SLAC Magnetic Measurements Date: 07-21-2025 Time: 12:02:37 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4565 Serial Number: Run Number: 4 Measurement Device: 10wire Operator: sda Comment: On the Curve step 5. Testing measurements at 87.5 amps and then at 75 A after stdz. Standardization for MAIN: 3 cycles from 0.0 A to 125.0 A to 0.0 A Test Currents for MAIN (A): 87.50 87.50 87.50 75.00 125.00 0.00 125.00 0.00 125.00 0.00 125.00 0.00 75.00 75.00 75.00 12:03:03 Position moved: 0.000000 m 12:03:13 Magnet Current for MAIN, Imag = -0.0009 A Vtrans = -0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:15 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:17 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:19 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:03:19 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0005 +- 0.0002 A 12:03:49 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0005175 A 12:03:49 Ambient Measurement Device(s) Being Used, type = None 12:03:50 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 12:03:51 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 12:03:51 Ambient Measurement Device(s) Being Used, type = HP34970 12:03:51 Magnet system MAIN current ramping to 125.0000 A... 12:05:04 Magnet Current for MAIN, Imag = 124.9907 A Vtrans = 1.249902 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:05:07 Main (V) Voltage Measurement, V = 4.459816 V 12:05:15 Temperature Measurement, Probe Number = 0, T = 26.376000 C 12:05:17 Temperature Measurement, Probe Number = 1, T = 27.698000 C 12:05:19 Temperature Measurement, Probe Number = 2, T = 28.055000 C 12:05:21 Temperature Measurement, Probe Number = 3, T = 23.836000 C 12:05:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341638 V 12:05:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341638 (V, A, ohm, ...), Measured Value = 28.633861 (C, atm, Hz, ...) 12:05:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.304628 V 12:05:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.304628 (V, A, ohm, ...), Measured Value = 28.119839 (C, atm, Hz, ...) 12:05:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.363427 V 12:05:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.363427 (V, A, ohm, ...), Measured Value = 102.257055 (C, atm, Hz, ...) 12:05:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085195 V 12:05:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085195 (V, A, ohm, ...), Measured Value = 6.389625 (C, atm, Hz, ...) 12:05:38 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000947 V 12:05:38 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000947 (V, A, ohm, ...), Measured Value = 0.946633 (C, atm, Hz, ...) 12:05:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.38 P3 = Right Coil Outgoing Side, Value = 27.70 P4 = Left Coil Middle, Value = 28.05 P5 = Ambient, Value = 23.84 P6 = Supply Temp(C), Value = 28.63 P7 = Return Temp(C), Value = 28.12 P8 = Supply Pres(psi), Value = 102.26 P9 = Return Pres(psi), Value = 6.39 P10 = Flow Rate(gpm), Value = 0.95 12:06:40 Magnet Current for MAIN, Imag = 124.9924 A Vtrans = 1.249919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:06:42 Main (V) Voltage Measurement, V = 4.466957 V 12:06:47 Temperature Measurement, Probe Number = 0, T = 26.322000 C 12:06:49 Temperature Measurement, Probe Number = 1, T = 28.279000 C 12:06:51 Temperature Measurement, Probe Number = 2, T = 28.461000 C 12:06:54 Temperature Measurement, Probe Number = 3, T = 23.839000 C 12:06:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.341931 V 12:06:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.341931 (V, A, ohm, ...), Measured Value = 28.637933 (C, atm, Hz, ...) 12:06:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.319644 V 12:06:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319644 (V, A, ohm, ...), Measured Value = 28.328394 (C, atm, Hz, ...) 12:07:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.364267 V 12:07:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.364267 (V, A, ohm, ...), Measured Value = 102.320025 (C, atm, Hz, ...) 12:07:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085112 V 12:07:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085112 (V, A, ohm, ...), Measured Value = 6.383423 (C, atm, Hz, ...) 12:07:10 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000937 V 12:07:10 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000937 (V, A, ohm, ...), Measured Value = 0.937378 (C, atm, Hz, ...) 12:07:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.32 P3 = Right Coil Outgoing Side, Value = 28.28 P4 = Left Coil Middle, Value = 28.46 P5 = Ambient, Value = 23.84 P6 = Supply Temp(C), Value = 28.64 P7 = Return Temp(C), Value = 28.33 P8 = Supply Pres(psi), Value = 102.32 P9 = Return Pres(psi), Value = 6.38 P10 = Flow Rate(gpm), Value = 0.94 12:08:12 Magnet Current for MAIN, Imag = 124.9923 A Vtrans = 1.249918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:08:14 Main (V) Voltage Measurement, V = 4.468020 V 12:08:19 Temperature Measurement, Probe Number = 0, T = 26.332000 C 12:08:22 Temperature Measurement, Probe Number = 1, T = 28.675000 C 12:08:24 Temperature Measurement, Probe Number = 2, T = 28.661000 C 12:08:26 Temperature Measurement, Probe Number = 3, T = 23.875000 C 12:08:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343065 V 12:08:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343065 (V, A, ohm, ...), Measured Value = 28.653685 (C, atm, Hz, ...) 12:08:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.354662 V 12:08:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354662 (V, A, ohm, ...), Measured Value = 28.814751 (C, atm, Hz, ...) 12:08:32 Sensor Voltage Measurement, Sensor Number = 2, V = 2.364562 V 12:08:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.364562 (V, A, ohm, ...), Measured Value = 102.342113 (C, atm, Hz, ...) 12:08:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085390 V 12:08:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085390 (V, A, ohm, ...), Measured Value = 6.404257 (C, atm, Hz, ...) 12:08:42 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000945 V 12:08:42 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000945 (V, A, ohm, ...), Measured Value = 0.944642 (C, atm, Hz, ...) 12:08:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.33 P3 = Right Coil Outgoing Side, Value = 28.68 P4 = Left Coil Middle, Value = 28.66 P5 = Ambient, Value = 23.88 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 28.81 P8 = Supply Pres(psi), Value = 102.34 P9 = Return Pres(psi), Value = 6.40 P10 = Flow Rate(gpm), Value = 0.94 12:09:45 Magnet Current for MAIN, Imag = 124.9931 A Vtrans = 1.249925 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:09:47 Main (V) Voltage Measurement, V = 4.467541 V 12:09:52 Temperature Measurement, Probe Number = 0, T = 26.345000 C 12:09:54 Temperature Measurement, Probe Number = 1, T = 28.944000 C 12:09:56 Temperature Measurement, Probe Number = 2, T = 28.719000 C 12:09:58 Temperature Measurement, Probe Number = 3, T = 23.887000 C 12:10:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343220 V 12:10:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343220 (V, A, ohm, ...), Measured Value = 28.655838 (C, atm, Hz, ...) 12:10:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.385226 V 12:10:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.385226 (V, A, ohm, ...), Measured Value = 29.239250 (C, atm, Hz, ...) 12:10:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.363083 V 12:10:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.363083 (V, A, ohm, ...), Measured Value = 102.231195 (C, atm, Hz, ...) 12:10:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085898 V 12:10:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085898 (V, A, ohm, ...), Measured Value = 6.442328 (C, atm, Hz, ...) 12:10:15 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000935 V 12:10:15 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000935 (V, A, ohm, ...), Measured Value = 0.935110 (C, atm, Hz, ...) 12:10:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.34 P3 = Right Coil Outgoing Side, Value = 28.94 P4 = Left Coil Middle, Value = 28.72 P5 = Ambient, Value = 23.89 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.24 P8 = Supply Pres(psi), Value = 102.23 P9 = Return Pres(psi), Value = 6.44 P10 = Flow Rate(gpm), Value = 0.94 12:11:17 Magnet Current for MAIN, Imag = 124.9927 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:11:19 Main (V) Voltage Measurement, V = 4.468095 V 12:11:24 Temperature Measurement, Probe Number = 0, T = 26.353000 C 12:11:26 Temperature Measurement, Probe Number = 1, T = 29.070000 C 12:11:28 Temperature Measurement, Probe Number = 2, T = 28.785000 C 12:11:30 Temperature Measurement, Probe Number = 3, T = 23.888000 C 12:11:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343631 V 12:11:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343631 (V, A, ohm, ...), Measured Value = 28.661542 (C, atm, Hz, ...) 12:11:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.405760 V 12:11:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.405760 (V, A, ohm, ...), Measured Value = 29.524443 (C, atm, Hz, ...) 12:11:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.370115 V 12:11:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.370115 (V, A, ohm, ...), Measured Value = 102.758588 (C, atm, Hz, ...) 12:11:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085913 V 12:11:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085913 (V, A, ohm, ...), Measured Value = 6.443490 (C, atm, Hz, ...) 12:11:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000943 V 12:11:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000943 (V, A, ohm, ...), Measured Value = 0.943415 (C, atm, Hz, ...) 12:11:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.35 P3 = Right Coil Outgoing Side, Value = 29.07 P4 = Left Coil Middle, Value = 28.79 P5 = Ambient, Value = 23.89 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.52 P8 = Supply Pres(psi), Value = 102.76 P9 = Return Pres(psi), Value = 6.44 P10 = Flow Rate(gpm), Value = 0.94 12:12:49 Magnet Current for MAIN, Imag = 124.9928 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:12:51 Main (V) Voltage Measurement, V = 4.468248 V 12:12:56 Temperature Measurement, Probe Number = 0, T = 26.366000 C 12:12:58 Temperature Measurement, Probe Number = 1, T = 29.076000 C 12:13:00 Temperature Measurement, Probe Number = 2, T = 28.804000 C 12:13:02 Temperature Measurement, Probe Number = 3, T = 23.916000 C 12:13:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.344030 V 12:13:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344030 (V, A, ohm, ...), Measured Value = 28.667086 (C, atm, Hz, ...) 12:13:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.418589 V 12:13:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.418589 (V, A, ohm, ...), Measured Value = 29.702628 (C, atm, Hz, ...) 12:13:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.362968 V 12:13:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.362968 (V, A, ohm, ...), Measured Value = 102.222570 (C, atm, Hz, ...) 12:13:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085845 V 12:13:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085845 (V, A, ohm, ...), Measured Value = 6.438352 (C, atm, Hz, ...) 12:13:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000935 V 12:13:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000935 (V, A, ohm, ...), Measured Value = 0.935180 (C, atm, Hz, ...) 12:13:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.37 P3 = Right Coil Outgoing Side, Value = 29.08 P4 = Left Coil Middle, Value = 28.80 P5 = Ambient, Value = 23.92 P6 = Supply Temp(C), Value = 28.67 P7 = Return Temp(C), Value = 29.70 P8 = Supply Pres(psi), Value = 102.22 P9 = Return Pres(psi), Value = 6.44 P10 = Flow Rate(gpm), Value = 0.94 12:14:21 Magnet Current for MAIN, Imag = 124.9918 A Vtrans = 1.249912 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:14:23 Main (V) Voltage Measurement, V = 4.468258 V 12:14:28 Temperature Measurement, Probe Number = 0, T = 26.375000 C 12:14:31 Temperature Measurement, Probe Number = 1, T = 29.153000 C 12:14:33 Temperature Measurement, Probe Number = 2, T = 28.792000 C 12:14:35 Temperature Measurement, Probe Number = 3, T = 23.929000 C 12:14:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343647 V 12:14:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343647 (V, A, ohm, ...), Measured Value = 28.661757 (C, atm, Hz, ...) 12:14:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.427278 V 12:14:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.427278 (V, A, ohm, ...), Measured Value = 29.823311 (C, atm, Hz, ...) 12:14:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.380169 V 12:14:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.380169 (V, A, ohm, ...), Measured Value = 103.512675 (C, atm, Hz, ...) 12:14:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085713 V 12:14:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085713 (V, A, ohm, ...), Measured Value = 6.428475 (C, atm, Hz, ...) 12:14:51 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000940 V 12:14:51 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000940 (V, A, ohm, ...), Measured Value = 0.940101 (C, atm, Hz, ...) 12:14:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.38 P3 = Right Coil Outgoing Side, Value = 29.15 P4 = Left Coil Middle, Value = 28.79 P5 = Ambient, Value = 23.93 P6 = Supply Temp(C), Value = 28.66 P7 = Return Temp(C), Value = 29.82 P8 = Supply Pres(psi), Value = 103.51 P9 = Return Pres(psi), Value = 6.43 P10 = Flow Rate(gpm), Value = 0.94 12:15:54 Magnet Current for MAIN, Imag = 124.9915 A Vtrans = 1.249910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:15:56 Main (V) Voltage Measurement, V = 4.467971 V 12:16:01 Temperature Measurement, Probe Number = 0, T = 26.390000 C 12:16:03 Temperature Measurement, Probe Number = 1, T = 29.161000 C 12:16:05 Temperature Measurement, Probe Number = 2, T = 28.827000 C 12:16:07 Temperature Measurement, Probe Number = 3, T = 23.932000 C 12:16:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343092 V 12:16:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343092 (V, A, ohm, ...), Measured Value = 28.654061 (C, atm, Hz, ...) 12:16:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.432682 V 12:16:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.432682 (V, A, ohm, ...), Measured Value = 29.898354 (C, atm, Hz, ...) 12:16:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.367939 V 12:16:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.367939 (V, A, ohm, ...), Measured Value = 102.595448 (C, atm, Hz, ...) 12:16:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085894 V 12:16:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085894 (V, A, ohm, ...), Measured Value = 6.442035 (C, atm, Hz, ...) 12:16:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000935 V 12:16:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000935 (V, A, ohm, ...), Measured Value = 0.935058 (C, atm, Hz, ...) 12:16:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.39 P3 = Right Coil Outgoing Side, Value = 29.16 P4 = Left Coil Middle, Value = 28.83 P5 = Ambient, Value = 23.93 P6 = Supply Temp(C), Value = 28.65 P7 = Return Temp(C), Value = 29.90 P8 = Supply Pres(psi), Value = 102.60 P9 = Return Pres(psi), Value = 6.44 P10 = Flow Rate(gpm), Value = 0.94 12:16:24 Magnet system MAIN current ramping to 0.0000 A... 12:17:45 Magnet system MAIN current ramping to 125.0000 A... 12:19:07 Magnet system MAIN current ramping to 0.0000 A... 12:20:29 Magnet system MAIN current ramping to 125.0000 A... 12:21:51 Magnet system MAIN current ramping to 0.0000 A... 12:23:13 Magnet system MAIN current ramping to 125.0000 A... 12:24:34 Magnet system MAIN current ramping to 0.0000 A... 12:26:00 Position moved: 0.000000 m 12:26:03 Magnet system MAIN current ramping to 87.5000 A... 12:27:05 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:27:08 Main (V) Voltage Measurement, V = 3.117010 V 12:27:13 Temperature Measurement, Probe Number = 0, T = 26.450000 C 12:27:15 Temperature Measurement, Probe Number = 1, T = 28.249000 C 12:27:17 Temperature Measurement, Probe Number = 2, T = 28.266000 C 12:27:19 Temperature Measurement, Probe Number = 3, T = 24.025000 C 12:27:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.343948 V 12:27:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.343948 (V, A, ohm, ...), Measured Value = 28.665938 (C, atm, Hz, ...) 12:27:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374753 V 12:27:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374753 (V, A, ohm, ...), Measured Value = 29.093792 (C, atm, Hz, ...) 12:27:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.366547 V 12:27:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.366547 (V, A, ohm, ...), Measured Value = 102.491017 (C, atm, Hz, ...) 12:27:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085217 V 12:27:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085217 (V, A, ohm, ...), Measured Value = 6.391275 (C, atm, Hz, ...) 12:27:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000943 V 12:27:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000943 (V, A, ohm, ...), Measured Value = 0.942972 (C, atm, Hz, ...) 12:27:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.45 P3 = Right Coil Outgoing Side, Value = 28.25 P4 = Left Coil Middle, Value = 28.27 P5 = Ambient, Value = 24.02 P6 = Supply Temp(C), Value = 28.67 P7 = Return Temp(C), Value = 29.09 P8 = Supply Pres(psi), Value = 102.49 P9 = Return Pres(psi), Value = 6.39 P10 = Flow Rate(gpm), Value = 0.94 12:27:35 Magnetic Field Measurement Measuring the magnet strength... 12:27:35 Integrated Voltage Measurement... 12:27:38 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:27:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773650 Vs 12:27:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766110 Vs 12:28:00 Magnet Current for MAIN, Imag = 87.4699 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777963 Vs 12:28:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768317 Vs 12:28:21 Magnet Current for MAIN, Imag = 87.4705 A Vtrans = 0.874700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775863 Vs 12:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768636 Vs 12:28:41 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:28:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776561 Vs 12:29:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016769172 Vs 12:29:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772034 +- 0.000001285 Vs 12:29:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016772034 +- 0.000001285 Vs BL = -0.18635593 +- 0.00001427 Tm 12:29:04 Position moved: 0.000000 m 12:29:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18636 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18636 0.00001 -0.18636 0.00000 12:29:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18636 0.00001 SL = -0.1863559 +- 0.0000143 Tm^2/m^n 12:29:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863559 +- 0.0000143 Tm^2/m^n 12:29:07 Position moved: 0.000000 m 12:29:07 Magnet system MAIN current ramping to 87.5000 A... 12:29:20 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:29:22 Main (V) Voltage Measurement, V = 3.119600 V 12:29:27 Temperature Measurement, Probe Number = 0, T = 26.456000 C 12:29:29 Temperature Measurement, Probe Number = 1, T = 28.320000 C 12:29:31 Temperature Measurement, Probe Number = 2, T = 28.382000 C 12:29:33 Temperature Measurement, Probe Number = 3, T = 24.016000 C 12:29:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.344480 V 12:29:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344480 (V, A, ohm, ...), Measured Value = 28.673329 (C, atm, Hz, ...) 12:29:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365634 V 12:29:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365634 (V, A, ohm, ...), Measured Value = 28.967135 (C, atm, Hz, ...) 12:29:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.363614 V 12:29:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.363614 (V, A, ohm, ...), Measured Value = 102.271012 (C, atm, Hz, ...) 12:29:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085439 V 12:29:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085439 (V, A, ohm, ...), Measured Value = 6.407933 (C, atm, Hz, ...) 