SLAC Magnetic Measurements Date: 07-13-2018 Time: 15:27:34 Project: FACET_II Magnet Type: Dipole Magnet Name: 1.69D6.28T-178701-7 Serial Number: 7 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated field strength with Main from 0 to 380 to 0 A in 14 A steps. Standardization for MAIN: 15 cycles from 0.0 A to 380.0 A to 0.0 A Test Currents for MAIN (A): 0.00 14.00 28.00 42.00 56.00 70.00 84.00 98.00 112.00 126.00 140.00 154.00 168.00 182.00 196.00 210.00 224.00 238.00 252.00 266.00 280.00 294.00 308.00 322.00 336.00 350.00 364.00 378.00 380.00 378.00 364.00 350.00 336.00 322.00 308.00 294.00 280.00 266.00 252.00 238.00 224.00 210.00 196.00 182.00 168.00 154.00 140.00 126.00 112.00 98.00 84.00 70.00 56.00 42.00 28.00 14.00 0.00 15:28:07 Position moved: 0.000000 m 15:28:50 Magnet Current for MAIN, Imag = -0.0068 A Vtrans = -0.000068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:51 Magnet Current for MAIN, Imag = -0.0068 A Vtrans = -0.000068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:52 Magnet Current for MAIN, Imag = -0.0068 A Vtrans = -0.000068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:52 Magnet Current for MAIN, Imag = -0.0068 A Vtrans = -0.000068 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 15:28:52 Magnet Avgerage Current Measurement for MAIN : Imag = -0.0068 +- 0.0000 A 15:29:19 Initial Zero Current Measurement for MAIN, Imag_zero = -0.00680363 A 15:29:20 Ambient Measurement Device(s) Being Used, type = None 15:29:20 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 15:29:20 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 15:29:20 XMAG Device(s) Being Used, type = None 15:29:21 Ambient Measurement Device(s) Being Used, type = HP34970 15:29:21 Magnet system MAIN current ramping to 308.0000 A... 15:30:48 Magnet Current for MAIN, Imag = 308.0874 A Vtrans = 3.080806 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:30:48 MAIN (V) Voltage Measurement, V = 11.852458 V 15:30:49 Temperature Measurement, Probe Number = 0, T = 29.520000 C 15:30:50 Temperature Measurement, Probe Number = 1, T = 29.722000 C 15:30:50 Temperature Measurement, Probe Number = 2, T = 28.458000 C 15:30:51 Temperature Measurement, Probe Number = 3, T = 29.368000 C 15:30:52 Temperature Measurement, Probe Number = 4, T = 27.190000 C 15:30:52 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006862 V 15:30:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006862 (V, A, ohm, ...), Measured Value = 0.514620 (C, atm, Hz, ...) 15:30:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001678 V 15:30:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001678 (V, A, ohm, ...), Measured Value = 0.125850 (C, atm, Hz, ...) 15:30:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.013876 V 15:30:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.013876 (V, A, ohm, ...), Measured Value = -0.002357 (C, atm, Hz, ...) 15:30:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.85 P2 = Yoke, Value = 29.52 P3 = Coil, Value = 29.72 P4 = H20_In, Value = 28.46 P5 = H2O_Out, Value = 29.37 P6 = Ambient, Value = 27.19 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.13 P9 = Flow Rate(gpm), Value = -0.00 15:31:55 Magnet Current for MAIN, Imag = 308.0866 A Vtrans = 3.080798 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:31:55 MAIN (V) Voltage Measurement, V = 11.853917 V 15:31:56 Temperature Measurement, Probe Number = 0, T = 29.516000 C 15:31:56 Temperature Measurement, Probe Number = 1, T = 30.277000 C 15:31:57 Temperature Measurement, Probe Number = 2, T = 28.458000 C 15:31:58 Temperature Measurement, Probe Number = 3, T = 30.346000 C 15:31:58 Temperature Measurement, Probe Number = 4, T = 27.176000 C 15:31:59 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006930 V 15:31:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006930 (V, A, ohm, ...), Measured Value = 0.519750 (C, atm, Hz, ...) 15:32:00 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001600 V 15:32:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001600 (V, A, ohm, ...), Measured Value = 0.120037 (C, atm, Hz, ...) 15:32:00 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003924 V 15:32:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003924 (V, A, ohm, ...), Measured Value = -0.000666 (C, atm, Hz, ...) 15:32:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.85 P2 = Yoke, Value = 29.52 P3 = Coil, Value = 30.28 P4 = H20_In, Value = 28.46 P5 = H2O_Out, Value = 30.35 P6 = Ambient, Value = 27.18 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.12 P9 = Flow Rate(gpm), Value = -0.00 15:33:01 Magnet Current for MAIN, Imag = 308.0889 A Vtrans = 3.080821 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:33:02 MAIN (V) Voltage Measurement, V = 11.854515 V 15:33:02 Temperature Measurement, Probe Number = 0, T = 29.536000 C 15:33:03 Temperature Measurement, Probe Number = 1, T = 30.629000 C 15:33:04 Temperature Measurement, Probe Number = 2, T = 28.464000 C 15:33:04 Temperature Measurement, Probe Number = 3, T = 30.981000 C 15:33:05 Temperature Measurement, Probe Number = 4, T = 27.208000 C 15:33:05 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006944 V 15:33:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006944 (V, A, ohm, ...), Measured Value = 0.520815 (C, atm, Hz, ...) 15:33:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001719 V 15:33:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001719 (V, A, ohm, ...), Measured Value = 0.128955 (C, atm, Hz, ...) 15:33:07 Sensor Voltage Measurement, Sensor Number = 2, V = -0.005954 V 15:33:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.005954 (V, A, ohm, ...), Measured Value = -0.001011 (C, atm, Hz, ...) 15:33:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.85 P2 = Yoke, Value = 29.54 P3 = Coil, Value = 30.63 P4 = H20_In, Value = 28.46 P5 = H2O_Out, Value = 30.98 P6 = Ambient, Value = 27.21 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.13 P9 = Flow Rate(gpm), Value = -0.00 15:34:08 Magnet Current for MAIN, Imag = 308.0903 A Vtrans = 3.080835 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:34:08 MAIN (V) Voltage Measurement, V = 11.855230 V 15:34:09 Temperature Measurement, Probe Number = 0, T = 29.576000 C 15:34:09 Temperature Measurement, Probe Number = 1, T = 30.881000 C 15:34:10 Temperature Measurement, Probe Number = 2, T = 28.477000 C 15:34:11 Temperature Measurement, Probe Number = 3, T = 31.432000 C 15:34:11 Temperature Measurement, Probe Number = 4, T = 27.234000 C 15:34:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006930 V 15:34:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006930 (V, A, ohm, ...), Measured Value = 0.519750 (C, atm, Hz, ...) 15:34:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001802 V 15:34:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001802 (V, A, ohm, ...), Measured Value = 0.135150 (C, atm, Hz, ...) 15:34:13 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001707 V 15:34:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001707 (V, A, ohm, ...), Measured Value = -0.000290 (C, atm, Hz, ...) 15:34:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.58 P3 = Coil, Value = 30.88 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 31.43 P6 = Ambient, Value = 27.23 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:35:14 Magnet Current for MAIN, Imag = 308.0874 A Vtrans = 3.080806 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:35:15 MAIN (V) Voltage Measurement, V = 11.855554 V 15:35:15 Temperature Measurement, Probe Number = 0, T = 29.605000 C 15:35:16 Temperature Measurement, Probe Number = 1, T = 31.060000 C 15:35:17 Temperature Measurement, Probe Number = 2, T = 28.482000 C 15:35:17 Temperature Measurement, Probe Number = 3, T = 31.735000 C 15:35:18 Temperature Measurement, Probe Number = 4, T = 27.309000 C 15:35:18 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007009 V 15:35:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007009 (V, A, ohm, ...), Measured Value = 0.525660 (C, atm, Hz, ...) 15:35:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001664 V 15:35:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001664 (V, A, ohm, ...), Measured Value = 0.124785 (C, atm, Hz, ...) 15:35:20 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002839 V 15:35:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002839 (V, A, ohm, ...), Measured Value = -0.000482 (C, atm, Hz, ...) 15:35:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.61 P3 = Coil, Value = 31.06 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 31.73 P6 = Ambient, Value = 27.31 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.12 P9 = Flow Rate(gpm), Value = -0.00 15:36:20 Magnet Current for MAIN, Imag = 308.0919 A Vtrans = 3.080851 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:36:21 MAIN (V) Voltage Measurement, V = 11.856065 V 15:36:22 Temperature Measurement, Probe Number = 0, T = 29.640000 C 15:36:22 Temperature Measurement, Probe Number = 1, T = 31.196000 C 15:36:23 Temperature Measurement, Probe Number = 2, T = 28.495000 C 15:36:23 Temperature Measurement, Probe Number = 3, T = 31.904000 C 15:36:24 Temperature Measurement, Probe Number = 4, T = 27.348000 C 15:36:25 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006953 V 15:36:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006953 (V, A, ohm, ...), Measured Value = 0.521497 (C, atm, Hz, ...) 15:36:25 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001771 V 15:36:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001771 (V, A, ohm, ...), Measured Value = 0.132825 (C, atm, Hz, ...) 15:36:26 Sensor Voltage Measurement, Sensor Number = 2, V = -0.005046 V 15:36:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.005046 (V, A, ohm, ...), Measured Value = -0.000857 (C, atm, Hz, ...) 15:36:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.64 P3 = Coil, Value = 31.20 P4 = H20_In, Value = 28.50 P5 = H2O_Out, Value = 31.90 P6 = Ambient, Value = 27.35 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.13 P9 = Flow Rate(gpm), Value = -0.00 15:37:27 Magnet Current for MAIN, Imag = 308.0915 A Vtrans = 3.080847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:37:28 MAIN (V) Voltage Measurement, V = 11.856300 V 15:37:28 Temperature Measurement, Probe Number = 0, T = 29.658000 C 15:37:29 Temperature Measurement, Probe Number = 1, T = 31.293000 C 15:37:30 Temperature Measurement, Probe Number = 2, T = 28.504000 C 15:37:30 Temperature Measurement, Probe Number = 3, T = 31.945000 C 15:37:31 Temperature Measurement, Probe Number = 4, T = 27.371000 C 15:37:31 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006916 V 15:37:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006916 (V, A, ohm, ...), Measured Value = 0.518685 (C, atm, Hz, ...) 15:37:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001771 V 15:37:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001771 (V, A, ohm, ...), Measured Value = 0.132825 (C, atm, Hz, ...) 15:37:33 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000936 V 15:37:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000936 (V, A, ohm, ...), Measured Value = -0.000159 (C, atm, Hz, ...) 15:37:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.66 P3 = Coil, Value = 31.29 P4 = H20_In, Value = 28.50 P5 = H2O_Out, Value = 31.95 P6 = Ambient, Value = 27.37 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.13 P9 = Flow Rate(gpm), Value = -0.00 15:38:34 Magnet Current for MAIN, Imag = 308.0912 A Vtrans = 3.080844 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:38:34 MAIN (V) Voltage Measurement, V = 11.856192 V 15:38:35 Temperature Measurement, Probe Number = 0, T = 29.682000 C 15:38:35 Temperature Measurement, Probe Number = 1, T = 31.348000 C 15:38:36 Temperature Measurement, Probe Number = 2, T = 28.484000 C 15:38:37 Temperature Measurement, Probe Number = 3, T = 32.007000 C 15:38:37 Temperature Measurement, Probe Number = 4, T = 27.317000 C 15:38:38 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006807 V 15:38:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006807 (V, A, ohm, ...), Measured Value = 0.510547 (C, atm, Hz, ...) 15:38:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001812 V 15:38:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001812 (V, A, ohm, ...), Measured Value = 0.135930 (C, atm, Hz, ...) 15:38:39 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002447 V 15:38:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002447 (V, A, ohm, ...), Measured Value = -0.000416 (C, atm, Hz, ...) 15:38:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.68 P3 = Coil, Value = 31.35 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 32.01 P6 = Ambient, Value = 27.32 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:39:40 Magnet Current for MAIN, Imag = 308.0894 A Vtrans = 3.080826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:39:40 MAIN (V) Voltage Measurement, V = 11.856385 V 15:39:41 Temperature Measurement, Probe Number = 0, T = 29.700000 C 15:39:42 Temperature Measurement, Probe Number = 1, T = 31.381000 C 15:39:42 Temperature Measurement, Probe Number = 2, T = 28.501000 C 15:39:43 Temperature Measurement, Probe Number = 3, T = 32.057000 C 15:39:44 Temperature Measurement, Probe Number = 4, T = 27.340000 C 15:39:44 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006790 V 15:39:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006790 (V, A, ohm, ...), Measured Value = 0.509287 (C, atm, Hz, ...) 15:39:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001846 V 15:39:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001846 (V, A, ohm, ...), Measured Value = 0.138442 (C, atm, Hz, ...) 15:39:45 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000481 V 15:39:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000481 (V, A, ohm, ...), Measured Value = -0.000082 (C, atm, Hz, ...) 15:39:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.70 P3 = Coil, Value = 31.38 P4 = H20_In, Value = 28.50 P5 = H2O_Out, Value = 32.06 P6 = Ambient, Value = 27.34 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:40:46 Magnet Current for MAIN, Imag = 308.0899 A Vtrans = 3.080831 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:40:47 MAIN (V) Voltage Measurement, V = 11.856443 V 15:40:48 Temperature Measurement, Probe Number = 0, T = 29.719000 C 15:40:48 Temperature Measurement, Probe Number = 1, T = 31.401000 C 15:40:49 Temperature Measurement, Probe Number = 2, T = 28.508000 C 15:40:50 Temperature Measurement, Probe Number = 3, T = 32.014000 C 15:40:50 Temperature Measurement, Probe Number = 4, T = 27.304000 C 15:40:51 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006824 V 15:40:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006824 (V, A, ohm, ...), Measured Value = 0.511807 (C, atm, Hz, ...) 15:40:51 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001939 V 15:40:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001939 (V, A, ohm, ...), Measured Value = 0.145418 (C, atm, Hz, ...) 15:40:52 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003757 V 15:40:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003757 (V, A, ohm, ...), Measured Value = -0.000638 (C, atm, Hz, ...) 15:40:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.72 P3 = Coil, Value = 31.40 P4 = H20_In, Value = 28.51 P5 = H2O_Out, Value = 32.01 P6 = Ambient, Value = 27.30 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:41:53 Magnet Current for MAIN, Imag = 308.0896 A Vtrans = 3.080828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:41:54 MAIN (V) Voltage Measurement, V = 11.856601 V 15:41:54 Temperature Measurement, Probe Number = 0, T = 29.736000 C 15:41:55 Temperature Measurement, Probe Number = 1, T = 31.377000 C 15:41:56 Temperature Measurement, Probe Number = 2, T = 28.508000 C 15:41:56 Temperature Measurement, Probe Number = 3, T = 32.032000 C 15:41:57 Temperature Measurement, Probe Number = 4, T = 27.350000 C 15:41:58 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006894 V 15:41:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006894 (V, A, ohm, ...), Measured Value = 0.517042 (C, atm, Hz, ...) 15:41:58 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001810 V 15:41:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001810 (V, A, ohm, ...), Measured Value = 0.135735 (C, atm, Hz, ...) 15:41:59 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000885 V 15:41:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000885 (V, A, ohm, ...), Measured Value = -0.000150 (C, atm, Hz, ...) 15:41:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.74 P3 = Coil, Value = 31.38 P4 = H20_In, Value = 28.51 P5 = H2O_Out, Value = 32.03 P6 = Ambient, Value = 27.35 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:43:00 Magnet Current for MAIN, Imag = 308.0899 A Vtrans = 3.080831 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:43:00 MAIN (V) Voltage Measurement, V = 11.856598 V 15:43:01 Temperature Measurement, Probe Number = 0, T = 29.759000 C 15:43:02 Temperature Measurement, Probe Number = 1, T = 31.392000 C 15:43:02 Temperature Measurement, Probe Number = 2, T = 28.515000 C 15:43:03 Temperature Measurement, Probe Number = 3, T = 32.028000 C 15:43:03 Temperature Measurement, Probe Number = 4, T = 27.338000 C 15:43:04 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007009 V 15:43:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007009 (V, A, ohm, ...), Measured Value = 0.525660 (C, atm, Hz, ...) 15:43:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002053 V 15:43:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002053 (V, A, ohm, ...), Measured Value = 0.153945 (C, atm, Hz, ...) 15:43:05 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001171 V 15:43:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001171 (V, A, ohm, ...), Measured Value = -0.000199 (C, atm, Hz, ...) 15:43:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.76 P3 = Coil, Value = 31.39 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.03 P6 = Ambient, Value = 27.34 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:44:06 Magnet Current for MAIN, Imag = 308.0883 A Vtrans = 3.080815 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:44:07 MAIN (V) Voltage Measurement, V = 11.856636 V 15:44:07 Temperature Measurement, Probe Number = 0, T = 29.775000 C 15:44:08 Temperature Measurement, Probe Number = 1, T = 31.397000 C 15:44:09 Temperature Measurement, Probe Number = 2, T = 28.527000 C 15:44:09 Temperature Measurement, Probe Number = 3, T = 32.048000 C 15:44:10 Temperature Measurement, Probe Number = 4, T = 27.331000 C 15:44:10 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007022 V 15:44:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007022 (V, A, ohm, ...), Measured Value = 0.526627 (C, atm, Hz, ...) 15:44:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001935 V 15:44:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001935 (V, A, ohm, ...), Measured Value = 0.145133 (C, atm, Hz, ...) 15:44:12 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001733 V 15:44:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001733 (V, A, ohm, ...), Measured Value = -0.000294 (C, atm, Hz, ...) 15:44:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.77 P3 = Coil, Value = 31.40 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.05 P6 = Ambient, Value = 27.33 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:45:13 Magnet Current for MAIN, Imag = 308.0894 A Vtrans = 3.080826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:45:13 MAIN (V) Voltage Measurement, V = 11.856758 V 15:45:15 Temperature Measurement, Probe Number = 0, T = 29.809000 C 15:45:16 Temperature Measurement, Probe Number = 1, T = 31.404000 C 15:45:17 Temperature Measurement, Probe Number = 2, T = 28.527000 C 15:45:17 Temperature Measurement, Probe Number = 3, T = 32.116000 C 15:45:18 Temperature Measurement, Probe Number = 4, T = 27.398000 C 15:45:19 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007020 V 15:45:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007020 (V, A, ohm, ...), Measured Value = 0.526530 (C, atm, Hz, ...) 15:45:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001942 V 15:45:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001942 (V, A, ohm, ...), Measured Value = 0.145613 (C, atm, Hz, ...) 15:45:20 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000172 V 15:45:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000172 (V, A, ohm, ...), Measured Value = -0.000029 (C, atm, Hz, ...) 15:45:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.81 P3 = Coil, Value = 31.40 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.12 P6 = Ambient, Value = 27.40 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:46:21 Magnet Current for MAIN, Imag = 308.0903 A Vtrans = 3.080835 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:46:23 MAIN (V) Voltage Measurement, V = 11.857138 V 15:46:24 Temperature Measurement, Probe Number = 0, T = 29.836000 C 15:46:25 Temperature Measurement, Probe Number = 1, T = 31.430000 C 15:46:26 Temperature Measurement, Probe Number = 2, T = 28.527000 C 15:46:27 Temperature Measurement, Probe Number = 3, T = 32.085000 C 15:46:28 Temperature Measurement, Probe Number = 4, T = 27.448000 C 15:46:28 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007113 V 15:46:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007113 (V, A, ohm, ...), Measured Value = 0.533512 (C, atm, Hz, ...) 15:46:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001820 V 15:46:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001820 (V, A, ohm, ...), Measured Value = 0.136507 (C, atm, Hz, ...) 15:46:30 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004781 V 15:46:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004781 (V, A, ohm, ...), Measured Value = -0.000812 (C, atm, Hz, ...) 15:46:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.84 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.09 P6 = Ambient, Value = 27.45 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:47:31 Magnet Current for MAIN, Imag = 308.0905 A Vtrans = 3.080837 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:47:32 MAIN (V) Voltage Measurement, V = 11.857013 V 15:47:33 Temperature Measurement, Probe Number = 0, T = 29.862000 C 15:47:34 Temperature Measurement, Probe Number = 1, T = 31.418000 C 15:47:34 Temperature Measurement, Probe Number = 2, T = 28.518000 C 15:47:35 Temperature Measurement, Probe Number = 3, T = 32.156000 C 15:47:36 Temperature Measurement, Probe Number = 4, T = 27.411000 C 15:47:37 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007067 V 15:47:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007067 (V, A, ohm, ...), Measured Value = 0.530018 (C, atm, Hz, ...) 15:47:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002027 V 15:47:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002027 (V, A, ohm, ...), Measured Value = 0.152010 (C, atm, Hz, ...) 15:47:38 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003362 V 15:47:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003362 (V, A, ohm, ...), Measured Value = -0.000571 (C, atm, Hz, ...) 15:47:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.86 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.16 P6 = Ambient, Value = 27.41 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:48:40 Magnet Current for MAIN, Imag = 308.0906 A Vtrans = 3.080838 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:48:41 MAIN (V) Voltage Measurement, V = 11.857234 V 15:48:41 Temperature Measurement, Probe Number = 0, T = 29.880000 C 15:48:42 Temperature Measurement, Probe Number = 1, T = 31.412000 C 15:48:43 Temperature Measurement, Probe Number = 2, T = 28.520000 C 15:48:43 Temperature Measurement, Probe Number = 3, T = 32.225000 C 15:48:44 Temperature Measurement, Probe Number = 4, T = 27.452000 C 15:48:45 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006975 V 15:48:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006975 (V, A, ohm, ...), Measured Value = 0.523140 (C, atm, Hz, ...) 15:48:46 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002009 V 15:48:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002009 (V, A, ohm, ...), Measured Value = 0.150652 (C, atm, Hz, ...) 15:48:46 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002396 V 15:48:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002396 (V, A, ohm, ...), Measured Value = -0.000407 (C, atm, Hz, ...) 15:48:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.88 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.23 P6 = Ambient, Value = 27.45 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:49:47 Magnet Current for MAIN, Imag = 308.0911 A Vtrans = 3.080843 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:49:48 MAIN (V) Voltage Measurement, V = 11.857281 V 15:49:49 Temperature Measurement, Probe Number = 0, T = 29.906000 C 15:49:49 Temperature Measurement, Probe Number = 1, T = 31.431000 C 15:49:50 Temperature Measurement, Probe Number = 2, T = 28.523000 C 15:49:52 Temperature Measurement, Probe Number = 3, T = 32.184000 C 15:49:52 Temperature Measurement, Probe Number = 4, T = 27.473000 C 15:49:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006980 V 15:49:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006980 (V, A, ohm, ...), Measured Value = 0.523530 (C, atm, Hz, ...) 15:49:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001930 V 15:49:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001930 (V, A, ohm, ...), Measured Value = 0.144742 (C, atm, Hz, ...) 15:49:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003798 V 15:49:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003798 (V, A, ohm, ...), Measured Value = -0.000645 (C, atm, Hz, ...) 15:49:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.91 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.18 P6 = Ambient, Value = 27.47 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 15:50:57 Magnet Current for MAIN, Imag = 308.0897 A Vtrans = 3.080829 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:50:58 MAIN (V) Voltage Measurement, V = 11.857232 V 15:50:58 Temperature Measurement, Probe Number = 0, T = 29.927000 C 15:50:59 Temperature Measurement, Probe Number = 1, T = 31.430000 C 15:51:00 Temperature Measurement, Probe Number = 2, T = 28.529000 C 15:51:01 Temperature Measurement, Probe Number = 3, T = 32.189000 C 15:51:02 Temperature Measurement, Probe Number = 4, T = 27.435000 C 15:51:03 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007090 V 15:51:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007090 (V, A, ohm, ...), Measured Value = 0.531765 (C, atm, Hz, ...) 15:51:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001979 V 15:51:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001979 (V, A, ohm, ...), Measured Value = 0.148425 (C, atm, Hz, ...) 15:51:05 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001898 V 15:51:06 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001898 (V, A, ohm, ...), Measured Value = -0.000322 (C, atm, Hz, ...) 15:51:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.93 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.19 P6 = Ambient, Value = 27.43 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:52:08 Magnet Current for MAIN, Imag = 308.0896 A Vtrans = 3.080828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:52:08 MAIN (V) Voltage Measurement, V = 11.857396 V 15:52:09 Temperature Measurement, Probe Number = 0, T = 29.942000 C 15:52:10 Temperature Measurement, Probe Number = 1, T = 31.417000 C 15:52:10 Temperature Measurement, Probe Number = 2, T = 28.533000 C 15:52:11 Temperature Measurement, Probe Number = 3, T = 32.177000 C 15:52:12 Temperature Measurement, Probe Number = 4, T = 27.500000 C 15:52:13 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007104 V 15:52:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007104 (V, A, ohm, ...), Measured Value = 0.532830 (C, atm, Hz, ...) 15:52:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001964 V 15:52:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001964 (V, A, ohm, ...), Measured Value = 0.147263 (C, atm, Hz, ...) 15:52:15 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003067 V 15:52:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003067 (V, A, ohm, ...), Measured Value = -0.000521 (C, atm, Hz, ...) 15:52:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.94 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.18 P6 = Ambient, Value = 27.50 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:53:17 Magnet Current for MAIN, Imag = 308.0902 A Vtrans = 3.080834 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:53:18 MAIN (V) Voltage Measurement, V = 11.857479 V 15:53:19 Temperature Measurement, Probe Number = 0, T = 29.973000 C 15:53:20 Temperature Measurement, Probe Number = 1, T = 31.416000 C 15:53:20 Temperature Measurement, Probe Number = 2, T = 28.535000 C 15:53:21 Temperature Measurement, Probe Number = 3, T = 32.168000 C 15:53:21 Temperature Measurement, Probe Number = 4, T = 27.530000 C 15:53:23 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007130 V 15:53:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007130 (V, A, ohm, ...), Measured Value = 0.534765 (C, atm, Hz, ...) 15:53:24 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002032 V 15:53:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002032 (V, A, ohm, ...), Measured Value = 0.152392 (C, atm, Hz, ...) 15:53:24 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004480 V 15:53:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004480 (V, A, ohm, ...), Measured Value = -0.000761 (C, atm, Hz, ...) 15:53:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.97 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.17 P6 = Ambient, Value = 27.53 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 15:54:26 Magnet Current for MAIN, Imag = 308.0892 A Vtrans = 3.080824 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:54:26 MAIN (V) Voltage Measurement, V = 11.857575 V 15:54:27 Temperature Measurement, Probe Number = 0, T = 29.991000 C 15:54:28 Temperature Measurement, Probe Number = 1, T = 31.419000 C 15:54:28 Temperature Measurement, Probe Number = 2, T = 28.519000 C 15:54:29 Temperature Measurement, Probe Number = 3, T = 32.214000 C 15:54:30 Temperature Measurement, Probe Number = 4, T = 27.522000 C 15:54:30 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007182 V 15:54:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007182 (V, A, ohm, ...), Measured Value = 0.538642 (C, atm, Hz, ...) 15:54:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002138 V 15:54:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002138 (V, A, ohm, ...), Measured Value = 0.160342 (C, atm, Hz, ...) 15:54:32 Sensor Voltage Measurement, Sensor Number = 2, V = -0.005180 V 15:54:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.005180 (V, A, ohm, ...), Measured Value = -0.000880 (C, atm, Hz, ...) 15:54:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 29.99 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.21 P6 = Ambient, Value = 27.52 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 15:55:33 Magnet Current for MAIN, Imag = 308.0920 A Vtrans = 3.080852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:55:33 MAIN (V) Voltage Measurement, V = 11.857638 V 15:55:34 Temperature Measurement, Probe Number = 0, T = 30.013000 C 15:55:35 Temperature Measurement, Probe Number = 1, T = 31.426000 C 15:55:35 Temperature Measurement, Probe Number = 2, T = 28.525000 C 15:55:36 Temperature Measurement, Probe Number = 3, T = 32.173000 C 15:55:36 Temperature Measurement, Probe Number = 4, T = 27.507000 C 15:55:37 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007231 V 15:55:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007231 (V, A, ohm, ...), Measured Value = 0.542325 (C, atm, Hz, ...) 15:55:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002254 V 15:55:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002254 (V, A, ohm, ...), Measured Value = 0.169058 (C, atm, Hz, ...) 15:55:38 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001348 V 15:55:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001348 (V, A, ohm, ...), Measured Value = -0.000229 (C, atm, Hz, ...) 15:55:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.01 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.17 P6 = Ambient, Value = 27.51 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 15:56:39 Magnet Current for MAIN, Imag = 308.0910 A Vtrans = 3.080842 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:56:40 MAIN (V) Voltage Measurement, V = 11.857745 V 15:56:41 Temperature Measurement, Probe Number = 0, T = 30.037000 C 15:56:41 Temperature Measurement, Probe Number = 1, T = 31.414000 C 15:56:42 Temperature Measurement, Probe Number = 2, T = 28.514000 C 15:56:42 Temperature Measurement, Probe Number = 3, T = 32.227000 C 15:56:43 Temperature Measurement, Probe Number = 4, T = 27.489000 C 15:56:44 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007135 V 15:56:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007135 (V, A, ohm, ...), Measured Value = 0.535155 (C, atm, Hz, ...) 15:56:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002180 V 15:56:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002180 (V, A, ohm, ...), Measured Value = 0.163537 (C, atm, Hz, ...) 15:56:45 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003788 V 15:56:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003788 (V, A, ohm, ...), Measured Value = -0.000643 (C, atm, Hz, ...) 15:56:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.04 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.51 P5 = H2O_Out, Value = 32.23 P6 = Ambient, Value = 27.49 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 15:57:46 Magnet Current for MAIN, Imag = 308.0901 A Vtrans = 3.080833 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:57:46 MAIN (V) Voltage Measurement, V = 11.857834 V 15:57:47 Temperature Measurement, Probe Number = 0, T = 30.054000 C 15:57:47 Temperature Measurement, Probe Number = 1, T = 31.412000 C 15:57:48 Temperature Measurement, Probe Number = 2, T = 28.518000 C 15:57:49 Temperature Measurement, Probe Number = 3, T = 32.236000 C 15:57:49 Temperature Measurement, Probe Number = 4, T = 27.457000 C 15:57:50 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007223 V 15:57:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007223 (V, A, ohm, ...), Measured Value = 0.541740 (C, atm, Hz, ...) 15:57:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002139 V 15:57:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002139 (V, A, ohm, ...), Measured Value = 0.160440 (C, atm, Hz, ...) 15:57:51 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001802 V 15:57:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001802 (V, A, ohm, ...), Measured Value = -0.000306 (C, atm, Hz, ...) 15:57:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.05 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.24 P6 = Ambient, Value = 27.46 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 15:58:52 Magnet Current for MAIN, Imag = 308.0915 A Vtrans = 3.080847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:58:53 MAIN (V) Voltage Measurement, V = 11.857961 V 15:58:53 Temperature Measurement, Probe Number = 0, T = 30.070000 C 15:58:54 Temperature Measurement, Probe Number = 1, T = 31.431000 C 15:58:54 Temperature Measurement, Probe Number = 2, T = 28.527000 C 15:58:55 Temperature Measurement, Probe Number = 3, T = 32.277000 C 15:58:56 Temperature Measurement, Probe Number = 4, T = 27.512000 C 15:58:56 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007216 V 15:58:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007216 (V, A, ohm, ...), Measured Value = 0.541163 (C, atm, Hz, ...) 15:58:57 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002147 V 15:58:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002147 (V, A, ohm, ...), Measured Value = 0.161018 (C, atm, Hz, ...) 15:58:58 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003395 V 15:58:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003395 (V, A, ohm, ...), Measured Value = -0.000577 (C, atm, Hz, ...) 15:58:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.07 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.51 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 15:59:58 Magnet Current for MAIN, Imag = 308.0915 A Vtrans = 3.080847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 15:59:59 MAIN (V) Voltage Measurement, V = 11.858186 V 16:00:00 Temperature Measurement, Probe Number = 0, T = 30.079000 C 16:00:00 Temperature Measurement, Probe Number = 1, T = 31.432000 C 16:00:01 Temperature Measurement, Probe Number = 2, T = 28.529000 C 16:00:01 Temperature Measurement, Probe Number = 3, T = 32.267000 C 16:00:02 Temperature Measurement, Probe Number = 4, T = 27.552000 C 16:00:03 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007121 V 16:00:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007121 (V, A, ohm, ...), Measured Value = 0.534090 (C, atm, Hz, ...) 16:00:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002214 V 16:00:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002214 (V, A, ohm, ...), Measured Value = 0.166057 (C, atm, Hz, ...) 16:00:04 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004474 V 16:00:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004474 (V, A, ohm, ...), Measured Value = -0.000760 (C, atm, Hz, ...) 16:00:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.08 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.55 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:01:05 Magnet Current for MAIN, Imag = 308.0909 A Vtrans = 3.080840 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:01:05 MAIN (V) Voltage Measurement, V = 11.858484 V 16:01:06 Temperature Measurement, Probe Number = 0, T = 30.100000 C 16:01:07 Temperature Measurement, Probe Number = 1, T = 31.447000 C 16:01:07 Temperature Measurement, Probe Number = 2, T = 28.541000 C 16:01:08 Temperature Measurement, Probe Number = 3, T = 32.343000 C 16:01:08 Temperature Measurement, Probe Number = 4, T = 27.587000 C 16:01:09 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007122 V 16:01:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007122 (V, A, ohm, ...), Measured Value = 0.534187 (C, atm, Hz, ...) 16:01:10 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002244 V 16:01:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002244 (V, A, ohm, ...), Measured Value = 0.168285 (C, atm, Hz, ...) 16:01:11 Sensor Voltage Measurement, Sensor Number = 2, V = -0.021080 V 16:01:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.021080 (V, A, ohm, ...), Measured Value = -0.003580 (C, atm, Hz, ...) 16:01:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.10 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.34 P6 = Ambient, Value = 27.59 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:02:11 Magnet Current for MAIN, Imag = 308.0920 A Vtrans = 3.080852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:02:12 MAIN (V) Voltage Measurement, V = 11.858738 V 16:02:13 Temperature Measurement, Probe Number = 0, T = 30.129000 C 16:02:13 Temperature Measurement, Probe Number = 1, T = 31.467000 C 16:02:14 Temperature Measurement, Probe Number = 2, T = 28.545000 C 16:02:14 Temperature Measurement, Probe Number = 3, T = 32.224000 C 16:02:15 Temperature Measurement, Probe Number = 4, T = 27.607000 C 16:02:16 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007150 V 16:02:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007150 (V, A, ohm, ...), Measured Value = 0.536220 (C, atm, Hz, ...) 16:02:16 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002126 V 16:02:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002126 (V, A, ohm, ...), Measured Value = 0.159465 (C, atm, Hz, ...) 16:02:17 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002016 V 16:02:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002016 (V, A, ohm, ...), Measured Value = -0.000342 (C, atm, Hz, ...) 16:02:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.13 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.22 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:03:18 Magnet Current for MAIN, Imag = 308.0923 A Vtrans = 3.080855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:03:18 MAIN (V) Voltage Measurement, V = 11.858902 V 16:03:19 Temperature Measurement, Probe Number = 0, T = 30.139000 C 16:03:20 Temperature Measurement, Probe Number = 1, T = 31.449000 C 16:03:20 Temperature Measurement, Probe Number = 2, T = 28.543000 C 16:03:21 Temperature Measurement, Probe Number = 3, T = 32.209000 C 16:03:21 Temperature Measurement, Probe Number = 4, T = 27.573000 C 16:03:22 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007166 V 16:03:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007166 (V, A, ohm, ...), Measured Value = 0.537480 (C, atm, Hz, ...) 16:03:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002094 V 16:03:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002094 (V, A, ohm, ...), Measured Value = 0.157050 (C, atm, Hz, ...) 16:03:23 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001247 V 16:03:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001247 (V, A, ohm, ...), Measured Value = -0.000212 (C, atm, Hz, ...) 16:03:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.14 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.21 P6 = Ambient, Value = 27.57 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:04:24 Magnet Current for MAIN, Imag = 308.0916 A Vtrans = 3.080848 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:04:25 MAIN (V) Voltage Measurement, V = 11.859023 V 16:04:25 Temperature Measurement, Probe Number = 0, T = 30.158000 C 16:04:26 Temperature Measurement, Probe Number = 1, T = 31.438000 C 16:04:26 Temperature Measurement, Probe Number = 2, T = 28.541000 C 16:04:27 Temperature Measurement, Probe Number = 3, T = 32.212000 C 16:04:28 Temperature Measurement, Probe Number = 4, T = 27.540000 C 16:04:28 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007281 V 16:04:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007281 (V, A, ohm, ...), Measured Value = 0.546105 (C, atm, Hz, ...) 16:04:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002173 V 16:04:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002173 (V, A, ohm, ...), Measured Value = 0.162953 (C, atm, Hz, ...) 16:04:30 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000872 V 16:04:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000872 (V, A, ohm, ...), Measured Value = -0.000148 (C, atm, Hz, ...) 16:04:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.16 P3 = Coil, Value = 31.44 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.21 P6 = Ambient, Value = 27.54 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:05:30 Magnet Current for MAIN, Imag = 308.0923 A Vtrans = 3.080855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:05:31 MAIN (V) Voltage Measurement, V = 11.859422 V 16:05:32 Temperature Measurement, Probe Number = 0, T = 30.171000 C 16:05:32 Temperature Measurement, Probe Number = 1, T = 31.425000 C 16:05:33 Temperature Measurement, Probe Number = 2, T = 28.527000 C 16:05:33 Temperature Measurement, Probe Number = 3, T = 32.278000 C 16:05:34 Temperature Measurement, Probe Number = 4, T = 27.510000 C 16:05:35 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007108 V 16:05:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007108 (V, A, ohm, ...), Measured Value = 0.533123 (C, atm, Hz, ...) 16:05:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002128 V 16:05:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002128 (V, A, ohm, ...), Measured Value = 0.159563 (C, atm, Hz, ...) 16:05:36 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001184 V 16:05:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001184 (V, A, ohm, ...), Measured Value = -0.000201 (C, atm, Hz, ...) 16:05:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.17 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.51 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:06:37 Magnet Current for MAIN, Imag = 308.0929 A Vtrans = 3.080861 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:06:37 MAIN (V) Voltage Measurement, V = 11.859750 V 16:06:38 Temperature Measurement, Probe Number = 0, T = 30.174000 C 16:06:39 Temperature Measurement, Probe Number = 1, T = 31.422000 C 16:06:39 Temperature Measurement, Probe Number = 2, T = 28.531000 C 16:06:40 Temperature Measurement, Probe Number = 3, T = 32.210000 C 16:06:40 Temperature Measurement, Probe Number = 4, T = 27.557000 C 16:06:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007174 V 16:06:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007174 (V, A, ohm, ...), Measured Value = 0.538065 (C, atm, Hz, ...) 16:06:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002144 V 16:06:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002144 (V, A, ohm, ...), Measured Value = 0.160823 (C, atm, Hz, ...) 16:06:42 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002760 V 16:06:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002760 (V, A, ohm, ...), Measured Value = -0.000469 (C, atm, Hz, ...) 16:06:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.17 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.21 P6 = Ambient, Value = 27.56 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:07:43 Magnet Current for MAIN, Imag = 308.0914 A Vtrans = 3.080846 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:07:44 MAIN (V) Voltage Measurement, V = 11.860421 V 16:07:44 Temperature Measurement, Probe Number = 0, T = 30.212000 C 16:07:45 Temperature Measurement, Probe Number = 1, T = 31.384000 C 16:07:45 Temperature Measurement, Probe Number = 2, T = 28.527000 C 16:07:46 Temperature Measurement, Probe Number = 3, T = 32.424000 C 16:07:47 Temperature Measurement, Probe Number = 4, T = 27.605000 C 16:07:47 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007306 V 16:07:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007306 (V, A, ohm, ...), Measured Value = 0.547942 (C, atm, Hz, ...) 16:07:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002182 V 16:07:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002182 (V, A, ohm, ...), Measured Value = 0.163635 (C, atm, Hz, ...) 16:07:48 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004028 V 16:07:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004028 (V, A, ohm, ...), Measured Value = -0.000684 (C, atm, Hz, ...) 16:07:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.21 P3 = Coil, Value = 31.38 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.42 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:08:49 Magnet Current for MAIN, Imag = 308.0920 A Vtrans = 3.080852 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:08:50 MAIN (V) Voltage Measurement, V = 11.860760 V 16:08:51 Temperature Measurement, Probe Number = 0, T = 30.222000 C 16:08:51 Temperature Measurement, Probe Number = 1, T = 31.421000 C 16:08:52 Temperature Measurement, Probe Number = 2, T = 28.537000 C 16:08:52 Temperature Measurement, Probe Number = 3, T = 32.390000 C 16:08:53 Temperature Measurement, Probe Number = 4, T = 27.615000 C 16:08:54 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007325 V 16:08:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007325 (V, A, ohm, ...), Measured Value = 0.549397 (C, atm, Hz, ...) 16:08:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002276 V 16:08:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002276 (V, A, ohm, ...), Measured Value = 0.170708 (C, atm, Hz, ...) 16:08:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.011934 V 16:08:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.011934 (V, A, ohm, ...), Measured Value = -0.002027 (C, atm, Hz, ...) 16:08:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.22 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.39 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:09:56 Magnet Current for MAIN, Imag = 308.0923 A Vtrans = 3.080855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:09:57 MAIN (V) Voltage Measurement, V = 11.861075 V 16:09:57 Temperature Measurement, Probe Number = 0, T = 30.237000 C 16:09:58 Temperature Measurement, Probe Number = 1, T = 31.421000 C 16:09:59 Temperature Measurement, Probe Number = 2, T = 28.537000 C 16:09:59 Temperature Measurement, Probe Number = 3, T = 32.235000 C 16:10:00 Temperature Measurement, Probe Number = 4, T = 27.603000 C 16:10:00 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007286 V 16:10:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007286 (V, A, ohm, ...), Measured Value = 0.546487 (C, atm, Hz, ...) 16:10:01 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002219 V 16:10:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002219 (V, A, ohm, ...), Measured Value = 0.166440 (C, atm, Hz, ...) 16:10:02 Sensor Voltage Measurement, Sensor Number = 2, V = -0.012760 V 16:10:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.012760 (V, A, ohm, ...), Measured Value = -0.002167 (C, atm, Hz, ...) 16:10:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.24 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.23 P6 = Ambient, Value = 27.60 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:11:03 Magnet Current for MAIN, Imag = 308.0921 A Vtrans = 3.080853 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:11:04 MAIN (V) Voltage Measurement, V = 11.861519 V 16:11:04 Temperature Measurement, Probe Number = 0, T = 30.243000 C 16:11:05 Temperature Measurement, Probe Number = 1, T = 31.409000 C 16:11:05 Temperature Measurement, Probe Number = 2, T = 28.531000 C 16:11:06 Temperature Measurement, Probe Number = 3, T = 32.178000 C 16:11:07 Temperature Measurement, Probe Number = 4, T = 27.551000 C 16:11:07 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007234 V 16:11:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007234 (V, A, ohm, ...), Measured Value = 0.542520 (C, atm, Hz, ...) 16:11:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002270 V 16:11:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002270 (V, A, ohm, ...), Measured Value = 0.170220 (C, atm, Hz, ...) 16:11:09 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001290 V 16:11:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001290 (V, A, ohm, ...), Measured Value = -0.000219 (C, atm, Hz, ...) 16:11:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.24 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.18 P6 = Ambient, Value = 27.55 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:12:09 Magnet Current for MAIN, Imag = 308.0933 A Vtrans = 3.080865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:12:10 MAIN (V) Voltage Measurement, V = 11.862216 V 16:12:11 Temperature Measurement, Probe Number = 0, T = 30.279000 C 16:12:11 Temperature Measurement, Probe Number = 1, T = 31.420000 C 16:12:12 Temperature Measurement, Probe Number = 2, T = 28.536000 C 16:12:12 Temperature Measurement, Probe Number = 3, T = 32.358000 C 16:12:13 Temperature Measurement, Probe Number = 4, T = 27.621000 C 16:12:14 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007214 V 16:12:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007214 (V, A, ohm, ...), Measured Value = 0.541065 (C, atm, Hz, ...) 16:12:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002294 V 16:12:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002294 (V, A, ohm, ...), Measured Value = 0.172065 (C, atm, Hz, ...) 16:12:15 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004225 V 16:12:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004225 (V, A, ohm, ...), Measured Value = -0.000718 (C, atm, Hz, ...) 16:12:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.28 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.36 P6 = Ambient, Value = 27.62 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:13:16 Magnet Current for MAIN, Imag = 308.0932 A Vtrans = 3.080864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:13:16 MAIN (V) Voltage Measurement, V = 11.862603 V 16:13:17 Temperature Measurement, Probe Number = 0, T = 30.297000 C 16:13:18 Temperature Measurement, Probe Number = 1, T = 31.387000 C 16:13:18 Temperature Measurement, Probe Number = 2, T = 28.525000 C 16:13:19 Temperature Measurement, Probe Number = 3, T = 32.427000 C 16:13:19 Temperature Measurement, Probe Number = 4, T = 27.633000 C 16:13:20 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007380 V 16:13:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007380 (V, A, ohm, ...), Measured Value = 0.553463 (C, atm, Hz, ...) 16:13:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002187 V 16:13:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002187 (V, A, ohm, ...), Measured Value = 0.164025 (C, atm, Hz, ...) 16:13:21 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003333 V 16:13:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003333 (V, A, ohm, ...), Measured Value = -0.000566 (C, atm, Hz, ...) 