SLAC Magnetic Measurements Date: 03-26-2019 Time: 13:59:47 Project: FACET_II Magnet Type: Dipole Magnet Name: BCX14808 Serial Number: Center_2 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated Field vs current 0-200-0 A in 20 A steps. Warmup for 1 hr at 200 A. BL vs X at 200 A. Standardization for MAIN: 10 cycles from 0.0 A to 200.0 A to 0.0 A Test Currents for MAIN (A): 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 180.00 200.00 180.00 160.00 140.00 120.00 100.00 80.00 60.00 40.00 20.00 0.00 200.00 14:00:21 Position moved: 0.000000 m 14:00:25 Magnet Current for MAIN, Imag = -0.0054 A Vtrans = -0.000054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:25 Magnet Current for MAIN, Imag = -0.0055 A Vtrans = -0.000055 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:26 Magnet Current for MAIN, Imag = -0.0054 A Vtrans = -0.000054 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:27 Magnet Current for MAIN, Imag = -0.0055 A Vtrans = -0.000055 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 14:00:27 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0055 +- 0.0000 A 14:00:45 Initial Zero Current Measurement for MAIN, Imag_zero = -0.00545235 A 14:00:45 Ambient Measurement Device(s) Being Used, type = None 14:00:45 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 14:00:46 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 14:00:46 XMAG Device(s) Being Used, type = None 14:00:46 Ambient Measurement Device(s) Being Used, type = HP34970 14:00:46 Magnet system MAIN current ramping to 200.0000 A... 14:01:43 Magnet Current for MAIN, Imag = 200.1336 A Vtrans = 2.001282 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:01:44 MAIN (V) Voltage Measurement, V = 31.256729 V 14:01:44 Temperature Measurement, Probe Number = 0, T = 22.370000 C 14:01:45 Temperature Measurement, Probe Number = 1, T = 29.306000 C 14:01:46 Temperature Measurement, Probe Number = 2, T = 19.220000 C 14:01:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313507 V 14:01:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313507 (V, A, ohm, ...), Measured Value = 28.243158 (C, atm, Hz, ...) 14:01:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.661135 V 14:01:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.661135 (V, A, ohm, ...), Measured Value = 33.071321 (C, atm, Hz, ...) 14:01:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659473 V 14:01:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659473 (V, A, ohm, ...), Measured Value = 124.460445 (C, atm, Hz, ...) 14:01:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106051 V 14:01:48 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106051 (V, A, ohm, ...), Measured Value = 7.953848 (C, atm, Hz, ...) 14:01:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.13 P1 = MAIN (V), Value = 31.26 P2 = Magnet Core, Value = 22.37 P3 = Coil, Value = 29.31 P4 = Ambient Temp (C), Value = 19.22 P5 = Supply Temp(C), Value = 28.24 P6 = Return Temp(C), Value = 33.07 P7 = Supply Pres(psi), Value = 124.46 P8 = Return Pres(psi), Value = 7.95 14:02:49 Magnet Current for MAIN, Imag = 200.1358 A Vtrans = 2.001303 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:02:50 MAIN (V) Voltage Measurement, V = 31.429580 V 14:02:50 Temperature Measurement, Probe Number = 0, T = 22.369000 C 14:02:51 Temperature Measurement, Probe Number = 1, T = 29.186000 C 14:02:52 Temperature Measurement, Probe Number = 2, T = 19.190000 C 14:02:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313941 V 14:02:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313941 (V, A, ohm, ...), Measured Value = 28.249178 (C, atm, Hz, ...) 14:02:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.626284 V 14:02:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.626284 (V, A, ohm, ...), Measured Value = 32.587272 (C, atm, Hz, ...) 14:02:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666854 V 14:02:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666854 (V, A, ohm, ...), Measured Value = 125.014027 (C, atm, Hz, ...) 14:02:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105993 V 14:02:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105993 (V, A, ohm, ...), Measured Value = 7.949467 (C, atm, Hz, ...) 14:02:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.43 P2 = Magnet Core, Value = 22.37 P3 = Coil, Value = 29.19 P4 = Ambient Temp (C), Value = 19.19 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 32.59 P7 = Supply Pres(psi), Value = 125.01 P8 = Return Pres(psi), Value = 7.95 14:03:55 Magnet Current for MAIN, Imag = 200.1358 A Vtrans = 2.001303 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:03:56 MAIN (V) Voltage Measurement, V = 31.541171 V 14:03:56 Temperature Measurement, Probe Number = 0, T = 22.375000 C 14:03:57 Temperature Measurement, Probe Number = 1, T = 29.415000 C 14:03:58 Temperature Measurement, Probe Number = 2, T = 19.153000 C 14:03:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.314125 V 14:03:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.314125 (V, A, ohm, ...), Measured Value = 28.251737 (C, atm, Hz, ...) 14:03:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.601704 V 14:03:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.601704 (V, A, ohm, ...), Measured Value = 32.245882 (C, atm, Hz, ...) 14:04:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.673545 V 14:04:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.673545 (V, A, ohm, ...), Measured Value = 125.515845 (C, atm, Hz, ...) 14:04:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105884 V 14:04:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105884 (V, A, ohm, ...), Measured Value = 7.941270 (C, atm, Hz, ...) 14:04:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.54 P2 = Magnet Core, Value = 22.38 P3 = Coil, Value = 29.41 P4 = Ambient Temp (C), Value = 19.15 P5 = Supply Temp(C), Value = 28.25 P6 = Return Temp(C), Value = 32.25 P7 = Supply Pres(psi), Value = 125.52 P8 = Return Pres(psi), Value = 7.94 14:05:01 Magnet Current for MAIN, Imag = 200.1370 A Vtrans = 2.001316 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:05:02 MAIN (V) Voltage Measurement, V = 31.603786 V 14:05:03 Temperature Measurement, Probe Number = 0, T = 22.381000 C 14:05:03 Temperature Measurement, Probe Number = 1, T = 29.766000 C 14:05:04 Temperature Measurement, Probe Number = 2, T = 19.033000 C 14:05:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313055 V 14:05:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313055 (V, A, ohm, ...), Measured Value = 28.236874 (C, atm, Hz, ...) 14:05:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.592417 V 14:05:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.592417 (V, A, ohm, ...), Measured Value = 32.116903 (C, atm, Hz, ...) 14:05:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660183 V 14:05:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660183 (V, A, ohm, ...), Measured Value = 124.513732 (C, atm, Hz, ...) 14:05:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105693 V 14:05:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105693 (V, A, ohm, ...), Measured Value = 7.926967 (C, atm, Hz, ...) 14:05:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.60 P2 = Magnet Core, Value = 22.38 P3 = Coil, Value = 29.77 P4 = Ambient Temp (C), Value = 19.03 P5 = Supply Temp(C), Value = 28.24 P6 = Return Temp(C), Value = 32.12 P7 = Supply Pres(psi), Value = 124.51 P8 = Return Pres(psi), Value = 7.93 14:06:07 Magnet Current for MAIN, Imag = 200.1372 A Vtrans = 2.001317 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:06:08 MAIN (V) Voltage Measurement, V = 31.637576 V 14:06:09 Temperature Measurement, Probe Number = 0, T = 22.390000 C 14:06:09 Temperature Measurement, Probe Number = 1, T = 30.053000 C 14:06:10 Temperature Measurement, Probe Number = 2, T = 19.023000 C 14:06:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.313422 V 14:06:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.313422 (V, A, ohm, ...), Measured Value = 28.241975 (C, atm, Hz, ...) 14:06:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.596756 V 14:06:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.596756 (V, A, ohm, ...), Measured Value = 32.177172 (C, atm, Hz, ...) 14:06:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657857 V 14:06:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657857 (V, A, ohm, ...), Measured Value = 124.339275 (C, atm, Hz, ...) 14:06:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105726 V 14:06:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105726 (V, A, ohm, ...), Measured Value = 7.929442 (C, atm, Hz, ...) 14:06:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.64 P2 = Magnet Core, Value = 22.39 P3 = Coil, Value = 30.05 P4 = Ambient Temp (C), Value = 19.02 P5 = Supply Temp(C), Value = 28.24 P6 = Return Temp(C), Value = 32.18 P7 = Supply Pres(psi), Value = 124.34 P8 = Return Pres(psi), Value = 7.93 14:07:13 Magnet Current for MAIN, Imag = 200.1373 A Vtrans = 2.001318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:07:14 MAIN (V) Voltage Measurement, V = 31.655861 V 14:07:15 Temperature Measurement, Probe Number = 0, T = 22.416000 C 14:07:15 Temperature Measurement, Probe Number = 1, T = 30.246000 C 14:07:16 Temperature Measurement, Probe Number = 2, T = 19.092000 C 14:07:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.314576 V 14:07:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.314576 (V, A, ohm, ...), Measured Value = 28.258004 (C, atm, Hz, ...) 14:07:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.608364 V 14:07:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.608364 (V, A, ohm, ...), Measured Value = 32.338387 (C, atm, Hz, ...) 14:07:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655849 V 14:07:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655849 (V, A, ohm, ...), Measured Value = 124.188652 (C, atm, Hz, ...) 14:07:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105716 V 14:07:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105716 (V, A, ohm, ...), Measured Value = 7.928685 (C, atm, Hz, ...) 14:07:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.66 P2 = Magnet Core, Value = 22.42 P3 = Coil, Value = 30.25 P4 = Ambient Temp (C), Value = 19.09 P5 = Supply Temp(C), Value = 28.26 P6 = Return Temp(C), Value = 32.34 P7 = Supply Pres(psi), Value = 124.19 P8 = Return Pres(psi), Value = 7.93 14:08:19 Magnet Current for MAIN, Imag = 200.1414 A Vtrans = 2.001359 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:08:20 MAIN (V) Voltage Measurement, V = 31.665750 V 14:08:21 Temperature Measurement, Probe Number = 0, T = 22.447000 C 14:08:21 Temperature Measurement, Probe Number = 1, T = 30.366000 C 14:08:22 Temperature Measurement, Probe Number = 2, T = 19.132000 C 14:08:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.315593 V 14:08:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.315593 (V, A, ohm, ...), Measured Value = 28.272128 (C, atm, Hz, ...) 14:08:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.620578 V 14:08:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.620578 (V, A, ohm, ...), Measured Value = 32.508022 (C, atm, Hz, ...) 14:08:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.645198 V 14:08:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645198 (V, A, ohm, ...), Measured Value = 123.389880 (C, atm, Hz, ...) 14:08:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105557 V 14:08:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105557 (V, A, ohm, ...), Measured Value = 7.916768 (C, atm, Hz, ...) 14:08:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.67 P2 = Magnet Core, Value = 22.45 P3 = Coil, Value = 30.37 P4 = Ambient Temp (C), Value = 19.13 P5 = Supply Temp(C), Value = 28.27 P6 = Return Temp(C), Value = 32.51 P7 = Supply Pres(psi), Value = 123.39 P8 = Return Pres(psi), Value = 7.92 14:09:25 Magnet Current for MAIN, Imag = 200.1414 A Vtrans = 2.001359 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:09:26 MAIN (V) Voltage Measurement, V = 31.671365 V 14:09:27 Temperature Measurement, Probe Number = 0, T = 22.478000 C 14:09:27 Temperature Measurement, Probe Number = 1, T = 30.440000 C 14:09:28 Temperature Measurement, Probe Number = 2, T = 19.161000 C 14:09:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.316433 V 14:09:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316433 (V, A, ohm, ...), Measured Value = 28.283797 (C, atm, Hz, ...) 14:09:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.632982 V 14:09:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.632982 (V, A, ohm, ...), Measured Value = 32.680307 (C, atm, Hz, ...) 14:09:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661523 V 14:09:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661523 (V, A, ohm, ...), Measured Value = 124.614210 (C, atm, Hz, ...) 14:09:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106002 V 14:09:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106002 (V, A, ohm, ...), Measured Value = 7.950135 (C, atm, Hz, ...) 14:09:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.67 P2 = Magnet Core, Value = 22.48 P3 = Coil, Value = 30.44 P4 = Ambient Temp (C), Value = 19.16 P5 = Supply Temp(C), Value = 28.28 P6 = Return Temp(C), Value = 32.68 P7 = Supply Pres(psi), Value = 124.61 P8 = Return Pres(psi), Value = 7.95 14:10:31 Magnet Current for MAIN, Imag = 200.1400 A Vtrans = 2.001345 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:10:32 MAIN (V) Voltage Measurement, V = 31.674466 V 14:10:33 Temperature Measurement, Probe Number = 0, T = 22.509000 C 14:10:33 Temperature Measurement, Probe Number = 1, T = 30.493000 C 14:10:34 Temperature Measurement, Probe Number = 2, T = 19.211000 C 14:10:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.316801 V 14:10:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.316801 (V, A, ohm, ...), Measured Value = 28.288899 (C, atm, Hz, ...) 14:10:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.644188 V 14:10:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.644188 (V, A, ohm, ...), Measured Value = 32.835943 (C, atm, Hz, ...) 14:10:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654640 V 14:10:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654640 (V, A, ohm, ...), Measured Value = 124.098000 (C, atm, Hz, ...) 14:10:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106069 V 14:10:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106069 (V, A, ohm, ...), Measured Value = 7.955183 (C, atm, Hz, ...) 14:10:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.67 P2 = Magnet Core, Value = 22.51 P3 = Coil, Value = 30.49 P4 = Ambient Temp (C), Value = 19.21 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 32.84 P7 = Supply Pres(psi), Value = 124.10 P8 = Return Pres(psi), Value = 7.96 14:11:37 Magnet Current for MAIN, Imag = 200.1388 A Vtrans = 2.001334 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:11:38 MAIN (V) Voltage Measurement, V = 31.676635 V 14:11:39 Temperature Measurement, Probe Number = 0, T = 22.533000 C 14:11:39 Temperature Measurement, Probe Number = 1, T = 30.571000 C 14:11:40 Temperature Measurement, Probe Number = 2, T = 19.226000 C 14:11:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317608 V 14:11:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317608 (V, A, ohm, ...), Measured Value = 28.300110 (C, atm, Hz, ...) 14:11:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.654833 V 14:11:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.654833 (V, A, ohm, ...), Measured Value = 32.983794 (C, atm, Hz, ...) 14:11:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667254 V 14:11:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667254 (V, A, ohm, ...), Measured Value = 125.044058 (C, atm, Hz, ...) 14:11:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106302 V 14:11:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106302 (V, A, ohm, ...), Measured Value = 7.972627 (C, atm, Hz, ...) 14:11:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.53 P3 = Coil, Value = 30.57 P4 = Ambient Temp (C), Value = 19.23 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 32.98 P7 = Supply Pres(psi), Value = 125.04 P8 = Return Pres(psi), Value = 7.97 14:12:43 Magnet Current for MAIN, Imag = 200.1386 A Vtrans = 2.001331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:12:44 MAIN (V) Voltage Measurement, V = 31.678039 V 14:12:45 Temperature Measurement, Probe Number = 0, T = 22.562000 C 14:12:45 Temperature Measurement, Probe Number = 1, T = 30.601000 C 14:12:46 Temperature Measurement, Probe Number = 2, T = 19.275000 C 14:12:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317492 V 14:12:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317492 (V, A, ohm, ...), Measured Value = 28.298503 (C, atm, Hz, ...) 14:12:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.664900 V 14:12:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.664900 (V, A, ohm, ...), Measured Value = 33.123613 (C, atm, Hz, ...) 14:12:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665531 V 14:12:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665531 (V, A, ohm, ...), Measured Value = 124.914788 (C, atm, Hz, ...) 14:12:48 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106144 V 14:12:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106144 (V, A, ohm, ...), Measured Value = 7.960808 (C, atm, Hz, ...) 14:12:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.56 P3 = Coil, Value = 30.60 P4 = Ambient Temp (C), Value = 19.27 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.12 P7 = Supply Pres(psi), Value = 124.91 P8 = Return Pres(psi), Value = 7.96 14:13:49 Magnet Current for MAIN, Imag = 200.1383 A Vtrans = 2.001329 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:13:50 MAIN (V) Voltage Measurement, V = 31.678511 V 14:13:51 Temperature Measurement, Probe Number = 0, T = 22.590000 C 14:13:51 Temperature Measurement, Probe Number = 1, T = 30.622000 C 14:13:52 Temperature Measurement, Probe Number = 2, T = 19.305000 C 14:13:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317270 V 14:13:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317270 (V, A, ohm, ...), Measured Value = 28.295414 (C, atm, Hz, ...) 14:13:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.673837 V 14:13:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.673837 (V, A, ohm, ...), Measured Value = 33.247736 (C, atm, Hz, ...) 14:13:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.667910 V 14:13:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667910 (V, A, ohm, ...), Measured Value = 125.093250 (C, atm, Hz, ...) 14:13:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106211 V 14:13:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106211 (V, A, ohm, ...), Measured Value = 7.965862 (C, atm, Hz, ...) 14:13:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.59 P3 = Coil, Value = 30.62 P4 = Ambient Temp (C), Value = 19.30 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.25 P7 = Supply Pres(psi), Value = 125.09 P8 = Return Pres(psi), Value = 7.97 14:14:55 Magnet Current for MAIN, Imag = 200.1379 A Vtrans = 2.001325 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:14:56 MAIN (V) Voltage Measurement, V = 31.678881 V 14:14:57 Temperature Measurement, Probe Number = 0, T = 22.618000 C 14:14:57 Temperature Measurement, Probe Number = 1, T = 30.584000 C 14:14:58 Temperature Measurement, Probe Number = 2, T = 19.249000 C 14:14:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317351 V 14:14:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317351 (V, A, ohm, ...), Measured Value = 28.296543 (C, atm, Hz, ...) 14:14:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.680949 V 14:14:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.680949 (V, A, ohm, ...), Measured Value = 33.346508 (C, atm, Hz, ...) 14:15:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662226 V 14:15:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662226 (V, A, ohm, ...), Measured Value = 124.666927 (C, atm, Hz, ...) 14:15:00 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106102 V 14:15:00 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106102 (V, A, ohm, ...), Measured Value = 7.957665 (C, atm, Hz, ...) 14:15:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.62 P3 = Coil, Value = 30.58 P4 = Ambient Temp (C), Value = 19.25 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.35 P7 = Supply Pres(psi), Value = 124.67 P8 = Return Pres(psi), Value = 7.96 14:16:01 Magnet Current for MAIN, Imag = 200.1387 A Vtrans = 2.001332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:16:02 MAIN (V) Voltage Measurement, V = 31.679008 V 14:16:02 Temperature Measurement, Probe Number = 0, T = 22.640000 C 14:16:03 Temperature Measurement, Probe Number = 1, T = 30.670000 C 14:16:04 Temperature Measurement, Probe Number = 2, T = 19.300000 C 14:16:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317426 V 14:16:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317426 (V, A, ohm, ...), Measured Value = 28.297585 (C, atm, Hz, ...) 14:16:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.686825 V 14:16:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.686825 (V, A, ohm, ...), Measured Value = 33.428122 (C, atm, Hz, ...) 14:16:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658753 V 14:16:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658753 (V, A, ohm, ...), Measured Value = 124.406483 (C, atm, Hz, ...) 14:16:06 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106226 V 14:16:06 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106226 (V, A, ohm, ...), Measured Value = 7.966913 (C, atm, Hz, ...) 14:16:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.64 P3 = Coil, Value = 30.67 P4 = Ambient Temp (C), Value = 19.30 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.43 P7 = Supply Pres(psi), Value = 124.41 P8 = Return Pres(psi), Value = 7.97 14:17:07 Magnet Current for MAIN, Imag = 200.1386 A Vtrans = 2.001331 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:17:08 MAIN (V) Voltage Measurement, V = 31.679442 V 14:17:09 Temperature Measurement, Probe Number = 0, T = 22.662000 C 14:17:09 Temperature Measurement, Probe Number = 1, T = 30.697000 C 14:17:10 Temperature Measurement, Probe Number = 2, T = 19.371000 C 14:17:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317263 V 14:17:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317263 (V, A, ohm, ...), Measured Value = 28.295325 (C, atm, Hz, ...) 14:17:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.691511 V 14:17:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.691511 (V, A, ohm, ...), Measured Value = 33.493213 (C, atm, Hz, ...) 14:17:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660331 V 14:17:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660331 (V, A, ohm, ...), Measured Value = 124.524795 (C, atm, Hz, ...) 14:17:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106018 V 14:17:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106018 (V, A, ohm, ...), Measured Value = 7.951372 (C, atm, Hz, ...) 14:17:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.66 P3 = Coil, Value = 30.70 P4 = Ambient Temp (C), Value = 19.37 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.49 P7 = Supply Pres(psi), Value = 124.52 P8 = Return Pres(psi), Value = 7.95 14:18:13 Magnet Current for MAIN, Imag = 200.1389 A Vtrans = 2.001335 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:18:14 MAIN (V) Voltage Measurement, V = 31.679646 V 14:18:15 Temperature Measurement, Probe Number = 0, T = 22.689000 C 14:18:15 Temperature Measurement, Probe Number = 1, T = 30.714000 C 14:18:16 Temperature Measurement, Probe Number = 2, T = 19.393000 C 14:18:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317135 V 14:18:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317135 (V, A, ohm, ...), Measured Value = 28.293542 (C, atm, Hz, ...) 14:18:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.695647 V 14:18:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.695647 (V, A, ohm, ...), Measured Value = 33.550657 (C, atm, Hz, ...) 14:18:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664009 V 14:18:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664009 (V, A, ohm, ...), Measured Value = 124.800675 (C, atm, Hz, ...) 14:18:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106122 V 14:18:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106122 (V, A, ohm, ...), Measured Value = 7.959187 (C, atm, Hz, ...) 14:18:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.69 P3 = Coil, Value = 30.71 P4 = Ambient Temp (C), Value = 19.39 P5 = Supply Temp(C), Value = 28.29 P6 = Return Temp(C), Value = 33.55 P7 = Supply Pres(psi), Value = 124.80 P8 = Return Pres(psi), Value = 7.96 14:19:19 Magnet Current for MAIN, Imag = 200.1391 A Vtrans = 2.001336 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:19:20 MAIN (V) Voltage Measurement, V = 31.679902 V 14:19:21 Temperature Measurement, Probe Number = 0, T = 22.716000 C 14:19:21 Temperature Measurement, Probe Number = 1, T = 30.687000 C 14:19:22 Temperature Measurement, Probe Number = 2, T = 19.455000 C 14:19:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317340 V 14:19:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317340 (V, A, ohm, ...), Measured Value = 28.296385 (C, atm, Hz, ...) 14:19:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.699412 V 14:19:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.699412 (V, A, ohm, ...), Measured Value = 33.602947 (C, atm, Hz, ...) 14:19:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656539 V 14:19:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656539 (V, A, ohm, ...), Measured Value = 124.240418 (C, atm, Hz, ...) 14:19:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106367 V 14:19:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106367 (V, A, ohm, ...), Measured Value = 7.977495 (C, atm, Hz, ...) 14:19:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.72 P3 = Coil, Value = 30.69 P4 = Ambient Temp (C), Value = 19.45 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.60 P7 = Supply Pres(psi), Value = 124.24 P8 = Return Pres(psi), Value = 7.98 14:20:25 Magnet Current for MAIN, Imag = 200.1393 A Vtrans = 2.001339 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:20:26 MAIN (V) Voltage Measurement, V = 31.680412 V 14:20:27 Temperature Measurement, Probe Number = 0, T = 22.741000 C 14:20:27 Temperature Measurement, Probe Number = 1, T = 30.682000 C 14:20:28 Temperature Measurement, Probe Number = 2, T = 19.474000 C 14:20:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317560 V 14:20:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317560 (V, A, ohm, ...), Measured Value = 28.299439 (C, atm, Hz, ...) 14:20:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.702983 V 14:20:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.702983 (V, A, ohm, ...), Measured Value = 33.652538 (C, atm, Hz, ...) 14:20:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657547 V 14:20:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657547 (V, A, ohm, ...), Measured Value = 124.316017 (C, atm, Hz, ...) 14:20:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106600 V 14:20:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106600 (V, A, ohm, ...), Measured Value = 7.995030 (C, atm, Hz, ...) 14:20:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.74 P3 = Coil, Value = 30.68 P4 = Ambient Temp (C), Value = 19.47 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.65 P7 = Supply Pres(psi), Value = 124.32 P8 = Return Pres(psi), Value = 8.00 14:21:31 Magnet Current for MAIN, Imag = 200.1392 A Vtrans = 2.001337 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:21:32 MAIN (V) Voltage Measurement, V = 31.680693 V 14:21:33 Temperature Measurement, Probe Number = 0, T = 22.763000 C 14:21:33 Temperature Measurement, Probe Number = 1, T = 30.702000 C 14:21:34 Temperature Measurement, Probe Number = 2, T = 19.490000 C 14:21:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317584 V 14:21:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317584 (V, A, ohm, ...), Measured Value = 28.299774 (C, atm, Hz, ...) 14:21:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.705855 V 14:21:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.705855 (V, A, ohm, ...), Measured Value = 33.692435 (C, atm, Hz, ...) 14:21:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656694 V 14:21:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656694 (V, A, ohm, ...), Measured Value = 124.252050 (C, atm, Hz, ...) 14:21:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106668 V 14:21:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106668 (V, A, ohm, ...), Measured Value = 8.000085 (C, atm, Hz, ...) 14:21:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.76 P3 = Coil, Value = 30.70 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.69 P7 = Supply Pres(psi), Value = 124.25 P8 = Return Pres(psi), Value = 8.00 14:22:37 Magnet Current for MAIN, Imag = 200.1391 A Vtrans = 2.001336 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:22:38 MAIN (V) Voltage Measurement, V = 31.680986 V 14:22:39 Temperature Measurement, Probe Number = 0, T = 22.786000 C 14:22:39 Temperature Measurement, Probe Number = 1, T = 30.718000 C 14:22:40 Temperature Measurement, Probe Number = 2, T = 19.495000 C 14:22:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317465 V 14:22:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317465 (V, A, ohm, ...), Measured Value = 28.298132 (C, atm, Hz, ...) 