12:29:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000938 V 12:29:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000938 (V, A, ohm, ...), Measured Value = 0.937681 (C, atm, Hz, ...) 12:29:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.46 P3 = Right Coil Outgoing Side, Value = 28.32 P4 = Left Coil Middle, Value = 28.38 P5 = Ambient, Value = 24.02 P6 = Supply Temp(C), Value = 28.67 P7 = Return Temp(C), Value = 28.97 P8 = Supply Pres(psi), Value = 102.27 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.94 12:29:50 Magnetic Field Measurement Measuring the magnet strength... 12:29:50 Integrated Voltage Measurement... 12:29:52 Magnet Current for MAIN, Imag = 87.4695 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:30:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777917 Vs 12:30:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016766954 Vs 12:30:14 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:30:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776948 Vs 12:30:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768622 Vs 12:30:35 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:30:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776523 Vs 12:30:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016767996 Vs 12:30:56 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:31:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776268 Vs 12:31:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016769216 Vs 12:31:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772556 +- 0.000000218 Vs 12:31:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016772556 +- 0.000000218 Vs BL = -0.18636173 +- 0.00000242 Tm 12:31:18 Position moved: 0.000000 m 12:31:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18636 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18636 0.00000 -0.18636 0.00000 12:31:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18636 0.00000 SL = -0.1863617 +- 0.0000024 Tm^2/m^n 12:31:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863617 +- 0.0000024 Tm^2/m^n 12:31:21 Position moved: 0.000000 m 12:31:21 Magnet system MAIN current ramping to 87.5000 A... 12:31:34 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:31:36 Main (V) Voltage Measurement, V = 3.119753 V 12:31:41 Temperature Measurement, Probe Number = 0, T = 26.474000 C 12:31:43 Temperature Measurement, Probe Number = 1, T = 28.430000 C 12:31:46 Temperature Measurement, Probe Number = 2, T = 28.424000 C 12:31:48 Temperature Measurement, Probe Number = 3, T = 24.069000 C 12:31:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345373 V 12:31:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345373 (V, A, ohm, ...), Measured Value = 28.685743 (C, atm, Hz, ...) 12:31:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.370660 V 12:31:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.370660 (V, A, ohm, ...), Measured Value = 29.036939 (C, atm, Hz, ...) 12:31:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.379855 V 12:31:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.379855 (V, A, ohm, ...), Measured Value = 103.489132 (C, atm, Hz, ...) 12:31:56 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085452 V 12:31:56 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085452 (V, A, ohm, ...), Measured Value = 6.408907 (C, atm, Hz, ...) 12:32:04 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000933 V 12:32:04 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000933 (V, A, ohm, ...), Measured Value = 0.932752 (C, atm, Hz, ...) 12:32:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.47 P3 = Right Coil Outgoing Side, Value = 28.43 P4 = Left Coil Middle, Value = 28.42 P5 = Ambient, Value = 24.07 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.04 P8 = Supply Pres(psi), Value = 103.49 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.93 12:32:04 Magnetic Field Measurement Measuring the magnet strength... 12:32:04 Integrated Voltage Measurement... 12:32:06 Magnet Current for MAIN, Imag = 87.4699 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:32:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776805 Vs 12:32:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768201 Vs 12:32:28 Magnet Current for MAIN, Imag = 87.4706 A Vtrans = 0.874701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775946 Vs 12:32:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768006 Vs 12:32:49 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:32:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775674 Vs 12:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016769262 Vs 12:33:10 Magnet Current for MAIN, Imag = 87.4693 A Vtrans = 0.874688 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:33:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776329 Vs 12:33:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016767786 Vs 12:33:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016772251 +- 0.000000237 Vs 12:33:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016772251 +- 0.000000237 Vs BL = -0.18635835 +- 0.00000263 Tm 12:33:32 Position moved: 0.000000 m 12:33:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18636 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18636 0.00000 -0.18636 0.00000 12:33:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18636 0.00000 SL = -0.1863583 +- 0.0000026 Tm^2/m^n 12:33:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863583 +- 0.0000026 Tm^2/m^n 12:33:35 Position moved: 0.000000 m 12:33:35 Magnet system MAIN current ramping to 75.0000 A... 12:33:55 Magnet Current for MAIN, Imag = 75.0236 A Vtrans = 0.750231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:33:57 Main (V) Voltage Measurement, V = 2.675501 V 12:34:02 Temperature Measurement, Probe Number = 0, T = 26.481000 C 12:34:05 Temperature Measurement, Probe Number = 1, T = 28.453000 C 12:34:07 Temperature Measurement, Probe Number = 2, T = 28.443000 C 12:34:09 Temperature Measurement, Probe Number = 3, T = 24.051000 C 12:34:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345420 V 12:34:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345420 (V, A, ohm, ...), Measured Value = 28.686389 (C, atm, Hz, ...) 12:34:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.375452 V 12:34:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375452 (V, A, ohm, ...), Measured Value = 29.103497 (C, atm, Hz, ...) 12:34:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.370108 V 12:34:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.370108 (V, A, ohm, ...), Measured Value = 102.758107 (C, atm, Hz, ...) 12:34:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085619 V 12:34:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085619 (V, A, ohm, ...), Measured Value = 6.421402 (C, atm, Hz, ...) 12:34:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000938 V 12:34:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000938 (V, A, ohm, ...), Measured Value = 0.937937 (C, atm, Hz, ...) 12:34:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.48 P3 = Right Coil Outgoing Side, Value = 28.45 P4 = Left Coil Middle, Value = 28.44 P5 = Ambient, Value = 24.05 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.10 P8 = Supply Pres(psi), Value = 102.76 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.94 12:34:25 Magnet system MAIN current ramping to 125.0000 A... 12:35:07 Magnet Current for MAIN, Imag = 124.9928 A Vtrans = 1.249923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:35:09 Main (V) Voltage Measurement, V = 4.461920 V 12:35:14 Temperature Measurement, Probe Number = 0, T = 26.488000 C 12:35:16 Temperature Measurement, Probe Number = 1, T = 28.470000 C 12:35:19 Temperature Measurement, Probe Number = 2, T = 28.468000 C 12:35:21 Temperature Measurement, Probe Number = 3, T = 24.056000 C 12:35:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345677 V 12:35:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345677 (V, A, ohm, ...), Measured Value = 28.689960 (C, atm, Hz, ...) 12:35:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.376679 V 12:35:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376679 (V, A, ohm, ...), Measured Value = 29.120540 (C, atm, Hz, ...) 12:35:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.381486 V 12:35:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.381486 (V, A, ohm, ...), Measured Value = 103.611487 (C, atm, Hz, ...) 12:35:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085637 V 12:35:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085637 (V, A, ohm, ...), Measured Value = 6.422760 (C, atm, Hz, ...) 12:35:37 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000943 V 12:35:37 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000943 (V, A, ohm, ...), Measured Value = 0.942709 (C, atm, Hz, ...) 12:35:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.49 P3 = Right Coil Outgoing Side, Value = 28.47 P4 = Left Coil Middle, Value = 28.47 P5 = Ambient, Value = 24.06 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.12 P8 = Supply Pres(psi), Value = 103.61 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.94 12:35:37 Magnet system MAIN current ramping to 0.0000 A... 12:37:01 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:37:03 Main (V) Voltage Measurement, V = -0.000003 V 12:37:08 Temperature Measurement, Probe Number = 0, T = 26.492000 C 12:37:11 Temperature Measurement, Probe Number = 1, T = 28.557000 C 12:37:13 Temperature Measurement, Probe Number = 2, T = 28.465000 C 12:37:15 Temperature Measurement, Probe Number = 3, T = 24.063000 C 12:37:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345460 V 12:37:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345460 (V, A, ohm, ...), Measured Value = 28.686946 (C, atm, Hz, ...) 12:37:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.382521 V 12:37:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.382521 (V, A, ohm, ...), Measured Value = 29.201683 (C, atm, Hz, ...) 12:37:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.375089 V 12:37:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.375089 (V, A, ohm, ...), Measured Value = 103.131660 (C, atm, Hz, ...) 12:37:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085541 V 12:37:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085541 (V, A, ohm, ...), Measured Value = 6.415590 (C, atm, Hz, ...) 12:37:31 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000954 V 12:37:31 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000954 (V, A, ohm, ...), Measured Value = 0.954354 (C, atm, Hz, ...) 12:37:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.49 P3 = Right Coil Outgoing Side, Value = 28.56 P4 = Left Coil Middle, Value = 28.46 P5 = Ambient, Value = 24.06 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.20 P8 = Supply Pres(psi), Value = 103.13 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.95 12:37:31 Magnet system MAIN current ramping to 125.0000 A... 12:38:55 Magnet Current for MAIN, Imag = 124.9929 A Vtrans = 1.249924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:38:57 Main (V) Voltage Measurement, V = 4.462584 V 12:39:02 Temperature Measurement, Probe Number = 0, T = 26.503000 C 12:39:05 Temperature Measurement, Probe Number = 1, T = 28.349000 C 12:39:07 Temperature Measurement, Probe Number = 2, T = 28.383000 C 12:39:09 Temperature Measurement, Probe Number = 3, T = 24.084000 C 12:39:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345407 V 12:39:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345407 (V, A, ohm, ...), Measured Value = 28.686210 (C, atm, Hz, ...) 12:39:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.377825 V 12:39:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377825 (V, A, ohm, ...), Measured Value = 29.136453 (C, atm, Hz, ...) 12:39:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.371086 V 12:39:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.371086 (V, A, ohm, ...), Measured Value = 102.831443 (C, atm, Hz, ...) 12:39:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085573 V 12:39:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085573 (V, A, ohm, ...), Measured Value = 6.418012 (C, atm, Hz, ...) 12:39:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000948 V 12:39:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000948 (V, A, ohm, ...), Measured Value = 0.947501 (C, atm, Hz, ...) 12:39:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.50 P3 = Right Coil Outgoing Side, Value = 28.35 P4 = Left Coil Middle, Value = 28.38 P5 = Ambient, Value = 24.08 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.14 P8 = Supply Pres(psi), Value = 102.83 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.95 12:39:25 Magnet system MAIN current ramping to 0.0000 A... 12:40:50 Magnet Current for MAIN, Imag = 0.0004 A Vtrans = -0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:40:52 Main (V) Voltage Measurement, V = 0.000000 V 12:40:57 Temperature Measurement, Probe Number = 0, T = 26.522000 C 12:41:00 Temperature Measurement, Probe Number = 1, T = 28.511000 C 12:41:02 Temperature Measurement, Probe Number = 2, T = 28.434000 C 12:41:04 Temperature Measurement, Probe Number = 3, T = 24.112000 C 12:41:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345913 V 12:41:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345913 (V, A, ohm, ...), Measured Value = 28.693242 (C, atm, Hz, ...) 12:41:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.378346 V 12:41:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378346 (V, A, ohm, ...), Measured Value = 29.143700 (C, atm, Hz, ...) 12:41:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.371276 V 12:41:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.371276 (V, A, ohm, ...), Measured Value = 102.845677 (C, atm, Hz, ...) 12:41:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085572 V 12:41:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085572 (V, A, ohm, ...), Measured Value = 6.417915 (C, atm, Hz, ...) 12:41:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000925 V 12:41:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000925 (V, A, ohm, ...), Measured Value = 0.925220 (C, atm, Hz, ...) 12:41:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.52 P3 = Right Coil Outgoing Side, Value = 28.51 P4 = Left Coil Middle, Value = 28.43 P5 = Ambient, Value = 24.11 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.14 P8 = Supply Pres(psi), Value = 102.85 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.93 12:41:20 Magnet system MAIN current ramping to 125.0000 A... 12:42:44 Magnet Current for MAIN, Imag = 124.9931 A Vtrans = 1.249925 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:42:46 Main (V) Voltage Measurement, V = 4.462740 V 12:42:51 Temperature Measurement, Probe Number = 0, T = 26.527000 C 12:42:54 Temperature Measurement, Probe Number = 1, T = 28.302000 C 12:42:56 Temperature Measurement, Probe Number = 2, T = 28.364000 C 12:42:58 Temperature Measurement, Probe Number = 3, T = 24.110000 C 12:43:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345833 V 12:43:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345833 (V, A, ohm, ...), Measured Value = 28.692131 (C, atm, Hz, ...) 12:43:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.376136 V 12:43:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376136 (V, A, ohm, ...), Measured Value = 29.113006 (C, atm, Hz, ...) 12:43:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.371052 V 12:43:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.371052 (V, A, ohm, ...), Measured Value = 102.828923 (C, atm, Hz, ...) 12:43:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085455 V 12:43:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085455 (V, A, ohm, ...), Measured Value = 6.409095 (C, atm, Hz, ...) 12:43:14 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000930 V 12:43:14 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000930 (V, A, ohm, ...), Measured Value = 0.930348 (C, atm, Hz, ...) 12:43:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.30 P4 = Left Coil Middle, Value = 28.36 P5 = Ambient, Value = 24.11 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.11 P8 = Supply Pres(psi), Value = 102.83 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.93 12:43:14 Magnet system MAIN current ramping to 0.0000 A... 12:44:38 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:44:40 Main (V) Voltage Measurement, V = -0.000006 V 12:44:45 Temperature Measurement, Probe Number = 0, T = 26.533000 C 12:44:47 Temperature Measurement, Probe Number = 1, T = 28.547000 C 12:44:49 Temperature Measurement, Probe Number = 2, T = 28.476000 C 12:44:51 Temperature Measurement, Probe Number = 3, T = 24.139000 C 12:44:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.346081 V 12:44:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346081 (V, A, ohm, ...), Measured Value = 28.695575 (C, atm, Hz, ...) 12:44:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.377358 V 12:44:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377358 (V, A, ohm, ...), Measured Value = 29.129976 (C, atm, Hz, ...) 12:44:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.368084 V 12:44:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.368084 (V, A, ohm, ...), Measured Value = 102.606300 (C, atm, Hz, ...) 12:45:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085593 V 12:45:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085593 (V, A, ohm, ...), Measured Value = 6.419460 (C, atm, Hz, ...) 12:45:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000945 V 12:45:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000945 (V, A, ohm, ...), Measured Value = 0.945257 (C, atm, Hz, ...) 12:45:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.53 P3 = Right Coil Outgoing Side, Value = 28.55 P4 = Left Coil Middle, Value = 28.48 P5 = Ambient, Value = 24.14 P6 = Supply Temp(C), Value = 28.70 P7 = Return Temp(C), Value = 29.13 P8 = Supply Pres(psi), Value = 102.61 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.95 12:45:08 Magnet system MAIN current ramping to 125.0000 A... 12:46:32 Magnet Current for MAIN, Imag = 124.9923 A Vtrans = 1.249918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:46:34 Main (V) Voltage Measurement, V = 4.462941 V 12:46:39 Temperature Measurement, Probe Number = 0, T = 26.541000 C 12:46:41 Temperature Measurement, Probe Number = 1, T = 28.366000 C 12:46:44 Temperature Measurement, Probe Number = 2, T = 28.397000 C 12:46:46 Temperature Measurement, Probe Number = 3, T = 24.143000 C 12:46:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.345911 V 12:46:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.345911 (V, A, ohm, ...), Measured Value = 28.693207 (C, atm, Hz, ...) 12:46:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.376040 V 12:46:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376040 (V, A, ohm, ...), Measured Value = 29.111660 (C, atm, Hz, ...) 12:46:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.367699 V 12:46:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.367699 (V, A, ohm, ...), Measured Value = 102.577432 (C, atm, Hz, ...) 12:46:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085461 V 12:46:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085461 (V, A, ohm, ...), Measured Value = 6.409583 (C, atm, Hz, ...) 12:47:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000958 V 12:47:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000958 (V, A, ohm, ...), Measured Value = 0.957541 (C, atm, Hz, ...) 12:47:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.54 P3 = Right Coil Outgoing Side, Value = 28.37 P4 = Left Coil Middle, Value = 28.40 P5 = Ambient, Value = 24.14 P6 = Supply Temp(C), Value = 28.69 P7 = Return Temp(C), Value = 29.11 P8 = Supply Pres(psi), Value = 102.58 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.96 12:47:02 Magnet system MAIN current ramping to 0.0000 A... 12:48:25 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:48:28 Main (V) Voltage Measurement, V = -0.000003 V 12:48:33 Temperature Measurement, Probe Number = 0, T = 26.554000 C 12:48:35 Temperature Measurement, Probe Number = 1, T = 28.543000 C 12:48:37 Temperature Measurement, Probe Number = 2, T = 28.482000 C 12:48:39 Temperature Measurement, Probe Number = 3, T = 24.166000 C 12:48:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.346562 V 12:48:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346562 (V, A, ohm, ...), Measured Value = 28.702249 (C, atm, Hz, ...) 