SLAC Magnetic Measurements Date: 12-06-2004 Time: 10:06:12 Project: klystron Magnet Type: solenoid Magnet Name: YW_Gun_Coil Serial Number: Run Number: 6 Measurement Device: B9900 Hall probe Operator: sa Comment: Axial hall measurement, A coil = 6.13 A, B coil measured Test Currents (A): 10.9 10:06:24 Stage Zeroed 10:06:24 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 10:07:20 Stage moved to, position = -0.200000 10:08:29 Hall Probe Zeroed 10:08:44 Hall Probe Type Being Used, type = B9900 10:09:31 Stage moved to, position = 0.000000 10:09:32 Initial Zero Current Measurement, Imag_zero = 0.0000 A 10:09:36 Hall Probe Range Set, range = 4 10:09:36 Magnet current ramping to 10.9400 A... 10:11:35 Stage moved to, position = -0.260000 10:11:36 Stage Position Measurement, pos = -0.259700 m 10:11:38 Magnet Current, Imag = 10.9413 A Vtrans = 0.875306 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:11:38 Hall Probe Field Measurement, B = 0.000740 T 10:11:45 Stage moved to, position = -0.255000 10:11:47 Stage Position Measurement, pos = -0.255405 m 10:11:48 Magnet Current, Imag = 10.9414 A Vtrans = 0.875313 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:11:48 Hall Probe Field Measurement, B = 0.000770 T 10:11:55 Stage moved to, position = -0.250000 10:11:57 Stage Position Measurement, pos = -0.250420 m 10:11:58 Magnet Current, Imag = 10.9415 A Vtrans = 0.875318 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:11:59 Hall Probe Field Measurement, B = 0.000800 T 10:12:06 Stage moved to, position = -0.245000 10:12:07 Stage Position Measurement, pos = -0.245385 m 10:12:09 Magnet Current, Imag = 10.9416 A Vtrans = 0.875328 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:12:09 Hall Probe Field Measurement, B = 0.000830 T 10:12:16 Stage moved to, position = -0.240000 10:12:18 Stage Position Measurement, pos = -0.240405 m 10:12:19 Magnet Current, Imag = 10.9414 A Vtrans = 0.875314 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:12:19 Hall Probe Field Measurement, B = 0.000870 T 10:12:27 Stage moved to, position = -0.235000 10:12:28 Stage Position Measurement, pos = -0.235420 m 10:12:29 Magnet Current, Imag = 10.9414 A Vtrans = 0.875314 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:12:30 Hall Probe Field Measurement, B = 0.000900 T 10:12:37 Stage moved to, position = -0.230000 10:12:39 Stage Position Measurement, pos = -0.230395 m 10:12:40 Magnet Current, Imag = 10.9415 A Vtrans = 0.875319 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:12:40 Hall Probe Field Measurement, B = 0.000940 T 10:12:47 Stage moved to, position = -0.225000 10:12:49 Stage Position Measurement, pos = -0.225355 m 10:12:50 Magnet Current, Imag = 10.9413 A Vtrans = 0.875304 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:12:51 Hall Probe Field Measurement, B = 0.000980 T 10:12:58 Stage moved to, position = -0.220000 10:12:59 Stage Position Measurement, pos = -0.220375 m 10:13:00 Magnet Current, Imag = 10.9412 A Vtrans = 0.875292 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:01 Hall Probe Field Measurement, B = 0.001030 T 10:13:08 Stage moved to, position = -0.215000 10:13:10 Stage Position Measurement, pos = -0.215365 m 10:13:11 Magnet Current, Imag = 10.9412 A Vtrans = 0.875299 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:11 Hall Probe Field Measurement, B = 0.001060 T 10:13:18 Stage moved to, position = -0.210000 10:13:20 Stage Position Measurement, pos = -0.210325 m 10:13:21 Magnet Current, Imag = 10.9415 A Vtrans = 0.875321 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:22 Hall Probe Field Measurement, B = 0.001110 T 10:13:29 Stage moved to, position = -0.205000 10:13:30 Stage Position Measurement, pos = -0.205320 m 10:13:32 Magnet Current, Imag = 10.9416 A Vtrans = 0.875331 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:32 Hall Probe Field Measurement, B = 0.001160 T 10:13:39 Stage moved to, position = -0.200000 10:13:41 Stage Position Measurement, pos = -0.200315 m 10:13:42 Magnet Current, Imag = 10.9415 A Vtrans = 0.875318 