SLAC Magnetic Measurements Date: 09-26-2025 Time: 16:25:33 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4565 Serial Number: Run Number: 10 Measurement Device: 10wire Operator: sda Comment: On the Curve run for 87.5 and 75 amps. Standardize first, after power supply is turned off Standardization for MAIN: 3 cycles from 0.0 A to 125.0 A to 0.0 A Test Currents for MAIN (A): 87.50 125.00 0.00 75.00 16:25:59 Position moved: 0.000000 m 16:26:03 Magnet Current for MAIN, Imag = -0.0013 A Vtrans = -0.000013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:06 Magnet Current for MAIN, Imag = -0.0008 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:08 Magnet Current for MAIN, Imag = -0.0008 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:10 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = -0.000006 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 16:26:10 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0009 +- 0.0002 A 16:26:48 Initial Zero Current Measurement for MAIN, Imag_zero = -0.000875 A 16:26:48 Ambient Measurement Device(s) Being Used, type = None 16:26:49 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 16:26:49 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 16:26:50 Ambient Measurement Device(s) Being Used, type = HP34970 16:26:50 Magnet system MAIN current ramping to 125.0000 A... 16:28:11 Magnet system MAIN current ramping to 0.0000 A... 16:29:32 Magnet system MAIN current ramping to 125.0000 A... 16:30:53 Magnet system MAIN current ramping to 0.0000 A... 16:32:14 Magnet system MAIN current ramping to 125.0000 A... 16:33:35 Magnet system MAIN current ramping to 0.0000 A... 16:34:59 Position moved: 0.000000 m 16:35:02 Magnet system MAIN current ramping to 87.5000 A... 16:36:04 Magnet Current for MAIN, Imag = 87.4733 A Vtrans = 0.874725 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:36:06 Main (V) Voltage Measurement, V = 3.202186 V 16:36:14 Temperature Measurement, Probe Number = 0, T = 25.961000 C 16:36:16 Temperature Measurement, Probe Number = 1, T = 29.269000 C 16:36:18 Temperature Measurement, Probe Number = 2, T = 29.230000 C 16:36:21 Temperature Measurement, Probe Number = 3, T = 27.893000 C 16:36:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.371609 V 16:36:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.371609 (V, A, ohm, ...), Measured Value = 29.050125 (C, atm, Hz, ...) 16:36:25 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402033 V 16:36:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402033 (V, A, ohm, ...), Measured Value = 29.472686 (C, atm, Hz, ...) 16:36:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271451 V 16:36:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271451 (V, A, ohm, ...), Measured Value = 95.358855 (C, atm, Hz, ...) 16:36:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095579 V 16:36:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095579 (V, A, ohm, ...), Measured Value = 7.168418 (C, atm, Hz, ...) 16:36:37 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000902 V 16:36:37 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000902 (V, A, ohm, ...), Measured Value = 0.901827 (C, atm, Hz, ...) 16:36:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 25.96 P3 = Right Coil Outgoing Side, Value = 29.27 P4 = Left Coil Middle, Value = 29.23 P5 = Ambient, Value = 27.89 P6 = Supply Temp(C), Value = 29.05 P7 = Return Temp(C), Value = 29.47 P8 = Supply Pres(psi), Value = 95.36 P9 = Return Pres(psi), Value = 7.17 P10 = Flow Rate(gpm), Value = 0.90 16:36:37 Magnetic Field Measurement Measuring the magnet strength... 16:36:37 Integrated Voltage Measurement... 16:36:39 Magnet Current for MAIN, Imag = 87.4734 A Vtrans = 0.874726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:36:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016861724 Vs 16:36:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016845603 Vs 16:37:01 Magnet Current for MAIN, Imag = 87.4732 A Vtrans = 0.874723 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:37:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016861432 Vs 16:37:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016846490 Vs 16:37:22 Magnet Current for MAIN, Imag = 87.4732 A Vtrans = 0.874723 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:37:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016860314 