SLAC Magnetic Measurements Date: 08-24-2026 Time: 09:23:14 Project: LCLS-II-HE Magnet Type: Phase Shifter Magnet Name: HE_SXPS_15081 Dataset Number: 6 Run Purpose: Final Results Run Type: Run Number: 2 Measurement Device: Stretched Wire Operator: YL Comment: 09:23:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:23:24 Motion Parameters, X Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:23:25 Motion Parameters, X Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:23:27 Motion Parameters, Y Controller, Axis 1 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:23:29 Motion Parameters, Y Controller, Axis 2 acc = 0.001000 m/s/s dcl = 0.001000 m/s/s vel = 0.001000 m/s pos = 0.000000 m kp = 188.600000 ki = 820.000000 kd = 491.400000 db = 0.000000 09:26:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:26:50 Integrated Voltage Measurement... 09:26:59 Voltage Offset Correction: v_off_ini = 1768.155 uV, v_off_fin = 1775.270 uV 09:26:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -129.691 uVs 09:26:59 Integrated Voltage Measurement... 09:27:08 Voltage Offset Correction: v_off_ini = 1768.731 uV, v_off_fin = 1761.979 uV 09:27:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.624 uVs 09:27:08 Integrated Voltage Measurement... 09:27:17 Voltage Offset Correction: v_off_ini = 1753.150 uV, v_off_fin = 1750.257 uV 09:27:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -103.832 uVs 09:27:17 Integrated Voltage Measurement... 09:27:26 Voltage Offset Correction: v_off_ini = 1763.831 uV, v_off_fin = 1766.958 uV 09:27:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 121.598 uVs 09:27:26 Integrated Voltage Measurement... 09:27:35 Voltage Offset Correction: v_off_ini = 1778.870 uV, v_off_fin = 1785.114 uV 09:27:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -95.642 uVs 09:27:35 Integrated Voltage Measurement... 09:27:44 Voltage Offset Correction: v_off_ini = 1767.028 uV, v_off_fin = 1758.607 uV 09:27:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 85.952 uVs 09:27:48 I1X Average and RMS of Measurements VT = -107.223 +- 11.826 uVs I1X = 21.445 +- 2.366 uTm 09:27:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:27:55 Integrated Voltage Measurement... 09:28:04 Voltage Offset Correction: v_off_ini = 1779.867 uV, v_off_fin = 1729.021 uV 09:28:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -313.481 uVs 09:28:04 Integrated Voltage Measurement... 09:28:13 Voltage Offset Correction: v_off_ini = 1736.716 uV, v_off_fin = 1762.512 uV 09:28:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.4999 mm VT = 302.131 uVs 09:28:13 Integrated Voltage Measurement... 09:28:22 Voltage Offset Correction: v_off_ini = 1728.622 uV, v_off_fin = 1727.860 uV 09:28:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -308.143 uVs 09:28:22 Integrated Voltage Measurement... 09:28:31 Voltage Offset Correction: v_off_ini = 1742.886 uV, v_off_fin = 1746.098 uV 09:28:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.904 uVs 09:28:31 Integrated Voltage Measurement... 09:28:40 Voltage Offset Correction: v_off_ini = 1753.405 uV, v_off_fin = 1722.695 uV 09:28:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.825 uVs 09:28:40 Integrated Voltage Measurement... 09:28:49 Voltage Offset Correction: v_off_ini = 1766.898 uV, v_off_fin = 1781.983 uV 09:28:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 321.798 uVs 09:28:53 I1Y Average and RMS of Measurements VT = -304.714 +- 4.377 uVs I1Y = -60.944 +- 0.876 uTm 09:28:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:29:01 Integrated Voltage Measurement... 09:29:10 Voltage Offset Correction: v_off_ini = 1737.476 uV, v_off_fin = 1752.040 uV 09:29:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.386 uVs 09:29:10 Integrated Voltage Measurement... 09:29:19 Voltage Offset Correction: v_off_ini = 1761.828 uV, v_off_fin = 1773.200 uV 09:29:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 96.875 uVs 09:29:19 Integrated Voltage Measurement... 09:29:28 Voltage Offset Correction: v_off_ini = 1750.514 uV, v_off_fin = 1740.285 uV 09:29:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.582 uVs 09:29:28 Integrated Voltage Measurement... 09:29:37 Voltage Offset Correction: v_off_ini = 1756.346 uV, v_off_fin = 1753.759 uV 09:29:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 98.461 uVs 09:29:37 Integrated Voltage Measurement... 09:29:46 Voltage Offset Correction: v_off_ini = 1757.178 uV, v_off_fin = 1748.481 uV 09:29:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.636 uVs 09:29:46 Integrated Voltage Measurement... 09:29:55 Voltage Offset Correction: v_off_ini = 1750.820 uV, v_off_fin = 1780.834 uV 09:29:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 105.994 uVs 09:29:57 I2X Average and RMS of Measurements VT = -90.989 +- 5.672 uVs I2X = 8.371 +- 0.522 uTm^2 09:30:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 09:30:05 Integrated Voltage Measurement... 09:30:14 Voltage Offset Correction: v_off_ini = 1772.966 uV, v_off_fin = 1759.067 uV 09:30:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.026 uVs 09:30:14 Integrated Voltage Measurement... 09:30:23 Voltage Offset Correction: v_off_ini = 1766.941 uV, v_off_fin = 1766.093 uV 09:30:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.728 uVs 09:30:23 Integrated Voltage Measurement... 09:30:32 Voltage Offset Correction: v_off_ini = 1774.510 uV, v_off_fin = 1780.171 uV 09:30:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.462 uVs 09:30:32 Integrated Voltage Measurement... 09:30:41 Voltage Offset Correction: v_off_ini = 1761.014 uV, v_off_fin = 1753.455 uV 09:30:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.088 uVs 09:30:41 Integrated Voltage Measurement... 09:30:50 Voltage Offset Correction: v_off_ini = 1755.407 uV, v_off_fin = 1749.059 uV 09:30:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -329.495 uVs 09:30:50 Integrated Voltage Measurement... 09:30:59 Voltage Offset Correction: v_off_ini = 1745.111 uV, v_off_fin = 1746.685 uV 09:30:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.942 uVs 09:31:02 I2Y Average and RMS of Measurements VT = -325.790 +- 1.015 uVs I2Y = -29.973 +- 0.093 uTm^2 09:31:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:31:10 Integrated Voltage Measurement... 09:31:19 Voltage Offset Correction: v_off_ini = 1786.032 uV, v_off_fin = 1783.670 uV 09:31:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -87.057 uVs 09:31:19 Integrated Voltage Measurement... 09:31:28 Voltage Offset Correction: v_off_ini = 1788.483 uV, v_off_fin = 1783.390 uV 09:31:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.376 uVs 09:31:28 Integrated Voltage Measurement... 09:31:37 Voltage Offset Correction: v_off_ini = 1783.457 uV, v_off_fin = 1787.917 uV 09:31:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.648 uVs 09:31:37 Integrated Voltage Measurement... 09:31:46 Voltage Offset Correction: v_off_ini = 1789.055 uV, v_off_fin = 1782.768 uV 09:31:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.275 uVs 09:31:46 Integrated Voltage Measurement... 09:31:55 Voltage Offset Correction: v_off_ini = 1791.320 uV, v_off_fin = 1783.101 uV 09:31:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.299 uVs 09:31:55 Integrated Voltage Measurement... 09:32:04 Voltage Offset Correction: v_off_ini = 1795.951 uV, v_off_fin = 1785.711 uV 09:32:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 66.220 uVs 09:32:09 I1X Average and RMS of Measurements VT = -77.146 +- 4.394 uVs I1X = 15.430 +- 0.878 uTm 09:32:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:32:15 Integrated Voltage Measurement... 09:32:24 Voltage Offset Correction: v_off_ini = 1753.777 uV, v_off_fin = 1755.923 uV 09:32:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -302.625 uVs 09:32:24 Integrated Voltage Measurement... 09:32:33 Voltage Offset Correction: v_off_ini = 1766.212 uV, v_off_fin = 1787.898 uV 09:32:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 299.225 uVs 09:32:33 Integrated Voltage Measurement... 09:32:42 Voltage Offset Correction: v_off_ini = 1754.230 uV, v_off_fin = 1747.274 uV 09:32:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.223 uVs 09:32:42 Integrated Voltage Measurement... 09:32:51 Voltage Offset Correction: v_off_ini = 1755.354 uV, v_off_fin = 1762.671 uV 09:32:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 318.265 uVs 09:32:51 Integrated Voltage Measurement... 09:33:00 Voltage Offset Correction: v_off_ini = 1763.486 uV, v_off_fin = 1752.212 uV 09:33:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.023 uVs 09:33:00 Integrated Voltage Measurement... 09:33:09 Voltage Offset Correction: v_off_ini = 1758.576 uV, v_off_fin = 1778.656 uV 09:33:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 331.869 uVs 09:33:13 I1Y Average and RMS of Measurements VT = -306.372 +- 4.006 uVs I1Y = -61.275 +- 0.800 uTm 09:33:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:33:21 Integrated Voltage Measurement... 09:33:30 Voltage Offset Correction: v_off_ini = 1784.798 uV, v_off_fin = 1762.650 uV 09:33:30 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -75.965 uVs 09:33:30 Integrated Voltage Measurement... 09:33:39 Voltage Offset Correction: v_off_ini = 1775.627 uV, v_off_fin = 1784.617 uV 09:33:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.033 uVs 09:33:39 Integrated Voltage Measurement... 09:33:48 Voltage Offset Correction: v_off_ini = 1783.163 uV, v_off_fin = 1762.414 uV 09:33:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.200 uVs 09:33:48 Integrated Voltage Measurement... 09:33:57 Voltage Offset Correction: v_off_ini = 1809.514 uV, v_off_fin = 1790.873 uV 09:33:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.468 uVs 09:33:57 Integrated Voltage Measurement... 09:34:06 Voltage Offset Correction: v_off_ini = 1779.027 uV, v_off_fin = 1782.205 uV 09:34:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.788 uVs 09:34:06 Integrated Voltage Measurement... 09:34:15 Voltage Offset Correction: v_off_ini = 1801.337 uV, v_off_fin = 1801.694 uV 09:34:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 58.234 uVs 09:34:18 I2X Average and RMS of Measurements VT = -61.781 +- 6.458 uVs I2X = 5.684 +- 0.594 uTm^2 09:34:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 09:34:25 Integrated Voltage Measurement... 09:34:34 Voltage Offset Correction: v_off_ini = 1758.557 uV, v_off_fin = 1748.530 uV 09:34:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.399 uVs 09:34:34 Integrated Voltage Measurement... 09:34:43 Voltage Offset Correction: v_off_ini = 1770.104 uV, v_off_fin = 1766.134 uV 09:34:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.613 uVs 09:34:43 Integrated Voltage Measurement... 09:34:52 Voltage Offset Correction: v_off_ini = 1767.026 uV, v_off_fin = 1769.355 uV 09:34:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.768 uVs 09:34:52 Integrated Voltage Measurement... 09:35:01 Voltage Offset Correction: v_off_ini = 1748.911 uV, v_off_fin = 1762.902 uV 09:35:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.768 uVs 09:35:01 Integrated Voltage Measurement... 09:35:10 Voltage Offset Correction: v_off_ini = 1766.137 uV, v_off_fin = 1785.229 uV 09:35:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.030 uVs 09:35:10 Integrated Voltage Measurement... 09:35:19 Voltage Offset Correction: v_off_ini = 1772.602 uV, v_off_fin = 1772.450 uV 09:35:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.583 uVs 09:35:22 I2Y Average and RMS of Measurements VT = -324.694 +- 7.510 uVs I2Y = -29.872 +- 0.691 uTm^2 09:35:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:35:31 Integrated Voltage Measurement... 09:35:40 Voltage Offset Correction: v_off_ini = 1772.446 uV, v_off_fin = 1790.599 uV 09:35:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -83.142 uVs 09:35:40 Integrated Voltage Measurement... 09:35:49 Voltage Offset Correction: v_off_ini = 1787.685 uV, v_off_fin = 1797.527 uV 09:35:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 87.663 uVs 09:35:49 Integrated Voltage Measurement... 09:35:58 Voltage Offset Correction: v_off_ini = 1786.463 uV, v_off_fin = 1791.092 uV 09:35:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -76.438 uVs 09:35:58 Integrated Voltage Measurement... 09:36:07 Voltage Offset Correction: v_off_ini = 1802.450 uV, v_off_fin = 1805.818 uV 09:36:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.442 uVs 09:36:07 Integrated Voltage Measurement... 09:36:16 Voltage Offset Correction: v_off_ini = 1796.955 uV, v_off_fin = 1799.318 uV 09:36:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.616 uVs 09:36:16 Integrated Voltage Measurement... 09:36:25 Voltage Offset Correction: v_off_ini = 1790.942 uV, v_off_fin = 1793.486 uV 09:36:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.127 uVs 09:36:29 I1X Average and RMS of Measurements VT = -73.738 +- 10.539 uVs I1X = 14.748 +- 2.108 uTm 09:36:31 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:36:36 Integrated Voltage Measurement... 09:36:44 Voltage Offset Correction: v_off_ini = 1809.990 uV, v_off_fin = 1811.765 uV 09:36:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -325.395 uVs 09:36:44 Integrated Voltage Measurement... 09:36:53 Voltage Offset Correction: v_off_ini = 1831.728 uV, v_off_fin = 1840.255 uV 09:36:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 321.796 uVs 09:36:53 Integrated Voltage Measurement... 09:37:02 Voltage Offset Correction: v_off_ini = 1838.290 uV, v_off_fin = 1821.073 uV 09:37:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -304.639 uVs 09:37:02 Integrated Voltage Measurement... 09:37:11 Voltage Offset Correction: v_off_ini = 1839.277 uV, v_off_fin = 1855.333 uV 09:37:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 310.580 uVs 09:37:11 Integrated Voltage Measurement... 09:37:20 Voltage Offset Correction: v_off_ini = 1836.055 uV, v_off_fin = 1814.153 uV 09:37:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -319.506 uVs 09:37:20 Integrated Voltage Measurement... 09:37:29 Voltage Offset Correction: v_off_ini = 1822.040 uV, v_off_fin = 1828.235 uV 09:37:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 323.848 uVs 09:37:34 I1Y Average and RMS of Measurements VT = -317.627 +- 7.127 uVs I1Y = -63.527 +- 1.426 uTm 09:37:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:37:41 Integrated Voltage Measurement... 09:37:50 Voltage Offset Correction: v_off_ini = 1801.877 uV, v_off_fin = 1798.894 uV 09:37:50 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -29.226 uVs 09:37:50 Integrated Voltage Measurement... 09:37:59 Voltage Offset Correction: v_off_ini = 1804.219 uV, v_off_fin = 1810.533 uV 09:37:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.223 uVs 09:37:59 Integrated Voltage Measurement... 09:38:08 Voltage Offset Correction: v_off_ini = 1806.217 uV, v_off_fin = 1802.151 uV 09:38:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.004 uVs 09:38:08 Integrated Voltage Measurement... 09:38:17 Voltage Offset Correction: v_off_ini = 1793.023 uV, v_off_fin = 1816.954 uV 09:38:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.298 uVs 09:38:17 Integrated Voltage Measurement... 09:38:26 Voltage Offset Correction: v_off_ini = 1792.742 uV, v_off_fin = 1798.749 uV 09:38:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.103 uVs 09:38:26 Integrated Voltage Measurement... 09:38:35 Voltage Offset Correction: v_off_ini = 1799.395 uV, v_off_fin = 1812.283 uV 09:38:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 48.441 uVs 09:38:38 I2X Average and RMS of Measurements VT = -35.549 +- 2.075 uVs I2X = 3.270 +- 0.191 uTm^2 09:38:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:38:45 Integrated Voltage Measurement... 09:38:54 Voltage Offset Correction: v_off_ini = 1798.505 uV, v_off_fin = 1801.933 uV 09:38:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -341.692 uVs 09:38:54 Integrated Voltage Measurement... 09:39:03 Voltage Offset Correction: v_off_ini = 1807.697 uV, v_off_fin = 1820.544 uV 09:39:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.994 uVs 09:39:04 Integrated Voltage Measurement... 09:39:12 Voltage Offset Correction: v_off_ini = 1806.941 uV, v_off_fin = 1807.806 uV 09:39:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -328.870 uVs 09:39:13 Integrated Voltage Measurement... 09:39:22 Voltage Offset Correction: v_off_ini = 1803.532 uV, v_off_fin = 1818.139 uV 09:39:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.116 uVs 09:39:22 Integrated Voltage Measurement... 09:39:31 Voltage Offset Correction: v_off_ini = 1813.001 uV, v_off_fin = 1833.306 uV 09:39:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.830 uVs 09:39:31 Integrated Voltage Measurement... 09:39:40 Voltage Offset Correction: v_off_ini = 1827.946 uV, v_off_fin = 1798.865 uV 09:39:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.738 uVs 09:39:42 I2Y Average and RMS of Measurements VT = -328.373 +- 6.571 uVs I2Y = -30.210 +- 0.605 uTm^2 09:39:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:39:51 Integrated Voltage Measurement... 09:40:00 Voltage Offset Correction: v_off_ini = 1814.494 uV, v_off_fin = 1794.899 uV 09:40:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -64.050 uVs 09:40:00 Integrated Voltage Measurement... 09:40:09 Voltage Offset Correction: v_off_ini = 1788.236 uV, v_off_fin = 1805.691 uV 09:40:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.132 uVs 09:40:09 Integrated Voltage Measurement... 09:40:18 Voltage Offset Correction: v_off_ini = 1808.474 uV, v_off_fin = 1799.405 uV 09:40:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.180 uVs 09:40:18 Integrated Voltage Measurement... 09:40:27 Voltage Offset Correction: v_off_ini = 1814.782 uV, v_off_fin = 1797.262 uV 09:40:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.528 uVs 09:40:27 Integrated Voltage Measurement... 09:40:36 Voltage Offset Correction: v_off_ini = 1823.509 uV, v_off_fin = 1820.283 uV 09:40:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.435 uVs 09:40:36 Integrated Voltage Measurement... 09:40:45 Voltage Offset Correction: v_off_ini = 1849.633 uV, v_off_fin = 1848.429 uV 09:40:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 33.404 uVs 09:40:49 I1X Average and RMS of Measurements VT = -43.788 +- 6.339 uVs I1X = 8.758 +- 1.268 uTm 09:40:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:40:56 Integrated Voltage Measurement... 09:41:05 Voltage Offset Correction: v_off_ini = 1815.677 uV, v_off_fin = 1805.177 uV 09:41:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -352.283 uVs 09:41:05 Integrated Voltage Measurement... 09:41:14 Voltage Offset Correction: v_off_ini = 1822.967 uV, v_off_fin = 1844.461 uV 09:41:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 314.585 uVs 09:41:14 Integrated Voltage Measurement... 09:41:23 Voltage Offset Correction: v_off_ini = 1825.619 uV, v_off_fin = 1824.360 uV 09:41:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -321.564 uVs 09:41:23 Integrated Voltage Measurement... 09:41:32 Voltage Offset Correction: v_off_ini = 1840.648 uV, v_off_fin = 1836.279 uV 09:41:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 338.775 uVs 09:41:32 Integrated Voltage Measurement... 09:41:41 Voltage Offset Correction: v_off_ini = 1837.457 uV, v_off_fin = 1812.005 uV 09:41:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -328.129 uVs 09:41:41 Integrated Voltage Measurement... 09:41:50 Voltage Offset Correction: v_off_ini = 1839.574 uV, v_off_fin = 1857.170 uV 09:41:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 319.269 uVs 09:41:54 I1Y Average and RMS of Measurements VT = -329.101 +- 4.045 uVs I1Y = -65.820 +- 0.809 uTm 09:41:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:42:02 Integrated Voltage Measurement... 09:42:11 Voltage Offset Correction: v_off_ini = 1853.990 uV, v_off_fin = 1840.229 uV 09:42:11 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -16.284 uVs 09:42:11 Integrated Voltage Measurement... 09:42:20 Voltage Offset Correction: v_off_ini = 1844.558 uV, v_off_fin = 1863.069 uV 09:42:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.013 uVs 09:42:20 Integrated Voltage Measurement... 09:42:29 Voltage Offset Correction: v_off_ini = 1859.403 uV, v_off_fin = 1819.249 uV 09:42:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -26.853 uVs 09:42:29 Integrated Voltage Measurement... 09:42:38 Voltage Offset Correction: v_off_ini = 1835.058 uV, v_off_fin = 1845.988 uV 09:42:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.079 uVs 09:42:38 Integrated Voltage Measurement... 09:42:47 Voltage Offset Correction: v_off_ini = 1855.086 uV, v_off_fin = 1833.589 uV 09:42:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.824 uVs 09:42:47 Integrated Voltage Measurement... 09:42:56 Voltage Offset Correction: v_off_ini = 1848.649 uV, v_off_fin = 1877.166 uV 09:42:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 73.701 uVs 09:42:58 I2X Average and RMS of Measurements VT = -32.792 +- 11.374 uVs I2X = 3.017 +- 1.046 uTm^2 09:43:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 09:43:06 Integrated Voltage Measurement... 09:43:15 Voltage Offset Correction: v_off_ini = 1844.859 uV, v_off_fin = 1835.337 uV 09:43:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.439 uVs 09:43:15 Integrated Voltage Measurement... 09:43:24 Voltage Offset Correction: v_off_ini = 1840.547 uV, v_off_fin = 1835.164 uV 09:43:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 334.413 uVs 09:43:24 Integrated Voltage Measurement... 09:43:33 Voltage Offset Correction: v_off_ini = 1832.247 uV, v_off_fin = 1826.733 uV 09:43:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.410 uVs 09:43:33 Integrated Voltage Measurement... 09:43:42 Voltage Offset Correction: v_off_ini = 1824.576 uV, v_off_fin = 1821.570 uV 09:43:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.113 uVs 09:43:42 Integrated Voltage Measurement... 09:43:51 Voltage Offset Correction: v_off_ini = 1838.288 uV, v_off_fin = 1844.886 uV 09:43:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -343.563 uVs 09:43:51 Integrated Voltage Measurement... 09:44:00 Voltage Offset Correction: v_off_ini = 1850.140 uV, v_off_fin = 1853.409 uV 09:44:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.313 uVs 09:44:02 I2Y Average and RMS of Measurements VT = -333.709 +- 9.567 uVs I2Y = -30.701 +- 0.880 uTm^2 09:44:07 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:44:11 Integrated Voltage Measurement... 09:44:20 Voltage Offset Correction: v_off_ini = 1872.559 uV, v_off_fin = 1869.878 uV 09:44:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.860 uVs 09:44:20 Integrated Voltage Measurement... 09:44:29 Voltage Offset Correction: v_off_ini = 1874.363 uV, v_off_fin = 1886.131 uV 09:44:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.534 uVs 09:44:29 Integrated Voltage Measurement... 09:44:38 Voltage Offset Correction: v_off_ini = 1869.887 uV, v_off_fin = 1883.186 uV 09:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 13.000 uVs 09:44:38 Integrated Voltage Measurement... 09:44:47 Voltage Offset Correction: v_off_ini = 1893.565 uV, v_off_fin = 1904.340 uV 09:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -1.487 uVs 09:44:47 Integrated Voltage Measurement... 09:44:56 Voltage Offset Correction: v_off_ini = 1897.526 uV, v_off_fin = 1891.705 uV 09:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -10.598 uVs 09:44:56 Integrated Voltage Measurement... 09:45:05 Voltage Offset Correction: v_off_ini = 1924.234 uV, v_off_fin = 1911.088 uV 09:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.653 uVs 09:45:10 I1X Average and RMS of Measurements VT = -15.360 +- 16.725 uVs I1X = 3.072 +- 3.345 uTm 09:45:12 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:45:16 Integrated Voltage Measurement... 09:45:25 Voltage Offset Correction: v_off_ini = 1909.350 uV, v_off_fin = 1919.460 uV 09:45:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -312.236 uVs 09:45:25 Integrated Voltage Measurement... 09:45:34 Voltage Offset Correction: v_off_ini = 1930.705 uV, v_off_fin = 1934.484 uV 09:45:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 338.774 uVs 09:45:34 Integrated Voltage Measurement... 09:45:43 Voltage Offset Correction: v_off_ini = 1946.964 uV, v_off_fin = 1928.185 uV 09:45:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -330.797 uVs 09:45:43 Integrated Voltage Measurement... 09:45:52 Voltage Offset Correction: v_off_ini = 1958.116 uV, v_off_fin = 1966.160 uV 09:45:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 340.737 uVs 09:45:52 Integrated Voltage Measurement... 09:46:01 Voltage Offset Correction: v_off_ini = 1970.123 uV, v_off_fin = 1968.815 uV 09:46:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -352.659 uVs 09:46:01 Integrated Voltage Measurement... 09:46:10 Voltage Offset Correction: v_off_ini = 1969.384 uV, v_off_fin = 1963.799 uV 09:46:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 343.688 uVs 09:46:14 I1Y Average and RMS of Measurements VT = -336.482 +- 9.268 uVs I1Y = -67.296 +- 1.854 uTm 09:46:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:46:22 Integrated Voltage Measurement... 09:46:31 Voltage Offset Correction: v_off_ini = 1943.457 uV, v_off_fin = 1937.915 uV 09:46:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.218 uVs 09:46:31 Integrated Voltage Measurement... 09:46:40 Voltage Offset Correction: v_off_ini = 1949.827 uV, v_off_fin = 1973.668 uV 09:46:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.933 uVs 09:46:40 Integrated Voltage Measurement... 09:46:49 Voltage Offset Correction: v_off_ini = 1956.864 uV, v_off_fin = 1941.982 uV 09:46:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.061 uVs 09:46:49 Integrated Voltage Measurement... 09:46:58 Voltage Offset Correction: v_off_ini = 1963.929 uV, v_off_fin = 1971.354 uV 09:46:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -10.670 uVs 09:46:58 Integrated Voltage Measurement... 09:47:07 Voltage Offset Correction: v_off_ini = 1956.619 uV, v_off_fin = 1931.471 uV 09:47:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.413 uVs 09:47:07 Integrated Voltage Measurement... 09:47:16 Voltage Offset Correction: v_off_ini = 1955.027 uV, v_off_fin = 1946.992 uV 09:47:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 2.168 uVs 09:47:19 I2X Average and RMS of Measurements VT = 2.762 +- 2.117 uVs I2X = -0.254 +- 0.195 uTm^2 09:47:24 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 09:47:26 Integrated Voltage Measurement... 09:47:35 Voltage Offset Correction: v_off_ini = 1918.879 uV, v_off_fin = 1930.652 uV 09:47:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.203 uVs 09:47:35 Integrated Voltage Measurement... 09:47:44 Voltage Offset Correction: v_off_ini = 1920.715 uV, v_off_fin = 1940.836 uV 09:47:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 345.379 uVs 09:47:44 Integrated Voltage Measurement... 09:47:53 Voltage Offset Correction: v_off_ini = 1968.046 uV, v_off_fin = 1965.667 uV 09:47:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.786 uVs 09:47:53 Integrated Voltage Measurement... 09:48:02 Voltage Offset Correction: v_off_ini = 1974.764 uV, v_off_fin = 1945.584 uV 09:48:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 346.184 uVs 09:48:02 Integrated Voltage Measurement... 09:48:11 Voltage Offset Correction: v_off_ini = 1932.987 uV, v_off_fin = 1926.515 uV 09:48:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -346.744 uVs 09:48:11 Integrated Voltage Measurement... 09:48:20 Voltage Offset Correction: v_off_ini = 1943.068 uV, v_off_fin = 1946.623 uV 09:48:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 362.425 uVs 09:48:23 I2Y Average and RMS of Measurements VT = -344.620 +- 8.994 uVs I2Y = -31.705 +- 0.827 uTm^2 09:48:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:48:35 Integrated Voltage Measurement... 09:48:44 Voltage Offset Correction: v_off_ini = 1951.924 uV, v_off_fin = 1974.188 uV 09:48:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -42.857 uVs 09:48:44 Integrated Voltage Measurement... 09:48:53 Voltage Offset Correction: v_off_ini = 1980.891 uV, v_off_fin = 1996.939 uV 09:48:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.984 uVs 09:48:53 Integrated Voltage Measurement... 09:49:02 Voltage Offset Correction: v_off_ini = 1986.942 uV, v_off_fin = 1979.969 uV 09:49:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.922 uVs 09:49:02 Integrated Voltage Measurement... 09:49:11 Voltage Offset Correction: v_off_ini = 2001.175 uV, v_off_fin = 1992.959 uV 09:49:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.007 uVs 09:49:11 Integrated Voltage Measurement... 09:49:20 Voltage Offset Correction: v_off_ini = 1976.862 uV, v_off_fin = 1981.932 uV 09:49:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -80.466 uVs 09:49:20 Integrated Voltage Measurement... 09:49:29 Voltage Offset Correction: v_off_ini = 1982.789 uV, v_off_fin = 2007.899 uV 09:49:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.631 uVs 09:49:33 I1X Average and RMS of Measurements VT = -59.811 +- 12.337 uVs I1X = 11.962 +- 2.467 uTm 09:49:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:49:40 Integrated Voltage Measurement... 09:49:49 Voltage Offset Correction: v_off_ini = 1996.904 uV, v_off_fin = 1962.269 uV 09:49:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -341.042 uVs 09:49:49 Integrated Voltage Measurement... 09:49:58 Voltage Offset Correction: v_off_ini = 1978.382 uV, v_off_fin = 2025.834 uV 09:49:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 360.715 uVs 09:49:58 Integrated Voltage Measurement... 09:50:07 Voltage Offset Correction: v_off_ini = 2012.339 uV, v_off_fin = 1992.998 uV 09:50:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -345.139 uVs 09:50:07 Integrated Voltage Measurement... 09:50:16 Voltage Offset Correction: v_off_ini = 2000.508 uV, v_off_fin = 2001.256 uV 09:50:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 336.375 uVs 09:50:16 Integrated Voltage Measurement... 09:50:25 Voltage Offset Correction: v_off_ini = 1995.138 uV, v_off_fin = 1981.981 uV 09:50:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -351.817 uVs 09:50:25 Integrated Voltage Measurement... 09:50:34 Voltage Offset Correction: v_off_ini = 2017.149 uV, v_off_fin = 2005.644 uV 09:50:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 345.364 uVs 09:50:38 I1Y Average and RMS of Measurements VT = -346.742 +- 4.334 uVs I1Y = -69.350 +- 0.868 uTm 09:50:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:50:43 Integrated Voltage Measurement... 09:50:52 Voltage Offset Correction: v_off_ini = 1996.777 uV, v_off_fin = 2010.111 uV 09:50:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -83.358 uVs 09:50:52 Integrated Voltage Measurement... 09:51:01 Voltage Offset Correction: v_off_ini = 2030.037 uV, v_off_fin = 2033.023 uV 09:51:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 60.495 uVs 09:51:01 Integrated Voltage Measurement... 09:51:10 Voltage Offset Correction: v_off_ini = 2017.575 uV, v_off_fin = 2011.857 uV 09:51:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.737 uVs 09:51:10 Integrated Voltage Measurement... 09:51:19 Voltage Offset Correction: v_off_ini = 2026.375 uV, v_off_fin = 2048.641 uV 09:51:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.386 uVs 09:51:19 Integrated Voltage Measurement... 09:51:28 Voltage Offset Correction: v_off_ini = 2046.400 uV, v_off_fin = 2034.097 uV 09:51:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -43.931 uVs 09:51:28 Integrated Voltage Measurement... 09:51:37 Voltage Offset Correction: v_off_ini = 2062.407 uV, v_off_fin = 2067.422 uV 09:51:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.094 uVs 09:51:39 I2X Average and RMS of Measurements VT = -53.334 +- 13.153 uVs I2X = 4.907 +- 1.210 uTm^2 09:51:42 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 09:51:45 Integrated Voltage Measurement... 09:51:54 Voltage Offset Correction: v_off_ini = 2052.812 uV, v_off_fin = 2071.302 uV 09:51:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.472 uVs 09:51:54 Integrated Voltage Measurement... 09:52:03 Voltage Offset Correction: v_off_ini = 2066.120 uV, v_off_fin = 2067.557 uV 09:52:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 344.732 uVs 09:52:03 Integrated Voltage Measurement... 09:52:12 Voltage Offset Correction: v_off_ini = 2079.998 uV, v_off_fin = 2069.539 uV 09:52:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -357.560 uVs 09:52:12 Integrated Voltage Measurement... 09:52:21 Voltage Offset Correction: v_off_ini = 2081.547 uV, v_off_fin = 2085.314 uV 09:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.385 uVs 09:52:21 Integrated Voltage Measurement... 09:52:30 Voltage Offset Correction: v_off_ini = 2084.820 uV, v_off_fin = 2071.025 uV 09:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -347.013 uVs 09:52:30 Integrated Voltage Measurement... 09:52:39 Voltage Offset Correction: v_off_ini = 2084.485 uV, v_off_fin = 2071.859 uV 09:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.248 uVs 09:52:41 I2Y Average and RMS of Measurements VT = -348.235 +- 4.223 uVs I2Y = -32.038 +- 0.389 uTm^2 09:52:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:52:49 Integrated Voltage Measurement... 09:52:58 Voltage Offset Correction: v_off_ini = 2073.788 uV, v_off_fin = 2084.972 uV 09:52:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -104.561 uVs 09:52:58 Integrated Voltage Measurement... 09:53:07 Voltage Offset Correction: v_off_ini = 2079.487 uV, v_off_fin = 2099.191 uV 09:53:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.023 uVs 09:53:07 Integrated Voltage Measurement... 09:53:16 Voltage Offset Correction: v_off_ini = 2087.102 uV, v_off_fin = 2081.928 uV 09:53:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.620 uVs 09:53:16 Integrated Voltage Measurement... 09:53:25 Voltage Offset Correction: v_off_ini = 2068.702 uV, v_off_fin = 2076.384 uV 09:53:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 56.375 uVs 09:53:25 Integrated Voltage Measurement... 09:53:34 Voltage Offset Correction: v_off_ini = 2062.037 uV, v_off_fin = 2065.951 uV 09:53:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.760 uVs 09:53:34 Integrated Voltage Measurement... 09:53:43 Voltage Offset Correction: v_off_ini = 2083.378 uV, v_off_fin = 2085.302 uV 09:53:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.819 uVs 09:53:48 I1X Average and RMS of Measurements VT = -66.693 +- 17.666 uVs I1X = 13.339 +- 3.534 uTm 09:53:50 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:53:54 Integrated Voltage Measurement... 09:54:03 Voltage Offset Correction: v_off_ini = 2077.858 uV, v_off_fin = 2080.484 uV 09:54:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -339.025 uVs 09:54:03 Integrated Voltage Measurement... 09:54:12 Voltage Offset Correction: v_off_ini = 2116.126 uV, v_off_fin = 2100.980 uV 09:54:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 341.497 uVs 09:54:12 Integrated Voltage Measurement... 09:54:21 Voltage Offset Correction: v_off_ini = 2091.493 uV, v_off_fin = 2105.537 uV 09:54:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -311.483 uVs 09:54:21 Integrated Voltage Measurement... 09:54:30 Voltage Offset Correction: v_off_ini = 2095.473 uV, v_off_fin = 2108.894 uV 09:54:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 323.460 uVs 09:54:30 Integrated Voltage Measurement... 09:54:39 Voltage Offset Correction: v_off_ini = 2088.086 uV, v_off_fin = 2092.022 uV 09:54:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -344.069 uVs 09:54:39 Integrated Voltage Measurement... 09:54:48 Voltage Offset Correction: v_off_ini = 2102.530 uV, v_off_fin = 2114.983 uV 09:54:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 329.835 uVs 09:54:53 I1Y Average and RMS of Measurements VT = -331.562 +- 10.054 uVs I1Y = -66.312 +- 2.011 uTm 09:54:55 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:54:58 Integrated Voltage Measurement... 09:55:07 Voltage Offset Correction: v_off_ini = 2095.569 uV, v_off_fin = 2104.654 uV 09:55:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.721 uVs 09:55:07 Integrated Voltage Measurement... 09:55:16 Voltage Offset Correction: v_off_ini = 2110.540 uV, v_off_fin = 2109.162 uV 09:55:16 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 34.672 uVs 09:55:16 Integrated Voltage Measurement... 09:55:25 Voltage Offset Correction: v_off_ini = 2131.410 uV, v_off_fin = 2137.693 uV 09:55:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.919 uVs 09:55:25 Integrated Voltage Measurement... 09:55:34 Voltage Offset Correction: v_off_ini = 2130.385 uV, v_off_fin = 2142.549 uV 09:55:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.345 uVs 09:55:34 Integrated Voltage Measurement... 09:55:43 Voltage Offset Correction: v_off_ini = 2129.091 uV, v_off_fin = 2107.818 uV 09:55:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.739 uVs 09:55:43 Integrated Voltage Measurement... 09:55:52 Voltage Offset Correction: v_off_ini = 2112.772 uV, v_off_fin = 2143.430 uV 09:55:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 54.631 uVs 09:55:54 I2X Average and RMS of Measurements VT = -38.671 +- 12.710 uVs I2X = 3.558 +- 1.169 uTm^2 09:55:57 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 09:55:59 Integrated Voltage Measurement... 09:56:08 Voltage Offset Correction: v_off_ini = 2101.969 uV, v_off_fin = 2113.097 uV 09:56:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.673 uVs 09:56:08 Integrated Voltage Measurement... 09:56:17 Voltage Offset Correction: v_off_ini = 2113.067 uV, v_off_fin = 2116.764 uV 09:56:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 354.428 uVs 09:56:17 Integrated Voltage Measurement... 09:56:26 Voltage Offset Correction: v_off_ini = 2105.677 uV, v_off_fin = 2092.141 uV 09:56:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.506 uVs 09:56:26 Integrated Voltage Measurement... 09:56:35 Voltage Offset Correction: v_off_ini = 2106.371 uV, v_off_fin = 2133.055 uV 09:56:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 364.813 uVs 09:56:35 Integrated Voltage Measurement... 09:56:44 Voltage Offset Correction: v_off_ini = 2113.921 uV, v_off_fin = 2097.447 uV 09:56:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.423 uVs 09:56:45 Integrated Voltage Measurement... 09:56:53 Voltage Offset Correction: v_off_ini = 2121.222 uV, v_off_fin = 2126.633 uV 09:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.798 uVs 09:56:56 I2Y Average and RMS of Measurements VT = -342.273 +- 13.141 uVs I2Y = -31.489 +- 1.209 uTm^2 09:57:00 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:57:04 Integrated Voltage Measurement... 09:57:13 Voltage Offset Correction: v_off_ini = 2120.459 uV, v_off_fin = 2124.999 uV 09:57:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -77.086 uVs 09:57:13 Integrated Voltage Measurement... 09:57:22 Voltage Offset Correction: v_off_ini = 2129.706 uV, v_off_fin = 2117.847 uV 09:57:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.200 uVs 09:57:22 Integrated Voltage Measurement... 09:57:31 Voltage Offset Correction: v_off_ini = 2096.601 uV, v_off_fin = 2120.406 uV 09:57:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.870 uVs 09:57:31 Integrated Voltage Measurement... 09:57:40 Voltage Offset Correction: v_off_ini = 2105.079 uV, v_off_fin = 2110.207 uV 09:57:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.826 uVs 09:57:40 Integrated Voltage Measurement... 09:57:49 Voltage Offset Correction: v_off_ini = 2100.998 uV, v_off_fin = 2113.138 uV 09:57:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.314 uVs 09:57:49 Integrated Voltage Measurement... 09:57:58 Voltage Offset Correction: v_off_ini = 2126.803 uV, v_off_fin = 2136.903 uV 09:57:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.848 uVs 09:58:02 I1X Average and RMS of Measurements VT = -64.191 +- 1.474 uVs I1X = 12.839 +- 0.296 uTm 09:58:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:58:09 Integrated Voltage Measurement... 09:58:18 Voltage Offset Correction: v_off_ini = 2118.424 uV, v_off_fin = 2097.110 uV 09:58:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -333.221 uVs 09:58:18 Integrated Voltage Measurement... 09:58:27 Voltage Offset Correction: v_off_ini = 2120.949 uV, v_off_fin = 2133.836 uV 09:58:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 318.564 uVs 09:58:27 Integrated Voltage Measurement... 09:58:36 Voltage Offset Correction: v_off_ini = 2133.007 uV, v_off_fin = 2135.462 uV 09:58:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -319.381 uVs 09:58:36 Integrated Voltage Measurement... 09:58:45 Voltage Offset Correction: v_off_ini = 2132.144 uV, v_off_fin = 2150.341 uV 09:58:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 342.217 uVs 09:58:45 Integrated Voltage Measurement... 09:58:54 Voltage Offset Correction: v_off_ini = 2133.614 uV, v_off_fin = 2110.704 uV 09:58:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -322.560 uVs 09:58:54 Integrated Voltage Measurement... 09:59:03 Voltage Offset Correction: v_off_ini = 2135.593 uV, v_off_fin = 2144.466 uV 09:59:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 304.229 uVs 09:59:07 I1Y Average and RMS of Measurements VT = -323.362 +- 7.327 uVs I1Y = -64.672 +- 1.465 uTm 09:59:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 09:59:12 Integrated Voltage Measurement... 09:59:21 Voltage Offset Correction: v_off_ini = 2138.786 uV, v_off_fin = 2134.641 uV 09:59:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.020 uVs 09:59:21 Integrated Voltage Measurement... 09:59:30 Voltage Offset Correction: v_off_ini = 2134.520 uV, v_off_fin = 2149.016 uV 09:59:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.110 uVs 09:59:30 Integrated Voltage Measurement... 09:59:39 Voltage Offset Correction: v_off_ini = 2133.646 uV, v_off_fin = 2122.142 uV 09:59:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.818 uVs 09:59:39 Integrated Voltage Measurement... 09:59:48 Voltage Offset Correction: v_off_ini = 2151.293 uV, v_off_fin = 2154.416 uV 09:59:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.646 uVs 09:59:48 Integrated Voltage Measurement... 09:59:57 Voltage Offset Correction: v_off_ini = 2189.802 uV, v_off_fin = 2150.758 uV 09:59:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.280 uVs 09:59:58 Integrated Voltage Measurement... 10:00:06 Voltage Offset Correction: v_off_ini = 2157.717 uV, v_off_fin = 2173.161 uV 10:00:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.807 uVs 10:00:09 I2X Average and RMS of Measurements VT = -36.614 +- 2.080 uVs I2X = 3.368 +- 0.191 uTm^2 10:00:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:00:14 Integrated Voltage Measurement... 10:00:23 Voltage Offset Correction: v_off_ini = 2158.245 uV, v_off_fin = 2149.500 uV 10:00:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.128 uVs 10:00:23 Integrated Voltage Measurement... 10:00:32 Voltage Offset Correction: v_off_ini = 2152.992 uV, v_off_fin = 2148.864 uV 10:00:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 336.679 uVs 10:00:32 Integrated Voltage Measurement... 10:00:41 Voltage Offset Correction: v_off_ini = 2159.406 uV, v_off_fin = 2151.570 uV 10:00:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.106 uVs 10:00:41 Integrated Voltage Measurement... 10:00:50 Voltage Offset Correction: v_off_ini = 2156.073 uV, v_off_fin = 2142.233 uV 10:00:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 349.204 uVs 10:00:50 Integrated Voltage Measurement... 10:00:59 Voltage Offset Correction: v_off_ini = 2146.416 uV, v_off_fin = 2162.470 uV 10:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.078 uVs 10:00:59 Integrated Voltage Measurement... 10:01:08 Voltage Offset Correction: v_off_ini = 2167.333 uV, v_off_fin = 2168.993 uV 10:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.590 uVs 10:01:11 I2Y Average and RMS of Measurements VT = -335.631 +- 4.161 uVs I2Y = -30.878 +- 0.383 uTm^2 10:01:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:01:19 Integrated Voltage Measurement... 10:01:28 Voltage Offset Correction: v_off_ini = 2161.695 uV, v_off_fin = 2182.039 uV 10:01:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -66.552 uVs 10:01:28 Integrated Voltage Measurement... 10:01:37 Voltage Offset Correction: v_off_ini = 2167.102 uV, v_off_fin = 2190.545 uV 10:01:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.707 uVs 10:01:37 Integrated Voltage Measurement... 10:01:46 Voltage Offset Correction: v_off_ini = 2183.335 uV, v_off_fin = 2183.316 uV 10:01:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -72.338 uVs 10:01:46 Integrated Voltage Measurement... 10:01:55 Voltage Offset Correction: v_off_ini = 2180.156 uV, v_off_fin = 2159.558 uV 10:01:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.113 uVs 10:01:55 Integrated Voltage Measurement... 10:02:04 Voltage Offset Correction: v_off_ini = 2163.854 uV, v_off_fin = 2155.323 uV 10:02:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.588 uVs 10:02:04 Integrated Voltage Measurement... 10:02:13 Voltage Offset Correction: v_off_ini = 2177.079 uV, v_off_fin = 2185.432 uV 10:02:13 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.545 uVs 10:02:17 I1X Average and RMS of Measurements VT = -60.640 +- 5.866 uVs I1X = 12.129 +- 1.173 uTm 10:02:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:02:24 Integrated Voltage Measurement... 10:02:33 Voltage Offset Correction: v_off_ini = 2165.928 uV, v_off_fin = 2156.543 uV 10:02:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -321.595 uVs 10:02:33 Integrated Voltage Measurement... 10:02:42 Voltage Offset Correction: v_off_ini = 2180.701 uV, v_off_fin = 2176.402 uV 10:02:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 329.168 uVs 10:02:42 Integrated Voltage Measurement... 10:02:51 Voltage Offset Correction: v_off_ini = 2185.807 uV, v_off_fin = 2161.837 uV 10:02:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -326.846 uVs 10:02:51 Integrated Voltage Measurement... 10:03:00 Voltage Offset Correction: v_off_ini = 2173.810 uV, v_off_fin = 2185.976 uV 10:03:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 322.351 uVs 10:03:00 Integrated Voltage Measurement... 10:03:09 Voltage Offset Correction: v_off_ini = 2194.414 uV, v_off_fin = 2168.682 uV 10:03:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -296.404 uVs 10:03:09 Integrated Voltage Measurement... 10:03:18 Voltage Offset Correction: v_off_ini = 2189.179 uV, v_off_fin = 2205.049 uV 10:03:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.176 uVs 10:03:22 I1Y Average and RMS of Measurements VT = -315.590 +- 13.297 uVs I1Y = -63.119 +- 2.660 uTm 10:03:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:03:27 Integrated Voltage Measurement... 10:03:36 Voltage Offset Correction: v_off_ini = 2179.180 uV, v_off_fin = 2175.520 uV 10:03:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.610 uVs 10:03:36 Integrated Voltage Measurement... 10:03:45 Voltage Offset Correction: v_off_ini = 2193.665 uV, v_off_fin = 2214.577 uV 10:03:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.454 uVs 10:03:45 Integrated Voltage Measurement... 10:03:54 Voltage Offset Correction: v_off_ini = 2180.814 uV, v_off_fin = 2186.324 uV 10:03:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.753 uVs 10:03:54 Integrated Voltage Measurement... 10:04:03 Voltage Offset Correction: v_off_ini = 2172.125 uV, v_off_fin = 2181.366 uV 10:04:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.354 uVs 10:04:03 Integrated Voltage Measurement... 10:04:12 Voltage Offset Correction: v_off_ini = 2183.037 uV, v_off_fin = 2162.328 uV 10:04:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.237 uVs 10:04:12 Integrated Voltage Measurement... 10:04:21 Voltage Offset Correction: v_off_ini = 2156.776 uV, v_off_fin = 2177.912 uV 10:04:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.061 uVs 10:04:24 I2X Average and RMS of Measurements VT = -38.411 +- 7.662 uVs I2X = 3.534 +- 0.705 uTm^2 10:04:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:04:29 Integrated Voltage Measurement... 10:04:38 Voltage Offset Correction: v_off_ini = 2170.005 uV, v_off_fin = 2184.420 uV 10:04:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.862 uVs 10:04:38 Integrated Voltage Measurement... 10:04:47 Voltage Offset Correction: v_off_ini = 2180.702 uV, v_off_fin = 2180.623 uV 10:04:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.596 uVs 10:04:47 Integrated Voltage Measurement... 10:04:56 Voltage Offset Correction: v_off_ini = 2161.165 uV, v_off_fin = 2156.618 uV 10:04:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -337.394 uVs 10:04:56 Integrated Voltage Measurement... 10:05:05 Voltage Offset Correction: v_off_ini = 2155.714 uV, v_off_fin = 2180.609 uV 10:05:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.127 uVs 10:05:05 Integrated Voltage Measurement... 10:05:14 Voltage Offset Correction: v_off_ini = 2174.874 uV, v_off_fin = 2175.646 uV 10:05:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.114 uVs 10:05:14 Integrated Voltage Measurement... 10:05:23 Voltage Offset Correction: v_off_ini = 2186.682 uV, v_off_fin = 2191.606 uV 10:05:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.923 uVs 10:05:25 I2Y Average and RMS of Measurements VT = -323.503 +- 8.100 uVs I2Y = -29.762 +- 0.745 uTm^2 10:05:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:05:33 Integrated Voltage Measurement... 10:05:42 Voltage Offset Correction: v_off_ini = 2191.556 uV, v_off_fin = 2166.363 uV 10:05:42 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -70.641 uVs 10:05:42 Integrated Voltage Measurement... 10:05:51 Voltage Offset Correction: v_off_ini = 2183.360 uV, v_off_fin = 2184.012 uV 10:05:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 65.917 uVs 10:05:51 Integrated Voltage Measurement... 10:06:00 Voltage Offset Correction: v_off_ini = 2177.391 uV, v_off_fin = 2188.159 uV 10:06:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.852 uVs 10:06:00 Integrated Voltage Measurement... 10:06:09 Voltage Offset Correction: v_off_ini = 2195.248 uV, v_off_fin = 2220.515 uV 10:06:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.442 uVs 10:06:09 Integrated Voltage Measurement... 10:06:18 Voltage Offset Correction: v_off_ini = 2208.276 uV, v_off_fin = 2214.520 uV 10:06:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.238 uVs 10:06:18 Integrated Voltage Measurement... 10:06:27 Voltage Offset Correction: v_off_ini = 2211.261 uV, v_off_fin = 2197.973 uV 10:06:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 61.077 uVs 10:06:32 I1X Average and RMS of Measurements VT = -63.695 +- 4.456 uVs I1X = 12.740 +- 0.892 uTm 10:06:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:06:38 Integrated Voltage Measurement... 10:06:47 Voltage Offset Correction: v_off_ini = 2192.971 uV, v_off_fin = 2198.419 uV 10:06:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.984 uVs 10:06:47 Integrated Voltage Measurement... 10:06:56 Voltage Offset Correction: v_off_ini = 2213.187 uV, v_off_fin = 2219.447 uV 10:06:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.063 uVs 10:06:56 Integrated Voltage Measurement... 10:07:05 Voltage Offset Correction: v_off_ini = 2177.903 uV, v_off_fin = 2185.833 uV 10:07:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.322 uVs 10:07:05 Integrated Voltage Measurement... 10:07:14 Voltage Offset Correction: v_off_ini = 2219.555 uV, v_off_fin = 2238.371 uV 10:07:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 299.579 uVs 10:07:14 Integrated Voltage Measurement... 10:07:23 Voltage Offset Correction: v_off_ini = 2233.275 uV, v_off_fin = 2217.740 uV 10:07:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.443 uVs 10:07:23 Integrated Voltage Measurement... 10:07:32 Voltage Offset Correction: v_off_ini = 2227.315 uV, v_off_fin = 2226.042 uV 10:07:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 323.121 uVs 10:07:37 I1Y Average and RMS of Measurements VT = -296.919 +- 6.718 uVs I1Y = -59.384 +- 1.344 uTm 10:07:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:07:42 Integrated Voltage Measurement... 10:07:51 Voltage Offset Correction: v_off_ini = 2215.837 uV, v_off_fin = 2194.483 uV 10:07:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -3.513 uVs 10:07:51 Integrated Voltage Measurement... 10:08:00 Voltage Offset Correction: v_off_ini = 2210.651 uV, v_off_fin = 2243.164 uV 10:08:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.201 uVs 10:08:00 Integrated Voltage Measurement... 10:08:09 Voltage Offset Correction: v_off_ini = 2240.034 uV, v_off_fin = 2228.886 uV 10:08:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -68.378 uVs 10:08:09 Integrated Voltage Measurement... 10:08:18 Voltage Offset Correction: v_off_ini = 2246.482 uV, v_off_fin = 2253.366 uV 10:08:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.791 uVs 10:08:18 Integrated Voltage Measurement... 10:08:27 Voltage Offset Correction: v_off_ini = 2229.210 uV, v_off_fin = 2219.783 uV 10:08:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.606 uVs 10:08:27 Integrated Voltage Measurement... 10:08:36 Voltage Offset Correction: v_off_ini = 2252.294 uV, v_off_fin = 2252.261 uV 10:08:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.505 uVs 10:08:38 I2X Average and RMS of Measurements VT = -34.332 +- 11.479 uVs I2X = 3.159 +- 1.056 uTm^2 10:08:41 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:08:43 Integrated Voltage Measurement... 10:08:52 Voltage Offset Correction: v_off_ini = 2245.936 uV, v_off_fin = 2248.288 uV 10:08:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.700 uVs 10:08:52 Integrated Voltage Measurement... 10:09:01 Voltage Offset Correction: v_off_ini = 2249.774 uV, v_off_fin = 2247.129 uV 10:09:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 329.877 uVs 10:09:01 Integrated Voltage Measurement... 10:09:10 Voltage Offset Correction: v_off_ini = 2255.983 uV, v_off_fin = 2249.716 uV 10:09:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.296 uVs 10:09:10 Integrated Voltage Measurement... 10:09:19 Voltage Offset Correction: v_off_ini = 2266.409 uV, v_off_fin = 2266.340 uV 10:09:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.316 uVs 10:09:19 Integrated Voltage Measurement... 