SLAC Magnetic Measurements Date: 07-13-2022 Time: 10:56:52 Project: Facet_II Magnet Type: Dipole Magnet Name: 1.18D3.17-BCX10475-3 Serial Number: 3 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated field from 0 to 185 to 0 amps in 15 amp steps. Integrated field vs X at 155 amps. 2 hr warmup at 165 A Standardization for MAIN: 3 cycles from 0.0 A to 185.0 A to 0.0 A Test Currents for MAIN (A): 0.00 15.00 30.00 45.00 60.00 75.00 90.00 105.00 120.00 135.00 150.00 165.00 180.00 185.00 180.00 165.00 150.00 135.00 120.00 105.00 90.00 75.00 60.00 45.00 30.00 15.00 0.00 155.00 155.00 155.00 10:57:19 Position moved: 0.000000 m 10:57:22 Magnet Current for MAIN, Imag = 0.0057 A Vtrans = 0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:57:23 Magnet Current for MAIN, Imag = 0.0057 A Vtrans = 0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:57:23 Magnet Current for MAIN, Imag = 0.0057 A Vtrans = 0.000057 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:57:24 Magnet Current for MAIN, Imag = 0.0058 A Vtrans = 0.000058 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 10:57:24 Magnet Avgerage Current Measurement for MAIN : Imag = 0.0057 +- 0.0000 A 10:57:46 Initial Zero Current Measurement for MAIN, Imag_zero = 0.00573305 A 10:57:46 Ambient Measurement Device(s) Being Used, type = None 10:57:46 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 10:57:47 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 10:57:47 XMAG Device(s) Being Used, type = None 10:57:47 Ambient Measurement Device(s) Being Used, type = HP34970 10:57:47 Magnet system MAIN current ramping to 165.0000 A... 10:57:59 Magnet Current for MAIN, Imag = 164.9724 A Vtrans = 1.649782 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 10:58:00 MAIN (V) Voltage Measurement, V = 6.530901 V 10:58:06 Temperature Measurement, Probe Number = 0, T = 24.706000 C 10:58:07 Temperature Measurement, Probe Number = 1, T = 26.647000 C 10:58:07 Temperature Measurement, Probe Number = 2, T = 26.937000 C 10:58:08 Temperature Measurement, Probe Number = 3, T = 28.714000 C 10:58:09 Temperature Measurement, Probe Number = 4, T = 28.564000 C 10:58:09 Temperature Measurement, Probe Number = 5, T = 23.689000 C 10:58:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.678057 V 10:58:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.678057 (V, A, ohm, ...), Measured Value = 125.854245 (C, atm, Hz, ...) 10:58:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155374 V 10:58:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155374 (V, A, ohm, ...), Measured Value = 11.653020 (C, atm, Hz, ...) 10:58:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.53 P2 = Yoke, Value = 24.71 P3 = Bottom Coil, Value = 26.65 P4 = Top Coil, Value = 26.94 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 28.56 P7 = Ambient, Value = 23.69 P8 = Supply Pres(psi), Value = 125.85 P9 = Return Pres(psi), Value = 11.65 10:59:11 Magnet Current for MAIN, Imag = 164.9728 A Vtrans = 1.649785 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 10:59:12 MAIN (V) Voltage Measurement, V = 6.540108 V 10:59:15 Temperature Measurement, Probe Number = 0, T = 24.677000 C 10:59:16 Temperature Measurement, Probe Number = 1, T = 27.174000 C 10:59:17 Temperature Measurement, Probe Number = 2, T = 27.457000 C 10:59:17 Temperature Measurement, Probe Number = 3, T = 28.715000 C 10:59:18 Temperature Measurement, Probe Number = 4, T = 29.676000 C 10:59:18 Temperature Measurement, Probe Number = 5, T = 23.693000 C 10:59:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.644820 V 10:59:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644820 (V, A, ohm, ...), Measured Value = 123.361470 (C, atm, Hz, ...) 10:59:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157227 V 10:59:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157227 (V, A, ohm, ...), Measured Value = 11.791995 (C, atm, Hz, ...) 10:59:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.68 P3 = Bottom Coil, Value = 27.17 P4 = Top Coil, Value = 27.46 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 29.68 P7 = Ambient, Value = 23.69 P8 = Supply Pres(psi), Value = 123.36 P9 = Return Pres(psi), Value = 11.79 11:00:20 Magnet Current for MAIN, Imag = 164.9740 A Vtrans = 1.649798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:00:21 MAIN (V) Voltage Measurement, V = 6.540737 V 11:00:24 Temperature Measurement, Probe Number = 0, T = 24.693000 C 11:00:25 Temperature Measurement, Probe Number = 1, T = 27.375000 C 11:00:26 Temperature Measurement, Probe Number = 2, T = 27.715000 C 11:00:26 Temperature Measurement, Probe Number = 3, T = 28.712000 C 11:00:27 Temperature Measurement, Probe Number = 4, T = 30.136000 C 11:00:27 Temperature Measurement, Probe Number = 5, T = 23.664000 C 11:00:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.682091 V 11:00:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.682091 (V, A, ohm, ...), Measured Value = 126.156825 (C, atm, Hz, ...) 11:00:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155573 V 11:00:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155573 (V, A, ohm, ...), Measured Value = 11.668005 (C, atm, Hz, ...) 11:00:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.69 P3 = Bottom Coil, Value = 27.38 P4 = Top Coil, Value = 27.71 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 30.14 P7 = Ambient, Value = 23.66 P8 = Supply Pres(psi), Value = 126.16 P9 = Return Pres(psi), Value = 11.67 11:01:29 Magnet Current for MAIN, Imag = 164.9734 A Vtrans = 1.649791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:01:30 MAIN (V) Voltage Measurement, V = 6.541097 V 11:01:33 Temperature Measurement, Probe Number = 0, T = 24.690000 C 11:01:34 Temperature Measurement, Probe Number = 1, T = 27.470000 C 11:01:35 Temperature Measurement, Probe Number = 2, T = 27.858000 C 11:01:35 Temperature Measurement, Probe Number = 3, T = 28.706000 C 11:01:36 Temperature Measurement, Probe Number = 4, T = 30.349000 C 11:01:36 Temperature Measurement, Probe Number = 5, T = 23.692000 C 11:01:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659096 V 11:01:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659096 (V, A, ohm, ...), Measured Value = 124.432170 (C, atm, Hz, ...) 11:01:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155498 V 11:01:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155498 (V, A, ohm, ...), Measured Value = 11.662387 (C, atm, Hz, ...) 11:01:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.69 P3 = Bottom Coil, Value = 27.47 P4 = Top Coil, Value = 27.86 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 30.35 P7 = Ambient, Value = 23.69 P8 = Supply Pres(psi), Value = 124.43 P9 = Return Pres(psi), Value = 11.66 11:02:38 Magnet Current for MAIN, Imag = 164.9737 A Vtrans = 1.649794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:02:39 MAIN (V) Voltage Measurement, V = 6.541412 V 11:02:42 Temperature Measurement, Probe Number = 0, T = 24.713000 C 11:02:43 Temperature Measurement, Probe Number = 1, T = 27.478000 C 11:02:44 Temperature Measurement, Probe Number = 2, T = 28.069000 C 11:02:44 Temperature Measurement, Probe Number = 3, T = 28.698000 C 11:02:45 Temperature Measurement, Probe Number = 4, T = 30.445000 C 11:02:45 Temperature Measurement, Probe Number = 5, T = 23.758000 C 11:02:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.684341 V 11:02:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.684341 (V, A, ohm, ...), Measured Value = 126.325583 (C, atm, Hz, ...) 11:02:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155590 V 11:02:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155590 (V, A, ohm, ...), Measured Value = 11.669220 (C, atm, Hz, ...) 11:02:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.71 P3 = Bottom Coil, Value = 27.48 P4 = Top Coil, Value = 28.07 P5 = Water In, Value = 28.70 P6 = Water Out, Value = 30.45 P7 = Ambient, Value = 23.76 P8 = Supply Pres(psi), Value = 126.33 P9 = Return Pres(psi), Value = 11.67 11:03:47 Magnet Current for MAIN, Imag = 164.9738 A Vtrans = 1.649795 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:03:48 MAIN (V) Voltage Measurement, V = 6.541842 V 11:03:52 Temperature Measurement, Probe Number = 0, T = 24.722000 C 11:03:52 Temperature Measurement, Probe Number = 1, T = 27.520000 C 11:03:53 Temperature Measurement, Probe Number = 2, T = 28.085000 C 11:03:53 Temperature Measurement, Probe Number = 3, T = 28.742000 C 11:03:54 Temperature Measurement, Probe Number = 4, T = 30.522000 C 11:03:54 Temperature Measurement, Probe Number = 5, T = 23.757000 C 11:03:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.648285 V 11:03:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648285 (V, A, ohm, ...), Measured Value = 123.621345 (C, atm, Hz, ...) 11:03:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154729 V 11:03:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154729 (V, A, ohm, ...), Measured Value = 11.604698 (C, atm, Hz, ...) 11:03:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.72 P3 = Bottom Coil, Value = 27.52 P4 = Top Coil, Value = 28.09 P5 = Water In, Value = 28.74 P6 = Water Out, Value = 30.52 P7 = Ambient, Value = 23.76 P8 = Supply Pres(psi), Value = 123.62 P9 = Return Pres(psi), Value = 11.60 11:04:56 Magnet Current for MAIN, Imag = 164.9740 A Vtrans = 1.649798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:04:57 MAIN (V) Voltage Measurement, V = 6.541854 V 11:05:01 Temperature Measurement, Probe Number = 0, T = 24.729000 C 11:05:01 Temperature Measurement, Probe Number = 1, T = 27.532000 C 11:05:02 Temperature Measurement, Probe Number = 2, T = 28.060000 C 11:05:02 Temperature Measurement, Probe Number = 3, T = 28.744000 C 11:05:03 Temperature Measurement, Probe Number = 4, T = 30.549000 C 11:05:03 Temperature Measurement, Probe Number = 5, T = 23.832000 C 11:05:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.644715 V 11:05:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644715 (V, A, ohm, ...), Measured Value = 123.353603 (C, atm, Hz, ...) 11:05:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156577 V 11:05:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156577 (V, A, ohm, ...), Measured Value = 11.743297 (C, atm, Hz, ...) 11:05:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.73 P3 = Bottom Coil, Value = 27.53 P4 = Top Coil, Value = 28.06 P5 = Water In, Value = 28.74 P6 = Water Out, Value = 30.55 P7 = Ambient, Value = 23.83 P8 = Supply Pres(psi), Value = 123.35 P9 = Return Pres(psi), Value = 11.74 11:06:05 Magnet Current for MAIN, Imag = 164.9745 A Vtrans = 1.649803 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:06:06 MAIN (V) Voltage Measurement, V = 6.541297 V 11:06:10 Temperature Measurement, Probe Number = 0, T = 24.723000 C 11:06:10 Temperature Measurement, Probe Number = 1, T = 27.633000 C 11:06:11 Temperature Measurement, Probe Number = 2, T = 28.133000 C 11:06:11 Temperature Measurement, Probe Number = 3, T = 28.723000 C 11:06:12 Temperature Measurement, Probe Number = 4, T = 30.563000 C 11:06:12 Temperature Measurement, Probe Number = 5, T = 23.821000 C 11:06:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666469 V 11:06:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666469 (V, A, ohm, ...), Measured Value = 124.985175 (C, atm, Hz, ...) 11:06:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156600 V 11:06:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156600 (V, A, ohm, ...), Measured Value = 11.744985 (C, atm, Hz, ...) 11:06:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.97 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.72 P3 = Bottom Coil, Value = 27.63 P4 = Top Coil, Value = 28.13 P5 = Water In, Value = 28.72 P6 = Water Out, Value = 30.56 P7 = Ambient, Value = 23.82 P8 = Supply Pres(psi), Value = 124.99 P9 = Return Pres(psi), Value = 11.74 11:07:14 Magnet Current for MAIN, Imag = 164.9750 A Vtrans = 1.649808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:07:15 MAIN (V) Voltage Measurement, V = 6.540570 V 11:07:19 Temperature Measurement, Probe Number = 0, T = 24.768000 C 11:07:19 Temperature Measurement, Probe Number = 1, T = 27.554000 C 11:07:20 Temperature Measurement, Probe Number = 2, T = 28.108000 C 11:07:20 Temperature Measurement, Probe Number = 3, T = 28.684000 C 11:07:21 Temperature Measurement, Probe Number = 4, T = 30.548000 C 11:07:21 Temperature Measurement, Probe Number = 5, T = 23.868000 C 11:07:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.649588 V 11:07:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649588 (V, A, ohm, ...), Measured Value = 123.719115 (C, atm, Hz, ...) 11:07:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157395 V 11:07:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157395 (V, A, ohm, ...), Measured Value = 11.804640 (C, atm, Hz, ...) 11:07:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.77 P3 = Bottom Coil, Value = 27.55 P4 = Top Coil, Value = 28.11 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.55 P7 = Ambient, Value = 23.87 P8 = Supply Pres(psi), Value = 123.72 P9 = Return Pres(psi), Value = 11.80 11:08:23 Magnet Current for MAIN, Imag = 164.9752 A Vtrans = 1.649809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:08:24 MAIN (V) Voltage Measurement, V = 6.539898 V 11:08:28 Temperature Measurement, Probe Number = 0, T = 24.790000 C 11:08:28 Temperature Measurement, Probe Number = 1, T = 27.471000 C 11:08:29 Temperature Measurement, Probe Number = 2, T = 27.966000 C 11:08:29 Temperature Measurement, Probe Number = 3, T = 28.640000 C 11:08:30 Temperature Measurement, Probe Number = 4, T = 30.516000 C 11:08:30 Temperature Measurement, Probe Number = 5, T = 23.877000 C 11:08:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.672617 V 11:08:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672617 (V, A, ohm, ...), Measured Value = 125.446305 (C, atm, Hz, ...) 11:08:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.159457 V 11:08:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.159457 (V, A, ohm, ...), Measured Value = 11.959252 (C, atm, Hz, ...) 11:08:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.79 P3 = Bottom Coil, Value = 27.47 P4 = Top Coil, Value = 27.97 P5 = Water In, Value = 28.64 P6 = Water Out, Value = 30.52 P7 = Ambient, Value = 23.88 P8 = Supply Pres(psi), Value = 125.45 P9 = Return Pres(psi), Value = 11.96 11:09:32 Magnet Current for MAIN, Imag = 164.9750 A Vtrans = 1.649808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:09:33 MAIN (V) Voltage Measurement, V = 6.539658 V 11:09:37 Temperature Measurement, Probe Number = 0, T = 24.789000 C 11:09:37 Temperature Measurement, Probe Number = 1, T = 27.566000 C 11:09:38 Temperature Measurement, Probe Number = 2, T = 27.999000 C 11:09:38 Temperature Measurement, Probe Number = 3, T = 28.634000 C 11:09:39 Temperature Measurement, Probe Number = 4, T = 30.502000 C 11:09:40 Temperature Measurement, Probe Number = 5, T = 23.880000 C 11:09:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659822 V 11:09:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659822 (V, A, ohm, ...), Measured Value = 124.486673 (C, atm, Hz, ...) 11:09:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155957 V 11:09:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155957 (V, A, ohm, ...), Measured Value = 11.696752 (C, atm, Hz, ...) 11:09:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.79 P3 = Bottom Coil, Value = 27.57 P4 = Top Coil, Value = 28.00 P5 = Water In, Value = 28.63 P6 = Water Out, Value = 30.50 P7 = Ambient, Value = 23.88 P8 = Supply Pres(psi), Value = 124.49 P9 = Return Pres(psi), Value = 11.70 11:10:41 Magnet Current for MAIN, Imag = 164.9755 A Vtrans = 1.649813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:10:42 MAIN (V) Voltage Measurement, V = 6.539636 V 11:10:46 Temperature Measurement, Probe Number = 0, T = 24.787000 C 11:10:46 Temperature Measurement, Probe Number = 1, T = 27.564000 C 11:10:47 Temperature Measurement, Probe Number = 2, T = 27.946000 C 11:10:47 Temperature Measurement, Probe Number = 3, T = 28.655000 C 11:10:48 Temperature Measurement, Probe Number = 4, T = 30.488000 C 11:10:49 Temperature Measurement, Probe Number = 5, T = 23.878000 C 11:10:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666319 V 11:10:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666319 (V, A, ohm, ...), Measured Value = 124.973932 (C, atm, Hz, ...) 11:10:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155832 V 11:10:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155832 (V, A, ohm, ...), Measured Value = 11.687392 (C, atm, Hz, ...) 11:10:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.79 P3 = Bottom Coil, Value = 27.56 P4 = Top Coil, Value = 27.95 P5 = Water In, Value = 28.66 P6 = Water Out, Value = 30.49 P7 = Ambient, Value = 23.88 P8 = Supply Pres(psi), Value = 124.97 P9 = Return Pres(psi), Value = 11.69 11:11:50 Magnet Current for MAIN, Imag = 164.9754 A Vtrans = 1.649811 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:11:51 MAIN (V) Voltage Measurement, V = 6.539674 V 11:11:55 Temperature Measurement, Probe Number = 0, T = 24.812000 C 11:11:55 Temperature Measurement, Probe Number = 1, T = 27.538000 C 11:11:56 Temperature Measurement, Probe Number = 2, T = 27.966000 C 11:11:56 Temperature Measurement, Probe Number = 3, T = 28.653000 C 11:11:57 Temperature Measurement, Probe Number = 4, T = 30.478000 C 11:11:58 Temperature Measurement, Probe Number = 5, T = 23.972000 C 11:11:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.681849 V 11:11:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.681849 (V, A, ohm, ...), Measured Value = 126.138660 (C, atm, Hz, ...) 11:11:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156168 V 11:11:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156168 (V, A, ohm, ...), Measured Value = 11.712577 (C, atm, Hz, ...) 11:11:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.81 P3 = Bottom Coil, Value = 27.54 P4 = Top Coil, Value = 27.97 P5 = Water In, Value = 28.65 P6 = Water Out, Value = 30.48 P7 = Ambient, Value = 23.97 P8 = Supply Pres(psi), Value = 126.14 P9 = Return Pres(psi), Value = 11.71 11:12:59 Magnet Current for MAIN, Imag = 164.9753 A Vtrans = 1.649810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:13:00 MAIN (V) Voltage Measurement, V = 6.539437 V 11:13:04 Temperature Measurement, Probe Number = 0, T = 24.835000 C 11:13:04 Temperature Measurement, Probe Number = 1, T = 27.529000 C 11:13:05 Temperature Measurement, Probe Number = 2, T = 28.002000 C 11:13:05 Temperature Measurement, Probe Number = 3, T = 28.643000 C 11:13:06 Temperature Measurement, Probe Number = 4, T = 30.478000 C 11:13:07 Temperature Measurement, Probe Number = 5, T = 23.989000 C 11:13:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.673606 V 11:13:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.673606 (V, A, ohm, ...), Measured Value = 125.520472 (C, atm, Hz, ...) 11:13:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155946 V 11:13:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155946 (V, A, ohm, ...), Measured Value = 11.695913 (C, atm, Hz, ...) 