12:48:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.377775 V 12:48:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377775 (V, A, ohm, ...), Measured Value = 29.135771 (C, atm, Hz, ...) 12:48:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.391119 V 12:48:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.391119 (V, A, ohm, ...), Measured Value = 104.333902 (C, atm, Hz, ...) 12:48:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085611 V 12:48:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085611 (V, A, ohm, ...), Measured Value = 6.420818 (C, atm, Hz, ...) 12:48:55 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000940 V 12:48:55 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000940 (V, A, ohm, ...), Measured Value = 0.940063 (C, atm, Hz, ...) 12:48:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.55 P3 = Right Coil Outgoing Side, Value = 28.54 P4 = Left Coil Middle, Value = 28.48 P5 = Ambient, Value = 24.17 P6 = Supply Temp(C), Value = 28.70 P7 = Return Temp(C), Value = 29.14 P8 = Supply Pres(psi), Value = 104.33 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.94 12:48:55 Magnet system MAIN current ramping to 75.0000 A... 12:49:51 Magnet Current for MAIN, Imag = 75.0225 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:49:53 Main (V) Voltage Measurement, V = 2.672673 V 12:49:58 Temperature Measurement, Probe Number = 0, T = 26.557000 C 12:50:00 Temperature Measurement, Probe Number = 1, T = 28.294000 C 12:50:02 Temperature Measurement, Probe Number = 2, T = 28.286000 C 12:50:04 Temperature Measurement, Probe Number = 3, T = 24.149000 C 12:50:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.346943 V 12:50:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346943 (V, A, ohm, ...), Measured Value = 28.707540 (C, atm, Hz, ...) 12:50:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.379933 V 12:50:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.379933 (V, A, ohm, ...), Measured Value = 29.165731 (C, atm, Hz, ...) 12:50:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.372677 V 12:50:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.372677 (V, A, ohm, ...), Measured Value = 102.950790 (C, atm, Hz, ...) 12:50:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085399 V 12:50:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085399 (V, A, ohm, ...), Measured Value = 6.404933 (C, atm, Hz, ...) 12:50:21 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000940 V 12:50:21 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000940 (V, A, ohm, ...), Measured Value = 0.940310 (C, atm, Hz, ...) 12:50:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.29 P4 = Left Coil Middle, Value = 28.29 P5 = Ambient, Value = 24.15 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 29.17 P8 = Supply Pres(psi), Value = 102.95 P9 = Return Pres(psi), Value = 6.40 P10 = Flow Rate(gpm), Value = 0.94 12:50:21 Magnetic Field Measurement Measuring the magnet strength... 12:50:21 Integrated Voltage Measurement... 12:50:23 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:50:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402609 Vs 12:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014394645 Vs 12:50:45 Magnet Current for MAIN, Imag = 75.0229 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:50:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404044 Vs 12:51:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397013 Vs 12:51:06 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:51:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404168 Vs 12:51:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396331 Vs 12:51:26 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:51:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402285 Vs 12:51:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395765 Vs 12:51:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399608 +- 0.000000800 Vs 12:51:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014399608 +- 0.000000800 Vs BL = -0.15999564 +- 0.00000889 Tm 12:51:49 Position moved: 0.000000 m 12:51:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16000 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16000 0.00001 -0.16000 0.00000 12:51:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16000 0.00001 SL = -0.1599956 +- 0.0000089 Tm^2/m^n 12:51:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599956 +- 0.0000089 Tm^2/m^n 12:51:52 Position moved: 0.000000 m 12:51:52 Magnet system MAIN current ramping to 75.0000 A... 12:52:05 Magnet Current for MAIN, Imag = 75.0220 A Vtrans = 0.750215 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:52:07 Main (V) Voltage Measurement, V = 2.674359 V 12:52:12 Temperature Measurement, Probe Number = 0, T = 26.562000 C 12:52:14 Temperature Measurement, Probe Number = 1, T = 28.275000 C 12:52:17 Temperature Measurement, Probe Number = 2, T = 28.341000 C 12:52:19 Temperature Measurement, Probe Number = 3, T = 24.187000 C 12:52:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347075 V 12:52:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347075 (V, A, ohm, ...), Measured Value = 28.709371 (C, atm, Hz, ...) 12:52:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.365142 V 12:52:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.365142 (V, A, ohm, ...), Measured Value = 28.960299 (C, atm, Hz, ...) 12:52:25 Sensor Voltage Measurement, Sensor Number = 2, V = 2.371268 V 12:52:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.371268 (V, A, ohm, ...), Measured Value = 102.845100 (C, atm, Hz, ...) 12:52:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085438 V 12:52:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085438 (V, A, ohm, ...), Measured Value = 6.407835 (C, atm, Hz, ...) 12:52:35 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000938 V 12:52:35 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000938 (V, A, ohm, ...), Measured Value = 0.938298 (C, atm, Hz, ...) 12:52:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.56 P3 = Right Coil Outgoing Side, Value = 28.27 P4 = Left Coil Middle, Value = 28.34 P5 = Ambient, Value = 24.19 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 28.96 P8 = Supply Pres(psi), Value = 102.85 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.94 12:52:35 Magnetic Field Measurement Measuring the magnet strength... 12:52:35 Integrated Voltage Measurement... 12:52:37 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:52:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404671 Vs 12:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396123 Vs 12:52:59 Magnet Current for MAIN, Imag = 75.0235 A Vtrans = 0.750230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:53:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406525 Vs 12:53:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014394885 Vs 12:53:20 Magnet Current for MAIN, Imag = 75.0222 A Vtrans = 0.750217 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:53:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405175 Vs 12:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014394692 Vs 12:53:41 Magnet Current for MAIN, Imag = 75.0223 A Vtrans = 0.750218 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:53:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406260 Vs 12:53:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396269 Vs 12:53:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400575 +- 0.000000484 Vs 12:53:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014400575 +- 0.000000484 Vs BL = -0.16000639 +- 0.00000537 Tm 12:54:03 Position moved: 0.000000 m 12:54:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00001 -0.16001 0.00000 12:54:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00001 SL = -0.1600064 +- 0.0000054 Tm^2/m^n 12:54:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600064 +- 0.0000054 Tm^2/m^n 12:54:06 Position moved: 0.000000 m 12:54:06 Magnet system MAIN current ramping to 75.0000 A... 12:54:19 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:54:22 Main (V) Voltage Measurement, V = 2.674412 V 12:54:27 Temperature Measurement, Probe Number = 0, T = 26.581000 C 12:54:29 Temperature Measurement, Probe Number = 1, T = 28.248000 C 12:54:31 Temperature Measurement, Probe Number = 2, T = 28.341000 C 12:54:33 Temperature Measurement, Probe Number = 3, T = 24.216000 C 12:54:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347017 V 12:54:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347017 (V, A, ohm, ...), Measured Value = 28.708562 (C, atm, Hz, ...) 12:54:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363938 V 12:54:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363938 (V, A, ohm, ...), Measured Value = 28.943579 (C, atm, Hz, ...) 12:54:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.372477 V 12:54:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.372477 (V, A, ohm, ...), Measured Value = 102.935775 (C, atm, Hz, ...) 12:54:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085411 V 12:54:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085411 (V, A, ohm, ...), Measured Value = 6.405802 (C, atm, Hz, ...) 12:54:49 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000932 V 12:54:49 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000932 (V, A, ohm, ...), Measured Value = 0.932392 (C, atm, Hz, ...) 12:54:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.58 P3 = Right Coil Outgoing Side, Value = 28.25 P4 = Left Coil Middle, Value = 28.34 P5 = Ambient, Value = 24.22 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 28.94 P8 = Supply Pres(psi), Value = 102.94 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.93 12:54:49 Magnetic Field Measurement Measuring the magnet strength... 12:54:49 Integrated Voltage Measurement... 12:54:52 Magnet Current for MAIN, Imag = 75.0229 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:55:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402368 Vs 12:55:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395290 Vs 12:55:13 Magnet Current for MAIN, Imag = 75.0231 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:55:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401155 Vs 12:55:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397072 Vs 12:55:34 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:55:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401887 Vs 12:55:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396921 Vs 12:55:55 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 12:56:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404589 Vs 12:56:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396171 Vs 12:56:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014399432 +- 0.000000584 Vs 12:56:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014399432 +- 0.000000584 Vs BL = -0.15999369 +- 0.00000649 Tm 12:56:18 Position moved: 0.000000 m 12:56:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.15999 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.15999 0.00001 -0.15999 0.00000 12:56:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.15999 0.00001 SL = -0.1599937 +- 0.0000065 Tm^2/m^n 12:56:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1599937 +- 0.0000065 Tm^2/m^n 12:56:21 Position moved: 0.000000 m 12:56:21 Magnet system MAIN current ramping to 125.0000 A... 12:57:00 Magnet system MAIN current ramping to 0.0000 A... 12:58:21 Magnet system MAIN current ramping to 125.0000 A... 12:59:43 Magnet system MAIN current ramping to 0.0000 A... 13:01:06 Magnet system MAIN current ramping to 125.0000 A... 13:02:27 Magnet system MAIN current ramping to 0.0000 A... 13:03:52 Position moved: 0.000000 m 13:03:55 Magnet system MAIN current ramping to 87.5000 A... 13:04:58 Magnet Current for MAIN, Imag = 87.4706 A Vtrans = 0.874701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:05:00 Main (V) Voltage Measurement, V = 3.117555 V 13:05:05 Temperature Measurement, Probe Number = 0, T = 26.627000 C 13:05:07 Temperature Measurement, Probe Number = 1, T = 28.290000 C 13:05:09 Temperature Measurement, Probe Number = 2, T = 28.326000 C 13:05:11 Temperature Measurement, Probe Number = 3, T = 24.235000 C 13:05:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.346954 V 13:05:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346954 (V, A, ohm, ...), Measured Value = 28.707701 (C, atm, Hz, ...) 13:05:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374110 V 13:05:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374110 (V, A, ohm, ...), Measured Value = 29.084857 (C, atm, Hz, ...) 13:05:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.368381 V 13:05:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.368381 (V, A, ohm, ...), Measured Value = 102.628583 (C, atm, Hz, ...) 13:05:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085652 V 13:05:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085652 (V, A, ohm, ...), Measured Value = 6.423923 (C, atm, Hz, ...) 13:05:28 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000944 V 13:05:28 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000944 (V, A, ohm, ...), Measured Value = 0.944377 (C, atm, Hz, ...) 13:05:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.63 P3 = Right Coil Outgoing Side, Value = 28.29 P4 = Left Coil Middle, Value = 28.33 P5 = Ambient, Value = 24.23 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 29.08 P8 = Supply Pres(psi), Value = 102.63 P9 = Return Pres(psi), Value = 6.42 P10 = Flow Rate(gpm), Value = 0.94 13:05:28 Magnetic Field Measurement Measuring the magnet strength... 13:05:28 Integrated Voltage Measurement... 13:05:30 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:05:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774587 Vs 13:05:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770017 Vs 13:05:52 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:06:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775798 Vs 13:06:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770831 Vs 13:06:13 Magnet Current for MAIN, Imag = 87.4699 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777310 Vs 13:06:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770433 Vs 13:06:34 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:06:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777700 Vs 13:06:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771670 Vs 13:06:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016773543 +- 0.000000867 Vs 13:06:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016773543 +- 0.000000867 Vs BL = -0.18637270 +- 0.00000963 Tm 13:06:56 Position moved: 0.000000 m 13:06:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18637 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18637 0.00001 -0.18637 0.00000 13:06:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18637 0.00001 SL = -0.1863727 +- 0.0000096 Tm^2/m^n 13:06:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863727 +- 0.0000096 Tm^2/m^n 13:06:59 Position moved: 0.000000 m 13:06:59 Magnet system MAIN current ramping to 87.5000 A... 13:07:13 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:07:15 Main (V) Voltage Measurement, V = 3.119821 V 13:07:20 Temperature Measurement, Probe Number = 0, T = 26.623000 C 13:07:22 Temperature Measurement, Probe Number = 1, T = 28.420000 C 13:07:24 Temperature Measurement, Probe Number = 2, T = 28.448000 C 13:07:26 Temperature Measurement, Probe Number = 3, T = 24.254000 C 13:07:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347051 V 13:07:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347051 (V, A, ohm, ...), Measured Value = 28.709047 (C, atm, Hz, ...) 13:07:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368080 V 13:07:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368080 (V, A, ohm, ...), Measured Value = 29.001112 (C, atm, Hz, ...) 13:07:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.365909 V 13:07:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.365909 (V, A, ohm, ...), Measured Value = 102.443160 (C, atm, Hz, ...) 13:07:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085403 V 13:07:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085403 (V, A, ohm, ...), Measured Value = 6.405225 (C, atm, Hz, ...) 13:07:43 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000944 V 13:07:43 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000944 (V, A, ohm, ...), Measured Value = 0.944476 (C, atm, Hz, ...) 13:07:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.62 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.45 P5 = Ambient, Value = 24.25 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 29.00 P8 = Supply Pres(psi), Value = 102.44 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.94 13:07:43 Magnetic Field Measurement Measuring the magnet strength... 13:07:43 Integrated Voltage Measurement... 13:07:45 Magnet Current for MAIN, Imag = 87.4696 A Vtrans = 0.874691 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775130 Vs 13:08:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770856 Vs 13:08:07 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:08:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777801 Vs 13:08:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771211 Vs 13:08:27 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:08:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780217 Vs 13:08:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768439 Vs 13:08:48 Magnet Current for MAIN, Imag = 87.4690 A Vtrans = 0.874684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:08:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781882 Vs 13:09:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768775 Vs 13:09:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774289 +- 0.000000838 Vs 13:09:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016774289 +- 0.000000838 Vs BL = -0.18638099 +- 0.00000931 Tm 13:09:11 Position moved: 0.000000 m 13:09:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18638 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18638 0.00001 -0.18638 0.00000 13:09:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18638 0.00001 SL = -0.1863810 +- 0.0000093 Tm^2/m^n 13:09:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863810 +- 0.0000093 Tm^2/m^n 13:09:13 Position moved: 0.000000 m 13:09:13 Magnet system MAIN current ramping to 87.5000 A... 13:09:27 Magnet Current for MAIN, Imag = 87.4700 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:09:29 Main (V) Voltage Measurement, V = 3.119955 V 13:09:34 Temperature Measurement, Probe Number = 0, T = 26.644000 C 13:09:36 Temperature Measurement, Probe Number = 1, T = 28.505000 C 13:09:38 Temperature Measurement, Probe Number = 2, T = 28.492000 C 13:09:40 Temperature Measurement, Probe Number = 3, T = 24.273000 C 13:09:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347360 V 13:09:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347360 (V, A, ohm, ...), Measured Value = 28.713335 (C, atm, Hz, ...) 13:09:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.373406 V 13:09:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373406 (V, A, ohm, ...), Measured Value = 29.075079 (C, atm, Hz, ...) 13:09:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.378026 V 13:09:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.378026 (V, A, ohm, ...), Measured Value = 103.351957 (C, atm, Hz, ...) 13:09:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085690 V 13:09:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085690 (V, A, ohm, ...), Measured Value = 6.426728 (C, atm, Hz, ...) 13:09:57 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000945 V 13:09:57 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000945 (V, A, ohm, ...), Measured Value = 0.945293 (C, atm, Hz, ...) 13:09:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.64 P3 = Right Coil Outgoing Side, Value = 28.50 P4 = Left Coil Middle, Value = 28.49 P5 = Ambient, Value = 24.27 P6 = Supply Temp(C), Value = 28.71 P7 = Return Temp(C), Value = 29.08 P8 = Supply Pres(psi), Value = 103.35 P9 = Return Pres(psi), Value = 6.43 P10 = Flow Rate(gpm), Value = 0.95 13:09:57 Magnetic Field Measurement Measuring the magnet strength... 