SLAC Magnetic Measurements Date: 09-26-2025 Time: 17:06:44 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4565 Serial Number: Run Number: 11 Measurement Device: 10wire Operator: sda Comment: On the Curve run for 87.5 and 75 amps. No Standardize after power supply is turned off Test Currents for MAIN (A): 87.50 125.00 0.00 75.00 17:07:09 Position moved: 0.000000 m 17:07:17 Magnet Current for MAIN, Imag = -0.0017 A Vtrans = -0.000017 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:19 Magnet Current for MAIN, Imag = -0.0014 A Vtrans = -0.000014 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:21 Magnet Current for MAIN, Imag = -0.0009 A Vtrans = -0.000009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:24 Magnet Current for MAIN, Imag = -0.0010 A Vtrans = -0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:07:24 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0013 +- 0.0003 A 17:07:47 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0012575 A 17:07:47 Ambient Measurement Device(s) Being Used, type = None 17:07:48 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 17:07:48 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:07:49 Ambient Measurement Device(s) Being Used, type = HP34970 17:07:52 Position moved: 0.000000 m 17:07:54 Magnet system MAIN current ramping to 87.5000 A... 17:08:56 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:08:59 Main (V) Voltage Measurement, V = 3.201422 V 17:09:07 Temperature Measurement, Probe Number = 0, T = 25.543000 C 17:09:09 Temperature Measurement, Probe Number = 1, T = 28.956000 C 17:09:11 Temperature Measurement, Probe Number = 2, T = 29.100000 C 17:09:13 Temperature Measurement, Probe Number = 3, T = 28.026000 C 17:09:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378449 V 17:09:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378449 (V, A, ohm, ...), Measured Value = 29.145118 (C, atm, Hz, ...) 17:09:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374881 V 17:09:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374881 (V, A, ohm, ...), Measured Value = 29.095567 (C, atm, Hz, ...) 17:09:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281111 V 17:09:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281111 (V, A, ohm, ...), Measured Value = 96.083295 (C, atm, Hz, ...) 17:09:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096944 V 17:09:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096944 (V, A, ohm, ...), Measured Value = 7.270815 (C, atm, Hz, ...) 17:09:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000888 V 17:09:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000888 (V, A, ohm, ...), Measured Value = 0.888163 (C, atm, Hz, ...) 17:09:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 25.54 P3 = Right Coil Outgoing Side, Value = 28.96 P4 = Left Coil Middle, Value = 29.10 P5 = Ambient, Value = 28.03 P6 = Supply Temp(C), Value = 29.15 P7 = Return Temp(C), Value = 29.10 P8 = Supply Pres(psi), Value = 96.08 P9 = Return Pres(psi), Value = 7.27 P10 = Flow Rate(gpm), Value = 0.89 17:09:30 Magnetic Field Measurement Measuring the magnet strength... 17:09:30 Integrated Voltage Measurement... 17:09:32 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:09:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016857169 Vs 17:09:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016842496 Vs 17:09:54 Magnet Current for MAIN, Imag = 87.4746 A Vtrans = 0.874734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:10:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016857694 Vs 17:10:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016842152 Vs 17:10:15 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:10:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016857237 Vs 17:10:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016841786 Vs 17:10:35 Magnet Current for MAIN, Imag = 87.4746 A Vtrans = 0.874734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:10:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016858033 Vs 17:10:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016841639 Vs 17:10:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016849776 +- 0.000000157 Vs 17:10:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016849776 +- 0.000000157 Vs BL = -0.18721973 +- 0.00000174 Tm 17:10:58 Position moved: 0.000000 m 17:10:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18722 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18722 0.00000 -0.18722 0.00000 17:10:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18722 0.00000 SL = -0.1872197 +- 0.0000017 Tm^2/m^n 17:10:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1872197 +- 0.0000017 Tm^2/m^n 17:11:01 Position moved: 0.000000 m 17:11:01 Magnet system MAIN current ramping to 125.0000 A... 17:11:35 Magnet Current for MAIN, Imag = 124.9993 A Vtrans = 1.249981 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:11:37 Main (V) Voltage Measurement, V = 4.593800 V 17:11:42 Temperature Measurement, Probe Number = 0, T = 20.736000 C 17:11:44 Temperature Measurement, Probe Number = 1, T = 29.346000 C 17:11:46 Temperature Measurement, Probe Number = 2, T = 29.421000 C 17:11:48 Temperature Measurement, Probe Number = 3, T = 28.000000 C 17:11:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378372 V 17:11:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378372 (V, A, ohm, ...), Measured Value = 29.144060 (C, atm, Hz, ...) 