SLAC Magnetic Measurements Date: 09-29-2022 Time: 14:59:23 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 67 Measurement Type: Long Coil Scans Operator: YL Comment: 2V; By field Center position: X0=0.000000, Y0=0.000000 Nominal Gap=25.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -0.544E-06 -7.769E-06 25.00000 25.00035 0 25.00015 0 25.00030 0 25.00015 0 1 -0.637E-06 -9.096E-06 25.00000 25.00035 0 25.00010 0 25.00035 0 25.00010 0 2 -0.787E-06 -11.236E-06 25.00000 25.00035 0 25.00005 0 25.00035 0 25.00010 0 3 -0.594E-06 -8.483E-06 25.00000 25.00030 0 25.00015 0 25.00035 0 25.00010 0 4 -0.668E-06 -9.535E-06 25.00000 25.00030 0 25.00015 0 25.00035 0 25.00010 0