13:09:57 Integrated Voltage Measurement... 13:09:59 Magnet Current for MAIN, Imag = 87.4691 A Vtrans = 0.874686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779015 Vs 13:10:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770455 Vs 13:10:21 Magnet Current for MAIN, Imag = 87.4695 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:10:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780340 Vs 13:10:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770776 Vs 13:10:42 Magnet Current for MAIN, Imag = 87.4700 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:10:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781495 Vs 13:11:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016768381 Vs 13:11:03 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779265 Vs 13:11:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016769762 Vs 13:11:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016774936 +- 0.000000389 Vs 13:11:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016774936 +- 0.000000389 Vs BL = -0.18638818 +- 0.00000432 Tm 13:11:25 Position moved: 0.000000 m 13:11:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18639 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18639 0.00000 -0.18639 0.00000 13:11:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18639 0.00000 SL = -0.1863882 +- 0.0000043 Tm^2/m^n 13:11:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863882 +- 0.0000043 Tm^2/m^n 13:11:28 Position moved: 0.000000 m 13:11:28 Magnet system MAIN current ramping to 75.0000 A... 13:11:49 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:11:51 Main (V) Voltage Measurement, V = 2.675757 V 13:11:56 Temperature Measurement, Probe Number = 0, T = 26.653000 C 13:11:58 Temperature Measurement, Probe Number = 1, T = 28.496000 C 13:12:00 Temperature Measurement, Probe Number = 2, T = 28.499000 C 13:12:02 Temperature Measurement, Probe Number = 3, T = 24.306000 C 13:12:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347767 V 13:12:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347767 (V, A, ohm, ...), Measured Value = 28.718986 (C, atm, Hz, ...) 13:12:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.378449 V 13:12:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378449 (V, A, ohm, ...), Measured Value = 29.145118 (C, atm, Hz, ...) 13:12:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.392953 V 13:12:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.392953 (V, A, ohm, ...), Measured Value = 104.471468 (C, atm, Hz, ...) 13:12:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085444 V 13:12:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085444 (V, A, ohm, ...), Measured Value = 6.408323 (C, atm, Hz, ...) 13:12:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000948 V 13:12:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000948 (V, A, ohm, ...), Measured Value = 0.947672 (C, atm, Hz, ...) 13:12:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.65 P3 = Right Coil Outgoing Side, Value = 28.50 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.31 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 29.15 P8 = Supply Pres(psi), Value = 104.47 P9 = Return Pres(psi), Value = 6.41 P10 = Flow Rate(gpm), Value = 0.95 13:12:19 Magnet system MAIN current ramping to 125.0000 A... 13:13:00 Magnet Current for MAIN, Imag = 124.9929 A Vtrans = 1.249924 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:13:02 Main (V) Voltage Measurement, V = 4.461887 V 13:13:07 Temperature Measurement, Probe Number = 0, T = 26.658000 C 13:13:09 Temperature Measurement, Probe Number = 1, T = 28.520000 C 13:13:12 Temperature Measurement, Probe Number = 2, T = 28.525000 C 13:13:14 Temperature Measurement, Probe Number = 3, T = 24.291000 C 13:13:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347717 V 13:13:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347717 (V, A, ohm, ...), Measured Value = 28.718286 (C, atm, Hz, ...) 13:13:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.379610 V 13:13:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.379610 (V, A, ohm, ...), Measured Value = 29.161246 (C, atm, Hz, ...) 13:13:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.353560 V 13:13:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.353560 (V, A, ohm, ...), Measured Value = 101.517015 (C, atm, Hz, ...) 13:13:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.085332 V 13:13:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.085332 (V, A, ohm, ...), Measured Value = 6.399892 (C, atm, Hz, ...) 13:13:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000933 V 13:13:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000933 (V, A, ohm, ...), Measured Value = 0.932758 (C, atm, Hz, ...) 13:13:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.66 P3 = Right Coil Outgoing Side, Value = 28.52 P4 = Left Coil Middle, Value = 28.52 P5 = Ambient, Value = 24.29 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 29.16 P8 = Supply Pres(psi), Value = 101.52 P9 = Return Pres(psi), Value = 6.40 P10 = Flow Rate(gpm), Value = 0.93 13:13:30 Magnet system MAIN current ramping to 0.0000 A... 13:14:54 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:14:56 Main (V) Voltage Measurement, V = -0.000001 V 13:15:01 Temperature Measurement, Probe Number = 0, T = 26.664000 C 13:15:03 Temperature Measurement, Probe Number = 1, T = 28.653000 C 13:15:05 Temperature Measurement, Probe Number = 2, T = 28.545000 C 13:15:08 Temperature Measurement, Probe Number = 3, T = 24.301000 C 13:15:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348290 V 13:15:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348290 (V, A, ohm, ...), Measured Value = 28.726253 (C, atm, Hz, ...) 13:15:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.385431 V 13:15:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.385431 (V, A, ohm, ...), Measured Value = 29.242103 (C, atm, Hz, ...) 13:15:14 Sensor Voltage Measurement, Sensor Number = 2, V = 2.299867 V 13:15:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.299867 (V, A, ohm, ...), Measured Value = 97.490040 (C, atm, Hz, ...) 13:15:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084067 V 13:15:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084067 (V, A, ohm, ...), Measured Value = 6.305055 (C, atm, Hz, ...) 13:15:24 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 13:15:24 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910308 (C, atm, Hz, ...) 13:15:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.66 P3 = Right Coil Outgoing Side, Value = 28.65 P4 = Left Coil Middle, Value = 28.55 P5 = Ambient, Value = 24.30 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.24 P8 = Supply Pres(psi), Value = 97.49 P9 = Return Pres(psi), Value = 6.31 P10 = Flow Rate(gpm), Value = 0.91 13:15:24 Magnet system MAIN current ramping to 125.0000 A... 13:16:48 Magnet Current for MAIN, Imag = 124.9903 A Vtrans = 1.249898 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:16:50 Main (V) Voltage Measurement, V = 4.462577 V 13:16:55 Temperature Measurement, Probe Number = 0, T = 26.675000 C 13:16:57 Temperature Measurement, Probe Number = 1, T = 28.434000 C 13:17:00 Temperature Measurement, Probe Number = 2, T = 28.458000 C 13:17:02 Temperature Measurement, Probe Number = 3, T = 24.330000 C 13:17:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348315 V 13:17:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348315 (V, A, ohm, ...), Measured Value = 28.726593 (C, atm, Hz, ...) 13:17:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.381696 V 13:17:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.381696 (V, A, ohm, ...), Measured Value = 29.190219 (C, atm, Hz, ...) 13:17:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.298223 V 13:17:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.298223 (V, A, ohm, ...), Measured Value = 97.366717 (C, atm, Hz, ...) 13:17:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083755 V 13:17:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083755 (V, A, ohm, ...), Measured Value = 6.281610 (C, atm, Hz, ...) 13:17:18 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 13:17:18 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.908268 (C, atm, Hz, ...) 13:17:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.68 P3 = Right Coil Outgoing Side, Value = 28.43 P4 = Left Coil Middle, Value = 28.46 P5 = Ambient, Value = 24.33 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.19 P8 = Supply Pres(psi), Value = 97.37 P9 = Return Pres(psi), Value = 6.28 P10 = Flow Rate(gpm), Value = 0.91 13:17:18 Magnet system MAIN current ramping to 0.0000 A... 13:18:43 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:18:45 Main (V) Voltage Measurement, V = -0.000004 V 13:18:50 Temperature Measurement, Probe Number = 0, T = 26.689000 C 13:18:52 Temperature Measurement, Probe Number = 1, T = 28.573000 C 13:18:54 Temperature Measurement, Probe Number = 2, T = 28.520000 C 13:18:56 Temperature Measurement, Probe Number = 3, T = 24.357000 C 13:18:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348304 V 13:18:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348304 (V, A, ohm, ...), Measured Value = 28.726450 (C, atm, Hz, ...) 13:19:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.381652 V 13:19:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.381652 (V, A, ohm, ...), Measured Value = 29.189610 (C, atm, Hz, ...) 13:19:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.299746 V 13:19:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.299746 (V, A, ohm, ...), Measured Value = 97.480935 (C, atm, Hz, ...) 13:19:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083441 V 13:19:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083441 (V, A, ohm, ...), Measured Value = 6.258068 (C, atm, Hz, ...) 13:19:13 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000907 V 13:19:13 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000907 (V, A, ohm, ...), Measured Value = 0.906868 (C, atm, Hz, ...) 13:19:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.69 P3 = Right Coil Outgoing Side, Value = 28.57 P4 = Left Coil Middle, Value = 28.52 P5 = Ambient, Value = 24.36 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.19 P8 = Supply Pres(psi), Value = 97.48 P9 = Return Pres(psi), Value = 6.26 P10 = Flow Rate(gpm), Value = 0.91 13:19:13 Magnet system MAIN current ramping to 125.0000 A... 13:20:37 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:20:39 Main (V) Voltage Measurement, V = 4.463295 V 13:20:44 Temperature Measurement, Probe Number = 0, T = 26.694000 C 13:20:46 Temperature Measurement, Probe Number = 1, T = 28.351000 C 13:20:48 Temperature Measurement, Probe Number = 2, T = 28.467000 C 13:20:50 Temperature Measurement, Probe Number = 3, T = 24.354000 C 13:20:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348374 V 13:20:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348374 (V, A, ohm, ...), Measured Value = 28.727418 (C, atm, Hz, ...) 13:20:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.380159 V 13:20:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.380159 (V, A, ohm, ...), Measured Value = 29.168871 (C, atm, Hz, ...) 13:20:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.305765 V 13:20:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.305765 (V, A, ohm, ...), Measured Value = 97.932382 (C, atm, Hz, ...) 13:20:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083415 V 13:20:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083415 (V, A, ohm, ...), Measured Value = 6.256133 (C, atm, Hz, ...) 13:21:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000932 V 13:21:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000932 (V, A, ohm, ...), Measured Value = 0.931997 (C, atm, Hz, ...) 13:21:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.69 P3 = Right Coil Outgoing Side, Value = 28.35 P4 = Left Coil Middle, Value = 28.47 P5 = Ambient, Value = 24.35 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.17 P8 = Supply Pres(psi), Value = 97.93 P9 = Return Pres(psi), Value = 6.26 P10 = Flow Rate(gpm), Value = 0.93 13:21:07 Magnet system MAIN current ramping to 0.0000 A... 13:22:31 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:22:33 Main (V) Voltage Measurement, V = -0.000001 V 13:22:38 Temperature Measurement, Probe Number = 0, T = 26.690000 C 13:22:40 Temperature Measurement, Probe Number = 1, T = 28.616000 C 13:22:42 Temperature Measurement, Probe Number = 2, T = 28.520000 C 13:22:44 Temperature Measurement, Probe Number = 3, T = 24.350000 C 13:22:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348760 V 13:22:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348760 (V, A, ohm, ...), Measured Value = 28.732782 (C, atm, Hz, ...) 13:22:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.380930 V 13:22:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.380930 (V, A, ohm, ...), Measured Value = 29.179581 (C, atm, Hz, ...) 13:22:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.305565 V 13:22:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.305565 (V, A, ohm, ...), Measured Value = 97.917367 (C, atm, Hz, ...) 13:22:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083207 V 13:22:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083207 (V, A, ohm, ...), Measured Value = 6.240533 (C, atm, Hz, ...) 13:23:00 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 13:23:00 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910257 (C, atm, Hz, ...) 13:23:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.69 P3 = Right Coil Outgoing Side, Value = 28.62 P4 = Left Coil Middle, Value = 28.52 P5 = Ambient, Value = 24.35 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.18 P8 = Supply Pres(psi), Value = 97.92 P9 = Return Pres(psi), Value = 6.24 P10 = Flow Rate(gpm), Value = 0.91 13:23:01 Magnet system MAIN current ramping to 125.0000 A... 13:24:24 Magnet Current for MAIN, Imag = 124.9934 A Vtrans = 1.249929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:24:26 Main (V) Voltage Measurement, V = 4.463435 V 13:24:31 Temperature Measurement, Probe Number = 0, T = 26.699000 C 13:24:33 Temperature Measurement, Probe Number = 1, T = 28.421000 C 13:24:35 Temperature Measurement, Probe Number = 2, T = 28.443000 C 13:24:37 Temperature Measurement, Probe Number = 3, T = 24.395000 C 13:24:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348990 V 13:24:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348990 (V, A, ohm, ...), Measured Value = 28.735975 (C, atm, Hz, ...) 13:24:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.380166 V 13:24:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.380166 (V, A, ohm, ...), Measured Value = 29.168978 (C, atm, Hz, ...) 13:24:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.297097 V 13:24:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.297097 (V, A, ohm, ...), Measured Value = 97.282245 (C, atm, Hz, ...) 13:24:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083272 V 13:24:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083272 (V, A, ohm, ...), Measured Value = 6.245378 (C, atm, Hz, ...) 13:24:54 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000918 V 13:24:54 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000918 (V, A, ohm, ...), Measured Value = 0.918300 (C, atm, Hz, ...) 13:24:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.70 P3 = Right Coil Outgoing Side, Value = 28.42 P4 = Left Coil Middle, Value = 28.44 P5 = Ambient, Value = 24.39 P6 = Supply Temp(C), Value = 28.74 P7 = Return Temp(C), Value = 29.17 P8 = Supply Pres(psi), Value = 97.28 P9 = Return Pres(psi), Value = 6.25 P10 = Flow Rate(gpm), Value = 0.92 13:24:54 Magnet system MAIN current ramping to 0.0000 A... 13:26:17 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:26:19 Main (V) Voltage Measurement, V = 0.000001 V 13:26:24 Temperature Measurement, Probe Number = 0, T = 26.712000 C 13:26:26 Temperature Measurement, Probe Number = 1, T = 28.628000 C 13:26:28 Temperature Measurement, Probe Number = 2, T = 28.501000 C 13:26:30 Temperature Measurement, Probe Number = 3, T = 24.378000 C 13:26:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348477 V 13:26:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348477 (V, A, ohm, ...), Measured Value = 28.728853 (C, atm, Hz, ...) 13:26:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.381186 V 13:26:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.381186 (V, A, ohm, ...), Measured Value = 29.183133 (C, atm, Hz, ...) 13:26:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.307159 V 13:26:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.307159 (V, A, ohm, ...), Measured Value = 98.036918 (C, atm, Hz, ...) 13:26:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083278 V 13:26:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083278 (V, A, ohm, ...), Measured Value = 6.245858 (C, atm, Hz, ...) 13:26:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000893 V 13:26:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000893 (V, A, ohm, ...), Measured Value = 0.892707 (C, atm, Hz, ...) 13:26:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.71 P3 = Right Coil Outgoing Side, Value = 28.63 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.38 P6 = Supply Temp(C), Value = 28.73 P7 = Return Temp(C), Value = 29.18 P8 = Supply Pres(psi), Value = 98.04 P9 = Return Pres(psi), Value = 6.25 P10 = Flow Rate(gpm), Value = 0.89 13:26:47 Magnet system MAIN current ramping to 75.0000 A... 13:27:42 Magnet Current for MAIN, Imag = 75.0229 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:27:44 Main (V) Voltage Measurement, V = 2.672901 V 13:27:49 Temperature Measurement, Probe Number = 0, T = 26.715000 C 13:27:51 Temperature Measurement, Probe Number = 1, T = 28.405000 C 13:27:54 Temperature Measurement, Probe Number = 2, T = 28.289000 C 13:27:56 Temperature Measurement, Probe Number = 3, T = 24.404000 C 13:27:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.348144 V 13:27:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.348144 (V, A, ohm, ...), Measured Value = 28.724225 (C, atm, Hz, ...) 13:28:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.383725 V 13:28:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.383725 (V, A, ohm, ...), Measured Value = 29.218403 (C, atm, Hz, ...) 13:28:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.305370 V 13:28:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.305370 (V, A, ohm, ...), Measured Value = 97.902735 (C, atm, Hz, ...) 13:28:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083409 V 13:28:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083409 (V, A, ohm, ...), Measured Value = 6.255645 (C, atm, Hz, ...) 13:28:12 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000890 V 13:28:12 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000890 (V, A, ohm, ...), Measured Value = 0.890471 (C, atm, Hz, ...) 13:28:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.71 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.29 P5 = Ambient, Value = 24.40 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 29.22 P8 = Supply Pres(psi), Value = 97.90 P9 = Return Pres(psi), Value = 6.26 P10 = Flow Rate(gpm), Value = 0.89 13:28:12 Magnetic Field Measurement Measuring the magnet strength... 13:28:12 Integrated Voltage Measurement... 