16:13:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.30 P3 = Coil, Value = 31.39 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 32.43 P6 = Ambient, Value = 27.63 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:14:22 Magnet Current for MAIN, Imag = 308.0933 A Vtrans = 3.080865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:14:23 MAIN (V) Voltage Measurement, V = 11.863241 V 16:14:23 Temperature Measurement, Probe Number = 0, T = 30.295000 C 16:14:24 Temperature Measurement, Probe Number = 1, T = 31.411000 C 16:14:25 Temperature Measurement, Probe Number = 2, T = 28.529000 C 16:14:25 Temperature Measurement, Probe Number = 3, T = 32.299000 C 16:14:26 Temperature Measurement, Probe Number = 4, T = 27.655000 C 16:14:27 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007222 V 16:14:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007222 (V, A, ohm, ...), Measured Value = 0.541650 (C, atm, Hz, ...) 16:14:27 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002366 V 16:14:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002366 (V, A, ohm, ...), Measured Value = 0.177487 (C, atm, Hz, ...) 16:14:28 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003662 V 16:14:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003662 (V, A, ohm, ...), Measured Value = -0.000622 (C, atm, Hz, ...) 16:14:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.30 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.30 P6 = Ambient, Value = 27.66 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:15:29 Magnet Current for MAIN, Imag = 308.0929 A Vtrans = 3.080861 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:15:29 MAIN (V) Voltage Measurement, V = 11.863918 V 16:15:30 Temperature Measurement, Probe Number = 0, T = 30.311000 C 16:15:31 Temperature Measurement, Probe Number = 1, T = 31.439000 C 16:15:31 Temperature Measurement, Probe Number = 2, T = 28.542000 C 16:15:32 Temperature Measurement, Probe Number = 3, T = 32.320000 C 16:15:32 Temperature Measurement, Probe Number = 4, T = 27.607000 C 16:15:33 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007280 V 16:15:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007280 (V, A, ohm, ...), Measured Value = 0.546008 (C, atm, Hz, ...) 16:15:34 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002165 V 16:15:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002165 (V, A, ohm, ...), Measured Value = 0.162375 (C, atm, Hz, ...) 16:15:34 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001725 V 16:15:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001725 (V, A, ohm, ...), Measured Value = -0.000293 (C, atm, Hz, ...) 16:15:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.31 P3 = Coil, Value = 31.44 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.32 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:16:35 Magnet Current for MAIN, Imag = 308.0941 A Vtrans = 3.080873 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:16:36 MAIN (V) Voltage Measurement, V = 11.864666 V 16:16:36 Temperature Measurement, Probe Number = 0, T = 30.315000 C 16:16:37 Temperature Measurement, Probe Number = 1, T = 31.456000 C 16:16:38 Temperature Measurement, Probe Number = 2, T = 28.547000 C 16:16:38 Temperature Measurement, Probe Number = 3, T = 32.282000 C 16:16:39 Temperature Measurement, Probe Number = 4, T = 27.623000 C 16:16:39 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007320 V 16:16:39 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007320 (V, A, ohm, ...), Measured Value = 0.549008 (C, atm, Hz, ...) 16:16:40 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002317 V 16:16:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002317 (V, A, ohm, ...), Measured Value = 0.173805 (C, atm, Hz, ...) 16:16:41 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003946 V 16:16:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003946 (V, A, ohm, ...), Measured Value = -0.000670 (C, atm, Hz, ...) 16:16:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.86 P2 = Yoke, Value = 30.32 P3 = Coil, Value = 31.46 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.62 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:17:42 Magnet Current for MAIN, Imag = 308.0927 A Vtrans = 3.080859 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:17:42 MAIN (V) Voltage Measurement, V = 11.865318 V 16:17:43 Temperature Measurement, Probe Number = 0, T = 30.341000 C 16:17:43 Temperature Measurement, Probe Number = 1, T = 31.469000 C 16:17:44 Temperature Measurement, Probe Number = 2, T = 28.542000 C 16:17:45 Temperature Measurement, Probe Number = 3, T = 32.273000 C 16:17:45 Temperature Measurement, Probe Number = 4, T = 27.670000 C 16:17:46 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007471 V 16:17:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007471 (V, A, ohm, ...), Measured Value = 0.560340 (C, atm, Hz, ...) 16:17:46 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002147 V 16:17:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002147 (V, A, ohm, ...), Measured Value = 0.161018 (C, atm, Hz, ...) 16:17:47 Sensor Voltage Measurement, Sensor Number = 2, V = -0.005584 V 16:17:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.005584 (V, A, ohm, ...), Measured Value = -0.000948 (C, atm, Hz, ...) 16:17:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.34 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.67 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:18:48 Magnet Current for MAIN, Imag = 308.0930 A Vtrans = 3.080862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:18:48 MAIN (V) Voltage Measurement, V = 11.866336 V 16:18:49 Temperature Measurement, Probe Number = 0, T = 30.342000 C 16:18:50 Temperature Measurement, Probe Number = 1, T = 31.472000 C 16:18:50 Temperature Measurement, Probe Number = 2, T = 28.547000 C 16:18:51 Temperature Measurement, Probe Number = 3, T = 32.182000 C 16:18:51 Temperature Measurement, Probe Number = 4, T = 27.620000 C 16:18:52 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007276 V 16:18:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007276 (V, A, ohm, ...), Measured Value = 0.545715 (C, atm, Hz, ...) 16:18:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002245 V 16:18:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002245 (V, A, ohm, ...), Measured Value = 0.168383 (C, atm, Hz, ...) 16:18:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003189 V 16:18:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003189 (V, A, ohm, ...), Measured Value = -0.000542 (C, atm, Hz, ...) 16:18:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.34 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.18 P6 = Ambient, Value = 27.62 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:19:54 Magnet Current for MAIN, Imag = 308.0945 A Vtrans = 3.080877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:19:55 MAIN (V) Voltage Measurement, V = 11.867617 V 16:19:56 Temperature Measurement, Probe Number = 0, T = 30.344000 C 16:19:56 Temperature Measurement, Probe Number = 1, T = 31.444000 C 16:19:57 Temperature Measurement, Probe Number = 2, T = 28.538000 C 16:19:57 Temperature Measurement, Probe Number = 3, T = 32.127000 C 16:19:58 Temperature Measurement, Probe Number = 4, T = 27.630000 C 16:19:59 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007293 V 16:19:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007293 (V, A, ohm, ...), Measured Value = 0.546975 (C, atm, Hz, ...) 16:19:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002285 V 16:19:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002285 (V, A, ohm, ...), Measured Value = 0.171382 (C, atm, Hz, ...) 16:20:00 Sensor Voltage Measurement, Sensor Number = 2, V = -0.021730 V 16:20:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.021730 (V, A, ohm, ...), Measured Value = -0.003690 (C, atm, Hz, ...) 16:20:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.34 P3 = Coil, Value = 31.44 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.13 P6 = Ambient, Value = 27.63 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:21:01 Magnet Current for MAIN, Imag = 308.0932 A Vtrans = 3.080864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:21:02 MAIN (V) Voltage Measurement, V = 11.868856 V 16:21:02 Temperature Measurement, Probe Number = 0, T = 30.358000 C 16:21:03 Temperature Measurement, Probe Number = 1, T = 31.436000 C 16:21:04 Temperature Measurement, Probe Number = 2, T = 28.539000 C 16:21:04 Temperature Measurement, Probe Number = 3, T = 32.108000 C 16:21:05 Temperature Measurement, Probe Number = 4, T = 27.606000 C 16:21:05 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007350 V 16:21:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007350 (V, A, ohm, ...), Measured Value = 0.551235 (C, atm, Hz, ...) 16:21:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002219 V 16:21:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002219 (V, A, ohm, ...), Measured Value = 0.166440 (C, atm, Hz, ...) 16:21:07 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002433 V 16:21:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002433 (V, A, ohm, ...), Measured Value = -0.000413 (C, atm, Hz, ...) 16:21:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.36 P3 = Coil, Value = 31.44 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.11 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:22:08 Magnet Current for MAIN, Imag = 308.0945 A Vtrans = 3.080877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:22:08 MAIN (V) Voltage Measurement, V = 11.871004 V 16:22:09 Temperature Measurement, Probe Number = 0, T = 30.370000 C 16:22:09 Temperature Measurement, Probe Number = 1, T = 31.428000 C 16:22:10 Temperature Measurement, Probe Number = 2, T = 28.549000 C 16:22:11 Temperature Measurement, Probe Number = 3, T = 32.181000 C 16:22:11 Temperature Measurement, Probe Number = 4, T = 27.593000 C 16:22:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007348 V 16:22:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007348 (V, A, ohm, ...), Measured Value = 0.551137 (C, atm, Hz, ...) 16:22:13 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002304 V 16:22:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002304 (V, A, ohm, ...), Measured Value = 0.172837 (C, atm, Hz, ...) 16:22:13 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003196 V 16:22:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003196 (V, A, ohm, ...), Measured Value = -0.000543 (C, atm, Hz, ...) 16:22:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.37 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.18 P6 = Ambient, Value = 27.59 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:23:14 Magnet Current for MAIN, Imag = 308.0934 A Vtrans = 3.080866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:23:15 MAIN (V) Voltage Measurement, V = 11.873907 V 16:23:15 Temperature Measurement, Probe Number = 0, T = 30.406000 C 16:23:16 Temperature Measurement, Probe Number = 1, T = 31.445000 C 16:23:16 Temperature Measurement, Probe Number = 2, T = 28.543000 C 16:23:17 Temperature Measurement, Probe Number = 3, T = 32.245000 C 16:23:18 Temperature Measurement, Probe Number = 4, T = 27.662000 C 16:23:18 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007285 V 16:23:18 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007285 (V, A, ohm, ...), Measured Value = 0.546390 (C, atm, Hz, ...) 16:23:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002306 V 16:23:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002306 (V, A, ohm, ...), Measured Value = 0.172935 (C, atm, Hz, ...) 16:23:19 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003400 V 16:23:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003400 (V, A, ohm, ...), Measured Value = -0.000577 (C, atm, Hz, ...) 16:23:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.87 P2 = Yoke, Value = 30.41 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.24 P6 = Ambient, Value = 27.66 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:24:20 Magnet Current for MAIN, Imag = 308.0938 A Vtrans = 3.080870 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:24:21 MAIN (V) Voltage Measurement, V = 11.878119 V 16:24:22 Temperature Measurement, Probe Number = 0, T = 30.422000 C 16:24:22 Temperature Measurement, Probe Number = 1, T = 31.462000 C 16:24:23 Temperature Measurement, Probe Number = 2, T = 28.541000 C 16:24:23 Temperature Measurement, Probe Number = 3, T = 32.202000 C 16:24:24 Temperature Measurement, Probe Number = 4, T = 27.613000 C 16:24:25 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007311 V 16:24:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007311 (V, A, ohm, ...), Measured Value = 0.548332 (C, atm, Hz, ...) 16:24:25 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002237 V 16:24:25 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002237 (V, A, ohm, ...), Measured Value = 0.167797 (C, atm, Hz, ...) 16:24:26 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001145 V 16:24:26 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001145 (V, A, ohm, ...), Measured Value = -0.000194 (C, atm, Hz, ...) 16:24:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.88 P2 = Yoke, Value = 30.42 P3 = Coil, Value = 31.46 P4 = H20_In, Value = 28.54 P5 = H2O_Out, Value = 32.20 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:25:27 Magnet Current for MAIN, Imag = 308.0937 A Vtrans = 3.080869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:25:27 MAIN (V) Voltage Measurement, V = 11.884918 V 16:25:28 Temperature Measurement, Probe Number = 0, T = 30.425000 C 16:25:29 Temperature Measurement, Probe Number = 1, T = 31.472000 C 16:25:29 Temperature Measurement, Probe Number = 2, T = 28.532000 C 16:25:30 Temperature Measurement, Probe Number = 3, T = 32.261000 C 16:25:31 Temperature Measurement, Probe Number = 4, T = 27.669000 C 16:25:31 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007345 V 16:25:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007345 (V, A, ohm, ...), Measured Value = 0.550852 (C, atm, Hz, ...) 16:25:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002151 V 16:25:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002151 (V, A, ohm, ...), Measured Value = 0.161310 (C, atm, Hz, ...) 16:25:32 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002095 V 16:25:32 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002095 (V, A, ohm, ...), Measured Value = -0.000356 (C, atm, Hz, ...) 16:25:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.88 P2 = Yoke, Value = 30.43 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.26 P6 = Ambient, Value = 27.67 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 16:26:33 Magnet Current for MAIN, Imag = 308.0937 A Vtrans = 3.080869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:26:34 MAIN (V) Voltage Measurement, V = 11.898188 V 16:26:34 Temperature Measurement, Probe Number = 0, T = 30.426000 C 16:26:35 Temperature Measurement, Probe Number = 1, T = 31.460000 C 16:26:36 Temperature Measurement, Probe Number = 2, T = 28.533000 C 16:26:36 Temperature Measurement, Probe Number = 3, T = 32.212000 C 16:26:37 Temperature Measurement, Probe Number = 4, T = 27.662000 C 16:26:38 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007404 V 16:26:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007404 (V, A, ohm, ...), Measured Value = 0.555308 (C, atm, Hz, ...) 16:26:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002231 V 16:26:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002231 (V, A, ohm, ...), Measured Value = 0.167318 (C, atm, Hz, ...) 16:26:39 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001257 V 16:26:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001257 (V, A, ohm, ...), Measured Value = -0.000213 (C, atm, Hz, ...) 16:26:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.90 P2 = Yoke, Value = 30.43 P3 = Coil, Value = 31.46 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 32.21 P6 = Ambient, Value = 27.66 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:27:40 Magnet Current for MAIN, Imag = 308.0918 A Vtrans = 3.080849 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:27:40 MAIN (V) Voltage Measurement, V = 11.921189 V 16:27:41 Temperature Measurement, Probe Number = 0, T = 30.448000 C 16:27:42 Temperature Measurement, Probe Number = 1, T = 31.474000 C 16:27:42 Temperature Measurement, Probe Number = 2, T = 28.551000 C 16:27:43 Temperature Measurement, Probe Number = 3, T = 32.297000 C 16:27:44 Temperature Measurement, Probe Number = 4, T = 27.633000 C 16:27:44 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007436 V 16:27:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007436 (V, A, ohm, ...), Measured Value = 0.557730 (C, atm, Hz, ...) 16:27:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002372 V 16:27:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002372 (V, A, ohm, ...), Measured Value = 0.177878 (C, atm, Hz, ...) 16:27:45 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003206 V 16:27:45 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003206 (V, A, ohm, ...), Measured Value = -0.000545 (C, atm, Hz, ...) 16:27:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.92 P2 = Yoke, Value = 30.45 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.30 P6 = Ambient, Value = 27.63 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:28:46 Magnet Current for MAIN, Imag = 308.0911 A Vtrans = 3.080843 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:28:47 MAIN (V) Voltage Measurement, V = 11.964868 V 16:28:47 Temperature Measurement, Probe Number = 0, T = 30.468000 C 16:28:48 Temperature Measurement, Probe Number = 1, T = 31.480000 C 16:28:49 Temperature Measurement, Probe Number = 2, T = 28.563000 C 16:28:49 Temperature Measurement, Probe Number = 3, T = 32.317000 C 16:28:50 Temperature Measurement, Probe Number = 4, T = 27.703000 C 16:28:50 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007370 V 16:28:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007370 (V, A, ohm, ...), Measured Value = 0.552787 (C, atm, Hz, ...) 16:28:51 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002510 V 16:28:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002510 (V, A, ohm, ...), Measured Value = 0.188242 (C, atm, Hz, ...) 16:28:52 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000193 V 16:28:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000193 (V, A, ohm, ...), Measured Value = 0.000033 (C, atm, Hz, ...) 16:28:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.96 P2 = Yoke, Value = 30.47 P3 = Coil, Value = 31.48 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 32.32 P6 = Ambient, Value = 27.70 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = 0.00 16:29:53 Magnet Current for MAIN, Imag = 308.0932 A Vtrans = 3.080864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:29:53 MAIN (V) Voltage Measurement, V = 11.984114 V 16:29:54 Temperature Measurement, Probe Number = 0, T = 30.479000 C 16:29:54 Temperature Measurement, Probe Number = 1, T = 31.469000 C 16:29:55 Temperature Measurement, Probe Number = 2, T = 28.559000 C 16:29:56 Temperature Measurement, Probe Number = 3, T = 32.233000 C 16:29:56 Temperature Measurement, Probe Number = 4, T = 27.674000 C 16:29:57 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007383 V 16:29:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007383 (V, A, ohm, ...), Measured Value = 0.553755 (C, atm, Hz, ...) 16:29:57 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002448 V 16:29:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002448 (V, A, ohm, ...), Measured Value = 0.183592 (C, atm, Hz, ...) 16:29:58 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001234 V 16:29:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001234 (V, A, ohm, ...), Measured Value = -0.000210 (C, atm, Hz, ...) 16:29:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.48 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 32.23 P6 = Ambient, Value = 27.67 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:30:59 Magnet Current for MAIN, Imag = 308.0933 A Vtrans = 3.080865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:31:00 MAIN (V) Voltage Measurement, V = 11.981222 V 16:31:00 Temperature Measurement, Probe Number = 0, T = 30.470000 C 16:31:01 Temperature Measurement, Probe Number = 1, T = 31.453000 C 16:31:01 Temperature Measurement, Probe Number = 2, T = 28.545000 C 16:31:02 Temperature Measurement, Probe Number = 3, T = 32.133000 C 16:31:03 Temperature Measurement, Probe Number = 4, T = 27.634000 C 16:31:03 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007345 V 16:31:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007345 (V, A, ohm, ...), Measured Value = 0.550852 (C, atm, Hz, ...) 16:31:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002299 V 16:31:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002299 (V, A, ohm, ...), Measured Value = 0.172448 (C, atm, Hz, ...) 16:31:05 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003727 V 16:31:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003727 (V, A, ohm, ...), Measured Value = -0.000633 (C, atm, Hz, ...) 16:31:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.47 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.13 P6 = Ambient, Value = 27.63 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:32:05 Magnet Current for MAIN, Imag = 308.0925 A Vtrans = 3.080857 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:32:06 MAIN (V) Voltage Measurement, V = 11.981993 V 16:32:07 Temperature Measurement, Probe Number = 0, T = 30.477000 C 16:32:07 Temperature Measurement, Probe Number = 1, T = 31.430000 C 16:32:08 Temperature Measurement, Probe Number = 2, T = 28.549000 C 16:32:09 Temperature Measurement, Probe Number = 3, T = 32.100000 C 16:32:09 Temperature Measurement, Probe Number = 4, T = 27.615000 C 16:32:10 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007382 V 16:32:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007382 (V, A, ohm, ...), Measured Value = 0.553658 (C, atm, Hz, ...) 16:32:10 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002390 V 16:32:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002390 (V, A, ohm, ...), Measured Value = 0.179227 (C, atm, Hz, ...) 16:32:11 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004315 V 16:32:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004315 (V, A, ohm, ...), Measured Value = -0.000733 (C, atm, Hz, ...) 16:32:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.48 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.10 P6 = Ambient, Value = 27.61 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:33:12 Magnet Current for MAIN, Imag = 308.0981 A Vtrans = 3.080913 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:33:13 MAIN (V) Voltage Measurement, V = 11.983564 V 16:33:13 Temperature Measurement, Probe Number = 0, T = 30.491000 C 16:33:14 Temperature Measurement, Probe Number = 1, T = 31.424000 C 16:33:14 Temperature Measurement, Probe Number = 2, T = 28.555000 C 16:33:15 Temperature Measurement, Probe Number = 3, T = 32.095000 C 16:33:16 Temperature Measurement, Probe Number = 4, T = 27.603000 C 16:33:16 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007541 V 16:33:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007541 (V, A, ohm, ...), Measured Value = 0.565575 (C, atm, Hz, ...) 16:33:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002254 V 16:33:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002254 (V, A, ohm, ...), Measured Value = 0.169058 (C, atm, Hz, ...) 16:33:17 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002026 V 16:33:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002026 (V, A, ohm, ...), Measured Value = -0.000344 (C, atm, Hz, ...) 16:33:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.49 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.09 P6 = Ambient, Value = 27.60 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:34:18 Magnet Current for MAIN, Imag = 308.0933 A Vtrans = 3.080865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:34:19 MAIN (V) Voltage Measurement, V = 11.979176 V 16:34:20 Temperature Measurement, Probe Number = 0, T = 30.495000 C 16:34:20 Temperature Measurement, Probe Number = 1, T = 31.428000 C 16:34:21 Temperature Measurement, Probe Number = 2, T = 28.554000 C 16:34:21 Temperature Measurement, Probe Number = 3, T = 32.029000 C 16:34:22 Temperature Measurement, Probe Number = 4, T = 27.587000 C 16:34:23 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007439 V 16:34:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007439 (V, A, ohm, ...), Measured Value = 0.557925 (C, atm, Hz, ...) 16:34:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002364 V 16:34:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002364 (V, A, ohm, ...), Measured Value = 0.177292 (C, atm, Hz, ...) 16:34:24 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004136 V 16:34:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004136 (V, A, ohm, ...), Measured Value = -0.000702 (C, atm, Hz, ...) 16:34:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.50 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.03 P6 = Ambient, Value = 27.59 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:35:25 Magnet Current for MAIN, Imag = 308.0968 A Vtrans = 3.080900 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:35:25 MAIN (V) Voltage Measurement, V = 11.979216 V 16:35:26 Temperature Measurement, Probe Number = 0, T = 30.523000 C 16:35:26 Temperature Measurement, Probe Number = 1, T = 31.429000 C 16:35:27 Temperature Measurement, Probe Number = 2, T = 28.555000 C 16:35:28 Temperature Measurement, Probe Number = 3, T = 32.028000 C 16:35:28 Temperature Measurement, Probe Number = 4, T = 27.562000 C 16:35:29 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007465 V 16:35:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007465 (V, A, ohm, ...), Measured Value = 0.559860 (C, atm, Hz, ...) 16:35:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002435 V 16:35:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002435 (V, A, ohm, ...), Measured Value = 0.182625 (C, atm, Hz, ...) 16:35:30 Sensor Voltage Measurement, Sensor Number = 2, V = -0.010421 V 16:35:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.010421 (V, A, ohm, ...), Measured Value = -0.001770 (C, atm, Hz, ...) 16:35:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.52 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.03 P6 = Ambient, Value = 27.56 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:36:31 Magnet Current for MAIN, Imag = 308.0987 A Vtrans = 3.080919 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:36:32 MAIN (V) Voltage Measurement, V = 11.977101 V 16:36:33 Temperature Measurement, Probe Number = 0, T = 30.538000 C 16:36:33 Temperature Measurement, Probe Number = 1, T = 31.416000 C 16:36:34 Temperature Measurement, Probe Number = 2, T = 28.559000 C 16:36:34 Temperature Measurement, Probe Number = 3, T = 32.174000 C 16:36:35 Temperature Measurement, Probe Number = 4, T = 27.636000 C 16:36:36 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007475 V 16:36:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007475 (V, A, ohm, ...), Measured Value = 0.560632 (C, atm, Hz, ...) 16:36:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002435 V 16:36:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002435 (V, A, ohm, ...), Measured Value = 0.182625 (C, atm, Hz, ...) 16:36:37 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001593 V 16:36:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001593 (V, A, ohm, ...), Measured Value = -0.000271 (C, atm, Hz, ...) 16:36:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.54 P3 = Coil, Value = 31.42 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 32.17 P6 = Ambient, Value = 27.64 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:37:38 Magnet Current for MAIN, Imag = 308.0929 A Vtrans = 3.080861 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:37:38 MAIN (V) Voltage Measurement, V = 11.977340 V 16:37:39 Temperature Measurement, Probe Number = 0, T = 30.568000 C 16:37:40 Temperature Measurement, Probe Number = 1, T = 31.433000 C 16:37:40 Temperature Measurement, Probe Number = 2, T = 28.551000 C 16:37:41 Temperature Measurement, Probe Number = 3, T = 32.261000 C 16:37:41 Temperature Measurement, Probe Number = 4, T = 27.701000 C 16:37:42 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007442 V 16:37:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007442 (V, A, ohm, ...), Measured Value = 0.558113 (C, atm, Hz, ...) 16:37:43 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002396 V 16:37:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002396 (V, A, ohm, ...), Measured Value = 0.179715 (C, atm, Hz, ...) 16:37:43 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003278 V 16:37:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003278 (V, A, ohm, ...), Measured Value = -0.000557 (C, atm, Hz, ...) 16:37:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.57 P3 = Coil, Value = 31.43 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.26 P6 = Ambient, Value = 27.70 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:38:44 Magnet Current for MAIN, Imag = 308.1000 A Vtrans = 3.080932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:38:45 MAIN (V) Voltage Measurement, V = 11.975312 V 16:38:45 Temperature Measurement, Probe Number = 0, T = 30.570000 C 16:38:46 Temperature Measurement, Probe Number = 1, T = 31.471000 C 16:38:47 Temperature Measurement, Probe Number = 2, T = 28.549000 C 16:38:47 Temperature Measurement, Probe Number = 3, T = 32.274000 C 16:38:48 Temperature Measurement, Probe Number = 4, T = 27.733000 C 16:38:48 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007390 V 16:38:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007390 (V, A, ohm, ...), Measured Value = 0.554242 (C, atm, Hz, ...) 16:38:49 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002383 V 16:38:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002383 (V, A, ohm, ...), Measured Value = 0.178747 (C, atm, Hz, ...) 16:38:50 Sensor Voltage Measurement, Sensor Number = 2, V = -0.007054 V 16:38:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.007054 (V, A, ohm, ...), Measured Value = -0.001198 (C, atm, Hz, ...) 16:38:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.57 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.73 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:39:51 Magnet Current for MAIN, Imag = 308.0928 A Vtrans = 3.080860 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:39:51 MAIN (V) Voltage Measurement, V = 11.977184 V 16:39:52 Temperature Measurement, Probe Number = 0, T = 30.584000 C 16:39:53 Temperature Measurement, Probe Number = 1, T = 31.474000 C 16:39:53 Temperature Measurement, Probe Number = 2, T = 28.548000 C 16:39:54 Temperature Measurement, Probe Number = 3, T = 32.266000 C 16:39:54 Temperature Measurement, Probe Number = 4, T = 27.791000 C 16:39:55 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007451 V 16:39:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007451 (V, A, ohm, ...), Measured Value = 0.558795 (C, atm, Hz, ...) 16:39:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002304 V 16:39:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002304 (V, A, ohm, ...), Measured Value = 0.172837 (C, atm, Hz, ...) 16:39:56 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000914 V 16:39:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000914 (V, A, ohm, ...), Measured Value = -0.000155 (C, atm, Hz, ...) 16:39:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.58 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:40:57 Magnet Current for MAIN, Imag = 308.1016 A Vtrans = 3.080948 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:40:58 MAIN (V) Voltage Measurement, V = 11.975689 V 16:40:58 Temperature Measurement, Probe Number = 0, T = 30.592000 C 16:40:59 Temperature Measurement, Probe Number = 1, T = 31.485000 C 16:41:00 Temperature Measurement, Probe Number = 2, T = 28.558000 C 16:41:00 Temperature Measurement, Probe Number = 3, T = 32.216000 C 16:41:01 Temperature Measurement, Probe Number = 4, T = 27.765000 C 16:41:02 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007545 V 16:41:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007545 (V, A, ohm, ...), Measured Value = 0.565868 (C, atm, Hz, ...) 16:41:02 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002498 V 16:41:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002498 (V, A, ohm, ...), Measured Value = 0.187365 (C, atm, Hz, ...) 16:41:03 Sensor Voltage Measurement, Sensor Number = 2, V = -0.018021 V 16:41:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.018021 (V, A, ohm, ...), Measured Value = -0.003061 (C, atm, Hz, ...) 16:41:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.59 P3 = Coil, Value = 31.48 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 32.22 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:42:04 Magnet Current for MAIN, Imag = 308.0889 A Vtrans = 3.080821 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:42:05 MAIN (V) Voltage Measurement, V = 11.980739 V 16:42:05 Temperature Measurement, Probe Number = 0, T = 30.607000 C 16:42:06 Temperature Measurement, Probe Number = 1, T = 31.506000 C 16:42:06 Temperature Measurement, Probe Number = 2, T = 28.561000 C 16:42:07 Temperature Measurement, Probe Number = 3, T = 32.269000 C 16:42:08 Temperature Measurement, Probe Number = 4, T = 27.739000 C 16:42:08 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007442 V 16:42:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007442 (V, A, ohm, ...), Measured Value = 0.558113 (C, atm, Hz, ...) 16:42:09 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002435 V 16:42:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002435 (V, A, ohm, ...), Measured Value = 0.182625 (C, atm, Hz, ...) 16:42:10 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001208 V 16:42:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001208 (V, A, ohm, ...), Measured Value = -0.000205 (C, atm, Hz, ...) 16:42:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.61 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.74 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:43:10 Magnet Current for MAIN, Imag = 308.1025 A Vtrans = 3.080957 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:43:11 MAIN (V) Voltage Measurement, V = 11.977442 V 16:43:12 Temperature Measurement, Probe Number = 0, T = 30.618000 C 16:43:12 Temperature Measurement, Probe Number = 1, T = 31.505000 C 16:43:13 Temperature Measurement, Probe Number = 2, T = 28.565000 C 16:43:14 Temperature Measurement, Probe Number = 3, T = 32.273000 C 16:43:14 Temperature Measurement, Probe Number = 4, T = 27.780000 C 16:43:15 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007469 V 16:43:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007469 (V, A, ohm, ...), Measured Value = 0.560152 (C, atm, Hz, ...) 16:43:15 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002308 V 16:43:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002308 (V, A, ohm, ...), Measured Value = 0.173130 (C, atm, Hz, ...) 16:43:16 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002669 V 16:43:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002669 (V, A, ohm, ...), Measured Value = -0.000453 (C, atm, Hz, ...) 16:43:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.62 P3 = Coil, Value = 31.50 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.78 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 16:44:17 Magnet Current for MAIN, Imag = 308.0901 A Vtrans = 3.080833 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:44:18 MAIN (V) Voltage Measurement, V = 11.979425 V 16:44:18 Temperature Measurement, Probe Number = 0, T = 30.631000 C 16:44:19 Temperature Measurement, Probe Number = 1, T = 31.517000 C 16:44:20 Temperature Measurement, Probe Number = 2, T = 28.575000 C 16:44:20 Temperature Measurement, Probe Number = 3, T = 32.332000 C 16:44:21 Temperature Measurement, Probe Number = 4, T = 27.800000 C 16:44:21 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007555 V 16:44:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007555 (V, A, ohm, ...), Measured Value = 0.566640 (C, atm, Hz, ...) 16:44:22 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002525 V 16:44:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002525 (V, A, ohm, ...), Measured Value = 0.189405 (C, atm, Hz, ...) 16:44:23 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001840 V 16:44:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001840 (V, A, ohm, ...), Measured Value = -0.000312 (C, atm, Hz, ...) 16:44:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.63 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.33 P6 = Ambient, Value = 27.80 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:45:23 Magnet Current for MAIN, Imag = 308.0916 A Vtrans = 3.080848 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:45:24 MAIN (V) Voltage Measurement, V = 11.982247 V 16:45:25 Temperature Measurement, Probe Number = 0, T = 30.637000 C 16:45:25 Temperature Measurement, Probe Number = 1, T = 31.511000 C 16:45:26 Temperature Measurement, Probe Number = 2, T = 28.580000 C 16:45:27 Temperature Measurement, Probe Number = 3, T = 32.371000 C 16:45:27 Temperature Measurement, Probe Number = 4, T = 27.773000 C 16:45:28 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007509 V 16:45:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007509 (V, A, ohm, ...), Measured Value = 0.563153 (C, atm, Hz, ...) 16:45:28 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002456 V 16:45:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002456 (V, A, ohm, ...), Measured Value = 0.184170 (C, atm, Hz, ...) 16:45:29 Sensor Voltage Measurement, Sensor Number = 2, V = -0.016278 V 16:45:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.016278 (V, A, ohm, ...), Measured Value = -0.002765 (C, atm, Hz, ...) 16:45:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.64 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.37 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:46:30 Magnet Current for MAIN, Imag = 308.0982 A Vtrans = 3.080914 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:46:31 MAIN (V) Voltage Measurement, V = 11.980635 V 16:46:31 Temperature Measurement, Probe Number = 0, T = 30.651000 C 16:46:32 Temperature Measurement, Probe Number = 1, T = 31.507000 C 16:46:33 Temperature Measurement, Probe Number = 2, T = 28.584000 C 16:46:33 Temperature Measurement, Probe Number = 3, T = 32.355000 C 16:46:34 Temperature Measurement, Probe Number = 4, T = 27.819000 C 16:46:34 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007448 V 16:46:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007448 (V, A, ohm, ...), Measured Value = 0.558600 (C, atm, Hz, ...) 16:46:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002529 V 16:46:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002529 (V, A, ohm, ...), Measured Value = 0.189690 (C, atm, Hz, ...) 16:46:36 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002559 V 16:46:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002559 (V, A, ohm, ...), Measured Value = -0.000435 (C, atm, Hz, ...) 16:46:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.65 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.35 P6 = Ambient, Value = 27.82 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:47:37 Magnet Current for MAIN, Imag = 308.0875 A Vtrans = 3.080807 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:47:37 MAIN (V) Voltage Measurement, V = 11.982778 V 16:47:38 Temperature Measurement, Probe Number = 0, T = 30.661000 C 16:47:38 Temperature Measurement, Probe Number = 1, T = 31.521000 C 16:47:39 Temperature Measurement, Probe Number = 2, T = 28.583000 C 16:47:40 Temperature Measurement, Probe Number = 3, T = 32.311000 C 16:47:40 Temperature Measurement, Probe Number = 4, T = 27.813000 C 16:47:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007565 V 16:47:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007565 (V, A, ohm, ...), Measured Value = 0.567412 (C, atm, Hz, ...) 16:47:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002434 V 16:47:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002434 (V, A, ohm, ...), Measured Value = 0.182528 (C, atm, Hz, ...) 16:47:42 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000588 V 16:47:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000588 (V, A, ohm, ...), Measured Value = -0.000100 (C, atm, Hz, ...) 16:47:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.66 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.31 P6 = Ambient, Value = 27.81 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:48:43 Magnet Current for MAIN, Imag = 308.1026 A Vtrans = 3.080958 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:48:43 MAIN (V) Voltage Measurement, V = 11.977463 V 16:48:44 Temperature Measurement, Probe Number = 0, T = 30.670000 C 16:48:45 Temperature Measurement, Probe Number = 1, T = 31.543000 C 16:48:45 Temperature Measurement, Probe Number = 2, T = 28.589000 C 16:48:46 Temperature Measurement, Probe Number = 3, T = 32.335000 C 16:48:47 Temperature Measurement, Probe Number = 4, T = 27.793000 C 16:48:47 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007467 V 16:48:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007467 (V, A, ohm, ...), Measured Value = 0.560055 (C, atm, Hz, ...) 16:48:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002450 V 16:48:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002450 (V, A, ohm, ...), Measured Value = 0.183787 (C, atm, Hz, ...) 16:48:48 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001177 V 16:48:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001177 (V, A, ohm, ...), Measured Value = -0.000200 (C, atm, Hz, ...) 16:48:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.67 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.34 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:49:49 Magnet Current for MAIN, Imag = 308.1005 A Vtrans = 3.080937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:49:50 MAIN (V) Voltage Measurement, V = 11.978784 V 16:49:50 Temperature Measurement, Probe Number = 0, T = 30.687000 C 16:49:51 Temperature Measurement, Probe Number = 1, T = 31.566000 C 16:49:52 Temperature Measurement, Probe Number = 2, T = 28.593000 C 16:49:52 Temperature Measurement, Probe Number = 3, T = 32.400000 C 16:49:53 Temperature Measurement, Probe Number = 4, T = 27.785000 C 16:49:54 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007590 V 16:49:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007590 (V, A, ohm, ...), Measured Value = 0.569258 (C, atm, Hz, ...) 16:49:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002629 V 16:49:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002629 (V, A, ohm, ...), Measured Value = 0.197153 (C, atm, Hz, ...) 16:49:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.018296 V 16:49:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.018296 (V, A, ohm, ...), Measured Value = -0.003107 (C, atm, Hz, ...) 16:49:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.69 P3 = Coil, Value = 31.57 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.40 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 16:50:56 Magnet Current for MAIN, Imag = 308.0915 A Vtrans = 3.080847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:50:57 MAIN (V) Voltage Measurement, V = 11.980808 V 16:50:57 Temperature Measurement, Probe Number = 0, T = 30.691000 C 16:50:58 Temperature Measurement, Probe Number = 1, T = 31.584000 C 16:50:59 Temperature Measurement, Probe Number = 2, T = 28.592000 C 16:50:59 Temperature Measurement, Probe Number = 3, T = 32.378000 C 16:51:00 Temperature Measurement, Probe Number = 4, T = 27.801000 C 16:51:00 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007576 V 16:51:00 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007576 (V, A, ohm, ...), Measured Value = 0.568192 (C, atm, Hz, ...) 16:51:01 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002581 V 16:51:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002581 (V, A, ohm, ...), Measured Value = 0.193568 (C, atm, Hz, ...) 16:51:02 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001984 V 16:51:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001984 (V, A, ohm, ...), Measured Value = -0.000337 (C, atm, Hz, ...) 16:51:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.69 P3 = Coil, Value = 31.58 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.38 P6 = Ambient, Value = 27.80 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:52:03 Magnet Current for MAIN, Imag = 308.0943 A Vtrans = 3.080875 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:52:03 MAIN (V) Voltage Measurement, V = 11.981642 V 16:52:04 Temperature Measurement, Probe Number = 0, T = 30.692000 C 16:52:05 Temperature Measurement, Probe Number = 1, T = 31.566000 C 16:52:05 Temperature Measurement, Probe Number = 2, T = 28.589000 C 16:52:06 Temperature Measurement, Probe Number = 3, T = 32.356000 C 16:52:06 Temperature Measurement, Probe Number = 4, T = 27.817000 C 16:52:07 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007501 V 16:52:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007501 (V, A, ohm, ...), Measured Value = 0.562575 (C, atm, Hz, ...) 16:52:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002639 V 16:52:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002639 (V, A, ohm, ...), Measured Value = 0.197925 (C, atm, Hz, ...) 16:52:08 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000531 V 16:52:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000531 (V, A, ohm, ...), Measured Value = 0.000090 (C, atm, Hz, ...) 16:52:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.69 P3 = Coil, Value = 31.57 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.36 P6 = Ambient, Value = 27.82 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 16:53:09 Magnet Current for MAIN, Imag = 308.0912 A Vtrans = 3.080844 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:53:10 MAIN (V) Voltage Measurement, V = 11.976506 V 16:53:10 Temperature Measurement, Probe Number = 0, T = 30.693000 C 16:53:11 Temperature Measurement, Probe Number = 1, T = 31.540000 C 16:53:12 Temperature Measurement, Probe Number = 2, T = 28.579000 C 16:53:12 Temperature Measurement, Probe Number = 3, T = 32.297000 C 16:53:13 Temperature Measurement, Probe Number = 4, T = 27.785000 C 16:53:14 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007417 V 16:53:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007417 (V, A, ohm, ...), Measured Value = 0.556275 (C, atm, Hz, ...) 16:53:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002607 V 16:53:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002607 (V, A, ohm, ...), Measured Value = 0.195510 (C, atm, Hz, ...) 16:53:15 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000032 V 16:53:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000032 (V, A, ohm, ...), Measured Value = 0.000005 (C, atm, Hz, ...) 16:53:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.69 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.30 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 16:54:16 Magnet Current for MAIN, Imag = 308.1044 A Vtrans = 3.080976 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:54:16 MAIN (V) Voltage Measurement, V = 11.978436 V 16:54:17 Temperature Measurement, Probe Number = 0, T = 30.714000 C 16:54:18 Temperature Measurement, Probe Number = 1, T = 31.527000 C 16:54:18 Temperature Measurement, Probe Number = 2, T = 28.576000 C 16:54:19 Temperature Measurement, Probe Number = 3, T = 32.304000 C 16:54:20 Temperature Measurement, Probe Number = 4, T = 27.762000 C 16:54:20 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007546 V 16:54:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007546 (V, A, ohm, ...), Measured Value = 0.565965 (C, atm, Hz, ...) 16:54:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002432 V 16:54:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002432 (V, A, ohm, ...), Measured Value = 0.182430 (C, atm, Hz, ...) 16:54:21 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003126 V 16:54:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003126 (V, A, ohm, ...), Measured Value = -0.000531 (C, atm, Hz, ...) 16:54:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.71 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.30 P6 = Ambient, Value = 27.76 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 16:55:22 Magnet Current for MAIN, Imag = 308.0907 A Vtrans = 3.080839 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:55:23 MAIN (V) Voltage Measurement, V = 11.977822 V 16:55:24 Temperature Measurement, Probe Number = 0, T = 30.723000 C 16:55:24 Temperature Measurement, Probe Number = 1, T = 31.520000 C 16:55:25 Temperature Measurement, Probe Number = 2, T = 28.575000 C 16:55:25 Temperature Measurement, Probe Number = 3, T = 32.319000 C 16:55:26 Temperature Measurement, Probe Number = 4, T = 27.787000 C 16:55:27 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007511 V 16:55:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007511 (V, A, ohm, ...), Measured Value = 0.563347 (C, atm, Hz, ...) 16:55:27 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002554 V 16:55:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002554 (V, A, ohm, ...), Measured Value = 0.191535 (C, atm, Hz, ...) 16:55:28 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002374 V 16:55:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002374 (V, A, ohm, ...), Measured Value = -0.000403 (C, atm, Hz, ...) 16:55:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.72 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.32 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:56:29 Magnet Current for MAIN, Imag = 308.1008 A Vtrans = 3.080940 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:56:29 MAIN (V) Voltage Measurement, V = 11.979189 V 16:56:30 Temperature Measurement, Probe Number = 0, T = 30.724000 C 16:56:31 Temperature Measurement, Probe Number = 1, T = 31.524000 C 16:56:31 Temperature Measurement, Probe Number = 2, T = 28.581000 C 16:56:32 Temperature Measurement, Probe Number = 3, T = 32.334000 C 16:56:32 Temperature Measurement, Probe Number = 4, T = 27.831000 C 16:56:33 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007544 V 16:56:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007544 (V, A, ohm, ...), Measured Value = 0.565770 (C, atm, Hz, ...) 16:56:34 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002595 V 16:56:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002595 (V, A, ohm, ...), Measured Value = 0.194632 (C, atm, Hz, ...) 16:56:34 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003735 V 16:56:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003735 (V, A, ohm, ...), Measured Value = -0.000634 (C, atm, Hz, ...) 16:56:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.72 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.33 P6 = Ambient, Value = 27.83 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:57:35 Magnet Current for MAIN, Imag = 308.0960 A Vtrans = 3.080892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:57:36 MAIN (V) Voltage Measurement, V = 11.980824 V 16:57:36 Temperature Measurement, Probe Number = 0, T = 30.729000 C 16:57:37 Temperature Measurement, Probe Number = 1, T = 31.527000 C 16:57:38 Temperature Measurement, Probe Number = 2, T = 28.582000 C 16:57:38 Temperature Measurement, Probe Number = 3, T = 32.262000 C 16:57:39 Temperature Measurement, Probe Number = 4, T = 27.833000 C 16:57:40 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007489 V 16:57:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007489 (V, A, ohm, ...), Measured Value = 0.561698 (C, atm, Hz, ...) 16:57:40 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002538 V 16:57:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002538 (V, A, ohm, ...), Measured Value = 0.190373 (C, atm, Hz, ...) 16:57:41 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001220 V 16:57:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001220 (V, A, ohm, ...), Measured Value = -0.000207 (C, atm, Hz, ...) 16:57:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.73 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.26 P6 = Ambient, Value = 27.83 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 16:58:42 Magnet Current for MAIN, Imag = 308.0956 A Vtrans = 3.080888 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:58:42 MAIN (V) Voltage Measurement, V = 11.976395 V 16:58:43 Temperature Measurement, Probe Number = 0, T = 30.735000 C 16:58:44 Temperature Measurement, Probe Number = 1, T = 31.509000 C 16:58:44 Temperature Measurement, Probe Number = 2, T = 28.578000 C 16:58:45 Temperature Measurement, Probe Number = 3, T = 32.246000 C 16:58:45 Temperature Measurement, Probe Number = 4, T = 27.769000 C 16:58:46 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007575 V 16:58:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007575 (V, A, ohm, ...), Measured Value = 0.568095 (C, atm, Hz, ...) 16:58:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002403 V 16:58:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002403 (V, A, ohm, ...), Measured Value = 0.180202 (C, atm, Hz, ...) 