17:11:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.398853 V 17:11:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.398853 (V, A, ohm, ...), Measured Value = 29.428518 (C, atm, Hz, ...) 17:11:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278257 V 17:11:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278257 (V, A, ohm, ...), Measured Value = 95.869297 (C, atm, Hz, ...) 17:11:57 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097467 V 17:11:57 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097467 (V, A, ohm, ...), Measured Value = 7.310047 (C, atm, Hz, ...) 17:12:05 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000899 V 17:12:05 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000899 (V, A, ohm, ...), Measured Value = 0.898646 (C, atm, Hz, ...) 17:12:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = 20.74 P3 = Right Coil Outgoing Side, Value = 29.35 P4 = Left Coil Middle, Value = 29.42 P5 = Ambient, Value = 28.00 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.43 P8 = Supply Pres(psi), Value = 95.87 P9 = Return Pres(psi), Value = 7.31 P10 = Flow Rate(gpm), Value = 0.90 17:12:05 Magnet system MAIN current ramping to 0.0000 A... 17:13:28 Magnet Current for MAIN, Imag = -0.0000 A Vtrans = -0.000013 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:13:30 Main (V) Voltage Measurement, V = -0.000003 V 17:13:35 Temperature Measurement, Probe Number = 0, T = 20.728000 C 17:13:37 Temperature Measurement, Probe Number = 1, T = 29.637000 C 17:13:40 Temperature Measurement, Probe Number = 2, T = 29.488000 C 17:13:42 Temperature Measurement, Probe Number = 3, T = 27.978000 C 17:13:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378367 V 17:13:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378367 (V, A, ohm, ...), Measured Value = 29.143988 (C, atm, Hz, ...) 17:13:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.432233 V 17:13:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.432233 (V, A, ohm, ...), Measured Value = 29.892129 (C, atm, Hz, ...) 17:13:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275697 V 17:13:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275697 (V, A, ohm, ...), Measured Value = 95.677290 (C, atm, Hz, ...) 17:13:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097084 V 17:13:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097084 (V, A, ohm, ...), Measured Value = 7.281277 (C, atm, Hz, ...) 17:13:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000878 V 17:13:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000878 (V, A, ohm, ...), Measured Value = 0.878382 (C, atm, Hz, ...) 17:13:58 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 20.73 P3 = Right Coil Outgoing Side, Value = 29.64 P4 = Left Coil Middle, Value = 29.49 P5 = Ambient, Value = 27.98 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.89 P8 = Supply Pres(psi), Value = 95.68 P9 = Return Pres(psi), Value = 7.28 P10 = Flow Rate(gpm), Value = 0.88 17:13:58 Magnet system MAIN current ramping to 75.0000 A... 17:14:53 Magnet Current for MAIN, Imag = 75.0259 A Vtrans = 0.750247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:14:56 Main (V) Voltage Measurement, V = 2.744513 V 17:15:01 Temperature Measurement, Probe Number = 0, T = 23.772000 C 17:15:03 Temperature Measurement, Probe Number = 1, T = 29.438000 C 17:15:05 Temperature Measurement, Probe Number = 2, T = 29.287000 C 17:15:07 Temperature Measurement, Probe Number = 3, T = 27.998000 C 17:15:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378252 V 17:15:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378252 (V, A, ohm, ...), Measured Value = 29.142392 (C, atm, Hz, ...) 17:15:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.433853 V 17:15:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.433853 (V, A, ohm, ...), Measured Value = 29.914626 (C, atm, Hz, ...) 17:15:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284521 V 17:15:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284521 (V, A, ohm, ...), Measured Value = 96.339052 (C, atm, Hz, ...) 