10:09:28 Voltage Offset Correction: v_off_ini = 2237.151 uV, v_off_fin = 2253.919 uV 10:09:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.822 uVs 10:09:28 Integrated Voltage Measurement... 10:09:37 Voltage Offset Correction: v_off_ini = 2254.425 uV, v_off_fin = 2248.869 uV 10:09:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.650 uVs 10:09:40 I2Y Average and RMS of Measurements VT = -312.110 +- 1.668 uVs I2Y = -28.714 +- 0.153 uTm^2 10:09:57 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:10:01 Integrated Voltage Measurement... 10:10:10 Voltage Offset Correction: v_off_ini = 2231.867 uV, v_off_fin = 2229.087 uV 10:10:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -120.540 uVs 10:10:10 Integrated Voltage Measurement... 10:10:19 Voltage Offset Correction: v_off_ini = 2225.418 uV, v_off_fin = 2245.055 uV 10:10:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 100.151 uVs 10:10:19 Integrated Voltage Measurement... 10:10:28 Voltage Offset Correction: v_off_ini = 2222.989 uV, v_off_fin = 2223.985 uV 10:10:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -81.819 uVs 10:10:28 Integrated Voltage Measurement... 10:10:37 Voltage Offset Correction: v_off_ini = 2247.066 uV, v_off_fin = 2248.795 uV 10:10:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.911 uVs 10:10:37 Integrated Voltage Measurement... 10:10:46 Voltage Offset Correction: v_off_ini = 2242.099 uV, v_off_fin = 2243.255 uV 10:10:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -117.244 uVs 10:10:46 Integrated Voltage Measurement... 10:10:55 Voltage Offset Correction: v_off_ini = 2260.624 uV, v_off_fin = 2243.034 uV 10:10:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.819 uVs 10:10:59 I1X Average and RMS of Measurements VT = -103.581 +- 6.750 uVs I1X = 20.716 +- 1.350 uTm 10:11:02 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:11:06 Integrated Voltage Measurement... 10:11:15 Voltage Offset Correction: v_off_ini = 2225.009 uV, v_off_fin = 2217.140 uV 10:11:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.788 uVs 10:11:15 Integrated Voltage Measurement... 10:11:24 Voltage Offset Correction: v_off_ini = 2235.994 uV, v_off_fin = 2225.133 uV 10:11:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.846 uVs 10:11:24 Integrated Voltage Measurement... 10:11:33 Voltage Offset Correction: v_off_ini = 2214.746 uV, v_off_fin = 2204.044 uV 10:11:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -309.019 uVs 10:11:33 Integrated Voltage Measurement... 10:11:42 Voltage Offset Correction: v_off_ini = 2201.973 uV, v_off_fin = 2226.548 uV 10:11:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 303.184 uVs 10:11:42 Integrated Voltage Measurement... 10:11:51 Voltage Offset Correction: v_off_ini = 2207.979 uV, v_off_fin = 2216.068 uV 10:11:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -301.511 uVs 10:11:51 Integrated Voltage Measurement... 10:12:00 Voltage Offset Correction: v_off_ini = 2232.891 uV, v_off_fin = 2235.026 uV 10:12:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.075 uVs 10:12:04 I1Y Average and RMS of Measurements VT = -296.904 +- 8.652 uVs I1Y = -59.381 +- 1.730 uTm 10:12:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:12:12 Integrated Voltage Measurement... 10:12:21 Voltage Offset Correction: v_off_ini = 2226.222 uV, v_off_fin = 2210.871 uV 10:12:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -71.691 uVs 10:12:21 Integrated Voltage Measurement... 10:12:30 Voltage Offset Correction: v_off_ini = 2227.655 uV, v_off_fin = 2246.240 uV 10:12:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 80.436 uVs 10:12:30 Integrated Voltage Measurement... 10:12:39 Voltage Offset Correction: v_off_ini = 2249.347 uV, v_off_fin = 2229.235 uV 10:12:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -85.679 uVs 10:12:39 Integrated Voltage Measurement... 10:12:48 Voltage Offset Correction: v_off_ini = 2232.326 uV, v_off_fin = 2276.670 uV 10:12:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 103.273 uVs 10:12:48 Integrated Voltage Measurement... 10:12:57 Voltage Offset Correction: v_off_ini = 2280.689 uV, v_off_fin = 2262.247 uV 10:12:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -91.097 uVs 10:12:57 Integrated Voltage Measurement... 10:13:06 Voltage Offset Correction: v_off_ini = 2252.914 uV, v_off_fin = 2272.425 uV 10:13:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 85.193 uVs 10:13:08 I2X Average and RMS of Measurements VT = -86.228 +- 7.638 uVs I2X = 7.933 +- 0.703 uTm^2 10:13:13 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:13:16 Integrated Voltage Measurement... 10:13:25 Voltage Offset Correction: v_off_ini = 2271.846 uV, v_off_fin = 2258.870 uV 10:13:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.819 uVs 10:13:25 Integrated Voltage Measurement... 10:13:34 Voltage Offset Correction: v_off_ini = 2271.110 uV, v_off_fin = 2274.268 uV 10:13:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.505 uVs 10:13:34 Integrated Voltage Measurement... 10:13:43 Voltage Offset Correction: v_off_ini = 2286.391 uV, v_off_fin = 2277.911 uV 10:13:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -305.866 uVs 10:13:43 Integrated Voltage Measurement... 10:13:52 Voltage Offset Correction: v_off_ini = 2271.668 uV, v_off_fin = 2280.495 uV 10:13:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 333.883 uVs 10:13:52 Integrated Voltage Measurement... 10:14:01 Voltage Offset Correction: v_off_ini = 2296.099 uV, v_off_fin = 2281.519 uV 10:14:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -338.011 uVs 10:14:01 Integrated Voltage Measurement... 10:14:10 Voltage Offset Correction: v_off_ini = 2296.679 uV, v_off_fin = 2299.270 uV 10:14:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.693 uVs 10:14:12 I2Y Average and RMS of Measurements VT = -321.796 +- 8.354 uVs I2Y = -29.605 +- 0.769 uTm^2 10:14:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:14:21 Integrated Voltage Measurement... 10:14:30 Voltage Offset Correction: v_off_ini = 2274.650 uV, v_off_fin = 2281.214 uV 10:14:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.386 uVs 10:14:30 Integrated Voltage Measurement... 10:14:39 Voltage Offset Correction: v_off_ini = 2273.294 uV, v_off_fin = 2290.651 uV 10:14:39 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 89.486 uVs 10:14:39 Integrated Voltage Measurement... 10:14:48 Voltage Offset Correction: v_off_ini = 2286.554 uV, v_off_fin = 2269.743 uV 10:14:48 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.864 uVs 10:14:48 Integrated Voltage Measurement... 10:14:57 Voltage Offset Correction: v_off_ini = 2265.391 uV, v_off_fin = 2280.979 uV 10:14:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.505 uVs 10:14:57 Integrated Voltage Measurement... 10:15:06 Voltage Offset Correction: v_off_ini = 2297.637 uV, v_off_fin = 2281.902 uV 10:15:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.330 uVs 10:15:06 Integrated Voltage Measurement... 10:15:15 Voltage Offset Correction: v_off_ini = 2290.414 uV, v_off_fin = 2289.823 uV 10:15:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 136.345 uVs 10:15:19 I1X Average and RMS of Measurements VT = -97.819 +- 16.967 uVs I1X = 19.564 +- 3.393 uTm 10:15:22 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:15:26 Integrated Voltage Measurement... 10:15:35 Voltage Offset Correction: v_off_ini = 2298.533 uV, v_off_fin = 2287.445 uV 10:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -296.000 uVs 10:15:35 Integrated Voltage Measurement... 10:15:44 Voltage Offset Correction: v_off_ini = 2277.024 uV, v_off_fin = 2298.669 uV 10:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 320.281 uVs 10:15:44 Integrated Voltage Measurement... 10:15:53 Voltage Offset Correction: v_off_ini = 2307.236 uV, v_off_fin = 2300.315 uV 10:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.255 uVs 10:15:53 Integrated Voltage Measurement... 10:16:02 Voltage Offset Correction: v_off_ini = 2310.549 uV, v_off_fin = 2315.396 uV 10:16:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.088 uVs 10:16:02 Integrated Voltage Measurement... 10:16:11 Voltage Offset Correction: v_off_ini = 2286.489 uV, v_off_fin = 2284.359 uV 10:16:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -312.222 uVs 10:16:11 Integrated Voltage Measurement... 10:16:20 Voltage Offset Correction: v_off_ini = 2312.442 uV, v_off_fin = 2325.576 uV 10:16:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 306.062 uVs 10:16:24 I1Y Average and RMS of Measurements VT = -303.151 +- 7.775 uVs I1Y = -60.630 +- 1.555 uTm 10:16:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:16:32 Integrated Voltage Measurement... 10:16:41 Voltage Offset Correction: v_off_ini = 2300.243 uV, v_off_fin = 2293.796 uV 10:16:41 Integrated Voltage Measurement dXYus = -1.0001 mm, dXYds = 0.0000 mm dXY = -1.0001 mm VT = -82.286 uVs 10:16:41 Integrated Voltage Measurement... 10:16:50 Voltage Offset Correction: v_off_ini = 2311.981 uV, v_off_fin = 2324.696 uV 10:16:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.848 uVs 10:16:50 Integrated Voltage Measurement... 10:16:59 Voltage Offset Correction: v_off_ini = 2310.856 uV, v_off_fin = 2333.216 uV 10:16:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -3.078 uVs 10:16:59 Integrated Voltage Measurement... 10:17:08 Voltage Offset Correction: v_off_ini = 2325.089 uV, v_off_fin = 2338.254 uV 10:17:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 66.497 uVs 10:17:08 Integrated Voltage Measurement... 10:17:17 Voltage Offset Correction: v_off_ini = 2315.336 uV, v_off_fin = 2323.784 uV 10:17:17 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -58.936 uVs 10:17:17 Integrated Voltage Measurement... 10:17:26 Voltage Offset Correction: v_off_ini = 2313.615 uV, v_off_fin = 2347.346 uV 10:17:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.890 uVs 10:17:28 I2X Average and RMS of Measurements VT = -52.422 +- 13.207 uVs I2X = 4.823 +- 1.215 uTm^2 10:17:33 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:17:36 Integrated Voltage Measurement... 10:17:45 Voltage Offset Correction: v_off_ini = 2337.325 uV, v_off_fin = 2348.535 uV 10:17:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.023 uVs 10:17:45 Integrated Voltage Measurement... 10:17:54 Voltage Offset Correction: v_off_ini = 2323.915 uV, v_off_fin = 2325.005 uV 10:17:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.755 uVs 10:17:54 Integrated Voltage Measurement... 10:18:03 Voltage Offset Correction: v_off_ini = 2348.303 uV, v_off_fin = 2349.039 uV 10:18:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -316.791 uVs 10:18:03 Integrated Voltage Measurement... 10:18:12 Voltage Offset Correction: v_off_ini = 2323.786 uV, v_off_fin = 2332.574 uV 10:18:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.867 uVs 10:18:12 Integrated Voltage Measurement... 10:18:21 Voltage Offset Correction: v_off_ini = 2349.513 uV, v_off_fin = 2344.260 uV 10:18:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.467 uVs 10:18:21 Integrated Voltage Measurement... 10:18:30 Voltage Offset Correction: v_off_ini = 2344.104 uV, v_off_fin = 2346.927 uV 10:18:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.554 uVs 10:18:32 I2Y Average and RMS of Measurements VT = -315.243 +- 5.645 uVs I2Y = -29.002 +- 0.519 uTm^2 10:18:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:18:41 Integrated Voltage Measurement... 10:18:50 Voltage Offset Correction: v_off_ini = 2345.215 uV, v_off_fin = 2346.007 uV 10:18:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -77.997 uVs 10:18:50 Integrated Voltage Measurement... 10:18:59 Voltage Offset Correction: v_off_ini = 2363.434 uV, v_off_fin = 2355.829 uV 10:18:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.894 uVs 10:18:59 Integrated Voltage Measurement... 10:19:08 Voltage Offset Correction: v_off_ini = 2333.585 uV, v_off_fin = 2348.422 uV 10:19:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.879 uVs 10:19:08 Integrated Voltage Measurement... 10:19:17 Voltage Offset Correction: v_off_ini = 2342.034 uV, v_off_fin = 2350.061 uV 10:19:17 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.510 uVs 10:19:17 Integrated Voltage Measurement... 10:19:26 Voltage Offset Correction: v_off_ini = 2340.253 uV, v_off_fin = 2314.645 uV 10:19:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.359 uVs 10:19:26 Integrated Voltage Measurement... 10:19:35 Voltage Offset Correction: v_off_ini = 2321.540 uV, v_off_fin = 2325.877 uV 10:19:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.703 uVs 10:19:39 I1X Average and RMS of Measurements VT = -64.890 +- 15.264 uVs I1X = 12.978 +- 3.053 uTm 10:19:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:19:46 Integrated Voltage Measurement... 10:19:55 Voltage Offset Correction: v_off_ini = 2329.149 uV, v_off_fin = 2309.317 uV 10:19:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -314.512 uVs 10:19:55 Integrated Voltage Measurement... 10:20:04 Voltage Offset Correction: v_off_ini = 2301.155 uV, v_off_fin = 2318.796 uV 10:20:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 312.943 uVs 10:20:04 Integrated Voltage Measurement... 10:20:13 Voltage Offset Correction: v_off_ini = 2327.961 uV, v_off_fin = 2330.876 uV 10:20:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -300.142 uVs 10:20:13 Integrated Voltage Measurement... 10:20:22 Voltage Offset Correction: v_off_ini = 2348.808 uV, v_off_fin = 2349.445 uV 10:20:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 310.692 uVs 10:20:22 Integrated Voltage Measurement... 10:20:31 Voltage Offset Correction: v_off_ini = 2346.799 uV, v_off_fin = 2317.401 uV 10:20:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -323.898 uVs 10:20:31 Integrated Voltage Measurement... 10:20:40 Voltage Offset Correction: v_off_ini = 2322.913 uV, v_off_fin = 2332.048 uV 10:20:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 336.807 uVs 10:20:44 I1Y Average and RMS of Measurements VT = -316.499 +- 10.367 uVs I1Y = -63.300 +- 2.073 uTm 10:20:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:20:52 Integrated Voltage Measurement... 10:21:01 Voltage Offset Correction: v_off_ini = 2335.519 uV, v_off_fin = 2326.445 uV 10:21:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.022 uVs 10:21:01 Integrated Voltage Measurement... 10:21:10 Voltage Offset Correction: v_off_ini = 2363.807 uV, v_off_fin = 2371.801 uV 10:21:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.817 uVs 10:21:10 Integrated Voltage Measurement... 10:21:19 Voltage Offset Correction: v_off_ini = 2350.197 uV, v_off_fin = 2333.894 uV 10:21:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -20.386 uVs 10:21:19 Integrated Voltage Measurement... 10:21:28 Voltage Offset Correction: v_off_ini = 2359.245 uV, v_off_fin = 2361.009 uV 10:21:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.628 uVs 10:21:28 Integrated Voltage Measurement... 10:21:37 Voltage Offset Correction: v_off_ini = 2369.725 uV, v_off_fin = 2367.289 uV 10:21:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.107 uVs 10:21:37 Integrated Voltage Measurement... 10:21:46 Voltage Offset Correction: v_off_ini = 2358.541 uV, v_off_fin = 2371.463 uV 10:21:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.994 uVs 10:21:48 I2X Average and RMS of Measurements VT = -26.492 +- 8.329 uVs I2X = 2.437 +- 0.766 uTm^2 10:21:53 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:21:56 Integrated Voltage Measurement... 10:22:05 Voltage Offset Correction: v_off_ini = 2371.789 uV, v_off_fin = 2376.243 uV 10:22:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.428 uVs 10:22:05 Integrated Voltage Measurement... 10:22:14 Voltage Offset Correction: v_off_ini = 2372.766 uV, v_off_fin = 2379.992 uV 10:22:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.408 uVs 10:22:14 Integrated Voltage Measurement... 10:22:23 Voltage Offset Correction: v_off_ini = 2398.730 uV, v_off_fin = 2404.764 uV 10:22:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.123 uVs 10:22:23 Integrated Voltage Measurement... 10:22:32 Voltage Offset Correction: v_off_ini = 2401.440 uV, v_off_fin = 2411.798 uV 10:22:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 331.699 uVs 10:22:32 Integrated Voltage Measurement... 10:22:41 Voltage Offset Correction: v_off_ini = 2421.321 uV, v_off_fin = 2397.645 uV 10:22:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -379.077 uVs 10:22:41 Integrated Voltage Measurement... 10:22:50 Voltage Offset Correction: v_off_ini = 2419.395 uV, v_off_fin = 2405.374 uV 10:22:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 310.359 uVs 10:22:52 I2Y Average and RMS of Measurements VT = -334.682 +- 7.239 uVs I2Y = -30.791 +- 0.666 uTm^2 10:22:57 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:23:01 Integrated Voltage Measurement... 10:23:10 Voltage Offset Correction: v_off_ini = 2400.866 uV, v_off_fin = 2421.083 uV 10:23:10 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.817 uVs 10:23:10 Integrated Voltage Measurement... 10:23:19 Voltage Offset Correction: v_off_ini = 2429.499 uV, v_off_fin = 2429.424 uV 10:23:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 16.520 uVs 10:23:19 Integrated Voltage Measurement... 10:23:28 Voltage Offset Correction: v_off_ini = 2451.887 uV, v_off_fin = 2449.018 uV 10:23:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.149 uVs 10:23:28 Integrated Voltage Measurement... 10:23:37 Voltage Offset Correction: v_off_ini = 2451.374 uV, v_off_fin = 2452.209 uV 10:23:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.634 uVs 10:23:37 Integrated Voltage Measurement... 10:23:46 Voltage Offset Correction: v_off_ini = 2449.946 uV, v_off_fin = 2443.715 uV 10:23:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.673 uVs 10:23:46 Integrated Voltage Measurement... 10:23:55 Voltage Offset Correction: v_off_ini = 2448.841 uV, v_off_fin = 2453.789 uV 10:23:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.514 uVs 10:23:59 I1X Average and RMS of Measurements VT = -43.718 +- 15.955 uVs I1X = 8.744 +- 3.191 uTm 10:24:02 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:24:06 Integrated Voltage Measurement... 10:24:15 Voltage Offset Correction: v_off_ini = 2484.314 uV, v_off_fin = 2476.751 uV 10:24:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -301.718 uVs 10:24:15 Integrated Voltage Measurement... 10:24:24 Voltage Offset Correction: v_off_ini = 2478.761 uV, v_off_fin = 2499.200 uV 10:24:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 314.310 uVs 10:24:24 Integrated Voltage Measurement... 10:24:33 Voltage Offset Correction: v_off_ini = 2487.178 uV, v_off_fin = 2471.934 uV 10:24:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -314.567 uVs 10:24:33 Integrated Voltage Measurement... 10:24:42 Voltage Offset Correction: v_off_ini = 2485.464 uV, v_off_fin = 2501.233 uV 10:24:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 326.616 uVs 10:24:42 Integrated Voltage Measurement... 10:24:51 Voltage Offset Correction: v_off_ini = 2479.828 uV, v_off_fin = 2466.688 uV 10:24:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -320.924 uVs 10:24:51 Integrated Voltage Measurement... 10:25:00 Voltage Offset Correction: v_off_ini = 2478.635 uV, v_off_fin = 2506.034 uV 10:25:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 306.743 uVs 10:25:04 I1Y Average and RMS of Measurements VT = -314.146 +- 5.140 uVs I1Y = -62.829 +- 1.028 uTm 10:25:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:25:12 Integrated Voltage Measurement... 10:25:21 Voltage Offset Correction: v_off_ini = 2513.088 uV, v_off_fin = 2478.209 uV 10:25:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.075 uVs 10:25:21 Integrated Voltage Measurement... 10:25:30 Voltage Offset Correction: v_off_ini = 2482.112 uV, v_off_fin = 2480.143 uV 10:25:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.093 uVs 10:25:30 Integrated Voltage Measurement... 10:25:39 Voltage Offset Correction: v_off_ini = 2485.650 uV, v_off_fin = 2491.221 uV 10:25:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.931 uVs 10:25:39 Integrated Voltage Measurement... 10:25:48 Voltage Offset Correction: v_off_ini = 2486.266 uV, v_off_fin = 2481.849 uV 10:25:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.685 uVs 10:25:48 Integrated Voltage Measurement... 10:25:57 Voltage Offset Correction: v_off_ini = 2496.583 uV, v_off_fin = 2485.377 uV 10:25:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.624 uVs 10:25:57 Integrated Voltage Measurement... 10:26:06 Voltage Offset Correction: v_off_ini = 2513.586 uV, v_off_fin = 2521.480 uV 10:26:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.271 uVs 10:26:08 I2X Average and RMS of Measurements VT = -16.921 +- 5.646 uVs I2X = 1.557 +- 0.519 uTm^2 10:26:13 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 10:26:16 Integrated Voltage Measurement... 10:26:25 Voltage Offset Correction: v_off_ini = 2478.732 uV, v_off_fin = 2492.493 uV 10:26:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -348.056 uVs 10:26:25 Integrated Voltage Measurement... 10:26:34 Voltage Offset Correction: v_off_ini = 2500.890 uV, v_off_fin = 2514.719 uV 10:26:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.437 uVs 10:26:34 Integrated Voltage Measurement... 10:26:43 Voltage Offset Correction: v_off_ini = 2495.539 uV, v_off_fin = 2499.022 uV 10:26:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -335.192 uVs 10:26:43 Integrated Voltage Measurement... 10:26:52 Voltage Offset Correction: v_off_ini = 2516.009 uV, v_off_fin = 2503.603 uV 10:26:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.080 uVs 10:26:52 Integrated Voltage Measurement... 10:27:01 Voltage Offset Correction: v_off_ini = 2530.507 uV, v_off_fin = 2522.370 uV 10:27:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -336.327 uVs 10:27:01 Integrated Voltage Measurement... 10:27:10 Voltage Offset Correction: v_off_ini = 2524.101 uV, v_off_fin = 2516.514 uV 10:27:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 322.016 uVs 10:27:13 I2Y Average and RMS of Measurements VT = -333.518 +- 11.487 uVs I2Y = -30.684 +- 1.057 uTm^2 10:27:17 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:27:21 Integrated Voltage Measurement... 10:27:30 Voltage Offset Correction: v_off_ini = 2524.891 uV, v_off_fin = 2525.200 uV 10:27:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -44.551 uVs 10:27:30 Integrated Voltage Measurement... 10:27:39 Voltage Offset Correction: v_off_ini = 2534.036 uV, v_off_fin = 2541.466 uV 10:27:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 11.887 uVs 10:27:39 Integrated Voltage Measurement... 10:27:48 Voltage Offset Correction: v_off_ini = 2519.432 uV, v_off_fin = 2511.951 uV 10:27:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.842 uVs 10:27:48 Integrated Voltage Measurement... 10:27:57 Voltage Offset Correction: v_off_ini = 2519.511 uV, v_off_fin = 2519.706 uV 10:27:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.904 uVs 10:27:58 Integrated Voltage Measurement... 10:28:06 Voltage Offset Correction: v_off_ini = 2517.662 uV, v_off_fin = 2521.116 uV 10:28:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.177 uVs 10:28:07 Integrated Voltage Measurement... 10:28:15 Voltage Offset Correction: v_off_ini = 2513.812 uV, v_off_fin = 2511.968 uV 10:28:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 10.088 uVs 10:28:20 I1X Average and RMS of Measurements VT = -26.408 +- 2.160 uVs I1X = 5.282 +- 0.432 uTm 10:28:22 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:28:26 Integrated Voltage Measurement... 10:28:35 Voltage Offset Correction: v_off_ini = 2531.871 uV, v_off_fin = 2503.727 uV 10:28:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -326.858 uVs 10:28:35 Integrated Voltage Measurement... 10:28:44 Voltage Offset Correction: v_off_ini = 2513.129 uV, v_off_fin = 2520.865 uV 10:28:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 332.127 uVs 10:28:44 Integrated Voltage Measurement... 10:28:53 Voltage Offset Correction: v_off_ini = 2521.444 uV, v_off_fin = 2515.983 uV 10:28:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -319.014 uVs 10:28:53 Integrated Voltage Measurement... 10:29:02 Voltage Offset Correction: v_off_ini = 2483.036 uV, v_off_fin = 2458.724 uV 10:29:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 317.013 uVs 10:29:02 Integrated Voltage Measurement... 10:29:11 Voltage Offset Correction: v_off_ini = 2562.982 uV, v_off_fin = 2527.244 uV 10:29:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.510 uVs 10:29:11 Integrated Voltage Measurement... 10:29:20 Voltage Offset Correction: v_off_ini = 2609.015 uV, v_off_fin = 2607.824 uV 10:29:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 341.734 uVs 10:29:25 I1Y Average and RMS of Measurements VT = -321.376 +- 5.767 uVs I1Y = -64.275 +- 1.153 uTm 10:29:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:29:32 Integrated Voltage Measurement... 10:29:41 Voltage Offset Correction: v_off_ini = 2491.372 uV, v_off_fin = 2527.678 uV 10:29:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -20.065 uVs 10:29:41 Integrated Voltage Measurement... 10:29:50 Voltage Offset Correction: v_off_ini = 2622.315 uV, v_off_fin = 2537.259 uV 10:29:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -24.289 uVs 10:29:50 Integrated Voltage Measurement... 10:29:59 Voltage Offset Correction: v_off_ini = 2510.158 uV, v_off_fin = 2494.605 uV 10:29:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.101 uVs 10:29:59 Integrated Voltage Measurement... 10:30:08 Voltage Offset Correction: v_off_ini = 2535.738 uV, v_off_fin = 2518.031 uV 10:30:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -17.736 uVs 10:30:08 Integrated Voltage Measurement... 10:30:17 Voltage Offset Correction: v_off_ini = 2516.923 uV, v_off_fin = 2523.992 uV 10:30:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.725 uVs 10:30:17 Integrated Voltage Measurement... 10:30:26 Voltage Offset Correction: v_off_ini = 2521.811 uV, v_off_fin = 2531.569 uV 10:30:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.533 uVs 10:30:29 I2X Average and RMS of Measurements VT = 1.853 +- 2.787 uVs I2X = -0.170 +- 0.256 uTm^2 10:30:34 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 10:30:37 Integrated Voltage Measurement... 10:30:46 Voltage Offset Correction: v_off_ini = 2560.275 uV, v_off_fin = 2563.173 uV 10:30:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.067 uVs 10:30:46 Integrated Voltage Measurement... 10:30:55 Voltage Offset Correction: v_off_ini = 2550.543 uV, v_off_fin = 2566.593 uV 10:30:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 350.867 uVs 10:30:55 Integrated Voltage Measurement... 10:31:04 Voltage Offset Correction: v_off_ini = 2556.501 uV, v_off_fin = 2520.850 uV 10:31:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -351.557 uVs 10:31:04 Integrated Voltage Measurement... 10:31:13 Voltage Offset Correction: v_off_ini = 2541.544 uV, v_off_fin = 2486.418 uV 10:31:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 307.514 uVs 10:31:13 Integrated Voltage Measurement... 10:31:22 Voltage Offset Correction: v_off_ini = 2525.216 uV, v_off_fin = 2553.493 uV 10:31:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.400 uVs 10:31:22 Integrated Voltage Measurement... 10:31:31 Voltage Offset Correction: v_off_ini = 2541.165 uV, v_off_fin = 2542.343 uV 10:31:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.925 uVs 10:31:33 I2Y Average and RMS of Measurements VT = -325.888 +- 11.242 uVs I2Y = -29.982 +- 1.034 uTm^2 10:31:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:31:45 Integrated Voltage Measurement... 10:31:54 Voltage Offset Correction: v_off_ini = 2548.505 uV, v_off_fin = 2545.911 uV 10:31:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.003 uVs 10:31:54 Integrated Voltage Measurement... 10:32:03 Voltage Offset Correction: v_off_ini = 2541.559 uV, v_off_fin = 2559.285 uV 10:32:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.672 uVs 10:32:03 Integrated Voltage Measurement... 10:32:12 Voltage Offset Correction: v_off_ini = 2581.861 uV, v_off_fin = 2591.409 uV 10:32:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -36.565 uVs 10:32:12 Integrated Voltage Measurement... 10:32:21 Voltage Offset Correction: v_off_ini = 2601.287 uV, v_off_fin = 2597.140 uV 10:32:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.736 uVs 10:32:21 Integrated Voltage Measurement... 10:32:30 Voltage Offset Correction: v_off_ini = 2587.094 uV, v_off_fin = 2586.933 uV 10:32:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.764 uVs 10:32:30 Integrated Voltage Measurement... 10:32:39 Voltage Offset Correction: v_off_ini = 2563.233 uV, v_off_fin = 2561.457 uV 10:32:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.070 uVs 10:32:43 I1X Average and RMS of Measurements VT = -63.302 +- 8.242 uVs I1X = 12.660 +- 1.648 uTm 10:32:46 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:32:50 Integrated Voltage Measurement... 10:32:59 Voltage Offset Correction: v_off_ini = 2572.070 uV, v_off_fin = 2562.198 uV 10:32:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -328.619 uVs 10:32:59 Integrated Voltage Measurement... 10:33:08 Voltage Offset Correction: v_off_ini = 2577.499 uV, v_off_fin = 2580.631 uV 10:33:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 354.342 uVs 10:33:08 Integrated Voltage Measurement... 10:33:17 Voltage Offset Correction: v_off_ini = 2585.623 uV, v_off_fin = 2557.014 uV 10:33:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -327.834 uVs 10:33:17 Integrated Voltage Measurement... 10:33:26 Voltage Offset Correction: v_off_ini = 2591.639 uV, v_off_fin = 2603.555 uV 10:33:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 316.728 uVs 10:33:26 Integrated Voltage Measurement... 10:33:35 Voltage Offset Correction: v_off_ini = 2574.776 uV, v_off_fin = 2584.035 uV 10:33:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -339.596 uVs 10:33:35 Integrated Voltage Measurement... 10:33:44 Voltage Offset Correction: v_off_ini = 2623.697 uV, v_off_fin = 2596.898 uV 10:33:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 347.485 uVs 10:33:48 I1Y Average and RMS of Measurements VT = -335.767 +- 9.573 uVs I1Y = -67.153 +- 1.915 uTm 10:33:51 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:33:53 Integrated Voltage Measurement... 10:34:02 Voltage Offset Correction: v_off_ini = 2568.898 uV, v_off_fin = 2568.831 uV 10:34:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.925 uVs 10:34:02 Integrated Voltage Measurement... 10:34:11 Voltage Offset Correction: v_off_ini = 2584.381 uV, v_off_fin = 2591.403 uV 10:34:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.918 uVs 10:34:11 Integrated Voltage Measurement... 10:34:20 Voltage Offset Correction: v_off_ini = 2567.179 uV, v_off_fin = 2549.339 uV 10:34:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.576 uVs 10:34:20 Integrated Voltage Measurement... 10:34:29 Voltage Offset Correction: v_off_ini = 2578.886 uV, v_off_fin = 2590.275 uV 10:34:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 64.322 uVs 10:34:29 Integrated Voltage Measurement... 10:34:38 Voltage Offset Correction: v_off_ini = 2562.119 uV, v_off_fin = 2487.560 uV 10:34:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.156 uVs 10:34:39 Integrated Voltage Measurement... 10:34:47 Voltage Offset Correction: v_off_ini = 2615.375 uV, v_off_fin = 2584.598 uV 10:34:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.095 uVs 10:34:50 I2X Average and RMS of Measurements VT = -34.832 +- 0.444 uVs I2X = 3.205 +- 0.041 uTm^2 10:34:52 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 10:34:55 Integrated Voltage Measurement... 10:35:04 Voltage Offset Correction: v_off_ini = 2605.671 uV, v_off_fin = 2593.275 uV 10:35:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -362.062 uVs 10:35:04 Integrated Voltage Measurement... 10:35:13 Voltage Offset Correction: v_off_ini = 2597.690 uV, v_off_fin = 2618.488 uV 10:35:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.802 uVs 10:35:13 Integrated Voltage Measurement... 10:35:22 Voltage Offset Correction: v_off_ini = 2617.635 uV, v_off_fin = 2607.713 uV 10:35:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -353.406 uVs 10:35:22 Integrated Voltage Measurement... 10:35:31 Voltage Offset Correction: v_off_ini = 2589.559 uV, v_off_fin = 2587.982 uV 10:35:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 339.841 uVs 10:35:31 Integrated Voltage Measurement... 10:35:40 Voltage Offset Correction: v_off_ini = 2551.743 uV, v_off_fin = 2570.220 uV 10:35:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -317.744 uVs 10:35:40 Integrated Voltage Measurement... 10:35:49 Voltage Offset Correction: v_off_ini = 2559.271 uV, v_off_fin = 2577.219 uV 10:35:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 348.391 uVs 10:35:52 I2Y Average and RMS of Measurements VT = -345.708 +- 9.968 uVs I2Y = -31.805 +- 0.917 uTm^2 10:35:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:36:00 Integrated Voltage Measurement... 10:36:09 Voltage Offset Correction: v_off_ini = 2552.473 uV, v_off_fin = 2551.415 uV 10:36:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.499 uVs 10:36:09 Integrated Voltage Measurement... 10:36:18 Voltage Offset Correction: v_off_ini = 2552.642 uV, v_off_fin = 2569.512 uV 10:36:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 71.629 uVs 10:36:18 Integrated Voltage Measurement... 10:36:27 Voltage Offset Correction: v_off_ini = 2574.533 uV, v_off_fin = 2562.489 uV 10:36:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -75.765 uVs 10:36:27 Integrated Voltage Measurement... 10:36:36 Voltage Offset Correction: v_off_ini = 2554.874 uV, v_off_fin = 2555.462 uV 10:36:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 67.657 uVs 10:36:36 Integrated Voltage Measurement... 10:36:45 Voltage Offset Correction: v_off_ini = 2553.369 uV, v_off_fin = 2542.068 uV 10:36:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -49.698 uVs 10:36:45 Integrated Voltage Measurement... 10:36:54 Voltage Offset Correction: v_off_ini = 2547.769 uV, v_off_fin = 2552.332 uV 10:36:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 64.852 uVs 10:36:58 I1X Average and RMS of Measurements VT = -67.017 +- 6.890 uVs I1X = 13.404 +- 1.377 uTm 10:37:01 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:37:05 Integrated Voltage Measurement... 10:37:14 Voltage Offset Correction: v_off_ini = 2534.184 uV, v_off_fin = 2509.930 uV 10:37:14 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -338.633 uVs 10:37:14 Integrated Voltage Measurement... 10:37:23 Voltage Offset Correction: v_off_ini = 2541.669 uV, v_off_fin = 2560.685 uV 10:37:23 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 324.506 uVs 10:37:23 Integrated Voltage Measurement... 10:37:32 Voltage Offset Correction: v_off_ini = 2547.492 uV, v_off_fin = 2508.359 uV 10:37:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -314.922 uVs 10:37:32 Integrated Voltage Measurement... 10:37:41 Voltage Offset Correction: v_off_ini = 2509.972 uV, v_off_fin = 2536.216 uV 10:37:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 333.252 uVs 10:37:41 Integrated Voltage Measurement... 10:37:50 Voltage Offset Correction: v_off_ini = 2528.416 uV, v_off_fin = 2524.441 uV 10:37:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -309.963 uVs 10:37:50 Integrated Voltage Measurement... 10:37:59 Voltage Offset Correction: v_off_ini = 2529.513 uV, v_off_fin = 2535.968 uV 10:37:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 316.842 uVs 10:38:03 I1Y Average and RMS of Measurements VT = -323.020 +- 7.455 uVs I1Y = -64.604 +- 1.491 uTm 10:38:05 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:38:08 Integrated Voltage Measurement... 10:38:17 Voltage Offset Correction: v_off_ini = 2527.124 uV, v_off_fin = 2514.181 uV 10:38:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.466 uVs 10:38:17 Integrated Voltage Measurement... 10:38:26 Voltage Offset Correction: v_off_ini = 2515.985 uV, v_off_fin = 2513.521 uV 10:38:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.568 uVs 10:38:26 Integrated Voltage Measurement... 10:38:35 Voltage Offset Correction: v_off_ini = 2510.733 uV, v_off_fin = 2498.929 uV 10:38:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.493 uVs 10:38:35 Integrated Voltage Measurement... 10:38:44 Voltage Offset Correction: v_off_ini = 2519.088 uV, v_off_fin = 2511.728 uV 10:38:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.912 uVs 10:38:44 Integrated Voltage Measurement... 10:38:53 Voltage Offset Correction: v_off_ini = 2488.688 uV, v_off_fin = 2494.091 uV 10:38:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.193 uVs 10:38:53 Integrated Voltage Measurement... 10:39:02 Voltage Offset Correction: v_off_ini = 2506.099 uV, v_off_fin = 2509.067 uV 10:39:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.515 uVs 10:39:05 I2X Average and RMS of Measurements VT = -35.191 +- 1.413 uVs I2X = 3.238 +- 0.130 uTm^2 10:39:07 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 10:39:10 Integrated Voltage Measurement... 10:39:19 Voltage Offset Correction: v_off_ini = 2521.280 uV, v_off_fin = 2491.037 uV 10:39:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -334.206 uVs 10:39:19 Integrated Voltage Measurement... 10:39:28 Voltage Offset Correction: v_off_ini = 2515.562 uV, v_off_fin = 2504.462 uV 10:39:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.368 uVs 10:39:28 Integrated Voltage Measurement... 10:39:37 Voltage Offset Correction: v_off_ini = 2513.076 uV, v_off_fin = 2496.832 uV 10:39:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -332.284 uVs 10:39:37 Integrated Voltage Measurement... 10:39:46 Voltage Offset Correction: v_off_ini = 2493.380 uV, v_off_fin = 2496.074 uV 10:39:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 340.319 uVs 10:39:46 Integrated Voltage Measurement... 10:39:55 Voltage Offset Correction: v_off_ini = 2494.915 uV, v_off_fin = 2492.018 uV 10:39:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -340.415 uVs 10:39:55 Integrated Voltage Measurement... 10:40:04 Voltage Offset Correction: v_off_ini = 2451.212 uV, v_off_fin = 2521.926 uV 10:40:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -13.398 uVs 10:40:06 I2Y Average and RMS of Measurements VT = -276.365 +- 79.853 uVs I2Y = -25.426 +- 7.347 uTm^2 10:40:10 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:40:15 Integrated Voltage Measurement... 10:40:23 Voltage Offset Correction: v_off_ini = 2486.250 uV, v_off_fin = 2475.557 uV 10:40:23 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -95.964 uVs 10:40:24 Integrated Voltage Measurement... 10:40:32 Voltage Offset Correction: v_off_ini = 2480.351 uV, v_off_fin = 2490.978 uV 10:40:32 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.410 uVs 10:40:33 Integrated Voltage Measurement... 10:40:41 Voltage Offset Correction: v_off_ini = 2488.301 uV, v_off_fin = 2472.601 uV 10:40:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -64.208 uVs 10:40:42 Integrated Voltage Measurement... 10:40:50 Voltage Offset Correction: v_off_ini = 2480.330 uV, v_off_fin = 2484.563 uV 10:40:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.380 uVs 10:40:51 Integrated Voltage Measurement... 10:40:59 Voltage Offset Correction: v_off_ini = 2475.192 uV, v_off_fin = 2454.092 uV 10:41:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -86.040 uVs 10:41:00 Integrated Voltage Measurement... 10:41:08 Voltage Offset Correction: v_off_ini = 2478.254 uV, v_off_fin = 2476.752 uV 10:41:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 62.493 uVs 10:41:13 I1X Average and RMS of Measurements VT = -72.749 +- 8.799 uVs I1X = 14.551 +- 1.761 uTm 10:41:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:41:19 Integrated Voltage Measurement... 10:41:28 Voltage Offset Correction: v_off_ini = 2469.510 uV, v_off_fin = 2446.881 uV 10:41:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -310.537 uVs 10:41:28 Integrated Voltage Measurement... 10:41:37 Voltage Offset Correction: v_off_ini = 2437.793 uV, v_off_fin = 2452.800 uV 10:41:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 324.965 uVs 10:41:37 Integrated Voltage Measurement... 10:41:46 Voltage Offset Correction: v_off_ini = 2461.582 uV, v_off_fin = 2445.177 uV 10:41:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -310.085 uVs 10:41:46 Integrated Voltage Measurement... 10:41:55 Voltage Offset Correction: v_off_ini = 2437.174 uV, v_off_fin = 2449.735 uV 10:41:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 316.952 uVs 10:41:55 Integrated Voltage Measurement... 10:42:04 Voltage Offset Correction: v_off_ini = 2435.453 uV, v_off_fin = 2420.045 uV 10:42:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -302.185 uVs 10:42:04 Integrated Voltage Measurement... 10:42:13 Voltage Offset Correction: v_off_ini = 2429.980 uV, v_off_fin = 2458.936 uV 10:42:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 314.927 uVs 10:42:18 I1Y Average and RMS of Measurements VT = -313.275 +- 3.758 uVs I1Y = -62.655 +- 0.752 uTm 10:42:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:42:23 Integrated Voltage Measurement... 10:42:32 Voltage Offset Correction: v_off_ini = 2433.344 uV, v_off_fin = 2425.403 uV 10:42:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.426 uVs 10:42:32 Integrated Voltage Measurement... 10:42:41 Voltage Offset Correction: v_off_ini = 2445.844 uV, v_off_fin = 2455.717 uV 10:42:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.769 uVs 10:42:41 Integrated Voltage Measurement... 10:42:50 Voltage Offset Correction: v_off_ini = 2444.074 uV, v_off_fin = 2442.526 uV 10:42:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.473 uVs 10:42:50 Integrated Voltage Measurement... 10:42:59 Voltage Offset Correction: v_off_ini = 2460.248 uV, v_off_fin = 2472.789 uV 10:42:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 18.116 uVs 10:42:59 Integrated Voltage Measurement... 10:43:08 Voltage Offset Correction: v_off_ini = 2460.525 uV, v_off_fin = 2443.765 uV 10:43:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.547 uVs 10:43:08 Integrated Voltage Measurement... 10:43:17 Voltage Offset Correction: v_off_ini = 2462.311 uV, v_off_fin = 2472.450 uV 10:43:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.939 uVs 10:43:19 I2X Average and RMS of Measurements VT = -41.211 +- 6.805 uVs I2X = 3.791 +- 0.626 uTm^2 10:43:22 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 10:43:24 Integrated Voltage Measurement... 10:43:33 Voltage Offset Correction: v_off_ini = 2445.339 uV, v_off_fin = 2452.005 uV 10:43:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.579 uVs 10:43:33 Integrated Voltage Measurement... 10:43:42 Voltage Offset Correction: v_off_ini = 2471.175 uV, v_off_fin = 2458.620 uV 10:43:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.107 uVs 10:43:42 Integrated Voltage Measurement... 10:43:51 Voltage Offset Correction: v_off_ini = 2486.866 uV, v_off_fin = 2481.326 uV 10:43:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -306.999 uVs 10:43:51 Integrated Voltage Measurement... 10:44:00 Voltage Offset Correction: v_off_ini = 2475.698 uV, v_off_fin = 2478.955 uV 10:44:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 326.651 uVs 10:44:00 Integrated Voltage Measurement... 10:44:09 Voltage Offset Correction: v_off_ini = 2484.141 uV, v_off_fin = 2483.484 uV 10:44:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -326.433 uVs 10:44:09 Integrated Voltage Measurement... 10:44:18 Voltage Offset Correction: v_off_ini = 2489.878 uV, v_off_fin = 2496.153 uV 10:44:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.199 uVs 10:44:21 I2Y Average and RMS of Measurements VT = -314.995 +- 3.314 uVs I2Y = -28.979 +- 0.305 uTm^2 10:44:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:44:29 Integrated Voltage Measurement... 10:44:38 Voltage Offset Correction: v_off_ini = 2492.528 uV, v_off_fin = 2477.563 uV 10:44:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.258 uVs 10:44:38 Integrated Voltage Measurement... 10:44:47 Voltage Offset Correction: v_off_ini = 2476.533 uV, v_off_fin = 2490.122 uV 10:44:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.863 uVs 10:44:47 Integrated Voltage Measurement... 10:44:56 Voltage Offset Correction: v_off_ini = 2475.244 uV, v_off_fin = 2481.919 uV 10:44:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.313 uVs 10:44:56 Integrated Voltage Measurement... 10:45:05 Voltage Offset Correction: v_off_ini = 2486.055 uV, v_off_fin = 2492.967 uV 10:45:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.599 uVs 10:45:05 Integrated Voltage Measurement... 10:45:14 Voltage Offset Correction: v_off_ini = 2490.504 uV, v_off_fin = 2486.053 uV 10:45:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.936 uVs 10:45:14 Integrated Voltage Measurement... 10:45:23 Voltage Offset Correction: v_off_ini = 2482.321 uV, v_off_fin = 2495.136 uV 10:45:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 75.137 uVs 10:45:27 I1X Average and RMS of Measurements VT = -59.684 +- 8.272 uVs I1X = 11.937 +- 1.654 uTm 10:45:30 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:45:34 Integrated Voltage Measurement... 10:45:43 Voltage Offset Correction: v_off_ini = 2479.794 uV, v_off_fin = 2485.010 uV 10:45:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.690 uVs 10:45:43 Integrated Voltage Measurement... 10:45:52 Voltage Offset Correction: v_off_ini = 2490.615 uV, v_off_fin = 2503.225 uV 10:45:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.211 uVs 10:45:52 Integrated Voltage Measurement... 10:46:01 Voltage Offset Correction: v_off_ini = 2491.193 uV, v_off_fin = 2476.116 uV 10:46:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -309.184 uVs 10:46:01 Integrated Voltage Measurement... 10:46:10 Voltage Offset Correction: v_off_ini = 2486.546 uV, v_off_fin = 2503.900 uV 10:46:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 308.697 uVs 10:46:10 Integrated Voltage Measurement... 10:46:19 Voltage Offset Correction: v_off_ini = 2484.313 uV, v_off_fin = 2478.746 uV 10:46:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -309.770 uVs 10:46:19 Integrated Voltage Measurement... 10:46:28 Voltage Offset Correction: v_off_ini = 2497.516 uV, v_off_fin = 2507.959 uV 10:46:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 297.982 uVs 10:46:32 I1Y Average and RMS of Measurements VT = -302.422 +- 6.004 uVs I1Y = -60.484 +- 1.201 uTm 10:46:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:46:37 Integrated Voltage Measurement... 10:46:46 Voltage Offset Correction: v_off_ini = 2478.217 uV, v_off_fin = 2484.186 uV 10:46:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.652 uVs 10:46:46 Integrated Voltage Measurement... 10:46:55 Voltage Offset Correction: v_off_ini = 2525.660 uV, v_off_fin = 2519.299 uV 10:46:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.666 uVs 10:46:55 Integrated Voltage Measurement... 10:47:04 Voltage Offset Correction: v_off_ini = 2487.922 uV, v_off_fin = 2478.785 uV 10:47:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.498 uVs 10:47:04 Integrated Voltage Measurement... 10:47:13 Voltage Offset Correction: v_off_ini = 2509.563 uV, v_off_fin = 2501.035 uV 10:47:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.856 uVs 10:47:13 Integrated Voltage Measurement... 10:47:22 Voltage Offset Correction: v_off_ini = 2483.452 uV, v_off_fin = 2490.184 uV 10:47:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.755 uVs 10:47:22 Integrated Voltage Measurement... 10:47:31 Voltage Offset Correction: v_off_ini = 2514.664 uV, v_off_fin = 2529.102 uV 10:47:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.416 uVs 10:47:34 I2X Average and RMS of Measurements VT = -35.974 +- 3.084 uVs I2X = 3.310 +- 0.284 uTm^2 10:47:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 10:47:39 Integrated Voltage Measurement... 10:47:48 Voltage Offset Correction: v_off_ini = 2498.758 uV, v_off_fin = 2487.023 uV 10:47:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -309.933 uVs 10:47:48 Integrated Voltage Measurement... 10:47:57 Voltage Offset Correction: v_off_ini = 2488.584 uV, v_off_fin = 2497.045 uV 10:47:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.791 uVs 10:47:57 Integrated Voltage Measurement... 10:48:06 Voltage Offset Correction: v_off_ini = 2500.257 uV, v_off_fin = 2496.561 uV 10:48:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.502 uVs 10:48:06 Integrated Voltage Measurement... 10:48:15 Voltage Offset Correction: v_off_ini = 2486.291 uV, v_off_fin = 2505.652 uV 10:48:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.358 uVs 10:48:15 Integrated Voltage Measurement... 10:48:24 Voltage Offset Correction: v_off_ini = 2496.020 uV, v_off_fin = 2498.604 uV 10:48:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.838 uVs 10:48:24 Integrated Voltage Measurement... 10:48:33 Voltage Offset Correction: v_off_ini = 2523.000 uV, v_off_fin = 2522.374 uV 10:48:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.466 uVs 10:48:35 I2Y Average and RMS of Measurements VT = -303.981 +- 4.170 uVs I2Y = -27.966 +- 0.384 uTm^2 10:48:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:48:44 Integrated Voltage Measurement... 10:48:53 Voltage Offset Correction: v_off_ini = 2549.254 uV, v_off_fin = 2518.223 uV 10:48:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -74.800 uVs 10:48:53 Integrated Voltage Measurement... 10:49:02 Voltage Offset Correction: v_off_ini = 2518.014 uV, v_off_fin = 2532.610 uV 10:49:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.107 uVs 10:49:02 Integrated Voltage Measurement... 10:49:11 Voltage Offset Correction: v_off_ini = 2520.873 uV, v_off_fin = 2534.474 uV 10:49:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.225 uVs 10:49:11 Integrated Voltage Measurement... 10:49:20 Voltage Offset Correction: v_off_ini = 2552.370 uV, v_off_fin = 2563.991 uV 10:49:20 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.473 uVs 10:49:20 Integrated Voltage Measurement... 10:49:29 Voltage Offset Correction: v_off_ini = 2558.137 uV, v_off_fin = 2560.319 uV 10:49:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.796 uVs 10:49:29 Integrated Voltage Measurement... 10:49:38 Voltage Offset Correction: v_off_ini = 2551.295 uV, v_off_fin = 2543.280 uV 10:49:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.079 uVs 10:49:42 I1X Average and RMS of Measurements VT = -55.247 +- 2.659 uVs I1X = 11.050 +- 0.532 uTm 10:49:44 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:49:49 Integrated Voltage Measurement... 10:49:57 Voltage Offset Correction: v_off_ini = 2559.358 uV, v_off_fin = 2534.096 uV 10:49:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -271.235 uVs 10:49:57 Integrated Voltage Measurement... 10:50:06 Voltage Offset Correction: v_off_ini = 2537.008 uV, v_off_fin = 2562.792 uV 10:50:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.599 uVs 10:50:06 Integrated Voltage Measurement... 10:50:15 Voltage Offset Correction: v_off_ini = 2541.595 uV, v_off_fin = 2546.399 uV 10:50:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -296.892 uVs 10:50:15 Integrated Voltage Measurement... 10:50:24 Voltage Offset Correction: v_off_ini = 2557.360 uV, v_off_fin = 2556.729 uV 10:50:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.766 uVs 10:50:24 Integrated Voltage Measurement... 10:50:33 Voltage Offset Correction: v_off_ini = 2539.095 uV, v_off_fin = 2536.193 uV 10:50:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.277 uVs 10:50:33 Integrated Voltage Measurement... 10:50:42 Voltage Offset Correction: v_off_ini = 2550.730 uV, v_off_fin = 2570.987 uV 10:50:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.471 uVs 10:50:47 I1Y Average and RMS of Measurements VT = -281.373 +- 4.510 uVs I1Y = -56.276 +- 0.901 uTm 10:50:49 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:50:52 Integrated Voltage Measurement... 10:51:01 Voltage Offset Correction: v_off_ini = 2566.807 uV, v_off_fin = 2567.724 uV 10:51:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -19.617 uVs 10:51:01 Integrated Voltage Measurement... 10:51:10 Voltage Offset Correction: v_off_ini = 2555.202 uV, v_off_fin = 2559.248 uV 10:51:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 34.396 uVs 10:51:10 Integrated Voltage Measurement... 10:51:19 Voltage Offset Correction: v_off_ini = 2548.501 uV, v_off_fin = 2550.607 uV 10:51:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -30.418 uVs 10:51:19 Integrated Voltage Measurement... 10:51:28 Voltage Offset Correction: v_off_ini = 2555.749 uV, v_off_fin = 2559.380 uV 10:51:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.805 uVs 10:51:28 Integrated Voltage Measurement... 10:51:37 Voltage Offset Correction: v_off_ini = 2551.029 uV, v_off_fin = 2559.377 uV 10:51:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.304 uVs 10:51:37 Integrated Voltage Measurement... 10:51:46 Voltage Offset Correction: v_off_ini = 2536.839 uV, v_off_fin = 2530.527 uV 10:51:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.663 uVs 10:51:48 I2X Average and RMS of Measurements VT = -29.367 +- 1.707 uVs I2X = 2.702 +- 0.157 uTm^2 10:51:51 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 10:51:53 Integrated Voltage Measurement... 10:52:02 Voltage Offset Correction: v_off_ini = 2534.701 uV, v_off_fin = 2535.239 uV 10:52:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -307.386 uVs 10:52:02 Integrated Voltage Measurement... 10:52:11 Voltage Offset Correction: v_off_ini = 2533.282 uV, v_off_fin = 2551.130 uV 10:52:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.391 uVs 10:52:11 Integrated Voltage Measurement... 10:52:20 Voltage Offset Correction: v_off_ini = 2530.690 uV, v_off_fin = 2541.309 uV 10:52:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -296.002 uVs 10:52:20 Integrated Voltage Measurement... 10:52:29 Voltage Offset Correction: v_off_ini = 2566.538 uV, v_off_fin = 2570.360 uV 10:52:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 303.597 uVs 10:52:29 Integrated Voltage Measurement... 10:52:38 Voltage Offset Correction: v_off_ini = 2547.936 uV, v_off_fin = 2522.992 uV 10:52:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.562 uVs 10:52:38 Integrated Voltage Measurement... 