16:58:47 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000396 V 16:58:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000396 (V, A, ohm, ...), Measured Value = 0.000067 (C, atm, Hz, ...) 16:58:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.73 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.25 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = 0.00 16:59:48 Magnet Current for MAIN, Imag = 308.0994 A Vtrans = 3.080926 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 16:59:49 MAIN (V) Voltage Measurement, V = 11.980137 V 16:59:49 Temperature Measurement, Probe Number = 0, T = 30.738000 C 16:59:50 Temperature Measurement, Probe Number = 1, T = 31.496000 C 16:59:51 Temperature Measurement, Probe Number = 2, T = 28.582000 C 16:59:51 Temperature Measurement, Probe Number = 3, T = 32.272000 C 16:59:52 Temperature Measurement, Probe Number = 4, T = 27.760000 C 16:59:52 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007519 V 16:59:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007519 (V, A, ohm, ...), Measured Value = 0.563925 (C, atm, Hz, ...) 16:59:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002524 V 16:59:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002524 (V, A, ohm, ...), Measured Value = 0.189308 (C, atm, Hz, ...) 16:59:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.014218 V 16:59:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.014218 (V, A, ohm, ...), Measured Value = -0.002415 (C, atm, Hz, ...) 16:59:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.74 P3 = Coil, Value = 31.50 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.76 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:00:55 Magnet Current for MAIN, Imag = 308.0959 A Vtrans = 3.080891 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:00:55 MAIN (V) Voltage Measurement, V = 11.979800 V 17:00:56 Temperature Measurement, Probe Number = 0, T = 30.761000 C 17:00:57 Temperature Measurement, Probe Number = 1, T = 31.482000 C 17:00:57 Temperature Measurement, Probe Number = 2, T = 28.586000 C 17:00:58 Temperature Measurement, Probe Number = 3, T = 32.349000 C 17:00:59 Temperature Measurement, Probe Number = 4, T = 27.724000 C 17:00:59 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007515 V 17:00:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007515 (V, A, ohm, ...), Measured Value = 0.563640 (C, atm, Hz, ...) 17:01:00 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002613 V 17:01:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002613 (V, A, ohm, ...), Measured Value = 0.195990 (C, atm, Hz, ...) 17:01:01 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001685 V 17:01:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001685 (V, A, ohm, ...), Measured Value = -0.000286 (C, atm, Hz, ...) 17:01:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.76 P3 = Coil, Value = 31.48 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.35 P6 = Ambient, Value = 27.72 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:02:02 Magnet Current for MAIN, Imag = 308.0954 A Vtrans = 3.080886 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:02:02 MAIN (V) Voltage Measurement, V = 11.978053 V 17:02:03 Temperature Measurement, Probe Number = 0, T = 30.754000 C 17:02:03 Temperature Measurement, Probe Number = 1, T = 31.485000 C 17:02:04 Temperature Measurement, Probe Number = 2, T = 28.577000 C 17:02:05 Temperature Measurement, Probe Number = 3, T = 32.267000 C 17:02:05 Temperature Measurement, Probe Number = 4, T = 27.673000 C 17:02:06 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007504 V 17:02:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007504 (V, A, ohm, ...), Measured Value = 0.562763 (C, atm, Hz, ...) 17:02:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002421 V 17:02:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002421 (V, A, ohm, ...), Measured Value = 0.181553 (C, atm, Hz, ...) 17:02:07 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003646 V 17:02:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003646 (V, A, ohm, ...), Measured Value = -0.000619 (C, atm, Hz, ...) 17:02:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.75 P3 = Coil, Value = 31.48 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 27.67 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 17:03:08 Magnet Current for MAIN, Imag = 308.1049 A Vtrans = 3.080981 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:03:09 MAIN (V) Voltage Measurement, V = 11.976077 V 17:03:09 Temperature Measurement, Probe Number = 0, T = 30.793000 C 17:03:10 Temperature Measurement, Probe Number = 1, T = 31.447000 C 17:03:10 Temperature Measurement, Probe Number = 2, T = 28.580000 C 17:03:11 Temperature Measurement, Probe Number = 3, T = 32.404000 C 17:03:12 Temperature Measurement, Probe Number = 4, T = 27.737000 C 17:03:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007502 V 17:03:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007502 (V, A, ohm, ...), Measured Value = 0.562665 (C, atm, Hz, ...) 17:03:13 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002586 V 17:03:13 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002586 (V, A, ohm, ...), Measured Value = 0.193958 (C, atm, Hz, ...) 17:03:14 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003877 V 17:03:14 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003877 (V, A, ohm, ...), Measured Value = -0.000658 (C, atm, Hz, ...) 17:03:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.79 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.40 P6 = Ambient, Value = 27.74 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:04:14 Magnet Current for MAIN, Imag = 308.1027 A Vtrans = 3.080959 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:04:15 MAIN (V) Voltage Measurement, V = 11.977570 V 17:04:16 Temperature Measurement, Probe Number = 0, T = 30.808000 C 17:04:16 Temperature Measurement, Probe Number = 1, T = 31.467000 C 17:04:17 Temperature Measurement, Probe Number = 2, T = 28.590000 C 17:04:18 Temperature Measurement, Probe Number = 3, T = 32.431000 C 17:04:18 Temperature Measurement, Probe Number = 4, T = 27.814000 C 17:04:19 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007529 V 17:04:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007529 (V, A, ohm, ...), Measured Value = 0.564705 (C, atm, Hz, ...) 17:04:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002609 V 17:04:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002609 (V, A, ohm, ...), Measured Value = 0.195698 (C, atm, Hz, ...) 17:04:20 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000408 V 17:04:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000408 (V, A, ohm, ...), Measured Value = -0.000069 (C, atm, Hz, ...) 17:04:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.81 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.43 P6 = Ambient, Value = 27.81 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:05:21 Magnet Current for MAIN, Imag = 308.0971 A Vtrans = 3.080903 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:05:22 MAIN (V) Voltage Measurement, V = 11.978880 V 17:05:22 Temperature Measurement, Probe Number = 0, T = 30.807000 C 17:05:23 Temperature Measurement, Probe Number = 1, T = 31.475000 C 17:05:23 Temperature Measurement, Probe Number = 2, T = 28.584000 C 17:05:24 Temperature Measurement, Probe Number = 3, T = 32.288000 C 17:05:25 Temperature Measurement, Probe Number = 4, T = 27.756000 C 17:05:25 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007575 V 17:05:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007575 (V, A, ohm, ...), Measured Value = 0.568095 (C, atm, Hz, ...) 17:05:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002581 V 17:05:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002581 (V, A, ohm, ...), Measured Value = 0.193568 (C, atm, Hz, ...) 17:05:27 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000722 V 17:05:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000722 (V, A, ohm, ...), Measured Value = -0.000123 (C, atm, Hz, ...) 17:05:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.81 P3 = Coil, Value = 31.48 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.29 P6 = Ambient, Value = 27.76 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:06:27 Magnet Current for MAIN, Imag = 308.0933 A Vtrans = 3.080865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:06:28 MAIN (V) Voltage Measurement, V = 11.978923 V 17:06:29 Temperature Measurement, Probe Number = 0, T = 30.810000 C 17:06:29 Temperature Measurement, Probe Number = 1, T = 31.461000 C 17:06:30 Temperature Measurement, Probe Number = 2, T = 28.585000 C 17:06:30 Temperature Measurement, Probe Number = 3, T = 32.282000 C 17:06:31 Temperature Measurement, Probe Number = 4, T = 27.684000 C 17:06:32 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007478 V 17:06:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007478 (V, A, ohm, ...), Measured Value = 0.560827 (C, atm, Hz, ...) 17:06:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002596 V 17:06:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002596 (V, A, ohm, ...), Measured Value = 0.194730 (C, atm, Hz, ...) 17:06:33 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004110 V 17:06:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004110 (V, A, ohm, ...), Measured Value = -0.000698 (C, atm, Hz, ...) 17:06:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.81 P3 = Coil, Value = 31.46 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.68 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:07:34 Magnet Current for MAIN, Imag = 308.0945 A Vtrans = 3.080877 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:07:34 MAIN (V) Voltage Measurement, V = 11.978598 V 17:07:35 Temperature Measurement, Probe Number = 0, T = 30.807000 C 17:07:36 Temperature Measurement, Probe Number = 1, T = 31.447000 C 17:07:36 Temperature Measurement, Probe Number = 2, T = 28.590000 C 17:07:37 Temperature Measurement, Probe Number = 3, T = 32.329000 C 17:07:38 Temperature Measurement, Probe Number = 4, T = 27.698000 C 17:07:38 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007438 V 17:07:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007438 (V, A, ohm, ...), Measured Value = 0.557828 (C, atm, Hz, ...) 17:07:39 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002574 V 17:07:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002574 (V, A, ohm, ...), Measured Value = 0.193087 (C, atm, Hz, ...) 17:07:39 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002477 V 17:07:39 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002477 (V, A, ohm, ...), Measured Value = -0.000421 (C, atm, Hz, ...) 17:07:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.81 P3 = Coil, Value = 31.45 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.33 P6 = Ambient, Value = 27.70 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:08:40 Magnet Current for MAIN, Imag = 308.0870 A Vtrans = 3.080802 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:08:41 MAIN (V) Voltage Measurement, V = 11.979238 V 17:08:42 Temperature Measurement, Probe Number = 0, T = 30.826000 C 17:08:42 Temperature Measurement, Probe Number = 1, T = 31.442000 C 17:08:43 Temperature Measurement, Probe Number = 2, T = 28.575000 C 17:08:44 Temperature Measurement, Probe Number = 3, T = 32.449000 C 17:08:44 Temperature Measurement, Probe Number = 4, T = 27.743000 C 17:08:45 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007427 V 17:08:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007427 (V, A, ohm, ...), Measured Value = 0.557048 (C, atm, Hz, ...) 17:08:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002630 V 17:08:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002630 (V, A, ohm, ...), Measured Value = 0.197250 (C, atm, Hz, ...) 17:08:46 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000540 V 17:08:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000540 (V, A, ohm, ...), Measured Value = 0.000092 (C, atm, Hz, ...) 17:08:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.83 P3 = Coil, Value = 31.44 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.45 P6 = Ambient, Value = 27.74 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 17:09:47 Magnet Current for MAIN, Imag = 308.0947 A Vtrans = 3.080879 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:09:47 MAIN (V) Voltage Measurement, V = 11.975483 V 17:09:48 Temperature Measurement, Probe Number = 0, T = 30.832000 C 17:09:49 Temperature Measurement, Probe Number = 1, T = 31.472000 C 17:09:49 Temperature Measurement, Probe Number = 2, T = 28.568000 C 17:09:50 Temperature Measurement, Probe Number = 3, T = 32.383000 C 17:09:51 Temperature Measurement, Probe Number = 4, T = 27.790000 C 17:09:51 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007470 V 17:09:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007470 (V, A, ohm, ...), Measured Value = 0.560250 (C, atm, Hz, ...) 17:09:52 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002580 V 17:09:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002580 (V, A, ohm, ...), Measured Value = 0.193470 (C, atm, Hz, ...) 17:09:52 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000058 V 17:09:52 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000058 (V, A, ohm, ...), Measured Value = -0.000010 (C, atm, Hz, ...) 17:09:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.83 P3 = Coil, Value = 31.47 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.38 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:10:53 Magnet Current for MAIN, Imag = 308.0956 A Vtrans = 3.080888 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:10:54 MAIN (V) Voltage Measurement, V = 11.977571 V 17:10:54 Temperature Measurement, Probe Number = 0, T = 30.824000 C 17:10:55 Temperature Measurement, Probe Number = 1, T = 31.493000 C 17:10:56 Temperature Measurement, Probe Number = 2, T = 28.576000 C 17:10:56 Temperature Measurement, Probe Number = 3, T = 32.345000 C 17:10:57 Temperature Measurement, Probe Number = 4, T = 27.792000 C 17:10:58 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007454 V 17:10:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007454 (V, A, ohm, ...), Measured Value = 0.559087 (C, atm, Hz, ...) 17:10:58 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002502 V 17:10:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002502 (V, A, ohm, ...), Measured Value = 0.187658 (C, atm, Hz, ...) 17:10:59 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001942 V 17:10:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001942 (V, A, ohm, ...), Measured Value = -0.000330 (C, atm, Hz, ...) 17:10:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.82 P3 = Coil, Value = 31.49 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.34 P6 = Ambient, Value = 27.79 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:12:00 Magnet Current for MAIN, Imag = 308.0971 A Vtrans = 3.080903 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:12:00 MAIN (V) Voltage Measurement, V = 11.979416 V 17:12:01 Temperature Measurement, Probe Number = 0, T = 30.818000 C 17:12:01 Temperature Measurement, Probe Number = 1, T = 31.499000 C 17:12:02 Temperature Measurement, Probe Number = 2, T = 28.574000 C 17:12:03 Temperature Measurement, Probe Number = 3, T = 32.276000 C 17:12:03 Temperature Measurement, Probe Number = 4, T = 27.769000 C 17:12:04 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007497 V 17:12:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007497 (V, A, ohm, ...), Measured Value = 0.562282 (C, atm, Hz, ...) 17:12:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002684 V 17:12:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002684 (V, A, ohm, ...), Measured Value = 0.201323 (C, atm, Hz, ...) 17:12:05 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000074 V 17:12:05 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000074 (V, A, ohm, ...), Measured Value = 0.000013 (C, atm, Hz, ...) 17:12:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.82 P3 = Coil, Value = 31.50 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 17:13:06 Magnet Current for MAIN, Imag = 308.0998 A Vtrans = 3.080930 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:13:07 MAIN (V) Voltage Measurement, V = 11.975602 V 17:13:07 Temperature Measurement, Probe Number = 0, T = 30.838000 C 17:13:08 Temperature Measurement, Probe Number = 1, T = 31.512000 C 17:13:09 Temperature Measurement, Probe Number = 2, T = 28.581000 C 17:13:09 Temperature Measurement, Probe Number = 3, T = 32.330000 C 17:13:10 Temperature Measurement, Probe Number = 4, T = 27.718000 C 17:13:10 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007537 V 17:13:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007537 (V, A, ohm, ...), Measured Value = 0.565282 (C, atm, Hz, ...) 17:13:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002625 V 17:13:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002625 (V, A, ohm, ...), Measured Value = 0.196860 (C, atm, Hz, ...) 17:13:12 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003263 V 17:13:12 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003263 (V, A, ohm, ...), Measured Value = -0.000554 (C, atm, Hz, ...) 17:13:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.84 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.33 P6 = Ambient, Value = 27.72 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:14:12 Magnet Current for MAIN, Imag = 308.0936 A Vtrans = 3.080868 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:14:13 MAIN (V) Voltage Measurement, V = 11.974015 V 17:14:14 Temperature Measurement, Probe Number = 0, T = 30.836000 C 17:14:14 Temperature Measurement, Probe Number = 1, T = 31.522000 C 17:14:15 Temperature Measurement, Probe Number = 2, T = 28.575000 C 17:14:15 Temperature Measurement, Probe Number = 3, T = 32.293000 C 17:14:16 Temperature Measurement, Probe Number = 4, T = 27.737000 C 17:14:17 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007606 V 17:14:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007606 (V, A, ohm, ...), Measured Value = 0.570420 (C, atm, Hz, ...) 17:14:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002558 V 17:14:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002558 (V, A, ohm, ...), Measured Value = 0.191828 (C, atm, Hz, ...) 17:14:18 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002714 V 17:14:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002714 (V, A, ohm, ...), Measured Value = -0.000461 (C, atm, Hz, ...) 17:14:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.84 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.29 P6 = Ambient, Value = 27.74 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:15:19 Magnet Current for MAIN, Imag = 308.0986 A Vtrans = 3.080918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:15:19 MAIN (V) Voltage Measurement, V = 11.975965 V 17:15:20 Temperature Measurement, Probe Number = 0, T = 30.841000 C 17:15:21 Temperature Measurement, Probe Number = 1, T = 31.519000 C 17:15:21 Temperature Measurement, Probe Number = 2, T = 28.581000 C 17:15:22 Temperature Measurement, Probe Number = 3, T = 32.283000 C 17:15:23 Temperature Measurement, Probe Number = 4, T = 27.706000 C 17:15:23 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007528 V 17:15:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007528 (V, A, ohm, ...), Measured Value = 0.564608 (C, atm, Hz, ...) 17:15:24 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002633 V 17:15:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002633 (V, A, ohm, ...), Measured Value = 0.197445 (C, atm, Hz, ...) 17:15:24 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000669 V 17:15:24 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000669 (V, A, ohm, ...), Measured Value = 0.000114 (C, atm, Hz, ...) 17:15:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.84 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 32.28 P6 = Ambient, Value = 27.71 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 17:16:25 Magnet Current for MAIN, Imag = 308.0989 A Vtrans = 3.080921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:16:26 MAIN (V) Voltage Measurement, V = 11.977754 V 17:16:27 Temperature Measurement, Probe Number = 0, T = 30.872000 C 17:16:27 Temperature Measurement, Probe Number = 1, T = 31.514000 C 17:16:28 Temperature Measurement, Probe Number = 2, T = 28.590000 C 17:16:28 Temperature Measurement, Probe Number = 3, T = 32.425000 C 17:16:29 Temperature Measurement, Probe Number = 4, T = 27.774000 C 17:16:30 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007516 V 17:16:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007516 (V, A, ohm, ...), Measured Value = 0.563737 (C, atm, Hz, ...) 17:16:30 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002652 V 17:16:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002652 (V, A, ohm, ...), Measured Value = 0.198900 (C, atm, Hz, ...) 17:16:31 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001680 V 17:16:31 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001680 (V, A, ohm, ...), Measured Value = -0.000285 (C, atm, Hz, ...) 17:16:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.87 P3 = Coil, Value = 31.51 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.42 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:17:32 Magnet Current for MAIN, Imag = 308.0991 A Vtrans = 3.080923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:17:32 MAIN (V) Voltage Measurement, V = 11.975002 V 17:17:33 Temperature Measurement, Probe Number = 0, T = 30.883000 C 17:17:33 Temperature Measurement, Probe Number = 1, T = 31.538000 C 17:17:34 Temperature Measurement, Probe Number = 2, T = 28.593000 C 17:17:35 Temperature Measurement, Probe Number = 3, T = 32.447000 C 17:17:35 Temperature Measurement, Probe Number = 4, T = 27.829000 C 17:17:36 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007630 V 17:17:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007630 (V, A, ohm, ...), Measured Value = 0.572258 (C, atm, Hz, ...) 17:17:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002744 V 17:17:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002744 (V, A, ohm, ...), Measured Value = 0.205777 (C, atm, Hz, ...) 17:17:37 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003851 V 17:17:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003851 (V, A, ohm, ...), Measured Value = -0.000654 (C, atm, Hz, ...) 17:17:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.88 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.45 P6 = Ambient, Value = 27.83 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 17:18:38 Magnet Current for MAIN, Imag = 308.0982 A Vtrans = 3.080914 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:18:39 MAIN (V) Voltage Measurement, V = 11.977635 V 17:18:39 Temperature Measurement, Probe Number = 0, T = 30.872000 C 17:18:40 Temperature Measurement, Probe Number = 1, T = 31.539000 C 17:18:40 Temperature Measurement, Probe Number = 2, T = 28.585000 C 17:18:41 Temperature Measurement, Probe Number = 3, T = 32.326000 C 17:18:42 Temperature Measurement, Probe Number = 4, T = 27.844000 C 17:18:42 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007554 V 17:18:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007554 (V, A, ohm, ...), Measured Value = 0.566543 (C, atm, Hz, ...) 17:18:43 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002599 V 17:18:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002599 (V, A, ohm, ...), Measured Value = 0.194925 (C, atm, Hz, ...) 17:18:43 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001842 V 17:18:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001842 (V, A, ohm, ...), Measured Value = -0.000313 (C, atm, Hz, ...) 17:18:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.87 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.33 P6 = Ambient, Value = 27.84 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:19:44 Magnet Current for MAIN, Imag = 308.0986 A Vtrans = 3.080918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:19:45 MAIN (V) Voltage Measurement, V = 11.977699 V 17:19:46 Temperature Measurement, Probe Number = 0, T = 30.883000 C 17:19:46 Temperature Measurement, Probe Number = 1, T = 31.522000 C 17:19:47 Temperature Measurement, Probe Number = 2, T = 28.587000 C 17:19:47 Temperature Measurement, Probe Number = 3, T = 32.356000 C 17:19:48 Temperature Measurement, Probe Number = 4, T = 27.777000 C 17:19:49 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007497 V 17:19:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007497 (V, A, ohm, ...), Measured Value = 0.562282 (C, atm, Hz, ...) 17:19:49 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002644 V 17:19:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002644 (V, A, ohm, ...), Measured Value = 0.198315 (C, atm, Hz, ...) 17:19:50 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001451 V 17:19:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001451 (V, A, ohm, ...), Measured Value = -0.000246 (C, atm, Hz, ...) 17:19:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.88 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.36 P6 = Ambient, Value = 27.78 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:20:51 Magnet Current for MAIN, Imag = 308.1016 A Vtrans = 3.080948 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:20:51 MAIN (V) Voltage Measurement, V = 11.977272 V 17:20:52 Temperature Measurement, Probe Number = 0, T = 30.888000 C 17:20:52 Temperature Measurement, Probe Number = 1, T = 31.527000 C 17:20:53 Temperature Measurement, Probe Number = 2, T = 28.597000 C 17:20:54 Temperature Measurement, Probe Number = 3, T = 32.368000 C 17:20:54 Temperature Measurement, Probe Number = 4, T = 27.769000 C 17:20:55 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007548 V 17:20:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007548 (V, A, ohm, ...), Measured Value = 0.566063 (C, atm, Hz, ...) 17:20:55 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002635 V 17:20:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002635 (V, A, ohm, ...), Measured Value = 0.197640 (C, atm, Hz, ...) 17:20:56 Sensor Voltage Measurement, Sensor Number = 2, V = -0.023260 V 17:20:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.023260 (V, A, ohm, ...), Measured Value = -0.003950 (C, atm, Hz, ...) 17:20:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.89 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 32.37 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:21:57 Magnet Current for MAIN, Imag = 308.0999 A Vtrans = 3.080931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:21:58 MAIN (V) Voltage Measurement, V = 11.975673 V 17:21:59 Temperature Measurement, Probe Number = 0, T = 30.886000 C 17:21:59 Temperature Measurement, Probe Number = 1, T = 31.520000 C 17:22:00 Temperature Measurement, Probe Number = 2, T = 28.596000 C 17:22:01 Temperature Measurement, Probe Number = 3, T = 32.362000 C 17:22:01 Temperature Measurement, Probe Number = 4, T = 27.774000 C 17:22:02 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007500 V 17:22:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007500 (V, A, ohm, ...), Measured Value = 0.562478 (C, atm, Hz, ...) 17:22:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002599 V 17:22:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002599 (V, A, ohm, ...), Measured Value = 0.194925 (C, atm, Hz, ...) 17:22:03 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001739 V 17:22:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001739 (V, A, ohm, ...), Measured Value = -0.000295 (C, atm, Hz, ...) 17:22:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.89 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 32.36 P6 = Ambient, Value = 27.77 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:23:04 Magnet Current for MAIN, Imag = 308.0964 A Vtrans = 3.080896 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:23:05 MAIN (V) Voltage Measurement, V = 11.973647 V 17:23:06 Temperature Measurement, Probe Number = 0, T = 30.905000 C 17:23:06 Temperature Measurement, Probe Number = 1, T = 31.527000 C 17:23:07 Temperature Measurement, Probe Number = 2, T = 28.596000 C 17:23:07 Temperature Measurement, Probe Number = 3, T = 32.473000 C 17:23:08 Temperature Measurement, Probe Number = 4, T = 27.824000 C 17:23:09 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007474 V 17:23:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007474 (V, A, ohm, ...), Measured Value = 0.560535 (C, atm, Hz, ...) 17:23:09 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002669 V 17:23:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002669 (V, A, ohm, ...), Measured Value = 0.200160 (C, atm, Hz, ...) 17:23:10 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001752 V 17:23:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001752 (V, A, ohm, ...), Measured Value = -0.000298 (C, atm, Hz, ...) 17:23:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.91 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 32.47 P6 = Ambient, Value = 27.82 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:24:11 Magnet Current for MAIN, Imag = 308.0950 A Vtrans = 3.080882 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:24:11 MAIN (V) Voltage Measurement, V = 11.972626 V 17:24:12 Temperature Measurement, Probe Number = 0, T = 30.898000 C 17:24:13 Temperature Measurement, Probe Number = 1, T = 31.535000 C 17:24:13 Temperature Measurement, Probe Number = 2, T = 28.586000 C 17:24:14 Temperature Measurement, Probe Number = 3, T = 32.383000 C 17:24:15 Temperature Measurement, Probe Number = 4, T = 27.824000 C 17:24:15 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007573 V 17:24:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007573 (V, A, ohm, ...), Measured Value = 0.567998 (C, atm, Hz, ...) 17:24:16 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002660 V 17:24:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002660 (V, A, ohm, ...), Measured Value = 0.199477 (C, atm, Hz, ...) 17:24:17 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003728 V 17:24:17 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003728 (V, A, ohm, ...), Measured Value = -0.000633 (C, atm, Hz, ...) 17:24:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.09 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.90 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.38 P6 = Ambient, Value = 27.82 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:25:17 Magnet Current for MAIN, Imag = 308.1013 A Vtrans = 3.080945 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:25:18 MAIN (V) Voltage Measurement, V = 11.974462 V 17:25:19 Temperature Measurement, Probe Number = 0, T = 30.928000 C 17:25:19 Temperature Measurement, Probe Number = 1, T = 31.522000 C 17:25:20 Temperature Measurement, Probe Number = 2, T = 28.588000 C 17:25:20 Temperature Measurement, Probe Number = 3, T = 32.542000 C 17:25:21 Temperature Measurement, Probe Number = 4, T = 27.847000 C 17:25:22 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007678 V 17:25:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007678 (V, A, ohm, ...), Measured Value = 0.575843 (C, atm, Hz, ...) 17:25:22 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002586 V 17:25:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002586 (V, A, ohm, ...), Measured Value = 0.193958 (C, atm, Hz, ...) 17:25:23 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000305 V 17:25:23 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000305 (V, A, ohm, ...), Measured Value = -0.000052 (C, atm, Hz, ...) 17:25:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.93 P3 = Coil, Value = 31.52 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.54 P6 = Ambient, Value = 27.85 P7 = Supply Pres(psi), Value = 0.58 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:26:24 Magnet Current for MAIN, Imag = 308.0971 A Vtrans = 3.080903 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:26:24 MAIN (V) Voltage Measurement, V = 11.974994 V 17:26:25 Temperature Measurement, Probe Number = 0, T = 30.936000 C 17:26:26 Temperature Measurement, Probe Number = 1, T = 31.540000 C 17:26:26 Temperature Measurement, Probe Number = 2, T = 28.596000 C 17:26:27 Temperature Measurement, Probe Number = 3, T = 32.535000 C 17:26:27 Temperature Measurement, Probe Number = 4, T = 27.898000 C 17:26:28 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007589 V 17:26:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007589 (V, A, ohm, ...), Measured Value = 0.569160 (C, atm, Hz, ...) 17:26:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002702 V 17:26:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002702 (V, A, ohm, ...), Measured Value = 0.202672 (C, atm, Hz, ...) 17:26:29 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002947 V 17:26:29 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002947 (V, A, ohm, ...), Measured Value = -0.000501 (C, atm, Hz, ...) 17:26:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.94 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 32.53 P6 = Ambient, Value = 27.90 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:27:30 Magnet Current for MAIN, Imag = 308.0954 A Vtrans = 3.080886 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:27:31 MAIN (V) Voltage Measurement, V = 11.975900 V 17:27:31 Temperature Measurement, Probe Number = 0, T = 30.922000 C 17:27:32 Temperature Measurement, Probe Number = 1, T = 31.551000 C 17:27:32 Temperature Measurement, Probe Number = 2, T = 28.594000 C 17:27:33 Temperature Measurement, Probe Number = 3, T = 32.424000 C 17:27:34 Temperature Measurement, Probe Number = 4, T = 27.883000 C 17:27:34 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007541 V 17:27:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007541 (V, A, ohm, ...), Measured Value = 0.565575 (C, atm, Hz, ...) 17:27:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002595 V 17:27:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002595 (V, A, ohm, ...), Measured Value = 0.194632 (C, atm, Hz, ...) 17:27:35 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003568 V 17:27:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003568 (V, A, ohm, ...), Measured Value = -0.000606 (C, atm, Hz, ...) 17:27:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.92 P3 = Coil, Value = 31.55 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.42 P6 = Ambient, Value = 27.88 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 17:28:36 Magnet Current for MAIN, Imag = 308.1022 A Vtrans = 3.080954 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:28:37 MAIN (V) Voltage Measurement, V = 11.976346 V 17:28:38 Temperature Measurement, Probe Number = 0, T = 30.927000 C 17:28:38 Temperature Measurement, Probe Number = 1, T = 31.541000 C 17:28:39 Temperature Measurement, Probe Number = 2, T = 28.605000 C 17:28:39 Temperature Measurement, Probe Number = 3, T = 32.423000 C 17:28:40 Temperature Measurement, Probe Number = 4, T = 27.834000 C 17:28:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007466 V 17:28:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007466 (V, A, ohm, ...), Measured Value = 0.559958 (C, atm, Hz, ...) 17:28:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002688 V 17:28:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002688 (V, A, ohm, ...), Measured Value = 0.201608 (C, atm, Hz, ...) 17:28:42 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000267 V 17:28:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000267 (V, A, ohm, ...), Measured Value = 0.000045 (C, atm, Hz, ...) 17:28:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.93 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.61 P5 = H2O_Out, Value = 32.42 P6 = Ambient, Value = 27.83 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = 0.00 17:29:43 Magnet Current for MAIN, Imag = 308.0972 A Vtrans = 3.080904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:29:43 MAIN (V) Voltage Measurement, V = 11.977276 V 17:29:44 Temperature Measurement, Probe Number = 0, T = 30.937000 C 17:29:44 Temperature Measurement, Probe Number = 1, T = 31.538000 C 17:29:45 Temperature Measurement, Probe Number = 2, T = 28.605000 C 17:29:46 Temperature Measurement, Probe Number = 3, T = 32.414000 C 17:29:46 Temperature Measurement, Probe Number = 4, T = 27.802000 C 17:29:47 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007484 V 17:29:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007484 (V, A, ohm, ...), Measured Value = 0.561315 (C, atm, Hz, ...) 17:29:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002741 V 17:29:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002741 (V, A, ohm, ...), Measured Value = 0.205582 (C, atm, Hz, ...) 17:29:48 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003643 V 17:29:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003643 (V, A, ohm, ...), Measured Value = -0.000619 (C, atm, Hz, ...) 17:29:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.94 P3 = Coil, Value = 31.54 P4 = H20_In, Value = 28.61 P5 = H2O_Out, Value = 32.41 P6 = Ambient, Value = 27.80 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 17:30:49 Magnet Current for MAIN, Imag = 308.0978 A Vtrans = 3.080910 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 17:30:49 MAIN (V) Voltage Measurement, V = 11.978830 V 17:30:50 Temperature Measurement, Probe Number = 0, T = 30.938000 C 17:30:51 Temperature Measurement, Probe Number = 1, T = 31.532000 C 17:30:51 Temperature Measurement, Probe Number = 2, T = 28.588000 C 17:30:52 Temperature Measurement, Probe Number = 3, T = 32.396000 C 17:30:52 Temperature Measurement, Probe Number = 4, T = 27.847000 C 17:30:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007631 V 17:30:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007631 (V, A, ohm, ...), Measured Value = 0.572355 (C, atm, Hz, ...) 17:30:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002685 V 17:30:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002685 (V, A, ohm, ...), Measured Value = 0.201412 (C, atm, Hz, ...) 17:30:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000254 V 17:30:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000254 (V, A, ohm, ...), Measured Value = -0.000043 (C, atm, Hz, ...) 17:30:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.10 P1 = MAIN (V), Value = 11.98 P2 = Yoke, Value = 30.94 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 32.40 P6 = Ambient, Value = 27.85 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 17:30:54 Magnet system MAIN current ramping to 0.0000 A... 17:32:31 Magnet system MAIN current ramping to 380.0000 A... 17:34:28 Magnet system MAIN current ramping to 0.0000 A... 17:36:24 Magnet system MAIN current ramping to 380.0000 A... 17:38:21 Magnet system MAIN current ramping to 0.0000 A... 17:40:18 Magnet system MAIN current ramping to 380.0000 A... 17:42:15 Magnet system MAIN current ramping to 0.0000 A... 17:44:11 Magnet system MAIN current ramping to 380.0000 A... 17:46:08 Magnet system MAIN current ramping to 0.0000 A... 17:48:05 Magnet system MAIN current ramping to 380.0000 A... 17:50:01 Magnet system MAIN current ramping to 0.0000 A... 17:51:58 Magnet system MAIN current ramping to 380.0000 A... 17:53:55 Magnet system MAIN current ramping to 0.0000 A... 17:55:52 Magnet system MAIN current ramping to 380.0000 A... 17:57:48 Magnet system MAIN current ramping to 0.0000 A... 17:59:45 Magnet system MAIN current ramping to 380.0000 A... 18:01:42 Magnet system MAIN current ramping to 0.0000 A... 18:03:38 Magnet system MAIN current ramping to 380.0000 A... 18:05:35 Magnet system MAIN current ramping to 0.0000 A... 18:07:32 Magnet system MAIN current ramping to 380.0000 A... 18:09:29 Magnet system MAIN current ramping to 0.0000 A... 18:11:25 Magnet system MAIN current ramping to 380.0000 A... 18:13:22 Magnet system MAIN current ramping to 0.0000 A... 18:15:19 Magnet system MAIN current ramping to 380.0000 A... 18:17:16 Magnet system MAIN current ramping to 0.0000 A... 18:19:12 Magnet system MAIN current ramping to 380.0000 A... 18:21:09 Magnet system MAIN current ramping to 0.0000 A... 18:23:06 Magnet system MAIN current ramping to 380.0000 A... 18:25:02 Magnet system MAIN current ramping to 0.0000 A... 18:26:59 Magnet system MAIN current ramping to 380.0000 A... 18:28:56 Magnet system MAIN current ramping to 0.0000 A... 18:30:55 Position moved: 0.000000 m 18:30:58 Magnet system MAIN current ramping to 0.0000 A... 18:31:09 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:31:10 MAIN (V) Voltage Measurement, V = 0.000025 V 18:31:10 Temperature Measurement, Probe Number = 0, T = 30.802000 C 18:31:11 Temperature Measurement, Probe Number = 1, T = 30.148000 C 18:31:12 Temperature Measurement, Probe Number = 2, T = 28.620000 C 18:31:12 Temperature Measurement, Probe Number = 3, T = 30.219000 C 18:31:13 Temperature Measurement, Probe Number = 4, T = 27.868000 C 18:31:13 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007693 V 18:31:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007693 (V, A, ohm, ...), Measured Value = 0.577005 (C, atm, Hz, ...) 18:31:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003008 V 18:31:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003008 (V, A, ohm, ...), Measured Value = 0.225637 (C, atm, Hz, ...) 18:31:15 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001992 V 18:31:15 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001992 (V, A, ohm, ...), Measured Value = -0.000338 (C, atm, Hz, ...) 18:31:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = MAIN (V), Value = 0.00 P2 = Yoke, Value = 30.80 P3 = Coil, Value = 30.15 P4 = H20_In, Value = 28.62 P5 = H2O_Out, Value = 30.22 P6 = Ambient, Value = 27.87 P7 = Supply Pres(psi), Value = 0.58 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 18:31:15 Magnetic Field Measurement Measuring the magnet strength... 18:31:15 Integrated Voltage Measurement... 18:31:16 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = -0.000066 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:31:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000030887 Vs 18:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = -0.000004108 Vs 18:31:33 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000037081 Vs 18:31:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = -0.000006394 Vs 18:31:50 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:31:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000038332 Vs 18:32:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = -0.000008165 Vs 18:32:07 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:32:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000037702 Vs 18:32:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = -0.000008085 Vs 18:32:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000014656 +- 0.000000755 Vs 18:32:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000014656 +- 0.000000755 Vs BL = -0.00018320 +- 0.00000944 Tm 18:32:27 Position moved: 0.000000 m 18:32:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00018 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00018 0.00001 -0.00018 0.00000 18:32:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00018 0.00001 SL = -0.0001832 +- 0.0000094 Tm^2/m^n 18:32:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001832 +- 0.0000094 Tm^2/m^n 18:32:30 Position moved: 0.000000 m 18:32:30 Magnet system MAIN current ramping to 14.0000 A... 18:32:45 Magnet Current for MAIN, Imag = 13.8999 A Vtrans = 0.138931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:32:45 MAIN (V) Voltage Measurement, V = 0.536717 V 18:32:46 Temperature Measurement, Probe Number = 0, T = 30.772000 C 18:32:46 Temperature Measurement, Probe Number = 1, T = 29.681000 C 18:32:47 Temperature Measurement, Probe Number = 2, T = 28.602000 C 18:32:48 Temperature Measurement, Probe Number = 3, T = 29.344000 C 18:32:48 Temperature Measurement, Probe Number = 4, T = 27.804000 C 18:32:49 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007607 V 18:32:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007607 (V, A, ohm, ...), Measured Value = 0.570518 (C, atm, Hz, ...) 18:32:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003054 V 18:32:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003054 (V, A, ohm, ...), Measured Value = 0.229027 (C, atm, Hz, ...) 18:32:50 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002122 V 18:32:50 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002122 (V, A, ohm, ...), Measured Value = -0.000360 (C, atm, Hz, ...) 18:32:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 13.90 P1 = MAIN (V), Value = 0.54 P2 = Yoke, Value = 30.77 P3 = Coil, Value = 29.68 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 29.34 P6 = Ambient, Value = 27.80 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 18:32:50 Magnetic Field Measurement Measuring the magnet strength... 18:32:50 Integrated Voltage Measurement... 18:32:51 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:33:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000415210 Vs 18:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000384947 Vs 18:33:09 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000416255 Vs 18:33:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000384933 Vs 18:33:26 Magnet Current for MAIN, Imag = 13.9004 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:33:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000413606 Vs 18:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000386360 Vs 18:33:42 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:33:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000412125 Vs 18:33:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000388392 Vs 18:33:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000400229 +- 0.000000233 Vs 18:33:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000400229 +- 0.000000233 Vs BL = -0.00500286 +- 0.00000292 Tm 18:34:02 Position moved: 0.000000 m 18:34:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00500 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00500 0.00000 -0.00500 0.00000 18:34:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00500 0.00000 SL = -0.0050029 +- 0.0000029 Tm^2/m^n 18:34:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0050029 +- 0.0000029 Tm^2/m^n Remeasure 18:34:02 Magnetic Field Measurement Measuring the magnet strength... 18:34:02 Integrated Voltage Measurement... 18:34:03 Magnet Current for MAIN, Imag = 13.9005 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:34:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000412733 Vs 18:34:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000386806 Vs 18:34:20 Magnet Current for MAIN, Imag = 13.9003 A Vtrans = 0.138935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:34:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000413006 Vs 18:34:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000384910 Vs 18:34:36 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:34:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000415587 Vs 18:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000379336 Vs 18:34:53 Magnet Current for MAIN, Imag = 13.9004 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:35:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000421923 Vs 18:35:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000376344 Vs 18:35:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000398831 +- 0.000000846 Vs 18:35:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000398831 +- 0.000000846 Vs BL = -0.00498538 +- 0.00001058 Tm 18:35:12 Position moved: 0.000000 m 18:35:12 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00499 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00499 0.00001 -0.00499 0.00000 18:35:12 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00499 0.00001 SL = -0.0049854 +- 0.0000106 Tm^2/m^n 18:35:12 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0049854 +- 0.0000106 Tm^2/m^n Remeasure 18:35:12 Magnetic Field Measurement Measuring the magnet strength... 18:35:12 Integrated Voltage Measurement... 18:35:13 Magnet Current for MAIN, Imag = 13.9006 A Vtrans = 0.138938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000424814 Vs 18:35:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000375295 Vs 18:35:30 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000424494 Vs 18:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000374176 Vs 18:35:47 Magnet Current for MAIN, Imag = 13.9002 A Vtrans = 0.138934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:35:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000423701 Vs 18:36:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000374453 Vs 18:36:03 Magnet Current for MAIN, Imag = 13.9004 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:36:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000422152 Vs 18:36:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000375648 Vs 18:36:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000399342 +- 0.000000440 Vs 18:36:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000399342 +- 0.000000440 Vs BL = -0.00499177 +- 0.00000550 Tm 18:36:23 Position moved: 0.000000 m 18:36:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00499 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00499 0.00001 -0.00499 0.00000 18:36:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00499 0.00001 SL = -0.0049918 +- 0.0000055 Tm^2/m^n 18:36:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0049918 +- 0.0000055 Tm^2/m^n 18:36:26 Position moved: 0.000000 m 18:36:26 Magnet system MAIN current ramping to 28.0000 A... 18:36:41 Magnet Current for MAIN, Imag = 27.8484 A Vtrans = 0.278416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:36:42 MAIN (V) Voltage Measurement, V = 1.076434 V 18:36:42 Temperature Measurement, Probe Number = 0, T = 30.694000 C 18:36:43 Temperature Measurement, Probe Number = 1, T = 29.190000 C 18:36:43 Temperature Measurement, Probe Number = 2, T = 28.565000 C 18:36:44 Temperature Measurement, Probe Number = 3, T = 28.620000 C 18:36:45 Temperature Measurement, Probe Number = 4, T = 27.735000 C 18:36:45 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007550 V 18:36:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007550 (V, A, ohm, ...), Measured Value = 0.566250 (C, atm, Hz, ...) 18:36:46 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002989 V 18:36:46 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002989 (V, A, ohm, ...), Measured Value = 0.224182 (C, atm, Hz, ...) 18:36:47 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001703 V 18:36:47 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001703 (V, A, ohm, ...), Measured Value = -0.000289 (C, atm, Hz, ...) 18:36:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 27.85 P1 = MAIN (V), Value = 1.08 P2 = Yoke, Value = 30.69 P3 = Coil, Value = 29.19 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 28.62 P6 = Ambient, Value = 27.73 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 18:36:47 Magnetic Field Measurement Measuring the magnet strength... 18:36:47 Integrated Voltage Measurement... 18:36:47 Magnet Current for MAIN, Imag = 27.8482 A Vtrans = 0.278414 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000818317 Vs 18:37:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000768154 Vs 18:37:05 Magnet Current for MAIN, Imag = 27.8481 A Vtrans = 0.278413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:37:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000818639 Vs 18:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000766226 Vs 18:37:21 Magnet Current for MAIN, Imag = 27.8482 A Vtrans = 0.278414 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:37:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000820642 Vs 18:37:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000769151 Vs 18:37:38 Magnet Current for MAIN, Imag = 27.8483 A Vtrans = 0.278415 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:37:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000814268 Vs 18:37:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000770323 Vs 18:37:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000793215 +- 0.000001035 Vs 18:37:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000793215 +- 0.000001035 Vs BL = -0.00991519 +- 0.00001294 Tm 18:37:57 Position moved: 0.000000 m 18:37:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00992 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00992 0.00001 -0.00992 0.00000 18:37:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00992 0.00001 SL = -0.0099152 +- 0.0000129 Tm^2/m^n 18:37:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0099152 +- 0.0000129 Tm^2/m^n Remeasure 18:37:57 Magnetic Field Measurement Measuring the magnet strength... 18:37:57 Integrated Voltage Measurement... 