Vs 16:37:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016845075 Vs 16:37:42 Magnet Current for MAIN, Imag = 87.4733 A Vtrans = 0.874725 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:37:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016860497 Vs 16:38:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016845538 Vs 16:38:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016853334 +- 0.000000503 Vs 16:38:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016853334 +- 0.000000503 Vs BL = -0.18725927 +- 0.00000558 Tm 16:38:05 Position moved: 0.000000 m 16:38:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18726 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18726 0.00001 -0.18726 0.00000 16:38:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18726 0.00001 SL = -0.1872593 +- 0.0000056 Tm^2/m^n 16:38:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1872593 +- 0.0000056 Tm^2/m^n 16:38:08 Position moved: 0.000000 m 16:38:08 Magnet system MAIN current ramping to 125.0000 A... 16:38:42 Magnet Current for MAIN, Imag = 124.9981 A Vtrans = 1.249972 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:38:44 Main (V) Voltage Measurement, V = 4.592933 V 16:38:52 Temperature Measurement, Probe Number = 0, T = -0.206000 C 16:38:54 Temperature Measurement, Probe Number = 1, T = 29.419000 C 16:38:57 Temperature Measurement, Probe Number = 2, T = 29.390000 C 16:38:59 Temperature Measurement, Probe Number = 3, T = 27.891000 C 16:39:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.372717 V 16:39:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372717 (V, A, ohm, ...), Measured Value = 29.065518 (C, atm, Hz, ...) 16:39:03 Sensor Voltage Measurement, Sensor Number = 1, V = 2.403563 V 16:39:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.403563 (V, A, ohm, ...), Measured Value = 29.493928 (C, atm, Hz, ...) 16:39:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.285648 V 16:39:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.285648 (V, A, ohm, ...), Measured Value = 96.423623 (C, atm, Hz, ...) 16:39:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095813 V 16:39:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095813 (V, A, ohm, ...), Measured Value = 7.185952 (C, atm, Hz, ...) 16:39:15 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 16:39:15 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896044 (C, atm, Hz, ...) 16:39:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = -0.21 P3 = Right Coil Outgoing Side, Value = 29.42 P4 = Left Coil Middle, Value = 29.39 P5 = Ambient, Value = 27.89 P6 = Supply Temp(C), Value = 29.07 P7 = Return Temp(C), Value = 29.49 P8 = Supply Pres(psi), Value = 96.42 P9 = Return Pres(psi), Value = 7.19 P10 = Flow Rate(gpm), Value = 0.90 16:39:15 Magnet system MAIN current ramping to 0.0000 A... 16:40:38 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = -0.000013 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:40:40 Main (V) Voltage Measurement, V = -0.000005 V 16:40:46 Temperature Measurement, Probe Number = 0, T = 13.810000 C 16:40:48 Temperature Measurement, Probe Number = 1, T = 29.627000 C 16:40:50 Temperature Measurement, Probe Number = 2, T = 29.428000 C 16:40:52 Temperature Measurement, Probe Number = 3, T = 27.893000 C 16:40:54 Sensor Voltage Measurement, Sensor Number = 0, V = 2.373215 V 16:40:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373215 (V, A, ohm, ...), Measured Value = 29.072425 (C, atm, Hz, ...) 16:40:56 Sensor Voltage Measurement, Sensor Number = 1, V = 2.427246 V 16:40:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.427246 (V, A, ohm, ...), Measured Value = 29.822862 (C, atm, Hz, ...) 16:40:58 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283584 V 16:40:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283584 (V, A, ohm, ...), Measured Value = 96.268815 (C, atm, Hz, ...) 16:41:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095645 V 16:41:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095645 (V, A, ohm, ...), Measured Value = 7.173360 (C, atm, Hz, ...) 16:41:08 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 16:41:08 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.896310 (C, atm, Hz, ...) 