SLAC Magnetic Measurements Date: 05-28-2019 Time: 17:01:45 Project: LCLS-II Magnet Type: Dipole Magnet Name: 4509 Serial Number: Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integral field strength vs current from 0 to 200 to 0 amps in 10 amp steps. Standardization for MAIN: 15 cycles from 0.0 A to 200.0 A to 0.0 A Test Currents for MAIN (A): 0.00 10.00 20.00 30.00 40.00 50.00 60.00 70.00 80.00 90.00 100.00 110.00 120.00 130.00 140.00 150.00 160.00 170.00 180.00 190.00 200.00 190.00 180.00 170.00 160.00 150.00 140.00 130.00 120.00 110.00 100.00 90.00 80.00 70.00 60.00 50.00 40.00 30.00 20.00 10.00 0.00 17:02:12 Position moved: 0.000000 m 17:02:27 Magnet Current for MAIN, Imag = -0.0025 A Vtrans = -0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:28 Magnet Current for MAIN, Imag = -0.0025 A Vtrans = -0.000025 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:28 Magnet Current for MAIN, Imag = -0.0024 A Vtrans = -0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:29 Magnet Current for MAIN, Imag = -0.0024 A Vtrans = -0.000024 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:02:29 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0024 +- 0.0000 A 17:02:49 Initial Zero Current Measurement for MAIN, Imag_zero = -0.0024469 A 17:02:49 Ambient Measurement Device(s) Being Used, type = None 17:02:49 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 17:02:50 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:02:50 XMAG Device(s) Being Used, type = None 17:02:50 Ambient Measurement Device(s) Being Used, type = HP34970 17:02:50 Magnet system MAIN current ramping to 200.0000 A... 17:04:43 Magnet Current for MAIN, Imag = 200.0146 A Vtrans = 2.000121 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:04:44 MAIN (V) Voltage Measurement, V = 14.306094 V 17:04:44 Temperature Measurement, Probe Number = 0, T = 28.604000 C 17:04:45 Temperature Measurement, Probe Number = 1, T = 26.835000 C 17:04:46 Temperature Measurement, Probe Number = 2, T = 24.046000 C 17:04:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336838 V 17:04:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336838 (V, A, ohm, ...), Measured Value = 28.567193 (C, atm, Hz, ...) 17:04:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.451688 V 17:04:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.451688 (V, A, ohm, ...), Measured Value = 30.162340 (C, atm, Hz, ...) 17:04:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670797 V 17:04:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670797 (V, A, ohm, ...), Measured Value = 125.309745 (C, atm, Hz, ...) 17:04:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107505 V 17:04:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107505 (V, A, ohm, ...), Measured Value = 8.062905 (C, atm, Hz, ...) 17:04:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.01 P1 = MAIN (V), Value = 14.31 P2 = Coil, Value = 28.60 P3 = Magnet Core, Value = 26.84 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 30.16 P7 = Supply Pres(psi), Value = 125.31 P8 = Return Pres(psi), Value = 8.06 17:05:49 Magnet Current for MAIN, Imag = 200.0142 A Vtrans = 2.000117 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:05:50 MAIN (V) Voltage Measurement, V = 14.340572 V 17:05:50 Temperature Measurement, Probe Number = 0, T = 28.860000 C 17:05:51 Temperature Measurement, Probe Number = 1, T = 26.863000 C 17:05:52 Temperature Measurement, Probe Number = 2, T = 24.074000 C 17:05:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336819 V 17:05:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336819 (V, A, ohm, ...), Measured Value = 28.566929 (C, atm, Hz, ...) 17:05:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.442502 V 17:05:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.442502 (V, A, ohm, ...), Measured Value = 30.034757 (C, atm, Hz, ...) 17:05:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661482 V 17:05:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661482 (V, A, ohm, ...), Measured Value = 124.611158 (C, atm, Hz, ...) 17:05:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107518 V 17:05:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107518 (V, A, ohm, ...), Measured Value = 8.063865 (C, atm, Hz, ...) 17:05:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.01 P1 = MAIN (V), Value = 14.34 P2 = Coil, Value = 28.86 P3 = Magnet Core, Value = 26.86 P4 = Ambient Temp (C), Value = 24.07 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 30.03 P7 = Supply Pres(psi), Value = 124.61 P8 = Return Pres(psi), Value = 8.06 17:06:55 Magnet Current for MAIN, Imag = 200.0148 A Vtrans = 2.000124 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:06:56 MAIN (V) Voltage Measurement, V = 14.352389 V 17:06:56 Temperature Measurement, Probe Number = 0, T = 29.074000 C 17:06:57 Temperature Measurement, Probe Number = 1, T = 26.902000 C 17:06:57 Temperature Measurement, Probe Number = 2, T = 24.052000 C 17:06:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336764 V 17:06:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336764 (V, A, ohm, ...), Measured Value = 28.566169 (C, atm, Hz, ...) 17:06:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.449347 V 17:06:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.449347 (V, A, ohm, ...), Measured Value = 30.129822 (C, atm, Hz, ...) 17:06:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669698 V 17:06:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669698 (V, A, ohm, ...), Measured Value = 125.227380 (C, atm, Hz, ...) 17:07:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107607 V 17:07:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107607 (V, A, ohm, ...), Measured Value = 8.070533 (C, atm, Hz, ...) 17:07:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.01 P1 = MAIN (V), Value = 14.35 P2 = Coil, Value = 29.07 P3 = Magnet Core, Value = 26.90 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 30.13 P7 = Supply Pres(psi), Value = 125.23 P8 = Return Pres(psi), Value = 8.07 17:08:01 Magnet Current for MAIN, Imag = 200.0151 A Vtrans = 2.000126 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:08:01 MAIN (V) Voltage Measurement, V = 14.356765 V 17:08:02 Temperature Measurement, Probe Number = 0, T = 29.229000 C 17:08:03 Temperature Measurement, Probe Number = 1, T = 26.941000 C 17:08:03 Temperature Measurement, Probe Number = 2, T = 24.046000 C 17:08:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336609 V 17:08:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336609 (V, A, ohm, ...), Measured Value = 28.564015 (C, atm, Hz, ...) 17:08:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.465539 V 17:08:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.465539 (V, A, ohm, ...), Measured Value = 30.354714 (C, atm, Hz, ...) 17:08:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663530 V 17:08:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663530 (V, A, ohm, ...), Measured Value = 124.764735 (C, atm, Hz, ...) 17:08:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107285 V 17:08:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107285 (V, A, ohm, ...), Measured Value = 8.046412 (C, atm, Hz, ...) 17:08:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.23 P3 = Magnet Core, Value = 26.94 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.35 P7 = Supply Pres(psi), Value = 124.76 P8 = Return Pres(psi), Value = 8.05 17:09:07 Magnet Current for MAIN, Imag = 200.0156 A Vtrans = 2.000131 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:09:07 MAIN (V) Voltage Measurement, V = 14.358565 V 17:09:08 Temperature Measurement, Probe Number = 0, T = 29.301000 C 17:09:09 Temperature Measurement, Probe Number = 1, T = 26.975000 C 17:09:09 Temperature Measurement, Probe Number = 2, T = 24.048000 C 17:09:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336482 V 17:09:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336482 (V, A, ohm, ...), Measured Value = 28.562250 (C, atm, Hz, ...) 17:09:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.482248 V 17:09:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.482248 (V, A, ohm, ...), Measured Value = 30.586774 (C, atm, Hz, ...) 17:09:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659217 V 17:09:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659217 (V, A, ohm, ...), Measured Value = 124.441282 (C, atm, Hz, ...) 17:09:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107367 V 17:09:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107367 (V, A, ohm, ...), Measured Value = 8.052517 (C, atm, Hz, ...) 17:09:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.30 P3 = Magnet Core, Value = 26.98 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.59 P7 = Supply Pres(psi), Value = 124.44 P8 = Return Pres(psi), Value = 8.05 17:10:13 Magnet Current for MAIN, Imag = 200.0157 A Vtrans = 2.000132 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:10:13 MAIN (V) Voltage Measurement, V = 14.359445 V 17:10:14 Temperature Measurement, Probe Number = 0, T = 29.363000 C 17:10:15 Temperature Measurement, Probe Number = 1, T = 27.020000 C 17:10:15 Temperature Measurement, Probe Number = 2, T = 24.051000 C 17:10:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336477 V 17:10:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336477 (V, A, ohm, ...), Measured Value = 28.562179 (C, atm, Hz, ...) 17:10:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.496762 V 17:10:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.496762 (V, A, ohm, ...), Measured Value = 30.788363 (C, atm, Hz, ...) 17:10:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669175 V 17:10:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669175 (V, A, ohm, ...), Measured Value = 125.188103 (C, atm, Hz, ...) 17:10:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107228 V 17:10:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107228 (V, A, ohm, ...), Measured Value = 8.042130 (C, atm, Hz, ...) 17:10:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.36 P3 = Magnet Core, Value = 27.02 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.79 P7 = Supply Pres(psi), Value = 125.19 P8 = Return Pres(psi), Value = 8.04 17:11:19 Magnet Current for MAIN, Imag = 200.0166 A Vtrans = 2.000141 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:11:19 MAIN (V) Voltage Measurement, V = 14.360006 V 17:11:20 Temperature Measurement, Probe Number = 0, T = 29.391000 C 17:11:20 Temperature Measurement, Probe Number = 1, T = 27.058000 C 17:11:21 Temperature Measurement, Probe Number = 2, T = 24.056000 C 17:11:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336459 V 17:11:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336459 (V, A, ohm, ...), Measured Value = 28.561933 (C, atm, Hz, ...) 17:11:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.510131 V 17:11:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.510131 (V, A, ohm, ...), Measured Value = 30.974044 (C, atm, Hz, ...) 17:11:23 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657274 V 17:11:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657274 (V, A, ohm, ...), Measured Value = 124.295520 (C, atm, Hz, ...) 17:11:24 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107161 V 17:11:24 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107161 (V, A, ohm, ...), Measured Value = 8.037075 (C, atm, Hz, ...) 17:11:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.39 P3 = Magnet Core, Value = 27.06 P4 = Ambient Temp (C), Value = 24.06 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.97 P7 = Supply Pres(psi), Value = 124.30 P8 = Return Pres(psi), Value = 8.04 17:12:24 Magnet Current for MAIN, Imag = 200.0166 A Vtrans = 2.000141 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:12:25 MAIN (V) Voltage Measurement, V = 14.360376 V 17:12:26 Temperature Measurement, Probe Number = 0, T = 29.405000 C 17:12:26 Temperature Measurement, Probe Number = 1, T = 27.077000 C 17:12:27 Temperature Measurement, Probe Number = 2, T = 24.029000 C 17:12:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336483 V 17:12:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336483 (V, A, ohm, ...), Measured Value = 28.562268 (C, atm, Hz, ...) 17:12:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.522378 V 17:12:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.522378 (V, A, ohm, ...), Measured Value = 31.144143 (C, atm, Hz, ...) 17:12:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667516 V 17:12:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667516 (V, A, ohm, ...), Measured Value = 125.063693 (C, atm, Hz, ...) 17:12:30 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107566 V 17:12:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107566 (V, A, ohm, ...), Measured Value = 8.067487 (C, atm, Hz, ...) 17:12:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.41 P3 = Magnet Core, Value = 27.08 P4 = Ambient Temp (C), Value = 24.03 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.14 P7 = Supply Pres(psi), Value = 125.06 P8 = Return Pres(psi), Value = 8.07 17:13:30 Magnet Current for MAIN, Imag = 200.0168 A Vtrans = 2.000144 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:13:31 MAIN (V) Voltage Measurement, V = 14.360861 V 17:13:32 Temperature Measurement, Probe Number = 0, T = 29.419000 C 17:13:32 Temperature Measurement, Probe Number = 1, T = 27.110000 C 17:13:33 Temperature Measurement, Probe Number = 2, T = 24.030000 C 17:13:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336546 V 17:13:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336546 (V, A, ohm, ...), Measured Value = 28.563133 (C, atm, Hz, ...) 17:13:34 Sensor Voltage Measurement, Sensor Number = 1, V = 2.533213 V 17:13:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.533213 (V, A, ohm, ...), Measured Value = 31.294624 (C, atm, Hz, ...) 17:13:35 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657211 V 17:13:35 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657211 (V, A, ohm, ...), Measured Value = 124.290848 (C, atm, Hz, ...) 17:13:35 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107472 V 17:13:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107472 (V, A, ohm, ...), Measured Value = 8.060430 (C, atm, Hz, ...) 17:13:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.42 P3 = Magnet Core, Value = 27.11 P4 = Ambient Temp (C), Value = 24.03 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.29 P7 = Supply Pres(psi), Value = 124.29 P8 = Return Pres(psi), Value = 8.06 17:14:36 Magnet Current for MAIN, Imag = 200.0176 A Vtrans = 2.000152 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:14:37 MAIN (V) Voltage Measurement, V = 14.361129 V 17:14:37 Temperature Measurement, Probe Number = 0, T = 29.431000 C 17:14:38 Temperature Measurement, Probe Number = 1, T = 27.160000 C 17:14:39 Temperature Measurement, Probe Number = 2, T = 24.039000 C 17:14:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336624 V 17:14:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336624 (V, A, ohm, ...), Measured Value = 28.564228 (C, atm, Hz, ...) 17:14:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.542432 V 17:14:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.542432 (V, A, ohm, ...), Measured Value = 31.422667 (C, atm, Hz, ...) 17:14:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670259 V 17:14:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670259 (V, A, ohm, ...), Measured Value = 125.269417 (C, atm, Hz, ...) 17:14:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107399 V 17:14:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107399 (V, A, ohm, ...), Measured Value = 8.054903 (C, atm, Hz, ...) 17:14:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.43 P3 = Magnet Core, Value = 27.16 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.42 P7 = Supply Pres(psi), Value = 125.27 P8 = Return Pres(psi), Value = 8.05 17:15:42 Magnet Current for MAIN, Imag = 200.0180 A Vtrans = 2.000155 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:15:43 MAIN (V) Voltage Measurement, V = 14.361499 V 17:15:43 Temperature Measurement, Probe Number = 0, T = 29.450000 C 17:15:44 Temperature Measurement, Probe Number = 1, T = 27.199000 C 17:15:45 Temperature Measurement, Probe Number = 2, T = 24.041000 C 17:15:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336579 V 17:15:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336579 (V, A, ohm, ...), Measured Value = 28.563592 (C, atm, Hz, ...) 17:15:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.550453 V 17:15:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.550453 (V, A, ohm, ...), Measured Value = 31.534063 (C, atm, Hz, ...) 17:15:47 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667737 V 17:15:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667737 (V, A, ohm, ...), Measured Value = 125.080283 (C, atm, Hz, ...) 17:15:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107264 V 17:15:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107264 (V, A, ohm, ...), Measured Value = 8.044792 (C, atm, Hz, ...) 17:15:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.45 P3 = Magnet Core, Value = 27.20 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.53 P7 = Supply Pres(psi), Value = 125.08 P8 = Return Pres(psi), Value = 8.04 17:16:48 Magnet Current for MAIN, Imag = 200.0176 A Vtrans = 2.000152 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:16:49 MAIN (V) Voltage Measurement, V = 14.361780 V 17:16:49 Temperature Measurement, Probe Number = 0, T = 29.478000 C 17:16:50 Temperature Measurement, Probe Number = 1, T = 27.242000 C 17:16:51 Temperature Measurement, Probe Number = 2, T = 23.964000 C 17:16:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336734 V 17:16:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336734 (V, A, ohm, ...), Measured Value = 28.565746 (C, atm, Hz, ...) 17:16:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.557365 V 17:16:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.557365 (V, A, ohm, ...), Measured Value = 31.630064 (C, atm, Hz, ...) 17:16:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.684049 V 17:16:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.684049 (V, A, ohm, ...), Measured Value = 126.303660 (C, atm, Hz, ...) 17:16:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107711 V 17:16:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107711 (V, A, ohm, ...), Measured Value = 8.078355 (C, atm, Hz, ...) 17:16:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.48 P3 = Magnet Core, Value = 27.24 P4 = Ambient Temp (C), Value = 23.96 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 31.63 P7 = Supply Pres(psi), Value = 126.30 P8 = Return Pres(psi), Value = 8.08 17:17:54 Magnet Current for MAIN, Imag = 200.0185 A Vtrans = 2.000160 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:17:55 MAIN (V) Voltage Measurement, V = 14.362112 V 17:17:55 Temperature Measurement, Probe Number = 0, T = 29.489000 C 17:17:56 Temperature Measurement, Probe Number = 1, T = 27.280000 C 17:17:56 Temperature Measurement, Probe Number = 2, T = 23.939000 C 17:17:57 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336674 V 17:17:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336674 (V, A, ohm, ...), Measured Value = 28.564917 (C, atm, Hz, ...) 17:17:58 Sensor Voltage Measurement, Sensor Number = 1, V = 2.563189 V 17:17:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.563189 (V, A, ohm, ...), Measured Value = 31.710954 (C, atm, Hz, ...) 17:17:59 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667185 V 17:17:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667185 (V, A, ohm, ...), Measured Value = 125.038912 (C, atm, Hz, ...) 17:17:59 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107835 V 17:17:59 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107835 (V, A, ohm, ...), Measured Value = 8.087602 (C, atm, Hz, ...) 17:17:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.49 P3 = Magnet Core, Value = 27.28 P4 = Ambient Temp (C), Value = 23.94 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.71 P7 = Supply Pres(psi), Value = 125.04 P8 = Return Pres(psi), Value = 8.09 17:19:00 Magnet Current for MAIN, Imag = 200.0189 A Vtrans = 2.000164 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:19:01 MAIN (V) Voltage Measurement, V = 14.362393 V 17:19:01 Temperature Measurement, Probe Number = 0, T = 29.490000 C 17:19:02 Temperature Measurement, Probe Number = 1, T = 27.316000 C 17:19:02 Temperature Measurement, Probe Number = 2, T = 23.987000 C 17:19:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336674 V 17:19:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336674 (V, A, ohm, ...), Measured Value = 28.564917 (C, atm, Hz, ...) 17:19:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.568249 V 17:19:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.568249 (V, A, ohm, ...), Measured Value = 31.781233 (C, atm, Hz, ...) 17:19:04 Sensor Voltage Measurement, Sensor Number = 2, V = 2.676207 V 17:19:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.676207 (V, A, ohm, ...), Measured Value = 125.715562 (C, atm, Hz, ...) 17:19:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107816 V 17:19:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107816 (V, A, ohm, ...), Measured Value = 8.086170 (C, atm, Hz, ...) 17:19:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.49 P3 = Magnet Core, Value = 27.32 P4 = Ambient Temp (C), Value = 23.99 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 31.78 P7 = Supply Pres(psi), Value = 125.72 P8 = Return Pres(psi), Value = 8.09 17:20:06 Magnet Current for MAIN, Imag = 200.0187 A Vtrans = 2.000163 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:20:06 MAIN (V) Voltage Measurement, V = 14.362610 V 17:20:07 Temperature Measurement, Probe Number = 0, T = 29.487000 C 17:20:08 Temperature Measurement, Probe Number = 1, T = 27.352000 C 17:20:08 Temperature Measurement, Probe Number = 2, T = 23.977000 C 17:20:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336729 V 17:20:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336729 (V, A, ohm, ...), Measured Value = 28.565675 (C, atm, Hz, ...) 17:20:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.572626 V 17:20:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.572626 (V, A, ohm, ...), Measured Value = 31.842033 (C, atm, Hz, ...) 17:20:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663005 V 17:20:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663005 (V, A, ohm, ...), Measured Value = 124.725367 (C, atm, Hz, ...) 