10:52:47 Voltage Offset Correction: v_off_ini = 2538.603 uV, v_off_fin = 2532.386 uV 10:52:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.205 uVs 10:52:50 I2Y Average and RMS of Measurements VT = -304.024 +- 5.226 uVs I2Y = -27.970 +- 0.481 uTm^2 10:53:09 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:53:13 Integrated Voltage Measurement... 10:53:22 Voltage Offset Correction: v_off_ini = 2541.518 uV, v_off_fin = 2527.039 uV 10:53:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -98.258 uVs 10:53:22 Integrated Voltage Measurement... 10:53:31 Voltage Offset Correction: v_off_ini = 2527.805 uV, v_off_fin = 2545.507 uV 10:53:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 114.944 uVs 10:53:31 Integrated Voltage Measurement... 10:53:40 Voltage Offset Correction: v_off_ini = 2540.675 uV, v_off_fin = 2543.358 uV 10:53:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -111.282 uVs 10:53:40 Integrated Voltage Measurement... 10:53:49 Voltage Offset Correction: v_off_ini = 2556.294 uV, v_off_fin = 2557.997 uV 10:53:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 120.180 uVs 10:53:49 Integrated Voltage Measurement... 10:53:58 Voltage Offset Correction: v_off_ini = 2575.208 uV, v_off_fin = 2561.703 uV 10:53:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -118.257 uVs 10:53:58 Integrated Voltage Measurement... 10:54:07 Voltage Offset Correction: v_off_ini = 2553.814 uV, v_off_fin = 2562.899 uV 10:54:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 104.857 uVs 10:54:12 I1X Average and RMS of Measurements VT = -111.296 +- 3.732 uVs I1X = 22.260 +- 0.747 uTm 10:54:14 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:54:18 Integrated Voltage Measurement... 10:54:27 Voltage Offset Correction: v_off_ini = 2545.415 uV, v_off_fin = 2535.463 uV 10:54:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -282.564 uVs 10:54:27 Integrated Voltage Measurement... 10:54:36 Voltage Offset Correction: v_off_ini = 2544.522 uV, v_off_fin = 2554.490 uV 10:54:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.663 uVs 10:54:36 Integrated Voltage Measurement... 10:54:45 Voltage Offset Correction: v_off_ini = 2548.801 uV, v_off_fin = 2530.328 uV 10:54:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.006 uVs 10:54:45 Integrated Voltage Measurement... 10:54:54 Voltage Offset Correction: v_off_ini = 2551.362 uV, v_off_fin = 2571.113 uV 10:54:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.960 uVs 10:54:54 Integrated Voltage Measurement... 10:55:03 Voltage Offset Correction: v_off_ini = 2577.863 uV, v_off_fin = 2555.156 uV 10:55:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.972 uVs 10:55:03 Integrated Voltage Measurement... 10:55:12 Voltage Offset Correction: v_off_ini = 2569.995 uV, v_off_fin = 2584.496 uV 10:55:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.668 uVs 10:55:16 I1Y Average and RMS of Measurements VT = -280.639 +- 0.342 uVs I1Y = -56.129 +- 0.070 uTm 10:55:21 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:55:24 Integrated Voltage Measurement... 10:55:33 Voltage Offset Correction: v_off_ini = 2581.920 uV, v_off_fin = 2556.892 uV 10:55:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -69.723 uVs 10:55:33 Integrated Voltage Measurement... 10:55:42 Voltage Offset Correction: v_off_ini = 2585.332 uV, v_off_fin = 2569.806 uV 10:55:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 76.400 uVs 10:55:42 Integrated Voltage Measurement... 10:55:51 Voltage Offset Correction: v_off_ini = 2552.880 uV, v_off_fin = 2553.113 uV 10:55:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.576 uVs 10:55:51 Integrated Voltage Measurement... 10:56:00 Voltage Offset Correction: v_off_ini = 2576.619 uV, v_off_fin = 2594.159 uV 10:56:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.381 uVs 10:56:00 Integrated Voltage Measurement... 10:56:09 Voltage Offset Correction: v_off_ini = 2566.708 uV, v_off_fin = 2566.100 uV 10:56:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -79.824 uVs 10:56:09 Integrated Voltage Measurement... 10:56:18 Voltage Offset Correction: v_off_ini = 2561.205 uV, v_off_fin = 2553.658 uV 10:56:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 104.395 uVs 10:56:20 I2X Average and RMS of Measurements VT = -78.883 +- 9.375 uVs I2X = 7.257 +- 0.863 uTm^2 10:56:26 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 10:56:28 Integrated Voltage Measurement... 10:56:37 Voltage Offset Correction: v_off_ini = 2547.868 uV, v_off_fin = 2559.502 uV 10:56:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.278 uVs 10:56:37 Integrated Voltage Measurement... 10:56:46 Voltage Offset Correction: v_off_ini = 2556.486 uV, v_off_fin = 2554.140 uV 10:56:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 288.854 uVs 10:56:46 Integrated Voltage Measurement... 10:56:55 Voltage Offset Correction: v_off_ini = 2566.370 uV, v_off_fin = 2578.226 uV 10:56:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.967 uVs 10:56:55 Integrated Voltage Measurement... 10:57:04 Voltage Offset Correction: v_off_ini = 2598.690 uV, v_off_fin = 2583.852 uV 10:57:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 304.972 uVs 10:57:04 Integrated Voltage Measurement... 10:57:13 Voltage Offset Correction: v_off_ini = 2571.466 uV, v_off_fin = 2559.016 uV 10:57:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.351 uVs 10:57:13 Integrated Voltage Measurement... 10:57:22 Voltage Offset Correction: v_off_ini = 2554.293 uV, v_off_fin = 2559.263 uV 10:57:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 288.498 uVs 10:57:25 I2Y Average and RMS of Measurements VT = -294.153 +- 4.305 uVs I2Y = -27.063 +- 0.396 uTm^2 10:57:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:57:34 Integrated Voltage Measurement... 10:57:43 Voltage Offset Correction: v_off_ini = 2581.594 uV, v_off_fin = 2570.863 uV 10:57:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -89.572 uVs 10:57:43 Integrated Voltage Measurement... 10:57:52 Voltage Offset Correction: v_off_ini = 2579.518 uV, v_off_fin = 2575.539 uV 10:57:52 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 70.476 uVs 10:57:52 Integrated Voltage Measurement... 10:58:01 Voltage Offset Correction: v_off_ini = 2573.293 uV, v_off_fin = 2579.463 uV 10:58:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.287 uVs 10:58:01 Integrated Voltage Measurement... 10:58:10 Voltage Offset Correction: v_off_ini = 2573.643 uV, v_off_fin = 2596.032 uV 10:58:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 76.758 uVs 10:58:10 Integrated Voltage Measurement... 10:58:19 Voltage Offset Correction: v_off_ini = 2614.984 uV, v_off_fin = 2611.322 uV 10:58:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -78.959 uVs 10:58:19 Integrated Voltage Measurement... 10:58:28 Voltage Offset Correction: v_off_ini = 2613.695 uV, v_off_fin = 2611.172 uV 10:58:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 99.764 uVs 10:58:32 I1X Average and RMS of Measurements VT = -80.969 +- 6.501 uVs I1X = 16.194 +- 1.300 uTm 10:58:34 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:58:39 Integrated Voltage Measurement... 10:58:48 Voltage Offset Correction: v_off_ini = 2617.581 uV, v_off_fin = 2605.324 uV 10:58:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.467 uVs 10:58:48 Integrated Voltage Measurement... 10:58:57 Voltage Offset Correction: v_off_ini = 2594.782 uV, v_off_fin = 2614.901 uV 10:58:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.427 uVs 10:58:57 Integrated Voltage Measurement... 10:59:06 Voltage Offset Correction: v_off_ini = 2624.123 uV, v_off_fin = 2605.064 uV 10:59:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -288.296 uVs 10:59:06 Integrated Voltage Measurement... 10:59:15 Voltage Offset Correction: v_off_ini = 2617.193 uV, v_off_fin = 2632.809 uV 10:59:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.424 uVs 10:59:15 Integrated Voltage Measurement... 10:59:24 Voltage Offset Correction: v_off_ini = 2634.764 uV, v_off_fin = 2617.117 uV 10:59:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -293.571 uVs 10:59:24 Integrated Voltage Measurement... 10:59:33 Voltage Offset Correction: v_off_ini = 2628.599 uV, v_off_fin = 2643.844 uV 10:59:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.511 uVs 10:59:37 I1Y Average and RMS of Measurements VT = -285.283 +- 2.592 uVs I1Y = -57.057 +- 0.518 uTm 10:59:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 10:59:44 Integrated Voltage Measurement... 10:59:53 Voltage Offset Correction: v_off_ini = 2649.853 uV, v_off_fin = 2641.025 uV 10:59:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.062 uVs 10:59:53 Integrated Voltage Measurement... 11:00:02 Voltage Offset Correction: v_off_ini = 2633.516 uV, v_off_fin = 2636.761 uV 11:00:02 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 39.003 uVs 11:00:03 Integrated Voltage Measurement... 11:00:11 Voltage Offset Correction: v_off_ini = 2618.708 uV, v_off_fin = 2636.672 uV 11:00:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.573 uVs 11:00:12 Integrated Voltage Measurement... 11:00:20 Voltage Offset Correction: v_off_ini = 2639.136 uV, v_off_fin = 2640.220 uV 11:00:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.101 uVs 11:00:21 Integrated Voltage Measurement... 11:00:30 Voltage Offset Correction: v_off_ini = 2614.659 uV, v_off_fin = 2613.765 uV 11:00:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.571 uVs 11:00:30 Integrated Voltage Measurement... 11:00:39 Voltage Offset Correction: v_off_ini = 2635.626 uV, v_off_fin = 2642.457 uV 11:00:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 92.007 uVs 11:00:41 I2X Average and RMS of Measurements VT = -58.553 +- 10.958 uVs I2X = 5.387 +- 1.008 uTm^2 11:00:46 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:00:49 Integrated Voltage Measurement... 11:00:58 Voltage Offset Correction: v_off_ini = 2642.259 uV, v_off_fin = 2621.639 uV 11:00:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.470 uVs 11:00:58 Integrated Voltage Measurement... 11:01:07 Voltage Offset Correction: v_off_ini = 2623.298 uV, v_off_fin = 2614.882 uV 11:01:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 312.866 uVs 11:01:07 Integrated Voltage Measurement... 11:01:16 Voltage Offset Correction: v_off_ini = 2642.998 uV, v_off_fin = 2636.491 uV 11:01:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.284 uVs 11:01:16 Integrated Voltage Measurement... 11:01:25 Voltage Offset Correction: v_off_ini = 2638.854 uV, v_off_fin = 2650.040 uV 11:01:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.396 uVs 11:01:25 Integrated Voltage Measurement... 11:01:34 Voltage Offset Correction: v_off_ini = 2640.836 uV, v_off_fin = 2635.203 uV 11:01:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.974 uVs 11:01:34 Integrated Voltage Measurement... 11:01:43 Voltage Offset Correction: v_off_ini = 2643.010 uV, v_off_fin = 2636.372 uV 11:01:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.864 uVs 11:01:45 I2Y Average and RMS of Measurements VT = -306.476 +- 5.211 uVs I2Y = -28.196 +- 0.479 uTm^2 11:01:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:01:54 Integrated Voltage Measurement... 11:02:03 Voltage Offset Correction: v_off_ini = 2669.962 uV, v_off_fin = 2645.600 uV 11:02:03 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -55.780 uVs 11:02:03 Integrated Voltage Measurement... 11:02:12 Voltage Offset Correction: v_off_ini = 2657.639 uV, v_off_fin = 2664.920 uV 11:02:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.222 uVs 11:02:12 Integrated Voltage Measurement... 11:02:21 Voltage Offset Correction: v_off_ini = 2641.173 uV, v_off_fin = 2616.524 uV 11:02:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.141 uVs 11:02:21 Integrated Voltage Measurement... 11:02:30 Voltage Offset Correction: v_off_ini = 2619.453 uV, v_off_fin = 2625.966 uV 11:02:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.818 uVs 11:02:30 Integrated Voltage Measurement... 11:02:39 Voltage Offset Correction: v_off_ini = 2643.907 uV, v_off_fin = 2619.738 uV 11:02:39 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.635 uVs 11:02:39 Integrated Voltage Measurement... 11:02:48 Voltage Offset Correction: v_off_ini = 2635.744 uV, v_off_fin = 2658.216 uV 11:02:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.227 uVs 11:02:52 I1X Average and RMS of Measurements VT = -54.970 +- 1.653 uVs I1X = 10.995 +- 0.330 uTm 11:02:55 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:02:59 Integrated Voltage Measurement... 11:03:08 Voltage Offset Correction: v_off_ini = 2641.137 uV, v_off_fin = 2615.381 uV 11:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -294.399 uVs 11:03:08 Integrated Voltage Measurement... 11:03:17 Voltage Offset Correction: v_off_ini = 2659.508 uV, v_off_fin = 2653.354 uV 11:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.690 uVs 11:03:17 Integrated Voltage Measurement... 11:03:26 Voltage Offset Correction: v_off_ini = 2631.651 uV, v_off_fin = 2635.431 uV 11:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.977 uVs 11:03:26 Integrated Voltage Measurement... 11:03:35 Voltage Offset Correction: v_off_ini = 2645.254 uV, v_off_fin = 2655.210 uV 11:03:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 292.848 uVs 11:03:35 Integrated Voltage Measurement... 11:03:44 Voltage Offset Correction: v_off_ini = 2667.660 uV, v_off_fin = 2658.520 uV 11:03:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.466 uVs 11:03:44 Integrated Voltage Measurement... 11:03:53 Voltage Offset Correction: v_off_ini = 2671.537 uV, v_off_fin = 2675.761 uV 11:03:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 283.532 uVs 11:03:57 I1Y Average and RMS of Measurements VT = -293.985 +- 4.864 uVs I1Y = -58.797 +- 0.973 uTm 11:04:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:04:05 Integrated Voltage Measurement... 11:04:14 Voltage Offset Correction: v_off_ini = 2644.473 uV, v_off_fin = 2660.431 uV 11:04:14 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -33.097 uVs 11:04:14 Integrated Voltage Measurement... 11:04:23 Voltage Offset Correction: v_off_ini = 2638.717 uV, v_off_fin = 2652.916 uV 11:04:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.413 uVs 11:04:23 Integrated Voltage Measurement... 11:04:32 Voltage Offset Correction: v_off_ini = 2654.676 uV, v_off_fin = 2657.321 uV 11:04:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.076 uVs 11:04:32 Integrated Voltage Measurement... 11:04:41 Voltage Offset Correction: v_off_ini = 2666.696 uV, v_off_fin = 2674.872 uV 11:04:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.704 uVs 11:04:41 Integrated Voltage Measurement... 11:04:50 Voltage Offset Correction: v_off_ini = 2651.115 uV, v_off_fin = 2645.790 uV 11:04:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -13.045 uVs 11:04:50 Integrated Voltage Measurement... 11:04:59 Voltage Offset Correction: v_off_ini = 2671.490 uV, v_off_fin = 2683.715 uV 11:04:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.986 uVs 11:05:01 I2X Average and RMS of Measurements VT = -32.720 +- 2.632 uVs I2X = 3.010 +- 0.242 uTm^2 11:05:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:05:09 Integrated Voltage Measurement... 11:05:18 Voltage Offset Correction: v_off_ini = 2658.021 uV, v_off_fin = 2674.172 uV 11:05:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -325.711 uVs 11:05:18 Integrated Voltage Measurement... 11:05:27 Voltage Offset Correction: v_off_ini = 2687.479 uV, v_off_fin = 2673.586 uV 11:05:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.193 uVs 11:05:27 Integrated Voltage Measurement... 11:05:36 Voltage Offset Correction: v_off_ini = 2678.012 uV, v_off_fin = 2686.268 uV 11:05:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.262 uVs 11:05:36 Integrated Voltage Measurement... 11:05:45 Voltage Offset Correction: v_off_ini = 2690.001 uV, v_off_fin = 2688.883 uV 11:05:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 318.223 uVs 11:05:45 Integrated Voltage Measurement... 11:05:54 Voltage Offset Correction: v_off_ini = 2686.557 uV, v_off_fin = 2697.144 uV 11:05:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.132 uVs 11:05:54 Integrated Voltage Measurement... 11:06:03 Voltage Offset Correction: v_off_ini = 2691.119 uV, v_off_fin = 2687.810 uV 11:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.000 uVs 11:06:06 I2Y Average and RMS of Measurements VT = -321.420 +- 4.644 uVs I2Y = -29.571 +- 0.427 uTm^2 11:06:10 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:06:15 Integrated Voltage Measurement... 11:06:24 Voltage Offset Correction: v_off_ini = 2663.613 uV, v_off_fin = 2688.448 uV 11:06:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.508 uVs 11:06:24 Integrated Voltage Measurement... 11:06:33 Voltage Offset Correction: v_off_ini = 2673.213 uV, v_off_fin = 2660.115 uV 11:06:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.372 uVs 11:06:33 Integrated Voltage Measurement... 11:06:42 Voltage Offset Correction: v_off_ini = 2682.916 uV, v_off_fin = 2679.607 uV 11:06:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.290 uVs 11:06:42 Integrated Voltage Measurement... 11:06:51 Voltage Offset Correction: v_off_ini = 2672.523 uV, v_off_fin = 2668.808 uV 11:06:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.138 uVs 11:06:51 Integrated Voltage Measurement... 11:07:00 Voltage Offset Correction: v_off_ini = 2654.352 uV, v_off_fin = 2649.067 uV 11:07:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.933 uVs 11:07:00 Integrated Voltage Measurement... 11:07:09 Voltage Offset Correction: v_off_ini = 2626.142 uV, v_off_fin = 2649.644 uV 11:07:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.032 uVs 11:07:13 I1X Average and RMS of Measurements VT = -39.046 +- 8.333 uVs I1X = 7.809 +- 1.667 uTm 11:07:15 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:07:20 Integrated Voltage Measurement... 11:07:28 Voltage Offset Correction: v_off_ini = 2633.370 uV, v_off_fin = 2620.206 uV 11:07:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -305.098 uVs 11:07:29 Integrated Voltage Measurement... 11:07:37 Voltage Offset Correction: v_off_ini = 2664.411 uV, v_off_fin = 2676.236 uV 11:07:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 298.784 uVs 11:07:38 Integrated Voltage Measurement... 11:07:46 Voltage Offset Correction: v_off_ini = 2652.295 uV, v_off_fin = 2638.341 uV 11:07:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.530 uVs 11:07:47 Integrated Voltage Measurement... 11:07:55 Voltage Offset Correction: v_off_ini = 2661.910 uV, v_off_fin = 2682.834 uV 11:07:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 294.464 uVs 11:07:56 Integrated Voltage Measurement... 11:08:04 Voltage Offset Correction: v_off_ini = 2667.047 uV, v_off_fin = 2661.240 uV 11:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -308.244 uVs 11:08:05 Integrated Voltage Measurement... 11:08:13 Voltage Offset Correction: v_off_ini = 2669.526 uV, v_off_fin = 2659.441 uV 11:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 290.898 uVs 11:08:18 I1Y Average and RMS of Measurements VT = -298.336 +- 3.556 uVs I1Y = -59.667 +- 0.711 uTm 11:08:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:08:25 Integrated Voltage Measurement... 11:08:34 Voltage Offset Correction: v_off_ini = 2657.909 uV, v_off_fin = 2646.961 uV 11:08:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.550 uVs 11:08:34 Integrated Voltage Measurement... 11:08:43 Voltage Offset Correction: v_off_ini = 2655.113 uV, v_off_fin = 2651.383 uV 11:08:43 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -7.139 uVs 11:08:43 Integrated Voltage Measurement... 11:08:52 Voltage Offset Correction: v_off_ini = 2652.647 uV, v_off_fin = 2642.918 uV 11:08:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.550 uVs 11:08:52 Integrated Voltage Measurement... 11:09:01 Voltage Offset Correction: v_off_ini = 2653.030 uV, v_off_fin = 2658.212 uV 11:09:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 27.434 uVs 11:09:01 Integrated Voltage Measurement... 11:09:10 Voltage Offset Correction: v_off_ini = 2647.067 uV, v_off_fin = 2646.297 uV 11:09:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.222 uVs 11:09:11 Integrated Voltage Measurement... 11:09:19 Voltage Offset Correction: v_off_ini = 2656.383 uV, v_off_fin = 2682.234 uV 11:09:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.820 uVs 11:09:22 I2X Average and RMS of Measurements VT = -10.499 +- 8.317 uVs I2X = 0.966 +- 0.765 uTm^2 11:09:27 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:09:30 Integrated Voltage Measurement... 11:09:39 Voltage Offset Correction: v_off_ini = 2666.549 uV, v_off_fin = 2681.143 uV 11:09:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.888 uVs 11:09:39 Integrated Voltage Measurement... 11:09:48 Voltage Offset Correction: v_off_ini = 2694.340 uV, v_off_fin = 2689.564 uV 11:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.468 uVs 11:09:48 Integrated Voltage Measurement... 11:09:57 Voltage Offset Correction: v_off_ini = 2675.112 uV, v_off_fin = 2694.299 uV 11:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -313.992 uVs 11:09:57 Integrated Voltage Measurement... 11:10:06 Voltage Offset Correction: v_off_ini = 2691.074 uV, v_off_fin = 2692.878 uV 11:10:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 321.583 uVs 11:10:06 Integrated Voltage Measurement... 11:10:15 Voltage Offset Correction: v_off_ini = 2677.419 uV, v_off_fin = 2700.064 uV 11:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -312.706 uVs 11:10:15 Integrated Voltage Measurement... 11:10:24 Voltage Offset Correction: v_off_ini = 2700.004 uV, v_off_fin = 2710.901 uV 11:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 330.411 uVs 11:10:26 I2Y Average and RMS of Measurements VT = -320.508 +- 1.940 uVs I2Y = -29.487 +- 0.178 uTm^2 11:10:31 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:10:35 Integrated Voltage Measurement... 11:10:44 Voltage Offset Correction: v_off_ini = 2723.750 uV, v_off_fin = 2729.101 uV 11:10:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.501 uVs 11:10:44 Integrated Voltage Measurement... 11:10:53 Voltage Offset Correction: v_off_ini = 2738.108 uV, v_off_fin = 2758.484 uV 11:10:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -8.058 uVs 11:10:53 Integrated Voltage Measurement... 11:11:02 Voltage Offset Correction: v_off_ini = 2741.019 uV, v_off_fin = 2740.892 uV 11:11:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -20.304 uVs 11:11:02 Integrated Voltage Measurement... 11:11:11 Voltage Offset Correction: v_off_ini = 2754.013 uV, v_off_fin = 2754.763 uV 11:11:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -16.108 uVs 11:11:11 Integrated Voltage Measurement... 11:11:20 Voltage Offset Correction: v_off_ini = 2744.451 uV, v_off_fin = 2731.877 uV 11:11:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -2.290 uVs 11:11:20 Integrated Voltage Measurement... 11:11:29 Voltage Offset Correction: v_off_ini = 2740.206 uV, v_off_fin = 2734.577 uV 11:11:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 4.513 uVs 11:11:33 I1X Average and RMS of Measurements VT = -3.574 +- 1.281 uVs I1X = 0.715 +- 0.256 uTm 11:11:36 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:11:40 Integrated Voltage Measurement... 11:11:49 Voltage Offset Correction: v_off_ini = 2722.629 uV, v_off_fin = 2701.761 uV 11:11:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.549 uVs 11:11:49 Integrated Voltage Measurement... 11:11:58 Voltage Offset Correction: v_off_ini = 2710.858 uV, v_off_fin = 2727.479 uV 11:11:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 301.785 uVs 11:11:58 Integrated Voltage Measurement... 11:12:07 Voltage Offset Correction: v_off_ini = 2729.566 uV, v_off_fin = 2726.916 uV 11:12:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -325.017 uVs 11:12:07 Integrated Voltage Measurement... 11:12:16 Voltage Offset Correction: v_off_ini = 2738.286 uV, v_off_fin = 2731.212 uV 11:12:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 318.387 uVs 11:12:16 Integrated Voltage Measurement... 11:12:25 Voltage Offset Correction: v_off_ini = 2735.551 uV, v_off_fin = 2717.194 uV 11:12:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -315.424 uVs 11:12:25 Integrated Voltage Measurement... 11:12:34 Voltage Offset Correction: v_off_ini = 2727.261 uV, v_off_fin = 2727.826 uV 11:12:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 322.082 uVs 11:12:38 I1Y Average and RMS of Measurements VT = -314.874 +- 7.666 uVs I1Y = -62.975 +- 1.533 uTm 11:12:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:12:46 Integrated Voltage Measurement... 11:12:55 Voltage Offset Correction: v_off_ini = 2718.065 uV, v_off_fin = 2707.924 uV 11:12:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 17.879 uVs 11:12:55 Integrated Voltage Measurement... 11:13:04 Voltage Offset Correction: v_off_ini = 2736.835 uV, v_off_fin = 2735.858 uV 11:13:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -29.228 uVs 11:13:04 Integrated Voltage Measurement... 11:13:13 Voltage Offset Correction: v_off_ini = 2729.318 uV, v_off_fin = 2731.934 uV 11:13:13 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 32.861 uVs 11:13:13 Integrated Voltage Measurement... 11:13:22 Voltage Offset Correction: v_off_ini = 2755.287 uV, v_off_fin = 2759.360 uV 11:13:22 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -25.062 uVs 11:13:22 Integrated Voltage Measurement... 11:13:31 Voltage Offset Correction: v_off_ini = 2744.628 uV, v_off_fin = 2732.934 uV 11:13:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 14.242 uVs 11:13:31 Integrated Voltage Measurement... 11:13:40 Voltage Offset Correction: v_off_ini = 2745.068 uV, v_off_fin = 2749.436 uV 11:13:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -27.649 uVs 11:13:42 I2X Average and RMS of Measurements VT = 24.487 +- 3.338 uVs I2X = -2.253 +- 0.307 uTm^2 11:13:47 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:13:50 Integrated Voltage Measurement... 11:13:59 Voltage Offset Correction: v_off_ini = 2727.824 uV, v_off_fin = 2734.206 uV 11:13:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -308.249 uVs 11:13:59 Integrated Voltage Measurement... 11:14:08 Voltage Offset Correction: v_off_ini = 2720.263 uV, v_off_fin = 2718.311 uV 11:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.636 uVs 11:14:08 Integrated Voltage Measurement... 11:14:17 Voltage Offset Correction: v_off_ini = 2708.031 uV, v_off_fin = 2705.405 uV 11:14:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -320.336 uVs 11:14:17 Integrated Voltage Measurement... 11:14:26 Voltage Offset Correction: v_off_ini = 2701.418 uV, v_off_fin = 2713.553 uV 11:14:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 317.292 uVs 11:14:26 Integrated Voltage Measurement... 11:14:35 Voltage Offset Correction: v_off_ini = 2694.747 uV, v_off_fin = 2701.249 uV 11:14:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.894 uVs 11:14:35 Integrated Voltage Measurement... 11:14:44 Voltage Offset Correction: v_off_ini = 2698.692 uV, v_off_fin = 2712.522 uV 11:14:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 352.760 uVs 11:14:47 I2Y Average and RMS of Measurements VT = -321.528 +- 12.754 uVs I2Y = -29.581 +- 1.173 uTm^2 11:14:54 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:14:59 Integrated Voltage Measurement... 11:15:08 Voltage Offset Correction: v_off_ini = 2701.418 uV, v_off_fin = 2680.169 uV 11:15:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -47.901 uVs 11:15:08 Integrated Voltage Measurement... 11:15:17 Voltage Offset Correction: v_off_ini = 2683.460 uV, v_off_fin = 2690.780 uV 11:15:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.687 uVs 11:15:17 Integrated Voltage Measurement... 11:15:26 Voltage Offset Correction: v_off_ini = 2711.382 uV, v_off_fin = 2712.212 uV 11:15:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.201 uVs 11:15:26 Integrated Voltage Measurement... 11:15:35 Voltage Offset Correction: v_off_ini = 2686.034 uV, v_off_fin = 2694.304 uV 11:15:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.108 uVs 11:15:35 Integrated Voltage Measurement... 11:15:44 Voltage Offset Correction: v_off_ini = 2710.286 uV, v_off_fin = 2726.104 uV 11:15:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.542 uVs 11:15:44 Integrated Voltage Measurement... 11:15:53 Voltage Offset Correction: v_off_ini = 2722.381 uV, v_off_fin = 2698.851 uV 11:15:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.973 uVs 11:15:57 I1X Average and RMS of Measurements VT = -56.402 +- 4.072 uVs I1X = 11.281 +- 0.814 uTm 11:15:59 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:16:04 Integrated Voltage Measurement... 11:16:13 Voltage Offset Correction: v_off_ini = 2706.988 uV, v_off_fin = 2711.588 uV 11:16:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -315.856 uVs 11:16:13 Integrated Voltage Measurement... 11:16:22 Voltage Offset Correction: v_off_ini = 2738.500 uV, v_off_fin = 2718.330 uV 11:16:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 315.665 uVs 11:16:22 Integrated Voltage Measurement... 11:16:31 Voltage Offset Correction: v_off_ini = 2695.200 uV, v_off_fin = 2707.138 uV 11:16:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -310.020 uVs 11:16:31 Integrated Voltage Measurement... 11:16:40 Voltage Offset Correction: v_off_ini = 2741.124 uV, v_off_fin = 2757.593 uV 11:16:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 333.827 uVs 11:16:40 Integrated Voltage Measurement... 11:16:49 Voltage Offset Correction: v_off_ini = 2756.674 uV, v_off_fin = 2729.763 uV 11:16:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -322.718 uVs 11:16:49 Integrated Voltage Measurement... 11:16:58 Voltage Offset Correction: v_off_ini = 2740.574 uV, v_off_fin = 2759.906 uV 11:16:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 325.257 uVs 11:17:02 I1Y Average and RMS of Measurements VT = -320.557 +- 3.495 uVs I1Y = -64.111 +- 0.699 uTm 11:17:04 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:17:07 Integrated Voltage Measurement... 11:17:16 Voltage Offset Correction: v_off_ini = 2729.328 uV, v_off_fin = 2717.544 uV 11:17:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.453 uVs 11:17:16 Integrated Voltage Measurement... 11:17:25 Voltage Offset Correction: v_off_ini = 2731.158 uV, v_off_fin = 2719.440 uV 11:17:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 53.120 uVs 11:17:25 Integrated Voltage Measurement... 11:17:34 Voltage Offset Correction: v_off_ini = 2717.479 uV, v_off_fin = 2695.580 uV 11:17:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -57.778 uVs 11:17:34 Integrated Voltage Measurement... 11:17:43 Voltage Offset Correction: v_off_ini = 2711.068 uV, v_off_fin = 2715.801 uV 11:17:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.543 uVs 11:17:43 Integrated Voltage Measurement... 11:17:52 Voltage Offset Correction: v_off_ini = 2725.910 uV, v_off_fin = 2710.199 uV 11:17:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.439 uVs 11:17:52 Integrated Voltage Measurement... 11:18:01 Voltage Offset Correction: v_off_ini = 2730.246 uV, v_off_fin = 2745.555 uV 11:18:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.286 uVs 11:18:03 I2X Average and RMS of Measurements VT = -43.603 +- 3.439 uVs I2X = 4.012 +- 0.316 uTm^2 11:18:06 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:18:09 Integrated Voltage Measurement... 11:18:18 Voltage Offset Correction: v_off_ini = 2737.642 uV, v_off_fin = 2737.410 uV 11:18:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -318.317 uVs 11:18:18 Integrated Voltage Measurement... 11:18:27 Voltage Offset Correction: v_off_ini = 2740.069 uV, v_off_fin = 2733.745 uV 11:18:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 361.268 uVs 11:18:27 Integrated Voltage Measurement... 11:18:36 Voltage Offset Correction: v_off_ini = 2742.343 uV, v_off_fin = 2729.015 uV 11:18:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -330.950 uVs 11:18:36 Integrated Voltage Measurement... 11:18:45 Voltage Offset Correction: v_off_ini = 2733.711 uV, v_off_fin = 2730.556 uV 11:18:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 357.737 uVs 11:18:45 Integrated Voltage Measurement... 11:18:54 Voltage Offset Correction: v_off_ini = 2746.047 uV, v_off_fin = 2746.045 uV 11:18:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -345.303 uVs 11:18:54 Integrated Voltage Measurement... 11:19:03 Voltage Offset Correction: v_off_ini = 2755.138 uV, v_off_fin = 2752.315 uV 11:19:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 335.767 uVs 11:19:05 I2Y Average and RMS of Measurements VT = -341.557 +- 1.994 uVs I2Y = -31.423 +- 0.183 uTm^2 11:19:09 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:19:13 Integrated Voltage Measurement... 11:19:22 Voltage Offset Correction: v_off_ini = 2739.334 uV, v_off_fin = 2754.861 uV 11:19:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.016 uVs 11:19:22 Integrated Voltage Measurement... 11:19:31 Voltage Offset Correction: v_off_ini = 2707.915 uV, v_off_fin = 2727.979 uV 11:19:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.273 uVs 11:19:31 Integrated Voltage Measurement... 11:19:40 Voltage Offset Correction: v_off_ini = 2730.123 uV, v_off_fin = 2731.888 uV 11:19:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.769 uVs 11:19:40 Integrated Voltage Measurement... 11:19:49 Voltage Offset Correction: v_off_ini = 2757.366 uV, v_off_fin = 2764.096 uV 11:19:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.455 uVs 11:19:49 Integrated Voltage Measurement... 11:19:58 Voltage Offset Correction: v_off_ini = 2718.528 uV, v_off_fin = 2741.458 uV 11:19:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -10.331 uVs 11:19:58 Integrated Voltage Measurement... 11:20:07 Voltage Offset Correction: v_off_ini = 2760.421 uV, v_off_fin = 2753.219 uV 11:20:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.098 uVs 11:20:12 I1X Average and RMS of Measurements VT = -45.990 +- 15.701 uVs I1X = 9.198 +- 3.140 uTm 11:20:14 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:20:18 Integrated Voltage Measurement... 11:20:27 Voltage Offset Correction: v_off_ini = 2755.558 uV, v_off_fin = 2735.530 uV 11:20:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -297.175 uVs 11:20:27 Integrated Voltage Measurement... 11:20:36 Voltage Offset Correction: v_off_ini = 2751.402 uV, v_off_fin = 2760.051 uV 11:20:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.564 uVs 11:20:36 Integrated Voltage Measurement... 11:20:45 Voltage Offset Correction: v_off_ini = 2742.896 uV, v_off_fin = 2747.745 uV 11:20:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -327.890 uVs 11:20:45 Integrated Voltage Measurement... 11:20:54 Voltage Offset Correction: v_off_ini = 2754.171 uV, v_off_fin = 2770.666 uV 11:20:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 303.357 uVs 11:20:54 Integrated Voltage Measurement... 11:21:03 Voltage Offset Correction: v_off_ini = 2770.680 uV, v_off_fin = 2749.183 uV 11:21:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -306.508 uVs 11:21:03 Integrated Voltage Measurement... 11:21:12 Voltage Offset Correction: v_off_ini = 2763.985 uV, v_off_fin = 2781.363 uV 11:21:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 300.464 uVs 11:21:17 I1Y Average and RMS of Measurements VT = -305.160 +- 7.949 uVs I1Y = -61.032 +- 1.590 uTm 11:21:19 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:21:22 Integrated Voltage Measurement... 11:21:31 Voltage Offset Correction: v_off_ini = 2761.216 uV, v_off_fin = 2776.095 uV 11:21:31 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.750 uVs 11:21:31 Integrated Voltage Measurement... 11:21:40 Voltage Offset Correction: v_off_ini = 2783.602 uV, v_off_fin = 2790.303 uV 11:21:40 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.962 uVs 11:21:40 Integrated Voltage Measurement... 11:21:49 Voltage Offset Correction: v_off_ini = 2784.259 uV, v_off_fin = 2770.093 uV 11:21:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.164 uVs 11:21:49 Integrated Voltage Measurement... 11:21:58 Voltage Offset Correction: v_off_ini = 2783.704 uV, v_off_fin = 2792.260 uV 11:21:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.964 uVs 11:21:58 Integrated Voltage Measurement... 11:22:07 Voltage Offset Correction: v_off_ini = 2802.574 uV, v_off_fin = 2782.634 uV 11:22:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -52.622 uVs 11:22:07 Integrated Voltage Measurement... 11:22:16 Voltage Offset Correction: v_off_ini = 2798.355 uV, v_off_fin = 2816.625 uV 11:22:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.689 uVs 11:22:18 I2X Average and RMS of Measurements VT = -36.692 +- 12.722 uVs I2X = 3.376 +- 1.170 uTm^2 11:22:21 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 11:22:23 Integrated Voltage Measurement... 11:22:32 Voltage Offset Correction: v_off_ini = 2800.450 uV, v_off_fin = 2789.319 uV 11:22:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.913 uVs 11:22:32 Integrated Voltage Measurement... 11:22:41 Voltage Offset Correction: v_off_ini = 2790.236 uV, v_off_fin = 2788.033 uV 11:22:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 332.430 uVs 11:22:41 Integrated Voltage Measurement... 11:22:50 Voltage Offset Correction: v_off_ini = 2790.029 uV, v_off_fin = 2794.035 uV 11:22:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -319.425 uVs 11:22:50 Integrated Voltage Measurement... 11:22:59 Voltage Offset Correction: v_off_ini = 2791.172 uV, v_off_fin = 2790.932 uV 11:22:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 319.796 uVs 11:22:59 Integrated Voltage Measurement... 11:23:08 Voltage Offset Correction: v_off_ini = 2798.405 uV, v_off_fin = 2797.893 uV 11:23:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -342.726 uVs 11:23:08 Integrated Voltage Measurement... 11:23:17 Voltage Offset Correction: v_off_ini = 2799.387 uV, v_off_fin = 2794.509 uV 11:23:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.742 uVs 11:23:20 I2Y Average and RMS of Measurements VT = -325.505 +- 5.711 uVs I2Y = -29.946 +- 0.525 uTm^2 11:23:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:23:28 Integrated Voltage Measurement... 11:23:37 Voltage Offset Correction: v_off_ini = 2802.603 uV, v_off_fin = 2791.381 uV 11:23:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -92.129 uVs 11:23:37 Integrated Voltage Measurement... 11:23:46 Voltage Offset Correction: v_off_ini = 2760.065 uV, v_off_fin = 2785.230 uV 11:23:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.035 uVs 11:23:46 Integrated Voltage Measurement... 11:23:55 Voltage Offset Correction: v_off_ini = 2801.994 uV, v_off_fin = 2790.951 uV 11:23:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -68.519 uVs 11:23:55 Integrated Voltage Measurement... 11:24:04 Voltage Offset Correction: v_off_ini = 2802.115 uV, v_off_fin = 2820.636 uV 11:24:04 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 36.623 uVs 11:24:04 Integrated Voltage Measurement... 11:24:13 Voltage Offset Correction: v_off_ini = 2805.827 uV, v_off_fin = 2795.307 uV 11:24:13 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -47.684 uVs 11:24:13 Integrated Voltage Measurement... 11:24:22 Voltage Offset Correction: v_off_ini = 2808.876 uV, v_off_fin = 2808.984 uV 11:24:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 60.931 uVs 11:24:26 I1X Average and RMS of Measurements VT = -60.487 +- 9.992 uVs I1X = 12.098 +- 1.998 uTm 11:24:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:24:33 Integrated Voltage Measurement... 11:24:42 Voltage Offset Correction: v_off_ini = 2815.906 uV, v_off_fin = 2807.493 uV 11:24:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.735 uVs 11:24:42 Integrated Voltage Measurement... 11:24:51 Voltage Offset Correction: v_off_ini = 2813.167 uV, v_off_fin = 2824.289 uV 11:24:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.079 uVs 11:24:51 Integrated Voltage Measurement... 11:25:00 Voltage Offset Correction: v_off_ini = 2794.774 uV, v_off_fin = 2773.238 uV 11:25:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -284.994 uVs 11:25:00 Integrated Voltage Measurement... 11:25:09 Voltage Offset Correction: v_off_ini = 2804.061 uV, v_off_fin = 2805.672 uV 11:25:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 296.542 uVs 11:25:09 Integrated Voltage Measurement... 11:25:18 Voltage Offset Correction: v_off_ini = 2809.974 uV, v_off_fin = 2806.955 uV 11:25:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -316.220 uVs 11:25:18 Integrated Voltage Measurement... 11:25:27 Voltage Offset Correction: v_off_ini = 2830.951 uV, v_off_fin = 2826.675 uV 11:25:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 286.832 uVs 11:25:31 I1Y Average and RMS of Measurements VT = -293.734 +- 5.562 uVs I1Y = -58.747 +- 1.112 uTm 11:25:34 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:25:36 Integrated Voltage Measurement... 11:25:45 Voltage Offset Correction: v_off_ini = 2820.304 uV, v_off_fin = 2806.012 uV 11:25:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -4.151 uVs 11:25:45 Integrated Voltage Measurement... 11:25:54 Voltage Offset Correction: v_off_ini = 2834.292 uV, v_off_fin = 2840.439 uV 11:25:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.693 uVs 11:25:54 Integrated Voltage Measurement... 11:26:03 Voltage Offset Correction: v_off_ini = 2823.903 uV, v_off_fin = 2811.026 uV 11:26:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.714 uVs 11:26:03 Integrated Voltage Measurement... 11:26:12 Voltage Offset Correction: v_off_ini = 2805.378 uV, v_off_fin = 2818.147 uV 11:26:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.724 uVs 11:26:12 Integrated Voltage Measurement... 11:26:21 Voltage Offset Correction: v_off_ini = 2823.384 uV, v_off_fin = 2801.491 uV 11:26:21 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -11.810 uVs 11:26:21 Integrated Voltage Measurement... 11:26:30 Voltage Offset Correction: v_off_ini = 2847.477 uV, v_off_fin = 2844.990 uV 11:26:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.854 uVs 11:26:33 I2X Average and RMS of Measurements VT = -26.658 +- 1.950 uVs I2X = 2.453 +- 0.179 uTm^2 11:26:35 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:26:38 Integrated Voltage Measurement... 11:26:47 Voltage Offset Correction: v_off_ini = 2838.817 uV, v_off_fin = 2836.996 uV 11:26:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -339.747 uVs 11:26:47 Integrated Voltage Measurement... 11:26:56 Voltage Offset Correction: v_off_ini = 2835.564 uV, v_off_fin = 2843.481 uV 11:26:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.803 uVs 11:26:56 Integrated Voltage Measurement... 11:27:05 Voltage Offset Correction: v_off_ini = 2856.212 uV, v_off_fin = 2848.165 uV 11:27:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -324.618 uVs 11:27:05 Integrated Voltage Measurement... 11:27:14 Voltage Offset Correction: v_off_ini = 2832.632 uV, v_off_fin = 2834.225 uV 11:27:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.392 uVs 11:27:14 Integrated Voltage Measurement... 11:27:23 Voltage Offset Correction: v_off_ini = 2852.541 uV, v_off_fin = 2857.890 uV 11:27:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -321.366 uVs 11:27:23 Integrated Voltage Measurement... 11:27:32 Voltage Offset Correction: v_off_ini = 2852.920 uV, v_off_fin = 2852.380 uV 11:27:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 327.160 uVs 11:27:34 I2Y Average and RMS of Measurements VT = -322.181 +- 4.831 uVs I2Y = -29.641 +- 0.444 uTm^2 11:27:38 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:27:43 Integrated Voltage Measurement... 11:27:52 Voltage Offset Correction: v_off_ini = 2843.907 uV, v_off_fin = 2844.293 uV 11:27:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -76.538 uVs 11:27:52 Integrated Voltage Measurement... 11:28:01 Voltage Offset Correction: v_off_ini = 2842.092 uV, v_off_fin = 2831.888 uV 11:28:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.266 uVs 11:28:01 Integrated Voltage Measurement... 11:28:10 Voltage Offset Correction: v_off_ini = 2801.135 uV, v_off_fin = 2800.457 uV 11:28:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -22.891 uVs 11:28:10 Integrated Voltage Measurement... 11:28:19 Voltage Offset Correction: v_off_ini = 2808.720 uV, v_off_fin = 2813.938 uV 11:28:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 61.395 uVs 11:28:19 Integrated Voltage Measurement... 11:28:28 Voltage Offset Correction: v_off_ini = 2811.801 uV, v_off_fin = 2807.370 uV 11:28:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -29.259 uVs 11:28:28 Integrated Voltage Measurement... 11:28:37 Voltage Offset Correction: v_off_ini = 2822.518 uV, v_off_fin = 2822.653 uV 11:28:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.230 uVs 11:28:41 I1X Average and RMS of Measurements VT = -48.263 +- 8.939 uVs I1X = 9.654 +- 1.789 uTm 11:28:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:28:48 Integrated Voltage Measurement... 11:28:57 Voltage Offset Correction: v_off_ini = 2854.901 uV, v_off_fin = 2831.675 uV 11:28:57 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -261.316 uVs 11:28:57 Integrated Voltage Measurement... 11:29:06 Voltage Offset Correction: v_off_ini = 2851.974 uV, v_off_fin = 2859.162 uV 11:29:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 293.608 uVs 11:29:06 Integrated Voltage Measurement... 11:29:15 Voltage Offset Correction: v_off_ini = 2843.813 uV, v_off_fin = 2843.165 uV 11:29:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.241 uVs 11:29:15 Integrated Voltage Measurement... 11:29:24 Voltage Offset Correction: v_off_ini = 2865.365 uV, v_off_fin = 2877.595 uV 11:29:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 295.516 uVs 11:29:24 Integrated Voltage Measurement... 11:29:33 Voltage Offset Correction: v_off_ini = 2847.566 uV, v_off_fin = 2844.703 uV 11:29:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.215 uVs 11:29:33 Integrated Voltage Measurement... 11:29:42 Voltage Offset Correction: v_off_ini = 2880.625 uV, v_off_fin = 2882.920 uV 11:29:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.754 uVs 11:29:46 I1Y Average and RMS of Measurements VT = -284.942 +- 6.533 uVs I1Y = -56.990 +- 1.305 uTm 11:29:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:29:51 Integrated Voltage Measurement... 11:30:00 Voltage Offset Correction: v_off_ini = 2846.927 uV, v_off_fin = 2839.105 uV 11:30:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.786 uVs 11:30:00 Integrated Voltage Measurement... 11:30:09 Voltage Offset Correction: v_off_ini = 2848.726 uV, v_off_fin = 2864.788 uV 11:30:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.224 uVs 11:30:09 Integrated Voltage Measurement... 11:30:18 Voltage Offset Correction: v_off_ini = 2841.281 uV, v_off_fin = 2842.997 uV 11:30:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.922 uVs 11:30:18 Integrated Voltage Measurement... 11:30:27 Voltage Offset Correction: v_off_ini = 2859.572 uV, v_off_fin = 2864.762 uV 11:30:27 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 29.776 uVs 11:30:27 Integrated Voltage Measurement... 11:30:36 Voltage Offset Correction: v_off_ini = 2862.091 uV, v_off_fin = 2840.366 uV 11:30:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.096 uVs 11:30:36 Integrated Voltage Measurement... 11:30:45 Voltage Offset Correction: v_off_ini = 2854.550 uV, v_off_fin = 2884.965 uV 11:30:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.333 uVs 11:30:48 I2X Average and RMS of Measurements VT = -26.412 +- 7.558 uVs I2X = 2.430 +- 0.695 uTm^2 11:30:50 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 11:30:53 Integrated Voltage Measurement... 11:31:02 Voltage Offset Correction: v_off_ini = 2879.016 uV, v_off_fin = 2873.377 uV 11:31:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.255 uVs 11:31:02 Integrated Voltage Measurement... 11:31:11 Voltage Offset Correction: v_off_ini = 2880.352 uV, v_off_fin = 2900.033 uV 11:31:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 298.064 uVs 11:31:11 Integrated Voltage Measurement... 11:31:20 Voltage Offset Correction: v_off_ini = 2895.238 uV, v_off_fin = 2863.078 uV 11:31:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.614 uVs 11:31:20 Integrated Voltage Measurement... 11:31:29 Voltage Offset Correction: v_off_ini = 2885.685 uV, v_off_fin = 2889.179 uV 11:31:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 314.991 uVs 11:31:29 Integrated Voltage Measurement... 11:31:38 Voltage Offset Correction: v_off_ini = 2890.000 uV, v_off_fin = 2888.618 uV 11:31:38 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -261.318 uVs 11:31:38 Integrated Voltage Measurement... 11:31:47 Voltage Offset Correction: v_off_ini = 2893.430 uV, v_off_fin = 2881.639 uV 11:31:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.973 uVs 11:31:49 I2Y Average and RMS of Measurements VT = -288.703 +- 9.978 uVs I2Y = -26.561 +- 0.918 uTm^2 11:31:53 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:31:57 Integrated Voltage Measurement... 11:32:06 Voltage Offset Correction: v_off_ini = 2897.751 uV, v_off_fin = 2867.979 uV 11:32:06 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -62.298 uVs 11:32:06 Integrated Voltage Measurement... 11:32:15 Voltage Offset Correction: v_off_ini = 2862.441 uV, v_off_fin = 2862.898 uV 11:32:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 48.907 uVs 11:32:16 Integrated Voltage Measurement... 11:32:24 Voltage Offset Correction: v_off_ini = 2847.413 uV, v_off_fin = 2833.501 uV 11:32:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.245 uVs 11:32:25 Integrated Voltage Measurement... 11:32:33 Voltage Offset Correction: v_off_ini = 2849.743 uV, v_off_fin = 2866.834 uV 11:32:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 43.574 uVs 11:32:34 Integrated Voltage Measurement... 11:32:42 Voltage Offset Correction: v_off_ini = 2856.738 uV, v_off_fin = 2856.299 uV 11:32:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.393 uVs 11:32:43 Integrated Voltage Measurement... 11:32:52 Voltage Offset Correction: v_off_ini = 2859.569 uV, v_off_fin = 2869.211 uV 11:32:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.236 uVs 11:32:56 I1X Average and RMS of Measurements VT = -45.609 +- 8.505 uVs I1X = 9.123 +- 1.702 uTm 11:32:58 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:33:02 Integrated Voltage Measurement... 11:33:11 Voltage Offset Correction: v_off_ini = 2852.950 uV, v_off_fin = 2823.843 uV 11:33:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.615 uVs 11:33:11 Integrated Voltage Measurement... 11:33:20 Voltage Offset Correction: v_off_ini = 2843.560 uV, v_off_fin = 2860.758 uV 11:33:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.672 uVs 11:33:20 Integrated Voltage Measurement... 11:33:29 Voltage Offset Correction: v_off_ini = 2840.592 uV, v_off_fin = 2826.494 uV 11:33:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.459 uVs 11:33:29 Integrated Voltage Measurement... 11:33:38 Voltage Offset Correction: v_off_ini = 2856.844 uV, v_off_fin = 2869.006 uV 11:33:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.274 uVs 11:33:38 Integrated Voltage Measurement... 11:33:47 Voltage Offset Correction: v_off_ini = 2850.566 uV, v_off_fin = 2854.050 uV 11:33:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -283.626 uVs 11:33:47 Integrated Voltage Measurement... 11:33:56 Voltage Offset Correction: v_off_ini = 2885.371 uV, v_off_fin = 2895.414 uV 11:33:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 285.569 uVs 11:34:01 I1Y Average and RMS of Measurements VT = -276.536 +- 5.708 uVs I1Y = -55.307 +- 1.142 uTm 11:34:03 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:34:06 Integrated Voltage Measurement... 11:34:15 Voltage Offset Correction: v_off_ini = 2867.898 uV, v_off_fin = 2849.632 uV 11:34:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.315 uVs 11:34:15 Integrated Voltage Measurement... 11:34:24 Voltage Offset Correction: v_off_ini = 2873.582 uV, v_off_fin = 2872.719 uV 11:34:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.776 uVs 11:34:24 Integrated Voltage Measurement... 11:34:33 Voltage Offset Correction: v_off_ini = 2868.488 uV, v_off_fin = 2859.701 uV 11:34:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.653 uVs 11:34:33 Integrated Voltage Measurement... 11:34:42 Voltage Offset Correction: v_off_ini = 2868.996 uV, v_off_fin = 2870.912 uV 11:34:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.408 uVs 11:34:42 Integrated Voltage Measurement... 11:34:51 Voltage Offset Correction: v_off_ini = 2877.342 uV, v_off_fin = 2855.002 uV 11:34:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.098 uVs 11:34:51 Integrated Voltage Measurement... 11:35:00 Voltage Offset Correction: v_off_ini = 2873.666 uV, v_off_fin = 2888.675 uV 11:35:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.556 uVs 11:35:02 I2X Average and RMS of Measurements VT = -18.634 +- 13.527 uVs I2X = 1.714 +- 1.244 uTm^2 11:35:05 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 11:35:07 Integrated Voltage Measurement... 11:35:16 Voltage Offset Correction: v_off_ini = 2872.946 uV, v_off_fin = 2862.569 uV 11:35:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -293.525 uVs 11:35:16 Integrated Voltage Measurement... 11:35:25 Voltage Offset Correction: v_off_ini = 2877.129 uV, v_off_fin = 2867.390 uV 11:35:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.087 uVs 11:35:25 Integrated Voltage Measurement... 11:35:34 Voltage Offset Correction: v_off_ini = 2868.090 uV, v_off_fin = 2853.581 uV 11:35:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -294.783 uVs 11:35:34 Integrated Voltage Measurement... 11:35:43 Voltage Offset Correction: v_off_ini = 2849.637 uV, v_off_fin = 2860.026 uV 11:35:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.614 uVs 11:35:43 Integrated Voltage Measurement... 11:35:52 Voltage Offset Correction: v_off_ini = 2846.451 uV, v_off_fin = 2852.093 uV 11:35:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -277.901 uVs 11:35:52 Integrated Voltage Measurement... 11:36:01 Voltage Offset Correction: v_off_ini = 2867.648 uV, v_off_fin = 2877.232 uV 11:36:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 297.764 uVs 11:36:04 I2Y Average and RMS of Measurements VT = -295.446 +- 5.511 uVs I2Y = -27.181 +- 0.507 uTm^2 11:36:28 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:36:32 Integrated Voltage Measurement... 11:36:41 Voltage Offset Correction: v_off_ini = 2890.108 uV, v_off_fin = 2867.550 uV 11:36:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -106.858 uVs 11:36:41 Integrated Voltage Measurement... 