16:41:08 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 13.81 P3 = Right Coil Outgoing Side, Value = 29.63 P4 = Left Coil Middle, Value = 29.43 P5 = Ambient, Value = 27.89 P6 = Supply Temp(C), Value = 29.07 P7 = Return Temp(C), Value = 29.82 P8 = Supply Pres(psi), Value = 96.27 P9 = Return Pres(psi), Value = 7.17 P10 = Flow Rate(gpm), Value = 0.90 16:41:08 Magnet system MAIN current ramping to 75.0000 A... 16:42:04 Magnet Current for MAIN, Imag = 75.0253 A Vtrans = 0.750244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:42:06 Main (V) Voltage Measurement, V = 2.743929 V 16:42:11 Temperature Measurement, Probe Number = 0, T = 10.811000 C 16:42:13 Temperature Measurement, Probe Number = 1, T = 29.394000 C 16:42:15 Temperature Measurement, Probe Number = 2, T = 29.226000 C 16:42:17 Temperature Measurement, Probe Number = 3, T = 27.902000 C 16:42:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.373461 V 16:42:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.373461 (V, A, ohm, ...), Measured Value = 29.075851 (C, atm, Hz, ...) 16:42:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.426915 V 16:42:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.426915 (V, A, ohm, ...), Measured Value = 29.818269 (C, atm, Hz, ...) 16:42:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.286458 V 16:42:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.286458 (V, A, ohm, ...), Measured Value = 96.484365 (C, atm, Hz, ...) 16:42:26 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095965 V 16:42:26 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095965 (V, A, ohm, ...), Measured Value = 7.197382 (C, atm, Hz, ...) 16:42:34 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000889 V 16:42:34 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000889 (V, A, ohm, ...), Measured Value = 0.888540 (C, atm, Hz, ...) 16:42:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = 10.81 P3 = Right Coil Outgoing Side, Value = 29.39 P4 = Left Coil Middle, Value = 29.23 P5 = Ambient, Value = 27.90 P6 = Supply Temp(C), Value = 29.08 P7 = Return Temp(C), Value = 29.82 P8 = Supply Pres(psi), Value = 96.48 P9 = Return Pres(psi), Value = 7.20 P10 = Flow Rate(gpm), Value = 0.89 16:42:34 Magnetic Field Measurement Measuring the magnet strength... 16:42:34 Integrated Voltage Measurement... 16:42:36 Magnet Current for MAIN, Imag = 75.0254 A Vtrans = 0.750246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:42:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475403 Vs 16:42:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459916 Vs 16:42:58 Magnet Current for MAIN, Imag = 75.0252 A Vtrans = 0.750243 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:43:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475357 Vs 16:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460318 Vs 16:43:19 Magnet Current for MAIN, Imag = 75.0256 A Vtrans = 0.750247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475345 Vs 16:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460071 Vs 16:43:40 Magnet Current for MAIN, Imag = 75.0253 A Vtrans = 0.750244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:43:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474468 Vs 16:43:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459925 Vs 16:43:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014467600 +- 0.000000242 Vs 16:43:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014467600 +- 0.000000242 Vs BL = -0.16075111 +- 0.00000269 Tm 16:44:02 Position moved: 0.000000 m 16:44:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16075 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16075 0.00000 -0.16075 0.00000 16:44:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16075 0.00000 SL = -0.1607511 +- 0.0000027 Tm^2/m^n 16:44:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607511 +- 0.0000027 Tm^2/m^n 16:44:05 Position moved: 0.000000 m 16:44:08 Position moved: 0.000000 m 16:44:10 Magnet system MAIN current ramping to 87.5000 A... 16:44:31 Magnet Current for MAIN, Imag = 87.4737 A Vtrans = 0.874728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:44:33 Main (V) Voltage Measurement, V = 3.203954 V 16:44:38 Temperature Measurement, Probe Number = 0, T = 7.635000 C 16:44:40 Temperature Measurement, Probe Number = 1, T = 29.324000 C 16:44:42 Temperature Measurement, Probe Number = 2, T = 29.270000 C 16:44:44 Temperature Measurement, Probe Number = 3, T = 27.893000 C 16:44:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.374350 V 16:44:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374350 (V, A, ohm, ...), Measured Value = 29.088194 (C, atm, Hz, ...) 