SLAC Magnetic Measurements Date: 09-30-2022 Time: 19:00:08 Project: LCLS-II-HE Device Type: Undulator Data Type: Serial Number: HE_SXU_000 DATASET Number: 1 Tuning Stage: Tuning Run Number: 72 Measurement Type: Long Coil Scans Operator: YL Comment: +-25um; Normal quad Center position: X0=0.000000, Y0=0.000000 Nominal Gap=10.00 Scan Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap Number Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- 0 1.588E-06 22.674E-06 10.00000 10.00060 0 10.00060 0 10.00060 0 10.00060 0 1 1.604E-06 22.908E-06 10.00000 10.00060 0 10.00060 0 10.00060 0 10.00060 0 2 1.699E-06 24.272E-06 10.00000 10.00060 0 10.00060 0 10.00060 0 10.00060 0 3 1.659E-06 23.700E-06 10.00000 10.00060 0 10.00060 0 10.00060 0 10.00055 0 4 1.513E-06 21.606E-06 10.00000 10.00065 0 10.00060 0 10.00065 0 10.00060 0