14:22:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.708375 V 14:22:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.708375 (V, A, ohm, ...), Measured Value = 33.727425 (C, atm, Hz, ...) 14:22:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658987 V 14:22:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658987 (V, A, ohm, ...), Measured Value = 124.424025 (C, atm, Hz, ...) 14:22:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106223 V 14:22:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106223 (V, A, ohm, ...), Measured Value = 7.966717 (C, atm, Hz, ...) 14:22:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.79 P3 = Coil, Value = 30.72 P4 = Ambient Temp (C), Value = 19.50 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.73 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 7.97 14:23:43 Magnet Current for MAIN, Imag = 200.1401 A Vtrans = 2.001346 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:23:44 MAIN (V) Voltage Measurement, V = 31.681344 V 14:23:45 Temperature Measurement, Probe Number = 0, T = 22.810000 C 14:23:45 Temperature Measurement, Probe Number = 1, T = 30.734000 C 14:23:46 Temperature Measurement, Probe Number = 2, T = 19.516000 C 14:23:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317788 V 14:23:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317788 (V, A, ohm, ...), Measured Value = 28.302617 (C, atm, Hz, ...) 14:23:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.710195 V 14:23:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.710195 (V, A, ohm, ...), Measured Value = 33.752706 (C, atm, Hz, ...) 14:23:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659685 V 14:23:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659685 (V, A, ohm, ...), Measured Value = 124.476360 (C, atm, Hz, ...) 14:23:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106245 V 14:23:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106245 (V, A, ohm, ...), Measured Value = 7.968338 (C, atm, Hz, ...) 14:23:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.81 P3 = Coil, Value = 30.73 P4 = Ambient Temp (C), Value = 19.52 P5 = Supply Temp(C), Value = 28.30 P6 = Return Temp(C), Value = 33.75 P7 = Supply Pres(psi), Value = 124.48 P8 = Return Pres(psi), Value = 7.97 14:24:49 Magnet Current for MAIN, Imag = 200.1398 A Vtrans = 2.001344 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:24:50 MAIN (V) Voltage Measurement, V = 31.681841 V 14:24:51 Temperature Measurement, Probe Number = 0, T = 22.830000 C 14:24:51 Temperature Measurement, Probe Number = 1, T = 30.718000 C 14:24:52 Temperature Measurement, Probe Number = 2, T = 19.524000 C 14:24:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318270 V 14:24:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318270 (V, A, ohm, ...), Measured Value = 28.309307 (C, atm, Hz, ...) 14:24:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.712024 V 14:24:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.712024 (V, A, ohm, ...), Measured Value = 33.778108 (C, atm, Hz, ...) 14:24:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.653792 V 14:24:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653792 (V, A, ohm, ...), Measured Value = 124.034408 (C, atm, Hz, ...) 14:24:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106353 V 14:24:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106353 (V, A, ohm, ...), Measured Value = 7.976445 (C, atm, Hz, ...) 14:24:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.83 P3 = Coil, Value = 30.72 P4 = Ambient Temp (C), Value = 19.52 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.78 P7 = Supply Pres(psi), Value = 124.03 P8 = Return Pres(psi), Value = 7.98 14:25:56 Magnet Current for MAIN, Imag = 200.1401 A Vtrans = 2.001346 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:25:56 MAIN (V) Voltage Measurement, V = 31.682262 V 14:25:57 Temperature Measurement, Probe Number = 0, T = 22.848000 C 14:25:57 Temperature Measurement, Probe Number = 1, T = 30.744000 C 14:25:58 Temperature Measurement, Probe Number = 2, T = 19.502000 C 14:25:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318223 V 14:25:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318223 (V, A, ohm, ...), Measured Value = 28.308654 (C, atm, Hz, ...) 14:25:59 Sensor Voltage Measurement, Sensor Number = 1, V = 2.713839 V 14:25:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.713839 (V, A, ohm, ...), Measured Value = 33.803318 (C, atm, Hz, ...) 14:26:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657827 V 14:26:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657827 (V, A, ohm, ...), Measured Value = 124.336988 (C, atm, Hz, ...) 14:26:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106491 V 14:26:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106491 (V, A, ohm, ...), Measured Value = 7.986832 (C, atm, Hz, ...) 14:26:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.85 P3 = Coil, Value = 30.74 P4 = Ambient Temp (C), Value = 19.50 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.80 P7 = Supply Pres(psi), Value = 124.34 P8 = Return Pres(psi), Value = 7.99 14:27:02 Magnet Current for MAIN, Imag = 200.1403 A Vtrans = 2.001349 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:27:02 MAIN (V) Voltage Measurement, V = 31.682479 V 14:27:03 Temperature Measurement, Probe Number = 0, T = 22.874000 C 14:27:03 Temperature Measurement, Probe Number = 1, T = 30.771000 C 14:27:04 Temperature Measurement, Probe Number = 2, T = 19.492000 C 14:27:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318363 V 14:27:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318363 (V, A, ohm, ...), Measured Value = 28.310596 (C, atm, Hz, ...) 14:27:05 Sensor Voltage Measurement, Sensor Number = 1, V = 2.715566 V 14:27:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.715566 (V, A, ohm, ...), Measured Value = 33.827310 (C, atm, Hz, ...) 14:27:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652202 V 14:27:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652202 (V, A, ohm, ...), Measured Value = 123.915150 (C, atm, Hz, ...) 14:27:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106584 V 14:27:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106584 (V, A, ohm, ...), Measured Value = 7.993792 (C, atm, Hz, ...) 14:27:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.87 P3 = Coil, Value = 30.77 P4 = Ambient Temp (C), Value = 19.49 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.83 P7 = Supply Pres(psi), Value = 123.92 P8 = Return Pres(psi), Value = 7.99 14:28:07 Magnet Current for MAIN, Imag = 200.1400 A Vtrans = 2.001345 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:28:08 MAIN (V) Voltage Measurement, V = 31.682785 V 14:28:09 Temperature Measurement, Probe Number = 0, T = 22.899000 C 14:28:09 Temperature Measurement, Probe Number = 1, T = 30.762000 C 14:28:10 Temperature Measurement, Probe Number = 2, T = 19.519000 C 14:28:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318982 V 14:28:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318982 (V, A, ohm, ...), Measured Value = 28.319193 (C, atm, Hz, ...) 14:28:11 Sensor Voltage Measurement, Sensor Number = 1, V = 2.717561 V 14:28:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.717561 (V, A, ohm, ...), Measured Value = 33.855008 (C, atm, Hz, ...) 14:28:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664801 V 14:28:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664801 (V, A, ohm, ...), Measured Value = 124.860067 (C, atm, Hz, ...) 14:28:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106680 V 14:28:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106680 (V, A, ohm, ...), Measured Value = 8.001037 (C, atm, Hz, ...) 14:28:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.90 P3 = Coil, Value = 30.76 P4 = Ambient Temp (C), Value = 19.52 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.86 P7 = Supply Pres(psi), Value = 124.86 P8 = Return Pres(psi), Value = 8.00 14:29:13 Magnet Current for MAIN, Imag = 200.1401 A Vtrans = 2.001346 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:29:14 MAIN (V) Voltage Measurement, V = 31.683041 V 14:29:15 Temperature Measurement, Probe Number = 0, T = 22.921000 C 14:29:15 Temperature Measurement, Probe Number = 1, T = 30.744000 C 14:29:16 Temperature Measurement, Probe Number = 2, T = 19.561000 C 14:29:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318836 V 14:29:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318836 (V, A, ohm, ...), Measured Value = 28.317163 (C, atm, Hz, ...) 14:29:17 Sensor Voltage Measurement, Sensor Number = 1, V = 2.719729 V 14:29:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.719729 (V, A, ohm, ...), Measured Value = 33.885126 (C, atm, Hz, ...) 14:29:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661073 V 14:29:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661073 (V, A, ohm, ...), Measured Value = 124.580468 (C, atm, Hz, ...) 14:29:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106845 V 14:29:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106845 (V, A, ohm, ...), Measured Value = 8.013338 (C, atm, Hz, ...) 14:29:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.92 P3 = Coil, Value = 30.74 P4 = Ambient Temp (C), Value = 19.56 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.89 P7 = Supply Pres(psi), Value = 124.58 P8 = Return Pres(psi), Value = 8.01 14:30:19 Magnet Current for MAIN, Imag = 200.1402 A Vtrans = 2.001348 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:30:20 MAIN (V) Voltage Measurement, V = 31.683143 V 14:30:21 Temperature Measurement, Probe Number = 0, T = 22.941000 C 14:30:21 Temperature Measurement, Probe Number = 1, T = 30.751000 C 14:30:22 Temperature Measurement, Probe Number = 2, T = 19.577000 C 14:30:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318616 V 14:30:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318616 (V, A, ohm, ...), Measured Value = 28.314108 (C, atm, Hz, ...) 14:30:23 Sensor Voltage Measurement, Sensor Number = 1, V = 2.721543 V 14:30:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.721543 (V, A, ohm, ...), Measured Value = 33.910318 (C, atm, Hz, ...) 14:30:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.649263 V 14:30:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649263 (V, A, ohm, ...), Measured Value = 123.694747 (C, atm, Hz, ...) 14:30:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106612 V 14:30:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106612 (V, A, ohm, ...), Measured Value = 7.995893 (C, atm, Hz, ...) 14:30:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.94 P3 = Coil, Value = 30.75 P4 = Ambient Temp (C), Value = 19.58 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.91 P7 = Supply Pres(psi), Value = 123.69 P8 = Return Pres(psi), Value = 8.00 14:31:25 Magnet Current for MAIN, Imag = 200.1405 A Vtrans = 2.001350 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:31:26 MAIN (V) Voltage Measurement, V = 31.683066 V 14:31:27 Temperature Measurement, Probe Number = 0, T = 22.963000 C 14:31:27 Temperature Measurement, Probe Number = 1, T = 30.756000 C 14:31:28 Temperature Measurement, Probe Number = 2, T = 19.621000 C 14:31:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318204 V 14:31:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318204 (V, A, ohm, ...), Measured Value = 28.308389 (C, atm, Hz, ...) 14:31:29 Sensor Voltage Measurement, Sensor Number = 1, V = 2.722777 V 14:31:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.722777 (V, A, ohm, ...), Measured Value = 33.927460 (C, atm, Hz, ...) 14:31:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654484 V 14:31:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654484 (V, A, ohm, ...), Measured Value = 124.086270 (C, atm, Hz, ...) 14:31:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106279 V 14:31:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106279 (V, A, ohm, ...), Measured Value = 7.970917 (C, atm, Hz, ...) 14:31:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.96 P3 = Coil, Value = 30.76 P4 = Ambient Temp (C), Value = 19.62 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.93 P7 = Supply Pres(psi), Value = 124.09 P8 = Return Pres(psi), Value = 7.97 14:32:31 Magnet Current for MAIN, Imag = 200.1403 A Vtrans = 2.001349 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:32:32 MAIN (V) Voltage Measurement, V = 31.682964 V 14:32:33 Temperature Measurement, Probe Number = 0, T = 22.991000 C 14:32:33 Temperature Measurement, Probe Number = 1, T = 30.745000 C 14:32:34 Temperature Measurement, Probe Number = 2, T = 19.604000 C 14:32:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318236 V 14:32:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318236 (V, A, ohm, ...), Measured Value = 28.308831 (C, atm, Hz, ...) 14:32:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.723809 V 14:32:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.723809 (V, A, ohm, ...), Measured Value = 33.941794 (C, atm, Hz, ...) 14:32:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.649707 V 14:32:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649707 (V, A, ohm, ...), Measured Value = 123.728017 (C, atm, Hz, ...) 14:32:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106112 V 14:32:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106112 (V, A, ohm, ...), Measured Value = 7.958422 (C, atm, Hz, ...) 14:32:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 22.99 P3 = Coil, Value = 30.75 P4 = Ambient Temp (C), Value = 19.60 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.94 P7 = Supply Pres(psi), Value = 123.73 P8 = Return Pres(psi), Value = 7.96 14:33:38 Magnet Current for MAIN, Imag = 200.1409 A Vtrans = 2.001354 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:33:38 MAIN (V) Voltage Measurement, V = 31.683181 V 14:33:39 Temperature Measurement, Probe Number = 0, T = 23.015000 C 14:33:39 Temperature Measurement, Probe Number = 1, T = 30.747000 C 14:33:40 Temperature Measurement, Probe Number = 2, T = 19.632000 C 14:33:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318582 V 14:33:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318582 (V, A, ohm, ...), Measured Value = 28.313632 (C, atm, Hz, ...) 14:33:41 Sensor Voltage Measurement, Sensor Number = 1, V = 2.724521 V 14:33:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.724521 (V, A, ohm, ...), Measured Value = 33.951681 (C, atm, Hz, ...) 14:33:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658987 V 14:33:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658987 (V, A, ohm, ...), Measured Value = 124.424025 (C, atm, Hz, ...) 14:33:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106516 V 14:33:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106516 (V, A, ohm, ...), Measured Value = 7.988737 (C, atm, Hz, ...) 14:33:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.02 P3 = Coil, Value = 30.75 P4 = Ambient Temp (C), Value = 19.63 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.95 P7 = Supply Pres(psi), Value = 124.42 P8 = Return Pres(psi), Value = 7.99 14:34:44 Magnet Current for MAIN, Imag = 200.1407 A Vtrans = 2.001353 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:34:44 MAIN (V) Voltage Measurement, V = 31.683487 V 14:34:45 Temperature Measurement, Probe Number = 0, T = 23.040000 C 14:34:46 Temperature Measurement, Probe Number = 1, T = 30.756000 C 14:34:46 Temperature Measurement, Probe Number = 2, T = 19.708000 C 14:34:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318261 V 14:34:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318261 (V, A, ohm, ...), Measured Value = 28.309183 (C, atm, Hz, ...) 14:34:47 Sensor Voltage Measurement, Sensor Number = 1, V = 2.725243 V 14:34:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.725243 (V, A, ohm, ...), Measured Value = 33.961708 (C, atm, Hz, ...) 14:34:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660277 V 14:34:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660277 (V, A, ohm, ...), Measured Value = 124.520790 (C, atm, Hz, ...) 14:34:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106552 V 14:34:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106552 (V, A, ohm, ...), Measured Value = 7.991408 (C, atm, Hz, ...) 14:34:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.04 P3 = Coil, Value = 30.76 P4 = Ambient Temp (C), Value = 19.71 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.96 P7 = Supply Pres(psi), Value = 124.52 P8 = Return Pres(psi), Value = 7.99 14:35:50 Magnet Current for MAIN, Imag = 200.1406 A Vtrans = 2.001352 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:35:50 MAIN (V) Voltage Measurement, V = 31.683526 V 14:35:51 Temperature Measurement, Probe Number = 0, T = 23.064000 C 14:35:52 Temperature Measurement, Probe Number = 1, T = 30.773000 C 14:35:52 Temperature Measurement, Probe Number = 2, T = 19.804000 C 14:35:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318424 V 14:35:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318424 (V, A, ohm, ...), Measured Value = 28.311443 (C, atm, Hz, ...) 14:35:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.725904 V 14:35:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.725904 (V, A, ohm, ...), Measured Value = 33.970889 (C, atm, Hz, ...) 14:35:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.670203 V 14:35:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670203 (V, A, ohm, ...), Measured Value = 125.265225 (C, atm, Hz, ...) 14:35:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106672 V 14:35:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106672 (V, A, ohm, ...), Measured Value = 8.000370 (C, atm, Hz, ...) 14:35:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.06 P3 = Coil, Value = 30.77 P4 = Ambient Temp (C), Value = 19.80 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.97 P7 = Supply Pres(psi), Value = 125.27 P8 = Return Pres(psi), Value = 8.00 14:36:56 Magnet Current for MAIN, Imag = 200.1407 A Vtrans = 2.001353 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:36:56 MAIN (V) Voltage Measurement, V = 31.683883 V 14:36:57 Temperature Measurement, Probe Number = 0, T = 23.086000 C 14:36:58 Temperature Measurement, Probe Number = 1, T = 30.787000 C 14:36:58 Temperature Measurement, Probe Number = 2, T = 19.748000 C 14:36:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318846 V 14:36:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318846 (V, A, ohm, ...), Measured Value = 28.317304 (C, atm, Hz, ...) 14:37:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726135 V 14:37:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726135 (V, A, ohm, ...), Measured Value = 33.974101 (C, atm, Hz, ...) 14:37:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.659270 V 14:37:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659270 (V, A, ohm, ...), Measured Value = 124.445287 (C, atm, Hz, ...) 14:37:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106339 V 14:37:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106339 (V, A, ohm, ...), Measured Value = 7.975395 (C, atm, Hz, ...) 14:37:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.09 P3 = Coil, Value = 30.79 P4 = Ambient Temp (C), Value = 19.75 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.97 P7 = Supply Pres(psi), Value = 124.45 P8 = Return Pres(psi), Value = 7.98 14:38:02 Magnet Current for MAIN, Imag = 200.1411 A Vtrans = 2.001356 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:38:02 MAIN (V) Voltage Measurement, V = 31.683883 V 14:38:03 Temperature Measurement, Probe Number = 0, T = 23.110000 C 14:38:04 Temperature Measurement, Probe Number = 1, T = 30.757000 C 14:38:04 Temperature Measurement, Probe Number = 2, T = 19.760000 C 14:38:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318691 V 14:38:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318691 (V, A, ohm, ...), Measured Value = 28.315150 (C, atm, Hz, ...) 14:38:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726381 V 14:38:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726381 (V, A, ohm, ...), Measured Value = 33.977514 (C, atm, Hz, ...) 14:38:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660683 V 14:38:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660683 (V, A, ohm, ...), Measured Value = 124.551195 (C, atm, Hz, ...) 14:38:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106653 V 14:38:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106653 (V, A, ohm, ...), Measured Value = 7.998945 (C, atm, Hz, ...) 14:38:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.11 P3 = Coil, Value = 30.76 P4 = Ambient Temp (C), Value = 19.76 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.98 P7 = Supply Pres(psi), Value = 124.55 P8 = Return Pres(psi), Value = 8.00 14:39:08 Magnet Current for MAIN, Imag = 200.1410 A Vtrans = 2.001355 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:39:08 MAIN (V) Voltage Measurement, V = 31.684355 V 14:39:09 Temperature Measurement, Probe Number = 0, T = 23.125000 C 14:39:10 Temperature Measurement, Probe Number = 1, T = 30.739000 C 14:39:10 Temperature Measurement, Probe Number = 2, T = 19.668000 C 14:39:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319048 V 14:39:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319048 (V, A, ohm, ...), Measured Value = 28.320111 (C, atm, Hz, ...) 14:39:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726182 V 14:39:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726182 (V, A, ohm, ...), Measured Value = 33.974754 (C, atm, Hz, ...) 14:39:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.648122 V 14:39:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648122 (V, A, ohm, ...), Measured Value = 123.609143 (C, atm, Hz, ...) 14:39:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106680 V 14:39:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106680 (V, A, ohm, ...), Measured Value = 8.001037 (C, atm, Hz, ...) 14:39:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.12 P3 = Coil, Value = 30.74 P4 = Ambient Temp (C), Value = 19.67 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.97 P7 = Supply Pres(psi), Value = 123.61 P8 = Return Pres(psi), Value = 8.00 14:40:14 Magnet Current for MAIN, Imag = 200.1410 A Vtrans = 2.001355 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:40:14 MAIN (V) Voltage Measurement, V = 31.684329 V 14:40:15 Temperature Measurement, Probe Number = 0, T = 23.143000 C 14:40:16 Temperature Measurement, Probe Number = 1, T = 30.734000 C 14:40:16 Temperature Measurement, Probe Number = 2, T = 19.618000 C 14:40:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318571 V 14:40:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318571 (V, A, ohm, ...), Measured Value = 28.313490 (C, atm, Hz, ...) 14:40:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726149 V 14:40:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726149 (V, A, ohm, ...), Measured Value = 33.974296 (C, atm, Hz, ...) 14:40:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658162 V 14:40:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658162 (V, A, ohm, ...), Measured Value = 124.362158 (C, atm, Hz, ...) 14:40:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106508 V 14:40:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106508 (V, A, ohm, ...), Measured Value = 7.988078 (C, atm, Hz, ...) 14:40:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.14 P3 = Coil, Value = 30.73 P4 = Ambient Temp (C), Value = 19.62 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 33.97 P7 = Supply Pres(psi), Value = 124.36 P8 = Return Pres(psi), Value = 7.99 14:41:20 Magnet Current for MAIN, Imag = 200.1407 A Vtrans = 2.001353 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:41:20 MAIN (V) Voltage Measurement, V = 31.684227 V 14:41:21 Temperature Measurement, Probe Number = 0, T = 23.163000 C 14:41:22 Temperature Measurement, Probe Number = 1, T = 30.778000 C 14:41:22 Temperature Measurement, Probe Number = 2, T = 19.628000 C 14:41:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318768 V 14:41:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318768 (V, A, ohm, ...), Measured Value = 28.316226 (C, atm, Hz, ...) 14:41:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.726615 V 14:41:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.726615 (V, A, ohm, ...), Measured Value = 33.980762 (C, atm, Hz, ...) 14:41:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658129 V 14:41:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658129 (V, A, ohm, ...), Measured Value = 124.359683 (C, atm, Hz, ...) 14:41:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106356 V 14:41:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106356 (V, A, ohm, ...), Measured Value = 7.976730 (C, atm, Hz, ...) 14:41:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.16 P3 = Coil, Value = 30.78 P4 = Ambient Temp (C), Value = 19.63 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.98 P7 = Supply Pres(psi), Value = 124.36 P8 = Return Pres(psi), Value = 7.98 14:42:26 Magnet Current for MAIN, Imag = 200.1411 A Vtrans = 2.001356 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:42:26 MAIN (V) Voltage Measurement, V = 31.684125 V 14:42:27 Temperature Measurement, Probe Number = 0, T = 23.187000 C 14:42:28 Temperature Measurement, Probe Number = 1, T = 30.774000 C 14:42:28 Temperature Measurement, Probe Number = 2, T = 19.598000 C 14:42:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318855 V 14:42:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318855 (V, A, ohm, ...), Measured Value = 28.317428 (C, atm, Hz, ...) 14:42:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.727483 V 14:42:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.727483 (V, A, ohm, ...), Measured Value = 33.992819 (C, atm, Hz, ...) 14:42:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664791 V 14:42:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664791 (V, A, ohm, ...), Measured Value = 124.859303 (C, atm, Hz, ...) 14:42:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106691 V 14:42:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106691 (V, A, ohm, ...), Measured Value = 8.001802 (C, atm, Hz, ...) 14:42:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.19 P3 = Coil, Value = 30.77 P4 = Ambient Temp (C), Value = 19.60 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 33.99 P7 = Supply Pres(psi), Value = 124.86 P8 = Return Pres(psi), Value = 8.00 14:43:32 Magnet Current for MAIN, Imag = 200.1410 A Vtrans = 2.001355 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:43:32 MAIN (V) Voltage Measurement, V = 31.683947 V 14:43:33 Temperature Measurement, Probe Number = 0, T = 23.211000 C 14:43:34 Temperature Measurement, Probe Number = 1, T = 30.784000 C 14:43:34 Temperature Measurement, Probe Number = 2, T = 19.643000 C 14:43:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318976 V 14:43:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318976 (V, A, ohm, ...), Measured Value = 28.319104 (C, atm, Hz, ...) 14:43:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.729191 V 14:43:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.729191 (V, A, ohm, ...), Measured Value = 34.016547 (C, atm, Hz, ...) 14:43:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.650837 V 14:43:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650837 (V, A, ohm, ...), Measured Value = 123.812767 (C, atm, Hz, ...) 14:43:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106702 V 14:43:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106702 (V, A, ohm, ...), Measured Value = 8.002657 (C, atm, Hz, ...) 14:43:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.21 P3 = Coil, Value = 30.78 P4 = Ambient Temp (C), Value = 19.64 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 34.02 P7 = Supply Pres(psi), Value = 123.81 P8 = Return Pres(psi), Value = 8.00 14:44:38 Magnet Current for MAIN, Imag = 200.1416 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:44:38 MAIN (V) Voltage Measurement, V = 31.684049 V 14:44:39 Temperature Measurement, Probe Number = 0, T = 23.233000 C 14:44:40 Temperature Measurement, Probe Number = 1, T = 30.779000 C 14:44:40 Temperature Measurement, Probe Number = 2, T = 19.710000 C 14:44:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318963 V 14:44:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318963 (V, A, ohm, ...), Measured Value = 28.318928 (C, atm, Hz, ...) 14:44:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.730882 V 14:44:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.730882 (V, A, ohm, ...), Measured Value = 34.040026 (C, atm, Hz, ...) 14:44:42 Sensor Voltage Measurement, Sensor Number = 2, V = 2.673297 V 14:44:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.673297 (V, A, ohm, ...), Measured Value = 125.497260 (C, atm, Hz, ...) 