11:13:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.84 P3 = Bottom Coil, Value = 27.53 P4 = Top Coil, Value = 28.00 P5 = Water In, Value = 28.64 P6 = Water Out, Value = 30.48 P7 = Ambient, Value = 23.99 P8 = Supply Pres(psi), Value = 125.52 P9 = Return Pres(psi), Value = 11.70 11:14:08 Magnet Current for MAIN, Imag = 164.9757 A Vtrans = 1.649814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:14:09 MAIN (V) Voltage Measurement, V = 6.539375 V 11:14:13 Temperature Measurement, Probe Number = 0, T = 24.825000 C 11:14:13 Temperature Measurement, Probe Number = 1, T = 27.545000 C 11:14:14 Temperature Measurement, Probe Number = 2, T = 27.993000 C 11:14:14 Temperature Measurement, Probe Number = 3, T = 28.631000 C 11:14:15 Temperature Measurement, Probe Number = 4, T = 30.485000 C 11:14:16 Temperature Measurement, Probe Number = 5, T = 24.001000 C 11:14:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.653700 V 11:14:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653700 (V, A, ohm, ...), Measured Value = 124.027507 (C, atm, Hz, ...) 11:14:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155100 V 11:14:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155100 (V, A, ohm, ...), Measured Value = 11.632508 (C, atm, Hz, ...) 11:14:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.82 P3 = Bottom Coil, Value = 27.55 P4 = Top Coil, Value = 27.99 P5 = Water In, Value = 28.63 P6 = Water Out, Value = 30.48 P7 = Ambient, Value = 24.00 P8 = Supply Pres(psi), Value = 124.03 P9 = Return Pres(psi), Value = 11.63 11:15:17 Magnet Current for MAIN, Imag = 164.9757 A Vtrans = 1.649814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:15:18 MAIN (V) Voltage Measurement, V = 6.539491 V 11:15:22 Temperature Measurement, Probe Number = 0, T = 24.855000 C 11:15:22 Temperature Measurement, Probe Number = 1, T = 27.512000 C 11:15:23 Temperature Measurement, Probe Number = 2, T = 28.060000 C 11:15:23 Temperature Measurement, Probe Number = 3, T = 28.636000 C 11:15:24 Temperature Measurement, Probe Number = 4, T = 30.495000 C 11:15:25 Temperature Measurement, Probe Number = 5, T = 23.972000 C 11:15:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.651950 V 11:15:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651950 (V, A, ohm, ...), Measured Value = 123.896213 (C, atm, Hz, ...) 11:15:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155643 V 11:15:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155643 (V, A, ohm, ...), Measured Value = 11.673247 (C, atm, Hz, ...) 11:15:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.86 P3 = Bottom Coil, Value = 27.51 P4 = Top Coil, Value = 28.06 P5 = Water In, Value = 28.64 P6 = Water Out, Value = 30.50 P7 = Ambient, Value = 23.97 P8 = Supply Pres(psi), Value = 123.90 P9 = Return Pres(psi), Value = 11.67 11:16:26 Magnet Current for MAIN, Imag = 164.9759 A Vtrans = 1.649816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:16:27 MAIN (V) Voltage Measurement, V = 6.540553 V 11:16:31 Temperature Measurement, Probe Number = 0, T = 24.871000 C 11:16:31 Temperature Measurement, Probe Number = 1, T = 27.471000 C 11:16:32 Temperature Measurement, Probe Number = 2, T = 28.146000 C 11:16:32 Temperature Measurement, Probe Number = 3, T = 28.690000 C 11:16:33 Temperature Measurement, Probe Number = 4, T = 30.499000 C 11:16:34 Temperature Measurement, Probe Number = 5, T = 24.052000 C 11:16:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.657446 V 11:16:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657446 (V, A, ohm, ...), Measured Value = 124.308458 (C, atm, Hz, ...) 11:16:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155626 V 11:16:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155626 (V, A, ohm, ...), Measured Value = 11.671935 (C, atm, Hz, ...) 11:16:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.87 P3 = Bottom Coil, Value = 27.47 P4 = Top Coil, Value = 28.15 P5 = Water In, Value = 28.69 P6 = Water Out, Value = 30.50 P7 = Ambient, Value = 24.05 P8 = Supply Pres(psi), Value = 124.31 P9 = Return Pres(psi), Value = 11.67 11:17:35 Magnet Current for MAIN, Imag = 164.9760 A Vtrans = 1.649818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:17:36 MAIN (V) Voltage Measurement, V = 6.541320 V 11:17:40 Temperature Measurement, Probe Number = 0, T = 24.861000 C 11:17:40 Temperature Measurement, Probe Number = 1, T = 27.529000 C 11:17:41 Temperature Measurement, Probe Number = 2, T = 28.145000 C 11:17:41 Temperature Measurement, Probe Number = 3, T = 28.701000 C 11:17:42 Temperature Measurement, Probe Number = 4, T = 30.503000 C 11:17:43 Temperature Measurement, Probe Number = 5, T = 24.076000 C 11:17:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.646663 V 11:17:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.646663 (V, A, ohm, ...), Measured Value = 123.499695 (C, atm, Hz, ...) 11:17:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156038 V 11:17:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156038 (V, A, ohm, ...), Measured Value = 11.702843 (C, atm, Hz, ...) 11:17:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.86 P3 = Bottom Coil, Value = 27.53 P4 = Top Coil, Value = 28.14 P5 = Water In, Value = 28.70 P6 = Water Out, Value = 30.50 P7 = Ambient, Value = 24.08 P8 = Supply Pres(psi), Value = 123.50 P9 = Return Pres(psi), Value = 11.70 11:18:44 Magnet Current for MAIN, Imag = 164.9760 A Vtrans = 1.649818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:18:45 MAIN (V) Voltage Measurement, V = 6.541918 V 11:18:49 Temperature Measurement, Probe Number = 0, T = 24.876000 C 11:18:49 Temperature Measurement, Probe Number = 1, T = 27.634000 C 11:18:50 Temperature Measurement, Probe Number = 2, T = 28.237000 C 11:18:50 Temperature Measurement, Probe Number = 3, T = 28.712000 C 11:18:51 Temperature Measurement, Probe Number = 4, T = 30.529000 C 11:18:52 Temperature Measurement, Probe Number = 5, T = 24.106000 C 11:18:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.647389 V 11:18:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647389 (V, A, ohm, ...), Measured Value = 123.554198 (C, atm, Hz, ...) 11:18:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156772 V 11:18:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156772 (V, A, ohm, ...), Measured Value = 11.757907 (C, atm, Hz, ...) 11:18:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.88 P3 = Bottom Coil, Value = 27.63 P4 = Top Coil, Value = 28.24 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 30.53 P7 = Ambient, Value = 24.11 P8 = Supply Pres(psi), Value = 123.55 P9 = Return Pres(psi), Value = 11.76 11:19:53 Magnet Current for MAIN, Imag = 164.9759 A Vtrans = 1.649816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:19:54 MAIN (V) Voltage Measurement, V = 6.542222 V 11:19:58 Temperature Measurement, Probe Number = 0, T = 24.897000 C 11:19:58 Temperature Measurement, Probe Number = 1, T = 27.635000 C 11:19:59 Temperature Measurement, Probe Number = 2, T = 28.217000 C 11:19:59 Temperature Measurement, Probe Number = 3, T = 28.739000 C 11:20:00 Temperature Measurement, Probe Number = 4, T = 30.555000 C 11:20:01 Temperature Measurement, Probe Number = 5, T = 24.085000 C 11:20:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667724 V 11:20:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667724 (V, A, ohm, ...), Measured Value = 125.079292 (C, atm, Hz, ...) 11:20:02 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158429 V 11:20:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158429 (V, A, ohm, ...), Measured Value = 11.882182 (C, atm, Hz, ...) 11:20:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.90 P3 = Bottom Coil, Value = 27.64 P4 = Top Coil, Value = 28.22 P5 = Water In, Value = 28.74 P6 = Water Out, Value = 30.55 P7 = Ambient, Value = 24.09 P8 = Supply Pres(psi), Value = 125.08 P9 = Return Pres(psi), Value = 11.88 11:21:03 Magnet Current for MAIN, Imag = 164.9763 A Vtrans = 1.649820 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:21:03 MAIN (V) Voltage Measurement, V = 6.542301 V 11:21:07 Temperature Measurement, Probe Number = 0, T = 24.911000 C 11:21:07 Temperature Measurement, Probe Number = 1, T = 27.623000 C 11:21:08 Temperature Measurement, Probe Number = 2, T = 28.074000 C 11:21:08 Temperature Measurement, Probe Number = 3, T = 28.754000 C 11:21:09 Temperature Measurement, Probe Number = 4, T = 30.585000 C 11:21:10 Temperature Measurement, Probe Number = 5, T = 24.106000 C 11:21:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.655150 V 11:21:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.655150 (V, A, ohm, ...), Measured Value = 124.136235 (C, atm, Hz, ...) 11:21:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155772 V 11:21:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155772 (V, A, ohm, ...), Measured Value = 11.682892 (C, atm, Hz, ...) 11:21:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.91 P3 = Bottom Coil, Value = 27.62 P4 = Top Coil, Value = 28.07 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.11 P8 = Supply Pres(psi), Value = 124.14 P9 = Return Pres(psi), Value = 11.68 11:22:12 Magnet Current for MAIN, Imag = 164.9769 A Vtrans = 1.649826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:22:12 MAIN (V) Voltage Measurement, V = 6.542334 V 11:22:16 Temperature Measurement, Probe Number = 0, T = 24.930000 C 11:22:16 Temperature Measurement, Probe Number = 1, T = 27.709000 C 11:22:17 Temperature Measurement, Probe Number = 2, T = 28.209000 C 11:22:17 Temperature Measurement, Probe Number = 3, T = 28.715000 C 11:22:18 Temperature Measurement, Probe Number = 4, T = 30.604000 C 11:22:19 Temperature Measurement, Probe Number = 5, T = 24.091000 C 11:22:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.638332 V 11:22:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.638332 (V, A, ohm, ...), Measured Value = 122.874863 (C, atm, Hz, ...) 11:22:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156062 V 11:22:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156062 (V, A, ohm, ...), Measured Value = 11.704620 (C, atm, Hz, ...) 11:22:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.93 P3 = Bottom Coil, Value = 27.71 P4 = Top Coil, Value = 28.21 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 30.60 P7 = Ambient, Value = 24.09 P8 = Supply Pres(psi), Value = 122.87 P9 = Return Pres(psi), Value = 11.70 11:23:21 Magnet Current for MAIN, Imag = 164.9767 A Vtrans = 1.649824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:23:21 MAIN (V) Voltage Measurement, V = 6.542416 V 11:23:25 Temperature Measurement, Probe Number = 0, T = 24.956000 C 11:23:25 Temperature Measurement, Probe Number = 1, T = 27.675000 C 11:23:26 Temperature Measurement, Probe Number = 2, T = 28.108000 C 11:23:26 Temperature Measurement, Probe Number = 3, T = 28.738000 C 11:23:27 Temperature Measurement, Probe Number = 4, T = 30.606000 C 11:23:28 Temperature Measurement, Probe Number = 5, T = 24.120000 C 11:23:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.670125 V 11:23:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670125 (V, A, ohm, ...), Measured Value = 125.259382 (C, atm, Hz, ...) 11:23:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155823 V 11:23:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155823 (V, A, ohm, ...), Measured Value = 11.686733 (C, atm, Hz, ...) 11:23:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.96 P3 = Bottom Coil, Value = 27.68 P4 = Top Coil, Value = 28.11 P5 = Water In, Value = 28.74 P6 = Water Out, Value = 30.61 P7 = Ambient, Value = 24.12 P8 = Supply Pres(psi), Value = 125.26 P9 = Return Pres(psi), Value = 11.69 11:24:29 Magnet Current for MAIN, Imag = 164.9768 A Vtrans = 1.649825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:24:30 MAIN (V) Voltage Measurement, V = 6.542284 V 11:24:34 Temperature Measurement, Probe Number = 0, T = 24.980000 C 11:24:34 Temperature Measurement, Probe Number = 1, T = 27.653000 C 11:24:35 Temperature Measurement, Probe Number = 2, T = 28.216000 C 11:24:35 Temperature Measurement, Probe Number = 3, T = 28.762000 C 11:24:36 Temperature Measurement, Probe Number = 4, T = 30.590000 C 11:24:37 Temperature Measurement, Probe Number = 5, T = 24.151000 C 11:24:37 Sensor Voltage Measurement, Sensor Number = 0, V = 2.649984 V 11:24:37 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649984 (V, A, ohm, ...), Measured Value = 123.748808 (C, atm, Hz, ...) 11:24:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155806 V 11:24:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155806 (V, A, ohm, ...), Measured Value = 11.685420 (C, atm, Hz, ...) 11:24:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 24.98 P3 = Bottom Coil, Value = 27.65 P4 = Top Coil, Value = 28.22 P5 = Water In, Value = 28.76 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.15 P8 = Supply Pres(psi), Value = 123.75 P9 = Return Pres(psi), Value = 11.69 11:25:39 Magnet Current for MAIN, Imag = 164.9768 A Vtrans = 1.649825 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:25:39 MAIN (V) Voltage Measurement, V = 6.542263 V 11:25:43 Temperature Measurement, Probe Number = 0, T = 24.999000 C 11:25:43 Temperature Measurement, Probe Number = 1, T = 27.639000 C 11:25:44 Temperature Measurement, Probe Number = 2, T = 28.181000 C 11:25:44 Temperature Measurement, Probe Number = 3, T = 28.773000 C 11:25:45 Temperature Measurement, Probe Number = 4, T = 30.594000 C 11:25:46 Temperature Measurement, Probe Number = 5, T = 24.117000 C 11:25:46 Sensor Voltage Measurement, Sensor Number = 0, V = 2.643211 V 11:25:46 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.643211 (V, A, ohm, ...), Measured Value = 123.240848 (C, atm, Hz, ...) 11:25:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157956 V 11:25:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157956 (V, A, ohm, ...), Measured Value = 11.846685 (C, atm, Hz, ...) 11:25:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.00 P3 = Bottom Coil, Value = 27.64 P4 = Top Coil, Value = 28.18 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.12 P8 = Supply Pres(psi), Value = 123.24 P9 = Return Pres(psi), Value = 11.85 11:26:48 Magnet Current for MAIN, Imag = 164.9767 A Vtrans = 1.649824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:26:48 MAIN (V) Voltage Measurement, V = 6.542408 V 11:26:52 Temperature Measurement, Probe Number = 0, T = 25.000000 C 11:26:52 Temperature Measurement, Probe Number = 1, T = 27.667000 C 11:26:53 Temperature Measurement, Probe Number = 2, T = 28.239000 C 11:26:53 Temperature Measurement, Probe Number = 3, T = 28.774000 C 11:26:54 Temperature Measurement, Probe Number = 4, T = 30.590000 C 11:26:55 Temperature Measurement, Probe Number = 5, T = 24.177000 C 11:26:55 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663046 V 11:26:55 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663046 (V, A, ohm, ...), Measured Value = 124.728480 (C, atm, Hz, ...) 11:26:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157182 V 11:26:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157182 (V, A, ohm, ...), Measured Value = 11.788627 (C, atm, Hz, ...) 11:26:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.00 P3 = Bottom Coil, Value = 27.67 P4 = Top Coil, Value = 28.24 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.18 P8 = Supply Pres(psi), Value = 124.73 P9 = Return Pres(psi), Value = 11.79 11:27:57 Magnet Current for MAIN, Imag = 164.9774 A Vtrans = 1.649831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:27:57 MAIN (V) Voltage Measurement, V = 6.542806 V 11:28:01 Temperature Measurement, Probe Number = 0, T = 25.029000 C 11:28:01 Temperature Measurement, Probe Number = 1, T = 27.625000 C 11:28:02 Temperature Measurement, Probe Number = 2, T = 28.297000 C 11:28:03 Temperature Measurement, Probe Number = 3, T = 28.779000 C 11:28:03 Temperature Measurement, Probe Number = 4, T = 30.603000 C 11:28:04 Temperature Measurement, Probe Number = 5, T = 24.186000 C 11:28:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.669342 V 11:28:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669342 (V, A, ohm, ...), Measured Value = 125.200658 (C, atm, Hz, ...) 11:28:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157223 V 11:28:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157223 (V, A, ohm, ...), Measured Value = 11.791718 (C, atm, Hz, ...) 11:28:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.03 P3 = Bottom Coil, Value = 27.62 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.60 P7 = Ambient, Value = 24.19 P8 = Supply Pres(psi), Value = 125.20 P9 = Return Pres(psi), Value = 11.79 11:29:06 Magnet Current for MAIN, Imag = 164.9774 A Vtrans = 1.649831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:29:06 MAIN (V) Voltage Measurement, V = 6.543498 V 11:29:10 Temperature Measurement, Probe Number = 0, T = 25.051000 C 11:29:10 Temperature Measurement, Probe Number = 1, T = 27.623000 C 11:29:11 Temperature Measurement, Probe Number = 2, T = 28.190000 C 11:29:12 Temperature Measurement, Probe Number = 3, T = 28.789000 C 11:29:12 Temperature Measurement, Probe Number = 4, T = 30.629000 C 11:29:13 Temperature Measurement, Probe Number = 5, T = 24.240000 C 11:29:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.652109 V 11:29:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652109 (V, A, ohm, ...), Measured Value = 123.908197 (C, atm, Hz, ...) 11:29:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156701 V 11:29:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156701 (V, A, ohm, ...), Measured Value = 11.752567 (C, atm, Hz, ...) 11:29:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.05 P3 = Bottom Coil, Value = 27.62 P4 = Top Coil, Value = 28.19 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 30.63 P7 = Ambient, Value = 24.24 P8 = Supply Pres(psi), Value = 123.91 P9 = Return Pres(psi), Value = 11.75 11:30:15 Magnet Current for MAIN, Imag = 164.9777 A Vtrans = 1.649834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:30:15 MAIN (V) Voltage Measurement, V = 6.543854 V 11:30:19 Temperature Measurement, Probe Number = 0, T = 25.064000 C 11:30:19 Temperature Measurement, Probe Number = 1, T = 27.768000 C 11:30:20 Temperature Measurement, Probe Number = 2, T = 28.168000 C 11:30:21 Temperature Measurement, Probe Number = 3, T = 28.789000 C 11:30:21 Temperature Measurement, Probe Number = 4, T = 30.648000 C 11:30:22 Temperature Measurement, Probe Number = 5, T = 24.237000 C 11:30:22 Sensor Voltage Measurement, Sensor Number = 0, V = 2.651686 V 11:30:22 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.651686 (V, A, ohm, ...), Measured Value = 123.876450 (C, atm, Hz, ...) 11:30:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155076 V 11:30:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155076 (V, A, ohm, ...), Measured Value = 11.630730 (C, atm, Hz, ...) 