SLAC Magnetic Measurements Date: 02-14-2007 Time: 12:19:25 Project: Klystron Magnet Type: solenoid Magnet Name: PEPII-SN112 Serial Number: Run Number: 3 Measurement Device: B9900 Operator: sda Comment: Axial Hall scan, Collector End I2-11 = 36.6 A, I1 = 25.6 A, Buck = 0.0 A. Test Currents (A): 36.6 12:19:36 Stage Zeroed 12:19:36 MoveZ Devices: Move Device = SXDRIVE, Read Device = SXDRIVE 12:19:56 Move Stage, position = -0.050000 12:20:32 Hall Probe Zeroed 12:20:44 Hall Probe Type Being Used, type = B9900 12:20:51 Move Stage, position = -0.050000 12:20:53 Initial Zero Current Measurement, Imag_zero = 0.0000 A 12:20:56 Hall Probe Range Set, range = 4 12:20:56 Magnet current ramping to 36.6000 A... 12:21:42 Move Stage, position = -0.050000 12:21:42 Stage Position Measurement, pos = -0.0500000 m 12:21:43 Magnet Current, Imag = 36.7422 A Vtrans = 0.367422 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:44 Hall Probe Field Measurement, B = 0.001340 T 12:21:55 Move Stage, position = -0.025000 12:21:55 Stage Position Measurement, pos = -0.0250000 m 12:21:56 Magnet Current, Imag = 36.7429 A Vtrans = 0.367429 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:21:56 Hall Probe Field Measurement, B = 0.002140 T 12:22:07 Move Stage, position = 0.000000 12:22:07 Stage Position Measurement, pos = 0.0000000 m 12:22:09 Magnet Current, Imag = 36.7411 A Vtrans = 0.367411 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:09 Hall Probe Field Measurement, B = 0.004060 T 12:22:20 Move Stage, position = 0.025000 12:22:20 Stage Position Measurement, pos = 0.0250000 m 12:22:22 Magnet Current, Imag = 36.7445 A Vtrans = 0.367445 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:22 Hall Probe Field Measurement, B = 0.008250 T 12:22:33 Move Stage, position = 0.050000 12:22:33 Stage Position Measurement, pos = 0.0500000 m 12:22:35 Magnet Current, Imag = 36.7492 A Vtrans = 0.367492 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:35 Hall Probe Field Measurement, B = 0.015250 T 12:22:46 Move Stage, position = 0.075000 12:22:46 Stage Position Measurement, pos = 0.0750000 m 12:22:47 Magnet Current, Imag = 36.7534 A Vtrans = 0.367534 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:22:48 Hall Probe Field Measurement, B = 0.022200 T 12:22:59 Move Stage, position = 0.100000 12:22:59 Stage Position Measurement, pos = 0.1000000 m 12:23:00 Magnet Current, Imag = 36.7549 A Vtrans = 0.367549 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:01 Hall Probe Field Measurement, B = 0.026270 T 12:23:12 Move Stage, position = 0.125000 12:23:12 Stage Position Measurement, pos = 0.1250000 m 12:23:13 Magnet Current, Imag = 36.7557 A Vtrans = 0.367557 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:14 Hall Probe Field Measurement, B = 0.028020 T 12:23:24 Move Stage, position = 0.150000 12:23:25 Stage Position Measurement, pos = 0.1500000 m 12:23:26 Magnet Current, Imag = 36.7565 A Vtrans = 0.367565 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:26 Hall Probe Field Measurement, B = 0.028620 T 12:23:37 Move Stage, position = 0.175000 12:23:38 Stage Position Measurement, pos = 0.1750000 m 12:23:39 Magnet Current, Imag = 36.7584 A Vtrans = 0.367584 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:39 Hall Probe Field Measurement, B = 0.028750 T 12:23:50 Move Stage, position = 0.200000 12:23:50 Stage Position Measurement, pos = 0.2000000 m 12:23:52 Magnet Current, Imag = 36.7601 A Vtrans = 0.367601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:23:52 Hall Probe Field Measurement, B = 0.028740 T 12:24:03 Move Stage, position = 0.225000 12:24:03 Stage Position Measurement, pos = 0.2250000 m 12:24:05 Magnet Current, Imag = 36.7610 A Vtrans = 0.367610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:05 Hall Probe Field Measurement, B = 0.028700 T 12:24:16 Move Stage, position = 0.250000 12:24:16 Stage Position Measurement, pos = 0.2500000 m 12:24:17 Magnet Current, Imag = 36.7617 A Vtrans = 0.367617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:18 Hall Probe Field Measurement, B = 0.028740 T 12:24:29 Move Stage, position = 0.275000 12:24:29 Stage Position Measurement, pos = 0.2750000 m 12:24:30 Magnet Current, Imag = 36.7625 A Vtrans = 0.367625 