14:44:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106632 V 14:44:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106632 (V, A, ohm, ...), Measured Value = 7.997415 (C, atm, Hz, ...) 14:44:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.23 P3 = Coil, Value = 30.78 P4 = Ambient Temp (C), Value = 19.71 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 34.04 P7 = Supply Pres(psi), Value = 125.50 P8 = Return Pres(psi), Value = 8.00 14:45:44 Magnet Current for MAIN, Imag = 200.1416 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:45:44 MAIN (V) Voltage Measurement, V = 31.684061 V 14:45:45 Temperature Measurement, Probe Number = 0, T = 23.257000 C 14:45:46 Temperature Measurement, Probe Number = 1, T = 30.781000 C 14:45:46 Temperature Measurement, Probe Number = 2, T = 19.738000 C 14:45:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318900 V 14:45:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318900 (V, A, ohm, ...), Measured Value = 28.318062 (C, atm, Hz, ...) 14:45:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732142 V 14:45:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732142 (V, A, ohm, ...), Measured Value = 34.057521 (C, atm, Hz, ...) 14:45:48 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651704 V 14:45:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651704 (V, A, ohm, ...), Measured Value = 123.877785 (C, atm, Hz, ...) 14:45:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106860 V 14:45:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106860 (V, A, ohm, ...), Measured Value = 8.014477 (C, atm, Hz, ...) 14:45:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.26 P3 = Coil, Value = 30.78 P4 = Ambient Temp (C), Value = 19.74 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 34.06 P7 = Supply Pres(psi), Value = 123.88 P8 = Return Pres(psi), Value = 8.01 14:46:50 Magnet Current for MAIN, Imag = 200.1416 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:46:50 MAIN (V) Voltage Measurement, V = 31.683998 V 14:46:51 Temperature Measurement, Probe Number = 0, T = 23.280000 C 14:46:52 Temperature Measurement, Probe Number = 1, T = 30.731000 C 14:46:52 Temperature Measurement, Probe Number = 2, T = 19.735000 C 14:46:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318447 V 14:46:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318447 (V, A, ohm, ...), Measured Value = 28.311761 (C, atm, Hz, ...) 14:46:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732822 V 14:46:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732822 (V, A, ohm, ...), Measured Value = 34.066965 (C, atm, Hz, ...) 14:46:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664361 V 14:46:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664361 (V, A, ohm, ...), Measured Value = 124.827082 (C, atm, Hz, ...) 14:46:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106768 V 14:46:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106768 (V, A, ohm, ...), Measured Value = 8.007615 (C, atm, Hz, ...) 14:46:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.28 P3 = Coil, Value = 30.73 P4 = Ambient Temp (C), Value = 19.73 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 34.07 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 8.01 14:47:56 Magnet Current for MAIN, Imag = 200.1416 A Vtrans = 2.001362 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:47:56 MAIN (V) Voltage Measurement, V = 31.683602 V 14:47:57 Temperature Measurement, Probe Number = 0, T = 23.297000 C 14:47:58 Temperature Measurement, Probe Number = 1, T = 30.752000 C 14:47:58 Temperature Measurement, Probe Number = 2, T = 19.788000 C 14:47:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.317973 V 14:47:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.317973 (V, A, ohm, ...), Measured Value = 28.305176 (C, atm, Hz, ...) 14:48:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732841 V 14:48:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732841 (V, A, ohm, ...), Measured Value = 34.067231 (C, atm, Hz, ...) 14:48:00 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665594 V 14:48:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665594 (V, A, ohm, ...), Measured Value = 124.919557 (C, atm, Hz, ...) 14:48:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106753 V 14:48:01 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106753 (V, A, ohm, ...), Measured Value = 8.006475 (C, atm, Hz, ...) 14:48:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.30 P3 = Coil, Value = 30.75 P4 = Ambient Temp (C), Value = 19.79 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 34.07 P7 = Supply Pres(psi), Value = 124.92 P8 = Return Pres(psi), Value = 8.01 14:49:02 Magnet Current for MAIN, Imag = 200.1419 A Vtrans = 2.001364 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:49:02 MAIN (V) Voltage Measurement, V = 31.683423 V 14:49:03 Temperature Measurement, Probe Number = 0, T = 23.324000 C 14:49:04 Temperature Measurement, Probe Number = 1, T = 30.780000 C 14:49:04 Temperature Measurement, Probe Number = 2, T = 19.735000 C 14:49:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318110 V 14:49:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318110 (V, A, ohm, ...), Measured Value = 28.307082 (C, atm, Hz, ...) 14:49:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.732979 V 14:49:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.732979 (V, A, ohm, ...), Measured Value = 34.069156 (C, atm, Hz, ...) 14:49:06 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656683 V 14:49:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656683 (V, A, ohm, ...), Measured Value = 124.251195 (C, atm, Hz, ...) 14:49:07 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106723 V 14:49:07 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106723 (V, A, ohm, ...), Measured Value = 8.004188 (C, atm, Hz, ...) 14:49:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.32 P3 = Coil, Value = 30.78 P4 = Ambient Temp (C), Value = 19.73 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 34.07 P7 = Supply Pres(psi), Value = 124.25 P8 = Return Pres(psi), Value = 8.00 14:50:08 Magnet Current for MAIN, Imag = 200.1419 A Vtrans = 2.001364 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:50:08 MAIN (V) Voltage Measurement, V = 31.683436 V 14:50:09 Temperature Measurement, Probe Number = 0, T = 23.342000 C 14:50:10 Temperature Measurement, Probe Number = 1, T = 30.796000 C 14:50:10 Temperature Measurement, Probe Number = 2, T = 19.721000 C 14:50:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.318565 V 14:50:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.318565 (V, A, ohm, ...), Measured Value = 28.313403 (C, atm, Hz, ...) 14:50:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.733613 V 14:50:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.733613 (V, A, ohm, ...), Measured Value = 34.077964 (C, atm, Hz, ...) 14:50:12 Sensor Voltage Measurement, Sensor Number = 2, V = 2.661270 V 14:50:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.661270 (V, A, ohm, ...), Measured Value = 124.595243 (C, atm, Hz, ...) 14:50:13 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106862 V 14:50:13 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106862 (V, A, ohm, ...), Measured Value = 8.014672 (C, atm, Hz, ...) 14:50:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.34 P3 = Coil, Value = 30.80 P4 = Ambient Temp (C), Value = 19.72 P5 = Supply Temp(C), Value = 28.31 P6 = Return Temp(C), Value = 34.08 P7 = Supply Pres(psi), Value = 124.60 P8 = Return Pres(psi), Value = 8.01 14:51:14 Magnet Current for MAIN, Imag = 200.1419 A Vtrans = 2.001364 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:51:14 MAIN (V) Voltage Measurement, V = 31.683793 V 14:51:15 Temperature Measurement, Probe Number = 0, T = 23.368000 C 14:51:16 Temperature Measurement, Probe Number = 1, T = 30.822000 C 14:51:16 Temperature Measurement, Probe Number = 2, T = 19.839000 C 14:51:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.319009 V 14:51:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.319009 (V, A, ohm, ...), Measured Value = 28.319564 (C, atm, Hz, ...) 14:51:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.734539 V 14:51:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.734539 (V, A, ohm, ...), Measured Value = 34.090817 (C, atm, Hz, ...) 14:51:18 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658139 V 14:51:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658139 (V, A, ohm, ...), Measured Value = 124.360440 (C, atm, Hz, ...) 14:51:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106761 V 14:51:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106761 (V, A, ohm, ...), Measured Value = 8.007045 (C, atm, Hz, ...) 14:51:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.37 P3 = Coil, Value = 30.82 P4 = Ambient Temp (C), Value = 19.84 P5 = Supply Temp(C), Value = 28.32 P6 = Return Temp(C), Value = 34.09 P7 = Supply Pres(psi), Value = 124.36 P8 = Return Pres(psi), Value = 8.01 14:52:20 Magnet Current for MAIN, Imag = 200.1421 A Vtrans = 2.001367 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:52:20 MAIN (V) Voltage Measurement, V = 31.684699 V 14:52:21 Temperature Measurement, Probe Number = 0, T = 23.393000 C 14:52:22 Temperature Measurement, Probe Number = 1, T = 30.825000 C 14:52:22 Temperature Measurement, Probe Number = 2, T = 19.810000 C 14:52:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320130 V 14:52:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320130 (V, A, ohm, ...), Measured Value = 28.335135 (C, atm, Hz, ...) 14:52:24 Sensor Voltage Measurement, Sensor Number = 1, V = 2.736058 V 14:52:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.736058 (V, A, ohm, ...), Measured Value = 34.111913 (C, atm, Hz, ...) 14:52:24 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662954 V 14:52:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662954 (V, A, ohm, ...), Measured Value = 124.721550 (C, atm, Hz, ...) 14:52:25 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106730 V 14:52:25 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106730 (V, A, ohm, ...), Measured Value = 8.004758 (C, atm, Hz, ...) 14:52:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.68 P2 = Magnet Core, Value = 23.39 P3 = Coil, Value = 30.82 P4 = Ambient Temp (C), Value = 19.81 P5 = Supply Temp(C), Value = 28.34 P6 = Return Temp(C), Value = 34.11 P7 = Supply Pres(psi), Value = 124.72 P8 = Return Pres(psi), Value = 8.00 14:53:26 Magnet Current for MAIN, Imag = 200.1426 A Vtrans = 2.001372 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:53:26 MAIN (V) Voltage Measurement, V = 31.685810 V 14:53:27 Temperature Measurement, Probe Number = 0, T = 23.415000 C 14:53:28 Temperature Measurement, Probe Number = 1, T = 30.818000 C 14:53:28 Temperature Measurement, Probe Number = 2, T = 19.843000 C 14:53:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.320919 V 14:53:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.320919 (V, A, ohm, ...), Measured Value = 28.346097 (C, atm, Hz, ...) 14:53:30 Sensor Voltage Measurement, Sensor Number = 1, V = 2.737737 V 14:53:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.737737 (V, A, ohm, ...), Measured Value = 34.135233 (C, atm, Hz, ...) 14:53:30 Sensor Voltage Measurement, Sensor Number = 2, V = 2.650669 V 14:53:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650669 (V, A, ohm, ...), Measured Value = 123.800183 (C, atm, Hz, ...) 14:53:31 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106778 V 14:53:31 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106778 (V, A, ohm, ...), Measured Value = 8.008380 (C, atm, Hz, ...) 14:53:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.41 P3 = Coil, Value = 30.82 P4 = Ambient Temp (C), Value = 19.84 P5 = Supply Temp(C), Value = 28.35 P6 = Return Temp(C), Value = 34.14 P7 = Supply Pres(psi), Value = 123.80 P8 = Return Pres(psi), Value = 8.01 14:54:32 Magnet Current for MAIN, Imag = 200.1421 A Vtrans = 2.001367 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:54:32 MAIN (V) Voltage Measurement, V = 31.686639 V 14:54:33 Temperature Measurement, Probe Number = 0, T = 23.433000 C 14:54:34 Temperature Measurement, Probe Number = 1, T = 30.809000 C 14:54:34 Temperature Measurement, Probe Number = 2, T = 19.874000 C 14:54:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321068 V 14:54:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321068 (V, A, ohm, ...), Measured Value = 28.348162 (C, atm, Hz, ...) 14:54:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.740212 V 14:54:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.740212 (V, A, ohm, ...), Measured Value = 34.169606 (C, atm, Hz, ...) 14:54:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665403 V 14:54:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665403 (V, A, ohm, ...), Measured Value = 124.905255 (C, atm, Hz, ...) 14:54:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107054 V 14:54:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107054 (V, A, ohm, ...), Measured Value = 8.029065 (C, atm, Hz, ...) 14:54:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.43 P3 = Coil, Value = 30.81 P4 = Ambient Temp (C), Value = 19.87 P5 = Supply Temp(C), Value = 28.35 P6 = Return Temp(C), Value = 34.17 P7 = Supply Pres(psi), Value = 124.91 P8 = Return Pres(psi), Value = 8.03 14:55:38 Magnet Current for MAIN, Imag = 200.1423 A Vtrans = 2.001368 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:55:38 MAIN (V) Voltage Measurement, V = 31.687149 V 14:55:39 Temperature Measurement, Probe Number = 0, T = 23.450000 C 14:55:40 Temperature Measurement, Probe Number = 1, T = 30.829000 C 14:55:40 Temperature Measurement, Probe Number = 2, T = 19.883000 C 14:55:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321336 V 14:55:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321336 (V, A, ohm, ...), Measured Value = 28.351887 (C, atm, Hz, ...) 14:55:42 Sensor Voltage Measurement, Sensor Number = 1, V = 2.742595 V 14:55:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.742595 (V, A, ohm, ...), Measured Value = 34.202706 (C, atm, Hz, ...) 14:55:43 Sensor Voltage Measurement, Sensor Number = 2, V = 2.650494 V 14:55:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650494 (V, A, ohm, ...), Measured Value = 123.787028 (C, atm, Hz, ...) 14:55:43 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107026 V 14:55:43 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107026 (V, A, ohm, ...), Measured Value = 8.026973 (C, atm, Hz, ...) 14:55:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.45 P3 = Coil, Value = 30.83 P4 = Ambient Temp (C), Value = 19.88 P5 = Supply Temp(C), Value = 28.35 P6 = Return Temp(C), Value = 34.20 P7 = Supply Pres(psi), Value = 123.79 P8 = Return Pres(psi), Value = 8.03 14:56:44 Magnet Current for MAIN, Imag = 200.1424 A Vtrans = 2.001369 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:56:45 MAIN (V) Voltage Measurement, V = 31.687583 V 14:56:45 Temperature Measurement, Probe Number = 0, T = 23.476000 C 14:56:46 Temperature Measurement, Probe Number = 1, T = 30.836000 C 14:56:47 Temperature Measurement, Probe Number = 2, T = 19.884000 C 14:56:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321650 V 14:56:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321650 (V, A, ohm, ...), Measured Value = 28.356249 (C, atm, Hz, ...) 14:56:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.744734 V 14:56:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.744734 (V, A, ohm, ...), Measured Value = 34.232417 (C, atm, Hz, ...) 14:56:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663057 V 14:56:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663057 (V, A, ohm, ...), Measured Value = 124.729275 (C, atm, Hz, ...) 14:56:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107217 V 14:56:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107217 (V, A, ohm, ...), Measured Value = 8.041268 (C, atm, Hz, ...) 14:56:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.48 P3 = Coil, Value = 30.84 P4 = Ambient Temp (C), Value = 19.88 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 34.23 P7 = Supply Pres(psi), Value = 124.73 P8 = Return Pres(psi), Value = 8.04 14:57:50 Magnet Current for MAIN, Imag = 200.1423 A Vtrans = 2.001368 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:57:51 MAIN (V) Voltage Measurement, V = 31.687749 V 14:57:51 Temperature Measurement, Probe Number = 0, T = 23.502000 C 14:57:52 Temperature Measurement, Probe Number = 1, T = 30.837000 C 14:57:53 Temperature Measurement, Probe Number = 2, T = 19.920000 C 14:57:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321607 V 14:57:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321607 (V, A, ohm, ...), Measured Value = 28.355649 (C, atm, Hz, ...) 14:57:54 Sensor Voltage Measurement, Sensor Number = 1, V = 2.747017 V 14:57:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.747017 (V, A, ohm, ...), Measured Value = 34.264124 (C, atm, Hz, ...) 14:57:55 Sensor Voltage Measurement, Sensor Number = 2, V = 2.648930 V 14:57:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648930 (V, A, ohm, ...), Measured Value = 123.669772 (C, atm, Hz, ...) 14:57:55 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107162 V 14:57:55 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107162 (V, A, ohm, ...), Measured Value = 8.037172 (C, atm, Hz, ...) 14:57:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.50 P3 = Coil, Value = 30.84 P4 = Ambient Temp (C), Value = 19.92 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 34.26 P7 = Supply Pres(psi), Value = 123.67 P8 = Return Pres(psi), Value = 8.04 14:58:56 Magnet Current for MAIN, Imag = 200.1429 A Vtrans = 2.001374 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 14:58:57 MAIN (V) Voltage Measurement, V = 31.687839 V 14:58:58 Temperature Measurement, Probe Number = 0, T = 23.525000 C 14:58:58 Temperature Measurement, Probe Number = 1, T = 30.844000 C 14:58:59 Temperature Measurement, Probe Number = 2, T = 19.968000 C 14:58:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.321795 V 14:59:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.321795 (V, A, ohm, ...), Measured Value = 28.358261 (C, atm, Hz, ...) 14:59:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.749299 V 14:59:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.749299 (V, A, ohm, ...), Measured Value = 34.295812 (C, atm, Hz, ...) 14:59:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660070 V 14:59:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660070 (V, A, ohm, ...), Measured Value = 124.505250 (C, atm, Hz, ...) 14:59:01 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107114 V 14:59:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107114 (V, A, ohm, ...), Measured Value = 8.033550 (C, atm, Hz, ...) 14:59:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.52 P3 = Coil, Value = 30.84 P4 = Ambient Temp (C), Value = 19.97 P5 = Supply Temp(C), Value = 28.36 P6 = Return Temp(C), Value = 34.30 P7 = Supply Pres(psi), Value = 124.51 P8 = Return Pres(psi), Value = 8.03 15:00:02 Magnet Current for MAIN, Imag = 200.1438 A Vtrans = 2.001383 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:00:03 MAIN (V) Voltage Measurement, V = 31.688336 V 15:00:04 Temperature Measurement, Probe Number = 0, T = 23.545000 C 15:00:04 Temperature Measurement, Probe Number = 1, T = 30.845000 C 15:00:05 Temperature Measurement, Probe Number = 2, T = 19.992000 C 15:00:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322439 V 15:00:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322439 (V, A, ohm, ...), Measured Value = 28.367211 (C, atm, Hz, ...) 15:00:06 Sensor Voltage Measurement, Sensor Number = 1, V = 2.751835 V 15:00:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.751835 (V, A, ohm, ...), Measured Value = 34.331049 (C, atm, Hz, ...) 15:00:07 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655278 V 15:00:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655278 (V, A, ohm, ...), Measured Value = 124.145850 (C, atm, Hz, ...) 15:00:08 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107106 V 15:00:08 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107106 (V, A, ohm, ...), Measured Value = 8.032973 (C, atm, Hz, ...) 15:00:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.55 P3 = Coil, Value = 30.84 P4 = Ambient Temp (C), Value = 19.99 P5 = Supply Temp(C), Value = 28.37 P6 = Return Temp(C), Value = 34.33 P7 = Supply Pres(psi), Value = 124.15 P8 = Return Pres(psi), Value = 8.03 15:01:08 Magnet Current for MAIN, Imag = 200.1433 A Vtrans = 2.001378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:01:09 MAIN (V) Voltage Measurement, V = 31.688872 V 15:01:10 Temperature Measurement, Probe Number = 0, T = 23.562000 C 15:01:10 Temperature Measurement, Probe Number = 1, T = 30.846000 C 15:01:11 Temperature Measurement, Probe Number = 2, T = 20.000000 C 15:01:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.322808 V 15:01:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.322808 (V, A, ohm, ...), Measured Value = 28.372331 (C, atm, Hz, ...) 15:01:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.753980 V 15:01:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.753980 (V, A, ohm, ...), Measured Value = 34.360831 (C, atm, Hz, ...) 15:01:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.662153 V 15:01:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662153 (V, A, ohm, ...), Measured Value = 124.661497 (C, atm, Hz, ...) 15:01:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107241 V 15:01:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107241 (V, A, ohm, ...), Measured Value = 8.043082 (C, atm, Hz, ...) 15:01:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.56 P3 = Coil, Value = 30.85 P4 = Ambient Temp (C), Value = 20.00 P5 = Supply Temp(C), Value = 28.37 P6 = Return Temp(C), Value = 34.36 P7 = Supply Pres(psi), Value = 124.66 P8 = Return Pres(psi), Value = 8.04 15:02:15 Magnet Current for MAIN, Imag = 200.1434 A Vtrans = 2.001379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:02:15 MAIN (V) Voltage Measurement, V = 31.689523 V 15:02:16 Temperature Measurement, Probe Number = 0, T = 23.582000 C 15:02:17 Temperature Measurement, Probe Number = 1, T = 30.842000 C 15:02:17 Temperature Measurement, Probe Number = 2, T = 20.010000 C 15:02:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323227 V 15:02:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323227 (V, A, ohm, ...), Measured Value = 28.378157 (C, atm, Hz, ...) 15:02:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.756063 V 15:02:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.756063 (V, A, ohm, ...), Measured Value = 34.389765 (C, atm, Hz, ...) 15:02:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660863 V 15:02:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660863 (V, A, ohm, ...), Measured Value = 124.564732 (C, atm, Hz, ...) 15:02:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.107442 V 15:02:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.107442 (V, A, ohm, ...), Measured Value = 8.058142 (C, atm, Hz, ...) 15:02:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.14 P1 = MAIN (V), Value = 31.69 P2 = Magnet Core, Value = 23.58 P3 = Coil, Value = 30.84 P4 = Ambient Temp (C), Value = 20.01 P5 = Supply Temp(C), Value = 28.38 P6 = Return Temp(C), Value = 34.39 P7 = Supply Pres(psi), Value = 124.56 P8 = Return Pres(psi), Value = 8.06 15:02:20 Magnet system MAIN current ramping to 0.0000 A... 15:03:26 Magnet system MAIN current ramping to 200.0000 A... 15:04:33 Magnet system MAIN current ramping to 0.0000 A... 15:05:39 Magnet system MAIN current ramping to 200.0000 A... 15:06:45 Magnet system MAIN current ramping to 0.0000 A... 15:07:52 Magnet system MAIN current ramping to 200.0000 A... 15:08:58 Magnet system MAIN current ramping to 0.0000 A... 15:10:04 Magnet system MAIN current ramping to 200.0000 A... 15:11:11 Magnet system MAIN current ramping to 0.0000 A... 15:12:17 Magnet system MAIN current ramping to 200.0000 A... 15:13:23 Magnet system MAIN current ramping to 0.0000 A... 15:14:29 Magnet system MAIN current ramping to 200.0000 A... 15:15:36 Magnet system MAIN current ramping to 0.0000 A... 15:16:42 Magnet system MAIN current ramping to 200.0000 A... 15:17:48 Magnet system MAIN current ramping to 0.0000 A... 15:18:55 Magnet system MAIN current ramping to 200.0000 A... 15:20:01 Magnet system MAIN current ramping to 0.0000 A... 15:21:07 Magnet system MAIN current ramping to 200.0000 A... 15:22:14 Magnet system MAIN current ramping to 0.0000 A... 15:23:20 Magnet system MAIN current ramping to 200.0000 A... 15:24:26 Magnet system MAIN current ramping to 0.0000 A... 15:25:35 Position moved: 0.000000 m 15:25:38 Magnet system MAIN current ramping to 0.0000 A... 15:25:49 Magnet Current for MAIN, Imag = 0.0077 A Vtrans = 0.000023 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:25:50 MAIN (V) Voltage Measurement, V = 0.000546 V 15:25:50 Temperature Measurement, Probe Number = 0, T = 23.809000 C 15:25:51 Temperature Measurement, Probe Number = 1, T = 28.955000 C 15:25:52 Temperature Measurement, Probe Number = 2, T = 20.409000 C 15:25:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.323966 V 15:25:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.323966 (V, A, ohm, ...), Measured Value = 28.388414 (C, atm, Hz, ...) 15:25:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.510424 V 15:25:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.510424 (V, A, ohm, ...), Measured Value = 30.978106 (C, atm, Hz, ...) 15:25:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657228 V 15:25:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657228 (V, A, ohm, ...), Measured Value = 124.292093 (C, atm, Hz, ...) 15:25:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106204 V 15:25:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106204 (V, A, ohm, ...), Measured Value = 7.965292 (C, atm, Hz, ...) 15:25:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Magnet Core, Value = 23.81 P3 = Coil, Value = 28.95 P4 = Ambient Temp (C), Value = 20.41 P5 = Supply Temp(C), Value = 28.39 P6 = Return Temp(C), Value = 30.98 P7 = Supply Pres(psi), Value = 124.29 P8 = Return Pres(psi), Value = 7.97 15:25:54 Magnetic Field Measurement Measuring the magnet strength... 15:25:55 Integrated Voltage Measurement... 15:25:55 Magnet Current for MAIN, Imag = 0.0076 A Vtrans = 0.000021 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:26:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000114474 Vs 15:26:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000133550 Vs 15:26:11 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000021 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:26:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000105250 Vs 15:26:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000122700 Vs 15:26:25 Magnet Current for MAIN, Imag = 0.0075 A Vtrans = 0.000021 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000099995 Vs 15:26:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000115457 Vs 15:26:40 Magnet Current for MAIN, Imag = 0.0072 A Vtrans = 0.000017 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:26:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000097108 Vs 15:26:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000110117 Vs 15:26:54 Magnet Current for MAIN, Imag = 0.0072 A Vtrans = 0.000018 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:27:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000095419 Vs 15:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000106986 Vs 15:27:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000110106 +- 0.000008191 Vs 15:27:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.000110106 +- 0.000008191 Vs BL = 0.00122339 +- 0.00009101 Tm 15:27:12 Position moved: 0.000000 m 15:27:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00122 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00122 0.00009 0.00122 0.00000 15:27:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00122 0.00009 SL = 0.0012234 +- 0.0000910 Tm^2/m^n 15:27:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0012234 +- 0.0000910 Tm^2/m^n 15:27:15 Position moved: 0.000000 m 15:27:15 Magnet system MAIN current ramping to 20.0000 A... 15:27:32 Magnet Current for MAIN, Imag = 19.9741 A Vtrans = 0.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:27:32 MAIN (V) Voltage Measurement, V = 3.097728 V 15:27:33 Temperature Measurement, Probe Number = 0, T = 23.824000 C 15:27:34 Temperature Measurement, Probe Number = 1, T = 28.624000 C 15:27:34 Temperature Measurement, Probe Number = 2, T = 20.400000 C 15:27:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324627 V 15:27:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324627 (V, A, ohm, ...), Measured Value = 28.397593 (C, atm, Hz, ...) 15:27:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.501679 V 15:27:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.501679 (V, A, ohm, ...), Measured Value = 30.856647 (C, atm, Hz, ...) 15:27:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663254 V 15:27:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663254 (V, A, ohm, ...), Measured Value = 124.744050 (C, atm, Hz, ...) 