11:30:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.06 P3 = Bottom Coil, Value = 27.77 P4 = Top Coil, Value = 28.17 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.24 P8 = Supply Pres(psi), Value = 123.88 P9 = Return Pres(psi), Value = 11.63 11:31:24 Magnet Current for MAIN, Imag = 164.9777 A Vtrans = 1.649834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:31:24 MAIN (V) Voltage Measurement, V = 6.543791 V 11:31:28 Temperature Measurement, Probe Number = 0, T = 25.043000 C 11:31:28 Temperature Measurement, Probe Number = 1, T = 27.745000 C 11:31:29 Temperature Measurement, Probe Number = 2, T = 28.161000 C 11:31:30 Temperature Measurement, Probe Number = 3, T = 28.777000 C 11:31:30 Temperature Measurement, Probe Number = 4, T = 30.668000 C 11:31:31 Temperature Measurement, Probe Number = 5, T = 24.234000 C 11:31:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.633303 V 11:31:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.633303 (V, A, ohm, ...), Measured Value = 122.497732 (C, atm, Hz, ...) 11:31:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156039 V 11:31:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156039 (V, A, ohm, ...), Measured Value = 11.702933 (C, atm, Hz, ...) 11:31:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.04 P3 = Bottom Coil, Value = 27.75 P4 = Top Coil, Value = 28.16 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.67 P7 = Ambient, Value = 24.23 P8 = Supply Pres(psi), Value = 122.50 P9 = Return Pres(psi), Value = 11.70 11:32:33 Magnet Current for MAIN, Imag = 164.9779 A Vtrans = 1.649836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:32:33 MAIN (V) Voltage Measurement, V = 6.543591 V 11:32:37 Temperature Measurement, Probe Number = 0, T = 25.051000 C 11:32:37 Temperature Measurement, Probe Number = 1, T = 27.704000 C 11:32:38 Temperature Measurement, Probe Number = 2, T = 28.184000 C 11:32:39 Temperature Measurement, Probe Number = 3, T = 28.787000 C 11:32:39 Temperature Measurement, Probe Number = 4, T = 30.670000 C 11:32:40 Temperature Measurement, Probe Number = 5, T = 24.257000 C 11:32:40 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662878 V 11:32:40 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662878 (V, A, ohm, ...), Measured Value = 124.715835 (C, atm, Hz, ...) 11:32:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156736 V 11:32:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156736 (V, A, ohm, ...), Measured Value = 11.755192 (C, atm, Hz, ...) 11:32:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.05 P3 = Bottom Coil, Value = 27.70 P4 = Top Coil, Value = 28.18 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 30.67 P7 = Ambient, Value = 24.26 P8 = Supply Pres(psi), Value = 124.72 P9 = Return Pres(psi), Value = 11.76 11:33:42 Magnet Current for MAIN, Imag = 164.9778 A Vtrans = 1.649835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:33:42 MAIN (V) Voltage Measurement, V = 6.543183 V 11:33:46 Temperature Measurement, Probe Number = 0, T = 25.092000 C 11:33:46 Temperature Measurement, Probe Number = 1, T = 27.657000 C 11:33:47 Temperature Measurement, Probe Number = 2, T = 28.270000 C 11:33:48 Temperature Measurement, Probe Number = 3, T = 28.780000 C 11:33:48 Temperature Measurement, Probe Number = 4, T = 30.653000 C 11:33:49 Temperature Measurement, Probe Number = 5, T = 24.271000 C 11:33:49 Sensor Voltage Measurement, Sensor Number = 0, V = 2.652128 V 11:33:49 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652128 (V, A, ohm, ...), Measured Value = 123.909600 (C, atm, Hz, ...) 11:33:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157003 V 11:33:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157003 (V, A, ohm, ...), Measured Value = 11.775233 (C, atm, Hz, ...) 11:33:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.09 P3 = Bottom Coil, Value = 27.66 P4 = Top Coil, Value = 28.27 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.27 P8 = Supply Pres(psi), Value = 123.91 P9 = Return Pres(psi), Value = 11.78 11:34:51 Magnet Current for MAIN, Imag = 164.9779 A Vtrans = 1.649836 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:34:51 MAIN (V) Voltage Measurement, V = 6.542931 V 11:34:55 Temperature Measurement, Probe Number = 0, T = 25.097000 C 11:34:55 Temperature Measurement, Probe Number = 1, T = 27.750000 C 11:34:56 Temperature Measurement, Probe Number = 2, T = 28.281000 C 11:34:57 Temperature Measurement, Probe Number = 3, T = 28.784000 C 11:34:57 Temperature Measurement, Probe Number = 4, T = 30.676000 C 11:34:58 Temperature Measurement, Probe Number = 5, T = 24.312000 C 11:34:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.654047 V 11:34:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654047 (V, A, ohm, ...), Measured Value = 124.053540 (C, atm, Hz, ...) 11:34:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156956 V 11:34:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156956 (V, A, ohm, ...), Measured Value = 11.771677 (C, atm, Hz, ...) 11:34:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.10 P3 = Bottom Coil, Value = 27.75 P4 = Top Coil, Value = 28.28 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.68 P7 = Ambient, Value = 24.31 P8 = Supply Pres(psi), Value = 124.05 P9 = Return Pres(psi), Value = 11.77 11:36:00 Magnet Current for MAIN, Imag = 164.9774 A Vtrans = 1.649831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:36:00 MAIN (V) Voltage Measurement, V = 6.542840 V 11:36:04 Temperature Measurement, Probe Number = 0, T = 25.120000 C 11:36:04 Temperature Measurement, Probe Number = 1, T = 27.796000 C 11:36:05 Temperature Measurement, Probe Number = 2, T = 28.380000 C 11:36:06 Temperature Measurement, Probe Number = 3, T = 28.735000 C 11:36:06 Temperature Measurement, Probe Number = 4, T = 30.655000 C 11:36:07 Temperature Measurement, Probe Number = 5, T = 24.322000 C 11:36:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.638007 V 11:36:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.638007 (V, A, ohm, ...), Measured Value = 122.850518 (C, atm, Hz, ...) 11:36:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156040 V 11:36:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156040 (V, A, ohm, ...), Measured Value = 11.703030 (C, atm, Hz, ...) 11:36:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.12 P3 = Bottom Coil, Value = 27.80 P4 = Top Coil, Value = 28.38 P5 = Water In, Value = 28.73 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.32 P8 = Supply Pres(psi), Value = 122.85 P9 = Return Pres(psi), Value = 11.70 11:37:09 Magnet Current for MAIN, Imag = 164.9783 A Vtrans = 1.649840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:37:09 MAIN (V) Voltage Measurement, V = 6.543017 V 11:37:13 Temperature Measurement, Probe Number = 0, T = 25.142000 C 11:37:13 Temperature Measurement, Probe Number = 1, T = 27.778000 C 11:37:14 Temperature Measurement, Probe Number = 2, T = 28.304000 C 11:37:15 Temperature Measurement, Probe Number = 3, T = 28.702000 C 11:37:15 Temperature Measurement, Probe Number = 4, T = 30.647000 C 11:37:16 Temperature Measurement, Probe Number = 5, T = 24.347000 C 11:37:16 Sensor Voltage Measurement, Sensor Number = 0, V = 2.636143 V 11:37:16 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.636143 (V, A, ohm, ...), Measured Value = 122.710695 (C, atm, Hz, ...) 11:37:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156441 V 11:37:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156441 (V, A, ohm, ...), Measured Value = 11.733090 (C, atm, Hz, ...) 11:37:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.14 P3 = Bottom Coil, Value = 27.78 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.70 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.35 P8 = Supply Pres(psi), Value = 122.71 P9 = Return Pres(psi), Value = 11.73 11:38:18 Magnet Current for MAIN, Imag = 164.9784 A Vtrans = 1.649841 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:38:18 MAIN (V) Voltage Measurement, V = 6.543504 V 11:38:22 Temperature Measurement, Probe Number = 0, T = 25.141000 C 11:38:22 Temperature Measurement, Probe Number = 1, T = 27.782000 C 11:38:23 Temperature Measurement, Probe Number = 2, T = 28.319000 C 11:38:24 Temperature Measurement, Probe Number = 3, T = 28.755000 C 11:38:24 Temperature Measurement, Probe Number = 4, T = 30.664000 C 11:38:25 Temperature Measurement, Probe Number = 5, T = 24.378000 C 11:38:25 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666267 V 11:38:25 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666267 (V, A, ohm, ...), Measured Value = 124.970002 (C, atm, Hz, ...) 11:38:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157453 V 11:38:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157453 (V, A, ohm, ...), Measured Value = 11.808945 (C, atm, Hz, ...) 11:38:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.14 P3 = Bottom Coil, Value = 27.78 P4 = Top Coil, Value = 28.32 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.38 P8 = Supply Pres(psi), Value = 124.97 P9 = Return Pres(psi), Value = 11.81 11:39:27 Magnet Current for MAIN, Imag = 164.9783 A Vtrans = 1.649840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:39:27 MAIN (V) Voltage Measurement, V = 6.543566 V 11:39:31 Temperature Measurement, Probe Number = 0, T = 25.160000 C 11:39:31 Temperature Measurement, Probe Number = 1, T = 27.743000 C 11:39:32 Temperature Measurement, Probe Number = 2, T = 28.250000 C 11:39:33 Temperature Measurement, Probe Number = 3, T = 28.749000 C 11:39:33 Temperature Measurement, Probe Number = 4, T = 30.644000 C 11:39:34 Temperature Measurement, Probe Number = 5, T = 24.377000 C 11:39:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.674017 V 11:39:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.674017 (V, A, ohm, ...), Measured Value = 125.551290 (C, atm, Hz, ...) 11:39:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158404 V 11:39:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158404 (V, A, ohm, ...), Measured Value = 11.880308 (C, atm, Hz, ...) 11:39:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.16 P3 = Bottom Coil, Value = 27.74 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.64 P7 = Ambient, Value = 24.38 P8 = Supply Pres(psi), Value = 125.55 P9 = Return Pres(psi), Value = 11.88 11:40:36 Magnet Current for MAIN, Imag = 164.9785 A Vtrans = 1.649843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:40:36 MAIN (V) Voltage Measurement, V = 6.543709 V 11:40:40 Temperature Measurement, Probe Number = 0, T = 25.166000 C 11:40:40 Temperature Measurement, Probe Number = 1, T = 27.722000 C 11:40:41 Temperature Measurement, Probe Number = 2, T = 28.223000 C 11:40:42 Temperature Measurement, Probe Number = 3, T = 28.767000 C 11:40:42 Temperature Measurement, Probe Number = 4, T = 30.672000 C 11:40:43 Temperature Measurement, Probe Number = 5, T = 24.383000 C 11:40:43 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656653 V 11:40:43 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656653 (V, A, ohm, ...), Measured Value = 124.248990 (C, atm, Hz, ...) 11:40:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157503 V 11:40:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157503 (V, A, ohm, ...), Measured Value = 11.812695 (C, atm, Hz, ...) 11:40:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.17 P3 = Bottom Coil, Value = 27.72 P4 = Top Coil, Value = 28.22 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.67 P7 = Ambient, Value = 24.38 P8 = Supply Pres(psi), Value = 124.25 P9 = Return Pres(psi), Value = 11.81 11:41:45 Magnet Current for MAIN, Imag = 164.9783 A Vtrans = 1.649840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:41:45 MAIN (V) Voltage Measurement, V = 6.543629 V 11:41:49 Temperature Measurement, Probe Number = 0, T = 25.184000 C 11:41:49 Temperature Measurement, Probe Number = 1, T = 27.742000 C 11:41:50 Temperature Measurement, Probe Number = 2, T = 28.227000 C 11:41:51 Temperature Measurement, Probe Number = 3, T = 28.751000 C 11:41:51 Temperature Measurement, Probe Number = 4, T = 30.659000 C 11:41:52 Temperature Measurement, Probe Number = 5, T = 24.365000 C 11:41:52 Sensor Voltage Measurement, Sensor Number = 0, V = 2.646839 V 11:41:52 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.646839 (V, A, ohm, ...), Measured Value = 123.512902 (C, atm, Hz, ...) 11:41:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155711 V 11:41:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155711 (V, A, ohm, ...), Measured Value = 11.678302 (C, atm, Hz, ...) 11:41:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.18 P3 = Bottom Coil, Value = 27.74 P4 = Top Coil, Value = 28.23 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.36 P8 = Supply Pres(psi), Value = 123.51 P9 = Return Pres(psi), Value = 11.68 11:42:54 Magnet Current for MAIN, Imag = 164.9783 A Vtrans = 1.649840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:42:54 MAIN (V) Voltage Measurement, V = 6.543620 V 11:42:58 Temperature Measurement, Probe Number = 0, T = 25.186000 C 11:42:59 Temperature Measurement, Probe Number = 1, T = 27.810000 C 11:42:59 Temperature Measurement, Probe Number = 2, T = 28.122000 C 11:43:00 Temperature Measurement, Probe Number = 3, T = 28.776000 C 11:43:00 Temperature Measurement, Probe Number = 4, T = 30.654000 C 11:43:01 Temperature Measurement, Probe Number = 5, T = 24.417000 C 11:43:01 Sensor Voltage Measurement, Sensor Number = 0, V = 2.648868 V 11:43:01 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648868 (V, A, ohm, ...), Measured Value = 123.665085 (C, atm, Hz, ...) 11:43:02 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154488 V 11:43:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154488 (V, A, ohm, ...), Measured Value = 11.586622 (C, atm, Hz, ...) 11:43:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.19 P3 = Bottom Coil, Value = 27.81 P4 = Top Coil, Value = 28.12 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.42 P8 = Supply Pres(psi), Value = 123.67 P9 = Return Pres(psi), Value = 11.59 11:44:03 Magnet Current for MAIN, Imag = 164.9783 A Vtrans = 1.649840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:44:03 MAIN (V) Voltage Measurement, V = 6.543598 V 11:44:07 Temperature Measurement, Probe Number = 0, T = 25.217000 C 11:44:08 Temperature Measurement, Probe Number = 1, T = 27.878000 C 11:44:08 Temperature Measurement, Probe Number = 2, T = 28.337000 C 11:44:09 Temperature Measurement, Probe Number = 3, T = 28.730000 C 11:44:09 Temperature Measurement, Probe Number = 4, T = 30.652000 C 11:44:10 Temperature Measurement, Probe Number = 5, T = 24.428000 C 11:44:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.644094 V 11:44:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644094 (V, A, ohm, ...), Measured Value = 123.307057 (C, atm, Hz, ...) 11:44:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156499 V 11:44:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156499 (V, A, ohm, ...), Measured Value = 11.737395 (C, atm, Hz, ...) 11:44:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.22 P3 = Bottom Coil, Value = 27.88 P4 = Top Coil, Value = 28.34 P5 = Water In, Value = 28.73 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.43 P8 = Supply Pres(psi), Value = 123.31 P9 = Return Pres(psi), Value = 11.74 11:45:12 Magnet Current for MAIN, Imag = 164.9788 A Vtrans = 1.649845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:45:12 MAIN (V) Voltage Measurement, V = 6.543573 V 11:45:16 Temperature Measurement, Probe Number = 0, T = 25.237000 C 11:45:17 Temperature Measurement, Probe Number = 1, T = 27.833000 C 11:45:17 Temperature Measurement, Probe Number = 2, T = 28.266000 C 11:45:18 Temperature Measurement, Probe Number = 3, T = 28.766000 C 11:45:18 Temperature Measurement, Probe Number = 4, T = 30.680000 C 11:45:19 Temperature Measurement, Probe Number = 5, T = 24.418000 C 11:45:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.671496 V 11:45:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.671496 (V, A, ohm, ...), Measured Value = 125.362208 (C, atm, Hz, ...) 11:45:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156888 V 11:45:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156888 (V, A, ohm, ...), Measured Value = 11.766615 (C, atm, Hz, ...) 11:45:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.24 P3 = Bottom Coil, Value = 27.83 P4 = Top Coil, Value = 28.27 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.68 P7 = Ambient, Value = 24.42 P8 = Supply Pres(psi), Value = 125.36 P9 = Return Pres(psi), Value = 11.77 11:46:21 Magnet Current for MAIN, Imag = 164.9787 A Vtrans = 1.649844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:46:21 MAIN (V) Voltage Measurement, V = 6.543553 V 11:46:25 Temperature Measurement, Probe Number = 0, T = 25.245000 C 11:46:26 Temperature Measurement, Probe Number = 1, T = 27.834000 C 11:46:26 Temperature Measurement, Probe Number = 2, T = 28.351000 C 11:46:27 Temperature Measurement, Probe Number = 3, T = 28.777000 C 11:46:27 Temperature Measurement, Probe Number = 4, T = 30.691000 C 11:46:28 Temperature Measurement, Probe Number = 5, T = 24.465000 C 11:46:28 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667559 V 11:46:28 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667559 (V, A, ohm, ...), Measured Value = 125.066933 (C, atm, Hz, ...) 11:46:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157109 V 11:46:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157109 (V, A, ohm, ...), Measured Value = 11.783190 (C, atm, Hz, ...) 11:46:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.25 P3 = Bottom Coil, Value = 27.83 P4 = Top Coil, Value = 28.35 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.69 P7 = Ambient, Value = 24.46 P8 = Supply Pres(psi), Value = 125.07 P9 = Return Pres(psi), Value = 11.78 11:47:30 Magnet Current for MAIN, Imag = 164.9790 A Vtrans = 1.649848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:47:30 MAIN (V) Voltage Measurement, V = 6.543571 V 11:47:34 Temperature Measurement, Probe Number = 0, T = 25.252000 C 11:47:35 Temperature Measurement, Probe Number = 1, T = 27.818000 C 11:47:35 Temperature Measurement, Probe Number = 2, T = 28.300000 C 11:47:36 Temperature Measurement, Probe Number = 3, T = 28.771000 C 11:47:36 Temperature Measurement, Probe Number = 4, T = 30.685000 C 11:47:37 Temperature Measurement, Probe Number = 5, T = 24.435000 C 11:47:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662070 V 11:47:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662070 (V, A, ohm, ...), Measured Value = 124.655243 (C, atm, Hz, ...) 11:47:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157203 V 11:47:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157203 (V, A, ohm, ...), Measured Value = 11.790217 (C, atm, Hz, ...) 