18:37:58 Magnet Current for MAIN, Imag = 27.8484 A Vtrans = 0.278416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:38:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000813429 Vs 18:38:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000775385 Vs 18:38:15 Magnet Current for MAIN, Imag = 27.8483 A Vtrans = 0.278415 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:38:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000808086 Vs 18:38:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000776246 Vs 18:38:32 Magnet Current for MAIN, Imag = 27.8482 A Vtrans = 0.278413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000811257 Vs 18:38:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000774201 Vs 18:38:48 Magnet Current for MAIN, Imag = 27.8483 A Vtrans = 0.278415 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:38:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812568 Vs 18:39:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000773178 Vs 18:39:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000793044 +- 0.000000830 Vs 18:39:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000793044 +- 0.000000830 Vs BL = -0.00991305 +- 0.00001037 Tm 18:39:08 Position moved: 0.000000 m 18:39:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00991 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00991 0.00001 -0.00991 0.00000 18:39:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00991 0.00001 SL = -0.0099130 +- 0.0000104 Tm^2/m^n 18:39:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0099130 +- 0.0000104 Tm^2/m^n Remeasure 18:39:08 Magnetic Field Measurement Measuring the magnet strength... 18:39:08 Integrated Voltage Measurement... 18:39:08 Magnet Current for MAIN, Imag = 27.8484 A Vtrans = 0.278416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000816427 Vs 18:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000771662 Vs 18:39:26 Magnet Current for MAIN, Imag = 27.8481 A Vtrans = 0.278413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:39:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000811789 Vs 18:39:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000775325 Vs 18:39:42 Magnet Current for MAIN, Imag = 27.8481 A Vtrans = 0.278413 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:39:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000807240 Vs 18:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000777493 Vs 18:39:58 Magnet Current for MAIN, Imag = 27.8484 A Vtrans = 0.278416 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000806452 Vs 18:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000775345 Vs 18:40:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000792717 +- 0.000001214 Vs 18:40:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000792717 +- 0.000001214 Vs BL = -0.00990896 +- 0.00001518 Tm 18:40:18 Position moved: 0.000000 m 18:40:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00991 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00991 0.00002 -0.00991 0.00000 18:40:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00991 0.00002 SL = -0.0099090 +- 0.0000152 Tm^2/m^n 18:40:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0099090 +- 0.0000152 Tm^2/m^n 18:40:21 Position moved: 0.000000 m 18:40:21 Magnet system MAIN current ramping to 42.0000 A... 18:40:35 Magnet Current for MAIN, Imag = 41.9539 A Vtrans = 0.419471 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:40:36 MAIN (V) Voltage Measurement, V = 1.622878 V 18:40:37 Temperature Measurement, Probe Number = 0, T = 30.630000 C 18:40:37 Temperature Measurement, Probe Number = 1, T = 29.083000 C 18:40:38 Temperature Measurement, Probe Number = 2, T = 28.550000 C 18:40:39 Temperature Measurement, Probe Number = 3, T = 28.513000 C 18:40:39 Temperature Measurement, Probe Number = 4, T = 27.805000 C 18:40:40 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007549 V 18:40:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007549 (V, A, ohm, ...), Measured Value = 0.566153 (C, atm, Hz, ...) 18:40:40 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002697 V 18:40:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002697 (V, A, ohm, ...), Measured Value = 0.202290 (C, atm, Hz, ...) 18:40:41 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000208 V 18:40:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000208 (V, A, ohm, ...), Measured Value = -0.000035 (C, atm, Hz, ...) 18:40:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 41.95 P1 = MAIN (V), Value = 1.62 P2 = Yoke, Value = 30.63 P3 = Coil, Value = 29.08 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 28.51 P6 = Ambient, Value = 27.80 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 18:40:41 Magnetic Field Measurement Measuring the magnet strength... 18:40:41 Integrated Voltage Measurement... 18:40:42 Magnet Current for MAIN, Imag = 41.9540 A Vtrans = 0.419472 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001206783 Vs 18:40:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001178943 Vs 18:40:59 Magnet Current for MAIN, Imag = 41.9537 A Vtrans = 0.419469 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001203465 Vs 18:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001180848 Vs 18:41:15 Magnet Current for MAIN, Imag = 41.9537 A Vtrans = 0.419469 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:41:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001204669 Vs 18:41:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001182687 Vs 18:41:32 Magnet Current for MAIN, Imag = 41.9539 A Vtrans = 0.419471 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:41:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001202030 Vs 18:41:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001182974 Vs 18:41:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001192800 +- 0.000000565 Vs 18:41:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001192800 +- 0.000000565 Vs BL = -0.01491000 +- 0.00000707 Tm 18:41:51 Position moved: 0.000000 m 18:41:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01491 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01491 0.00001 -0.01491 0.00000 18:41:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01491 0.00001 SL = -0.0149100 +- 0.0000071 Tm^2/m^n 18:41:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0149100 +- 0.0000071 Tm^2/m^n Remeasure 18:41:51 Magnetic Field Measurement Measuring the magnet strength... 18:41:51 Integrated Voltage Measurement... 18:41:52 Magnet Current for MAIN, Imag = 41.9538 A Vtrans = 0.419470 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:42:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001200145 Vs 18:42:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001184865 Vs 18:42:09 Magnet Current for MAIN, Imag = 41.9537 A Vtrans = 0.419469 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:42:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001200721 Vs 18:42:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001184813 Vs 18:42:26 Magnet Current for MAIN, Imag = 41.9537 A Vtrans = 0.419469 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:42:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001202080 Vs 18:42:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001183835 Vs 18:42:42 Magnet Current for MAIN, Imag = 41.9536 A Vtrans = 0.419468 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:42:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001200838 Vs 18:42:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001184741 Vs 18:42:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001192755 +- 0.000000162 Vs 18:42:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001192755 +- 0.000000162 Vs BL = -0.01490943 +- 0.00000202 Tm 18:43:02 Position moved: 0.000000 m 18:43:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01491 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01491 0.00000 -0.01491 0.00000 18:43:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01491 0.00000 SL = -0.0149094 +- 0.0000020 Tm^2/m^n 18:43:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0149094 +- 0.0000020 Tm^2/m^n 18:43:04 Position moved: 0.000000 m 18:43:04 Magnet system MAIN current ramping to 56.0000 A... 18:43:19 Magnet Current for MAIN, Imag = 55.9009 A Vtrans = 0.558941 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:43:20 MAIN (V) Voltage Measurement, V = 2.164246 V 18:43:21 Temperature Measurement, Probe Number = 0, T = 30.584000 C 18:43:21 Temperature Measurement, Probe Number = 1, T = 29.092000 C 18:43:22 Temperature Measurement, Probe Number = 2, T = 28.552000 C 18:43:22 Temperature Measurement, Probe Number = 3, T = 28.559000 C 18:43:23 Temperature Measurement, Probe Number = 4, T = 27.834000 C 18:43:24 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007568 V 18:43:24 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007568 (V, A, ohm, ...), Measured Value = 0.567608 (C, atm, Hz, ...) 18:43:24 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002802 V 18:43:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002802 (V, A, ohm, ...), Measured Value = 0.210135 (C, atm, Hz, ...) 18:43:25 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000084 V 18:43:25 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000084 (V, A, ohm, ...), Measured Value = -0.000014 (C, atm, Hz, ...) 18:43:25 Magnet Test Parameter Measurements P0 = MAIN, Value = 55.90 P1 = MAIN (V), Value = 2.16 P2 = Yoke, Value = 30.58 P3 = Coil, Value = 29.09 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 28.56 P6 = Ambient, Value = 27.83 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 18:43:25 Magnetic Field Measurement Measuring the magnet strength... 18:43:25 Integrated Voltage Measurement... 18:43:26 Magnet Current for MAIN, Imag = 55.9005 A Vtrans = 0.558937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:43:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001599276 Vs 18:43:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001579607 Vs 18:43:44 Magnet Current for MAIN, Imag = 55.9006 A Vtrans = 0.558938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:43:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001596267 Vs 18:43:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001579893 Vs 18:44:00 Magnet Current for MAIN, Imag = 55.9008 A Vtrans = 0.558939 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:44:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001594603 Vs 18:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001582004 Vs 18:44:17 Magnet Current for MAIN, Imag = 55.9002 A Vtrans = 0.558934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001594504 Vs 18:44:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001580840 Vs 18:44:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001588374 +- 0.000000657 Vs 18:44:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001588374 +- 0.000000657 Vs BL = -0.01985468 +- 0.00000821 Tm 18:44:37 Position moved: 0.000000 m 18:44:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01985 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01985 0.00001 -0.01985 0.00000 18:44:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01985 0.00001 SL = -0.0198547 +- 0.0000082 Tm^2/m^n 18:44:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0198547 +- 0.0000082 Tm^2/m^n Remeasure 18:44:37 Magnetic Field Measurement Measuring the magnet strength... 18:44:37 Integrated Voltage Measurement... 18:44:37 Magnet Current for MAIN, Imag = 55.9004 A Vtrans = 0.558935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:44:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001593516 Vs 18:44:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001581860 Vs 18:44:55 Magnet Current for MAIN, Imag = 55.9005 A Vtrans = 0.558937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:45:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001593982 Vs 18:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001580899 Vs 18:45:12 Magnet Current for MAIN, Imag = 55.9004 A Vtrans = 0.558936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001595616 Vs 18:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001582800 Vs 18:45:28 Magnet Current for MAIN, Imag = 55.9006 A Vtrans = 0.558938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:45:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001595727 Vs 18:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001583327 Vs 18:45:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001588466 +- 0.000000913 Vs 18:45:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001588466 +- 0.000000913 Vs BL = -0.01985582 +- 0.00001141 Tm 18:45:48 Position moved: 0.000000 m 18:45:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01986 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01986 0.00001 -0.01986 0.00000 18:45:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01986 0.00001 SL = -0.0198558 +- 0.0000114 Tm^2/m^n 18:45:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0198558 +- 0.0000114 Tm^2/m^n Remeasure 18:45:48 Magnetic Field Measurement Measuring the magnet strength... 18:45:48 Integrated Voltage Measurement... 18:45:49 Magnet Current for MAIN, Imag = 55.9006 A Vtrans = 0.558938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001592828 Vs 18:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001583792 Vs 18:46:06 Magnet Current for MAIN, Imag = 55.9006 A Vtrans = 0.558938 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001593429 Vs 18:46:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001584841 Vs 18:46:22 Magnet Current for MAIN, Imag = 55.9005 A Vtrans = 0.558937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001593659 Vs 18:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001585422 Vs 18:46:39 Magnet Current for MAIN, Imag = 55.9003 A Vtrans = 0.558935 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:46:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001591998 Vs 18:46:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001586190 Vs 18:46:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001589020 +- 0.000000445 Vs 18:46:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001589020 +- 0.000000445 Vs BL = -0.01986275 +- 0.00000557 Tm 18:46:58 Position moved: 0.000000 m 18:46:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01986 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01986 0.00001 -0.01986 0.00000 18:46:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01986 0.00001 SL = -0.0198627 +- 0.0000056 Tm^2/m^n 18:46:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0198627 +- 0.0000056 Tm^2/m^n 18:47:01 Position moved: 0.000000 m 18:47:01 Magnet system MAIN current ramping to 70.0000 A... 18:47:16 Magnet Current for MAIN, Imag = 69.8568 A Vtrans = 0.698500 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:47:16 MAIN (V) Voltage Measurement, V = 2.706996 V 18:47:17 Temperature Measurement, Probe Number = 0, T = 30.537000 C 18:47:18 Temperature Measurement, Probe Number = 1, T = 29.120000 C 18:47:18 Temperature Measurement, Probe Number = 2, T = 28.554000 C 18:47:19 Temperature Measurement, Probe Number = 3, T = 28.661000 C 18:47:19 Temperature Measurement, Probe Number = 4, T = 27.857000 C 18:47:20 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007576 V 18:47:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007576 (V, A, ohm, ...), Measured Value = 0.568192 (C, atm, Hz, ...) 18:47:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002781 V 18:47:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002781 (V, A, ohm, ...), Measured Value = 0.208582 (C, atm, Hz, ...) 18:47:21 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000300 V 18:47:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000300 (V, A, ohm, ...), Measured Value = -0.000051 (C, atm, Hz, ...) 18:47:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 69.86 P1 = MAIN (V), Value = 2.71 P2 = Yoke, Value = 30.54 P3 = Coil, Value = 29.12 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 28.66 P6 = Ambient, Value = 27.86 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 18:47:21 Magnetic Field Measurement Measuring the magnet strength... 18:47:21 Integrated Voltage Measurement... 18:47:22 Magnet Current for MAIN, Imag = 69.8566 A Vtrans = 0.698498 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:47:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001990193 Vs 18:47:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001982057 Vs 18:47:40 Magnet Current for MAIN, Imag = 69.8568 A Vtrans = 0.698500 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:47:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001988047 Vs 18:47:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001981050 Vs 18:47:56 Magnet Current for MAIN, Imag = 69.8565 A Vtrans = 0.698497 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:48:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001986885 Vs 18:48:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001983293 Vs 18:48:12 Magnet Current for MAIN, Imag = 69.8565 A Vtrans = 0.698497 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:48:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001987872 Vs 18:48:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001982469 Vs 18:48:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001985233 +- 0.000000568 Vs 18:48:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001985233 +- 0.000000568 Vs BL = -0.02481542 +- 0.00000710 Tm 18:48:32 Position moved: 0.000000 m 18:48:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02482 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02482 0.00001 -0.02482 0.00000 18:48:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02482 0.00001 SL = -0.0248154 +- 0.0000071 Tm^2/m^n 18:48:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0248154 +- 0.0000071 Tm^2/m^n 18:48:35 Position moved: 0.000000 m 18:48:35 Magnet system MAIN current ramping to 84.0000 A... 18:48:50 Magnet Current for MAIN, Imag = 83.9616 A Vtrans = 0.839548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:48:51 MAIN (V) Voltage Measurement, V = 3.258526 V 18:48:51 Temperature Measurement, Probe Number = 0, T = 30.508000 C 18:48:52 Temperature Measurement, Probe Number = 1, T = 29.144000 C 18:48:53 Temperature Measurement, Probe Number = 2, T = 28.553000 C 18:48:53 Temperature Measurement, Probe Number = 3, T = 28.715000 C 18:48:54 Temperature Measurement, Probe Number = 4, T = 27.902000 C 18:48:54 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007518 V 18:48:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007518 (V, A, ohm, ...), Measured Value = 0.563827 (C, atm, Hz, ...) 18:48:55 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002940 V 18:48:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002940 (V, A, ohm, ...), Measured Value = 0.220500 (C, atm, Hz, ...) 18:48:56 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001055 V 18:48:56 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001055 (V, A, ohm, ...), Measured Value = -0.000179 (C, atm, Hz, ...) 18:48:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 83.96 P1 = MAIN (V), Value = 3.26 P2 = Yoke, Value = 30.51 P3 = Coil, Value = 29.14 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 28.71 P6 = Ambient, Value = 27.90 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 18:48:56 Magnetic Field Measurement Measuring the magnet strength... 18:48:56 Integrated Voltage Measurement... 18:48:57 Magnet Current for MAIN, Imag = 83.9612 A Vtrans = 0.839543 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:49:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002389894 Vs 18:49:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002384182 Vs 18:49:14 Magnet Current for MAIN, Imag = 83.9609 A Vtrans = 0.839541 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:49:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002386889 Vs 18:49:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002383627 Vs 18:49:31 Magnet Current for MAIN, Imag = 83.9614 A Vtrans = 0.839546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:49:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002389150 Vs 18:49:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002384087 Vs 18:49:48 Magnet Current for MAIN, Imag = 83.9613 A Vtrans = 0.839545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:49:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002387449 Vs 18:50:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002383115 Vs 18:50:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002386049 +- 0.000000793 Vs 18:50:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002386049 +- 0.000000793 Vs BL = -0.02982561 +- 0.00000992 Tm 18:50:07 Position moved: 0.000000 m 18:50:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02983 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02983 0.00001 -0.02983 0.00000 18:50:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02983 0.00001 SL = -0.0298256 +- 0.0000099 Tm^2/m^n 18:50:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0298256 +- 0.0000099 Tm^2/m^n Remeasure 18:50:07 Magnetic Field Measurement Measuring the magnet strength... 18:50:08 Integrated Voltage Measurement... 18:50:08 Magnet Current for MAIN, Imag = 83.9614 A Vtrans = 0.839546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:50:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002388835 Vs 18:50:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002383410 Vs 18:50:26 Magnet Current for MAIN, Imag = 83.9618 A Vtrans = 0.839550 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:50:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002387298 Vs 18:50:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002384817 Vs 18:50:42 Magnet Current for MAIN, Imag = 83.9612 A Vtrans = 0.839544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:50:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002387783 Vs 18:50:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002384696 Vs 18:50:59 Magnet Current for MAIN, Imag = 83.9612 A Vtrans = 0.839544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:51:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002387744 Vs 18:51:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002383135 Vs 18:51:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002385965 +- 0.000000310 Vs 18:51:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002385965 +- 0.000000310 Vs BL = -0.02982456 +- 0.00000388 Tm 18:51:18 Position moved: 0.000000 m 18:51:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02982 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02982 0.00000 -0.02982 0.00000 18:51:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02982 0.00000 SL = -0.0298246 +- 0.0000039 Tm^2/m^n 18:51:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0298246 +- 0.0000039 Tm^2/m^n 18:51:21 Position moved: 0.000000 m 18:51:21 Magnet system MAIN current ramping to 98.0000 A... 18:51:36 Magnet Current for MAIN, Imag = 97.9063 A Vtrans = 0.978995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:51:37 MAIN (V) Voltage Measurement, V = 3.805779 V 18:51:38 Temperature Measurement, Probe Number = 0, T = 30.471000 C 18:51:38 Temperature Measurement, Probe Number = 1, T = 29.213000 C 18:51:39 Temperature Measurement, Probe Number = 2, T = 28.563000 C 18:51:39 Temperature Measurement, Probe Number = 3, T = 28.807000 C 18:51:40 Temperature Measurement, Probe Number = 4, T = 27.976000 C 18:51:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007470 V 18:51:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007470 (V, A, ohm, ...), Measured Value = 0.560250 (C, atm, Hz, ...) 18:51:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002874 V 18:51:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002874 (V, A, ohm, ...), Measured Value = 0.215558 (C, atm, Hz, ...) 18:51:42 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003817 V 18:51:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003817 (V, A, ohm, ...), Measured Value = -0.000648 (C, atm, Hz, ...) 18:51:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 97.91 P1 = MAIN (V), Value = 3.81 P2 = Yoke, Value = 30.47 P3 = Coil, Value = 29.21 P4 = H20_In, Value = 28.56 P5 = H2O_Out, Value = 28.81 P6 = Ambient, Value = 27.98 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 18:51:42 Magnetic Field Measurement Measuring the magnet strength... 18:51:42 Integrated Voltage Measurement... 18:51:43 Magnet Current for MAIN, Imag = 97.9063 A Vtrans = 0.978995 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:51:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002782945 Vs 18:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002779658 Vs 18:52:00 Magnet Current for MAIN, Imag = 97.9058 A Vtrans = 0.978990 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:52:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002781676 Vs 18:52:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002781497 Vs 18:52:17 Magnet Current for MAIN, Imag = 97.9061 A Vtrans = 0.978993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002784400 Vs 18:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002780502 Vs 18:52:33 Magnet Current for MAIN, Imag = 97.9064 A Vtrans = 0.978996 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:52:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002784452 Vs 18:52:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002780468 Vs 18:52:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002781950 +- 0.000000516 Vs 18:52:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002781950 +- 0.000000516 Vs BL = -0.03477437 +- 0.00000645 Tm 18:52:52 Position moved: 0.000000 m 18:52:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03477 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03477 0.00001 -0.03477 0.00000 18:52:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03477 0.00001 SL = -0.0347744 +- 0.0000064 Tm^2/m^n 18:52:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0347744 +- 0.0000064 Tm^2/m^n 18:52:55 Position moved: 0.000000 m 18:52:55 Magnet system MAIN current ramping to 112.0000 A... 18:53:10 Magnet Current for MAIN, Imag = 112.0111 A Vtrans = 1.120043 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:53:10 MAIN (V) Voltage Measurement, V = 4.360269 V 18:53:11 Temperature Measurement, Probe Number = 0, T = 30.443000 C 18:53:12 Temperature Measurement, Probe Number = 1, T = 29.257000 C 18:53:12 Temperature Measurement, Probe Number = 2, T = 28.565000 C 18:53:13 Temperature Measurement, Probe Number = 3, T = 28.869000 C 18:53:14 Temperature Measurement, Probe Number = 4, T = 27.977000 C 18:53:14 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007507 V 18:53:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007507 (V, A, ohm, ...), Measured Value = 0.563055 (C, atm, Hz, ...) 18:53:15 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002961 V 18:53:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002961 (V, A, ohm, ...), Measured Value = 0.222053 (C, atm, Hz, ...) 18:53:16 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003386 V 18:53:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003386 (V, A, ohm, ...), Measured Value = -0.000575 (C, atm, Hz, ...) 18:53:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 112.01 P1 = MAIN (V), Value = 4.36 P2 = Yoke, Value = 30.44 P3 = Coil, Value = 29.26 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 28.87 P6 = Ambient, Value = 27.98 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 18:53:16 Magnetic Field Measurement Measuring the magnet strength... 18:53:16 Integrated Voltage Measurement... 18:53:16 Magnet Current for MAIN, Imag = 112.0119 A Vtrans = 1.120051 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:53:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003183000 Vs 18:53:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003178934 Vs 18:53:34 Magnet Current for MAIN, Imag = 112.0115 A Vtrans = 1.120047 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:53:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003185265 Vs 18:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003179535 Vs 18:53:50 Magnet Current for MAIN, Imag = 112.0123 A Vtrans = 1.120055 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003186504 Vs 18:54:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003177369 Vs 18:54:06 Magnet Current for MAIN, Imag = 112.0121 A Vtrans = 1.120053 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:54:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003186452 Vs 18:54:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003176716 Vs 18:54:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003181722 +- 0.000000523 Vs 18:54:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003181722 +- 0.000000523 Vs BL = -0.03977152 +- 0.00000654 Tm 18:54:25 Position moved: 0.000000 m 18:54:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03977 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03977 0.00001 -0.03977 0.00000 18:54:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03977 0.00001 SL = -0.0397715 +- 0.0000065 Tm^2/m^n 18:54:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0397715 +- 0.0000065 Tm^2/m^n 18:54:28 Position moved: 0.000000 m 18:54:28 Magnet system MAIN current ramping to 126.0000 A... 18:54:43 Magnet Current for MAIN, Imag = 125.9675 A Vtrans = 1.259607 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:54:44 MAIN (V) Voltage Measurement, V = 4.909832 V 18:54:45 Temperature Measurement, Probe Number = 0, T = 30.409000 C 18:54:45 Temperature Measurement, Probe Number = 1, T = 29.323000 C 18:54:46 Temperature Measurement, Probe Number = 2, T = 28.568000 C 18:54:46 Temperature Measurement, Probe Number = 3, T = 28.957000 C 18:54:47 Temperature Measurement, Probe Number = 4, T = 27.972000 C 18:54:48 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007633 V 18:54:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007633 (V, A, ohm, ...), Measured Value = 0.572453 (C, atm, Hz, ...) 18:54:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003040 V 18:54:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003040 (V, A, ohm, ...), Measured Value = 0.227963 (C, atm, Hz, ...) 18:54:49 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003242 V 18:54:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003242 (V, A, ohm, ...), Measured Value = -0.000551 (C, atm, Hz, ...) 18:54:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.97 P1 = MAIN (V), Value = 4.91 P2 = Yoke, Value = 30.41 P3 = Coil, Value = 29.32 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 28.96 P6 = Ambient, Value = 27.97 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 18:54:49 Magnetic Field Measurement Measuring the magnet strength... 18:54:49 Integrated Voltage Measurement... 18:54:50 Magnet Current for MAIN, Imag = 125.9676 A Vtrans = 1.259608 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:54:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003581622 Vs 18:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003571235 Vs 18:55:07 Magnet Current for MAIN, Imag = 125.9689 A Vtrans = 1.259621 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:55:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003582779 Vs 18:55:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003572507 Vs 18:55:23 Magnet Current for MAIN, Imag = 125.9688 A Vtrans = 1.259620 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:55:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003579637 Vs 18:55:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003572358 Vs 18:55:40 Magnet Current for MAIN, Imag = 125.9674 A Vtrans = 1.259605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:55:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003577767 Vs 18:55:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003571769 Vs 18:55:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003576209 +- 0.000001028 Vs 18:55:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003576209 +- 0.000001028 Vs BL = -0.04470261 +- 0.00001285 Tm 18:55:59 Position moved: 0.000000 m 18:55:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04470 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04470 0.00001 -0.04470 0.00000 18:55:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04470 0.00001 SL = -0.0447026 +- 0.0000128 Tm^2/m^n 18:55:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0447026 +- 0.0000128 Tm^2/m^n 18:56:02 Position moved: 0.000000 m 18:56:02 Magnet system MAIN current ramping to 140.0000 A... 18:56:17 Magnet Current for MAIN, Imag = 139.9174 A Vtrans = 1.399105 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:56:17 MAIN (V) Voltage Measurement, V = 5.451366 V 18:56:18 Temperature Measurement, Probe Number = 0, T = 30.383000 C 18:56:18 Temperature Measurement, Probe Number = 1, T = 29.394000 C 18:56:19 Temperature Measurement, Probe Number = 2, T = 28.574000 C 18:56:20 Temperature Measurement, Probe Number = 3, T = 29.077000 C 18:56:20 Temperature Measurement, Probe Number = 4, T = 28.004000 C 18:56:21 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007544 V 18:56:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007544 (V, A, ohm, ...), Measured Value = 0.565770 (C, atm, Hz, ...) 18:56:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002985 V 18:56:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002985 (V, A, ohm, ...), Measured Value = 0.223890 (C, atm, Hz, ...) 18:56:22 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002407 V 18:56:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002407 (V, A, ohm, ...), Measured Value = -0.000409 (C, atm, Hz, ...) 18:56:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.92 P1 = MAIN (V), Value = 5.45 P2 = Yoke, Value = 30.38 P3 = Coil, Value = 29.39 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 29.08 P6 = Ambient, Value = 28.00 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 18:56:22 Magnetic Field Measurement Measuring the magnet strength... 18:56:22 Integrated Voltage Measurement... 18:56:23 Magnet Current for MAIN, Imag = 139.9179 A Vtrans = 1.399111 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:56:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003975578 Vs 18:56:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003963504 Vs 18:56:40 Magnet Current for MAIN, Imag = 139.9154 A Vtrans = 1.399086 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:56:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003973260 Vs 18:56:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003963836 Vs 18:56:57 Magnet Current for MAIN, Imag = 139.9165 A Vtrans = 1.399096 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:57:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003974673 Vs 18:57:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003965336 Vs 18:57:13 Magnet Current for MAIN, Imag = 139.9184 A Vtrans = 1.399116 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:57:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003973872 Vs 18:57:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003964559 Vs 18:57:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003969327 +- 0.000000530 Vs 18:57:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003969327 +- 0.000000530 Vs BL = -0.04961659 +- 0.00000662 Tm 18:57:32 Position moved: 0.000000 m 18:57:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04962 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04962 0.00001 -0.04962 0.00000 18:57:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04962 0.00001 SL = -0.0496166 +- 0.0000066 Tm^2/m^n 18:57:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0496166 +- 0.0000066 Tm^2/m^n 18:57:35 Position moved: 0.000000 m 18:57:35 Magnet system MAIN current ramping to 154.0000 A... 18:57:50 Magnet Current for MAIN, Imag = 154.0397 A Vtrans = 1.540328 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:57:50 MAIN (V) Voltage Measurement, V = 5.987466 V 18:57:51 Temperature Measurement, Probe Number = 0, T = 30.356000 C 18:57:52 Temperature Measurement, Probe Number = 1, T = 29.482000 C 18:57:52 Temperature Measurement, Probe Number = 2, T = 28.580000 C 18:57:53 Temperature Measurement, Probe Number = 3, T = 29.228000 C 18:57:53 Temperature Measurement, Probe Number = 4, T = 28.000000 C 18:57:54 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007591 V 18:57:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007591 (V, A, ohm, ...), Measured Value = 0.569355 (C, atm, Hz, ...) 18:57:55 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003117 V 18:57:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003117 (V, A, ohm, ...), Measured Value = 0.233775 (C, atm, Hz, ...) 18:57:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001333 V 18:57:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001333 (V, A, ohm, ...), Measured Value = -0.000226 (C, atm, Hz, ...) 18:57:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 154.04 P1 = MAIN (V), Value = 5.99 P2 = Yoke, Value = 30.36 P3 = Coil, Value = 29.48 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 29.23 P6 = Ambient, Value = 28.00 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 18:57:55 Magnetic Field Measurement Measuring the magnet strength... 18:57:55 Integrated Voltage Measurement... 18:57:56 Magnet Current for MAIN, Imag = 154.0515 A Vtrans = 1.540447 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004370221 Vs 18:58:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004360981 Vs 18:58:13 Magnet Current for MAIN, Imag = 154.0422 A Vtrans = 1.540354 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:58:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004370903 Vs 18:58:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004364048 Vs 18:58:29 Magnet Current for MAIN, Imag = 154.0638 A Vtrans = 1.540570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:58:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004368119 Vs 18:58:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004362100 Vs 18:58:46 Magnet Current for MAIN, Imag = 154.0528 A Vtrans = 1.540460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:58:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004371763 Vs 18:59:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004362186 Vs 18:59:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004366290 +- 0.000000967 Vs 18:59:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004366290 +- 0.000000967 Vs BL = -0.05457863 +- 0.00001209 Tm 18:59:05 Position moved: 0.000000 m 18:59:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05458 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05458 0.00001 -0.05458 0.00000 18:59:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05458 0.00001 SL = -0.0545786 +- 0.0000121 Tm^2/m^n 18:59:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0545786 +- 0.0000121 Tm^2/m^n 18:59:08 Position moved: 0.000000 m 18:59:08 Magnet system MAIN current ramping to 168.0000 A... 18:59:23 Magnet Current for MAIN, Imag = 167.9860 A Vtrans = 1.679792 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:59:23 MAIN (V) Voltage Measurement, V = 6.524596 V 18:59:24 Temperature Measurement, Probe Number = 0, T = 30.323000 C 18:59:25 Temperature Measurement, Probe Number = 1, T = 29.580000 C 18:59:25 Temperature Measurement, Probe Number = 2, T = 28.579000 C 18:59:26 Temperature Measurement, Probe Number = 3, T = 29.410000 C 18:59:26 Temperature Measurement, Probe Number = 4, T = 28.021000 C 18:59:27 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007528 V 18:59:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007528 (V, A, ohm, ...), Measured Value = 0.564608 (C, atm, Hz, ...) 18:59:28 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003017 V 18:59:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003017 (V, A, ohm, ...), Measured Value = 0.226312 (C, atm, Hz, ...) 18:59:28 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003126 V 18:59:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003126 (V, A, ohm, ...), Measured Value = -0.000531 (C, atm, Hz, ...) 18:59:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 167.99 P1 = MAIN (V), Value = 6.52 P2 = Yoke, Value = 30.32 P3 = Coil, Value = 29.58 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 29.41 P6 = Ambient, Value = 28.02 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 18:59:28 Magnetic Field Measurement Measuring the magnet strength... 18:59:28 Integrated Voltage Measurement... 18:59:29 Magnet Current for MAIN, Imag = 167.9954 A Vtrans = 1.679885 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004760058 Vs 18:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004754945 Vs 18:59:47 Magnet Current for MAIN, Imag = 168.0012 A Vtrans = 1.679944 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 18:59:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004760727 Vs 19:00:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004752619 Vs 19:00:03 Magnet Current for MAIN, Imag = 167.9894 A Vtrans = 1.679826 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:00:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004760758 Vs 19:00:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004756852 Vs 19:00:20 Magnet Current for MAIN, Imag = 167.9820 A Vtrans = 1.679752 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:00:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004765899 Vs 19:00:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004753125 Vs 19:00:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004758123 +- 0.000001105 Vs 19:00:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004758123 +- 0.000001105 Vs BL = -0.05947654 +- 0.00001381 Tm 19:00:40 Position moved: 0.000000 m 19:00:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05948 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05948 0.00001 -0.05948 0.00000 19:00:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05948 0.00001 SL = -0.0594765 +- 0.0000138 Tm^2/m^n 19:00:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0594765 +- 0.0000138 Tm^2/m^n 19:00:43 Position moved: 0.000000 m 19:00:43 Magnet system MAIN current ramping to 182.0000 A... 19:00:58 Magnet Current for MAIN, Imag = 181.9490 A Vtrans = 1.819422 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:00:58 MAIN (V) Voltage Measurement, V = 7.058630 V 19:00:59 Temperature Measurement, Probe Number = 0, T = 30.297000 C 19:00:59 Temperature Measurement, Probe Number = 1, T = 29.693000 C 19:01:00 Temperature Measurement, Probe Number = 2, T = 28.578000 C 19:01:01 Temperature Measurement, Probe Number = 3, T = 29.576000 C 19:01:01 Temperature Measurement, Probe Number = 4, T = 28.025000 C 19:01:02 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007627 V 19:01:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007627 (V, A, ohm, ...), Measured Value = 0.572062 (C, atm, Hz, ...) 19:01:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002922 V 19:01:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002922 (V, A, ohm, ...), Measured Value = 0.219143 (C, atm, Hz, ...) 19:01:03 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000598 V 19:01:03 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000598 (V, A, ohm, ...), Measured Value = -0.000101 (C, atm, Hz, ...) 19:01:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 181.95 P1 = MAIN (V), Value = 7.06 P2 = Yoke, Value = 30.30 P3 = Coil, Value = 29.69 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 29.58 P6 = Ambient, Value = 28.02 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:01:03 Magnetic Field Measurement Measuring the magnet strength... 19:01:03 Integrated Voltage Measurement... 19:01:04 Magnet Current for MAIN, Imag = 181.9389 A Vtrans = 1.819321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005151504 Vs 19:01:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005148202 Vs 19:01:22 Magnet Current for MAIN, Imag = 181.9514 A Vtrans = 1.819446 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:01:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005152395 Vs 19:01:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005146776 Vs 19:01:38 Magnet Current for MAIN, Imag = 181.9320 A Vtrans = 1.819252 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:01:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005153404 Vs 19:01:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005144746 Vs 19:01:55 Magnet Current for MAIN, Imag = 181.9336 A Vtrans = 1.819268 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:02:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005152270 Vs 19:02:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005144785 Vs 19:02:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005149260 +- 0.000000507 Vs 19:02:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005149260 +- 0.000000507 Vs BL = -0.06436575 +- 0.00000634 Tm 19:02:15 Position moved: 0.000000 m 19:02:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06437 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06437 0.00001 -0.06437 0.00000 19:02:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06437 0.00001 SL = -0.0643658 +- 0.0000063 Tm^2/m^n 19:02:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0643658 +- 0.0000063 Tm^2/m^n 19:02:18 Position moved: 0.000000 m 19:02:18 Magnet system MAIN current ramping to 196.0000 A... 19:02:33 Magnet Current for MAIN, Imag = 196.0264 A Vtrans = 1.960196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:02:33 MAIN (V) Voltage Measurement, V = 7.603779 V 19:02:34 Temperature Measurement, Probe Number = 0, T = 30.277000 C 19:02:34 Temperature Measurement, Probe Number = 1, T = 29.807000 C 19:02:35 Temperature Measurement, Probe Number = 2, T = 28.577000 C 19:02:36 Temperature Measurement, Probe Number = 3, T = 29.774000 C 19:02:36 Temperature Measurement, Probe Number = 4, T = 28.036000 C 19:02:37 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007553 V 19:02:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007553 (V, A, ohm, ...), Measured Value = 0.566445 (C, atm, Hz, ...) 19:02:37 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003042 V 19:02:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003042 (V, A, ohm, ...), Measured Value = 0.228150 (C, atm, Hz, ...) 19:02:38 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000652 V 19:02:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000652 (V, A, ohm, ...), Measured Value = -0.000111 (C, atm, Hz, ...) 19:02:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 196.03 P1 = MAIN (V), Value = 7.60 P2 = Yoke, Value = 30.28 P3 = Coil, Value = 29.81 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 29.77 P6 = Ambient, Value = 28.04 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:02:38 Magnetic Field Measurement Measuring the magnet strength... 19:02:38 Integrated Voltage Measurement... 19:02:39 Magnet Current for MAIN, Imag = 196.0266 A Vtrans = 1.960198 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:02:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005546561 Vs 19:02:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005538941 Vs 19:02:56 Magnet Current for MAIN, Imag = 196.0246 A Vtrans = 1.960178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005545896 Vs 19:03:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005536608 Vs 19:03:12 Magnet Current for MAIN, Imag = 196.0255 A Vtrans = 1.960187 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:03:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005551177 Vs 19:03:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005537327 Vs 19:03:29 Magnet Current for MAIN, Imag = 196.0252 A Vtrans = 1.960184 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:03:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005546620 Vs 19:03:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005538633 Vs 19:03:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005542720 +- 0.000001062 Vs 19:03:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005542720 +- 0.000001062 Vs BL = -0.06928400 +- 0.00001328 Tm 19:03:48 Position moved: 0.000000 m 19:03:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06928 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06928 0.00001 -0.06928 0.00000 19:03:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06928 0.00001 SL = -0.0692840 +- 0.0000133 Tm^2/m^n 19:03:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0692840 +- 0.0000133 Tm^2/m^n 19:03:51 Position moved: 0.000000 m 19:03:51 Magnet system MAIN current ramping to 210.0000 A... 19:04:06 Magnet Current for MAIN, Imag = 209.9873 A Vtrans = 2.099805 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:04:06 MAIN (V) Voltage Measurement, V = 8.144593 V 19:04:07 Temperature Measurement, Probe Number = 0, T = 30.270000 C 19:04:08 Temperature Measurement, Probe Number = 1, T = 29.933000 C 19:04:08 Temperature Measurement, Probe Number = 2, T = 28.583000 C 19:04:09 Temperature Measurement, Probe Number = 3, T = 29.996000 C 19:04:09 Temperature Measurement, Probe Number = 4, T = 28.026000 C 19:04:10 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007532 V 19:04:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007532 (V, A, ohm, ...), Measured Value = 0.564900 (C, atm, Hz, ...) 19:04:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002906 V 19:04:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002906 (V, A, ohm, ...), Measured Value = 0.217980 (C, atm, Hz, ...) 19:04:11 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000069 V 19:04:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000069 (V, A, ohm, ...), Measured Value = 0.000012 (C, atm, Hz, ...) 19:04:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 209.99 P1 = MAIN (V), Value = 8.14 P2 = Yoke, Value = 30.27 P3 = Coil, Value = 29.93 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 30.00 P6 = Ambient, Value = 28.03 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = 0.00 19:04:11 Magnetic Field Measurement Measuring the magnet strength... 19:04:11 Integrated Voltage Measurement... 19:04:12 Magnet Current for MAIN, Imag = 209.9864 A Vtrans = 2.099796 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:04:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005934073 Vs 19:04:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005928122 Vs 19:04:30 Magnet Current for MAIN, Imag = 209.9859 A Vtrans = 2.099791 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:04:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005932726 Vs 19:04:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005925655 Vs 19:04:46 Magnet Current for MAIN, Imag = 209.9806 A Vtrans = 2.099738 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:04:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005931871 Vs 19:05:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005927804 Vs 19:05:03 Magnet Current for MAIN, Imag = 209.9878 A Vtrans = 2.099810 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005939287 Vs 19:05:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005927224 Vs 19:05:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005930845 +- 0.000001551 Vs 19:05:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005930845 +- 0.000001551 Vs BL = -0.07413557 +- 0.00001939 Tm 19:05:23 Position moved: 0.000000 m 19:05:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07414 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07414 0.00002 -0.07414 0.00000 19:05:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07414 0.00002 SL = -0.0741356 +- 0.0000194 Tm^2/m^n 19:05:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0741356 +- 0.0000194 Tm^2/m^n 19:05:26 Position moved: 0.000000 m 19:05:26 Magnet system MAIN current ramping to 224.0000 A... 19:05:40 Magnet Current for MAIN, Imag = 224.1002 A Vtrans = 2.240934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:05:41 MAIN (V) Voltage Measurement, V = 8.692360 V 19:05:42 Temperature Measurement, Probe Number = 0, T = 30.248000 C 19:05:42 Temperature Measurement, Probe Number = 1, T = 30.075000 C 19:05:43 Temperature Measurement, Probe Number = 2, T = 28.581000 C 19:05:43 Temperature Measurement, Probe Number = 3, T = 30.241000 C 19:05:44 Temperature Measurement, Probe Number = 4, T = 28.041000 C 19:05:45 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007549 V 19:05:45 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007549 (V, A, ohm, ...), Measured Value = 0.566153 (C, atm, Hz, ...) 19:05:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002865 V 19:05:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002865 (V, A, ohm, ...), Measured Value = 0.214882 (C, atm, Hz, ...) 19:05:46 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000594 V 19:05:46 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000594 (V, A, ohm, ...), Measured Value = -0.000101 (C, atm, Hz, ...) 19:05:46 Magnet Test Parameter Measurements P0 = MAIN, Value = 224.10 P1 = MAIN (V), Value = 8.69 P2 = Yoke, Value = 30.25 P3 = Coil, Value = 30.07 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 30.24 P6 = Ambient, Value = 28.04 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 19:05:46 Magnetic Field Measurement Measuring the magnet strength... 19:05:46 Integrated Voltage Measurement... 