SLAC Magnetic Measurements Date: 11-29-2004 Time: 11:07:15 Project: klystron Magnet Type: solenoid Magnet Name: YW_Gun_Coil Serial Number: Run Number: 2 Measurement Device: Coil X Operator: sda Comment: Transverse, Coil A = 12.2575 , Temp = 28.4 C, Coil B is recorded as Imag, temp = 30.5 C. Test Currents (A): 32.8 11:07:27 Btcoil, device being used, type = SR850 11:07:37 Stage Zeroed 11:07:37 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 11:07:38 Initial Zero Current Measurement, Imag_zero = 0.0000 A 11:07:38 Magnet current ramping to 32.8300 A... 11:09:33 Stage moved to, position = -0.260000 11:09:35 Stage Position Measurement, pos = -0.260270 m 11:09:37 Magnet Current, Imag = 21.8784 A Vtrans = 1.750271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:10:01 Coil Voltage Measurement meas_freq = 30.003500 Hz, meas_v_mag = 0.000004 V, meas_v_ph = 111.708000 deg freq = 30.003500 Hz, v_amp = 0.000006 V, v_ph = 21.708000 deg 11:10:01 Transverse Field Calculation freq = 30.003500 Hz, v_amp = 0.000006 V, v_ph = 21.708000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000023 T, THsp = -21.708000 deg 11:10:11 Stage moved to, position = -0.240000 11:10:13 Stage Position Measurement, pos = -0.240990 m 11:10:14 Magnet Current, Imag = 21.8780 A Vtrans = 1.750238 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:10:39 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000006 V, meas_v_ph = 118.128000 deg freq = 29.999700 Hz, v_amp = 0.000008 V, v_ph = 28.128000 deg 11:10:39 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000008 V, v_ph = 28.128000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000031 T, THsp = -28.128000 deg 11:10:49 Stage moved to, position = -0.220000 11:10:51 Stage Position Measurement, pos = -0.221005 m 11:10:52 Magnet Current, Imag = 21.8784 A Vtrans = 1.750271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:11:16 Coil Voltage Measurement meas_freq = 30.001600 Hz, meas_v_mag = 0.000003 V, meas_v_ph = 105.816000 deg freq = 30.001600 Hz, v_amp = 0.000004 V, v_ph = 15.816000 deg 11:11:16 Transverse Field Calculation freq = 30.001600 Hz, v_amp = 0.000004 V, v_ph = 15.816000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = -15.816000 deg 11:11:26 Stage moved to, position = -0.200000 11:11:28 Stage Position Measurement, pos = -0.200940 m 11:11:29 Magnet Current, Imag = 21.8785 A Vtrans = 1.750279 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:11:53 Coil Voltage Measurement meas_freq = 29.997800 Hz, meas_v_mag = 0.000004 V, meas_v_ph = 121.224000 deg freq = 29.997800 Hz, v_amp = 0.000005 V, v_ph = 31.224000 deg 11:11:53 Transverse Field Calculation freq = 29.997800 Hz, v_amp = 0.000005 V, v_ph = 31.224000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000021 T, THsp = -31.224000 deg 11:12:04 Stage moved to, position = -0.180000 11:12:05 Stage Position Measurement, pos = -0.180775 m 11:12:07 Magnet Current, Imag = 21.8781 A Vtrans = 1.750250 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:12:31 Coil Voltage Measurement meas_freq = 30.003500 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 138.300000 deg freq = 30.003500 Hz, v_amp = 0.000007 V, v_ph = 48.300000 deg 11:12:31 Transverse Field Calculation freq = 30.003500 Hz, v_amp = 0.000007 V, v_ph = 48.300000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000028 T, THsp = -48.300000 deg 11:12:42 Stage moved to, position = -0.160000 11:12:43 Stage Position Measurement, pos = -0.160795 m 11:12:44 Magnet Current, Imag = 21.8784 A Vtrans = 1.750274 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:13:09 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000005 V, meas_v_ph = 149.982000 deg freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 59.982000 deg 11:13:09 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000007 V, v_ph = 59.982000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000027 T, THsp = -59.982000 deg 11:13:19 Stage moved to, position = -0.140000 11:13:21 Stage Position Measurement, pos = -0.140775 m 11:13:22 Magnet Current, Imag = 21.8784 A Vtrans = 1.750271 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:13:47 Coil Voltage Measurement meas_freq = 30.006400 Hz, meas_v_mag = 0.000008 V, meas_v_ph = -170.046000 deg freq = 30.006400 Hz, v_amp = 0.000012 V, v_ph = 99.954000 deg 11:13:47 Transverse Field Calculation freq = 30.006400 Hz, v_amp = 0.000012 V, v_ph = 99.954000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000045 T, THsp = -99.954000 deg 11:13:57 Stage moved to, position = -0.120000 11:13:59 Stage Position Measurement, pos = -0.120720 m 11:14:00 Magnet Current, Imag = 21.8780 A Vtrans = 1.750243 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:14:24 Coil Voltage Measurement meas_freq = 30.003500 Hz, meas_v_mag = 0.000006 V, meas_v_ph = 175.272000 deg freq = 30.003500 Hz, v_amp = 0.000009 V, v_ph = 85.272000 deg 11:14:24 Transverse Field Calculation freq = 30.003500 Hz, v_amp = 0.000009 V, v_ph = 85.272000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000033 T, THsp = -85.272000 deg 11:14:34 Stage moved to, position = -0.100000 11:14:35 Stage Position Measurement, pos = -0.100720 m 11:14:37 Magnet Current, Imag = 21.8780 A Vtrans = 1.750244 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:15:01 Coil Voltage Measurement meas_freq = 30.001600 Hz, meas_v_mag = 0.000008 V, meas_v_ph = -173.472000 deg freq = 30.001600 Hz, v_amp = 0.000011 V, v_ph = 96.528000 deg 11:15:01 Transverse Field Calculation freq = 30.001600 Hz, v_amp = 0.000011 V, v_ph = 96.528000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000043 T, THsp = -96.528000 deg 11:15:12 Stage moved to, position = -0.080000 11:15:13 Stage Position Measurement, pos = -0.080720 m 11:15:15 Magnet Current, Imag = 21.8776 A Vtrans = 1.750208 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:15:49 Coil Voltage Measurement meas_freq = 29.994000 Hz, meas_v_mag = 0.000010 V, meas_v_ph = -157.830000 deg freq = 29.994000 Hz, v_amp = 0.000013 V, v_ph = 112.170000 deg 11:15:49 Transverse Field Calculation freq = 29.994000 Hz, v_amp = 0.000013 V, v_ph = 112.170000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000053 T, THsp = -112.170000 deg 11:15:59 Stage moved to, position = -0.060000 11:16:01 Stage Position Measurement, pos = -0.060735 m 11:16:02 Magnet Current, Imag = 21.8782 A Vtrans = 1.750256 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:16:26 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000013 V, meas_v_ph = -149.238000 deg freq = 29.998800 Hz, v_amp = 0.000019 V, v_ph = 120.762000 deg 11:16:26 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000019 V, v_ph = 120.762000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000073 T, THsp = -120.762000 deg 11:16:36 Stage moved to, position = -0.040000 11:16:38 Stage Position Measurement, pos = -0.040740 m 11:16:39 Magnet Current, Imag = 21.8775 A Vtrans = 1.750199 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:17:01 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000015 V, meas_v_ph = -131.988000 deg freq = 29.998800 Hz, v_amp = 0.000022 V, v_ph = 138.012000 deg 11:17:01 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000022 V, v_ph = 138.012000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000085 T, THsp = -138.012000 deg 11:17:12 Stage moved to, position = -0.020000 11:17:13 Stage Position Measurement, pos = -0.020700 m 11:17:14 Magnet Current, Imag = 21.8778 A Vtrans = 1.750224 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:17:48 Coil Voltage Measurement meas_freq = 29.995000 Hz, meas_v_mag = 0.000009 V, meas_v_ph = -169.506000 deg freq = 29.995000 Hz, v_amp = 0.000012 V, v_ph = 100.494000 deg 11:17:48 Transverse Field Calculation freq = 29.995000 Hz, v_amp = 0.000012 V, v_ph = 100.494000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000047 T, THsp = -100.494000 deg 11:17:59 Stage moved to, position = 0.000000 11:18:00 