SLAC Magnetic Measurements Date: 11-10-2025 Time: 11:50:30 Project: FACET-II Magnet Type: Dipole Magnet Name: 4595 Serial Number: 30822-4 Run Number: 6 Measurement Device: 1wire Operator: sda Comment: Degauss Currents f = 0.87 totals point = 50 Imax = 14.5. 3 times Test Currents for MAIN (A): 14.50 -12.62 10.98 -9.55 8.31 -7.23 6.29 -5.47 4.76 -4.14 3.60 -3.13 2.73 -2.37 2.06 -1.80 1.56 -1.36 1.18 -1.03 0.89 -0.78 0.68 -0.59 0.51 -0.45 0.39 -0.34 0.29 -0.26 0.22 -0.19 0.17 -0.15 0.13 -0.11 0.10 -0.08 0.07 -0.06 0.06 -0.05 0.04 -0.04 0.03 -0.03 0.02 -0.02 0.00 11:51:08 Position moved: 0.000000 m 11:51:12 Magnet Current for MAIN, Imag = 0.0009 A Vtrans = 0.000075 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:51:13 Magnet Current for MAIN, Imag = 0.0018 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:51:14 Magnet Current for MAIN, Imag = 0.0018 A Vtrans = 0.000149 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:51:15 Magnet Current for MAIN, Imag = 0.0021 A Vtrans = 0.000174 V, Factor V/A = 0.083333 V/A, Zero Current = 0.000000 A 11:51:15 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0016 +- 0.0004 A 11:51:30 Initial Zero Current Measurement for MAIN, Imag_zero = 0.001641 A 11:51:30 Ambient Measurement Device(s) Being Used, type = None 11:51:31 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 11:51:31 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 11:51:31 Ambient Measurement Device(s) Being Used, type = None 11:51:34 Position moved: 0.000000 m 11:51:37 Magnet system MAIN current ramping to 14.5000 A... 11:51:47 Magnet system MAIN current ramping to -12.6150 A... 11:52:04 Magnet system MAIN current ramping to 10.9750 A... 11:52:20 Magnet system MAIN current ramping to -9.5483 A... 11:52:33 Magnet system MAIN current ramping to 8.3070 A... 11:52:46 Magnet system MAIN current ramping to -7.2271 A... 11:52:57 Magnet system MAIN current ramping to 6.2876 A... 11:53:07 Magnet system MAIN current ramping to -5.4702 A... 11:53:16 Magnet system MAIN current ramping to 4.7591 A... 11:53:25 Magnet system MAIN current ramping to -4.1404 A... 11:53:33 Magnet system MAIN current ramping to 3.6021 A... 11:53:40 Magnet system MAIN current ramping to -3.1339 A... 11:53:47 Magnet system MAIN current ramping to 2.7265 A... 11:53:53 Magnet system MAIN current ramping to -2.3720 A... 11:53:59 Magnet system MAIN current ramping to 2.0637 A... 11:54:05 Magnet system MAIN current ramping to -1.7954 A... 11:54:10 Magnet system MAIN current ramping to 1.5620 A... 11:54:15 Magnet system MAIN current ramping to -1.3589 A... 11:54:20 Magnet system MAIN current ramping to 1.1823 A... 11:54:25 Magnet system MAIN current ramping to -1.0286 A... 11:54:30 Magnet system MAIN current ramping to 0.8949 A... 11:54:34 Magnet system MAIN current ramping to -0.7785 A... 11:54:38 Magnet system MAIN current ramping to 0.6773 A... 11:54:42 Magnet system MAIN current ramping to -0.5893 A... 11:54:46 Magnet system MAIN current ramping to 0.5127 A... 11:54:50 Magnet system MAIN current ramping to -0.4460 A... 11:54:54 Magnet system MAIN current ramping to 0.3880 A... 11:54:58 Magnet system MAIN current ramping to -0.3376 A... 11:55:02 Magnet system MAIN current ramping to 0.2937 A... 11:55:06 Magnet system MAIN current ramping to -0.2555 A... 11:55:09 Magnet system MAIN current ramping to 0.2223 A... 11:55:13 Magnet system MAIN current ramping to -0.1934 A... 11:55:17 Magnet system MAIN current ramping to 0.1683 A... 11:55:20 Magnet system MAIN current ramping to -0.1464 A... 11:55:24 Magnet system MAIN current ramping to 0.1274 A... 11:55:28 Magnet system MAIN current ramping to -0.1108 A... 11:55:31 Magnet system MAIN current ramping to 0.0964 A... 11:55:35 Magnet system MAIN current ramping to -0.0839 A... 11:55:38 Magnet system MAIN current ramping to 0.0730 A... 11:55:42 Magnet system MAIN current ramping to -0.0635 A... 11:55:45 Magnet system MAIN current ramping to 0.0552 A... 11:55:49 Magnet system MAIN current ramping to -0.0481 A... 11:55:52 Magnet system MAIN current ramping to 0.0418 A... 11:55:56 Magnet system MAIN current ramping to -0.0364 A... 11:55:59 Magnet system MAIN current ramping to 0.0316 A... 11:56:03 Magnet system MAIN current ramping to -0.0275 A... 11:56:06 Magnet system MAIN current ramping