19:05:47 Magnet Current for MAIN, Imag = 224.1180 A Vtrans = 2.241112 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:05:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006327453 Vs 19:06:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006321847 Vs 19:06:05 Magnet Current for MAIN, Imag = 224.0934 A Vtrans = 2.240865 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:06:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006334319 Vs 19:06:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006316589 Vs 19:06:21 Magnet Current for MAIN, Imag = 224.0937 A Vtrans = 2.240869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006328029 Vs 19:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006319672 Vs 19:06:37 Magnet Current for MAIN, Imag = 224.0851 A Vtrans = 2.240783 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006328847 Vs 19:06:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006321863 Vs 19:06:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006324827 +- 0.000000643 Vs 19:06:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006324827 +- 0.000000643 Vs BL = -0.07906034 +- 0.00000804 Tm 19:06:57 Position moved: 0.000000 m 19:06:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07906 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07906 0.00001 -0.07906 0.00000 19:06:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07906 0.00001 SL = -0.0790603 +- 0.0000080 Tm^2/m^n 19:06:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0790603 +- 0.0000080 Tm^2/m^n 19:07:00 Position moved: 0.000000 m 19:07:00 Magnet system MAIN current ramping to 238.0000 A... 19:07:15 Magnet Current for MAIN, Imag = 238.0316 A Vtrans = 2.380248 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:07:15 MAIN (V) Voltage Measurement, V = 9.229856 V 19:07:16 Temperature Measurement, Probe Number = 0, T = 30.241000 C 19:07:17 Temperature Measurement, Probe Number = 1, T = 30.223000 C 19:07:17 Temperature Measurement, Probe Number = 2, T = 28.581000 C 19:07:18 Temperature Measurement, Probe Number = 3, T = 30.486000 C 19:07:18 Temperature Measurement, Probe Number = 4, T = 28.032000 C 19:07:19 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007576 V 19:07:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007576 (V, A, ohm, ...), Measured Value = 0.568192 (C, atm, Hz, ...) 19:07:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002995 V 19:07:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002995 (V, A, ohm, ...), Measured Value = 0.224662 (C, atm, Hz, ...) 19:07:20 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001377 V 19:07:20 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001377 (V, A, ohm, ...), Measured Value = -0.000234 (C, atm, Hz, ...) 19:07:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 238.03 P1 = MAIN (V), Value = 9.23 P2 = Yoke, Value = 30.24 P3 = Coil, Value = 30.22 P4 = H20_In, Value = 28.58 P5 = H2O_Out, Value = 30.49 P6 = Ambient, Value = 28.03 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:07:20 Magnetic Field Measurement Measuring the magnet strength... 19:07:20 Integrated Voltage Measurement... 19:07:21 Magnet Current for MAIN, Imag = 238.0355 A Vtrans = 2.380287 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:07:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006712062 Vs 19:07:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006704544 Vs 19:07:39 Magnet Current for MAIN, Imag = 238.0223 A Vtrans = 2.380155 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:07:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006714555 Vs 19:07:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006704168 Vs 19:07:55 Magnet Current for MAIN, Imag = 238.0272 A Vtrans = 2.380204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:08:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006712736 Vs 19:08:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006707254 Vs 19:08:11 Magnet Current for MAIN, Imag = 238.0169 A Vtrans = 2.380101 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:08:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006712477 Vs 19:08:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006703470 Vs 19:08:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006708908 +- 0.000000810 Vs 19:08:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006708908 +- 0.000000810 Vs BL = -0.08386135 +- 0.00001013 Tm 19:08:31 Position moved: 0.000000 m 19:08:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08386 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08386 0.00001 -0.08386 0.00000 19:08:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08386 0.00001 SL = -0.0838614 +- 0.0000101 Tm^2/m^n 19:08:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0838614 +- 0.0000101 Tm^2/m^n 19:08:34 Position moved: 0.000000 m 19:08:34 Magnet system MAIN current ramping to 252.0000 A... 19:08:49 Magnet Current for MAIN, Imag = 251.9841 A Vtrans = 2.519773 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:08:49 MAIN (V) Voltage Measurement, V = 9.762054 V 19:08:50 Temperature Measurement, Probe Number = 0, T = 30.229000 C 19:08:50 Temperature Measurement, Probe Number = 1, T = 30.378000 C 19:08:51 Temperature Measurement, Probe Number = 2, T = 28.591000 C 19:08:52 Temperature Measurement, Probe Number = 3, T = 30.772000 C 19:08:52 Temperature Measurement, Probe Number = 4, T = 27.984000 C 19:08:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007541 V 19:08:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007541 (V, A, ohm, ...), Measured Value = 0.565575 (C, atm, Hz, ...) 19:08:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003099 V 19:08:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003099 (V, A, ohm, ...), Measured Value = 0.232417 (C, atm, Hz, ...) 19:08:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004670 V 19:08:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004670 (V, A, ohm, ...), Measured Value = -0.000793 (C, atm, Hz, ...) 19:08:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 251.98 P1 = MAIN (V), Value = 9.76 P2 = Yoke, Value = 30.23 P3 = Coil, Value = 30.38 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 30.77 P6 = Ambient, Value = 27.98 P7 = Supply Pres(psi), Value = 0.57 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:08:54 Magnetic Field Measurement Measuring the magnet strength... 19:08:54 Integrated Voltage Measurement... 19:08:55 Magnet Current for MAIN, Imag = 251.9815 A Vtrans = 2.519747 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:09:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007098285 Vs 19:09:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007088869 Vs 19:09:12 Magnet Current for MAIN, Imag = 251.9910 A Vtrans = 2.519842 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:09:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007094655 Vs 19:09:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007086895 Vs 19:09:28 Magnet Current for MAIN, Imag = 251.9869 A Vtrans = 2.519801 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:09:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007100749 Vs 19:09:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007091933 Vs 19:09:45 Magnet Current for MAIN, Imag = 251.9848 A Vtrans = 2.519780 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:09:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007096646 Vs 19:10:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007086993 Vs 19:10:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007093128 +- 0.000002108 Vs 19:10:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007093128 +- 0.000002108 Vs BL = -0.08866410 +- 0.00002635 Tm 19:10:04 Position moved: 0.000000 m 19:10:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08866 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08866 0.00003 -0.08866 0.00000 19:10:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08866 0.00003 SL = -0.0886641 +- 0.0000263 Tm^2/m^n 19:10:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0886641 +- 0.0000263 Tm^2/m^n 19:10:07 Position moved: 0.000000 m 19:10:07 Magnet system MAIN current ramping to 266.0000 A... 19:10:22 Magnet Current for MAIN, Imag = 266.0931 A Vtrans = 2.660863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:10:22 MAIN (V) Voltage Measurement, V = 10.312788 V 19:10:23 Temperature Measurement, Probe Number = 0, T = 30.217000 C 19:10:24 Temperature Measurement, Probe Number = 1, T = 30.550000 C 19:10:24 Temperature Measurement, Probe Number = 2, T = 28.594000 C 19:10:25 Temperature Measurement, Probe Number = 3, T = 31.051000 C 19:10:26 Temperature Measurement, Probe Number = 4, T = 27.998000 C 19:10:26 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007458 V 19:10:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007458 (V, A, ohm, ...), Measured Value = 0.559372 (C, atm, Hz, ...) 19:10:27 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003054 V 19:10:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003054 (V, A, ohm, ...), Measured Value = 0.229027 (C, atm, Hz, ...) 19:10:27 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000664 V 19:10:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000664 (V, A, ohm, ...), Measured Value = -0.000113 (C, atm, Hz, ...) 19:10:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 266.09 P1 = MAIN (V), Value = 10.31 P2 = Yoke, Value = 30.22 P3 = Coil, Value = 30.55 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 31.05 P6 = Ambient, Value = 28.00 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:10:28 Magnetic Field Measurement Measuring the magnet strength... 19:10:28 Integrated Voltage Measurement... 19:10:28 Magnet Current for MAIN, Imag = 266.1415 A Vtrans = 2.661347 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:10:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007472793 Vs 19:10:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007470202 Vs 19:10:46 Magnet Current for MAIN, Imag = 266.0991 A Vtrans = 2.660923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:10:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007473277 Vs 19:11:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007472044 Vs 19:11:02 Magnet Current for MAIN, Imag = 266.0938 A Vtrans = 2.660870 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:11:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007471318 Vs 19:11:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007469788 Vs 19:11:18 Magnet Current for MAIN, Imag = 266.0925 A Vtrans = 2.660857 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:11:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007480922 Vs 19:11:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007469511 Vs 19:11:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007472482 +- 0.000001746 Vs 19:11:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007472482 +- 0.000001746 Vs BL = -0.09340602 +- 0.00002183 Tm 19:11:38 Position moved: 0.000000 m 19:11:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09341 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09341 0.00002 -0.09341 0.00000 19:11:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09341 0.00002 SL = -0.0934060 +- 0.0000218 Tm^2/m^n 19:11:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0934060 +- 0.0000218 Tm^2/m^n 19:11:40 Position moved: 0.000000 m 19:11:40 Magnet system MAIN current ramping to 280.0000 A... 19:11:55 Magnet Current for MAIN, Imag = 280.0447 A Vtrans = 2.800379 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:11:56 MAIN (V) Voltage Measurement, V = 10.859452 V 19:11:56 Temperature Measurement, Probe Number = 0, T = 30.214000 C 19:11:57 Temperature Measurement, Probe Number = 1, T = 30.720000 C 19:11:58 Temperature Measurement, Probe Number = 2, T = 28.595000 C 19:11:58 Temperature Measurement, Probe Number = 3, T = 31.309000 C 19:11:59 Temperature Measurement, Probe Number = 4, T = 27.984000 C 19:11:59 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007527 V 19:11:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007527 (V, A, ohm, ...), Measured Value = 0.564510 (C, atm, Hz, ...) 19:12:00 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003179 V 19:12:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003179 (V, A, ohm, ...), Measured Value = 0.238425 (C, atm, Hz, ...) 19:12:01 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003971 V 19:12:01 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003971 (V, A, ohm, ...), Measured Value = -0.000674 (C, atm, Hz, ...) 19:12:01 Magnet Test Parameter Measurements P0 = MAIN, Value = 280.04 P1 = MAIN (V), Value = 10.86 P2 = Yoke, Value = 30.21 P3 = Coil, Value = 30.72 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 31.31 P6 = Ambient, Value = 27.98 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.24 P9 = Flow Rate(gpm), Value = -0.00 19:12:01 Magnetic Field Measurement Measuring the magnet strength... 19:12:01 Integrated Voltage Measurement... 19:12:02 Magnet Current for MAIN, Imag = 280.0298 A Vtrans = 2.800230 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:12:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007839066 Vs 19:12:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007839063 Vs 19:12:19 Magnet Current for MAIN, Imag = 280.0354 A Vtrans = 2.800286 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:12:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007841311 Vs 19:12:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007840546 Vs 19:12:35 Magnet Current for MAIN, Imag = 280.0468 A Vtrans = 2.800400 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007845950 Vs 19:12:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007840047 Vs 19:12:52 Magnet Current for MAIN, Imag = 280.0410 A Vtrans = 2.800342 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:12:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007840703 Vs 19:13:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007836857 Vs 19:13:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007840443 +- 0.000001691 Vs 19:13:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007840443 +- 0.000001691 Vs BL = -0.09800553 +- 0.00002114 Tm 19:13:11 Position moved: 0.000000 m 19:13:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09801 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09801 0.00002 -0.09801 0.00000 19:13:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09801 0.00002 SL = -0.0980055 +- 0.0000211 Tm^2/m^n 19:13:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0980055 +- 0.0000211 Tm^2/m^n 19:13:14 Position moved: 0.000000 m 19:13:14 Magnet system MAIN current ramping to 294.0000 A... 19:13:29 Magnet Current for MAIN, Imag = 293.9989 A Vtrans = 2.939921 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:13:29 MAIN (V) Voltage Measurement, V = 11.408116 V 19:13:30 Temperature Measurement, Probe Number = 0, T = 30.220000 C 19:13:31 Temperature Measurement, Probe Number = 1, T = 30.906000 C 19:13:31 Temperature Measurement, Probe Number = 2, T = 28.600000 C 19:13:32 Temperature Measurement, Probe Number = 3, T = 31.595000 C 19:13:32 Temperature Measurement, Probe Number = 4, T = 27.989000 C 19:13:33 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007452 V 19:13:33 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007452 (V, A, ohm, ...), Measured Value = 0.558892 (C, atm, Hz, ...) 19:13:34 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002995 V 19:13:34 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002995 (V, A, ohm, ...), Measured Value = 0.224662 (C, atm, Hz, ...) 19:13:34 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004709 V 19:13:34 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004709 (V, A, ohm, ...), Measured Value = -0.000800 (C, atm, Hz, ...) 19:13:34 Magnet Test Parameter Measurements P0 = MAIN, Value = 294.00 P1 = MAIN (V), Value = 11.41 P2 = Yoke, Value = 30.22 P3 = Coil, Value = 30.91 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 31.59 P6 = Ambient, Value = 27.99 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:13:34 Magnetic Field Measurement Measuring the magnet strength... 19:13:34 Integrated Voltage Measurement... 19:13:35 Magnet Current for MAIN, Imag = 293.9972 A Vtrans = 2.939904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:13:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008192454 Vs 19:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008182538 Vs 19:13:53 Magnet Current for MAIN, Imag = 294.0007 A Vtrans = 2.939939 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:14:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008197251 Vs 19:14:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008184033 Vs 19:14:09 Magnet Current for MAIN, Imag = 293.9937 A Vtrans = 2.939869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:14:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008193322 Vs 19:14:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008184516 Vs 19:14:25 Magnet Current for MAIN, Imag = 293.9972 A Vtrans = 2.939904 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:14:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008197709 Vs 19:14:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008184611 Vs 19:14:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008189554 +- 0.000001449 Vs 19:14:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008189554 +- 0.000001449 Vs BL = -0.10236943 +- 0.00001812 Tm 19:14:45 Position moved: 0.000000 m 19:14:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10237 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10237 0.00002 -0.10237 0.00000 19:14:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10237 0.00002 SL = -0.1023694 +- 0.0000181 Tm^2/m^n 19:14:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1023694 +- 0.0000181 Tm^2/m^n 19:14:48 Position moved: 0.000000 m 19:14:48 Magnet system MAIN current ramping to 308.0000 A... 19:15:02 Magnet Current for MAIN, Imag = 308.0845 A Vtrans = 3.080777 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:15:03 MAIN (V) Voltage Measurement, V = 11.958639 V 19:15:04 Temperature Measurement, Probe Number = 0, T = 30.233000 C 19:15:04 Temperature Measurement, Probe Number = 1, T = 31.111000 C 19:15:05 Temperature Measurement, Probe Number = 2, T = 28.597000 C 19:15:06 Temperature Measurement, Probe Number = 3, T = 31.880000 C 19:15:06 Temperature Measurement, Probe Number = 4, T = 28.018000 C 19:15:07 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007494 V 19:15:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007494 (V, A, ohm, ...), Measured Value = 0.562087 (C, atm, Hz, ...) 19:15:07 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003096 V 19:15:07 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003096 (V, A, ohm, ...), Measured Value = 0.232222 (C, atm, Hz, ...) 19:15:08 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000050 V 19:15:08 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000050 (V, A, ohm, ...), Measured Value = 0.000008 (C, atm, Hz, ...) 19:15:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.08 P1 = MAIN (V), Value = 11.96 P2 = Yoke, Value = 30.23 P3 = Coil, Value = 31.11 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 31.88 P6 = Ambient, Value = 28.02 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = 0.00 19:15:08 Magnetic Field Measurement Measuring the magnet strength... 19:15:08 Integrated Voltage Measurement... 19:15:09 Magnet Current for MAIN, Imag = 308.1100 A Vtrans = 3.081032 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:15:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008517693 Vs 19:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008500341 Vs 19:15:26 Magnet Current for MAIN, Imag = 308.0872 A Vtrans = 3.080804 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:15:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008506770 Vs 19:15:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008504382 Vs 19:15:43 Magnet Current for MAIN, Imag = 308.0809 A Vtrans = 3.080741 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:15:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008511603 Vs 19:15:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008503815 Vs 19:15:59 Magnet Current for MAIN, Imag = 308.0866 A Vtrans = 3.080798 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:16:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008511176 Vs 19:16:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008500013 Vs 19:16:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008506974 +- 0.000001464 Vs 19:16:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008506974 +- 0.000001464 Vs BL = -0.10633718 +- 0.00001830 Tm 19:16:19 Position moved: 0.000000 m 19:16:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10634 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10634 0.00002 -0.10634 0.00000 19:16:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10634 0.00002 SL = -0.1063372 +- 0.0000183 Tm^2/m^n 19:16:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1063372 +- 0.0000183 Tm^2/m^n 19:16:22 Position moved: 0.000000 m 19:16:22 Magnet system MAIN current ramping to 322.0000 A... 19:16:37 Magnet Current for MAIN, Imag = 322.0295 A Vtrans = 3.220227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:16:38 MAIN (V) Voltage Measurement, V = 12.512366 V 19:16:38 Temperature Measurement, Probe Number = 0, T = 30.236000 C 19:16:39 Temperature Measurement, Probe Number = 1, T = 31.315000 C 19:16:40 Temperature Measurement, Probe Number = 2, T = 28.610000 C 19:16:40 Temperature Measurement, Probe Number = 3, T = 32.275000 C 19:16:41 Temperature Measurement, Probe Number = 4, T = 28.002000 C 19:16:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007400 V 19:16:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007400 (V, A, ohm, ...), Measured Value = 0.555015 (C, atm, Hz, ...) 19:16:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003028 V 19:16:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003028 (V, A, ohm, ...), Measured Value = 0.227085 (C, atm, Hz, ...) 19:16:43 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001652 V 19:16:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001652 (V, A, ohm, ...), Measured Value = -0.000281 (C, atm, Hz, ...) 19:16:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 322.03 P1 = MAIN (V), Value = 12.51 P2 = Yoke, Value = 30.24 P3 = Coil, Value = 31.32 P4 = H20_In, Value = 28.61 P5 = H2O_Out, Value = 32.27 P6 = Ambient, Value = 28.00 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:16:43 Magnetic Field Measurement Measuring the magnet strength... 19:16:43 Integrated Voltage Measurement... 19:16:44 Magnet Current for MAIN, Imag = 322.0234 A Vtrans = 3.220166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:16:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008791411 Vs 19:17:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008775400 Vs 19:17:01 Magnet Current for MAIN, Imag = 322.0299 A Vtrans = 3.220231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:17:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008794936 Vs 19:17:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008776811 Vs 19:17:18 Magnet Current for MAIN, Imag = 322.0195 A Vtrans = 3.220127 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:17:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008784303 Vs 19:17:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008777066 Vs 19:17:35 Magnet Current for MAIN, Imag = 322.0292 A Vtrans = 3.220224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008796969 Vs 19:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008774557 Vs 19:17:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008783931 +- 0.000002118 Vs 19:17:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008783931 +- 0.000002118 Vs BL = -0.10979914 +- 0.00002648 Tm 19:17:54 Position moved: 0.000000 m 19:17:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10980 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10980 0.00003 -0.10980 0.00000 19:17:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10980 0.00003 SL = -0.1097991 +- 0.0000265 Tm^2/m^n 19:17:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1097991 +- 0.0000265 Tm^2/m^n 19:17:57 Position moved: 0.000000 m 19:17:57 Magnet system MAIN current ramping to 336.0000 A... 19:18:12 Magnet Current for MAIN, Imag = 336.1296 A Vtrans = 3.361228 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:18:13 MAIN (V) Voltage Measurement, V = 13.072599 V 19:18:13 Temperature Measurement, Probe Number = 0, T = 30.249000 C 19:18:14 Temperature Measurement, Probe Number = 1, T = 31.529000 C 19:18:15 Temperature Measurement, Probe Number = 2, T = 28.613000 C 19:18:15 Temperature Measurement, Probe Number = 3, T = 32.688000 C 19:18:16 Temperature Measurement, Probe Number = 4, T = 28.008000 C 19:18:16 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007491 V 19:18:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007491 (V, A, ohm, ...), Measured Value = 0.561795 (C, atm, Hz, ...) 19:18:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003083 V 19:18:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003083 (V, A, ohm, ...), Measured Value = 0.231255 (C, atm, Hz, ...) 19:18:18 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003962 V 19:18:18 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003962 (V, A, ohm, ...), Measured Value = -0.000673 (C, atm, Hz, ...) 19:18:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 336.13 P1 = MAIN (V), Value = 13.07 P2 = Yoke, Value = 30.25 P3 = Coil, Value = 31.53 P4 = H20_In, Value = 28.61 P5 = H2O_Out, Value = 32.69 P6 = Ambient, Value = 28.01 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:18:18 Magnetic Field Measurement Measuring the magnet strength... 19:18:18 Integrated Voltage Measurement... 19:18:19 Magnet Current for MAIN, Imag = 336.1317 A Vtrans = 3.361249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009032425 Vs 19:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009019896 Vs 19:18:36 Magnet Current for MAIN, Imag = 336.1345 A Vtrans = 3.361277 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009029375 Vs 19:18:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009020244 Vs 19:18:52 Magnet Current for MAIN, Imag = 336.1344 A Vtrans = 3.361276 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:19:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009024650 Vs 19:19:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009022610 Vs 19:19:09 Magnet Current for MAIN, Imag = 336.1295 A Vtrans = 3.361227 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:19:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009025338 Vs 19:19:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009021312 Vs 19:19:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009024481 +- 0.000001117 Vs 19:19:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009024481 +- 0.000001117 Vs BL = -0.11280601 +- 0.00001396 Tm 19:19:28 Position moved: 0.000000 m 19:19:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11281 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11281 0.00001 -0.11281 0.00000 19:19:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11281 0.00001 SL = -0.1128060 +- 0.0000140 Tm^2/m^n 19:19:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1128060 +- 0.0000140 Tm^2/m^n 19:19:31 Position moved: 0.000000 m 19:19:31 Magnet system MAIN current ramping to 350.0000 A... 19:19:46 Magnet Current for MAIN, Imag = 350.0579 A Vtrans = 3.500511 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:19:46 MAIN (V) Voltage Measurement, V = 13.629486 V 19:19:47 Temperature Measurement, Probe Number = 0, T = 30.283000 C 19:19:48 Temperature Measurement, Probe Number = 1, T = 31.738000 C 19:19:48 Temperature Measurement, Probe Number = 2, T = 28.620000 C 19:19:49 Temperature Measurement, Probe Number = 3, T = 33.077000 C 19:19:49 Temperature Measurement, Probe Number = 4, T = 27.971000 C 19:19:50 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007443 V 19:19:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007443 (V, A, ohm, ...), Measured Value = 0.558210 (C, atm, Hz, ...) 19:19:51 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003175 V 19:19:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003175 (V, A, ohm, ...), Measured Value = 0.238132 (C, atm, Hz, ...) 19:19:51 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004157 V 19:19:51 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004157 (V, A, ohm, ...), Measured Value = -0.000706 (C, atm, Hz, ...) 19:19:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 350.06 P1 = MAIN (V), Value = 13.63 P2 = Yoke, Value = 30.28 P3 = Coil, Value = 31.74 P4 = H20_In, Value = 28.62 P5 = H2O_Out, Value = 33.08 P6 = Ambient, Value = 27.97 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.24 P9 = Flow Rate(gpm), Value = -0.00 19:19:51 Magnetic Field Measurement Measuring the magnet strength... 19:19:51 Integrated Voltage Measurement... 19:19:52 Magnet Current for MAIN, Imag = 350.0660 A Vtrans = 3.500592 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:20:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009262921 Vs 19:20:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009243943 Vs 19:20:10 Magnet Current for MAIN, Imag = 350.0638 A Vtrans = 3.500570 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:20:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009256358 Vs 19:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009247514 Vs 19:20:26 Magnet Current for MAIN, Imag = 350.0626 A Vtrans = 3.500558 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:20:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009246847 Vs 19:20:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009243460 Vs 19:20:42 Magnet Current for MAIN, Imag = 350.0579 A Vtrans = 3.500511 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:20:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009255008 Vs 19:20:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009243701 Vs 19:20:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009249969 +- 0.000003139 Vs 19:20:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009249969 +- 0.000003139 Vs BL = -0.11562461 +- 0.00003924 Tm 19:21:02 Position moved: 0.000000 m 19:21:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11562 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11562 0.00004 -0.11562 0.00000 19:21:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11562 0.00004 SL = -0.1156246 +- 0.0000392 Tm^2/m^n 19:21:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1156246 +- 0.0000392 Tm^2/m^n Remeasure 19:21:02 Magnetic Field Measurement Measuring the magnet strength... 19:21:02 Integrated Voltage Measurement... 19:21:03 Magnet Current for MAIN, Imag = 350.0592 A Vtrans = 3.500524 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:21:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009249074 Vs 19:21:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009244848 Vs 19:21:21 Magnet Current for MAIN, Imag = 350.0685 A Vtrans = 3.500617 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:21:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009257957 Vs 19:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009242440 Vs 19:21:37 Magnet Current for MAIN, Imag = 350.0706 A Vtrans = 3.500638 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:21:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009266145 Vs 19:21:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009244062 Vs 19:21:54 Magnet Current for MAIN, Imag = 350.0601 A Vtrans = 3.500533 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:22:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009250979 Vs 19:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009242615 Vs 19:22:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009249765 +- 0.000003368 Vs 19:22:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009249765 +- 0.000003368 Vs BL = -0.11562206 +- 0.00004209 Tm 19:22:13 Position moved: 0.000000 m 19:22:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11562 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11562 0.00004 -0.11562 0.00000 19:22:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11562 0.00004 SL = -0.1156221 +- 0.0000421 Tm^2/m^n 19:22:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1156221 +- 0.0000421 Tm^2/m^n 19:22:16 Position moved: 0.000000 m 19:22:16 Magnet system MAIN current ramping to 364.0000 A... 19:22:31 Magnet Current for MAIN, Imag = 364.0246 A Vtrans = 3.640178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:22:32 MAIN (V) Voltage Measurement, V = 14.187698 V 19:22:32 Temperature Measurement, Probe Number = 0, T = 30.335000 C 19:22:33 Temperature Measurement, Probe Number = 1, T = 32.087000 C 19:22:34 Temperature Measurement, Probe Number = 2, T = 28.631000 C 19:22:34 Temperature Measurement, Probe Number = 3, T = 33.600000 C 19:22:35 Temperature Measurement, Probe Number = 4, T = 27.968000 C 19:22:35 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007500 V 19:22:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007500 (V, A, ohm, ...), Measured Value = 0.562478 (C, atm, Hz, ...) 19:22:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002886 V 19:22:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002886 (V, A, ohm, ...), Measured Value = 0.216435 (C, atm, Hz, ...) 19:22:37 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002678 V 19:22:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002678 (V, A, ohm, ...), Measured Value = -0.000455 (C, atm, Hz, ...) 19:22:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 364.02 P1 = MAIN (V), Value = 14.19 P2 = Yoke, Value = 30.34 P3 = Coil, Value = 32.09 P4 = H20_In, Value = 28.63 P5 = H2O_Out, Value = 33.60 P6 = Ambient, Value = 27.97 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:22:37 Magnetic Field Measurement Measuring the magnet strength... 19:22:37 Integrated Voltage Measurement... 19:22:38 Magnet Current for MAIN, Imag = 364.0337 A Vtrans = 3.640269 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:22:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009471934 Vs 19:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009451546 Vs 19:22:55 Magnet Current for MAIN, Imag = 364.0328 A Vtrans = 3.640260 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009469339 Vs 19:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009450038 Vs 19:23:12 Magnet Current for MAIN, Imag = 364.0303 A Vtrans = 3.640235 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:23:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009465368 Vs 19:23:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009453870 Vs 19:23:28 Magnet Current for MAIN, Imag = 364.0275 A Vtrans = 3.640207 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:23:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009470403 Vs 19:23:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009454091 Vs 19:23:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009460824 +- 0.000001184 Vs 19:23:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009460824 +- 0.000001184 Vs BL = -0.11826030 +- 0.00001480 Tm 19:23:48 Position moved: 0.000000 m 19:23:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11826 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11826 0.00001 -0.11826 0.00000 19:23:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11826 0.00001 SL = -0.1182603 +- 0.0000148 Tm^2/m^n 19:23:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1182603 +- 0.0000148 Tm^2/m^n 19:23:51 Position moved: 0.000000 m 19:23:51 Magnet system MAIN current ramping to 378.0000 A... 19:24:06 Magnet Current for MAIN, Imag = 378.1332 A Vtrans = 3.781264 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:24:07 MAIN (V) Voltage Measurement, V = 14.753674 V 19:24:07 Temperature Measurement, Probe Number = 0, T = 30.364000 C 19:24:08 Temperature Measurement, Probe Number = 1, T = 32.300000 C 19:24:08 Temperature Measurement, Probe Number = 2, T = 28.632000 C 19:24:09 Temperature Measurement, Probe Number = 3, T = 33.980000 C 19:24:10 Temperature Measurement, Probe Number = 4, T = 27.957000 C 19:24:10 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007516 V 19:24:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007516 (V, A, ohm, ...), Measured Value = 0.563737 (C, atm, Hz, ...) 19:24:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002968 V 19:24:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002968 (V, A, ohm, ...), Measured Value = 0.222630 (C, atm, Hz, ...) 19:24:11 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000320 V 19:24:11 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000320 (V, A, ohm, ...), Measured Value = 0.000054 (C, atm, Hz, ...) 19:24:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 378.13 P1 = MAIN (V), Value = 14.75 P2 = Yoke, Value = 30.36 P3 = Coil, Value = 32.30 P4 = H20_In, Value = 28.63 P5 = H2O_Out, Value = 33.98 P6 = Ambient, Value = 27.96 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = 0.00 19:24:12 Magnetic Field Measurement Measuring the magnet strength... 19:24:12 Integrated Voltage Measurement... 19:24:12 Magnet Current for MAIN, Imag = 378.1193 A Vtrans = 3.781125 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:24:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009672981 Vs 19:24:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009656831 Vs 19:24:30 Magnet Current for MAIN, Imag = 378.1504 A Vtrans = 3.781436 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:24:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009680099 Vs 19:24:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009656123 Vs 19:24:46 Magnet Current for MAIN, Imag = 378.1221 A Vtrans = 3.781153 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:24:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009675255 Vs 19:25:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009657566 Vs 19:25:03 Magnet Current for MAIN, Imag = 378.1386 A Vtrans = 3.781318 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:25:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009664094 Vs 19:25:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009666104 Vs 19:25:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009666132 +- 0.000001281 Vs 19:25:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009666132 +- 0.000001281 Vs BL = -0.12082665 +- 0.00001601 Tm 19:25:22 Position moved: 0.000000 m 19:25:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.12083 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.12083 0.00002 -0.12083 0.00000 19:25:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.12083 0.00002 SL = -0.1208266 +- 0.0000160 Tm^2/m^n 19:25:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1208266 +- 0.0000160 Tm^2/m^n 19:25:25 Position moved: 0.000000 m 19:25:25 Magnet system MAIN current ramping to 380.0000 A... 19:25:36 Magnet Current for MAIN, Imag = 380.0753 A Vtrans = 3.800685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:25:37 MAIN (V) Voltage Measurement, V = 14.833651 V 19:25:38 Temperature Measurement, Probe Number = 0, T = 30.409000 C 19:25:38 Temperature Measurement, Probe Number = 1, T = 32.526000 C 19:25:39 Temperature Measurement, Probe Number = 2, T = 28.619000 C 19:25:39 Temperature Measurement, Probe Number = 3, T = 34.350000 C 19:25:40 Temperature Measurement, Probe Number = 4, T = 27.951000 C 19:25:41 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007487 V 19:25:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007487 (V, A, ohm, ...), Measured Value = 0.561503 (C, atm, Hz, ...) 19:25:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002891 V 19:25:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002891 (V, A, ohm, ...), Measured Value = 0.216817 (C, atm, Hz, ...) 19:25:42 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000074 V 19:25:42 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000074 (V, A, ohm, ...), Measured Value = -0.000013 (C, atm, Hz, ...) 19:25:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 380.08 P1 = MAIN (V), Value = 14.83 P2 = Yoke, Value = 30.41 P3 = Coil, Value = 32.53 P4 = H20_In, Value = 28.62 P5 = H2O_Out, Value = 34.35 P6 = Ambient, Value = 27.95 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:25:42 Magnetic Field Measurement Measuring the magnet strength... 19:25:42 Integrated Voltage Measurement... 19:25:43 Magnet Current for MAIN, Imag = 380.0870 A Vtrans = 3.800802 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:25:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009693458 Vs 19:25:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009691407 Vs 19:26:00 Magnet Current for MAIN, Imag = 380.0732 A Vtrans = 3.800664 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:26:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009696882 Vs 19:26:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009686838 Vs 19:26:16 Magnet Current for MAIN, Imag = 380.0935 A Vtrans = 3.800867 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:26:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009703644 Vs 19:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009689329 Vs 19:26:33 Magnet Current for MAIN, Imag = 380.0741 A Vtrans = 3.800673 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:26:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009687271 Vs 19:26:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009688223 Vs 19:26:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009692132 +- 0.000003096 Vs 19:26:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009692132 +- 0.000003096 Vs BL = -0.12115164 +- 0.00003871 Tm 19:26:52 Position moved: 0.000000 m 19:26:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.12115 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.12115 0.00004 -0.12115 0.00000 19:26:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.12115 0.00004 SL = -0.1211516 +- 0.0000387 Tm^2/m^n 19:26:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1211516 +- 0.0000387 Tm^2/m^n Remeasure 19:26:52 Magnetic Field Measurement Measuring the magnet strength... 19:26:52 Integrated Voltage Measurement... 19:26:53 Magnet Current for MAIN, Imag = 380.0753 A Vtrans = 3.800685 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:27:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009697782 Vs 19:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009687184 Vs 19:27:10 Magnet Current for MAIN, Imag = 380.0891 A Vtrans = 3.800823 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:27:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009703996 Vs 19:27:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009688317 Vs 19:27:26 Magnet Current for MAIN, Imag = 380.0788 A Vtrans = 3.800720 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:27:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009698911 Vs 19:27:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009688496 Vs 19:27:43 Magnet Current for MAIN, Imag = 380.0751 A Vtrans = 3.800683 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:27:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009699036 Vs 19:27:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009688863 Vs 19:27:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009694073 +- 0.000001325 Vs 19:27:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009694073 +- 0.000001325 Vs BL = -0.12117592 +- 0.00001656 Tm 19:28:02 Position moved: 0.000000 m 19:28:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.12118 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.12118 0.00002 -0.12118 0.00000 19:28:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.12118 0.00002 SL = -0.1211759 +- 0.0000166 Tm^2/m^n 19:28:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1211759 +- 0.0000166 Tm^2/m^n 19:28:05 Position moved: 0.000000 m 19:28:05 Magnet system MAIN current ramping to 378.0000 A... 19:28:16 Magnet Current for MAIN, Imag = 378.1323 A Vtrans = 3.781255 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:28:17 MAIN (V) Voltage Measurement, V = 14.754568 V 19:28:18 Temperature Measurement, Probe Number = 0, T = 30.486000 C 19:28:18 Temperature Measurement, Probe Number = 1, T = 32.742000 C 19:28:19 Temperature Measurement, Probe Number = 2, T = 28.623000 C 19:28:20 Temperature Measurement, Probe Number = 3, T = 34.751000 C 19:28:20 Temperature Measurement, Probe Number = 4, T = 27.961000 C 19:28:21 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007476 V 19:28:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007476 (V, A, ohm, ...), Measured Value = 0.560730 (C, atm, Hz, ...) 19:28:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002921 V 19:28:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002921 (V, A, ohm, ...), Measured Value = 0.219045 (C, atm, Hz, ...) 19:28:22 Sensor Voltage Measurement, Sensor Number = 2, V = -0.004141 V 19:28:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.004141 (V, A, ohm, ...), Measured Value = -0.000703 (C, atm, Hz, ...) 19:28:22 Magnet Test Parameter Measurements P0 = MAIN, Value = 378.13 P1 = MAIN (V), Value = 14.75 P2 = Yoke, Value = 30.49 P3 = Coil, Value = 32.74 P4 = H20_In, Value = 28.62 P5 = H2O_Out, Value = 34.75 P6 = Ambient, Value = 27.96 P7 = Supply Pres(psi), Value = 0.56 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:28:22 Magnetic Field Measurement Measuring the magnet strength... 19:28:22 Integrated Voltage Measurement... 19:28:23 Magnet Current for MAIN, Imag = 378.1268 A Vtrans = 3.781200 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:28:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009670046 Vs 19:28:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009662020 Vs 19:28:41 Magnet Current for MAIN, Imag = 378.1278 A Vtrans = 3.781210 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:28:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009670898 Vs 19:28:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009661968 Vs 19:28:57 Magnet Current for MAIN, Imag = 378.1246 A Vtrans = 3.781178 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:29:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009661067 Vs 19:29:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009660583 Vs 19:29:14 Magnet Current for MAIN, Imag = 378.1209 A Vtrans = 3.781141 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:29:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009670240 Vs 19:29:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009660203 Vs 19:29:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009664628 +- 0.000002239 Vs 19:29:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009664628 +- 0.000002239 Vs BL = -0.12080785 +- 0.00002798 Tm 19:29:34 Position moved: 0.000000 m 19:29:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.12081 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.12081 0.00003 -0.12081 0.00000 19:29:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.12081 0.00003 SL = -0.1208079 +- 0.0000280 Tm^2/m^n 19:29:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1208079 +- 0.0000280 Tm^2/m^n 19:29:37 Position moved: 0.000000 m 19:29:37 Magnet system MAIN current ramping to 364.0000 A... 19:29:51 Magnet Current for MAIN, Imag = 364.0234 A Vtrans = 3.640166 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:29:52 MAIN (V) Voltage Measurement, V = 14.183886 V 19:29:53 Temperature Measurement, Probe Number = 0, T = 30.533000 C 19:29:53 Temperature Measurement, Probe Number = 1, T = 32.762000 C 19:29:54 Temperature Measurement, Probe Number = 2, T = 28.626000 C 19:29:54 Temperature Measurement, Probe Number = 3, T = 34.777000 C 19:29:55 Temperature Measurement, Probe Number = 4, T = 27.951000 C 19:29:56 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007332 V 19:29:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007332 (V, A, ohm, ...), Measured Value = 0.549877 (C, atm, Hz, ...) 19:29:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002956 V 19:29:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002956 (V, A, ohm, ...), Measured Value = 0.221663 (C, atm, Hz, ...) 19:29:57 Sensor Voltage Measurement, Sensor Number = 2, V = -0.022866 V 19:29:57 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.022866 (V, A, ohm, ...), Measured Value = -0.003883 (C, atm, Hz, ...) 19:29:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 364.02 P1 = MAIN (V), Value = 14.18 P2 = Yoke, Value = 30.53 P3 = Coil, Value = 32.76 P4 = H20_In, Value = 28.63 P5 = H2O_Out, Value = 34.78 P6 = Ambient, Value = 27.95 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:29:57 Magnetic Field Measurement Measuring the magnet strength... 19:29:57 Integrated Voltage Measurement... 19:29:58 Magnet Current for MAIN, Imag = 364.0099 A Vtrans = 3.640030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:30:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009469434 Vs 19:30:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009467561 Vs 19:30:16 Magnet Current for MAIN, Imag = 364.0557 A Vtrans = 3.640489 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:30:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009469907 Vs 19:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009469330 Vs 19:30:33 Magnet Current for MAIN, Imag = 364.0190 A Vtrans = 3.640122 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:30:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009482078 Vs 19:30:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009467008 Vs 19:30:49 Magnet Current for MAIN, Imag = 364.0197 A Vtrans = 3.640129 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:30:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009490989 Vs 19:31:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009465377 Vs 19:31:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009472711 +- 0.000003893 Vs 19:31:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009472711 +- 0.000003893 Vs BL = -0.11840888 +- 0.00004866 Tm 19:31:09 Position moved: 0.000000 m 19:31:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11841 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11841 0.00005 -0.11841 0.00000 19:31:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11841 0.00005 SL = -0.1184089 +- 0.0000487 Tm^2/m^n 19:31:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1184089 +- 0.0000487 Tm^2/m^n Remeasure 19:31:09 Magnetic Field Measurement Measuring the magnet strength... 19:31:09 Integrated Voltage Measurement... 19:31:10 Magnet Current for MAIN, Imag = 364.0323 A Vtrans = 3.640255 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009480916 Vs 19:31:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009471351 Vs 19:31:28 Magnet Current for MAIN, Imag = 364.0310 A Vtrans = 3.640242 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:31:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009468412 Vs 19:31:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009464774 Vs 19:31:44 Magnet Current for MAIN, Imag = 364.0314 A Vtrans = 3.640246 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:31:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009473803 Vs 19:32:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009463608 Vs 19:32:00 Magnet Current for MAIN, Imag = 364.0225 A Vtrans = 3.640157 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009481818 Vs 19:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009470122 Vs 19:32:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009471851 +- 0.000004268 Vs 19:32:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009471851 +- 0.000004268 Vs BL = -0.11839813 +- 0.00005334 Tm 19:32:20 Position moved: 0.000000 m 19:32:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11840 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11840 0.00005 -0.11840 0.00000 19:32:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11840 0.00005 SL = -0.1183981 +- 0.0000533 Tm^2/m^n 19:32:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1183981 +- 0.0000533 Tm^2/m^n Remeasure 19:32:20 Magnetic Field Measurement Measuring the magnet strength... 19:32:20 Integrated Voltage Measurement... 19:32:21 Magnet Current for MAIN, Imag = 364.0220 A Vtrans = 3.640152 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:32:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009484535 Vs 19:32:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009461378 Vs 19:32:38 Magnet Current for MAIN, Imag = 364.0309 A Vtrans = 3.640241 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:32:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009485920 Vs 19:32:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009467917 Vs 19:32:55 Magnet Current for MAIN, Imag = 364.0233 A Vtrans = 3.640165 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:33:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009470896 Vs 19:33:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009460327 Vs 19:33:11 Magnet Current for MAIN, Imag = 364.0260 A Vtrans = 3.640192 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:33:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009467483 Vs 19:33:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009468209 Vs 19:33:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009470833 +- 0.000004408 Vs 19:33:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009470833 +- 0.000004408 Vs BL = -0.11838541 +- 0.00005510 Tm 19:33:31 Position moved: 0.000000 m 19:33:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11839 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11839 0.00006 -0.11839 0.00000 19:33:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11839 0.00006 SL = -0.1183854 +- 0.0000551 Tm^2/m^n 19:33:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1183854 +- 0.0000551 Tm^2/m^n 19:33:34 Position moved: 0.000000 m 19:33:34 Magnet system MAIN current ramping to 350.0000 A... 19:33:49 Magnet Current for MAIN, Imag = 350.0588 A Vtrans = 3.500520 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:33:50 MAIN (V) Voltage Measurement, V = 13.625597 V 19:33:50 Temperature Measurement, Probe Number = 0, T = 30.629000 C 19:33:51 Temperature Measurement, Probe Number = 1, T = 32.575000 C 19:33:51 Temperature Measurement, Probe Number = 2, T = 28.628000 C 19:33:52 Temperature Measurement, Probe Number = 3, T = 34.498000 C 19:33:53 Temperature Measurement, Probe Number = 4, T = 27.912000 C 19:33:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007307 V 19:33:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007307 (V, A, ohm, ...), Measured Value = 0.548040 (C, atm, Hz, ...) 