13:28:14 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:28:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403395 Vs 13:28:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397579 Vs 13:28:36 Magnet Current for MAIN, Imag = 75.0231 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:28:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404237 Vs 13:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398849 Vs 13:28:57 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:29:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405228 Vs 13:29:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396989 Vs 13:29:18 Magnet Current for MAIN, Imag = 75.0229 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404083 Vs 13:29:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395770 Vs 13:29:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400766 +- 0.000000613 Vs 13:29:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014400766 +- 0.000000613 Vs BL = -0.16000852 +- 0.00000681 Tm 13:29:40 Position moved: 0.000000 m 13:29:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00001 -0.16001 0.00000 13:29:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00001 SL = -0.1600085 +- 0.0000068 Tm^2/m^n 13:29:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600085 +- 0.0000068 Tm^2/m^n 13:29:43 Position moved: 0.000000 m 13:29:43 Magnet system MAIN current ramping to 75.0000 A... 13:29:56 Magnet Current for MAIN, Imag = 75.0225 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:29:58 Main (V) Voltage Measurement, V = 2.674702 V 13:30:04 Temperature Measurement, Probe Number = 0, T = 26.726000 C 13:30:06 Temperature Measurement, Probe Number = 1, T = 28.345000 C 13:30:08 Temperature Measurement, Probe Number = 2, T = 28.373000 C 13:30:10 Temperature Measurement, Probe Number = 3, T = 24.422000 C 13:30:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347714 V 13:30:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347714 (V, A, ohm, ...), Measured Value = 28.718251 (C, atm, Hz, ...) 13:30:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369505 V 13:30:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369505 (V, A, ohm, ...), Measured Value = 29.020900 (C, atm, Hz, ...) 13:30:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.296416 V 13:30:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.296416 (V, A, ohm, ...), Measured Value = 97.231192 (C, atm, Hz, ...) 13:30:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083380 V 13:30:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083380 (V, A, ohm, ...), Measured Value = 6.253515 (C, atm, Hz, ...) 13:30:26 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 13:30:26 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905383 (C, atm, Hz, ...) 13:30:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.73 P3 = Right Coil Outgoing Side, Value = 28.34 P4 = Left Coil Middle, Value = 28.37 P5 = Ambient, Value = 24.42 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 29.02 P8 = Supply Pres(psi), Value = 97.23 P9 = Return Pres(psi), Value = 6.25 P10 = Flow Rate(gpm), Value = 0.91 13:30:26 Magnetic Field Measurement Measuring the magnet strength... 13:30:26 Integrated Voltage Measurement... 13:30:29 Magnet Current for MAIN, Imag = 75.0229 A Vtrans = 0.750224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:30:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404390 Vs 13:30:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396560 Vs 13:30:50 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:31:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406449 Vs 13:31:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396843 Vs 13:31:11 Magnet Current for MAIN, Imag = 75.0225 A Vtrans = 0.750220 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:31:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402504 Vs 13:31:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398697 Vs 13:31:32 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405119 Vs 13:31:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397879 Vs 13:31:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401055 +- 0.000000522 Vs 13:31:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401055 +- 0.000000522 Vs BL = -0.16001172 +- 0.00000580 Tm 13:31:54 Position moved: 0.000000 m 13:31:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00001 -0.16001 0.00000 13:31:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00001 SL = -0.1600117 +- 0.0000058 Tm^2/m^n 13:31:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600117 +- 0.0000058 Tm^2/m^n 13:31:57 Position moved: 0.000000 m 13:31:57 Magnet system MAIN current ramping to 75.0000 A... 13:32:10 Magnet Current for MAIN, Imag = 75.0239 A Vtrans = 0.750234 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:32:12 Main (V) Voltage Measurement, V = 2.674749 V 13:32:18 Temperature Measurement, Probe Number = 0, T = 26.731000 C 13:32:20 Temperature Measurement, Probe Number = 1, T = 28.387000 C 13:32:22 Temperature Measurement, Probe Number = 2, T = 28.418000 C 13:32:24 Temperature Measurement, Probe Number = 3, T = 24.442000 C 13:32:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347631 V 13:32:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347631 (V, A, ohm, ...), Measured Value = 28.717103 (C, atm, Hz, ...) 13:32:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.367002 V 13:32:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.367002 (V, A, ohm, ...), Measured Value = 28.986132 (C, atm, Hz, ...) 13:32:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.297936 V 13:32:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.297936 (V, A, ohm, ...), Measured Value = 97.345215 (C, atm, Hz, ...) 13:32:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083322 V 13:32:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083322 (V, A, ohm, ...), Measured Value = 6.249157 (C, atm, Hz, ...) 13:32:40 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 13:32:40 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907593 (C, atm, Hz, ...) 13:32:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.73 P3 = Right Coil Outgoing Side, Value = 28.39 P4 = Left Coil Middle, Value = 28.42 P5 = Ambient, Value = 24.44 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 28.99 P8 = Supply Pres(psi), Value = 97.35 P9 = Return Pres(psi), Value = 6.25 P10 = Flow Rate(gpm), Value = 0.91 13:32:40 Magnetic Field Measurement Measuring the magnet strength... 13:32:40 Integrated Voltage Measurement... 13:32:42 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403286 Vs 13:33:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396352 Vs 13:33:04 Magnet Current for MAIN, Imag = 75.0235 A Vtrans = 0.750230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:33:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405235 Vs 13:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397690 Vs 13:33:25 Magnet Current for MAIN, Imag = 75.0227 A Vtrans = 0.750222 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404815 Vs 13:33:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397393 Vs 13:33:46 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:33:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401665 Vs 13:34:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398491 Vs 13:34:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014400616 +- 0.000000686 Vs 13:34:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014400616 +- 0.000000686 Vs BL = -0.16000684 +- 0.00000762 Tm 13:34:08 Position moved: 0.000000 m 13:34:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16001 0.00001 -0.16001 0.00000 13:34:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16001 0.00001 SL = -0.1600068 +- 0.0000076 Tm^2/m^n 13:34:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600068 +- 0.0000076 Tm^2/m^n 13:34:11 Position moved: 0.000000 m 13:34:11 Magnet system MAIN current ramping to 125.0000 A... 13:34:50 Magnet system MAIN current ramping to 0.0000 A... 13:36:12 Magnet system MAIN current ramping to 125.0000 A... 13:37:34 Magnet system MAIN current ramping to 0.0000 A... 13:38:55 Magnet system MAIN current ramping to 125.0000 A... 13:40:18 Magnet system MAIN current ramping to 0.0000 A... 13:41:43 Position moved: 0.000000 m 13:41:46 Magnet system MAIN current ramping to 87.5000 A... 13:42:49 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:42:51 Main (V) Voltage Measurement, V = 3.117500 V 13:42:56 Temperature Measurement, Probe Number = 0, T = 26.774000 C 13:42:58 Temperature Measurement, Probe Number = 1, T = 28.406000 C 13:43:00 Temperature Measurement, Probe Number = 2, T = 28.313000 C 13:43:02 Temperature Measurement, Probe Number = 3, T = 24.508000 C 13:43:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.346302 V 13:43:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.346302 (V, A, ohm, ...), Measured Value = 28.698642 (C, atm, Hz, ...) 13:43:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.375815 V 13:43:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375815 (V, A, ohm, ...), Measured Value = 29.108537 (C, atm, Hz, ...) 13:43:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.312181 V 13:43:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.312181 (V, A, ohm, ...), Measured Value = 98.413575 (C, atm, Hz, ...) 13:43:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083898 V 13:43:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083898 (V, A, ohm, ...), Measured Value = 6.292365 (C, atm, Hz, ...) 13:43:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 13:43:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910273 (C, atm, Hz, ...) 13:43:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.77 P3 = Right Coil Outgoing Side, Value = 28.41 P4 = Left Coil Middle, Value = 28.31 P5 = Ambient, Value = 24.51 P6 = Supply Temp(C), Value = 28.70 P7 = Return Temp(C), Value = 29.11 P8 = Supply Pres(psi), Value = 98.41 P9 = Return Pres(psi), Value = 6.29 P10 = Flow Rate(gpm), Value = 0.91 13:43:19 Magnetic Field Measurement Measuring the magnet strength... 13:43:19 Integrated Voltage Measurement... 13:43:21 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:43:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781083 Vs 13:43:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771436 Vs 13:43:43 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:43:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781974 Vs 13:44:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016770606 Vs 13:44:03 Magnet Current for MAIN, Imag = 87.4695 A Vtrans = 0.874690 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:44:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781309 Vs 13:44:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772385 Vs 13:44:24 Magnet Current for MAIN, Imag = 87.4700 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:44:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782840 Vs 13:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016769806 Vs 13:44:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776430 +- 0.000000242 Vs 13:44:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776430 +- 0.000000242 Vs BL = -0.18640478 +- 0.00000269 Tm 13:44:47 Position moved: 0.000000 m 13:44:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18640 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18640 0.00000 -0.18640 0.00000 13:44:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18640 0.00000 SL = -0.1864048 +- 0.0000027 Tm^2/m^n 13:44:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864048 +- 0.0000027 Tm^2/m^n 13:44:50 Position moved: 0.000000 m 13:44:50 Magnet system MAIN current ramping to 87.5000 A... 13:45:03 Magnet Current for MAIN, Imag = 87.4704 A Vtrans = 0.874699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:45:05 Main (V) Voltage Measurement, V = 3.120427 V 13:45:10 Temperature Measurement, Probe Number = 0, T = 26.779000 C 13:45:12 Temperature Measurement, Probe Number = 1, T = 28.466000 C 13:45:14 Temperature Measurement, Probe Number = 2, T = 28.417000 C 13:45:16 Temperature Measurement, Probe Number = 3, T = 24.482000 C 13:45:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.347807 V 13:45:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.347807 (V, A, ohm, ...), Measured Value = 28.719543 (C, atm, Hz, ...) 13:45:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.369878 V 13:45:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.369878 (V, A, ohm, ...), Measured Value = 29.026085 (C, atm, Hz, ...) 13:45:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.302134 V 13:45:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.302134 (V, A, ohm, ...), Measured Value = 97.660065 (C, atm, Hz, ...) 13:45:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083853 V 13:45:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083853 (V, A, ohm, ...), Measured Value = 6.288967 (C, atm, Hz, ...) 13:45:33 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 13:45:33 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.904723 (C, atm, Hz, ...) 13:45:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.78 P3 = Right Coil Outgoing Side, Value = 28.47 P4 = Left Coil Middle, Value = 28.42 P5 = Ambient, Value = 24.48 P6 = Supply Temp(C), Value = 28.72 P7 = Return Temp(C), Value = 29.03 P8 = Supply Pres(psi), Value = 97.66 P9 = Return Pres(psi), Value = 6.29 P10 = Flow Rate(gpm), Value = 0.90 13:45:33 Magnetic Field Measurement Measuring the magnet strength... 13:45:33 Integrated Voltage Measurement... 13:45:35 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:45:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778592 Vs 13:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772022 Vs 13:45:57 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782026 Vs 13:46:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771117 Vs 13:46:17 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:46:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780142 Vs 13:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771701 Vs 13:46:38 Magnet Current for MAIN, Imag = 87.4697 A Vtrans = 0.874692 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:46:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777123 Vs 13:46:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771205 Vs 13:46:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016775491 +- 0.000000887 Vs 13:46:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016775491 +- 0.000000887 Vs BL = -0.18639434 +- 0.00000986 Tm 13:47:01 Position moved: 0.000000 m 13:47:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18639 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18639 0.00001 -0.18639 0.00000 13:47:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18639 0.00001 SL = -0.1863943 +- 0.0000099 Tm^2/m^n 13:47:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1863943 +- 0.0000099 Tm^2/m^n 13:47:04 Position moved: 0.000000 m 13:47:04 Magnet system MAIN current ramping to 87.5000 A... 13:47:17 Magnet Current for MAIN, Imag = 87.4700 A Vtrans = 0.874695 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:47:19 Main (V) Voltage Measurement, V = 3.120504 V 13:47:25 Temperature Measurement, Probe Number = 0, T = 26.785000 C 13:47:27 Temperature Measurement, Probe Number = 1, T = 28.579000 C 13:47:29 Temperature Measurement, Probe Number = 2, T = 28.505000 C 13:47:31 Temperature Measurement, Probe Number = 3, T = 24.495000 C 13:47:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.349485 V 13:47:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349485 (V, A, ohm, ...), Measured Value = 28.742847 (C, atm, Hz, ...) 13:47:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374982 V 13:47:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374982 (V, A, ohm, ...), Measured Value = 29.096967 (C, atm, Hz, ...) 13:47:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.302740 V 13:47:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.302740 (V, A, ohm, ...), Measured Value = 97.705500 (C, atm, Hz, ...) 13:47:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083956 V 13:47:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083956 (V, A, ohm, ...), Measured Value = 6.296723 (C, atm, Hz, ...) 13:47:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000920 V 13:47:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000920 (V, A, ohm, ...), Measured Value = 0.920199 (C, atm, Hz, ...) 13:47:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.79 P3 = Right Coil Outgoing Side, Value = 28.58 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.50 P6 = Supply Temp(C), Value = 28.74 P7 = Return Temp(C), Value = 29.10 P8 = Supply Pres(psi), Value = 97.71 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.92 13:47:47 Magnetic Field Measurement Measuring the magnet strength... 13:47:47 Integrated Voltage Measurement... 13:47:49 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:48:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777973 Vs 13:48:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773697 Vs 13:48:11 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:48:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778887 Vs 13:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773737 Vs 13:48:32 Magnet Current for MAIN, Imag = 87.4705 A Vtrans = 0.874700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779413 Vs 13:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772396 Vs 13:48:53 Magnet Current for MAIN, Imag = 87.4699 A Vtrans = 0.874694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779803 Vs 13:49:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774703 Vs 13:49:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776326 +- 0.000000565 Vs 13:49:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776326 +- 0.000000565 Vs BL = -0.18640362 +- 0.00000628 Tm 13:49:15 Position moved: 0.000000 m 13:49:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18640 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18640 0.00001 -0.18640 0.00000 13:49:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18640 0.00001 SL = -0.1864036 +- 0.0000063 Tm^2/m^n 13:49:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864036 +- 0.0000063 Tm^2/m^n 13:49:18 Position moved: 0.000000 m 13:49:18 Magnet system MAIN current ramping to 75.0000 A... 13:49:39 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:49:41 Main (V) Voltage Measurement, V = 2.676218 V 13:49:46 Temperature Measurement, Probe Number = 0, T = 26.787000 C 13:49:48 Temperature Measurement, Probe Number = 1, T = 28.651000 C 13:49:50 Temperature Measurement, Probe Number = 2, T = 28.530000 C 13:49:52 Temperature Measurement, Probe Number = 3, T = 24.512000 C 13:49:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.349313 V 13:49:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349313 (V, A, ohm, ...), Measured Value = 28.740461 (C, atm, Hz, ...) 13:49:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.380359 V 13:49:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.380359 (V, A, ohm, ...), Measured Value = 29.171651 (C, atm, Hz, ...) 13:49:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.313307 V 13:49:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.313307 (V, A, ohm, ...), Measured Value = 98.498055 (C, atm, Hz, ...) 13:50:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084060 V 13:50:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084060 (V, A, ohm, ...), Measured Value = 6.304470 (C, atm, Hz, ...) 13:50:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 13:50:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907950 (C, atm, Hz, ...) 13:50:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.79 P3 = Right Coil Outgoing Side, Value = 28.65 P4 = Left Coil Middle, Value = 28.53 P5 = Ambient, Value = 24.51 P6 = Supply Temp(C), Value = 28.74 P7 = Return Temp(C), Value = 29.17 P8 = Supply Pres(psi), Value = 98.50 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.91 13:50:09 Magnet system MAIN current ramping to 125.0000 A... 13:50:50 Magnet Current for MAIN, Imag = 124.9947 A Vtrans = 1.249942 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:50:53 Main (V) Voltage Measurement, V = 4.462944 V 13:50:58 Temperature Measurement, Probe Number = 0, T = 26.793000 C 13:51:00 Temperature Measurement, Probe Number = 1, T = 28.659000 C 13:51:02 Temperature Measurement, Probe Number = 2, T = 28.569000 C 13:51:04 Temperature Measurement, Probe Number = 3, T = 24.483000 C 13:51:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.349174 V 13:51:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349174 (V, A, ohm, ...), Measured Value = 28.738524 (C, atm, Hz, ...) 13:51:08 Sensor Voltage Measurement, Sensor Number = 1, V = 2.382029 V 13:51:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.382029 (V, A, ohm, ...), Measured Value = 29.194847 (C, atm, Hz, ...) 13:51:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.310166 V 13:51:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.310166 (V, A, ohm, ...), Measured Value = 98.262450 (C, atm, Hz, ...) 