to 0.0239 A... 11:56:10 Magnet system MAIN current ramping to -0.0208 A... 11:56:13 Magnet system MAIN current ramping to 0.0000 A... 12:04:47 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:04:47 Main (V) Voltage Measurement, V = 0.000000 V 12:04:54 Temperature Measurement, Probe Number = 0, T = 22.866000 C 12:04:55 Temperature Measurement, Probe Number = 1, T = 22.677000 C 12:04:56 Temperature Measurement, Probe Number = 2, T = 22.427000 C 12:04:57 Temperature Measurement, Probe Number = 3, T = 23.069000 C 12:04:57 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 22.87 P3 = Coil_Top_Outside, Value = 22.68 P4 = Core, Value = 22.43 P5 = Ambient, Value = 23.07 12:04:57 Magnetic Field Measurement Measuring the magnet strength... 12:04:57 Integrated Voltage Measurement... 12:04:58 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:05:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004198 Vs 12:05:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004982 Vs 12:05:17 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:05:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004292 Vs 12:05:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004815 Vs 12:05:35 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:05:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004650 Vs 12:05:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004845 Vs 12:05:54 Magnet Current for MAIN, Imag = -0.0012 A Vtrans = 0.000037 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:06:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005212 Vs 12:06:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004650 Vs 12:06:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000118 +- 0.000000252 Vs 12:06:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000118 +- 0.000000252 Vs BL = 0.00001175 +- 0.00002525 Tm 12:06:15 Position moved: 0.000000 m 12:06:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00001 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00001 0.00003 0.00001 0.00000 12:06:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00001 0.00003 SL = 0.0000118 +- 0.0000252 Tm^2/m^n 12:06:15 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000118 +- 0.0000252 Tm^2/m^n 12:06:17 Position moved: 0.000000 m 12:10:24 Magnet system MAIN current ramping to 14.5000 A... 12:10:35 Magnet system MAIN current ramping to -12.6150 A... 12:10:52 Magnet system MAIN current ramping to 10.9750 A... 12:11:07 Magnet system MAIN current ramping to -9.5483 A... 12:11:20 Magnet system MAIN current ramping to 8.3070 A... 12:11:33 Magnet system MAIN current ramping to -7.2271 A... 12:11:44 Magnet system MAIN current ramping to 6.2876 A... 12:11:54 Magnet system MAIN current ramping to -5.4702 A... 12:12:03 Magnet system MAIN current ramping to 4.7591 A... 12:12:12 Magnet system MAIN current ramping to -4.1404 A... 12:12:20 Magnet system MAIN current ramping to 3.6021 A... 12:12:27 Magnet system MAIN current ramping to -3.1339 A... 12:12:34 Magnet system MAIN current ramping to 2.7265 A... 12:12:40 Magnet system MAIN current ramping to -2.3720 A... 12:12:46 Magnet system MAIN current ramping to 2.0637 A... 12:12:52 Magnet system MAIN current ramping to -1.7954 A... 12:12:57 Magnet system MAIN current ramping to 1.5620 A... 12:13:02 Magnet system MAIN current ramping to -1.3589 A... 12:13:07 Magnet system MAIN current ramping to 1.1823 A... 12:13:12 Magnet system MAIN current ramping to -1.0286 A... 12:13:17 Magnet system MAIN current ramping to 0.8949 A... 12:13:21 Magnet system MAIN current ramping to -0.7785 A... 12:13:25 Magnet system MAIN current ramping to 0.6773 A... 12:13:29 Magnet system MAIN current ramping to -0.5893 A... 12:13:34 Magnet system MAIN current ramping to 0.5127 A... 12:13:37 Magnet system MAIN current ramping to -0.4460 A... 12:13:41 Magnet system MAIN current ramping to 0.3880 A... 12:13:45 Magnet system MAIN current ramping to -0.3376 A... 12:13:49 Magnet system MAIN current ramping to 0.2937 A... 12:13:53 Magnet system MAIN current ramping to -0.2555 A... 12:13:56 Magnet system MAIN current ramping to 0.2223 A... 12:14:00 Magnet system MAIN current ramping to -0.1934 A... 12:14:04 Magnet system MAIN current ramping to 0.1683 A... 12:14:07 Magnet system MAIN current ramping to -0.1464 