19:33:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002899 V 19:33:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002899 (V, A, ohm, ...), Measured Value = 0.217403 (C, atm, Hz, ...) 19:33:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001870 V 19:33:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001870 (V, A, ohm, ...), Measured Value = -0.000318 (C, atm, Hz, ...) 19:33:55 Magnet Test Parameter Measurements P0 = MAIN, Value = 350.06 P1 = MAIN (V), Value = 13.63 P2 = Yoke, Value = 30.63 P3 = Coil, Value = 32.58 P4 = H20_In, Value = 28.63 P5 = H2O_Out, Value = 34.50 P6 = Ambient, Value = 27.91 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:33:55 Magnetic Field Measurement Measuring the magnet strength... 19:33:55 Integrated Voltage Measurement... 19:33:56 Magnet Current for MAIN, Imag = 350.0573 A Vtrans = 3.500504 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:34:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009261622 Vs 19:34:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009263108 Vs 19:34:13 Magnet Current for MAIN, Imag = 350.0595 A Vtrans = 3.500526 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:34:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009270537 Vs 19:34:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009262528 Vs 19:34:30 Magnet Current for MAIN, Imag = 350.0618 A Vtrans = 3.500550 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:34:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009268984 Vs 19:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009263332 Vs 19:34:46 Magnet Current for MAIN, Imag = 350.0591 A Vtrans = 3.500523 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:34:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009270661 Vs 19:35:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009264020 Vs 19:35:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009265599 +- 0.000001915 Vs 19:35:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009265599 +- 0.000001915 Vs BL = -0.11581999 +- 0.00002394 Tm 19:35:06 Position moved: 0.000000 m 19:35:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11582 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11582 0.00002 -0.11582 0.00000 19:35:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11582 0.00002 SL = -0.1158200 +- 0.0000239 Tm^2/m^n 19:35:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1158200 +- 0.0000239 Tm^2/m^n 19:35:09 Position moved: 0.000000 m 19:35:09 Magnet system MAIN current ramping to 336.0000 A... 19:35:24 Magnet Current for MAIN, Imag = 336.1105 A Vtrans = 3.361037 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:35:25 MAIN (V) Voltage Measurement, V = 13.072120 V 19:35:25 Temperature Measurement, Probe Number = 0, T = 30.667000 C 19:35:26 Temperature Measurement, Probe Number = 1, T = 32.438000 C 19:35:27 Temperature Measurement, Probe Number = 2, T = 28.620000 C 19:35:27 Temperature Measurement, Probe Number = 3, T = 34.254000 C 19:35:28 Temperature Measurement, Probe Number = 4, T = 27.937000 C 19:35:28 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007293 V 19:35:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007293 (V, A, ohm, ...), Measured Value = 0.546975 (C, atm, Hz, ...) 19:35:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002923 V 19:35:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002923 (V, A, ohm, ...), Measured Value = 0.219240 (C, atm, Hz, ...) 19:35:30 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001463 V 19:35:30 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001463 (V, A, ohm, ...), Measured Value = -0.000249 (C, atm, Hz, ...) 19:35:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 336.11 P1 = MAIN (V), Value = 13.07 P2 = Yoke, Value = 30.67 P3 = Coil, Value = 32.44 P4 = H20_In, Value = 28.62 P5 = H2O_Out, Value = 34.25 P6 = Ambient, Value = 27.94 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:35:30 Magnetic Field Measurement Measuring the magnet strength... 19:35:30 Integrated Voltage Measurement... 19:35:31 Magnet Current for MAIN, Imag = 336.1930 A Vtrans = 3.361862 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:35:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009046094 Vs 19:35:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009048554 Vs 19:35:48 Magnet Current for MAIN, Imag = 336.1291 A Vtrans = 3.361223 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:35:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009042348 Vs 19:36:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009052070 Vs 19:36:05 Magnet Current for MAIN, Imag = 336.1367 A Vtrans = 3.361299 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:36:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009061875 Vs 19:36:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009044078 Vs 19:36:21 Magnet Current for MAIN, Imag = 336.1357 A Vtrans = 3.361289 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:36:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009044980 Vs 19:36:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.009047863 Vs 19:36:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.009048483 +- 0.000002618 Vs 19:36:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.009048483 +- 0.000002618 Vs BL = -0.11310603 +- 0.00003272 Tm 19:36:41 Position moved: 0.000000 m 19:36:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11311 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11311 0.00003 -0.11311 0.00000 19:36:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11311 0.00003 SL = -0.1131060 +- 0.0000327 Tm^2/m^n 19:36:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1131060 +- 0.0000327 Tm^2/m^n 19:36:44 Position moved: 0.000000 m 19:36:44 Magnet system MAIN current ramping to 322.0000 A... 19:36:59 Magnet Current for MAIN, Imag = 322.0340 A Vtrans = 3.220272 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:36:59 MAIN (V) Voltage Measurement, V = 12.507789 V 19:37:00 Temperature Measurement, Probe Number = 0, T = 30.700000 C 19:37:00 Temperature Measurement, Probe Number = 1, T = 32.240000 C 19:37:01 Temperature Measurement, Probe Number = 2, T = 28.604000 C 19:37:02 Temperature Measurement, Probe Number = 3, T = 33.864000 C 19:37:02 Temperature Measurement, Probe Number = 4, T = 27.923000 C 19:37:03 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007367 V 19:37:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007367 (V, A, ohm, ...), Measured Value = 0.552495 (C, atm, Hz, ...) 19:37:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002813 V 19:37:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002813 (V, A, ohm, ...), Measured Value = 0.211005 (C, atm, Hz, ...) 19:37:04 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001097 V 19:37:04 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001097 (V, A, ohm, ...), Measured Value = -0.000186 (C, atm, Hz, ...) 19:37:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 322.03 P1 = MAIN (V), Value = 12.51 P2 = Yoke, Value = 30.70 P3 = Coil, Value = 32.24 P4 = H20_In, Value = 28.60 P5 = H2O_Out, Value = 33.86 P6 = Ambient, Value = 27.92 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 19:37:04 Magnetic Field Measurement Measuring the magnet strength... 19:37:04 Integrated Voltage Measurement... 19:37:05 Magnet Current for MAIN, Imag = 322.0424 A Vtrans = 3.220356 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008816345 Vs 19:37:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008812458 Vs 19:37:23 Magnet Current for MAIN, Imag = 322.0433 A Vtrans = 3.220365 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008829826 Vs 19:37:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008809123 Vs 19:37:39 Magnet Current for MAIN, Imag = 322.0566 A Vtrans = 3.220498 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:37:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008829281 Vs 19:37:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008805671 Vs 19:37:55 Magnet Current for MAIN, Imag = 322.0310 A Vtrans = 3.220242 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008807283 Vs 19:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008806987 Vs 19:38:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008814622 +- 0.000004685 Vs 19:38:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008814622 +- 0.000004685 Vs BL = -0.11018277 +- 0.00005856 Tm 19:38:15 Position moved: 0.000000 m 19:38:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11018 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11018 0.00006 -0.11018 0.00000 19:38:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11018 0.00006 SL = -0.1101828 +- 0.0000586 Tm^2/m^n 19:38:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1101828 +- 0.0000586 Tm^2/m^n Remeasure 19:38:15 Magnetic Field Measurement Measuring the magnet strength... 19:38:16 Integrated Voltage Measurement... 19:38:16 Magnet Current for MAIN, Imag = 322.0247 A Vtrans = 3.220179 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:38:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008819497 Vs 19:38:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008812688 Vs 19:38:34 Magnet Current for MAIN, Imag = 322.0277 A Vtrans = 3.220209 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:38:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008832807 Vs 19:38:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008809927 Vs 19:38:50 Magnet Current for MAIN, Imag = 322.0464 A Vtrans = 3.220396 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:38:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008804816 Vs 19:39:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008810338 Vs 19:39:06 Magnet Current for MAIN, Imag = 322.0974 A Vtrans = 3.220906 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:39:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008838830 Vs 19:39:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008810998 Vs 19:39:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008817488 +- 0.000006526 Vs 19:39:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008817488 +- 0.000006526 Vs BL = -0.11021860 +- 0.00008158 Tm 19:39:26 Position moved: 0.000000 m 19:39:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11022 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11022 0.00008 -0.11022 0.00000 19:39:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11022 0.00008 SL = -0.1102186 +- 0.0000816 Tm^2/m^n 19:39:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1102186 +- 0.0000816 Tm^2/m^n Remeasure 19:39:26 Magnetic Field Measurement Measuring the magnet strength... 19:39:26 Integrated Voltage Measurement... 19:39:27 Magnet Current for MAIN, Imag = 322.0397 A Vtrans = 3.220329 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:39:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008816785 Vs 19:39:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008809250 Vs 19:39:44 Magnet Current for MAIN, Imag = 322.0389 A Vtrans = 3.220321 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:39:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008814916 Vs 19:39:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008811232 Vs 19:40:00 Magnet Current for MAIN, Imag = 322.0281 A Vtrans = 3.220213 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:40:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008811507 Vs 19:40:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008811695 Vs 19:40:17 Magnet Current for MAIN, Imag = 322.0525 A Vtrans = 3.220457 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:40:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008826520 Vs 19:40:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008809188 Vs 19:40:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008813887 +- 0.000002365 Vs 19:40:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008813887 +- 0.000002365 Vs BL = -0.11017358 +- 0.00002957 Tm 19:40:36 Position moved: 0.000000 m 19:40:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.11017 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.11017 0.00003 -0.11017 0.00000 19:40:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.11017 0.00003 SL = -0.1101736 +- 0.0000296 Tm^2/m^n 19:40:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1101736 +- 0.0000296 Tm^2/m^n 19:40:39 Position moved: 0.000000 m 19:40:39 Magnet system MAIN current ramping to 308.0000 A... 19:40:54 Magnet Current for MAIN, Imag = 308.1248 A Vtrans = 3.081180 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:40:55 MAIN (V) Voltage Measurement, V = 11.967666 V 19:40:55 Temperature Measurement, Probe Number = 0, T = 30.759000 C 19:40:56 Temperature Measurement, Probe Number = 1, T = 31.890000 C 19:40:56 Temperature Measurement, Probe Number = 2, T = 28.592000 C 19:40:57 Temperature Measurement, Probe Number = 3, T = 33.234000 C 19:40:58 Temperature Measurement, Probe Number = 4, T = 27.943000 C 19:40:58 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007329 V 19:40:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007329 (V, A, ohm, ...), Measured Value = 0.549690 (C, atm, Hz, ...) 19:40:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002974 V 19:40:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002974 (V, A, ohm, ...), Measured Value = 0.223020 (C, atm, Hz, ...) 19:41:00 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001321 V 19:41:00 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001321 (V, A, ohm, ...), Measured Value = -0.000224 (C, atm, Hz, ...) 19:41:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 308.12 P1 = MAIN (V), Value = 11.97 P2 = Yoke, Value = 30.76 P3 = Coil, Value = 31.89 P4 = H20_In, Value = 28.59 P5 = H2O_Out, Value = 33.23 P6 = Ambient, Value = 27.94 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:41:00 Magnetic Field Measurement Measuring the magnet strength... 19:41:00 Integrated Voltage Measurement... 19:41:00 Magnet Current for MAIN, Imag = 308.0937 A Vtrans = 3.080869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:41:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008538348 Vs 19:41:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008560169 Vs 19:41:18 Magnet Current for MAIN, Imag = 308.0932 A Vtrans = 3.080864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:41:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008562436 Vs 19:41:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008552372 Vs 19:41:34 Magnet Current for MAIN, Imag = 308.0986 A Vtrans = 3.080918 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:41:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008559643 Vs 19:41:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008555536 Vs 19:41:51 Magnet Current for MAIN, Imag = 308.0791 A Vtrans = 3.080723 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:41:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008543625 Vs 19:42:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008557454 Vs 19:42:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008553698 +- 0.000003826 Vs 19:42:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008553698 +- 0.000003826 Vs BL = -0.10692122 +- 0.00004783 Tm 19:42:10 Position moved: 0.000000 m 19:42:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10692 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10692 0.00005 -0.10692 0.00000 19:42:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10692 0.00005 SL = -0.1069212 +- 0.0000478 Tm^2/m^n 19:42:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1069212 +- 0.0000478 Tm^2/m^n Remeasure 19:42:10 Magnetic Field Measurement Measuring the magnet strength... 19:42:10 Integrated Voltage Measurement... 19:42:11 Magnet Current for MAIN, Imag = 308.0994 A Vtrans = 3.080926 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:42:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008554445 Vs 19:42:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008555532 Vs 19:42:28 Magnet Current for MAIN, Imag = 308.0825 A Vtrans = 3.080757 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:42:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008547828 Vs 19:42:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008558061 Vs 19:42:45 Magnet Current for MAIN, Imag = 308.0768 A Vtrans = 3.080700 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:42:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008563653 Vs 19:43:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008554005 Vs 19:43:01 Magnet Current for MAIN, Imag = 308.1036 A Vtrans = 3.080968 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:43:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008571390 Vs 19:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008553662 Vs 19:43:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008557322 +- 0.000003673 Vs 19:43:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008557322 +- 0.000003673 Vs BL = -0.10696652 +- 0.00004591 Tm 19:43:20 Position moved: 0.000000 m 19:43:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10697 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10697 0.00005 -0.10697 0.00000 19:43:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10697 0.00005 SL = -0.1069665 +- 0.0000459 Tm^2/m^n 19:43:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1069665 +- 0.0000459 Tm^2/m^n Remeasure 19:43:20 Magnetic Field Measurement Measuring the magnet strength... 19:43:20 Integrated Voltage Measurement... 19:43:21 Magnet Current for MAIN, Imag = 308.0934 A Vtrans = 3.080866 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:43:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008547402 Vs 19:43:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008554061 Vs 19:43:39 Magnet Current for MAIN, Imag = 308.1292 A Vtrans = 3.081224 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:43:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008552321 Vs 19:43:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008556041 Vs 19:43:55 Magnet Current for MAIN, Imag = 308.0834 A Vtrans = 3.080766 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:44:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008552037 Vs 19:44:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008556777 Vs 19:44:11 Magnet Current for MAIN, Imag = 308.1346 A Vtrans = 3.081278 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:44:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008566214 Vs 19:44:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008556154 Vs 19:44:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008555126 +- 0.000003789 Vs 19:44:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008555126 +- 0.000003789 Vs BL = -0.10693907 +- 0.00004736 Tm 19:44:31 Position moved: 0.000000 m 19:44:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10694 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10694 0.00005 -0.10694 0.00000 19:44:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10694 0.00005 SL = -0.1069391 +- 0.0000474 Tm^2/m^n 19:44:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1069391 +- 0.0000474 Tm^2/m^n 19:44:33 Position moved: 0.000000 m 19:44:33 Magnet system MAIN current ramping to 294.0000 A... 19:44:48 Magnet Current for MAIN, Imag = 294.0016 A Vtrans = 2.939948 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:44:49 MAIN (V) Voltage Measurement, V = 11.414162 V 19:44:49 Temperature Measurement, Probe Number = 0, T = 30.792000 C 19:44:50 Temperature Measurement, Probe Number = 1, T = 31.627000 C 19:44:51 Temperature Measurement, Probe Number = 2, T = 28.574000 C 19:44:51 Temperature Measurement, Probe Number = 3, T = 32.768000 C 19:44:52 Temperature Measurement, Probe Number = 4, T = 27.961000 C 19:44:53 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007310 V 19:44:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007310 (V, A, ohm, ...), Measured Value = 0.548235 (C, atm, Hz, ...) 19:44:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003023 V 19:44:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003023 (V, A, ohm, ...), Measured Value = 0.226703 (C, atm, Hz, ...) 19:44:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001653 V 19:44:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001653 (V, A, ohm, ...), Measured Value = -0.000281 (C, atm, Hz, ...) 19:44:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 294.00 P1 = MAIN (V), Value = 11.41 P2 = Yoke, Value = 30.79 P3 = Coil, Value = 31.63 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.77 P6 = Ambient, Value = 27.96 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:44:54 Magnetic Field Measurement Measuring the magnet strength... 19:44:54 Integrated Voltage Measurement... 19:44:55 Magnet Current for MAIN, Imag = 293.9999 A Vtrans = 2.939931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:45:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008236351 Vs 19:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008242338 Vs 19:45:12 Magnet Current for MAIN, Imag = 293.9981 A Vtrans = 2.939913 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008255205 Vs 19:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008246639 Vs 19:45:29 Magnet Current for MAIN, Imag = 293.9937 A Vtrans = 2.939869 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:45:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008248043 Vs 19:45:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008242966 Vs 19:45:46 Magnet Current for MAIN, Imag = 293.9891 A Vtrans = 2.939823 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:45:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008245837 Vs 19:46:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008244729 Vs 19:46:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008245263 +- 0.000004096 Vs 19:46:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008245263 +- 0.000004096 Vs BL = -0.10306579 +- 0.00005120 Tm 19:46:06 Position moved: 0.000000 m 19:46:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10307 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10307 0.00005 -0.10307 0.00000 19:46:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10307 0.00005 SL = -0.1030658 +- 0.0000512 Tm^2/m^n 19:46:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1030658 +- 0.0000512 Tm^2/m^n Remeasure 19:46:06 Magnetic Field Measurement Measuring the magnet strength... 19:46:06 Integrated Voltage Measurement... 19:46:07 Magnet Current for MAIN, Imag = 293.9878 A Vtrans = 2.939810 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:46:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008250393 Vs 19:46:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008248453 Vs 19:46:24 Magnet Current for MAIN, Imag = 293.9958 A Vtrans = 2.939890 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:46:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008250318 Vs 19:46:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008251066 Vs 19:46:41 Magnet Current for MAIN, Imag = 293.9878 A Vtrans = 2.939810 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:46:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008250883 Vs 19:46:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008248142 Vs 19:46:58 Magnet Current for MAIN, Imag = 293.9932 A Vtrans = 2.939864 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:47:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008245410 Vs 19:47:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.008242352 Vs 19:47:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.008248377 +- 0.000002643 Vs 19:47:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.008248377 +- 0.000002643 Vs BL = -0.10310471 +- 0.00003304 Tm 19:47:17 Position moved: 0.000000 m 19:47:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.10310 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.10310 0.00003 -0.10310 0.00000 19:47:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.10310 0.00003 SL = -0.1031047 +- 0.0000330 Tm^2/m^n 19:47:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.1031047 +- 0.0000330 Tm^2/m^n 19:47:20 Position moved: 0.000000 m 19:47:20 Magnet system MAIN current ramping to 280.0000 A... 19:47:35 Magnet Current for MAIN, Imag = 280.0670 A Vtrans = 2.800602 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:47:36 MAIN (V) Voltage Measurement, V = 10.863550 V 19:47:37 Temperature Measurement, Probe Number = 0, T = 30.818000 C 19:47:37 Temperature Measurement, Probe Number = 1, T = 31.415000 C 19:47:38 Temperature Measurement, Probe Number = 2, T = 28.570000 C 19:47:38 Temperature Measurement, Probe Number = 3, T = 32.478000 C 19:47:39 Temperature Measurement, Probe Number = 4, T = 27.924000 C 19:47:40 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007293 V 19:47:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007293 (V, A, ohm, ...), Measured Value = 0.546975 (C, atm, Hz, ...) 19:47:40 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002838 V 19:47:40 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002838 (V, A, ohm, ...), Measured Value = 0.212850 (C, atm, Hz, ...) 19:47:41 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000192 V 19:47:41 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000192 (V, A, ohm, ...), Measured Value = -0.000033 (C, atm, Hz, ...) 19:47:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 280.07 P1 = MAIN (V), Value = 10.86 P2 = Yoke, Value = 30.82 P3 = Coil, Value = 31.41 P4 = H20_In, Value = 28.57 P5 = H2O_Out, Value = 32.48 P6 = Ambient, Value = 27.92 P7 = Supply Pres(psi), Value = 0.55 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 19:47:41 Magnetic Field Measurement Measuring the magnet strength... 19:47:41 Integrated Voltage Measurement... 19:47:42 Magnet Current for MAIN, Imag = 280.0560 A Vtrans = 2.800492 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:47:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007900698 Vs 19:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007894323 Vs 19:48:00 Magnet Current for MAIN, Imag = 280.0557 A Vtrans = 2.800489 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:48:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007886681 Vs 19:48:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007894511 Vs 19:48:16 Magnet Current for MAIN, Imag = 280.0645 A Vtrans = 2.800577 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:48:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007890447 Vs 19:48:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007893584 Vs 19:48:33 Magnet Current for MAIN, Imag = 280.0533 A Vtrans = 2.800465 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:48:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007904604 Vs 19:48:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007890438 Vs 19:48:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007894411 +- 0.000003145 Vs 19:48:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007894411 +- 0.000003145 Vs BL = -0.09868013 +- 0.00003932 Tm 19:48:52 Position moved: 0.000000 m 19:48:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09868 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09868 0.00004 -0.09868 0.00000 19:48:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09868 0.00004 SL = -0.0986801 +- 0.0000393 Tm^2/m^n 19:48:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0986801 +- 0.0000393 Tm^2/m^n Remeasure 19:48:52 Magnetic Field Measurement Measuring the magnet strength... 19:48:52 Integrated Voltage Measurement... 19:48:53 Magnet Current for MAIN, Imag = 280.0507 A Vtrans = 2.800439 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007910220 Vs 19:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007896149 Vs 19:49:10 Magnet Current for MAIN, Imag = 280.0584 A Vtrans = 2.800516 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007888372 Vs 19:49:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007896877 Vs 19:49:27 Magnet Current for MAIN, Imag = 280.0605 A Vtrans = 2.800537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:49:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007894387 Vs 19:49:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007897191 Vs 19:49:43 Magnet Current for MAIN, Imag = 280.0564 A Vtrans = 2.800496 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:49:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007899457 Vs 19:49:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007899464 Vs 19:49:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007897765 +- 0.000003955 Vs 19:49:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007897765 +- 0.000003955 Vs BL = -0.09872206 +- 0.00004944 Tm 19:50:02 Position moved: 0.000000 m 19:50:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09872 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09872 0.00005 -0.09872 0.00000 19:50:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09872 0.00005 SL = -0.0987221 +- 0.0000494 Tm^2/m^n 19:50:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0987221 +- 0.0000494 Tm^2/m^n Remeasure 19:50:03 Magnetic Field Measurement Measuring the magnet strength... 19:50:03 Integrated Voltage Measurement... 19:50:03 Magnet Current for MAIN, Imag = 280.0590 A Vtrans = 2.800521 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:50:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007897702 Vs 19:50:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007894721 Vs 19:50:21 Magnet Current for MAIN, Imag = 280.0742 A Vtrans = 2.800674 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:50:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007892487 Vs 19:50:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007895700 Vs 19:50:37 Magnet Current for MAIN, Imag = 280.0565 A Vtrans = 2.800497 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:50:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007896290 Vs 19:50:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007895451 Vs 19:50:54 Magnet Current for MAIN, Imag = 280.0511 A Vtrans = 2.800443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:51:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007894537 Vs 19:51:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007892825 Vs 19:51:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007894964 +- 0.000001093 Vs 19:51:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007894964 +- 0.000001093 Vs BL = -0.09868705 +- 0.00001367 Tm 19:51:14 Position moved: 0.000000 m 19:51:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09869 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09869 0.00001 -0.09869 0.00000 19:51:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09869 0.00001 SL = -0.0986871 +- 0.0000137 Tm^2/m^n 19:51:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0986871 +- 0.0000137 Tm^2/m^n 19:51:17 Position moved: 0.000000 m 19:51:17 Magnet system MAIN current ramping to 266.0000 A... 19:51:32 Magnet Current for MAIN, Imag = 266.1013 A Vtrans = 2.660945 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:51:32 MAIN (V) Voltage Measurement, V = 10.318276 V 19:51:33 Temperature Measurement, Probe Number = 0, T = 30.829000 C 19:51:34 Temperature Measurement, Probe Number = 1, T = 31.182000 C 19:51:34 Temperature Measurement, Probe Number = 2, T = 28.550000 C 19:51:35 Temperature Measurement, Probe Number = 3, T = 32.078000 C 19:51:36 Temperature Measurement, Probe Number = 4, T = 27.899000 C 19:51:36 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007219 V 19:51:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007219 (V, A, ohm, ...), Measured Value = 0.541455 (C, atm, Hz, ...) 19:51:37 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002837 V 19:51:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002837 (V, A, ohm, ...), Measured Value = 0.212753 (C, atm, Hz, ...) 19:51:37 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001001 V 19:51:37 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001001 (V, A, ohm, ...), Measured Value = -0.000170 (C, atm, Hz, ...) 19:51:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 266.10 P1 = MAIN (V), Value = 10.32 P2 = Yoke, Value = 30.83 P3 = Coil, Value = 31.18 P4 = H20_In, Value = 28.55 P5 = H2O_Out, Value = 32.08 P6 = Ambient, Value = 27.90 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 19:51:38 Magnetic Field Measurement Measuring the magnet strength... 19:51:38 Integrated Voltage Measurement... 19:51:38 Magnet Current for MAIN, Imag = 266.1040 A Vtrans = 2.660972 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:51:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007533508 Vs 19:51:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007522555 Vs 19:51:56 Magnet Current for MAIN, Imag = 266.1084 A Vtrans = 2.661016 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:52:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007525785 Vs 19:52:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007519367 Vs 19:52:13 Magnet Current for MAIN, Imag = 266.0935 A Vtrans = 2.660867 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:52:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007520412 Vs 19:52:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007517754 Vs 19:52:29 Magnet Current for MAIN, Imag = 266.1250 A Vtrans = 2.661182 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:52:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007519254 Vs 19:52:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007515284 Vs 19:52:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007521740 +- 0.000004103 Vs 19:52:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007521740 +- 0.000004103 Vs BL = -0.09402175 +- 0.00005128 Tm 19:52:49 Position moved: 0.000000 m 19:52:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09402 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09402 0.00005 -0.09402 0.00000 19:52:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09402 0.00005 SL = -0.0940217 +- 0.0000513 Tm^2/m^n 19:52:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0940217 +- 0.0000513 Tm^2/m^n Remeasure 19:52:49 Magnetic Field Measurement Measuring the magnet strength... 19:52:49 Integrated Voltage Measurement... 19:52:50 Magnet Current for MAIN, Imag = 266.1060 A Vtrans = 2.660992 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:52:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007541418 Vs 19:53:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007516879 Vs 19:53:07 Magnet Current for MAIN, Imag = 266.1099 A Vtrans = 2.661030 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007529140 Vs 19:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007517839 Vs 19:53:23 Magnet Current for MAIN, Imag = 266.1132 A Vtrans = 2.661064 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007520566 Vs 19:53:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007514713 Vs 19:53:40 Magnet Current for MAIN, Imag = 266.1077 A Vtrans = 2.661009 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:53:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007517337 Vs 19:53:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007518628 Vs 19:53:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007522065 +- 0.000004703 Vs 19:53:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007522065 +- 0.000004703 Vs BL = -0.09402581 +- 0.00005878 Tm 19:54:00 Position moved: 0.000000 m 19:54:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09403 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09403 0.00006 -0.09403 0.00000 19:54:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09403 0.00006 SL = -0.0940258 +- 0.0000588 Tm^2/m^n 19:54:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0940258 +- 0.0000588 Tm^2/m^n Remeasure 19:54:00 Magnetic Field Measurement Measuring the magnet strength... 19:54:00 Integrated Voltage Measurement... 19:54:00 Magnet Current for MAIN, Imag = 266.1162 A Vtrans = 2.661094 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:54:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007523140 Vs 19:54:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007517611 Vs 19:54:18 Magnet Current for MAIN, Imag = 266.1061 A Vtrans = 2.660993 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:54:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007531749 Vs 19:54:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007517472 Vs 19:54:34 Magnet Current for MAIN, Imag = 266.1082 A Vtrans = 2.661014 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:54:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007533634 Vs 19:54:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007519303 Vs 19:54:50 Magnet Current for MAIN, Imag = 266.1128 A Vtrans = 2.661060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:54:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007529886 Vs 19:55:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007519754 Vs 19:55:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007524069 +- 0.000002250 Vs 19:55:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007524069 +- 0.000002250 Vs BL = -0.09405086 +- 0.00002813 Tm 19:55:10 Position moved: 0.000000 m 19:55:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.09405 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.09405 0.00003 -0.09405 0.00000 19:55:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.09405 0.00003 SL = -0.0940509 +- 0.0000281 Tm^2/m^n 19:55:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0940509 +- 0.0000281 Tm^2/m^n 19:55:13 Position moved: 0.000000 m 19:55:13 Magnet system MAIN current ramping to 252.0000 A... 19:55:28 Magnet Current for MAIN, Imag = 252.0007 A Vtrans = 2.519939 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:55:28 MAIN (V) Voltage Measurement, V = 9.761112 V 19:55:29 Temperature Measurement, Probe Number = 0, T = 30.817000 C 19:55:29 Temperature Measurement, Probe Number = 1, T = 30.969000 C 19:55:30 Temperature Measurement, Probe Number = 2, T = 28.525000 C 19:55:31 Temperature Measurement, Probe Number = 3, T = 31.690000 C 19:55:31 Temperature Measurement, Probe Number = 4, T = 27.910000 C 19:55:32 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007252 V 19:55:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007252 (V, A, ohm, ...), Measured Value = 0.543878 (C, atm, Hz, ...) 19:55:33 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002900 V 19:55:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002900 (V, A, ohm, ...), Measured Value = 0.217500 (C, atm, Hz, ...) 19:55:33 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003589 V 19:55:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003589 (V, A, ohm, ...), Measured Value = -0.000609 (C, atm, Hz, ...) 19:55:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 252.00 P1 = MAIN (V), Value = 9.76 P2 = Yoke, Value = 30.82 P3 = Coil, Value = 30.97 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 31.69 P6 = Ambient, Value = 27.91 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.22 P9 = Flow Rate(gpm), Value = -0.00 19:55:33 Magnetic Field Measurement Measuring the magnet strength... 19:55:33 Integrated Voltage Measurement... 19:55:34 Magnet Current for MAIN, Imag = 251.9881 A Vtrans = 2.519813 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:55:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007136520 Vs 19:55:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007130610 Vs 19:55:51 Magnet Current for MAIN, Imag = 251.9856 A Vtrans = 2.519788 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:55:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007139984 Vs 19:56:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007132604 Vs 19:56:08 Magnet Current for MAIN, Imag = 251.9922 A Vtrans = 2.519854 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:56:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007140886 Vs 19:56:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007133144 Vs 19:56:24 Magnet Current for MAIN, Imag = 251.9910 A Vtrans = 2.519842 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:56:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007133730 Vs 19:56:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.007133480 Vs 19:56:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.007135120 +- 0.000001556 Vs 19:56:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.007135120 +- 0.000001556 Vs BL = -0.08918900 +- 0.00001945 Tm 19:56:43 Position moved: 0.000000 m 19:56:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08919 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08919 0.00002 -0.08919 0.00000 19:56:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08919 0.00002 SL = -0.0891890 +- 0.0000194 Tm^2/m^n 19:56:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0891890 +- 0.0000194 Tm^2/m^n 19:56:46 Position moved: 0.000000 m 19:56:46 Magnet system MAIN current ramping to 238.0000 A... 19:57:01 Magnet Current for MAIN, Imag = 238.0543 A Vtrans = 2.380475 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:57:02 MAIN (V) Voltage Measurement, V = 9.224255 V 19:57:02 Temperature Measurement, Probe Number = 0, T = 30.804000 C 19:57:03 Temperature Measurement, Probe Number = 1, T = 30.844000 C 19:57:04 Temperature Measurement, Probe Number = 2, T = 28.531000 C 19:57:04 Temperature Measurement, Probe Number = 3, T = 31.500000 C 19:57:05 Temperature Measurement, Probe Number = 4, T = 27.907000 C 19:57:05 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007200 V 19:57:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007200 (V, A, ohm, ...), Measured Value = 0.540000 (C, atm, Hz, ...) 19:57:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.003021 V 19:57:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.003021 (V, A, ohm, ...), Measured Value = 0.226605 (C, atm, Hz, ...) 19:57:07 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000338 V 19:57:07 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000338 (V, A, ohm, ...), Measured Value = -0.000057 (C, atm, Hz, ...) 19:57:07 Magnet Test Parameter Measurements P0 = MAIN, Value = 238.05 P1 = MAIN (V), Value = 9.22 P2 = Yoke, Value = 30.80 P3 = Coil, Value = 30.84 P4 = H20_In, Value = 28.53 P5 = H2O_Out, Value = 31.50 P6 = Ambient, Value = 27.91 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.23 P9 = Flow Rate(gpm), Value = -0.00 19:57:07 Magnetic Field Measurement Measuring the magnet strength... 19:57:07 Integrated Voltage Measurement... 19:57:08 Magnet Current for MAIN, Imag = 238.0344 A Vtrans = 2.380276 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:57:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006757749 Vs 19:57:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006747265 Vs 19:57:25 Magnet Current for MAIN, Imag = 238.0492 A Vtrans = 2.380424 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:57:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006752000 Vs 19:57:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006748035 Vs 19:57:41 Magnet Current for MAIN, Imag = 238.0307 A Vtrans = 2.380239 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:57:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006747858 Vs 19:57:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006748270 Vs 19:57:58 Magnet Current for MAIN, Imag = 238.0189 A Vtrans = 2.380121 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006761523 Vs 19:58:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006751768 Vs 19:58:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006751809 +- 0.000003206 Vs 19:58:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006751809 +- 0.000003206 Vs BL = -0.08439761 +- 0.00004007 Tm 19:58:17 Position moved: 0.000000 m 19:58:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08440 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08440 0.00004 -0.08440 0.00000 19:58:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08440 0.00004 SL = -0.0843976 +- 0.0000401 Tm^2/m^n 19:58:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0843976 +- 0.0000401 Tm^2/m^n Remeasure 19:58:17 Magnetic Field Measurement Measuring the magnet strength... 19:58:17 Integrated Voltage Measurement... 19:58:18 Magnet Current for MAIN, Imag = 238.0129 A Vtrans = 2.380060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:58:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006754261 Vs 19:58:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006746673 Vs 19:58:35 Magnet Current for MAIN, Imag = 238.0309 A Vtrans = 2.380241 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:58:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006750260 Vs 19:58:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006749715 Vs 19:58:52 Magnet Current for MAIN, Imag = 238.0303 A Vtrans = 2.380235 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:59:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006739586 Vs 19:59:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006746619 Vs 19:59:08 Magnet Current for MAIN, Imag = 238.0264 A Vtrans = 2.380196 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:59:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006748110 Vs 19:59:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006749001 Vs 19:59:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006748028 +- 0.000002929 Vs 19:59:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006748028 +- 0.000002929 Vs BL = -0.08435035 +- 0.00003662 Tm 19:59:28 Position moved: 0.000000 m 19:59:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08435 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08435 0.00004 -0.08435 0.00000 19:59:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08435 0.00004 SL = -0.0843503 +- 0.0000366 Tm^2/m^n 19:59:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0843503 +- 0.0000366 Tm^2/m^n Remeasure 19:59:28 Magnetic Field Measurement Measuring the magnet strength... 19:59:28 Integrated Voltage Measurement... 19:59:29 Magnet Current for MAIN, Imag = 238.0272 A Vtrans = 2.380204 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:59:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006750997 Vs 19:59:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006753191 Vs 19:59:47 Magnet Current for MAIN, Imag = 238.0329 A Vtrans = 2.380261 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 19:59:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006751900 Vs 20:00:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006752364 Vs 20:00:03 Magnet Current for MAIN, Imag = 238.0309 A Vtrans = 2.380241 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:00:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006748254 Vs 20:00:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006751795 Vs 20:00:19 Magnet Current for MAIN, Imag = 238.0324 A Vtrans = 2.380256 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:00:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006757532 Vs 20:00:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006744295 Vs 20:00:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006751291 +- 0.000000880 Vs 20:00:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006751291 +- 0.000000880 Vs BL = -0.08439114 +- 0.00001100 Tm 20:00:39 Position moved: 0.000000 m 20:00:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.08439 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.08439 0.00001 -0.08439 0.00000 20:00:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.08439 0.00001 SL = -0.0843911 +- 0.0000110 Tm^2/m^n 20:00:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0843911 +- 0.0000110 Tm^2/m^n 20:00:42 Position moved: 0.000000 m 20:00:42 Magnet system MAIN current ramping to 224.0000 A... 20:00:57 Magnet Current for MAIN, Imag = 224.0906 A Vtrans = 2.240838 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:00:57 MAIN (V) Voltage Measurement, V = 8.685850 V 20:00:58 Temperature Measurement, Probe Number = 0, T = 30.781000 C 20:00:58 Temperature Measurement, Probe Number = 1, T = 30.586000 C 20:00:59 Temperature Measurement, Probe Number = 2, T = 28.521000 C 20:01:00 Temperature Measurement, Probe Number = 3, T = 31.121000 C 20:01:00 Temperature Measurement, Probe Number = 4, T = 27.896000 C 20:01:01 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007212 V 20:01:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007212 (V, A, ohm, ...), Measured Value = 0.540870 (C, atm, Hz, ...) 20:01:01 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002854 V 20:01:01 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002854 (V, A, ohm, ...), Measured Value = 0.214013 (C, atm, Hz, ...) 20:01:02 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003623 V 20:01:02 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003623 (V, A, ohm, ...), Measured Value = -0.000615 (C, atm, Hz, ...) 20:01:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 224.09 P1 = MAIN (V), Value = 8.69 P2 = Yoke, Value = 30.78 P3 = Coil, Value = 30.59 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 31.12 P6 = Ambient, Value = 27.90 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 20:01:02 Magnetic Field Measurement Measuring the magnet strength... 20:01:02 Integrated Voltage Measurement... 20:01:03 Magnet Current for MAIN, Imag = 224.0939 A Vtrans = 2.240871 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:01:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006380169 Vs 20:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006357609 Vs 20:01:20 Magnet Current for MAIN, Imag = 224.0984 A Vtrans = 2.240916 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:01:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006374013 Vs 20:01:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006357508 Vs 20:01:37 Magnet Current for MAIN, Imag = 224.1072 A Vtrans = 2.241004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:01:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006395906 Vs 20:01:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006360573 Vs 20:01:53 Magnet Current for MAIN, Imag = 224.0905 A Vtrans = 2.240837 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:02:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006365325 Vs 20:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006360447 Vs 20:02:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006368944 +- 0.000005771 Vs 20:02:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006368944 +- 0.000005771 Vs BL = -0.07961180 +- 0.00007214 Tm 20:02:13 Position moved: 0.000000 m 20:02:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07961 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07961 0.00007 -0.07961 0.00000 20:02:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07961 0.00007 SL = -0.0796118 +- 0.0000721 Tm^2/m^n 20:02:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0796118 +- 0.0000721 Tm^2/m^n Remeasure 20:02:13 Magnetic Field Measurement Measuring the magnet strength... 20:02:13 Integrated Voltage Measurement... 20:02:14 Magnet Current for MAIN, Imag = 224.0915 A Vtrans = 2.240847 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:02:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006358579 Vs 20:02:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006359188 Vs 20:02:32 Magnet Current for MAIN, Imag = 224.0939 A Vtrans = 2.240871 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:02:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006364686 Vs 20:02:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006356230 Vs 20:02:49 Magnet Current for MAIN, Imag = 224.0766 A Vtrans = 2.240698 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:02:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006367117 Vs 20:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006361098 Vs 20:03:05 Magnet Current for MAIN, Imag = 224.0886 A Vtrans = 2.240818 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:03:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006364016 Vs 20:03:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006365620 Vs 20:03:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006362067 +- 0.000002472 Vs 20:03:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006362067 +- 0.000002472 Vs BL = -0.07952584 +- 0.00003090 Tm 20:03:25 Position moved: 0.000000 m 20:03:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07953 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07953 0.00003 -0.07953 0.00000 20:03:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07953 0.00003 SL = -0.0795258 +- 0.0000309 Tm^2/m^n 20:03:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0795258 +- 0.0000309 Tm^2/m^n Remeasure 20:03:25 Magnetic Field Measurement Measuring the magnet strength... 