13:51:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084204 V 13:51:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084204 (V, A, ohm, ...), Measured Value = 6.315322 (C, atm, Hz, ...) 13:51:20 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 13:51:20 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.910422 (C, atm, Hz, ...) 13:51:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.79 P3 = Right Coil Outgoing Side, Value = 28.66 P4 = Left Coil Middle, Value = 28.57 P5 = Ambient, Value = 24.48 P6 = Supply Temp(C), Value = 28.74 P7 = Return Temp(C), Value = 29.19 P8 = Supply Pres(psi), Value = 98.26 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.91 13:51:20 Magnet system MAIN current ramping to 0.0000 A... 13:52:45 Magnet Current for MAIN, Imag = 0.0005 A Vtrans = 0.000000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:52:47 Main (V) Voltage Measurement, V = 0.000000 V 13:52:52 Temperature Measurement, Probe Number = 0, T = 26.803000 C 13:52:54 Temperature Measurement, Probe Number = 1, T = 28.756000 C 13:52:56 Temperature Measurement, Probe Number = 2, T = 28.565000 C 13:52:58 Temperature Measurement, Probe Number = 3, T = 24.512000 C 13:53:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.349987 V 13:53:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.349987 (V, A, ohm, ...), Measured Value = 28.749825 (C, atm, Hz, ...) 13:53:03 Sensor Voltage Measurement, Sensor Number = 1, V = 2.387975 V 13:53:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.387975 (V, A, ohm, ...), Measured Value = 29.277426 (C, atm, Hz, ...) 13:53:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.313788 V 13:53:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.313788 (V, A, ohm, ...), Measured Value = 98.534092 (C, atm, Hz, ...) 13:53:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083876 V 13:53:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083876 (V, A, ohm, ...), Measured Value = 6.290715 (C, atm, Hz, ...) 13:53:15 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000912 V 13:53:15 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000912 (V, A, ohm, ...), Measured Value = 0.912219 (C, atm, Hz, ...) 13:53:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.80 P3 = Right Coil Outgoing Side, Value = 28.76 P4 = Left Coil Middle, Value = 28.57 P5 = Ambient, Value = 24.51 P6 = Supply Temp(C), Value = 28.75 P7 = Return Temp(C), Value = 29.28 P8 = Supply Pres(psi), Value = 98.53 P9 = Return Pres(psi), Value = 6.29 P10 = Flow Rate(gpm), Value = 0.91 13:53:15 Magnet system MAIN current ramping to 125.0000 A... 13:54:39 Magnet Current for MAIN, Imag = 124.9927 A Vtrans = 1.249921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:54:41 Main (V) Voltage Measurement, V = 4.463397 V 13:54:47 Temperature Measurement, Probe Number = 0, T = 26.809000 C 13:54:49 Temperature Measurement, Probe Number = 1, T = 28.482000 C 13:54:51 Temperature Measurement, Probe Number = 2, T = 28.489000 C 13:54:53 Temperature Measurement, Probe Number = 3, T = 24.500000 C 13:54:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.350334 V 13:54:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350334 (V, A, ohm, ...), Measured Value = 28.754633 (C, atm, Hz, ...) 13:54:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.384246 V 13:54:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.384246 (V, A, ohm, ...), Measured Value = 29.225633 (C, atm, Hz, ...) 13:54:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.313513 V 13:54:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.313513 (V, A, ohm, ...), Measured Value = 98.513452 (C, atm, Hz, ...) 13:55:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084280 V 13:55:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084280 (V, A, ohm, ...), Measured Value = 6.321037 (C, atm, Hz, ...) 13:55:09 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000925 V 13:55:09 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000925 (V, A, ohm, ...), Measured Value = 0.925336 (C, atm, Hz, ...) 13:55:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.81 P3 = Right Coil Outgoing Side, Value = 28.48 P4 = Left Coil Middle, Value = 28.49 P5 = Ambient, Value = 24.50 P6 = Supply Temp(C), Value = 28.75 P7 = Return Temp(C), Value = 29.23 P8 = Supply Pres(psi), Value = 98.51 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.93 13:55:09 Magnet system MAIN current ramping to 0.0000 A... 13:56:33 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:56:35 Main (V) Voltage Measurement, V = 0.000000 V 13:56:40 Temperature Measurement, Probe Number = 0, T = 26.820000 C 13:56:43 Temperature Measurement, Probe Number = 1, T = 28.691000 C 13:56:45 Temperature Measurement, Probe Number = 2, T = 28.567000 C 13:56:47 Temperature Measurement, Probe Number = 3, T = 24.501000 C 13:56:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.350553 V 13:56:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350553 (V, A, ohm, ...), Measured Value = 28.757683 (C, atm, Hz, ...) 13:56:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.384479 V 13:56:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.384479 (V, A, ohm, ...), Measured Value = 29.228881 (C, atm, Hz, ...) 13:56:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.309258 V 13:56:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.309258 (V, A, ohm, ...), Measured Value = 98.194343 (C, atm, Hz, ...) 13:56:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084087 V 13:56:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084087 (V, A, ohm, ...), Measured Value = 6.306503 (C, atm, Hz, ...) 13:57:03 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000904 V 13:57:03 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000904 (V, A, ohm, ...), Measured Value = 0.904451 (C, atm, Hz, ...) 13:57:03 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 26.82 P3 = Right Coil Outgoing Side, Value = 28.69 P4 = Left Coil Middle, Value = 28.57 P5 = Ambient, Value = 24.50 P6 = Supply Temp(C), Value = 28.76 P7 = Return Temp(C), Value = 29.23 P8 = Supply Pres(psi), Value = 98.19 P9 = Return Pres(psi), Value = 6.31 P10 = Flow Rate(gpm), Value = 0.90 13:57:03 Magnet system MAIN current ramping to 125.0000 A... 13:58:28 Magnet Current for MAIN, Imag = 124.9946 A Vtrans = 1.249941 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 13:58:30 Main (V) Voltage Measurement, V = 4.463911 V 13:58:35 Temperature Measurement, Probe Number = 0, T = 26.828000 C 13:58:37 Temperature Measurement, Probe Number = 1, T = 28.482000 C 13:58:39 Temperature Measurement, Probe Number = 2, T = 28.481000 C 13:58:41 Temperature Measurement, Probe Number = 3, T = 24.473000 C 13:58:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.350703 V 13:58:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.350703 (V, A, ohm, ...), Measured Value = 28.759764 (C, atm, Hz, ...) 13:58:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.382773 V 13:58:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.382773 (V, A, ohm, ...), Measured Value = 29.205182 (C, atm, Hz, ...) 13:58:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.320521 V 13:58:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.320521 (V, A, ohm, ...), Measured Value = 99.039105 (C, atm, Hz, ...) 13:58:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084036 V 13:58:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084036 (V, A, ohm, ...), Measured Value = 6.302730 (C, atm, Hz, ...) 13:58:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000912 V 13:58:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000912 (V, A, ohm, ...), Measured Value = 0.912272 (C, atm, Hz, ...) 13:58:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.83 P3 = Right Coil Outgoing Side, Value = 28.48 P4 = Left Coil Middle, Value = 28.48 P5 = Ambient, Value = 24.47 P6 = Supply Temp(C), Value = 28.76 P7 = Return Temp(C), Value = 29.21 P8 = Supply Pres(psi), Value = 99.04 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.91 13:58:58 Magnet system MAIN current ramping to 0.0000 A... 14:00:23 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:00:25 Main (V) Voltage Measurement, V = -0.000004 V 14:00:30 Temperature Measurement, Probe Number = 0, T = 26.844000 C 14:00:32 Temperature Measurement, Probe Number = 1, T = 28.616000 C 14:00:34 Temperature Measurement, Probe Number = 2, T = 28.561000 C 14:00:36 Temperature Measurement, Probe Number = 3, T = 24.508000 C 14:00:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.351956 V 14:00:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.351956 (V, A, ohm, ...), Measured Value = 28.777167 (C, atm, Hz, ...) 14:00:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.383715 V 14:00:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.383715 (V, A, ohm, ...), Measured Value = 29.218260 (C, atm, Hz, ...) 14:00:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.312421 V 14:00:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.312421 (V, A, ohm, ...), Measured Value = 98.431597 (C, atm, Hz, ...) 14:00:45 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084268 V 14:00:45 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084268 (V, A, ohm, ...), Measured Value = 6.320070 (C, atm, Hz, ...) 14:00:53 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000910 V 14:00:53 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000910 (V, A, ohm, ...), Measured Value = 0.909910 (C, atm, Hz, ...) 14:00:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.84 P3 = Right Coil Outgoing Side, Value = 28.62 P4 = Left Coil Middle, Value = 28.56 P5 = Ambient, Value = 24.51 P6 = Supply Temp(C), Value = 28.78 P7 = Return Temp(C), Value = 29.22 P8 = Supply Pres(psi), Value = 98.43 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.91 14:00:53 Magnet system MAIN current ramping to 125.0000 A... 14:02:17 Magnet Current for MAIN, Imag = 124.9933 A Vtrans = 1.249928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:02:20 Main (V) Voltage Measurement, V = 4.463945 V 14:02:25 Temperature Measurement, Probe Number = 0, T = 26.839000 C 14:02:27 Temperature Measurement, Probe Number = 1, T = 28.450000 C 14:02:29 Temperature Measurement, Probe Number = 2, T = 28.503000 C 14:02:31 Temperature Measurement, Probe Number = 3, T = 24.530000 C 14:02:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352306 V 14:02:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352306 (V, A, ohm, ...), Measured Value = 28.782028 (C, atm, Hz, ...) 14:02:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.382543 V 14:02:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.382543 (V, A, ohm, ...), Measured Value = 29.201988 (C, atm, Hz, ...) 14:02:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.309201 V 14:02:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.309201 (V, A, ohm, ...), Measured Value = 98.190083 (C, atm, Hz, ...) 14:02:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083986 V 14:02:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083986 (V, A, ohm, ...), Measured Value = 6.298950 (C, atm, Hz, ...) 14:02:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 14:02:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.903084 (C, atm, Hz, ...) 14:02:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.84 P3 = Right Coil Outgoing Side, Value = 28.45 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.53 P6 = Supply Temp(C), Value = 28.78 P7 = Return Temp(C), Value = 29.20 P8 = Supply Pres(psi), Value = 98.19 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.90 14:02:47 Magnet system MAIN current ramping to 0.0000 A... 14:04:11 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:04:14 Main (V) Voltage Measurement, V = -0.000001 V 14:04:19 Temperature Measurement, Probe Number = 0, T = 26.841000 C 14:04:21 Temperature Measurement, Probe Number = 1, T = 28.711000 C 14:04:23 Temperature Measurement, Probe Number = 2, T = 28.538000 C 14:04:25 Temperature Measurement, Probe Number = 3, T = 24.557000 C 14:04:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.352914 V 14:04:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.352914 (V, A, ohm, ...), Measured Value = 28.790478 (C, atm, Hz, ...) 14:04:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.384138 V 14:04:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.384138 (V, A, ohm, ...), Measured Value = 29.224144 (C, atm, Hz, ...) 14:04:31 Sensor Voltage Measurement, Sensor Number = 2, V = 2.312368 V 14:04:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.312368 (V, A, ohm, ...), Measured Value = 98.427623 (C, atm, Hz, ...) 14:04:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083912 V 14:04:34 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083912 (V, A, ohm, ...), Measured Value = 6.293430 (C, atm, Hz, ...) 14:04:41 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000912 V 14:04:41 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000912 (V, A, ohm, ...), Measured Value = 0.912334 (C, atm, Hz, ...) 14:04:41 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.84 P3 = Right Coil Outgoing Side, Value = 28.71 P4 = Left Coil Middle, Value = 28.54 P5 = Ambient, Value = 24.56 P6 = Supply Temp(C), Value = 28.79 P7 = Return Temp(C), Value = 29.22 P8 = Supply Pres(psi), Value = 98.43 P9 = Return Pres(psi), Value = 6.29 P10 = Flow Rate(gpm), Value = 0.91 14:04:41 Magnet system MAIN current ramping to 75.0000 A... 14:05:37 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:05:39 Main (V) Voltage Measurement, V = 2.673583 V 14:05:45 Temperature Measurement, Probe Number = 0, T = 26.846000 C 14:05:47 Temperature Measurement, Probe Number = 1, T = 28.466000 C 14:05:49 Temperature Measurement, Probe Number = 2, T = 28.367000 C 14:05:51 Temperature Measurement, Probe Number = 3, T = 24.554000 C 14:05:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353603 V 14:05:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353603 (V, A, ohm, ...), Measured Value = 28.800040 (C, atm, Hz, ...) 14:05:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.386731 V 14:05:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.386731 (V, A, ohm, ...), Measured Value = 29.260150 (C, atm, Hz, ...) 14:05:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.314949 V 14:05:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.314949 (V, A, ohm, ...), Measured Value = 98.621183 (C, atm, Hz, ...) 14:06:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084278 V 14:06:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084278 (V, A, ohm, ...), Measured Value = 6.320843 (C, atm, Hz, ...) 14:06:07 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 14:06:07 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.912990 (C, atm, Hz, ...) 14:06:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.85 P3 = Right Coil Outgoing Side, Value = 28.47 P4 = Left Coil Middle, Value = 28.37 P5 = Ambient, Value = 24.55 P6 = Supply Temp(C), Value = 28.80 P7 = Return Temp(C), Value = 29.26 P8 = Supply Pres(psi), Value = 98.62 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.91 14:06:07 Magnetic Field Measurement Measuring the magnet strength... 14:06:07 Integrated Voltage Measurement... 14:06:09 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:06:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404955 Vs 14:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399243 Vs 14:06:31 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:06:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407271 Vs 14:06:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399671 Vs 14:06:52 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:07:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404447 Vs 14:07:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398426 Vs 14:07:13 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:07:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406048 Vs 14:07:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398509 Vs 14:07:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402321 +- 0.000000734 Vs 14:07:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014402321 +- 0.000000734 Vs BL = -0.16002579 +- 0.00000816 Tm 14:07:36 Position moved: 0.000000 m 14:07:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16003 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16003 0.00001 -0.16003 0.00000 14:07:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16003 0.00001 SL = -0.1600258 +- 0.0000082 Tm^2/m^n 14:07:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600258 +- 0.0000082 Tm^2/m^n 14:07:39 Position moved: 0.000000 m 14:07:39 Magnet system MAIN current ramping to 75.0000 A... 14:07:52 Magnet Current for MAIN, Imag = 75.0239 A Vtrans = 0.750234 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:07:54 Main (V) Voltage Measurement, V = 2.675515 V 14:07:59 Temperature Measurement, Probe Number = 0, T = 26.856000 C 14:08:01 Temperature Measurement, Probe Number = 1, T = 28.444000 C 14:08:03 Temperature Measurement, Probe Number = 2, T = 28.470000 C 14:08:05 Temperature Measurement, Probe Number = 3, T = 24.579000 C 14:08:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.354857 V 14:08:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354857 (V, A, ohm, ...), Measured Value = 28.817460 (C, atm, Hz, ...) 14:08:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372832 V 14:08:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372832 (V, A, ohm, ...), Measured Value = 29.067114 (C, atm, Hz, ...) 14:08:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.311172 V 14:08:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.311172 (V, A, ohm, ...), Measured Value = 98.337915 (C, atm, Hz, ...) 14:08:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084185 V 14:08:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084185 (V, A, ohm, ...), Measured Value = 6.313867 (C, atm, Hz, ...) 14:08:22 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 14:08:22 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.913338 (C, atm, Hz, ...) 14:08:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.86 P3 = Right Coil Outgoing Side, Value = 28.44 P4 = Left Coil Middle, Value = 28.47 P5 = Ambient, Value = 24.58 P6 = Supply Temp(C), Value = 28.82 P7 = Return Temp(C), Value = 29.07 P8 = Supply Pres(psi), Value = 98.34 P9 = Return Pres(psi), Value = 6.31 P10 = Flow Rate(gpm), Value = 0.91 14:08:22 Magnetic Field Measurement Measuring the magnet strength... 14:08:22 Integrated Voltage Measurement... 14:08:24 Magnet Current for MAIN, Imag = 75.0235 A Vtrans = 0.750230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:08:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408964 Vs 14:08:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396289 Vs 14:08:46 Magnet Current for MAIN, Imag = 75.0231 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:08:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407287 Vs 14:09:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398140 Vs 14:09:07 Magnet Current for MAIN, Imag = 75.0236 A Vtrans = 0.750231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:09:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406924 Vs 14:09:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398305 Vs 14:09:28 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:09:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405856 Vs 14:09:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398817 Vs 14:09:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014402573 +- 0.000000142 Vs 14:09:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014402573 +- 0.000000142 Vs BL = -0.16002858 +- 0.00000157 Tm 14:09:51 Position moved: 0.000000 m 14:09:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16003 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16003 0.00000 -0.16003 0.00000 14:09:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16003 0.00000 SL = -0.1600286 +- 0.0000016 Tm^2/m^n 14:09:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600286 +- 0.0000016 Tm^2/m^n 14:09:54 Position moved: 0.000000 m 14:09:54 Magnet system MAIN current ramping to 75.0000 A... 14:10:07 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:10:09 Main (V) Voltage Measurement, V = 2.675772 V 14:10:15 Temperature Measurement, Probe Number = 0, T = 26.864000 C 14:10:17 Temperature Measurement, Probe Number = 1, T = 28.487000 C 14:10:19 Temperature Measurement, Probe Number = 2, T = 28.497000 C 14:10:21 Temperature Measurement, Probe Number = 3, T = 24.572000 C 14:10:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355400 V 14:10:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355400 (V, A, ohm, ...), Measured Value = 28.824994 (C, atm, Hz, ...) 