16:44:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.404832 V 16:44:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.404832 (V, A, ohm, ...), Measured Value = 29.511563 (C, atm, Hz, ...) 16:44:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281818 V 16:44:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281818 (V, A, ohm, ...), Measured Value = 96.136387 (C, atm, Hz, ...) 16:44:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095997 V 16:44:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095997 (V, A, ohm, ...), Measured Value = 7.199805 (C, atm, Hz, ...) 16:45:01 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000892 V 16:45:01 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000892 (V, A, ohm, ...), Measured Value = 0.891945 (C, atm, Hz, ...) 16:45:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 7.63 P3 = Right Coil Outgoing Side, Value = 29.32 P4 = Left Coil Middle, Value = 29.27 P5 = Ambient, Value = 27.89 P6 = Supply Temp(C), Value = 29.09 P7 = Return Temp(C), Value = 29.51 P8 = Supply Pres(psi), Value = 96.14 P9 = Return Pres(psi), Value = 7.20 P10 = Flow Rate(gpm), Value = 0.89 16:45:01 Magnetic Field Measurement Measuring the magnet strength... 16:45:01 Integrated Voltage Measurement... 16:45:03 Magnet Current for MAIN, Imag = 87.4733 A Vtrans = 0.874725 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:45:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866836 Vs 16:45:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016853255 Vs 16:45:25 Magnet Current for MAIN, Imag = 87.4734 A Vtrans = 0.874726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:45:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866979 Vs 16:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852155 Vs 16:45:46 Magnet Current for MAIN, Imag = 87.4737 A Vtrans = 0.874728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:45:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016867088 Vs 16:46:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852718 Vs 16:46:07 Magnet Current for MAIN, Imag = 87.4734 A Vtrans = 0.874726 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:46:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016864967 Vs 16:46:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016851746 Vs 16:46:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016859468 +- 0.000000665 Vs 16:46:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016859468 +- 0.000000665 Vs BL = -0.18732742 +- 0.00000739 Tm 16:46:29 Position moved: 0.000000 m 16:46:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18733 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18733 0.00001 -0.18733 0.00000 16:46:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18733 0.00001 SL = -0.1873274 +- 0.0000074 Tm^2/m^n 16:46:29 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1873274 +- 0.0000074 Tm^2/m^n 16:46:32 Position moved: 0.000000 m 16:46:32 Magnet system MAIN current ramping to 125.0000 A... 16:47:06 Magnet Current for MAIN, Imag = 125.0001 A Vtrans = 1.249993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:47:08 Main (V) Voltage Measurement, V = 4.593569 V 16:47:14 Temperature Measurement, Probe Number = 0, T = 9.985000 C 16:47:16 Temperature Measurement, Probe Number = 1, T = 29.490000 C 16:47:18 Temperature Measurement, Probe Number = 2, T = 29.426000 C 16:47:20 Temperature Measurement, Probe Number = 3, T = 27.943000 C 16:47:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375015 V 16:47:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375015 (V, A, ohm, ...), Measured Value = 29.097433 (C, atm, Hz, ...) 16:47:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.415755 V 16:47:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.415755 (V, A, ohm, ...), Measured Value = 29.663267 (C, atm, Hz, ...) 16:47:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.271426 V 16:47:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.271426 (V, A, ohm, ...), Measured Value = 95.356920 (C, atm, Hz, ...) 