17:15:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097471 V 17:15:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097471 (V, A, ohm, ...), Measured Value = 7.310340 (C, atm, Hz, ...) 17:15:23 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 17:15:23 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.888734 (C, atm, Hz, ...) 17:15:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = 23.77 P3 = Right Coil Outgoing Side, Value = 29.44 P4 = Left Coil Middle, Value = 29.29 P5 = Ambient, Value = 28.00 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.91 P8 = Supply Pres(psi), Value = 96.34 P9 = Return Pres(psi), Value = 7.31 P10 = Flow Rate(gpm), Value = 0.89 17:15:23 Magnetic Field Measurement Measuring the magnet strength... 17:15:23 Integrated Voltage Measurement... 17:15:26 Magnet Current for MAIN, Imag = 75.0257 A Vtrans = 0.750244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:15:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475333 Vs 17:15:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461077 Vs 17:15:48 Magnet Current for MAIN, Imag = 75.0264 A Vtrans = 0.750252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:15:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474678 Vs 17:16:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460629 Vs 17:16:08 Magnet Current for MAIN, Imag = 75.0261 A Vtrans = 0.750248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475359 Vs 17:16:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459826 Vs 17:16:29 Magnet Current for MAIN, Imag = 75.0261 A Vtrans = 0.750248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:16:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474098 Vs 17:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460460 Vs 17:16:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014467682 +- 0.000000333 Vs 17:16:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014467682 +- 0.000000333 Vs BL = -0.16075203 +- 0.00000371 Tm 17:16:52 Position moved: 0.000000 m 17:16:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16075 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16075 0.00000 -0.16075 0.00000 17:16:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16075 0.00000 SL = -0.1607520 +- 0.0000037 Tm^2/m^n 17:16:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607520 +- 0.0000037 Tm^2/m^n 17:16:55 Position moved: 0.000000 m 17:16:57 Position moved: 0.000000 m 17:17:00 Magnet system MAIN current ramping to 87.5000 A... 17:17:20 Magnet Current for MAIN, Imag = 87.4745 A Vtrans = 0.874732 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:17:22 Main (V) Voltage Measurement, V = 3.204413 V 17:17:27 Temperature Measurement, Probe Number = 0, T = 24.772000 C 17:17:29 Temperature Measurement, Probe Number = 1, T = 29.385000 C 17:17:32 Temperature Measurement, Probe Number = 2, T = 29.336000 C 17:17:34 Temperature Measurement, Probe Number = 3, T = 28.019000 C 17:17:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378111 V 17:17:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378111 (V, A, ohm, ...), Measured Value = 29.140436 (C, atm, Hz, ...) 17:17:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.412986 V 17:17:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.412986 (V, A, ohm, ...), Measured Value = 29.624803 (C, atm, Hz, ...) 17:17:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.272769 V 17:17:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.272769 (V, A, ohm, ...), Measured Value = 95.457667 (C, atm, Hz, ...) 17:17:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097339 V 17:17:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097339 (V, A, ohm, ...), Measured Value = 7.300462 (C, atm, Hz, ...) 17:17:50 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 17:17:50 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890911 (C, atm, Hz, ...) 17:17:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 24.77 P3 = Right Coil Outgoing Side, Value = 29.39 P4 = Left Coil Middle, Value = 29.34 P5 = Ambient, Value = 28.02 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.62 P8 = Supply Pres(psi), Value = 95.46 P9 = Return Pres(psi), Value = 7.30 P10 = Flow Rate(gpm), Value = 0.89 17:17:50 Magnetic Field Measurement Measuring the magnet strength... 17:17:50 Integrated Voltage Measurement... 