14:10:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.371756 V 14:10:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371756 (V, A, ohm, ...), Measured Value = 29.052171 (C, atm, Hz, ...) 14:10:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.311378 V 14:10:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.311378 (V, A, ohm, ...), Measured Value = 98.353320 (C, atm, Hz, ...) 14:10:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.083987 V 14:10:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.083987 (V, A, ohm, ...), Measured Value = 6.299047 (C, atm, Hz, ...) 14:10:37 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 14:10:37 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.912966 (C, atm, Hz, ...) 14:10:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.86 P3 = Right Coil Outgoing Side, Value = 28.49 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.57 P6 = Supply Temp(C), Value = 28.82 P7 = Return Temp(C), Value = 29.05 P8 = Supply Pres(psi), Value = 98.35 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.91 14:10:37 Magnetic Field Measurement Measuring the magnet strength... 14:10:37 Integrated Voltage Measurement... 14:10:39 Magnet Current for MAIN, Imag = 75.0231 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:10:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407779 Vs 14:10:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014395917 Vs 14:11:01 Magnet Current for MAIN, Imag = 75.0231 A Vtrans = 0.750226 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405521 Vs 14:11:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396446 Vs 14:11:22 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:11:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405476 Vs 14:11:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399019 Vs 14:11:43 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014406347 Vs 14:12:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398956 Vs 14:12:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014401933 +- 0.000000617 Vs 14:12:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014401933 +- 0.000000617 Vs BL = -0.16002147 +- 0.00000686 Tm 14:12:06 Position moved: 0.000000 m 14:12:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16002 0.00001 -0.16002 0.00000 14:12:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16002 0.00001 SL = -0.1600215 +- 0.0000069 Tm^2/m^n 14:12:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600215 +- 0.0000069 Tm^2/m^n 14:12:09 Position moved: 0.000000 m 14:12:09 Magnet system MAIN current ramping to 125.0000 A... 14:12:48 Magnet system MAIN current ramping to 0.0000 A... 14:14:11 Magnet system MAIN current ramping to 125.0000 A... 14:15:33 Magnet system MAIN current ramping to 0.0000 A... 14:16:54 Magnet system MAIN current ramping to 125.0000 A... 14:18:16 Magnet system MAIN current ramping to 0.0000 A... 14:19:42 Position moved: 0.000000 m 14:19:45 Magnet system MAIN current ramping to 87.5000 A... 14:20:47 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:20:50 Main (V) Voltage Measurement, V = 3.119236 V 14:20:55 Temperature Measurement, Probe Number = 0, T = 26.901000 C 14:20:57 Temperature Measurement, Probe Number = 1, T = 28.565000 C 14:20:59 Temperature Measurement, Probe Number = 2, T = 28.475000 C 14:21:01 Temperature Measurement, Probe Number = 3, T = 24.652000 C 14:21:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356277 V 14:21:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356277 (V, A, ohm, ...), Measured Value = 28.837176 (C, atm, Hz, ...) 14:21:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.384925 V 14:21:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.384925 (V, A, ohm, ...), Measured Value = 29.235069 (C, atm, Hz, ...) 14:21:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.300727 V 14:21:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.300727 (V, A, ohm, ...), Measured Value = 97.554562 (C, atm, Hz, ...) 14:21:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084022 V 14:21:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084022 (V, A, ohm, ...), Measured Value = 6.301665 (C, atm, Hz, ...) 14:21:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000915 V 14:21:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000915 (V, A, ohm, ...), Measured Value = 0.914942 (C, atm, Hz, ...) 14:21:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.90 P3 = Right Coil Outgoing Side, Value = 28.57 P4 = Left Coil Middle, Value = 28.48 P5 = Ambient, Value = 24.65 P6 = Supply Temp(C), Value = 28.84 P7 = Return Temp(C), Value = 29.24 P8 = Supply Pres(psi), Value = 97.55 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.91 14:21:17 Magnetic Field Measurement Measuring the magnet strength... 14:21:17 Integrated Voltage Measurement... 14:21:20 Magnet Current for MAIN, Imag = 87.4701 A Vtrans = 0.874696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:21:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016779484 Vs 14:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773386 Vs 14:21:41 Magnet Current for MAIN, Imag = 87.4704 A Vtrans = 0.874699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:21:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781906 Vs 14:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772866 Vs 14:22:02 Magnet Current for MAIN, Imag = 87.4709 A Vtrans = 0.874704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:22:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781447 Vs 14:22:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771834 Vs 14:22:23 Magnet Current for MAIN, Imag = 87.4705 A Vtrans = 0.874700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:22:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780345 Vs 14:22:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771922 Vs 14:22:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776649 +- 0.000000462 Vs 14:22:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776649 +- 0.000000462 Vs BL = -0.18640721 +- 0.00000514 Tm 14:22:46 Position moved: 0.000000 m 14:22:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00001 -0.18641 0.00000 14:22:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00001 SL = -0.1864072 +- 0.0000051 Tm^2/m^n 14:22:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864072 +- 0.0000051 Tm^2/m^n 14:22:49 Position moved: 0.000000 m 14:22:49 Magnet system MAIN current ramping to 87.5000 A... 14:23:02 Magnet Current for MAIN, Imag = 87.4708 A Vtrans = 0.874703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:23:05 Main (V) Voltage Measurement, V = 3.121703 V 14:23:10 Temperature Measurement, Probe Number = 0, T = 26.910000 C 14:23:12 Temperature Measurement, Probe Number = 1, T = 28.608000 C 14:23:14 Temperature Measurement, Probe Number = 2, T = 28.588000 C 14:23:16 Temperature Measurement, Probe Number = 3, T = 24.654000 C 14:23:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356105 V 14:23:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356105 (V, A, ohm, ...), Measured Value = 28.834790 (C, atm, Hz, ...) 14:23:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.378756 V 14:23:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378756 (V, A, ohm, ...), Measured Value = 29.149387 (C, atm, Hz, ...) 14:23:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.305203 V 14:23:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.305203 (V, A, ohm, ...), Measured Value = 97.890240 (C, atm, Hz, ...) 14:23:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084025 V 14:23:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084025 (V, A, ohm, ...), Measured Value = 6.301853 (C, atm, Hz, ...) 14:23:32 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000907 V 14:23:32 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000907 (V, A, ohm, ...), Measured Value = 0.906678 (C, atm, Hz, ...) 14:23:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.91 P3 = Right Coil Outgoing Side, Value = 28.61 P4 = Left Coil Middle, Value = 28.59 P5 = Ambient, Value = 24.65 P6 = Supply Temp(C), Value = 28.83 P7 = Return Temp(C), Value = 29.15 P8 = Supply Pres(psi), Value = 97.89 P9 = Return Pres(psi), Value = 6.30 P10 = Flow Rate(gpm), Value = 0.91 14:23:32 Magnetic Field Measurement Measuring the magnet strength... 14:23:32 Integrated Voltage Measurement... 14:23:35 Magnet Current for MAIN, Imag = 87.4709 A Vtrans = 0.874704 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:23:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780314 Vs 14:23:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771010 Vs 14:23:57 Magnet Current for MAIN, Imag = 87.4706 A Vtrans = 0.874701 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:24:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016782062 Vs 14:24:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772989 Vs 14:24:17 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781265 Vs 14:24:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016774663 Vs 14:24:38 Magnet Current for MAIN, Imag = 87.4712 A Vtrans = 0.874706 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016780757 Vs 14:24:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016771463 Vs 14:24:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016776815 +- 0.000000955 Vs 14:24:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016776815 +- 0.000000955 Vs BL = -0.18640906 +- 0.00001061 Tm 14:25:00 Position moved: 0.000000 m 14:25:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18641 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18641 0.00001 -0.18641 0.00000 14:25:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18641 0.00001 SL = -0.1864091 +- 0.0000106 Tm^2/m^n 14:25:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864091 +- 0.0000106 Tm^2/m^n 14:25:04 Position moved: 0.000000 m 14:25:04 Magnet system MAIN current ramping to 87.5000 A... 14:25:17 Magnet Current for MAIN, Imag = 87.4708 A Vtrans = 0.874703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:25:19 Main (V) Voltage Measurement, V = 3.121706 V 14:25:24 Temperature Measurement, Probe Number = 0, T = 26.914000 C 14:25:27 Temperature Measurement, Probe Number = 1, T = 28.721000 C 14:25:29 Temperature Measurement, Probe Number = 2, T = 28.622000 C 14:25:31 Temperature Measurement, Probe Number = 3, T = 24.673000 C 14:25:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355801 V 14:25:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355801 (V, A, ohm, ...), Measured Value = 28.830574 (C, atm, Hz, ...) 14:25:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.383640 V 14:25:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.383640 (V, A, ohm, ...), Measured Value = 29.217219 (C, atm, Hz, ...) 14:25:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.312686 V 14:25:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.312686 (V, A, ohm, ...), Measured Value = 98.451458 (C, atm, Hz, ...) 14:25:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084138 V 14:25:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084138 (V, A, ohm, ...), Measured Value = 6.310380 (C, atm, Hz, ...) 14:25:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000927 V 14:25:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000927 (V, A, ohm, ...), Measured Value = 0.926985 (C, atm, Hz, ...) 14:25:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.12 P2 = Core, Value = 26.91 P3 = Right Coil Outgoing Side, Value = 28.72 P4 = Left Coil Middle, Value = 28.62 P5 = Ambient, Value = 24.67 P6 = Supply Temp(C), Value = 28.83 P7 = Return Temp(C), Value = 29.22 P8 = Supply Pres(psi), Value = 98.45 P9 = Return Pres(psi), Value = 6.31 P10 = Flow Rate(gpm), Value = 0.93 14:25:47 Magnetic Field Measurement Measuring the magnet strength... 14:25:47 Integrated Voltage Measurement... 14:25:49 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:26:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016778739 Vs 14:26:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772161 Vs 14:26:11 Magnet Current for MAIN, Imag = 87.4708 A Vtrans = 0.874703 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:26:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016781633 Vs 14:26:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773634 Vs 14:26:32 Magnet Current for MAIN, Imag = 87.4705 A Vtrans = 0.874700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:26:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016785291 Vs 14:26:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016772048 Vs 14:26:53 Magnet Current for MAIN, Imag = 87.4702 A Vtrans = 0.874697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:27:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016784521 Vs 14:27:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016773028 Vs 14:27:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016777632 +- 0.000001336 Vs 14:27:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016777632 +- 0.000001336 Vs BL = -0.18641813 +- 0.00001485 Tm 14:27:15 Position moved: 0.000000 m 14:27:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18642 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18642 0.00001 -0.18642 0.00000 14:27:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18642 0.00001 SL = -0.1864181 +- 0.0000148 Tm^2/m^n 14:27:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1864181 +- 0.0000148 Tm^2/m^n 14:27:18 Position moved: 0.000000 m 14:27:18 Magnet system MAIN current ramping to 75.0000 A... 14:27:38 Magnet Current for MAIN, Imag = 75.0226 A Vtrans = 0.750221 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:27:40 Main (V) Voltage Measurement, V = 2.677089 V 14:27:45 Temperature Measurement, Probe Number = 0, T = 26.922000 C 14:27:48 Temperature Measurement, Probe Number = 1, T = 28.716000 C 14:27:50 Temperature Measurement, Probe Number = 2, T = 28.643000 C 14:27:52 Temperature Measurement, Probe Number = 3, T = 24.672000 C 14:27:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356136 V 14:27:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356136 (V, A, ohm, ...), Measured Value = 28.835221 (C, atm, Hz, ...) 14:27:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.388026 V 14:27:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.388026 (V, A, ohm, ...), Measured Value = 29.278144 (C, atm, Hz, ...) 14:27:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.310990 V 14:27:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.310990 (V, A, ohm, ...), Measured Value = 98.324258 (C, atm, Hz, ...) 14:28:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084226 V 14:28:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084226 (V, A, ohm, ...), Measured Value = 6.316965 (C, atm, Hz, ...) 14:28:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 14:28:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.913147 (C, atm, Hz, ...) 14:28:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.92 P3 = Right Coil Outgoing Side, Value = 28.72 P4 = Left Coil Middle, Value = 28.64 P5 = Ambient, Value = 24.67 P6 = Supply Temp(C), Value = 28.84 P7 = Return Temp(C), Value = 29.28 P8 = Supply Pres(psi), Value = 98.32 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.91 14:28:08 Magnet system MAIN current ramping to 125.0000 A... 14:28:49 Magnet Current for MAIN, Imag = 124.9942 A Vtrans = 1.249937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:28:52 Main (V) Voltage Measurement, V = 4.465179 V 14:28:57 Temperature Measurement, Probe Number = 0, T = 26.913000 C 14:28:59 Temperature Measurement, Probe Number = 1, T = 28.739000 C 14:29:01 Temperature Measurement, Probe Number = 2, T = 28.625000 C 14:29:03 Temperature Measurement, Probe Number = 3, T = 24.681000 C 14:29:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355604 V 14:29:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355604 (V, A, ohm, ...), Measured Value = 28.827829 (C, atm, Hz, ...) 14:29:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389200 V 14:29:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389200 (V, A, ohm, ...), Measured Value = 29.294451 (C, atm, Hz, ...) 14:29:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.309976 V 14:29:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.309976 (V, A, ohm, ...), Measured Value = 98.248208 (C, atm, Hz, ...) 14:29:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084478 V 14:29:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084478 (V, A, ohm, ...), Measured Value = 6.335857 (C, atm, Hz, ...) 14:29:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 14:29:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907617 (C, atm, Hz, ...) 14:29:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.91 P3 = Right Coil Outgoing Side, Value = 28.74 P4 = Left Coil Middle, Value = 28.62 P5 = Ambient, Value = 24.68 P6 = Supply Temp(C), Value = 28.83 P7 = Return Temp(C), Value = 29.29 P8 = Supply Pres(psi), Value = 98.25 P9 = Return Pres(psi), Value = 6.34 P10 = Flow Rate(gpm), Value = 0.91 14:29:19 Magnet system MAIN current ramping to 0.0000 A... 14:30:43 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:30:45 Main (V) Voltage Measurement, V = -0.000001 V 14:30:50 Temperature Measurement, Probe Number = 0, T = 26.919000 C 14:30:53 Temperature Measurement, Probe Number = 1, T = 28.833000 C 14:30:55 Temperature Measurement, Probe Number = 2, T = 28.657000 C 14:30:57 Temperature Measurement, Probe Number = 3, T = 24.701000 C 14:30:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355051 V 14:30:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355051 (V, A, ohm, ...), Measured Value = 28.820150 (C, atm, Hz, ...) 14:31:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.394888 V 14:31:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.394888 (V, A, ohm, ...), Measured Value = 29.373442 (C, atm, Hz, ...) 14:31:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.311697 V 14:31:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.311697 (V, A, ohm, ...), Measured Value = 98.377245 (C, atm, Hz, ...) 14:31:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084390 V 14:31:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084390 (V, A, ohm, ...), Measured Value = 6.329272 (C, atm, Hz, ...) 14:31:13 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000902 V 14:31:13 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000902 (V, A, ohm, ...), Measured Value = 0.902460 (C, atm, Hz, ...) 14:31:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.92 P3 = Right Coil Outgoing Side, Value = 28.83 P4 = Left Coil Middle, Value = 28.66 P5 = Ambient, Value = 24.70 P6 = Supply Temp(C), Value = 28.82 P7 = Return Temp(C), Value = 29.37 P8 = Supply Pres(psi), Value = 98.38 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.90 14:31:13 Magnet system MAIN current ramping to 125.0000 A... 14:32:38 Magnet Current for MAIN, Imag = 124.9963 A Vtrans = 1.249958 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:32:40 Main (V) Voltage Measurement, V = 4.464888 V 14:32:45 Temperature Measurement, Probe Number = 0, T = 26.711000 C 14:32:47 Temperature Measurement, Probe Number = 1, T = 28.574000 C 14:32:49 Temperature Measurement, Probe Number = 2, T = 28.589000 C 14:32:51 Temperature Measurement, Probe Number = 3, T = 24.728000 C 14:32:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353984 V 14:32:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353984 (V, A, ohm, ...), Measured Value = 28.805332 (C, atm, Hz, ...) 14:32:55 Sensor Voltage Measurement, Sensor Number = 1, V = 2.390880 V 14:32:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.390880 (V, A, ohm, ...), Measured Value = 29.317774 (C, atm, Hz, ...) 14:32:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.311879 V 14:32:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.311879 (V, A, ohm, ...), Measured Value = 98.390910 (C, atm, Hz, ...) 14:33:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084408 V 14:33:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084408 (V, A, ohm, ...), Measured Value = 6.330630 (C, atm, Hz, ...) 