16:47:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.095981 V 16:47:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.095981 (V, A, ohm, ...), Measured Value = 7.198545 (C, atm, Hz, ...) 16:47:36 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000881 V 16:47:36 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000881 (V, A, ohm, ...), Measured Value = 0.881344 (C, atm, Hz, ...) 16:47:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = 9.98 P3 = Right Coil Outgoing Side, Value = 29.49 P4 = Left Coil Middle, Value = 29.43 P5 = Ambient, Value = 27.94 P6 = Supply Temp(C), Value = 29.10 P7 = Return Temp(C), Value = 29.66 P8 = Supply Pres(psi), Value = 95.36 P9 = Return Pres(psi), Value = 7.20 P10 = Flow Rate(gpm), Value = 0.88 16:47:36 Magnet system MAIN current ramping to 0.0000 A... 16:49:00 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = -0.000010 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:49:02 Main (V) Voltage Measurement, V = -0.000005 V 16:49:07 Temperature Measurement, Probe Number = 0, T = 11.742000 C 16:49:10 Temperature Measurement, Probe Number = 1, T = 29.669000 C 16:49:12 Temperature Measurement, Probe Number = 2, T = 29.459000 C 16:49:14 Temperature Measurement, Probe Number = 3, T = 27.946000 C 16:49:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375554 V 16:49:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375554 (V, A, ohm, ...), Measured Value = 29.104914 (C, atm, Hz, ...) 16:49:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.435430 V 16:49:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.435430 (V, A, ohm, ...), Measured Value = 29.936531 (C, atm, Hz, ...) 16:49:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276568 V 16:49:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276568 (V, A, ohm, ...), Measured Value = 95.742585 (C, atm, Hz, ...) 16:49:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096226 V 16:49:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096226 (V, A, ohm, ...), Measured Value = 7.216950 (C, atm, Hz, ...) 16:49:30 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 16:49:30 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.891286 (C, atm, Hz, ...) 16:49:30 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = -0.00 P2 = Core, Value = 11.74 P3 = Right Coil Outgoing Side, Value = 29.67 P4 = Left Coil Middle, Value = 29.46 P5 = Ambient, Value = 27.95 P6 = Supply Temp(C), Value = 29.10 P7 = Return Temp(C), Value = 29.94 P8 = Supply Pres(psi), Value = 95.74 P9 = Return Pres(psi), Value = 7.22 P10 = Flow Rate(gpm), Value = 0.89 16:49:30 Magnet system MAIN current ramping to 75.0000 A... 16:50:26 Magnet Current for MAIN, Imag = 75.0258 A Vtrans = 0.750249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:50:28 Main (V) Voltage Measurement, V = 2.744285 V 16:50:33 Temperature Measurement, Probe Number = 0, T = -11.308000 C 16:50:35 Temperature Measurement, Probe Number = 1, T = 29.432000 C 16:50:37 Temperature Measurement, Probe Number = 2, T = 29.247000 C 16:50:39 Temperature Measurement, Probe Number = 3, T = 27.959000 C 16:50:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.375857 V 16:50:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.375857 (V, A, ohm, ...), Measured Value = 29.109131 (C, atm, Hz, ...) 16:50:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.433644 V 16:50:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.433644 (V, A, ohm, ...), Measured Value = 29.911719 (C, atm, Hz, ...) 16:50:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.276316 V 16:50:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.276316 (V, A, ohm, ...), Measured Value = 95.723693 (C, atm, Hz, ...) 16:50:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096393 V 16:50:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096393 (V, A, ohm, ...), Measured Value = 7.229452 (C, atm, Hz, ...) 16:50:56 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000886 V 16:50:56 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000886 (V, A, ohm, ...), Measured Value = 0.886178 (C, atm, Hz, ...) 16:50:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = -11.31 P3 = Right Coil Outgoing Side, Value = 29.43 P4 = Left Coil Middle, Value = 29.25 P5 = Ambient, Value = 27.96 P6 = Supply Temp(C), Value = 29.11 P7 = Return Temp(C), Value = 29.91 P8 = Supply Pres(psi), Value = 95.72 P9 = Return Pres(psi), Value = 7.23 P10 = Flow Rate(gpm), Value = 0.89 16:50:56 Magnetic Field Measurement Measuring the magnet strength... 