11:47:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.25 P3 = Bottom Coil, Value = 27.82 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.68 P7 = Ambient, Value = 24.43 P8 = Supply Pres(psi), Value = 124.66 P9 = Return Pres(psi), Value = 11.79 11:48:39 Magnet Current for MAIN, Imag = 164.9788 A Vtrans = 1.649845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:48:39 MAIN (V) Voltage Measurement, V = 6.543388 V 11:48:43 Temperature Measurement, Probe Number = 0, T = 25.246000 C 11:48:44 Temperature Measurement, Probe Number = 1, T = 27.835000 C 11:48:44 Temperature Measurement, Probe Number = 2, T = 28.254000 C 11:48:45 Temperature Measurement, Probe Number = 3, T = 28.772000 C 11:48:45 Temperature Measurement, Probe Number = 4, T = 30.690000 C 11:48:46 Temperature Measurement, Probe Number = 5, T = 24.456000 C 11:48:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663321 V 11:48:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663321 (V, A, ohm, ...), Measured Value = 124.749083 (C, atm, Hz, ...) 11:48:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158339 V 11:48:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158339 (V, A, ohm, ...), Measured Value = 11.875440 (C, atm, Hz, ...) 11:48:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.25 P3 = Bottom Coil, Value = 27.84 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 30.69 P7 = Ambient, Value = 24.46 P8 = Supply Pres(psi), Value = 124.75 P9 = Return Pres(psi), Value = 11.88 11:49:48 Magnet Current for MAIN, Imag = 164.9788 A Vtrans = 1.649845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:49:48 MAIN (V) Voltage Measurement, V = 6.543382 V 11:49:52 Temperature Measurement, Probe Number = 0, T = 25.215000 C 11:49:53 Temperature Measurement, Probe Number = 1, T = 27.829000 C 11:49:53 Temperature Measurement, Probe Number = 2, T = 28.303000 C 11:49:54 Temperature Measurement, Probe Number = 3, T = 28.788000 C 11:49:54 Temperature Measurement, Probe Number = 4, T = 30.688000 C 11:49:55 Temperature Measurement, Probe Number = 5, T = 24.485000 C 11:49:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.634728 V 11:49:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.634728 (V, A, ohm, ...), Measured Value = 122.604593 (C, atm, Hz, ...) 11:49:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154917 V 11:49:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154917 (V, A, ohm, ...), Measured Value = 11.618745 (C, atm, Hz, ...) 11:49:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.21 P3 = Bottom Coil, Value = 27.83 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 30.69 P7 = Ambient, Value = 24.48 P8 = Supply Pres(psi), Value = 122.60 P9 = Return Pres(psi), Value = 11.62 11:50:57 Magnet Current for MAIN, Imag = 164.9793 A Vtrans = 1.649850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:50:57 MAIN (V) Voltage Measurement, V = 6.543538 V 11:51:01 Temperature Measurement, Probe Number = 0, T = 25.234000 C 11:51:02 Temperature Measurement, Probe Number = 1, T = 27.857000 C 11:51:02 Temperature Measurement, Probe Number = 2, T = 28.365000 C 11:51:03 Temperature Measurement, Probe Number = 3, T = 28.804000 C 11:51:03 Temperature Measurement, Probe Number = 4, T = 30.662000 C 11:51:04 Temperature Measurement, Probe Number = 5, T = 24.472000 C 11:51:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.645299 V 11:51:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645299 (V, A, ohm, ...), Measured Value = 123.397432 (C, atm, Hz, ...) 11:51:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157721 V 11:51:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157721 (V, A, ohm, ...), Measured Value = 11.829083 (C, atm, Hz, ...) 11:51:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.23 P3 = Bottom Coil, Value = 27.86 P4 = Top Coil, Value = 28.36 P5 = Water In, Value = 28.80 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.47 P8 = Supply Pres(psi), Value = 123.40 P9 = Return Pres(psi), Value = 11.83 11:52:06 Magnet Current for MAIN, Imag = 164.9789 A Vtrans = 1.649846 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:52:06 MAIN (V) Voltage Measurement, V = 6.543855 V 11:52:10 Temperature Measurement, Probe Number = 0, T = 25.287000 C 11:52:11 Temperature Measurement, Probe Number = 1, T = 27.847000 C 11:52:11 Temperature Measurement, Probe Number = 2, T = 28.458000 C 11:52:12 Temperature Measurement, Probe Number = 3, T = 28.784000 C 11:52:12 Temperature Measurement, Probe Number = 4, T = 30.647000 C 11:52:13 Temperature Measurement, Probe Number = 5, T = 24.518000 C 11:52:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.630007 V 11:52:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.630007 (V, A, ohm, ...), Measured Value = 122.250502 (C, atm, Hz, ...) 11:52:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155975 V 11:52:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155975 (V, A, ohm, ...), Measured Value = 11.698155 (C, atm, Hz, ...) 11:52:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.29 P3 = Bottom Coil, Value = 27.85 P4 = Top Coil, Value = 28.46 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.65 P7 = Ambient, Value = 24.52 P8 = Supply Pres(psi), Value = 122.25 P9 = Return Pres(psi), Value = 11.70 11:53:15 Magnet Current for MAIN, Imag = 164.9795 A Vtrans = 1.649853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:53:15 MAIN (V) Voltage Measurement, V = 6.544005 V 11:53:19 Temperature Measurement, Probe Number = 0, T = 25.314000 C 11:53:20 Temperature Measurement, Probe Number = 1, T = 27.873000 C 11:53:20 Temperature Measurement, Probe Number = 2, T = 28.401000 C 11:53:21 Temperature Measurement, Probe Number = 3, T = 28.786000 C 11:53:21 Temperature Measurement, Probe Number = 4, T = 30.686000 C 11:53:22 Temperature Measurement, Probe Number = 5, T = 24.542000 C 11:53:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.636362 V 11:53:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.636362 (V, A, ohm, ...), Measured Value = 122.727180 (C, atm, Hz, ...) 11:53:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157865 V 11:53:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157865 (V, A, ohm, ...), Measured Value = 11.839852 (C, atm, Hz, ...) 11:53:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.31 P3 = Bottom Coil, Value = 27.87 P4 = Top Coil, Value = 28.40 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 30.69 P7 = Ambient, Value = 24.54 P8 = Supply Pres(psi), Value = 122.73 P9 = Return Pres(psi), Value = 11.84 11:54:24 Magnet Current for MAIN, Imag = 164.9793 A Vtrans = 1.649850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:54:24 MAIN (V) Voltage Measurement, V = 6.544093 V 11:54:28 Temperature Measurement, Probe Number = 0, T = 25.331000 C 11:54:29 Temperature Measurement, Probe Number = 1, T = 27.911000 C 11:54:29 Temperature Measurement, Probe Number = 2, T = 28.484000 C 11:54:30 Temperature Measurement, Probe Number = 3, T = 28.799000 C 11:54:30 Temperature Measurement, Probe Number = 4, T = 30.703000 C 11:54:31 Temperature Measurement, Probe Number = 5, T = 24.555000 C 11:54:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659712 V 11:54:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659712 (V, A, ohm, ...), Measured Value = 124.478430 (C, atm, Hz, ...) 11:54:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158394 V 11:54:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158394 (V, A, ohm, ...), Measured Value = 11.879557 (C, atm, Hz, ...) 11:54:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.33 P3 = Bottom Coil, Value = 27.91 P4 = Top Coil, Value = 28.48 P5 = Water In, Value = 28.80 P6 = Water Out, Value = 30.70 P7 = Ambient, Value = 24.55 P8 = Supply Pres(psi), Value = 124.48 P9 = Return Pres(psi), Value = 11.88 11:55:33 Magnet Current for MAIN, Imag = 164.9790 A Vtrans = 1.649848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:55:33 MAIN (V) Voltage Measurement, V = 6.544535 V 11:55:37 Temperature Measurement, Probe Number = 0, T = 25.344000 C 11:55:38 Temperature Measurement, Probe Number = 1, T = 27.898000 C 11:55:38 Temperature Measurement, Probe Number = 2, T = 28.361000 C 11:55:39 Temperature Measurement, Probe Number = 3, T = 28.811000 C 11:55:39 Temperature Measurement, Probe Number = 4, T = 30.716000 C 11:55:40 Temperature Measurement, Probe Number = 5, T = 24.513000 C 11:55:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.649875 V 11:55:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.649875 (V, A, ohm, ...), Measured Value = 123.740655 (C, atm, Hz, ...) 11:55:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.159048 V 11:55:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.159048 (V, A, ohm, ...), Measured Value = 11.928630 (C, atm, Hz, ...) 11:55:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.34 P3 = Bottom Coil, Value = 27.90 P4 = Top Coil, Value = 28.36 P5 = Water In, Value = 28.81 P6 = Water Out, Value = 30.72 P7 = Ambient, Value = 24.51 P8 = Supply Pres(psi), Value = 123.74 P9 = Return Pres(psi), Value = 11.93 11:56:42 Magnet Current for MAIN, Imag = 164.9789 A Vtrans = 1.649846 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:56:42 MAIN (V) Voltage Measurement, V = 6.544604 V 11:56:46 Temperature Measurement, Probe Number = 0, T = 25.333000 C 11:56:47 Temperature Measurement, Probe Number = 1, T = 27.899000 C 11:56:47 Temperature Measurement, Probe Number = 2, T = 28.388000 C 11:56:48 Temperature Measurement, Probe Number = 3, T = 28.839000 C 11:56:48 Temperature Measurement, Probe Number = 4, T = 30.714000 C 11:56:49 Temperature Measurement, Probe Number = 5, T = 24.545000 C 11:56:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.664690 V 11:56:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664690 (V, A, ohm, ...), Measured Value = 124.851720 (C, atm, Hz, ...) 11:56:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157219 V 11:56:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157219 (V, A, ohm, ...), Measured Value = 11.791433 (C, atm, Hz, ...) 11:56:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.33 P3 = Bottom Coil, Value = 27.90 P4 = Top Coil, Value = 28.39 P5 = Water In, Value = 28.84 P6 = Water Out, Value = 30.71 P7 = Ambient, Value = 24.55 P8 = Supply Pres(psi), Value = 124.85 P9 = Return Pres(psi), Value = 11.79 11:57:51 Magnet Current for MAIN, Imag = 164.9797 A Vtrans = 1.649854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:57:52 MAIN (V) Voltage Measurement, V = 6.544996 V 11:57:55 Temperature Measurement, Probe Number = 0, T = 25.345000 C 11:57:56 Temperature Measurement, Probe Number = 1, T = 27.920000 C 11:57:56 Temperature Measurement, Probe Number = 2, T = 28.443000 C 11:57:57 Temperature Measurement, Probe Number = 3, T = 28.827000 C 11:57:57 Temperature Measurement, Probe Number = 4, T = 30.720000 C 11:57:58 Temperature Measurement, Probe Number = 5, T = 24.493000 C 11:57:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666734 V 11:57:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666734 (V, A, ohm, ...), Measured Value = 125.005027 (C, atm, Hz, ...) 11:57:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158009 V 11:57:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158009 (V, A, ohm, ...), Measured Value = 11.850712 (C, atm, Hz, ...) 11:57:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.34 P3 = Bottom Coil, Value = 27.92 P4 = Top Coil, Value = 28.44 P5 = Water In, Value = 28.83 P6 = Water Out, Value = 30.72 P7 = Ambient, Value = 24.49 P8 = Supply Pres(psi), Value = 125.01 P9 = Return Pres(psi), Value = 11.85 11:59:00 Magnet Current for MAIN, Imag = 164.9794 A Vtrans = 1.649851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 11:59:00 MAIN (V) Voltage Measurement, V = 6.545901 V 11:59:04 Temperature Measurement, Probe Number = 0, T = 25.366000 C 11:59:05 Temperature Measurement, Probe Number = 1, T = 27.910000 C 11:59:05 Temperature Measurement, Probe Number = 2, T = 28.530000 C 11:59:06 Temperature Measurement, Probe Number = 3, T = 28.829000 C 11:59:06 Temperature Measurement, Probe Number = 4, T = 30.732000 C 11:59:07 Temperature Measurement, Probe Number = 5, T = 24.587000 C 11:59:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.644536 V 11:59:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.644536 (V, A, ohm, ...), Measured Value = 123.340207 (C, atm, Hz, ...) 11:59:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157627 V 11:59:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157627 (V, A, ohm, ...), Measured Value = 11.822055 (C, atm, Hz, ...) 11:59:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.37 P3 = Bottom Coil, Value = 27.91 P4 = Top Coil, Value = 28.53 P5 = Water In, Value = 28.83 P6 = Water Out, Value = 30.73 P7 = Ambient, Value = 24.59 P8 = Supply Pres(psi), Value = 123.34 P9 = Return Pres(psi), Value = 11.82 12:00:09 Magnet Current for MAIN, Imag = 164.9794 A Vtrans = 1.649851 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:00:09 MAIN (V) Voltage Measurement, V = 6.546732 V 12:00:13 Temperature Measurement, Probe Number = 0, T = 25.380000 C 12:00:14 Temperature Measurement, Probe Number = 1, T = 27.941000 C 12:00:14 Temperature Measurement, Probe Number = 2, T = 28.460000 C 12:00:15 Temperature Measurement, Probe Number = 3, T = 28.900000 C 12:00:15 Temperature Measurement, Probe Number = 4, T = 30.785000 C 12:00:16 Temperature Measurement, Probe Number = 5, T = 24.564000 C 12:00:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.672831 V 12:00:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.672831 (V, A, ohm, ...), Measured Value = 125.462318 (C, atm, Hz, ...) 12:00:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157796 V 12:00:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157796 (V, A, ohm, ...), Measured Value = 11.834700 (C, atm, Hz, ...) 12:00:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.38 P3 = Bottom Coil, Value = 27.94 P4 = Top Coil, Value = 28.46 P5 = Water In, Value = 28.90 P6 = Water Out, Value = 30.79 P7 = Ambient, Value = 24.56 P8 = Supply Pres(psi), Value = 125.46 P9 = Return Pres(psi), Value = 11.83 12:01:18 Magnet Current for MAIN, Imag = 164.9797 A Vtrans = 1.649854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:01:19 MAIN (V) Voltage Measurement, V = 6.547563 V 12:01:22 Temperature Measurement, Probe Number = 0, T = 25.405000 C 12:01:23 Temperature Measurement, Probe Number = 1, T = 27.923000 C 12:01:23 Temperature Measurement, Probe Number = 2, T = 28.490000 C 12:01:24 Temperature Measurement, Probe Number = 3, T = 28.901000 C 12:01:24 Temperature Measurement, Probe Number = 4, T = 30.816000 C 12:01:25 Temperature Measurement, Probe Number = 5, T = 24.615000 C 12:01:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663044 V 12:01:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663044 (V, A, ohm, ...), Measured Value = 124.728292 (C, atm, Hz, ...) 12:01:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156438 V 12:01:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156438 (V, A, ohm, ...), Measured Value = 11.732813 (C, atm, Hz, ...) 12:01:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.41 P3 = Bottom Coil, Value = 27.92 P4 = Top Coil, Value = 28.49 P5 = Water In, Value = 28.90 P6 = Water Out, Value = 30.82 P7 = Ambient, Value = 24.61 P8 = Supply Pres(psi), Value = 124.73 P9 = Return Pres(psi), Value = 11.73 12:02:27 Magnet Current for MAIN, Imag = 164.9798 A Vtrans = 1.649855 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:02:28 MAIN (V) Voltage Measurement, V = 6.547932 V 12:02:31 Temperature Measurement, Probe Number = 0, T = 25.410000 C 12:02:32 Temperature Measurement, Probe Number = 1, T = 27.925000 C 12:02:32 Temperature Measurement, Probe Number = 2, T = 28.550000 C 12:02:33 Temperature Measurement, Probe Number = 3, T = 28.938000 C 12:02:33 Temperature Measurement, Probe Number = 4, T = 30.826000 C 12:02:34 Temperature Measurement, Probe Number = 5, T = 24.601000 C 12:02:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.692150 V 12:02:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.692150 (V, A, ohm, ...), Measured Value = 126.911273 (C, atm, Hz, ...) 12:02:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157651 V 12:02:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157651 (V, A, ohm, ...), Measured Value = 11.823840 (C, atm, Hz, ...) 12:02:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.41 P3 = Bottom Coil, Value = 27.93 P4 = Top Coil, Value = 28.55 P5 = Water In, Value = 28.94 P6 = Water Out, Value = 30.83 P7 = Ambient, Value = 24.60 P8 = Supply Pres(psi), Value = 126.91 P9 = Return Pres(psi), Value = 11.82 12:03:36 Magnet Current for MAIN, Imag = 164.9800 A Vtrans = 1.649858 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:03:37 MAIN (V) Voltage Measurement, V = 6.547783 V 12:03:40 Temperature Measurement, Probe Number = 0, T = 25.432000 C 12:03:41 Temperature Measurement, Probe Number = 1, T = 27.948000 C 12:03:41 Temperature Measurement, Probe Number = 2, T = 28.540000 C 12:03:42 Temperature Measurement, Probe Number = 3, T = 28.962000 C 12:03:42 Temperature Measurement, Probe Number = 4, T = 30.786000 C 12:03:43 Temperature Measurement, Probe Number = 5, T = 24.585000 C 12:03:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.626557 V 12:03:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.626557 (V, A, ohm, ...), Measured Value = 121.991745 (C, atm, Hz, ...) 12:03:44 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156112 V 12:03:44 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156112 (V, A, ohm, ...), Measured Value = 11.708370 (C, atm, Hz, ...) 12:03:44 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.43 P3 = Bottom Coil, Value = 27.95 P4 = Top Coil, Value = 28.54 P5 = Water In, Value = 28.96 P6 = Water Out, Value = 30.79 P7 = Ambient, Value = 24.59 P8 = Supply Pres(psi), Value = 121.99 P9 = Return Pres(psi), Value = 11.71 12:04:45 Magnet Current for MAIN, Imag = 164.9798 A Vtrans = 1.649855 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:04:46 MAIN (V) Voltage Measurement, V = 6.547688 V 12:04:49 Temperature Measurement, Probe Number = 0, T = 25.453000 C 12:04:50 Temperature Measurement, Probe Number = 1, T = 27.968000 C 12:04:50 Temperature Measurement, Probe Number = 2, T = 28.586000 C 12:04:51 Temperature Measurement, Probe Number = 3, T = 28.963000 C 12:04:51 Temperature Measurement, Probe Number = 4, T = 30.809000 C 12:04:52 Temperature Measurement, Probe Number = 5, T = 24.642000 C 12:04:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.676659 V 12:04:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.676659 (V, A, ohm, ...), Measured Value = 125.749447 (C, atm, Hz, ...) 12:04:53 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157721 V 12:04:53 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157721 (V, A, ohm, ...), Measured Value = 11.829083 (C, atm, Hz, ...) 12:04:53 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.45 P3 = Bottom Coil, Value = 27.97 P4 = Top Coil, Value = 28.59 P5 = Water In, Value = 28.96 P6 = Water Out, Value = 30.81 P7 = Ambient, Value = 24.64 P8 = Supply Pres(psi), Value = 125.75 P9 = Return Pres(psi), Value = 11.83 12:05:54 Magnet Current for MAIN, Imag = 164.9799 A Vtrans = 1.649856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:05:55 MAIN (V) Voltage Measurement, V = 6.547713 V 12:05:58 Temperature Measurement, Probe Number = 0, T = 25.478000 C 12:05:59 Temperature Measurement, Probe Number = 1, T = 27.965000 C 12:05:59 Temperature Measurement, Probe Number = 2, T = 28.488000 C 12:06:00 Temperature Measurement, Probe Number = 3, T = 28.957000 C 12:06:01 Temperature Measurement, Probe Number = 4, T = 30.841000 C 12:06:01 Temperature Measurement, Probe Number = 5, T = 24.689000 C 12:06:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663987 V 12:06:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663987 (V, A, ohm, ...), Measured Value = 124.798995 (C, atm, Hz, ...) 