17:17:52 Magnet Current for MAIN, Imag = 87.4746 A Vtrans = 0.874734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:18:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866547 Vs 17:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852317 Vs 17:18:14 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:18:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866031 Vs 17:18:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016851391 Vs 17:18:35 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016867186 Vs 17:18:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852372 Vs 17:18:55 Magnet Current for MAIN, Imag = 87.4745 A Vtrans = 0.874732 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:19:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016867200 Vs 17:19:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852014 Vs 17:19:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016859382 +- 0.000000406 Vs 17:19:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016859382 +- 0.000000406 Vs BL = -0.18732647 +- 0.00000452 Tm 17:19:18 Position moved: 0.000000 m 17:19:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18733 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18733 0.00000 -0.18733 0.00000 17:19:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18733 0.00000 SL = -0.1873265 +- 0.0000045 Tm^2/m^n 17:19:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1873265 +- 0.0000045 Tm^2/m^n 17:19:21 Position moved: 0.000000 m 17:19:21 Magnet system MAIN current ramping to 125.0000 A... 17:19:55 Magnet Current for MAIN, Imag = 124.9991 A Vtrans = 1.249978 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:19:57 Main (V) Voltage Measurement, V = 4.594001 V 17:20:02 Temperature Measurement, Probe Number = 0, T = 25.066000 C 17:20:05 Temperature Measurement, Probe Number = 1, T = 29.555000 C 17:20:07 Temperature Measurement, Probe Number = 2, T = 29.493000 C 17:20:09 Temperature Measurement, Probe Number = 3, T = 28.041000 C 17:20:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378145 V 17:20:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378145 (V, A, ohm, ...), Measured Value = 29.140901 (C, atm, Hz, ...) 17:20:13 Sensor Voltage Measurement, Sensor Number = 1, V = 2.422431 V 17:20:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.422431 (V, A, ohm, ...), Measured Value = 29.755982 (C, atm, Hz, ...) 17:20:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.270998 V 17:20:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.270998 (V, A, ohm, ...), Measured Value = 95.324850 (C, atm, Hz, ...) 17:20:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097735 V 17:20:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097735 (V, A, ohm, ...), Measured Value = 7.330102 (C, atm, Hz, ...) 17:20:25 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000870 V 17:20:25 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000870 (V, A, ohm, ...), Measured Value = 0.870038 (C, atm, Hz, ...) 17:20:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = 25.07 P3 = Right Coil Outgoing Side, Value = 29.55 P4 = Left Coil Middle, Value = 29.49 P5 = Ambient, Value = 28.04 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.76 P8 = Supply Pres(psi), Value = 95.32 P9 = Return Pres(psi), Value = 7.33 P10 = Flow Rate(gpm), Value = 0.87 17:20:25 Magnet system MAIN current ramping to 0.0000 A... 17:21:49 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000012 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:21:51 Main (V) Voltage Measurement, V = -0.000005 V 17:21:56 Temperature Measurement, Probe Number = 0, T = 24.129000 C 17:21:58 Temperature Measurement, Probe Number = 1, T = 29.719000 C 17:22:01 Temperature Measurement, Probe Number = 2, T = 29.514000 C 17:22:03 Temperature Measurement, Probe Number = 3, T = 28.014000 C 17:22:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377998 V 17:22:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377998 (V, A, ohm, ...), Measured Value = 29.138857 (C, atm, Hz, ...) 17:22:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.442120 V 17:22:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.442120 (V, A, ohm, ...), Measured Value = 30.029443 (C, atm, Hz, ...) 17:22:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275972 V 17:22:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275972 (V, A, ohm, ...), Measured Value = 95.697922 (C, atm, Hz, ...) 17:22:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097603 V 17:22:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097603 (V, A, ohm, ...), Measured Value = 7.320225 (C, atm, Hz, ...) 17:22:19 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000872 V 17:22:19 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000872 (V, A, ohm, ...), Measured Value = 0.871731 (C, atm, Hz, ...) 