SLAC Magnetic Measurements Date: 10-04-2022 Time: 15:07:42 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 77 Measurement Type: Long Coil Scans Operator: YL Comment: Skew Quad, 4 Small Center position: X0=0.000000, Y0=0.000000 Nominal Gap=7.20 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 0.964E-06 13.774E-06 7.20000 7.19755 0 7.19885 0 7.19755 0 7.19885 0 1 0.845E-06 12.074E-06 7.20000 7.19740 0 7.19880 0 7.19745 0 7.19880 0 2 0.950E-06 13.565E-06 7.20000 7.19735 0 7.19875 0 7.19735 0 7.19870 0 3 0.958E-06 13.676E-06 7.20000 7.19730 0 7.19870 0 7.19730 0 7.19865 0 4 0.952E-06 13.604E-06 7.20000 7.19725 0 7.19865 0 7.19725 0 7.19865 0