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:31 Hall Probe Field Measurement, B = 0.028890 T 12:24:42 Move Stage, position = 0.300000 12:24:42 Stage Position Measurement, pos = 0.3000000 m 12:24:43 Magnet Current, Imag = 36.7644 A Vtrans = 0.367644 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:44 Hall Probe Field Measurement, B = 0.029120 T 12:24:55 Move Stage, position = 0.325000 12:24:55 Stage Position Measurement, pos = 0.3250000 m 12:24:56 Magnet Current, Imag = 36.7643 A Vtrans = 0.367643 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:24:56 Hall Probe Field Measurement, B = 0.029390 T 12:25:07 Move Stage, position = 0.350000 12:25:08 Stage Position Measurement, pos = 0.3500000 m 12:25:09 Magnet Current, Imag = 36.7657 A Vtrans = 0.367657 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:09 Hall Probe Field Measurement, B = 0.029660 T 12:25:20 Move Stage, position = 0.375000 12:25:20 Stage Position Measurement, pos = 0.3750000 m 12:25:22 Magnet Current, Imag = 36.7670 A Vtrans = 0.367670 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:22 Hall Probe Field Measurement, B = 0.029880 T 12:25:33 Move Stage, position = 0.400000 12:25:33 Stage Position Measurement, pos = 0.4000000 m 12:25:35 Magnet Current, Imag = 36.7675 A Vtrans = 0.367675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:35 Hall Probe Field Measurement, B = 0.030000 T 12:25:46 Move Stage, position = 0.425000 12:25:46 Stage Position Measurement, pos = 0.4250000 m 12:25:48 Magnet Current, Imag = 36.7675 A Vtrans = 0.367675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:25:48 Hall Probe Field Measurement, B = 0.030030 T 12:25:59 Move Stage, position = 0.450000 12:25:59 Stage Position Measurement, pos = 0.4500000 m 12:26:01 Magnet Current, Imag = 36.7676 A Vtrans = 0.367676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:01 Hall Probe Field Measurement, B = 0.029990 T 12:26:12 Move Stage, position = 0.475000 12:26:12 Stage Position Measurement, pos = 0.4750000 m 12:26:14 Magnet Current, Imag = 36.7679 A Vtrans = 0.367679 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:14 Hall Probe Field Measurement, B = 0.029890 T 12:26:25 Move Stage, position = 0.500000 12:26:25 Stage Position Measurement, pos = 0.5000000 m 12:26:27 Magnet Current, Imag = 36.7679 A Vtrans = 0.367679 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:27 Hall Probe Field Measurement, B = 0.029820 T 12:26:38 Move Stage, position = 0.525000 12:26:38 Stage Position Measurement, pos = 0.5250000 m 12:26:40 Magnet Current, Imag = 36.7688 A Vtrans = 0.367688 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:40 Hall Probe Field Measurement, B = 0.029810 T 12:26:51 Move Stage, position = 0.550000 12:26:51 Stage Position Measurement, pos = 0.5500000 m 12:26:52 Magnet Current, Imag = 36.7695 A Vtrans = 0.367695 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:26:53 Hall Probe Field Measurement, B = 0.029880 T 12:27:04 Move Stage, position = 0.575000 12:27:04 Stage Position Measurement, pos = 0.5750000 m 12:27:05 Magnet Current, Imag = 36.7703 A Vtrans = 0.367703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:06 Hall Probe Field Measurement, B = 0.030030 T 12:27:17 Move Stage, position = 0.600000 12:27:17 Stage Position Measurement, pos = 0.6000000 m 12:27:18 Magnet Current, Imag = 36.7703 A Vtrans = 0.367703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:19 Hall Probe Field Measurement, B = 0.030220 T 12:27:30 Move Stage, position = 0.625000 12:27:30 Stage Position Measurement, pos = 0.6250000 m 12:27:31 Magnet Current, Imag = 36.7706 A Vtrans = 0.367706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:32 Hall Probe Field Measurement, B = 0.030380 T 12:27:43 Move Stage, position = 0.650000 12:27:43 Stage Position Measurement, pos = 0.6500000 m 12:27:44 Magnet Current, Imag = 36.7704 A Vtrans = 0.367704 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:45 Hall Probe Field Measurement, B = 0.030530 T 12:27:55 Move Stage, position = 0.675000 12:27:56 Stage Position Measurement, pos = 0.6750000 m 12:27:57 Magnet Current, Imag = 36.7713 A Vtrans = 0.367713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:27:57 Hall Probe Field Measurement, B = 0.030570 T 12:28:08 Move