16:50:56 Integrated Voltage Measurement... 16:50:58 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750255 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475344 Vs 16:51:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460560 Vs 16:51:20 Magnet Current for MAIN, Imag = 75.0263 A Vtrans = 0.750255 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:51:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474539 Vs 16:51:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460857 Vs 16:51:41 Magnet Current for MAIN, Imag = 75.0261 A Vtrans = 0.750252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014475101 Vs 16:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461326 Vs 16:52:02 Magnet Current for MAIN, Imag = 75.0259 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:52:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014473847 Vs 16:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461919 Vs 16:52:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014467937 +- 0.000000185 Vs 16:52:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014467937 +- 0.000000185 Vs BL = -0.16075485 +- 0.00000206 Tm 16:52:24 Position moved: 0.000000 m 16:52:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16075 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16075 0.00000 -0.16075 0.00000 16:52:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16075 0.00000 SL = -0.1607549 +- 0.0000021 Tm^2/m^n 16:52:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607549 +- 0.0000021 Tm^2/m^n 16:52:27 Position moved: 0.000000 m 16:52:30 Position moved: 0.000000 m 16:52:32 Magnet system MAIN current ramping to 87.5000 A... 16:52:53 Magnet Current for MAIN, Imag = 87.4740 A Vtrans = 0.874731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:52:55 Main (V) Voltage Measurement, V = 3.204229 V 16:53:00 Temperature Measurement, Probe Number = 0, T = 8.907000 C 16:53:02 Temperature Measurement, Probe Number = 1, T = 29.356000 C 16:53:04 Temperature Measurement, Probe Number = 2, T = 29.299000 C 16:53:06 Temperature Measurement, Probe Number = 3, T = 27.974000 C 16:53:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376175 V 16:53:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376175 (V, A, ohm, ...), Measured Value = 29.113543 (C, atm, Hz, ...) 16:53:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.410473 V 16:53:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.410473 (V, A, ohm, ...), Measured Value = 29.589907 (C, atm, Hz, ...) 16:53:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.283841 V 16:53:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.283841 (V, A, ohm, ...), Measured Value = 96.288098 (C, atm, Hz, ...) 16:53:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096475 V 16:53:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096475 (V, A, ohm, ...), Measured Value = 7.235648 (C, atm, Hz, ...) 16:53:23 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000891 V 16:53:23 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000891 (V, A, ohm, ...), Measured Value = 0.890973 (C, atm, Hz, ...) 16:53:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 87.47 P1 = Main (V), Value = 3.20 P2 = Core, Value = 8.91 P3 = Right Coil Outgoing Side, Value = 29.36 P4 = Left Coil Middle, Value = 29.30 P5 = Ambient, Value = 27.97 P6 = Supply Temp(C), Value = 29.11 P7 = Return Temp(C), Value = 29.59 P8 = Supply Pres(psi), Value = 96.29 P9 = Return Pres(psi), Value = 7.24 P10 = Flow Rate(gpm), Value = 0.89 16:53:23 Magnetic Field Measurement Measuring the magnet strength... 16:53:23 Integrated Voltage Measurement... 