15:27:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106529 V 15:27:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106529 (V, A, ohm, ...), Measured Value = 7.989698 (C, atm, Hz, ...) 15:27:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.97 P1 = MAIN (V), Value = 3.10 P2 = Magnet Core, Value = 23.82 P3 = Coil, Value = 28.62 P4 = Ambient Temp (C), Value = 20.40 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 30.86 P7 = Supply Pres(psi), Value = 124.74 P8 = Return Pres(psi), Value = 7.99 15:27:37 Magnetic Field Measurement Measuring the magnet strength... 15:27:37 Integrated Voltage Measurement... 15:27:38 Magnet Current for MAIN, Imag = 19.9741 A Vtrans = 0.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:27:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007956413 Vs 15:27:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.007961487 Vs 15:27:54 Magnet Current for MAIN, Imag = 19.9740 A Vtrans = 0.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007959524 Vs 15:28:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.007962100 Vs 15:28:08 Magnet Current for MAIN, Imag = 19.9740 A Vtrans = 0.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:28:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007960459 Vs 15:28:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.007961211 Vs 15:28:23 Magnet Current for MAIN, Imag = 19.9742 A Vtrans = 0.199687 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:28:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007960885 Vs 15:28:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.007960501 Vs 15:28:38 Magnet Current for MAIN, Imag = 19.9740 A Vtrans = 0.199686 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:28:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007959963 Vs 15:28:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.007960840 Vs 15:28:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.007960338 +- 0.000000711 Vs 15:28:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.007960338 +- 0.000000711 Vs BL = 0.08844820 +- 0.00000790 Tm 15:28:55 Position moved: 0.000000 m 15:28:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.08845 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.08845 0.00001 0.08845 0.00000 15:28:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.08845 0.00001 SL = 0.0884482 +- 0.0000079 Tm^2/m^n 15:28:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0884482 +- 0.0000079 Tm^2/m^n 15:28:58 Position moved: 0.000000 m 15:28:58 Magnet system MAIN current ramping to 40.0000 A... 15:29:15 Magnet Current for MAIN, Imag = 39.9600 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:29:16 MAIN (V) Voltage Measurement, V = 6.185712 V 15:29:16 Temperature Measurement, Probe Number = 0, T = 23.835000 C 15:29:17 Temperature Measurement, Probe Number = 1, T = 28.209000 C 15:29:18 Temperature Measurement, Probe Number = 2, T = 20.419000 C 15:29:18 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324402 V 15:29:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324402 (V, A, ohm, ...), Measured Value = 28.394468 (C, atm, Hz, ...) 15:29:19 Sensor Voltage Measurement, Sensor Number = 1, V = 2.473060 V 15:29:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.473060 (V, A, ohm, ...), Measured Value = 30.459171 (C, atm, Hz, ...) 15:29:20 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665133 V 15:29:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665133 (V, A, ohm, ...), Measured Value = 124.884952 (C, atm, Hz, ...) 15:29:20 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106272 V 15:29:20 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106272 (V, A, ohm, ...), Measured Value = 7.970437 (C, atm, Hz, ...) 15:29:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = 6.19 P2 = Magnet Core, Value = 23.84 P3 = Coil, Value = 28.21 P4 = Ambient Temp (C), Value = 20.42 P5 = Supply Temp(C), Value = 28.39 P6 = Return Temp(C), Value = 30.46 P7 = Supply Pres(psi), Value = 124.88 P8 = Return Pres(psi), Value = 7.97 15:29:20 Magnetic Field Measurement Measuring the magnet strength... 15:29:20 Integrated Voltage Measurement... 15:29:21 Magnet Current for MAIN, Imag = 39.9602 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:29:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015829179 Vs 15:29:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015835031 Vs 15:29:37 Magnet Current for MAIN, Imag = 39.9600 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:29:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015833157 Vs 15:29:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015837533 Vs 15:29:51 Magnet Current for MAIN, Imag = 39.9598 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:29:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015836774 Vs 15:30:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015838048 Vs 15:30:06 Magnet Current for MAIN, Imag = 39.9600 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:30:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015834954 Vs 15:30:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015838442 Vs 15:30:21 Magnet Current for MAIN, Imag = 39.9599 A Vtrans = 0.399544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:30:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015834796 Vs 15:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015839723 Vs 15:30:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015835764 +- 0.000001969 Vs 15:30:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.015835764 +- 0.000001969 Vs BL = 0.17595293 +- 0.00002188 Tm 15:30:38 Position moved: 0.000000 m 15:30:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.17595 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.17595 0.00002 0.17595 0.00000 15:30:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.17595 0.00002 SL = 0.1759529 +- 0.0000219 Tm^2/m^n 15:30:38 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1759529 +- 0.0000219 Tm^2/m^n 15:30:41 Position moved: 0.000000 m 15:30:41 Magnet system MAIN current ramping to 60.0000 A... 15:30:58 Magnet Current for MAIN, Imag = 60.0137 A Vtrans = 0.600082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:30:58 MAIN (V) Voltage Measurement, V = 9.287899 V 15:30:59 Temperature Measurement, Probe Number = 0, T = 23.834000 C 15:31:00 Temperature Measurement, Probe Number = 1, T = 27.954000 C 15:31:00 Temperature Measurement, Probe Number = 2, T = 20.450000 C 15:31:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324437 V 15:31:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324437 (V, A, ohm, ...), Measured Value = 28.394963 (C, atm, Hz, ...) 15:31:02 Sensor Voltage Measurement, Sensor Number = 1, V = 2.435925 V 15:31:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.435925 (V, A, ohm, ...), Measured Value = 29.943399 (C, atm, Hz, ...) 15:31:02 Sensor Voltage Measurement, Sensor Number = 2, V = 2.668744 V 15:31:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668744 (V, A, ohm, ...), Measured Value = 125.155785 (C, atm, Hz, ...) 15:31:03 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106111 V 15:31:03 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106111 (V, A, ohm, ...), Measured Value = 7.958332 (C, atm, Hz, ...) 15:31:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 60.01 P1 = MAIN (V), Value = 9.29 P2 = Magnet Core, Value = 23.83 P3 = Coil, Value = 27.95 P4 = Ambient Temp (C), Value = 20.45 P5 = Supply Temp(C), Value = 28.39 P6 = Return Temp(C), Value = 29.94 P7 = Supply Pres(psi), Value = 125.16 P8 = Return Pres(psi), Value = 7.96 15:31:03 Magnetic Field Measurement Measuring the magnet strength... 15:31:03 Integrated Voltage Measurement... 15:31:04 Magnet Current for MAIN, Imag = 60.0137 A Vtrans = 0.600082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:31:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023730699 Vs 15:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023743343 Vs 15:31:19 Magnet Current for MAIN, Imag = 60.0138 A Vtrans = 0.600084 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023740865 Vs 15:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023745557 Vs 15:31:34 Magnet Current for MAIN, Imag = 60.0133 A Vtrans = 0.600078 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023745386 Vs 15:31:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023746583 Vs 15:31:49 Magnet Current for MAIN, Imag = 60.0135 A Vtrans = 0.600081 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:31:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023747560 Vs 15:32:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023748557 Vs 15:32:03 Magnet Current for MAIN, Imag = 60.0139 A Vtrans = 0.600084 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:32:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023747029 Vs 15:32:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023748840 Vs 15:32:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023744442 +- 0.000004105 Vs 15:32:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.023744442 +- 0.000004105 Vs BL = 0.26382713 +- 0.00004561 Tm 15:32:21 Position moved: 0.000000 m 15:32:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.26383 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.26383 0.00005 0.26383 0.00000 15:32:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.26383 0.00005 SL = 0.2638271 +- 0.0000456 Tm^2/m^n 15:32:21 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2638271 +- 0.0000456 Tm^2/m^n 15:32:24 Position moved: 0.000000 m 15:32:24 Magnet system MAIN current ramping to 80.0000 A... 15:32:40 Magnet Current for MAIN, Imag = 80.0097 A Vtrans = 0.800043 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:32:41 MAIN (V) Voltage Measurement, V = 12.391656 V 15:32:42 Temperature Measurement, Probe Number = 0, T = 23.831000 C 15:32:42 Temperature Measurement, Probe Number = 1, T = 27.838000 C 15:32:43 Temperature Measurement, Probe Number = 2, T = 20.467000 C 15:32:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325006 V 15:32:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325006 (V, A, ohm, ...), Measured Value = 28.402854 (C, atm, Hz, ...) 15:32:44 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402653 V 15:32:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402653 (V, A, ohm, ...), Measured Value = 29.481289 (C, atm, Hz, ...) 15:32:45 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652555 V 15:32:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652555 (V, A, ohm, ...), Measured Value = 123.941655 (C, atm, Hz, ...) 15:32:46 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106116 V 15:32:46 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106116 (V, A, ohm, ...), Measured Value = 7.958715 (C, atm, Hz, ...) 15:32:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.01 P1 = MAIN (V), Value = 12.39 P2 = Magnet Core, Value = 23.83 P3 = Coil, Value = 27.84 P4 = Ambient Temp (C), Value = 20.47 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.48 P7 = Supply Pres(psi), Value = 123.94 P8 = Return Pres(psi), Value = 7.96 15:32:46 Magnetic Field Measurement Measuring the magnet strength... 15:32:46 Integrated Voltage Measurement... 15:32:47 Magnet Current for MAIN, Imag = 80.0095 A Vtrans = 0.800041 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:32:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031626035 Vs 15:33:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031631180 Vs 15:33:02 Magnet Current for MAIN, Imag = 80.0092 A Vtrans = 0.800038 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:33:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031639337 Vs 15:33:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031639626 Vs 15:33:17 Magnet Current for MAIN, Imag = 80.0094 A Vtrans = 0.800039 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:33:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031641179 Vs 15:33:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031637620 Vs 15:33:31 Magnet Current for MAIN, Imag = 80.0096 A Vtrans = 0.800041 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:33:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031642095 Vs 15:33:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031638115 Vs 15:33:46 Magnet Current for MAIN, Imag = 80.0095 A Vtrans = 0.800040 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:33:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031643236 Vs 15:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031641176 Vs 15:34:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031637960 +- 0.000004785 Vs 15:34:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.031637960 +- 0.000004785 Vs BL = 0.35153289 +- 0.00005317 Tm 15:34:04 Position moved: 0.000000 m 15:34:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.35153 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.35153 0.00005 0.35153 0.00000 15:34:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.35153 0.00005 SL = 0.3515329 +- 0.0000532 Tm^2/m^n 15:34:04 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3515329 +- 0.0000532 Tm^2/m^n 15:34:07 Position moved: 0.000000 m 15:34:07 Magnet system MAIN current ramping to 100.0000 A... 15:34:24 Magnet Current for MAIN, Imag = 100.0627 A Vtrans = 1.000573 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:34:24 MAIN (V) Voltage Measurement, V = 15.518657 V 15:34:25 Temperature Measurement, Probe Number = 0, T = 23.841000 C 15:34:26 Temperature Measurement, Probe Number = 1, T = 27.859000 C 15:34:26 Temperature Measurement, Probe Number = 2, T = 20.502000 C 15:34:27 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324986 V 15:34:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324986 (V, A, ohm, ...), Measured Value = 28.402589 (C, atm, Hz, ...) 15:34:27 Sensor Voltage Measurement, Sensor Number = 1, V = 2.378712 V 15:34:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378712 (V, A, ohm, ...), Measured Value = 29.148781 (C, atm, Hz, ...) 15:34:28 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669009 V 15:34:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669009 (V, A, ohm, ...), Measured Value = 125.175705 (C, atm, Hz, ...) 15:34:29 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105928 V 15:34:29 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105928 (V, A, ohm, ...), Measured Value = 7.944600 (C, atm, Hz, ...) 15:34:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.06 P1 = MAIN (V), Value = 15.52 P2 = Magnet Core, Value = 23.84 P3 = Coil, Value = 27.86 P4 = Ambient Temp (C), Value = 20.50 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.15 P7 = Supply Pres(psi), Value = 125.18 P8 = Return Pres(psi), Value = 7.94 15:34:29 Magnetic Field Measurement Measuring the magnet strength... 15:34:29 Integrated Voltage Measurement... 15:34:30 Magnet Current for MAIN, Imag = 100.0628 A Vtrans = 1.000573 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039522016 Vs 15:34:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039530319 Vs 15:34:45 Magnet Current for MAIN, Imag = 100.0628 A Vtrans = 1.000573 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039547188 Vs 15:34:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039534094 Vs 15:35:00 Magnet Current for MAIN, Imag = 100.0625 A Vtrans = 1.000571 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:35:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039543282 Vs 15:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039536472 Vs 15:35:14 Magnet Current for MAIN, Imag = 100.0625 A Vtrans = 1.000571 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:35:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039544449 Vs 15:35:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039538867 Vs 15:35:29 Magnet Current for MAIN, Imag = 100.0624 A Vtrans = 1.000569 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:35:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039544519 Vs 15:35:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039543224 Vs 15:35:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039538443 +- 0.000006283 Vs 15:35:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.039538443 +- 0.000006283 Vs BL = 0.43931603 +- 0.00006981 Tm 15:35:47 Position moved: 0.000000 m 15:35:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.43932 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.43932 0.00007 0.43932 0.00000 15:35:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.43932 0.00007 SL = 0.4393160 +- 0.0000698 Tm^2/m^n 15:35:47 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4393160 +- 0.0000698 Tm^2/m^n 15:35:50 Position moved: 0.000000 m 15:35:50 Magnet system MAIN current ramping to 120.0000 A... 15:36:06 Magnet Current for MAIN, Imag = 120.0526 A Vtrans = 1.200472 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:36:07 MAIN (V) Voltage Measurement, V = 18.654514 V 15:36:08 Temperature Measurement, Probe Number = 0, T = 23.846000 C 15:36:08 Temperature Measurement, Probe Number = 1, T = 27.986000 C 15:36:09 Temperature Measurement, Probe Number = 2, T = 20.517000 C 15:36:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324886 V 15:36:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324886 (V, A, ohm, ...), Measured Value = 28.401194 (C, atm, Hz, ...) 15:36:10 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366388 V 15:36:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366388 (V, A, ohm, ...), Measured Value = 28.977608 (C, atm, Hz, ...) 15:36:11 Sensor Voltage Measurement, Sensor Number = 2, V = 2.666793 V 15:36:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666793 (V, A, ohm, ...), Measured Value = 125.009452 (C, atm, Hz, ...) 15:36:12 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105743 V 15:36:12 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105743 (V, A, ohm, ...), Measured Value = 7.930688 (C, atm, Hz, ...) 15:36:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.05 P1 = MAIN (V), Value = 18.65 P2 = Magnet Core, Value = 23.85 P3 = Coil, Value = 27.99 P4 = Ambient Temp (C), Value = 20.52 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 28.98 P7 = Supply Pres(psi), Value = 125.01 P8 = Return Pres(psi), Value = 7.93 15:36:12 Magnetic Field Measurement Measuring the magnet strength... 15:36:12 Integrated Voltage Measurement... 15:36:12 Magnet Current for MAIN, Imag = 120.0526 A Vtrans = 1.200472 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:36:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047357111 Vs 15:36:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047348938 Vs 15:36:28 Magnet Current for MAIN, Imag = 120.0526 A Vtrans = 1.200472 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:36:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047369212 Vs 15:36:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047359794 Vs 15:36:43 Magnet Current for MAIN, Imag = 120.0529 A Vtrans = 1.200474 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:36:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047370009 Vs 15:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047366310 Vs 15:36:57 Magnet Current for MAIN, Imag = 120.0530 A Vtrans = 1.200476 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:37:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047374762 Vs 15:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047365999 Vs 15:37:12 Magnet Current for MAIN, Imag = 120.0529 A Vtrans = 1.200474 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047374439 Vs 15:37:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047367582 Vs 15:37:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047365415 +- 0.000006601 Vs 15:37:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.047365415 +- 0.000006601 Vs BL = 0.52628239 +- 0.00007334 Tm 15:37:30 Position moved: 0.000000 m 15:37:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.52628 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.52628 0.00007 0.52628 0.00000 15:37:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.52628 0.00007 SL = 0.5262824 +- 0.0000733 Tm^2/m^n 15:37:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5262824 +- 0.0000733 Tm^2/m^n 15:37:33 Position moved: 0.000000 m 15:37:33 Magnet system MAIN current ramping to 140.0000 A... 15:37:49 Magnet Current for MAIN, Imag = 140.0997 A Vtrans = 1.400942 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:37:50 MAIN (V) Voltage Measurement, V = 21.822590 V 15:37:50 Temperature Measurement, Probe Number = 0, T = 23.857000 C 15:37:51 Temperature Measurement, Probe Number = 1, T = 28.185000 C 15:37:52 Temperature Measurement, Probe Number = 2, T = 20.535000 C 15:37:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324857 V 15:37:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324857 (V, A, ohm, ...), Measured Value = 28.400789 (C, atm, Hz, ...) 15:37:53 Sensor Voltage Measurement, Sensor Number = 1, V = 2.366383 V 15:37:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.366383 (V, A, ohm, ...), Measured Value = 28.977539 (C, atm, Hz, ...) 15:37:54 Sensor Voltage Measurement, Sensor Number = 2, V = 2.651689 V 15:37:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651689 (V, A, ohm, ...), Measured Value = 123.876638 (C, atm, Hz, ...) 15:37:54 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105451 V 15:37:54 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105451 (V, A, ohm, ...), Measured Value = 7.908855 (C, atm, Hz, ...) 15:37:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 140.10 P1 = MAIN (V), Value = 21.82 P2 = Magnet Core, Value = 23.86 P3 = Coil, Value = 28.18 P4 = Ambient Temp (C), Value = 20.54 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 28.98 P7 = Supply Pres(psi), Value = 123.88 P8 = Return Pres(psi), Value = 7.91 15:37:54 Magnetic Field Measurement Measuring the magnet strength... 15:37:54 Integrated Voltage Measurement... 15:37:55 Magnet Current for MAIN, Imag = 140.1001 A Vtrans = 1.400946 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055121299 Vs 15:38:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055116484 Vs 15:38:11 Magnet Current for MAIN, Imag = 140.0998 A Vtrans = 1.400943 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:38:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055138000 Vs 15:38:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055131883 Vs 15:38:25 Magnet Current for MAIN, Imag = 140.0994 A Vtrans = 1.400940 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:38:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055135964 Vs 15:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055134987 Vs 15:38:40 Magnet Current for MAIN, Imag = 140.1001 A Vtrans = 1.400946 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:38:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055138086 Vs 15:38:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055138276 Vs 15:38:54 Magnet Current for MAIN, Imag = 140.1001 A Vtrans = 1.400946 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:39:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055139409 Vs 15:39:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055137651 Vs 15:39:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055133204 +- 0.000007296 Vs 15:39:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.055133204 +- 0.000007296 Vs BL = 0.61259116 +- 0.00008107 Tm 15:39:12 Position moved: 0.000000 m 15:39:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.61259 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.61259 0.00008 0.61259 0.00000 15:39:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.61259 0.00008 SL = 0.6125912 +- 0.0000811 Tm^2/m^n 15:39:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6125912 +- 0.0000811 Tm^2/m^n 15:39:15 Position moved: 0.000000 m 15:39:15 Magnet system MAIN current ramping to 160.0000 A... 15:39:32 Magnet Current for MAIN, Imag = 160.1081 A Vtrans = 1.601026 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:39:32 MAIN (V) Voltage Measurement, V = 25.012321 V 15:39:33 Temperature Measurement, Probe Number = 0, T = 23.868000 C 15:39:33 Temperature Measurement, Probe Number = 1, T = 28.452000 C 15:39:34 Temperature Measurement, Probe Number = 2, T = 20.538000 C 15:39:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324651 V 15:39:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324651 (V, A, ohm, ...), Measured Value = 28.397929 (C, atm, Hz, ...) 15:39:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.378446 V 15:39:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.378446 (V, A, ohm, ...), Measured Value = 29.145090 (C, atm, Hz, ...) 15:39:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665522 V 15:39:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665522 (V, A, ohm, ...), Measured Value = 124.914120 (C, atm, Hz, ...) 15:39:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105656 V 15:39:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105656 (V, A, ohm, ...), Measured Value = 7.924200 (C, atm, Hz, ...) 15:39:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.11 P1 = MAIN (V), Value = 25.01 P2 = Magnet Core, Value = 23.87 P3 = Coil, Value = 28.45 P4 = Ambient Temp (C), Value = 20.54 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.15 P7 = Supply Pres(psi), Value = 124.91 P8 = Return Pres(psi), Value = 7.92 15:39:37 Magnetic Field Measurement Measuring the magnet strength... 15:39:37 Integrated Voltage Measurement... 15:39:38 Magnet Current for MAIN, Imag = 160.1079 A Vtrans = 1.601025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:39:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062766633 Vs 15:39:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.062736497 Vs 15:39:53 Magnet Current for MAIN, Imag = 160.1079 A Vtrans = 1.601025 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:40:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062767011 Vs 15:40:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.062749700 Vs 15:40:08 Magnet Current for MAIN, Imag = 160.1086 A Vtrans = 1.601031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062765555 Vs 15:40:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.062761513 Vs 15:40:22 Magnet Current for MAIN, Imag = 160.1087 A Vtrans = 1.601032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:40:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062758078 Vs 15:40:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.062755242 Vs 15:40:37 Magnet Current for MAIN, Imag = 160.1086 A Vtrans = 1.601031 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:40:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062761615 Vs 15:40:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.062757424 Vs 15:40:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062757927 +- 0.000003905 Vs 15:40:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.062757927 +- 0.000003905 Vs BL = 0.69731030 +- 0.00004339 Tm 15:40:54 Position moved: 0.000000 m 15:40:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.69731 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.69731 0.00004 0.69731 0.00000 15:40:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.69731 0.00004 SL = 0.6973103 +- 0.0000434 Tm^2/m^n 15:40:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6973103 +- 0.0000434 Tm^2/m^n 15:40:57 Position moved: 0.000000 m 15:40:57 Magnet system MAIN current ramping to 180.0000 A... 15:41:14 Magnet Current for MAIN, Imag = 180.1592 A Vtrans = 1.801537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:41:15 MAIN (V) Voltage Measurement, V = 28.240105 V 15:41:15 Temperature Measurement, Probe Number = 0, T = 23.889000 C 15:41:16 Temperature Measurement, Probe Number = 1, T = 28.819000 C 15:41:17 Temperature Measurement, Probe Number = 2, T = 20.588000 C 15:41:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324732 V 15:41:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324732 (V, A, ohm, ...), Measured Value = 28.399058 (C, atm, Hz, ...) 15:41:18 Sensor Voltage Measurement, Sensor Number = 1, V = 2.402467 V 15:41:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.402467 (V, A, ohm, ...), Measured Value = 29.478713 (C, atm, Hz, ...) 15:41:19 Sensor Voltage Measurement, Sensor Number = 2, V = 2.660566 V 15:41:19 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660566 (V, A, ohm, ...), Measured Value = 124.542427 (C, atm, Hz, ...) 15:41:19 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105917 V 15:41:19 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105917 (V, A, ohm, ...), Measured Value = 7.943745 (C, atm, Hz, ...) 15:41:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.16 P1 = MAIN (V), Value = 28.24 P2 = Magnet Core, Value = 23.89 P3 = Coil, Value = 28.82 P4 = Ambient Temp (C), Value = 20.59 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.48 P7 = Supply Pres(psi), Value = 124.54 P8 = Return Pres(psi), Value = 7.94 15:41:19 Magnetic Field Measurement Measuring the magnet strength... 15:41:19 Integrated Voltage Measurement... 