Stage, position = 0.700000 12:28:08 Stage Position Measurement, pos = 0.7000000 m 12:28:10 Magnet Current, Imag = 36.7720 A Vtrans = 0.367720 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:12 Hall Probe Field Measurement, B = 0.030540 T 12:28:23 Move Stage, position = 0.725000 12:28:23 Stage Position Measurement, pos = 0.7250000 m 12:28:24 Magnet Current, Imag = 36.7730 A Vtrans = 0.367730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:25 Hall Probe Field Measurement, B = 0.030440 T 12:28:36 Move Stage, position = 0.750000 12:28:36 Stage Position Measurement, pos = 0.7500000 m 12:28:37 Magnet Current, Imag = 36.7731 A Vtrans = 0.367731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:38 Hall Probe Field Measurement, B = 0.030290 T 12:28:48 Move Stage, position = 0.775000 12:28:49 Stage Position Measurement, pos = 0.7750000 m 12:28:50 Magnet Current, Imag = 36.7732 A Vtrans = 0.367732 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:28:50 Hall Probe Field Measurement, B = 0.030160 T 12:29:01 Move Stage, position = 0.800000 12:29:02 Stage Position Measurement, pos = 0.8000000 m 12:29:03 Magnet Current, Imag = 36.7738 A Vtrans = 0.367738 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:03 Hall Probe Field Measurement, B = 0.030110 T 12:29:14 Move Stage, position = 0.825000 12:29:14 Stage Position Measurement, pos = 0.8250000 m 12:29:16 Magnet Current, Imag = 36.7736 A Vtrans = 0.367736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:16 Hall Probe Field Measurement, B = 0.030120 T 12:29:27 Move Stage, position = 0.850000 12:29:27 Stage Position Measurement, pos = 0.8500000 m 12:29:29 Magnet Current, Imag = 36.7741 A Vtrans = 0.367741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:29 Hall Probe Field Measurement, B = 0.030220 T 12:29:40 Move Stage, position = 0.875000 12:29:40 Stage Position Measurement, pos = 0.8750000 m 12:29:42 Magnet Current, Imag = 36.7738 A Vtrans = 0.367738 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:42 Hall Probe Field Measurement, B = 0.030350 T 12:29:53 Move Stage, position = 0.900000 12:29:53 Stage Position Measurement, pos = 0.9000000 m 12:29:55 Magnet Current, Imag = 36.7752 A Vtrans = 0.367752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:29:55 Hall Probe Field Measurement, B = 0.030500 T 12:30:06 Move Stage, position = 0.925000 12:30:06 Stage Position Measurement, pos = 0.9250000 m 12:30:08 Magnet Current, Imag = 36.7752 A Vtrans = 0.367752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:08 Hall Probe Field Measurement, B = 0.030580 T 12:30:19 Move Stage, position = 0.950000 12:30:19 Stage Position Measurement, pos = 0.9500000 m 12:30:20 Magnet Current, Imag = 36.7648 A Vtrans = 0.367648 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:21 Hall Probe Field Measurement, B = 0.030600 T 12:30:32 Move Stage, position = 0.975000 12:30:32 Stage Position Measurement, pos = 0.9750000 m 12:30:33 Magnet Current, Imag = 36.7568 A Vtrans = 0.367568 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:34 Hall Probe Field Measurement, B = 0.030520 T 12:30:45 Move Stage, position = 1.000000 12:30:45 Stage Position Measurement, pos = 1.0000000 m 12:30:46 Magnet Current, Imag = 36.7556 A Vtrans = 0.367556 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:30:47 Hall Probe Field Measurement, B = 0.030350 T 12:30:58 Move Stage, position = 1.025000 12:30:58 Stage Position Measurement, pos = 1.0250000 m 12:30:59 Magnet Current, Imag = 36.7561 A Vtrans = 0.367561 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:00 Hall Probe Field Measurement, B = 0.030180 T 12:31:11 Move Stage, position = 1.050000 12:31:11 Stage Position Measurement, pos = 1.0500000 m 12:31:12 Magnet Current, Imag = 36.7571 A Vtrans = 0.367571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:13 Hall Probe Field Measurement, B = 0.030030 T 12:31:23 Move Stage, position = 1.075000 12:31:24 Stage Position Measurement, pos = 1.0750000 m 12:31:25 Magnet Current, Imag = 36.7591 A Vtrans = 0.367591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:25 Hall Probe Field Measurement, B = 0.029950 T 12:31:36 Move Stage, position = 1.100000 12:31:36 Stage Position Measurement, pos = 1.1000000 m 12:31:38 Magnet Current, Imag = 