11:36:50 Voltage Offset Correction: v_off_ini = 2858.038 uV, v_off_fin = 2854.285 uV 11:36:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 109.318 uVs 11:36:50 Integrated Voltage Measurement... 11:36:59 Voltage Offset Correction: v_off_ini = 2870.028 uV, v_off_fin = 2874.370 uV 11:36:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -88.609 uVs 11:36:59 Integrated Voltage Measurement... 11:37:08 Voltage Offset Correction: v_off_ini = 2899.224 uV, v_off_fin = 2893.640 uV 11:37:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 115.977 uVs 11:37:08 Integrated Voltage Measurement... 11:37:17 Voltage Offset Correction: v_off_ini = 2868.598 uV, v_off_fin = 2878.838 uV 11:37:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.727 uVs 11:37:17 Integrated Voltage Measurement... 11:37:26 Voltage Offset Correction: v_off_ini = 2898.404 uV, v_off_fin = 2898.372 uV 11:37:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.140 uVs 11:37:30 I1X Average and RMS of Measurements VT = -94.771 +- 14.924 uVs I1X = 18.954 +- 2.985 uTm 11:37:33 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:37:37 Integrated Voltage Measurement... 11:37:46 Voltage Offset Correction: v_off_ini = 2871.350 uV, v_off_fin = 2867.936 uV 11:37:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.672 uVs 11:37:46 Integrated Voltage Measurement... 11:37:55 Voltage Offset Correction: v_off_ini = 2884.512 uV, v_off_fin = 2888.191 uV 11:37:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.743 uVs 11:37:55 Integrated Voltage Measurement... 11:38:04 Voltage Offset Correction: v_off_ini = 2892.633 uV, v_off_fin = 2867.159 uV 11:38:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -253.739 uVs 11:38:04 Integrated Voltage Measurement... 11:38:13 Voltage Offset Correction: v_off_ini = 2881.965 uV, v_off_fin = 2894.404 uV 11:38:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.473 uVs 11:38:13 Integrated Voltage Measurement... 11:38:22 Voltage Offset Correction: v_off_ini = 2874.410 uV, v_off_fin = 2867.526 uV 11:38:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -263.810 uVs 11:38:22 Integrated Voltage Measurement... 11:38:31 Voltage Offset Correction: v_off_ini = 2882.368 uV, v_off_fin = 2902.018 uV 11:38:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.657 uVs 11:38:35 I1Y Average and RMS of Measurements VT = -260.349 +- 3.116 uVs I1Y = -52.070 +- 0.623 uTm 11:38:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:38:43 Integrated Voltage Measurement... 11:38:52 Voltage Offset Correction: v_off_ini = 2880.280 uV, v_off_fin = 2888.262 uV 11:38:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -59.729 uVs 11:38:52 Integrated Voltage Measurement... 11:39:01 Voltage Offset Correction: v_off_ini = 2895.363 uV, v_off_fin = 2911.392 uV 11:39:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 83.534 uVs 11:39:01 Integrated Voltage Measurement... 11:39:10 Voltage Offset Correction: v_off_ini = 2894.100 uV, v_off_fin = 2885.948 uV 11:39:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -88.847 uVs 11:39:10 Integrated Voltage Measurement... 11:39:19 Voltage Offset Correction: v_off_ini = 2902.250 uV, v_off_fin = 2918.990 uV 11:39:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.103 uVs 11:39:19 Integrated Voltage Measurement... 11:39:28 Voltage Offset Correction: v_off_ini = 2899.163 uV, v_off_fin = 2902.950 uV 11:39:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -86.988 uVs 11:39:28 Integrated Voltage Measurement... 11:39:37 Voltage Offset Correction: v_off_ini = 2892.758 uV, v_off_fin = 2893.817 uV 11:39:37 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 46.866 uVs 11:39:39 I2X Average and RMS of Measurements VT = -71.511 +- 3.695 uVs I2X = 6.579 +- 0.340 uTm^2 11:39:44 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 11:39:47 Integrated Voltage Measurement... 11:39:56 Voltage Offset Correction: v_off_ini = 2904.144 uV, v_off_fin = 2901.406 uV 11:39:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -301.901 uVs 11:39:56 Integrated Voltage Measurement... 11:40:05 Voltage Offset Correction: v_off_ini = 2910.536 uV, v_off_fin = 2893.849 uV 11:40:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.476 uVs 11:40:05 Integrated Voltage Measurement... 11:40:14 Voltage Offset Correction: v_off_ini = 2900.062 uV, v_off_fin = 2913.715 uV 11:40:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -256.942 uVs 11:40:14 Integrated Voltage Measurement... 11:40:23 Voltage Offset Correction: v_off_ini = 2927.025 uV, v_off_fin = 2926.281 uV 11:40:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.577 uVs 11:40:23 Integrated Voltage Measurement... 11:40:32 Voltage Offset Correction: v_off_ini = 2904.443 uV, v_off_fin = 2899.617 uV 11:40:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.664 uVs 11:40:32 Integrated Voltage Measurement... 11:40:41 Voltage Offset Correction: v_off_ini = 2902.704 uV, v_off_fin = 2914.089 uV 11:40:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.983 uVs 11:40:43 I2Y Average and RMS of Measurements VT = -279.924 +- 12.481 uVs I2Y = -25.753 +- 1.148 uTm^2 11:40:48 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:40:52 Integrated Voltage Measurement... 11:41:01 Voltage Offset Correction: v_off_ini = 2914.989 uV, v_off_fin = 2915.220 uV 11:41:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.983 uVs 11:41:01 Integrated Voltage Measurement... 11:41:10 Voltage Offset Correction: v_off_ini = 2908.168 uV, v_off_fin = 2918.413 uV 11:41:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 79.673 uVs 11:41:10 Integrated Voltage Measurement... 11:41:19 Voltage Offset Correction: v_off_ini = 2907.694 uV, v_off_fin = 2884.245 uV 11:41:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.682 uVs 11:41:19 Integrated Voltage Measurement... 11:41:28 Voltage Offset Correction: v_off_ini = 2885.017 uV, v_off_fin = 2916.656 uV 11:41:28 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.942 uVs 11:41:28 Integrated Voltage Measurement... 11:41:37 Voltage Offset Correction: v_off_ini = 2897.893 uV, v_off_fin = 2896.314 uV 11:41:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -70.273 uVs 11:41:37 Integrated Voltage Measurement... 11:41:46 Voltage Offset Correction: v_off_ini = 2904.262 uV, v_off_fin = 2909.815 uV 11:41:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 69.750 uVs 11:41:51 I1X Average and RMS of Measurements VT = -68.384 +- 1.170 uVs I1X = 13.677 +- 0.234 uTm 11:41:53 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:41:57 Integrated Voltage Measurement... 11:42:06 Voltage Offset Correction: v_off_ini = 2919.962 uV, v_off_fin = 2916.080 uV 11:42:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.827 uVs 11:42:06 Integrated Voltage Measurement... 11:42:15 Voltage Offset Correction: v_off_ini = 2930.875 uV, v_off_fin = 2934.731 uV 11:42:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.697 uVs 11:42:15 Integrated Voltage Measurement... 11:42:24 Voltage Offset Correction: v_off_ini = 2911.793 uV, v_off_fin = 2905.924 uV 11:42:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.698 uVs 11:42:24 Integrated Voltage Measurement... 11:42:33 Voltage Offset Correction: v_off_ini = 2910.755 uV, v_off_fin = 2930.886 uV 11:42:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.016 uVs 11:42:33 Integrated Voltage Measurement... 11:42:42 Voltage Offset Correction: v_off_ini = 2932.442 uV, v_off_fin = 2910.072 uV 11:42:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.331 uVs 11:42:42 Integrated Voltage Measurement... 11:42:51 Voltage Offset Correction: v_off_ini = 2921.666 uV, v_off_fin = 2950.129 uV 11:42:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.968 uVs 11:42:55 I1Y Average and RMS of Measurements VT = -264.590 +- 6.259 uVs I1Y = -52.918 +- 1.252 uTm 11:43:01 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:43:03 Integrated Voltage Measurement... 11:43:12 Voltage Offset Correction: v_off_ini = 2945.957 uV, v_off_fin = 2937.950 uV 11:43:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -51.704 uVs 11:43:12 Integrated Voltage Measurement... 11:43:21 Voltage Offset Correction: v_off_ini = 2934.470 uV, v_off_fin = 2968.173 uV 11:43:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.842 uVs 11:43:21 Integrated Voltage Measurement... 11:43:30 Voltage Offset Correction: v_off_ini = 2940.689 uV, v_off_fin = 2948.047 uV 11:43:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -62.202 uVs 11:43:30 Integrated Voltage Measurement... 11:43:39 Voltage Offset Correction: v_off_ini = 2949.700 uV, v_off_fin = 2955.642 uV 11:43:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.637 uVs 11:43:39 Integrated Voltage Measurement... 11:43:48 Voltage Offset Correction: v_off_ini = 2938.419 uV, v_off_fin = 2958.786 uV 11:43:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.037 uVs 11:43:48 Integrated Voltage Measurement... 11:43:57 Voltage Offset Correction: v_off_ini = 2969.033 uV, v_off_fin = 2964.961 uV 11:43:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 57.165 uVs 11:44:00 I2X Average and RMS of Measurements VT = -44.098 +- 9.405 uVs I2X = 4.057 +- 0.865 uTm^2 11:44:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 11:44:07 Integrated Voltage Measurement... 11:44:16 Voltage Offset Correction: v_off_ini = 2953.916 uV, v_off_fin = 2958.701 uV 11:44:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -302.779 uVs 11:44:16 Integrated Voltage Measurement... 11:44:25 Voltage Offset Correction: v_off_ini = 2959.078 uV, v_off_fin = 2963.073 uV 11:44:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 284.992 uVs 11:44:25 Integrated Voltage Measurement... 11:44:34 Voltage Offset Correction: v_off_ini = 2969.225 uV, v_off_fin = 2964.339 uV 11:44:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -257.331 uVs 11:44:34 Integrated Voltage Measurement... 11:44:43 Voltage Offset Correction: v_off_ini = 2965.598 uV, v_off_fin = 2980.090 uV 11:44:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 306.171 uVs 11:44:44 Integrated Voltage Measurement... 11:44:52 Voltage Offset Correction: v_off_ini = 2981.010 uV, v_off_fin = 2961.928 uV 11:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.592 uVs 11:44:53 Integrated Voltage Measurement... 11:45:01 Voltage Offset Correction: v_off_ini = 2969.408 uV, v_off_fin = 2986.308 uV 11:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.124 uVs 11:45:04 I2Y Average and RMS of Measurements VT = -288.165 +- 4.978 uVs I2Y = -26.511 +- 0.458 uTm^2 11:45:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:45:13 Integrated Voltage Measurement... 11:45:22 Voltage Offset Correction: v_off_ini = 2969.092 uV, v_off_fin = 2965.482 uV 11:45:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -34.169 uVs 11:45:22 Integrated Voltage Measurement... 11:45:31 Voltage Offset Correction: v_off_ini = 2979.858 uV, v_off_fin = 2983.932 uV 11:45:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.614 uVs 11:45:31 Integrated Voltage Measurement... 11:45:40 Voltage Offset Correction: v_off_ini = 2969.982 uV, v_off_fin = 2970.701 uV 11:45:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.809 uVs 11:45:40 Integrated Voltage Measurement... 11:45:49 Voltage Offset Correction: v_off_ini = 2954.178 uV, v_off_fin = 2955.189 uV 11:45:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.193 uVs 11:45:49 Integrated Voltage Measurement... 11:45:58 Voltage Offset Correction: v_off_ini = 2961.038 uV, v_off_fin = 2958.648 uV 11:45:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.488 uVs 11:45:58 Integrated Voltage Measurement... 11:46:07 Voltage Offset Correction: v_off_ini = 2960.383 uV, v_off_fin = 2954.053 uV 11:46:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 40.737 uVs 11:46:11 I1X Average and RMS of Measurements VT = -42.668 +- 8.173 uVs I1X = 8.534 +- 1.634 uTm 11:46:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:46:18 Integrated Voltage Measurement... 11:46:27 Voltage Offset Correction: v_off_ini = 2942.437 uV, v_off_fin = 2931.955 uV 11:46:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.948 uVs 11:46:27 Integrated Voltage Measurement... 11:46:36 Voltage Offset Correction: v_off_ini = 2968.930 uV, v_off_fin = 2986.135 uV 11:46:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.676 uVs 11:46:36 Integrated Voltage Measurement... 11:46:45 Voltage Offset Correction: v_off_ini = 2990.350 uV, v_off_fin = 2976.601 uV 11:46:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -282.386 uVs 11:46:45 Integrated Voltage Measurement... 11:46:54 Voltage Offset Correction: v_off_ini = 2979.593 uV, v_off_fin = 2990.663 uV 11:46:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 275.999 uVs 11:46:54 Integrated Voltage Measurement... 11:47:03 Voltage Offset Correction: v_off_ini = 2982.765 uV, v_off_fin = 2960.921 uV 11:47:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -274.696 uVs 11:47:03 Integrated Voltage Measurement... 11:47:12 Voltage Offset Correction: v_off_ini = 2983.320 uV, v_off_fin = 2992.358 uV 11:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.718 uVs 11:47:16 I1Y Average and RMS of Measurements VT = -275.737 +- 3.951 uVs I1Y = -55.147 +- 0.790 uTm 11:47:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:47:24 Integrated Voltage Measurement... 11:47:33 Voltage Offset Correction: v_off_ini = 2977.450 uV, v_off_fin = 2975.766 uV 11:47:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.487 uVs 11:47:33 Integrated Voltage Measurement... 11:47:42 Voltage Offset Correction: v_off_ini = 2979.272 uV, v_off_fin = 2993.557 uV 11:47:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.451 uVs 11:47:42 Integrated Voltage Measurement... 11:47:51 Voltage Offset Correction: v_off_ini = 2982.874 uV, v_off_fin = 2985.554 uV 11:47:51 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -31.887 uVs 11:47:51 Integrated Voltage Measurement... 11:48:00 Voltage Offset Correction: v_off_ini = 2982.735 uV, v_off_fin = 2984.994 uV 11:48:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.223 uVs 11:48:00 Integrated Voltage Measurement... 11:48:09 Voltage Offset Correction: v_off_ini = 2986.260 uV, v_off_fin = 2989.320 uV 11:48:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.969 uVs 11:48:09 Integrated Voltage Measurement... 11:48:18 Voltage Offset Correction: v_off_ini = 3000.627 uV, v_off_fin = 3020.824 uV 11:48:18 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 12.672 uVs 11:48:20 I2X Average and RMS of Measurements VT = -22.448 +- 4.191 uVs I2X = 2.065 +- 0.386 uTm^2 11:48:25 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 11:48:28 Integrated Voltage Measurement... 11:48:37 Voltage Offset Correction: v_off_ini = 3005.122 uV, v_off_fin = 2995.824 uV 11:48:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.660 uVs 11:48:37 Integrated Voltage Measurement... 11:48:46 Voltage Offset Correction: v_off_ini = 3000.316 uV, v_off_fin = 2996.002 uV 11:48:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.769 uVs 11:48:46 Integrated Voltage Measurement... 11:48:55 Voltage Offset Correction: v_off_ini = 3018.125 uV, v_off_fin = 2999.503 uV 11:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.014 uVs 11:48:55 Integrated Voltage Measurement... 11:49:04 Voltage Offset Correction: v_off_ini = 2992.632 uV, v_off_fin = 2985.390 uV 11:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.539 uVs 11:49:04 Integrated Voltage Measurement... 11:49:13 Voltage Offset Correction: v_off_ini = 2998.148 uV, v_off_fin = 2993.556 uV 11:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.815 uVs 11:49:13 Integrated Voltage Measurement... 11:49:22 Voltage Offset Correction: v_off_ini = 2966.790 uV, v_off_fin = 2978.343 uV 11:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.266 uVs 11:49:24 I2Y Average and RMS of Measurements VT = -293.844 +- 9.633 uVs I2Y = -27.034 +- 0.886 uTm^2 11:49:29 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:49:33 Integrated Voltage Measurement... 11:49:42 Voltage Offset Correction: v_off_ini = 3006.858 uV, v_off_fin = 2994.831 uV 11:49:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.859 uVs 11:49:42 Integrated Voltage Measurement... 11:49:51 Voltage Offset Correction: v_off_ini = 2999.983 uV, v_off_fin = 3004.160 uV 11:49:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.855 uVs 11:49:51 Integrated Voltage Measurement... 11:50:00 Voltage Offset Correction: v_off_ini = 3012.553 uV, v_off_fin = 3007.772 uV 11:50:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -9.870 uVs 11:50:00 Integrated Voltage Measurement... 11:50:09 Voltage Offset Correction: v_off_ini = 3021.879 uV, v_off_fin = 3011.659 uV 11:50:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.210 uVs 11:50:09 Integrated Voltage Measurement... 11:50:18 Voltage Offset Correction: v_off_ini = 3002.149 uV, v_off_fin = 2990.508 uV 11:50:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.209 uVs 11:50:18 Integrated Voltage Measurement... 11:50:27 Voltage Offset Correction: v_off_ini = 2979.050 uV, v_off_fin = 2994.555 uV 11:50:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 28.609 uVs 11:50:31 I1X Average and RMS of Measurements VT = -28.769 +- 11.351 uVs I1X = 5.754 +- 2.270 uTm 11:50:34 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:50:38 Integrated Voltage Measurement... 11:50:47 Voltage Offset Correction: v_off_ini = 3002.123 uV, v_off_fin = 2981.720 uV 11:50:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -278.753 uVs 11:50:47 Integrated Voltage Measurement... 11:50:56 Voltage Offset Correction: v_off_ini = 3006.822 uV, v_off_fin = 3035.472 uV 11:50:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.427 uVs 11:50:56 Integrated Voltage Measurement... 11:51:05 Voltage Offset Correction: v_off_ini = 3044.951 uV, v_off_fin = 3006.359 uV 11:51:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.443 uVs 11:51:05 Integrated Voltage Measurement... 11:51:14 Voltage Offset Correction: v_off_ini = 3017.266 uV, v_off_fin = 3014.307 uV 11:51:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 281.857 uVs 11:51:14 Integrated Voltage Measurement... 11:51:23 Voltage Offset Correction: v_off_ini = 3013.394 uV, v_off_fin = 2998.339 uV 11:51:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -275.638 uVs 11:51:23 Integrated Voltage Measurement... 11:51:32 Voltage Offset Correction: v_off_ini = 3011.020 uV, v_off_fin = 3023.506 uV 11:51:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 284.264 uVs 11:51:36 I1Y Average and RMS of Measurements VT = -281.731 +- 3.907 uVs I1Y = -56.346 +- 0.781 uTm 11:51:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:51:44 Integrated Voltage Measurement... 11:51:53 Voltage Offset Correction: v_off_ini = 2997.392 uV, v_off_fin = 2987.423 uV 11:51:53 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -2.871 uVs 11:51:53 Integrated Voltage Measurement... 11:52:02 Voltage Offset Correction: v_off_ini = 3000.317 uV, v_off_fin = 3007.962 uV 11:52:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -9.646 uVs 11:52:02 Integrated Voltage Measurement... 11:52:11 Voltage Offset Correction: v_off_ini = 3021.932 uV, v_off_fin = 3003.477 uV 11:52:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.357 uVs 11:52:11 Integrated Voltage Measurement... 11:52:20 Voltage Offset Correction: v_off_ini = 3031.841 uV, v_off_fin = 3045.804 uV 11:52:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -11.841 uVs 11:52:20 Integrated Voltage Measurement... 11:52:29 Voltage Offset Correction: v_off_ini = 2996.311 uV, v_off_fin = 2998.299 uV 11:52:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 14.305 uVs 11:52:29 Integrated Voltage Measurement... 11:52:38 Voltage Offset Correction: v_off_ini = 3035.745 uV, v_off_fin = 3033.403 uV 11:52:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.027 uVs 11:52:40 I2X Average and RMS of Measurements VT = 4.932 +- 4.196 uVs I2X = -0.454 +- 0.386 uTm^2 11:52:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 11:52:48 Integrated Voltage Measurement... 11:52:57 Voltage Offset Correction: v_off_ini = 3014.314 uV, v_off_fin = 3019.918 uV 11:52:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.630 uVs 11:52:57 Integrated Voltage Measurement... 11:53:06 Voltage Offset Correction: v_off_ini = 3017.389 uV, v_off_fin = 3017.700 uV 11:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.667 uVs 11:53:06 Integrated Voltage Measurement... 11:53:15 Voltage Offset Correction: v_off_ini = 2996.616 uV, v_off_fin = 3020.449 uV 11:53:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.962 uVs 11:53:15 Integrated Voltage Measurement... 11:53:24 Voltage Offset Correction: v_off_ini = 3001.613 uV, v_off_fin = 3009.409 uV 11:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.738 uVs 11:53:24 Integrated Voltage Measurement... 11:53:33 Voltage Offset Correction: v_off_ini = 3004.806 uV, v_off_fin = 2998.221 uV 11:53:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.134 uVs 11:53:33 Integrated Voltage Measurement... 11:53:42 Voltage Offset Correction: v_off_ini = 3007.406 uV, v_off_fin = 3004.477 uV 11:53:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 291.282 uVs 11:53:45 I2Y Average and RMS of Measurements VT = -290.735 +- 9.683 uVs I2Y = -26.748 +- 0.891 uTm^2 11:53:49 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:53:54 Integrated Voltage Measurement... 11:54:03 Voltage Offset Correction: v_off_ini = 3017.697 uV, v_off_fin = 3011.600 uV 11:54:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -8.484 uVs 11:54:03 Integrated Voltage Measurement... 11:54:12 Voltage Offset Correction: v_off_ini = 3008.245 uV, v_off_fin = 3023.539 uV 11:54:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -23.294 uVs 11:54:12 Integrated Voltage Measurement... 11:54:21 Voltage Offset Correction: v_off_ini = 3028.674 uV, v_off_fin = 3003.146 uV 11:54:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -4.032 uVs 11:54:21 Integrated Voltage Measurement... 11:54:30 Voltage Offset Correction: v_off_ini = 3021.007 uV, v_off_fin = 3004.933 uV 11:54:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -9.725 uVs 11:54:30 Integrated Voltage Measurement... 11:54:39 Voltage Offset Correction: v_off_ini = 3010.212 uV, v_off_fin = 3015.417 uV 11:54:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 14.112 uVs 11:54:39 Integrated Voltage Measurement... 11:54:48 Voltage Offset Correction: v_off_ini = 3012.657 uV, v_off_fin = 3022.206 uV 11:54:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -8.733 uVs 11:54:52 I1X Average and RMS of Measurements VT = 7.225 +- 3.503 uVs I1X = -1.445 +- 0.701 uTm 11:54:54 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:54:59 Integrated Voltage Measurement... 11:55:08 Voltage Offset Correction: v_off_ini = 3016.300 uV, v_off_fin = 3018.176 uV 11:55:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -281.374 uVs 11:55:08 Integrated Voltage Measurement... 11:55:17 Voltage Offset Correction: v_off_ini = 3030.566 uV, v_off_fin = 3030.513 uV 11:55:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.469 uVs 11:55:17 Integrated Voltage Measurement... 11:55:26 Voltage Offset Correction: v_off_ini = 3031.793 uV, v_off_fin = 3027.684 uV 11:55:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -290.843 uVs 11:55:26 Integrated Voltage Measurement... 11:55:35 Voltage Offset Correction: v_off_ini = 3021.959 uV, v_off_fin = 3018.254 uV 11:55:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 304.114 uVs 11:55:35 Integrated Voltage Measurement... 11:55:44 Voltage Offset Correction: v_off_ini = 3056.639 uV, v_off_fin = 3024.129 uV 11:55:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.776 uVs 11:55:44 Integrated Voltage Measurement... 11:55:53 Voltage Offset Correction: v_off_ini = 3064.836 uV, v_off_fin = 3066.828 uV 11:55:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.041 uVs 11:55:57 I1Y Average and RMS of Measurements VT = -288.603 +- 6.541 uVs I1Y = -57.721 +- 1.308 uTm 11:56:02 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:56:04 Integrated Voltage Measurement... 11:56:13 Voltage Offset Correction: v_off_ini = 3054.196 uV, v_off_fin = 3045.509 uV 11:56:13 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 19.094 uVs 11:56:13 Integrated Voltage Measurement... 11:56:22 Voltage Offset Correction: v_off_ini = 3041.555 uV, v_off_fin = 3035.775 uV 11:56:22 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -39.437 uVs 11:56:22 Integrated Voltage Measurement... 11:56:31 Voltage Offset Correction: v_off_ini = 3034.738 uV, v_off_fin = 3030.399 uV 11:56:31 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 47.682 uVs 11:56:31 Integrated Voltage Measurement... 11:56:40 Voltage Offset Correction: v_off_ini = 3017.457 uV, v_off_fin = 3023.898 uV 11:56:40 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -48.871 uVs 11:56:41 Integrated Voltage Measurement... 11:56:50 Voltage Offset Correction: v_off_ini = 3025.132 uV, v_off_fin = 3015.088 uV 11:56:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 18.428 uVs 11:56:50 Integrated Voltage Measurement... 11:56:59 Voltage Offset Correction: v_off_ini = 3031.013 uV, v_off_fin = 3037.696 uV 11:56:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -18.911 uVs 11:57:01 I2X Average and RMS of Measurements VT = 32.070 +- 12.249 uVs I2X = -2.951 +- 1.127 uTm^2 11:57:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 11:57:09 Integrated Voltage Measurement... 11:57:18 Voltage Offset Correction: v_off_ini = 3005.819 uV, v_off_fin = 3022.752 uV 11:57:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -322.025 uVs 11:57:18 Integrated Voltage Measurement... 11:57:27 Voltage Offset Correction: v_off_ini = 3020.721 uV, v_off_fin = 3015.816 uV 11:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.173 uVs 11:57:27 Integrated Voltage Measurement... 11:57:36 Voltage Offset Correction: v_off_ini = 3032.526 uV, v_off_fin = 3022.120 uV 11:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.165 uVs 11:57:36 Integrated Voltage Measurement... 11:57:45 Voltage Offset Correction: v_off_ini = 3031.349 uV, v_off_fin = 3047.909 uV 11:57:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 313.326 uVs 11:57:45 Integrated Voltage Measurement... 11:57:54 Voltage Offset Correction: v_off_ini = 3010.202 uV, v_off_fin = 2991.552 uV 11:57:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.850 uVs 11:57:54 Integrated Voltage Measurement... 11:58:03 Voltage Offset Correction: v_off_ini = 2992.489 uV, v_off_fin = 3019.706 uV 11:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 325.546 uVs 11:58:05 I2Y Average and RMS of Measurements VT = -314.681 +- 10.163 uVs I2Y = -28.951 +- 0.935 uTm^2 11:58:13 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:58:17 Integrated Voltage Measurement... 11:58:26 Voltage Offset Correction: v_off_ini = 3016.885 uV, v_off_fin = 3005.156 uV 11:58:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -75.334 uVs 11:58:26 Integrated Voltage Measurement... 11:58:35 Voltage Offset Correction: v_off_ini = 3028.017 uV, v_off_fin = 3023.333 uV 11:58:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 47.963 uVs 11:58:35 Integrated Voltage Measurement... 11:58:44 Voltage Offset Correction: v_off_ini = 3038.225 uV, v_off_fin = 3015.401 uV 11:58:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.897 uVs 11:58:44 Integrated Voltage Measurement... 11:58:53 Voltage Offset Correction: v_off_ini = 3017.920 uV, v_off_fin = 3018.053 uV 11:58:53 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.461 uVs 11:58:53 Integrated Voltage Measurement... 11:59:02 Voltage Offset Correction: v_off_ini = 3035.367 uV, v_off_fin = 3022.820 uV 11:59:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.070 uVs 11:59:02 Integrated Voltage Measurement... 11:59:11 Voltage Offset Correction: v_off_ini = 3023.010 uV, v_off_fin = 3007.565 uV 11:59:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.106 uVs 11:59:15 I1X Average and RMS of Measurements VT = -51.139 +- 7.879 uVs I1X = 10.228 +- 1.576 uTm 11:59:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 11:59:22 Integrated Voltage Measurement... 11:59:31 Voltage Offset Correction: v_off_ini = 3050.250 uV, v_off_fin = 3021.306 uV 11:59:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -287.094 uVs 11:59:31 Integrated Voltage Measurement... 11:59:40 Voltage Offset Correction: v_off_ini = 3033.991 uV, v_off_fin = 3050.189 uV 11:59:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 282.819 uVs 11:59:40 Integrated Voltage Measurement... 11:59:49 Voltage Offset Correction: v_off_ini = 3045.991 uV, v_off_fin = 3018.998 uV 11:59:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -290.365 uVs 11:59:49 Integrated Voltage Measurement... 11:59:58 Voltage Offset Correction: v_off_ini = 3024.483 uV, v_off_fin = 3043.754 uV 11:59:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 312.319 uVs 11:59:58 Integrated Voltage Measurement... 12:00:07 Voltage Offset Correction: v_off_ini = 3024.388 uV, v_off_fin = 3018.803 uV 12:00:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -291.221 uVs 12:00:07 Integrated Voltage Measurement... 12:00:16 Voltage Offset Correction: v_off_ini = 3031.969 uV, v_off_fin = 3053.558 uV 12:00:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 286.124 uVs 12:00:20 I1Y Average and RMS of Measurements VT = -291.657 +- 7.014 uVs I1Y = -58.331 +- 1.403 uTm 12:00:23 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:00:25 Integrated Voltage Measurement... 12:00:34 Voltage Offset Correction: v_off_ini = 3029.329 uV, v_off_fin = 3039.893 uV 12:00:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.351 uVs 12:00:34 Integrated Voltage Measurement... 12:00:43 Voltage Offset Correction: v_off_ini = 3031.439 uV, v_off_fin = 3054.447 uV 12:00:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.545 uVs 12:00:43 Integrated Voltage Measurement... 12:00:52 Voltage Offset Correction: v_off_ini = 3050.360 uV, v_off_fin = 3025.789 uV 12:00:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.047 uVs 12:00:52 Integrated Voltage Measurement... 12:01:01 Voltage Offset Correction: v_off_ini = 3031.619 uV, v_off_fin = 3030.075 uV 12:01:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 31.209 uVs 12:01:01 Integrated Voltage Measurement... 12:01:10 Voltage Offset Correction: v_off_ini = 3029.405 uV, v_off_fin = 3038.140 uV 12:01:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 0.226 uVs 12:01:11 Integrated Voltage Measurement... 12:01:19 Voltage Offset Correction: v_off_ini = 3034.968 uV, v_off_fin = 3029.583 uV 12:01:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.097 uVs 12:01:22 I2X Average and RMS of Measurements VT = -23.004 +- 9.783 uVs I2X = 2.116 +- 0.900 uTm^2 12:01:24 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:01:27 Integrated Voltage Measurement... 12:01:36 Voltage Offset Correction: v_off_ini = 3009.547 uV, v_off_fin = 3009.297 uV 12:01:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -323.987 uVs 12:01:36 Integrated Voltage Measurement... 12:01:45 Voltage Offset Correction: v_off_ini = 3032.689 uV, v_off_fin = 3022.791 uV 12:01:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 323.331 uVs 12:01:45 Integrated Voltage Measurement... 12:01:54 Voltage Offset Correction: v_off_ini = 3000.224 uV, v_off_fin = 3011.218 uV 12:01:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.147 uVs 12:01:54 Integrated Voltage Measurement... 12:02:03 Voltage Offset Correction: v_off_ini = 3009.716 uV, v_off_fin = 3027.958 uV 12:02:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 324.695 uVs 12:02:03 Integrated Voltage Measurement... 12:02:12 Voltage Offset Correction: v_off_ini = 3000.944 uV, v_off_fin = 3011.900 uV 12:02:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -299.007 uVs 12:02:12 Integrated Voltage Measurement... 12:02:21 Voltage Offset Correction: v_off_ini = 3010.294 uV, v_off_fin = 3015.967 uV 12:02:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 302.130 uVs 12:02:24 I2Y Average and RMS of Measurements VT = -314.549 +- 10.036 uVs I2Y = -28.939 +- 0.923 uTm^2 12:02:28 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:02:32 Integrated Voltage Measurement... 12:02:41 Voltage Offset Correction: v_off_ini = 2981.255 uV, v_off_fin = 2979.092 uV 12:02:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -23.876 uVs 12:02:41 Integrated Voltage Measurement... 12:02:50 Voltage Offset Correction: v_off_ini = 2996.980 uV, v_off_fin = 2986.380 uV 12:02:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.874 uVs 12:02:50 Integrated Voltage Measurement... 12:02:59 Voltage Offset Correction: v_off_ini = 3005.234 uV, v_off_fin = 3005.299 uV 12:02:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.331 uVs 12:02:59 Integrated Voltage Measurement... 12:03:08 Voltage Offset Correction: v_off_ini = 3004.456 uV, v_off_fin = 3024.253 uV 12:03:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.443 uVs 12:03:08 Integrated Voltage Measurement... 12:03:17 Voltage Offset Correction: v_off_ini = 3022.870 uV, v_off_fin = 3023.659 uV 12:03:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.511 uVs 12:03:17 Integrated Voltage Measurement... 12:03:26 Voltage Offset Correction: v_off_ini = 3021.031 uV, v_off_fin = 3009.230 uV 12:03:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.967 uVs 12:03:30 I1X Average and RMS of Measurements VT = -41.000 +- 10.581 uVs I1X = 8.200 +- 2.116 uTm 12:03:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:03:37 Integrated Voltage Measurement... 12:03:46 Voltage Offset Correction: v_off_ini = 3030.989 uV, v_off_fin = 3003.062 uV 12:03:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -289.925 uVs 12:03:46 Integrated Voltage Measurement... 12:03:55 Voltage Offset Correction: v_off_ini = 3037.508 uV, v_off_fin = 3038.855 uV 12:03:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.189 uVs 12:03:55 Integrated Voltage Measurement... 12:04:04 Voltage Offset Correction: v_off_ini = 3057.368 uV, v_off_fin = 3041.723 uV 12:04:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -295.733 uVs 12:04:04 Integrated Voltage Measurement... 12:04:13 Voltage Offset Correction: v_off_ini = 3037.255 uV, v_off_fin = 3036.723 uV 12:04:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.296 uVs 12:04:13 Integrated Voltage Measurement... 12:04:22 Voltage Offset Correction: v_off_ini = 3037.064 uV, v_off_fin = 3008.987 uV 12:04:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -309.537 uVs 12:04:22 Integrated Voltage Measurement... 12:04:31 Voltage Offset Correction: v_off_ini = 3014.074 uV, v_off_fin = 3022.820 uV 12:04:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.070 uVs 12:04:35 I1Y Average and RMS of Measurements VT = -286.792 +- 4.417 uVs I1Y = -57.358 +- 0.883 uTm 12:04:37 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:04:40 Integrated Voltage Measurement... 12:04:49 Voltage Offset Correction: v_off_ini = 3003.786 uV, v_off_fin = 3002.572 uV 12:04:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -13.772 uVs 12:04:49 Integrated Voltage Measurement... 12:04:58 Voltage Offset Correction: v_off_ini = 2996.383 uV, v_off_fin = 3025.766 uV 12:04:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.566 uVs 12:04:58 Integrated Voltage Measurement... 12:05:07 Voltage Offset Correction: v_off_ini = 3013.804 uV, v_off_fin = 2975.728 uV 12:05:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.685 uVs 12:05:07 Integrated Voltage Measurement... 12:05:16 Voltage Offset Correction: v_off_ini = 2997.174 uV, v_off_fin = 3025.567 uV 12:05:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.092 uVs 12:05:16 Integrated Voltage Measurement... 12:05:25 Voltage Offset Correction: v_off_ini = 3002.463 uV, v_off_fin = 3005.538 uV 12:05:25 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -16.289 uVs 12:05:25 Integrated Voltage Measurement... 12:05:34 Voltage Offset Correction: v_off_ini = 2975.742 uV, v_off_fin = 3008.073 uV 12:05:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.133 uVs 12:05:37 I2X Average and RMS of Measurements VT = -22.590 +- 0.565 uVs I2X = 2.078 +- 0.052 uTm^2 12:05:39 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:05:42 Integrated Voltage Measurement... 12:05:51 Voltage Offset Correction: v_off_ini = 2992.368 uV, v_off_fin = 2998.983 uV 12:05:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -314.906 uVs 12:05:51 Integrated Voltage Measurement... 12:06:00 Voltage Offset Correction: v_off_ini = 2989.836 uV, v_off_fin = 2989.274 uV 12:06:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 309.728 uVs 12:06:00 Integrated Voltage Measurement... 12:06:09 Voltage Offset Correction: v_off_ini = 2996.139 uV, v_off_fin = 2990.197 uV 12:06:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.112 uVs 12:06:09 Integrated Voltage Measurement... 12:06:18 Voltage Offset Correction: v_off_ini = 3005.543 uV, v_off_fin = 3005.300 uV 12:06:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 308.027 uVs 12:06:18 Integrated Voltage Measurement... 12:06:27 Voltage Offset Correction: v_off_ini = 3016.717 uV, v_off_fin = 3021.783 uV 12:06:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -315.214 uVs 12:06:27 Integrated Voltage Measurement... 12:06:36 Voltage Offset Correction: v_off_ini = 3026.932 uV, v_off_fin = 3020.817 uV 12:06:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 315.313 uVs 12:06:38 I2Y Average and RMS of Measurements VT = -307.717 +- 8.673 uVs I2Y = -28.310 +- 0.798 uTm^2 12:06:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:06:47 Integrated Voltage Measurement... 12:06:56 Voltage Offset Correction: v_off_ini = 3026.260 uV, v_off_fin = 2996.749 uV 12:06:56 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.457 uVs 12:06:56 Integrated Voltage Measurement... 12:07:05 Voltage Offset Correction: v_off_ini = 2989.029 uV, v_off_fin = 2976.906 uV 12:07:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 39.198 uVs 12:07:05 Integrated Voltage Measurement... 12:07:14 Voltage Offset Correction: v_off_ini = 2980.634 uV, v_off_fin = 2984.520 uV 12:07:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.449 uVs 12:07:14 Integrated Voltage Measurement... 12:07:23 Voltage Offset Correction: v_off_ini = 3013.914 uV, v_off_fin = 3009.427 uV 12:07:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 65.970 uVs 12:07:23 Integrated Voltage Measurement... 12:07:32 Voltage Offset Correction: v_off_ini = 2996.958 uV, v_off_fin = 2986.176 uV 12:07:32 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -27.548 uVs 12:07:32 Integrated Voltage Measurement... 12:07:41 Voltage Offset Correction: v_off_ini = 3012.934 uV, v_off_fin = 3025.421 uV 12:07:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 52.450 uVs 12:07:45 I1X Average and RMS of Measurements VT = -41.012 +- 9.165 uVs I1X = 8.203 +- 1.833 uTm 12:07:47 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:07:52 Integrated Voltage Measurement... 12:08:00 Voltage Offset Correction: v_off_ini = 3022.944 uV, v_off_fin = 3004.736 uV 12:08:00 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.093 uVs 12:08:01 Integrated Voltage Measurement... 12:08:09 Voltage Offset Correction: v_off_ini = 3022.173 uV, v_off_fin = 3013.102 uV 12:08:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 276.031 uVs 12:08:10 Integrated Voltage Measurement... 12:08:18 Voltage Offset Correction: v_off_ini = 3028.363 uV, v_off_fin = 3006.958 uV 12:08:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -298.177 uVs 12:08:19 Integrated Voltage Measurement... 12:08:27 Voltage Offset Correction: v_off_ini = 3015.327 uV, v_off_fin = 3035.718 uV 12:08:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.458 uVs 12:08:28 Integrated Voltage Measurement... 12:08:36 Voltage Offset Correction: v_off_ini = 3026.953 uV, v_off_fin = 3013.640 uV 12:08:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -285.473 uVs 12:08:37 Integrated Voltage Measurement... 12:08:45 Voltage Offset Correction: v_off_ini = 3001.285 uV, v_off_fin = 3027.683 uV 12:08:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 278.011 uVs 12:08:50 I1Y Average and RMS of Measurements VT = -280.041 +- 5.544 uVs I1Y = -56.009 +- 1.108 uTm 12:08:52 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:08:55 Integrated Voltage Measurement... 12:09:04 Voltage Offset Correction: v_off_ini = 3026.110 uV, v_off_fin = 3031.399 uV 12:09:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.409 uVs 12:09:04 Integrated Voltage Measurement... 12:09:13 Voltage Offset Correction: v_off_ini = 3031.039 uV, v_off_fin = 3035.877 uV 12:09:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.615 uVs 12:09:13 Integrated Voltage Measurement... 12:09:22 Voltage Offset Correction: v_off_ini = 3019.594 uV, v_off_fin = 3011.392 uV 12:09:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.855 uVs 12:09:22 Integrated Voltage Measurement... 12:09:31 Voltage Offset Correction: v_off_ini = 3017.023 uV, v_off_fin = 3049.722 uV 12:09:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.583 uVs 12:09:31 Integrated Voltage Measurement... 12:09:40 Voltage Offset Correction: v_off_ini = 3045.743 uV, v_off_fin = 3031.886 uV 12:09:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.129 uVs 12:09:40 Integrated Voltage Measurement... 12:09:49 Voltage Offset Correction: v_off_ini = 3025.242 uV, v_off_fin = 3034.602 uV 12:09:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -3.643 uVs 12:09:51 I2X Average and RMS of Measurements VT = -12.158 +- 2.205 uVs I2X = 1.119 +- 0.203 uTm^2 12:09:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:09:56 Integrated Voltage Measurement... 12:10:05 Voltage Offset Correction: v_off_ini = 3038.943 uV, v_off_fin = 3021.266 uV 12:10:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -298.682 uVs 12:10:05 Integrated Voltage Measurement... 12:10:14 Voltage Offset Correction: v_off_ini = 2996.742 uV, v_off_fin = 3002.480 uV 12:10:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 293.531 uVs 12:10:14 Integrated Voltage Measurement... 12:10:23 Voltage Offset Correction: v_off_ini = 3016.767 uV, v_off_fin = 2997.703 uV 12:10:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.956 uVs 12:10:24 Integrated Voltage Measurement... 12:10:32 Voltage Offset Correction: v_off_ini = 3025.766 uV, v_off_fin = 3025.653 uV 12:10:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.683 uVs 12:10:33 Integrated Voltage Measurement... 12:10:42 Voltage Offset Correction: v_off_ini = 2999.998 uV, v_off_fin = 3000.501 uV 12:10:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -289.829 uVs 12:10:42 Integrated Voltage Measurement... 12:10:51 Voltage Offset Correction: v_off_ini = 3012.244 uV, v_off_fin = 3018.886 uV 12:10:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 295.091 uVs 12:10:53 I2Y Average and RMS of Measurements VT = -297.295 +- 4.512 uVs I2Y = -27.351 +- 0.415 uTm^2 12:10:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:11:01 Integrated Voltage Measurement... 12:11:10 Voltage Offset Correction: v_off_ini = 3056.637 uV, v_off_fin = 3030.780 uV 12:11:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.020 uVs 12:11:10 Integrated Voltage Measurement... 12:11:19 Voltage Offset Correction: v_off_ini = 3029.505 uV, v_off_fin = 3054.433 uV 12:11:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.702 uVs 12:11:19 Integrated Voltage Measurement... 12:11:28 Voltage Offset Correction: v_off_ini = 3059.495 uV, v_off_fin = 3052.240 uV 12:11:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.888 uVs 12:11:28 Integrated Voltage Measurement... 12:11:37 Voltage Offset Correction: v_off_ini = 3051.016 uV, v_off_fin = 3050.237 uV 12:11:37 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.707 uVs 12:11:37 Integrated Voltage Measurement... 12:11:46 Voltage Offset Correction: v_off_ini = 3042.228 uV, v_off_fin = 3033.168 uV 12:11:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.404 uVs 12:11:46 Integrated Voltage Measurement... 12:11:55 Voltage Offset Correction: v_off_ini = 3023.527 uV, v_off_fin = 3029.159 uV 12:11:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 27.959 uVs 12:12:00 I1X Average and RMS of Measurements VT = -37.447 +- 9.801 uVs I1X = 7.489 +- 1.960 uTm 12:12:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:12:06 Integrated Voltage Measurement... 12:12:15 Voltage Offset Correction: v_off_ini = 3034.538 uV, v_off_fin = 3020.953 uV 12:12:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.708 uVs 12:12:15 Integrated Voltage Measurement... 12:12:24 Voltage Offset Correction: v_off_ini = 3052.879 uV, v_off_fin = 3077.963 uV 12:12:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.308 uVs 12:12:24 Integrated Voltage Measurement... 12:12:33 Voltage Offset Correction: v_off_ini = 3059.785 uV, v_off_fin = 3034.492 uV 12:12:33 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -269.800 uVs 12:12:33 Integrated Voltage Measurement... 12:12:42 Voltage Offset Correction: v_off_ini = 3045.261 uV, v_off_fin = 3034.132 uV 12:12:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.451 uVs 12:12:42 Integrated Voltage Measurement... 12:12:51 Voltage Offset Correction: v_off_ini = 3017.249 uV, v_off_fin = 2992.138 uV 12:12:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -272.886 uVs 12:12:51 Integrated Voltage Measurement... 12:13:00 Voltage Offset Correction: v_off_ini = 3002.266 uV, v_off_fin = 3013.343 uV 12:13:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 273.406 uVs 12:13:04 I1Y Average and RMS of Measurements VT = -265.760 +- 8.724 uVs I1Y = -53.152 +- 1.745 uTm 12:13:07 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:13:09 Integrated Voltage Measurement... 12:13:18 Voltage Offset Correction: v_off_ini = 2997.850 uV, v_off_fin = 2995.572 uV 12:13:18 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -27.411 uVs 12:13:18 Integrated Voltage Measurement... 12:13:27 Voltage Offset Correction: v_off_ini = 3028.633 uV, v_off_fin = 3034.384 uV 12:13:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 5.445 uVs 12:13:27 Integrated Voltage Measurement... 12:13:36 Voltage Offset Correction: v_off_ini = 3044.425 uV, v_off_fin = 3035.936 uV 12:13:36 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -47.537 uVs 12:13:37 Integrated Voltage Measurement... 12:13:45 Voltage Offset Correction: v_off_ini = 3042.342 uV, v_off_fin = 3045.295 uV 12:13:46 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 28.783 uVs 12:13:46 Integrated Voltage Measurement... 12:13:55 Voltage Offset Correction: v_off_ini = 3037.261 uV, v_off_fin = 3023.406 uV 12:13:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -11.327 uVs 12:13:55 Integrated Voltage Measurement... 12:14:04 Voltage Offset Correction: v_off_ini = 3047.263 uV, v_off_fin = 3047.155 uV 12:14:04 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.702 uVs 12:14:06 I2X Average and RMS of Measurements VT = -21.534 +- 12.044 uVs I2X = 1.981 +- 1.108 uTm^2 12:14:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:14:11 Integrated Voltage Measurement... 12:14:20 Voltage Offset Correction: v_off_ini = 3044.505 uV, v_off_fin = 3034.051 uV 12:14:20 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -285.105 uVs 12:14:20 Integrated Voltage Measurement... 12:14:29 Voltage Offset Correction: v_off_ini = 3040.272 uV, v_off_fin = 3044.988 uV 12:14:29 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.609 uVs 12:14:29 Integrated Voltage Measurement... 12:14:38 Voltage Offset Correction: v_off_ini = 3027.666 uV, v_off_fin = 3030.636 uV 12:14:38 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -286.203 uVs 12:14:38 Integrated Voltage Measurement... 12:14:47 Voltage Offset Correction: v_off_ini = 3027.783 uV, v_off_fin = 3027.115 uV 12:14:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 301.217 uVs 12:14:47 Integrated Voltage Measurement... 12:14:56 Voltage Offset Correction: v_off_ini = 3020.044 uV, v_off_fin = 3013.597 uV 12:14:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.978 uVs 12:14:56 Integrated Voltage Measurement... 12:15:05 Voltage Offset Correction: v_off_ini = 3015.678 uV, v_off_fin = 3018.295 uV 12:15:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.032 uVs 12:15:08 I2Y Average and RMS of Measurements VT = -288.357 +- 7.322 uVs I2Y = -26.529 +- 0.674 uTm^2 12:15:12 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:15:16 Integrated Voltage Measurement... 12:15:25 Voltage Offset Correction: v_off_ini = 3047.425 uV, v_off_fin = 3043.250 uV 12:15:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -54.774 uVs 12:15:25 Integrated Voltage Measurement... 12:15:34 Voltage Offset Correction: v_off_ini = 3040.951 uV, v_off_fin = 3040.048 uV 12:15:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 11.891 uVs 12:15:34 Integrated Voltage Measurement... 12:15:43 Voltage Offset Correction: v_off_ini = 3032.596 uV, v_off_fin = 3024.605 uV 12:15:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.694 uVs 12:15:43 Integrated Voltage Measurement... 12:15:52 Voltage Offset Correction: v_off_ini = 3012.711 uV, v_off_fin = 3026.806 uV 12:15:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 31.995 uVs 12:15:52 Integrated Voltage Measurement... 12:16:01 Voltage Offset Correction: v_off_ini = 3026.231 uV, v_off_fin = 2991.462 uV 12:16:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.868 uVs 12:16:01 Integrated Voltage Measurement... 12:16:10 Voltage Offset Correction: v_off_ini = 3026.314 uV, v_off_fin = 3021.543 uV 12:16:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.289 uVs 12:16:14 I1X Average and RMS of Measurements VT = -31.252 +- 2.119 uVs I1X = 6.251 +- 0.424 uTm 12:16:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:16:21 Integrated Voltage Measurement... 12:16:30 Voltage Offset Correction: v_off_ini = 3038.376 uV, v_off_fin = 2986.350 uV 12:16:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -277.184 uVs 12:16:30 Integrated Voltage Measurement... 12:16:39 Voltage Offset Correction: v_off_ini = 3008.695 uV, v_off_fin = 3006.967 uV 12:16:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.647 uVs 12:16:39 Integrated Voltage Measurement... 12:16:48 Voltage Offset Correction: v_off_ini = 3012.958 uV, v_off_fin = 2999.926 uV 12:16:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -251.323 uVs 12:16:48 Integrated Voltage Measurement... 12:16:57 Voltage Offset Correction: v_off_ini = 3002.542 uV, v_off_fin = 3013.239 uV 12:16:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 260.625 uVs 12:16:57 Integrated Voltage Measurement... 12:17:06 Voltage Offset Correction: v_off_ini = 3007.861 uV, v_off_fin = 2998.463 uV 12:17:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -238.906 uVs 12:17:06 Integrated Voltage Measurement... 12:17:15 Voltage Offset Correction: v_off_ini = 2994.534 uV, v_off_fin = 3015.882 uV 12:17:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.632 uVs 12:17:19 I1Y Average and RMS of Measurements VT = -257.219 +- 9.897 uVs I1Y = -51.444 +- 1.979 uTm 12:17:22 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:17:24 Integrated Voltage Measurement... 12:17:33 Voltage Offset Correction: v_off_ini = 2981.192 uV, v_off_fin = 2982.102 uV 12:17:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 20.472 uVs 12:17:33 Integrated Voltage Measurement... 12:17:42 Voltage Offset Correction: v_off_ini = 2992.116 uV, v_off_fin = 3020.383 uV 12:17:42 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -13.013 uVs 12:17:42 Integrated Voltage Measurement... 12:17:51 Voltage Offset Correction: v_off_ini = 3023.728 uV, v_off_fin = 3021.311 uV 12:17:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -10.280 uVs 12:17:51 Integrated Voltage Measurement... 12:18:00 Voltage Offset Correction: v_off_ini = 3035.584 uV, v_off_fin = 3027.839 uV 12:18:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.526 uVs 12:18:00 Integrated Voltage Measurement... 12:18:09 Voltage Offset Correction: v_off_ini = 3011.370 uV, v_off_fin = 2988.105 uV 12:18:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -5.010 uVs 12:18:09 Integrated Voltage Measurement... 12:18:18 Voltage Offset Correction: v_off_ini = 2999.763 uV, v_off_fin = 3014.286 uV 12:18:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -10.234 uVs 12:18:21 I2X Average and RMS of Measurements VT = 1.317 +- 13.155 uVs I2X = -0.121 +- 1.210 uTm^2 12:18:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:18:26 Integrated Voltage Measurement... 12:18:35 Voltage Offset Correction: v_off_ini = 2997.983 uV, v_off_fin = 3010.058 uV 12:18:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.910 uVs 12:18:35 Integrated Voltage Measurement... 12:18:44 Voltage Offset Correction: v_off_ini = 3002.945 uV, v_off_fin = 3007.220 uV 12:18:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.436 uVs 12:18:44 Integrated Voltage Measurement... 12:18:53 Voltage Offset Correction: v_off_ini = 3031.605 uV, v_off_fin = 3018.782 uV 12:18:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.421 uVs 12:18:53 Integrated Voltage Measurement... 12:19:02 Voltage Offset Correction: v_off_ini = 3023.763 uV, v_off_fin = 3024.456 uV 12:19:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.858 uVs 12:19:02 Integrated Voltage Measurement... 12:19:11 Voltage Offset Correction: v_off_ini = 3032.409 uV, v_off_fin = 3047.597 uV 12:19:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.116 uVs 12:19:11 Integrated Voltage Measurement... 12:19:20 Voltage Offset Correction: v_off_ini = 3034.760 uV, v_off_fin = 3022.518 uV 12:19:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.829 uVs 12:19:22 I2Y Average and RMS of Measurements VT = -265.262 +- 6.666 uVs I2Y = -24.404 +- 0.613 uTm^2 12:19:46 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:19:50 Integrated Voltage Measurement... 12:19:59 Voltage Offset Correction: v_off_ini = 3004.870 uV, v_off_fin = 3024.108 uV 12:19:59 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -87.630 uVs 12:19:59 Integrated Voltage Measurement... 12:20:08 Voltage Offset Correction: v_off_ini = 3027.656 uV, v_off_fin = 3014.522 uV 12:20:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 71.519 uVs 12:20:08 Integrated Voltage Measurement... 