16:53:25 Magnet Current for MAIN, Imag = 87.4737 A Vtrans = 0.874728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:53:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016867113 Vs 16:53:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016852792 Vs 16:53:46 Magnet Current for MAIN, Imag = 87.4745 A Vtrans = 0.874736 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:53:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866113 Vs 16:54:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016851211 Vs 16:54:07 Magnet Current for MAIN, Imag = 87.4740 A Vtrans = 0.874731 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:54:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866064 Vs 16:54:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016851893 Vs 16:54:28 Magnet Current for MAIN, Imag = 87.4737 A Vtrans = 0.874728 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:54:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016866370 Vs 16:54:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.016853336 Vs 16:54:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.016859361 +- 0.000000554 Vs 16:54:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.016859361 +- 0.000000554 Vs BL = -0.18732624 +- 0.00000615 Tm 16:54:51 Position moved: 0.000000 m 16:54:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.18733 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.18733 0.00001 -0.18733 0.00000 16:54:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.18733 0.00001 SL = -0.1873262 +- 0.0000062 Tm^2/m^n 16:54:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1873262 +- 0.0000062 Tm^2/m^n 16:54:53 Position moved: 0.000000 m 16:54:53 Magnet system MAIN current ramping to 125.0000 A... 16:55:28 Magnet Current for MAIN, Imag = 124.9983 A Vtrans = 1.249974 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:55:30 Main (V) Voltage Measurement, V = 4.593894 V 16:55:35 Temperature Measurement, Probe Number = 0, T = 11.579000 C 16:55:37 Temperature Measurement, Probe Number = 1, T = 29.523000 C 16:55:39 Temperature Measurement, Probe Number = 2, T = 29.453000 C 16:55:41 Temperature Measurement, Probe Number = 3, T = 27.965000 C 16:55:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.376771 V 16:55:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376771 (V, A, ohm, ...), Measured Value = 29.121814 (C, atm, Hz, ...) 16:55:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.419993 V 16:55:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.419993 (V, A, ohm, ...), Measured Value = 29.722129 (C, atm, Hz, ...) 16:55:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.281515 V 16:55:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.281515 (V, A, ohm, ...), Measured Value = 96.113617 (C, atm, Hz, ...) 16:55:50 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096243 V 16:55:50 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096243 (V, A, ohm, ...), Measured Value = 7.218210 (C, atm, Hz, ...) 16:55:58 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000900 V 16:55:58 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000900 (V, A, ohm, ...), Measured Value = 0.900332 (C, atm, Hz, ...) 16:55:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.00 P1 = Main (V), Value = 4.59 P2 = Core, Value = 11.58 P3 = Right Coil Outgoing Side, Value = 29.52 P4 = Left Coil Middle, Value = 29.45 P5 = Ambient, Value = 27.96 P6 = Supply Temp(C), Value = 29.12 P7 = Return Temp(C), Value = 29.72 P8 = Supply Pres(psi), Value = 96.11 P9 = Return Pres(psi), Value = 7.22 P10 = Flow Rate(gpm), Value = 0.90 16:55:58 Magnet system MAIN current ramping to 0.0000 A... 16:57:22 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000008 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:57:24 Main (V) Voltage Measurement, V = 0.000000 V 16:57:29 Temperature Measurement, Probe Number = 0, T = 4.613000 C 16:57:31 Temperature Measurement, Probe Number = 1, T = 29.710000 C 16:57:33 Temperature Measurement, Probe Number = 2, T = 29.486000 C 16:57:35 Temperature Measurement, Probe Number = 3, T = 27.985000 C 16:57:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377250 V 16:57:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377250 (V, A, ohm, ...), Measured Value = 29.128469 (C, atm, Hz, ...) 16:57:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.439602 V 16:57:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.439602 (V, A, ohm, ...), Measured Value = 29.994478 (C, atm, Hz, ...) 16:57:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.275540 V 16:57:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.275540 (V, A, ohm, ...), Measured Value = 95.665470 (C, atm, Hz, ...) 16:57:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.096758 V 16:57:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.096758 (V, A, ohm, ...), Measured Value = 7.256865 (C, atm, Hz, ...) 