17:20:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107668 V 17:20:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107668 (V, A, ohm, ...), Measured Value = 8.075107 (C, atm, Hz, ...) 17:20:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.49 P3 = Magnet Core, Value = 27.35 P4 = Ambient Temp (C), Value = 23.98 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 31.84 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 8.08 17:21:12 Magnet Current for MAIN, Imag = 200.0189 A Vtrans = 2.000164 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:21:12 MAIN (V) Voltage Measurement, V = 14.362903 V 17:21:13 Temperature Measurement, Probe Number = 0, T = 29.478000 C 17:21:14 Temperature Measurement, Probe Number = 1, T = 27.384000 C 17:21:14 Temperature Measurement, Probe Number = 2, T = 23.950000 C 17:21:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336703 V 17:21:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336703 (V, A, ohm, ...), Measured Value = 28.565322 (C, atm, Hz, ...) 17:21:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.576208 V 17:21:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.576208 (V, A, ohm, ...), Measured Value = 31.891782 (C, atm, Hz, ...) 17:21:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655530 V 17:21:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655530 (V, A, ohm, ...), Measured Value = 124.164728 (C, atm, Hz, ...) 17:21:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107585 V 17:21:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107585 (V, A, ohm, ...), Measured Value = 8.068912 (C, atm, Hz, ...) 17:21:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.48 P3 = Magnet Core, Value = 27.38 P4 = Ambient Temp (C), Value = 23.95 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 31.89 P7 = Supply Pres(psi), Value = 124.16 P8 = Return Pres(psi), Value = 8.07 17:22:18 Magnet Current for MAIN, Imag = 200.0195 A Vtrans = 2.000171 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:22:18 MAIN (V) Voltage Measurement, V = 14.363158 V 17:22:19 Temperature Measurement, Probe Number = 0, T = 29.478000 C 17:22:19 Temperature Measurement, Probe Number = 1, T = 27.417000 C 17:22:20 Temperature Measurement, Probe Number = 2, T = 23.956000 C 17:22:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336772 V 17:22:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336772 (V, A, ohm, ...), Measured Value = 28.566275 (C, atm, Hz, ...) 17:22:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.579438 V 17:22:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.579438 (V, A, ohm, ...), Measured Value = 31.936640 (C, atm, Hz, ...) 17:22:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661386 V 17:22:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661386 (V, A, ohm, ...), Measured Value = 124.603913 (C, atm, Hz, ...) 17:22:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107822 V 17:22:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107822 (V, A, ohm, ...), Measured Value = 8.086643 (C, atm, Hz, ...) 17:22:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.48 P3 = Magnet Core, Value = 27.42 P4 = Ambient Temp (C), Value = 23.96 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 31.94 P7 = Supply Pres(psi), Value = 124.60 P8 = Return Pres(psi), Value = 8.09 17:23:23 Magnet Current for MAIN, Imag = 200.0199 A Vtrans = 2.000174 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:23:24 MAIN (V) Voltage Measurement, V = 14.363324 V 17:23:25 Temperature Measurement, Probe Number = 0, T = 29.497000 C 17:23:25 Temperature Measurement, Probe Number = 1, T = 27.435000 C 17:23:26 Temperature Measurement, Probe Number = 2, T = 23.986000 C 17:23:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336739 V 17:23:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336739 (V, A, ohm, ...), Measured Value = 28.565817 (C, atm, Hz, ...) 17:23:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.582384 V 17:23:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.582384 (V, A, ohm, ...), Measured Value = 31.977561 (C, atm, Hz, ...) 17:23:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660770 V 17:23:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660770 (V, A, ohm, ...), Measured Value = 124.557772 (C, atm, Hz, ...) 17:23:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107705 V 17:23:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107705 (V, A, ohm, ...), Measured Value = 8.077875 (C, atm, Hz, ...) 17:23:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.50 P3 = Magnet Core, Value = 27.43 P4 = Ambient Temp (C), Value = 23.99 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 31.98 P7 = Supply Pres(psi), Value = 124.56 P8 = Return Pres(psi), Value = 8.08 17:24:29 Magnet Current for MAIN, Imag = 200.0198 A Vtrans = 2.000173 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:24:30 MAIN (V) Voltage Measurement, V = 14.363503 V 17:24:31 Temperature Measurement, Probe Number = 0, T = 29.501000 C 17:24:31 Temperature Measurement, Probe Number = 1, T = 27.473000 C 17:24:32 Temperature Measurement, Probe Number = 2, T = 24.007000 C 17:24:33 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336663 V 17:24:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336663 (V, A, ohm, ...), Measured Value = 28.564757 (C, atm, Hz, ...) 17:24:33 Sensor Voltage Measurement, Sensor Number = 1, V = 2.584763 V 17:24:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.584763 (V, A, ohm, ...), Measured Value = 32.010592 (C, atm, Hz, ...) 17:24:34 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663226 V 17:24:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663226 (V, A, ohm, ...), Measured Value = 124.741958 (C, atm, Hz, ...) 17:24:34 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107877 V 17:24:35 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107877 (V, A, ohm, ...), Measured Value = 8.090745 (C, atm, Hz, ...) 17:24:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.50 P3 = Magnet Core, Value = 27.47 P4 = Ambient Temp (C), Value = 24.01 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.01 P7 = Supply Pres(psi), Value = 124.74 P8 = Return Pres(psi), Value = 8.09 17:25:35 Magnet Current for MAIN, Imag = 200.0207 A Vtrans = 2.000182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:25:36 MAIN (V) Voltage Measurement, V = 14.363694 V 17:25:37 Temperature Measurement, Probe Number = 0, T = 29.522000 C 17:25:37 Temperature Measurement, Probe Number = 1, T = 27.497000 C 17:25:38 Temperature Measurement, Probe Number = 2, T = 24.034000 C 17:25:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336682 V 17:25:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336682 (V, A, ohm, ...), Measured Value = 28.565022 (C, atm, Hz, ...) 17:25:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.586851 V 17:25:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.586851 (V, A, ohm, ...), Measured Value = 32.039597 (C, atm, Hz, ...) 17:25:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668477 V 17:25:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668477 (V, A, ohm, ...), Measured Value = 125.135768 (C, atm, Hz, ...) 17:25:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107794 V 17:25:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107794 (V, A, ohm, ...), Measured Value = 8.084550 (C, atm, Hz, ...) 17:25:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.52 P3 = Magnet Core, Value = 27.50 P4 = Ambient Temp (C), Value = 24.03 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 32.04 P7 = Supply Pres(psi), Value = 125.14 P8 = Return Pres(psi), Value = 8.08 17:26:41 Magnet Current for MAIN, Imag = 200.0208 A Vtrans = 2.000183 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:26:42 MAIN (V) Voltage Measurement, V = 14.363860 V 17:26:42 Temperature Measurement, Probe Number = 0, T = 29.530000 C 17:26:43 Temperature Measurement, Probe Number = 1, T = 27.534000 C 17:26:44 Temperature Measurement, Probe Number = 2, T = 24.014000 C 17:26:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336687 V 17:26:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336687 (V, A, ohm, ...), Measured Value = 28.565093 (C, atm, Hz, ...) 17:26:45 Sensor Voltage Measurement, Sensor Number = 1, V = 2.588675 V 17:26:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.588675 (V, A, ohm, ...), Measured Value = 32.064931 (C, atm, Hz, ...) 17:26:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662740 V 17:26:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662740 (V, A, ohm, ...), Measured Value = 124.705537 (C, atm, Hz, ...) 17:26:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107821 V 17:26:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107821 (V, A, ohm, ...), Measured Value = 8.086552 (C, atm, Hz, ...) 17:26:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.53 P3 = Magnet Core, Value = 27.53 P4 = Ambient Temp (C), Value = 24.01 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 32.06 P7 = Supply Pres(psi), Value = 124.71 P8 = Return Pres(psi), Value = 8.09 17:27:47 Magnet Current for MAIN, Imag = 200.0214 A Vtrans = 2.000190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:27:48 MAIN (V) Voltage Measurement, V = 14.364102 V 17:27:48 Temperature Measurement, Probe Number = 0, T = 29.534000 C 17:27:49 Temperature Measurement, Probe Number = 1, T = 27.557000 C 17:27:50 Temperature Measurement, Probe Number = 2, T = 24.021000 C 17:27:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336806 V 17:27:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336806 (V, A, ohm, ...), Measured Value = 28.566753 (C, atm, Hz, ...) 17:27:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.590438 V 17:27:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.590438 (V, A, ohm, ...), Measured Value = 32.089415 (C, atm, Hz, ...) 17:27:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660676 V 17:27:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660676 (V, A, ohm, ...), Measured Value = 124.550723 (C, atm, Hz, ...) 17:27:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107807 V 17:27:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107807 (V, A, ohm, ...), Measured Value = 8.085503 (C, atm, Hz, ...) 17:27:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.53 P3 = Magnet Core, Value = 27.56 P4 = Ambient Temp (C), Value = 24.02 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 32.09 P7 = Supply Pres(psi), Value = 124.55 P8 = Return Pres(psi), Value = 8.09 17:28:53 Magnet Current for MAIN, Imag = 200.0213 A Vtrans = 2.000188 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:28:54 MAIN (V) Voltage Measurement, V = 14.364243 V 17:28:54 Temperature Measurement, Probe Number = 0, T = 29.516000 C 17:28:55 Temperature Measurement, Probe Number = 1, T = 27.589000 C 17:28:55 Temperature Measurement, Probe Number = 2, T = 24.020000 C 17:28:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336505 V 17:28:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336505 (V, A, ohm, ...), Measured Value = 28.562568 (C, atm, Hz, ...) 17:28:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.591947 V 17:28:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.591947 (V, A, ohm, ...), Measured Value = 32.110371 (C, atm, Hz, ...) 17:28:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669879 V 17:28:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669879 (V, A, ohm, ...), Measured Value = 125.240918 (C, atm, Hz, ...) 17:28:58 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107903 V 17:28:58 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107903 (V, A, ohm, ...), Measured Value = 8.092748 (C, atm, Hz, ...) 17:28:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.52 P3 = Magnet Core, Value = 27.59 P4 = Ambient Temp (C), Value = 24.02 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.11 P7 = Supply Pres(psi), Value = 125.24 P8 = Return Pres(psi), Value = 8.09 17:29:59 Magnet Current for MAIN, Imag = 200.0214 A Vtrans = 2.000190 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:29:59 MAIN (V) Voltage Measurement, V = 14.364421 V 17:30:00 Temperature Measurement, Probe Number = 0, T = 29.533000 C 17:30:01 Temperature Measurement, Probe Number = 1, T = 27.611000 C 17:30:01 Temperature Measurement, Probe Number = 2, T = 24.044000 C 17:30:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336670 V 17:30:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336670 (V, A, ohm, ...), Measured Value = 28.564863 (C, atm, Hz, ...) 17:30:03 Sensor Voltage Measurement, Sensor Number = 1, V = 2.593326 V 17:30:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.593326 (V, A, ohm, ...), Measured Value = 32.129525 (C, atm, Hz, ...) 17:30:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661060 V 17:30:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661060 (V, A, ohm, ...), Measured Value = 124.579507 (C, atm, Hz, ...) 17:30:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107962 V 17:30:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107962 (V, A, ohm, ...), Measured Value = 8.097135 (C, atm, Hz, ...) 17:30:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.53 P3 = Magnet Core, Value = 27.61 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.13 P7 = Supply Pres(psi), Value = 124.58 P8 = Return Pres(psi), Value = 8.10 17:31:05 Magnet Current for MAIN, Imag = 200.0217 A Vtrans = 2.000192 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:31:05 MAIN (V) Voltage Measurement, V = 14.364613 V 17:31:06 Temperature Measurement, Probe Number = 0, T = 29.541000 C 17:31:07 Temperature Measurement, Probe Number = 1, T = 27.639000 C 17:31:07 Temperature Measurement, Probe Number = 2, T = 24.022000 C 17:31:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336601 V 17:31:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336601 (V, A, ohm, ...), Measured Value = 28.563910 (C, atm, Hz, ...) 17:31:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.594632 V 17:31:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.594632 (V, A, ohm, ...), Measured Value = 32.147674 (C, atm, Hz, ...) 17:31:09 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664592 V 17:31:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664592 (V, A, ohm, ...), Measured Value = 124.844437 (C, atm, Hz, ...) 17:31:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107667 V 17:31:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107667 (V, A, ohm, ...), Measured Value = 8.075017 (C, atm, Hz, ...) 17:31:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.54 P3 = Magnet Core, Value = 27.64 P4 = Ambient Temp (C), Value = 24.02 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.15 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 8.08 17:32:11 Magnet Current for MAIN, Imag = 200.0218 A Vtrans = 2.000193 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:32:11 MAIN (V) Voltage Measurement, V = 14.364753 V 17:32:12 Temperature Measurement, Probe Number = 0, T = 29.542000 C 17:32:12 Temperature Measurement, Probe Number = 1, T = 27.674000 C 17:32:13 Temperature Measurement, Probe Number = 2, T = 24.040000 C 17:32:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336534 V 17:32:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336534 (V, A, ohm, ...), Measured Value = 28.562974 (C, atm, Hz, ...) 17:32:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.595835 V 17:32:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.595835 (V, A, ohm, ...), Measured Value = 32.164374 (C, atm, Hz, ...) 17:32:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657971 V 17:32:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657971 (V, A, ohm, ...), Measured Value = 124.347855 (C, atm, Hz, ...) 17:32:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107744 V 17:32:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107744 (V, A, ohm, ...), Measured Value = 8.080830 (C, atm, Hz, ...) 17:32:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.54 P3 = Magnet Core, Value = 27.67 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.16 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 8.08 17:33:17 Magnet Current for MAIN, Imag = 200.0218 A Vtrans = 2.000193 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:33:17 MAIN (V) Voltage Measurement, V = 14.364804 V 17:33:18 Temperature Measurement, Probe Number = 0, T = 29.547000 C 17:33:18 Temperature Measurement, Probe Number = 1, T = 27.699000 C 17:33:19 Temperature Measurement, Probe Number = 2, T = 24.042000 C 17:33:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336406 V 17:33:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336406 (V, A, ohm, ...), Measured Value = 28.561192 (C, atm, Hz, ...) 17:33:20 Sensor Voltage Measurement, Sensor Number = 1, V = 2.596889 V 17:33:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.596889 (V, A, ohm, ...), Measured Value = 32.179008 (C, atm, Hz, ...) 17:33:21 Sensor Voltage Measurement, Sensor Number = 2, V = 2.673644 V 17:33:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.673644 (V, A, ohm, ...), Measured Value = 125.523285 (C, atm, Hz, ...) 17:33:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107658 V 17:33:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107658 (V, A, ohm, ...), Measured Value = 8.074350 (C, atm, Hz, ...) 17:33:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.55 P3 = Magnet Core, Value = 27.70 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.18 P7 = Supply Pres(psi), Value = 125.52 P8 = Return Pres(psi), Value = 8.07 17:34:22 Magnet Current for MAIN, Imag = 200.0226 A Vtrans = 2.000201 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:34:23 MAIN (V) Voltage Measurement, V = 14.364906 V 17:34:24 Temperature Measurement, Probe Number = 0, T = 29.550000 C 17:34:24 Temperature Measurement, Probe Number = 1, T = 27.732000 C 17:34:25 Temperature Measurement, Probe Number = 2, T = 24.025000 C 17:34:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336333 V 17:34:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336333 (V, A, ohm, ...), Measured Value = 28.560185 (C, atm, Hz, ...) 17:34:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.598003 V 17:34:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.598003 (V, A, ohm, ...), Measured Value = 32.194492 (C, atm, Hz, ...) 17:34:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666756 V 17:34:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666756 (V, A, ohm, ...), Measured Value = 125.006685 (C, atm, Hz, ...) 17:34:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107788 V 17:34:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107788 (V, A, ohm, ...), Measured Value = 8.084070 (C, atm, Hz, ...) 17:34:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.36 P2 = Coil, Value = 29.55 P3 = Magnet Core, Value = 27.73 P4 = Ambient Temp (C), Value = 24.02 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.19 P7 = Supply Pres(psi), Value = 125.01 P8 = Return Pres(psi), Value = 8.08 17:35:28 Magnet Current for MAIN, Imag = 200.0222 A Vtrans = 2.000197 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 17:35:29 MAIN (V) Voltage Measurement, V = 14.365085 V 17:35:30 Temperature Measurement, Probe Number = 0, T = 29.558000 C 17:35:30 Temperature Measurement, Probe Number = 1, T = 27.751000 C 17:35:31 Temperature Measurement, Probe Number = 2, T = 24.037000 C 17:35:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336261 V 17:35:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336261 (V, A, ohm, ...), Measured Value = 28.559179 (C, atm, Hz, ...) 17:35:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.598907 V 17:35:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.598907 (V, A, ohm, ...), Measured Value = 32.207043 (C, atm, Hz, ...) 17:35:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667872 V 17:35:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667872 (V, A, ohm, ...), Measured Value = 125.090385 (C, atm, Hz, ...) 17:35:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107696 V 17:35:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107696 (V, A, ohm, ...), Measured Value = 8.077208 (C, atm, Hz, ...) 17:35:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.02 P1 = MAIN (V), Value = 14.37 P2 = Coil, Value = 29.56 P3 = Magnet Core, Value = 27.75 P4 = Ambient Temp (C), Value = 24.04 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 32.21 P7 = Supply Pres(psi), Value = 125.09 P8 = Return Pres(psi), Value = 8.08 17:35:34 Magnet system MAIN current ramping to 0.0000 A... 17:37:36 Magnet system MAIN current ramping to 200.0000 A... 17:39:38 Magnet system MAIN current ramping to 0.0000 A... 17:41:40 Magnet system MAIN current ramping to 200.0000 A... 17:43:43 Magnet system MAIN current ramping to 0.0000 A... 17:45:45 Magnet system MAIN current ramping to 200.0000 A... 17:47:47 Magnet system MAIN current ramping to 0.0000 A... 17:49:50 Magnet system MAIN current ramping to 200.0000 A... 17:51:52 Magnet system MAIN current ramping to 0.0000 A... 17:53:54 Magnet system MAIN current ramping to 200.0000 A... 17:55:57 Magnet system MAIN current ramping to 0.0000 A... 17:57:59 Magnet system MAIN current ramping to 200.0000 A... 18:00:01 Magnet system MAIN current ramping to 0.0000 A... 18:02:03 Magnet system MAIN current ramping to 200.0000 A... 18:04:06 Magnet system MAIN current ramping to 0.0000 A... 18:06:08 Magnet system MAIN current ramping to 200.0000 A... 18:08:10 Magnet system MAIN current ramping to 0.0000 A... 18:10:13 Magnet system MAIN current ramping to 200.0000 A... 18:12:15 Magnet system MAIN current ramping to 0.0000 A... 18:14:17 Magnet system MAIN current ramping to 200.0000 A... 18:16:20 Magnet system MAIN current ramping to 0.0000 A... 18:18:22 Magnet system MAIN current ramping to 200.0000 A... 18:20:24 Magnet system MAIN current ramping to 0.0000 A... 18:22:27 Magnet system MAIN current ramping to 200.0000 A... 18:24:29 Magnet system MAIN current ramping to 0.0000 A... 18:26:31 Magnet system MAIN current ramping to 200.0000 A... 18:28:33 Magnet system MAIN current ramping to 0.0000 A... 18:30:36 Magnet system MAIN current ramping to 200.0000 A... 18:32:38 Magnet system MAIN current ramping to 0.0000 A... 18:34:40 Magnet system MAIN current ramping to 200.0000 A... 18:36:43 Magnet system MAIN current ramping to 0.0000 A... 18:38:48 Position moved: 0.000000 m 18:38:50 Magnet system MAIN current ramping to 0.0000 A... 18:39:02 Magnet Current for MAIN, Imag = 0.0071 A Vtrans = 0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:39:02 MAIN (V) Voltage Measurement, V = 0.000500 V 18:39:03 Temperature Measurement, Probe Number = 0, T = 28.735000 C 18:39:04 Temperature Measurement, Probe Number = 1, T = 28.071000 C 18:39:04 Temperature Measurement, Probe Number = 2, T = 24.107000 C 18:39:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336396 V 18:39:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336396 (V, A, ohm, ...), Measured Value = 28.561050 (C, atm, Hz, ...) 