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:43 Hall Probe Field Measurement, B = 0.001210 T 10:13:50 Stage moved to, position = -0.195000 10:13:51 Stage Position Measurement, pos = -0.195285 m 10:13:52 Magnet Current, Imag = 10.9419 A Vtrans = 0.875349 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:13:53 Hall Probe Field Measurement, B = 0.001260 T 10:14:00 Stage moved to, position = -0.190000 10:14:02 Stage Position Measurement, pos = -0.190230 m 10:14:03 Magnet Current, Imag = 10.9418 A Vtrans = 0.875344 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:03 Hall Probe Field Measurement, B = 0.001320 T 10:14:10 Stage moved to, position = -0.185000 10:14:12 Stage Position Measurement, pos = -0.185255 m 10:14:13 Magnet Current, Imag = 10.9415 A Vtrans = 0.875317 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:14 Hall Probe Field Measurement, B = 0.001370 T 10:14:21 Stage moved to, position = -0.180000 10:14:22 Stage Position Measurement, pos = -0.180255 m 10:14:24 Magnet Current, Imag = 10.9415 A Vtrans = 0.875321 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:24 Hall Probe Field Measurement, B = 0.001440 T 10:14:31 Stage moved to, position = -0.175000 10:14:33 Stage Position Measurement, pos = -0.175220 m 10:14:34 Magnet Current, Imag = 10.9415 A Vtrans = 0.875322 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:35 Hall Probe Field Measurement, B = 0.001500 T 10:14:42 Stage moved to, position = -0.170000 10:14:43 Stage Position Measurement, pos = -0.170155 m 10:14:45 Magnet Current, Imag = 10.9418 A Vtrans = 0.875343 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:45 Hall Probe Field Measurement, B = 0.001560 T 10:14:52 Stage moved to, position = -0.165000 10:14:54 Stage Position Measurement, pos = -0.165155 m 10:14:55 Magnet Current, Imag = 10.9412 A Vtrans = 0.875296 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:14:55 Hall Probe Field Measurement, B = 0.001620 T 10:15:03 Stage moved to, position = -0.160000 10:15:04 Stage Position Measurement, pos = -0.160135 m 10:15:05 Magnet Current, Imag = 10.9418 A Vtrans = 0.875342 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:06 Hall Probe Field Measurement, B = 0.001700 T 10:15:13 Stage moved to, position = -0.155000 10:15:15 Stage Position Measurement, pos = -0.155085 m 10:15:16 Magnet Current, Imag = 10.9418 A Vtrans = 0.875341 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:16 Hall Probe Field Measurement, B = 0.001760 T 10:15:23 Stage moved to, position = -0.150000 10:15:25 Stage Position Measurement, pos = -0.150130 m 10:15:26 Magnet Current, Imag = 10.9415 A Vtrans = 0.875317 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:27 Hall Probe Field Measurement, B = 0.001830 T 10:15:34 Stage moved to, position = -0.145000 10:15:35 Stage Position Measurement, pos = -0.145145 m 10:15:37 Magnet Current, Imag = 10.9415 A Vtrans = 0.875324 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:37 Hall Probe Field Measurement, B = 0.001910 T 10:15:44 Stage moved to, position = -0.140000 10:15:46 Stage Position Measurement, pos = -0.140155 m 10:15:47 Magnet Current, Imag = 10.9414 A Vtrans = 0.875314 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:47 Hall Probe Field Measurement, B = 0.001980 T 10:15:55 Stage moved to, position = -0.135000 10:15:56 Stage Position Measurement, pos = -0.135120 m 10:15:57 Magnet Current, Imag = 10.9416 A Vtrans = 0.875327 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:15:58 Hall Probe Field Measurement, B = 0.002060 T 10:16:05 Stage moved to, position = -0.130000 10:16:07 Stage Position Measurement, pos = -0.130160 m 10:16:08 Magnet Current, Imag = 10.9420 A Vtrans = 0.875363 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:16:08 Hall Probe Field Measurement, B = 0.002130 T 10:16:15 Stage moved to, position = -0.125000 10:16:17 Stage Position Measurement, pos = -0.125190 m 10:16:18 Magnet Current, Imag = 10.9421 A Vtrans = 0.875370 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:16:19 Hall Probe Field Measurement, B = 0.002210 T 10:16:26 Stage moved to, position = -0.120000 10:16:27 Stage Position Measurement, pos = -0.120160 m 10:16:29 Magnet Current, Imag = 10.9420 A Vtrans = 0.875361 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:16:29 Hall Probe Field Measurement, B = 0.002290 T 10:16:36 Stage moved to, position = -0.115000 10:16:38 Stage Position Measurement, pos = -0.115160 m 10:16:39 Magnet Current, Imag = 10.9419 A Vtrans = 0.875352 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:16:40 Hall Probe Field Measurement, B = 0.002370 T 10:16:47 Stage moved to, position = -0.110000 10:16:48 Stage Position Measurement, pos = -0.110180 m 10:16:49 Magnet Current, Imag = 10.9421 A Vtrans = 0.875365 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:16:51 Hall Probe Field Measurement, B = 0.002450 T 10:16:58 Stage moved to, position = -0.105000 10:17:00 Stage Position Measurement, pos = -0.105165 m 10:17:01 Magnet Current, Imag = 10.9420 A Vtrans = 0.875362 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:02 Hall Probe Field Measurement, B = 0.002530 T 10:17:09 Stage moved to, position = -0.100000 10:17:10 Stage Position Measurement, pos = -0.100125 m 10:17:12 Magnet Current, Imag = 10.9420 A Vtrans = 0.875360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:12 Hall Probe Field Measurement, B = 0.002600 T 10:17:19 Stage moved to, position = -0.095000 10:17:21 Stage Position Measurement, pos = -0.095145 m 10:17:22 Magnet Current, Imag = 10.9420 A Vtrans = 0.875356 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:22 Hall Probe Field Measurement, B = 0.002680 T 10:17:30 Stage moved to, position = -0.090000 10:17:31 Stage Position Measurement, pos = -0.090170 m 10:17:32 Magnet Current, Imag = 10.9418 A Vtrans = 0.875347 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:33 Hall Probe Field Measurement, B = 0.002750 T 10:17:40 Stage moved to, position = -0.085000 10:17:42 Stage Position Measurement, pos = -0.085150 m 10:17:43 Magnet Current, Imag = 10.9418 A Vtrans = 0.875347 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:43 Hall Probe Field Measurement, B = 0.002810 T 10:17:50 Stage moved to, position = -0.080000 10:17:52 Stage Position Measurement, pos = -0.080130 m 10:17:53 Magnet Current, Imag = 10.9418 A Vtrans = 0.875343 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:17:54 Hall Probe Field Measurement, B = 0.002880 T 10:18:01 Stage moved to, position = -0.075000 10:18:02 Stage Position Measurement, pos = -0.075165 m 10:18:04 Magnet Current, Imag = 10.9417 A Vtrans = 0.875335 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:04 Hall Probe Field Measurement, B = 0.002940 T 10:18:11 Stage moved to, position = -0.070000 10:18:13 Stage Position Measurement, pos = -0.070150 m 10:18:14 Magnet Current, Imag = 10.9418 A Vtrans = 0.875344 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:15 Hall Probe Field Measurement, B = 0.002980 T 10:18:22 Stage moved to, position = -0.065000 10:18:23 Stage Position Measurement, pos = -0.065100 m 10:18:25 Magnet Current, Imag = 10.9415 A Vtrans = 0.875321 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:25 Hall Probe Field Measurement, B = 0.003000 T 10:18:32 Stage moved to, position = -0.060000 10:18:34 Stage Position Measurement, pos = -0.060130 m 10:18:35 Magnet Current, Imag = 10.9415 A Vtrans = 0.875320 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:35 Hall Probe Field Measurement, B = 0.003010 T 10:18:43 Stage moved to, position = -0.055000 10:18:44 Stage Position Measurement, pos = -0.055130 m 10:18:45 Magnet Current, Imag = 10.9419 A Vtrans = 0.875349 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:46 Hall Probe Field Measurement, B = 0.002990 T 10:18:53 Stage moved to, position = -0.050000 10:18:55 Stage Position Measurement, pos = -0.050115 m 10:18:56 Magnet Current, Imag = 10.9417 A Vtrans = 0.875338 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:18:56 Hall Probe Field Measurement, B = 0.002900 T 10:19:03 Stage moved to, position = -0.045000 10:19:05 Stage Position Measurement, pos = -0.045095 m 10:19:06 Magnet Current, Imag = 