12:20:17 Voltage Offset Correction: v_off_ini = 2991.413 uV, v_off_fin = 2997.845 uV 12:20:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -84.938 uVs 12:20:17 Integrated Voltage Measurement... 12:20:26 Voltage Offset Correction: v_off_ini = 3011.491 uV, v_off_fin = 3006.959 uV 12:20:26 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 96.829 uVs 12:20:26 Integrated Voltage Measurement... 12:20:35 Voltage Offset Correction: v_off_ini = 2991.098 uV, v_off_fin = 3008.680 uV 12:20:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -82.206 uVs 12:20:35 Integrated Voltage Measurement... 12:20:44 Voltage Offset Correction: v_off_ini = 3013.489 uV, v_off_fin = 3037.236 uV 12:20:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 91.328 uVs 12:20:49 I1X Average and RMS of Measurements VT = -85.742 +- 4.674 uVs I1X = 17.149 +- 0.933 uTm 12:20:51 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:20:55 Integrated Voltage Measurement... 12:21:04 Voltage Offset Correction: v_off_ini = 2985.370 uV, v_off_fin = 2973.930 uV 12:21:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.411 uVs 12:21:04 Integrated Voltage Measurement... 12:21:13 Voltage Offset Correction: v_off_ini = 2990.725 uV, v_off_fin = 3011.317 uV 12:21:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 242.503 uVs 12:21:13 Integrated Voltage Measurement... 12:21:22 Voltage Offset Correction: v_off_ini = 2985.420 uV, v_off_fin = 2988.905 uV 12:21:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.583 uVs 12:21:22 Integrated Voltage Measurement... 12:21:31 Voltage Offset Correction: v_off_ini = 3008.511 uV, v_off_fin = 3024.895 uV 12:21:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.295 uVs 12:21:31 Integrated Voltage Measurement... 12:21:40 Voltage Offset Correction: v_off_ini = 2985.787 uV, v_off_fin = 2982.139 uV 12:21:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.687 uVs 12:21:40 Integrated Voltage Measurement... 12:21:49 Voltage Offset Correction: v_off_ini = 2990.930 uV, v_off_fin = 3013.235 uV 12:21:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.588 uVs 12:21:53 I1Y Average and RMS of Measurements VT = -239.678 +- 0.199 uVs I1Y = -47.936 +- 0.040 uTm 12:21:58 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:22:01 Integrated Voltage Measurement... 12:22:10 Voltage Offset Correction: v_off_ini = 2980.968 uV, v_off_fin = 2983.698 uV 12:22:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -60.691 uVs 12:22:10 Integrated Voltage Measurement... 12:22:19 Voltage Offset Correction: v_off_ini = 3017.945 uV, v_off_fin = 3008.025 uV 12:22:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 84.038 uVs 12:22:19 Integrated Voltage Measurement... 12:22:28 Voltage Offset Correction: v_off_ini = 2996.208 uV, v_off_fin = 2987.601 uV 12:22:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -70.831 uVs 12:22:28 Integrated Voltage Measurement... 12:22:37 Voltage Offset Correction: v_off_ini = 2983.310 uV, v_off_fin = 2985.751 uV 12:22:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 46.490 uVs 12:22:37 Integrated Voltage Measurement... 12:22:46 Voltage Offset Correction: v_off_ini = 2965.349 uV, v_off_fin = 2946.893 uV 12:22:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -71.249 uVs 12:22:46 Integrated Voltage Measurement... 12:22:55 Voltage Offset Correction: v_off_ini = 2971.822 uV, v_off_fin = 2959.819 uV 12:22:55 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 65.229 uVs 12:22:58 I2X Average and RMS of Measurements VT = -66.421 +- 5.741 uVs I2X = 6.111 +- 0.528 uTm^2 12:23:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 12:23:05 Integrated Voltage Measurement... 12:23:14 Voltage Offset Correction: v_off_ini = 2944.450 uV, v_off_fin = 2924.733 uV 12:23:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -272.184 uVs 12:23:14 Integrated Voltage Measurement... 12:23:23 Voltage Offset Correction: v_off_ini = 2900.806 uV, v_off_fin = 2919.653 uV 12:23:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.325 uVs 12:23:23 Integrated Voltage Measurement... 12:23:32 Voltage Offset Correction: v_off_ini = 2914.937 uV, v_off_fin = 2905.956 uV 12:23:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.313 uVs 12:23:32 Integrated Voltage Measurement... 12:23:41 Voltage Offset Correction: v_off_ini = 2911.190 uV, v_off_fin = 2908.964 uV 12:23:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 262.793 uVs 12:23:41 Integrated Voltage Measurement... 12:23:50 Voltage Offset Correction: v_off_ini = 2912.691 uV, v_off_fin = 2905.679 uV 12:23:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -270.992 uVs 12:23:50 Integrated Voltage Measurement... 12:23:59 Voltage Offset Correction: v_off_ini = 2898.787 uV, v_off_fin = 2912.784 uV 12:23:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.532 uVs 12:24:02 I2Y Average and RMS of Measurements VT = -258.523 +- 10.509 uVs I2Y = -23.784 +- 0.967 uTm^2 12:24:06 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:24:11 Integrated Voltage Measurement... 12:24:20 Voltage Offset Correction: v_off_ini = 2899.817 uV, v_off_fin = 2885.825 uV 12:24:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.961 uVs 12:24:20 Integrated Voltage Measurement... 12:24:29 Voltage Offset Correction: v_off_ini = 2896.856 uV, v_off_fin = 2904.831 uV 12:24:29 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.192 uVs 12:24:29 Integrated Voltage Measurement... 12:24:38 Voltage Offset Correction: v_off_ini = 2901.118 uV, v_off_fin = 2896.017 uV 12:24:38 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -70.759 uVs 12:24:38 Integrated Voltage Measurement... 12:24:47 Voltage Offset Correction: v_off_ini = 2894.623 uV, v_off_fin = 2898.707 uV 12:24:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 64.188 uVs 12:24:47 Integrated Voltage Measurement... 12:24:56 Voltage Offset Correction: v_off_ini = 2887.635 uV, v_off_fin = 2906.058 uV 12:24:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -70.816 uVs 12:24:56 Integrated Voltage Measurement... 12:25:05 Voltage Offset Correction: v_off_ini = 2921.161 uV, v_off_fin = 2934.407 uV 12:25:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.997 uVs 12:25:09 I1X Average and RMS of Measurements VT = -60.486 +- 4.953 uVs I1X = 12.098 +- 0.991 uTm 12:25:11 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:25:16 Integrated Voltage Measurement... 12:25:25 Voltage Offset Correction: v_off_ini = 2905.150 uV, v_off_fin = 2878.805 uV 12:25:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -240.874 uVs 12:25:25 Integrated Voltage Measurement... 12:25:34 Voltage Offset Correction: v_off_ini = 2889.283 uV, v_off_fin = 2906.447 uV 12:25:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.139 uVs 12:25:34 Integrated Voltage Measurement... 12:25:43 Voltage Offset Correction: v_off_ini = 2886.297 uV, v_off_fin = 2881.222 uV 12:25:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.854 uVs 12:25:43 Integrated Voltage Measurement... 12:25:52 Voltage Offset Correction: v_off_ini = 2876.903 uV, v_off_fin = 2886.150 uV 12:25:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.704 uVs 12:25:52 Integrated Voltage Measurement... 12:26:01 Voltage Offset Correction: v_off_ini = 2900.645 uV, v_off_fin = 2893.037 uV 12:26:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -242.871 uVs 12:26:01 Integrated Voltage Measurement... 12:26:10 Voltage Offset Correction: v_off_ini = 2895.824 uV, v_off_fin = 2911.040 uV 12:26:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.124 uVs 12:26:14 I1Y Average and RMS of Measurements VT = -246.928 +- 2.967 uVs I1Y = -49.386 +- 0.593 uTm 12:26:19 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:26:21 Integrated Voltage Measurement... 12:26:30 Voltage Offset Correction: v_off_ini = 2913.549 uV, v_off_fin = 2915.015 uV 12:26:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.902 uVs 12:26:30 Integrated Voltage Measurement... 12:26:39 Voltage Offset Correction: v_off_ini = 2930.626 uV, v_off_fin = 2942.848 uV 12:26:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.391 uVs 12:26:40 Integrated Voltage Measurement... 12:26:48 Voltage Offset Correction: v_off_ini = 2922.692 uV, v_off_fin = 2902.484 uV 12:26:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.093 uVs 12:26:49 Integrated Voltage Measurement... 12:26:57 Voltage Offset Correction: v_off_ini = 2920.304 uV, v_off_fin = 2936.938 uV 12:26:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 10.318 uVs 12:26:58 Integrated Voltage Measurement... 12:27:07 Voltage Offset Correction: v_off_ini = 2935.482 uV, v_off_fin = 2904.230 uV 12:27:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.605 uVs 12:27:07 Integrated Voltage Measurement... 12:27:16 Voltage Offset Correction: v_off_ini = 2912.971 uV, v_off_fin = 2923.726 uV 12:27:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 49.206 uVs 12:27:18 I2X Average and RMS of Measurements VT = -26.919 +- 11.958 uVs I2X = 2.477 +- 1.100 uTm^2 12:27:23 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 12:27:26 Integrated Voltage Measurement... 12:27:35 Voltage Offset Correction: v_off_ini = 2941.726 uV, v_off_fin = 2929.699 uV 12:27:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.087 uVs 12:27:35 Integrated Voltage Measurement... 12:27:44 Voltage Offset Correction: v_off_ini = 2919.846 uV, v_off_fin = 2907.730 uV 12:27:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.937 uVs 12:27:44 Integrated Voltage Measurement... 12:27:53 Voltage Offset Correction: v_off_ini = 2915.874 uV, v_off_fin = 2922.261 uV 12:27:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.596 uVs 12:27:53 Integrated Voltage Measurement... 12:28:02 Voltage Offset Correction: v_off_ini = 2925.529 uV, v_off_fin = 2916.764 uV 12:28:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.724 uVs 12:28:02 Integrated Voltage Measurement... 12:28:11 Voltage Offset Correction: v_off_ini = 2927.169 uV, v_off_fin = 2910.367 uV 12:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.476 uVs 12:28:11 Integrated Voltage Measurement... 12:28:20 Voltage Offset Correction: v_off_ini = 2904.131 uV, v_off_fin = 2918.385 uV 12:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.099 uVs 12:28:22 I2Y Average and RMS of Measurements VT = -262.820 +- 4.738 uVs I2Y = -24.179 +- 0.436 uTm^2 12:28:27 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:28:31 Integrated Voltage Measurement... 12:28:40 Voltage Offset Correction: v_off_ini = 2910.742 uV, v_off_fin = 2920.399 uV 12:28:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.565 uVs 12:28:40 Integrated Voltage Measurement... 12:28:49 Voltage Offset Correction: v_off_ini = 2919.866 uV, v_off_fin = 2921.029 uV 12:28:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 38.291 uVs 12:28:49 Integrated Voltage Measurement... 12:28:58 Voltage Offset Correction: v_off_ini = 2925.657 uV, v_off_fin = 2907.395 uV 12:28:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -19.612 uVs 12:28:58 Integrated Voltage Measurement... 12:29:07 Voltage Offset Correction: v_off_ini = 2931.402 uV, v_off_fin = 2934.995 uV 12:29:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.277 uVs 12:29:07 Integrated Voltage Measurement... 12:29:16 Voltage Offset Correction: v_off_ini = 2915.347 uV, v_off_fin = 2929.736 uV 12:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.710 uVs 12:29:16 Integrated Voltage Measurement... 12:29:25 Voltage Offset Correction: v_off_ini = 2924.247 uV, v_off_fin = 2921.089 uV 12:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 44.963 uVs 12:29:29 I1X Average and RMS of Measurements VT = -34.403 +- 1.181 uVs I1X = 6.881 +- 0.236 uTm 12:29:32 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:29:36 Integrated Voltage Measurement... 12:29:45 Voltage Offset Correction: v_off_ini = 2913.770 uV, v_off_fin = 2917.782 uV 12:29:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.603 uVs 12:29:45 Integrated Voltage Measurement... 12:29:54 Voltage Offset Correction: v_off_ini = 2924.632 uV, v_off_fin = 2947.952 uV 12:29:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 252.090 uVs 12:29:54 Integrated Voltage Measurement... 12:30:03 Voltage Offset Correction: v_off_ini = 2940.405 uV, v_off_fin = 2923.066 uV 12:30:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.802 uVs 12:30:03 Integrated Voltage Measurement... 12:30:12 Voltage Offset Correction: v_off_ini = 2935.458 uV, v_off_fin = 2957.270 uV 12:30:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.540 uVs 12:30:12 Integrated Voltage Measurement... 12:30:21 Voltage Offset Correction: v_off_ini = 2940.348 uV, v_off_fin = 2929.020 uV 12:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.052 uVs 12:30:21 Integrated Voltage Measurement... 12:30:30 Voltage Offset Correction: v_off_ini = 2933.649 uV, v_off_fin = 2942.582 uV 12:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.032 uVs 12:30:34 I1Y Average and RMS of Measurements VT = -257.686 +- 2.555 uVs I1Y = -51.537 +- 0.511 uTm 12:30:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:30:41 Integrated Voltage Measurement... 12:30:50 Voltage Offset Correction: v_off_ini = 2922.808 uV, v_off_fin = 2905.415 uV 12:30:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.524 uVs 12:30:50 Integrated Voltage Measurement... 12:30:59 Voltage Offset Correction: v_off_ini = 2919.750 uV, v_off_fin = 2941.529 uV 12:30:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.598 uVs 12:30:59 Integrated Voltage Measurement... 12:31:08 Voltage Offset Correction: v_off_ini = 2921.995 uV, v_off_fin = 2913.905 uV 12:31:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.010 uVs 12:31:08 Integrated Voltage Measurement... 12:31:17 Voltage Offset Correction: v_off_ini = 2928.868 uV, v_off_fin = 2921.080 uV 12:31:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.186 uVs 12:31:17 Integrated Voltage Measurement... 12:31:26 Voltage Offset Correction: v_off_ini = 2927.588 uV, v_off_fin = 2907.986 uV 12:31:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.652 uVs 12:31:26 Integrated Voltage Measurement... 12:31:35 Voltage Offset Correction: v_off_ini = 2913.215 uV, v_off_fin = 2936.264 uV 12:31:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.656 uVs 12:31:38 I2X Average and RMS of Measurements VT = -16.604 +- 2.156 uVs I2X = 1.528 +- 0.198 uTm^2 12:31:43 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:31:46 Integrated Voltage Measurement... 12:31:54 Voltage Offset Correction: v_off_ini = 2914.641 uV, v_off_fin = 2904.690 uV 12:31:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.401 uVs 12:31:55 Integrated Voltage Measurement... 12:32:03 Voltage Offset Correction: v_off_ini = 2900.532 uV, v_off_fin = 2895.156 uV 12:32:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.808 uVs 12:32:04 Integrated Voltage Measurement... 12:32:13 Voltage Offset Correction: v_off_ini = 2865.923 uV, v_off_fin = 2883.845 uV 12:32:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -261.703 uVs 12:32:13 Integrated Voltage Measurement... 12:32:22 Voltage Offset Correction: v_off_ini = 2910.310 uV, v_off_fin = 2888.475 uV 12:32:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.864 uVs 12:32:22 Integrated Voltage Measurement... 12:32:31 Voltage Offset Correction: v_off_ini = 2888.806 uV, v_off_fin = 2894.534 uV 12:32:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.278 uVs 12:32:31 Integrated Voltage Measurement... 12:32:40 Voltage Offset Correction: v_off_ini = 2877.168 uV, v_off_fin = 2882.769 uV 12:32:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.674 uVs 12:32:42 I2Y Average and RMS of Measurements VT = -275.454 +- 9.103 uVs I2Y = -25.342 +- 0.837 uTm^2 12:32:47 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:32:51 Integrated Voltage Measurement... 12:33:00 Voltage Offset Correction: v_off_ini = 2886.113 uV, v_off_fin = 2867.442 uV 12:33:00 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -8.373 uVs 12:33:00 Integrated Voltage Measurement... 12:33:09 Voltage Offset Correction: v_off_ini = 2877.162 uV, v_off_fin = 2883.500 uV 12:33:09 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.342 uVs 12:33:09 Integrated Voltage Measurement... 12:33:18 Voltage Offset Correction: v_off_ini = 2897.077 uV, v_off_fin = 2892.302 uV 12:33:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 3.160 uVs 12:33:18 Integrated Voltage Measurement... 12:33:27 Voltage Offset Correction: v_off_ini = 2897.398 uV, v_off_fin = 2894.814 uV 12:33:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 2.193 uVs 12:33:27 Integrated Voltage Measurement... 12:33:36 Voltage Offset Correction: v_off_ini = 2893.222 uV, v_off_fin = 2888.616 uV 12:33:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -9.576 uVs 12:33:36 Integrated Voltage Measurement... 12:33:45 Voltage Offset Correction: v_off_ini = 2893.416 uV, v_off_fin = 2913.023 uV 12:33:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.649 uVs 12:33:49 I1X Average and RMS of Measurements VT = -11.829 +- 9.073 uVs I1X = 2.366 +- 1.815 uTm 12:33:51 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:33:56 Integrated Voltage Measurement... 12:34:05 Voltage Offset Correction: v_off_ini = 2885.192 uV, v_off_fin = 2858.242 uV 12:34:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -256.356 uVs 12:34:05 Integrated Voltage Measurement... 12:34:14 Voltage Offset Correction: v_off_ini = 2878.072 uV, v_off_fin = 2894.594 uV 12:34:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 291.113 uVs 12:34:14 Integrated Voltage Measurement... 12:34:23 Voltage Offset Correction: v_off_ini = 2905.386 uV, v_off_fin = 2886.594 uV 12:34:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -266.215 uVs 12:34:23 Integrated Voltage Measurement... 12:34:31 Voltage Offset Correction: v_off_ini = 2894.125 uV, v_off_fin = 2896.960 uV 12:34:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.015 uVs 12:34:32 Integrated Voltage Measurement... 12:34:40 Voltage Offset Correction: v_off_ini = 2919.663 uV, v_off_fin = 2878.898 uV 12:34:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -279.782 uVs 12:34:41 Integrated Voltage Measurement... 12:34:49 Voltage Offset Correction: v_off_ini = 2880.163 uV, v_off_fin = 2897.567 uV 12:34:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.498 uVs 12:34:54 I1Y Average and RMS of Measurements VT = -271.330 +- 2.990 uVs I1Y = -54.266 +- 0.598 uTm 12:34:59 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:35:01 Integrated Voltage Measurement... 12:35:10 Voltage Offset Correction: v_off_ini = 2874.572 uV, v_off_fin = 2870.724 uV 12:35:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 9.382 uVs 12:35:10 Integrated Voltage Measurement... 12:35:19 Voltage Offset Correction: v_off_ini = 2877.487 uV, v_off_fin = 2906.374 uV 12:35:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -26.057 uVs 12:35:19 Integrated Voltage Measurement... 12:35:28 Voltage Offset Correction: v_off_ini = 2892.837 uV, v_off_fin = 2895.023 uV 12:35:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 4.833 uVs 12:35:28 Integrated Voltage Measurement... 12:35:37 Voltage Offset Correction: v_off_ini = 2883.299 uV, v_off_fin = 2886.024 uV 12:35:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -17.150 uVs 12:35:37 Integrated Voltage Measurement... 12:35:46 Voltage Offset Correction: v_off_ini = 2870.471 uV, v_off_fin = 2860.267 uV 12:35:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.351 uVs 12:35:46 Integrated Voltage Measurement... 12:35:55 Voltage Offset Correction: v_off_ini = 2858.443 uV, v_off_fin = 2873.531 uV 12:35:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.821 uVs 12:35:58 I2X Average and RMS of Measurements VT = 10.266 +- 6.403 uVs I2X = -0.944 +- 0.589 uTm^2 12:36:03 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 12:36:05 Integrated Voltage Measurement... 12:36:14 Voltage Offset Correction: v_off_ini = 2897.575 uV, v_off_fin = 2888.742 uV 12:36:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.733 uVs 12:36:14 Integrated Voltage Measurement... 12:36:23 Voltage Offset Correction: v_off_ini = 2890.991 uV, v_off_fin = 2898.857 uV 12:36:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 272.052 uVs 12:36:23 Integrated Voltage Measurement... 12:36:32 Voltage Offset Correction: v_off_ini = 2902.876 uV, v_off_fin = 2891.054 uV 12:36:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -262.945 uVs 12:36:32 Integrated Voltage Measurement... 12:36:41 Voltage Offset Correction: v_off_ini = 2893.529 uV, v_off_fin = 2902.301 uV 12:36:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 305.063 uVs 12:36:41 Integrated Voltage Measurement... 12:36:50 Voltage Offset Correction: v_off_ini = 2889.939 uV, v_off_fin = 2867.512 uV 12:36:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.716 uVs 12:36:50 Integrated Voltage Measurement... 12:36:59 Voltage Offset Correction: v_off_ini = 2888.412 uV, v_off_fin = 2892.315 uV 12:36:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.147 uVs 12:37:02 I2Y Average and RMS of Measurements VT = -282.276 +- 5.064 uVs I2Y = -25.969 +- 0.466 uTm^2 12:37:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:37:11 Integrated Voltage Measurement... 12:37:20 Voltage Offset Correction: v_off_ini = 2900.232 uV, v_off_fin = 2900.967 uV 12:37:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 23.788 uVs 12:37:20 Integrated Voltage Measurement... 12:37:29 Voltage Offset Correction: v_off_ini = 2875.104 uV, v_off_fin = 2891.518 uV 12:37:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -8.653 uVs 12:37:29 Integrated Voltage Measurement... 12:37:38 Voltage Offset Correction: v_off_ini = 2890.644 uV, v_off_fin = 2867.620 uV 12:37:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 15.971 uVs 12:37:38 Integrated Voltage Measurement... 12:37:47 Voltage Offset Correction: v_off_ini = 2865.585 uV, v_off_fin = 2908.169 uV 12:37:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 5.297 uVs 12:37:47 Integrated Voltage Measurement... 12:37:56 Voltage Offset Correction: v_off_ini = 2883.997 uV, v_off_fin = 2881.224 uV 12:37:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = 9.258 uVs 12:37:56 Integrated Voltage Measurement... 12:38:05 Voltage Offset Correction: v_off_ini = 2870.402 uV, v_off_fin = 2880.102 uV 12:38:05 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -1.565 uVs 12:38:09 I1X Average and RMS of Measurements VT = 8.990 +- 5.113 uVs I1X = -1.798 +- 1.023 uTm 12:38:11 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:38:16 Integrated Voltage Measurement... 12:38:25 Voltage Offset Correction: v_off_ini = 2907.172 uV, v_off_fin = 2874.004 uV 12:38:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -268.967 uVs 12:38:25 Integrated Voltage Measurement... 12:38:34 Voltage Offset Correction: v_off_ini = 2890.292 uV, v_off_fin = 2898.374 uV 12:38:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 272.293 uVs 12:38:34 Integrated Voltage Measurement... 12:38:42 Voltage Offset Correction: v_off_ini = 2876.003 uV, v_off_fin = 2862.253 uV 12:38:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -270.828 uVs 12:38:43 Integrated Voltage Measurement... 12:38:51 Voltage Offset Correction: v_off_ini = 2894.018 uV, v_off_fin = 2890.266 uV 12:38:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 279.892 uVs 12:38:52 Integrated Voltage Measurement... 12:39:00 Voltage Offset Correction: v_off_ini = 2871.903 uV, v_off_fin = 2881.204 uV 12:39:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.223 uVs 12:39:00 Integrated Voltage Measurement... 12:39:09 Voltage Offset Correction: v_off_ini = 2863.449 uV, v_off_fin = 2890.998 uV 12:39:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 289.282 uVs 12:39:14 I1Y Average and RMS of Measurements VT = -278.915 +- 8.591 uVs I1Y = -55.783 +- 1.718 uTm 12:39:19 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:39:21 Integrated Voltage Measurement... 12:39:30 Voltage Offset Correction: v_off_ini = 2876.920 uV, v_off_fin = 2869.487 uV 12:39:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 27.943 uVs 12:39:30 Integrated Voltage Measurement... 12:39:39 Voltage Offset Correction: v_off_ini = 2886.832 uV, v_off_fin = 2902.559 uV 12:39:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -55.395 uVs 12:39:39 Integrated Voltage Measurement... 12:39:48 Voltage Offset Correction: v_off_ini = 2892.569 uV, v_off_fin = 2903.107 uV 12:39:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 46.623 uVs 12:39:48 Integrated Voltage Measurement... 12:39:57 Voltage Offset Correction: v_off_ini = 2888.434 uV, v_off_fin = 2897.940 uV 12:39:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -36.408 uVs 12:39:57 Integrated Voltage Measurement... 12:40:06 Voltage Offset Correction: v_off_ini = 2879.472 uV, v_off_fin = 2884.496 uV 12:40:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 33.565 uVs 12:40:07 Integrated Voltage Measurement... 12:40:15 Voltage Offset Correction: v_off_ini = 2886.219 uV, v_off_fin = 2881.668 uV 12:40:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -57.293 uVs 12:40:18 I2X Average and RMS of Measurements VT = 42.871 +- 1.810 uVs I2X = -3.944 +- 0.167 uTm^2 12:40:23 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 12:40:26 Integrated Voltage Measurement... 12:40:35 Voltage Offset Correction: v_off_ini = 2864.335 uV, v_off_fin = 2876.155 uV 12:40:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.492 uVs 12:40:35 Integrated Voltage Measurement... 12:40:44 Voltage Offset Correction: v_off_ini = 2891.050 uV, v_off_fin = 2893.288 uV 12:40:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.057 uVs 12:40:44 Integrated Voltage Measurement... 12:40:53 Voltage Offset Correction: v_off_ini = 2884.947 uV, v_off_fin = 2881.958 uV 12:40:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.932 uVs 12:40:53 Integrated Voltage Measurement... 12:41:02 Voltage Offset Correction: v_off_ini = 2884.747 uV, v_off_fin = 2857.778 uV 12:41:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 292.397 uVs 12:41:02 Integrated Voltage Measurement... 12:41:11 Voltage Offset Correction: v_off_ini = 2853.216 uV, v_off_fin = 2868.981 uV 12:41:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.518 uVs 12:41:11 Integrated Voltage Measurement... 12:41:20 Voltage Offset Correction: v_off_ini = 2883.631 uV, v_off_fin = 2901.675 uV 12:41:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 277.783 uVs 12:41:22 I2Y Average and RMS of Measurements VT = -285.697 +- 5.120 uVs I2Y = -26.284 +- 0.471 uTm^2 12:41:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:41:34 Integrated Voltage Measurement... 12:41:43 Voltage Offset Correction: v_off_ini = 2879.093 uV, v_off_fin = 2887.831 uV 12:41:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -45.343 uVs 12:41:43 Integrated Voltage Measurement... 12:41:52 Voltage Offset Correction: v_off_ini = 2885.552 uV, v_off_fin = 2881.892 uV 12:41:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.376 uVs 12:41:52 Integrated Voltage Measurement... 12:42:01 Voltage Offset Correction: v_off_ini = 2889.528 uV, v_off_fin = 2872.571 uV 12:42:01 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -39.036 uVs 12:42:01 Integrated Voltage Measurement... 12:42:10 Voltage Offset Correction: v_off_ini = 2887.525 uV, v_off_fin = 2903.974 uV 12:42:10 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 20.900 uVs 12:42:10 Integrated Voltage Measurement... 12:42:19 Voltage Offset Correction: v_off_ini = 2918.935 uV, v_off_fin = 2896.467 uV 12:42:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.845 uVs 12:42:19 Integrated Voltage Measurement... 12:42:28 Voltage Offset Correction: v_off_ini = 2928.150 uV, v_off_fin = 2906.480 uV 12:42:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 9.993 uVs 12:42:32 I1X Average and RMS of Measurements VT = -33.249 +- 11.240 uVs I1X = 6.650 +- 2.248 uTm 12:42:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:42:39 Integrated Voltage Measurement... 12:42:48 Voltage Offset Correction: v_off_ini = 2913.727 uV, v_off_fin = 2897.948 uV 12:42:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -292.171 uVs 12:42:48 Integrated Voltage Measurement... 12:42:57 Voltage Offset Correction: v_off_ini = 2910.704 uV, v_off_fin = 2904.220 uV 12:42:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 274.981 uVs 12:42:57 Integrated Voltage Measurement... 12:43:06 Voltage Offset Correction: v_off_ini = 2892.002 uV, v_off_fin = 2870.228 uV 12:43:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.757 uVs 12:43:06 Integrated Voltage Measurement... 12:43:15 Voltage Offset Correction: v_off_ini = 2896.768 uV, v_off_fin = 2907.471 uV 12:43:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 299.262 uVs 12:43:15 Integrated Voltage Measurement... 12:43:24 Voltage Offset Correction: v_off_ini = 2883.814 uV, v_off_fin = 2872.491 uV 12:43:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -280.123 uVs 12:43:24 Integrated Voltage Measurement... 12:43:33 Voltage Offset Correction: v_off_ini = 2900.693 uV, v_off_fin = 2910.904 uV 12:43:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.476 uVs 12:43:37 I1Y Average and RMS of Measurements VT = -282.795 +- 6.234 uVs I1Y = -56.559 +- 1.247 uTm 12:43:40 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:43:42 Integrated Voltage Measurement... 12:43:51 Voltage Offset Correction: v_off_ini = 2908.348 uV, v_off_fin = 2902.915 uV 12:43:51 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.864 uVs 12:43:51 Integrated Voltage Measurement... 12:44:00 Voltage Offset Correction: v_off_ini = 2904.541 uV, v_off_fin = 2910.660 uV 12:44:00 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 16.084 uVs 12:44:00 Integrated Voltage Measurement... 12:44:09 Voltage Offset Correction: v_off_ini = 2882.215 uV, v_off_fin = 2880.786 uV 12:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.788 uVs 12:44:09 Integrated Voltage Measurement... 12:44:18 Voltage Offset Correction: v_off_ini = 2894.627 uV, v_off_fin = 2901.745 uV 12:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.402 uVs 12:44:18 Integrated Voltage Measurement... 12:44:27 Voltage Offset Correction: v_off_ini = 2900.001 uV, v_off_fin = 2869.738 uV 12:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -29.381 uVs 12:44:27 Integrated Voltage Measurement... 12:44:36 Voltage Offset Correction: v_off_ini = 2889.246 uV, v_off_fin = 2887.850 uV 12:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.307 uVs 12:44:39 I2X Average and RMS of Measurements VT = -24.471 +- 8.778 uVs I2X = 2.251 +- 0.808 uTm^2 12:44:41 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 12:44:44 Integrated Voltage Measurement... 12:44:53 Voltage Offset Correction: v_off_ini = 2880.098 uV, v_off_fin = 2870.710 uV 12:44:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -281.501 uVs 12:44:53 Integrated Voltage Measurement... 12:45:02 Voltage Offset Correction: v_off_ini = 2857.573 uV, v_off_fin = 2885.586 uV 12:45:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 320.321 uVs 12:45:02 Integrated Voltage Measurement... 12:45:11 Voltage Offset Correction: v_off_ini = 2880.692 uV, v_off_fin = 2878.282 uV 12:45:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -300.144 uVs 12:45:11 Integrated Voltage Measurement... 12:45:20 Voltage Offset Correction: v_off_ini = 2869.952 uV, v_off_fin = 2866.384 uV 12:45:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 294.024 uVs 12:45:20 Integrated Voltage Measurement... 12:45:29 Voltage Offset Correction: v_off_ini = 2865.288 uV, v_off_fin = 2867.842 uV 12:45:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -297.008 uVs 12:45:29 Integrated Voltage Measurement... 12:45:38 Voltage Offset Correction: v_off_ini = 2869.341 uV, v_off_fin = 2867.334 uV 12:45:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 275.781 uVs 12:45:40 I2Y Average and RMS of Measurements VT = -294.796 +- 6.143 uVs I2Y = -27.121 +- 0.565 uTm^2 12:45:44 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:45:49 Integrated Voltage Measurement... 12:45:58 Voltage Offset Correction: v_off_ini = 2874.656 uV, v_off_fin = 2875.470 uV 12:45:58 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.855 uVs 12:45:58 Integrated Voltage Measurement... 12:46:07 Voltage Offset Correction: v_off_ini = 2866.896 uV, v_off_fin = 2875.493 uV 12:46:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.842 uVs 12:46:07 Integrated Voltage Measurement... 12:46:16 Voltage Offset Correction: v_off_ini = 2877.545 uV, v_off_fin = 2867.196 uV 12:46:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -34.311 uVs 12:46:16 Integrated Voltage Measurement... 12:46:25 Voltage Offset Correction: v_off_ini = 2905.539 uV, v_off_fin = 2902.100 uV 12:46:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 39.348 uVs 12:46:25 Integrated Voltage Measurement... 12:46:34 Voltage Offset Correction: v_off_ini = 2885.028 uV, v_off_fin = 2890.801 uV 12:46:34 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.236 uVs 12:46:34 Integrated Voltage Measurement... 12:46:43 Voltage Offset Correction: v_off_ini = 2892.620 uV, v_off_fin = 2902.564 uV 12:46:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 10.258 uVs 12:46:47 I1X Average and RMS of Measurements VT = -27.642 +- 7.200 uVs I1X = 5.528 +- 1.440 uTm 12:46:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:46:54 Integrated Voltage Measurement... 12:47:03 Voltage Offset Correction: v_off_ini = 2901.166 uV, v_off_fin = 2880.881 uV 12:47:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.959 uVs 12:47:03 Integrated Voltage Measurement... 12:47:12 Voltage Offset Correction: v_off_ini = 2860.830 uV, v_off_fin = 2874.185 uV 12:47:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 288.882 uVs 12:47:12 Integrated Voltage Measurement... 12:47:21 Voltage Offset Correction: v_off_ini = 2870.143 uV, v_off_fin = 2862.183 uV 12:47:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -258.582 uVs 12:47:21 Integrated Voltage Measurement... 12:47:30 Voltage Offset Correction: v_off_ini = 2897.052 uV, v_off_fin = 2896.394 uV 12:47:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 264.464 uVs 12:47:30 Integrated Voltage Measurement... 12:47:39 Voltage Offset Correction: v_off_ini = 2874.166 uV, v_off_fin = 2862.840 uV 12:47:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -267.547 uVs 12:47:39 Integrated Voltage Measurement... 12:47:48 Voltage Offset Correction: v_off_ini = 2886.556 uV, v_off_fin = 2898.691 uV 12:47:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.880 uVs 12:47:52 I1Y Average and RMS of Measurements VT = -264.886 +- 4.277 uVs I1Y = -52.977 +- 0.855 uTm 12:47:54 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:47:57 Integrated Voltage Measurement... 12:48:06 Voltage Offset Correction: v_off_ini = 2877.182 uV, v_off_fin = 2871.129 uV 12:48:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.607 uVs 12:48:06 Integrated Voltage Measurement... 12:48:15 Voltage Offset Correction: v_off_ini = 2888.501 uV, v_off_fin = 2885.281 uV 12:48:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -7.135 uVs 12:48:15 Integrated Voltage Measurement... 12:48:24 Voltage Offset Correction: v_off_ini = 2866.083 uV, v_off_fin = 2845.892 uV 12:48:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 7.911 uVs 12:48:24 Integrated Voltage Measurement... 12:48:33 Voltage Offset Correction: v_off_ini = 2862.358 uV, v_off_fin = 2865.705 uV 12:48:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.687 uVs 12:48:33 Integrated Voltage Measurement... 12:48:42 Voltage Offset Correction: v_off_ini = 2867.449 uV, v_off_fin = 2853.360 uV 12:48:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.058 uVs 12:48:42 Integrated Voltage Measurement... 12:48:51 Voltage Offset Correction: v_off_ini = 2855.015 uV, v_off_fin = 2862.113 uV 12:48:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.401 uVs 12:48:54 I2X Average and RMS of Measurements VT = -16.451 +- 9.848 uVs I2X = 1.513 +- 0.906 uTm^2 12:48:56 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 12:48:59 Integrated Voltage Measurement... 12:49:08 Voltage Offset Correction: v_off_ini = 2839.551 uV, v_off_fin = 2839.764 uV 12:49:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.287 uVs 12:49:08 Integrated Voltage Measurement... 12:49:17 Voltage Offset Correction: v_off_ini = 2843.162 uV, v_off_fin = 2861.164 uV 12:49:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 300.890 uVs 12:49:17 Integrated Voltage Measurement... 12:49:26 Voltage Offset Correction: v_off_ini = 2849.918 uV, v_off_fin = 2857.469 uV 12:49:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -279.126 uVs 12:49:26 Integrated Voltage Measurement... 12:49:35 Voltage Offset Correction: v_off_ini = 2867.483 uV, v_off_fin = 2846.871 uV 12:49:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.675 uVs 12:49:35 Integrated Voltage Measurement... 12:49:44 Voltage Offset Correction: v_off_ini = 2869.691 uV, v_off_fin = 2870.457 uV 12:49:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -284.789 uVs 12:49:44 Integrated Voltage Measurement... 12:49:53 Voltage Offset Correction: v_off_ini = 2878.278 uV, v_off_fin = 2873.364 uV 12:49:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.531 uVs 12:49:55 I2Y Average and RMS of Measurements VT = -284.050 +- 8.193 uVs I2Y = -26.133 +- 0.754 uTm^2 12:49:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:50:04 Integrated Voltage Measurement... 12:50:13 Voltage Offset Correction: v_off_ini = 2858.087 uV, v_off_fin = 2858.174 uV 12:50:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -50.088 uVs 12:50:13 Integrated Voltage Measurement... 12:50:22 Voltage Offset Correction: v_off_ini = 2857.506 uV, v_off_fin = 2841.211 uV 12:50:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.723 uVs 12:50:22 Integrated Voltage Measurement... 12:50:31 Voltage Offset Correction: v_off_ini = 2841.548 uV, v_off_fin = 2835.510 uV 12:50:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -39.067 uVs 12:50:31 Integrated Voltage Measurement... 12:50:40 Voltage Offset Correction: v_off_ini = 2809.808 uV, v_off_fin = 2823.863 uV 12:50:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 48.023 uVs 12:50:40 Integrated Voltage Measurement... 12:50:49 Voltage Offset Correction: v_off_ini = 2818.671 uV, v_off_fin = 2813.912 uV 12:50:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.875 uVs 12:50:49 Integrated Voltage Measurement... 12:50:58 Voltage Offset Correction: v_off_ini = 2804.876 uV, v_off_fin = 2805.225 uV 12:50:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 53.119 uVs 12:51:02 I1X Average and RMS of Measurements VT = -47.816 +- 3.451 uVs I1X = 9.564 +- 0.690 uTm 12:51:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:51:09 Integrated Voltage Measurement... 12:51:18 Voltage Offset Correction: v_off_ini = 2811.290 uV, v_off_fin = 2785.753 uV 12:51:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -257.245 uVs 12:51:18 Integrated Voltage Measurement... 12:51:27 Voltage Offset Correction: v_off_ini = 2798.528 uV, v_off_fin = 2810.510 uV 12:51:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 277.043 uVs 12:51:27 Integrated Voltage Measurement... 12:51:36 Voltage Offset Correction: v_off_ini = 2803.948 uV, v_off_fin = 2801.742 uV 12:51:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -248.260 uVs 12:51:36 Integrated Voltage Measurement... 12:51:45 Voltage Offset Correction: v_off_ini = 2823.849 uV, v_off_fin = 2824.715 uV 12:51:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.102 uVs 12:51:45 Integrated Voltage Measurement... 12:51:54 Voltage Offset Correction: v_off_ini = 2816.312 uV, v_off_fin = 2807.607 uV 12:51:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.405 uVs 12:51:54 Integrated Voltage Measurement... 12:52:03 Voltage Offset Correction: v_off_ini = 2809.150 uV, v_off_fin = 2792.431 uV 12:52:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.151 uVs 12:52:07 I1Y Average and RMS of Measurements VT = -261.201 +- 4.202 uVs I1Y = -52.240 +- 0.840 uTm 12:52:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:52:12 Integrated Voltage Measurement... 12:52:21 Voltage Offset Correction: v_off_ini = 2783.658 uV, v_off_fin = 2783.368 uV 12:52:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.683 uVs 12:52:21 Integrated Voltage Measurement... 12:52:30 Voltage Offset Correction: v_off_ini = 2788.969 uV, v_off_fin = 2805.483 uV 12:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.622 uVs 12:52:30 Integrated Voltage Measurement... 12:52:39 Voltage Offset Correction: v_off_ini = 2800.309 uV, v_off_fin = 2790.596 uV 12:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.419 uVs 12:52:39 Integrated Voltage Measurement... 12:52:48 Voltage Offset Correction: v_off_ini = 2803.353 uV, v_off_fin = 2808.556 uV 12:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -11.948 uVs 12:52:48 Integrated Voltage Measurement... 12:52:57 Voltage Offset Correction: v_off_ini = 2804.218 uV, v_off_fin = 2795.954 uV 12:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.098 uVs 12:52:57 Integrated Voltage Measurement... 12:53:06 Voltage Offset Correction: v_off_ini = 2813.322 uV, v_off_fin = 2824.418 uV 12:53:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.594 uVs 12:53:08 I2X Average and RMS of Measurements VT = -4.643 +- 9.693 uVs I2X = 0.427 +- 0.892 uTm^2 12:53:11 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 12:53:14 Integrated Voltage Measurement... 12:53:22 Voltage Offset Correction: v_off_ini = 2800.275 uV, v_off_fin = 2820.781 uV 12:53:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.250 uVs 12:53:23 Integrated Voltage Measurement... 12:53:32 Voltage Offset Correction: v_off_ini = 2816.438 uV, v_off_fin = 2819.515 uV 12:53:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 287.076 uVs 12:53:32 Integrated Voltage Measurement... 12:53:41 Voltage Offset Correction: v_off_ini = 2792.449 uV, v_off_fin = 2802.873 uV 12:53:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -252.769 uVs 12:53:41 Integrated Voltage Measurement... 12:53:50 Voltage Offset Correction: v_off_ini = 2801.106 uV, v_off_fin = 2807.890 uV 12:53:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.838 uVs 12:53:50 Integrated Voltage Measurement... 12:53:59 Voltage Offset Correction: v_off_ini = 2818.141 uV, v_off_fin = 2811.415 uV 12:53:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.684 uVs 12:53:59 Integrated Voltage Measurement... 12:54:08 Voltage Offset Correction: v_off_ini = 2815.935 uV, v_off_fin = 2804.849 uV 12:54:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 274.734 uVs 12:54:10 I2Y Average and RMS of Measurements VT = -271.725 +- 9.755 uVs I2Y = -24.999 +- 0.897 uTm^2 12:54:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:54:18 Integrated Voltage Measurement... 12:54:27 Voltage Offset Correction: v_off_ini = 2823.921 uV, v_off_fin = 2809.376 uV 12:54:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.003 uVs 12:54:27 Integrated Voltage Measurement... 12:54:36 Voltage Offset Correction: v_off_ini = 2821.554 uV, v_off_fin = 2805.836 uV 12:54:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.173 uVs 12:54:36 Integrated Voltage Measurement... 12:54:45 Voltage Offset Correction: v_off_ini = 2810.188 uV, v_off_fin = 2799.605 uV 12:54:45 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.639 uVs 12:54:45 Integrated Voltage Measurement... 12:54:54 Voltage Offset Correction: v_off_ini = 2823.357 uV, v_off_fin = 2827.095 uV 12:54:54 Integrated Voltage Measurement dXYus = 0.4998 mm, dXYds = 0.5000 mm dXY = 0.4999 mm VT = 27.312 uVs 12:54:54 Integrated Voltage Measurement... 12:55:03 Voltage Offset Correction: v_off_ini = 2797.526 uV, v_off_fin = 2799.914 uV 12:55:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -40.792 uVs 12:55:03 Integrated Voltage Measurement... 12:55:12 Voltage Offset Correction: v_off_ini = 2772.980 uV, v_off_fin = 2775.932 uV 12:55:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 55.386 uVs 12:55:17 I1X Average and RMS of Measurements VT = -45.718 +- 5.610 uVs I1X = 9.144 +- 1.122 uTm 12:55:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:55:23 Integrated Voltage Measurement... 12:55:32 Voltage Offset Correction: v_off_ini = 2771.800 uV, v_off_fin = 2768.242 uV 12:55:32 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.466 uVs 12:55:32 Integrated Voltage Measurement... 12:55:41 Voltage Offset Correction: v_off_ini = 2784.258 uV, v_off_fin = 2792.968 uV 12:55:41 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.791 uVs 12:55:41 Integrated Voltage Measurement... 12:55:50 Voltage Offset Correction: v_off_ini = 2773.438 uV, v_off_fin = 2770.629 uV 12:55:50 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.498 uVs 12:55:50 Integrated Voltage Measurement... 12:55:59 Voltage Offset Correction: v_off_ini = 2793.216 uV, v_off_fin = 2809.789 uV 12:55:59 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 268.246 uVs 12:55:59 Integrated Voltage Measurement... 12:56:08 Voltage Offset Correction: v_off_ini = 2794.811 uV, v_off_fin = 2766.168 uV 12:56:08 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -243.326 uVs 12:56:08 Integrated Voltage Measurement... 12:56:17 Voltage Offset Correction: v_off_ini = 2786.777 uV, v_off_fin = 2795.092 uV 12:56:17 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.173 uVs 12:56:21 I1Y Average and RMS of Measurements VT = -246.583 +- 10.746 uVs I1Y = -49.317 +- 2.149 uTm 12:56:24 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:56:27 Integrated Voltage Measurement... 12:56:36 Voltage Offset Correction: v_off_ini = 2763.457 uV, v_off_fin = 2760.674 uV 12:56:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.087 uVs 12:56:36 Integrated Voltage Measurement... 12:56:45 Voltage Offset Correction: v_off_ini = 2790.594 uV, v_off_fin = 2772.990 uV 12:56:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.221 uVs 12:56:45 Integrated Voltage Measurement... 12:56:54 Voltage Offset Correction: v_off_ini = 2775.676 uV, v_off_fin = 2774.818 uV 12:56:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -4.701 uVs 12:56:54 Integrated Voltage Measurement... 12:57:03 Voltage Offset Correction: v_off_ini = 2784.460 uV, v_off_fin = 2788.371 uV 12:57:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 3.235 uVs 12:57:03 Integrated Voltage Measurement... 12:57:12 Voltage Offset Correction: v_off_ini = 2748.636 uV, v_off_fin = 2737.823 uV 12:57:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.401 uVs 12:57:12 Integrated Voltage Measurement... 12:57:21 Voltage Offset Correction: v_off_ini = 2760.115 uV, v_off_fin = 2760.760 uV 12:57:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.450 uVs 12:57:23 I2X Average and RMS of Measurements VT = -4.682 +- 2.410 uVs I2X = 0.431 +- 0.222 uTm^2 12:57:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 12:57:28 Integrated Voltage Measurement... 12:57:37 Voltage Offset Correction: v_off_ini = 2773.865 uV, v_off_fin = 2774.581 uV 12:57:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -283.960 uVs 12:57:37 Integrated Voltage Measurement... 12:57:46 Voltage Offset Correction: v_off_ini = 2756.842 uV, v_off_fin = 2754.477 uV 12:57:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.579 uVs 12:57:46 Integrated Voltage Measurement... 12:57:55 Voltage Offset Correction: v_off_ini = 2757.779 uV, v_off_fin = 2761.360 uV 12:57:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.867 uVs 12:57:55 Integrated Voltage Measurement... 12:58:04 Voltage Offset Correction: v_off_ini = 2762.653 uV, v_off_fin = 2759.109 uV 12:58:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.522 uVs 12:58:04 Integrated Voltage Measurement... 12:58:13 Voltage Offset Correction: v_off_ini = 2765.839 uV, v_off_fin = 2748.258 uV 12:58:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -255.729 uVs 12:58:13 Integrated Voltage Measurement... 12:58:22 Voltage Offset Correction: v_off_ini = 2742.104 uV, v_off_fin = 2735.752 uV 12:58:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 254.754 uVs 12:58:25 I2Y Average and RMS of Measurements VT = -261.902 +- 8.413 uVs I2Y = -24.095 +- 0.774 uTm^2 12:58:29 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:58:33 Integrated Voltage Measurement... 12:58:42 Voltage Offset Correction: v_off_ini = 2776.975 uV, v_off_fin = 2756.809 uV 12:58:42 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.346 uVs 12:58:42 Integrated Voltage Measurement... 12:58:51 Voltage Offset Correction: v_off_ini = 2760.367 uV, v_off_fin = 2745.699 uV 12:58:51 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.419 uVs 12:58:51 Integrated Voltage Measurement... 12:59:00 Voltage Offset Correction: v_off_ini = 2766.578 uV, v_off_fin = 2761.162 uV 12:59:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.098 uVs 12:59:00 Integrated Voltage Measurement... 12:59:09 Voltage Offset Correction: v_off_ini = 2759.507 uV, v_off_fin = 2753.767 uV 12:59:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 6.380 uVs 12:59:09 Integrated Voltage Measurement... 12:59:18 Voltage Offset Correction: v_off_ini = 2734.228 uV, v_off_fin = 2740.464 uV 12:59:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -33.004 uVs 12:59:18 Integrated Voltage Measurement... 12:59:27 Voltage Offset Correction: v_off_ini = 2735.750 uV, v_off_fin = 2743.550 uV 12:59:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.542 uVs 12:59:31 I1X Average and RMS of Measurements VT = -30.465 +- 11.605 uVs I1X = 6.093 +- 2.321 uTm 12:59:34 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 12:59:38 Integrated Voltage Measurement... 12:59:47 Voltage Offset Correction: v_off_ini = 2738.333 uV, v_off_fin = 2736.537 uV 12:59:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.625 uVs 12:59:47 Integrated Voltage Measurement... 12:59:56 Voltage Offset Correction: v_off_ini = 2732.061 uV, v_off_fin = 2735.464 uV 12:59:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 231.922 uVs 12:59:56 Integrated Voltage Measurement... 13:00:05 Voltage Offset Correction: v_off_ini = 2721.827 uV, v_off_fin = 2704.229 uV 13:00:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.458 uVs 13:00:05 Integrated Voltage Measurement... 13:00:14 Voltage Offset Correction: v_off_ini = 2727.725 uV, v_off_fin = 2733.596 uV 13:00:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 249.448 uVs 13:00:14 Integrated Voltage Measurement... 13:00:23 Voltage Offset Correction: v_off_ini = 2720.215 uV, v_off_fin = 2712.020 uV 13:00:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.457 uVs 13:00:23 Integrated Voltage Measurement... 13:00:32 Voltage Offset Correction: v_off_ini = 2711.899 uV, v_off_fin = 2732.579 uV 13:00:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 224.419 uVs 13:00:36 I1Y Average and RMS of Measurements VT = -234.388 +- 12.925 uVs I1Y = -46.878 +- 2.585 uTm 13:00:39 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:00:41 Integrated Voltage Measurement... 13:00:50 Voltage Offset Correction: v_off_ini = 2725.394 uV, v_off_fin = 2722.807 uV 13:00:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.291 uVs 13:00:50 Integrated Voltage Measurement... 13:00:59 Voltage Offset Correction: v_off_ini = 2727.118 uV, v_off_fin = 2735.249 uV 13:00:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 14.592 uVs 13:00:59 Integrated Voltage Measurement... 13:01:08 Voltage Offset Correction: v_off_ini = 2733.328 uV, v_off_fin = 2708.574 uV 13:01:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -11.401 uVs 13:01:08 Integrated Voltage Measurement... 13:01:17 Voltage Offset Correction: v_off_ini = 2736.852 uV, v_off_fin = 2736.836 uV 13:01:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.645 uVs 13:01:17 Integrated Voltage Measurement... 13:01:26 Voltage Offset Correction: v_off_ini = 2703.436 uV, v_off_fin = 2713.560 uV 13:01:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 9.583 uVs 13:01:26 Integrated Voltage Measurement... 13:01:35 Voltage Offset Correction: v_off_ini = 2731.925 uV, v_off_fin = 2730.749 uV 13:01:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -23.826 uVs 13:01:38 I2X Average and RMS of Measurements VT = 0.462 +- 12.418 uVs I2X = -0.042 +- 1.142 uTm^2 13:01:40 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:01:43 Integrated Voltage Measurement... 13:01:52 Voltage Offset Correction: v_off_ini = 2722.501 uV, v_off_fin = 2700.509 uV 13:01:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -219.862 uVs 13:01:52 Integrated Voltage Measurement... 13:02:01 Voltage Offset Correction: v_off_ini = 2732.659 uV, v_off_fin = 2714.068 uV 13:02:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 271.186 uVs 13:02:01 Integrated Voltage Measurement... 13:02:10 Voltage Offset Correction: v_off_ini = 2721.695 uV, v_off_fin = 2725.311 uV 13:02:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.337 uVs 13:02:10 Integrated Voltage Measurement... 13:02:19 Voltage Offset Correction: v_off_ini = 2707.065 uV, v_off_fin = 2711.926 uV 13:02:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 258.850 uVs 13:02:19 Integrated Voltage Measurement... 13:02:28 Voltage Offset Correction: v_off_ini = 2727.101 uV, v_off_fin = 2725.201 uV 13:02:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.934 uVs 13:02:28 Integrated Voltage Measurement... 13:02:37 Voltage Offset Correction: v_off_ini = 2703.881 uV, v_off_fin = 2711.371 uV 13:02:37 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 257.606 uVs 13:02:40 I2Y Average and RMS of Measurements VT = -248.629 +- 2.694 uVs I2Y = -22.874 +- 0.248 uTm^2 13:03:03 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:03:08 Integrated Voltage Measurement... 13:03:16 Voltage Offset Correction: v_off_ini = 2687.094 uV, v_off_fin = 2677.986 uV 13:03:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -69.653 uVs 13:03:17 Integrated Voltage Measurement... 13:03:25 Voltage Offset Correction: v_off_ini = 2662.214 uV, v_off_fin = 2655.756 uV 13:03:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 84.350 uVs 13:03:26 Integrated Voltage Measurement... 13:03:34 Voltage Offset Correction: v_off_ini = 2672.663 uV, v_off_fin = 2674.532 uV 13:03:35 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.501 uVs 13:03:35 Integrated Voltage Measurement... 13:03:43 Voltage Offset Correction: v_off_ini = 2664.035 uV, v_off_fin = 2665.629 uV 13:03:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 106.737 uVs 13:03:44 Integrated Voltage Measurement... 