18:39:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.449429 V 18:39:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.449429 (V, A, ohm, ...), Measured Value = 30.130953 (C, atm, Hz, ...) 18:39:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.672874 V 18:39:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672874 (V, A, ohm, ...), Measured Value = 125.465513 (C, atm, Hz, ...) 18:39:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105611 V 18:39:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105611 (V, A, ohm, ...), Measured Value = 7.920862 (C, atm, Hz, ...) 18:39:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Coil, Value = 28.73 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 24.11 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.13 P7 = Supply Pres(psi), Value = 125.47 P8 = Return Pres(psi), Value = 7.92 18:39:07 Magnetic Field Measurement Measuring the magnet strength... 18:39:07 Integrated Voltage Measurement... 18:39:08 Magnet Current for MAIN, Imag = 0.0071 A Vtrans = 0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000497859 Vs 18:39:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000490491 Vs 18:39:25 Magnet Current for MAIN, Imag = 0.0073 A Vtrans = 0.000049 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:39:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000497773 Vs 18:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000492392 Vs 18:39:41 Magnet Current for MAIN, Imag = 0.0071 A Vtrans = 0.000046 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:39:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000495032 Vs 18:39:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000492838 Vs 18:39:58 Magnet Current for MAIN, Imag = 0.0069 A Vtrans = 0.000045 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000495378 Vs 18:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000493429 Vs 18:40:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000494399 +- 0.000000428 Vs 18:40:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.000494399 +- 0.000000428 Vs BL = 0.00549332 +- 0.00000475 Tm 18:40:17 Position moved: 0.000000 m 18:40:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00549 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00549 0.00000 0.00549 0.00000 18:40:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00549 0.00000 SL = 0.0054933 +- 0.0000048 Tm^2/m^n 18:40:17 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0054933 +- 0.0000048 Tm^2/m^n 18:40:20 Position moved: 0.000000 m 18:40:20 Magnet system MAIN current ramping to 10.0000 A... 18:40:37 Magnet Current for MAIN, Imag = 9.9902 A Vtrans = 0.099877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:40:38 MAIN (V) Voltage Measurement, V = 0.709156 V 18:40:38 Temperature Measurement, Probe Number = 0, T = 28.480000 C 18:40:39 Temperature Measurement, Probe Number = 1, T = 28.069000 C 18:40:40 Temperature Measurement, Probe Number = 2, T = 24.123000 C 18:40:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336655 V 18:40:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336655 (V, A, ohm, ...), Measured Value = 28.564651 (C, atm, Hz, ...) 18:40:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.442757 V 18:40:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.442757 (V, A, ohm, ...), Measured Value = 30.038287 (C, atm, Hz, ...) 18:40:41 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657832 V 18:40:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657832 (V, A, ohm, ...), Measured Value = 124.337370 (C, atm, Hz, ...) 18:40:42 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105776 V 18:40:42 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105776 (V, A, ohm, ...), Measured Value = 7.933163 (C, atm, Hz, ...) 18:40:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 9.99 P1 = MAIN (V), Value = 0.71 P2 = Coil, Value = 28.48 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 24.12 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 30.04 P7 = Supply Pres(psi), Value = 124.34 P8 = Return Pres(psi), Value = 7.93 18:40:42 Magnetic Field Measurement Measuring the magnet strength... 18:40:42 Integrated Voltage Measurement... 18:40:43 Magnet Current for MAIN, Imag = 9.9903 A Vtrans = 0.099879 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:40:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005003041 Vs 18:41:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005009731 Vs 18:41:00 Magnet Current for MAIN, Imag = 9.9902 A Vtrans = 0.099878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:41:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005001193 Vs 18:41:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005008334 Vs 18:41:17 Magnet Current for MAIN, Imag = 9.9901 A Vtrans = 0.099877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:41:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005001400 Vs 18:41:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005010025 Vs 18:41:33 Magnet Current for MAIN, Imag = 9.9901 A Vtrans = 0.099876 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:41:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005001086 Vs 18:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005010788 Vs 18:41:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005005700 +- 0.000000593 Vs 18:41:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.005005700 +- 0.000000593 Vs BL = 0.05561889 +- 0.00000658 Tm 18:41:53 Position moved: 0.000000 m 18:41:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.05562 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.05562 0.00001 0.05562 0.00000 18:41:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.05562 0.00001 SL = 0.0556189 +- 0.0000066 Tm^2/m^n 18:41:53 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0556189 +- 0.0000066 Tm^2/m^n 18:41:56 Position moved: 0.000000 m 18:41:56 Magnet system MAIN current ramping to 20.0000 A... 18:42:13 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:42:13 MAIN (V) Voltage Measurement, V = 1.417602 V 18:42:14 Temperature Measurement, Probe Number = 0, T = 28.350000 C 18:42:14 Temperature Measurement, Probe Number = 1, T = 28.049000 C 18:42:15 Temperature Measurement, Probe Number = 2, T = 24.113000 C 18:42:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336629 V 18:42:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336629 (V, A, ohm, ...), Measured Value = 28.564299 (C, atm, Hz, ...) 18:42:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.423490 V 18:42:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.423490 (V, A, ohm, ...), Measured Value = 29.770692 (C, atm, Hz, ...) 18:42:17 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663021 V 18:42:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663021 (V, A, ohm, ...), Measured Value = 124.726605 (C, atm, Hz, ...) 18:42:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105589 V 18:42:18 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105589 (V, A, ohm, ...), Measured Value = 7.919152 (C, atm, Hz, ...) 18:42:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 1.42 P2 = Coil, Value = 28.35 P3 = Magnet Core, Value = 28.05 P4 = Ambient Temp (C), Value = 24.11 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.77 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 7.92 18:42:18 Magnetic Field Measurement Measuring the magnet strength... 18:42:18 Integrated Voltage Measurement... 18:42:18 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:42:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009563615 Vs 18:42:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009570099 Vs 18:42:36 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009564235 Vs 18:42:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009569236 Vs 18:42:52 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:43:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009564045 Vs 18:43:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009568568 Vs 18:43:09 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009566231 Vs 18:43:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009565363 Vs 18:43:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009566424 +- 0.000000416 Vs 18:43:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.009566424 +- 0.000000416 Vs BL = 0.10629360 +- 0.00000462 Tm 18:43:29 Position moved: 0.000000 m 18:43:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.10629 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.10629 0.00000 0.10629 0.00000 18:43:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.10629 0.00000 SL = 0.1062936 +- 0.0000046 Tm^2/m^n 18:43:29 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1062936 +- 0.0000046 Tm^2/m^n 18:43:32 Position moved: 0.000000 m 18:43:32 Magnet system MAIN current ramping to 30.0000 A... 18:43:48 Magnet Current for MAIN, Imag = 29.9680 A Vtrans = 0.299655 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:43:49 MAIN (V) Voltage Measurement, V = 2.126401 V 18:43:50 Temperature Measurement, Probe Number = 0, T = 28.300000 C 18:43:50 Temperature Measurement, Probe Number = 1, T = 28.041000 C 18:43:51 Temperature Measurement, Probe Number = 2, T = 24.090000 C 18:43:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336403 V 18:43:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336403 (V, A, ohm, ...), Measured Value = 28.561156 (C, atm, Hz, ...) 18:43:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402556 V 18:43:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402556 (V, A, ohm, ...), Measured Value = 29.479947 (C, atm, Hz, ...) 18:43:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659803 V 18:43:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659803 (V, A, ohm, ...), Measured Value = 124.485232 (C, atm, Hz, ...) 18:43:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105824 V 18:43:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105824 (V, A, ohm, ...), Measured Value = 7.936785 (C, atm, Hz, ...) 18:43:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 29.97 P1 = MAIN (V), Value = 2.13 P2 = Coil, Value = 28.30 P3 = Magnet Core, Value = 28.04 P4 = Ambient Temp (C), Value = 24.09 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.48 P7 = Supply Pres(psi), Value = 124.49 P8 = Return Pres(psi), Value = 7.94 18:43:54 Magnetic Field Measurement Measuring the magnet strength... 18:43:54 Integrated Voltage Measurement... 18:43:54 Magnet Current for MAIN, Imag = 29.9679 A Vtrans = 0.299655 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014143086 Vs 18:44:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014151259 Vs 18:44:12 Magnet Current for MAIN, Imag = 29.9679 A Vtrans = 0.299655 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:44:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014145640 Vs 18:44:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014145142 Vs 18:44:29 Magnet Current for MAIN, Imag = 29.9676 A Vtrans = 0.299652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:44:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014148432 Vs 18:44:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014144291 Vs 18:44:45 Magnet Current for MAIN, Imag = 29.9677 A Vtrans = 0.299653 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:44:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014145454 Vs 18:45:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014145675 Vs 18:45:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014146123 +- 0.000000708 Vs 18:45:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.014146123 +- 0.000000708 Vs BL = 0.15717914 +- 0.00000787 Tm 18:45:05 Position moved: 0.000000 m 18:45:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.15718 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.15718 0.00001 0.15718 0.00000 18:45:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.15718 0.00001 SL = 0.1571791 +- 0.0000079 Tm^2/m^n 18:45:05 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1571791 +- 0.0000079 Tm^2/m^n 18:45:08 Position moved: 0.000000 m 18:45:08 Magnet system MAIN current ramping to 40.0000 A... 18:45:24 Magnet Current for MAIN, Imag = 39.9658 A Vtrans = 0.399633 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:45:25 MAIN (V) Voltage Measurement, V = 2.836100 V 18:45:26 Temperature Measurement, Probe Number = 0, T = 28.272000 C 18:45:26 Temperature Measurement, Probe Number = 1, T = 28.014000 C 18:45:27 Temperature Measurement, Probe Number = 2, T = 24.060000 C 18:45:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336352 V 18:45:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336352 (V, A, ohm, ...), Measured Value = 28.560450 (C, atm, Hz, ...) 18:45:28 Sensor Voltage Measurement, Sensor Number = 1, V = 2.385206 V 18:45:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.385206 (V, A, ohm, ...), Measured Value = 29.238974 (C, atm, Hz, ...) 18:45:29 Sensor Voltage Measurement, Sensor Number = 2, V = 2.672368 V 18:45:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672368 (V, A, ohm, ...), Measured Value = 125.427570 (C, atm, Hz, ...) 18:45:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105509 V 18:45:30 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105509 (V, A, ohm, ...), Measured Value = 7.913145 (C, atm, Hz, ...) 18:45:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.97 P1 = MAIN (V), Value = 2.84 P2 = Coil, Value = 28.27 P3 = Magnet Core, Value = 28.01 P4 = Ambient Temp (C), Value = 24.06 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.24 P7 = Supply Pres(psi), Value = 125.43 P8 = Return Pres(psi), Value = 7.91 18:45:30 Magnetic Field Measurement Measuring the magnet strength... 18:45:30 Integrated Voltage Measurement... 18:45:30 Magnet Current for MAIN, Imag = 39.9662 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:45:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.018752928 Vs 18:45:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.018750670 Vs 18:45:48 Magnet Current for MAIN, Imag = 39.9659 A Vtrans = 0.399635 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:45:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.018755362 Vs 18:46:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.018745039 Vs 18:46:04 Magnet Current for MAIN, Imag = 39.9661 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:46:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.018751185 Vs 18:46:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.018745886 Vs 18:46:21 Magnet Current for MAIN, Imag = 39.9661 A Vtrans = 0.399636 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:46:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.018746229 Vs 18:46:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.018747982 Vs 18:46:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.018749410 +- 0.000001761 Vs 18:46:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.018749410 +- 0.000001761 Vs BL = 0.20832678 +- 0.00001957 Tm 18:46:41 Position moved: 0.000000 m 18:46:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.20833 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.20833 0.00002 0.20833 0.00000 18:46:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.20833 0.00002 SL = 0.2083268 +- 0.0000196 Tm^2/m^n 18:46:41 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2083268 +- 0.0000196 Tm^2/m^n 18:46:44 Position moved: 0.000000 m 18:46:44 Magnet system MAIN current ramping to 50.0000 A... 18:47:00 Magnet Current for MAIN, Imag = 49.9527 A Vtrans = 0.499502 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:47:01 MAIN (V) Voltage Measurement, V = 3.545447 V 18:47:01 Temperature Measurement, Probe Number = 0, T = 28.265000 C 18:47:02 Temperature Measurement, Probe Number = 1, T = 27.984000 C 18:47:03 Temperature Measurement, Probe Number = 2, T = 24.002000 C 18:47:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336241 V 18:47:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336241 (V, A, ohm, ...), Measured Value = 28.558896 (C, atm, Hz, ...) 18:47:04 Sensor Voltage Measurement, Sensor Number = 1, V = 2.372148 V 18:47:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.372148 (V, A, ohm, ...), Measured Value = 29.057617 (C, atm, Hz, ...) 18:47:05 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662335 V 18:47:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662335 (V, A, ohm, ...), Measured Value = 124.675125 (C, atm, Hz, ...) 18:47:05 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105296 V 18:47:05 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105296 (V, A, ohm, ...), Measured Value = 7.897223 (C, atm, Hz, ...) 18:47:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 49.95 P1 = MAIN (V), Value = 3.55 P2 = Coil, Value = 28.27 P3 = Magnet Core, Value = 27.98 P4 = Ambient Temp (C), Value = 24.00 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.06 P7 = Supply Pres(psi), Value = 124.68 P8 = Return Pres(psi), Value = 7.90 18:47:05 Magnetic Field Measurement Measuring the magnet strength... 18:47:05 Integrated Voltage Measurement... 18:47:06 Magnet Current for MAIN, Imag = 49.9527 A Vtrans = 0.499502 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:47:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023351157 Vs 18:47:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023364094 Vs 18:47:24 Magnet Current for MAIN, Imag = 49.9527 A Vtrans = 0.499502 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:47:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023349146 Vs 18:47:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023364371 Vs 18:47:40 Magnet Current for MAIN, Imag = 49.9526 A Vtrans = 0.499501 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:47:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023347393 Vs 18:47:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023372222 Vs 18:47:57 Magnet Current for MAIN, Imag = 49.9529 A Vtrans = 0.499504 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023347661 Vs 18:48:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023370937 Vs 18:48:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023358372 +- 0.000001233 Vs 18:48:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.023358372 +- 0.000001233 Vs BL = 0.25953747 +- 0.00001370 Tm 18:48:16 Position moved: 0.000000 m 18:48:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.25954 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.25954 0.00001 0.25954 0.00000 18:48:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.25954 0.00001 SL = 0.2595375 +- 0.0000137 Tm^2/m^n 18:48:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2595375 +- 0.0000137 Tm^2/m^n 18:48:19 Position moved: 0.000000 m 18:48:19 Magnet system MAIN current ramping to 60.0000 A... 18:48:36 Magnet Current for MAIN, Imag = 59.9438 A Vtrans = 0.599413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:48:36 MAIN (V) Voltage Measurement, V = 4.255650 V 18:48:37 Temperature Measurement, Probe Number = 0, T = 28.257000 C 18:48:38 Temperature Measurement, Probe Number = 1, T = 27.980000 C 18:48:38 Temperature Measurement, Probe Number = 2, T = 24.027000 C 18:48:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336280 V 18:48:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336280 (V, A, ohm, ...), Measured Value = 28.559443 (C, atm, Hz, ...) 18:48:40 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363307 V 18:48:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363307 (V, A, ohm, ...), Measured Value = 28.934817 (C, atm, Hz, ...) 18:48:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659016 V 18:48:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659016 (V, A, ohm, ...), Measured Value = 124.426223 (C, atm, Hz, ...) 18:48:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105262 V 18:48:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105262 (V, A, ohm, ...), Measured Value = 7.894650 (C, atm, Hz, ...) 18:48:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = MAIN (V), Value = 4.26 P2 = Coil, Value = 28.26 P3 = Magnet Core, Value = 27.98 P4 = Ambient Temp (C), Value = 24.03 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 28.93 P7 = Supply Pres(psi), Value = 124.43 P8 = Return Pres(psi), Value = 7.89 18:48:41 Magnetic Field Measurement Measuring the magnet strength... 18:48:41 Integrated Voltage Measurement... 18:48:42 Magnet Current for MAIN, Imag = 59.9438 A Vtrans = 0.599413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.027964301 Vs 18:48:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.027987463 Vs 18:48:59 Magnet Current for MAIN, Imag = 59.9438 A Vtrans = 0.599414 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:49:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.027968822 Vs 18:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.027990721 Vs 18:49:16 Magnet Current for MAIN, Imag = 59.9442 A Vtrans = 0.599417 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.027970198 Vs 18:49:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.027996430 Vs 18:49:32 Magnet Current for MAIN, Imag = 59.9441 A Vtrans = 0.599416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:49:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.027969430 Vs 18:49:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.027983302 Vs 18:49:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.027978834 +- 0.000002990 Vs 18:49:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.027978834 +- 0.000002990 Vs BL = 0.31087593 +- 0.00003322 Tm 18:49:52 Position moved: 0.000000 m 18:49:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31088 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31088 0.00003 0.31088 0.00000 18:49:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31088 0.00003 SL = 0.3108759 +- 0.0000332 Tm^2/m^n 18:49:52 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3108759 +- 0.0000332 Tm^2/m^n 18:49:55 Position moved: 0.000000 m 18:49:55 Magnet system MAIN current ramping to 70.0000 A... 18:50:11 Magnet Current for MAIN, Imag = 69.9364 A Vtrans = 0.699340 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:50:12 MAIN (V) Voltage Measurement, V = 4.966624 V 18:50:12 Temperature Measurement, Probe Number = 0, T = 28.312000 C 18:50:13 Temperature Measurement, Probe Number = 1, T = 27.970000 C 18:50:14 Temperature Measurement, Probe Number = 2, T = 24.049000 C 18:50:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336235 V 18:50:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336235 (V, A, ohm, ...), Measured Value = 28.558825 (C, atm, Hz, ...) 