10.9415 A Vtrans = 0.875320 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:07 Hall Probe Field Measurement, B = 0.002680 T 10:19:14 Stage moved to, position = -0.040000 10:19:15 Stage Position Measurement, pos = -0.040115 m 10:19:17 Magnet Current, Imag = 10.9417 A Vtrans = 0.875333 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:17 Hall Probe Field Measurement, B = 0.002190 T 10:19:24 Stage moved to, position = -0.035000 10:19:26 Stage Position Measurement, pos = -0.035100 m 10:19:27 Magnet Current, Imag = 10.9420 A Vtrans = 0.875360 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:27 Hall Probe Field Measurement, B = 0.001080 T 10:19:35 Stage moved to, position = -0.030000 10:19:36 Stage Position Measurement, pos = -0.030060 m 10:19:37 Magnet Current, Imag = 10.9419 A Vtrans = 0.875350 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:38 Hall Probe Field Measurement, B = -0.001440 T 10:19:45 Stage moved to, position = -0.025000 10:19:47 Stage Position Measurement, pos = -0.025065 m 10:19:48 Magnet Current, Imag = 10.9419 A Vtrans = 0.875351 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:48 Hall Probe Field Measurement, B = -0.006230 T 10:19:55 Stage moved to, position = -0.020000 10:19:57 Stage Position Measurement, pos = -0.020050 m 10:19:58 Magnet Current, Imag = 10.9415 A Vtrans = 0.875322 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:19:59 Hall Probe Field Measurement, B = -0.012840 T 10:20:06 Stage moved to, position = -0.015000 10:20:07 Stage Position Measurement, pos = -0.015035 m 10:20:09 Magnet Current, Imag = 10.9415 A Vtrans = 0.875324 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:20:09 Hall Probe Field Measurement, B = -0.018370 T 10:20:16 Stage moved to, position = -0.010000 10:20:18 Stage Position Measurement, pos = -0.009980 m 10:20:19 Magnet Current, Imag = 10.9416 A Vtrans = 0.875331 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:20:20 Hall Probe Field Measurement, B = -0.020610 T 10:20:27 Stage moved to, position = -0.005000 10:20:28 Stage Position Measurement, pos = -0.005015 m 10:20:30 Magnet Current, Imag = 10.9418 A Vtrans = 0.875346 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:20:30 Hall Probe Field Measurement, B = -0.020040 T 10:20:37 Stage moved to, position = 0.000000 10:20:39 Stage Position Measurement, pos = -0.000020 m 10:20:40 Magnet Current, Imag = 10.9417 A Vtrans = 0.875334 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:20:40 Hall Probe Field Measurement, B = -0.017930 T 10:20:48 Stage moved to, position = 0.005000 10:20:49 Stage Position Measurement, pos = 0.005010 m 10:20:50 Magnet Current, Imag = 10.9418 A Vtrans = 0.875343 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:20:51 Hall Probe Field Measurement, B = -0.015250 T 10:20:58 Stage moved to, position = 0.010000 10:21:00 Stage Position Measurement, pos = 0.010025 m 10:21:01 Magnet Current, Imag = 10.9416 A Vtrans = 0.875330 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:01 Hall Probe Field Measurement, B = -0.012630 T 10:21:08 Stage moved to, position = 0.015000 10:21:10 Stage Position Measurement, pos = 0.015000 m 10:21:11 Magnet Current, Imag = 10.9417 A Vtrans = 0.875338 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:12 Hall Probe Field Measurement, B = -0.010350 T 10:21:19 Stage moved to, position = 0.020000 10:21:20 Stage Position Measurement, pos = 0.020005 m 10:21:22 Magnet Current, Imag = 10.9418 A Vtrans = 0.875343 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:22 Hall Probe Field Measurement, B = -0.008440 T 10:21:29 Stage moved to, position = 0.025000 10:21:31 Stage Position Measurement, pos = 0.025045 m 10:21:32 Magnet Current, Imag = 10.9419 A Vtrans = 0.875348 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:33 Hall Probe Field Measurement, B = -0.006840 T 10:21:40 Stage moved to, position = 0.030000 10:21:41 Stage Position Measurement, pos = 0.030020 m 10:21:43 Magnet Current, Imag = 10.9420 A Vtrans = 0.875361 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:43 Hall Probe Field