SLAC Magnetic Measurements
Date: 01-23-2025
Time: 10:04:04

Project: LBL
Magnet Type: Quad
Magnet Name: TQFC_Q11_BTA_QF8
Serial Number: AL-1423-8026-0001
Run Number: 6
Measurement Device: 1DQB26
Operator: sda
Comment: Check Sens factor after changing BLHar Ref Radius.  Moved coil 25 microns to left


              Test Parameter Measurements

P0 = MAIN
P1 = Main (V)
P2 = Core_Top
P3 = Top_Coil
P4 = H20 In
P5 = H20 Out
P6 = Ambient
P7 = Supply Pres(psi)
P8 = Return Pres(psi)
P9 = Flow Rate(gpm)

   Time     P0      P1      P2      P3      P4      P5      P6      P7      P8      P9   
--------- ------- ------- ------- ------- ------- ------- ------- ------- ------- -------
    0.00   184.963  14.383  19.135  22.131  27.869  29.534  14.922 124.037  12.126   1.544
    3.02   184.964  14.391  19.035  22.460  27.906  33.688  14.954 125.293  12.250   1.524
   11.23   184.965  14.395  19.186  23.347  27.936  34.155  15.202 121.739  12.439   1.534