SLAC Magnetic Measurements Date: 01-28-2010 Time: 14:32:06 Project: FACET Magnet Type: Quad Magnet Name: QS1 Serial Number: Type2.13Q38.31 Run Number: 2 Measurement Device: 10 wire Operator: sda Comment: Intgegrated Gradient using stretched wire at 475 amps for coil calibration. Standardization: 3 cycles from 10.0 A to 500.0 A to 10.0 A Test Currents (A): 475.0 475.0 475.0 Integrated Gradient Distance the wire was to be moved = 0.005000 m Number of turns in the wire = 10 Number of measurements for averaging = 7 Imag sigImag GL sigGL GL/I sigGL/I (A) (A) (T) (T) (T/A) (T/A) ---------+--------- ----------+---------- ----------+---------- 475.026 0.036 38.66827 0.00188 0.081402 0.000004 475.018 0.065 38.66586 0.00272 0.081399 0.000006 475.018 0.096 38.66376 0.00309 0.081394 0.000007