Measurement, B = -0.005510 T 10:21:50 Stage moved to, position = 0.035000 10:21:52 Stage Position Measurement, pos = 0.035005 m 10:21:53 Magnet Current, Imag = 10.9421 A Vtrans = 0.875364 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:21:53 Hall Probe Field Measurement, B = -0.004380 T 10:22:01 Stage moved to, position = 0.040000 10:22:02 Stage Position Measurement, pos = 0.040035 m 10:22:03 Magnet Current, Imag = 10.9422 A Vtrans = 0.875379 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:04 Hall Probe Field Measurement, B = -0.003410 T 10:22:11 Stage moved to, position = 0.045000 10:22:13 Stage Position Measurement, pos = 0.045075 m 10:22:14 Magnet Current, Imag = 10.9424 A Vtrans = 0.875391 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:14 Hall Probe Field Measurement, B = -0.002590 T 10:22:21 Stage moved to, position = 0.050000 10:22:23 Stage Position Measurement, pos = 0.050020 m 10:22:24 Magnet Current, Imag = 10.9424 A Vtrans = 0.875391 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:25 Hall Probe Field Measurement, B = -0.001890 T 10:22:32 Stage moved to, position = 0.055000 10:22:33 Stage Position Measurement, pos = 0.055040 m 10:22:35 Magnet Current, Imag = 10.9421 A Vtrans = 0.875372 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:35 Hall Probe Field Measurement, B = -0.001300 T 10:22:42 Stage moved to, position = 0.060000 10:22:44 Stage Position Measurement, pos = 0.060045 m 10:22:45 Magnet Current, Imag = 10.9422 A Vtrans = 0.875375 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:46 Hall Probe Field Measurement, B = -0.000790 T 10:22:53 Stage moved to, position = 0.065000 10:22:54 Stage Position Measurement, pos = 0.065025 m 10:22:56 Magnet Current, Imag = 10.9423 A Vtrans = 0.875386 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:22:56 Hall Probe Field Measurement, B = -0.000380 T 10:23:04 Stage moved to, position = 0.070000 10:23:05 Stage Position Measurement, pos = 0.070005 m 10:23:06 Magnet Current, Imag = 10.9422 A Vtrans = 0.875377 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:07 Hall Probe Field Measurement, B = -0.000030 T 10:23:14 Stage moved to, position = 0.075000 10:23:16 Stage Position Measurement, pos = 0.075025 m 10:23:17 Magnet Current, Imag = 10.9425 A Vtrans = 0.875399 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:17 Hall Probe Field Measurement, B = 0.000270 T 10:23:24 Stage moved to, position = 0.080000 10:23:26 Stage Position Measurement, pos = 0.080065 m 10:23:27 Magnet Current, Imag = 10.9425 A Vtrans = 0.875403 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:28 Hall Probe Field Measurement, B = 0.000510 T 10:23:35 Stage moved to, position = 0.085000 10:23:36 Stage Position Measurement, pos = 0.085020 m 10:23:38 Magnet Current, Imag = 10.9427 A Vtrans = 0.875414 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:38 Hall Probe Field Measurement, B = 0.000680 T 10:23:45 Stage moved to, position = 0.090000 10:23:47 Stage Position Measurement, pos = 0.090000 m 10:23:48 Magnet Current, Imag = 10.9425 A Vtrans = 0.875397 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:49 Hall Probe Field Measurement, B = 0.000830 T 10:23:56 Stage moved to, position = 0.095000 10:23:57 Stage Position Measurement, pos = 0.095025 m 10:23:59 Magnet Current, Imag = 10.9425 A Vtrans = 0.875403 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:23:59 Hall Probe Field Measurement, B = 0.000950 T 10:24:06 Stage moved to, position = 0.100000 10:24:08 Stage Position Measurement, pos = 0.100035 m 10:24:09 Magnet Current, Imag = 10.9424 A Vtrans = 0.875392 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:24:09 Hall Probe Field Measurement, B = 0.001040 T 10:24:17 Stage moved to, position = 0.105000 10:24:18 Stage Position Measurement, pos = 0.105025 m 10:24:19 Magnet Current, Imag = 10.9424 A Vtrans = 0.875392 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:24:20 Hall Probe Field Measurement, B = 0.001100 T 10:24:27 Stage moved to, position = 0.110000 10:24:29 Stage Position Measurement, pos = 0.110050 m 