A... 12:14:11 Magnet system MAIN current ramping to 0.1274 A... 12:14:15 Magnet system MAIN current ramping to -0.1108 A... 12:14:18 Magnet system MAIN current ramping to 0.0964 A... 12:14:22 Magnet system MAIN current ramping to -0.0839 A... 12:14:25 Magnet system MAIN current ramping to 0.0730 A... 12:14:29 Magnet system MAIN current ramping to -0.0635 A... 12:14:32 Magnet system MAIN current ramping to 0.0552 A... 12:14:36 Magnet system MAIN current ramping to -0.0481 A... 12:14:39 Magnet system MAIN current ramping to 0.0418 A... 12:14:43 Magnet system MAIN current ramping to -0.0364 A... 12:14:46 Magnet system MAIN current ramping to 0.0316 A... 12:14:50 Magnet system MAIN current ramping to -0.0275 A... 12:14:53 Magnet system MAIN current ramping to 0.0239 A... 12:14:57 Magnet system MAIN current ramping to -0.0208 A... 12:15:00 Magnet system MAIN current ramping to 0.0000 A... 12:24:21 Magnet Current for MAIN, Imag = -0.0004 A Vtrans = 0.000100 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:24:21 Main (V) Voltage Measurement, V = 0.000075 V 12:24:25 Temperature Measurement, Probe Number = 0, T = 23.096000 C 12:24:26 Temperature Measurement, Probe Number = 1, T = 22.966000 C 12:24:27 Temperature Measurement, Probe Number = 2, T = 22.722000 C 12:24:28 Temperature Measurement, Probe Number = 3, T = 23.404000 C 12:24:28 Magnet Test Parameter Measurements P0 = MAIN, Value = -0.00 P1 = Main (V), Value = 0.00 P2 = Coil_Top_Inside, Value = 23.10 P3 = Coil_Top_Outside, Value = 22.97 P4 = Core, Value = 22.72 P5 = Ambient, Value = 23.40 12:24:28 Magnetic Field Measurement Measuring the magnet strength... 12:24:28 Integrated Voltage Measurement... 12:24:29 Magnet Current for MAIN, Imag = -0.0006 A Vtrans = 0.000087 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:24:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004687 Vs 12:24:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005300 Vs 12:24:48 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:24:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000005118 Vs 12:25:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005084 Vs 12:25:06 Magnet Current for MAIN, Imag = 0.0006 A Vtrans = 0.000187 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:25:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004823 Vs 12:25:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005021 Vs 12:25:24 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:25:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004745 Vs 12:25:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005351 Vs 12:25:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000173 +- 0.000000138 Vs 12:25:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000173 +- 0.000000138 Vs BL = 0.00001726 +- 0.00001381 Tm 12:25:45 Position moved: 0.000000 m 12:25:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00002 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00002 0.00001 0.00002 0.00000 12:25:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00002 0.00001 SL = 0.0000173 +- 0.0000138 Tm^2/m^n 12:25:45 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000173 +- 0.0000138 Tm^2/m^n 12:25:48 Position moved: 0.000000 m 12:26:24 Magnet system MAIN current ramping to 14.5000 A... 12:26:34 Magnet system MAIN current ramping to -12.6150 A... 12:26:51 Magnet system MAIN current ramping to 10.9750 A... 12:27:06 Magnet system MAIN current ramping to -9.5483 A... 12:27:20 Magnet system MAIN current ramping to 8.3070 A... 12:27:32 Magnet system MAIN current ramping to -7.2271 A... 12:27:44 Magnet system MAIN current ramping to 6.2876 A... 12:27:54 Magnet system MAIN current ramping to -5.4702 A... 12:28:03 Magnet system MAIN current ramping to 4.7591 A... 12:28:12 Magnet system MAIN current ramping to -4.1404 A... 12:28:20 Magnet system MAIN current ramping to 3.6021 A... 12:28:27 Magnet system MAIN current ramping to -3.1339 A... 12:28:34 Magnet system MAIN current ramping to 2.7265 A... 12:28:40 Magnet system MAIN current ramping to -2.3720 A... 12:28:46 Magnet system MAIN current ramping to 2.0637 A... 12:28:52 Magnet system MAIN current ramping to -1.7954 A... 12:28:57 Magnet system MAIN current ramping to 1.5620 A... 12:29:02 Magnet system MAIN current ramping to -1.3589 