17:22:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 24.13 P3 = Right Coil Outgoing Side, Value = 29.72 P4 = Left Coil Middle, Value = 29.51 P5 = Ambient, Value = 28.01 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 30.03 P8 = Supply Pres(psi), Value = 95.70 P9 = Return Pres(psi), Value = 7.32 P10 = Flow Rate(gpm), Value = 0.87 17:22:19 Magnet system MAIN current ramping to 75.0000 A... 17:23:15 Magnet Current for MAIN, Imag = 75.0262 A Vtrans = 0.750249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:23:17 Main (V) Voltage Measurement, V = 2.744413 V 17:23:22 Temperature Measurement, Probe Number = 0, T = 22.731000 C 17:23:24 Temperature Measurement, Probe Number = 1, T = 29.458000 C 17:23:26 Temperature Measurement, Probe Number = 2, T = 29.290000 C 17:23:28 Temperature Measurement, Probe Number = 3, T = 28.030000 C 17:23:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.378012 V 17:23:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378012 (V, A, ohm, ...), Measured Value = 29.139054 (C, atm, Hz, ...) 17:23:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.439804 V 17:23:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.439804 (V, A, ohm, ...), Measured Value = 29.997276 (C, atm, Hz, ...) 17:23:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.278610 V 17:23:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.278610 (V, A, ohm, ...), Measured Value = 95.895743 (C, atm, Hz, ...) 17:23:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097819 V 17:23:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097819 (V, A, ohm, ...), Measured Value = 7.336402 (C, atm, Hz, ...) 17:23:45 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 17:23:45 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886054 (C, atm, Hz, ...) 17:23:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = 22.73 P3 = Right Coil Outgoing Side, Value = 29.46 P4 = Left Coil Middle, Value = 29.29 P5 = Ambient, Value = 28.03 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 30.00 P8 = Supply Pres(psi), Value = 95.90 P9 = Return Pres(psi), Value = 7.34 P10 = Flow Rate(gpm), Value = 0.89 17:23:45 Magnetic Field Measurement Measuring the magnet strength... 17:23:45 Integrated Voltage Measurement... 17:23:47 Magnet Current for MAIN, Imag = 75.0258 A Vtrans = 0.750246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474935 Vs 17:24:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459340 Vs 17:24:09 Magnet Current for MAIN, Imag = 75.0262 A Vtrans = 0.750249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:24:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475731 Vs 17:24:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460153 Vs 17:24:30 Magnet Current for MAIN, Imag = 75.0261 A Vtrans = 0.750248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:24:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474791 Vs 17:24:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459941 Vs 17:24:50 Magnet Current for MAIN, Imag = 75.0266 A Vtrans = 0.750253 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:25:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475087 Vs 17:25:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461439 Vs 17:25:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014467677 +- 0.000000448 Vs 17:25:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014467677 +- 0.000000448 Vs BL = -0.16075197 +- 0.00000498 Tm 17:25:13 Position moved: 0.000000 m 17:25:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16075 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16075 0.00000 -0.16075 0.00000 17:25:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16075 0.00000 SL = -0.1607520 +- 0.0000050 Tm^2/m^n 17:25:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607520 +- 0.0000050 Tm^2/m^n 17:25:16 Position moved: 0.000000 m 17:25:19 Position moved: 0.000000 m 17:25:22 Magnet system MAIN current ramping to 87.5000 A... 17:25:42 Magnet Current for MAIN, Imag = 87.4742 A Vtrans = 0.874730 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:25:44 Main (V) Voltage Measurement, V = 3.204391 V 17:25:49 Temperature Measurement, Probe Number = 0, T = 22.508000 C 17:25:51 Temperature Measurement, Probe Number = 1, T = 29.373000 C 17:25:53 Temperature Measurement, Probe Number = 2, T = 29.330000 C 17:25:55 Temperature Measurement, Probe Number = 3, T = 28.044000 C 17:25:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377787 V 17:25:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377787 (V, A, ohm, ...), Measured Value = 29.135932 (C, atm, Hz, ...) 17:26:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.415551 V 17:26:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.415551 (V, A, ohm, ...), Measured Value = 29.660432 (C, atm, Hz, ...) 17:26:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274442 V 17:26:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274442 (V, A, ohm, ...), Measured Value = 95.583128 (C, atm, Hz, ...) 