18:50:15 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358005 V 18:50:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358005 (V, A, ohm, ...), Measured Value = 28.861182 (C, atm, Hz, ...) 18:50:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661935 V 18:50:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661935 (V, A, ohm, ...), Measured Value = 124.645095 (C, atm, Hz, ...) 18:50:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105235 V 18:50:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105235 (V, A, ohm, ...), Measured Value = 7.892647 (C, atm, Hz, ...) 18:50:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 69.94 P1 = MAIN (V), Value = 4.97 P2 = Coil, Value = 28.31 P3 = Magnet Core, Value = 27.97 P4 = Ambient Temp (C), Value = 24.05 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 28.86 P7 = Supply Pres(psi), Value = 124.65 P8 = Return Pres(psi), Value = 7.89 18:50:16 Magnetic Field Measurement Measuring the magnet strength... 18:50:16 Integrated Voltage Measurement... 18:50:17 Magnet Current for MAIN, Imag = 69.9366 A Vtrans = 0.699341 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:50:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.032597627 Vs 18:50:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.032616984 Vs 18:50:35 Magnet Current for MAIN, Imag = 69.9364 A Vtrans = 0.699340 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:50:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.032585941 Vs 18:50:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.032629897 Vs 18:50:51 Magnet Current for MAIN, Imag = 69.9368 A Vtrans = 0.699344 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:50:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.032589403 Vs 18:51:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.032622399 Vs 18:51:07 Magnet Current for MAIN, Imag = 69.9367 A Vtrans = 0.699342 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:51:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.032589568 Vs 18:51:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.032624542 Vs 18:51:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.032607045 +- 0.000000731 Vs 18:51:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.032607045 +- 0.000000731 Vs BL = 0.36230050 +- 0.00000813 Tm 18:51:27 Position moved: 0.000000 m 18:51:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36230 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.36230 0.00001 0.36230 0.00000 18:51:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36230 0.00001 SL = 0.3623005 +- 0.0000081 Tm^2/m^n 18:51:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3623005 +- 0.0000081 Tm^2/m^n 18:51:30 Position moved: 0.000000 m 18:51:30 Magnet system MAIN current ramping to 80.0000 A... 18:51:47 Magnet Current for MAIN, Imag = 79.9438 A Vtrans = 0.799413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:51:47 MAIN (V) Voltage Measurement, V = 5.679575 V 18:51:48 Temperature Measurement, Probe Number = 0, T = 28.358000 C 18:51:49 Temperature Measurement, Probe Number = 1, T = 27.968000 C 18:51:49 Temperature Measurement, Probe Number = 2, T = 24.026000 C 18:51:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336788 V 18:51:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336788 (V, A, ohm, ...), Measured Value = 28.566506 (C, atm, Hz, ...) 18:51:51 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355589 V 18:51:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355589 (V, A, ohm, ...), Measured Value = 28.827622 (C, atm, Hz, ...) 18:51:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659973 V 18:51:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659973 (V, A, ohm, ...), Measured Value = 124.498005 (C, atm, Hz, ...) 18:51:52 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105380 V 18:51:52 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105380 (V, A, ohm, ...), Measured Value = 7.903515 (C, atm, Hz, ...) 18:51:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 79.94 P1 = MAIN (V), Value = 5.68 P2 = Coil, Value = 28.36 P3 = Magnet Core, Value = 27.97 P4 = Ambient Temp (C), Value = 24.03 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 28.83 P7 = Supply Pres(psi), Value = 124.50 P8 = Return Pres(psi), Value = 7.90 18:51:52 Magnetic Field Measurement Measuring the magnet strength... 18:51:52 Integrated Voltage Measurement... 18:51:53 Magnet Current for MAIN, Imag = 79.9440 A Vtrans = 0.799415 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:52:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037228722 Vs 18:52:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037270839 Vs 18:52:10 Magnet Current for MAIN, Imag = 79.9442 A Vtrans = 0.799418 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:52:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037241676 Vs 18:52:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037271089 Vs 18:52:27 Magnet Current for MAIN, Imag = 79.9440 A Vtrans = 0.799415 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:52:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037236684 Vs 18:52:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037272768 Vs 18:52:43 Magnet Current for MAIN, Imag = 79.9440 A Vtrans = 0.799416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:52:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037226949 Vs 18:52:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037273192 Vs 18:52:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037252740 +- 0.000002876 Vs 18:52:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.037252740 +- 0.000002876 Vs BL = 0.41391933 +- 0.00003196 Tm 18:53:03 Position moved: 0.000000 m 18:53:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.41392 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.41392 0.00003 0.41392 0.00000 18:53:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.41392 0.00003 SL = 0.4139193 +- 0.0000320 Tm^2/m^n 18:53:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4139193 +- 0.0000320 Tm^2/m^n 18:53:06 Position moved: 0.000000 m 18:53:06 Magnet system MAIN current ramping to 90.0000 A... 18:53:23 Magnet Current for MAIN, Imag = 90.0095 A Vtrans = 0.900070 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:53:23 MAIN (V) Voltage Measurement, V = 6.397824 V 18:53:24 Temperature Measurement, Probe Number = 0, T = 28.406000 C 18:53:25 Temperature Measurement, Probe Number = 1, T = 27.951000 C 18:53:25 Temperature Measurement, Probe Number = 2, T = 23.998000 C 18:53:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337679 V 18:53:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337679 (V, A, ohm, ...), Measured Value = 28.578881 (C, atm, Hz, ...) 18:53:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.355699 V 18:53:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.355699 (V, A, ohm, ...), Measured Value = 28.829158 (C, atm, Hz, ...) 18:53:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666922 V 18:53:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666922 (V, A, ohm, ...), Measured Value = 125.019172 (C, atm, Hz, ...) 18:53:28 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105022 V 18:53:28 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105022 (V, A, ohm, ...), Measured Value = 7.876635 (C, atm, Hz, ...) 18:53:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 90.01 P1 = MAIN (V), Value = 6.40 P2 = Coil, Value = 28.41 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 24.00 P5 = Supply Temp(C), Value = 28.58 P6 = Return Temp(C), Value = 28.83 P7 = Supply Pres(psi), Value = 125.02 P8 = Return Pres(psi), Value = 7.88 18:53:28 Magnetic Field Measurement Measuring the magnet strength... 18:53:28 Integrated Voltage Measurement... 18:53:29 Magnet Current for MAIN, Imag = 90.0096 A Vtrans = 0.900072 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:53:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.041902390 Vs 18:53:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.041947065 Vs 18:53:46 Magnet Current for MAIN, Imag = 90.0097 A Vtrans = 0.900073 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:53:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.041911668 Vs 18:54:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.041941723 Vs 18:54:03 Magnet Current for MAIN, Imag = 90.0095 A Vtrans = 0.900070 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:54:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.041913533 Vs 18:54:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.041948586 Vs 18:54:19 Magnet Current for MAIN, Imag = 90.0092 A Vtrans = 0.900067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:54:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.041911653 Vs 18:54:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.041944572 Vs 18:54:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.041927649 +- 0.000002307 Vs 18:54:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.041927649 +- 0.000002307 Vs BL = 0.46586276 +- 0.00002563 Tm 18:54:39 Position moved: 0.000000 m 18:54:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.46586 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.46586 0.00003 0.46586 0.00000 18:54:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.46586 0.00003 SL = 0.4658628 +- 0.0000256 Tm^2/m^n 18:54:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4658628 +- 0.0000256 Tm^2/m^n 18:54:42 Position moved: 0.000000 m 18:54:42 Magnet system MAIN current ramping to 100.0000 A... 18:54:58 Magnet Current for MAIN, Imag = 99.9995 A Vtrans = 0.999970 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:54:59 MAIN (V) Voltage Measurement, V = 7.111887 V 18:55:00 Temperature Measurement, Probe Number = 0, T = 28.473000 C 18:55:00 Temperature Measurement, Probe Number = 1, T = 27.948000 C 18:55:01 Temperature Measurement, Probe Number = 2, T = 23.974000 C 18:55:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338508 V 18:55:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338508 (V, A, ohm, ...), Measured Value = 28.590390 (C, atm, Hz, ...) 18:55:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.357901 V 18:55:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.357901 (V, A, ohm, ...), Measured Value = 28.859735 (C, atm, Hz, ...) 18:55:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658423 V 18:55:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658423 (V, A, ohm, ...), Measured Value = 124.381703 (C, atm, Hz, ...) 18:55:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105148 V 18:55:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105148 (V, A, ohm, ...), Measured Value = 7.886070 (C, atm, Hz, ...) 18:55:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.00 P1 = MAIN (V), Value = 7.11 P2 = Coil, Value = 28.47 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.97 P5 = Supply Temp(C), Value = 28.59 P6 = Return Temp(C), Value = 28.86 P7 = Supply Pres(psi), Value = 124.38 P8 = Return Pres(psi), Value = 7.89 18:55:04 Magnetic Field Measurement Measuring the magnet strength... 18:55:04 Integrated Voltage Measurement... 18:55:04 Magnet Current for MAIN, Imag = 99.9997 A Vtrans = 0.999973 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:55:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.046547383 Vs 18:55:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.046565797 Vs 18:55:22 Magnet Current for MAIN, Imag = 99.9997 A Vtrans = 0.999973 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:55:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.046545013 Vs 18:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.046563019 Vs 18:55:39 Magnet Current for MAIN, Imag = 99.9997 A Vtrans = 0.999973 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.046543197 Vs 18:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.046574492 Vs 18:55:55 Magnet Current for MAIN, Imag = 99.9997 A Vtrans = 0.999973 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:56:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.046560939 Vs 18:56:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.046575836 Vs 18:56:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.046559460 +- 0.000005430 Vs 18:56:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.046559460 +- 0.000005430 Vs BL = 0.51732733 +- 0.00006034 Tm 18:56:15 Position moved: 0.000000 m 18:56:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.51733 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.51733 0.00006 0.51733 0.00000 18:56:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.51733 0.00006 SL = 0.5173273 +- 0.0000603 Tm^2/m^n 18:56:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5173273 +- 0.0000603 Tm^2/m^n 18:56:18 Position moved: 0.000000 m 18:56:18 Magnet system MAIN current ramping to 110.0000 A... 18:56:34 Magnet Current for MAIN, Imag = 109.9875 A Vtrans = 1.099850 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:56:35 MAIN (V) Voltage Measurement, V = 7.826919 V 18:56:36 Temperature Measurement, Probe Number = 0, T = 28.531000 C 18:56:36 Temperature Measurement, Probe Number = 1, T = 27.941000 C 18:56:37 Temperature Measurement, Probe Number = 2, T = 23.964000 C 18:56:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338611 V 18:56:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338611 (V, A, ohm, ...), Measured Value = 28.591821 (C, atm, Hz, ...) 18:56:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.362357 V 18:56:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.362357 (V, A, ohm, ...), Measured Value = 28.921629 (C, atm, Hz, ...) 18:56:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658045 V 18:56:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658045 (V, A, ohm, ...), Measured Value = 124.353390 (C, atm, Hz, ...) 18:56:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105300 V 18:56:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105300 (V, A, ohm, ...), Measured Value = 7.897508 (C, atm, Hz, ...) 18:56:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 109.99 P1 = MAIN (V), Value = 7.83 P2 = Coil, Value = 28.53 P3 = Magnet Core, Value = 27.94 P4 = Ambient Temp (C), Value = 23.96 P5 = Supply Temp(C), Value = 28.59 P6 = Return Temp(C), Value = 28.92 P7 = Supply Pres(psi), Value = 124.35 P8 = Return Pres(psi), Value = 7.90 18:56:40 Magnetic Field Measurement Measuring the magnet strength... 18:56:40 Integrated Voltage Measurement... 18:56:40 Magnet Current for MAIN, Imag = 109.9876 A Vtrans = 1.099852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051196670 Vs 18:56:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051205142 Vs 18:56:58 Magnet Current for MAIN, Imag = 109.9877 A Vtrans = 1.099853 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:57:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051186214 Vs 18:57:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051215277 Vs 18:57:14 Magnet Current for MAIN, Imag = 109.9876 A Vtrans = 1.099851 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:57:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051183887 Vs 18:57:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051203499 Vs 18:57:31 Magnet Current for MAIN, Imag = 109.9878 A Vtrans = 1.099853 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:57:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051174720 Vs 18:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051205552 Vs 18:57:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051196370 +- 0.000004630 Vs 18:57:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.051196370 +- 0.000004630 Vs BL = 0.56884856 +- 0.00005145 Tm 18:57:51 Position moved: 0.000000 m 18:57:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.56885 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.56885 0.00005 0.56885 0.00000 18:57:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.56885 0.00005 SL = 0.5688486 +- 0.0000514 Tm^2/m^n 18:57:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5688486 +- 0.0000514 Tm^2/m^n 18:57:54 Position moved: 0.000000 m 18:57:54 Magnet system MAIN current ramping to 120.0000 A... 18:58:10 Magnet Current for MAIN, Imag = 119.9901 A Vtrans = 1.199877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:58:11 MAIN (V) Voltage Measurement, V = 8.544102 V 18:58:11 Temperature Measurement, Probe Number = 0, T = 28.590000 C 18:58:12 Temperature Measurement, Probe Number = 1, T = 27.943000 C 18:58:13 Temperature Measurement, Probe Number = 2, T = 23.950000 C 18:58:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.338330 V 18:58:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.338330 (V, A, ohm, ...), Measured Value = 28.587919 (C, atm, Hz, ...) 18:58:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.368577 V 18:58:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.368577 (V, A, ohm, ...), Measured Value = 29.008008 (C, atm, Hz, ...) 18:58:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664118 V 18:58:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664118 (V, A, ohm, ...), Measured Value = 124.808880 (C, atm, Hz, ...) 18:58:15 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105122 V 18:58:15 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105122 (V, A, ohm, ...), Measured Value = 7.884165 (C, atm, Hz, ...) 18:58:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.99 P1 = MAIN (V), Value = 8.54 P2 = Coil, Value = 28.59 P3 = Magnet Core, Value = 27.94 P4 = Ambient Temp (C), Value = 23.95 P5 = Supply Temp(C), Value = 28.59 P6 = Return Temp(C), Value = 29.01 P7 = Supply Pres(psi), Value = 124.81 P8 = Return Pres(psi), Value = 7.88 18:58:16 Magnetic Field Measurement Measuring the magnet strength... 18:58:16 Integrated Voltage Measurement... 18:58:16 Magnet Current for MAIN, Imag = 119.9903 A Vtrans = 1.199878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:58:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055818165 Vs 18:58:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055851564 Vs 18:58:34 Magnet Current for MAIN, Imag = 119.9901 A Vtrans = 1.199877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055823384 Vs 18:58:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055873707 Vs 18:58:50 Magnet Current for MAIN, Imag = 119.9904 A Vtrans = 1.199879 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:58:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055808080 Vs 18:59:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055864479 Vs 18:59:07 Magnet Current for MAIN, Imag = 119.9899 A Vtrans = 1.199874 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:59:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055809116 Vs 18:59:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055870455 Vs 18:59:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055839869 +- 0.000005320 Vs 18:59:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.055839869 +- 0.000005320 Vs BL = 0.62044299 +- 0.00005911 Tm 18:59:27 Position moved: 0.000000 m 18:59:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.62044 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.62044 0.00006 0.62044 0.00000 18:59:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.62044 0.00006 SL = 0.6204430 +- 0.0000591 Tm^2/m^n 18:59:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6204430 +- 0.0000591 Tm^2/m^n 18:59:30 Position moved: 0.000000 m 18:59:30 Magnet system MAIN current ramping to 130.0000 A... 18:59:46 Magnet Current for MAIN, Imag = 129.9783 A Vtrans = 1.299758 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 18:59:47 MAIN (V) Voltage Measurement, V = 9.261683 V 18:59:47 Temperature Measurement, Probe Number = 0, T = 28.675000 C 18:59:48 Temperature Measurement, Probe Number = 1, T = 27.949000 C 18:59:49 Temperature Measurement, Probe Number = 2, T = 23.910000 C 18:59:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337917 V 18:59:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337917 (V, A, ohm, ...), Measured Value = 28.582182 (C, atm, Hz, ...) 18:59:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.376523 V 18:59:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.376523 (V, A, ohm, ...), Measured Value = 29.118381 (C, atm, Hz, ...) 18:59:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671815 V 18:59:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671815 (V, A, ohm, ...), Measured Value = 125.386103 (C, atm, Hz, ...) 18:59:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104624 V 18:59:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104624 (V, A, ohm, ...), Measured Value = 7.846792 (C, atm, Hz, ...) 18:59:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 129.98 P1 = MAIN (V), Value = 9.26 P2 = Coil, Value = 28.68 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.91 P5 = Supply Temp(C), Value = 28.58 P6 = Return Temp(C), Value = 29.12 P7 = Supply Pres(psi), Value = 125.39 P8 = Return Pres(psi), Value = 7.85 18:59:52 Magnetic Field Measurement Measuring the magnet strength... 18:59:52 Integrated Voltage Measurement... 