A... 12:29:07 Magnet system MAIN current ramping to 1.1823 A... 12:29:12 Magnet system MAIN current ramping to -1.0286 A... 12:29:16 Magnet system MAIN current ramping to 0.8949 A... 12:29:21 Magnet system MAIN current ramping to -0.7785 A... 12:29:25 Magnet system MAIN current ramping to 0.6773 A... 12:29:29 Magnet system MAIN current ramping to -0.5893 A... 12:29:33 Magnet system MAIN current ramping to 0.5127 A... 12:29:37 Magnet system MAIN current ramping to -0.4460 A... 12:29:41 Magnet system MAIN current ramping to 0.3880 A... 12:29:45 Magnet system MAIN current ramping to -0.3376 A... 12:29:49 Magnet system MAIN current ramping to 0.2937 A... 12:29:53 Magnet system MAIN current ramping to -0.2555 A... 12:29:56 Magnet system MAIN current ramping to 0.2223 A... 12:30:00 Magnet system MAIN current ramping to -0.1934 A... 12:30:04 Magnet system MAIN current ramping to 0.1683 A... 12:30:07 Magnet system MAIN current ramping to -0.1464 A... 12:30:11 Magnet system MAIN current ramping to 0.1274 A... 12:30:14 Magnet system MAIN current ramping to -0.1108 A... 12:30:18 Magnet system MAIN current ramping to 0.0964 A... 12:30:22 Magnet system MAIN current ramping to -0.0839 A... 12:30:25 Magnet system MAIN current ramping to 0.0730 A... 12:30:28 Magnet system MAIN current ramping to -0.0635 A... 12:30:32 Magnet system MAIN current ramping to 0.0552 A... 12:30:35 Magnet system MAIN current ramping to -0.0481 A... 12:30:39 Magnet system MAIN current ramping to 0.0418 A... 12:30:42 Magnet system MAIN current ramping to -0.0364 A... 12:30:46 Magnet system MAIN current ramping to 0.0316 A... 12:30:49 Magnet system MAIN current ramping to -0.0275 A... 12:30:53 Magnet system MAIN current ramping to 0.0239 A... 12:30:56 Magnet system MAIN current ramping to -0.0208 A... 12:31:00 Magnet system MAIN current ramping to 0.0000 A... 12:32:41 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = 0.000162 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:32:42 Main (V) Voltage Measurement, V = -0.000050 V 12:32:46 Temperature Measurement, Probe Number = 0, T = 23.369000 C 12:32:47 Temperature Measurement, Probe Number = 1, T = 23.181000 C 12:32:48 Temperature Measurement, Probe Number = 2, T = 22.856000 C 12:32:48 Temperature Measurement, Probe Number = 3, T = 23.507000 C 12:32:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = Main (V), Value = -0.00 P2 = Coil_Top_Inside, Value = 23.37 P3 = Coil_Top_Outside, Value = 23.18 P4 = Core, Value = 22.86 P5 = Ambient, Value = 23.51 12:32:48 Magnetic Field Measurement Measuring the magnet strength... 12:32:48 Integrated Voltage Measurement... 12:32:49 Magnet Current for MAIN, Imag = 0.0000 A Vtrans = 0.000137 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:32:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004669 Vs 12:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004977 Vs 12:33:09 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004964 Vs 12:33:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000004765 Vs 12:33:27 Magnet Current for MAIN, Imag = -0.0002 A Vtrans = 0.000124 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:33:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004911 Vs 12:33:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005159 Vs 12:33:45 Magnet Current for MAIN, Imag = -0.0003 A Vtrans = 0.000112 V, Factor V/A = 0.083333 V/A, Zero Current = 0.001641 A 12:33:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000004737 Vs 12:34:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000005147 Vs 12:34:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000000096 +- 0.000000117 Vs 12:34:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 1.0 VT = 0.000000096 +- 0.000000117 Vs BL = 0.00000959 +- 0.00001166 Tm 12:34:06 Position moved: 0.000000 m 12:34:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00001 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.00001 0.00001 0.00001 0.00000 12:34:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.00001 0.00001 SL = 0.0000096 +- 0.0000117 Tm^2/m^n 12:34:06 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0000096 +- 0.0000117 Tm^2/m^n 12:34:09 Position moved: 0.000000 m 12:34:34 Position moved: 0.000000 m 12:34:37 Magnet system MAIN current ramping to 0.0000 A...