12:06:02 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158337 V 12:06:02 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158337 (V, A, ohm, ...), Measured Value = 11.875253 (C, atm, Hz, ...) 12:06:02 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.48 P3 = Bottom Coil, Value = 27.96 P4 = Top Coil, Value = 28.49 P5 = Water In, Value = 28.96 P6 = Water Out, Value = 30.84 P7 = Ambient, Value = 24.69 P8 = Supply Pres(psi), Value = 124.80 P9 = Return Pres(psi), Value = 11.88 12:07:03 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:07:04 MAIN (V) Voltage Measurement, V = 6.547416 V 12:07:07 Temperature Measurement, Probe Number = 0, T = 25.479000 C 12:07:08 Temperature Measurement, Probe Number = 1, T = 27.989000 C 12:07:08 Temperature Measurement, Probe Number = 2, T = 28.533000 C 12:07:09 Temperature Measurement, Probe Number = 3, T = 28.922000 C 12:07:10 Temperature Measurement, Probe Number = 4, T = 30.852000 C 12:07:10 Temperature Measurement, Probe Number = 5, T = 24.696000 C 12:07:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.648463 V 12:07:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648463 (V, A, ohm, ...), Measured Value = 123.634740 (C, atm, Hz, ...) 12:07:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157149 V 12:07:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157149 (V, A, ohm, ...), Measured Value = 11.786190 (C, atm, Hz, ...) 12:07:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.48 P3 = Bottom Coil, Value = 27.99 P4 = Top Coil, Value = 28.53 P5 = Water In, Value = 28.92 P6 = Water Out, Value = 30.85 P7 = Ambient, Value = 24.70 P8 = Supply Pres(psi), Value = 123.63 P9 = Return Pres(psi), Value = 11.79 12:08:12 Magnet Current for MAIN, Imag = 164.9803 A Vtrans = 1.649860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:08:13 MAIN (V) Voltage Measurement, V = 6.547381 V 12:08:16 Temperature Measurement, Probe Number = 0, T = 25.480000 C 12:08:17 Temperature Measurement, Probe Number = 1, T = 28.012000 C 12:08:17 Temperature Measurement, Probe Number = 2, T = 28.510000 C 12:08:18 Temperature Measurement, Probe Number = 3, T = 28.928000 C 12:08:19 Temperature Measurement, Probe Number = 4, T = 30.847000 C 12:08:19 Temperature Measurement, Probe Number = 5, T = 24.668000 C 12:08:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.654553 V 12:08:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.654553 (V, A, ohm, ...), Measured Value = 124.091468 (C, atm, Hz, ...) 12:08:20 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158204 V 12:08:20 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158204 (V, A, ohm, ...), Measured Value = 11.865322 (C, atm, Hz, ...) 12:08:20 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.48 P3 = Bottom Coil, Value = 28.01 P4 = Top Coil, Value = 28.51 P5 = Water In, Value = 28.93 P6 = Water Out, Value = 30.85 P7 = Ambient, Value = 24.67 P8 = Supply Pres(psi), Value = 124.09 P9 = Return Pres(psi), Value = 11.87 12:09:21 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:09:22 MAIN (V) Voltage Measurement, V = 6.546971 V 12:09:25 Temperature Measurement, Probe Number = 0, T = 25.484000 C 12:09:26 Temperature Measurement, Probe Number = 1, T = 28.008000 C 12:09:26 Temperature Measurement, Probe Number = 2, T = 28.622000 C 12:09:27 Temperature Measurement, Probe Number = 3, T = 28.909000 C 12:09:28 Temperature Measurement, Probe Number = 4, T = 30.811000 C 12:09:28 Temperature Measurement, Probe Number = 5, T = 24.706000 C 12:09:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.669021 V 12:09:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669021 (V, A, ohm, ...), Measured Value = 125.176590 (C, atm, Hz, ...) 12:09:29 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157091 V 12:09:29 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157091 (V, A, ohm, ...), Measured Value = 11.781788 (C, atm, Hz, ...) 12:09:29 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.48 P3 = Bottom Coil, Value = 28.01 P4 = Top Coil, Value = 28.62 P5 = Water In, Value = 28.91 P6 = Water Out, Value = 30.81 P7 = Ambient, Value = 24.71 P8 = Supply Pres(psi), Value = 125.18 P9 = Return Pres(psi), Value = 11.78 12:10:30 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:10:31 MAIN (V) Voltage Measurement, V = 6.546485 V 12:10:34 Temperature Measurement, Probe Number = 0, T = 25.483000 C 12:10:35 Temperature Measurement, Probe Number = 1, T = 27.983000 C 12:10:35 Temperature Measurement, Probe Number = 2, T = 28.640000 C 12:10:36 Temperature Measurement, Probe Number = 3, T = 28.865000 C 12:10:37 Temperature Measurement, Probe Number = 4, T = 30.786000 C 12:10:37 Temperature Measurement, Probe Number = 5, T = 24.680000 C 12:10:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.660590 V 12:10:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660590 (V, A, ohm, ...), Measured Value = 124.544265 (C, atm, Hz, ...) 12:10:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157070 V 12:10:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157070 (V, A, ohm, ...), Measured Value = 11.780287 (C, atm, Hz, ...) 12:10:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.48 P3 = Bottom Coil, Value = 27.98 P4 = Top Coil, Value = 28.64 P5 = Water In, Value = 28.86 P6 = Water Out, Value = 30.79 P7 = Ambient, Value = 24.68 P8 = Supply Pres(psi), Value = 124.54 P9 = Return Pres(psi), Value = 11.78 12:11:39 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:11:40 MAIN (V) Voltage Measurement, V = 6.546076 V 12:11:43 Temperature Measurement, Probe Number = 0, T = 25.498000 C 12:11:44 Temperature Measurement, Probe Number = 1, T = 27.994000 C 12:11:44 Temperature Measurement, Probe Number = 2, T = 28.564000 C 12:11:45 Temperature Measurement, Probe Number = 3, T = 28.888000 C 12:11:46 Temperature Measurement, Probe Number = 4, T = 30.751000 C 12:11:46 Temperature Measurement, Probe Number = 5, T = 24.646000 C 12:11:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.660731 V 12:11:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.660731 (V, A, ohm, ...), Measured Value = 124.554848 (C, atm, Hz, ...) 12:11:47 Sensor Voltage Measurement, Sensor Number = 1, V = 1.159220 V 12:11:47 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.159220 (V, A, ohm, ...), Measured Value = 11.941463 (C, atm, Hz, ...) 12:11:47 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.50 P3 = Bottom Coil, Value = 27.99 P4 = Top Coil, Value = 28.56 P5 = Water In, Value = 28.89 P6 = Water Out, Value = 30.75 P7 = Ambient, Value = 24.65 P8 = Supply Pres(psi), Value = 124.55 P9 = Return Pres(psi), Value = 11.94 12:12:48 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:12:49 MAIN (V) Voltage Measurement, V = 6.546126 V 12:12:52 Temperature Measurement, Probe Number = 0, T = 25.495000 C 12:12:53 Temperature Measurement, Probe Number = 1, T = 28.012000 C 12:12:53 Temperature Measurement, Probe Number = 2, T = 28.548000 C 12:12:54 Temperature Measurement, Probe Number = 3, T = 28.886000 C 12:12:55 Temperature Measurement, Probe Number = 4, T = 30.726000 C 12:12:55 Temperature Measurement, Probe Number = 5, T = 24.698000 C 12:12:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.677111 V 12:12:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.677111 (V, A, ohm, ...), Measured Value = 125.783347 (C, atm, Hz, ...) 12:12:56 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157303 V 12:12:56 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157303 (V, A, ohm, ...), Measured Value = 11.797710 (C, atm, Hz, ...) 12:12:56 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.50 P3 = Bottom Coil, Value = 28.01 P4 = Top Coil, Value = 28.55 P5 = Water In, Value = 28.89 P6 = Water Out, Value = 30.73 P7 = Ambient, Value = 24.70 P8 = Supply Pres(psi), Value = 125.78 P9 = Return Pres(psi), Value = 11.80 12:13:57 Magnet Current for MAIN, Imag = 164.9804 A Vtrans = 1.649861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:13:58 MAIN (V) Voltage Measurement, V = 6.546147 V 12:14:01 Temperature Measurement, Probe Number = 0, T = 25.514000 C 12:14:02 Temperature Measurement, Probe Number = 1, T = 27.977000 C 12:14:02 Temperature Measurement, Probe Number = 2, T = 28.599000 C 12:14:03 Temperature Measurement, Probe Number = 3, T = 28.886000 C 12:14:04 Temperature Measurement, Probe Number = 4, T = 30.744000 C 12:14:04 Temperature Measurement, Probe Number = 5, T = 24.589000 C 12:14:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658561 V 12:14:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658561 (V, A, ohm, ...), Measured Value = 124.392090 (C, atm, Hz, ...) 12:14:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155421 V 12:14:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155421 (V, A, ohm, ...), Measured Value = 11.656575 (C, atm, Hz, ...) 12:14:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.51 P3 = Bottom Coil, Value = 27.98 P4 = Top Coil, Value = 28.60 P5 = Water In, Value = 28.89 P6 = Water Out, Value = 30.74 P7 = Ambient, Value = 24.59 P8 = Supply Pres(psi), Value = 124.39 P9 = Return Pres(psi), Value = 11.66 12:15:06 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:15:07 MAIN (V) Voltage Measurement, V = 6.546207 V 12:15:10 Temperature Measurement, Probe Number = 0, T = 25.511000 C 12:15:11 Temperature Measurement, Probe Number = 1, T = 27.890000 C 12:15:11 Temperature Measurement, Probe Number = 2, T = 28.404000 C 12:15:12 Temperature Measurement, Probe Number = 3, T = 28.903000 C 12:15:13 Temperature Measurement, Probe Number = 4, T = 30.735000 C 12:15:13 Temperature Measurement, Probe Number = 5, T = 24.630000 C 12:15:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656531 V 12:15:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656531 (V, A, ohm, ...), Measured Value = 124.239810 (C, atm, Hz, ...) 12:15:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157630 V 12:15:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157630 (V, A, ohm, ...), Measured Value = 11.822243 (C, atm, Hz, ...) 12:15:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.51 P3 = Bottom Coil, Value = 27.89 P4 = Top Coil, Value = 28.40 P5 = Water In, Value = 28.90 P6 = Water Out, Value = 30.73 P7 = Ambient, Value = 24.63 P8 = Supply Pres(psi), Value = 124.24 P9 = Return Pres(psi), Value = 11.82 12:16:15 Magnet Current for MAIN, Imag = 164.9804 A Vtrans = 1.649861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:16:16 MAIN (V) Voltage Measurement, V = 6.546132 V 12:16:19 Temperature Measurement, Probe Number = 0, T = 25.496000 C 12:16:20 Temperature Measurement, Probe Number = 1, T = 27.840000 C 12:16:20 Temperature Measurement, Probe Number = 2, T = 28.246000 C 12:16:21 Temperature Measurement, Probe Number = 3, T = 28.875000 C 12:16:22 Temperature Measurement, Probe Number = 4, T = 30.660000 C 12:16:22 Temperature Measurement, Probe Number = 5, T = 24.579000 C 12:16:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662800 V 12:16:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662800 (V, A, ohm, ...), Measured Value = 124.710030 (C, atm, Hz, ...) 12:16:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158173 V 12:16:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158173 (V, A, ohm, ...), Measured Value = 11.862982 (C, atm, Hz, ...) 12:16:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.50 P3 = Bottom Coil, Value = 27.84 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.88 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.58 P8 = Supply Pres(psi), Value = 124.71 P9 = Return Pres(psi), Value = 11.86 12:17:24 Magnet Current for MAIN, Imag = 164.9809 A Vtrans = 1.649866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:17:25 MAIN (V) Voltage Measurement, V = 6.545985 V 12:17:28 Temperature Measurement, Probe Number = 0, T = 25.513000 C 12:17:29 Temperature Measurement, Probe Number = 1, T = 27.927000 C 12:17:29 Temperature Measurement, Probe Number = 2, T = 28.279000 C 12:17:30 Temperature Measurement, Probe Number = 3, T = 28.847000 C 12:17:31 Temperature Measurement, Probe Number = 4, T = 30.658000 C 12:17:31 Temperature Measurement, Probe Number = 5, T = 24.606000 C 12:17:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658410 V 12:17:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658410 (V, A, ohm, ...), Measured Value = 124.380758 (C, atm, Hz, ...) 12:17:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157636 V 12:17:32 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157636 (V, A, ohm, ...), Measured Value = 11.822715 (C, atm, Hz, ...) 12:17:32 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.51 P3 = Bottom Coil, Value = 27.93 P4 = Top Coil, Value = 28.28 P5 = Water In, Value = 28.85 P6 = Water Out, Value = 30.66 P7 = Ambient, Value = 24.61 P8 = Supply Pres(psi), Value = 124.38 P9 = Return Pres(psi), Value = 11.82 12:18:33 Magnet Current for MAIN, Imag = 164.9808 A Vtrans = 1.649865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:18:34 MAIN (V) Voltage Measurement, V = 6.545735 V 12:18:37 Temperature Measurement, Probe Number = 0, T = 25.528000 C 12:18:38 Temperature Measurement, Probe Number = 1, T = 27.952000 C 12:18:38 Temperature Measurement, Probe Number = 2, T = 28.366000 C 12:18:39 Temperature Measurement, Probe Number = 3, T = 28.861000 C 12:18:40 Temperature Measurement, Probe Number = 4, T = 30.717000 C 12:18:40 Temperature Measurement, Probe Number = 5, T = 24.566000 C 12:18:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.630878 V 12:18:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.630878 (V, A, ohm, ...), Measured Value = 122.315865 (C, atm, Hz, ...) 12:18:41 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158315 V 12:18:41 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158315 (V, A, ohm, ...), Measured Value = 11.873655 (C, atm, Hz, ...) 12:18:41 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.53 P3 = Bottom Coil, Value = 27.95 P4 = Top Coil, Value = 28.37 P5 = Water In, Value = 28.86 P6 = Water Out, Value = 30.72 P7 = Ambient, Value = 24.57 P8 = Supply Pres(psi), Value = 122.32 P9 = Return Pres(psi), Value = 11.87 12:19:42 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:19:43 MAIN (V) Voltage Measurement, V = 6.545089 V 12:19:46 Temperature Measurement, Probe Number = 0, T = 25.529000 C 12:19:47 Temperature Measurement, Probe Number = 1, T = 27.920000 C 12:19:47 Temperature Measurement, Probe Number = 2, T = 28.310000 C 12:19:48 Temperature Measurement, Probe Number = 3, T = 28.869000 C 12:19:49 Temperature Measurement, Probe Number = 4, T = 30.753000 C 12:19:49 Temperature Measurement, Probe Number = 5, T = 24.636000 C 12:19:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663622 V 12:19:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663622 (V, A, ohm, ...), Measured Value = 124.771650 (C, atm, Hz, ...) 12:19:50 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158319 V 12:19:50 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158319 (V, A, ohm, ...), Measured Value = 11.873940 (C, atm, Hz, ...) 12:19:50 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 25.53 P3 = Bottom Coil, Value = 27.92 P4 = Top Coil, Value = 28.31 P5 = Water In, Value = 28.87 P6 = Water Out, Value = 30.75 P7 = Ambient, Value = 24.64 P8 = Supply Pres(psi), Value = 124.77 P9 = Return Pres(psi), Value = 11.87 12:20:51 Magnet Current for MAIN, Imag = 164.9810 A Vtrans = 1.649868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:20:52 MAIN (V) Voltage Measurement, V = 6.544324 V 12:20:55 Temperature Measurement, Probe Number = 0, T = 25.560000 C 12:20:56 Temperature Measurement, Probe Number = 1, T = 27.927000 C 12:20:56 Temperature Measurement, Probe Number = 2, T = 28.442000 C 12:20:57 Temperature Measurement, Probe Number = 3, T = 28.814000 C 12:20:58 Temperature Measurement, Probe Number = 4, T = 30.741000 C 12:20:58 Temperature Measurement, Probe Number = 5, T = 24.644000 C 12:20:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663984 V 12:20:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663984 (V, A, ohm, ...), Measured Value = 124.798807 (C, atm, Hz, ...) 12:20:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156085 V 12:20:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156085 (V, A, ohm, ...), Measured Value = 11.706397 (C, atm, Hz, ...) 12:20:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.56 P3 = Bottom Coil, Value = 27.93 P4 = Top Coil, Value = 28.44 P5 = Water In, Value = 28.81 P6 = Water Out, Value = 30.74 P7 = Ambient, Value = 24.64 P8 = Supply Pres(psi), Value = 124.80 P9 = Return Pres(psi), Value = 11.71 12:22:00 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:22:01 MAIN (V) Voltage Measurement, V = 6.543832 V 12:22:04 Temperature Measurement, Probe Number = 0, T = 25.575000 C 12:22:05 Temperature Measurement, Probe Number = 1, T = 27.965000 C 12:22:06 Temperature Measurement, Probe Number = 2, T = 28.373000 C 12:22:06 Temperature Measurement, Probe Number = 3, T = 28.819000 C 12:22:07 Temperature Measurement, Probe Number = 4, T = 30.675000 C 12:22:07 Temperature Measurement, Probe Number = 5, T = 24.677000 C 12:22:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659149 V 12:22:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659149 (V, A, ohm, ...), Measured Value = 124.436198 (C, atm, Hz, ...) 12:22:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156592 V 12:22:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156592 (V, A, ohm, ...), Measured Value = 11.744423 (C, atm, Hz, ...) 12:22:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.57 P3 = Bottom Coil, Value = 27.96 P4 = Top Coil, Value = 28.37 P5 = Water In, Value = 28.82 P6 = Water Out, Value = 30.68 P7 = Ambient, Value = 24.68 P8 = Supply Pres(psi), Value = 124.44 P9 = Return Pres(psi), Value = 11.74 12:23:09 Magnet Current for MAIN, Imag = 164.9808 A Vtrans = 1.649865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:23:10 MAIN (V) Voltage Measurement, V = 6.543911 V 12:23:13 Temperature Measurement, Probe Number = 0, T = 25.585000 C 12:23:14 Temperature Measurement, Probe Number = 1, T = 28.011000 C 12:23:15 Temperature Measurement, Probe Number = 2, T = 28.494000 C 12:23:15 Temperature Measurement, Probe Number = 3, T = 28.758000 C 12:23:16 Temperature Measurement, Probe Number = 4, T = 30.606000 C 12:23:16 Temperature Measurement, Probe Number = 5, T = 24.635000 C 12:23:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.648395 V 12:23:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.648395 (V, A, ohm, ...), Measured Value = 123.629588 (C, atm, Hz, ...) 12:23:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155441 V 12:23:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155441 (V, A, ohm, ...), Measured Value = 11.658075 (C, atm, Hz, ...) 