18:59:52 Magnet Current for MAIN, Imag = 129.9783 A Vtrans = 1.299758 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:00:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060476200 Vs 19:00:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060501808 Vs 19:00:10 Magnet Current for MAIN, Imag = 129.9784 A Vtrans = 1.299759 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:00:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060478075 Vs 19:00:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060497602 Vs 19:00:27 Magnet Current for MAIN, Imag = 129.9785 A Vtrans = 1.299761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:00:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060450935 Vs 19:00:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060495548 Vs 19:00:43 Magnet Current for MAIN, Imag = 129.9785 A Vtrans = 1.299761 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:00:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060460965 Vs 19:00:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060498920 Vs 19:00:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060482507 +- 0.000006385 Vs 19:00:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.060482507 +- 0.000006385 Vs BL = 0.67202785 +- 0.00007094 Tm 19:01:03 Position moved: 0.000000 m 19:01:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.67203 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.67203 0.00007 0.67203 0.00000 19:01:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.67203 0.00007 SL = 0.6720279 +- 0.0000709 Tm^2/m^n 19:01:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6720279 +- 0.0000709 Tm^2/m^n 19:01:06 Position moved: 0.000000 m 19:01:06 Magnet system MAIN current ramping to 140.0000 A... 19:01:22 Magnet Current for MAIN, Imag = 139.9688 A Vtrans = 1.399664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:01:23 MAIN (V) Voltage Measurement, V = 9.981125 V 19:01:24 Temperature Measurement, Probe Number = 0, T = 28.735000 C 19:01:24 Temperature Measurement, Probe Number = 1, T = 27.953000 C 19:01:25 Temperature Measurement, Probe Number = 2, T = 23.918000 C 19:01:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337630 V 19:01:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337630 (V, A, ohm, ...), Measured Value = 28.578192 (C, atm, Hz, ...) 19:01:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.385437 V 19:01:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.385437 (V, A, ohm, ...), Measured Value = 29.242186 (C, atm, Hz, ...) 19:01:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.674800 V 19:01:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.674800 (V, A, ohm, ...), Measured Value = 125.610037 (C, atm, Hz, ...) 19:01:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104906 V 19:01:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104906 (V, A, ohm, ...), Measured Value = 7.867958 (C, atm, Hz, ...) 19:01:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.97 P1 = MAIN (V), Value = 9.98 P2 = Coil, Value = 28.73 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.92 P5 = Supply Temp(C), Value = 28.58 P6 = Return Temp(C), Value = 29.24 P7 = Supply Pres(psi), Value = 125.61 P8 = Return Pres(psi), Value = 7.87 19:01:28 Magnetic Field Measurement Measuring the magnet strength... 19:01:28 Integrated Voltage Measurement... 19:01:28 Magnet Current for MAIN, Imag = 139.9685 A Vtrans = 1.399661 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:01:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065080712 Vs 19:01:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065127800 Vs 19:01:46 Magnet Current for MAIN, Imag = 139.9689 A Vtrans = 1.399665 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:01:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065082173 Vs 19:02:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065122524 Vs 19:02:03 Magnet Current for MAIN, Imag = 139.9688 A Vtrans = 1.399664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:02:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065106077 Vs 19:02:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065121972 Vs 19:02:19 Magnet Current for MAIN, Imag = 139.9692 A Vtrans = 1.399667 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:02:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065104866 Vs 19:02:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065117035 Vs 19:02:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065107895 +- 0.000004768 Vs 19:02:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.065107895 +- 0.000004768 Vs BL = 0.72342106 +- 0.00005297 Tm 19:02:39 Position moved: 0.000000 m 19:02:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72342 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.72342 0.00005 0.72342 0.00000 19:02:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72342 0.00005 SL = 0.7234211 +- 0.0000530 Tm^2/m^n 19:02:39 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7234211 +- 0.0000530 Tm^2/m^n 19:02:42 Position moved: 0.000000 m 19:02:42 Magnet system MAIN current ramping to 150.0000 A... 19:02:58 Magnet Current for MAIN, Imag = 149.9556 A Vtrans = 1.499532 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:02:59 MAIN (V) Voltage Measurement, V = 10.702091 V 19:03:00 Temperature Measurement, Probe Number = 0, T = 28.819000 C 19:03:00 Temperature Measurement, Probe Number = 1, T = 27.951000 C 19:03:01 Temperature Measurement, Probe Number = 2, T = 23.872000 C 19:03:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337495 V 19:03:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337495 (V, A, ohm, ...), Measured Value = 28.576321 (C, atm, Hz, ...) 19:03:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.394812 V 19:03:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.394812 (V, A, ohm, ...), Measured Value = 29.372383 (C, atm, Hz, ...) 19:03:03 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660745 V 19:03:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660745 (V, A, ohm, ...), Measured Value = 124.555868 (C, atm, Hz, ...) 19:03:04 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105043 V 19:03:04 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105043 (V, A, ohm, ...), Measured Value = 7.878255 (C, atm, Hz, ...) 19:03:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.96 P1 = MAIN (V), Value = 10.70 P2 = Coil, Value = 28.82 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.87 P5 = Supply Temp(C), Value = 28.58 P6 = Return Temp(C), Value = 29.37 P7 = Supply Pres(psi), Value = 124.56 P8 = Return Pres(psi), Value = 7.88 19:03:04 Magnetic Field Measurement Measuring the magnet strength... 19:03:04 Integrated Voltage Measurement... 19:03:04 Magnet Current for MAIN, Imag = 149.9558 A Vtrans = 1.499533 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:03:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.069703193 Vs 19:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.069770838 Vs 19:03:22 Magnet Current for MAIN, Imag = 149.9555 A Vtrans = 1.499531 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:03:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.069711575 Vs 19:03:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.069749675 Vs 19:03:39 Magnet Current for MAIN, Imag = 149.9561 A Vtrans = 1.499537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:03:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.069725067 Vs 19:03:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.069742865 Vs 19:03:55 Magnet Current for MAIN, Imag = 149.9561 A Vtrans = 1.499537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:04:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.069734335 Vs 19:04:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.069767521 Vs 19:04:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.069738134 +- 0.000007725 Vs 19:04:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.069738134 +- 0.000007725 Vs BL = 0.77486815 +- 0.00008583 Tm 19:04:15 Position moved: 0.000000 m 19:04:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.77487 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.77487 0.00009 0.77487 0.00000 19:04:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.77487 0.00009 SL = 0.7748682 +- 0.0000858 Tm^2/m^n 19:04:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7748682 +- 0.0000858 Tm^2/m^n 19:04:18 Position moved: 0.000000 m 19:04:18 Magnet system MAIN current ramping to 160.0000 A... 19:04:34 Magnet Current for MAIN, Imag = 159.9792 A Vtrans = 1.599768 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:04:35 MAIN (V) Voltage Measurement, V = 11.427542 V 19:04:36 Temperature Measurement, Probe Number = 0, T = 28.907000 C 19:04:36 Temperature Measurement, Probe Number = 1, T = 27.945000 C 19:04:37 Temperature Measurement, Probe Number = 2, T = 23.854000 C 19:04:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.337034 V 19:04:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.337034 (V, A, ohm, ...), Measured Value = 28.569913 (C, atm, Hz, ...) 19:04:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.404892 V 19:04:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.404892 (V, A, ohm, ...), Measured Value = 29.512396 (C, atm, Hz, ...) 19:04:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651072 V 19:04:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651072 (V, A, ohm, ...), Measured Value = 123.830407 (C, atm, Hz, ...) 19:04:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104883 V 19:04:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104883 (V, A, ohm, ...), Measured Value = 7.866240 (C, atm, Hz, ...) 19:04:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 159.98 P1 = MAIN (V), Value = 11.43 P2 = Coil, Value = 28.91 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.85 P5 = Supply Temp(C), Value = 28.57 P6 = Return Temp(C), Value = 29.51 P7 = Supply Pres(psi), Value = 123.83 P8 = Return Pres(psi), Value = 7.87 19:04:40 Magnetic Field Measurement Measuring the magnet strength... 19:04:40 Integrated Voltage Measurement... 19:04:41 Magnet Current for MAIN, Imag = 159.9795 A Vtrans = 1.599770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:04:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074358680 Vs 19:04:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074400246 Vs 19:04:58 Magnet Current for MAIN, Imag = 159.9796 A Vtrans = 1.599771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:05:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074371441 Vs 19:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074417799 Vs 19:05:15 Magnet Current for MAIN, Imag = 159.9791 A Vtrans = 1.599766 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:05:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074362814 Vs 19:05:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074385052 Vs 19:05:31 Magnet Current for MAIN, Imag = 159.9792 A Vtrans = 1.599768 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:05:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074363061 Vs 19:05:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074399405 Vs 19:05:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074382312 +- 0.000007599 Vs 19:05:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.074382312 +- 0.000007599 Vs BL = 0.82647014 +- 0.00008443 Tm 19:05:51 Position moved: 0.000000 m 19:05:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.82647 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.82647 0.00008 0.82647 0.00000 19:05:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.82647 0.00008 SL = 0.8264701 +- 0.0000844 Tm^2/m^n 19:05:51 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8264701 +- 0.0000844 Tm^2/m^n 19:05:54 Position moved: 0.000000 m 19:05:54 Magnet system MAIN current ramping to 170.0000 A... 19:06:10 Magnet Current for MAIN, Imag = 169.9696 A Vtrans = 1.699672 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:06:11 MAIN (V) Voltage Measurement, V = 12.152617 V 19:06:12 Temperature Measurement, Probe Number = 0, T = 28.994000 C 19:06:12 Temperature Measurement, Probe Number = 1, T = 27.945000 C 19:06:13 Temperature Measurement, Probe Number = 2, T = 23.826000 C 19:06:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336645 V 19:06:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336645 (V, A, ohm, ...), Measured Value = 28.564510 (C, atm, Hz, ...) 19:06:14 Sensor Voltage Measurement, Sensor Number = 1, V = 2.416304 V 19:06:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.416304 (V, A, ohm, ...), Measured Value = 29.670894 (C, atm, Hz, ...) 19:06:15 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667044 V 19:06:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667044 (V, A, ohm, ...), Measured Value = 125.028330 (C, atm, Hz, ...) 19:06:16 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105017 V 19:06:16 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105017 (V, A, ohm, ...), Measured Value = 7.876252 (C, atm, Hz, ...) 19:06:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 169.97 P1 = MAIN (V), Value = 12.15 P2 = Coil, Value = 28.99 P3 = Magnet Core, Value = 27.95 P4 = Ambient Temp (C), Value = 23.83 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.67 P7 = Supply Pres(psi), Value = 125.03 P8 = Return Pres(psi), Value = 7.88 19:06:16 Magnetic Field Measurement Measuring the magnet strength... 19:06:16 Integrated Voltage Measurement... 19:06:16 Magnet Current for MAIN, Imag = 169.9702 A Vtrans = 1.699678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:06:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.078998421 Vs 19:06:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079015734 Vs 19:06:34 Magnet Current for MAIN, Imag = 169.9701 A Vtrans = 1.699677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:06:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.078999174 Vs 19:06:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079027827 Vs 19:06:50 Magnet Current for MAIN, Imag = 169.9701 A Vtrans = 1.699677 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:06:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.078993855 Vs 19:07:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079041550 Vs 19:07:07 Magnet Current for MAIN, Imag = 169.9699 A Vtrans = 1.699674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:07:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079010845 Vs 19:07:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079013389 Vs 19:07:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079012599 +- 0.000003794 Vs 19:07:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.079012599 +- 0.000003794 Vs BL = 0.87791777 +- 0.00004215 Tm 19:07:27 Position moved: 0.000000 m 19:07:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.87792 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.87792 0.00004 0.87792 0.00000 19:07:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.87792 0.00004 SL = 0.8779178 +- 0.0000422 Tm^2/m^n 19:07:27 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8779178 +- 0.0000422 Tm^2/m^n 19:07:29 Position moved: 0.000000 m 19:07:30 Magnet system MAIN current ramping to 180.0000 A... 19:07:46 Magnet Current for MAIN, Imag = 180.0302 A Vtrans = 1.800277 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:07:47 MAIN (V) Voltage Measurement, V = 12.884846 V 19:07:47 Temperature Measurement, Probe Number = 0, T = 29.097000 C 19:07:48 Temperature Measurement, Probe Number = 1, T = 27.965000 C 19:07:49 Temperature Measurement, Probe Number = 2, T = 23.803000 C 19:07:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.336226 V 19:07:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.336226 (V, A, ohm, ...), Measured Value = 28.558701 (C, atm, Hz, ...) 19:07:50 Sensor Voltage Measurement, Sensor Number = 1, V = 2.429456 V 19:07:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.429456 (V, A, ohm, ...), Measured Value = 29.853558 (C, atm, Hz, ...) 19:07:51 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663982 V 19:07:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663982 (V, A, ohm, ...), Measured Value = 124.798672 (C, atm, Hz, ...) 19:07:51 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105266 V 19:07:51 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105266 (V, A, ohm, ...), Measured Value = 7.894935 (C, atm, Hz, ...) 19:07:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.03 P1 = MAIN (V), Value = 12.88 P2 = Coil, Value = 29.10 P3 = Magnet Core, Value = 27.96 P4 = Ambient Temp (C), Value = 23.80 P5 = Supply Temp(C), Value = 28.56 P6 = Return Temp(C), Value = 29.85 P7 = Supply Pres(psi), Value = 124.80 P8 = Return Pres(psi), Value = 7.89 19:07:51 Magnetic Field Measurement Measuring the magnet strength... 19:07:51 Integrated Voltage Measurement... 19:07:52 Magnet Current for MAIN, Imag = 180.0304 A Vtrans = 1.800280 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:08:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083630765 Vs 19:08:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083695950 Vs 19:08:10 Magnet Current for MAIN, Imag = 180.0303 A Vtrans = 1.800279 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:08:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083656664 Vs 19:08:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083703033 Vs 19:08:26 Magnet Current for MAIN, Imag = 180.0303 A Vtrans = 1.800279 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:08:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083636992 Vs 19:08:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083690962 Vs 19:08:43 Magnet Current for MAIN, Imag = 180.0306 A Vtrans = 1.800281 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:08:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083656542 Vs 19:08:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083681671 Vs 19:08:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083669072 +- 0.000006610 Vs 19:08:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.083669072 +- 0.000006610 Vs BL = 0.92965636 +- 0.00007344 Tm 19:09:02 Position moved: 0.000000 m 19:09:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.92966 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.92966 0.00007 0.92966 0.00000 19:09:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.92966 0.00007 SL = 0.9296564 +- 0.0000734 Tm^2/m^n 19:09:02 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9296564 +- 0.0000734 Tm^2/m^n 19:09:05 Position moved: 0.000000 m 19:09:05 Magnet system MAIN current ramping to 190.0000 A... 19:09:22 Magnet Current for MAIN, Imag = 190.0269 A Vtrans = 1.900245 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:09:22 MAIN (V) Voltage Measurement, V = 13.614864 V 19:09:23 Temperature Measurement, Probe Number = 0, T = 29.211000 C 19:09:24 Temperature Measurement, Probe Number = 1, T = 27.975000 C 19:09:24 Temperature Measurement, Probe Number = 2, T = 23.762000 C 19:09:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335737 V 19:09:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335737 (V, A, ohm, ...), Measured Value = 28.551906 (C, atm, Hz, ...) 19:09:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.444100 V 19:09:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.444100 (V, A, ohm, ...), Measured Value = 30.056947 (C, atm, Hz, ...) 19:09:26 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664240 V 19:09:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664240 (V, A, ohm, ...), Measured Value = 124.818030 (C, atm, Hz, ...) 19:09:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105186 V 19:09:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105186 (V, A, ohm, ...), Measured Value = 7.888928 (C, atm, Hz, ...) 19:09:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 190.03 P1 = MAIN (V), Value = 13.61 P2 = Coil, Value = 29.21 P3 = Magnet Core, Value = 27.98 P4 = Ambient Temp (C), Value = 23.76 P5 = Supply Temp(C), Value = 28.55 P6 = Return Temp(C), Value = 30.06 P7 = Supply Pres(psi), Value = 124.82 P8 = Return Pres(psi), Value = 7.89 19:09:27 Magnetic Field Measurement Measuring the magnet strength... 19:09:27 Integrated Voltage Measurement... 19:09:28 Magnet Current for MAIN, Imag = 190.0272 A Vtrans = 1.900247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:09:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088264538 Vs 19:09:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088317834 Vs 19:09:45 Magnet Current for MAIN, Imag = 190.0268 A Vtrans = 1.900244 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:09:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088250085 Vs 19:10:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088308801 Vs 19:10:02 Magnet Current for MAIN, Imag = 190.0271 A Vtrans = 1.900246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088269670 Vs 19:10:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088312971 Vs 19:10:19 Magnet Current for MAIN, Imag = 190.0272 A Vtrans = 1.900247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:10:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088279757 Vs 19:10:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088313043 Vs 19:10:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088289587 +- 0.000006223 Vs 19:10:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.088289587 +- 0.000006223 Vs BL = 0.98099542 +- 0.00006914 Tm 19:10:38 Position moved: 0.000000 m 19:10:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.98100 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.98100 0.00007 0.98100 0.00000 19:10:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.98100 0.00007 SL = 0.9809954 +- 0.0000691 Tm^2/m^n 19:10:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9809954 +- 0.0000691 Tm^2/m^n 19:10:41 Position moved: 0.000000 m 19:10:41 Magnet system MAIN current ramping to 200.0000 A... 19:10:57 Magnet Current for MAIN, Imag = 200.0268 A Vtrans = 2.000243 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:10:58 MAIN (V) Voltage Measurement, V = 14.347425 V 19:10:59 Temperature Measurement, Probe Number = 0, T = 29.319000 C 19:10:59 Temperature Measurement, Probe Number = 1, T = 28.002000 C 19:11:00 Temperature Measurement, Probe Number = 2, T = 23.734000 C 19:11:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.335306 V 19:11:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.335306 (V, A, ohm, ...), Measured Value = 28.545921 (C, atm, Hz, ...) 19:11:01 Sensor Voltage Measurement, Sensor Number = 1, V = 2.460178 V 19:11:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.460178 (V, A, ohm, ...), Measured Value = 30.280250 (C, atm, Hz, ...) 19:11:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.671723 V 19:11:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671723 (V, A, ohm, ...), Measured Value = 125.379240 (C, atm, Hz, ...) 19:11:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105140 V 19:11:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105140 (V, A, ohm, ...), Measured Value = 7.885500 (C, atm, Hz, ...) 19:11:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.03 P1 = MAIN (V), Value = 14.35 P2 = Coil, Value = 29.32 P3 = Magnet Core, Value = 28.00 P4 = Ambient Temp (C), Value = 23.73 P5 = Supply Temp(C), Value = 28.55 P6 = Return Temp(C), Value = 30.28 P7 = Supply Pres(psi), Value = 125.38 P8 = Return Pres(psi), Value = 7.89 19:11:02 Magnetic Field Measurement Measuring the magnet strength... 19:11:03 Integrated Voltage Measurement... 