00:45:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094402 V 00:45:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094402 (V, A, ohm, ...), Measured Value = 7.080165 (C, atm, Hz, ...) 00:45:42 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 00:45:42 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888095 (C, atm, Hz, ...) 00:45:42 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.79 P3 = Right Coil Outgoing Side, Value = 27.69 P4 = Left Coil Middle, Value = 27.43 P5 = Ambient, Value = 21.77 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.43 P8 = Supply Pres(psi), Value = 94.93 P9 = Return Pres(psi), Value = 7.08 P10 = Flow Rate(gpm), Value = 0.89 00:45:42 Magnet system MAIN current ramping to 125.0000 A... 00:47:06 Magnet Current for MAIN, Imag = 124.9879 A Vtrans = 1.249878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:47:08 Main (V) Voltage Measurement, V = 4.455426 V 00:47:13 Temperature Measurement, Probe Number = 0, T = 25.790000 C 00:47:15 Temperature Measurement, Probe Number = 1, T = 27.493000 C 00:47:17 Temperature Measurement, Probe Number = 2, T = 27.363000 C 00:47:20 Temperature Measurement, Probe Number = 3, T = 21.765000 C 00:47:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317880 V 00:47:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317880 (V, A, ohm, ...), Measured Value = 28.303887 (C, atm, Hz, ...) 00:47:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.325520 V 00:47:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325520 (V, A, ohm, ...), Measured Value = 28.410004 (C, atm, Hz, ...) 00:47:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.257725 V 00:47:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.257725 (V, A, ohm, ...), Measured Value = 94.329345 (C, atm, Hz, ...) 00:47:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094486 V 00:47:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094486 (V, A, ohm, ...), Measured Value = 7.086457 (C, atm, Hz, ...) 00:47:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 00:47:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.881255 (C, atm, Hz, ...) 00:47:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 25.79 P3 = Right Coil Outgoing Side, Value = 27.49 P4 = Left Coil Middle, Value = 27.36 P5 = Ambient, Value = 21.77 P6 = Supply Temp(C), Value = 28.30 P7 = Return Temp(C), Value = 28.41 P8 = Supply Pres(psi), Value = 94.33 P9 = Return Pres(psi), Value = 7.09 P10 = Flow Rate(gpm), Value = 0.88 00:47:36 Magnet system MAIN current ramping to 0.0000 A... 00:49:00 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:49:03 Main (V) Voltage Measurement, V = 0.000003 V 00:49:08 Temperature Measurement, Probe Number = 0, T = 25.786000 C 00:49:10 Temperature Measurement, Probe Number = 1, T = 27.704000 C 00:49:12 Temperature Measurement, Probe Number = 2, T = 27.431000 C 00:49:14 Temperature Measurement, Probe Number = 3, T = 21.816000 C 00:49:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318226 V 00:49:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318226 (V, A, ohm, ...), Measured Value = 28.308696 (C, atm, Hz, ...) 00:49:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.327019 V 00:49:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.327019 (V, A, ohm, ...), Measured Value = 28.430814 (C, atm, Hz, ...) 00:49:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263758 V 00:49:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263758 (V, A, ohm, ...), Measured Value = 94.781858 (C, atm, Hz, ...) 00:49:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094648 V 00:49:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094648 (V, A, ohm, ...), Measured Value = 7.098570 (C, atm, Hz, ...) 00:49:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 00:49:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886066 (C, atm, Hz, ...) 00:49:30 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 25.79 P3 = Right Coil Outgoing Side, Value = 27.70 P4 = Left Coil Middle, Value = 27.43 P5 = Ambient, Value = 21.82 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.43 P8 = Supply Pres(psi), Value = 94.78 P9 = Return Pres(psi), Value = 7.10 P10 = Flow Rate(gpm), Value = 0.89 00:49:30 Magnet system MAIN current ramping to 75.0000 A... 00:50:26 Magnet Current for MAIN, Imag = 75.0195 A Vtrans = 0.750194 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:50:28 Main (V) Voltage Measurement, V = 2.668115 V 00:50:33 Temperature Measurement, Probe Number = 0, T = 25.786000 C 00:50:35 Temperature Measurement, Probe Number = 1, T = 27.450000 C 00:50:37 Temperature Measurement, Probe Number = 2, T = 27.179000 C 00:50:39 Temperature Measurement, Probe Number = 3, T = 21.709000 C 00:50:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318402 V 00:50:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318402 (V, A, ohm, ...), Measured Value = 28.311136 (C, atm, Hz, ...) 00:50:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.328964 V 00:50:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.328964 (V, A, ohm, ...), Measured Value = 28.457832 (C, atm, Hz, ...) 00:50:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.263974 V 00:50:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.263974 (V, A, ohm, ...), Measured Value = 94.798035 (C, atm, Hz, ...) 00:50:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.094830 V 00:50:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.094830 (V, A, ohm, ...), Measured Value = 7.112228 (C, atm, Hz, ...) 00:50:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000902 V 00:50:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000902 (V, A, ohm, ...), Measured Value = 0.902482 (C, atm, Hz, ...) 00:50:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 25.79 P3 = Right Coil Outgoing Side, Value = 27.45 P4 = Left Coil Middle, Value = 27.18 P5 = Ambient, Value = 21.71 P6 = Supply Temp(C), Value = 28.31 P7 = Return Temp(C), Value = 28.46 P8 = Supply Pres(psi), Value = 94.80 P9 = Return Pres(psi), Value = 7.11 P10 = Flow Rate(gpm), Value = 0.90 00:50:56 Magnetic Field Measurement Measuring the magnet strength... 00:50:56 Integrated Voltage Measurement... 00:50:58 Magnet Current for MAIN, Imag = 75.0196 A Vtrans = 0.750195 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402409 Vs 00:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399616 Vs 00:51:20 Magnet Current for MAIN, Imag = 75.0195 A Vtrans = 0.750194 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403923 Vs 00:51:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399463 Vs 00:51:40 Magnet Current for MAIN, Imag = 75.0197 A Vtrans = 0.750196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399270 Vs 00:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399216 Vs 00:52:01 Magnet Current for MAIN, Imag = 75.0193 A Vtrans = 0.750193 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000098 A 00:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405779 Vs 00:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402107 Vs 00:52:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401473 +- 0.000001683 Vs 00:52:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401473 +- 0.000001683 Vs BL = -0.16001636 +- 0.00001871 Tm 00:52:24 Position moved: 0.000000 m 00:52:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16002 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16002 0.00002 -0.16002 0.00000 00:52:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16002 0.00002 SL = -0.1600164 +- 0.0000187 Tm^2/m^n 00:52:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600164 +- 0.0000187 Tm^2/m^n 00:52:26 Position moved: 0.000000 m 00:52:29 Position moved: 0.000000 m 00:52:32 Magnet system MAIN current ramping to 0.0000 A...