SLAC Magnetic Measurements Date: 09-27-2022 Time: 16:58:41 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 62 Measurement Type: Long Coil Scans Operator: YL Comment: 2V-TW; Skew Quad Center position: X0=-0.001000, Y0=0.000000 Nominal Gap=15.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.470E-06 20.993E-06 15.00000 15.00040 0 15.00005 0 15.00055 0 15.00005 0 1 1.400E-06 19.995E-06 15.00000 15.00080 0 15.00010 0 15.00085 0 15.00010 0 2 1.453E-06 20.756E-06 15.00000 15.00095 0 15.00010 0 15.00110 0 15.00005 0 3 1.503E-06 21.467E-06 15.00000 15.00110 0 15.00010 0 15.00105 0 15.00015 0 4 1.392E-06 19.876E-06 15.00000 15.00115 0 15.00015 0 15.00115 0 15.00015 0