19:11:03 Magnet Current for MAIN, Imag = 200.0273 A Vtrans = 2.000248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.092897705 Vs 19:11:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.092920175 Vs 19:11:21 Magnet Current for MAIN, Imag = 200.0270 A Vtrans = 2.000246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:11:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.092905012 Vs 19:11:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.092927900 Vs 19:11:37 Magnet Current for MAIN, Imag = 200.0266 A Vtrans = 2.000242 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:11:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.092891982 Vs 19:11:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.092926941 Vs 19:11:54 Magnet Current for MAIN, Imag = 200.0271 A Vtrans = 2.000247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:12:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.092923491 Vs 19:12:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.092885054 Vs 19:12:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.092909782 +- 0.000004350 Vs 19:12:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.092909782 +- 0.000004350 Vs BL = 1.03233091 +- 0.00004834 Tm 19:12:13 Position moved: 0.000000 m 19:12:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 1.03233 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 1.03233 0.00005 1.03233 0.00000 19:12:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 1.03233 0.00005 SL = 1.0323309 +- 0.0000483 Tm^2/m^n 19:12:13 Magnet Strength Measurement Harmonic Number = 1 SL = 1.0323309 +- 0.0000483 Tm^2/m^n 19:12:16 Position moved: 0.000000 m 19:12:16 Magnet system MAIN current ramping to 190.0000 A... 19:12:33 Magnet Current for MAIN, Imag = 190.0274 A Vtrans = 1.900250 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:12:34 MAIN (V) Voltage Measurement, V = 13.640094 V 19:12:34 Temperature Measurement, Probe Number = 0, T = 29.435000 C 19:12:35 Temperature Measurement, Probe Number = 1, T = 28.023000 C 19:12:35 Temperature Measurement, Probe Number = 2, T = 23.704000 C 19:12:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334722 V 19:12:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334722 (V, A, ohm, ...), Measured Value = 28.537800 (C, atm, Hz, ...) 19:12:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.476765 V 19:12:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.476765 (V, A, ohm, ...), Measured Value = 30.510632 (C, atm, Hz, ...) 19:12:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651640 V 19:12:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651640 (V, A, ohm, ...), Measured Value = 123.873015 (C, atm, Hz, ...) 19:12:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104990 V 19:12:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104990 (V, A, ohm, ...), Measured Value = 7.874250 (C, atm, Hz, ...) 19:12:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 190.03 P1 = MAIN (V), Value = 13.64 P2 = Coil, Value = 29.43 P3 = Magnet Core, Value = 28.02 P4 = Ambient Temp (C), Value = 23.70 P5 = Supply Temp(C), Value = 28.54 P6 = Return Temp(C), Value = 30.51 P7 = Supply Pres(psi), Value = 123.87 P8 = Return Pres(psi), Value = 7.87 19:12:38 Magnetic Field Measurement Measuring the magnet strength... 19:12:38 Integrated Voltage Measurement... 19:12:39 Magnet Current for MAIN, Imag = 190.0272 A Vtrans = 1.900247 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:12:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088436014 Vs 19:12:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088460924 Vs 19:12:56 Magnet Current for MAIN, Imag = 190.0269 A Vtrans = 1.900245 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:13:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088438453 Vs 19:13:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088431157 Vs 19:13:13 Magnet Current for MAIN, Imag = 190.0269 A Vtrans = 1.900245 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:13:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088435353 Vs 19:13:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088448522 Vs 19:13:30 Magnet Current for MAIN, Imag = 190.0271 A Vtrans = 1.900246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:13:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088429497 Vs 19:13:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.088446272 Vs 19:13:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.088440774 +- 0.000005112 Vs 19:13:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.088440774 +- 0.000005112 Vs BL = 0.98267527 +- 0.00005680 Tm 19:13:49 Position moved: 0.000000 m 19:13:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.98268 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.98268 0.00006 0.98268 0.00000 19:13:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.98268 0.00006 SL = 0.9826753 +- 0.0000568 Tm^2/m^n 19:13:49 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9826753 +- 0.0000568 Tm^2/m^n 19:13:52 Position moved: 0.000000 m 19:13:52 Magnet system MAIN current ramping to 180.0000 A... 19:14:09 Magnet Current for MAIN, Imag = 180.0304 A Vtrans = 1.800280 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:14:09 MAIN (V) Voltage Measurement, V = 12.912765 V 19:14:10 Temperature Measurement, Probe Number = 0, T = 29.444000 C 19:14:10 Temperature Measurement, Probe Number = 1, T = 28.049000 C 19:14:11 Temperature Measurement, Probe Number = 2, T = 23.695000 C 19:14:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334376 V 19:14:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334376 (V, A, ohm, ...), Measured Value = 28.532999 (C, atm, Hz, ...) 19:14:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.494215 V 19:14:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.494215 (V, A, ohm, ...), Measured Value = 30.752983 (C, atm, Hz, ...) 19:14:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664619 V 19:14:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664619 (V, A, ohm, ...), Measured Value = 124.846440 (C, atm, Hz, ...) 19:14:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105188 V 19:14:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105188 (V, A, ohm, ...), Measured Value = 7.889123 (C, atm, Hz, ...) 19:14:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.03 P1 = MAIN (V), Value = 12.91 P2 = Coil, Value = 29.44 P3 = Magnet Core, Value = 28.05 P4 = Ambient Temp (C), Value = 23.70 P5 = Supply Temp(C), Value = 28.53 P6 = Return Temp(C), Value = 30.75 P7 = Supply Pres(psi), Value = 124.85 P8 = Return Pres(psi), Value = 7.89 19:14:14 Magnetic Field Measurement Measuring the magnet strength... 19:14:14 Integrated Voltage Measurement... 19:14:15 Magnet Current for MAIN, Imag = 180.0307 A Vtrans = 1.800283 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:14:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083895366 Vs 19:14:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083937343 Vs 19:14:32 Magnet Current for MAIN, Imag = 180.0307 A Vtrans = 1.800283 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:14:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083892157 Vs 19:14:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083939628 Vs 19:14:49 Magnet Current for MAIN, Imag = 180.0306 A Vtrans = 1.800281 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:14:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083902577 Vs 19:15:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083928725 Vs 19:15:05 Magnet Current for MAIN, Imag = 180.0303 A Vtrans = 1.800279 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:15:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083916892 Vs 19:15:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.083953348 Vs 19:15:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.083920754 +- 0.000008298 Vs 19:15:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.083920754 +- 0.000008298 Vs BL = 0.93245283 +- 0.00009220 Tm 19:15:25 Position moved: 0.000000 m 19:15:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.93245 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.93245 0.00009 0.93245 0.00000 19:15:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.93245 0.00009 SL = 0.9324528 +- 0.0000922 Tm^2/m^n 19:15:25 Magnet Strength Measurement Harmonic Number = 1 SL = 0.9324528 +- 0.0000922 Tm^2/m^n 19:15:28 Position moved: 0.000000 m 19:15:28 Magnet system MAIN current ramping to 170.0000 A... 19:15:44 Magnet Current for MAIN, Imag = 169.9702 A Vtrans = 1.699678 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:15:45 MAIN (V) Voltage Measurement, V = 12.178648 V 19:15:46 Temperature Measurement, Probe Number = 0, T = 29.390000 C 19:15:46 Temperature Measurement, Probe Number = 1, T = 28.061000 C 19:15:47 Temperature Measurement, Probe Number = 2, T = 23.641000 C 19:15:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334344 V 19:15:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334344 (V, A, ohm, ...), Measured Value = 28.532557 (C, atm, Hz, ...) 19:15:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.508878 V 19:15:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.508878 (V, A, ohm, ...), Measured Value = 30.956637 (C, atm, Hz, ...) 19:15:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659346 V 19:15:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659346 (V, A, ohm, ...), Measured Value = 124.450913 (C, atm, Hz, ...) 19:15:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105188 V 19:15:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105188 (V, A, ohm, ...), Measured Value = 7.889123 (C, atm, Hz, ...) 19:15:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 169.97 P1 = MAIN (V), Value = 12.18 P2 = Coil, Value = 29.39 P3 = Magnet Core, Value = 28.06 P4 = Ambient Temp (C), Value = 23.64 P5 = Supply Temp(C), Value = 28.53 P6 = Return Temp(C), Value = 30.96 P7 = Supply Pres(psi), Value = 124.45 P8 = Return Pres(psi), Value = 7.89 19:15:50 Magnetic Field Measurement Measuring the magnet strength... 19:15:50 Integrated Voltage Measurement... 19:15:50 Magnet Current for MAIN, Imag = 169.9708 A Vtrans = 1.699683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:15:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079310890 Vs 19:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079379115 Vs 19:16:08 Magnet Current for MAIN, Imag = 169.9705 A Vtrans = 1.699680 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079327293 Vs 19:16:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079364668 Vs 19:16:25 Magnet Current for MAIN, Imag = 169.9708 A Vtrans = 1.699683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:16:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079326079 Vs 19:16:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079378911 Vs 19:16:41 Magnet Current for MAIN, Imag = 169.9709 A Vtrans = 1.699684 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:16:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079304928 Vs 19:16:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.079352538 Vs 19:16:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.079343053 +- 0.000008755 Vs 19:16:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.079343053 +- 0.000008755 Vs BL = 0.88158947 +- 0.00009728 Tm 19:17:01 Position moved: 0.000000 m 19:17:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.88159 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.88159 0.00010 0.88159 0.00000 19:17:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.88159 0.00010 SL = 0.8815895 +- 0.0000973 Tm^2/m^n 19:17:01 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8815895 +- 0.0000973 Tm^2/m^n 19:17:04 Position moved: 0.000000 m 19:17:04 Magnet system MAIN current ramping to 160.0000 A... 19:17:20 Magnet Current for MAIN, Imag = 159.9796 A Vtrans = 1.599771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:17:21 MAIN (V) Voltage Measurement, V = 11.450684 V 19:17:21 Temperature Measurement, Probe Number = 0, T = 29.324000 C 19:17:22 Temperature Measurement, Probe Number = 1, T = 28.073000 C 19:17:23 Temperature Measurement, Probe Number = 2, T = 23.602000 C 19:17:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.334231 V 19:17:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.334231 (V, A, ohm, ...), Measured Value = 28.530986 (C, atm, Hz, ...) 19:17:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.518068 V 19:17:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.518068 (V, A, ohm, ...), Measured Value = 31.084279 (C, atm, Hz, ...) 19:17:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668009 V 19:17:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668009 (V, A, ohm, ...), Measured Value = 125.100682 (C, atm, Hz, ...) 19:17:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105272 V 19:17:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105272 (V, A, ohm, ...), Measured Value = 7.895415 (C, atm, Hz, ...) 19:17:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 159.98 P1 = MAIN (V), Value = 11.45 P2 = Coil, Value = 29.32 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 23.60 P5 = Supply Temp(C), Value = 28.53 P6 = Return Temp(C), Value = 31.08 P7 = Supply Pres(psi), Value = 125.10 P8 = Return Pres(psi), Value = 7.90 19:17:25 Magnetic Field Measurement Measuring the magnet strength... 19:17:25 Integrated Voltage Measurement... 19:17:26 Magnet Current for MAIN, Imag = 159.9796 A Vtrans = 1.599771 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074756315 Vs 19:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074784475 Vs 19:17:44 Magnet Current for MAIN, Imag = 159.9795 A Vtrans = 1.599770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:17:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074778559 Vs 19:17:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074765569 Vs 19:18:00 Magnet Current for MAIN, Imag = 159.9798 A Vtrans = 1.599774 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:18:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074759099 Vs 19:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074766032 Vs 19:18:17 Magnet Current for MAIN, Imag = 159.9798 A Vtrans = 1.599774 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:18:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074765302 Vs 19:18:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.074757925 Vs 19:18:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.074766659 +- 0.000004620 Vs 19:18:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.074766659 +- 0.000004620 Vs BL = 0.83074066 +- 0.00005133 Tm 19:18:36 Position moved: 0.000000 m 19:18:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.83074 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.83074 0.00005 0.83074 0.00000 19:18:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.83074 0.00005 SL = 0.8307407 +- 0.0000513 Tm^2/m^n 19:18:36 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8307407 +- 0.0000513 Tm^2/m^n 19:18:39 Position moved: 0.000000 m 19:18:39 Magnet system MAIN current ramping to 150.0000 A... 19:18:56 Magnet Current for MAIN, Imag = 149.9565 A Vtrans = 1.499541 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:18:56 MAIN (V) Voltage Measurement, V = 10.722427 V 19:18:57 Temperature Measurement, Probe Number = 0, T = 29.208000 C 19:18:58 Temperature Measurement, Probe Number = 1, T = 28.085000 C 19:18:58 Temperature Measurement, Probe Number = 2, T = 23.556000 C 19:18:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333903 V 19:18:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333903 (V, A, ohm, ...), Measured Value = 28.526431 (C, atm, Hz, ...) 19:19:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.521520 V 19:19:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.521520 (V, A, ohm, ...), Measured Value = 31.132226 (C, atm, Hz, ...) 19:19:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663061 V 19:19:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663061 (V, A, ohm, ...), Measured Value = 124.729560 (C, atm, Hz, ...) 19:19:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105382 V 19:19:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105382 (V, A, ohm, ...), Measured Value = 7.903613 (C, atm, Hz, ...) 19:19:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 149.96 P1 = MAIN (V), Value = 10.72 P2 = Coil, Value = 29.21 P3 = Magnet Core, Value = 28.09 P4 = Ambient Temp (C), Value = 23.56 P5 = Supply Temp(C), Value = 28.53 P6 = Return Temp(C), Value = 31.13 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 7.90 19:19:01 Magnetic Field Measurement Measuring the magnet strength... 19:19:01 Integrated Voltage Measurement... 19:19:02 Magnet Current for MAIN, Imag = 149.9569 A Vtrans = 1.499545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:19:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070166386 Vs 19:19:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070153377 Vs 19:19:19 Magnet Current for MAIN, Imag = 149.9568 A Vtrans = 1.499543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:19:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070164480 Vs 19:19:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070158878 Vs 19:19:36 Magnet Current for MAIN, Imag = 149.9566 A Vtrans = 1.499542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:19:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070178271 Vs 19:19:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070179032 Vs 19:19:52 Magnet Current for MAIN, Imag = 149.9569 A Vtrans = 1.499545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:20:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070179369 Vs 19:20:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070186179 Vs 19:20:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070170746 +- 0.000010092 Vs 19:20:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.070170746 +- 0.000010092 Vs BL = 0.77967496 +- 0.00011214 Tm 19:20:12 Position moved: 0.000000 m 19:20:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.77967 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.77967 0.00011 0.77967 0.00000 19:20:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.77967 0.00011 SL = 0.7796750 +- 0.0001121 Tm^2/m^n 19:20:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7796750 +- 0.0001121 Tm^2/m^n 19:20:15 Position moved: 0.000000 m 19:20:15 Magnet system MAIN current ramping to 140.0000 A... 19:20:31 Magnet Current for MAIN, Imag = 139.9698 A Vtrans = 1.399674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:20:32 MAIN (V) Voltage Measurement, V = 9.998634 V 19:20:33 Temperature Measurement, Probe Number = 0, T = 29.090000 C 19:20:33 Temperature Measurement, Probe Number = 1, T = 28.071000 C 19:20:34 Temperature Measurement, Probe Number = 2, T = 23.561000 C 19:20:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333822 V 19:20:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333822 (V, A, ohm, ...), Measured Value = 28.525301 (C, atm, Hz, ...) 19:20:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.519593 V 19:20:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.519593 (V, A, ohm, ...), Measured Value = 31.105464 (C, atm, Hz, ...) 19:20:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664500 V 19:20:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664500 (V, A, ohm, ...), Measured Value = 124.837477 (C, atm, Hz, ...) 19:20:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104951 V 19:20:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104951 (V, A, ohm, ...), Measured Value = 7.871295 (C, atm, Hz, ...) 19:20:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.97 P1 = MAIN (V), Value = 10.00 P2 = Coil, Value = 29.09 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 23.56 P5 = Supply Temp(C), Value = 28.53 P6 = Return Temp(C), Value = 31.11 P7 = Supply Pres(psi), Value = 124.84 P8 = Return Pres(psi), Value = 7.87 19:20:37 Magnetic Field Measurement Measuring the magnet strength... 19:20:37 Integrated Voltage Measurement... 19:20:37 Magnet Current for MAIN, Imag = 139.9701 A Vtrans = 1.399676 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:20:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065561298 Vs 19:20:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065592606 Vs 19:20:55 Magnet Current for MAIN, Imag = 139.9697 A Vtrans = 1.399673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:21:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065542850 Vs 19:21:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065598021 Vs 19:21:11 Magnet Current for MAIN, Imag = 139.9697 A Vtrans = 1.399673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:21:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065566384 Vs 19:21:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065595876 Vs 19:21:28 Magnet Current for MAIN, Imag = 139.9698 A Vtrans = 1.399674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065539101 Vs 19:21:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.065579828 Vs 19:21:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.065571995 +- 0.000008177 Vs 19:21:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.065571995 +- 0.000008177 Vs BL = 0.72857773 +- 0.00009086 Tm 19:21:47 Position moved: 0.000000 m 19:21:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.72858 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.72858 0.00009 0.72858 0.00000 19:21:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.72858 0.00009 SL = 0.7285777 +- 0.0000909 Tm^2/m^n 19:21:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7285777 +- 0.0000909 Tm^2/m^n 19:21:50 Position moved: 0.000000 m 19:21:50 Magnet system MAIN current ramping to 130.0000 A... 19:22:07 Magnet Current for MAIN, Imag = 129.9788 A Vtrans = 1.299763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:22:07 MAIN (V) Voltage Measurement, V = 9.276637 V 19:22:08 Temperature Measurement, Probe Number = 0, T = 29.023000 C 19:22:09 Temperature Measurement, Probe Number = 1, T = 28.093000 C 19:22:09 Temperature Measurement, Probe Number = 2, T = 23.546000 C 19:22:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333538 V 19:22:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333538 (V, A, ohm, ...), Measured Value = 28.521364 (C, atm, Hz, ...) 19:22:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.512898 V 19:22:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.512898 (V, A, ohm, ...), Measured Value = 31.012476 (C, atm, Hz, ...) 19:22:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663902 V 19:22:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663902 (V, A, ohm, ...), Measured Value = 124.792673 (C, atm, Hz, ...) 