10:24:30 Magnet Current, Imag = 10.9424 A Vtrans = 0.875392 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:24:30 Hall Probe Field Measurement, B = 0.001150 T 10:24:37 Stage moved to, position = 0.115000 10:24:39 Stage Position Measurement, pos = 0.115095 m 10:24:40 Magnet Current, Imag = 10.9426 A Vtrans = 0.875412 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:24:41 Hall Probe Field Measurement, B = 0.001190 T 10:24:48 Stage moved to, position = 0.120000 10:24:49 Stage Position Measurement, pos = 0.120070 m 10:24:51 Magnet Current, Imag = 10.9425 A Vtrans = 0.875402 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:24:51 Hall Probe Field Measurement, B = 0.001200 T 10:24:58 Stage moved to, position = 0.125000 10:25:00 Stage Position Measurement, pos = 0.125055 m 10:25:01 Magnet Current, Imag = 10.9423 A Vtrans = 0.875385 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:02 Hall Probe Field Measurement, B = 0.001210 T 10:25:09 Stage moved to, position = 0.130000 10:25:10 Stage Position Measurement, pos = 0.130095 m 10:25:12 Magnet Current, Imag = 10.9423 A Vtrans = 0.875382 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:13 Hall Probe Field Measurement, B = 0.001210 T 10:25:21 Stage moved to, position = 0.135000 10:25:22 Stage Position Measurement, pos = 0.135105 m 10:25:23 Magnet Current, Imag = 10.9427 A Vtrans = 0.875416 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:24 Hall Probe Field Measurement, B = 0.001210 T 10:25:31 Stage moved to, position = 0.140000 10:25:33 Stage Position Measurement, pos = 0.140095 m 10:25:34 Magnet Current, Imag = 10.9422 A Vtrans = 0.875380 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:34 Hall Probe Field Measurement, B = 0.001200 T 10:25:41 Stage moved to, position = 0.145000 10:25:43 Stage Position Measurement, pos = 0.145135 m 10:25:44 Magnet Current, Imag = 10.9423 A Vtrans = 0.875386 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:45 Hall Probe Field Measurement, B = 0.001180 T 10:25:52 Stage moved to, position = 0.150000 10:25:54 Stage Position Measurement, pos = 0.150170 m 10:25:55 Magnet Current, Imag = 10.9424 A Vtrans = 0.875394 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:25:55 Hall Probe Field Measurement, B = 0.001160 T 10:26:02 Stage moved to, position = 0.155000 10:26:04 Stage Position Measurement, pos = 0.155170 m 10:26:05 Magnet Current, Imag = 10.9424 A Vtrans = 0.875391 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:06 Hall Probe Field Measurement, B = 0.001140 T 10:26:13 Stage moved to, position = 0.160000 10:26:14 Stage Position Measurement, pos = 0.160180 m 10:26:16 Magnet Current, Imag = 10.9427 A Vtrans = 0.875419 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:16 Hall Probe Field Measurement, B = 0.001110 T 10:26:23 Stage moved to, position = 0.165000 10:26:25 Stage Position Measurement, pos = 0.165205 m 10:26:26 Magnet Current, Imag = 10.9427 A Vtrans = 0.875414 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:26 Hall Probe Field Measurement, B = 0.001090 T 10:26:34 Stage moved to, position = 0.170000 10:26:35 Stage Position Measurement, pos = 0.170255 m 10:26:36 Magnet Current, Imag = 10.9427 A Vtrans = 0.875415 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:37 Hall Probe Field Measurement, B = 0.001050 T 10:26:44 Stage moved to, position = 0.175000 10:26:46 Stage Position Measurement, pos = 0.175220 m 10:26:47 Magnet Current, Imag = 10.9423 A Vtrans = 0.875383 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:47 Hall Probe Field Measurement, B = 0.001030 T 10:26:54 Stage moved to, position = 0.180000 10:26:56 Stage Position Measurement, pos = 0.180225 m 10:26:57 Magnet Current, Imag = 10.9426 A Vtrans = 0.875404 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:26:58 Hall Probe Field Measurement, B = 0.001000 T 10:27:05 Stage moved to, position = 0.185000 10:27:07 Stage Position Measurement, pos = 0.185255 m 10:27:08 Magnet Current, Imag = 10.9425 A Vtrans = 0.875403 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:27:08 Hall Probe Field