15:41:20 Magnet Current for MAIN, Imag = 180.1592 A Vtrans = 1.801537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070073584 Vs 15:41:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070062554 Vs 15:41:36 Magnet Current for MAIN, Imag = 180.1594 A Vtrans = 1.801540 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:41:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070075357 Vs 15:41:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070068333 Vs 15:41:50 Magnet Current for MAIN, Imag = 180.1594 A Vtrans = 1.801540 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:41:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070072661 Vs 15:42:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070077203 Vs 15:42:05 Magnet Current for MAIN, Imag = 180.1590 A Vtrans = 1.801536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:42:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070074540 Vs 15:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070069444 Vs 15:42:19 Magnet Current for MAIN, Imag = 180.1592 A Vtrans = 1.801537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070082945 Vs 15:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070075825 Vs 15:42:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070073244 +- 0.000003765 Vs 15:42:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.070073244 +- 0.000003765 Vs BL = 0.77859161 +- 0.00004183 Tm 15:42:37 Position moved: 0.000000 m 15:42:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.77859 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.77859 0.00004 0.77859 0.00000 15:42:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.77859 0.00004 SL = 0.7785916 +- 0.0000418 Tm^2/m^n 15:42:37 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7785916 +- 0.0000418 Tm^2/m^n 15:42:40 Position moved: 0.000000 m 15:42:40 Magnet system MAIN current ramping to 200.0000 A... 15:42:57 Magnet Current for MAIN, Imag = 200.1475 A Vtrans = 2.001420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:42:57 MAIN (V) Voltage Measurement, V = 31.494430 V 15:42:58 Temperature Measurement, Probe Number = 0, T = 23.914000 C 15:42:58 Temperature Measurement, Probe Number = 1, T = 29.227000 C 15:42:59 Temperature Measurement, Probe Number = 2, T = 20.590000 C 15:43:00 Sensor Voltage Measurement, Sensor Number = 0, V = 2.324901 V 15:43:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.324901 (V, A, ohm, ...), Measured Value = 28.401407 (C, atm, Hz, ...) 15:43:00 Sensor Voltage Measurement, Sensor Number = 1, V = 2.436706 V 15:43:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.436706 (V, A, ohm, ...), Measured Value = 29.954256 (C, atm, Hz, ...) 15:43:01 Sensor Voltage Measurement, Sensor Number = 2, V = 2.669457 V 15:43:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669457 (V, A, ohm, ...), Measured Value = 125.209268 (C, atm, Hz, ...) 15:43:02 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105756 V 15:43:02 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105756 (V, A, ohm, ...), Measured Value = 7.931730 (C, atm, Hz, ...) 15:43:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.15 P1 = MAIN (V), Value = 31.49 P2 = Magnet Core, Value = 23.91 P3 = Coil, Value = 29.23 P4 = Ambient Temp (C), Value = 20.59 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.95 P7 = Supply Pres(psi), Value = 125.21 P8 = Return Pres(psi), Value = 7.93 15:43:02 Magnetic Field Measurement Measuring the magnet strength... 15:43:02 Integrated Voltage Measurement... 15:43:03 Magnet Current for MAIN, Imag = 200.1475 A Vtrans = 2.001420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:43:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076604029 Vs 15:43:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.076610453 Vs 15:43:18 Magnet Current for MAIN, Imag = 200.1472 A Vtrans = 2.001418 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:43:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076619476 Vs 15:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.076626769 Vs 15:43:33 Magnet Current for MAIN, Imag = 200.1476 A Vtrans = 2.001421 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:43:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076626649 Vs 15:43:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.076625057 Vs 15:43:47 Magnet Current for MAIN, Imag = 200.1475 A Vtrans = 2.001420 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076623207 Vs 15:44:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.076618338 Vs 15:44:02 Magnet Current for MAIN, Imag = 200.1477 A Vtrans = 2.001423 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076620336 Vs 15:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.076624053 Vs 15:44:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.076619837 +- 0.000006513 Vs 15:44:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.076619837 +- 0.000006513 Vs BL = 0.85133152 +- 0.00007236 Tm 15:44:20 Position moved: 0.000000 m 15:44:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.85133 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.85133 0.00007 0.85133 0.00000 15:44:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.85133 0.00007 SL = 0.8513315 +- 0.0000724 Tm^2/m^n 15:44:20 Magnet Strength Measurement Harmonic Number = 1 SL = 0.8513315 +- 0.0000724 Tm^2/m^n 15:44:23 Position moved: 0.000000 m 15:44:23 Magnet system MAIN current ramping to 180.0000 A... 15:44:39 Magnet Current for MAIN, Imag = 180.1595 A Vtrans = 1.801541 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:44:40 MAIN (V) Voltage Measurement, V = 28.438440 V 15:44:40 Temperature Measurement, Probe Number = 0, T = 23.950000 C 15:44:41 Temperature Measurement, Probe Number = 1, T = 29.716000 C 15:44:42 Temperature Measurement, Probe Number = 2, T = 20.579000 C 15:44:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325083 V 15:44:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325083 (V, A, ohm, ...), Measured Value = 28.403931 (C, atm, Hz, ...) 15:44:43 Sensor Voltage Measurement, Sensor Number = 1, V = 2.478170 V 15:44:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.478170 (V, A, ohm, ...), Measured Value = 30.530140 (C, atm, Hz, ...) 15:44:44 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664329 V 15:44:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664329 (V, A, ohm, ...), Measured Value = 124.824697 (C, atm, Hz, ...) 15:44:44 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105917 V 15:44:44 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105917 (V, A, ohm, ...), Measured Value = 7.943745 (C, atm, Hz, ...) 15:44:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.16 P1 = MAIN (V), Value = 28.44 P2 = Magnet Core, Value = 23.95 P3 = Coil, Value = 29.72 P4 = Ambient Temp (C), Value = 20.58 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 30.53 P7 = Supply Pres(psi), Value = 124.82 P8 = Return Pres(psi), Value = 7.94 15:44:45 Magnetic Field Measurement Measuring the magnet strength... 15:44:45 Integrated Voltage Measurement... 15:44:45 Magnet Current for MAIN, Imag = 180.1597 A Vtrans = 1.801542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:44:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070363121 Vs 15:45:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070359233 Vs 15:45:01 Magnet Current for MAIN, Imag = 180.1597 A Vtrans = 1.801542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:45:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070351450 Vs 15:45:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070353630 Vs 15:45:16 Magnet Current for MAIN, Imag = 180.1599 A Vtrans = 1.801545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:45:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070346963 Vs 15:45:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070345282 Vs 15:45:30 Magnet Current for MAIN, Imag = 180.1597 A Vtrans = 1.801542 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070353818 Vs 15:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070351135 Vs 15:45:45 Magnet Current for MAIN, Imag = 180.1599 A Vtrans = 1.801545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070352505 Vs 15:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.070350628 Vs 15:45:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.070352776 +- 0.000004826 Vs 15:45:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.070352776 +- 0.000004826 Vs BL = 0.78169752 +- 0.00005362 Tm 15:46:03 Position moved: 0.000000 m 15:46:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.78170 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.78170 0.00005 0.78170 0.00000 15:46:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.78170 0.00005 SL = 0.7816975 +- 0.0000536 Tm^2/m^n 15:46:03 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7816975 +- 0.0000536 Tm^2/m^n 15:46:06 Position moved: 0.000000 m 15:46:06 Magnet system MAIN current ramping to 160.0000 A... 15:46:22 Magnet Current for MAIN, Imag = 160.1107 A Vtrans = 1.601053 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:46:23 MAIN (V) Voltage Measurement, V = 25.240606 V 15:46:23 Temperature Measurement, Probe Number = 0, T = 23.989000 C 15:46:24 Temperature Measurement, Probe Number = 1, T = 30.107000 C 15:46:25 Temperature Measurement, Probe Number = 2, T = 20.515000 C 15:46:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325393 V 15:46:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325393 (V, A, ohm, ...), Measured Value = 28.408239 (C, atm, Hz, ...) 15:46:26 Sensor Voltage Measurement, Sensor Number = 1, V = 2.522634 V 15:46:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.522634 (V, A, ohm, ...), Measured Value = 31.147692 (C, atm, Hz, ...) 15:46:27 Sensor Voltage Measurement, Sensor Number = 2, V = 2.654635 V 15:46:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654635 (V, A, ohm, ...), Measured Value = 124.097617 (C, atm, Hz, ...) 15:46:27 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106009 V 15:46:27 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106009 (V, A, ohm, ...), Measured Value = 7.950705 (C, atm, Hz, ...) 15:46:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 160.11 P1 = MAIN (V), Value = 25.24 P2 = Magnet Core, Value = 23.99 P3 = Coil, Value = 30.11 P4 = Ambient Temp (C), Value = 20.52 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 31.15 P7 = Supply Pres(psi), Value = 124.10 P8 = Return Pres(psi), Value = 7.95 15:46:28 Magnetic Field Measurement Measuring the magnet strength... 15:46:28 Integrated Voltage Measurement... 15:46:28 Magnet Current for MAIN, Imag = 160.1117 A Vtrans = 1.601063 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062998962 Vs 15:46:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.063032780 Vs 15:46:44 Magnet Current for MAIN, Imag = 160.1114 A Vtrans = 1.601059 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:46:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.063002251 Vs 15:46:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.063016719 Vs 15:46:59 Magnet Current for MAIN, Imag = 160.1116 A Vtrans = 1.601062 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:47:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062993989 Vs 15:47:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.063010540 Vs 15:47:13 Magnet Current for MAIN, Imag = 160.1119 A Vtrans = 1.601064 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:47:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.063003268 Vs 15:47:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.063003949 Vs 15:47:28 Magnet Current for MAIN, Imag = 160.1121 A Vtrans = 1.601067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.062999243 Vs 15:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.063001445 Vs 15:47:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.063006315 +- 0.000005670 Vs 15:47:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.063006315 +- 0.000005670 Vs BL = 0.70007016 +- 0.00006300 Tm 15:47:46 Position moved: 0.000000 m 15:47:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.70007 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.70007 0.00006 0.70007 0.00000 15:47:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.70007 0.00006 SL = 0.7000702 +- 0.0000630 Tm^2/m^n 15:47:46 Magnet Strength Measurement Harmonic Number = 1 SL = 0.7000702 +- 0.0000630 Tm^2/m^n 15:47:49 Position moved: 0.000000 m 15:47:49 Magnet system MAIN current ramping to 140.0000 A... 15:48:05 Magnet Current for MAIN, Imag = 140.1012 A Vtrans = 1.400958 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:48:06 MAIN (V) Voltage Measurement, V = 22.019558 V 15:48:06 Temperature Measurement, Probe Number = 0, T = 24.030000 C 15:48:07 Temperature Measurement, Probe Number = 1, T = 30.138000 C 15:48:08 Temperature Measurement, Probe Number = 2, T = 20.509000 C 15:48:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325419 V 15:48:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325419 (V, A, ohm, ...), Measured Value = 28.408592 (C, atm, Hz, ...) 15:48:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.559304 V 15:48:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.559304 (V, A, ohm, ...), Measured Value = 31.657004 (C, atm, Hz, ...) 15:48:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652920 V 15:48:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652920 (V, A, ohm, ...), Measured Value = 123.969015 (C, atm, Hz, ...) 15:48:10 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106358 V 15:48:10 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106358 (V, A, ohm, ...), Measured Value = 7.976827 (C, atm, Hz, ...) 15:48:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 140.10 P1 = MAIN (V), Value = 22.02 P2 = Magnet Core, Value = 24.03 P3 = Coil, Value = 30.14 P4 = Ambient Temp (C), Value = 20.51 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 31.66 P7 = Supply Pres(psi), Value = 123.97 P8 = Return Pres(psi), Value = 7.98 15:48:10 Magnetic Field Measurement Measuring the magnet strength... 15:48:11 Integrated Voltage Measurement... 15:48:11 Magnet Current for MAIN, Imag = 140.1012 A Vtrans = 1.400958 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:48:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055353005 Vs 15:48:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055389804 Vs 15:48:27 Magnet Current for MAIN, Imag = 140.1008 A Vtrans = 1.400954 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:48:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055331203 Vs 15:48:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055368569 Vs 15:48:41 Magnet Current for MAIN, Imag = 140.1010 A Vtrans = 1.400955 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055333159 Vs 15:48:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055358041 Vs 15:48:56 Magnet Current for MAIN, Imag = 140.1006 A Vtrans = 1.400951 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:49:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055338265 Vs 15:49:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055348899 Vs 15:49:11 Magnet Current for MAIN, Imag = 140.1004 A Vtrans = 1.400950 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055336871 Vs 15:49:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.055348020 Vs 15:49:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.055350584 +- 0.000010715 Vs 15:49:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.055350584 +- 0.000010715 Vs BL = 0.61500649 +- 0.00011906 Tm 15:49:29 Position moved: 0.000000 m 15:49:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.61501 0.00012 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.61501 0.00012 0.61501 0.00000 15:49:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.61501 0.00012 SL = 0.6150065 +- 0.0001191 Tm^2/m^n 15:49:29 Magnet Strength Measurement Harmonic Number = 1 SL = 0.6150065 +- 0.0001191 Tm^2/m^n 15:49:31 Position moved: 0.000000 m 15:49:31 Magnet system MAIN current ramping to 120.0000 A... 15:49:48 Magnet Current for MAIN, Imag = 120.0536 A Vtrans = 1.200482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:49:49 MAIN (V) Voltage Measurement, V = 18.805329 V 15:49:49 Temperature Measurement, Probe Number = 0, T = 24.055000 C 15:49:50 Temperature Measurement, Probe Number = 1, T = 29.902000 C 15:49:51 Temperature Measurement, Probe Number = 2, T = 20.440000 C 15:49:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325150 V 15:49:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325150 (V, A, ohm, ...), Measured Value = 28.404867 (C, atm, Hz, ...) 15:49:52 Sensor Voltage Measurement, Sensor Number = 1, V = 2.580177 V 15:49:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.580177 (V, A, ohm, ...), Measured Value = 31.946897 (C, atm, Hz, ...) 15:49:53 Sensor Voltage Measurement, Sensor Number = 2, V = 2.663335 V 15:49:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663335 (V, A, ohm, ...), Measured Value = 124.750155 (C, atm, Hz, ...) 15:49:53 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106402 V 15:49:53 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106402 (V, A, ohm, ...), Measured Value = 7.980165 (C, atm, Hz, ...) 15:49:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.05 P1 = MAIN (V), Value = 18.81 P2 = Magnet Core, Value = 24.05 P3 = Coil, Value = 29.90 P4 = Ambient Temp (C), Value = 20.44 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 31.95 P7 = Supply Pres(psi), Value = 124.75 P8 = Return Pres(psi), Value = 7.98 15:49:53 Magnetic Field Measurement Measuring the magnet strength... 15:49:53 Integrated Voltage Measurement... 15:49:54 Magnet Current for MAIN, Imag = 120.0535 A Vtrans = 1.200481 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:50:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047539620 Vs 15:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047569815 Vs 15:50:10 Magnet Current for MAIN, Imag = 120.0534 A Vtrans = 1.200479 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:50:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047526363 Vs 15:50:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047558780 Vs 15:50:24 Magnet Current for MAIN, Imag = 120.0536 A Vtrans = 1.200482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:50:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047531839 Vs 15:50:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047549691 Vs 15:50:39 Magnet Current for MAIN, Imag = 120.0536 A Vtrans = 1.200482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:50:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047528917 Vs 15:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047543893 Vs 15:50:54 Magnet Current for MAIN, Imag = 120.0536 A Vtrans = 1.200482 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:51:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047528086 Vs 15:51:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.047532488 Vs 15:51:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.047540949 +- 0.000008082 Vs 15:51:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.047540949 +- 0.000008082 Vs BL = 0.52823277 +- 0.00008980 Tm 15:51:11 Position moved: 0.000000 m 15:51:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.52823 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.52823 0.00009 0.52823 0.00000 15:51:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.52823 0.00009 SL = 0.5282328 +- 0.0000898 Tm^2/m^n 15:51:12 Magnet Strength Measurement Harmonic Number = 1 SL = 0.5282328 +- 0.0000898 Tm^2/m^n 15:51:14 Position moved: 0.000000 m 15:51:15 Magnet system MAIN current ramping to 100.0000 A... 15:51:31 Magnet Current for MAIN, Imag = 100.0630 A Vtrans = 1.000576 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:51:32 MAIN (V) Voltage Measurement, V = 15.623623 V 15:51:32 Temperature Measurement, Probe Number = 0, T = 24.071000 C 15:51:33 Temperature Measurement, Probe Number = 1, T = 29.547000 C 15:51:34 Temperature Measurement, Probe Number = 2, T = 20.540000 C 15:51:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325267 V 15:51:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325267 (V, A, ohm, ...), Measured Value = 28.406490 (C, atm, Hz, ...) 15:51:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.583216 V 15:51:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.583216 (V, A, ohm, ...), Measured Value = 31.989107 (C, atm, Hz, ...) 15:51:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.657596 V 15:51:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657596 (V, A, ohm, ...), Measured Value = 124.319737 (C, atm, Hz, ...) 15:51:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106397 V 15:51:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106397 (V, A, ohm, ...), Measured Value = 7.979782 (C, atm, Hz, ...) 15:51:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 100.06 P1 = MAIN (V), Value = 15.62 P2 = Magnet Core, Value = 24.07 P3 = Coil, Value = 29.55 P4 = Ambient Temp (C), Value = 20.54 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 31.99 P7 = Supply Pres(psi), Value = 124.32 P8 = Return Pres(psi), Value = 7.98 15:51:36 Magnetic Field Measurement Measuring the magnet strength... 15:51:36 Integrated Voltage Measurement... 15:51:37 Magnet Current for MAIN, Imag = 100.0632 A Vtrans = 1.000578 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:51:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039699241 Vs 15:51:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039711896 Vs 15:51:53 Magnet Current for MAIN, Imag = 100.0631 A Vtrans = 1.000577 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:52:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039683711 Vs 15:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039701904 Vs 15:52:07 Magnet Current for MAIN, Imag = 100.0634 A Vtrans = 1.000579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:52:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039681983 Vs 15:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039691628 Vs 15:52:22 Magnet Current for MAIN, Imag = 100.0630 A Vtrans = 1.000575 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:52:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039679172 Vs 15:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039687615 Vs 15:52:37 Magnet Current for MAIN, Imag = 100.0630 A Vtrans = 1.000576 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:52:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039680481 Vs 15:52:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039685974 Vs 15:52:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039690361 +- 0.000008359 Vs 15:52:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.039690361 +- 0.000008359 Vs BL = 0.44100401 +- 0.00009287 Tm 15:52:54 Position moved: 0.000000 m 15:52:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.44100 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.44100 0.00009 0.44100 0.00000 15:52:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.44100 0.00009 SL = 0.4410040 +- 0.0000929 Tm^2/m^n 15:52:54 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4410040 +- 0.0000929 Tm^2/m^n Remeasure 15:52:55 Magnetic Field Measurement Measuring the magnet strength... 15:52:55 Integrated Voltage Measurement... 15:52:55 Magnet Current for MAIN, Imag = 100.0629 A Vtrans = 1.000574 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:53:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039677891 Vs 15:53:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039683968 Vs 15:53:11 Magnet Current for MAIN, Imag = 100.0631 A Vtrans = 1.000576 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:53:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039678953 Vs 15:53:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039684237 Vs 15:53:26 Magnet Current for MAIN, Imag = 100.0633 A Vtrans = 1.000579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:53:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039678537 Vs 15:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039679098 Vs 15:53:40 Magnet Current for MAIN, Imag = 100.0634 A Vtrans = 1.000579 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:53:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039676094 Vs 15:53:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039683185 Vs 15:53:55 Magnet Current for MAIN, Imag = 100.0630 A Vtrans = 1.000576 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:54:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039680041 Vs 15:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.039680994 Vs 15:54:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.039680300 +- 0.000000975 Vs 15:54:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.039680300 +- 0.000000975 Vs BL = 0.44089222 +- 0.00001083 Tm 15:54:13 Position moved: 0.000000 m 15:54:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.44089 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.44089 0.00001 0.44089 0.00000 15:54:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.44089 0.00001 SL = 0.4408922 +- 0.0000108 Tm^2/m^n 15:54:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.4408922 +- 0.0000108 Tm^2/m^n 15:54:16 Position moved: 0.000000 m 15:54:16 Magnet system MAIN current ramping to 80.0000 A... 15:54:32 Magnet Current for MAIN, Imag = 80.0108 A Vtrans = 0.800054 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:54:33 MAIN (V) Voltage Measurement, V = 12.446207 V 15:54:33 Temperature Measurement, Probe Number = 0, T = 24.097000 C 15:54:34 Temperature Measurement, Probe Number = 1, T = 28.944000 C 15:54:35 Temperature Measurement, Probe Number = 2, T = 20.520000 C 15:54:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325842 V 15:54:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325842 (V, A, ohm, ...), Measured Value = 28.414471 (C, atm, Hz, ...) 15:54:36 Sensor Voltage Measurement, Sensor Number = 1, V = 2.549908 V 15:54:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.549908 (V, A, ohm, ...), Measured Value = 31.526507 (C, atm, Hz, ...) 15:54:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.656196 V 15:54:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656196 (V, A, ohm, ...), Measured Value = 124.214678 (C, atm, Hz, ...) 15:54:37 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106518 V 15:54:37 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106518 (V, A, ohm, ...), Measured Value = 7.988835 (C, atm, Hz, ...) 15:54:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 80.01 P1 = MAIN (V), Value = 12.45 P2 = Magnet Core, Value = 24.10 P3 = Coil, Value = 28.94 P4 = Ambient Temp (C), Value = 20.52 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 31.53 P7 = Supply Pres(psi), Value = 124.21 P8 = Return Pres(psi), Value = 7.99 15:54:37 Magnetic Field Measurement Measuring the magnet strength... 15:54:38 Integrated Voltage Measurement... 15:54:38 Magnet Current for MAIN, Imag = 80.0109 A Vtrans = 0.800054 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:54:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031805347 Vs 15:54:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031803984 Vs 15:54:54 Magnet Current for MAIN, Imag = 80.0107 A Vtrans = 0.800053 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:55:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031788938 Vs 15:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031792992 Vs 15:55:08 Magnet Current for MAIN, Imag = 80.0110 A Vtrans = 0.800056 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031780621 Vs 15:55:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031786586 Vs 15:55:23 Magnet Current for MAIN, Imag = 80.0110 A Vtrans = 0.800056 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:55:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031778480 Vs 15:55:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031784734 Vs 15:55:38 Magnet Current for MAIN, Imag = 80.0110 A Vtrans = 0.800056 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:55:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031779269 Vs 15:55:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031783522 Vs 15:55:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031788447 +- 0.000008824 Vs 15:55:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.031788447 +- 0.000008824 Vs BL = 0.35320497 +- 0.00009805 Tm 15:55:55 Position moved: 0.000000 m 15:55:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.35320 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.35320 0.00010 0.35320 0.00000 15:55:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.35320 0.00010 SL = 0.3532050 +- 0.0000980 Tm^2/m^n 15:55:55 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3532050 +- 0.0000980 Tm^2/m^n Remeasure 15:55:55 Magnetic Field Measurement Measuring the magnet strength... 15:55:55 Integrated Voltage Measurement... 