20:03:25 Integrated Voltage Measurement... 20:03:26 Magnet Current for MAIN, Imag = 224.1068 A Vtrans = 2.241000 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:03:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006363609 Vs 20:03:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006361111 Vs 20:03:44 Magnet Current for MAIN, Imag = 224.0961 A Vtrans = 2.240893 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:03:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006357778 Vs 20:03:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006360591 Vs 20:04:00 Magnet Current for MAIN, Imag = 224.1595 A Vtrans = 2.241527 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006363005 Vs 20:04:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006361931 Vs 20:04:16 Magnet Current for MAIN, Imag = 224.1047 A Vtrans = 2.240979 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:04:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006361765 Vs 20:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.006365523 Vs 20:04:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.006361914 +- 0.000001654 Vs 20:04:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.006361914 +- 0.000001654 Vs BL = -0.07952393 +- 0.00002068 Tm 20:04:36 Position moved: 0.000000 m 20:04:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07952 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07952 0.00002 -0.07952 0.00000 20:04:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07952 0.00002 SL = -0.0795239 +- 0.0000207 Tm^2/m^n 20:04:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0795239 +- 0.0000207 Tm^2/m^n 20:04:39 Position moved: 0.000000 m 20:04:39 Magnet system MAIN current ramping to 210.0000 A... 20:04:53 Magnet Current for MAIN, Imag = 209.9889 A Vtrans = 2.099820 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:04:54 MAIN (V) Voltage Measurement, V = 8.143781 V 20:04:55 Temperature Measurement, Probe Number = 0, T = 30.758000 C 20:04:55 Temperature Measurement, Probe Number = 1, T = 30.384000 C 20:04:56 Temperature Measurement, Probe Number = 2, T = 28.517000 C 20:04:56 Temperature Measurement, Probe Number = 3, T = 30.870000 C 20:04:57 Temperature Measurement, Probe Number = 4, T = 27.839000 C 20:04:58 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007108 V 20:04:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007108 (V, A, ohm, ...), Measured Value = 0.533123 (C, atm, Hz, ...) 20:04:58 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002754 V 20:04:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002754 (V, A, ohm, ...), Measured Value = 0.206550 (C, atm, Hz, ...) 20:04:59 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003921 V 20:04:59 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003921 (V, A, ohm, ...), Measured Value = -0.000666 (C, atm, Hz, ...) 20:04:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 209.99 P1 = MAIN (V), Value = 8.14 P2 = Yoke, Value = 30.76 P3 = Coil, Value = 30.38 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 30.87 P6 = Ambient, Value = 27.84 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 20:04:59 Magnetic Field Measurement Measuring the magnet strength... 20:04:59 Integrated Voltage Measurement... 20:05:00 Magnet Current for MAIN, Imag = 209.9952 A Vtrans = 2.099884 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:05:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005971667 Vs 20:05:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005970712 Vs 20:05:18 Magnet Current for MAIN, Imag = 209.9807 A Vtrans = 2.099739 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:05:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005968321 Vs 20:05:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005973453 Vs 20:05:34 Magnet Current for MAIN, Imag = 209.9877 A Vtrans = 2.099809 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:05:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005970446 Vs 20:05:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005965988 Vs 20:05:51 Magnet Current for MAIN, Imag = 209.9803 A Vtrans = 2.099735 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:05:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005979845 Vs 20:06:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005968449 Vs 20:06:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005971110 +- 0.000002100 Vs 20:06:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005971110 +- 0.000002100 Vs BL = -0.07463888 +- 0.00002626 Tm 20:06:11 Position moved: 0.000000 m 20:06:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07464 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07464 0.00003 -0.07464 0.00000 20:06:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07464 0.00003 SL = -0.0746389 +- 0.0000263 Tm^2/m^n 20:06:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0746389 +- 0.0000263 Tm^2/m^n Remeasure 20:06:11 Magnetic Field Measurement Measuring the magnet strength... 20:06:11 Integrated Voltage Measurement... 20:06:12 Magnet Current for MAIN, Imag = 210.0330 A Vtrans = 2.100262 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:06:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005982986 Vs 20:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005962745 Vs 20:06:29 Magnet Current for MAIN, Imag = 209.9881 A Vtrans = 2.099813 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005962635 Vs 20:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005963275 Vs 20:06:46 Magnet Current for MAIN, Imag = 209.9855 A Vtrans = 2.099787 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:06:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005960963 Vs 20:07:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005964852 Vs 20:07:03 Magnet Current for MAIN, Imag = 209.9918 A Vtrans = 2.099850 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:07:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005962093 Vs 20:07:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005963428 Vs 20:07:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005965372 +- 0.000004327 Vs 20:07:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005965372 +- 0.000004327 Vs BL = -0.07456715 +- 0.00005409 Tm 20:07:23 Position moved: 0.000000 m 20:07:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07457 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07457 0.00005 -0.07457 0.00000 20:07:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07457 0.00005 SL = -0.0745672 +- 0.0000541 Tm^2/m^n 20:07:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0745672 +- 0.0000541 Tm^2/m^n Remeasure 20:07:23 Magnetic Field Measurement Measuring the magnet strength... 20:07:23 Integrated Voltage Measurement... 20:07:23 Magnet Current for MAIN, Imag = 209.9824 A Vtrans = 2.099756 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:07:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005949347 Vs 20:07:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005964890 Vs 20:07:41 Magnet Current for MAIN, Imag = 210.0431 A Vtrans = 2.100363 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:07:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005977723 Vs 20:07:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005967470 Vs 20:07:58 Magnet Current for MAIN, Imag = 209.9916 A Vtrans = 2.099848 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:08:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005968429 Vs 20:08:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005961937 Vs 20:08:15 Magnet Current for MAIN, Imag = 209.9896 A Vtrans = 2.099828 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005966539 Vs 20:08:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005964358 Vs 20:08:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005965087 +- 0.000005478 Vs 20:08:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005965087 +- 0.000005478 Vs BL = -0.07456358 +- 0.00006848 Tm 20:08:34 Position moved: 0.000000 m 20:08:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07456 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07456 0.00007 -0.07456 0.00000 20:08:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07456 0.00007 SL = -0.0745636 +- 0.0000685 Tm^2/m^n 20:08:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0745636 +- 0.0000685 Tm^2/m^n 20:08:37 Position moved: 0.000000 m 20:08:37 Magnet system MAIN current ramping to 196.0000 A... 20:08:52 Magnet Current for MAIN, Imag = 196.0356 A Vtrans = 1.960288 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:08:53 MAIN (V) Voltage Measurement, V = 7.611521 V 20:08:54 Temperature Measurement, Probe Number = 0, T = 30.700000 C 20:08:54 Temperature Measurement, Probe Number = 1, T = 30.220000 C 20:08:55 Temperature Measurement, Probe Number = 2, T = 28.510000 C 20:08:55 Temperature Measurement, Probe Number = 3, T = 30.585000 C 20:08:56 Temperature Measurement, Probe Number = 4, T = 27.778000 C 20:08:57 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007142 V 20:08:57 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007142 (V, A, ohm, ...), Measured Value = 0.535642 (C, atm, Hz, ...) 20:08:57 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002807 V 20:08:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002807 (V, A, ohm, ...), Measured Value = 0.210525 (C, atm, Hz, ...) 20:08:58 Sensor Voltage Measurement, Sensor Number = 2, V = -0.014401 V 20:08:58 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.014401 (V, A, ohm, ...), Measured Value = -0.002446 (C, atm, Hz, ...) 20:08:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 196.04 P1 = MAIN (V), Value = 7.61 P2 = Yoke, Value = 30.70 P3 = Coil, Value = 30.22 P4 = H20_In, Value = 28.51 P5 = H2O_Out, Value = 30.59 P6 = Ambient, Value = 27.78 P7 = Supply Pres(psi), Value = 0.54 P8 = Return Pres(psi), Value = 0.21 P9 = Flow Rate(gpm), Value = -0.00 20:08:58 Magnetic Field Measurement Measuring the magnet strength... 20:08:59 Integrated Voltage Measurement... 20:08:59 Magnet Current for MAIN, Imag = 196.0317 A Vtrans = 1.960249 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:09:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005584631 Vs 20:09:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005573889 Vs 20:09:17 Magnet Current for MAIN, Imag = 196.0417 A Vtrans = 1.960349 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:09:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005577214 Vs 20:09:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005575743 Vs 20:09:34 Magnet Current for MAIN, Imag = 196.0737 A Vtrans = 1.960669 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:09:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005575599 Vs 20:09:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005575618 Vs 20:09:50 Magnet Current for MAIN, Imag = 196.0299 A Vtrans = 1.960231 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:09:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005586760 Vs 20:10:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005576875 Vs 20:10:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005578291 +- 0.000002442 Vs 20:10:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005578291 +- 0.000002442 Vs BL = -0.06972864 +- 0.00003053 Tm 20:10:10 Position moved: 0.000000 m 20:10:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06973 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06973 0.00003 -0.06973 0.00000 20:10:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06973 0.00003 SL = -0.0697286 +- 0.0000305 Tm^2/m^n 20:10:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0697286 +- 0.0000305 Tm^2/m^n Remeasure 20:10:10 Magnetic Field Measurement Measuring the magnet strength... 20:10:10 Integrated Voltage Measurement... 20:10:11 Magnet Current for MAIN, Imag = 196.0174 A Vtrans = 1.960106 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:10:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005582286 Vs 20:10:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005576728 Vs 20:10:28 Magnet Current for MAIN, Imag = 196.0153 A Vtrans = 1.960085 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:10:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005574326 Vs 20:10:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005573796 Vs 20:10:44 Magnet Current for MAIN, Imag = 196.0191 A Vtrans = 1.960123 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:10:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005567429 Vs 20:11:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005581147 Vs 20:11:01 Magnet Current for MAIN, Imag = 196.0347 A Vtrans = 1.960279 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:11:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005572612 Vs 20:11:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005570007 Vs 20:11:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005574791 +- 0.000002964 Vs 20:11:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005574791 +- 0.000002964 Vs BL = -0.06968489 +- 0.00003705 Tm 20:11:20 Position moved: 0.000000 m 20:11:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06968 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06968 0.00004 -0.06968 0.00000 20:11:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06968 0.00004 SL = -0.0696849 +- 0.0000371 Tm^2/m^n 20:11:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0696849 +- 0.0000371 Tm^2/m^n Remeasure 20:11:21 Magnetic Field Measurement Measuring the magnet strength... 20:11:21 Integrated Voltage Measurement... 20:11:21 Magnet Current for MAIN, Imag = 196.0010 A Vtrans = 1.959942 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:11:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005599920 Vs 20:11:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005577723 Vs 20:11:39 Magnet Current for MAIN, Imag = 196.0257 A Vtrans = 1.960189 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:11:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005554448 Vs 20:11:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005580617 Vs 20:11:56 Magnet Current for MAIN, Imag = 196.0356 A Vtrans = 1.960288 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:12:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005584838 Vs 20:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005578120 Vs 20:12:12 Magnet Current for MAIN, Imag = 196.0355 A Vtrans = 1.960287 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005576179 Vs 20:12:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005575922 Vs 20:12:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005578471 +- 0.000007773 Vs 20:12:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005578471 +- 0.000007773 Vs BL = -0.06973089 +- 0.00009716 Tm 20:12:32 Position moved: 0.000000 m 20:12:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06973 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06973 0.00010 -0.06973 0.00000 20:12:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06973 0.00010 SL = -0.0697309 +- 0.0000972 Tm^2/m^n 20:12:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0697309 +- 0.0000972 Tm^2/m^n 20:12:35 Position moved: 0.000000 m 20:12:35 Magnet system MAIN current ramping to 182.0000 A... 20:12:50 Magnet Current for MAIN, Imag = 181.9154 A Vtrans = 1.819086 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:12:50 MAIN (V) Voltage Measurement, V = 7.067356 V 20:12:51 Temperature Measurement, Probe Number = 0, T = 30.626000 C 20:12:52 Temperature Measurement, Probe Number = 1, T = 30.050000 C 20:12:52 Temperature Measurement, Probe Number = 2, T = 28.515000 C 20:12:53 Temperature Measurement, Probe Number = 3, T = 30.304000 C 20:12:53 Temperature Measurement, Probe Number = 4, T = 27.760000 C 20:12:54 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006953 V 20:12:54 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006953 (V, A, ohm, ...), Measured Value = 0.521497 (C, atm, Hz, ...) 20:12:55 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002668 V 20:12:55 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002668 (V, A, ohm, ...), Measured Value = 0.200063 (C, atm, Hz, ...) 20:12:55 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001812 V 20:12:55 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001812 (V, A, ohm, ...), Measured Value = -0.000308 (C, atm, Hz, ...) 20:12:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 181.92 P1 = MAIN (V), Value = 7.07 P2 = Yoke, Value = 30.63 P3 = Coil, Value = 30.05 P4 = H20_In, Value = 28.52 P5 = H2O_Out, Value = 30.30 P6 = Ambient, Value = 27.76 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 20:12:56 Magnetic Field Measurement Measuring the magnet strength... 20:12:56 Integrated Voltage Measurement... 20:12:56 Magnet Current for MAIN, Imag = 181.9327 A Vtrans = 1.819259 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:13:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005179865 Vs 20:13:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005178602 Vs 20:13:14 Magnet Current for MAIN, Imag = 181.9385 A Vtrans = 1.819317 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:13:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005179455 Vs 20:13:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005179472 Vs 20:13:30 Magnet Current for MAIN, Imag = 181.9226 A Vtrans = 1.819158 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:13:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005197995 Vs 20:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005180307 Vs 20:13:47 Magnet Current for MAIN, Imag = 181.9302 A Vtrans = 1.819234 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:13:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005178578 Vs 20:14:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005179909 Vs 20:14:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005181773 +- 0.000004261 Vs 20:14:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005181773 +- 0.000004261 Vs BL = -0.06477216 +- 0.00005326 Tm 20:14:06 Position moved: 0.000000 m 20:14:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06477 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06477 0.00005 -0.06477 0.00000 20:14:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06477 0.00005 SL = -0.0647722 +- 0.0000533 Tm^2/m^n 20:14:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0647722 +- 0.0000533 Tm^2/m^n Remeasure 20:14:07 Magnetic Field Measurement Measuring the magnet strength... 20:14:07 Integrated Voltage Measurement... 20:14:07 Magnet Current for MAIN, Imag = 181.9175 A Vtrans = 1.819106 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:14:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005189821 Vs 20:14:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005178687 Vs 20:14:25 Magnet Current for MAIN, Imag = 181.9336 A Vtrans = 1.819268 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:14:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005204373 Vs 20:14:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005177967 Vs 20:14:41 Magnet Current for MAIN, Imag = 181.9534 A Vtrans = 1.819466 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:14:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005169200 Vs 20:14:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005179489 Vs 20:14:58 Magnet Current for MAIN, Imag = 181.9699 A Vtrans = 1.819631 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:15:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005177340 Vs 20:15:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005178044 Vs 20:15:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005181865 +- 0.000006447 Vs 20:15:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005181865 +- 0.000006447 Vs BL = -0.06477332 +- 0.00008059 Tm 20:15:18 Position moved: 0.000000 m 20:15:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06477 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06477 0.00008 -0.06477 0.00000 20:15:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06477 0.00008 SL = -0.0647733 +- 0.0000806 Tm^2/m^n 20:15:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0647733 +- 0.0000806 Tm^2/m^n Remeasure 20:15:18 Magnetic Field Measurement Measuring the magnet strength... 20:15:18 Integrated Voltage Measurement... 20:15:19 Magnet Current for MAIN, Imag = 181.9066 A Vtrans = 1.818998 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:15:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005178936 Vs 20:15:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005176017 Vs 20:15:36 Magnet Current for MAIN, Imag = 181.9342 A Vtrans = 1.819274 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:15:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005178003 Vs 20:15:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005176343 Vs 20:15:53 Magnet Current for MAIN, Imag = 181.9455 A Vtrans = 1.819387 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:16:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005160515 Vs 20:16:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005171475 Vs 20:16:10 Magnet Current for MAIN, Imag = 181.9618 A Vtrans = 1.819549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005170993 Vs 20:16:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.005180598 Vs 20:16:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.005174110 +- 0.000004728 Vs 20:16:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.005174110 +- 0.000004728 Vs BL = -0.06467637 +- 0.00005910 Tm 20:16:30 Position moved: 0.000000 m 20:16:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06468 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06468 0.00006 -0.06468 0.00000 20:16:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06468 0.00006 SL = -0.0646764 +- 0.0000591 Tm^2/m^n 20:16:30 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0646764 +- 0.0000591 Tm^2/m^n 20:16:33 Position moved: 0.000000 m 20:16:33 Magnet system MAIN current ramping to 168.0000 A... 20:16:48 Magnet Current for MAIN, Imag = 168.0411 A Vtrans = 1.680343 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:16:48 MAIN (V) Voltage Measurement, V = 6.534108 V 20:16:49 Temperature Measurement, Probe Number = 0, T = 30.589000 C 20:16:50 Temperature Measurement, Probe Number = 1, T = 29.895000 C 20:16:50 Temperature Measurement, Probe Number = 2, T = 28.476000 C 20:16:51 Temperature Measurement, Probe Number = 3, T = 30.049000 C 20:16:52 Temperature Measurement, Probe Number = 4, T = 27.670000 C 20:16:52 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007018 V 20:16:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007018 (V, A, ohm, ...), Measured Value = 0.526342 (C, atm, Hz, ...) 20:16:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002500 V 20:16:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002500 (V, A, ohm, ...), Measured Value = 0.187463 (C, atm, Hz, ...) 20:16:54 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002903 V 20:16:54 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002903 (V, A, ohm, ...), Measured Value = -0.000493 (C, atm, Hz, ...) 20:16:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 168.04 P1 = MAIN (V), Value = 6.53 P2 = Yoke, Value = 30.59 P3 = Coil, Value = 29.89 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 30.05 P6 = Ambient, Value = 27.67 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 20:16:54 Magnetic Field Measurement Measuring the magnet strength... 20:16:54 Integrated Voltage Measurement... 20:16:55 Magnet Current for MAIN, Imag = 167.9691 A Vtrans = 1.679623 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:17:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004781807 Vs 20:17:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004784859 Vs 20:17:13 Magnet Current for MAIN, Imag = 167.9991 A Vtrans = 1.679923 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:17:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004780476 Vs 20:17:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004790503 Vs 20:17:30 Magnet Current for MAIN, Imag = 167.9907 A Vtrans = 1.679839 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:17:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004801161 Vs 20:17:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004781264 Vs 20:17:47 Magnet Current for MAIN, Imag = 167.9833 A Vtrans = 1.679765 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:17:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004774242 Vs 20:18:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004782565 Vs 20:18:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004784610 +- 0.000004596 Vs 20:18:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004784610 +- 0.000004596 Vs BL = -0.05980762 +- 0.00005746 Tm 20:18:06 Position moved: 0.000000 m 20:18:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05981 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05981 0.00006 -0.05981 0.00000 20:18:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05981 0.00006 SL = -0.0598076 +- 0.0000575 Tm^2/m^n 20:18:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0598076 +- 0.0000575 Tm^2/m^n Remeasure 20:18:06 Magnetic Field Measurement Measuring the magnet strength... 20:18:06 Integrated Voltage Measurement... 20:18:07 Magnet Current for MAIN, Imag = 167.9923 A Vtrans = 1.679855 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:18:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004794968 Vs 20:18:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004787324 Vs 20:18:25 Magnet Current for MAIN, Imag = 167.9845 A Vtrans = 1.679777 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:18:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004816443 Vs 20:18:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004786313 Vs 20:18:41 Magnet Current for MAIN, Imag = 167.9954 A Vtrans = 1.679885 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:18:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004813658 Vs 20:18:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004780692 Vs 20:18:58 Magnet Current for MAIN, Imag = 167.9832 A Vtrans = 1.679764 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:19:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004815671 Vs 20:19:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004784611 Vs 20:19:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004797460 +- 0.000003952 Vs 20:19:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004797460 +- 0.000003952 Vs BL = -0.05996825 +- 0.00004941 Tm 20:19:18 Position moved: 0.000000 m 20:19:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05997 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05997 0.00005 -0.05997 0.00000 20:19:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05997 0.00005 SL = -0.0599683 +- 0.0000494 Tm^2/m^n 20:19:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0599683 +- 0.0000494 Tm^2/m^n Remeasure 20:19:18 Magnetic Field Measurement Measuring the magnet strength... 20:19:18 Integrated Voltage Measurement... 20:19:19 Magnet Current for MAIN, Imag = 167.9694 A Vtrans = 1.679626 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:19:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004788585 Vs 20:19:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004787873 Vs 20:19:36 Magnet Current for MAIN, Imag = 167.9942 A Vtrans = 1.679874 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:19:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004756747 Vs 20:19:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004787456 Vs 20:19:53 Magnet Current for MAIN, Imag = 167.9859 A Vtrans = 1.679791 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:20:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004796344 Vs 20:20:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004785086 Vs 20:20:09 Magnet Current for MAIN, Imag = 167.9932 A Vtrans = 1.679863 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:20:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004804818 Vs 20:20:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004788001 Vs 20:20:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004786864 +- 0.000009024 Vs 20:20:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004786864 +- 0.000009024 Vs BL = -0.05983580 +- 0.00011280 Tm 20:20:29 Position moved: 0.000000 m 20:20:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05984 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05984 0.00011 -0.05984 0.00000 20:20:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05984 0.00011 SL = -0.0598358 +- 0.0001128 Tm^2/m^n 20:20:29 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0598358 +- 0.0001128 Tm^2/m^n 20:20:32 Position moved: 0.000000 m 20:20:32 Magnet system MAIN current ramping to 154.0000 A... 20:20:47 Magnet Current for MAIN, Imag = 154.0455 A Vtrans = 1.540387 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:20:48 MAIN (V) Voltage Measurement, V = 5.996850 V 20:20:48 Temperature Measurement, Probe Number = 0, T = 30.512000 C 20:20:49 Temperature Measurement, Probe Number = 1, T = 29.726000 C 20:20:50 Temperature Measurement, Probe Number = 2, T = 28.503000 C 20:20:50 Temperature Measurement, Probe Number = 3, T = 29.775000 C 20:20:51 Temperature Measurement, Probe Number = 4, T = 27.599000 C 20:20:52 Sensor Voltage Measurement, Sensor Number = 0, V = 1.007026 V 20:20:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.007026 (V, A, ohm, ...), Measured Value = 0.526920 (C, atm, Hz, ...) 20:20:52 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002453 V 20:20:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002453 (V, A, ohm, ...), Measured Value = 0.183975 (C, atm, Hz, ...) 20:20:53 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001408 V 20:20:53 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001408 (V, A, ohm, ...), Measured Value = -0.000239 (C, atm, Hz, ...) 20:20:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 154.05 P1 = MAIN (V), Value = 6.00 P2 = Yoke, Value = 30.51 P3 = Coil, Value = 29.73 P4 = H20_In, Value = 28.50 P5 = H2O_Out, Value = 29.77 P6 = Ambient, Value = 27.60 P7 = Supply Pres(psi), Value = 0.53 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 20:20:53 Magnetic Field Measurement Measuring the magnet strength... 20:20:53 Integrated Voltage Measurement... 20:20:54 Magnet Current for MAIN, Imag = 154.0471 A Vtrans = 1.540403 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:21:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004391355 Vs 20:21:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004398373 Vs 20:21:11 Magnet Current for MAIN, Imag = 154.0500 A Vtrans = 1.540432 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:21:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004395485 Vs 20:21:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004396789 Vs 20:21:28 Magnet Current for MAIN, Imag = 154.0617 A Vtrans = 1.540549 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:21:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004369196 Vs 20:21:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004393500 Vs 20:21:45 Magnet Current for MAIN, Imag = 154.0499 A Vtrans = 1.540431 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:21:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004417422 Vs 20:22:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004394040 Vs 20:22:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004394520 +- 0.000008688 Vs 20:22:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004394520 +- 0.000008688 Vs BL = -0.05493150 +- 0.00010860 Tm 20:22:04 Position moved: 0.000000 m 20:22:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05493 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05493 0.00011 -0.05493 0.00000 20:22:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05493 0.00011 SL = -0.0549315 +- 0.0001086 Tm^2/m^n 20:22:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0549315 +- 0.0001086 Tm^2/m^n Remeasure 20:22:04 Magnetic Field Measurement Measuring the magnet strength... 20:22:04 Integrated Voltage Measurement... 20:22:05 Magnet Current for MAIN, Imag = 154.0478 A Vtrans = 1.540410 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:22:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004404433 Vs 20:22:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004393442 Vs 20:22:23 Magnet Current for MAIN, Imag = 154.0511 A Vtrans = 1.540443 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:22:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004360711 Vs 20:22:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004394332 Vs 20:22:39 Magnet Current for MAIN, Imag = 154.0446 A Vtrans = 1.540378 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:22:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004393420 Vs 20:22:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004393493 Vs 20:22:55 Magnet Current for MAIN, Imag = 154.0400 A Vtrans = 1.540332 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004398784 Vs 20:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004391516 Vs 20:23:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004391266 +- 0.000008180 Vs 20:23:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004391266 +- 0.000008180 Vs BL = -0.05489083 +- 0.00010225 Tm 20:23:15 Position moved: 0.000000 m 20:23:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05489 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05489 0.00010 -0.05489 0.00000 20:23:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05489 0.00010 SL = -0.0548908 +- 0.0001023 Tm^2/m^n 20:23:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0548908 +- 0.0001023 Tm^2/m^n Remeasure 20:23:15 Magnetic Field Measurement Measuring the magnet strength... 20:23:15 Integrated Voltage Measurement... 20:23:15 Magnet Current for MAIN, Imag = 154.0378 A Vtrans = 1.540310 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:23:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004377163 Vs 20:23:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004389274 Vs 20:23:33 Magnet Current for MAIN, Imag = 154.0397 A Vtrans = 1.540328 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:23:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004407502 Vs 20:23:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004392457 Vs 20:23:49 Magnet Current for MAIN, Imag = 154.0438 A Vtrans = 1.540370 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:23:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004407388 Vs 20:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004390419 Vs 20:24:06 Magnet Current for MAIN, Imag = 154.0493 A Vtrans = 1.540425 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:24:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004404387 Vs 20:24:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004390316 Vs 20:24:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004394863 +- 0.000006788 Vs 20:24:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004394863 +- 0.000006788 Vs BL = -0.05493579 +- 0.00008485 Tm 20:24:25 Position moved: 0.000000 m 20:24:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05494 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05494 0.00008 -0.05494 0.00000 20:24:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05494 0.00008 SL = -0.0549358 +- 0.0000848 Tm^2/m^n 20:24:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0549358 +- 0.0000848 Tm^2/m^n 20:24:28 Position moved: 0.000000 m 20:24:28 Magnet system MAIN current ramping to 140.0000 A... 20:24:43 Magnet Current for MAIN, Imag = 139.9199 A Vtrans = 1.399131 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:24:43 MAIN (V) Voltage Measurement, V = 5.468541 V 20:24:44 Temperature Measurement, Probe Number = 0, T = 30.457000 C 20:24:45 Temperature Measurement, Probe Number = 1, T = 29.553000 C 20:24:45 Temperature Measurement, Probe Number = 2, T = 28.487000 C 20:24:46 Temperature Measurement, Probe Number = 3, T = 29.543000 C 20:24:46 Temperature Measurement, Probe Number = 4, T = 27.544000 C 20:24:47 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006909 V 20:24:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006909 (V, A, ohm, ...), Measured Value = 0.518205 (C, atm, Hz, ...) 20:24:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002498 V 20:24:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002498 (V, A, ohm, ...), Measured Value = 0.187365 (C, atm, Hz, ...) 20:24:48 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003479 V 20:24:48 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003479 (V, A, ohm, ...), Measured Value = -0.000591 (C, atm, Hz, ...) 20:24:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 139.92 P1 = MAIN (V), Value = 5.47 P2 = Yoke, Value = 30.46 P3 = Coil, Value = 29.55 P4 = H20_In, Value = 28.49 P5 = H2O_Out, Value = 29.54 P6 = Ambient, Value = 27.54 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.19 P9 = Flow Rate(gpm), Value = -0.00 20:24:48 Magnetic Field Measurement Measuring the magnet strength... 20:24:48 Integrated Voltage Measurement... 20:24:49 Magnet Current for MAIN, Imag = 139.9177 A Vtrans = 1.399109 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:24:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004016541 Vs 20:25:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003992892 Vs 20:25:07 Magnet Current for MAIN, Imag = 139.9161 A Vtrans = 1.399093 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:25:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004002351 Vs 20:25:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003990355 Vs 20:25:23 Magnet Current for MAIN, Imag = 139.9194 A Vtrans = 1.399126 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:25:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003993814 Vs 20:25:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003986111 Vs 20:25:40 Magnet Current for MAIN, Imag = 139.9194 A Vtrans = 1.399126 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:25:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003977487 Vs 20:25:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003989813 Vs 20:25:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003993671 +- 0.000007800 Vs 20:25:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003993671 +- 0.000007800 Vs BL = -0.04992088 +- 0.00009750 Tm 20:25:59 Position moved: 0.000000 m 20:25:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04992 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04992 0.00010 -0.04992 0.00000 20:25:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04992 0.00010 SL = -0.0499209 +- 0.0000975 Tm^2/m^n 20:25:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0499209 +- 0.0000975 Tm^2/m^n Remeasure 20:26:00 Magnetic Field Measurement Measuring the magnet strength... 20:26:00 Integrated Voltage Measurement... 20:26:00 Magnet Current for MAIN, Imag = 139.9150 A Vtrans = 1.399082 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:26:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004009467 Vs 20:26:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003992296 Vs 20:26:18 Magnet Current for MAIN, Imag = 139.9188 A Vtrans = 1.399120 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:26:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003976299 Vs 20:26:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003995328 Vs 20:26:34 Magnet Current for MAIN, Imag = 139.9210 A Vtrans = 1.399142 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:26:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004005500 Vs 20:26:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003991330 Vs 20:26:51 Magnet Current for MAIN, Imag = 139.9185 A Vtrans = 1.399117 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:26:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004016134 Vs 20:27:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003986461 Vs 20:27:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003996602 +- 0.000006325 Vs 20:27:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003996602 +- 0.000006325 Vs BL = -0.04995753 +- 0.00007907 Tm 20:27:10 Position moved: 0.000000 m 20:27:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04996 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04996 0.00008 -0.04996 0.00000 20:27:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04996 0.00008 SL = -0.0499575 +- 0.0000791 Tm^2/m^n 20:27:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0499575 +- 0.0000791 Tm^2/m^n Remeasure 20:27:10 Magnetic Field Measurement Measuring the magnet strength... 20:27:10 Integrated Voltage Measurement... 20:27:11 Magnet Current for MAIN, Imag = 139.9135 A Vtrans = 1.399067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:27:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004005511 Vs 20:27:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003993962 Vs 20:27:28 Magnet Current for MAIN, Imag = 139.9167 A Vtrans = 1.399099 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:27:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004022626 Vs 20:27:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.004002649 Vs 20:27:44 Magnet Current for MAIN, Imag = 139.9086 A Vtrans = 1.399018 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:27:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003999033 Vs 20:28:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003995387 Vs 20:28:01 Magnet Current for MAIN, Imag = 139.9075 A Vtrans = 1.399007 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003993159 Vs 20:28:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003998792 Vs 20:28:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.004001390 +- 0.000006634 Vs 20:28:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.004001390 +- 0.000006634 Vs BL = -0.05001737 +- 0.00008292 Tm 20:28:21 Position moved: 0.000000 m 20:28:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05002 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05002 0.00008 -0.05002 0.00000 20:28:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05002 0.00008 SL = -0.0500174 +- 0.0000829 Tm^2/m^n 20:28:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0500174 +- 0.0000829 Tm^2/m^n 20:28:24 Position moved: 0.000000 m 20:28:24 Magnet system MAIN current ramping to 126.0000 A... 20:28:39 Magnet Current for MAIN, Imag = 125.9697 A Vtrans = 1.259629 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:28:39 MAIN (V) Voltage Measurement, V = 4.928761 V 20:28:40 Temperature Measurement, Probe Number = 0, T = 30.390000 C 20:28:41 Temperature Measurement, Probe Number = 1, T = 29.446000 C 20:28:41 Temperature Measurement, Probe Number = 2, T = 28.480000 C 20:28:42 Temperature Measurement, Probe Number = 3, T = 29.328000 C 20:28:42 Temperature Measurement, Probe Number = 4, T = 27.469000 C 20:28:43 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006961 V 20:28:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006961 (V, A, ohm, ...), Measured Value = 0.522075 (C, atm, Hz, ...) 20:28:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002634 V 20:28:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002634 (V, A, ohm, ...), Measured Value = 0.197542 (C, atm, Hz, ...) 20:28:44 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000237 V 20:28:44 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000237 (V, A, ohm, ...), Measured Value = -0.000040 (C, atm, Hz, ...) 20:28:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 125.97 P1 = MAIN (V), Value = 4.93 P2 = Yoke, Value = 30.39 P3 = Coil, Value = 29.45 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 29.33 P6 = Ambient, Value = 27.47 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.20 P9 = Flow Rate(gpm), Value = -0.00 20:28:44 Magnetic Field Measurement Measuring the magnet strength... 20:28:45 Integrated Voltage Measurement... 20:28:45 Magnet Current for MAIN, Imag = 125.9712 A Vtrans = 1.259644 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:28:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003597127 Vs 20:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003601642 Vs 20:29:03 Magnet Current for MAIN, Imag = 125.9690 A Vtrans = 1.259622 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:29:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003602665 Vs 20:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003595999 Vs 20:29:19 Magnet Current for MAIN, Imag = 125.9701 A Vtrans = 1.259633 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003599250 Vs 20:29:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003604008 Vs 20:29:36 Magnet Current for MAIN, Imag = 125.9705 A Vtrans = 1.259637 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:29:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003610729 Vs 20:29:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003601485 Vs 20:29:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003601613 +- 0.000002755 Vs 20:29:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003601613 +- 0.000002755 Vs BL = -0.04502016 +- 0.00003444 Tm 20:29:55 Position moved: 0.000000 m 20:29:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04502 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04502 0.00003 -0.04502 0.00000 20:29:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04502 0.00003 SL = -0.0450202 +- 0.0000344 Tm^2/m^n 20:29:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0450202 +- 0.0000344 Tm^2/m^n Remeasure 20:29:56 Magnetic Field Measurement Measuring the magnet strength... 20:29:56 Integrated Voltage Measurement... 20:29:57 Magnet Current for MAIN, Imag = 125.9688 A Vtrans = 1.259620 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:30:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003616379 Vs 20:30:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003595452 Vs 20:30:15 Magnet Current for MAIN, Imag = 125.9711 A Vtrans = 1.259643 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:30:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003626303 Vs 20:30:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003609137 Vs 20:30:31 Magnet Current for MAIN, Imag = 125.9696 A Vtrans = 1.259627 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:30:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003618916 Vs 20:30:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003599579 Vs 20:30:48 Magnet Current for MAIN, Imag = 125.9684 A Vtrans = 1.259616 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003629660 Vs 20:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003598910 Vs 20:31:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003611792 +- 0.000004538 Vs 20:31:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003611792 +- 0.000004538 Vs BL = -0.04514740 +- 0.00005672 Tm 20:31:08 Position moved: 0.000000 m 20:31:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04515 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04515 0.00006 -0.04515 0.00000 20:31:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04515 0.00006 SL = -0.0451474 +- 0.0000567 Tm^2/m^n 20:31:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0451474 +- 0.0000567 Tm^2/m^n Remeasure 20:31:08 Magnetic Field Measurement Measuring the magnet strength... 20:31:08 Integrated Voltage Measurement... 20:31:09 Magnet Current for MAIN, Imag = 125.9694 A Vtrans = 1.259626 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:31:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003611073 Vs 20:31:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003601007 Vs 20:31:27 Magnet Current for MAIN, Imag = 125.9676 A Vtrans = 1.259608 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:31:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003585081 Vs 20:31:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003600058 Vs 20:31:43 Magnet Current for MAIN, Imag = 125.9706 A Vtrans = 1.259638 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:31:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003624379 Vs 20:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003599431 Vs 20:32:00 Magnet Current for MAIN, Imag = 125.9674 A Vtrans = 1.259605 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:32:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003608267 Vs 20:32:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003597517 Vs 20:32:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003603352 +- 0.000007015 Vs 20:32:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003603352 +- 0.000007015 Vs BL = -0.04504190 +- 0.00008769 Tm 20:32:20 Position moved: 0.000000 m 20:32:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04504 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04504 0.00009 -0.04504 0.00000 20:32:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04504 0.00009 SL = -0.0450419 +- 0.0000877 Tm^2/m^n 20:32:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0450419 +- 0.0000877 Tm^2/m^n 20:32:23 Position moved: 0.000000 m 20:32:23 Magnet system MAIN current ramping to 112.0000 A... 20:32:38 Magnet Current for MAIN, Imag = 112.0144 A Vtrans = 1.120076 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:32:38 MAIN (V) Voltage Measurement, V = 4.379855 V 20:32:39 Temperature Measurement, Probe Number = 0, T = 30.314000 C 20:32:39 Temperature Measurement, Probe Number = 1, T = 29.331000 C 20:32:40 Temperature Measurement, Probe Number = 2, T = 28.476000 C 20:32:41 Temperature Measurement, Probe Number = 3, T = 29.116000 C 20:32:41 Temperature Measurement, Probe Number = 4, T = 27.409000 C 20:32:42 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006917 V 20:32:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006917 (V, A, ohm, ...), Measured Value = 0.518782 (C, atm, Hz, ...) 20:32:43 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002436 V 20:32:43 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002436 (V, A, ohm, ...), Measured Value = 0.182715 (C, atm, Hz, ...) 20:32:43 Sensor Voltage Measurement, Sensor Number = 2, V = -0.001127 V 20:32:43 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.001127 (V, A, ohm, ...), Measured Value = -0.000191 (C, atm, Hz, ...) 20:32:43 Magnet Test Parameter Measurements P0 = MAIN, Value = 112.01 P1 = MAIN (V), Value = 4.38 P2 = Yoke, Value = 30.31 P3 = Coil, Value = 29.33 P4 = H20_In, Value = 28.48 P5 = H2O_Out, Value = 29.12 P6 = Ambient, Value = 27.41 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 20:32:43 Magnetic Field Measurement Measuring the magnet strength... 20:32:43 Integrated Voltage Measurement... 20:32:44 Magnet Current for MAIN, Imag = 112.0144 A Vtrans = 1.120076 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:32:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003197781 Vs 20:33:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003202051 Vs 20:33:01 Magnet Current for MAIN, Imag = 112.0130 A Vtrans = 1.120062 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:33:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003202500 Vs 20:33:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003199536 Vs 20:33:18 Magnet Current for MAIN, Imag = 112.0143 A Vtrans = 1.120075 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:33:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003213910 Vs 20:33:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003193387 Vs 20:33:34 Magnet Current for MAIN, Imag = 112.0128 A Vtrans = 1.120060 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:33:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003199117 Vs 20:33:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003208876 Vs 20:33:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003202145 +- 0.000001727 Vs 20:33:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003202145 +- 0.000001727 Vs BL = -0.04002681 +- 0.00002158 Tm 20:33:53 Position moved: 0.000000 m 20:33:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04003 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04003 0.00002 -0.04003 0.00000 20:33:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04003 0.00002 SL = -0.0400268 +- 0.0000216 Tm^2/m^n 20:33:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0400268 +- 0.0000216 Tm^2/m^n Remeasure 20:33:53 Magnetic Field Measurement Measuring the magnet strength... 20:33:54 Integrated Voltage Measurement... 