14:33:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000909 V 14:33:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000909 (V, A, ohm, ...), Measured Value = 0.909044 (C, atm, Hz, ...) 14:33:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.46 P2 = Core, Value = 26.71 P3 = Right Coil Outgoing Side, Value = 28.57 P4 = Left Coil Middle, Value = 28.59 P5 = Ambient, Value = 24.73 P6 = Supply Temp(C), Value = 28.81 P7 = Return Temp(C), Value = 29.32 P8 = Supply Pres(psi), Value = 98.39 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.91 14:33:08 Magnet system MAIN current ramping to 0.0000 A... 14:34:32 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:34:34 Main (V) Voltage Measurement, V = 0.000001 V 14:34:39 Temperature Measurement, Probe Number = 0, T = 23.767000 C 14:34:41 Temperature Measurement, Probe Number = 1, T = 28.785000 C 14:34:44 Temperature Measurement, Probe Number = 2, T = 28.644000 C 14:34:46 Temperature Measurement, Probe Number = 3, T = 24.686000 C 14:34:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.353713 V 14:34:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353713 (V, A, ohm, ...), Measured Value = 28.801565 (C, atm, Hz, ...) 14:34:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.391039 V 14:34:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.391039 (V, A, ohm, ...), Measured Value = 29.319981 (C, atm, Hz, ...) 14:34:52 Sensor Voltage Measurement, Sensor Number = 2, V = 2.303831 V 14:34:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.303831 (V, A, ohm, ...), Measured Value = 97.787355 (C, atm, Hz, ...) 14:34:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084334 V 14:34:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084334 (V, A, ohm, ...), Measured Value = 6.325013 (C, atm, Hz, ...) 14:35:02 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000908 V 14:35:02 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000908 (V, A, ohm, ...), Measured Value = 0.907655 (C, atm, Hz, ...) 14:35:02 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 23.77 P3 = Right Coil Outgoing Side, Value = 28.79 P4 = Left Coil Middle, Value = 28.64 P5 = Ambient, Value = 24.69 P6 = Supply Temp(C), Value = 28.80 P7 = Return Temp(C), Value = 29.32 P8 = Supply Pres(psi), Value = 97.79 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.91 14:35:02 Magnet system MAIN current ramping to 125.0000 A... 14:36:26 Magnet Current for MAIN, Imag = 124.9946 A Vtrans = 1.249941 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:36:28 Main (V) Voltage Measurement, V = 4.464697 V 14:36:33 Temperature Measurement, Probe Number = 0, T = 24.156000 C 14:36:36 Temperature Measurement, Probe Number = 1, T = 28.602000 C 14:36:38 Temperature Measurement, Probe Number = 2, T = 28.552000 C 14:36:40 Temperature Measurement, Probe Number = 3, T = 24.714000 C 14:36:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.354069 V 14:36:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354069 (V, A, ohm, ...), Measured Value = 28.806517 (C, atm, Hz, ...) 14:36:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389083 V 14:36:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389083 (V, A, ohm, ...), Measured Value = 29.292819 (C, atm, Hz, ...) 14:36:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.304829 V 14:36:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.304829 (V, A, ohm, ...), Measured Value = 97.862145 (C, atm, Hz, ...) 14:36:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084401 V 14:36:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084401 (V, A, ohm, ...), Measured Value = 6.330045 (C, atm, Hz, ...) 14:36:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000905 V 14:36:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000905 (V, A, ohm, ...), Measured Value = 0.905374 (C, atm, Hz, ...) 14:36:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.46 P2 = Core, Value = 24.16 P3 = Right Coil Outgoing Side, Value = 28.60 P4 = Left Coil Middle, Value = 28.55 P5 = Ambient, Value = 24.71 P6 = Supply Temp(C), Value = 28.81 P7 = Return Temp(C), Value = 29.29 P8 = Supply Pres(psi), Value = 97.86 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.91 14:36:56 Magnet system MAIN current ramping to 0.0000 A... 14:38:20 Magnet Current for MAIN, Imag = -0.0001 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:38:22 Main (V) Voltage Measurement, V = -0.000004 V 14:38:28 Temperature Measurement, Probe Number = 0, T = 24.689000 C 14:38:30 Temperature Measurement, Probe Number = 1, T = 28.770000 C 14:38:32 Temperature Measurement, Probe Number = 2, T = 28.583000 C 14:38:34 Temperature Measurement, Probe Number = 3, T = 24.744000 C 14:38:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.354526 V 14:38:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354526 (V, A, ohm, ...), Measured Value = 28.812867 (C, atm, Hz, ...) 14:38:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389066 V 14:38:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389066 (V, A, ohm, ...), Measured Value = 29.292586 (C, atm, Hz, ...) 14:38:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.309731 V 14:38:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.309731 (V, A, ohm, ...), Measured Value = 98.229802 (C, atm, Hz, ...) 14:38:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084321 V 14:38:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084321 (V, A, ohm, ...), Measured Value = 6.324038 (C, atm, Hz, ...) 14:38:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000907 V 14:38:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000907 (V, A, ohm, ...), Measured Value = 0.907280 (C, atm, Hz, ...) 14:38:50 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 24.69 P3 = Right Coil Outgoing Side, Value = 28.77 P4 = Left Coil Middle, Value = 28.58 P5 = Ambient, Value = 24.74 P6 = Supply Temp(C), Value = 28.81 P7 = Return Temp(C), Value = 29.29 P8 = Supply Pres(psi), Value = 98.23 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.91 14:38:50 Magnet system MAIN current ramping to 125.0000 A... 14:40:14 Magnet Current for MAIN, Imag = 124.9949 A Vtrans = 1.249944 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:40:17 Main (V) Voltage Measurement, V = 4.465131 V 14:40:22 Temperature Measurement, Probe Number = 0, T = 26.813000 C 14:40:24 Temperature Measurement, Probe Number = 1, T = 28.589000 C 14:40:26 Temperature Measurement, Probe Number = 2, T = 28.541000 C 14:40:28 Temperature Measurement, Probe Number = 3, T = 24.755000 C 14:40:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.354661 V 14:40:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.354661 (V, A, ohm, ...), Measured Value = 28.814733 (C, atm, Hz, ...) 14:40:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.387723 V 14:40:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.387723 (V, A, ohm, ...), Measured Value = 29.273928 (C, atm, Hz, ...) 14:40:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.308172 V 14:40:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.308172 (V, A, ohm, ...), Measured Value = 98.112870 (C, atm, Hz, ...) 14:40:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084463 V 14:40:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084463 (V, A, ohm, ...), Measured Value = 6.334695 (C, atm, Hz, ...) 14:40:44 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000913 V 14:40:44 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000913 (V, A, ohm, ...), Measured Value = 0.912506 (C, atm, Hz, ...) 14:40:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 124.99 P1 = Main (V), Value = 4.47 P2 = Core, Value = 26.81 P3 = Right Coil Outgoing Side, Value = 28.59 P4 = Left Coil Middle, Value = 28.54 P5 = Ambient, Value = 24.75 P6 = Supply Temp(C), Value = 28.81 P7 = Return Temp(C), Value = 29.27 P8 = Supply Pres(psi), Value = 98.11 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.91 14:40:44 Magnet system MAIN current ramping to 0.0000 A... 14:42:09 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:42:11 Main (V) Voltage Measurement, V = -0.000003 V 14:42:16 Temperature Measurement, Probe Number = 0, T = 26.586000 C 14:42:18 Temperature Measurement, Probe Number = 1, T = 28.752000 C 14:42:21 Temperature Measurement, Probe Number = 2, T = 28.626000 C 14:42:23 Temperature Measurement, Probe Number = 3, T = 24.734000 C 14:42:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355251 V 14:42:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355251 (V, A, ohm, ...), Measured Value = 28.822932 (C, atm, Hz, ...) 14:42:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.389119 V 14:42:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.389119 (V, A, ohm, ...), Measured Value = 29.293321 (C, atm, Hz, ...) 14:42:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.307665 V 14:42:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.307665 (V, A, ohm, ...), Measured Value = 98.074898 (C, atm, Hz, ...) 14:42:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084390 V 14:42:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084390 (V, A, ohm, ...), Measured Value = 6.329272 (C, atm, Hz, ...) 14:42:39 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000912 V 14:42:39 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000912 (V, A, ohm, ...), Measured Value = 0.911532 (C, atm, Hz, ...) 14:42:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 26.59 P3 = Right Coil Outgoing Side, Value = 28.75 P4 = Left Coil Middle, Value = 28.63 P5 = Ambient, Value = 24.73 P6 = Supply Temp(C), Value = 28.82 P7 = Return Temp(C), Value = 29.29 P8 = Supply Pres(psi), Value = 98.07 P9 = Return Pres(psi), Value = 6.33 P10 = Flow Rate(gpm), Value = 0.91 14:42:39 Magnet system MAIN current ramping to 75.0000 A... 14:43:35 Magnet Current for MAIN, Imag = 75.0240 A Vtrans = 0.750235 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:43:37 Main (V) Voltage Measurement, V = 2.673892 V 14:43:42 Temperature Measurement, Probe Number = 0, T = 26.938000 C 14:43:44 Temperature Measurement, Probe Number = 1, T = 28.542000 C 14:43:46 Temperature Measurement, Probe Number = 2, T = 28.400000 C 14:43:48 Temperature Measurement, Probe Number = 3, T = 24.774000 C 14:43:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.355466 V 14:43:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355466 (V, A, ohm, ...), Measured Value = 28.825910 (C, atm, Hz, ...) 14:43:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.391236 V 14:43:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.391236 (V, A, ohm, ...), Measured Value = 29.322725 (C, atm, Hz, ...) 14:43:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.308274 V 14:43:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.308274 (V, A, ohm, ...), Measured Value = 98.120527 (C, atm, Hz, ...) 14:43:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084530 V 14:43:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084530 (V, A, ohm, ...), Measured Value = 6.339735 (C, atm, Hz, ...) 14:44:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000901 V 14:44:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000901 (V, A, ohm, ...), Measured Value = 0.900506 (C, atm, Hz, ...) 14:44:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.67 P2 = Core, Value = 26.94 P3 = Right Coil Outgoing Side, Value = 28.54 P4 = Left Coil Middle, Value = 28.40 P5 = Ambient, Value = 24.77 P6 = Supply Temp(C), Value = 28.83 P7 = Return Temp(C), Value = 29.32 P8 = Supply Pres(psi), Value = 98.12 P9 = Return Pres(psi), Value = 6.34 P10 = Flow Rate(gpm), Value = 0.90 14:44:05 Magnetic Field Measurement Measuring the magnet strength... 14:44:05 Integrated Voltage Measurement... 14:44:07 Magnet Current for MAIN, Imag = 75.0230 A Vtrans = 0.750225 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:44:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014405691 Vs 14:44:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399008 Vs 14:44:29 Magnet Current for MAIN, Imag = 75.0238 A Vtrans = 0.750232 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:44:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014410883 Vs 14:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014396628 Vs 14:44:49 Magnet Current for MAIN, Imag = 75.0238 A Vtrans = 0.750232 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:44:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014410003 Vs 14:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399122 Vs 14:45:10 Magnet Current for MAIN, Imag = 75.0235 A Vtrans = 0.750230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014411717 Vs 14:45:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014397290 Vs 14:45:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403793 +- 0.000000892 Vs 14:45:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403793 +- 0.000000892 Vs BL = -0.16004214 +- 0.00000991 Tm 14:45:33 Position moved: 0.000000 m 14:45:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 14:45:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600421 +- 0.0000099 Tm^2/m^n 14:45:33 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600421 +- 0.0000099 Tm^2/m^n 14:45:36 Position moved: 0.000000 m 14:45:36 Magnet system MAIN current ramping to 75.0000 A... 14:45:49 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:45:51 Main (V) Voltage Measurement, V = 2.675907 V 14:45:57 Temperature Measurement, Probe Number = 0, T = 26.970000 C 14:45:59 Temperature Measurement, Probe Number = 1, T = 28.472000 C 14:46:01 Temperature Measurement, Probe Number = 2, T = 28.495000 C 14:46:03 Temperature Measurement, Probe Number = 3, T = 24.785000 C 14:46:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356216 V 14:46:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356216 (V, A, ohm, ...), Measured Value = 28.836333 (C, atm, Hz, ...) 14:46:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.376852 V 14:46:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376852 (V, A, ohm, ...), Measured Value = 29.122944 (C, atm, Hz, ...) 14:46:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.308098 V 14:46:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.308098 (V, A, ohm, ...), Measured Value = 98.107350 (C, atm, Hz, ...) 14:46:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084146 V 14:46:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084146 (V, A, ohm, ...), Measured Value = 6.310965 (C, atm, Hz, ...) 14:46:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000915 V 14:46:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000915 (V, A, ohm, ...), Measured Value = 0.915334 (C, atm, Hz, ...) 14:46:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.97 P3 = Right Coil Outgoing Side, Value = 28.47 P4 = Left Coil Middle, Value = 28.50 P5 = Ambient, Value = 24.79 P6 = Supply Temp(C), Value = 28.84 P7 = Return Temp(C), Value = 29.12 P8 = Supply Pres(psi), Value = 98.11 P9 = Return Pres(psi), Value = 6.31 P10 = Flow Rate(gpm), Value = 0.92 14:46:19 Magnetic Field Measurement Measuring the magnet strength... 14:46:19 Integrated Voltage Measurement... 14:46:21 Magnet Current for MAIN, Imag = 75.0238 A Vtrans = 0.750232 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407790 Vs 14:46:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398446 Vs 14:46:43 Magnet Current for MAIN, Imag = 75.0236 A Vtrans = 0.750231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:46:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014410391 Vs 14:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398674 Vs 14:47:04 Magnet Current for MAIN, Imag = 75.0236 A Vtrans = 0.750231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:47:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014410778 Vs 14:47:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398810 Vs 14:47:25 Magnet Current for MAIN, Imag = 75.0240 A Vtrans = 0.750235 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408086 Vs 14:47:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014398647 Vs 14:47:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014403953 +- 0.000000722 Vs 14:47:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014403953 +- 0.000000722 Vs BL = -0.16004392 +- 0.00000802 Tm 14:47:48 Position moved: 0.000000 m 14:47:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16004 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16004 0.00001 -0.16004 0.00000 14:47:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16004 0.00001 SL = -0.1600439 +- 0.0000080 Tm^2/m^n 14:47:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600439 +- 0.0000080 Tm^2/m^n 14:47:51 Position moved: 0.000000 m 14:47:51 Magnet system MAIN current ramping to 75.0000 A... 14:48:04 Magnet Current for MAIN, Imag = 75.0236 A Vtrans = 0.750231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:48:07 Main (V) Voltage Measurement, V = 2.675957 V 14:48:12 Temperature Measurement, Probe Number = 0, T = 26.989000 C 14:48:14 Temperature Measurement, Probe Number = 1, T = 28.543000 C 14:48:16 Temperature Measurement, Probe Number = 2, T = 28.549000 C 14:48:18 Temperature Measurement, Probe Number = 3, T = 24.776000 C 14:48:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.356522 V 14:48:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.356522 (V, A, ohm, ...), Measured Value = 28.840585 (C, atm, Hz, ...) 14:48:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.375339 V 14:48:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375339 (V, A, ohm, ...), Measured Value = 29.101936 (C, atm, Hz, ...) 14:48:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.307251 V 14:48:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.307251 (V, A, ohm, ...), Measured Value = 98.043795 (C, atm, Hz, ...) 14:48:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.084278 V 14:48:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.084278 (V, A, ohm, ...), Measured Value = 6.320843 (C, atm, Hz, ...) 14:48:34 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000916 V 14:48:34 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000916 (V, A, ohm, ...), Measured Value = 0.916213 (C, atm, Hz, ...) 14:48:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.02 P1 = Main (V), Value = 2.68 P2 = Core, Value = 26.99 P3 = Right Coil Outgoing Side, Value = 28.54 P4 = Left Coil Middle, Value = 28.55 P5 = Ambient, Value = 24.78 P6 = Supply Temp(C), Value = 28.84 P7 = Return Temp(C), Value = 29.10 P8 = Supply Pres(psi), Value = 98.04 P9 = Return Pres(psi), Value = 6.32 P10 = Flow Rate(gpm), Value = 0.92 14:48:34 Magnetic Field Measurement Measuring the magnet strength... 14:48:34 Integrated Voltage Measurement... 14:48:37 Magnet Current for MAIN, Imag = 75.0235 A Vtrans = 0.750230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:48:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407298 Vs 14:48:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401556 Vs 14:48:59 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:49:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014409307 Vs 14:49:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014399547 Vs 14:49:20 Magnet Current for MAIN, Imag = 75.0233 A Vtrans = 0.750227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:49:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014408176 Vs 14:49:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014402244 Vs 14:49:40 Magnet Current for MAIN, Imag = 75.0234 A Vtrans = 0.750229 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000517 A 14:49:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014407665 Vs 14:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014401004 Vs 14:49:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014404600 +- 0.000000355 Vs 14:49:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014404600 +- 0.000000355 Vs BL = -0.16005111 +- 0.00000394 Tm 14:50:03 Position moved: 0.000000 m 14:50:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16005 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16005 0.00000 -0.16005 0.00000 14:50:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16005 0.00000 SL = -0.1600511 +- 0.0000039 Tm^2/m^n 14:50:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1600511 +- 0.0000039 Tm^2/m^n 14:50:06 Position moved: 0.000000 m 14:50:09 Position moved: 0.000000 m 14:50:12 Magnet system MAIN current ramping to 0.0000 A...