15:55:56 Magnet Current for MAIN, Imag = 80.0109 A Vtrans = 0.800054 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:56:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031774282 Vs 15:56:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031784957 Vs 15:56:12 Magnet Current for MAIN, Imag = 80.0107 A Vtrans = 0.800052 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:56:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031777601 Vs 15:56:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031781326 Vs 15:56:26 Magnet Current for MAIN, Imag = 80.0109 A Vtrans = 0.800054 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:56:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031778138 Vs 15:56:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031781316 Vs 15:56:41 Magnet Current for MAIN, Imag = 80.0107 A Vtrans = 0.800052 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:56:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031780375 Vs 15:56:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031778186 Vs 15:56:55 Magnet Current for MAIN, Imag = 80.0107 A Vtrans = 0.800052 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:57:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031778366 Vs 15:57:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.031777824 Vs 15:57:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.031779237 +- 0.000000591 Vs 15:57:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.031779237 +- 0.000000591 Vs BL = 0.35310264 +- 0.00000656 Tm 15:57:13 Position moved: 0.000000 m 15:57:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.35310 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.35310 0.00001 0.35310 0.00000 15:57:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.35310 0.00001 SL = 0.3531026 +- 0.0000066 Tm^2/m^n 15:57:13 Magnet Strength Measurement Harmonic Number = 1 SL = 0.3531026 +- 0.0000066 Tm^2/m^n 15:57:16 Position moved: 0.000000 m 15:57:16 Magnet system MAIN current ramping to 60.0000 A... 15:57:33 Magnet Current for MAIN, Imag = 60.0149 A Vtrans = 0.600095 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:57:33 MAIN (V) Voltage Measurement, V = 9.313058 V 15:57:34 Temperature Measurement, Probe Number = 0, T = 24.111000 C 15:57:35 Temperature Measurement, Probe Number = 1, T = 28.475000 C 15:57:35 Temperature Measurement, Probe Number = 2, T = 20.508000 C 15:57:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.326199 V 15:57:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.326199 (V, A, ohm, ...), Measured Value = 28.419431 (C, atm, Hz, ...) 15:57:37 Sensor Voltage Measurement, Sensor Number = 1, V = 2.494887 V 15:57:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.494887 (V, A, ohm, ...), Measured Value = 30.762322 (C, atm, Hz, ...) 15:57:37 Sensor Voltage Measurement, Sensor Number = 2, V = 2.658602 V 15:57:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658602 (V, A, ohm, ...), Measured Value = 124.395142 (C, atm, Hz, ...) 15:57:38 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106314 V 15:57:38 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106314 (V, A, ohm, ...), Measured Value = 7.973580 (C, atm, Hz, ...) 15:57:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 60.01 P1 = MAIN (V), Value = 9.31 P2 = Magnet Core, Value = 24.11 P3 = Coil, Value = 28.48 P4 = Ambient Temp (C), Value = 20.51 P5 = Supply Temp(C), Value = 28.42 P6 = Return Temp(C), Value = 30.76 P7 = Supply Pres(psi), Value = 124.40 P8 = Return Pres(psi), Value = 7.97 15:57:38 Magnetic Field Measurement Measuring the magnet strength... 15:57:38 Integrated Voltage Measurement... 15:57:39 Magnet Current for MAIN, Imag = 60.0151 A Vtrans = 0.600097 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:57:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023916253 Vs 15:57:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023909556 Vs 15:57:54 Magnet Current for MAIN, Imag = 60.0152 A Vtrans = 0.600098 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:58:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023900180 Vs 15:58:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023897339 Vs 15:58:09 Magnet Current for MAIN, Imag = 60.0151 A Vtrans = 0.600096 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:58:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023893815 Vs 15:58:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023894699 Vs 15:58:24 Magnet Current for MAIN, Imag = 60.0152 A Vtrans = 0.600098 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:58:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023890382 Vs 15:58:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023890950 Vs 15:58:38 Magnet Current for MAIN, Imag = 60.0150 A Vtrans = 0.600095 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:58:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023885104 Vs 15:58:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023889082 Vs 15:58:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023896736 +- 0.000008961 Vs 15:58:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.023896736 +- 0.000008961 Vs BL = 0.26551929 +- 0.00009956 Tm 15:58:56 Position moved: 0.000000 m 15:58:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.26552 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.26552 0.00010 0.26552 0.00000 15:58:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.26552 0.00010 SL = 0.2655193 +- 0.0000996 Tm^2/m^n 15:58:56 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2655193 +- 0.0000996 Tm^2/m^n Remeasure 15:58:56 Magnetic Field Measurement Measuring the magnet strength... 15:58:56 Integrated Voltage Measurement... 15:58:57 Magnet Current for MAIN, Imag = 60.0152 A Vtrans = 0.600098 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:59:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023884566 Vs 15:59:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023885670 Vs 15:59:13 Magnet Current for MAIN, Imag = 60.0148 A Vtrans = 0.600094 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023884986 Vs 15:59:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023887994 Vs 15:59:27 Magnet Current for MAIN, Imag = 60.0150 A Vtrans = 0.600095 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:59:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023883058 Vs 15:59:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023888452 Vs 15:59:42 Magnet Current for MAIN, Imag = 60.0149 A Vtrans = 0.600095 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 15:59:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023885226 Vs 15:59:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023885925 Vs 15:59:57 Magnet Current for MAIN, Imag = 60.0150 A Vtrans = 0.600096 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:00:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023883498 Vs 16:00:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.023885884 Vs 16:00:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.023885526 +- 0.000000608 Vs 16:00:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.023885526 +- 0.000000608 Vs BL = 0.26539473 +- 0.00000675 Tm 16:00:14 Position moved: 0.000000 m 16:00:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.26539 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.26539 0.00001 0.26539 0.00000 16:00:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.26539 0.00001 SL = 0.2653947 +- 0.0000068 Tm^2/m^n 16:00:14 Magnet Strength Measurement Harmonic Number = 1 SL = 0.2653947 +- 0.0000068 Tm^2/m^n 16:00:17 Position moved: 0.000000 m 16:00:17 Magnet system MAIN current ramping to 40.0000 A... 16:00:34 Magnet Current for MAIN, Imag = 39.9600 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:00:34 MAIN (V) Voltage Measurement, V = 6.189338 V 16:00:35 Temperature Measurement, Probe Number = 0, T = 24.116000 C 16:00:36 Temperature Measurement, Probe Number = 1, T = 28.151000 C 16:00:36 Temperature Measurement, Probe Number = 2, T = 20.529000 C 16:00:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325491 V 16:00:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325491 (V, A, ohm, ...), Measured Value = 28.409599 (C, atm, Hz, ...) 16:00:38 Sensor Voltage Measurement, Sensor Number = 1, V = 2.441338 V 16:00:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.441338 (V, A, ohm, ...), Measured Value = 30.018586 (C, atm, Hz, ...) 16:00:38 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655839 V 16:00:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655839 (V, A, ohm, ...), Measured Value = 124.187895 (C, atm, Hz, ...) 16:00:39 Sensor Voltage Measurement, Sensor Number = 3, V = 1.106196 V 16:00:39 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.106196 (V, A, ohm, ...), Measured Value = 7.964715 (C, atm, Hz, ...) 16:00:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 39.96 P1 = MAIN (V), Value = 6.19 P2 = Magnet Core, Value = 24.12 P3 = Coil, Value = 28.15 P4 = Ambient Temp (C), Value = 20.53 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 30.02 P7 = Supply Pres(psi), Value = 124.19 P8 = Return Pres(psi), Value = 7.96 16:00:39 Magnetic Field Measurement Measuring the magnet strength... 16:00:39 Integrated Voltage Measurement... 16:00:40 Magnet Current for MAIN, Imag = 39.9599 A Vtrans = 0.399545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:00:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015996582 Vs 16:00:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015982673 Vs 16:00:56 Magnet Current for MAIN, Imag = 39.9601 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:01:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015977720 Vs 16:01:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015972062 Vs 16:01:10 Magnet Current for MAIN, Imag = 39.9601 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:01:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015967554 Vs 16:01:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015967127 Vs 16:01:25 Magnet Current for MAIN, Imag = 39.9603 A Vtrans = 0.399548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:01:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015961429 Vs 16:01:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015963919 Vs 16:01:39 Magnet Current for MAIN, Imag = 39.9604 A Vtrans = 0.399549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:01:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015959990 Vs 16:01:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015963220 Vs 16:01:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015971227 +- 0.000010323 Vs 16:01:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.015971227 +- 0.000010323 Vs BL = 0.17745808 +- 0.00011470 Tm 16:01:57 Position moved: 0.000000 m 16:01:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.17746 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.17746 0.00011 0.17746 0.00000 16:01:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.17746 0.00011 SL = 0.1774581 +- 0.0001147 Tm^2/m^n 16:01:57 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1774581 +- 0.0001147 Tm^2/m^n Remeasure 16:01:57 Magnetic Field Measurement Measuring the magnet strength... 16:01:57 Integrated Voltage Measurement... 16:01:58 Magnet Current for MAIN, Imag = 39.9602 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:02:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015956603 Vs 16:02:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015961037 Vs 16:02:14 Magnet Current for MAIN, Imag = 39.9600 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:02:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015956619 Vs 16:02:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015959768 Vs 16:02:28 Magnet Current for MAIN, Imag = 39.9601 A Vtrans = 0.399546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:02:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015955051 Vs 16:02:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015961288 Vs 16:02:43 Magnet Current for MAIN, Imag = 39.9602 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:02:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015957927 Vs 16:02:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015958458 Vs 16:02:57 Magnet Current for MAIN, Imag = 39.9601 A Vtrans = 0.399547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015957107 Vs 16:03:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.015958647 Vs 16:03:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.015958251 +- 0.000000309 Vs 16:03:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.015958251 +- 0.000000309 Vs BL = 0.17731390 +- 0.00000343 Tm 16:03:15 Position moved: 0.000000 m 16:03:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.17731 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.17731 0.00000 0.17731 0.00000 16:03:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.17731 0.00000 SL = 0.1773139 +- 0.0000034 Tm^2/m^n 16:03:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1773139 +- 0.0000034 Tm^2/m^n 16:03:18 Position moved: 0.000000 m 16:03:18 Magnet system MAIN current ramping to 20.0000 A... 16:03:35 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:03:35 MAIN (V) Voltage Measurement, V = 3.088611 V 16:03:36 Temperature Measurement, Probe Number = 0, T = 24.122000 C 16:03:37 Temperature Measurement, Probe Number = 1, T = 27.889000 C 16:03:37 Temperature Measurement, Probe Number = 2, T = 20.545000 C 16:03:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325073 V 16:03:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325073 (V, A, ohm, ...), Measured Value = 28.403790 (C, atm, Hz, ...) 16:03:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.395462 V 16:03:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.395462 (V, A, ohm, ...), Measured Value = 29.381422 (C, atm, Hz, ...) 16:03:39 Sensor Voltage Measurement, Sensor Number = 2, V = 2.652456 V 16:03:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652456 (V, A, ohm, ...), Measured Value = 123.934222 (C, atm, Hz, ...) 16:03:40 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105989 V 16:03:40 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105989 (V, A, ohm, ...), Measured Value = 7.949182 (C, atm, Hz, ...) 16:03:40 Magnet Test Parameter Measurements P0 = MAIN, Value = 19.98 P1 = MAIN (V), Value = 3.09 P2 = Magnet Core, Value = 24.12 P3 = Coil, Value = 27.89 P4 = Ambient Temp (C), Value = 20.55 P5 = Supply Temp(C), Value = 28.40 P6 = Return Temp(C), Value = 29.38 P7 = Supply Pres(psi), Value = 123.93 P8 = Return Pres(psi), Value = 7.95 16:03:40 Magnetic Field Measurement Measuring the magnet strength... 16:03:40 Integrated Voltage Measurement... 16:03:41 Magnet Current for MAIN, Imag = 19.9753 A Vtrans = 0.199698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:03:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008095979 Vs 16:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008074991 Vs 16:03:57 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008072066 Vs 16:04:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008065075 Vs 16:04:11 Magnet Current for MAIN, Imag = 19.9754 A Vtrans = 0.199699 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:04:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008060820 Vs 16:04:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008060186 Vs 16:04:26 Magnet Current for MAIN, Imag = 19.9752 A Vtrans = 0.199697 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:04:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008054912 Vs 16:04:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008057186 Vs 16:04:40 Magnet Current for MAIN, Imag = 19.9750 A Vtrans = 0.199696 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:04:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008052398 Vs 16:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008054588 Vs 16:04:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008064820 +- 0.000011532 Vs 16:04:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.008064820 +- 0.000011532 Vs BL = 0.08960911 +- 0.00012814 Tm 16:04:58 Position moved: 0.000000 m 16:04:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.08961 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.08961 0.00013 0.08961 0.00000 16:04:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.08961 0.00013 SL = 0.0896091 +- 0.0001281 Tm^2/m^n 16:04:58 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0896091 +- 0.0001281 Tm^2/m^n Remeasure 16:04:58 Magnetic Field Measurement Measuring the magnet strength... 16:04:58 Integrated Voltage Measurement... 16:04:59 Magnet Current for MAIN, Imag = 19.9748 A Vtrans = 0.199694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:05:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008049772 Vs 16:05:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008053063 Vs 16:05:15 Magnet Current for MAIN, Imag = 19.9748 A Vtrans = 0.199693 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:05:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008049306 Vs 16:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008052366 Vs 16:05:29 Magnet Current for MAIN, Imag = 19.9748 A Vtrans = 0.199693 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:05:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008048790 Vs 16:05:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008052083 Vs 16:05:44 Magnet Current for MAIN, Imag = 19.9748 A Vtrans = 0.199694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008049612 Vs 16:05:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008051881 Vs 16:05:58 Magnet Current for MAIN, Imag = 19.9749 A Vtrans = 0.199694 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:06:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008048836 Vs 16:06:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.008051963 Vs 16:06:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.008050767 +- 0.000000367 Vs 16:06:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.008050767 +- 0.000000367 Vs BL = 0.08945297 +- 0.00000407 Tm 16:06:16 Position moved: 0.000000 m 16:06:16 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.08945 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.08945 0.00000 0.08945 0.00000 16:06:16 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.08945 0.00000 SL = 0.0894530 +- 0.0000041 Tm^2/m^n 16:06:16 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0894530 +- 0.0000041 Tm^2/m^n 16:06:19 Position moved: 0.000000 m 16:06:19 Magnet system MAIN current ramping to 0.0000 A... 16:06:35 Magnet Current for MAIN, Imag = 0.0018 A Vtrans = -0.000037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:06:36 MAIN (V) Voltage Measurement, V = -0.003072 V 16:06:37 Temperature Measurement, Probe Number = 0, T = 24.125000 C 16:06:37 Temperature Measurement, Probe Number = 1, T = 27.707000 C 16:06:38 Temperature Measurement, Probe Number = 2, T = 20.535000 C 16:06:39 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325302 V 16:06:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325302 (V, A, ohm, ...), Measured Value = 28.406968 (C, atm, Hz, ...) 16:06:39 Sensor Voltage Measurement, Sensor Number = 1, V = 2.358097 V 16:06:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.358097 (V, A, ohm, ...), Measured Value = 28.862453 (C, atm, Hz, ...) 16:06:40 Sensor Voltage Measurement, Sensor Number = 2, V = 2.655314 V 16:06:40 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655314 (V, A, ohm, ...), Measured Value = 124.148520 (C, atm, Hz, ...) 16:06:41 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105556 V 16:06:41 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105556 (V, A, ohm, ...), Measured Value = 7.916670 (C, atm, Hz, ...) 16:06:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = MAIN (V), Value = -0.00 P2 = Magnet Core, Value = 24.12 P3 = Coil, Value = 27.71 P4 = Ambient Temp (C), Value = 20.54 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 28.86 P7 = Supply Pres(psi), Value = 124.15 P8 = Return Pres(psi), Value = 7.92 16:06:41 Magnetic Field Measurement Measuring the magnet strength... 16:06:41 Integrated Voltage Measurement... 16:06:42 Magnet Current for MAIN, Imag = 0.0014 A Vtrans = -0.000041 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:06:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000185140 Vs 16:06:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000164583 Vs 16:06:57 Magnet Current for MAIN, Imag = 0.0008 A Vtrans = -0.000046 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:07:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000157489 Vs 16:07:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000152701 Vs 16:07:12 Magnet Current for MAIN, Imag = 0.0004 A Vtrans = -0.000051 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:07:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000145579 Vs 16:07:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000146506 Vs 16:07:26 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = -0.000052 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:07:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000139377 Vs 16:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000142867 Vs 16:07:41 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000053 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:07:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000135216 Vs 16:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0090000 m VT = -0.000141131 Vs 16:07:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0090000 m VT = 0.000151059 +- 0.000013212 Vs 16:07:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0090000 m, Nturns = 10.0 VT = 0.000151059 +- 0.000013212 Vs BL = 0.00167843 +- 0.00014680 Tm 16:07:59 Position moved: 0.000000 m 16:07:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00168 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00168 0.00015 0.00168 0.00000 16:07:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00168 0.00015 SL = 0.0016784 +- 0.0001468 Tm^2/m^n 16:07:59 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0016784 +- 0.0001468 Tm^2/m^n 16:08:02 Position moved: 0.000000 m 16:08:02 Magnet system MAIN current ramping to 200.0000 A... 16:09:09 Magnet Current for MAIN, Imag = 200.1482 A Vtrans = 2.001428 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:09:09 MAIN (V) Voltage Measurement, V = 31.189329 V 16:09:10 Temperature Measurement, Probe Number = 0, T = 24.127000 C 16:09:11 Temperature Measurement, Probe Number = 1, T = 27.704000 C 16:09:11 Temperature Measurement, Probe Number = 2, T = 20.542000 C 16:09:12 Sensor Voltage Measurement, Sensor Number = 0, V = 2.325206 V 16:09:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.325206 (V, A, ohm, ...), Measured Value = 28.405643 (C, atm, Hz, ...) 16:09:12 Sensor Voltage Measurement, Sensor Number = 1, V = 2.333473 V 16:09:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.333473 (V, A, ohm, ...), Measured Value = 28.520464 (C, atm, Hz, ...) 16:09:13 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664437 V 16:09:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664437 (V, A, ohm, ...), Measured Value = 124.832805 (C, atm, Hz, ...) 16:09:14 Sensor Voltage Measurement, Sensor Number = 3, V = 1.105524 V 16:09:14 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.105524 (V, A, ohm, ...), Measured Value = 7.914285 (C, atm, Hz, ...) 16:09:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 200.15 P1 = MAIN (V), Value = 31.19 P2 = Magnet Core, Value = 24.13 P3 = Coil, Value = 27.70 P4 = Ambient Temp (C), Value = 20.54 P5 = Supply Temp(C), Value = 28.41 P6 = Return Temp(C), Value = 28.52 P7 = Supply Pres(psi), Value = 124.83 P8 = Return Pres(psi), Value = 7.91 16:09:14 Integrated Voltage Measurement... 16:09:15 Magnet Current for MAIN, Imag = 200.1482 A Vtrans = 2.001428 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:09:24 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025568451 Vs 16:09:30 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = -0.025571633 Vs 16:09:31 Magnet Current for MAIN, Imag = 200.1485 A Vtrans = 2.001430 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:09:38 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025570299 Vs 16:09:45 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = -0.025573143 Vs 16:09:46 Magnet Current for MAIN, Imag = 200.1482 A Vtrans = 2.001428 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:09:52 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025565691 Vs 16:09:59 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = -0.025564279 Vs 16:10:00 Magnet Current for MAIN, Imag = 200.1485 A Vtrans = 2.001430 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:10:07 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025570807 Vs 16:10:14 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = -0.025563151 Vs 16:10:15 Magnet Current for MAIN, Imag = 200.1484 A Vtrans = 2.001429 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:10:22 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025570466 Vs 16:10:29 Integrated Voltage Measurement X0 = -0.0450000 m, Delta X = -0.0030000 m VT = -0.025564764 Vs 16:10:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0450000 m, Delta X = 0.0030000 m VT = 0.025568268 +- 0.000002364 Vs 16:10:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0450000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025568268 +- 0.000002364 Vs BL = 0.85227562 +- 0.00007879 Tm 16:10:29 Integrated Voltage Measurement... 16:10:30 Magnet Current for MAIN, Imag = 200.1486 A Vtrans = 2.001431 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:10:38 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025559137 Vs 16:10:44 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = -0.025551464 Vs 16:10:45 Magnet Current for MAIN, Imag = 200.1494 A Vtrans = 2.001439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:10:52 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025542231 Vs 16:10:59 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = -0.025542282 Vs 16:11:00 Magnet Current for MAIN, Imag = 200.1490 A Vtrans = 2.001435 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:11:07 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025543195 Vs 16:11:14 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = -0.025544963 Vs 16:11:14 Magnet Current for MAIN, Imag = 200.1494 A Vtrans = 2.001439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:11:21 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025540037 Vs 16:11:28 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = -0.025554145 Vs 16:11:29 Magnet Current for MAIN, Imag = 200.1491 A Vtrans = 2.001437 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:11:36 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025545994 Vs 16:11:43 Integrated Voltage Measurement X0 = -0.0420000 m, Delta X = -0.0030000 m VT = -0.025546795 Vs 16:11:43 Integrated Voltage Average and RMS of Measurements X0 = -0.0420000 m, Delta X = 0.0030000 m VT = 0.025547024 +- 0.000004479 Vs 16:11:43 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0420000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025547024 +- 0.000004479 Vs BL = 0.85156748 +- 0.00014930 Tm 16:11:43 Integrated Voltage Measurement... 16:11:44 Magnet Current for MAIN, Imag = 200.1495 A Vtrans = 2.001440 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:11:52 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025540010 Vs 16:11:59 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = -0.025546989 Vs 16:11:59 Magnet Current for MAIN, Imag = 200.1494 A Vtrans = 2.001439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:12:06 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025535538 Vs 16:12:13 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = -0.025536972 Vs 16:12:14 Magnet Current for MAIN, Imag = 200.1495 A Vtrans = 2.001440 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:12:21 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025531708 Vs 16:12:28 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = -0.025534023 Vs 16:12:28 Magnet Current for MAIN, Imag = 200.1496 A Vtrans = 2.001442 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:12:35 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025538331 Vs 16:12:42 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = -0.025537903 Vs 16:12:43 Magnet Current for MAIN, Imag = 200.1494 A Vtrans = 2.001439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:12:50 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025536949 Vs 16:12:57 Integrated Voltage Measurement X0 = -0.0390000 m, Delta X = -0.0030000 m VT = -0.025535899 Vs 16:12:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0390000 m, Delta X = 0.0030000 m VT = 0.025537432 +- 0.000003480 Vs 16:12:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0390000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025537432 +- 0.000003480 Vs BL = 0.85124774 +- 0.00011598 Tm 16:12:57 Integrated Voltage Measurement... 16:12:58 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:13:06 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025513271 Vs 16:13:13 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = -0.025536017 Vs 16:13:13 Magnet Current for MAIN, Imag = 200.1500 A Vtrans = 2.001445 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:13:20 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025533637 Vs 16:13:27 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = -0.025538482 Vs 16:13:28 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:13:35 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025527150 Vs 16:13:42 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = -0.025533316 Vs 16:13:42 Magnet Current for MAIN, Imag = 200.1500 A Vtrans = 2.001445 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:13:49 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025530815 Vs 16:13:56 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = -0.025533732 Vs 16:13:57 Magnet Current for MAIN, Imag = 200.1500 A Vtrans = 2.001445 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:14:04 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025536607 Vs 16:14:11 Integrated Voltage Measurement X0 = -0.0360000 m, Delta X = -0.0030000 m VT = -0.025535407 Vs 16:14:11 Integrated Voltage Average and RMS of Measurements X0 = -0.0360000 m, Delta X = 0.0030000 m VT = 0.025531843 +- 0.000004236 Vs 16:14:11 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0360000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025531843 +- 0.000004236 Vs BL = 0.85106145 +- 0.00014121 Tm 16:14:11 Integrated Voltage Measurement... 