12:23:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.59 P3 = Bottom Coil, Value = 28.01 P4 = Top Coil, Value = 28.49 P5 = Water In, Value = 28.76 P6 = Water Out, Value = 30.61 P7 = Ambient, Value = 24.64 P8 = Supply Pres(psi), Value = 123.63 P9 = Return Pres(psi), Value = 11.66 12:24:18 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:24:19 MAIN (V) Voltage Measurement, V = 6.544211 V 12:24:22 Temperature Measurement, Probe Number = 0, T = 25.579000 C 12:24:23 Temperature Measurement, Probe Number = 1, T = 27.997000 C 12:24:24 Temperature Measurement, Probe Number = 2, T = 28.402000 C 12:24:24 Temperature Measurement, Probe Number = 3, T = 28.782000 C 12:24:25 Temperature Measurement, Probe Number = 4, T = 30.595000 C 12:24:25 Temperature Measurement, Probe Number = 5, T = 24.593000 C 12:24:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.642606 V 12:24:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.642606 (V, A, ohm, ...), Measured Value = 123.195427 (C, atm, Hz, ...) 12:24:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156818 V 12:24:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156818 (V, A, ohm, ...), Measured Value = 11.761373 (C, atm, Hz, ...) 12:24:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.58 P3 = Bottom Coil, Value = 28.00 P4 = Top Coil, Value = 28.40 P5 = Water In, Value = 28.78 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.59 P8 = Supply Pres(psi), Value = 123.20 P9 = Return Pres(psi), Value = 11.76 12:25:27 Magnet Current for MAIN, Imag = 164.9808 A Vtrans = 1.649865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:25:28 MAIN (V) Voltage Measurement, V = 6.543988 V 12:25:31 Temperature Measurement, Probe Number = 0, T = 25.570000 C 12:25:32 Temperature Measurement, Probe Number = 1, T = 27.922000 C 12:25:33 Temperature Measurement, Probe Number = 2, T = 28.302000 C 12:25:33 Temperature Measurement, Probe Number = 3, T = 28.795000 C 12:25:34 Temperature Measurement, Probe Number = 4, T = 30.540000 C 12:25:34 Temperature Measurement, Probe Number = 5, T = 24.534000 C 12:25:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.682955 V 12:25:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.682955 (V, A, ohm, ...), Measured Value = 126.221632 (C, atm, Hz, ...) 12:25:35 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155839 V 12:25:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155839 (V, A, ohm, ...), Measured Value = 11.687948 (C, atm, Hz, ...) 12:25:35 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.57 P3 = Bottom Coil, Value = 27.92 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.80 P6 = Water Out, Value = 30.54 P7 = Ambient, Value = 24.53 P8 = Supply Pres(psi), Value = 126.22 P9 = Return Pres(psi), Value = 11.69 12:26:36 Magnet Current for MAIN, Imag = 164.9804 A Vtrans = 1.649861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:26:37 MAIN (V) Voltage Measurement, V = 6.543523 V 12:26:40 Temperature Measurement, Probe Number = 0, T = 25.601000 C 12:26:41 Temperature Measurement, Probe Number = 1, T = 27.941000 C 12:26:42 Temperature Measurement, Probe Number = 2, T = 28.360000 C 12:26:42 Temperature Measurement, Probe Number = 3, T = 28.755000 C 12:26:43 Temperature Measurement, Probe Number = 4, T = 30.525000 C 12:26:43 Temperature Measurement, Probe Number = 5, T = 24.442000 C 12:26:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.637215 V 12:26:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.637215 (V, A, ohm, ...), Measured Value = 122.791140 (C, atm, Hz, ...) 12:26:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156561 V 12:26:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156561 (V, A, ohm, ...), Measured Value = 11.742083 (C, atm, Hz, ...) 12:26:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.60 P3 = Bottom Coil, Value = 27.94 P4 = Top Coil, Value = 28.36 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.52 P7 = Ambient, Value = 24.44 P8 = Supply Pres(psi), Value = 122.79 P9 = Return Pres(psi), Value = 11.74 12:27:45 Magnet Current for MAIN, Imag = 164.9804 A Vtrans = 1.649861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:27:46 MAIN (V) Voltage Measurement, V = 6.542728 V 12:27:49 Temperature Measurement, Probe Number = 0, T = 25.609000 C 12:27:50 Temperature Measurement, Probe Number = 1, T = 27.923000 C 12:27:51 Temperature Measurement, Probe Number = 2, T = 28.255000 C 12:27:51 Temperature Measurement, Probe Number = 3, T = 28.749000 C 12:27:52 Temperature Measurement, Probe Number = 4, T = 30.555000 C 12:27:52 Temperature Measurement, Probe Number = 5, T = 24.341000 C 12:27:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.646966 V 12:27:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.646966 (V, A, ohm, ...), Measured Value = 123.522450 (C, atm, Hz, ...) 12:27:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156826 V 12:27:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156826 (V, A, ohm, ...), Measured Value = 11.761935 (C, atm, Hz, ...) 12:27:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.61 P3 = Bottom Coil, Value = 27.92 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.55 P7 = Ambient, Value = 24.34 P8 = Supply Pres(psi), Value = 123.52 P9 = Return Pres(psi), Value = 11.76 12:28:54 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:28:55 MAIN (V) Voltage Measurement, V = 6.541670 V 12:28:58 Temperature Measurement, Probe Number = 0, T = 25.590000 C 12:28:59 Temperature Measurement, Probe Number = 1, T = 27.755000 C 12:29:00 Temperature Measurement, Probe Number = 2, T = 28.047000 C 12:29:00 Temperature Measurement, Probe Number = 3, T = 28.678000 C 12:29:01 Temperature Measurement, Probe Number = 4, T = 30.442000 C 12:29:01 Temperature Measurement, Probe Number = 5, T = 24.280000 C 12:29:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.670826 V 12:29:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670826 (V, A, ohm, ...), Measured Value = 125.311920 (C, atm, Hz, ...) 12:29:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156822 V 12:29:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156822 (V, A, ohm, ...), Measured Value = 11.761650 (C, atm, Hz, ...) 12:29:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.59 P3 = Bottom Coil, Value = 27.75 P4 = Top Coil, Value = 28.05 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.44 P7 = Ambient, Value = 24.28 P8 = Supply Pres(psi), Value = 125.31 P9 = Return Pres(psi), Value = 11.76 12:30:03 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:30:04 MAIN (V) Voltage Measurement, V = 6.540939 V 12:30:07 Temperature Measurement, Probe Number = 0, T = 25.617000 C 12:30:08 Temperature Measurement, Probe Number = 1, T = 27.773000 C 12:30:09 Temperature Measurement, Probe Number = 2, T = 28.015000 C 12:30:09 Temperature Measurement, Probe Number = 3, T = 28.647000 C 12:30:10 Temperature Measurement, Probe Number = 4, T = 30.426000 C 12:30:10 Temperature Measurement, Probe Number = 5, T = 24.334000 C 12:30:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666117 V 12:30:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666117 (V, A, ohm, ...), Measured Value = 124.958760 (C, atm, Hz, ...) 12:30:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155495 V 12:30:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155495 (V, A, ohm, ...), Measured Value = 11.662102 (C, atm, Hz, ...) 12:30:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.62 P3 = Bottom Coil, Value = 27.77 P4 = Top Coil, Value = 28.02 P5 = Water In, Value = 28.65 P6 = Water Out, Value = 30.43 P7 = Ambient, Value = 24.33 P8 = Supply Pres(psi), Value = 124.96 P9 = Return Pres(psi), Value = 11.66 12:31:12 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:31:13 MAIN (V) Voltage Measurement, V = 6.540857 V 12:31:16 Temperature Measurement, Probe Number = 0, T = 25.627000 C 12:31:17 Temperature Measurement, Probe Number = 1, T = 27.728000 C 12:31:18 Temperature Measurement, Probe Number = 2, T = 27.994000 C 12:31:18 Temperature Measurement, Probe Number = 3, T = 28.676000 C 12:31:19 Temperature Measurement, Probe Number = 4, T = 30.441000 C 12:31:19 Temperature Measurement, Probe Number = 5, T = 24.361000 C 12:31:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.665115 V 12:31:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665115 (V, A, ohm, ...), Measured Value = 124.883655 (C, atm, Hz, ...) 12:31:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155879 V 12:31:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155879 (V, A, ohm, ...), Measured Value = 11.690948 (C, atm, Hz, ...) 12:31:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.63 P3 = Bottom Coil, Value = 27.73 P4 = Top Coil, Value = 27.99 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.44 P7 = Ambient, Value = 24.36 P8 = Supply Pres(psi), Value = 124.88 P9 = Return Pres(psi), Value = 11.69 12:32:21 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:32:22 MAIN (V) Voltage Measurement, V = 6.540914 V 12:32:25 Temperature Measurement, Probe Number = 0, T = 25.638000 C 12:32:26 Temperature Measurement, Probe Number = 1, T = 27.808000 C 12:32:27 Temperature Measurement, Probe Number = 2, T = 28.098000 C 12:32:27 Temperature Measurement, Probe Number = 3, T = 28.683000 C 12:32:28 Temperature Measurement, Probe Number = 4, T = 30.523000 C 12:32:28 Temperature Measurement, Probe Number = 5, T = 24.462000 C 12:32:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.595039 V 12:32:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.595039 (V, A, ohm, ...), Measured Value = 119.627918 (C, atm, Hz, ...) 12:32:30 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154475 V 12:32:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154475 (V, A, ohm, ...), Measured Value = 11.585595 (C, atm, Hz, ...) 12:32:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.64 P3 = Bottom Coil, Value = 27.81 P4 = Top Coil, Value = 28.10 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.52 P7 = Ambient, Value = 24.46 P8 = Supply Pres(psi), Value = 119.63 P9 = Return Pres(psi), Value = 11.59 12:33:30 Magnet Current for MAIN, Imag = 164.9810 A Vtrans = 1.649868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:33:31 MAIN (V) Voltage Measurement, V = 6.541063 V 12:33:34 Temperature Measurement, Probe Number = 0, T = 25.646000 C 12:33:35 Temperature Measurement, Probe Number = 1, T = 27.872000 C 12:33:36 Temperature Measurement, Probe Number = 2, T = 28.276000 C 12:33:36 Temperature Measurement, Probe Number = 3, T = 28.694000 C 12:33:37 Temperature Measurement, Probe Number = 4, T = 30.585000 C 12:33:37 Temperature Measurement, Probe Number = 5, T = 24.496000 C 12:33:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667430 V 12:33:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667430 (V, A, ohm, ...), Measured Value = 125.057280 (C, atm, Hz, ...) 12:33:39 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157307 V 12:33:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157307 (V, A, ohm, ...), Measured Value = 11.797988 (C, atm, Hz, ...) 12:33:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.65 P3 = Bottom Coil, Value = 27.87 P4 = Top Coil, Value = 28.28 P5 = Water In, Value = 28.69 P6 = Water Out, Value = 30.59 P7 = Ambient, Value = 24.50 P8 = Supply Pres(psi), Value = 125.06 P9 = Return Pres(psi), Value = 11.80 12:34:39 Magnet Current for MAIN, Imag = 164.9809 A Vtrans = 1.649866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:34:40 MAIN (V) Voltage Measurement, V = 6.541265 V 12:34:43 Temperature Measurement, Probe Number = 0, T = 25.639000 C 12:34:44 Temperature Measurement, Probe Number = 1, T = 27.845000 C 12:34:45 Temperature Measurement, Probe Number = 2, T = 28.189000 C 12:34:45 Temperature Measurement, Probe Number = 3, T = 28.716000 C 12:34:46 Temperature Measurement, Probe Number = 4, T = 30.609000 C 12:34:46 Temperature Measurement, Probe Number = 5, T = 24.530000 C 12:34:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662542 V 12:34:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662542 (V, A, ohm, ...), Measured Value = 124.690642 (C, atm, Hz, ...) 12:34:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155417 V 12:34:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155417 (V, A, ohm, ...), Measured Value = 11.656298 (C, atm, Hz, ...) 12:34:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.64 P3 = Bottom Coil, Value = 27.84 P4 = Top Coil, Value = 28.19 P5 = Water In, Value = 28.72 P6 = Water Out, Value = 30.61 P7 = Ambient, Value = 24.53 P8 = Supply Pres(psi), Value = 124.69 P9 = Return Pres(psi), Value = 11.66 12:35:48 Magnet Current for MAIN, Imag = 164.9810 A Vtrans = 1.649868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:35:49 MAIN (V) Voltage Measurement, V = 6.541731 V 12:35:52 Temperature Measurement, Probe Number = 0, T = 25.635000 C 12:35:53 Temperature Measurement, Probe Number = 1, T = 27.777000 C 12:35:54 Temperature Measurement, Probe Number = 2, T = 28.084000 C 12:35:54 Temperature Measurement, Probe Number = 3, T = 28.717000 C 12:35:55 Temperature Measurement, Probe Number = 4, T = 30.529000 C 12:35:55 Temperature Measurement, Probe Number = 5, T = 24.556000 C 12:35:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.642602 V 12:35:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.642602 (V, A, ohm, ...), Measured Value = 123.195150 (C, atm, Hz, ...) 12:35:57 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156535 V 12:35:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156535 (V, A, ohm, ...), Measured Value = 11.740118 (C, atm, Hz, ...) 12:35:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.64 P3 = Bottom Coil, Value = 27.78 P4 = Top Coil, Value = 28.08 P5 = Water In, Value = 28.72 P6 = Water Out, Value = 30.53 P7 = Ambient, Value = 24.56 P8 = Supply Pres(psi), Value = 123.20 P9 = Return Pres(psi), Value = 11.74 12:36:57 Magnet Current for MAIN, Imag = 164.9809 A Vtrans = 1.649866 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:36:58 MAIN (V) Voltage Measurement, V = 6.541977 V 12:37:01 Temperature Measurement, Probe Number = 0, T = 25.664000 C 12:37:02 Temperature Measurement, Probe Number = 1, T = 27.834000 C 12:37:03 Temperature Measurement, Probe Number = 2, T = 28.253000 C 12:37:03 Temperature Measurement, Probe Number = 3, T = 28.687000 C 12:37:04 Temperature Measurement, Probe Number = 4, T = 30.490000 C 12:37:04 Temperature Measurement, Probe Number = 5, T = 24.385000 C 12:37:05 Sensor Voltage Measurement, Sensor Number = 0, V = 2.642571 V 12:37:05 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.642571 (V, A, ohm, ...), Measured Value = 123.192802 (C, atm, Hz, ...) 12:37:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156898 V 12:37:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156898 (V, A, ohm, ...), Measured Value = 11.767365 (C, atm, Hz, ...) 12:37:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.66 P3 = Bottom Coil, Value = 27.83 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.69 P6 = Water Out, Value = 30.49 P7 = Ambient, Value = 24.39 P8 = Supply Pres(psi), Value = 123.19 P9 = Return Pres(psi), Value = 11.77 12:38:06 Magnet Current for MAIN, Imag = 164.9803 A Vtrans = 1.649860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:38:07 MAIN (V) Voltage Measurement, V = 6.542107 V 12:38:11 Temperature Measurement, Probe Number = 0, T = 25.670000 C 12:38:11 Temperature Measurement, Probe Number = 1, T = 27.819000 C 12:38:12 Temperature Measurement, Probe Number = 2, T = 28.145000 C 12:38:12 Temperature Measurement, Probe Number = 3, T = 28.691000 C 12:38:13 Temperature Measurement, Probe Number = 4, T = 30.461000 C 12:38:13 Temperature Measurement, Probe Number = 5, T = 24.356000 C 12:38:14 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666264 V 12:38:14 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666264 (V, A, ohm, ...), Measured Value = 124.969815 (C, atm, Hz, ...) 12:38:15 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156732 V 12:38:15 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156732 (V, A, ohm, ...), Measured Value = 11.754907 (C, atm, Hz, ...) 12:38:15 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.67 P3 = Bottom Coil, Value = 27.82 P4 = Top Coil, Value = 28.14 P5 = Water In, Value = 28.69 P6 = Water Out, Value = 30.46 P7 = Ambient, Value = 24.36 P8 = Supply Pres(psi), Value = 124.97 P9 = Return Pres(psi), Value = 11.75 12:39:15 Magnet Current for MAIN, Imag = 164.9802 A Vtrans = 1.649859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:39:16 MAIN (V) Voltage Measurement, V = 6.541791 V 12:39:20 Temperature Measurement, Probe Number = 0, T = 25.648000 C 12:39:20 Temperature Measurement, Probe Number = 1, T = 27.819000 C 12:39:21 Temperature Measurement, Probe Number = 2, T = 28.121000 C 12:39:21 Temperature Measurement, Probe Number = 3, T = 28.617000 C 12:39:22 Temperature Measurement, Probe Number = 4, T = 30.424000 C 12:39:22 Temperature Measurement, Probe Number = 5, T = 24.319000 C 12:39:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.631229 V 12:39:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.631229 (V, A, ohm, ...), Measured Value = 122.342183 (C, atm, Hz, ...) 12:39:24 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155517 V 12:39:24 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155517 (V, A, ohm, ...), Measured Value = 11.663790 (C, atm, Hz, ...) 12:39:24 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.65 P3 = Bottom Coil, Value = 27.82 P4 = Top Coil, Value = 28.12 P5 = Water In, Value = 28.62 P6 = Water Out, Value = 30.42 P7 = Ambient, Value = 24.32 P8 = Supply Pres(psi), Value = 122.34 P9 = Return Pres(psi), Value = 11.66 12:40:24 Magnet Current for MAIN, Imag = 164.9800 A Vtrans = 1.649858 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:40:25 MAIN (V) Voltage Measurement, V = 6.540948 V 12:40:29 Temperature Measurement, Probe Number = 0, T = 25.656000 C 12:40:29 Temperature Measurement, Probe Number = 1, T = 27.793000 C 12:40:30 Temperature Measurement, Probe Number = 2, T = 28.193000 C 12:40:30 Temperature Measurement, Probe Number = 3, T = 28.594000 C 12:40:31 Temperature Measurement, Probe Number = 4, T = 30.413000 C 12:40:32 Temperature Measurement, Probe Number = 5, T = 24.329000 C 12:40:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.643697 V 12:40:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.643697 (V, A, ohm, ...), Measured Value = 123.277275 (C, atm, Hz, ...) 12:40:33 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155633 V 12:40:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155633 (V, A, ohm, ...), Measured Value = 11.672498 (C, atm, Hz, ...) 