Measurement, B = 0.000960 T 10:27:15 Stage moved to, position = 0.190000 10:27:17 Stage Position Measurement, pos = 0.190270 m 10:27:18 Magnet Current, Imag = 10.9424 A Vtrans = 0.875388 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:27:19 Hall Probe Field Measurement, B = 0.000940 T 10:27:26 Stage moved to, position = 0.195000 10:27:27 Stage Position Measurement, pos = 0.195245 m 10:27:29 Magnet Current, Imag = 10.9425 A Vtrans = 0.875402 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:27:29 Hall Probe Field Measurement, B = 0.000900 T 10:27:36 Stage moved to, position = 0.200000 10:27:38 Stage Position Measurement, pos = 0.200275 m 10:27:39 Magnet Current, Imag = 10.9426 A Vtrans = 0.875410 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:27:40 Hall Probe Field Measurement, B = 0.000880 T 10:27:47 Stage moved to, position = 0.205000 10:27:48 Stage Position Measurement, pos = 0.205335 m 10:27:50 Magnet Current, Imag = 10.9428 A Vtrans = 0.875423 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:27:50 Hall Probe Field Measurement, B = 0.000840 T 10:27:57 Stage moved to, position = 0.210000 10:27:59 Stage Position Measurement, pos = 0.210310 m 10:28:00 Magnet Current, Imag = 10.9424 A Vtrans = 0.875392 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:00 Hall Probe Field Measurement, B = 0.000820 T 10:28:08 Stage moved to, position = 0.215000 10:28:09 Stage Position Measurement, pos = 0.215285 m 10:28:10 Magnet Current, Imag = 10.9427 A Vtrans = 0.875414 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:11 Hall Probe Field Measurement, B = 0.000790 T 10:28:18 Stage moved to, position = 0.220000 10:28:20 Stage Position Measurement, pos = 0.220320 m 10:28:21 Magnet Current, Imag = 10.9425 A Vtrans = 0.875398 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:21 Hall Probe Field Measurement, B = 0.000770 T 10:28:28 Stage moved to, position = 0.225000 10:28:30 Stage Position Measurement, pos = 0.225335 m 10:28:31 Magnet Current, Imag = 10.9423 A Vtrans = 0.875387 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:32 Hall Probe Field Measurement, B = 0.000730 T 10:28:39 Stage moved to, position = 0.230000 10:28:40 Stage Position Measurement, pos = 0.230305 m 10:28:42 Magnet Current, Imag = 10.9424 A Vtrans = 0.875392 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:42 Hall Probe Field Measurement, B = 0.000700 T 10:28:49 Stage moved to, position = 0.235000 10:28:51 Stage Position Measurement, pos = 0.235315 m 10:28:52 Magnet Current, Imag = 10.9421 A Vtrans = 0.875372 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:28:53 Hall Probe Field Measurement, B = 0.000680 T 10:29:00 Stage moved to, position = 0.240000 10:29:01 Stage Position Measurement, pos = 0.240345 m 10:29:03 Magnet Current, Imag = 10.9422 A Vtrans = 0.875373 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:29:03 Hall Probe Field Measurement, B = 0.000670 T 10:29:10 Stage moved to, position = 0.245000 10:29:12 Stage Position Measurement, pos = 0.245330 m 10:29:13 Magnet Current, Imag = 10.9422 A Vtrans = 0.875374 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:29:13 Hall Probe Field Measurement, B = 0.000630 T 10:29:21 Stage moved to, position = 0.250000 10:29:22 Stage Position Measurement, pos = 0.250315 m 10:29:23 Magnet Current, Imag = 10.9423 A Vtrans = 0.875384 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:29:24 Hall Probe Field Measurement, B = 0.000620 T 10:29:31 Stage moved to, position = 0.255000 10:29:33 Stage Position Measurement, pos = 0.255320 m 10:29:34 Magnet Current, Imag = 10.9418 A Vtrans = 0.875347 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:29:34 Hall Probe Field Measurement, B = 0.000590 T 10:29:42 Stage moved to, position = 0.260000 10:29:43 Stage Position Measurement, pos = 0.260355 m 10:29:44 Magnet Current, Imag = 10.9420 A Vtrans = 0.875359 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 10:29:45 Hall Probe Field Measurement, B = 0.000570 T 10:30:43 Stage moved to, position = 0.000000 10:30:44 Magnet current ramping to 0.0000 A...