16:14:12 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:14:20 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025546493 Vs 16:14:27 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = -0.025528158 Vs 16:14:27 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:14:34 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025526214 Vs 16:14:41 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = -0.025535545 Vs 16:14:42 Magnet Current for MAIN, Imag = 200.1496 A Vtrans = 2.001442 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:14:49 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025532807 Vs 16:14:56 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = -0.025541439 Vs 16:14:56 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:15:03 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025526187 Vs 16:15:10 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = -0.025535887 Vs 16:15:11 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:15:18 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025529448 Vs 16:15:25 Integrated Voltage Measurement X0 = -0.0330000 m, Delta X = -0.0030000 m VT = -0.025528439 Vs 16:15:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0330000 m, Delta X = 0.0030000 m VT = 0.025533062 +- 0.000003479 Vs 16:15:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0330000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025533062 +- 0.000003479 Vs BL = 0.85110206 +- 0.00011595 Tm 16:15:25 Integrated Voltage Measurement... 16:15:26 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:15:34 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025555076 Vs 16:15:41 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025538933 Vs 16:15:41 Magnet Current for MAIN, Imag = 200.1499 A Vtrans = 2.001444 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:15:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025536818 Vs 16:15:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025542719 Vs 16:15:56 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:16:03 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025535074 Vs 16:16:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025522525 Vs 16:16:10 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:16:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025542695 Vs 16:16:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025533649 Vs 16:16:25 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:16:32 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025534258 Vs 16:16:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025524768 Vs 16:16:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025536651 +- 0.000006809 Vs 16:16:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025536651 +- 0.000006809 Vs BL = 0.85122171 +- 0.00022697 Tm Remeasure 16:16:39 Integrated Voltage Measurement... 16:16:39 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:16:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025535821 Vs 16:16:53 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025534064 Vs 16:16:54 Magnet Current for MAIN, Imag = 200.1500 A Vtrans = 2.001445 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:17:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025536507 Vs 16:17:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025528407 Vs 16:17:08 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:17:15 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025526285 Vs 16:17:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025533354 Vs 16:17:23 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:17:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025540245 Vs 16:17:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025527896 Vs 16:17:37 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:17:44 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025532442 Vs 16:17:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0030000 m VT = -0.025539991 Vs 16:17:51 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0030000 m VT = 0.025533501 +- 0.000002210 Vs 16:17:51 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025533501 +- 0.000002210 Vs BL = 0.85111671 +- 0.00007367 Tm 16:17:51 Integrated Voltage Measurement... 16:17:52 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:18:00 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025539609 Vs 16:18:07 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = -0.025533407 Vs 16:18:08 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:18:15 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025537227 Vs 16:18:21 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = -0.025532135 Vs 16:18:22 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:18:29 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025539037 Vs 16:18:36 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = -0.025542403 Vs 16:18:37 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:18:44 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025535573 Vs 16:18:50 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = -0.025531958 Vs 16:18:51 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:18:58 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025531414 Vs 16:19:05 Integrated Voltage Measurement X0 = -0.0270000 m, Delta X = -0.0030000 m VT = -0.025543137 Vs 16:19:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0270000 m, Delta X = 0.0030000 m VT = 0.025536590 +- 0.000002415 Vs 16:19:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0270000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025536590 +- 0.000002415 Vs BL = 0.85121966 +- 0.00008049 Tm 16:19:05 Integrated Voltage Measurement... 16:19:06 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:19:14 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025531207 Vs 16:19:21 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025525530 Vs 16:19:22 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:19:29 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025534030 Vs 16:19:36 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025546697 Vs 16:19:36 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:19:43 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025533505 Vs 16:19:50 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025537212 Vs 16:19:51 Magnet Current for MAIN, Imag = 200.1500 A Vtrans = 2.001445 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:19:58 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025542281 Vs 16:20:05 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025549711 Vs 16:20:05 Magnet Current for MAIN, Imag = 200.1498 A Vtrans = 2.001443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:20:12 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025533633 Vs 16:20:19 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025546809 Vs 16:20:19 Integrated Voltage Average and RMS of Measurements X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025538062 +- 0.000005902 Vs 16:20:19 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025538062 +- 0.000005902 Vs BL = 0.85126872 +- 0.00019674 Tm Remeasure 16:20:19 Integrated Voltage Measurement... 16:20:20 Magnet Current for MAIN, Imag = 200.1499 A Vtrans = 2.001444 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:20:27 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025542546 Vs 16:20:34 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025537651 Vs 16:20:35 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:20:42 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025547559 Vs 16:20:49 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025531265 Vs 16:20:49 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:20:56 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025534282 Vs 16:21:03 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025532709 Vs 16:21:04 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:21:11 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025533621 Vs 16:21:18 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025542269 Vs 16:21:18 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:21:25 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025538616 Vs 16:21:32 Integrated Voltage Measurement X0 = -0.0240000 m, Delta X = -0.0030000 m VT = -0.025532689 Vs 16:21:32 Integrated Voltage Average and RMS of Measurements X0 = -0.0240000 m, Delta X = 0.0030000 m VT = 0.025537321 +- 0.000002445 Vs 16:21:32 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025537321 +- 0.000002445 Vs BL = 0.85124402 +- 0.00008151 Tm 16:21:33 Integrated Voltage Measurement... 16:21:33 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:21:41 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025537772 Vs 16:21:48 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = -0.025545857 Vs 16:21:49 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:21:56 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025536264 Vs 16:22:03 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = -0.025542559 Vs 16:22:03 Magnet Current for MAIN, Imag = 200.1504 A Vtrans = 2.001449 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:22:10 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025547567 Vs 16:22:17 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = -0.025545223 Vs 16:22:18 Magnet Current for MAIN, Imag = 200.1503 A Vtrans = 2.001448 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:22:25 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025544266 Vs 16:22:32 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = -0.025537279 Vs 16:22:32 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:22:39 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025543622 Vs 16:22:46 Integrated Voltage Measurement X0 = -0.0210000 m, Delta X = -0.0030000 m VT = -0.025533166 Vs 16:22:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0210000 m, Delta X = 0.0030000 m VT = 0.025541357 +- 0.000002775 Vs 16:22:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0210000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025541357 +- 0.000002775 Vs BL = 0.85137858 +- 0.00009249 Tm 16:22:46 Integrated Voltage Measurement... 16:22:47 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:22:55 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025566048 Vs 16:23:02 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = -0.025549453 Vs 16:23:03 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:23:10 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025549888 Vs 16:23:17 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = -0.025541725 Vs 16:23:17 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:23:24 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025543941 Vs 16:23:31 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = -0.025550240 Vs 16:23:32 Magnet Current for MAIN, Imag = 200.1501 A Vtrans = 2.001447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:23:39 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025545887 Vs 16:23:46 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = -0.025542868 Vs 16:23:47 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:23:53 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025543897 Vs 16:24:00 Integrated Voltage Measurement X0 = -0.0180000 m, Delta X = -0.0030000 m VT = -0.025548453 Vs 16:24:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0180000 m, Delta X = 0.0030000 m VT = 0.025548240 +- 0.000004835 Vs 16:24:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025548240 +- 0.000004835 Vs BL = 0.85160800 +- 0.00016116 Tm 16:24:01 Integrated Voltage Measurement... 16:24:01 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:24:09 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025543998 Vs 16:24:16 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = -0.025537156 Vs 16:24:17 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:24:24 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025547438 Vs 16:24:31 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = -0.025552060 Vs 16:24:32 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:24:39 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025542012 Vs 16:24:45 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = -0.025545487 Vs 16:24:46 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:24:53 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025545777 Vs 16:25:00 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = -0.025543012 Vs 16:25:01 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:25:08 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025547436 Vs 16:25:15 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0030000 m VT = -0.025550892 Vs 16:25:15 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0030000 m VT = 0.025545527 +- 0.000003464 Vs 16:25:15 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025545527 +- 0.000003464 Vs BL = 0.85151756 +- 0.00011547 Tm 16:25:15 Integrated Voltage Measurement... 16:25:16 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:25:24 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025540915 Vs 16:25:30 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = -0.025558966 Vs 16:25:31 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:25:38 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025537783 Vs 16:25:45 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = -0.025542738 Vs 16:25:46 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:25:52 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025542530 Vs 16:25:59 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = -0.025538823 Vs 16:26:00 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:26:07 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025547512 Vs 16:26:14 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = -0.025541535 Vs 16:26:15 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:26:22 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025545734 Vs 16:26:28 Integrated Voltage Measurement X0 = -0.0120000 m, Delta X = -0.0030000 m VT = -0.025541057 Vs 16:26:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0120000 m, Delta X = 0.0030000 m VT = 0.025543759 +- 0.000003483 Vs 16:26:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0120000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025543759 +- 0.000003483 Vs BL = 0.85145864 +- 0.00011611 Tm 16:26:28 Integrated Voltage Measurement... 16:26:29 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:26:37 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025542463 Vs 16:26:44 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = -0.025552783 Vs 16:26:45 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:26:52 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025550195 Vs 16:26:59 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = -0.025544943 Vs 16:26:59 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:27:06 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025556079 Vs 16:27:13 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = -0.025548034 Vs 16:27:14 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:27:21 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025553069 Vs 16:27:28 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = -0.025548437 Vs 16:27:28 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:27:35 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025551664 Vs 16:27:42 Integrated Voltage Measurement X0 = -0.0090000 m, Delta X = -0.0030000 m VT = -0.025541329 Vs 16:27:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0090000 m, Delta X = 0.0030000 m VT = 0.025548900 +- 0.000002125 Vs 16:27:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0090000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025548900 +- 0.000002125 Vs BL = 0.85162999 +- 0.00007082 Tm 16:27:42 Integrated Voltage Measurement... 16:27:43 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:27:51 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025553953 Vs 16:27:58 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = -0.025539247 Vs 16:27:58 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:28:05 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025546554 Vs 16:28:12 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = -0.025563034 Vs 16:28:13 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:28:20 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025562351 Vs 16:28:27 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = -0.025543160 Vs 16:28:28 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:28:35 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025547684 Vs 16:28:42 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = -0.025564805 Vs 16:28:42 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:28:49 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025550679 Vs 16:28:56 Integrated Voltage Measurement X0 = -0.0060000 m, Delta X = -0.0030000 m VT = -0.025545003 Vs 16:28:56 Integrated Voltage Average and RMS of Measurements X0 = -0.0060000 m, Delta X = 0.0030000 m VT = 0.025551647 +- 0.000003801 Vs 16:28:56 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0060000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025551647 +- 0.000003801 Vs BL = 0.85172157 +- 0.00012669 Tm 16:28:56 Integrated Voltage Measurement... 16:28:57 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:29:05 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025549930 Vs 16:29:12 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = -0.025561295 Vs 16:29:13 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:29:20 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025556847 Vs 16:29:27 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = -0.025548034 Vs 16:29:28 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:29:34 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025558834 Vs 16:29:41 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = -0.025559492 Vs 16:29:42 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:29:49 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025549526 Vs 16:29:56 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = -0.025558260 Vs 16:29:57 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:30:03 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025554215 Vs 16:30:10 Integrated Voltage Measurement X0 = -0.0030000 m, Delta X = -0.0030000 m VT = -0.025548387 Vs 16:30:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0030000 m, Delta X = 0.0030000 m VT = 0.025554482 +- 0.000002750 Vs 16:30:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0030000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025554482 +- 0.000002750 Vs BL = 0.85181607 +- 0.00009168 Tm 16:30:11 Integrated Voltage Measurement... 16:30:11 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:30:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025568213 Vs 16:30:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025559727 Vs 16:30:27 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025542361 Vs 16:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025553199 Vs 16:30:42 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:30:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025553263 Vs 16:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025548874 Vs 16:30:56 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:31:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025554284 Vs 16:31:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025553321 Vs 16:31:11 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:31:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025560792 Vs 16:31:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025547257 Vs 16:31:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025554129 +- 0.000005416 Vs 16:31:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025554129 +- 0.000005416 Vs BL = 0.85180431 +- 0.00018052 Tm Remeasure 16:31:25 Integrated Voltage Measurement... 16:31:25 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025545094 Vs 16:31:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025556300 Vs 16:31:40 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:31:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025546113 Vs 16:31:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025551713 Vs 16:31:55 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:32:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025549249 Vs 16:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025553697 Vs 16:32:09 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025553845 Vs 16:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025546941 Vs 16:32:24 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025551102 Vs 16:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0030000 m VT = -0.025546946 Vs 16:32:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0030000 m VT = 0.025550100 +- 0.000000989 Vs 16:32:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025550100 +- 0.000000989 Vs BL = 0.85167000 +- 0.00003298 Tm 16:32:37 Integrated Voltage Measurement... 16:32:38 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:32:46 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025560113 Vs 16:32:53 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025568915 Vs 16:32:54 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:33:01 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025552057 Vs 16:33:08 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025544244 Vs 16:33:08 Magnet Current for MAIN, Imag = 200.1505 A Vtrans = 2.001451 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:33:15 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025553917 Vs 16:33:22 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025539279 Vs 16:33:23 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:33:30 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025563458 Vs 16:33:37 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025546629 Vs 16:33:38 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:33:44 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025554096 Vs 16:33:51 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025555870 Vs 16:33:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025553858 +- 0.000006348 Vs 16:33:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025553858 +- 0.000006348 Vs BL = 0.85179526 +- 0.00021161 Tm Remeasure 16:33:51 Integrated Voltage Measurement... 16:33:52 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:33:59 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025554625 Vs 16:34:06 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025548190 Vs 16:34:07 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:34:14 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025549542 Vs 16:34:21 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025546657 Vs 16:34:21 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:34:28 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025553367 Vs 16:34:35 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025547675 Vs 16:34:36 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:34:43 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025549076 Vs 16:34:50 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025542277 Vs 16:34:50 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:34:57 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025555189 Vs 16:35:04 Integrated Voltage Measurement X0 = 0.0030000 m, Delta X = -0.0030000 m VT = -0.025556660 Vs 16:35:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0030000 m, Delta X = 0.0030000 m VT = 0.025550326 +- 0.000003439 Vs 16:35:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0030000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025550326 +- 0.000003439 Vs BL = 0.85167753 +- 0.00011463 Tm 16:35:04 Integrated Voltage Measurement... 16:35:05 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:35:13 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025556427 Vs 16:35:20 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = -0.025555467 Vs 16:35:21 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:35:28 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025556359 Vs 16:35:34 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = -0.025558177 Vs 16:35:35 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:35:42 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025563868 Vs 16:35:49 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = -0.025549632 Vs 16:35:50 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:35:56 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025560631 Vs 16:36:03 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = -0.025556945 Vs 16:36:04 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:36:11 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025556052 Vs 16:36:18 Integrated Voltage Measurement X0 = 0.0060000 m, Delta X = -0.0030000 m VT = -0.025547690 Vs 16:36:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0060000 m, Delta X = 0.0030000 m VT = 0.025556125 +- 0.000002320 Vs 16:36:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0060000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025556125 +- 0.000002320 Vs BL = 0.85187082 +- 0.00007734 Tm 16:36:18 Integrated Voltage Measurement... 16:36:19 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:36:27 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025555206 Vs 16:36:34 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = -0.025549121 Vs 16:36:34 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:36:41 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025552073 Vs 16:36:48 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = -0.025544961 Vs 16:36:49 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:36:56 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025542434 Vs 16:37:03 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = -0.025545192 Vs 16:37:03 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:37:10 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025552905 Vs 16:37:17 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = -0.025554832 Vs 16:37:18 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:37:25 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025549874 Vs 16:37:32 Integrated Voltage Measurement X0 = 0.0090000 m, Delta X = -0.0030000 m VT = -0.025545214 Vs 16:37:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0090000 m, Delta X = 0.0030000 m VT = 0.025549181 +- 0.000003544 Vs 16:37:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0090000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025549181 +- 0.000003544 Vs BL = 0.85163937 +- 0.00011813 Tm 16:37:32 Integrated Voltage Measurement... 16:37:32 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:37:41 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025553624 Vs 16:37:47 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = -0.025540342 Vs 16:37:48 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:37:55 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025556731 Vs 16:38:02 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = -0.025534967 Vs 16:38:02 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:38:09 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025548453 Vs 16:38:16 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = -0.025559419 Vs 16:38:17 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:38:24 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025549308 Vs 16:38:31 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = -0.025562622 Vs 16:38:31 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:38:38 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025553340 Vs 16:38:45 Integrated Voltage Measurement X0 = 0.0120000 m, Delta X = -0.0030000 m VT = -0.025554517 Vs 16:38:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0120000 m, Delta X = 0.0030000 m VT = 0.025551332 +- 0.000004098 Vs 16:38:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0120000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025551332 +- 0.000004098 Vs BL = 0.85171108 +- 0.00013660 Tm 16:38:45 Integrated Voltage Measurement... 