17:26:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097574 V 17:26:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097574 (V, A, ohm, ...), Measured Value = 7.318087 (C, atm, Hz, ...) 17:26:12 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000903 V 17:26:12 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000903 (V, A, ohm, ...), Measured Value = 0.903095 (C, atm, Hz, ...) 17:26:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 22.51 P3 = Right Coil Outgoing Side, Value = 29.37 P4 = Left Coil Middle, Value = 29.33 P5 = Ambient, Value = 28.04 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.66 P8 = Supply Pres(psi), Value = 95.58 P9 = Return Pres(psi), Value = 7.32 P10 = Flow Rate(gpm), Value = 0.90 17:26:12 Magnetic Field Measurement Measuring the magnet strength... 17:26:12 Integrated Voltage Measurement... 17:26:14 Magnet Current for MAIN, Imag = 87.4743 A Vtrans = 0.874731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:26:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016865462 Vs 17:26:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016853111 Vs 17:26:36 Magnet Current for MAIN, Imag = 87.4745 A Vtrans = 0.874732 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:26:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866318 Vs 17:26:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852465 Vs 17:26:56 Magnet Current for MAIN, Imag = 87.4746 A Vtrans = 0.874734 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:27:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016867321 Vs 17:27:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852456 Vs 17:27:17 Magnet Current for MAIN, Imag = 87.4745 A Vtrans = 0.874732 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:27:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016865460 Vs 17:27:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852514 Vs 17:27:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016859388 +- 0.000000325 Vs 17:27:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016859388 +- 0.000000325 Vs BL = -0.18732654 +- 0.00000361 Tm 17:27:40 Position moved: 0.000000 m 17:27:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18733 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18733 0.00000 -0.18733 0.00000 17:27:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18733 0.00000 SL = -0.1873265 +- 0.0000036 Tm^2/m^n 17:27:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1873265 +- 0.0000036 Tm^2/m^n 17:27:43 Position moved: 0.000000 m 17:27:43 Magnet system MAIN current ramping to 125.0000 A... 17:28:17 Magnet Current for MAIN, Imag = 124.9990 A Vtrans = 1.249977 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:28:19 Main (V) Voltage Measurement, V = 4.593968 V 17:28:24 Temperature Measurement, Probe Number = 0, T = 25.680000 C 17:28:26 Temperature Measurement, Probe Number = 1, T = 29.549000 C 17:28:28 Temperature Measurement, Probe Number = 2, T = 29.490000 C 17:28:30 Temperature Measurement, Probe Number = 3, T = 28.051000 C 17:28:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377765 V 17:28:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377765 (V, A, ohm, ...), Measured Value = 29.135628 (C, atm, Hz, ...) 17:28:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.424070 V 17:28:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.424070 (V, A, ohm, ...), Measured Value = 29.778747 (C, atm, Hz, ...) 17:28:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.284448 V 17:28:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.284448 (V, A, ohm, ...), Measured Value = 96.333630 (C, atm, Hz, ...) 17:28:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097932 V 17:28:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097932 (V, A, ohm, ...), Measured Value = 7.344923 (C, atm, Hz, ...) 17:28:47 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 17:28:47 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886088 (C, atm, Hz, ...) 17:28:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = 25.68 P3 = Right Coil Outgoing Side, Value = 29.55 P4 = Left Coil Middle, Value = 29.49 P5 = Ambient, Value = 28.05 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 29.78 P8 = Supply Pres(psi), Value = 96.33 P9 = Return Pres(psi), Value = 7.34 P10 = Flow Rate(gpm), Value = 0.89 17:28:47 Magnet system MAIN current ramping to 0.0000 A... 17:30:10 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:30:12 Main (V) Voltage Measurement, V = -0.000005 V 17:30:17 Temperature Measurement, Probe Number = 0, T = 27.329000 C 17:30:19 Temperature Measurement, Probe Number = 1, T = 29.735000 C 17:30:22 Temperature Measurement, Probe Number = 2, T = 29.527000 C 17:30:24 Temperature Measurement, Probe Number = 3, T = 28.060000 C 17:30:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377658 V 17:30:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377658 (V, A, ohm, ...), Measured Value = 29.134139 (C, atm, Hz, ...) 