SLAC Magnetic Measurements Date: 09-28-2022 Time: 12:26:43 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 64 Measurement Type: Long Coil Scans Operator: YL Comment: 2H-TW; Skew Quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=75.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 -6.092E-06 -87.017E-06 75.00000 75.00020 0 75.00020 0 75.00015 0 75.00020 0 1 -6.084E-06 -86.895E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00020 0 2 -6.103E-06 -87.172E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0 3 -6.128E-06 -87.528E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0 4 -6.020E-06 -85.989E-06 75.00000 75.00020 0 75.00015 0 75.00020 0 75.00015 0