16:38:46 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:38:54 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025533913 Vs 16:39:01 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = -0.025545900 Vs 16:39:02 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:39:09 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025558967 Vs 16:39:15 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = -0.025545900 Vs 16:39:16 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:39:23 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025550885 Vs 16:39:30 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = -0.025550869 Vs 16:39:31 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:39:38 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025552063 Vs 16:39:44 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = -0.025545177 Vs 16:39:45 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:39:52 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025543453 Vs 16:39:59 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0030000 m VT = -0.025548036 Vs 16:39:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0030000 m VT = 0.025547516 +- 0.000004421 Vs 16:39:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025547516 +- 0.000004421 Vs BL = 0.85158388 +- 0.00014738 Tm 16:39:59 Integrated Voltage Measurement... 16:40:00 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:40:08 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025566922 Vs 16:40:15 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025543874 Vs 16:40:16 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:40:23 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025536927 Vs 16:40:29 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025532715 Vs 16:40:30 Magnet Current for MAIN, Imag = 200.1508 A Vtrans = 2.001453 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:40:37 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025534316 Vs 16:40:44 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025533803 Vs 16:40:45 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:40:52 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025548211 Vs 16:40:58 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025565784 Vs 16:40:59 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:41:06 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025555285 Vs 16:41:13 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025550553 Vs 16:41:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025546839 +- 0.000010209 Vs 16:41:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025546839 +- 0.000010209 Vs BL = 0.85156130 +- 0.00034031 Tm Remeasure 16:41:13 Integrated Voltage Measurement... 16:41:14 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:41:21 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025540406 Vs 16:41:28 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025523322 Vs 16:41:29 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:41:35 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025540155 Vs 16:41:42 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025554828 Vs 16:41:43 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:41:50 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025544363 Vs 16:41:57 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025554456 Vs 16:41:57 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:42:04 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025565123 Vs 16:42:11 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025546036 Vs 16:42:12 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:42:19 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025541065 Vs 16:42:26 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025551676 Vs 16:42:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025546143 +- 0.000007816 Vs 16:42:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025546143 +- 0.000007816 Vs BL = 0.85153810 +- 0.00026054 Tm Remeasure 16:42:26 Integrated Voltage Measurement... 16:42:27 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:42:34 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025539270 Vs 16:42:40 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025552136 Vs 16:42:41 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:42:48 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025557544 Vs 16:42:55 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025561784 Vs 16:42:56 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:43:03 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025551659 Vs 16:43:09 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025556949 Vs 16:43:10 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:43:17 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025566143 Vs 16:43:24 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025577132 Vs 16:43:25 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:43:32 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025538832 Vs 16:43:39 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025539313 Vs 16:43:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025554076 +- 0.000011269 Vs 16:43:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025554076 +- 0.000011269 Vs BL = 0.85180254 +- 0.00037562 Tm Remeasure 16:43:39 Integrated Voltage Measurement... 16:43:40 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:43:46 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025567933 Vs 16:43:53 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025563269 Vs 16:43:54 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:44:01 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025533532 Vs 16:44:08 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025546622 Vs 16:44:09 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:44:16 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025567230 Vs 16:44:23 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025547616 Vs 16:44:23 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:44:30 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025559357 Vs 16:44:37 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025527551 Vs 16:44:38 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:44:45 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025562744 Vs 16:44:52 Integrated Voltage Measurement X0 = 0.0180000 m, Delta X = -0.0030000 m VT = -0.025529689 Vs 16:44:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0180000 m, Delta X = 0.0030000 m VT = 0.025550554 +- 0.000009514 Vs 16:44:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0180000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025550554 +- 0.000009514 Vs BL = 0.85168514 +- 0.00031713 Tm 16:44:52 Integrated Voltage Measurement... 16:44:53 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:45:01 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025562549 Vs 16:45:08 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025534123 Vs 16:45:08 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:45:15 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025544183 Vs 16:45:22 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025528165 Vs 16:45:23 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:45:30 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025537800 Vs 16:45:37 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025547729 Vs 16:45:37 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:45:44 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025536781 Vs 16:45:51 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025531022 Vs 16:45:52 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:45:59 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025536391 Vs 16:46:06 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025538580 Vs 16:46:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025539732 +- 0.000005195 Vs 16:46:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0210000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025539732 +- 0.000005195 Vs BL = 0.85132441 +- 0.00017316 Tm Remeasure 16:46:06 Integrated Voltage Measurement... 16:46:07 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:46:14 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025535271 Vs 16:46:20 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025546437 Vs 16:46:21 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:46:28 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025531883 Vs 16:46:35 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025531868 Vs 16:46:36 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:46:43 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025535587 Vs 16:46:50 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025541714 Vs 16:46:51 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:46:57 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025537507 Vs 16:47:04 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025542553 Vs 16:47:05 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:47:12 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025537423 Vs 16:47:19 Integrated Voltage Measurement X0 = 0.0210000 m, Delta X = -0.0030000 m VT = -0.025531227 Vs 16:47:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0210000 m, Delta X = 0.0030000 m VT = 0.025537147 +- 0.000003466 Vs 16:47:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0210000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025537147 +- 0.000003466 Vs BL = 0.85123823 +- 0.00011554 Tm 16:47:19 Integrated Voltage Measurement... 16:47:20 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:47:28 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025557546 Vs 16:47:35 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025552141 Vs 16:47:35 Magnet Current for MAIN, Imag = 200.1506 A Vtrans = 2.001452 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:47:42 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025549447 Vs 16:47:49 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025537491 Vs 16:47:50 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:47:57 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025539679 Vs 16:48:04 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025524175 Vs 16:48:04 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:48:11 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025540026 Vs 16:48:18 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025513350 Vs 16:48:19 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:48:26 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025542682 Vs 16:48:33 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025565299 Vs 16:48:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025542184 +- 0.000011372 Vs 16:48:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025542184 +- 0.000011372 Vs BL = 0.85140612 +- 0.00037907 Tm Remeasure 16:48:33 Integrated Voltage Measurement... 16:48:34 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:48:41 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025534981 Vs 16:48:48 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025551295 Vs 16:48:48 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:48:55 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025564665 Vs 16:49:02 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025522915 Vs 16:49:03 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:49:10 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025545211 Vs 16:49:17 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025557174 Vs 16:49:18 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:49:24 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025547666 Vs 16:49:31 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025509621 Vs 16:49:32 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:49:39 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025563216 Vs 16:49:46 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025526803 Vs 16:49:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025542355 +- 0.000007427 Vs 16:49:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025542355 +- 0.000007427 Vs BL = 0.85141182 +- 0.00024758 Tm Remeasure 16:49:46 Integrated Voltage Measurement... 16:49:47 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:49:53 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025550745 Vs 16:50:00 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025560850 Vs 16:50:01 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:50:08 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025540718 Vs 16:50:15 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025516507 Vs 16:50:16 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:50:23 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025533921 Vs 16:50:30 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025536142 Vs 16:50:30 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:50:37 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025554662 Vs 16:50:44 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025534446 Vs 16:50:45 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:50:52 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025536905 Vs 16:50:59 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025551623 Vs 16:50:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025541652 +- 0.000009265 Vs 16:50:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025541652 +- 0.000009265 Vs BL = 0.85138840 +- 0.00030884 Tm Remeasure 16:50:59 Integrated Voltage Measurement... 16:51:00 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:51:06 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025544378 Vs 16:51:13 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025525101 Vs 16:51:14 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:51:21 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025534820 Vs 16:51:28 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025566656 Vs 16:51:29 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:51:36 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025536730 Vs 16:51:43 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025573645 Vs 16:51:43 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:51:50 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025554030 Vs 16:51:57 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025553457 Vs 16:51:58 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:52:05 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025550573 Vs 16:52:12 Integrated Voltage Measurement X0 = 0.0240000 m, Delta X = -0.0030000 m VT = -0.025550278 Vs 16:52:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0240000 m, Delta X = 0.0030000 m VT = 0.025548967 +- 0.000007338 Vs 16:52:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0240000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025548967 +- 0.000007338 Vs BL = 0.85163223 +- 0.00024459 Tm 16:52:12 Integrated Voltage Measurement... 16:52:13 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:52:21 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025530645 Vs 16:52:28 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = -0.025551236 Vs 16:52:28 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:52:35 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025544495 Vs 16:52:42 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = -0.025542940 Vs 16:52:43 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:52:50 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025553561 Vs 16:52:57 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = -0.025531563 Vs 16:52:58 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:53:05 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025551493 Vs 16:53:11 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = -0.025541575 Vs 16:53:12 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:53:19 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025537460 Vs 16:53:26 Integrated Voltage Measurement X0 = 0.0270000 m, Delta X = -0.0030000 m VT = -0.025533129 Vs 16:53:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0270000 m, Delta X = 0.0030000 m VT = 0.025541810 +- 0.000003735 Vs 16:53:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0270000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025541810 +- 0.000003735 Vs BL = 0.85139366 +- 0.00012449 Tm 16:53:26 Integrated Voltage Measurement... 16:53:27 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:53:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025559901 Vs 16:53:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025543515 Vs 16:53:42 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:53:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025544576 Vs 16:53:56 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025518164 Vs 16:53:57 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:54:04 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025540137 Vs 16:54:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025509124 Vs 16:54:11 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:54:18 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025536040 Vs 16:54:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025528224 Vs 16:54:26 Magnet Current for MAIN, Imag = 200.1519 A Vtrans = 2.001465 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:54:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025535743 Vs 16:54:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025523619 Vs 16:54:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025533904 +- 0.000009278 Vs 16:54:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025533904 +- 0.000009278 Vs BL = 0.85113014 +- 0.00030926 Tm Remeasure 16:54:40 Integrated Voltage Measurement... 16:54:40 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:54:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025555629 Vs 16:54:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025546572 Vs 16:54:55 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:55:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025538664 Vs 16:55:09 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025543952 Vs 16:55:09 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:55:16 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025541858 Vs 16:55:23 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025506222 Vs 16:55:24 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:55:31 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025542999 Vs 16:55:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025536701 Vs 16:55:39 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:55:46 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025546348 Vs 16:55:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025554813 Vs 16:55:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025541376 +- 0.000009820 Vs 16:55:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025541376 +- 0.000009820 Vs BL = 0.85137920 +- 0.00032734 Tm Remeasure 16:55:53 Integrated Voltage Measurement... 16:55:53 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:56:00 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025546583 Vs 16:56:07 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025509003 Vs 16:56:08 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:56:15 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025558072 Vs 16:56:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025500321 Vs 16:56:22 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:56:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025556412 Vs 16:56:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025526023 Vs 16:56:37 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:56:44 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025547440 Vs 16:56:51 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025531145 Vs 16:56:51 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:56:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025529130 Vs 16:57:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0030000 m VT = -0.025528504 Vs 16:57:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0030000 m VT = 0.025533264 +- 0.000005759 Vs 16:57:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025533264 +- 0.000005759 Vs BL = 0.85110878 +- 0.00019198 Tm 16:57:05 Integrated Voltage Measurement... 16:57:06 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:57:14 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025515481 Vs 16:57:21 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = -0.025560099 Vs 16:57:22 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:57:29 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025553882 Vs 16:57:35 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = -0.025531626 Vs 16:57:36 Magnet Current for MAIN, Imag = 200.1519 A Vtrans = 2.001465 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:57:43 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025548044 Vs 16:57:50 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = -0.025512685 Vs 16:57:51 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:57:58 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025546081 Vs 16:58:05 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = -0.025537229 Vs 16:58:06 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:58:12 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025546682 Vs 16:58:19 Integrated Voltage Measurement X0 = 0.0330000 m, Delta X = -0.0030000 m VT = -0.025541150 Vs 16:58:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0330000 m, Delta X = 0.0030000 m VT = 0.025539296 +- 0.000004918 Vs 16:58:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0330000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025539296 +- 0.000004918 Vs BL = 0.85130987 +- 0.00016392 Tm 16:58:19 Integrated Voltage Measurement... 16:58:20 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:58:28 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025551305 Vs 16:58:35 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025539598 Vs 16:58:36 Magnet Current for MAIN, Imag = 200.1510 A Vtrans = 2.001456 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:58:43 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025554205 Vs 16:58:50 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025555319 Vs 16:58:51 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:58:58 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025537002 Vs 16:59:04 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025542573 Vs 16:59:05 Magnet Current for MAIN, Imag = 200.1509 A Vtrans = 2.001454 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:59:12 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025537076 Vs 16:59:19 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025539000 Vs 16:59:20 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:59:26 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025544147 Vs 16:59:33 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025537801 Vs 16:59:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025543803 +- 0.000006003 Vs 16:59:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0360000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025543803 +- 0.000006003 Vs BL = 0.85146009 +- 0.00020010 Tm Remeasure 16:59:34 Integrated Voltage Measurement... 16:59:34 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:59:41 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025542985 Vs 16:59:48 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025515887 Vs 16:59:49 Magnet Current for MAIN, Imag = 200.1518 A Vtrans = 2.001463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 16:59:56 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025548507 Vs 17:00:03 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025534265 Vs 17:00:03 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:00:10 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025544362 Vs 17:00:17 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025561640 Vs 17:00:18 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:00:25 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025539873 Vs 17:00:32 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025544881 Vs 17:00:32 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:00:39 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025544622 Vs 17:00:46 Integrated Voltage Measurement X0 = 0.0360000 m, Delta X = -0.0030000 m VT = -0.025529516 Vs 17:00:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0360000 m, Delta X = 0.0030000 m VT = 0.025540654 +- 0.000007677 Vs 17:00:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0360000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025540654 +- 0.000007677 Vs BL = 0.85135513 +- 0.00025588 Tm 17:00:46 Integrated Voltage Measurement... 17:00:47 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:00:55 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025526186 Vs 17:01:02 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = -0.025542002 Vs 17:01:03 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:01:10 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025535918 Vs 17:01:17 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = -0.025548120 Vs 17:01:17 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:01:24 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025537526 Vs 17:01:31 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = -0.025534814 Vs 17:01:32 Magnet Current for MAIN, Imag = 200.1512 A Vtrans = 2.001457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:01:39 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025550611 Vs 17:01:46 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = -0.025534080 Vs 17:01:46 Magnet Current for MAIN, Imag = 200.1518 A Vtrans = 2.001463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:01:53 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025538914 Vs 17:02:00 Integrated Voltage Measurement X0 = 0.0390000 m, Delta X = -0.0030000 m VT = -0.025542839 Vs 17:02:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0390000 m, Delta X = 0.0030000 m VT = 0.025539101 +- 0.000003342 Vs 17:02:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0390000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025539101 +- 0.000003342 Vs BL = 0.85130337 +- 0.00011141 Tm 17:02:00 Integrated Voltage Measurement... 17:02:01 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:02:09 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025553249 Vs 17:02:16 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = -0.025557864 Vs 17:02:17 Magnet Current for MAIN, Imag = 200.1514 A Vtrans = 2.001460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:02:24 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025550479 Vs 17:02:31 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = -0.025565221 Vs 17:02:32 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:02:39 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025558274 Vs 17:02:45 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = -0.025538318 Vs 17:02:46 Magnet Current for MAIN, Imag = 200.1518 A Vtrans = 2.001463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:02:53 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025554992 Vs 17:03:00 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = -0.025538219 Vs 17:03:01 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:03:08 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025552603 Vs 17:03:15 Integrated Voltage Measurement X0 = 0.0420000 m, Delta X = -0.0030000 m VT = -0.025550606 Vs 17:03:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0420000 m, Delta X = 0.0030000 m VT = 0.025551983 +- 0.000004239 Vs 17:03:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0420000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025551983 +- 0.000004239 Vs BL = 0.85173275 +- 0.00014130 Tm 17:03:15 Integrated Voltage Measurement... 17:03:15 Magnet Current for MAIN, Imag = 200.1519 A Vtrans = 2.001465 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:03:24 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025571873 Vs 17:03:30 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = -0.025571277 Vs 17:03:31 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:03:38 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025569523 Vs 17:03:45 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = -0.025575467 Vs 17:03:46 Magnet Current for MAIN, Imag = 200.1517 A Vtrans = 2.001462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:03:53 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025575909 Vs 17:04:00 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = -0.025574046 Vs 17:04:00 Magnet Current for MAIN, Imag = 200.1513 A Vtrans = 2.001458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:04:07 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025571959 Vs 17:04:14 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = -0.025578481 Vs 17:04:15 Magnet Current for MAIN, Imag = 200.1515 A Vtrans = 2.001461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.005452 A 17:04:22 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025576911 Vs 17:04:29 Integrated Voltage Measurement X0 = 0.0450000 m, Delta X = -0.0030000 m VT = -0.025574543 Vs 17:04:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0450000 m, Delta X = 0.0030000 m VT = 0.025573999 +- 0.000001648 Vs 17:04:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0450000 m, dx = 0.0030000 m, Nturns = 10.0 VT = 0.025573999 +- 0.000001648 Vs BL = 0.85246663 +- 0.00005492 Tm 17:04:34 Position moved: 0.000000 m 17:04:37 Position moved: 0.000000 m 17:04:40 Magnet system MAIN current ramping to 0.0000 A...