36.7694 A Vtrans = 0.367694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:38 Hall Probe Field Measurement, B = 0.029950 T 12:31:49 Move Stage, position = 1.125000 12:31:49 Stage Position Measurement, pos = 1.1250000 m 12:31:51 Magnet Current, Imag = 36.7752 A Vtrans = 0.367752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:31:51 Hall Probe Field Measurement, B = 0.030030 T 12:32:02 Move Stage, position = 1.150000 12:32:02 Stage Position Measurement, pos = 1.1500000 m 12:32:04 Magnet Current, Imag = 36.7734 A Vtrans = 0.367734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:06 Hall Probe Field Measurement, B = 0.030180 T 12:32:16 Move Stage, position = 1.175000 12:32:17 Stage Position Measurement, pos = 1.1750000 m 12:32:18 Magnet Current, Imag = 36.7725 A Vtrans = 0.367725 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:18 Hall Probe Field Measurement, B = 0.030330 T 12:32:29 Move Stage, position = 1.200000 12:32:30 Stage Position Measurement, pos = 1.2000000 m 12:32:31 Magnet Current, Imag = 36.7623 A Vtrans = 0.367623 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:31 Hall Probe Field Measurement, B = 0.030440 T 12:32:42 Move Stage, position = 1.225000 12:32:42 Stage Position Measurement, pos = 1.2250000 m 12:32:44 Magnet Current, Imag = 36.7565 A Vtrans = 0.367565 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:44 Hall Probe Field Measurement, B = 0.030460 T 12:32:55 Move Stage, position = 1.250000 12:32:55 Stage Position Measurement, pos = 1.2500000 m 12:32:57 Magnet Current, Imag = 36.7567 A Vtrans = 0.367567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:32:57 Hall Probe Field Measurement, B = 0.030410 T 12:33:08 Move Stage, position = 1.275000 12:33:08 Stage Position Measurement, pos = 1.2750000 m 12:33:10 Magnet Current, Imag = 36.7571 A Vtrans = 0.367571 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:10 Hall Probe Field Measurement, B = 0.030290 T 12:33:21 Move Stage, position = 1.300000 12:33:21 Stage Position Measurement, pos = 1.3000000 m 12:33:22 Magnet Current, Imag = 36.7567 A Vtrans = 0.367567 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:23 Hall Probe Field Measurement, B = 0.030110 T 12:33:34 Move Stage, position = 1.325000 12:33:34 Stage Position Measurement, pos = 1.3250000 m 12:33:35 Magnet Current, Imag = 36.7610 A Vtrans = 0.367610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:36 Hall Probe Field Measurement, B = 0.029960 T 12:33:47 Move Stage, position = 1.350000 12:33:47 Stage Position Measurement, pos = 1.3500000 m 12:33:48 Magnet Current, Imag = 36.7642 A Vtrans = 0.367642 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:33:49 Hall Probe Field Measurement, B = 0.029880 T 12:34:00 Move Stage, position = 1.375000 12:34:00 Stage Position Measurement, pos = 1.3750000 m 12:34:01 Magnet Current, Imag = 36.7677 A Vtrans = 0.367677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:02 Hall Probe Field Measurement, B = 0.029870 T 12:34:13 Move Stage, position = 1.400000 12:34:13 Stage Position Measurement, pos = 1.4000000 m 12:34:14 Magnet Current, Imag = 36.7680 A Vtrans = 0.367680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:15 Hall Probe Field Measurement, B = 0.029960 T 12:34:25 Move Stage, position = 1.425000 12:34:26 Stage Position Measurement, pos = 1.4250000 m 12:34:27 Magnet Current, Imag = 36.7726 A Vtrans = 0.367726 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:27 Hall Probe Field Measurement, B = 0.030110 T 12:34:38 Move Stage, position = 1.450000 12:34:39 Stage Position Measurement, pos = 1.4500000 m 12:34:40 Magnet Current, Imag = 36.7721 A Vtrans = 0.367721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:40 Hall Probe Field Measurement, B = 0.030270 T 12:34:51 Move Stage, position = 1.475000 12:34:51 Stage Position Measurement, pos = 1.4750000 m 12:34:53 Magnet Current, Imag = 36.7730 A Vtrans = 0.367730 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:34:53 Hall Probe Field Measurement, B = 0.030410 T 12:35:04 Move Stage, position = 1.500000 12:35:04 Stage Position Measurement, pos = 1.5000000 m 12:35:06 Magnet Current, Imag = 36.7732 A Vtrans = 0.367732 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:06 Hall Probe Field