12:40:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.66 P3 = Bottom Coil, Value = 27.79 P4 = Top Coil, Value = 28.19 P5 = Water In, Value = 28.59 P6 = Water Out, Value = 30.41 P7 = Ambient, Value = 24.33 P8 = Supply Pres(psi), Value = 123.28 P9 = Return Pres(psi), Value = 11.67 12:41:33 Magnet Current for MAIN, Imag = 164.9799 A Vtrans = 1.649856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:41:34 MAIN (V) Voltage Measurement, V = 6.540008 V 12:41:38 Temperature Measurement, Probe Number = 0, T = 25.660000 C 12:41:38 Temperature Measurement, Probe Number = 1, T = 27.746000 C 12:41:39 Temperature Measurement, Probe Number = 2, T = 28.091000 C 12:41:39 Temperature Measurement, Probe Number = 3, T = 28.596000 C 12:41:40 Temperature Measurement, Probe Number = 4, T = 30.425000 C 12:41:41 Temperature Measurement, Probe Number = 5, T = 24.350000 C 12:41:41 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666069 V 12:41:41 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666069 (V, A, ohm, ...), Measured Value = 124.955205 (C, atm, Hz, ...) 12:41:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156080 V 12:41:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156080 (V, A, ohm, ...), Measured Value = 11.706022 (C, atm, Hz, ...) 12:41:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.66 P3 = Bottom Coil, Value = 27.75 P4 = Top Coil, Value = 28.09 P5 = Water In, Value = 28.60 P6 = Water Out, Value = 30.43 P7 = Ambient, Value = 24.35 P8 = Supply Pres(psi), Value = 124.96 P9 = Return Pres(psi), Value = 11.71 12:42:42 Magnet Current for MAIN, Imag = 164.9795 A Vtrans = 1.649853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:42:43 MAIN (V) Voltage Measurement, V = 6.538949 V 12:42:47 Temperature Measurement, Probe Number = 0, T = 25.681000 C 12:42:47 Temperature Measurement, Probe Number = 1, T = 27.766000 C 12:42:48 Temperature Measurement, Probe Number = 2, T = 28.133000 C 12:42:48 Temperature Measurement, Probe Number = 3, T = 28.592000 C 12:42:49 Temperature Measurement, Probe Number = 4, T = 30.391000 C 12:42:50 Temperature Measurement, Probe Number = 5, T = 24.432000 C 12:42:50 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663952 V 12:42:50 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663952 (V, A, ohm, ...), Measured Value = 124.796378 (C, atm, Hz, ...) 12:42:51 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156600 V 12:42:51 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156600 (V, A, ohm, ...), Measured Value = 11.744985 (C, atm, Hz, ...) 12:42:51 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.68 P3 = Bottom Coil, Value = 27.77 P4 = Top Coil, Value = 28.13 P5 = Water In, Value = 28.59 P6 = Water Out, Value = 30.39 P7 = Ambient, Value = 24.43 P8 = Supply Pres(psi), Value = 124.80 P9 = Return Pres(psi), Value = 11.74 12:43:51 Magnet Current for MAIN, Imag = 164.9795 A Vtrans = 1.649853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:43:52 MAIN (V) Voltage Measurement, V = 6.538148 V 12:43:56 Temperature Measurement, Probe Number = 0, T = 25.700000 C 12:43:56 Temperature Measurement, Probe Number = 1, T = 27.813000 C 12:43:57 Temperature Measurement, Probe Number = 2, T = 28.295000 C 12:43:57 Temperature Measurement, Probe Number = 3, T = 28.557000 C 12:43:58 Temperature Measurement, Probe Number = 4, T = 30.446000 C 12:43:59 Temperature Measurement, Probe Number = 5, T = 24.384000 C 12:43:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.670406 V 12:43:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670406 (V, A, ohm, ...), Measured Value = 125.280450 (C, atm, Hz, ...) 12:44:00 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157798 V 12:44:00 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157798 (V, A, ohm, ...), Measured Value = 11.834887 (C, atm, Hz, ...) 12:44:00 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.70 P3 = Bottom Coil, Value = 27.81 P4 = Top Coil, Value = 28.30 P5 = Water In, Value = 28.56 P6 = Water Out, Value = 30.45 P7 = Ambient, Value = 24.38 P8 = Supply Pres(psi), Value = 125.28 P9 = Return Pres(psi), Value = 11.83 12:45:00 Magnet Current for MAIN, Imag = 164.9793 A Vtrans = 1.649850 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:45:01 MAIN (V) Voltage Measurement, V = 6.537353 V 12:45:05 Temperature Measurement, Probe Number = 0, T = 25.722000 C 12:45:05 Temperature Measurement, Probe Number = 1, T = 27.850000 C 12:45:06 Temperature Measurement, Probe Number = 2, T = 28.393000 C 12:45:06 Temperature Measurement, Probe Number = 3, T = 28.567000 C 12:45:07 Temperature Measurement, Probe Number = 4, T = 30.473000 C 12:45:08 Temperature Measurement, Probe Number = 5, T = 24.498000 C 12:45:08 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658871 V 12:45:08 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658871 (V, A, ohm, ...), Measured Value = 124.415310 (C, atm, Hz, ...) 12:45:09 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157498 V 12:45:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157498 (V, A, ohm, ...), Measured Value = 11.812320 (C, atm, Hz, ...) 12:45:09 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.72 P3 = Bottom Coil, Value = 27.85 P4 = Top Coil, Value = 28.39 P5 = Water In, Value = 28.57 P6 = Water Out, Value = 30.47 P7 = Ambient, Value = 24.50 P8 = Supply Pres(psi), Value = 124.42 P9 = Return Pres(psi), Value = 11.81 12:46:09 Magnet Current for MAIN, Imag = 164.9803 A Vtrans = 1.649860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:46:10 MAIN (V) Voltage Measurement, V = 6.536970 V 12:46:14 Temperature Measurement, Probe Number = 0, T = 25.730000 C 12:46:14 Temperature Measurement, Probe Number = 1, T = 27.856000 C 12:46:15 Temperature Measurement, Probe Number = 2, T = 28.355000 C 12:46:15 Temperature Measurement, Probe Number = 3, T = 28.568000 C 12:46:16 Temperature Measurement, Probe Number = 4, T = 30.488000 C 12:46:17 Temperature Measurement, Probe Number = 5, T = 24.380000 C 12:46:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.653603 V 12:46:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653603 (V, A, ohm, ...), Measured Value = 124.020202 (C, atm, Hz, ...) 12:46:18 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156442 V 12:46:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156442 (V, A, ohm, ...), Measured Value = 11.733180 (C, atm, Hz, ...) 12:46:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.73 P3 = Bottom Coil, Value = 27.86 P4 = Top Coil, Value = 28.36 P5 = Water In, Value = 28.57 P6 = Water Out, Value = 30.49 P7 = Ambient, Value = 24.38 P8 = Supply Pres(psi), Value = 124.02 P9 = Return Pres(psi), Value = 11.73 12:47:19 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:47:19 MAIN (V) Voltage Measurement, V = 6.536809 V 12:47:23 Temperature Measurement, Probe Number = 0, T = 25.737000 C 12:47:23 Temperature Measurement, Probe Number = 1, T = 27.782000 C 12:47:24 Temperature Measurement, Probe Number = 2, T = 28.243000 C 12:47:24 Temperature Measurement, Probe Number = 3, T = 28.582000 C 12:47:25 Temperature Measurement, Probe Number = 4, T = 30.490000 C 12:47:26 Temperature Measurement, Probe Number = 5, T = 24.548000 C 12:47:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667618 V 12:47:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667618 (V, A, ohm, ...), Measured Value = 125.071328 (C, atm, Hz, ...) 12:47:27 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157385 V 12:47:27 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157385 (V, A, ohm, ...), Measured Value = 11.803890 (C, atm, Hz, ...) 12:47:27 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.74 P3 = Bottom Coil, Value = 27.78 P4 = Top Coil, Value = 28.24 P5 = Water In, Value = 28.58 P6 = Water Out, Value = 30.49 P7 = Ambient, Value = 24.55 P8 = Supply Pres(psi), Value = 125.07 P9 = Return Pres(psi), Value = 11.80 12:48:28 Magnet Current for MAIN, Imag = 164.9804 A Vtrans = 1.649861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:48:28 MAIN (V) Voltage Measurement, V = 6.537152 V 12:48:32 Temperature Measurement, Probe Number = 0, T = 25.744000 C 12:48:32 Temperature Measurement, Probe Number = 1, T = 27.778000 C 12:48:33 Temperature Measurement, Probe Number = 2, T = 28.255000 C 12:48:33 Temperature Measurement, Probe Number = 3, T = 28.574000 C 12:48:34 Temperature Measurement, Probe Number = 4, T = 30.431000 C 12:48:35 Temperature Measurement, Probe Number = 5, T = 24.580000 C 12:48:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663410 V 12:48:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663410 (V, A, ohm, ...), Measured Value = 124.755727 (C, atm, Hz, ...) 12:48:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155957 V 12:48:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155957 (V, A, ohm, ...), Measured Value = 11.696752 (C, atm, Hz, ...) 12:48:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.74 P3 = Bottom Coil, Value = 27.78 P4 = Top Coil, Value = 28.25 P5 = Water In, Value = 28.57 P6 = Water Out, Value = 30.43 P7 = Ambient, Value = 24.58 P8 = Supply Pres(psi), Value = 124.76 P9 = Return Pres(psi), Value = 11.70 12:49:37 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:49:37 MAIN (V) Voltage Measurement, V = 6.537538 V 12:49:41 Temperature Measurement, Probe Number = 0, T = 25.731000 C 12:49:41 Temperature Measurement, Probe Number = 1, T = 27.814000 C 12:49:42 Temperature Measurement, Probe Number = 2, T = 28.369000 C 12:49:43 Temperature Measurement, Probe Number = 3, T = 28.601000 C 12:49:43 Temperature Measurement, Probe Number = 4, T = 30.484000 C 12:49:44 Temperature Measurement, Probe Number = 5, T = 24.541000 C 12:49:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667443 V 12:49:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667443 (V, A, ohm, ...), Measured Value = 125.058218 (C, atm, Hz, ...) 12:49:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155812 V 12:49:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155812 (V, A, ohm, ...), Measured Value = 11.685892 (C, atm, Hz, ...) 12:49:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.73 P3 = Bottom Coil, Value = 27.81 P4 = Top Coil, Value = 28.37 P5 = Water In, Value = 28.60 P6 = Water Out, Value = 30.48 P7 = Ambient, Value = 24.54 P8 = Supply Pres(psi), Value = 125.06 P9 = Return Pres(psi), Value = 11.69 12:50:46 Magnet Current for MAIN, Imag = 164.9808 A Vtrans = 1.649865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:50:46 MAIN (V) Voltage Measurement, V = 6.538274 V 12:50:50 Temperature Measurement, Probe Number = 0, T = 25.724000 C 12:50:50 Temperature Measurement, Probe Number = 1, T = 27.804000 C 12:50:51 Temperature Measurement, Probe Number = 2, T = 28.274000 C 12:50:52 Temperature Measurement, Probe Number = 3, T = 28.600000 C 12:50:52 Temperature Measurement, Probe Number = 4, T = 30.470000 C 12:50:53 Temperature Measurement, Probe Number = 5, T = 24.572000 C 12:50:53 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666553 V 12:50:53 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666553 (V, A, ohm, ...), Measured Value = 124.991445 (C, atm, Hz, ...) 12:50:54 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157963 V 12:50:54 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157963 (V, A, ohm, ...), Measured Value = 11.847248 (C, atm, Hz, ...) 12:50:54 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.72 P3 = Bottom Coil, Value = 27.80 P4 = Top Coil, Value = 28.27 P5 = Water In, Value = 28.60 P6 = Water Out, Value = 30.47 P7 = Ambient, Value = 24.57 P8 = Supply Pres(psi), Value = 124.99 P9 = Return Pres(psi), Value = 11.85 12:51:55 Magnet Current for MAIN, Imag = 164.9808 A Vtrans = 1.649865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:51:55 MAIN (V) Voltage Measurement, V = 6.538891 V 12:51:59 Temperature Measurement, Probe Number = 0, T = 25.751000 C 12:51:59 Temperature Measurement, Probe Number = 1, T = 27.846000 C 12:52:00 Temperature Measurement, Probe Number = 2, T = 28.389000 C 12:52:01 Temperature Measurement, Probe Number = 3, T = 28.538000 C 12:52:01 Temperature Measurement, Probe Number = 4, T = 30.438000 C 12:52:02 Temperature Measurement, Probe Number = 5, T = 24.548000 C 12:52:02 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658861 V 12:52:02 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658861 (V, A, ohm, ...), Measured Value = 124.414560 (C, atm, Hz, ...) 12:52:03 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158299 V 12:52:03 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158299 (V, A, ohm, ...), Measured Value = 11.872440 (C, atm, Hz, ...) 12:52:03 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.75 P3 = Bottom Coil, Value = 27.85 P4 = Top Coil, Value = 28.39 P5 = Water In, Value = 28.54 P6 = Water Out, Value = 30.44 P7 = Ambient, Value = 24.55 P8 = Supply Pres(psi), Value = 124.41 P9 = Return Pres(psi), Value = 11.87 12:53:04 Magnet Current for MAIN, Imag = 164.9803 A Vtrans = 1.649860 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:53:04 MAIN (V) Voltage Measurement, V = 6.539449 V 12:53:08 Temperature Measurement, Probe Number = 0, T = 25.768000 C 12:53:08 Temperature Measurement, Probe Number = 1, T = 27.792000 C 12:53:09 Temperature Measurement, Probe Number = 2, T = 28.310000 C 12:53:10 Temperature Measurement, Probe Number = 3, T = 28.619000 C 12:53:10 Temperature Measurement, Probe Number = 4, T = 30.506000 C 12:53:11 Temperature Measurement, Probe Number = 5, T = 24.591000 C 12:53:11 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667008 V 12:53:11 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667008 (V, A, ohm, ...), Measured Value = 125.025630 (C, atm, Hz, ...) 12:53:12 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158699 V 12:53:12 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158699 (V, A, ohm, ...), Measured Value = 11.902410 (C, atm, Hz, ...) 12:53:12 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.77 P3 = Bottom Coil, Value = 27.79 P4 = Top Coil, Value = 28.31 P5 = Water In, Value = 28.62 P6 = Water Out, Value = 30.51 P7 = Ambient, Value = 24.59 P8 = Supply Pres(psi), Value = 125.03 P9 = Return Pres(psi), Value = 11.90 12:54:13 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:54:13 MAIN (V) Voltage Measurement, V = 6.539777 V 12:54:17 Temperature Measurement, Probe Number = 0, T = 25.773000 C 12:54:17 Temperature Measurement, Probe Number = 1, T = 27.909000 C 12:54:18 Temperature Measurement, Probe Number = 2, T = 28.400000 C 12:54:19 Temperature Measurement, Probe Number = 3, T = 28.677000 C 12:54:19 Temperature Measurement, Probe Number = 4, T = 30.571000 C 12:54:20 Temperature Measurement, Probe Number = 5, T = 24.642000 C 12:54:20 Sensor Voltage Measurement, Sensor Number = 0, V = 2.679026 V 12:54:20 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.679026 (V, A, ohm, ...), Measured Value = 125.926920 (C, atm, Hz, ...) 12:54:21 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157218 V 12:54:21 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157218 (V, A, ohm, ...), Measured Value = 11.791343 (C, atm, Hz, ...) 12:54:21 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.77 P3 = Bottom Coil, Value = 27.91 P4 = Top Coil, Value = 28.40 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.57 P7 = Ambient, Value = 24.64 P8 = Supply Pres(psi), Value = 125.93 P9 = Return Pres(psi), Value = 11.79 12:55:22 Magnet Current for MAIN, Imag = 164.9810 A Vtrans = 1.649868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:55:22 MAIN (V) Voltage Measurement, V = 6.540158 V 12:55:26 Temperature Measurement, Probe Number = 0, T = 25.813000 C 12:55:26 Temperature Measurement, Probe Number = 1, T = 28.021000 C 12:55:27 Temperature Measurement, Probe Number = 2, T = 28.503000 C 12:55:28 Temperature Measurement, Probe Number = 3, T = 28.611000 C 12:55:28 Temperature Measurement, Probe Number = 4, T = 30.560000 C 12:55:29 Temperature Measurement, Probe Number = 5, T = 24.709000 C 12:55:29 Sensor Voltage Measurement, Sensor Number = 0, V = 2.638530 V 12:55:29 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.638530 (V, A, ohm, ...), Measured Value = 122.889758 (C, atm, Hz, ...) 12:55:30 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157523 V 12:55:30 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157523 (V, A, ohm, ...), Measured Value = 11.814188 (C, atm, Hz, ...) 12:55:30 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.81 P3 = Bottom Coil, Value = 28.02 P4 = Top Coil, Value = 28.50 P5 = Water In, Value = 28.61 P6 = Water Out, Value = 30.56 P7 = Ambient, Value = 24.71 P8 = Supply Pres(psi), Value = 122.89 P9 = Return Pres(psi), Value = 11.81 12:56:31 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:56:31 MAIN (V) Voltage Measurement, V = 6.540463 V 12:56:35 Temperature Measurement, Probe Number = 0, T = 25.807000 C 12:56:35 Temperature Measurement, Probe Number = 1, T = 27.966000 C 12:56:36 Temperature Measurement, Probe Number = 2, T = 28.427000 C 12:56:37 Temperature Measurement, Probe Number = 3, T = 28.685000 C 12:56:37 Temperature Measurement, Probe Number = 4, T = 30.602000 C 12:56:38 Temperature Measurement, Probe Number = 5, T = 24.763000 C 12:56:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659767 V 12:56:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659767 (V, A, ohm, ...), Measured Value = 124.482555 (C, atm, Hz, ...) 12:56:39 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157941 V 12:56:39 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157941 (V, A, ohm, ...), Measured Value = 11.845560 (C, atm, Hz, ...) 12:56:39 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.81 P3 = Bottom Coil, Value = 27.97 P4 = Top Coil, Value = 28.43 P5 = Water In, Value = 28.68 P6 = Water Out, Value = 30.60 P7 = Ambient, Value = 24.76 P8 = Supply Pres(psi), Value = 124.48 P9 = Return Pres(psi), Value = 11.85 12:57:40 Magnet Current for MAIN, Imag = 164.9807 A Vtrans = 1.649864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:57:40 MAIN (V) Voltage Measurement, V = 6.540903 V 12:57:44 Temperature Measurement, Probe Number = 0, T = 25.808000 C 12:57:44 Temperature Measurement, Probe Number = 1, T = 27.981000 C 12:57:45 Temperature Measurement, Probe Number = 2, T = 28.412000 C 12:57:46 Temperature Measurement, Probe Number = 3, T = 28.715000 C 12:57:46 Temperature Measurement, Probe Number = 4, T = 30.624000 C 12:57:47 Temperature Measurement, Probe Number = 5, T = 24.735000 C 12:57:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659173 V 12:57:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659173 (V, A, ohm, ...), Measured Value = 124.437975 (C, atm, Hz, ...) 12:57:48 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155649 V 12:57:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155649 (V, A, ohm, ...), Measured Value = 11.673713 (C, atm, Hz, ...) 12:57:48 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.81 P3 = Bottom Coil, Value = 27.98 P4 = Top Coil, Value = 28.41 P5 = Water In, Value = 28.71 P6 = Water Out, Value = 30.62 P7 = Ambient, Value = 24.73 P8 = Supply Pres(psi), Value = 124.44 P9 = Return Pres(psi), Value = 11.67 12:58:49 Magnet Current for MAIN, Imag = 164.9805 A Vtrans = 1.649863 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 12:58:49 MAIN (V) Voltage Measurement, V = 6.541144 V 12:58:53 Temperature Measurement, Probe Number = 0, T = 25.826000 C 12:58:53 Temperature Measurement, Probe Number = 1, T = 27.982000 C 12:58:54 Temperature Measurement, Probe Number = 2, T = 28.467000 C 12:58:55 Temperature Measurement, Probe Number = 3, T = 28.734000 C 12:58:55 Temperature Measurement, Probe Number = 4, T = 30.632000 C 12:58:56 Temperature Measurement, Probe Number = 5, T = 24.720000 C 12:58:56 Sensor Voltage Measurement, Sensor Number = 0, V = 2.679057 V 12:58:56 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.679057 (V, A, ohm, ...), Measured Value = 125.929260 (C, atm, Hz, ...) 