Stage Position Measurement, pos = -0.000650 m 11:18:02 Magnet Current, Imag = 21.8778 A Vtrans = 1.750223 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:18:36 Coil Voltage Measurement meas_freq = 29.996900 Hz, meas_v_mag = 0.000006 V, meas_v_ph = 45.000000 deg freq = 29.996900 Hz, v_amp = 0.000009 V, v_ph = -45.000000 deg 11:18:36 Transverse Field Calculation freq = 29.996900 Hz, v_amp = 0.000009 V, v_ph = -45.000000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000034 T, THsp = 45.000000 deg 11:18:46 Stage moved to, position = 0.020000 11:18:48 Stage Position Measurement, pos = 0.019385 m 11:18:49 Magnet Current, Imag = 21.8775 A Vtrans = 1.750198 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:19:24 Coil Voltage Measurement meas_freq = 30.002600 Hz, meas_v_mag = 0.000010 V, meas_v_ph = 18.432000 deg freq = 30.002600 Hz, v_amp = 0.000014 V, v_ph = -71.568000 deg 11:19:24 Transverse Field Calculation freq = 30.002600 Hz, v_amp = 0.000014 V, v_ph = -71.568000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000055 T, THsp = 71.568000 deg 11:19:35 Stage moved to, position = 0.040000 11:19:36 Stage Position Measurement, pos = 0.039425 m 11:19:37 Magnet Current, Imag = 21.8777 A Vtrans = 1.750220 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:20:12 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000009 V, meas_v_ph = 20.856000 deg freq = 29.999700 Hz, v_amp = 0.000012 V, v_ph = -69.144000 deg 11:20:12 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000012 V, v_ph = -69.144000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000047 T, THsp = 69.144000 deg 11:20:23 Stage moved to, position = 0.060000 11:20:24 Stage Position Measurement, pos = 0.059465 m 11:20:25 Magnet Current, Imag = 21.8774 A Vtrans = 1.750193 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:20:49 Coil Voltage Measurement meas_freq = 30.002600 Hz, meas_v_mag = 0.000006 V, meas_v_ph = -2.610000 deg freq = 30.002600 Hz, v_amp = 0.000008 V, v_ph = -92.610000 deg 11:20:49 Transverse Field Calculation freq = 30.002600 Hz, v_amp = 0.000008 V, v_ph = -92.610000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000032 T, THsp = 92.610000 deg 11:20:59 Stage moved to, position = 0.080000 11:21:01 Stage Position Measurement, pos = 0.079465 m 11:21:02 Magnet Current, Imag = 21.8775 A Vtrans = 1.750200 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:21:27 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000002 V, meas_v_ph = -8.826000 deg freq = 29.999700 Hz, v_amp = 0.000003 V, v_ph = -98.826000 deg 11:21:27 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000003 V, v_ph = -98.826000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000013 T, THsp = 98.826000 deg 11:21:37 Stage moved to, position = 0.100000 11:21:39 Stage Position Measurement, pos = 0.099485 m 11:21:40 Magnet Current, Imag = 21.8773 A Vtrans = 1.750185 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:22:06 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -32.964000 deg freq = 29.999700 Hz, v_amp = 0.000004 V, v_ph = -122.964000 deg 11:22:06 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000004 V, v_ph = -122.964000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = 122.964000 deg 11:22:17 Stage moved to, position = 0.120000 11:22:18 Stage Position Measurement, pos = 0.119475 m 11:22:19 Magnet Current, Imag = 21.8777 A Vtrans = 1.750218 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:22:43 Coil Voltage Measurement meas_freq = 29.999700 Hz, meas_v_mag = 0.000005 V, meas_v_ph = -36.558000 deg freq = 29.999700 Hz, v_amp = 0.000007 V, v_ph = -126.558000 deg 11:22:43 Transverse Field Calculation freq = 29.999700 Hz, v_amp = 0.000007 V, v_ph = -126.558000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000025 T, THsp = 126.558000 deg 11:22:53 Stage moved to, position = 0.140000 11:22:55 Stage Position Measurement, pos = 0.139490 m 11:22:56 Magnet Current, Imag = 21.8777 A Vtrans = 