19:22:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105134 V 19:22:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105134 (V, A, ohm, ...), Measured Value = 7.885020 (C, atm, Hz, ...) 19:22:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 129.98 P1 = MAIN (V), Value = 9.28 P2 = Coil, Value = 29.02 P3 = Magnet Core, Value = 28.09 P4 = Ambient Temp (C), Value = 23.55 P5 = Supply Temp(C), Value = 28.52 P6 = Return Temp(C), Value = 31.01 P7 = Supply Pres(psi), Value = 124.79 P8 = Return Pres(psi), Value = 7.89 19:22:12 Magnetic Field Measurement Measuring the magnet strength... 19:22:12 Integrated Voltage Measurement... 19:22:13 Magnet Current for MAIN, Imag = 129.9794 A Vtrans = 1.299770 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060940121 Vs 19:22:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060982986 Vs 19:22:30 Magnet Current for MAIN, Imag = 129.9793 A Vtrans = 1.299768 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:22:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060954276 Vs 19:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060955036 Vs 19:22:46 Magnet Current for MAIN, Imag = 129.9790 A Vtrans = 1.299766 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060937790 Vs 19:23:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060974025 Vs 19:23:03 Magnet Current for MAIN, Imag = 129.9788 A Vtrans = 1.299763 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060945332 Vs 19:23:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.060977936 Vs 19:23:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.060958438 +- 0.000003187 Vs 19:23:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.060958438 +- 0.000003187 Vs BL = 0.67731597 +- 0.00003541 Tm 19:23:22 Position moved: 0.000000 m 19:23:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.67732 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.67732 0.00004 0.67732 0.00000 19:23:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.67732 0.00004 SL = 0.6773160 +- 0.0000354 Tm^2/m^n 19:23:22 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6773160 +- 0.0000354 Tm^2/m^n 19:23:25 Position moved: 0.000000 m 19:23:25 Magnet system MAIN current ramping to 120.0000 A... 19:23:42 Magnet Current for MAIN, Imag = 119.9908 A Vtrans = 1.199883 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:23:42 MAIN (V) Voltage Measurement, V = 8.556441 V 19:23:43 Temperature Measurement, Probe Number = 0, T = 28.932000 C 19:23:44 Temperature Measurement, Probe Number = 1, T = 28.093000 C 19:23:44 Temperature Measurement, Probe Number = 2, T = 23.541000 C 19:23:45 Sensor Voltage Measurement, Sensor Number = 0, V = 2.333189 V 19:23:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333189 (V, A, ohm, ...), Measured Value = 28.516510 (C, atm, Hz, ...) 19:23:46 Sensor Voltage Measurement, Sensor Number = 1, V = 2.501980 V 19:23:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.501980 (V, A, ohm, ...), Measured Value = 30.860831 (C, atm, Hz, ...) 19:23:46 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660075 V 19:23:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660075 (V, A, ohm, ...), Measured Value = 124.505632 (C, atm, Hz, ...) 19:23:47 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105059 V 19:23:47 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105059 (V, A, ohm, ...), Measured Value = 7.879395 (C, atm, Hz, ...) 19:23:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 119.99 P1 = MAIN (V), Value = 8.56 P2 = Coil, Value = 28.93 P3 = Magnet Core, Value = 28.09 P4 = Ambient Temp (C), Value = 23.54 P5 = Supply Temp(C), Value = 28.52 P6 = Return Temp(C), Value = 30.86 P7 = Supply Pres(psi), Value = 124.51 P8 = Return Pres(psi), Value = 7.88 19:23:47 Magnetic Field Measurement Measuring the magnet strength... 19:23:47 Integrated Voltage Measurement... 19:23:48 Magnet Current for MAIN, Imag = 119.9908 A Vtrans = 1.199883 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.056314059 Vs 19:24:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.056361533 Vs 19:24:05 Magnet Current for MAIN, Imag = 119.9906 A Vtrans = 1.199882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:24:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.056323841 Vs 19:24:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.056373510 Vs 19:24:22 Magnet Current for MAIN, Imag = 119.9906 A Vtrans = 1.199882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:24:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.056324396 Vs 19:24:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.056369711 Vs 19:24:38 Magnet Current for MAIN, Imag = 119.9906 A Vtrans = 1.199882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:24:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.056329948 Vs 19:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.056367938 Vs 19:24:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.056345617 +- 0.000004573 Vs 19:24:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.056345617 +- 0.000004573 Vs BL = 0.62606241 +- 0.00005081 Tm 19:24:58 Position moved: 0.000000 m 19:24:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.62606 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.62606 0.00005 0.62606 0.00000 19:24:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.62606 0.00005 SL = 0.6260624 +- 0.0000508 Tm^2/m^n 19:24:58 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6260624 +- 0.0000508 Tm^2/m^n 19:25:01 Position moved: 0.000000 m 19:25:01 Magnet system MAIN current ramping to 110.0000 A... 19:25:17 Magnet Current for MAIN, Imag = 109.9886 A Vtrans = 1.099861 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:25:18 MAIN (V) Voltage Measurement, V = 7.836968 V 19:25:18 Temperature Measurement, Probe Number = 0, T = 28.835000 C 19:25:19 Temperature Measurement, Probe Number = 1, T = 28.074000 C 19:25:20 Temperature Measurement, Probe Number = 2, T = 23.482000 C 19:25:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332657 V 19:25:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332657 (V, A, ohm, ...), Measured Value = 28.509131 (C, atm, Hz, ...) 19:25:21 Sensor Voltage Measurement, Sensor Number = 1, V = 2.488998 V 19:25:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.488998 (V, A, ohm, ...), Measured Value = 30.680532 (C, atm, Hz, ...) 19:25:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.672861 V 19:25:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672861 (V, A, ohm, ...), Measured Value = 125.464560 (C, atm, Hz, ...) 19:25:22 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104862 V 19:25:22 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104862 (V, A, ohm, ...), Measured Value = 7.864620 (C, atm, Hz, ...) 19:25:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 109.99 P1 = MAIN (V), Value = 7.84 P2 = Coil, Value = 28.84 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 23.48 P5 = Supply Temp(C), Value = 28.51 P6 = Return Temp(C), Value = 30.68 P7 = Supply Pres(psi), Value = 125.46 P8 = Return Pres(psi), Value = 7.86 19:25:22 Magnetic Field Measurement Measuring the magnet strength... 19:25:22 Integrated Voltage Measurement... 19:25:23 Magnet Current for MAIN, Imag = 109.9889 A Vtrans = 1.099865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:25:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051662598 Vs 19:25:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051736740 Vs 19:25:41 Magnet Current for MAIN, Imag = 109.9887 A Vtrans = 1.099862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:25:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051661143 Vs 19:25:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051746162 Vs 19:25:57 Magnet Current for MAIN, Imag = 109.9887 A Vtrans = 1.099862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:26:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051684882 Vs 19:26:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051745433 Vs 19:26:14 Magnet Current for MAIN, Imag = 109.9887 A Vtrans = 1.099862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:26:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051677524 Vs 19:26:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.051741226 Vs 19:26:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.051706963 +- 0.000005855 Vs 19:26:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.051706963 +- 0.000005855 Vs BL = 0.57452181 +- 0.00006506 Tm 19:26:33 Position moved: 0.000000 m 19:26:33 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.57452 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.57452 0.00007 0.57452 0.00000 19:26:33 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.57452 0.00007 SL = 0.5745218 +- 0.0000651 Tm^2/m^n 19:26:33 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5745218 +- 0.0000651 Tm^2/m^n 19:26:36 Position moved: 0.000000 m 19:26:36 Magnet system MAIN current ramping to 100.0000 A... 19:26:53 Magnet Current for MAIN, Imag = 100.0005 A Vtrans = 0.999981 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:26:53 MAIN (V) Voltage Measurement, V = 7.120078 V 19:26:54 Temperature Measurement, Probe Number = 0, T = 28.742000 C 19:26:55 Temperature Measurement, Probe Number = 1, T = 28.069000 C 19:26:55 Temperature Measurement, Probe Number = 2, T = 23.466000 C 19:26:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.332322 V 19:26:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.332322 (V, A, ohm, ...), Measured Value = 28.504469 (C, atm, Hz, ...) 19:26:57 Sensor Voltage Measurement, Sensor Number = 1, V = 2.474422 V 19:26:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.474422 (V, A, ohm, ...), Measured Value = 30.478079 (C, atm, Hz, ...) 19:26:57 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656638 V 19:26:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656638 (V, A, ohm, ...), Measured Value = 124.247857 (C, atm, Hz, ...) 19:26:58 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104977 V 19:26:58 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104977 (V, A, ohm, ...), Measured Value = 7.873298 (C, atm, Hz, ...) 19:26:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.00 P1 = MAIN (V), Value = 7.12 P2 = Coil, Value = 28.74 P3 = Magnet Core, Value = 28.07 P4 = Ambient Temp (C), Value = 23.47 P5 = Supply Temp(C), Value = 28.50 P6 = Return Temp(C), Value = 30.48 P7 = Supply Pres(psi), Value = 124.25 P8 = Return Pres(psi), Value = 7.87 19:26:58 Magnetic Field Measurement Measuring the magnet strength... 19:26:58 Integrated Voltage Measurement... 19:26:59 Magnet Current for MAIN, Imag = 100.0008 A Vtrans = 0.999983 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047033514 Vs 19:27:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047102566 Vs 19:27:16 Magnet Current for MAIN, Imag = 100.0006 A Vtrans = 0.999982 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047048097 Vs 19:27:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047108564 Vs 19:27:32 Magnet Current for MAIN, Imag = 100.0004 A Vtrans = 0.999980 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:27:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047047413 Vs 19:27:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047085163 Vs 19:27:49 Magnet Current for MAIN, Imag = 100.0002 A Vtrans = 0.999977 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:27:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047044666 Vs 19:28:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047106531 Vs 19:28:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047072064 +- 0.000005033 Vs 19:28:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.047072064 +- 0.000005033 Vs BL = 0.52302294 +- 0.00005592 Tm 19:28:09 Position moved: 0.000000 m 19:28:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.52302 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.52302 0.00006 0.52302 0.00000 19:28:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.52302 0.00006 SL = 0.5230229 +- 0.0000559 Tm^2/m^n 19:28:09 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5230229 +- 0.0000559 Tm^2/m^n 19:28:12 Position moved: 0.000000 m 19:28:12 Magnet system MAIN current ramping to 90.0000 A... 19:28:28 Magnet Current for MAIN, Imag = 90.0097 A Vtrans = 0.900072 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:28:29 MAIN (V) Voltage Measurement, V = 6.404399 V 19:28:29 Temperature Measurement, Probe Number = 0, T = 28.629000 C 19:28:30 Temperature Measurement, Probe Number = 1, T = 28.056000 C 19:28:31 Temperature Measurement, Probe Number = 2, T = 23.458000 C 19:28:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.331977 V 19:28:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331977 (V, A, ohm, ...), Measured Value = 28.499685 (C, atm, Hz, ...) 19:28:32 Sensor Voltage Measurement, Sensor Number = 1, V = 2.459080 V 19:28:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.459080 (V, A, ohm, ...), Measured Value = 30.264997 (C, atm, Hz, ...) 19:28:33 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660962 V 19:28:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660962 (V, A, ohm, ...), Measured Value = 124.572172 (C, atm, Hz, ...) 19:28:33 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104864 V 19:28:33 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104864 (V, A, ohm, ...), Measured Value = 7.864815 (C, atm, Hz, ...) 19:28:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 90.01 P1 = MAIN (V), Value = 6.40 P2 = Coil, Value = 28.63 P3 = Magnet Core, Value = 28.06 P4 = Ambient Temp (C), Value = 23.46 P5 = Supply Temp(C), Value = 28.50 P6 = Return Temp(C), Value = 30.26 P7 = Supply Pres(psi), Value = 124.57 P8 = Return Pres(psi), Value = 7.86 19:28:33 Magnetic Field Measurement Measuring the magnet strength... 19:28:33 Integrated Voltage Measurement... 19:28:34 Magnet Current for MAIN, Imag = 90.0097 A Vtrans = 0.900073 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:28:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.042396615 Vs 19:28:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.042463811 Vs 19:28:52 Magnet Current for MAIN, Imag = 90.0098 A Vtrans = 0.900074 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:28:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.042395178 Vs 19:29:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.042454509 Vs 19:29:08 Magnet Current for MAIN, Imag = 90.0098 A Vtrans = 0.900073 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:29:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.042403831 Vs 19:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.042440750 Vs 19:29:24 Magnet Current for MAIN, Imag = 90.0096 A Vtrans = 0.900071 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.042419630 Vs 19:29:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.042445750 Vs 19:29:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.042427509 +- 0.000004138 Vs 19:29:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.042427509 +- 0.000004138 Vs BL = 0.47141677 +- 0.00004598 Tm 19:29:44 Position moved: 0.000000 m 19:29:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.47142 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.47142 0.00005 0.47142 0.00000 19:29:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.47142 0.00005 SL = 0.4714168 +- 0.0000460 Tm^2/m^n 19:29:44 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4714168 +- 0.0000460 Tm^2/m^n 19:29:47 Position moved: 0.000000 m 19:29:47 Magnet system MAIN current ramping to 80.0000 A... 19:30:03 Magnet Current for MAIN, Imag = 79.9445 A Vtrans = 0.799420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:30:04 MAIN (V) Voltage Measurement, V = 5.684831 V 19:30:05 Temperature Measurement, Probe Number = 0, T = 28.542000 C 19:30:05 Temperature Measurement, Probe Number = 1, T = 28.049000 C 19:30:06 Temperature Measurement, Probe Number = 2, T = 23.420000 C 19:30:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.331979 V 19:30:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331979 (V, A, ohm, ...), Measured Value = 28.499703 (C, atm, Hz, ...) 19:30:07 Sensor Voltage Measurement, Sensor Number = 1, V = 2.443557 V 19:30:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.443557 (V, A, ohm, ...), Measured Value = 30.049410 (C, atm, Hz, ...) 19:30:08 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670427 V 19:30:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670427 (V, A, ohm, ...), Measured Value = 125.282003 (C, atm, Hz, ...) 19:30:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104541 V 19:30:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104541 (V, A, ohm, ...), Measured Value = 7.840597 (C, atm, Hz, ...) 19:30:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 79.94 P1 = MAIN (V), Value = 5.68 P2 = Coil, Value = 28.54 P3 = Magnet Core, Value = 28.05 P4 = Ambient Temp (C), Value = 23.42 P5 = Supply Temp(C), Value = 28.50 P6 = Return Temp(C), Value = 30.05 P7 = Supply Pres(psi), Value = 125.28 P8 = Return Pres(psi), Value = 7.84 19:30:09 Magnetic Field Measurement Measuring the magnet strength... 19:30:09 Integrated Voltage Measurement... 19:30:09 Magnet Current for MAIN, Imag = 79.9444 A Vtrans = 0.799420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:30:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037741832 Vs 19:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037759633 Vs 19:30:27 Magnet Current for MAIN, Imag = 79.9446 A Vtrans = 0.799421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:30:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037743310 Vs 19:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037761081 Vs 19:30:43 Magnet Current for MAIN, Imag = 79.9443 A Vtrans = 0.799418 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:30:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037747392 Vs 19:30:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037761002 Vs 19:30:59 Magnet Current for MAIN, Imag = 79.9444 A Vtrans = 0.799420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:31:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037743268 Vs 19:31:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.037749237 Vs 19:31:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.037750845 +- 0.000002922 Vs 19:31:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.037750845 +- 0.000002922 Vs BL = 0.41945383 +- 0.00003247 Tm 19:31:19 Position moved: 0.000000 m 19:31:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.41945 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.41945 0.00003 0.41945 0.00000 19:31:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.41945 0.00003 SL = 0.4194538 +- 0.0000325 Tm^2/m^n 19:31:19 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4194538 +- 0.0000325 Tm^2/m^n 19:31:22 Position moved: 0.000000 m 19:31:22 Magnet system MAIN current ramping to 70.0000 A... 19:31:39 Magnet Current for MAIN, Imag = 69.9369 A Vtrans = 0.699345 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:31:39 MAIN (V) Voltage Measurement, V = 4.970491 V 19:31:40 Temperature Measurement, Probe Number = 0, T = 28.478000 C 19:31:41 Temperature Measurement, Probe Number = 1, T = 28.043000 C 19:31:41 Temperature Measurement, Probe Number = 2, T = 23.390000 C 19:31:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.331455 V 19:31:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331455 (V, A, ohm, ...), Measured Value = 28.492429 (C, atm, Hz, ...) 19:31:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.428514 V 19:31:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.428514 (V, A, ohm, ...), Measured Value = 29.840476 (C, atm, Hz, ...) 19:31:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668251 V 19:31:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668251 (V, A, ohm, ...), Measured Value = 125.118795 (C, atm, Hz, ...) 19:31:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104333 V 19:31:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104333 (V, A, ohm, ...), Measured Value = 7.824960 (C, atm, Hz, ...) 19:31:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 69.94 P1 = MAIN (V), Value = 4.97 P2 = Coil, Value = 28.48 P3 = Magnet Core, Value = 28.04 P4 = Ambient Temp (C), Value = 23.39 P5 = Supply Temp(C), Value = 28.49 P6 = Return Temp(C), Value = 29.84 P7 = Supply Pres(psi), Value = 125.12 P8 = Return Pres(psi), Value = 7.82 19:31:44 Magnetic Field Measurement Measuring the magnet strength... 19:31:44 Integrated Voltage Measurement... 19:31:45 Magnet Current for MAIN, Imag = 69.9371 A Vtrans = 0.699346 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:31:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.033084317 Vs 19:32:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.033094682 Vs 19:32:02 Magnet Current for MAIN, Imag = 69.9371 A Vtrans = 0.699346 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.033086092 Vs 19:32:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.033093537 Vs 19:32:19 Magnet Current for MAIN, Imag = 69.9371 A Vtrans = 0.699347 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:32:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.033084638 Vs 19:32:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.033094677 Vs 19:32:35 Magnet Current for MAIN, Imag = 69.9373 A Vtrans = 0.699349 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:32:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.033082352 Vs 19:32:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.033095525 Vs 19:32:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.033089477 +- 0.000000330 Vs 19:32:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.033089477 +- 0.000000330 Vs BL = 0.36766086 +- 0.00000367 Tm 19:32:55 Position moved: 0.000000 m 19:32:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.36766 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.36766 0.00000 0.36766 0.00000 19:32:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.36766 0.00000 SL = 0.3676609 +- 0.0000037 Tm^2/m^n 19:32:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3676609 +- 0.0000037 Tm^2/m^n 19:32:57 Position moved: 0.000000 m 19:32:57 Magnet system MAIN current ramping to 60.0000 A... 19:33:14 Magnet Current for MAIN, Imag = 59.9443 A Vtrans = 0.599419 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:33:15 MAIN (V) Voltage Measurement, V = 4.258205 V 19:33:15 Temperature Measurement, Probe Number = 0, T = 28.419000 C 19:33:16 Temperature Measurement, Probe Number = 1, T = 28.020000 C 19:33:16 Temperature Measurement, Probe Number = 2, T = 23.353000 C 19:33:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.331016 V 19:33:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.331016 (V, A, ohm, ...), Measured Value = 28.486339 (C, atm, Hz, ...) 