16:57:52 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000899 V 16:57:52 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000899 (V, A, ohm, ...), Measured Value = 0.898534 (C, atm, Hz, ...) 16:57:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = 0.00 P2 = Core, Value = 4.61 P3 = Right Coil Outgoing Side, Value = 29.71 P4 = Left Coil Middle, Value = 29.49 P5 = Ambient, Value = 27.98 P6 = Supply Temp(C), Value = 29.13 P7 = Return Temp(C), Value = 29.99 P8 = Supply Pres(psi), Value = 95.67 P9 = Return Pres(psi), Value = 7.26 P10 = Flow Rate(gpm), Value = 0.90 16:57:52 Magnet system MAIN current ramping to 75.0000 A... 16:58:47 Magnet Current for MAIN, Imag = 75.0262 A Vtrans = 0.750253 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:58:49 Main (V) Voltage Measurement, V = 2.744409 V 16:58:55 Temperature Measurement, Probe Number = 0, T = 6.238000 C 16:58:57 Temperature Measurement, Probe Number = 1, T = 29.471000 C 16:58:59 Temperature Measurement, Probe Number = 2, T = 29.274000 C 16:59:01 Temperature Measurement, Probe Number = 3, T = 28.008000 C 16:59:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.377601 V 16:59:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.377601 (V, A, ohm, ...), Measured Value = 29.133349 (C, atm, Hz, ...) 16:59:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.437460 V 16:59:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.437460 (V, A, ohm, ...), Measured Value = 29.964715 (C, atm, Hz, ...) 16:59:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.274163 V 16:59:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.274163 (V, A, ohm, ...), Measured Value = 95.562203 (C, atm, Hz, ...) 16:59:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.097138 V 16:59:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.097138 (V, A, ohm, ...), Measured Value = 7.285350 (C, atm, Hz, ...) 16:59:17 Sensor Voltage Measurement, Sensor Number = 4, V = 0.000896 V 16:59:17 Sensor Measurement, Sensor Number = 4, Sensor Type = WATER_KEYENCE_FLOW Raw Sensor Output = 0.000896 (V, A, ohm, ...), Measured Value = 0.895854 (C, atm, Hz, ...) 16:59:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.03 P1 = Main (V), Value = 2.74 P2 = Core, Value = 6.24 P3 = Right Coil Outgoing Side, Value = 29.47 P4 = Left Coil Middle, Value = 29.27 P5 = Ambient, Value = 28.01 P6 = Supply Temp(C), Value = 29.13 P7 = Return Temp(C), Value = 29.96 P8 = Supply Pres(psi), Value = 95.56 P9 = Return Pres(psi), Value = 7.29 P10 = Flow Rate(gpm), Value = 0.90 16:59:17 Magnetic Field Measurement Measuring the magnet strength... 16:59:17 Integrated Voltage Measurement... 16:59:19 Magnet Current for MAIN, Imag = 75.0259 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:59:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474725 Vs 16:59:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461250 Vs 16:59:41 Magnet Current for MAIN, Imag = 75.0262 A Vtrans = 0.750253 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 16:59:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474783 Vs 17:00:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014460621 Vs 17:00:02 Magnet Current for MAIN, Imag = 75.0259 A Vtrans = 0.750251 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 17:00:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014474490 Vs 17:00:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014459806 Vs 17:00:23 Magnet Current for MAIN, Imag = 75.0258 A Vtrans = 0.750249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.000875 A 17:00:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014473457 Vs 17:00:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = 0.014461407 Vs 17:00:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = -0.014467567 +- 0.000000312 Vs 17:00:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = -0.014467567 +- 0.000000312 Vs BL = -0.16075075 +- 0.00000346 Tm 17:00:45 Position moved: 0.000000 m 17:00:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.16075 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.16075 0.00000 -0.16075 0.00000 17:00:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.16075 0.00000 SL = -0.1607507 +- 0.0000035 Tm^2/m^n 17:00:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1607507 +- 0.0000035 Tm^2/m^n 17:00:48 Position moved: 0.000000 m 17:00:51 Position moved: 0.000000 m 17:00:54 Magnet system MAIN current ramping to 0.0000 A...