17:30:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.442696 V 17:30:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.442696 (V, A, ohm, ...), Measured Value = 30.037444 (C, atm, Hz, ...) 17:30:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283331 V 17:30:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283331 (V, A, ohm, ...), Measured Value = 96.249832 (C, atm, Hz, ...) 17:30:32 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097914 V 17:30:32 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097914 (V, A, ohm, ...), Measured Value = 7.343573 (C, atm, Hz, ...) 17:30:40 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000887 V 17:30:40 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000887 (V, A, ohm, ...), Measured Value = 0.887344 (C, atm, Hz, ...) 17:30:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 27.33 P3 = Right Coil Outgoing Side, Value = 29.73 P4 = Left Coil Middle, Value = 29.53 P5 = Ambient, Value = 28.06 P6 = Supply Temp(C), Value = 29.13 P7 = Return Temp(C), Value = 30.04 P8 = Supply Pres(psi), Value = 96.25 P9 = Return Pres(psi), Value = 7.34 P10 = Flow Rate(gpm), Value = 0.89 17:30:40 Magnet system MAIN current ramping to 75.0000 A... 17:31:35 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:31:37 Main (V) Voltage Measurement, V = 2.744374 V 17:31:46 Temperature Measurement, Probe Number = 0, T = -4.023000 C 17:31:48 Temperature Measurement, Probe Number = 1, T = 29.484000 C 17:31:50 Temperature Measurement, Probe Number = 2, T = 29.304000 C 17:31:52 Temperature Measurement, Probe Number = 3, T = 28.048000 C 17:31:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377769 V 17:31:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377769 (V, A, ohm, ...), Measured Value = 29.135682 (C, atm, Hz, ...) 17:31:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.440278 V 17:31:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.440278 (V, A, ohm, ...), Measured Value = 30.003860 (C, atm, Hz, ...) 17:31:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.279497 V 17:31:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.279497 (V, A, ohm, ...), Measured Value = 95.962298 (C, atm, Hz, ...) 17:32:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.098174 V 17:32:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.098174 (V, A, ohm, ...), Measured Value = 7.363042 (C, atm, Hz, ...) 17:32:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 17:32:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895859 (C, atm, Hz, ...) 17:32:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = -4.02 P3 = Right Coil Outgoing Side, Value = 29.48 P4 = Left Coil Middle, Value = 29.30 P5 = Ambient, Value = 28.05 P6 = Supply Temp(C), Value = 29.14 P7 = Return Temp(C), Value = 30.00 P8 = Supply Pres(psi), Value = 95.96 P9 = Return Pres(psi), Value = 7.36 P10 = Flow Rate(gpm), Value = 0.90 17:32:08 Magnetic Field Measurement Measuring the magnet strength... 17:32:08 Integrated Voltage Measurement... 17:32:11 Magnet Current for MAIN, Imag = 75.0257 A Vtrans = 0.750244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:32:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475784 Vs 17:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461011 Vs 17:32:32 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:32:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014476798 Vs 17:32:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460148 Vs 17:32:53 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:33:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474499 Vs 17:33:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461348 Vs 17:33:14 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.001257 A 17:33:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475426 Vs 17:33:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461901 Vs 17:33:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014468364 +- 0.000000273 Vs 17:33:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014468364 +- 0.000000273 Vs BL = -0.16075960 +- 0.00000303 Tm 17:33:36 Position moved: 0.000000 m 17:33:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16076 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16076 0.00000 -0.16076 0.00000 17:33:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16076 0.00000 SL = -0.1607596 +- 0.0000030 Tm^2/m^n 17:33:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607596 +- 0.0000030 Tm^2/m^n 17:33:39 Position moved: 0.000000 m 17:33:42 Position moved: 0.000000 m 17:33:45 Magnet system MAIN current ramping to 0.0000 A...