13:03:52 Voltage Offset Correction: v_off_ini = 2664.012 uV, v_off_fin = 2642.098 uV 13:03:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.167 uVs 13:03:53 Integrated Voltage Measurement... 13:04:01 Voltage Offset Correction: v_off_ini = 2646.962 uV, v_off_fin = 2643.694 uV 13:04:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 82.481 uVs 13:04:06 I1X Average and RMS of Measurements VT = -79.482 +- 7.871 uVs I1X = 15.897 +- 1.574 uTm 13:04:08 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:04:12 Integrated Voltage Measurement... 13:04:21 Voltage Offset Correction: v_off_ini = 2658.875 uV, v_off_fin = 2654.576 uV 13:04:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.432 uVs 13:04:21 Integrated Voltage Measurement... 13:04:30 Voltage Offset Correction: v_off_ini = 2678.121 uV, v_off_fin = 2673.343 uV 13:04:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.582 uVs 13:04:30 Integrated Voltage Measurement... 13:04:39 Voltage Offset Correction: v_off_ini = 2664.111 uV, v_off_fin = 2645.584 uV 13:04:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -211.369 uVs 13:04:39 Integrated Voltage Measurement... 13:04:48 Voltage Offset Correction: v_off_ini = 2667.877 uV, v_off_fin = 2664.236 uV 13:04:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.695 uVs 13:04:48 Integrated Voltage Measurement... 13:04:57 Voltage Offset Correction: v_off_ini = 2658.801 uV, v_off_fin = 2641.994 uV 13:04:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -230.837 uVs 13:04:57 Integrated Voltage Measurement... 13:05:06 Voltage Offset Correction: v_off_ini = 2665.456 uV, v_off_fin = 2694.191 uV 13:05:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 222.084 uVs 13:05:11 I1Y Average and RMS of Measurements VT = -218.166 +- 5.989 uVs I1Y = -43.633 +- 1.198 uTm 13:05:16 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:05:18 Integrated Voltage Measurement... 13:05:27 Voltage Offset Correction: v_off_ini = 2636.891 uV, v_off_fin = 2639.628 uV 13:05:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.614 uVs 13:05:27 Integrated Voltage Measurement... 13:05:36 Voltage Offset Correction: v_off_ini = 2648.412 uV, v_off_fin = 2669.687 uV 13:05:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 69.191 uVs 13:05:36 Integrated Voltage Measurement... 13:05:45 Voltage Offset Correction: v_off_ini = 2655.351 uV, v_off_fin = 2662.823 uV 13:05:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -66.453 uVs 13:05:45 Integrated Voltage Measurement... 13:05:54 Voltage Offset Correction: v_off_ini = 2663.535 uV, v_off_fin = 2670.165 uV 13:05:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 29.764 uVs 13:05:54 Integrated Voltage Measurement... 13:06:03 Voltage Offset Correction: v_off_ini = 2643.015 uV, v_off_fin = 2646.118 uV 13:06:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.948 uVs 13:06:03 Integrated Voltage Measurement... 13:06:12 Voltage Offset Correction: v_off_ini = 2629.997 uV, v_off_fin = 2631.952 uV 13:06:12 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 49.673 uVs 13:06:15 I2X Average and RMS of Measurements VT = -49.274 +- 10.684 uVs I2X = 4.533 +- 0.983 uTm^2 13:06:20 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:06:22 Integrated Voltage Measurement... 13:06:31 Voltage Offset Correction: v_off_ini = 2631.637 uV, v_off_fin = 2623.839 uV 13:06:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.639 uVs 13:06:32 Integrated Voltage Measurement... 13:06:40 Voltage Offset Correction: v_off_ini = 2630.022 uV, v_off_fin = 2613.388 uV 13:06:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 229.204 uVs 13:06:41 Integrated Voltage Measurement... 13:06:50 Voltage Offset Correction: v_off_ini = 2617.491 uV, v_off_fin = 2630.556 uV 13:06:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.327 uVs 13:06:50 Integrated Voltage Measurement... 13:06:59 Voltage Offset Correction: v_off_ini = 2627.909 uV, v_off_fin = 2637.927 uV 13:06:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.267 uVs 13:06:59 Integrated Voltage Measurement... 13:07:08 Voltage Offset Correction: v_off_ini = 2637.630 uV, v_off_fin = 2633.461 uV 13:07:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -271.114 uVs 13:07:08 Integrated Voltage Measurement... 13:07:17 Voltage Offset Correction: v_off_ini = 2634.525 uV, v_off_fin = 2620.553 uV 13:07:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.418 uVs 13:07:19 I2Y Average and RMS of Measurements VT = -254.328 +- 13.188 uVs I2Y = -23.398 +- 1.213 uTm^2 13:07:24 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:07:28 Integrated Voltage Measurement... 13:07:37 Voltage Offset Correction: v_off_ini = 2590.955 uV, v_off_fin = 2603.666 uV 13:07:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.073 uVs 13:07:37 Integrated Voltage Measurement... 13:07:46 Voltage Offset Correction: v_off_ini = 2635.717 uV, v_off_fin = 2630.960 uV 13:07:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 66.458 uVs 13:07:46 Integrated Voltage Measurement... 13:07:55 Voltage Offset Correction: v_off_ini = 2609.467 uV, v_off_fin = 2599.539 uV 13:07:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -57.261 uVs 13:07:55 Integrated Voltage Measurement... 13:08:04 Voltage Offset Correction: v_off_ini = 2611.388 uV, v_off_fin = 2591.117 uV 13:08:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.230 uVs 13:08:04 Integrated Voltage Measurement... 13:08:13 Voltage Offset Correction: v_off_ini = 2578.663 uV, v_off_fin = 2562.960 uV 13:08:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -63.603 uVs 13:08:13 Integrated Voltage Measurement... 13:08:22 Voltage Offset Correction: v_off_ini = 2577.712 uV, v_off_fin = 2588.369 uV 13:08:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 86.306 uVs 13:08:26 I1X Average and RMS of Measurements VT = -63.322 +- 9.272 uVs I1X = 12.664 +- 1.854 uTm 13:08:29 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:08:33 Integrated Voltage Measurement... 13:08:42 Voltage Offset Correction: v_off_ini = 2603.101 uV, v_off_fin = 2593.649 uV 13:08:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.858 uVs 13:08:42 Integrated Voltage Measurement... 13:08:51 Voltage Offset Correction: v_off_ini = 2584.474 uV, v_off_fin = 2605.329 uV 13:08:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 250.299 uVs 13:08:51 Integrated Voltage Measurement... 13:09:00 Voltage Offset Correction: v_off_ini = 2613.785 uV, v_off_fin = 2600.787 uV 13:09:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.826 uVs 13:09:00 Integrated Voltage Measurement... 13:09:09 Voltage Offset Correction: v_off_ini = 2589.899 uV, v_off_fin = 2589.706 uV 13:09:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 240.464 uVs 13:09:09 Integrated Voltage Measurement... 13:09:18 Voltage Offset Correction: v_off_ini = 2604.663 uV, v_off_fin = 2583.084 uV 13:09:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.539 uVs 13:09:18 Integrated Voltage Measurement... 13:09:27 Voltage Offset Correction: v_off_ini = 2594.090 uV, v_off_fin = 2602.204 uV 13:09:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 229.355 uVs 13:09:31 I1Y Average and RMS of Measurements VT = -235.057 +- 2.096 uVs I1Y = -47.011 +- 0.419 uTm 13:09:36 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:09:39 Integrated Voltage Measurement... 13:09:48 Voltage Offset Correction: v_off_ini = 2594.973 uV, v_off_fin = 2587.292 uV 13:09:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -22.188 uVs 13:09:48 Integrated Voltage Measurement... 13:09:57 Voltage Offset Correction: v_off_ini = 2583.386 uV, v_off_fin = 2605.543 uV 13:09:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 40.921 uVs 13:09:57 Integrated Voltage Measurement... 13:10:06 Voltage Offset Correction: v_off_ini = 2590.312 uV, v_off_fin = 2597.302 uV 13:10:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -23.247 uVs 13:10:06 Integrated Voltage Measurement... 13:10:15 Voltage Offset Correction: v_off_ini = 2617.569 uV, v_off_fin = 2607.665 uV 13:10:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.821 uVs 13:10:15 Integrated Voltage Measurement... 13:10:24 Voltage Offset Correction: v_off_ini = 2594.103 uV, v_off_fin = 2584.187 uV 13:10:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.491 uVs 13:10:24 Integrated Voltage Measurement... 13:10:33 Voltage Offset Correction: v_off_ini = 2594.418 uV, v_off_fin = 2596.442 uV 13:10:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 63.881 uVs 13:10:35 I2X Average and RMS of Measurements VT = -36.925 +- 9.808 uVs I2X = 3.397 +- 0.902 uTm^2 13:10:40 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:10:43 Integrated Voltage Measurement... 13:10:52 Voltage Offset Correction: v_off_ini = 2587.765 uV, v_off_fin = 2596.988 uV 13:10:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -216.812 uVs 13:10:52 Integrated Voltage Measurement... 13:11:01 Voltage Offset Correction: v_off_ini = 2571.128 uV, v_off_fin = 2601.401 uV 13:11:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 240.286 uVs 13:11:01 Integrated Voltage Measurement... 13:11:10 Voltage Offset Correction: v_off_ini = 2607.459 uV, v_off_fin = 2576.279 uV 13:11:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -234.399 uVs 13:11:10 Integrated Voltage Measurement... 13:11:19 Voltage Offset Correction: v_off_ini = 2605.070 uV, v_off_fin = 2606.766 uV 13:11:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.492 uVs 13:11:19 Integrated Voltage Measurement... 13:11:28 Voltage Offset Correction: v_off_ini = 2600.532 uV, v_off_fin = 2615.828 uV 13:11:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.486 uVs 13:11:28 Integrated Voltage Measurement... 13:11:37 Voltage Offset Correction: v_off_ini = 2617.687 uV, v_off_fin = 2606.787 uV 13:11:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.296 uVs 13:11:39 I2Y Average and RMS of Measurements VT = -238.629 +- 7.748 uVs I2Y = -21.954 +- 0.713 uTm^2 13:11:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:11:48 Integrated Voltage Measurement... 13:11:57 Voltage Offset Correction: v_off_ini = 2584.429 uV, v_off_fin = 2589.778 uV 13:11:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -32.534 uVs 13:11:57 Integrated Voltage Measurement... 13:12:06 Voltage Offset Correction: v_off_ini = 2600.163 uV, v_off_fin = 2582.025 uV 13:12:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 18.565 uVs 13:12:06 Integrated Voltage Measurement... 13:12:15 Voltage Offset Correction: v_off_ini = 2617.598 uV, v_off_fin = 2597.871 uV 13:12:15 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -19.291 uVs 13:12:15 Integrated Voltage Measurement... 13:12:24 Voltage Offset Correction: v_off_ini = 2600.008 uV, v_off_fin = 2613.921 uV 13:12:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.652 uVs 13:12:24 Integrated Voltage Measurement... 13:12:33 Voltage Offset Correction: v_off_ini = 2616.290 uV, v_off_fin = 2592.761 uV 13:12:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -56.594 uVs 13:12:33 Integrated Voltage Measurement... 13:12:42 Voltage Offset Correction: v_off_ini = 2606.100 uV, v_off_fin = 2604.104 uV 13:12:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 31.491 uVs 13:12:47 I1X Average and RMS of Measurements VT = -32.688 +- 8.117 uVs I1X = 6.538 +- 1.623 uTm 13:12:49 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:12:53 Integrated Voltage Measurement... 13:13:02 Voltage Offset Correction: v_off_ini = 2585.396 uV, v_off_fin = 2584.731 uV 13:13:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -239.226 uVs 13:13:02 Integrated Voltage Measurement... 13:13:11 Voltage Offset Correction: v_off_ini = 2615.161 uV, v_off_fin = 2624.183 uV 13:13:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 245.728 uVs 13:13:11 Integrated Voltage Measurement... 13:13:20 Voltage Offset Correction: v_off_ini = 2595.462 uV, v_off_fin = 2582.493 uV 13:13:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -224.694 uVs 13:13:20 Integrated Voltage Measurement... 13:13:29 Voltage Offset Correction: v_off_ini = 2591.427 uV, v_off_fin = 2586.962 uV 13:13:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 239.287 uVs 13:13:29 Integrated Voltage Measurement... 13:13:38 Voltage Offset Correction: v_off_ini = 2577.043 uV, v_off_fin = 2561.657 uV 13:13:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.475 uVs 13:13:38 Integrated Voltage Measurement... 13:13:47 Voltage Offset Correction: v_off_ini = 2599.446 uV, v_off_fin = 2600.842 uV 13:13:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.506 uVs 13:13:51 I1Y Average and RMS of Measurements VT = -239.319 +- 5.199 uVs I1Y = -47.864 +- 1.040 uTm 13:13:57 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:13:59 Integrated Voltage Measurement... 13:14:08 Voltage Offset Correction: v_off_ini = 2574.662 uV, v_off_fin = 2565.397 uV 13:14:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.641 uVs 13:14:08 Integrated Voltage Measurement... 13:14:17 Voltage Offset Correction: v_off_ini = 2583.432 uV, v_off_fin = 2602.524 uV 13:14:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 26.798 uVs 13:14:17 Integrated Voltage Measurement... 13:14:26 Voltage Offset Correction: v_off_ini = 2592.676 uV, v_off_fin = 2580.009 uV 13:14:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -16.291 uVs 13:14:26 Integrated Voltage Measurement... 13:14:35 Voltage Offset Correction: v_off_ini = 2581.536 uV, v_off_fin = 2587.444 uV 13:14:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.102 uVs 13:14:35 Integrated Voltage Measurement... 13:14:44 Voltage Offset Correction: v_off_ini = 2587.163 uV, v_off_fin = 2586.164 uV 13:14:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.703 uVs 13:14:44 Integrated Voltage Measurement... 13:14:53 Voltage Offset Correction: v_off_ini = 2579.896 uV, v_off_fin = 2582.143 uV 13:14:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 1.210 uVs 13:14:56 I2X Average and RMS of Measurements VT = -6.189 +- 6.328 uVs I2X = 0.569 +- 0.582 uTm^2 13:15:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:15:03 Integrated Voltage Measurement... 13:15:12 Voltage Offset Correction: v_off_ini = 2587.946 uV, v_off_fin = 2592.914 uV 13:15:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.523 uVs 13:15:12 Integrated Voltage Measurement... 13:15:21 Voltage Offset Correction: v_off_ini = 2585.810 uV, v_off_fin = 2590.661 uV 13:15:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 267.188 uVs 13:15:21 Integrated Voltage Measurement... 13:15:30 Voltage Offset Correction: v_off_ini = 2611.856 uV, v_off_fin = 2595.420 uV 13:15:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.158 uVs 13:15:30 Integrated Voltage Measurement... 13:15:39 Voltage Offset Correction: v_off_ini = 2616.483 uV, v_off_fin = 2629.361 uV 13:15:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.077 uVs 13:15:39 Integrated Voltage Measurement... 13:15:48 Voltage Offset Correction: v_off_ini = 2605.993 uV, v_off_fin = 2593.268 uV 13:15:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.859 uVs 13:15:48 Integrated Voltage Measurement... 13:15:57 Voltage Offset Correction: v_off_ini = 2584.690 uV, v_off_fin = 2583.145 uV 13:15:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.533 uVs 13:16:00 I2Y Average and RMS of Measurements VT = -251.223 +- 8.236 uVs I2Y = -23.113 +- 0.758 uTm^2 13:16:04 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:16:09 Integrated Voltage Measurement... 13:16:18 Voltage Offset Correction: v_off_ini = 2584.161 uV, v_off_fin = 2572.256 uV 13:16:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -19.267 uVs 13:16:18 Integrated Voltage Measurement... 13:16:27 Voltage Offset Correction: v_off_ini = 2612.130 uV, v_off_fin = 2624.614 uV 13:16:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -21.826 uVs 13:16:27 Integrated Voltage Measurement... 13:16:36 Voltage Offset Correction: v_off_ini = 2605.271 uV, v_off_fin = 2603.482 uV 13:16:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.251 uVs 13:16:36 Integrated Voltage Measurement... 13:16:45 Voltage Offset Correction: v_off_ini = 2565.963 uV, v_off_fin = 2582.918 uV 13:16:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -5.124 uVs 13:16:45 Integrated Voltage Measurement... 13:16:54 Voltage Offset Correction: v_off_ini = 2589.622 uV, v_off_fin = 2604.239 uV 13:16:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -3.309 uVs 13:16:54 Integrated Voltage Measurement... 13:17:03 Voltage Offset Correction: v_off_ini = 2603.593 uV, v_off_fin = 2594.869 uV 13:17:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 7.823 uVs 13:17:07 I1X Average and RMS of Measurements VT = -5.950 +- 6.066 uVs I1X = 1.190 +- 1.213 uTm 13:17:09 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:17:14 Integrated Voltage Measurement... 13:17:23 Voltage Offset Correction: v_off_ini = 2607.803 uV, v_off_fin = 2595.837 uV 13:17:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.015 uVs 13:17:23 Integrated Voltage Measurement... 13:17:32 Voltage Offset Correction: v_off_ini = 2600.746 uV, v_off_fin = 2618.988 uV 13:17:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.216 uVs 13:17:32 Integrated Voltage Measurement... 13:17:41 Voltage Offset Correction: v_off_ini = 2609.663 uV, v_off_fin = 2596.061 uV 13:17:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -241.048 uVs 13:17:41 Integrated Voltage Measurement... 13:17:50 Voltage Offset Correction: v_off_ini = 2604.884 uV, v_off_fin = 2629.637 uV 13:17:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 256.945 uVs 13:17:50 Integrated Voltage Measurement... 13:17:59 Voltage Offset Correction: v_off_ini = 2616.905 uV, v_off_fin = 2594.151 uV 13:17:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.851 uVs 13:17:59 Integrated Voltage Measurement... 13:18:08 Voltage Offset Correction: v_off_ini = 2601.737 uV, v_off_fin = 2608.662 uV 13:18:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 236.995 uVs 13:18:12 I1Y Average and RMS of Measurements VT = -250.178 +- 1.381 uVs I1Y = -50.036 +- 0.276 uTm 13:18:17 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:18:19 Integrated Voltage Measurement... 13:18:28 Voltage Offset Correction: v_off_ini = 2586.308 uV, v_off_fin = 2582.564 uV 13:18:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 36.813 uVs 13:18:28 Integrated Voltage Measurement... 13:18:37 Voltage Offset Correction: v_off_ini = 2579.215 uV, v_off_fin = 2615.707 uV 13:18:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -6.662 uVs 13:18:38 Integrated Voltage Measurement... 13:18:46 Voltage Offset Correction: v_off_ini = 2609.754 uV, v_off_fin = 2582.626 uV 13:18:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 6.989 uVs 13:18:47 Integrated Voltage Measurement... 13:18:56 Voltage Offset Correction: v_off_ini = 2599.293 uV, v_off_fin = 2589.195 uV 13:18:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -15.935 uVs 13:18:56 Integrated Voltage Measurement... 13:19:05 Voltage Offset Correction: v_off_ini = 2580.798 uV, v_off_fin = 2583.442 uV 13:19:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 27.547 uVs 13:19:05 Integrated Voltage Measurement... 13:19:14 Voltage Offset Correction: v_off_ini = 2581.450 uV, v_off_fin = 2609.976 uV 13:19:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -13.388 uVs 13:19:16 I2X Average and RMS of Measurements VT = 17.889 +- 4.574 uVs I2X = -1.646 +- 0.421 uTm^2 13:19:21 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:19:24 Integrated Voltage Measurement... 13:19:33 Voltage Offset Correction: v_off_ini = 2585.375 uV, v_off_fin = 2600.652 uV 13:19:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -259.915 uVs 13:19:33 Integrated Voltage Measurement... 13:19:42 Voltage Offset Correction: v_off_ini = 2606.866 uV, v_off_fin = 2603.587 uV 13:19:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.309 uVs 13:19:42 Integrated Voltage Measurement... 13:19:51 Voltage Offset Correction: v_off_ini = 2572.079 uV, v_off_fin = 2605.775 uV 13:19:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.693 uVs 13:19:51 Integrated Voltage Measurement... 13:20:00 Voltage Offset Correction: v_off_ini = 2605.275 uV, v_off_fin = 2604.663 uV 13:20:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.928 uVs 13:20:00 Integrated Voltage Measurement... 13:20:09 Voltage Offset Correction: v_off_ini = 2595.921 uV, v_off_fin = 2590.208 uV 13:20:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -260.089 uVs 13:20:09 Integrated Voltage Measurement... 13:20:18 Voltage Offset Correction: v_off_ini = 2598.861 uV, v_off_fin = 2584.964 uV 13:20:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 227.929 uVs 13:20:20 I2Y Average and RMS of Measurements VT = -251.810 +- 6.370 uVs I2Y = -23.167 +- 0.586 uTm^2 13:20:25 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:20:29 Integrated Voltage Measurement... 13:20:38 Voltage Offset Correction: v_off_ini = 2588.749 uV, v_off_fin = 2592.166 uV 13:20:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -4.055 uVs 13:20:38 Integrated Voltage Measurement... 13:20:47 Voltage Offset Correction: v_off_ini = 2604.857 uV, v_off_fin = 2581.189 uV 13:20:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -24.566 uVs 13:20:47 Integrated Voltage Measurement... 13:20:56 Voltage Offset Correction: v_off_ini = 2569.594 uV, v_off_fin = 2550.664 uV 13:20:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 5.406 uVs 13:20:56 Integrated Voltage Measurement... 13:21:05 Voltage Offset Correction: v_off_ini = 2550.095 uV, v_off_fin = 2585.555 uV 13:21:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -10.054 uVs 13:21:05 Integrated Voltage Measurement... 13:21:14 Voltage Offset Correction: v_off_ini = 2584.933 uV, v_off_fin = 2580.263 uV 13:21:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 19.177 uVs 13:21:14 Integrated Voltage Measurement... 13:21:23 Voltage Offset Correction: v_off_ini = 2588.500 uV, v_off_fin = 2585.212 uV 13:21:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 9.203 uVs 13:21:27 I1X Average and RMS of Measurements VT = 7.658 +- 2.152 uVs I1X = -1.532 +- 0.430 uTm 13:21:30 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:21:34 Integrated Voltage Measurement... 13:21:43 Voltage Offset Correction: v_off_ini = 2574.633 uV, v_off_fin = 2574.150 uV 13:21:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -250.799 uVs 13:21:43 Integrated Voltage Measurement... 13:21:52 Voltage Offset Correction: v_off_ini = 2586.745 uV, v_off_fin = 2585.787 uV 13:21:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 269.605 uVs 13:21:52 Integrated Voltage Measurement... 13:22:01 Voltage Offset Correction: v_off_ini = 2578.168 uV, v_off_fin = 2563.327 uV 13:22:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.245 uVs 13:22:01 Integrated Voltage Measurement... 13:22:10 Voltage Offset Correction: v_off_ini = 2570.467 uV, v_off_fin = 2568.363 uV 13:22:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 254.162 uVs 13:22:10 Integrated Voltage Measurement... 13:22:19 Voltage Offset Correction: v_off_ini = 2556.040 uV, v_off_fin = 2565.961 uV 13:22:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -264.081 uVs 13:22:19 Integrated Voltage Measurement... 13:22:28 Voltage Offset Correction: v_off_ini = 2547.092 uV, v_off_fin = 2551.036 uV 13:22:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 262.808 uVs 13:22:32 I1Y Average and RMS of Measurements VT = -261.116 +- 1.659 uVs I1Y = -52.223 +- 0.332 uTm 13:22:37 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:22:40 Integrated Voltage Measurement... 13:22:49 Voltage Offset Correction: v_off_ini = 2514.239 uV, v_off_fin = 2532.980 uV 13:22:49 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 40.670 uVs 13:22:49 Integrated Voltage Measurement... 13:22:58 Voltage Offset Correction: v_off_ini = 2540.342 uV, v_off_fin = 2555.272 uV 13:22:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -27.532 uVs 13:22:58 Integrated Voltage Measurement... 13:23:07 Voltage Offset Correction: v_off_ini = 2539.415 uV, v_off_fin = 2526.075 uV 13:23:07 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 46.659 uVs 13:23:07 Integrated Voltage Measurement... 13:23:16 Voltage Offset Correction: v_off_ini = 2548.905 uV, v_off_fin = 2548.414 uV 13:23:16 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -43.472 uVs 13:23:16 Integrated Voltage Measurement... 13:23:25 Voltage Offset Correction: v_off_ini = 2545.607 uV, v_off_fin = 2525.907 uV 13:23:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 34.578 uVs 13:23:25 Integrated Voltage Measurement... 13:23:34 Voltage Offset Correction: v_off_ini = 2544.480 uV, v_off_fin = 2533.215 uV 13:23:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -20.629 uVs 13:23:36 I2X Average and RMS of Measurements VT = 35.590 +- 7.206 uVs I2X = -3.274 +- 0.663 uTm^2 13:23:42 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 13:23:44 Integrated Voltage Measurement... 13:23:53 Voltage Offset Correction: v_off_ini = 2527.129 uV, v_off_fin = 2503.358 uV 13:23:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.902 uVs 13:23:53 Integrated Voltage Measurement... 13:24:02 Voltage Offset Correction: v_off_ini = 2540.894 uV, v_off_fin = 2528.872 uV 13:24:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.049 uVs 13:24:02 Integrated Voltage Measurement... 13:24:11 Voltage Offset Correction: v_off_ini = 2520.204 uV, v_off_fin = 2512.402 uV 13:24:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.419 uVs 13:24:11 Integrated Voltage Measurement... 13:24:20 Voltage Offset Correction: v_off_ini = 2524.690 uV, v_off_fin = 2527.286 uV 13:24:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.334 uVs 13:24:20 Integrated Voltage Measurement... 13:24:29 Voltage Offset Correction: v_off_ini = 2530.720 uV, v_off_fin = 2531.098 uV 13:24:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -282.372 uVs 13:24:29 Integrated Voltage Measurement... 13:24:38 Voltage Offset Correction: v_off_ini = 2507.847 uV, v_off_fin = 2499.876 uV 13:24:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 265.601 uVs 13:24:41 I2Y Average and RMS of Measurements VT = -273.113 +- 5.181 uVs I2Y = -25.126 +- 0.477 uTm^2 13:24:48 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:24:53 Integrated Voltage Measurement... 13:25:02 Voltage Offset Correction: v_off_ini = 2541.723 uV, v_off_fin = 2538.183 uV 13:25:02 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -41.721 uVs 13:25:02 Integrated Voltage Measurement... 13:25:11 Voltage Offset Correction: v_off_ini = 2528.020 uV, v_off_fin = 2513.101 uV 13:25:11 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.871 uVs 13:25:11 Integrated Voltage Measurement... 13:25:20 Voltage Offset Correction: v_off_ini = 2515.123 uV, v_off_fin = 2485.726 uV 13:25:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -33.796 uVs 13:25:20 Integrated Voltage Measurement... 13:25:29 Voltage Offset Correction: v_off_ini = 2493.389 uV, v_off_fin = 2496.355 uV 13:25:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.135 uVs 13:25:29 Integrated Voltage Measurement... 13:25:38 Voltage Offset Correction: v_off_ini = 2492.289 uV, v_off_fin = 2508.056 uV 13:25:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -40.994 uVs 13:25:38 Integrated Voltage Measurement... 13:25:47 Voltage Offset Correction: v_off_ini = 2502.742 uV, v_off_fin = 2498.428 uV 13:25:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 21.961 uVs 13:25:51 I1X Average and RMS of Measurements VT = -33.580 +- 6.036 uVs I1X = 6.716 +- 1.207 uTm 13:25:53 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:25:58 Integrated Voltage Measurement... 13:26:07 Voltage Offset Correction: v_off_ini = 2525.250 uV, v_off_fin = 2504.126 uV 13:26:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -265.367 uVs 13:26:07 Integrated Voltage Measurement... 13:26:15 Voltage Offset Correction: v_off_ini = 2536.725 uV, v_off_fin = 2536.674 uV 13:26:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 265.268 uVs 13:26:16 Integrated Voltage Measurement... 13:26:24 Voltage Offset Correction: v_off_ini = 2492.128 uV, v_off_fin = 2496.008 uV 13:26:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -266.463 uVs 13:26:25 Integrated Voltage Measurement... 13:26:33 Voltage Offset Correction: v_off_ini = 2529.133 uV, v_off_fin = 2514.834 uV 13:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 271.186 uVs 13:26:34 Integrated Voltage Measurement... 13:26:42 Voltage Offset Correction: v_off_ini = 2517.959 uV, v_off_fin = 2496.259 uV 13:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.343 uVs 13:26:43 Integrated Voltage Measurement... 13:26:51 Voltage Offset Correction: v_off_ini = 2507.980 uV, v_off_fin = 2502.008 uV 13:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 266.410 uVs 13:26:56 I1Y Average and RMS of Measurements VT = -265.006 +- 3.252 uVs I1Y = -53.002 +- 0.651 uTm 13:26:58 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:27:01 Integrated Voltage Measurement... 13:27:10 Voltage Offset Correction: v_off_ini = 2484.314 uV, v_off_fin = 2465.726 uV 13:27:10 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 0.689 uVs 13:27:10 Integrated Voltage Measurement... 13:27:19 Voltage Offset Correction: v_off_ini = 2480.110 uV, v_off_fin = 2496.175 uV 13:27:19 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.046 uVs 13:27:19 Integrated Voltage Measurement... 13:27:28 Voltage Offset Correction: v_off_ini = 2484.977 uV, v_off_fin = 2486.426 uV 13:27:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.897 uVs 13:27:28 Integrated Voltage Measurement... 13:27:37 Voltage Offset Correction: v_off_ini = 2496.878 uV, v_off_fin = 2502.064 uV 13:27:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.324 uVs 13:27:37 Integrated Voltage Measurement... 13:27:46 Voltage Offset Correction: v_off_ini = 2471.126 uV, v_off_fin = 2465.325 uV 13:27:46 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -38.705 uVs 13:27:46 Integrated Voltage Measurement... 13:27:55 Voltage Offset Correction: v_off_ini = 2499.217 uV, v_off_fin = 2500.135 uV 13:27:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 12.311 uVs 13:27:57 I2X Average and RMS of Measurements VT = -16.599 +- 6.631 uVs I2X = 1.527 +- 0.610 uTm^2 13:28:00 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 13:28:02 Integrated Voltage Measurement... 13:28:11 Voltage Offset Correction: v_off_ini = 2491.432 uV, v_off_fin = 2488.918 uV 13:28:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -288.740 uVs 13:28:11 Integrated Voltage Measurement... 13:28:20 Voltage Offset Correction: v_off_ini = 2471.384 uV, v_off_fin = 2465.288 uV 13:28:20 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 281.867 uVs 13:28:21 Integrated Voltage Measurement... 13:28:29 Voltage Offset Correction: v_off_ini = 2459.764 uV, v_off_fin = 2472.918 uV 13:28:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -267.157 uVs 13:28:30 Integrated Voltage Measurement... 13:28:39 Voltage Offset Correction: v_off_ini = 2492.113 uV, v_off_fin = 2483.210 uV 13:28:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.294 uVs 13:28:39 Integrated Voltage Measurement... 13:28:48 Voltage Offset Correction: v_off_ini = 2472.537 uV, v_off_fin = 2487.327 uV 13:28:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -303.360 uVs 13:28:48 Integrated Voltage Measurement... 13:28:57 Voltage Offset Correction: v_off_ini = 2498.166 uV, v_off_fin = 2497.708 uV 13:28:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 296.540 uVs 13:28:59 I2Y Average and RMS of Measurements VT = -284.326 +- 13.174 uVs I2Y = -26.158 +- 1.212 uTm^2 13:29:03 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:29:07 Integrated Voltage Measurement... 13:29:16 Voltage Offset Correction: v_off_ini = 2486.740 uV, v_off_fin = 2489.048 uV 13:29:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.342 uVs 13:29:16 Integrated Voltage Measurement... 13:29:25 Voltage Offset Correction: v_off_ini = 2455.364 uV, v_off_fin = 2470.071 uV 13:29:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.098 uVs 13:29:25 Integrated Voltage Measurement... 13:29:34 Voltage Offset Correction: v_off_ini = 2454.859 uV, v_off_fin = 2445.353 uV 13:29:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -18.755 uVs 13:29:34 Integrated Voltage Measurement... 13:29:43 Voltage Offset Correction: v_off_ini = 2445.188 uV, v_off_fin = 2448.947 uV 13:29:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 34.046 uVs 13:29:43 Integrated Voltage Measurement... 13:29:52 Voltage Offset Correction: v_off_ini = 2462.507 uV, v_off_fin = 2476.682 uV 13:29:52 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -19.110 uVs 13:29:52 Integrated Voltage Measurement... 13:30:01 Voltage Offset Correction: v_off_ini = 2474.907 uV, v_off_fin = 2457.859 uV 13:30:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 16.133 uVs 13:30:06 I1X Average and RMS of Measurements VT = -25.081 +- 5.629 uVs I1X = 5.016 +- 1.126 uTm 13:30:08 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:30:12 Integrated Voltage Measurement... 13:30:21 Voltage Offset Correction: v_off_ini = 2484.369 uV, v_off_fin = 2482.756 uV 13:30:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -261.155 uVs 13:30:21 Integrated Voltage Measurement... 13:30:30 Voltage Offset Correction: v_off_ini = 2494.464 uV, v_off_fin = 2506.404 uV 13:30:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 259.371 uVs 13:30:30 Integrated Voltage Measurement... 13:30:39 Voltage Offset Correction: v_off_ini = 2504.104 uV, v_off_fin = 2485.977 uV 13:30:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.492 uVs 13:30:39 Integrated Voltage Measurement... 13:30:48 Voltage Offset Correction: v_off_ini = 2483.697 uV, v_off_fin = 2504.186 uV 13:30:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 263.893 uVs 13:30:48 Integrated Voltage Measurement... 13:30:57 Voltage Offset Correction: v_off_ini = 2490.443 uV, v_off_fin = 2488.271 uV 13:30:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.713 uVs 13:30:57 Integrated Voltage Measurement... 13:31:06 Voltage Offset Correction: v_off_ini = 2504.758 uV, v_off_fin = 2490.028 uV 13:31:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.940 uVs 13:31:10 I1Y Average and RMS of Measurements VT = -253.594 +- 6.202 uVs I1Y = -50.719 +- 1.240 uTm 13:31:13 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:31:16 Integrated Voltage Measurement... 13:31:25 Voltage Offset Correction: v_off_ini = 2467.541 uV, v_off_fin = 2463.547 uV 13:31:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -0.509 uVs 13:31:25 Integrated Voltage Measurement... 13:31:34 Voltage Offset Correction: v_off_ini = 2455.641 uV, v_off_fin = 2492.502 uV 13:31:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.433 uVs 13:31:34 Integrated Voltage Measurement... 13:31:43 Voltage Offset Correction: v_off_ini = 2475.283 uV, v_off_fin = 2479.673 uV 13:31:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 9.355 uVs 13:31:43 Integrated Voltage Measurement... 13:31:52 Voltage Offset Correction: v_off_ini = 2475.582 uV, v_off_fin = 2489.230 uV 13:31:52 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -25.368 uVs 13:31:52 Integrated Voltage Measurement... 13:32:01 Voltage Offset Correction: v_off_ini = 2486.956 uV, v_off_fin = 2479.037 uV 13:32:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.558 uVs 13:32:01 Integrated Voltage Measurement... 13:32:10 Voltage Offset Correction: v_off_ini = 2482.958 uV, v_off_fin = 2463.724 uV 13:32:10 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -21.663 uVs 13:32:12 I2X Average and RMS of Measurements VT = 3.981 +- 12.371 uVs I2X = -0.366 +- 1.138 uTm^2 13:32:15 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 13:32:17 Integrated Voltage Measurement... 13:32:26 Voltage Offset Correction: v_off_ini = 2459.266 uV, v_off_fin = 2472.780 uV 13:32:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -249.984 uVs 13:32:26 Integrated Voltage Measurement... 13:32:35 Voltage Offset Correction: v_off_ini = 2473.485 uV, v_off_fin = 2464.811 uV 13:32:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 264.895 uVs 13:32:35 Integrated Voltage Measurement... 13:32:44 Voltage Offset Correction: v_off_ini = 2462.942 uV, v_off_fin = 2480.937 uV 13:32:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.073 uVs 13:32:44 Integrated Voltage Measurement... 13:32:53 Voltage Offset Correction: v_off_ini = 2484.911 uV, v_off_fin = 2476.378 uV 13:32:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.386 uVs 13:32:53 Integrated Voltage Measurement... 13:33:02 Voltage Offset Correction: v_off_ini = 2478.102 uV, v_off_fin = 2494.964 uV 13:33:02 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -268.836 uVs 13:33:02 Integrated Voltage Measurement... 13:33:11 Voltage Offset Correction: v_off_ini = 2488.869 uV, v_off_fin = 2482.580 uV 13:33:11 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.403 uVs 13:33:14 I2Y Average and RMS of Measurements VT = -260.930 +- 4.732 uVs I2Y = -24.006 +- 0.435 uTm^2 13:33:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:33:22 Integrated Voltage Measurement... 13:33:31 Voltage Offset Correction: v_off_ini = 2454.682 uV, v_off_fin = 2457.278 uV 13:33:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -4.971 uVs 13:33:31 Integrated Voltage Measurement... 13:33:40 Voltage Offset Correction: v_off_ini = 2469.946 uV, v_off_fin = 2475.880 uV 13:33:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.445 uVs 13:33:40 Integrated Voltage Measurement... 13:33:49 Voltage Offset Correction: v_off_ini = 2459.484 uV, v_off_fin = 2442.290 uV 13:33:49 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.542 uVs 13:33:49 Integrated Voltage Measurement... 13:33:58 Voltage Offset Correction: v_off_ini = 2453.088 uV, v_off_fin = 2462.291 uV 13:33:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.678 uVs 13:33:58 Integrated Voltage Measurement... 13:34:07 Voltage Offset Correction: v_off_ini = 2467.896 uV, v_off_fin = 2463.841 uV 13:34:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.759 uVs 13:34:07 Integrated Voltage Measurement... 13:34:16 Voltage Offset Correction: v_off_ini = 2467.312 uV, v_off_fin = 2457.865 uV 13:34:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.802 uVs 13:34:20 I1X Average and RMS of Measurements VT = -21.699 +- 5.363 uVs I1X = 4.340 +- 1.073 uTm 13:34:23 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:34:27 Integrated Voltage Measurement... 13:34:36 Voltage Offset Correction: v_off_ini = 2473.165 uV, v_off_fin = 2466.432 uV 13:34:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.498 uVs 13:34:36 Integrated Voltage Measurement... 13:34:45 Voltage Offset Correction: v_off_ini = 2461.742 uV, v_off_fin = 2481.875 uV 13:34:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 237.420 uVs 13:34:45 Integrated Voltage Measurement... 13:34:54 Voltage Offset Correction: v_off_ini = 2471.290 uV, v_off_fin = 2464.685 uV 13:34:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -216.064 uVs 13:34:54 Integrated Voltage Measurement... 13:35:03 Voltage Offset Correction: v_off_ini = 2476.767 uV, v_off_fin = 2469.971 uV 13:35:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 253.601 uVs 13:35:03 Integrated Voltage Measurement... 13:35:12 Voltage Offset Correction: v_off_ini = 2469.097 uV, v_off_fin = 2459.395 uV 13:35:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -227.295 uVs 13:35:12 Integrated Voltage Measurement... 13:35:21 Voltage Offset Correction: v_off_ini = 2461.927 uV, v_off_fin = 2484.156 uV 13:35:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 261.145 uVs 13:35:25 I1Y Average and RMS of Measurements VT = -240.837 +- 4.257 uVs I1Y = -48.167 +- 0.851 uTm 13:35:28 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:35:30 Integrated Voltage Measurement... 13:35:39 Voltage Offset Correction: v_off_ini = 2455.369 uV, v_off_fin = 2450.373 uV 13:35:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.681 uVs 13:35:39 Integrated Voltage Measurement... 13:35:48 Voltage Offset Correction: v_off_ini = 2468.118 uV, v_off_fin = 2477.218 uV 13:35:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.956 uVs 13:35:48 Integrated Voltage Measurement... 13:35:57 Voltage Offset Correction: v_off_ini = 2455.618 uV, v_off_fin = 2439.393 uV 13:35:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -2.255 uVs 13:35:57 Integrated Voltage Measurement... 13:36:06 Voltage Offset Correction: v_off_ini = 2451.199 uV, v_off_fin = 2470.110 uV 13:36:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.343 uVs 13:36:06 Integrated Voltage Measurement... 13:36:15 Voltage Offset Correction: v_off_ini = 2455.636 uV, v_off_fin = 2440.790 uV 13:36:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -35.646 uVs 13:36:15 Integrated Voltage Measurement... 13:36:24 Voltage Offset Correction: v_off_ini = 2477.918 uV, v_off_fin = 2467.831 uV 13:36:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.666 uVs 13:36:27 I2X Average and RMS of Measurements VT = -12.698 +- 9.938 uVs I2X = 1.168 +- 0.914 uTm^2 13:36:29 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:36:32 Integrated Voltage Measurement... 13:36:41 Voltage Offset Correction: v_off_ini = 2464.126 uV, v_off_fin = 2462.107 uV 13:36:41 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -266.821 uVs 13:36:41 Integrated Voltage Measurement... 13:36:50 Voltage Offset Correction: v_off_ini = 2471.757 uV, v_off_fin = 2464.265 uV 13:36:50 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 279.985 uVs 13:36:50 Integrated Voltage Measurement... 13:36:59 Voltage Offset Correction: v_off_ini = 2422.905 uV, v_off_fin = 2461.152 uV 13:36:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -264.676 uVs 13:36:59 Integrated Voltage Measurement... 13:37:08 Voltage Offset Correction: v_off_ini = 2444.451 uV, v_off_fin = 2434.861 uV 13:37:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 268.863 uVs 13:37:08 Integrated Voltage Measurement... 13:37:17 Voltage Offset Correction: v_off_ini = 2435.632 uV, v_off_fin = 2441.908 uV 13:37:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.776 uVs 13:37:17 Integrated Voltage Measurement... 13:37:26 Voltage Offset Correction: v_off_ini = 2453.297 uV, v_off_fin = 2445.069 uV 13:37:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 248.876 uVs 13:37:29 I2Y Average and RMS of Measurements VT = -262.666 +- 10.838 uVs I2Y = -24.165 +- 0.997 uTm^2 13:37:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:37:37 Integrated Voltage Measurement... 13:37:46 Voltage Offset Correction: v_off_ini = 2462.941 uV, v_off_fin = 2446.673 uV 13:37:46 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -41.000 uVs 13:37:46 Integrated Voltage Measurement... 13:37:55 Voltage Offset Correction: v_off_ini = 2471.822 uV, v_off_fin = 2463.715 uV 13:37:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.856 uVs 13:37:55 Integrated Voltage Measurement... 13:38:04 Voltage Offset Correction: v_off_ini = 2455.699 uV, v_off_fin = 2426.908 uV 13:38:04 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.963 uVs 13:38:04 Integrated Voltage Measurement... 13:38:13 Voltage Offset Correction: v_off_ini = 2416.213 uV, v_off_fin = 2439.123 uV 13:38:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 4.081 uVs 13:38:13 Integrated Voltage Measurement... 13:38:22 Voltage Offset Correction: v_off_ini = 2434.494 uV, v_off_fin = 2438.380 uV 13:38:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.402 uVs 13:38:22 Integrated Voltage Measurement... 13:38:31 Voltage Offset Correction: v_off_ini = 2437.256 uV, v_off_fin = 2441.211 uV 13:38:31 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 27.229 uVs 13:38:35 I1X Average and RMS of Measurements VT = -26.922 +- 4.676 uVs I1X = 5.385 +- 0.935 uTm 13:38:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:38:42 Integrated Voltage Measurement... 13:38:51 Voltage Offset Correction: v_off_ini = 2439.320 uV, v_off_fin = 2425.932 uV 13:38:51 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -221.174 uVs 13:38:51 Integrated Voltage Measurement... 13:39:00 Voltage Offset Correction: v_off_ini = 2427.129 uV, v_off_fin = 2431.481 uV 13:39:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 220.150 uVs 13:39:00 Integrated Voltage Measurement... 13:39:09 Voltage Offset Correction: v_off_ini = 2426.283 uV, v_off_fin = 2411.135 uV 13:39:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.513 uVs 13:39:09 Integrated Voltage Measurement... 13:39:18 Voltage Offset Correction: v_off_ini = 2429.005 uV, v_off_fin = 2440.784 uV 13:39:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.441 uVs 13:39:18 Integrated Voltage Measurement... 13:39:27 Voltage Offset Correction: v_off_ini = 2441.024 uV, v_off_fin = 2437.737 uV 13:39:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -212.607 uVs 13:39:27 Integrated Voltage Measurement... 13:39:36 Voltage Offset Correction: v_off_ini = 2440.646 uV, v_off_fin = 2461.052 uV 13:39:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 228.085 uVs 13:39:40 I1Y Average and RMS of Measurements VT = -222.662 +- 3.054 uVs I1Y = -44.533 +- 0.610 uTm 13:39:42 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:39:45 Integrated Voltage Measurement... 13:39:54 Voltage Offset Correction: v_off_ini = 2457.125 uV, v_off_fin = 2443.529 uV 13:39:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -3.067 uVs 13:39:54 Integrated Voltage Measurement... 13:40:03 Voltage Offset Correction: v_off_ini = 2449.424 uV, v_off_fin = 2447.574 uV 13:40:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 11.888 uVs 13:40:03 Integrated Voltage Measurement... 13:40:12 Voltage Offset Correction: v_off_ini = 2444.864 uV, v_off_fin = 2434.135 uV 13:40:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 5.344 uVs 13:40:12 Integrated Voltage Measurement... 13:40:21 Voltage Offset Correction: v_off_ini = 2446.057 uV, v_off_fin = 2452.589 uV 13:40:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.858 uVs 13:40:21 Integrated Voltage Measurement... 13:40:30 Voltage Offset Correction: v_off_ini = 2439.351 uV, v_off_fin = 2431.807 uV 13:40:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 14.298 uVs 13:40:30 Integrated Voltage Measurement... 13:40:39 Voltage Offset Correction: v_off_ini = 2437.408 uV, v_off_fin = 2450.825 uV 13:40:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 4.686 uVs 13:40:42 I2X Average and RMS of Measurements VT = 0.310 +- 5.528 uVs I2X = -0.028 +- 0.509 uTm^2 13:40:44 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 13:40:47 Integrated Voltage Measurement... 13:40:56 Voltage Offset Correction: v_off_ini = 2414.118 uV, v_off_fin = 2418.078 uV 13:40:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -250.295 uVs 13:40:56 Integrated Voltage Measurement... 13:41:05 Voltage Offset Correction: v_off_ini = 2417.743 uV, v_off_fin = 2427.662 uV 13:41:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.046 uVs 13:41:05 Integrated Voltage Measurement... 13:41:14 Voltage Offset Correction: v_off_ini = 2429.447 uV, v_off_fin = 2438.168 uV 13:41:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -269.873 uVs 13:41:14 Integrated Voltage Measurement... 13:41:23 Voltage Offset Correction: v_off_ini = 2416.289 uV, v_off_fin = 2431.838 uV 13:41:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 244.247 uVs 13:41:23 Integrated Voltage Measurement... 13:41:32 Voltage Offset Correction: v_off_ini = 2431.199 uV, v_off_fin = 2419.593 uV 13:41:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.570 uVs 13:41:32 Integrated Voltage Measurement... 13:41:41 Voltage Offset Correction: v_off_ini = 2407.639 uV, v_off_fin = 2428.285 uV 13:41:41 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 245.897 uVs 13:41:43 I2Y Average and RMS of Measurements VT = -250.155 +- 4.883 uVs I2Y = -23.015 +- 0.449 uTm^2 13:41:47 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:41:51 Integrated Voltage Measurement... 13:42:00 Voltage Offset Correction: v_off_ini = 2457.419 uV, v_off_fin = 2441.312 uV 13:42:00 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -15.894 uVs 13:42:00 Integrated Voltage Measurement... 13:42:09 Voltage Offset Correction: v_off_ini = 2428.678 uV, v_off_fin = 2421.964 uV 13:42:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -0.947 uVs 13:42:09 Integrated Voltage Measurement... 13:42:18 Voltage Offset Correction: v_off_ini = 2411.821 uV, v_off_fin = 2421.016 uV 13:42:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -17.962 uVs 13:42:18 Integrated Voltage Measurement... 13:42:27 Voltage Offset Correction: v_off_ini = 2406.777 uV, v_off_fin = 2411.593 uV 13:42:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 8.267 uVs 13:42:27 Integrated Voltage Measurement... 13:42:36 Voltage Offset Correction: v_off_ini = 2435.273 uV, v_off_fin = 2430.948 uV 13:42:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -2.354 uVs 13:42:37 Integrated Voltage Measurement... 13:42:45 Voltage Offset Correction: v_off_ini = 2422.623 uV, v_off_fin = 2428.782 uV 13:42:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.959 uVs 13:42:50 I1X Average and RMS of Measurements VT = -13.248 +- 4.770 uVs I1X = 2.650 +- 0.954 uTm 13:42:52 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:42:56 Integrated Voltage Measurement... 13:43:05 Voltage Offset Correction: v_off_ini = 2419.552 uV, v_off_fin = 2402.483 uV 13:43:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.113 uVs 13:43:05 Integrated Voltage Measurement... 13:43:14 Voltage Offset Correction: v_off_ini = 2433.359 uV, v_off_fin = 2436.069 uV 13:43:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.683 uVs 13:43:14 Integrated Voltage Measurement... 13:43:23 Voltage Offset Correction: v_off_ini = 2412.031 uV, v_off_fin = 2417.482 uV 13:43:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.778 uVs 13:43:23 Integrated Voltage Measurement... 13:43:32 Voltage Offset Correction: v_off_ini = 2416.752 uV, v_off_fin = 2432.424 uV 13:43:32 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 225.073 uVs 13:43:32 Integrated Voltage Measurement... 13:43:41 Voltage Offset Correction: v_off_ini = 2421.406 uV, v_off_fin = 2407.009 uV 13:43:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -207.999 uVs 13:43:41 Integrated Voltage Measurement... 13:43:50 Voltage Offset Correction: v_off_ini = 2429.417 uV, v_off_fin = 2437.165 uV 13:43:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.263 uVs 13:43:55 I1Y Average and RMS of Measurements VT = -220.652 +- 5.143 uVs I1Y = -44.129 +- 1.029 uTm 13:43:57 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:44:00 Integrated Voltage Measurement... 13:44:09 Voltage Offset Correction: v_off_ini = 2400.530 uV, v_off_fin = 2385.013 uV 13:44:09 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.463 uVs 13:44:09 Integrated Voltage Measurement... 13:44:18 Voltage Offset Correction: v_off_ini = 2423.646 uV, v_off_fin = 2422.301 uV 13:44:18 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.348 uVs 13:44:18 Integrated Voltage Measurement... 13:44:27 Voltage Offset Correction: v_off_ini = 2425.985 uV, v_off_fin = 2434.024 uV 13:44:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -6.658 uVs 13:44:27 Integrated Voltage Measurement... 13:44:36 Voltage Offset Correction: v_off_ini = 2432.448 uV, v_off_fin = 2447.871 uV 13:44:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -1.698 uVs 13:44:36 Integrated Voltage Measurement... 13:44:45 Voltage Offset Correction: v_off_ini = 2420.931 uV, v_off_fin = 2425.081 uV 13:44:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 17.727 uVs 13:44:45 Integrated Voltage Measurement... 13:44:54 Voltage Offset Correction: v_off_ini = 2430.982 uV, v_off_fin = 2431.918 uV 13:44:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 0.545 uVs 13:44:56 I2X Average and RMS of Measurements VT = 3.506 +- 4.564 uVs I2X = -0.323 +- 0.420 uTm^2 13:44:59 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 13:45:01 Integrated Voltage Measurement... 13:45:10 Voltage Offset Correction: v_off_ini = 2429.581 uV, v_off_fin = 2422.333 uV 13:45:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -232.750 uVs 13:45:10 Integrated Voltage Measurement... 13:45:19 Voltage Offset Correction: v_off_ini = 2438.796 uV, v_off_fin = 2453.899 uV 13:45:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.795 uVs 13:45:19 Integrated Voltage Measurement... 13:45:28 Voltage Offset Correction: v_off_ini = 2446.987 uV, v_off_fin = 2438.298 uV 13:45:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.051 uVs 13:45:28 Integrated Voltage Measurement... 13:45:37 Voltage Offset Correction: v_off_ini = 2432.823 uV, v_off_fin = 2428.423 uV 13:45:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 232.248 uVs 13:45:37 Integrated Voltage Measurement... 13:45:46 Voltage Offset Correction: v_off_ini = 2427.955 uV, v_off_fin = 2398.872 uV 13:45:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -242.764 uVs 13:45:46 Integrated Voltage Measurement... 13:45:55 Voltage Offset Correction: v_off_ini = 2449.379 uV, v_off_fin = 2417.386 uV 13:45:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 235.120 uVs 13:45:58 I2Y Average and RMS of Measurements VT = -239.955 +- 1.643 uVs I2Y = -22.076 +- 0.151 uTm^2 13:46:22 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:46:26 Integrated Voltage Measurement... 13:46:35 Voltage Offset Correction: v_off_ini = 2429.160 uV, v_off_fin = 2431.264 uV 13:46:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.840 uVs 13:46:35 Integrated Voltage Measurement... 13:46:44 Voltage Offset Correction: v_off_ini = 2416.751 uV, v_off_fin = 2423.088 uV 13:46:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 94.525 uVs 13:46:44 Integrated Voltage Measurement... 13:46:53 Voltage Offset Correction: v_off_ini = 2413.017 uV, v_off_fin = 2420.260 uV 13:46:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -59.510 uVs 13:46:53 Integrated Voltage Measurement... 13:47:02 Voltage Offset Correction: v_off_ini = 2430.420 uV, v_off_fin = 2428.812 uV 13:47:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 81.150 uVs 13:47:02 Integrated Voltage Measurement... 13:47:11 Voltage Offset Correction: v_off_ini = 2397.853 uV, v_off_fin = 2412.823 uV 13:47:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -93.479 uVs 13:47:11 Integrated Voltage Measurement... 