Measurement, B = 0.030460 T 12:35:17 Move Stage, position = 1.525000 12:35:17 Stage Position Measurement, pos = 1.5250000 m 12:35:19 Magnet Current, Imag = 36.7741 A Vtrans = 0.367741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:19 Hall Probe Field Measurement, B = 0.030440 T 12:35:30 Move Stage, position = 1.550000 12:35:30 Stage Position Measurement, pos = 1.5500000 m 12:35:32 Magnet Current, Imag = 36.7747 A Vtrans = 0.367747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:32 Hall Probe Field Measurement, B = 0.030330 T 12:35:43 Move Stage, position = 1.575000 12:35:43 Stage Position Measurement, pos = 1.5750000 m 12:35:44 Magnet Current, Imag = 36.7748 A Vtrans = 0.367748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:45 Hall Probe Field Measurement, B = 0.030160 T 12:35:56 Move Stage, position = 1.600000 12:35:56 Stage Position Measurement, pos = 1.6000000 m 12:35:57 Magnet Current, Imag = 36.7751 A Vtrans = 0.367751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:35:59 Hall Probe Field Measurement, B = 0.030010 T 12:36:10 Move Stage, position = 1.625000 12:36:10 Stage Position Measurement, pos = 1.6250000 m 12:36:11 Magnet Current, Imag = 36.7750 A Vtrans = 0.367750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:11 Hall Probe Field Measurement, B = 0.029910 T 12:36:22 Move Stage, position = 1.650000 12:36:23 Stage Position Measurement, pos = 1.6500000 m 12:36:24 Magnet Current, Imag = 36.7749 A Vtrans = 0.367749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:24 Hall Probe Field Measurement, B = 0.029890 T 12:36:35 Move Stage, position = 1.675000 12:36:35 Stage Position Measurement, pos = 1.6750000 m 12:36:37 Magnet Current, Imag = 36.7753 A Vtrans = 0.367753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:37 Hall Probe Field Measurement, B = 0.029960 T 12:36:48 Move Stage, position = 1.700000 12:36:48 Stage Position Measurement, pos = 1.7000000 m 12:36:50 Magnet Current, Imag = 36.7756 A Vtrans = 0.367756 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:36:50 Hall Probe Field Measurement, B = 0.030100 T 12:37:01 Move Stage, position = 1.725000 12:37:01 Stage Position Measurement, pos = 1.7250000 m 12:37:03 Magnet Current, Imag = 36.7758 A Vtrans = 0.367758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:03 Hall Probe Field Measurement, B = 0.030250 T 12:37:14 Move Stage, position = 1.750000 12:37:14 Stage Position Measurement, pos = 1.7500000 m 12:37:15 Magnet Current, Imag = 36.7759 A Vtrans = 0.367759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:16 Hall Probe Field Measurement, B = 0.030380 T 12:37:27 Move Stage, position = 1.775000 12:37:27 Stage Position Measurement, pos = 1.7750000 m 12:37:28 Magnet Current, Imag = 36.7761 A Vtrans = 0.367761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:29 Hall Probe Field Measurement, B = 0.030450 T 12:37:40 Move Stage, position = 1.800000 12:37:40 Stage Position Measurement, pos = 1.8000000 m 12:37:41 Magnet Current, Imag = 36.7760 A Vtrans = 0.367760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:42 Hall Probe Field Measurement, B = 0.030410 T 12:37:53 Move Stage, position = 1.825000 12:37:53 Stage Position Measurement, pos = 1.8250000 m 12:37:54 Magnet Current, Imag = 36.7762 A Vtrans = 0.367762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:37:55 Hall Probe Field Measurement, B = 0.030290 T 12:38:05 Move Stage, position = 1.850000 12:38:06 Stage Position Measurement, pos = 1.8500000 m 12:38:07 Magnet Current, Imag = 36.7765 A Vtrans = 0.367765 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:07 Hall Probe Field Measurement, B = 0.030120 T 12:38:18 Move Stage, position = 1.875000 12:38:19 Stage Position Measurement, pos = 1.8750000 m 12:38:20 Magnet Current, Imag = 36.7763 A Vtrans = 0.367763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:20 Hall Probe Field Measurement, B = 0.029960 T 12:38:31 Move Stage, position = 1.900000 12:38:31 Stage Position Measurement, pos = 1.9000000 m 12:38:33 Magnet Current, Imag = 36.7760 A Vtrans = 0.367760 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 12:38:33 Hall Probe Field Measurement, B = 0.029840 T 12:44:59 Move Stage, position = 0.000000 12:45:05 Magnet current ramping to 0.0000 A...