19:33:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.413868 V 19:33:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.413868 (V, A, ohm, ...), Measured Value = 29.637051 (C, atm, Hz, ...) 19:33:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669196 V 19:33:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669196 (V, A, ohm, ...), Measured Value = 125.189722 (C, atm, Hz, ...) 19:33:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104388 V 19:33:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104388 (V, A, ohm, ...), Measured Value = 7.829063 (C, atm, Hz, ...) 19:33:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.94 P1 = MAIN (V), Value = 4.26 P2 = Coil, Value = 28.42 P3 = Magnet Core, Value = 28.02 P4 = Ambient Temp (C), Value = 23.35 P5 = Supply Temp(C), Value = 28.49 P6 = Return Temp(C), Value = 29.64 P7 = Supply Pres(psi), Value = 125.19 P8 = Return Pres(psi), Value = 7.83 19:33:19 Magnetic Field Measurement Measuring the magnet strength... 19:33:19 Integrated Voltage Measurement... 19:33:20 Magnet Current for MAIN, Imag = 59.9444 A Vtrans = 0.599420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:33:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.028414517 Vs 19:33:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.028442811 Vs 19:33:37 Magnet Current for MAIN, Imag = 59.9446 A Vtrans = 0.599421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.028422630 Vs 19:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.028455695 Vs 19:33:54 Magnet Current for MAIN, Imag = 59.9445 A Vtrans = 0.599421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.028406394 Vs 19:34:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.028448698 Vs 19:34:10 Magnet Current for MAIN, Imag = 59.9443 A Vtrans = 0.599418 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:34:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.028411876 Vs 19:34:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.028442283 Vs 19:34:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.028430613 +- 0.000004970 Vs 19:34:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.028430613 +- 0.000004970 Vs BL = 0.31589570 +- 0.00005522 Tm 19:34:30 Position moved: 0.000000 m 19:34:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.31590 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.31590 0.00006 0.31590 0.00000 19:34:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.31590 0.00006 SL = 0.3158957 +- 0.0000552 Tm^2/m^n 19:34:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3158957 +- 0.0000552 Tm^2/m^n 19:34:33 Position moved: 0.000000 m 19:34:33 Magnet system MAIN current ramping to 50.0000 A... 19:34:50 Magnet Current for MAIN, Imag = 49.9530 A Vtrans = 0.499505 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:34:50 MAIN (V) Voltage Measurement, V = 3.546939 V 19:34:51 Temperature Measurement, Probe Number = 0, T = 28.354000 C 19:34:52 Temperature Measurement, Probe Number = 1, T = 28.010000 C 19:34:52 Temperature Measurement, Probe Number = 2, T = 23.326000 C 19:34:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330457 V 19:34:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330457 (V, A, ohm, ...), Measured Value = 28.478571 (C, atm, Hz, ...) 19:34:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.399682 V 19:34:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.399682 (V, A, ohm, ...), Measured Value = 29.440032 (C, atm, Hz, ...) 19:34:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657364 V 19:34:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657364 (V, A, ohm, ...), Measured Value = 124.302292 (C, atm, Hz, ...) 19:34:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104150 V 19:34:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104150 (V, A, ohm, ...), Measured Value = 7.811235 (C, atm, Hz, ...) 19:34:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 49.95 P1 = MAIN (V), Value = 3.55 P2 = Coil, Value = 28.35 P3 = Magnet Core, Value = 28.01 P4 = Ambient Temp (C), Value = 23.33 P5 = Supply Temp(C), Value = 28.48 P6 = Return Temp(C), Value = 29.44 P7 = Supply Pres(psi), Value = 124.30 P8 = Return Pres(psi), Value = 7.81 19:34:55 Magnetic Field Measurement Measuring the magnet strength... 19:34:55 Integrated Voltage Measurement... 19:34:56 Magnet Current for MAIN, Imag = 49.9530 A Vtrans = 0.499505 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:35:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023763999 Vs 19:35:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023777327 Vs 19:35:13 Magnet Current for MAIN, Imag = 49.9529 A Vtrans = 0.499505 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:35:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023766872 Vs 19:35:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023777789 Vs 19:35:30 Magnet Current for MAIN, Imag = 49.9529 A Vtrans = 0.499505 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023770262 Vs 19:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023785053 Vs 19:35:46 Magnet Current for MAIN, Imag = 49.9529 A Vtrans = 0.499504 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:35:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023762583 Vs 19:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023782217 Vs 19:36:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023773263 +- 0.000002631 Vs 19:36:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.023773263 +- 0.000002631 Vs BL = 0.26414737 +- 0.00002923 Tm 19:36:06 Position moved: 0.000000 m 19:36:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.26415 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.26415 0.00003 0.26415 0.00000 19:36:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.26415 0.00003 SL = 0.2641474 +- 0.0000292 Tm^2/m^n 19:36:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2641474 +- 0.0000292 Tm^2/m^n 19:36:09 Position moved: 0.000000 m 19:36:09 Magnet system MAIN current ramping to 40.0000 A... 19:36:26 Magnet Current for MAIN, Imag = 39.9662 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:36:26 MAIN (V) Voltage Measurement, V = 2.836808 V 19:36:27 Temperature Measurement, Probe Number = 0, T = 28.299000 C 19:36:28 Temperature Measurement, Probe Number = 1, T = 27.982000 C 19:36:28 Temperature Measurement, Probe Number = 2, T = 23.296000 C 19:36:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330306 V 19:36:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330306 (V, A, ohm, ...), Measured Value = 28.476471 (C, atm, Hz, ...) 19:36:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.386350 V 19:36:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.386350 (V, A, ohm, ...), Measured Value = 29.254862 (C, atm, Hz, ...) 19:36:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662785 V 19:36:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662785 (V, A, ohm, ...), Measured Value = 124.708875 (C, atm, Hz, ...) 19:36:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104272 V 19:36:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104272 (V, A, ohm, ...), Measured Value = 7.820385 (C, atm, Hz, ...) 19:36:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.97 P1 = MAIN (V), Value = 2.84 P2 = Coil, Value = 28.30 P3 = Magnet Core, Value = 27.98 P4 = Ambient Temp (C), Value = 23.30 P5 = Supply Temp(C), Value = 28.48 P6 = Return Temp(C), Value = 29.25 P7 = Supply Pres(psi), Value = 124.71 P8 = Return Pres(psi), Value = 7.82 19:36:31 Magnetic Field Measurement Measuring the magnet strength... 19:36:31 Integrated Voltage Measurement... 19:36:32 Magnet Current for MAIN, Imag = 39.9662 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:36:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.019096636 Vs 19:36:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.019129793 Vs 19:36:49 Magnet Current for MAIN, Imag = 39.9662 A Vtrans = 0.399638 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:36:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.019105981 Vs 19:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.019130187 Vs 19:37:06 Magnet Current for MAIN, Imag = 39.9661 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.019094585 Vs 19:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.019137997 Vs 19:37:22 Magnet Current for MAIN, Imag = 39.9662 A Vtrans = 0.399637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.019092468 Vs 19:37:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.019138032 Vs 19:37:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.019115710 +- 0.000001762 Vs 19:37:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.019115710 +- 0.000001762 Vs BL = 0.21239678 +- 0.00001957 Tm 19:37:42 Position moved: 0.000000 m 19:37:42 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.21240 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.21240 0.00002 0.21240 0.00000 19:37:42 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.21240 0.00002 SL = 0.2123968 +- 0.0000196 Tm^2/m^n 19:37:42 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2123968 +- 0.0000196 Tm^2/m^n 19:37:45 Position moved: 0.000000 m 19:37:45 Magnet system MAIN current ramping to 30.0000 A... 19:38:01 Magnet Current for MAIN, Imag = 29.9676 A Vtrans = 0.299652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:38:02 MAIN (V) Voltage Measurement, V = 2.126509 V 19:38:03 Temperature Measurement, Probe Number = 0, T = 28.258000 C 19:38:03 Temperature Measurement, Probe Number = 1, T = 27.957000 C 19:38:04 Temperature Measurement, Probe Number = 2, T = 23.295000 C 19:38:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329984 V 19:38:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329984 (V, A, ohm, ...), Measured Value = 28.472004 (C, atm, Hz, ...) 19:38:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.374206 V 19:38:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.374206 (V, A, ohm, ...), Measured Value = 29.086197 (C, atm, Hz, ...) 19:38:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662823 V 19:38:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662823 (V, A, ohm, ...), Measured Value = 124.711733 (C, atm, Hz, ...) 19:38:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.104108 V 19:38:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.104108 (V, A, ohm, ...), Measured Value = 7.808093 (C, atm, Hz, ...) 19:38:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 29.97 P1 = MAIN (V), Value = 2.13 P2 = Coil, Value = 28.26 P3 = Magnet Core, Value = 27.96 P4 = Ambient Temp (C), Value = 23.30 P5 = Supply Temp(C), Value = 28.47 P6 = Return Temp(C), Value = 29.09 P7 = Supply Pres(psi), Value = 124.71 P8 = Return Pres(psi), Value = 7.81 19:38:07 Magnetic Field Measurement Measuring the magnet strength... 19:38:07 Integrated Voltage Measurement... 19:38:07 Magnet Current for MAIN, Imag = 29.9676 A Vtrans = 0.299651 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:38:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014429109 Vs 19:38:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014471682 Vs 19:38:25 Magnet Current for MAIN, Imag = 29.9676 A Vtrans = 0.299652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014430832 Vs 19:38:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014480422 Vs 19:38:42 Magnet Current for MAIN, Imag = 29.9677 A Vtrans = 0.299652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:38:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014429235 Vs 19:38:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014472578 Vs 19:38:58 Magnet Current for MAIN, Imag = 29.9676 A Vtrans = 0.299652 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:39:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014425862 Vs 19:39:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.014473580 Vs 19:39:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.014451663 +- 0.000002327 Vs 19:39:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.014451663 +- 0.000002327 Vs BL = 0.16057403 +- 0.00002586 Tm 19:39:18 Position moved: 0.000000 m 19:39:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.16057 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.16057 0.00003 0.16057 0.00000 19:39:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.16057 0.00003 SL = 0.1605740 +- 0.0000259 Tm^2/m^n 19:39:18 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1605740 +- 0.0000259 Tm^2/m^n 19:39:21 Position moved: 0.000000 m 19:39:21 Magnet system MAIN current ramping to 20.0000 A... 19:39:37 Magnet Current for MAIN, Imag = 19.9779 A Vtrans = 0.199754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:39:38 MAIN (V) Voltage Measurement, V = 1.417348 V 19:39:39 Temperature Measurement, Probe Number = 0, T = 28.224000 C 19:39:39 Temperature Measurement, Probe Number = 1, T = 27.937000 C 19:39:40 Temperature Measurement, Probe Number = 2, T = 23.266000 C 19:39:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.330024 V 19:39:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.330024 (V, A, ohm, ...), Measured Value = 28.472551 (C, atm, Hz, ...) 19:39:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.363308 V 19:39:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.363308 (V, A, ohm, ...), Measured Value = 28.934833 (C, atm, Hz, ...) 19:39:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661033 V 19:39:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661033 (V, A, ohm, ...), Measured Value = 124.577512 (C, atm, Hz, ...) 19:39:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103861 V 19:39:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103861 (V, A, ohm, ...), Measured Value = 7.789597 (C, atm, Hz, ...) 19:39:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 1.42 P2 = Coil, Value = 28.22 P3 = Magnet Core, Value = 27.94 P4 = Ambient Temp (C), Value = 23.27 P5 = Supply Temp(C), Value = 28.47 P6 = Return Temp(C), Value = 28.93 P7 = Supply Pres(psi), Value = 124.58 P8 = Return Pres(psi), Value = 7.79 19:39:43 Magnetic Field Measurement Measuring the magnet strength... 19:39:43 Integrated Voltage Measurement... 19:39:43 Magnet Current for MAIN, Imag = 19.9778 A Vtrans = 0.199753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:39:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009775588 Vs 19:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009811753 Vs 19:40:01 Magnet Current for MAIN, Imag = 19.9780 A Vtrans = 0.199755 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:40:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009776339 Vs 19:40:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009804704 Vs 19:40:18 Magnet Current for MAIN, Imag = 19.9777 A Vtrans = 0.199753 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:40:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009775059 Vs 19:40:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009809779 Vs 19:40:34 Magnet Current for MAIN, Imag = 19.9779 A Vtrans = 0.199754 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:40:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009773392 Vs 19:40:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.009807689 Vs 19:40:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.009791788 +- 0.000001333 Vs 19:40:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.009791788 +- 0.000001333 Vs BL = 0.10879764 +- 0.00001481 Tm 19:40:54 Position moved: 0.000000 m 19:40:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.10880 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.10880 0.00001 0.10880 0.00000 19:40:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.10880 0.00001 SL = 0.1087976 +- 0.0000148 Tm^2/m^n 19:40:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1087976 +- 0.0000148 Tm^2/m^n 19:40:57 Position moved: 0.000000 m 19:40:57 Magnet system MAIN current ramping to 10.0000 A... 19:41:13 Magnet Current for MAIN, Imag = 9.9901 A Vtrans = 0.099876 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:41:14 MAIN (V) Voltage Measurement, V = 0.708729 V 19:41:15 Temperature Measurement, Probe Number = 0, T = 28.197000 C 19:41:15 Temperature Measurement, Probe Number = 1, T = 27.923000 C 19:41:16 Temperature Measurement, Probe Number = 2, T = 23.238000 C 19:41:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329625 V 19:41:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329625 (V, A, ohm, ...), Measured Value = 28.467008 (C, atm, Hz, ...) 19:41:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.353350 V 19:41:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.353350 (V, A, ohm, ...), Measured Value = 28.796533 (C, atm, Hz, ...) 19:41:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669313 V 19:41:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669313 (V, A, ohm, ...), Measured Value = 125.198490 (C, atm, Hz, ...) 19:41:18 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103963 V 19:41:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103963 (V, A, ohm, ...), Measured Value = 7.797225 (C, atm, Hz, ...) 19:41:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 9.99 P1 = MAIN (V), Value = 0.71 P2 = Coil, Value = 28.20 P3 = Magnet Core, Value = 27.92 P4 = Ambient Temp (C), Value = 23.24 P5 = Supply Temp(C), Value = 28.47 P6 = Return Temp(C), Value = 28.80 P7 = Supply Pres(psi), Value = 125.20 P8 = Return Pres(psi), Value = 7.80 19:41:19 Magnetic Field Measurement Measuring the magnet strength... 19:41:19 Integrated Voltage Measurement... 19:41:19 Magnet Current for MAIN, Imag = 9.9899 A Vtrans = 0.099875 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005114114 Vs 19:41:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005151799 Vs 19:41:37 Magnet Current for MAIN, Imag = 9.9902 A Vtrans = 0.099878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:41:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005112848 Vs 19:41:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005151092 Vs 19:41:53 Magnet Current for MAIN, Imag = 9.9902 A Vtrans = 0.099878 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:42:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005114060 Vs 19:42:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005150418 Vs 19:42:10 Magnet Current for MAIN, Imag = 9.9902 A Vtrans = 0.099877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005115927 Vs 19:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.005145951 Vs 19:42:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.005132026 +- 0.000000724 Vs 19:42:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.005132026 +- 0.000000724 Vs BL = 0.05702251 +- 0.00000804 Tm 19:42:30 Position moved: 0.000000 m 19:42:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.05702 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.05702 0.00001 0.05702 0.00000 19:42:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.05702 0.00001 SL = 0.0570225 +- 0.0000080 Tm^2/m^n 19:42:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0570225 +- 0.0000080 Tm^2/m^n 19:42:33 Position moved: 0.000000 m 19:42:33 Magnet system MAIN current ramping to 0.0000 A... 19:42:49 Magnet Current for MAIN, Imag = 0.0070 A Vtrans = 0.000046 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:42:50 MAIN (V) Voltage Measurement, V = 0.000496 V 19:42:51 Temperature Measurement, Probe Number = 0, T = 28.172000 C 19:42:51 Temperature Measurement, Probe Number = 1, T = 27.893000 C 19:42:52 Temperature Measurement, Probe Number = 2, T = 23.211000 C 19:42:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.329650 V 19:42:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.329650 (V, A, ohm, ...), Measured Value = 28.467361 (C, atm, Hz, ...) 19:42:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.344283 V 19:42:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.344283 (V, A, ohm, ...), Measured Value = 28.670592 (C, atm, Hz, ...) 19:42:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666019 V 19:42:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666019 (V, A, ohm, ...), Measured Value = 124.951395 (C, atm, Hz, ...) 19:42:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.103619 V 19:42:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.103619 (V, A, ohm, ...), Measured Value = 7.771388 (C, atm, Hz, ...) 19:42:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Coil, Value = 28.17 P3 = Magnet Core, Value = 27.89 P4 = Ambient Temp (C), Value = 23.21 P5 = Supply Temp(C), Value = 28.47 P6 = Return Temp(C), Value = 28.67 P7 = Supply Pres(psi), Value = 124.95 P8 = Return Pres(psi), Value = 7.77 19:42:55 Magnetic Field Measurement Measuring the magnet strength... 19:42:55 Integrated Voltage Measurement... 19:42:56 Magnet Current for MAIN, Imag = 0.0072 A Vtrans = 0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:43:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000466579 Vs 19:43:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000483593 Vs 19:43:13 Magnet Current for MAIN, Imag = 0.0073 A Vtrans = 0.000048 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:43:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000463595 Vs 19:43:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000487408 Vs 19:43:30 Magnet Current for MAIN, Imag = 0.0072 A Vtrans = 0.000048 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000460240 Vs 19:43:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000489564 Vs 19:43:46 Magnet Current for MAIN, Imag = 0.0071 A Vtrans = 0.000047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.002447 A 19:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000457917 Vs 19:44:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000489353 Vs 19:44:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000474781 +- 0.000000696 Vs 19:44:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.000474781 +- 0.000000696 Vs BL = 0.00527535 +- 0.00000774 Tm 19:44:06 Position moved: 0.000000 m 19:44:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00528 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00528 0.00001 0.00528 0.00000 19:44:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00528 0.00001 SL = 0.0052753 +- 0.0000077 Tm^2/m^n 19:44:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0052753 +- 0.0000077 Tm^2/m^n 19:44:09 Position moved: 0.000000 m 19:44:12 Position moved: 0.000000 m 19:44:15 Magnet system MAIN current ramping to 0.0000 A...