13:47:20 Voltage Offset Correction: v_off_ini = 2415.126 uV, v_off_fin = 2407.781 uV 13:47:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.740 uVs 13:47:24 I1X Average and RMS of Measurements VT = -78.374 +- 5.774 uVs I1X = 15.676 +- 1.155 uTm 13:47:27 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:47:31 Integrated Voltage Measurement... 13:47:40 Voltage Offset Correction: v_off_ini = 2396.302 uV, v_off_fin = 2400.380 uV 13:47:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -231.284 uVs 13:47:40 Integrated Voltage Measurement... 13:47:49 Voltage Offset Correction: v_off_ini = 2394.365 uV, v_off_fin = 2428.329 uV 13:47:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 210.406 uVs 13:47:49 Integrated Voltage Measurement... 13:47:58 Voltage Offset Correction: v_off_ini = 2417.908 uV, v_off_fin = 2408.136 uV 13:47:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.134 uVs 13:47:58 Integrated Voltage Measurement... 13:48:07 Voltage Offset Correction: v_off_ini = 2405.432 uV, v_off_fin = 2432.032 uV 13:48:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 215.216 uVs 13:48:07 Integrated Voltage Measurement... 13:48:16 Voltage Offset Correction: v_off_ini = 2415.008 uV, v_off_fin = 2396.830 uV 13:48:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.578 uVs 13:48:16 Integrated Voltage Measurement... 13:48:25 Voltage Offset Correction: v_off_ini = 2410.944 uV, v_off_fin = 2414.382 uV 13:48:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.572 uVs 13:48:29 I1Y Average and RMS of Measurements VT = -217.365 +- 2.976 uVs I1Y = -43.474 +- 0.596 uTm 13:48:34 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:48:37 Integrated Voltage Measurement... 13:48:46 Voltage Offset Correction: v_off_ini = 2389.435 uV, v_off_fin = 2384.555 uV 13:48:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -44.822 uVs 13:48:46 Integrated Voltage Measurement... 13:48:55 Voltage Offset Correction: v_off_ini = 2395.415 uV, v_off_fin = 2408.858 uV 13:48:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 19.147 uVs 13:48:55 Integrated Voltage Measurement... 13:49:04 Voltage Offset Correction: v_off_ini = 2394.105 uV, v_off_fin = 2383.716 uV 13:49:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.729 uVs 13:49:04 Integrated Voltage Measurement... 13:49:13 Voltage Offset Correction: v_off_ini = 2383.859 uV, v_off_fin = 2389.943 uV 13:49:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 28.383 uVs 13:49:13 Integrated Voltage Measurement... 13:49:22 Voltage Offset Correction: v_off_ini = 2383.988 uV, v_off_fin = 2375.425 uV 13:49:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.622 uVs 13:49:22 Integrated Voltage Measurement... 13:49:31 Voltage Offset Correction: v_off_ini = 2369.817 uV, v_off_fin = 2387.728 uV 13:49:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.340 uVs 13:49:33 I2X Average and RMS of Measurements VT = -38.841 +- 9.295 uVs I2X = 3.573 +- 0.855 uTm^2 13:49:38 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 13:49:41 Integrated Voltage Measurement... 13:49:50 Voltage Offset Correction: v_off_ini = 2402.269 uV, v_off_fin = 2387.047 uV 13:49:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.412 uVs 13:49:50 Integrated Voltage Measurement... 13:49:59 Voltage Offset Correction: v_off_ini = 2367.408 uV, v_off_fin = 2367.409 uV 13:49:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.085 uVs 13:49:59 Integrated Voltage Measurement... 13:50:08 Voltage Offset Correction: v_off_ini = 2392.222 uV, v_off_fin = 2387.707 uV 13:50:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.902 uVs 13:50:08 Integrated Voltage Measurement... 13:50:17 Voltage Offset Correction: v_off_ini = 2382.991 uV, v_off_fin = 2394.237 uV 13:50:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 234.933 uVs 13:50:17 Integrated Voltage Measurement... 13:50:26 Voltage Offset Correction: v_off_ini = 2382.274 uV, v_off_fin = 2383.064 uV 13:50:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.827 uVs 13:50:26 Integrated Voltage Measurement... 13:50:35 Voltage Offset Correction: v_off_ini = 2393.734 uV, v_off_fin = 2389.622 uV 13:50:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 221.139 uVs 13:50:38 I2Y Average and RMS of Measurements VT = -236.216 +- 5.126 uVs I2Y = -21.732 +- 0.472 uTm^2 13:50:42 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:50:46 Integrated Voltage Measurement... 13:50:55 Voltage Offset Correction: v_off_ini = 2387.120 uV, v_off_fin = 2380.804 uV 13:50:55 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -72.221 uVs 13:50:55 Integrated Voltage Measurement... 13:51:04 Voltage Offset Correction: v_off_ini = 2369.706 uV, v_off_fin = 2390.751 uV 13:51:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 24.513 uVs 13:51:04 Integrated Voltage Measurement... 13:51:13 Voltage Offset Correction: v_off_ini = 2404.767 uV, v_off_fin = 2379.458 uV 13:51:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -49.398 uVs 13:51:13 Integrated Voltage Measurement... 13:51:22 Voltage Offset Correction: v_off_ini = 2393.230 uV, v_off_fin = 2388.102 uV 13:51:22 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 91.066 uVs 13:51:22 Integrated Voltage Measurement... 13:51:31 Voltage Offset Correction: v_off_ini = 2391.563 uV, v_off_fin = 2401.713 uV 13:51:31 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4999 mm dXY = -0.4999 mm VT = -79.498 uVs 13:51:31 Integrated Voltage Measurement... 13:51:40 Voltage Offset Correction: v_off_ini = 2396.895 uV, v_off_fin = 2390.910 uV 13:51:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 54.927 uVs 13:51:45 I1X Average and RMS of Measurements VT = -61.937 +- 9.674 uVs I1X = 12.390 +- 1.935 uTm 13:51:47 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:51:51 Integrated Voltage Measurement... 13:52:00 Voltage Offset Correction: v_off_ini = 2383.754 uV, v_off_fin = 2384.808 uV 13:52:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -209.469 uVs 13:52:00 Integrated Voltage Measurement... 13:52:09 Voltage Offset Correction: v_off_ini = 2385.022 uV, v_off_fin = 2388.180 uV 13:52:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 233.655 uVs 13:52:09 Integrated Voltage Measurement... 13:52:18 Voltage Offset Correction: v_off_ini = 2345.782 uV, v_off_fin = 2354.118 uV 13:52:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.194 uVs 13:52:18 Integrated Voltage Measurement... 13:52:27 Voltage Offset Correction: v_off_ini = 2357.591 uV, v_off_fin = 2368.088 uV 13:52:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 218.539 uVs 13:52:27 Integrated Voltage Measurement... 13:52:36 Voltage Offset Correction: v_off_ini = 2362.654 uV, v_off_fin = 2366.080 uV 13:52:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -219.984 uVs 13:52:36 Integrated Voltage Measurement... 13:52:45 Voltage Offset Correction: v_off_ini = 2363.419 uV, v_off_fin = 2391.471 uV 13:52:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.352 uVs 13:52:49 I1Y Average and RMS of Measurements VT = -221.199 +- 0.590 uVs I1Y = -44.240 +- 0.118 uTm 13:52:55 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:52:57 Integrated Voltage Measurement... 13:53:06 Voltage Offset Correction: v_off_ini = 2366.384 uV, v_off_fin = 2359.337 uV 13:53:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -50.763 uVs 13:53:06 Integrated Voltage Measurement... 13:53:15 Voltage Offset Correction: v_off_ini = 2395.603 uV, v_off_fin = 2400.697 uV 13:53:15 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = 10.327 uVs 13:53:15 Integrated Voltage Measurement... 13:53:24 Voltage Offset Correction: v_off_ini = 2382.028 uV, v_off_fin = 2360.591 uV 13:53:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -40.894 uVs 13:53:24 Integrated Voltage Measurement... 13:53:33 Voltage Offset Correction: v_off_ini = 2388.518 uV, v_off_fin = 2393.390 uV 13:53:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.398 uVs 13:53:33 Integrated Voltage Measurement... 13:53:42 Voltage Offset Correction: v_off_ini = 2385.149 uV, v_off_fin = 2368.074 uV 13:53:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -21.823 uVs 13:53:42 Integrated Voltage Measurement... 13:53:51 Voltage Offset Correction: v_off_ini = 2378.045 uV, v_off_fin = 2393.374 uV 13:53:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 37.855 uVs 13:53:54 I2X Average and RMS of Measurements VT = -32.510 +- 3.291 uVs I2X = 2.991 +- 0.303 uTm^2 13:53:59 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 13:54:01 Integrated Voltage Measurement... 13:54:10 Voltage Offset Correction: v_off_ini = 2370.044 uV, v_off_fin = 2380.107 uV 13:54:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.957 uVs 13:54:10 Integrated Voltage Measurement... 13:54:19 Voltage Offset Correction: v_off_ini = 2373.062 uV, v_off_fin = 2368.456 uV 13:54:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 211.689 uVs 13:54:19 Integrated Voltage Measurement... 13:54:28 Voltage Offset Correction: v_off_ini = 2360.427 uV, v_off_fin = 2373.514 uV 13:54:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -258.610 uVs 13:54:29 Integrated Voltage Measurement... 13:54:38 Voltage Offset Correction: v_off_ini = 2400.086 uV, v_off_fin = 2366.856 uV 13:54:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 239.636 uVs 13:54:38 Integrated Voltage Measurement... 13:54:47 Voltage Offset Correction: v_off_ini = 2361.224 uV, v_off_fin = 2360.923 uV 13:54:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.874 uVs 13:54:47 Integrated Voltage Measurement... 13:54:56 Voltage Offset Correction: v_off_ini = 2353.488 uV, v_off_fin = 2357.246 uV 13:54:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 222.605 uVs 13:54:58 I2Y Average and RMS of Measurements VT = -235.395 +- 9.725 uVs I2Y = -21.656 +- 0.895 uTm^2 13:55:03 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:55:07 Integrated Voltage Measurement... 13:55:16 Voltage Offset Correction: v_off_ini = 2348.533 uV, v_off_fin = 2338.608 uV 13:55:16 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -10.838 uVs 13:55:16 Integrated Voltage Measurement... 13:55:25 Voltage Offset Correction: v_off_ini = 2356.411 uV, v_off_fin = 2361.555 uV 13:55:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.744 uVs 13:55:25 Integrated Voltage Measurement... 13:55:34 Voltage Offset Correction: v_off_ini = 2335.587 uV, v_off_fin = 2333.968 uV 13:55:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -25.957 uVs 13:55:34 Integrated Voltage Measurement... 13:55:43 Voltage Offset Correction: v_off_ini = 2319.828 uV, v_off_fin = 2328.344 uV 13:55:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 30.664 uVs 13:55:43 Integrated Voltage Measurement... 13:55:52 Voltage Offset Correction: v_off_ini = 2329.605 uV, v_off_fin = 2313.269 uV 13:55:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -67.717 uVs 13:55:52 Integrated Voltage Measurement... 13:56:01 Voltage Offset Correction: v_off_ini = 2344.634 uV, v_off_fin = 2355.390 uV 13:56:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 41.170 uVs 13:56:05 I1X Average and RMS of Measurements VT = -38.515 +- 11.411 uVs I1X = 7.703 +- 2.282 uTm 13:56:08 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:56:12 Integrated Voltage Measurement... 13:56:21 Voltage Offset Correction: v_off_ini = 2353.133 uV, v_off_fin = 2357.471 uV 13:56:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -222.134 uVs 13:56:21 Integrated Voltage Measurement... 13:56:30 Voltage Offset Correction: v_off_ini = 2357.086 uV, v_off_fin = 2349.743 uV 13:56:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 235.654 uVs 13:56:30 Integrated Voltage Measurement... 13:56:39 Voltage Offset Correction: v_off_ini = 2347.189 uV, v_off_fin = 2349.056 uV 13:56:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -252.228 uVs 13:56:39 Integrated Voltage Measurement... 13:56:48 Voltage Offset Correction: v_off_ini = 2345.700 uV, v_off_fin = 2357.782 uV 13:56:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 226.733 uVs 13:56:48 Integrated Voltage Measurement... 13:56:57 Voltage Offset Correction: v_off_ini = 2352.398 uV, v_off_fin = 2350.711 uV 13:56:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -236.866 uVs 13:56:57 Integrated Voltage Measurement... 13:57:06 Voltage Offset Correction: v_off_ini = 2359.643 uV, v_off_fin = 2354.958 uV 13:57:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.462 uVs 13:57:10 I1Y Average and RMS of Measurements VT = -235.846 +- 4.917 uVs I1Y = -47.169 +- 0.983 uTm 13:57:15 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:57:18 Integrated Voltage Measurement... 13:57:27 Voltage Offset Correction: v_off_ini = 2340.614 uV, v_off_fin = 2332.525 uV 13:57:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 12.838 uVs 13:57:27 Integrated Voltage Measurement... 13:57:36 Voltage Offset Correction: v_off_ini = 2327.551 uV, v_off_fin = 2349.683 uV 13:57:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -17.819 uVs 13:57:36 Integrated Voltage Measurement... 13:57:45 Voltage Offset Correction: v_off_ini = 2345.081 uV, v_off_fin = 2326.391 uV 13:57:45 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 0.987 uVs 13:57:45 Integrated Voltage Measurement... 13:57:54 Voltage Offset Correction: v_off_ini = 2336.135 uV, v_off_fin = 2344.892 uV 13:57:54 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -13.203 uVs 13:57:54 Integrated Voltage Measurement... 13:58:03 Voltage Offset Correction: v_off_ini = 2345.501 uV, v_off_fin = 2319.136 uV 13:58:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -27.117 uVs 13:58:03 Integrated Voltage Measurement... 13:58:12 Voltage Offset Correction: v_off_ini = 2322.547 uV, v_off_fin = 2337.914 uV 13:58:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 23.615 uVs 13:58:14 I2X Average and RMS of Measurements VT = -0.981 +- 17.568 uVs I2X = 0.090 +- 1.616 uTm^2 13:58:19 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 13:58:22 Integrated Voltage Measurement... 13:58:31 Voltage Offset Correction: v_off_ini = 2322.912 uV, v_off_fin = 2310.474 uV 13:58:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -246.882 uVs 13:58:31 Integrated Voltage Measurement... 13:58:40 Voltage Offset Correction: v_off_ini = 2330.430 uV, v_off_fin = 2326.328 uV 13:58:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 215.745 uVs 13:58:40 Integrated Voltage Measurement... 13:58:49 Voltage Offset Correction: v_off_ini = 2310.059 uV, v_off_fin = 2312.503 uV 13:58:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.457 uVs 13:58:49 Integrated Voltage Measurement... 13:58:58 Voltage Offset Correction: v_off_ini = 2315.880 uV, v_off_fin = 2316.101 uV 13:58:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 238.402 uVs 13:58:58 Integrated Voltage Measurement... 13:59:07 Voltage Offset Correction: v_off_ini = 2299.826 uV, v_off_fin = 2312.668 uV 13:59:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -235.936 uVs 13:59:07 Integrated Voltage Measurement... 13:59:16 Voltage Offset Correction: v_off_ini = 2325.148 uV, v_off_fin = 2328.129 uV 13:59:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 249.122 uVs 13:59:18 I2Y Average and RMS of Measurements VT = -238.924 +- 5.384 uVs I2Y = -21.981 +- 0.495 uTm^2 13:59:23 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 13:59:27 Integrated Voltage Measurement... 13:59:36 Voltage Offset Correction: v_off_ini = 2307.313 uV, v_off_fin = 2306.534 uV 13:59:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -34.577 uVs 13:59:36 Integrated Voltage Measurement... 13:59:45 Voltage Offset Correction: v_off_ini = 2324.937 uV, v_off_fin = 2326.142 uV 13:59:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -3.734 uVs 13:59:45 Integrated Voltage Measurement... 13:59:54 Voltage Offset Correction: v_off_ini = 2309.755 uV, v_off_fin = 2301.131 uV 13:59:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -5.382 uVs 13:59:54 Integrated Voltage Measurement... 14:00:03 Voltage Offset Correction: v_off_ini = 2314.616 uV, v_off_fin = 2296.896 uV 14:00:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.812 uVs 14:00:03 Integrated Voltage Measurement... 14:00:12 Voltage Offset Correction: v_off_ini = 2308.838 uV, v_off_fin = 2283.579 uV 14:00:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.470 uVs 14:00:12 Integrated Voltage Measurement... 14:00:21 Voltage Offset Correction: v_off_ini = 2295.033 uV, v_off_fin = 2280.386 uV 14:00:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 54.835 uVs 14:00:26 I1X Average and RMS of Measurements VT = -21.224 +- 8.436 uVs I1X = 4.245 +- 1.687 uTm 14:00:28 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:00:32 Integrated Voltage Measurement... 14:00:41 Voltage Offset Correction: v_off_ini = 2292.569 uV, v_off_fin = 2274.673 uV 14:00:41 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -247.625 uVs 14:00:41 Integrated Voltage Measurement... 14:00:50 Voltage Offset Correction: v_off_ini = 2273.199 uV, v_off_fin = 2292.836 uV 14:00:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.938 uVs 14:00:50 Integrated Voltage Measurement... 14:00:59 Voltage Offset Correction: v_off_ini = 2264.290 uV, v_off_fin = 2265.892 uV 14:00:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -235.019 uVs 14:00:59 Integrated Voltage Measurement... 14:01:08 Voltage Offset Correction: v_off_ini = 2278.773 uV, v_off_fin = 2283.190 uV 14:01:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.874 uVs 14:01:08 Integrated Voltage Measurement... 14:01:17 Voltage Offset Correction: v_off_ini = 2284.124 uV, v_off_fin = 2276.824 uV 14:01:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -225.002 uVs 14:01:17 Integrated Voltage Measurement... 14:01:26 Voltage Offset Correction: v_off_ini = 2251.883 uV, v_off_fin = 2268.588 uV 14:01:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.737 uVs 14:01:30 I1Y Average and RMS of Measurements VT = -241.032 +- 5.919 uVs I1Y = -48.206 +- 1.184 uTm 14:01:36 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:01:38 Integrated Voltage Measurement... 14:01:47 Voltage Offset Correction: v_off_ini = 2225.488 uV, v_off_fin = 2217.295 uV 14:01:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 11.462 uVs 14:01:47 Integrated Voltage Measurement... 14:01:56 Voltage Offset Correction: v_off_ini = 2228.726 uV, v_off_fin = 2248.546 uV 14:01:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.393 uVs 14:01:56 Integrated Voltage Measurement... 14:02:05 Voltage Offset Correction: v_off_ini = 2248.024 uV, v_off_fin = 2191.811 uV 14:02:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 14.831 uVs 14:02:05 Integrated Voltage Measurement... 14:02:14 Voltage Offset Correction: v_off_ini = 2178.204 uV, v_off_fin = 2189.828 uV 14:02:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -10.839 uVs 14:02:14 Integrated Voltage Measurement... 14:02:23 Voltage Offset Correction: v_off_ini = 2195.324 uV, v_off_fin = 2181.094 uV 14:02:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 27.071 uVs 14:02:23 Integrated Voltage Measurement... 14:02:32 Voltage Offset Correction: v_off_ini = 2186.479 uV, v_off_fin = 2178.192 uV 14:02:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -22.167 uVs 14:02:35 I2X Average and RMS of Measurements VT = 13.330 +- 9.023 uVs I2X = -1.226 +- 0.830 uTm^2 14:02:40 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:02:42 Integrated Voltage Measurement... 14:02:51 Voltage Offset Correction: v_off_ini = 2175.581 uV, v_off_fin = 2145.317 uV 14:02:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -237.299 uVs 14:02:51 Integrated Voltage Measurement... 14:03:00 Voltage Offset Correction: v_off_ini = 2128.897 uV, v_off_fin = 2125.058 uV 14:03:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 270.249 uVs 14:03:00 Integrated Voltage Measurement... 14:03:09 Voltage Offset Correction: v_off_ini = 2109.741 uV, v_off_fin = 2125.743 uV 14:03:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -254.217 uVs 14:03:09 Integrated Voltage Measurement... 14:03:18 Voltage Offset Correction: v_off_ini = 2121.863 uV, v_off_fin = 2110.009 uV 14:03:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 233.545 uVs 14:03:18 Integrated Voltage Measurement... 14:03:27 Voltage Offset Correction: v_off_ini = 2103.602 uV, v_off_fin = 2096.033 uV 14:03:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.837 uVs 14:03:27 Integrated Voltage Measurement... 14:03:36 Voltage Offset Correction: v_off_ini = 2119.225 uV, v_off_fin = 2115.947 uV 14:03:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 252.528 uVs 14:03:39 I2Y Average and RMS of Measurements VT = -248.112 +- 4.163 uVs I2Y = -22.826 +- 0.383 uTm^2 14:03:43 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:03:48 Integrated Voltage Measurement... 14:03:57 Voltage Offset Correction: v_off_ini = 2101.905 uV, v_off_fin = 2096.906 uV 14:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 21.694 uVs 14:03:57 Integrated Voltage Measurement... 14:04:06 Voltage Offset Correction: v_off_ini = 2122.161 uV, v_off_fin = 2112.467 uV 14:04:06 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -33.884 uVs 14:04:06 Integrated Voltage Measurement... 14:04:15 Voltage Offset Correction: v_off_ini = 2098.286 uV, v_off_fin = 2116.364 uV 14:04:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 5.124 uVs 14:04:15 Integrated Voltage Measurement... 14:04:24 Voltage Offset Correction: v_off_ini = 2139.673 uV, v_off_fin = 2141.847 uV 14:04:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -26.975 uVs 14:04:24 Integrated Voltage Measurement... 14:04:33 Voltage Offset Correction: v_off_ini = 2152.923 uV, v_off_fin = 2131.965 uV 14:04:33 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 17.981 uVs 14:04:33 Integrated Voltage Measurement... 14:04:42 Voltage Offset Correction: v_off_ini = 2131.207 uV, v_off_fin = 2147.360 uV 14:04:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -17.653 uVs 14:04:46 I1X Average and RMS of Measurements VT = 20.552 +- 5.168 uVs I1X = -4.110 +- 1.034 uTm 14:04:48 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:04:53 Integrated Voltage Measurement... 14:05:02 Voltage Offset Correction: v_off_ini = 2130.031 uV, v_off_fin = 2109.143 uV 14:05:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -255.898 uVs 14:05:02 Integrated Voltage Measurement... 14:05:11 Voltage Offset Correction: v_off_ini = 2125.105 uV, v_off_fin = 2141.705 uV 14:05:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 257.641 uVs 14:05:11 Integrated Voltage Measurement... 14:05:20 Voltage Offset Correction: v_off_ini = 2112.518 uV, v_off_fin = 2114.446 uV 14:05:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -228.272 uVs 14:05:20 Integrated Voltage Measurement... 14:05:29 Voltage Offset Correction: v_off_ini = 2122.931 uV, v_off_fin = 2135.112 uV 14:05:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.239 uVs 14:05:29 Integrated Voltage Measurement... 14:05:38 Voltage Offset Correction: v_off_ini = 2124.285 uV, v_off_fin = 2115.814 uV 14:05:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -246.663 uVs 14:05:38 Integrated Voltage Measurement... 14:05:47 Voltage Offset Correction: v_off_ini = 2126.910 uV, v_off_fin = 2132.293 uV 14:05:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 247.415 uVs 14:05:51 I1Y Average and RMS of Measurements VT = -247.188 +- 7.763 uVs I1Y = -49.438 +- 1.553 uTm 14:05:56 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:05:59 Integrated Voltage Measurement... 14:06:07 Voltage Offset Correction: v_off_ini = 2127.540 uV, v_off_fin = 2147.489 uV 14:06:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 32.014 uVs 14:06:08 Integrated Voltage Measurement... 14:06:17 Voltage Offset Correction: v_off_ini = 2152.587 uV, v_off_fin = 2160.469 uV 14:06:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -42.511 uVs 14:06:17 Integrated Voltage Measurement... 14:06:26 Voltage Offset Correction: v_off_ini = 2140.807 uV, v_off_fin = 2134.963 uV 14:06:26 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 68.499 uVs 14:06:26 Integrated Voltage Measurement... 14:06:35 Voltage Offset Correction: v_off_ini = 2142.628 uV, v_off_fin = 2152.832 uV 14:06:35 Integrated Voltage Measurement dXYus = 0.9999 mm, dXYds = 0.0000 mm dXY = 0.9999 mm VT = -40.662 uVs 14:06:35 Integrated Voltage Measurement... 14:06:44 Voltage Offset Correction: v_off_ini = 2125.287 uV, v_off_fin = 2100.198 uV 14:06:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 48.160 uVs 14:06:44 Integrated Voltage Measurement... 14:06:53 Voltage Offset Correction: v_off_ini = 2123.336 uV, v_off_fin = 2135.352 uV 14:06:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -45.725 uVs 14:06:55 I2X Average and RMS of Measurements VT = 46.262 +- 7.086 uVs I2X = -4.256 +- 0.652 uTm^2 14:07:00 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:07:03 Integrated Voltage Measurement... 14:07:12 Voltage Offset Correction: v_off_ini = 2123.764 uV, v_off_fin = 2126.758 uV 14:07:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -276.979 uVs 14:07:12 Integrated Voltage Measurement... 14:07:21 Voltage Offset Correction: v_off_ini = 2125.541 uV, v_off_fin = 2143.367 uV 14:07:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 242.494 uVs 14:07:21 Integrated Voltage Measurement... 14:07:30 Voltage Offset Correction: v_off_ini = 2136.185 uV, v_off_fin = 2116.628 uV 14:07:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -236.392 uVs 14:07:30 Integrated Voltage Measurement... 14:07:39 Voltage Offset Correction: v_off_ini = 2126.348 uV, v_off_fin = 2114.633 uV 14:07:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 260.150 uVs 14:07:39 Integrated Voltage Measurement... 14:07:48 Voltage Offset Correction: v_off_ini = 2121.799 uV, v_off_fin = 2125.221 uV 14:07:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -280.130 uVs 14:07:48 Integrated Voltage Measurement... 14:07:57 Voltage Offset Correction: v_off_ini = 2133.547 uV, v_off_fin = 2127.317 uV 14:07:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 243.784 uVs 14:07:59 I2Y Average and RMS of Measurements VT = -256.655 +- 5.997 uVs I2Y = -23.612 +- 0.552 uTm^2 14:08:07 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:08:11 Integrated Voltage Measurement... 14:08:20 Voltage Offset Correction: v_off_ini = 2147.094 uV, v_off_fin = 2135.246 uV 14:08:20 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -33.431 uVs 14:08:20 Integrated Voltage Measurement... 14:08:29 Voltage Offset Correction: v_off_ini = 2136.824 uV, v_off_fin = 2132.122 uV 14:08:29 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 19.645 uVs 14:08:29 Integrated Voltage Measurement... 14:08:38 Voltage Offset Correction: v_off_ini = 2147.713 uV, v_off_fin = 2130.195 uV 14:08:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -73.844 uVs 14:08:38 Integrated Voltage Measurement... 14:08:47 Voltage Offset Correction: v_off_ini = 2174.376 uV, v_off_fin = 2151.415 uV 14:08:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 11.179 uVs 14:08:47 Integrated Voltage Measurement... 14:08:56 Voltage Offset Correction: v_off_ini = 2159.758 uV, v_off_fin = 2146.877 uV 14:08:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.435 uVs 14:08:56 Integrated Voltage Measurement... 14:09:05 Voltage Offset Correction: v_off_ini = 2163.438 uV, v_off_fin = 2155.959 uV 14:09:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.768 uVs 14:09:10 I1X Average and RMS of Measurements VT = -33.217 +- 6.778 uVs I1X = 6.644 +- 1.356 uTm 14:09:12 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:09:16 Integrated Voltage Measurement... 14:09:25 Voltage Offset Correction: v_off_ini = 2144.083 uV, v_off_fin = 2139.594 uV 14:09:25 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -262.650 uVs 14:09:25 Integrated Voltage Measurement... 14:09:34 Voltage Offset Correction: v_off_ini = 2136.175 uV, v_off_fin = 2161.397 uV 14:09:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.110 uVs 14:09:34 Integrated Voltage Measurement... 14:09:43 Voltage Offset Correction: v_off_ini = 2165.217 uV, v_off_fin = 2146.895 uV 14:09:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -226.116 uVs 14:09:43 Integrated Voltage Measurement... 14:09:52 Voltage Offset Correction: v_off_ini = 2149.282 uV, v_off_fin = 2163.116 uV 14:09:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 243.976 uVs 14:09:52 Integrated Voltage Measurement... 14:10:01 Voltage Offset Correction: v_off_ini = 2164.343 uV, v_off_fin = 2156.320 uV 14:10:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -259.213 uVs 14:10:01 Integrated Voltage Measurement... 14:10:10 Voltage Offset Correction: v_off_ini = 2174.818 uV, v_off_fin = 2192.042 uV 14:10:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 251.513 uVs 14:10:14 I1Y Average and RMS of Measurements VT = -249.096 +- 9.954 uVs I1Y = -49.819 +- 1.991 uTm 14:10:17 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:10:19 Integrated Voltage Measurement... 14:10:28 Voltage Offset Correction: v_off_ini = 2175.257 uV, v_off_fin = 2181.198 uV 14:10:28 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -14.337 uVs 14:10:29 Integrated Voltage Measurement... 14:10:37 Voltage Offset Correction: v_off_ini = 2199.510 uV, v_off_fin = 2198.082 uV 14:10:37 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 6.156 uVs 14:10:38 Integrated Voltage Measurement... 14:10:47 Voltage Offset Correction: v_off_ini = 2202.151 uV, v_off_fin = 2189.792 uV 14:10:47 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 1.624 uVs 14:10:47 Integrated Voltage Measurement... 14:10:56 Voltage Offset Correction: v_off_ini = 2192.118 uV, v_off_fin = 2212.718 uV 14:10:56 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -10.759 uVs 14:10:56 Integrated Voltage Measurement... 14:11:05 Voltage Offset Correction: v_off_ini = 2185.969 uV, v_off_fin = 2168.282 uV 14:11:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.059 uVs 14:11:05 Integrated Voltage Measurement... 14:11:14 Voltage Offset Correction: v_off_ini = 2197.337 uV, v_off_fin = 2213.048 uV 14:11:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.833 uVs 14:11:16 I2X Average and RMS of Measurements VT = -7.167 +- 9.892 uVs I2X = 0.659 +- 0.910 uTm^2 14:11:18 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:11:21 Integrated Voltage Measurement... 14:11:30 Voltage Offset Correction: v_off_ini = 2196.476 uV, v_off_fin = 2196.929 uV 14:11:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -274.623 uVs 14:11:30 Integrated Voltage Measurement... 14:11:39 Voltage Offset Correction: v_off_ini = 2197.779 uV, v_off_fin = 2173.972 uV 14:11:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 254.932 uVs 14:11:39 Integrated Voltage Measurement... 14:11:48 Voltage Offset Correction: v_off_ini = 2159.645 uV, v_off_fin = 2152.511 uV 14:11:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -247.679 uVs 14:11:48 Integrated Voltage Measurement... 14:11:57 Voltage Offset Correction: v_off_ini = 2172.236 uV, v_off_fin = 2181.230 uV 14:11:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 290.949 uVs 14:11:57 Integrated Voltage Measurement... 14:12:06 Voltage Offset Correction: v_off_ini = 2166.764 uV, v_off_fin = 2162.580 uV 14:12:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.665 uVs 14:12:06 Integrated Voltage Measurement... 14:12:15 Voltage Offset Correction: v_off_ini = 2159.760 uV, v_off_fin = 2160.580 uV 14:12:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 263.115 uVs 14:12:18 I2Y Average and RMS of Measurements VT = -262.827 +- 6.247 uVs I2Y = -24.180 +- 0.575 uTm^2 14:12:22 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:12:26 Integrated Voltage Measurement... 14:12:35 Voltage Offset Correction: v_off_ini = 2203.225 uV, v_off_fin = 2190.571 uV 14:12:35 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.726 uVs 14:12:35 Integrated Voltage Measurement... 14:12:44 Voltage Offset Correction: v_off_ini = 2187.961 uV, v_off_fin = 2202.908 uV 14:12:44 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 31.944 uVs 14:12:44 Integrated Voltage Measurement... 14:12:53 Voltage Offset Correction: v_off_ini = 2215.330 uV, v_off_fin = 2195.549 uV 14:12:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -46.918 uVs 14:12:53 Integrated Voltage Measurement... 14:13:02 Voltage Offset Correction: v_off_ini = 2195.406 uV, v_off_fin = 2208.220 uV 14:13:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 57.353 uVs 14:13:02 Integrated Voltage Measurement... 14:13:11 Voltage Offset Correction: v_off_ini = 2203.443 uV, v_off_fin = 2205.131 uV 14:13:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -31.014 uVs 14:13:11 Integrated Voltage Measurement... 14:13:20 Voltage Offset Correction: v_off_ini = 2213.307 uV, v_off_fin = 2207.528 uV 14:13:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 1.145 uVs 14:13:24 I1X Average and RMS of Measurements VT = -36.183 +- 15.010 uVs I1X = 7.237 +- 3.002 uTm 14:13:27 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:13:31 Integrated Voltage Measurement... 14:13:40 Voltage Offset Correction: v_off_ini = 2205.793 uV, v_off_fin = 2185.959 uV 14:13:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -245.924 uVs 14:13:40 Integrated Voltage Measurement... 14:13:49 Voltage Offset Correction: v_off_ini = 2215.949 uV, v_off_fin = 2235.342 uV 14:13:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 241.195 uVs 14:13:49 Integrated Voltage Measurement... 14:13:58 Voltage Offset Correction: v_off_ini = 2186.865 uV, v_off_fin = 2207.654 uV 14:13:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -223.493 uVs 14:13:58 Integrated Voltage Measurement... 14:14:07 Voltage Offset Correction: v_off_ini = 2229.179 uV, v_off_fin = 2230.025 uV 14:14:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.983 uVs 14:14:07 Integrated Voltage Measurement... 14:14:16 Voltage Offset Correction: v_off_ini = 2224.394 uV, v_off_fin = 2193.979 uV 14:14:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -249.720 uVs 14:14:16 Integrated Voltage Measurement... 14:14:25 Voltage Offset Correction: v_off_ini = 2217.671 uV, v_off_fin = 2214.870 uV 14:14:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 248.509 uVs 14:14:29 I1Y Average and RMS of Measurements VT = -239.471 +- 9.972 uVs I1Y = -47.894 +- 1.994 uTm 14:14:32 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:14:34 Integrated Voltage Measurement... 14:14:43 Voltage Offset Correction: v_off_ini = 2208.864 uV, v_off_fin = 2177.544 uV 14:14:43 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.637 uVs 14:14:43 Integrated Voltage Measurement... 14:14:52 Voltage Offset Correction: v_off_ini = 2202.728 uV, v_off_fin = 2199.133 uV 14:14:52 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -0.698 uVs 14:14:52 Integrated Voltage Measurement... 14:15:01 Voltage Offset Correction: v_off_ini = 2194.512 uV, v_off_fin = 2186.018 uV 14:15:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -1.083 uVs 14:15:01 Integrated Voltage Measurement... 14:15:10 Voltage Offset Correction: v_off_ini = 2192.761 uV, v_off_fin = 2213.747 uV 14:15:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 17.614 uVs 14:15:10 Integrated Voltage Measurement... 14:15:19 Voltage Offset Correction: v_off_ini = 2196.674 uV, v_off_fin = 2196.193 uV 14:15:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -7.606 uVs 14:15:19 Integrated Voltage Measurement... 14:15:28 Voltage Offset Correction: v_off_ini = 2198.004 uV, v_off_fin = 2218.003 uV 14:15:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.255 uVs 14:15:31 I2X Average and RMS of Measurements VT = -7.665 +- 5.956 uVs I2X = 0.705 +- 0.548 uTm^2 14:15:33 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:15:36 Integrated Voltage Measurement... 14:15:45 Voltage Offset Correction: v_off_ini = 2204.531 uV, v_off_fin = 2197.110 uV 14:15:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -278.351 uVs 14:15:45 Integrated Voltage Measurement... 14:15:54 Voltage Offset Correction: v_off_ini = 2202.125 uV, v_off_fin = 2202.463 uV 14:15:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 259.178 uVs 14:15:54 Integrated Voltage Measurement... 14:16:03 Voltage Offset Correction: v_off_ini = 2192.029 uV, v_off_fin = 2178.273 uV 14:16:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -251.711 uVs 14:16:03 Integrated Voltage Measurement... 14:16:12 Voltage Offset Correction: v_off_ini = 2189.346 uV, v_off_fin = 2180.561 uV 14:16:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 276.313 uVs 14:16:12 Integrated Voltage Measurement... 14:16:21 Voltage Offset Correction: v_off_ini = 2209.144 uV, v_off_fin = 2176.486 uV 14:16:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -291.875 uVs 14:16:21 Integrated Voltage Measurement... 14:16:30 Voltage Offset Correction: v_off_ini = 2190.616 uV, v_off_fin = 2180.033 uV 14:16:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.018 uVs 14:16:32 I2Y Average and RMS of Measurements VT = -265.574 +- 2.256 uVs I2Y = -24.433 +- 0.208 uTm^2 14:16:36 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:16:41 Integrated Voltage Measurement... 14:16:50 Voltage Offset Correction: v_off_ini = 2187.836 uV, v_off_fin = 2183.493 uV 14:16:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -49.616 uVs 14:16:50 Integrated Voltage Measurement... 14:16:59 Voltage Offset Correction: v_off_ini = 2192.297 uV, v_off_fin = 2184.636 uV 14:16:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.168 uVs 14:16:59 Integrated Voltage Measurement... 14:17:08 Voltage Offset Correction: v_off_ini = 2188.627 uV, v_off_fin = 2165.969 uV 14:17:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -28.712 uVs 14:17:08 Integrated Voltage Measurement... 14:17:17 Voltage Offset Correction: v_off_ini = 2169.719 uV, v_off_fin = 2178.464 uV 14:17:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 32.339 uVs 14:17:17 Integrated Voltage Measurement... 14:17:26 Voltage Offset Correction: v_off_ini = 2175.146 uV, v_off_fin = 2185.318 uV 14:17:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -12.859 uVs 14:17:26 Integrated Voltage Measurement... 14:17:35 Voltage Offset Correction: v_off_ini = 2176.326 uV, v_off_fin = 2172.360 uV 14:17:35 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 17.071 uVs 14:17:39 I1X Average and RMS of Measurements VT = -31.127 +- 13.449 uVs I1X = 6.226 +- 2.690 uTm 14:17:41 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:17:46 Integrated Voltage Measurement... 14:17:55 Voltage Offset Correction: v_off_ini = 2172.083 uV, v_off_fin = 2179.935 uV 14:17:55 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -229.950 uVs 14:17:55 Integrated Voltage Measurement... 14:18:04 Voltage Offset Correction: v_off_ini = 2194.949 uV, v_off_fin = 2196.167 uV 14:18:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 213.858 uVs 14:18:04 Integrated Voltage Measurement... 14:18:13 Voltage Offset Correction: v_off_ini = 2169.119 uV, v_off_fin = 2162.804 uV 14:18:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -220.310 uVs 14:18:13 Integrated Voltage Measurement... 14:18:21 Voltage Offset Correction: v_off_ini = 2167.203 uV, v_off_fin = 2173.615 uV 14:18:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 227.603 uVs 14:18:22 Integrated Voltage Measurement... 14:18:30 Voltage Offset Correction: v_off_ini = 2156.812 uV, v_off_fin = 2153.225 uV 14:18:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.854 uVs 14:18:31 Integrated Voltage Measurement... 14:18:39 Voltage Offset Correction: v_off_ini = 2170.461 uV, v_off_fin = 2168.556 uV 14:18:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 223.785 uVs 14:18:44 I1Y Average and RMS of Measurements VT = -222.227 +- 1.301 uVs I1Y = -44.445 +- 0.260 uTm 14:18:46 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:18:49 Integrated Voltage Measurement... 14:18:58 Voltage Offset Correction: v_off_ini = 2172.019 uV, v_off_fin = 2168.924 uV 14:18:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.566 uVs 14:18:58 Integrated Voltage Measurement... 14:19:07 Voltage Offset Correction: v_off_ini = 2173.832 uV, v_off_fin = 2170.274 uV 14:19:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -5.641 uVs 14:19:07 Integrated Voltage Measurement... 14:19:16 Voltage Offset Correction: v_off_ini = 2146.913 uV, v_off_fin = 2135.936 uV 14:19:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 6.882 uVs 14:19:16 Integrated Voltage Measurement... 14:19:25 Voltage Offset Correction: v_off_ini = 2144.448 uV, v_off_fin = 2136.782 uV 14:19:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -12.900 uVs 14:19:25 Integrated Voltage Measurement... 14:19:34 Voltage Offset Correction: v_off_ini = 2134.771 uV, v_off_fin = 2150.342 uV 14:19:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -12.852 uVs 14:19:34 Integrated Voltage Measurement... 14:19:43 Voltage Offset Correction: v_off_ini = 2170.584 uV, v_off_fin = 2151.941 uV 14:19:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -8.869 uVs 14:19:45 I2X Average and RMS of Measurements VT = 4.168 +- 4.861 uVs I2X = -0.383 +- 0.447 uTm^2 14:19:48 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:19:50 Integrated Voltage Measurement... 14:19:59 Voltage Offset Correction: v_off_ini = 2130.055 uV, v_off_fin = 2161.969 uV 14:19:59 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -238.799 uVs 14:19:59 Integrated Voltage Measurement... 14:20:08 Voltage Offset Correction: v_off_ini = 2160.883 uV, v_off_fin = 2160.800 uV 14:20:08 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 251.720 uVs 14:20:08 Integrated Voltage Measurement... 14:20:17 Voltage Offset Correction: v_off_ini = 2149.568 uV, v_off_fin = 2159.383 uV 14:20:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.878 uVs 14:20:17 Integrated Voltage Measurement... 14:20:26 Voltage Offset Correction: v_off_ini = 2163.172 uV, v_off_fin = 2162.347 uV 14:20:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 250.892 uVs 14:20:27 Integrated Voltage Measurement... 14:20:35 Voltage Offset Correction: v_off_ini = 2159.338 uV, v_off_fin = 2164.212 uV 14:20:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -226.372 uVs 14:20:36 Integrated Voltage Measurement... 14:20:45 Voltage Offset Correction: v_off_ini = 2160.478 uV, v_off_fin = 2163.808 uV 14:20:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 266.010 uVs 14:20:47 I2Y Average and RMS of Measurements VT = -245.778 +- 0.388 uVs I2Y = -22.612 +- 0.036 uTm^2 14:20:51 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:20:55 Integrated Voltage Measurement... 14:21:04 Voltage Offset Correction: v_off_ini = 2160.648 uV, v_off_fin = 2160.033 uV 14:21:04 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -23.898 uVs 14:21:04 Integrated Voltage Measurement... 14:21:13 Voltage Offset Correction: v_off_ini = 2133.740 uV, v_off_fin = 2146.519 uV 14:21:13 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 24.586 uVs 14:21:13 Integrated Voltage Measurement... 14:21:22 Voltage Offset Correction: v_off_ini = 2158.689 uV, v_off_fin = 2146.858 uV 14:21:22 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -38.925 uVs 14:21:22 Integrated Voltage Measurement... 14:21:31 Voltage Offset Correction: v_off_ini = 2178.572 uV, v_off_fin = 2168.430 uV 14:21:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = -4.959 uVs 14:21:31 Integrated Voltage Measurement... 14:21:40 Voltage Offset Correction: v_off_ini = 2182.488 uV, v_off_fin = 2166.884 uV 14:21:40 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -4.003 uVs 14:21:40 Integrated Voltage Measurement... 14:21:49 Voltage Offset Correction: v_off_ini = 2178.637 uV, v_off_fin = 2186.426 uV 14:21:49 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 6.761 uVs 14:21:53 I1X Average and RMS of Measurements VT = -15.536 +- 7.767 uVs I1X = 3.107 +- 1.554 uTm 14:21:56 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:22:00 Integrated Voltage Measurement... 14:22:09 Voltage Offset Correction: v_off_ini = 2197.723 uV, v_off_fin = 2182.596 uV 14:22:09 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -231.998 uVs 14:22:09 Integrated Voltage Measurement... 14:22:18 Voltage Offset Correction: v_off_ini = 2196.883 uV, v_off_fin = 2228.597 uV 14:22:18 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 219.169 uVs 14:22:18 Integrated Voltage Measurement... 14:22:27 Voltage Offset Correction: v_off_ini = 2194.725 uV, v_off_fin = 2190.049 uV 14:22:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -199.978 uVs 14:22:27 Integrated Voltage Measurement... 14:22:36 Voltage Offset Correction: v_off_ini = 2182.578 uV, v_off_fin = 2195.690 uV 14:22:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 230.681 uVs 14:22:36 Integrated Voltage Measurement... 14:22:45 Voltage Offset Correction: v_off_ini = 2193.527 uV, v_off_fin = 2160.555 uV 14:22:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -198.932 uVs 14:22:45 Integrated Voltage Measurement... 14:22:54 Voltage Offset Correction: v_off_ini = 2181.660 uV, v_off_fin = 2189.785 uV 14:22:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 231.456 uVs 14:22:58 I1Y Average and RMS of Measurements VT = -218.702 +- 4.866 uVs I1Y = -43.738 +- 0.975 uTm 14:23:01 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:23:03 Integrated Voltage Measurement... 14:23:12 Voltage Offset Correction: v_off_ini = 2194.700 uV, v_off_fin = 2185.504 uV 14:23:12 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 4.756 uVs 14:23:12 Integrated Voltage Measurement... 14:23:21 Voltage Offset Correction: v_off_ini = 2200.650 uV, v_off_fin = 2199.192 uV 14:23:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.689 uVs 14:23:21 Integrated Voltage Measurement... 14:23:30 Voltage Offset Correction: v_off_ini = 2188.213 uV, v_off_fin = 2196.596 uV 14:23:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 2.957 uVs 14:23:30 Integrated Voltage Measurement... 14:23:39 Voltage Offset Correction: v_off_ini = 2236.507 uV, v_off_fin = 2222.461 uV 14:23:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.141 uVs 14:23:40 Integrated Voltage Measurement... 14:23:48 Voltage Offset Correction: v_off_ini = 2248.810 uV, v_off_fin = 2226.049 uV 14:23:49 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -19.512 uVs 14:23:49 Integrated Voltage Measurement... 14:23:58 Voltage Offset Correction: v_off_ini = 2230.923 uV, v_off_fin = 2239.389 uV 14:23:58 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 22.680 uVs 14:24:00 I2X Average and RMS of Measurements VT = -13.718 +- 8.006 uVs I2X = 1.262 +- 0.737 uTm^2 14:24:02 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 14:24:05 Integrated Voltage Measurement... 14:24:14 Voltage Offset Correction: v_off_ini = 2255.741 uV, v_off_fin = 2243.346 uV 14:24:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -245.750 uVs 14:24:14 Integrated Voltage Measurement... 14:24:23 Voltage Offset Correction: v_off_ini = 2225.000 uV, v_off_fin = 2227.053 uV 14:24:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 245.658 uVs 14:24:23 Integrated Voltage Measurement... 14:24:32 Voltage Offset Correction: v_off_ini = 2239.142 uV, v_off_fin = 2230.638 uV 14:24:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -243.628 uVs 14:24:32 Integrated Voltage Measurement... 14:24:41 Voltage Offset Correction: v_off_ini = 2238.298 uV, v_off_fin = 2243.811 uV 14:24:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 224.147 uVs 14:24:41 Integrated Voltage Measurement... 14:24:50 Voltage Offset Correction: v_off_ini = 2233.213 uV, v_off_fin = 2215.119 uV 14:24:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.239 uVs 14:24:50 Integrated Voltage Measurement... 14:24:59 Voltage Offset Correction: v_off_ini = 2213.575 uV, v_off_fin = 2226.887 uV 14:24:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 236.494 uVs 14:25:02 I2Y Average and RMS of Measurements VT = -232.486 +- 11.407 uVs I2Y = -21.389 +- 1.049 uTm^2 14:25:06 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:25:10 Integrated Voltage Measurement... 14:25:19 Voltage Offset Correction: v_off_ini = 2241.887 uV, v_off_fin = 2230.873 uV 14:25:19 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -36.637 uVs 14:25:19 Integrated Voltage Measurement... 14:25:28 Voltage Offset Correction: v_off_ini = 2234.929 uV, v_off_fin = 2250.607 uV 14:25:28 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 25.659 uVs 14:25:28 Integrated Voltage Measurement... 14:25:37 Voltage Offset Correction: v_off_ini = 2242.892 uV, v_off_fin = 2249.738 uV 14:25:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -32.715 uVs 14:25:37 Integrated Voltage Measurement... 14:25:46 Voltage Offset Correction: v_off_ini = 2223.227 uV, v_off_fin = 2224.876 uV 14:25:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 6.615 uVs 14:25:46 Integrated Voltage Measurement... 14:25:55 Voltage Offset Correction: v_off_ini = 2241.230 uV, v_off_fin = 2235.975 uV 14:25:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -24.297 uVs 14:25:55 Integrated Voltage Measurement... 14:26:04 Voltage Offset Correction: v_off_ini = 2223.535 uV, v_off_fin = 2231.976 uV 14:26:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.081 uVs 14:26:08 I1X Average and RMS of Measurements VT = -25.334 +- 4.689 uVs I1X = 5.067 +- 0.938 uTm 14:26:11 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:26:15 Integrated Voltage Measurement... 14:26:24 Voltage Offset Correction: v_off_ini = 2246.333 uV, v_off_fin = 2229.749 uV 14:26:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -201.968 uVs 14:26:24 Integrated Voltage Measurement... 14:26:33 Voltage Offset Correction: v_off_ini = 2209.367 uV, v_off_fin = 2241.778 uV 14:26:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 201.274 uVs 14:26:33 Integrated Voltage Measurement... 14:26:42 Voltage Offset Correction: v_off_ini = 2243.287 uV, v_off_fin = 2235.923 uV 14:26:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -217.926 uVs 14:26:42 Integrated Voltage Measurement... 14:26:51 Voltage Offset Correction: v_off_ini = 2227.780 uV, v_off_fin = 2253.998 uV 14:26:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 209.733 uVs 14:26:51 Integrated Voltage Measurement... 14:27:00 Voltage Offset Correction: v_off_ini = 2228.605 uV, v_off_fin = 2208.206 uV 14:27:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -214.784 uVs 14:27:00 Integrated Voltage Measurement... 14:27:09 Voltage Offset Correction: v_off_ini = 2213.707 uV, v_off_fin = 2243.452 uV 14:27:09 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 246.677 uVs 14:27:13 I1Y Average and RMS of Measurements VT = -215.394 +- 11.935 uVs I1Y = -43.077 +- 2.387 uTm 14:27:15 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:27:18 Integrated Voltage Measurement... 14:27:27 Voltage Offset Correction: v_off_ini = 2222.487 uV, v_off_fin = 2208.978 uV 14:27:27 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 27.465 uVs 14:27:27 Integrated Voltage Measurement... 14:27:36 Voltage Offset Correction: v_off_ini = 2212.915 uV, v_off_fin = 2218.755 uV 14:27:36 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -7.806 uVs 14:27:36 Integrated Voltage Measurement... 14:27:45 Voltage Offset Correction: v_off_ini = 2243.678 uV, v_off_fin = 2234.630 uV 14:27:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 3.078 uVs 14:27:45 Integrated Voltage Measurement... 14:27:54 Voltage Offset Correction: v_off_ini = 2242.424 uV, v_off_fin = 2259.586 uV 14:27:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -34.203 uVs 14:27:54 Integrated Voltage Measurement... 14:28:03 Voltage Offset Correction: v_off_ini = 2247.118 uV, v_off_fin = 2228.978 uV 14:28:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 8.993 uVs 14:28:03 Integrated Voltage Measurement... 14:28:12 Voltage Offset Correction: v_off_ini = 2209.936 uV, v_off_fin = 2223.138 uV 14:28:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 8.504 uVs 14:28:15 I2X Average and RMS of Measurements VT = 12.174 +- 8.445 uVs I2X = -1.120 +- 0.777 uTm^2 14:28:17 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 14:28:20 Integrated Voltage Measurement... 14:28:29 Voltage Offset Correction: v_off_ini = 2247.429 uV, v_off_fin = 2251.756 uV 14:28:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -204.103 uVs 14:28:29 Integrated Voltage Measurement... 14:28:38 Voltage Offset Correction: v_off_ini = 2248.942 uV, v_off_fin = 2239.008 uV 14:28:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 246.166 uVs 14:28:38 Integrated Voltage Measurement... 14:28:47 Voltage Offset Correction: v_off_ini = 2236.101 uV, v_off_fin = 2245.258 uV 14:28:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -213.680 uVs 14:28:47 Integrated Voltage Measurement... 14:28:56 Voltage Offset Correction: v_off_ini = 2251.222 uV, v_off_fin = 2244.982 uV 14:28:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 202.223 uVs 14:28:56 Integrated Voltage Measurement... 14:29:05 Voltage Offset Correction: v_off_ini = 2247.898 uV, v_off_fin = 2243.335 uV 14:29:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -227.162 uVs 14:29:05 Integrated Voltage Measurement... 14:29:14 Voltage Offset Correction: v_off_ini = 2257.948 uV, v_off_fin = 2276.010 uV 14:29:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 223.982 uVs 14:29:16 I2Y Average and RMS of Measurements VT = -219.553 +- 8.205 uVs I2Y = -20.199 +- 0.755 uTm^2 14:31:40 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:31:44 Integrated Voltage Measurement... 14:31:53 Voltage Offset Correction: v_off_ini = 2236.496 uV, v_off_fin = 2233.699 uV 14:31:53 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -30.132 uVs 14:31:53 Integrated Voltage Measurement... 14:32:02 Voltage Offset Correction: v_off_ini = 2216.598 uV, v_off_fin = 2227.026 uV 14:32:02 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = 72.507 uVs 14:32:02 Integrated Voltage Measurement... 14:32:11 Voltage Offset Correction: v_off_ini = 2223.732 uV, v_off_fin = 2213.784 uV 14:32:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -67.206 uVs 14:32:11 Integrated Voltage Measurement... 14:32:20 Voltage Offset Correction: v_off_ini = 2225.808 uV, v_off_fin = 2257.792 uV 14:32:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 52.441 uVs 14:32:20 Integrated Voltage Measurement... 