1.750218 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:23:20 Coil Voltage Measurement meas_freq = 30.006400 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -71.520000 deg freq = 30.006400 Hz, v_amp = 0.000005 V, v_ph = -161.520000 deg 11:23:20 Transverse Field Calculation freq = 30.006400 Hz, v_amp = 0.000005 V, v_ph = -161.520000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000018 T, THsp = 161.520000 deg 11:23:31 Stage moved to, position = 0.160000 11:23:32 Stage Position Measurement, pos = 0.159535 m 11:23:33 Magnet Current, Imag = 21.8779 A Vtrans = 1.750236 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:24:08 Coil Voltage Measurement meas_freq = 29.997800 Hz, meas_v_mag = 0.000009 V, meas_v_ph = -116.562000 deg freq = 29.997800 Hz, v_amp = 0.000012 V, v_ph = 153.438000 deg 11:24:08 Transverse Field Calculation freq = 29.997800 Hz, v_amp = 0.000012 V, v_ph = 153.438000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000048 T, THsp = -153.438000 deg 11:24:19 Stage moved to, position = 0.180000 11:24:20 Stage Position Measurement, pos = 0.179615 m 11:24:22 Magnet Current, Imag = 21.8774 A Vtrans = 1.750193 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:24:46 Coil Voltage Measurement meas_freq = 29.992100 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -124.158000 deg freq = 29.992100 Hz, v_amp = 0.000004 V, v_ph = 145.842000 deg 11:24:46 Transverse Field Calculation freq = 29.992100 Hz, v_amp = 0.000004 V, v_ph = 145.842000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000016 T, THsp = -145.842000 deg 11:24:56 Stage moved to, position = 0.200000 11:24:58 Stage Position Measurement, pos = 0.199675 m 11:24:59 Magnet Current, Imag = 21.8778 A Vtrans = 1.750224 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:25:24 Coil Voltage Measurement meas_freq = 29.995900 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -33.936000 deg freq = 29.995900 Hz, v_amp = 0.000004 V, v_ph = -123.936000 deg 11:25:24 Transverse Field Calculation freq = 29.995900 Hz, v_amp = 0.000004 V, v_ph = -123.936000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = 123.936000 deg 11:25:34 Stage moved to, position = 0.220000 11:25:36 Stage Position Measurement, pos = 0.219720 m 11:25:37 Magnet Current, Imag = 21.8770 A Vtrans = 1.750164 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:26:13 Coil Voltage Measurement meas_freq = 29.994000 Hz, meas_v_mag = 0.000001 V, meas_v_ph = 0.000000 deg freq = 29.994000 Hz, v_amp = 0.000002 V, v_ph = -90.000000 deg 11:26:13 Transverse Field Calculation freq = 29.994000 Hz, v_amp = 0.000002 V, v_ph = -90.000000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000007 T, THsp = 90.000000 deg 11:26:23 Stage moved to, position = 0.240000 11:26:25 Stage Position Measurement, pos = 0.239770 m 11:26:26 Magnet Current, Imag = 21.8774 A Vtrans = 1.750191 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:26:49 Coil Voltage Measurement meas_freq = 29.998800 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -44.196000 deg freq = 29.998800 Hz, v_amp = 0.000004 V, v_ph = -134.196000 deg 11:26:49 Transverse Field Calculation freq = 29.998800 Hz, v_amp = 0.000004 V, v_ph = -134.196000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000017 T, THsp = 134.196000 deg 11:27:00 Stage moved to, position = 0.260000 11:27:01 Stage Position Measurement, pos = 0.259775 m 11:27:03 Magnet Current, Imag = 21.8774 A Vtrans = 1.750192 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 11:27:27 Coil Voltage Measurement meas_freq = 30.000700 Hz, meas_v_mag = 0.000003 V, meas_v_ph = -21.012000 deg freq = 30.000700 Hz, v_amp = 0.000005 V, v_ph = -111.012000 deg 11:27:27 Transverse Field Calculation freq = 30.000700 Hz, v_amp = 0.000005 V, v_ph = -111.012000 deg Coil Constant = 3.908900 (T/V0p) Transverse Field, Bt = 0.000018 T, THsp = 111.012000 deg 11:28:26 Stage moved to, position = 0.000000 11:28:26 Magnet current ramping to 0.0000 A...