20:33:54 Magnet Current for MAIN, Imag = 112.0137 A Vtrans = 1.120069 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:34:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003214551 Vs 20:34:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003198393 Vs 20:34:12 Magnet Current for MAIN, Imag = 112.0140 A Vtrans = 1.120072 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:34:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003206051 Vs 20:34:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003201964 Vs 20:34:28 Magnet Current for MAIN, Imag = 112.0133 A Vtrans = 1.120065 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:34:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003198712 Vs 20:34:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003198311 Vs 20:34:44 Magnet Current for MAIN, Imag = 112.0131 A Vtrans = 1.120063 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:34:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003215122 Vs 20:35:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003201808 Vs 20:35:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003204364 +- 0.000003730 Vs 20:35:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003204364 +- 0.000003730 Vs BL = -0.04005455 +- 0.00004662 Tm 20:35:04 Position moved: 0.000000 m 20:35:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04005 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04005 0.00005 -0.04005 0.00000 20:35:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04005 0.00005 SL = -0.0400545 +- 0.0000466 Tm^2/m^n 20:35:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0400545 +- 0.0000466 Tm^2/m^n Remeasure 20:35:04 Magnetic Field Measurement Measuring the magnet strength... 20:35:04 Integrated Voltage Measurement... 20:35:05 Magnet Current for MAIN, Imag = 112.0135 A Vtrans = 1.120067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:35:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003211135 Vs 20:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003201033 Vs 20:35:22 Magnet Current for MAIN, Imag = 112.0137 A Vtrans = 1.120069 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:35:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003213640 Vs 20:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003195466 Vs 20:35:39 Magnet Current for MAIN, Imag = 112.0136 A Vtrans = 1.120068 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003205113 Vs 20:35:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003200142 Vs 20:35:55 Magnet Current for MAIN, Imag = 112.0143 A Vtrans = 1.120075 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:36:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003216026 Vs 20:36:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.003209633 Vs 20:36:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.003206523 +- 0.000003841 Vs 20:36:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.003206523 +- 0.000003841 Vs BL = -0.04008154 +- 0.00004802 Tm 20:36:14 Position moved: 0.000000 m 20:36:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04008 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04008 0.00005 -0.04008 0.00000 20:36:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04008 0.00005 SL = -0.0400815 +- 0.0000480 Tm^2/m^n 20:36:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0400815 +- 0.0000480 Tm^2/m^n 20:36:17 Position moved: 0.000000 m 20:36:17 Magnet system MAIN current ramping to 98.0000 A... 20:36:32 Magnet Current for MAIN, Imag = 97.9067 A Vtrans = 0.978999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:36:33 MAIN (V) Voltage Measurement, V = 3.825254 V 20:36:34 Temperature Measurement, Probe Number = 0, T = 30.256000 C 20:36:34 Temperature Measurement, Probe Number = 1, T = 29.252000 C 20:36:35 Temperature Measurement, Probe Number = 2, T = 28.462000 C 20:36:35 Temperature Measurement, Probe Number = 3, T = 28.951000 C 20:36:36 Temperature Measurement, Probe Number = 4, T = 27.378000 C 20:36:37 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006936 V 20:36:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006936 (V, A, ohm, ...), Measured Value = 0.520237 (C, atm, Hz, ...) 20:36:37 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002413 V 20:36:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002413 (V, A, ohm, ...), Measured Value = 0.180975 (C, atm, Hz, ...) 20:36:38 Sensor Voltage Measurement, Sensor Number = 2, V = -0.018193 V 20:36:38 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.018193 (V, A, ohm, ...), Measured Value = -0.003090 (C, atm, Hz, ...) 20:36:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 97.91 P1 = MAIN (V), Value = 3.83 P2 = Yoke, Value = 30.26 P3 = Coil, Value = 29.25 P4 = H20_In, Value = 28.46 P5 = H2O_Out, Value = 28.95 P6 = Ambient, Value = 27.38 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.18 P9 = Flow Rate(gpm), Value = -0.00 20:36:38 Magnetic Field Measurement Measuring the magnet strength... 20:36:38 Integrated Voltage Measurement... 20:36:39 Magnet Current for MAIN, Imag = 97.9072 A Vtrans = 0.979004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:36:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002803788 Vs 20:36:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002803650 Vs 20:36:57 Magnet Current for MAIN, Imag = 97.9069 A Vtrans = 0.979001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002809423 Vs 20:37:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002807194 Vs 20:37:13 Magnet Current for MAIN, Imag = 97.9069 A Vtrans = 0.979001 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:37:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002816715 Vs 20:37:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002802946 Vs 20:37:29 Magnet Current for MAIN, Imag = 97.9071 A Vtrans = 0.979003 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:37:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002811365 Vs 20:37:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002798490 Vs 20:37:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002806696 +- 0.000002471 Vs 20:37:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002806696 +- 0.000002471 Vs BL = -0.03508371 +- 0.00003088 Tm 20:37:49 Position moved: 0.000000 m 20:37:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03508 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03508 0.00003 -0.03508 0.00000 20:37:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03508 0.00003 SL = -0.0350837 +- 0.0000309 Tm^2/m^n 20:37:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0350837 +- 0.0000309 Tm^2/m^n Remeasure 20:37:49 Magnetic Field Measurement Measuring the magnet strength... 20:37:49 Integrated Voltage Measurement... 20:37:50 Magnet Current for MAIN, Imag = 97.9067 A Vtrans = 0.978999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:37:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002808864 Vs 20:38:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002798064 Vs 20:38:07 Magnet Current for MAIN, Imag = 97.9075 A Vtrans = 0.979007 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:38:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002805312 Vs 20:38:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002796260 Vs 20:38:24 Magnet Current for MAIN, Imag = 97.9066 A Vtrans = 0.978998 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:38:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002813911 Vs 20:38:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002806010 Vs 20:38:40 Magnet Current for MAIN, Imag = 97.9073 A Vtrans = 0.979005 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:38:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002806332 Vs 20:38:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002801228 Vs 20:38:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002804498 +- 0.000003362 Vs 20:38:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002804498 +- 0.000003362 Vs BL = -0.03505622 +- 0.00004202 Tm 20:38:59 Position moved: 0.000000 m 20:38:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03506 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03506 0.00004 -0.03506 0.00000 20:38:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03506 0.00004 SL = -0.0350562 +- 0.0000420 Tm^2/m^n 20:38:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0350562 +- 0.0000420 Tm^2/m^n Remeasure 20:38:59 Magnetic Field Measurement Measuring the magnet strength... 20:38:59 Integrated Voltage Measurement... 20:39:00 Magnet Current for MAIN, Imag = 97.9075 A Vtrans = 0.979007 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:39:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002811996 Vs 20:39:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002806113 Vs 20:39:18 Magnet Current for MAIN, Imag = 97.9066 A Vtrans = 0.978998 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:39:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002797652 Vs 20:39:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002804594 Vs 20:39:34 Magnet Current for MAIN, Imag = 97.9072 A Vtrans = 0.979004 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:39:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002792914 Vs 20:39:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002801682 Vs 20:39:50 Magnet Current for MAIN, Imag = 97.9067 A Vtrans = 0.978999 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002823068 Vs 20:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002809070 Vs 20:40:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002805886 +- 0.000007249 Vs 20:40:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002805886 +- 0.000007249 Vs BL = -0.03507358 +- 0.00009061 Tm 20:40:10 Position moved: 0.000000 m 20:40:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03507 0.00009 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03507 0.00009 -0.03507 0.00000 20:40:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03507 0.00009 SL = -0.0350736 +- 0.0000906 Tm^2/m^n 20:40:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0350736 +- 0.0000906 Tm^2/m^n 20:40:13 Position moved: 0.000000 m 20:40:13 Magnet system MAIN current ramping to 84.0000 A... 20:40:28 Magnet Current for MAIN, Imag = 83.9615 A Vtrans = 0.839546 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:40:28 MAIN (V) Voltage Measurement, V = 3.277513 V 20:40:29 Temperature Measurement, Probe Number = 0, T = 30.191000 C 20:40:29 Temperature Measurement, Probe Number = 1, T = 29.175000 C 20:40:30 Temperature Measurement, Probe Number = 2, T = 28.438000 C 20:40:31 Temperature Measurement, Probe Number = 3, T = 28.825000 C 20:40:31 Temperature Measurement, Probe Number = 4, T = 27.358000 C 20:40:32 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006927 V 20:40:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006927 (V, A, ohm, ...), Measured Value = 0.519555 (C, atm, Hz, ...) 20:40:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002286 V 20:40:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002286 (V, A, ohm, ...), Measured Value = 0.171480 (C, atm, Hz, ...) 20:40:33 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002206 V 20:40:33 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002206 (V, A, ohm, ...), Measured Value = -0.000375 (C, atm, Hz, ...) 20:40:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 83.96 P1 = MAIN (V), Value = 3.28 P2 = Yoke, Value = 30.19 P3 = Coil, Value = 29.18 P4 = H20_In, Value = 28.44 P5 = H2O_Out, Value = 28.82 P6 = Ambient, Value = 27.36 P7 = Supply Pres(psi), Value = 0.52 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 20:40:33 Magnetic Field Measurement Measuring the magnet strength... 20:40:33 Integrated Voltage Measurement... 20:40:34 Magnet Current for MAIN, Imag = 83.9613 A Vtrans = 0.839545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:40:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002409496 Vs 20:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002407254 Vs 20:40:52 Magnet Current for MAIN, Imag = 83.9616 A Vtrans = 0.839548 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:40:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002410856 Vs 20:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002410742 Vs 20:41:08 Magnet Current for MAIN, Imag = 83.9615 A Vtrans = 0.839547 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:41:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002402707 Vs 20:41:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002412177 Vs 20:41:24 Magnet Current for MAIN, Imag = 83.9612 A Vtrans = 0.839544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:41:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002408100 Vs 20:41:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002420024 Vs 20:41:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002410169 +- 0.000002560 Vs 20:41:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002410169 +- 0.000002560 Vs BL = -0.03012712 +- 0.00003200 Tm 20:41:44 Position moved: 0.000000 m 20:41:44 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03013 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03013 0.00003 -0.03013 0.00000 20:41:44 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03013 0.00003 SL = -0.0301271 +- 0.0000320 Tm^2/m^n 20:41:44 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0301271 +- 0.0000320 Tm^2/m^n Remeasure 20:41:44 Magnetic Field Measurement Measuring the magnet strength... 20:41:44 Integrated Voltage Measurement... 20:41:44 Magnet Current for MAIN, Imag = 83.9620 A Vtrans = 0.839552 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:41:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002404440 Vs 20:42:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002414803 Vs 20:42:02 Magnet Current for MAIN, Imag = 83.9613 A Vtrans = 0.839545 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:42:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002397170 Vs 20:42:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002406638 Vs 20:42:19 Magnet Current for MAIN, Imag = 83.9608 A Vtrans = 0.839540 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:42:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002408935 Vs 20:42:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002410766 Vs 20:42:35 Magnet Current for MAIN, Imag = 83.9608 A Vtrans = 0.839539 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:42:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002402611 Vs 20:42:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002408225 Vs 20:42:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002406699 +- 0.000003283 Vs 20:42:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002406699 +- 0.000003283 Vs BL = -0.03008373 +- 0.00004103 Tm 20:42:55 Position moved: 0.000000 m 20:42:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03008 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03008 0.00004 -0.03008 0.00000 20:42:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03008 0.00004 SL = -0.0300837 +- 0.0000410 Tm^2/m^n 20:42:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0300837 +- 0.0000410 Tm^2/m^n Remeasure 20:42:55 Magnetic Field Measurement Measuring the magnet strength... 20:42:55 Integrated Voltage Measurement... 20:42:56 Magnet Current for MAIN, Imag = 83.9605 A Vtrans = 0.839537 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:43:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002390972 Vs 20:43:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002411977 Vs 20:43:13 Magnet Current for MAIN, Imag = 83.9604 A Vtrans = 0.839536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:43:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002401265 Vs 20:43:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002407820 Vs 20:43:29 Magnet Current for MAIN, Imag = 83.9612 A Vtrans = 0.839544 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:43:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002412637 Vs 20:43:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002404888 Vs 20:43:45 Magnet Current for MAIN, Imag = 83.9604 A Vtrans = 0.839536 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:43:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002407731 Vs 20:44:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002411329 Vs 20:44:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002406077 +- 0.000003266 Vs 20:44:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002406077 +- 0.000003266 Vs BL = -0.03007597 +- 0.00004083 Tm 20:44:05 Position moved: 0.000000 m 20:44:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03008 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03008 0.00004 -0.03008 0.00000 20:44:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03008 0.00004 SL = -0.0300760 +- 0.0000408 Tm^2/m^n 20:44:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0300760 +- 0.0000408 Tm^2/m^n 20:44:08 Position moved: 0.000000 m 20:44:08 Magnet system MAIN current ramping to 70.0000 A... 20:44:23 Magnet Current for MAIN, Imag = 69.8560 A Vtrans = 0.698492 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:44:23 MAIN (V) Voltage Measurement, V = 2.724687 V 20:44:24 Temperature Measurement, Probe Number = 0, T = 30.118000 C 20:44:24 Temperature Measurement, Probe Number = 1, T = 29.068000 C 20:44:25 Temperature Measurement, Probe Number = 2, T = 28.425000 C 20:44:26 Temperature Measurement, Probe Number = 3, T = 28.691000 C 20:44:26 Temperature Measurement, Probe Number = 4, T = 27.381000 C 20:44:27 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006844 V 20:44:27 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006844 (V, A, ohm, ...), Measured Value = 0.513263 (C, atm, Hz, ...) 20:44:28 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002210 V 20:44:28 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002210 (V, A, ohm, ...), Measured Value = 0.165765 (C, atm, Hz, ...) 20:44:28 Sensor Voltage Measurement, Sensor Number = 2, V = -0.003008 V 20:44:28 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.003008 (V, A, ohm, ...), Measured Value = -0.000511 (C, atm, Hz, ...) 20:44:28 Magnet Test Parameter Measurements P0 = MAIN, Value = 69.86 P1 = MAIN (V), Value = 2.72 P2 = Yoke, Value = 30.12 P3 = Coil, Value = 29.07 P4 = H20_In, Value = 28.43 P5 = H2O_Out, Value = 28.69 P6 = Ambient, Value = 27.38 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 20:44:28 Magnetic Field Measurement Measuring the magnet strength... 20:44:28 Integrated Voltage Measurement... 20:44:29 Magnet Current for MAIN, Imag = 69.8558 A Vtrans = 0.698490 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:44:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001998440 Vs 20:44:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002005578 Vs 20:44:47 Magnet Current for MAIN, Imag = 69.8559 A Vtrans = 0.698491 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:44:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002020334 Vs 20:45:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002004689 Vs 20:45:03 Magnet Current for MAIN, Imag = 69.8556 A Vtrans = 0.698488 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002018872 Vs 20:45:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002006758 Vs 20:45:20 Magnet Current for MAIN, Imag = 69.8561 A Vtrans = 0.698493 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001999544 Vs 20:45:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002010515 Vs 20:45:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002008091 +- 0.000004696 Vs 20:45:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002008091 +- 0.000004696 Vs BL = -0.02510114 +- 0.00005870 Tm 20:45:40 Position moved: 0.000000 m 20:45:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02510 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02510 0.00006 -0.02510 0.00000 20:45:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02510 0.00006 SL = -0.0251011 +- 0.0000587 Tm^2/m^n 20:45:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0251011 +- 0.0000587 Tm^2/m^n Remeasure 20:45:40 Magnetic Field Measurement Measuring the magnet strength... 20:45:40 Integrated Voltage Measurement... 20:45:41 Magnet Current for MAIN, Imag = 69.8558 A Vtrans = 0.698490 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:45:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001994691 Vs 20:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002008798 Vs 20:45:58 Magnet Current for MAIN, Imag = 69.8562 A Vtrans = 0.698494 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002007502 Vs 20:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002004346 Vs 20:46:15 Magnet Current for MAIN, Imag = 69.8561 A Vtrans = 0.698493 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:46:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002008812 Vs 20:46:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002005145 Vs 20:46:32 Magnet Current for MAIN, Imag = 69.8557 A Vtrans = 0.698489 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:46:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002005859 Vs 20:46:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002005006 Vs 20:46:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002005020 +- 0.000001972 Vs 20:46:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002005020 +- 0.000001972 Vs BL = -0.02506275 +- 0.00002465 Tm 20:46:51 Position moved: 0.000000 m 20:46:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02506 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02506 0.00002 -0.02506 0.00000 20:46:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02506 0.00002 SL = -0.0250627 +- 0.0000246 Tm^2/m^n 20:46:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0250627 +- 0.0000246 Tm^2/m^n Remeasure 20:46:52 Magnetic Field Measurement Measuring the magnet strength... 20:46:52 Integrated Voltage Measurement... 20:46:52 Magnet Current for MAIN, Imag = 69.8554 A Vtrans = 0.698486 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002008213 Vs 20:47:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002006290 Vs 20:47:10 Magnet Current for MAIN, Imag = 69.8557 A Vtrans = 0.698489 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002012300 Vs 20:47:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002008568 Vs 20:47:27 Magnet Current for MAIN, Imag = 69.8552 A Vtrans = 0.698484 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002011229 Vs 20:47:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002007324 Vs 20:47:43 Magnet Current for MAIN, Imag = 69.8557 A Vtrans = 0.698489 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:47:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002011745 Vs 20:47:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.002009857 Vs 20:47:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.002009441 +- 0.000001384 Vs 20:47:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.002009441 +- 0.000001384 Vs BL = -0.02511801 +- 0.00001730 Tm 20:48:03 Position moved: 0.000000 m 20:48:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02512 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02512 0.00002 -0.02512 0.00000 20:48:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02512 0.00002 SL = -0.0251180 +- 0.0000173 Tm^2/m^n 20:48:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0251180 +- 0.0000173 Tm^2/m^n 20:48:06 Position moved: 0.000000 m 20:48:06 Magnet system MAIN current ramping to 56.0000 A... 20:48:21 Magnet Current for MAIN, Imag = 55.8994 A Vtrans = 0.558926 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:48:22 MAIN (V) Voltage Measurement, V = 2.178415 V 20:48:23 Temperature Measurement, Probe Number = 0, T = 30.043000 C 20:48:23 Temperature Measurement, Probe Number = 1, T = 29.006000 C 20:48:24 Temperature Measurement, Probe Number = 2, T = 28.414000 C 20:48:24 Temperature Measurement, Probe Number = 3, T = 28.563000 C 20:48:25 Temperature Measurement, Probe Number = 4, T = 27.290000 C 20:48:26 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006819 V 20:48:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006819 (V, A, ohm, ...), Measured Value = 0.511418 (C, atm, Hz, ...) 20:48:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002298 V 20:48:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002298 (V, A, ohm, ...), Measured Value = 0.172350 (C, atm, Hz, ...) 20:48:27 Sensor Voltage Measurement, Sensor Number = 2, V = 0.000027 V 20:48:27 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = 0.000027 (V, A, ohm, ...), Measured Value = 0.000005 (C, atm, Hz, ...) 20:48:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 55.90 P1 = MAIN (V), Value = 2.18 P2 = Yoke, Value = 30.04 P3 = Coil, Value = 29.01 P4 = H20_In, Value = 28.41 P5 = H2O_Out, Value = 28.56 P6 = Ambient, Value = 27.29 P7 = Supply Pres(psi), Value = 0.51 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = 0.00 20:48:27 Magnetic Field Measurement Measuring the magnet strength... 20:48:27 Integrated Voltage Measurement... 20:48:28 Magnet Current for MAIN, Imag = 55.8997 A Vtrans = 0.558929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001608078 Vs 20:48:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001603465 Vs 20:48:45 Magnet Current for MAIN, Imag = 55.8996 A Vtrans = 0.558928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:48:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001606002 Vs 20:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001608996 Vs 20:49:02 Magnet Current for MAIN, Imag = 55.8995 A Vtrans = 0.558927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:49:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001608941 Vs 20:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001607064 Vs 20:49:18 Magnet Current for MAIN, Imag = 55.9002 A Vtrans = 0.558934 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:49:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001605704 Vs 20:49:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001609739 Vs 20:49:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001607249 +- 0.000000871 Vs 20:49:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001607249 +- 0.000000871 Vs BL = -0.02009061 +- 0.00001089 Tm 20:49:38 Position moved: 0.000000 m 20:49:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02009 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02009 0.00001 -0.02009 0.00000 20:49:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02009 0.00001 SL = -0.0200906 +- 0.0000109 Tm^2/m^n 20:49:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0200906 +- 0.0000109 Tm^2/m^n Remeasure 20:49:38 Magnetic Field Measurement Measuring the magnet strength... 20:49:38 Integrated Voltage Measurement... 20:49:39 Magnet Current for MAIN, Imag = 55.8998 A Vtrans = 0.558930 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:49:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001607339 Vs 20:49:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001602564 Vs 20:49:56 Magnet Current for MAIN, Imag = 55.9000 A Vtrans = 0.558932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:50:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001610865 Vs 20:50:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001603664 Vs 20:50:12 Magnet Current for MAIN, Imag = 55.8999 A Vtrans = 0.558931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:50:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001609893 Vs 20:50:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001603492 Vs 20:50:28 Magnet Current for MAIN, Imag = 55.8997 A Vtrans = 0.558929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:50:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001610395 Vs 20:50:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001600926 Vs 20:50:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001606142 +- 0.000000896 Vs 20:50:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001606142 +- 0.000000896 Vs BL = -0.02007678 +- 0.00001120 Tm 20:50:48 Position moved: 0.000000 m 20:50:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02008 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02008 0.00001 -0.02008 0.00000 20:50:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02008 0.00001 SL = -0.0200768 +- 0.0000112 Tm^2/m^n 20:50:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0200768 +- 0.0000112 Tm^2/m^n Remeasure 20:50:48 Magnetic Field Measurement Measuring the magnet strength... 20:50:48 Integrated Voltage Measurement... 20:50:49 Magnet Current for MAIN, Imag = 55.8997 A Vtrans = 0.558929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:50:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001612495 Vs 20:51:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001603252 Vs 20:51:06 Magnet Current for MAIN, Imag = 55.8997 A Vtrans = 0.558929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:51:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001601783 Vs 20:51:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001604589 Vs 20:51:22 Magnet Current for MAIN, Imag = 55.8995 A Vtrans = 0.558927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:51:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001610903 Vs 20:51:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001608629 Vs 20:51:38 Magnet Current for MAIN, Imag = 55.8996 A Vtrans = 0.558928 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:51:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001614497 Vs 20:51:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001602338 Vs 20:51:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001607311 +- 0.000002479 Vs 20:51:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001607311 +- 0.000002479 Vs BL = -0.02009138 +- 0.00003099 Tm 20:51:58 Position moved: 0.000000 m 20:51:58 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02009 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02009 0.00003 -0.02009 0.00000 20:51:58 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02009 0.00003 SL = -0.0200914 +- 0.0000310 Tm^2/m^n 20:51:58 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0200914 +- 0.0000310 Tm^2/m^n 20:52:01 Position moved: 0.000000 m 20:52:01 Magnet system MAIN current ramping to 42.0000 A... 20:52:16 Magnet Current for MAIN, Imag = 41.9533 A Vtrans = 0.419465 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:52:16 MAIN (V) Voltage Measurement, V = 1.633427 V 20:52:17 Temperature Measurement, Probe Number = 0, T = 29.972000 C 20:52:18 Temperature Measurement, Probe Number = 1, T = 28.936000 C 20:52:18 Temperature Measurement, Probe Number = 2, T = 28.386000 C 20:52:19 Temperature Measurement, Probe Number = 3, T = 28.406000 C 20:52:19 Temperature Measurement, Probe Number = 4, T = 27.314000 C 20:52:20 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006714 V 20:52:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006714 (V, A, ohm, ...), Measured Value = 0.503573 (C, atm, Hz, ...) 20:52:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002203 V 20:52:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002203 (V, A, ohm, ...), Measured Value = 0.165188 (C, atm, Hz, ...) 20:52:21 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002552 V 20:52:21 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002552 (V, A, ohm, ...), Measured Value = -0.000433 (C, atm, Hz, ...) 20:52:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 41.95 P1 = MAIN (V), Value = 1.63 P2 = Yoke, Value = 29.97 P3 = Coil, Value = 28.94 P4 = H20_In, Value = 28.39 P5 = H2O_Out, Value = 28.41 P6 = Ambient, Value = 27.31 P7 = Supply Pres(psi), Value = 0.50 P8 = Return Pres(psi), Value = 0.17 P9 = Flow Rate(gpm), Value = -0.00 20:52:21 Magnetic Field Measurement Measuring the magnet strength... 20:52:21 Integrated Voltage Measurement... 20:52:22 Magnet Current for MAIN, Imag = 41.9534 A Vtrans = 0.419466 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:52:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001211082 Vs 20:52:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001206654 Vs 20:52:40 Magnet Current for MAIN, Imag = 41.9532 A Vtrans = 0.419464 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:52:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001217541 Vs 20:52:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001203172 Vs 20:52:56 Magnet Current for MAIN, Imag = 41.9529 A Vtrans = 0.419461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:53:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001212275 Vs 20:53:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001208096 Vs 20:53:13 Magnet Current for MAIN, Imag = 41.9528 A Vtrans = 0.419460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:53:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001216653 Vs 20:53:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001204399 Vs 20:53:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001209984 +- 0.000000656 Vs 20:53:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001209984 +- 0.000000656 Vs BL = -0.01512480 +- 0.00000819 Tm 20:53:32 Position moved: 0.000000 m 20:53:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01512 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01512 0.00001 -0.01512 0.00000 20:53:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01512 0.00001 SL = -0.0151248 +- 0.0000082 Tm^2/m^n 20:53:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0151248 +- 0.0000082 Tm^2/m^n Remeasure 20:53:32 Magnetic Field Measurement Measuring the magnet strength... 20:53:32 Integrated Voltage Measurement... 20:53:33 Magnet Current for MAIN, Imag = 41.9527 A Vtrans = 0.419459 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:53:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001215507 Vs 20:53:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001207545 Vs 20:53:50 Magnet Current for MAIN, Imag = 41.9528 A Vtrans = 0.419460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001213234 Vs 20:54:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001207703 Vs 20:54:07 Magnet Current for MAIN, Imag = 41.9531 A Vtrans = 0.419463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:54:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001212670 Vs 20:54:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001204281 Vs 20:54:23 Magnet Current for MAIN, Imag = 41.9530 A Vtrans = 0.419462 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:54:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001214643 Vs 20:54:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001205762 Vs 20:54:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001210168 +- 0.000001095 Vs 20:54:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001210168 +- 0.000001095 Vs BL = -0.01512710 +- 0.00001369 Tm 20:54:43 Position moved: 0.000000 m 20:54:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01513 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01513 0.00001 -0.01513 0.00000 20:54:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01513 0.00001 SL = -0.0151271 +- 0.0000137 Tm^2/m^n 20:54:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0151271 +- 0.0000137 Tm^2/m^n Remeasure 20:54:43 Magnetic Field Measurement Measuring the magnet strength... 20:54:43 Integrated Voltage Measurement... 20:54:44 Magnet Current for MAIN, Imag = 41.9529 A Vtrans = 0.419461 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001213661 Vs 20:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001205037 Vs 20:55:01 Magnet Current for MAIN, Imag = 41.9528 A Vtrans = 0.419460 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:55:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001219207 Vs 20:55:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001206498 Vs 20:55:17 Magnet Current for MAIN, Imag = 41.9531 A Vtrans = 0.419463 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:55:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001213907 Vs 20:55:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001210016 Vs 20:55:33 Magnet Current for MAIN, Imag = 41.9526 A Vtrans = 0.419458 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:55:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001211822 Vs 20:55:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.001207313 Vs 20:55:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.001210933 +- 0.000001510 Vs 20:55:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.001210933 +- 0.000001510 Vs BL = -0.01513666 +- 0.00001887 Tm 20:55:53 Position moved: 0.000000 m 20:55:53 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01514 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01514 0.00002 -0.01514 0.00000 20:55:53 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01514 0.00002 SL = -0.0151367 +- 0.0000189 Tm^2/m^n 20:55:53 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0151367 +- 0.0000189 Tm^2/m^n 20:55:56 Position moved: 0.000000 m 20:55:56 Magnet system MAIN current ramping to 28.0000 A... 20:56:11 Magnet Current for MAIN, Imag = 27.8474 A Vtrans = 0.278406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:56:11 MAIN (V) Voltage Measurement, V = 1.083167 V 20:56:12 Temperature Measurement, Probe Number = 0, T = 29.893000 C 20:56:12 Temperature Measurement, Probe Number = 1, T = 28.900000 C 20:56:13 Temperature Measurement, Probe Number = 2, T = 28.367000 C 20:56:14 Temperature Measurement, Probe Number = 3, T = 28.301000 C 20:56:14 Temperature Measurement, Probe Number = 4, T = 27.269000 C 20:56:15 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006563 V 20:56:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006563 (V, A, ohm, ...), Measured Value = 0.492240 (C, atm, Hz, ...) 20:56:15 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002062 V 20:56:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002062 (V, A, ohm, ...), Measured Value = 0.154628 (C, atm, Hz, ...) 20:56:16 Sensor Voltage Measurement, Sensor Number = 2, V = -0.002944 V 20:56:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.002944 (V, A, ohm, ...), Measured Value = -0.000500 (C, atm, Hz, ...) 20:56:16 Magnet Test Parameter Measurements P0 = MAIN, Value = 27.85 P1 = MAIN (V), Value = 1.08 P2 = Yoke, Value = 29.89 P3 = Coil, Value = 28.90 P4 = H20_In, Value = 28.37 P5 = H2O_Out, Value = 28.30 P6 = Ambient, Value = 27.27 P7 = Supply Pres(psi), Value = 0.49 P8 = Return Pres(psi), Value = 0.15 P9 = Flow Rate(gpm), Value = -0.00 20:56:16 Magnetic Field Measurement Measuring the magnet strength... 20:56:16 Integrated Voltage Measurement... 20:56:17 Magnet Current for MAIN, Imag = 27.8476 A Vtrans = 0.278408 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:56:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812390 Vs 20:56:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000804213 Vs 20:56:34 Magnet Current for MAIN, Imag = 27.8474 A Vtrans = 0.278406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:56:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000814082 Vs 20:56:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000802181 Vs 20:56:51 Magnet Current for MAIN, Imag = 27.8473 A Vtrans = 0.278405 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:56:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812273 Vs 20:57:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000801469 Vs 20:57:07 Magnet Current for MAIN, Imag = 27.8474 A Vtrans = 0.278406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:57:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000814879 Vs 20:57:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000801409 Vs 20:57:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000807862 +- 0.000000576 Vs 20:57:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000807862 +- 0.000000576 Vs BL = -0.01009827 +- 0.00000720 Tm 20:57:26 Position moved: 0.000000 m 20:57:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01010 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01010 0.00001 -0.01010 0.00000 20:57:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01010 0.00001 SL = -0.0100983 +- 0.0000072 Tm^2/m^n 20:57:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0100983 +- 0.0000072 Tm^2/m^n Remeasure 20:57:26 Magnetic Field Measurement Measuring the magnet strength... 20:57:26 Integrated Voltage Measurement... 20:57:27 Magnet Current for MAIN, Imag = 27.8474 A Vtrans = 0.278406 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:57:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812373 Vs 20:57:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000804285 Vs 20:57:45 Magnet Current for MAIN, Imag = 27.8471 A Vtrans = 0.278403 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:57:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812258 Vs 20:58:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000801436 Vs 20:58:01 Magnet Current for MAIN, Imag = 27.8475 A Vtrans = 0.278407 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:58:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000812566 Vs 20:58:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000804151 Vs 20:58:18 Magnet Current for MAIN, Imag = 27.8475 A Vtrans = 0.278407 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:58:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000809814 Vs 20:58:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000805596 Vs 20:58:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000807810 +- 0.000000614 Vs 20:58:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000807810 +- 0.000000614 Vs BL = -0.01009762 +- 0.00000768 Tm 20:58:38 Position moved: 0.000000 m 20:58:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01010 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01010 0.00001 -0.01010 0.00000 20:58:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01010 0.00001 SL = -0.0100976 +- 0.0000077 Tm^2/m^n 20:58:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0100976 +- 0.0000077 Tm^2/m^n Remeasure 20:58:38 Magnetic Field Measurement Measuring the magnet strength... 20:58:38 Integrated Voltage Measurement... 20:58:38 Magnet Current for MAIN, Imag = 27.8473 A Vtrans = 0.278405 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:58:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000809334 Vs 20:58:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000806979 Vs 20:58:56 Magnet Current for MAIN, Imag = 27.8472 A Vtrans = 0.278404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:59:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000811681 Vs 20:59:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000806116 Vs 20:59:13 Magnet Current for MAIN, Imag = 27.8472 A Vtrans = 0.278404 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:59:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000810787 Vs 20:59:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000804846 Vs 20:59:30 Magnet Current for MAIN, Imag = 27.8475 A Vtrans = 0.278407 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 20:59:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000810504 Vs 20:59:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000808377 Vs 20:59:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000808578 +- 0.000000633 Vs 20:59:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000808578 +- 0.000000633 Vs BL = -0.01010723 +- 0.00000792 Tm 20:59:49 Position moved: 0.000000 m 20:59:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01011 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01011 0.00001 -0.01011 0.00000 20:59:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01011 0.00001 SL = -0.0101072 +- 0.0000079 Tm^2/m^n 20:59:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0101072 +- 0.0000079 Tm^2/m^n 20:59:52 Position moved: 0.000000 m 20:59:52 Magnet system MAIN current ramping to 14.0000 A... 21:00:07 Magnet Current for MAIN, Imag = 13.9004 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:00:08 MAIN (V) Voltage Measurement, V = 0.540029 V 21:00:08 Temperature Measurement, Probe Number = 0, T = 29.818000 C 21:00:09 Temperature Measurement, Probe Number = 1, T = 28.858000 C 21:00:10 Temperature Measurement, Probe Number = 2, T = 28.350000 C 21:00:10 Temperature Measurement, Probe Number = 3, T = 28.241000 C 21:00:11 Temperature Measurement, Probe Number = 4, T = 27.240000 C 21:00:12 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006583 V 21:00:12 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006583 (V, A, ohm, ...), Measured Value = 0.493695 (C, atm, Hz, ...) 21:00:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.002151 V 21:00:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.002151 (V, A, ohm, ...), Measured Value = 0.161310 (C, atm, Hz, ...) 21:00:13 Sensor Voltage Measurement, Sensor Number = 2, V = -0.000588 V 21:00:13 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.000588 (V, A, ohm, ...), Measured Value = -0.000100 (C, atm, Hz, ...) 21:00:13 Magnet Test Parameter Measurements P0 = MAIN, Value = 13.90 P1 = MAIN (V), Value = 0.54 P2 = Yoke, Value = 29.82 P3 = Coil, Value = 28.86 P4 = H20_In, Value = 28.35 P5 = H2O_Out, Value = 28.24 P6 = Ambient, Value = 27.24 P7 = Supply Pres(psi), Value = 0.49 P8 = Return Pres(psi), Value = 0.16 P9 = Flow Rate(gpm), Value = -0.00 21:00:13 Magnetic Field Measurement Measuring the magnet strength... 21:00:13 Integrated Voltage Measurement... 21:00:14 Magnet Current for MAIN, Imag = 13.9004 A Vtrans = 0.138936 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:00:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000408007 Vs 21:00:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000411551 Vs 21:00:31 Magnet Current for MAIN, Imag = 13.9001 A Vtrans = 0.138933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:00:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000408791 Vs 21:00:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000409640 Vs 21:00:48 Magnet Current for MAIN, Imag = 13.8999 A Vtrans = 0.138931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:00:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000410400 Vs 21:01:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000406964 Vs 21:01:04 Magnet Current for MAIN, Imag = 13.8999 A Vtrans = 0.138931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:01:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000411413 Vs 21:01:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000409007 Vs 21:01:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000409472 +- 0.000000576 Vs 21:01:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000409472 +- 0.000000576 Vs BL = -0.00511840 +- 0.00000720 Tm 21:01:23 Position moved: 0.000000 m 21:01:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00512 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00512 0.00001 -0.00512 0.00000 21:01:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00512 0.00001 SL = -0.0051184 +- 0.0000072 Tm^2/m^n 21:01:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0051184 +- 0.0000072 Tm^2/m^n Remeasure 21:01:24 Magnetic Field Measurement Measuring the magnet strength... 21:01:24 Integrated Voltage Measurement... 21:01:24 Magnet Current for MAIN, Imag = 13.9000 A Vtrans = 0.138932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:01:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000410380 Vs 21:01:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000409454 Vs 21:01:42 Magnet Current for MAIN, Imag = 13.9001 A Vtrans = 0.138933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:01:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000411114 Vs 21:01:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000408645 Vs 21:01:58 Magnet Current for MAIN, Imag = 13.8999 A Vtrans = 0.138931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:02:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000409856 Vs 21:02:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000409732 Vs 21:02:14 Magnet Current for MAIN, Imag = 13.8998 A Vtrans = 0.138930 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:02:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000410459 Vs 21:02:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000407877 Vs 21:02:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000409690 +- 0.000000304 Vs 21:02:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000409690 +- 0.000000304 Vs BL = -0.00512112 +- 0.00000380 Tm 21:02:34 Position moved: 0.000000 m 21:02:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00512 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00512 0.00000 -0.00512 0.00000 21:02:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00512 0.00000 SL = -0.0051211 +- 0.0000038 Tm^2/m^n 21:02:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0051211 +- 0.0000038 Tm^2/m^n Remeasure 21:02:34 Magnetic Field Measurement Measuring the magnet strength... 21:02:34 Integrated Voltage Measurement... 21:02:35 Magnet Current for MAIN, Imag = 13.8997 A Vtrans = 0.138929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:02:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000410521 Vs 21:02:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000408725 Vs 21:02:52 Magnet Current for MAIN, Imag = 13.8999 A Vtrans = 0.138931 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:03:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000412207 Vs 21:03:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000407798 Vs 21:03:09 Magnet Current for MAIN, Imag = 13.8997 A Vtrans = 0.138929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:03:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000410442 Vs 21:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000410121 Vs 21:03:25 Magnet Current for MAIN, Imag = 13.9000 A Vtrans = 0.138932 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:03:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000409240 Vs 21:03:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000409713 Vs 21:03:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000409846 +- 0.000000316 Vs 21:03:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000409846 +- 0.000000316 Vs BL = -0.00512307 +- 0.00000396 Tm 21:03:45 Position moved: 0.000000 m 21:03:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00512 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00512 0.00000 -0.00512 0.00000 21:03:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00512 0.00000 SL = -0.0051231 +- 0.0000040 Tm^2/m^n 21:03:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0051231 +- 0.0000040 Tm^2/m^n 21:03:48 Position moved: 0.000000 m 21:03:48 Magnet system MAIN current ramping to 0.0000 A... 21:04:03 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000065 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:04:04 MAIN (V) Voltage Measurement, V = -0.000000 V 21:04:04 Temperature Measurement, Probe Number = 0, T = 29.731000 C 21:04:05 Temperature Measurement, Probe Number = 1, T = 28.824000 C 21:04:05 Temperature Measurement, Probe Number = 2, T = 28.362000 C 21:04:06 Temperature Measurement, Probe Number = 3, T = 28.266000 C 21:04:07 Temperature Measurement, Probe Number = 4, T = 27.157000 C 21:04:07 Sensor Voltage Measurement, Sensor Number = 0, V = 1.006545 V 21:04:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.006545 (V, A, ohm, ...), Measured Value = 0.490883 (C, atm, Hz, ...) 21:04:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.001863 V 21:04:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.001863 (V, A, ohm, ...), Measured Value = 0.139702 (C, atm, Hz, ...) 21:04:09 Sensor Voltage Measurement, Sensor Number = 2, V = -0.016777 V 21:04:09 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HOFFER_FV Raw Sensor Output = -0.016777 (V, A, ohm, ...), Measured Value = -0.002849 (C, atm, Hz, ...) 21:04:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.00 P1 = MAIN (V), Value = -0.00 P2 = Yoke, Value = 29.73 P3 = Coil, Value = 28.82 P4 = H20_In, Value = 28.36 P5 = H2O_Out, Value = 28.27 P6 = Ambient, Value = 27.16 P7 = Supply Pres(psi), Value = 0.49 P8 = Return Pres(psi), Value = 0.14 P9 = Flow Rate(gpm), Value = -0.00 21:04:09 Magnetic Field Measurement Measuring the magnet strength... 21:04:09 Integrated Voltage Measurement... 21:04:10 Magnet Current for MAIN, Imag = 0.0003 A Vtrans = -0.000065 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:04:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000015548 Vs 21:04:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000011164 Vs 21:04:28 Magnet Current for MAIN, Imag = 0.0002 A Vtrans = -0.000066 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:04:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000015764 Vs 21:04:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000011068 Vs 21:04:44 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:04:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000014915 Vs 21:05:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000013802 Vs 21:05:01 Magnet Current for MAIN, Imag = 0.0001 A Vtrans = -0.000067 V, Factor V/A = 0.010000 V/A, Zero Current = -0.006804 A 21:05:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000012327 Vs 21:05:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0080000 m VT = 0.000013088 Vs 21:05:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0080000 m VT = -0.000013460 +- 0.000000589 Vs 21:05:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0080000 m, Nturns = 10.0 VT = -0.000013460 +- 0.000000589 Vs BL = -0.00016825 +- 0.00000736 Tm 21:05:21 Position moved: 0.000000 m 21:05:21 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00017 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00017 0.00001 -0.00017 0.00000 21:05:21 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00017 0.00001 SL = -0.0001682 +- 0.0000074 Tm^2/m^n 21:05:21 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001682 +- 0.0000074 Tm^2/m^n 21:05:24 Position moved: 0.000000 m 21:05:26 Position moved: 0.000000 m 21:05:29 Magnet system MAIN current ramping to 0.0000 A...