14:32:29 Voltage Offset Correction: v_off_ini = 2244.249 uV, v_off_fin = 2254.084 uV 14:32:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.876 uVs 14:32:29 Integrated Voltage Measurement... 14:32:38 Voltage Offset Correction: v_off_ini = 2255.421 uV, v_off_fin = 2261.502 uV 14:32:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.568 uVs 14:32:42 I1X Average and RMS of Measurements VT = -54.622 +- 3.723 uVs I1X = 10.925 +- 0.744 uTm 14:32:45 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:32:49 Integrated Voltage Measurement... 14:32:58 Voltage Offset Correction: v_off_ini = 2236.480 uV, v_off_fin = 2237.644 uV 14:32:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.4999 mm VT = -171.088 uVs 14:32:58 Integrated Voltage Measurement... 14:33:07 Voltage Offset Correction: v_off_ini = 2230.974 uV, v_off_fin = 2241.717 uV 14:33:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 193.072 uVs 14:33:07 Integrated Voltage Measurement... 14:33:16 Voltage Offset Correction: v_off_ini = 2233.527 uV, v_off_fin = 2232.280 uV 14:33:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.820 uVs 14:33:16 Integrated Voltage Measurement... 14:33:25 Voltage Offset Correction: v_off_ini = 2242.376 uV, v_off_fin = 2256.583 uV 14:33:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 169.273 uVs 14:33:25 Integrated Voltage Measurement... 14:33:34 Voltage Offset Correction: v_off_ini = 2249.271 uV, v_off_fin = 2249.501 uV 14:33:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.053 uVs 14:33:34 Integrated Voltage Measurement... 14:33:43 Voltage Offset Correction: v_off_ini = 2255.704 uV, v_off_fin = 2250.282 uV 14:33:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.488 uVs 14:33:47 I1Y Average and RMS of Measurements VT = -178.966 +- 5.269 uVs I1Y = -35.794 +- 1.054 uTm 14:33:52 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:33:55 Integrated Voltage Measurement... 14:34:04 Voltage Offset Correction: v_off_ini = 2236.188 uV, v_off_fin = 2241.122 uV 14:34:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -15.302 uVs 14:34:04 Integrated Voltage Measurement... 14:34:13 Voltage Offset Correction: v_off_ini = 2247.224 uV, v_off_fin = 2273.251 uV 14:34:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 70.597 uVs 14:34:13 Integrated Voltage Measurement... 14:34:22 Voltage Offset Correction: v_off_ini = 2259.598 uV, v_off_fin = 2267.461 uV 14:34:22 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -63.276 uVs 14:34:22 Integrated Voltage Measurement... 14:34:31 Voltage Offset Correction: v_off_ini = 2276.504 uV, v_off_fin = 2251.000 uV 14:34:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.007 uVs 14:34:31 Integrated Voltage Measurement... 14:34:40 Voltage Offset Correction: v_off_ini = 2262.720 uV, v_off_fin = 2250.456 uV 14:34:40 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -54.669 uVs 14:34:40 Integrated Voltage Measurement... 14:34:49 Voltage Offset Correction: v_off_ini = 2272.954 uV, v_off_fin = 2264.791 uV 14:34:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 51.351 uVs 14:34:51 I2X Average and RMS of Measurements VT = -50.367 +- 5.317 uVs I2X = 4.634 +- 0.489 uTm^2 14:34:56 Wire Position: X0 = -2.0000 mm, Y0 = 0.0000 mm 14:34:59 Integrated Voltage Measurement... 14:35:08 Voltage Offset Correction: v_off_ini = 2258.482 uV, v_off_fin = 2235.793 uV 14:35:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.272 uVs 14:35:08 Integrated Voltage Measurement... 14:35:17 Voltage Offset Correction: v_off_ini = 2222.008 uV, v_off_fin = 2208.219 uV 14:35:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 169.133 uVs 14:35:17 Integrated Voltage Measurement... 14:35:26 Voltage Offset Correction: v_off_ini = 2213.526 uV, v_off_fin = 2223.513 uV 14:35:26 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -163.493 uVs 14:35:26 Integrated Voltage Measurement... 14:35:35 Voltage Offset Correction: v_off_ini = 2188.427 uV, v_off_fin = 2182.606 uV 14:35:35 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 200.594 uVs 14:35:35 Integrated Voltage Measurement... 14:35:44 Voltage Offset Correction: v_off_ini = 2214.948 uV, v_off_fin = 2194.703 uV 14:35:44 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -177.903 uVs 14:35:44 Integrated Voltage Measurement... 14:35:53 Voltage Offset Correction: v_off_ini = 2188.268 uV, v_off_fin = 2212.919 uV 14:35:53 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 203.551 uVs 14:35:56 I2Y Average and RMS of Measurements VT = -184.158 +- 4.742 uVs I2Y = -16.943 +- 0.436 uTm^2 14:36:00 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:36:04 Integrated Voltage Measurement... 14:36:13 Voltage Offset Correction: v_off_ini = 2196.021 uV, v_off_fin = 2194.144 uV 14:36:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -72.458 uVs 14:36:13 Integrated Voltage Measurement... 14:36:22 Voltage Offset Correction: v_off_ini = 2195.459 uV, v_off_fin = 2227.226 uV 14:36:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 70.728 uVs 14:36:22 Integrated Voltage Measurement... 14:36:31 Voltage Offset Correction: v_off_ini = 2225.718 uV, v_off_fin = 2207.325 uV 14:36:31 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -42.290 uVs 14:36:32 Integrated Voltage Measurement... 14:36:40 Voltage Offset Correction: v_off_ini = 2195.126 uV, v_off_fin = 2211.956 uV 14:36:40 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 25.844 uVs 14:36:41 Integrated Voltage Measurement... 14:36:49 Voltage Offset Correction: v_off_ini = 2208.223 uV, v_off_fin = 2223.621 uV 14:36:49 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -54.246 uVs 14:36:50 Integrated Voltage Measurement... 14:36:58 Voltage Offset Correction: v_off_ini = 2232.611 uV, v_off_fin = 2247.802 uV 14:36:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 74.576 uVs 14:37:03 I1X Average and RMS of Measurements VT = -56.690 +- 16.263 uVs I1X = 11.338 +- 3.253 uTm 14:37:05 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:37:09 Integrated Voltage Measurement... 14:37:18 Voltage Offset Correction: v_off_ini = 2255.239 uV, v_off_fin = 2236.820 uV 14:37:18 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -177.654 uVs 14:37:18 Integrated Voltage Measurement... 14:37:27 Voltage Offset Correction: v_off_ini = 2259.840 uV, v_off_fin = 2258.734 uV 14:37:27 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.727 uVs 14:37:27 Integrated Voltage Measurement... 14:37:36 Voltage Offset Correction: v_off_ini = 2232.229 uV, v_off_fin = 2239.259 uV 14:37:36 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.951 uVs 14:37:36 Integrated Voltage Measurement... 14:37:45 Voltage Offset Correction: v_off_ini = 2256.195 uV, v_off_fin = 2274.730 uV 14:37:45 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.557 uVs 14:37:45 Integrated Voltage Measurement... 14:37:54 Voltage Offset Correction: v_off_ini = 2232.086 uV, v_off_fin = 2224.026 uV 14:37:54 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -190.277 uVs 14:37:54 Integrated Voltage Measurement... 14:38:03 Voltage Offset Correction: v_off_ini = 2229.544 uV, v_off_fin = 2229.456 uV 14:38:03 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.220 uVs 14:38:08 I1Y Average and RMS of Measurements VT = -188.231 +- 6.308 uVs I1Y = -37.646 +- 1.262 uTm 14:38:13 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:38:15 Integrated Voltage Measurement... 14:38:24 Voltage Offset Correction: v_off_ini = 2248.531 uV, v_off_fin = 2246.790 uV 14:38:24 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -32.856 uVs 14:38:24 Integrated Voltage Measurement... 14:38:33 Voltage Offset Correction: v_off_ini = 2243.217 uV, v_off_fin = 2240.065 uV 14:38:33 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 21.216 uVs 14:38:33 Integrated Voltage Measurement... 14:38:42 Voltage Offset Correction: v_off_ini = 2255.684 uV, v_off_fin = 2221.796 uV 14:38:42 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -41.275 uVs 14:38:42 Integrated Voltage Measurement... 14:38:51 Voltage Offset Correction: v_off_ini = 2223.073 uV, v_off_fin = 2229.662 uV 14:38:51 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.705 uVs 14:38:51 Integrated Voltage Measurement... 14:39:00 Voltage Offset Correction: v_off_ini = 2241.900 uV, v_off_fin = 2229.206 uV 14:39:00 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -44.902 uVs 14:39:00 Integrated Voltage Measurement... 14:39:09 Voltage Offset Correction: v_off_ini = 2250.147 uV, v_off_fin = 2269.191 uV 14:39:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 32.070 uVs 14:39:12 I2X Average and RMS of Measurements VT = -36.171 +- 6.716 uVs I2X = 3.328 +- 0.618 uTm^2 14:39:17 Wire Position: X0 = -1.0000 mm, Y0 = 0.0000 mm 14:39:20 Integrated Voltage Measurement... 14:39:28 Voltage Offset Correction: v_off_ini = 2247.719 uV, v_off_fin = 2257.369 uV 14:39:29 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -168.825 uVs 14:39:29 Integrated Voltage Measurement... 14:39:38 Voltage Offset Correction: v_off_ini = 2255.940 uV, v_off_fin = 2260.518 uV 14:39:38 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.914 uVs 14:39:38 Integrated Voltage Measurement... 14:39:47 Voltage Offset Correction: v_off_ini = 2241.480 uV, v_off_fin = 2267.880 uV 14:39:47 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -166.584 uVs 14:39:47 Integrated Voltage Measurement... 14:39:56 Voltage Offset Correction: v_off_ini = 2263.494 uV, v_off_fin = 2278.876 uV 14:39:56 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.420 uVs 14:39:56 Integrated Voltage Measurement... 14:40:05 Voltage Offset Correction: v_off_ini = 2278.187 uV, v_off_fin = 2273.123 uV 14:40:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -184.930 uVs 14:40:05 Integrated Voltage Measurement... 14:40:14 Voltage Offset Correction: v_off_ini = 2260.762 uV, v_off_fin = 2270.535 uV 14:40:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 179.098 uVs 14:40:16 I2Y Average and RMS of Measurements VT = -176.962 +- 4.541 uVs I2Y = -16.280 +- 0.418 uTm^2 14:40:21 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:40:25 Integrated Voltage Measurement... 14:40:34 Voltage Offset Correction: v_off_ini = 2262.120 uV, v_off_fin = 2259.187 uV 14:40:34 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -50.495 uVs 14:40:34 Integrated Voltage Measurement... 14:40:43 Voltage Offset Correction: v_off_ini = 2263.113 uV, v_off_fin = 2277.046 uV 14:40:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 51.914 uVs 14:40:43 Integrated Voltage Measurement... 14:40:52 Voltage Offset Correction: v_off_ini = 2278.216 uV, v_off_fin = 2291.733 uV 14:40:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.656 uVs 14:40:52 Integrated Voltage Measurement... 14:41:01 Voltage Offset Correction: v_off_ini = 2277.835 uV, v_off_fin = 2305.750 uV 14:41:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 77.651 uVs 14:41:01 Integrated Voltage Measurement... 14:41:10 Voltage Offset Correction: v_off_ini = 2301.388 uV, v_off_fin = 2302.618 uV 14:41:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -62.881 uVs 14:41:10 Integrated Voltage Measurement... 14:41:19 Voltage Offset Correction: v_off_ini = 2305.866 uV, v_off_fin = 2321.023 uV 14:41:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 46.791 uVs 14:41:23 I1X Average and RMS of Measurements VT = -55.898 +- 4.331 uVs I1X = 11.180 +- 0.866 uTm 14:41:26 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:41:30 Integrated Voltage Measurement... 14:41:39 Voltage Offset Correction: v_off_ini = 2299.300 uV, v_off_fin = 2296.634 uV 14:41:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -204.104 uVs 14:41:39 Integrated Voltage Measurement... 14:41:48 Voltage Offset Correction: v_off_ini = 2294.364 uV, v_off_fin = 2296.734 uV 14:41:48 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 192.343 uVs 14:41:48 Integrated Voltage Measurement... 14:41:57 Voltage Offset Correction: v_off_ini = 2287.697 uV, v_off_fin = 2288.187 uV 14:41:57 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.976 uVs 14:41:57 Integrated Voltage Measurement... 14:42:06 Voltage Offset Correction: v_off_ini = 2282.023 uV, v_off_fin = 2281.161 uV 14:42:06 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 196.765 uVs 14:42:06 Integrated Voltage Measurement... 14:42:15 Voltage Offset Correction: v_off_ini = 2280.210 uV, v_off_fin = 2262.286 uV 14:42:15 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -173.026 uVs 14:42:15 Integrated Voltage Measurement... 14:42:24 Voltage Offset Correction: v_off_ini = 2271.536 uV, v_off_fin = 2266.585 uV 14:42:24 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.051 uVs 14:42:28 I1Y Average and RMS of Measurements VT = -191.877 +- 4.520 uVs I1Y = -38.375 +- 0.904 uTm 14:42:33 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:42:36 Integrated Voltage Measurement... 14:42:45 Voltage Offset Correction: v_off_ini = 2268.073 uV, v_off_fin = 2260.678 uV 14:42:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.590 uVs 14:42:45 Integrated Voltage Measurement... 14:42:54 Voltage Offset Correction: v_off_ini = 2260.596 uV, v_off_fin = 2264.633 uV 14:42:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 35.836 uVs 14:42:54 Integrated Voltage Measurement... 14:43:03 Voltage Offset Correction: v_off_ini = 2273.995 uV, v_off_fin = 2255.878 uV 14:43:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.790 uVs 14:43:03 Integrated Voltage Measurement... 14:43:12 Voltage Offset Correction: v_off_ini = 2264.618 uV, v_off_fin = 2280.770 uV 14:43:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.119 uVs 14:43:12 Integrated Voltage Measurement... 14:43:21 Voltage Offset Correction: v_off_ini = 2269.333 uV, v_off_fin = 2250.268 uV 14:43:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -53.295 uVs 14:43:21 Integrated Voltage Measurement... 14:43:30 Voltage Offset Correction: v_off_ini = 2273.818 uV, v_off_fin = 2283.031 uV 14:43:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.184 uVs 14:43:32 I2X Average and RMS of Measurements VT = -38.136 +- 7.163 uVs I2X = 3.508 +- 0.659 uTm^2 14:43:37 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 14:43:40 Integrated Voltage Measurement... 14:43:49 Voltage Offset Correction: v_off_ini = 2252.412 uV, v_off_fin = 2245.000 uV 14:43:49 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -193.461 uVs 14:43:49 Integrated Voltage Measurement... 14:43:58 Voltage Offset Correction: v_off_ini = 2262.228 uV, v_off_fin = 2264.306 uV 14:43:58 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 182.174 uVs 14:43:58 Integrated Voltage Measurement... 14:44:07 Voltage Offset Correction: v_off_ini = 2267.930 uV, v_off_fin = 2266.525 uV 14:44:07 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -182.239 uVs 14:44:07 Integrated Voltage Measurement... 14:44:16 Voltage Offset Correction: v_off_ini = 2282.356 uV, v_off_fin = 2281.735 uV 14:44:16 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 218.058 uVs 14:44:16 Integrated Voltage Measurement... 14:44:25 Voltage Offset Correction: v_off_ini = 2295.127 uV, v_off_fin = 2294.555 uV 14:44:25 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.978 uVs 14:44:25 Integrated Voltage Measurement... 14:44:34 Voltage Offset Correction: v_off_ini = 2293.163 uV, v_off_fin = 2281.545 uV 14:44:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.225 uVs 14:44:36 I2Y Average and RMS of Measurements VT = -194.856 +- 5.183 uVs I2Y = -17.927 +- 0.477 uTm^2 14:44:41 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:44:45 Integrated Voltage Measurement... 14:44:54 Voltage Offset Correction: v_off_ini = 2266.065 uV, v_off_fin = 2263.828 uV 14:44:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -11.640 uVs 14:44:54 Integrated Voltage Measurement... 14:45:03 Voltage Offset Correction: v_off_ini = 2262.227 uV, v_off_fin = 2261.507 uV 14:45:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 59.388 uVs 14:45:03 Integrated Voltage Measurement... 14:45:12 Voltage Offset Correction: v_off_ini = 2251.374 uV, v_off_fin = 2249.758 uV 14:45:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -48.042 uVs 14:45:12 Integrated Voltage Measurement... 14:45:21 Voltage Offset Correction: v_off_ini = 2260.879 uV, v_off_fin = 2254.695 uV 14:45:21 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 42.630 uVs 14:45:21 Integrated Voltage Measurement... 14:45:30 Voltage Offset Correction: v_off_ini = 2262.862 uV, v_off_fin = 2254.503 uV 14:45:30 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -44.603 uVs 14:45:30 Integrated Voltage Measurement... 14:45:39 Voltage Offset Correction: v_off_ini = 2239.004 uV, v_off_fin = 2274.132 uV 14:45:39 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 13.170 uVs 14:45:43 I1X Average and RMS of Measurements VT = -36.579 +- 6.758 uVs I1X = 7.316 +- 1.352 uTm 14:45:46 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:45:50 Integrated Voltage Measurement... 14:45:59 Voltage Offset Correction: v_off_ini = 2243.771 uV, v_off_fin = 2243.106 uV 14:45:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -188.922 uVs 14:45:59 Integrated Voltage Measurement... 14:46:08 Voltage Offset Correction: v_off_ini = 2243.042 uV, v_off_fin = 2236.734 uV 14:46:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.791 uVs 14:46:08 Integrated Voltage Measurement... 14:46:17 Voltage Offset Correction: v_off_ini = 2227.345 uV, v_off_fin = 2214.859 uV 14:46:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.118 uVs 14:46:17 Integrated Voltage Measurement... 14:46:26 Voltage Offset Correction: v_off_ini = 2238.664 uV, v_off_fin = 2253.000 uV 14:46:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.351 uVs 14:46:26 Integrated Voltage Measurement... 14:46:35 Voltage Offset Correction: v_off_ini = 2237.301 uV, v_off_fin = 2230.717 uV 14:46:35 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -195.988 uVs 14:46:35 Integrated Voltage Measurement... 14:46:44 Voltage Offset Correction: v_off_ini = 2237.285 uV, v_off_fin = 2234.674 uV 14:46:44 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 199.135 uVs 14:46:48 I1Y Average and RMS of Measurements VT = -191.884 +- 4.394 uVs I1Y = -38.377 +- 0.879 uTm 14:46:53 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:46:56 Integrated Voltage Measurement... 14:47:05 Voltage Offset Correction: v_off_ini = 2229.328 uV, v_off_fin = 2223.281 uV 14:47:05 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -25.778 uVs 14:47:05 Integrated Voltage Measurement... 14:47:14 Voltage Offset Correction: v_off_ini = 2221.959 uV, v_off_fin = 2209.012 uV 14:47:14 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 52.635 uVs 14:47:14 Integrated Voltage Measurement... 14:47:23 Voltage Offset Correction: v_off_ini = 2205.079 uV, v_off_fin = 2187.997 uV 14:47:23 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.578 uVs 14:47:23 Integrated Voltage Measurement... 14:47:32 Voltage Offset Correction: v_off_ini = 2215.613 uV, v_off_fin = 2214.060 uV 14:47:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 45.826 uVs 14:47:32 Integrated Voltage Measurement... 14:47:41 Voltage Offset Correction: v_off_ini = 2209.725 uV, v_off_fin = 2206.573 uV 14:47:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -28.085 uVs 14:47:41 Integrated Voltage Measurement... 14:47:50 Voltage Offset Correction: v_off_ini = 2227.498 uV, v_off_fin = 2225.245 uV 14:47:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.227 uVs 14:47:53 I2X Average and RMS of Measurements VT = -34.021 +- 3.720 uVs I2X = 3.130 +- 0.342 uTm^2 14:47:58 Wire Position: X0 = 1.0000 mm, Y0 = 0.0000 mm 14:48:00 Integrated Voltage Measurement... 14:48:09 Voltage Offset Correction: v_off_ini = 2240.593 uV, v_off_fin = 2242.931 uV 14:48:09 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -215.250 uVs 14:48:09 Integrated Voltage Measurement... 14:48:18 Voltage Offset Correction: v_off_ini = 2246.284 uV, v_off_fin = 2245.053 uV 14:48:18 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 194.552 uVs 14:48:18 Integrated Voltage Measurement... 14:48:27 Voltage Offset Correction: v_off_ini = 2229.853 uV, v_off_fin = 2242.423 uV 14:48:27 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -165.402 uVs 14:48:27 Integrated Voltage Measurement... 14:48:36 Voltage Offset Correction: v_off_ini = 2217.545 uV, v_off_fin = 2209.556 uV 14:48:36 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 177.762 uVs 14:48:36 Integrated Voltage Measurement... 14:48:45 Voltage Offset Correction: v_off_ini = 2216.591 uV, v_off_fin = 2203.046 uV 14:48:45 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -171.711 uVs 14:48:45 Integrated Voltage Measurement... 14:48:54 Voltage Offset Correction: v_off_ini = 2208.045 uV, v_off_fin = 2212.569 uV 14:48:54 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 180.307 uVs 14:48:57 I2Y Average and RMS of Measurements VT = -184.164 +- 14.774 uVs I2Y = -16.943 +- 1.359 uTm^2 14:49:01 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:49:06 Integrated Voltage Measurement... 14:49:15 Voltage Offset Correction: v_off_ini = 2208.642 uV, v_off_fin = 2191.385 uV 14:49:15 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -51.389 uVs 14:49:15 Integrated Voltage Measurement... 14:49:24 Voltage Offset Correction: v_off_ini = 2179.036 uV, v_off_fin = 2189.451 uV 14:49:24 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 72.823 uVs 14:49:24 Integrated Voltage Measurement... 14:49:33 Voltage Offset Correction: v_off_ini = 2204.026 uV, v_off_fin = 2206.675 uV 14:49:33 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -90.648 uVs 14:49:33 Integrated Voltage Measurement... 14:49:42 Voltage Offset Correction: v_off_ini = 2190.395 uV, v_off_fin = 2189.643 uV 14:49:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 49.673 uVs 14:49:42 Integrated Voltage Measurement... 14:49:51 Voltage Offset Correction: v_off_ini = 2198.802 uV, v_off_fin = 2208.375 uV 14:49:51 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -37.219 uVs 14:49:51 Integrated Voltage Measurement... 14:50:00 Voltage Offset Correction: v_off_ini = 2194.276 uV, v_off_fin = 2215.510 uV 14:50:00 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.761 uVs 14:50:04 I1X Average and RMS of Measurements VT = -56.586 +- 13.897 uVs I1X = 11.317 +- 2.779 uTm 14:50:06 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:50:11 Integrated Voltage Measurement... 14:50:20 Voltage Offset Correction: v_off_ini = 2237.151 uV, v_off_fin = 2205.159 uV 14:50:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -194.657 uVs 14:50:20 Integrated Voltage Measurement... 14:50:29 Voltage Offset Correction: v_off_ini = 2209.088 uV, v_off_fin = 2224.310 uV 14:50:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 189.673 uVs 14:50:29 Integrated Voltage Measurement... 14:50:38 Voltage Offset Correction: v_off_ini = 2209.445 uV, v_off_fin = 2236.187 uV 14:50:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -192.315 uVs 14:50:38 Integrated Voltage Measurement... 14:50:47 Voltage Offset Correction: v_off_ini = 2228.623 uV, v_off_fin = 2238.871 uV 14:50:47 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 206.746 uVs 14:50:47 Integrated Voltage Measurement... 14:50:56 Voltage Offset Correction: v_off_ini = 2219.139 uV, v_off_fin = 2221.815 uV 14:50:56 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -184.608 uVs 14:50:56 Integrated Voltage Measurement... 14:51:05 Voltage Offset Correction: v_off_ini = 2220.024 uV, v_off_fin = 2232.180 uV 14:51:05 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 204.423 uVs 14:51:09 I1Y Average and RMS of Measurements VT = -195.404 +- 3.072 uVs I1Y = -39.081 +- 0.614 uTm 14:51:14 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:51:16 Integrated Voltage Measurement... 14:51:25 Voltage Offset Correction: v_off_ini = 2207.353 uV, v_off_fin = 2219.232 uV 14:51:25 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.599 uVs 14:51:25 Integrated Voltage Measurement... 14:51:34 Voltage Offset Correction: v_off_ini = 2227.731 uV, v_off_fin = 2214.161 uV 14:51:34 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.765 uVs 14:51:35 Integrated Voltage Measurement... 14:51:43 Voltage Offset Correction: v_off_ini = 2206.874 uV, v_off_fin = 2208.668 uV 14:51:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -37.090 uVs 14:51:44 Integrated Voltage Measurement... 14:51:53 Voltage Offset Correction: v_off_ini = 2206.920 uV, v_off_fin = 2200.042 uV 14:51:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 36.869 uVs 14:51:53 Integrated Voltage Measurement... 14:52:02 Voltage Offset Correction: v_off_ini = 2201.483 uV, v_off_fin = 2195.151 uV 14:52:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -48.534 uVs 14:52:02 Integrated Voltage Measurement... 14:52:11 Voltage Offset Correction: v_off_ini = 2214.608 uV, v_off_fin = 2227.691 uV 14:52:11 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 13.970 uVs 14:52:13 I2X Average and RMS of Measurements VT = -35.305 +- 2.880 uVs I2X = 3.248 +- 0.265 uTm^2 14:52:18 Wire Position: X0 = 2.0000 mm, Y0 = 0.0000 mm 14:52:21 Integrated Voltage Measurement... 14:52:30 Voltage Offset Correction: v_off_ini = 2213.085 uV, v_off_fin = 2221.814 uV 14:52:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -240.732 uVs 14:52:30 Integrated Voltage Measurement... 14:52:39 Voltage Offset Correction: v_off_ini = 2232.325 uV, v_off_fin = 2217.845 uV 14:52:39 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 183.233 uVs 14:52:39 Integrated Voltage Measurement... 14:52:48 Voltage Offset Correction: v_off_ini = 2218.599 uV, v_off_fin = 2214.268 uV 14:52:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -192.806 uVs 14:52:48 Integrated Voltage Measurement... 14:52:57 Voltage Offset Correction: v_off_ini = 2232.722 uV, v_off_fin = 2237.704 uV 14:52:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 186.036 uVs 14:52:57 Integrated Voltage Measurement... 14:53:06 Voltage Offset Correction: v_off_ini = 2208.525 uV, v_off_fin = 2224.846 uV 14:53:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -188.863 uVs 14:53:06 Integrated Voltage Measurement... 14:53:15 Voltage Offset Correction: v_off_ini = 2242.041 uV, v_off_fin = 2227.752 uV 14:53:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 195.941 uVs 14:53:17 I2Y Average and RMS of Measurements VT = -197.935 +- 10.007 uVs I2Y = -18.210 +- 0.921 uTm^2 14:53:25 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:53:29 Integrated Voltage Measurement... 14:53:38 Voltage Offset Correction: v_off_ini = 2222.630 uV, v_off_fin = 2208.989 uV 14:53:38 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.4999 mm dXY = -0.5000 mm VT = -37.005 uVs 14:53:38 Integrated Voltage Measurement... 14:53:47 Voltage Offset Correction: v_off_ini = 2203.761 uV, v_off_fin = 2197.248 uV 14:53:47 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 68.994 uVs 14:53:47 Integrated Voltage Measurement... 14:53:56 Voltage Offset Correction: v_off_ini = 2199.686 uV, v_off_fin = 2220.647 uV 14:53:56 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -53.932 uVs 14:53:56 Integrated Voltage Measurement... 14:54:05 Voltage Offset Correction: v_off_ini = 2219.199 uV, v_off_fin = 2200.153 uV 14:54:05 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.558 uVs 14:54:05 Integrated Voltage Measurement... 14:54:14 Voltage Offset Correction: v_off_ini = 2212.754 uV, v_off_fin = 2203.435 uV 14:54:14 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -21.698 uVs 14:54:14 Integrated Voltage Measurement... 14:54:23 Voltage Offset Correction: v_off_ini = 2188.099 uV, v_off_fin = 2194.585 uV 14:54:23 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 45.718 uVs 14:54:27 I1X Average and RMS of Measurements VT = -50.151 +- 12.427 uVs I1X = 10.030 +- 2.485 uTm 14:54:30 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:54:34 Integrated Voltage Measurement... 14:54:43 Voltage Offset Correction: v_off_ini = 2204.236 uV, v_off_fin = 2195.207 uV 14:54:43 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -193.891 uVs 14:54:43 Integrated Voltage Measurement... 14:54:52 Voltage Offset Correction: v_off_ini = 2199.152 uV, v_off_fin = 2208.952 uV 14:54:52 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 203.697 uVs 14:54:52 Integrated Voltage Measurement... 14:55:01 Voltage Offset Correction: v_off_ini = 2179.191 uV, v_off_fin = 2160.088 uV 14:55:01 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.202 uVs 14:55:01 Integrated Voltage Measurement... 14:55:10 Voltage Offset Correction: v_off_ini = 2182.617 uV, v_off_fin = 2188.821 uV 14:55:10 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 182.375 uVs 14:55:10 Integrated Voltage Measurement... 14:55:19 Voltage Offset Correction: v_off_ini = 2172.833 uV, v_off_fin = 2156.997 uV 14:55:19 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -186.224 uVs 14:55:19 Integrated Voltage Measurement... 14:55:28 Voltage Offset Correction: v_off_ini = 2179.131 uV, v_off_fin = 2180.359 uV 14:55:28 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.192 uVs 14:55:32 I1Y Average and RMS of Measurements VT = -190.597 +- 5.962 uVs I1Y = -38.119 +- 1.192 uTm 14:55:35 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:55:37 Integrated Voltage Measurement... 14:55:46 Voltage Offset Correction: v_off_ini = 2162.111 uV, v_off_fin = 2178.548 uV 14:55:46 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -39.428 uVs 14:55:46 Integrated Voltage Measurement... 14:55:55 Voltage Offset Correction: v_off_ini = 2171.460 uV, v_off_fin = 2206.557 uV 14:55:55 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.723 uVs 14:55:55 Integrated Voltage Measurement... 14:56:04 Voltage Offset Correction: v_off_ini = 2177.559 uV, v_off_fin = 2189.027 uV 14:56:04 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -55.022 uVs 14:56:04 Integrated Voltage Measurement... 14:56:13 Voltage Offset Correction: v_off_ini = 2183.134 uV, v_off_fin = 2196.308 uV 14:56:13 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 43.258 uVs 14:56:13 Integrated Voltage Measurement... 14:56:22 Voltage Offset Correction: v_off_ini = 2186.875 uV, v_off_fin = 2176.710 uV 14:56:22 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = -42.286 uVs 14:56:22 Integrated Voltage Measurement... 14:56:31 Voltage Offset Correction: v_off_ini = 2190.665 uV, v_off_fin = 2226.513 uV 14:56:31 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 30.869 uVs 14:56:34 I2X Average and RMS of Measurements VT = -42.598 +- 5.142 uVs I2X = 3.919 +- 0.473 uTm^2 14:56:36 Wire Position: X0 = 0.0000 mm, Y0 = -1.0000 mm 14:56:39 Integrated Voltage Measurement... 14:56:48 Voltage Offset Correction: v_off_ini = 2200.364 uV, v_off_fin = 2195.488 uV 14:56:48 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.154 uVs 14:56:48 Integrated Voltage Measurement... 14:56:57 Voltage Offset Correction: v_off_ini = 2206.665 uV, v_off_fin = 2203.610 uV 14:56:57 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 199.926 uVs 14:56:57 Integrated Voltage Measurement... 14:57:06 Voltage Offset Correction: v_off_ini = 2220.817 uV, v_off_fin = 2213.400 uV 14:57:06 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -202.601 uVs 14:57:06 Integrated Voltage Measurement... 14:57:15 Voltage Offset Correction: v_off_ini = 2200.034 uV, v_off_fin = 2214.404 uV 14:57:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 181.549 uVs 14:57:15 Integrated Voltage Measurement... 14:57:24 Voltage Offset Correction: v_off_ini = 2192.308 uV, v_off_fin = 2186.982 uV 14:57:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -186.749 uVs 14:57:24 Integrated Voltage Measurement... 14:57:33 Voltage Offset Correction: v_off_ini = 2188.330 uV, v_off_fin = 2177.627 uV 14:57:33 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 149.332 uVs 14:57:36 I2Y Average and RMS of Measurements VT = -183.052 +- 10.687 uVs I2Y = -16.841 +- 0.983 uTm^2 14:57:40 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:57:44 Integrated Voltage Measurement... 14:57:53 Voltage Offset Correction: v_off_ini = 2184.362 uV, v_off_fin = 2178.986 uV 14:57:53 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -49.385 uVs 14:57:53 Integrated Voltage Measurement... 14:58:02 Voltage Offset Correction: v_off_ini = 2203.116 uV, v_off_fin = 2194.828 uV 14:58:02 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 53.741 uVs 14:58:02 Integrated Voltage Measurement... 14:58:11 Voltage Offset Correction: v_off_ini = 2191.711 uV, v_off_fin = 2173.381 uV 14:58:11 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -43.174 uVs 14:58:11 Integrated Voltage Measurement... 14:58:20 Voltage Offset Correction: v_off_ini = 2176.135 uV, v_off_fin = 2166.310 uV 14:58:20 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 58.671 uVs 14:58:20 Integrated Voltage Measurement... 14:58:29 Voltage Offset Correction: v_off_ini = 2173.088 uV, v_off_fin = 2160.720 uV 14:58:29 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -55.961 uVs 14:58:29 Integrated Voltage Measurement... 14:58:38 Voltage Offset Correction: v_off_ini = 2180.685 uV, v_off_fin = 2181.305 uV 14:58:38 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.737 uVs 14:58:42 I1X Average and RMS of Measurements VT = -49.445 +- 2.556 uVs I1X = 9.889 +- 0.512 uTm 14:58:45 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:58:49 Integrated Voltage Measurement... 14:58:58 Voltage Offset Correction: v_off_ini = 2182.759 uV, v_off_fin = 2182.600 uV 14:58:58 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -176.886 uVs 14:58:58 Integrated Voltage Measurement... 14:59:07 Voltage Offset Correction: v_off_ini = 2194.997 uV, v_off_fin = 2202.704 uV 14:59:07 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 185.607 uVs 14:59:07 Integrated Voltage Measurement... 14:59:16 Voltage Offset Correction: v_off_ini = 2178.577 uV, v_off_fin = 2165.154 uV 14:59:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.416 uVs 14:59:16 Integrated Voltage Measurement... 14:59:25 Voltage Offset Correction: v_off_ini = 2192.355 uV, v_off_fin = 2200.397 uV 14:59:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 211.626 uVs 14:59:25 Integrated Voltage Measurement... 14:59:34 Voltage Offset Correction: v_off_ini = 2192.015 uV, v_off_fin = 2202.627 uV 14:59:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -189.856 uVs 14:59:34 Integrated Voltage Measurement... 14:59:43 Voltage Offset Correction: v_off_ini = 2201.725 uV, v_off_fin = 2199.679 uV 14:59:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 190.955 uVs 14:59:47 I1Y Average and RMS of Measurements VT = -187.724 +- 4.603 uVs I1Y = -37.545 +- 0.921 uTm 14:59:49 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 14:59:52 Integrated Voltage Measurement... 15:00:01 Voltage Offset Correction: v_off_ini = 2206.768 uV, v_off_fin = 2173.841 uV 15:00:01 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -56.662 uVs 15:00:01 Integrated Voltage Measurement... 15:00:10 Voltage Offset Correction: v_off_ini = 2202.632 uV, v_off_fin = 2193.178 uV 15:00:10 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.998 uVs 15:00:10 Integrated Voltage Measurement... 15:00:19 Voltage Offset Correction: v_off_ini = 2167.367 uV, v_off_fin = 2171.127 uV 15:00:19 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -34.396 uVs 15:00:19 Integrated Voltage Measurement... 15:00:28 Voltage Offset Correction: v_off_ini = 2189.414 uV, v_off_fin = 2187.624 uV 15:00:28 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 39.580 uVs 15:00:28 Integrated Voltage Measurement... 15:00:37 Voltage Offset Correction: v_off_ini = 2177.347 uV, v_off_fin = 2167.466 uV 15:00:37 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -31.389 uVs 15:00:37 Integrated Voltage Measurement... 15:00:46 Voltage Offset Correction: v_off_ini = 2208.099 uV, v_off_fin = 2194.553 uV 15:00:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 33.301 uVs 15:00:48 I2X Average and RMS of Measurements VT = -36.721 +- 3.469 uVs I2X = 3.378 +- 0.319 uTm^2 15:00:51 Wire Position: X0 = 0.0000 mm, Y0 = -0.5000 mm 15:00:54 Integrated Voltage Measurement... 15:01:03 Voltage Offset Correction: v_off_ini = 2183.345 uV, v_off_fin = 2186.127 uV 15:01:03 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -191.402 uVs 15:01:03 Integrated Voltage Measurement... 15:01:12 Voltage Offset Correction: v_off_ini = 2184.045 uV, v_off_fin = 2192.873 uV 15:01:12 Integrated Voltage Measurement dXYus = -0.9999 mm, dXYds = 0.0000 mm dXY = -0.9999 mm VT = 187.741 uVs 15:01:12 Integrated Voltage Measurement... 15:01:21 Voltage Offset Correction: v_off_ini = 2199.318 uV, v_off_fin = 2174.185 uV 15:01:21 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -200.424 uVs 15:01:21 Integrated Voltage Measurement... 15:01:30 Voltage Offset Correction: v_off_ini = 2192.673 uV, v_off_fin = 2174.199 uV 15:01:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 188.500 uVs 15:01:30 Integrated Voltage Measurement... 15:01:39 Voltage Offset Correction: v_off_ini = 2186.213 uV, v_off_fin = 2174.045 uV 15:01:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -172.178 uVs 15:01:39 Integrated Voltage Measurement... 15:01:48 Voltage Offset Correction: v_off_ini = 2195.433 uV, v_off_fin = 2195.874 uV 15:01:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 184.563 uVs 15:01:50 I2Y Average and RMS of Measurements VT = -187.468 +- 6.736 uVs I2Y = -17.247 +- 0.620 uTm^2 15:01:54 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:01:58 Integrated Voltage Measurement... 15:02:07 Voltage Offset Correction: v_off_ini = 2177.922 uV, v_off_fin = 2160.444 uV 15:02:07 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -51.495 uVs 15:02:07 Integrated Voltage Measurement... 15:02:16 Voltage Offset Correction: v_off_ini = 2181.451 uV, v_off_fin = 2173.416 uV 15:02:16 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 43.148 uVs 15:02:16 Integrated Voltage Measurement... 15:02:25 Voltage Offset Correction: v_off_ini = 2176.679 uV, v_off_fin = 2180.986 uV 15:02:25 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -58.083 uVs 15:02:25 Integrated Voltage Measurement... 15:02:34 Voltage Offset Correction: v_off_ini = 2190.361 uV, v_off_fin = 2180.807 uV 15:02:34 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 26.329 uVs 15:02:34 Integrated Voltage Measurement... 15:02:43 Voltage Offset Correction: v_off_ini = 2184.987 uV, v_off_fin = 2179.470 uV 15:02:43 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -45.114 uVs 15:02:43 Integrated Voltage Measurement... 15:02:52 Voltage Offset Correction: v_off_ini = 2162.069 uV, v_off_fin = 2175.035 uV 15:02:52 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 73.375 uVs 15:02:57 I1X Average and RMS of Measurements VT = -49.591 +- 7.138 uVs I1X = 9.919 +- 1.428 uTm 15:02:59 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:03:03 Integrated Voltage Measurement... 15:03:12 Voltage Offset Correction: v_off_ini = 2192.479 uV, v_off_fin = 2179.865 uV 15:03:12 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -181.944 uVs 15:03:12 Integrated Voltage Measurement... 15:03:21 Voltage Offset Correction: v_off_ini = 2192.150 uV, v_off_fin = 2181.136 uV 15:03:21 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 197.427 uVs 15:03:21 Integrated Voltage Measurement... 15:03:30 Voltage Offset Correction: v_off_ini = 2177.469 uV, v_off_fin = 2182.602 uV 15:03:30 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -182.688 uVs 15:03:30 Integrated Voltage Measurement... 15:03:39 Voltage Offset Correction: v_off_ini = 2179.964 uV, v_off_fin = 2182.917 uV 15:03:39 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 176.679 uVs 15:03:39 Integrated Voltage Measurement... 15:03:48 Voltage Offset Correction: v_off_ini = 2199.101 uV, v_off_fin = 2179.815 uV 15:03:48 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -191.264 uVs 15:03:48 Integrated Voltage Measurement... 15:03:57 Voltage Offset Correction: v_off_ini = 2187.251 uV, v_off_fin = 2203.706 uV 15:03:57 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 187.676 uVs 15:04:01 I1Y Average and RMS of Measurements VT = -186.280 +- 4.665 uVs I1Y = -37.256 +- 0.933 uTm 15:04:04 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:04:06 Integrated Voltage Measurement... 15:04:15 Voltage Offset Correction: v_off_ini = 2179.808 uV, v_off_fin = 2178.047 uV 15:04:15 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.449 uVs 15:04:15 Integrated Voltage Measurement... 15:04:24 Voltage Offset Correction: v_off_ini = 2189.222 uV, v_off_fin = 2198.493 uV 15:04:24 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 50.339 uVs 15:04:25 Integrated Voltage Measurement... 15:04:33 Voltage Offset Correction: v_off_ini = 2176.529 uV, v_off_fin = 2176.429 uV 15:04:34 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -36.850 uVs 15:04:34 Integrated Voltage Measurement... 15:04:43 Voltage Offset Correction: v_off_ini = 2174.548 uV, v_off_fin = 2173.337 uV 15:04:43 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 56.508 uVs 15:04:43 Integrated Voltage Measurement... 15:04:52 Voltage Offset Correction: v_off_ini = 2182.567 uV, v_off_fin = 2161.848 uV 15:04:52 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -67.606 uVs 15:04:52 Integrated Voltage Measurement... 15:05:01 Voltage Offset Correction: v_off_ini = 2183.167 uV, v_off_fin = 2202.694 uV 15:05:01 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 42.223 uVs 15:05:03 I2X Average and RMS of Measurements VT = -48.329 +- 4.846 uVs I2X = 4.446 +- 0.446 uTm^2 15:05:05 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm 15:05:08 Integrated Voltage Measurement... 15:05:17 Voltage Offset Correction: v_off_ini = 2180.332 uV, v_off_fin = 2186.543 uV 15:05:17 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.782 uVs 15:05:17 Integrated Voltage Measurement... 15:05:26 Voltage Offset Correction: v_off_ini = 2187.758 uV, v_off_fin = 2176.017 uV 15:05:26 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.317 uVs 15:05:26 Integrated Voltage Measurement... 15:05:35 Voltage Offset Correction: v_off_ini = 2168.286 uV, v_off_fin = 2171.658 uV 15:05:35 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -190.567 uVs 15:05:35 Integrated Voltage Measurement... 15:05:44 Voltage Offset Correction: v_off_ini = 2178.348 uV, v_off_fin = 2192.277 uV 15:05:44 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 208.107 uVs 15:05:44 Integrated Voltage Measurement... 15:05:53 Voltage Offset Correction: v_off_ini = 2193.782 uV, v_off_fin = 2183.066 uV 15:05:53 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -207.321 uVs 15:05:53 Integrated Voltage Measurement... 15:06:02 Voltage Offset Correction: v_off_ini = 2182.600 uV, v_off_fin = 2190.226 uV 15:06:02 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 175.719 uVs 15:06:05 I2Y Average and RMS of Measurements VT = -196.135 +- 3.344 uVs I2Y = -18.044 +- 0.308 uTm^2 15:06:09 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:06:13 Integrated Voltage Measurement... 15:06:22 Voltage Offset Correction: v_off_ini = 2184.056 uV, v_off_fin = 2172.089 uV 15:06:22 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4999 mm VT = -48.366 uVs 15:06:22 Integrated Voltage Measurement... 15:06:31 Voltage Offset Correction: v_off_ini = 2191.205 uV, v_off_fin = 2181.686 uV 15:06:31 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 29.445 uVs 15:06:31 Integrated Voltage Measurement... 15:06:40 Voltage Offset Correction: v_off_ini = 2205.245 uV, v_off_fin = 2181.632 uV 15:06:40 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -60.901 uVs 15:06:40 Integrated Voltage Measurement... 15:06:49 Voltage Offset Correction: v_off_ini = 2178.397 uV, v_off_fin = 2169.060 uV 15:06:49 Integrated Voltage Measurement dXYus = 0.4999 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 37.345 uVs 15:06:49 Integrated Voltage Measurement... 15:06:58 Voltage Offset Correction: v_off_ini = 2169.826 uV, v_off_fin = 2158.235 uV 15:06:58 Integrated Voltage Measurement dXYus = -0.4999 mm, dXYds = -0.4998 mm dXY = -0.4998 mm VT = -47.669 uVs 15:06:58 Integrated Voltage Measurement... 15:07:07 Voltage Offset Correction: v_off_ini = 2168.333 uV, v_off_fin = 2168.313 uV 15:07:07 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 24.820 uVs 15:07:11 I1X Average and RMS of Measurements VT = -41.424 +- 5.551 uVs I1X = 8.286 +- 1.110 uTm 15:07:14 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:07:18 Integrated Voltage Measurement... 15:07:27 Voltage Offset Correction: v_off_ini = 2172.407 uV, v_off_fin = 2172.880 uV 15:07:27 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -198.752 uVs 15:07:27 Integrated Voltage Measurement... 15:07:36 Voltage Offset Correction: v_off_ini = 2171.522 uV, v_off_fin = 2189.273 uV 15:07:36 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 184.861 uVs 15:07:36 Integrated Voltage Measurement... 15:07:45 Voltage Offset Correction: v_off_ini = 2172.744 uV, v_off_fin = 2162.180 uV 15:07:45 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -175.506 uVs 15:07:45 Integrated Voltage Measurement... 15:07:54 Voltage Offset Correction: v_off_ini = 2165.708 uV, v_off_fin = 2179.833 uV 15:07:54 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 180.804 uVs 15:07:54 Integrated Voltage Measurement... 15:08:03 Voltage Offset Correction: v_off_ini = 2160.750 uV, v_off_fin = 2157.200 uV 15:08:03 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -187.410 uVs 15:08:03 Integrated Voltage Measurement... 15:08:12 Voltage Offset Correction: v_off_ini = 2159.141 uV, v_off_fin = 2160.529 uV 15:08:12 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = 202.705 uVs 15:08:16 I1Y Average and RMS of Measurements VT = -188.340 +- 7.323 uVs I1Y = -37.668 +- 1.465 uTm 15:08:18 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:08:21 Integrated Voltage Measurement... 15:08:30 Voltage Offset Correction: v_off_ini = 2162.457 uV, v_off_fin = 2160.661 uV 15:08:30 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -18.636 uVs 15:08:30 Integrated Voltage Measurement... 15:08:39 Voltage Offset Correction: v_off_ini = 2152.294 uV, v_off_fin = 2189.407 uV 15:08:39 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 41.352 uVs 15:08:39 Integrated Voltage Measurement... 15:08:48 Voltage Offset Correction: v_off_ini = 2179.541 uV, v_off_fin = 2138.818 uV 15:08:48 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -42.984 uVs 15:08:48 Integrated Voltage Measurement... 15:08:57 Voltage Offset Correction: v_off_ini = 2135.638 uV, v_off_fin = 2156.762 uV 15:08:57 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 61.264 uVs 15:08:57 Integrated Voltage Measurement... 15:09:06 Voltage Offset Correction: v_off_ini = 2152.886 uV, v_off_fin = 2159.575 uV 15:09:06 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -17.628 uVs 15:09:06 Integrated Voltage Measurement... 15:09:15 Voltage Offset Correction: v_off_ini = 2160.002 uV, v_off_fin = 2167.443 uV 15:09:15 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 47.936 uVs 15:09:18 I2X Average and RMS of Measurements VT = -38.300 +- 9.841 uVs I2X = 3.524 +- 0.905 uTm^2 15:09:20 Wire Position: X0 = 0.0000 mm, Y0 = 0.5000 mm 15:09:23 Integrated Voltage Measurement... 15:09:32 Voltage Offset Correction: v_off_ini = 2176.972 uV, v_off_fin = 2157.908 uV 15:09:32 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -187.539 uVs 15:09:32 Integrated Voltage Measurement... 15:09:41 Voltage Offset Correction: v_off_ini = 2145.199 uV, v_off_fin = 2136.307 uV 15:09:41 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 167.424 uVs 15:09:41 Integrated Voltage Measurement... 15:09:50 Voltage Offset Correction: v_off_ini = 2155.093 uV, v_off_fin = 2142.867 uV 15:09:50 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -178.082 uVs 15:09:50 Integrated Voltage Measurement... 15:09:59 Voltage Offset Correction: v_off_ini = 2139.975 uV, v_off_fin = 2140.896 uV 15:09:59 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 197.178 uVs 15:09:59 Integrated Voltage Measurement... 15:10:08 Voltage Offset Correction: v_off_ini = 2169.224 uV, v_off_fin = 2149.755 uV 15:10:08 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -162.987 uVs 15:10:08 Integrated Voltage Measurement... 15:10:17 Voltage Offset Correction: v_off_ini = 2164.379 uV, v_off_fin = 2155.753 uV 15:10:17 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 185.310 uVs 15:10:19 I2Y Average and RMS of Measurements VT = -179.753 +- 5.733 uVs I2Y = -16.537 +- 0.527 uTm^2 15:10:23 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:10:28 Integrated Voltage Measurement... 15:10:37 Voltage Offset Correction: v_off_ini = 2165.415 uV, v_off_fin = 2150.245 uV 15:10:37 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -66.583 uVs 15:10:37 Integrated Voltage Measurement... 15:10:46 Voltage Offset Correction: v_off_ini = 2160.766 uV, v_off_fin = 2156.758 uV 15:10:46 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 35.425 uVs 15:10:46 Integrated Voltage Measurement... 15:10:55 Voltage Offset Correction: v_off_ini = 2164.212 uV, v_off_fin = 2152.761 uV 15:10:55 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -26.094 uVs 15:10:55 Integrated Voltage Measurement... 15:11:04 Voltage Offset Correction: v_off_ini = 2157.567 uV, v_off_fin = 2200.178 uV 15:11:04 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = 22.517 uVs 15:11:04 Integrated Voltage Measurement... 15:11:13 Voltage Offset Correction: v_off_ini = 2173.514 uV, v_off_fin = 2178.892 uV 15:11:13 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5000 mm dXY = -0.5000 mm VT = -47.994 uVs 15:11:13 Integrated Voltage Measurement... 15:11:22 Voltage Offset Correction: v_off_ini = 2196.773 uV, v_off_fin = 2188.524 uV 15:11:22 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.4999 mm dXY = 0.5000 mm VT = 19.519 uVs 15:11:26 I1X Average and RMS of Measurements VT = -36.355 +- 11.053 uVs I1X = 7.271 +- 2.211 uTm 15:11:28 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:11:33 Integrated Voltage Measurement... 15:11:41 Voltage Offset Correction: v_off_ini = 2172.478 uV, v_off_fin = 2161.428 uV 15:11:42 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -182.973 uVs 15:11:42 Integrated Voltage Measurement... 15:11:50 Voltage Offset Correction: v_off_ini = 2181.868 uV, v_off_fin = 2184.729 uV 15:11:50 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 199.016 uVs 15:11:51 Integrated Voltage Measurement... 15:11:59 Voltage Offset Correction: v_off_ini = 2158.861 uV, v_off_fin = 2139.422 uV 15:11:59 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5000 mm dXY = 0.5000 mm VT = -171.315 uVs 15:12:00 Integrated Voltage Measurement... 15:12:08 Voltage Offset Correction: v_off_ini = 2177.882 uV, v_off_fin = 2183.633 uV 15:12:08 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 185.670 uVs 15:12:09 Integrated Voltage Measurement... 15:12:17 Voltage Offset Correction: v_off_ini = 2163.873 uV, v_off_fin = 2160.913 uV 15:12:17 Integrated Voltage Measurement dXYus = 0.5000 mm, dXYds = 0.5001 mm dXY = 0.5000 mm VT = -170.296 uVs 15:12:18 Integrated Voltage Measurement... 15:12:26 Voltage Offset Correction: v_off_ini = 2172.366 uV, v_off_fin = 2164.469 uV 15:12:26 Integrated Voltage Measurement dXYus = -0.5000 mm, dXYds = -0.5001 mm dXY = -0.5000 mm VT = 177.908 uVs 15:12:31 I1Y Average and RMS of Measurements VT = -181.196 +- 7.156 uVs I1Y = -36.236 +- 1.431 uTm 15:12:33 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:12:36 Integrated Voltage Measurement... 15:12:45 Voltage Offset Correction: v_off_ini = 2154.149 uV, v_off_fin = 2165.345 uV 15:12:45 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -24.220 uVs 15:12:45 Integrated Voltage Measurement... 15:12:54 Voltage Offset Correction: v_off_ini = 2178.244 uV, v_off_fin = 2161.627 uV 15:12:54 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 44.386 uVs 15:12:54 Integrated Voltage Measurement... 15:13:03 Voltage Offset Correction: v_off_ini = 2167.732 uV, v_off_fin = 2142.912 uV 15:13:03 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -47.174 uVs 15:13:03 Integrated Voltage Measurement... 15:13:12 Voltage Offset Correction: v_off_ini = 2154.966 uV, v_off_fin = 2172.587 uV 15:13:12 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 24.081 uVs 15:13:12 Integrated Voltage Measurement... 15:13:21 Voltage Offset Correction: v_off_ini = 2183.807 uV, v_off_fin = 2170.244 uV 15:13:21 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = -33.300 uVs 15:13:21 Integrated Voltage Measurement... 15:13:30 Voltage Offset Correction: v_off_ini = 2187.593 uV, v_off_fin = 2172.022 uV 15:13:30 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = 20.529 uVs 15:13:32 I2X Average and RMS of Measurements VT = -32.282 +- 3.833 uVs I2X = 2.970 +- 0.353 uTm^2 15:13:35 Wire Position: X0 = 0.0000 mm, Y0 = 1.0000 mm 15:13:37 Integrated Voltage Measurement... 15:13:46 Voltage Offset Correction: v_off_ini = 2217.124 uV, v_off_fin = 2201.114 uV 15:13:46 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -199.526 uVs 15:13:46 Integrated Voltage Measurement... 15:13:55 Voltage Offset Correction: v_off_ini = 2175.452 uV, v_off_fin = 2164.718 uV 15:13:55 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 198.779 uVs 15:13:56 Integrated Voltage Measurement... 15:14:04 Voltage Offset Correction: v_off_ini = 2189.821 uV, v_off_fin = 2191.725 uV 15:14:05 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -203.987 uVs 15:14:05 Integrated Voltage Measurement... 15:14:14 Voltage Offset Correction: v_off_ini = 2197.080 uV, v_off_fin = 2207.808 uV 15:14:14 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 192.829 uVs 15:14:14 Integrated Voltage Measurement... 15:14:23 Voltage Offset Correction: v_off_ini = 2204.438 uV, v_off_fin = 2193.501 uV 15:14:23 Integrated Voltage Measurement dXYus = 1.0000 mm, dXYds = 0.0000 mm dXY = 1.0000 mm VT = -173.623 uVs 15:14:23 Integrated Voltage Measurement... 15:14:32 Voltage Offset Correction: v_off_ini = 2195.736 uV, v_off_fin = 2192.556 uV 15:14:32 Integrated Voltage Measurement dXYus = -1.0000 mm, dXYds = 0.0000 mm dXY = -1.0000 mm VT = 191.257 uVs 15:14:34 I2Y Average and RMS of Measurements VT = -193.333 +- 7.709 uVs I2Y = -17.787 +- 0.709 uTm^2 15:14:39 Wire Position: X0 = 0.0000 mm, Y0 = 0.0000 mm