12:58:57 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156406 V 12:58:57 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156406 (V, A, ohm, ...), Measured Value = 11.730465 (C, atm, Hz, ...) 12:58:57 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 25.83 P3 = Bottom Coil, Value = 27.98 P4 = Top Coil, Value = 28.47 P5 = Water In, Value = 28.73 P6 = Water Out, Value = 30.63 P7 = Ambient, Value = 24.72 P8 = Supply Pres(psi), Value = 125.93 P9 = Return Pres(psi), Value = 11.73 12:58:57 Magnet system MAIN current ramping to 0.0000 A... 12:59:18 Magnet system MAIN current ramping to 185.0000 A... 12:59:41 Magnet system MAIN current ramping to 0.0000 A... 13:00:04 Magnet system MAIN current ramping to 185.0000 A... 13:00:26 Magnet system MAIN current ramping to 0.0000 A... 13:00:49 Magnet system MAIN current ramping to 185.0000 A... 13:01:12 Magnet system MAIN current ramping to 0.0000 A... 13:01:37 Position moved: 0.000000 m 13:01:40 Magnet system MAIN current ramping to 0.0000 A... 13:01:51 Magnet Current for MAIN, Imag = 0.0177 A Vtrans = 0.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:01:52 MAIN (V) Voltage Measurement, V = 0.000786 V 13:01:55 Temperature Measurement, Probe Number = 0, T = 25.851000 C 13:01:56 Temperature Measurement, Probe Number = 1, T = 27.455000 C 13:01:56 Temperature Measurement, Probe Number = 2, T = 28.051000 C 13:01:57 Temperature Measurement, Probe Number = 3, T = 28.766000 C 13:01:58 Temperature Measurement, Probe Number = 4, T = 29.766000 C 13:01:58 Temperature Measurement, Probe Number = 5, T = 24.818000 C 13:01:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.635170 V 13:01:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.635170 (V, A, ohm, ...), Measured Value = 122.637743 (C, atm, Hz, ...) 13:01:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155828 V 13:01:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155828 (V, A, ohm, ...), Measured Value = 11.687107 (C, atm, Hz, ...) 13:01:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.02 P1 = MAIN (V), Value = 0.00 P2 = Yoke, Value = 25.85 P3 = Bottom Coil, Value = 27.45 P4 = Top Coil, Value = 28.05 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 29.77 P7 = Ambient, Value = 24.82 P8 = Supply Pres(psi), Value = 122.64 P9 = Return Pres(psi), Value = 11.69 13:01:59 Magnetic Field Measurement Measuring the magnet strength... 13:01:59 Integrated Voltage Measurement... 13:02:00 Magnet Current for MAIN, Imag = 0.0178 A Vtrans = 0.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000019170 Vs 13:02:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005583 Vs 13:02:17 Magnet Current for MAIN, Imag = 0.0177 A Vtrans = 0.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:02:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000018275 Vs 13:02:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000005209 Vs 13:02:33 Magnet Current for MAIN, Imag = 0.0178 A Vtrans = 0.000235 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:02:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020293 Vs 13:02:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004139 Vs 13:02:49 Magnet Current for MAIN, Imag = 0.0177 A Vtrans = 0.000234 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:02:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020114 Vs 13:03:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000004145 Vs 13:03:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000012116 +- 0.000000233 Vs 13:03:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000012116 +- 0.000000233 Vs BL = -0.00012116 +- 0.00000233 Tm 13:03:08 Position moved: 0.000000 m 13:03:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00012 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00012 0.00000 -0.00012 0.00000 13:03:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00012 0.00000 SL = -0.0001212 +- 0.0000023 Tm^2/m^n 13:03:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001212 +- 0.0000023 Tm^2/m^n 13:03:11 Position moved: 0.000000 m 13:03:11 Magnet system MAIN current ramping to 15.0000 A... 13:03:23 Magnet Current for MAIN, Imag = 14.9981 A Vtrans = 0.150038 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:03:23 MAIN (V) Voltage Measurement, V = 0.591760 V 13:03:27 Temperature Measurement, Probe Number = 0, T = 25.865000 C 13:03:28 Temperature Measurement, Probe Number = 1, T = 27.126000 C 13:03:28 Temperature Measurement, Probe Number = 2, T = 27.680000 C 13:03:29 Temperature Measurement, Probe Number = 3, T = 28.793000 C 13:03:29 Temperature Measurement, Probe Number = 4, T = 29.052000 C 13:03:30 Temperature Measurement, Probe Number = 5, T = 24.804000 C 13:03:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.632013 V 13:03:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.632013 (V, A, ohm, ...), Measured Value = 122.400998 (C, atm, Hz, ...) 13:03:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156756 V 13:03:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156756 (V, A, ohm, ...), Measured Value = 11.756693 (C, atm, Hz, ...) 13:03:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 15.00 P1 = MAIN (V), Value = 0.59 P2 = Yoke, Value = 25.86 P3 = Bottom Coil, Value = 27.13 P4 = Top Coil, Value = 27.68 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 29.05 P7 = Ambient, Value = 24.80 P8 = Supply Pres(psi), Value = 122.40 P9 = Return Pres(psi), Value = 11.76 13:03:31 Magnetic Field Measurement Measuring the magnet strength... 13:03:31 Integrated Voltage Measurement... 13:03:32 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:03:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000587086 Vs 13:03:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000575455 Vs 13:03:49 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:03:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000587389 Vs 13:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000575022 Vs 13:04:05 Magnet Current for MAIN, Imag = 14.9983 A Vtrans = 0.150041 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:04:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589089 Vs 13:04:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000572055 Vs 13:04:21 Magnet Current for MAIN, Imag = 14.9980 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:04:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000587811 Vs 13:04:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000574913 Vs 13:04:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000581103 +- 0.000000311 Vs 13:04:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000581103 +- 0.000000311 Vs BL = -0.00581103 +- 0.00000311 Tm 13:04:40 Position moved: 0.000000 m 13:04:40 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00581 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00581 0.00000 -0.00581 0.00000 13:04:40 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00581 0.00000 SL = -0.0058110 +- 0.0000031 Tm^2/m^n 13:04:40 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058110 +- 0.0000031 Tm^2/m^n Remeasure 13:04:40 Magnetic Field Measurement Measuring the magnet strength... 13:04:40 Integrated Voltage Measurement... 13:04:41 Magnet Current for MAIN, Imag = 14.9980 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:04:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588765 Vs 13:04:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573012 Vs 13:04:58 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150036 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000590416 Vs 13:05:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573589 Vs 13:05:13 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150036 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:05:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589737 Vs 13:05:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573283 Vs 13:05:29 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:05:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589887 Vs 13:05:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000572245 Vs 13:05:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000581367 +- 0.000000431 Vs 13:05:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000581367 +- 0.000000431 Vs BL = -0.00581367 +- 0.00000431 Tm 13:05:49 Position moved: 0.000000 m 13:05:49 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00581 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00581 0.00000 -0.00581 0.00000 13:05:49 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00581 0.00000 SL = -0.0058137 +- 0.0000043 Tm^2/m^n 13:05:49 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058137 +- 0.0000043 Tm^2/m^n Remeasure 13:05:49 Magnetic Field Measurement Measuring the magnet strength... 13:05:49 Integrated Voltage Measurement... 13:05:49 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150036 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:05:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000590264 Vs 13:06:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573916 Vs 13:06:06 Magnet Current for MAIN, Imag = 14.9978 A Vtrans = 0.150035 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:06:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000587361 Vs 13:06:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000572223 Vs 13:06:22 Magnet Current for MAIN, Imag = 14.9980 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:06:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000590302 Vs 13:06:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573798 Vs 13:06:38 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:06:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589959 Vs 13:06:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573414 Vs 13:06:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000581405 +- 0.000000944 Vs 13:06:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000581405 +- 0.000000944 Vs BL = -0.00581405 +- 0.00000944 Tm 13:06:57 Position moved: 0.000000 m 13:06:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00581 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00581 0.00001 -0.00581 0.00000 13:06:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00581 0.00001 SL = -0.0058140 +- 0.0000094 Tm^2/m^n 13:06:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058140 +- 0.0000094 Tm^2/m^n Remeasure 13:06:57 Magnetic Field Measurement Measuring the magnet strength... 13:06:57 Integrated Voltage Measurement... 13:06:58 Magnet Current for MAIN, Imag = 14.9980 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:07:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588706 Vs 13:07:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000574314 Vs 13:07:15 Magnet Current for MAIN, Imag = 14.9978 A Vtrans = 0.150035 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:07:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589916 Vs 13:07:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573473 Vs 13:07:31 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150036 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:07:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589756 Vs 13:07:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000572783 Vs 13:07:47 Magnet Current for MAIN, Imag = 14.9979 A Vtrans = 0.150037 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:07:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589476 Vs 13:08:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000574461 Vs 13:08:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000581611 +- 0.000000256 Vs 13:08:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000581611 +- 0.000000256 Vs BL = -0.00581611 +- 0.00000256 Tm 13:08:06 Position moved: 0.000000 m 13:08:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00582 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00582 0.00000 -0.00582 0.00000 13:08:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00582 0.00000 SL = -0.0058161 +- 0.0000026 Tm^2/m^n 13:08:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058161 +- 0.0000026 Tm^2/m^n Remeasure 13:08:06 Magnetic Field Measurement Measuring the magnet strength... 13:08:06 Integrated Voltage Measurement... 13:08:07 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:08:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000589981 Vs 13:08:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573200 Vs 13:08:24 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150039 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:08:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588952 Vs 13:08:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000572397 Vs 13:08:40 Magnet Current for MAIN, Imag = 14.9982 A Vtrans = 0.150040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:08:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000590178 Vs 13:08:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000573964 Vs 13:08:56 Magnet Current for MAIN, Imag = 14.9983 A Vtrans = 0.150040 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:09:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000590026 Vs 13:09:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000574646 Vs 13:09:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000581668 +- 0.000000633 Vs 13:09:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000581668 +- 0.000000633 Vs BL = -0.00581668 +- 0.00000633 Tm 13:09:15 Position moved: 0.000000 m 13:09:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00582 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00582 0.00001 -0.00582 0.00000 13:09:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00582 0.00001 SL = -0.0058167 +- 0.0000063 Tm^2/m^n 13:09:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058167 +- 0.0000063 Tm^2/m^n 13:09:18 Position moved: 0.000000 m 13:09:18 Magnet system MAIN current ramping to 30.0000 A... 13:09:30 Magnet Current for MAIN, Imag = 30.0297 A Vtrans = 0.300355 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:09:31 MAIN (V) Voltage Measurement, V = 1.185262 V 13:09:34 Temperature Measurement, Probe Number = 0, T = 25.864000 C 13:09:35 Temperature Measurement, Probe Number = 1, T = 27.095000 C 13:09:35 Temperature Measurement, Probe Number = 2, T = 27.442000 C 13:09:36 Temperature Measurement, Probe Number = 3, T = 28.791000 C 13:09:37 Temperature Measurement, Probe Number = 4, T = 28.751000 C 13:09:37 Temperature Measurement, Probe Number = 5, T = 24.740000 C 13:09:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.643002 V 13:09:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.643002 (V, A, ohm, ...), Measured Value = 123.225112 (C, atm, Hz, ...) 13:09:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156713 V 13:09:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156713 (V, A, ohm, ...), Measured Value = 11.753505 (C, atm, Hz, ...) 13:09:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 30.03 P1 = MAIN (V), Value = 1.19 P2 = Yoke, Value = 25.86 P3 = Bottom Coil, Value = 27.09 P4 = Top Coil, Value = 27.44 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 28.75 P7 = Ambient, Value = 24.74 P8 = Supply Pres(psi), Value = 123.23 P9 = Return Pres(psi), Value = 11.75 13:09:38 Magnetic Field Measurement Measuring the magnet strength... 13:09:38 Integrated Voltage Measurement... 13:09:39 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:09:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001160552 Vs 13:09:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001144531 Vs 13:09:56 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:10:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001160365 Vs 13:10:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001144691 Vs 13:10:12 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:10:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001160468 Vs 13:10:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001146764 Vs 13:10:28 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:10:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001161993 Vs 13:10:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001145816 Vs 13:10:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001153147 +- 0.000000621 Vs 13:10:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001153147 +- 0.000000621 Vs BL = -0.01153147 +- 0.00000621 Tm 13:10:47 Position moved: 0.000000 m 13:10:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01153 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01153 0.00001 -0.01153 0.00000 13:10:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01153 0.00001 SL = -0.0115315 +- 0.0000062 Tm^2/m^n 13:10:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0115315 +- 0.0000062 Tm^2/m^n Remeasure 13:10:47 Magnetic Field Measurement Measuring the magnet strength... 13:10:47 Integrated Voltage Measurement... 13:10:48 Magnet Current for MAIN, Imag = 30.0296 A Vtrans = 0.300353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:10:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001162123 Vs 13:11:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001147730 Vs 13:11:05 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:11:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001156654 Vs 13:11:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001149087 Vs 13:11:21 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:11:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001158579 Vs 13:11:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001147031 Vs 13:11:37 Magnet Current for MAIN, Imag = 30.0296 A Vtrans = 0.300353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:11:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001158079 Vs 13:11:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001145569 Vs 13:11:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001153106 +- 0.000001129 Vs 13:11:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001153106 +- 0.000001129 Vs BL = -0.01153106 +- 0.00001129 Tm 13:11:56 Position moved: 0.000000 m 13:11:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01153 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01153 0.00001 -0.01153 0.00000 13:11:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01153 0.00001 SL = -0.0115311 +- 0.0000113 Tm^2/m^n 13:11:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0115311 +- 0.0000113 Tm^2/m^n Remeasure 13:11:56 Magnetic Field Measurement Measuring the magnet strength... 13:11:56 Integrated Voltage Measurement... 13:11:57 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:12:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001159709 Vs 13:12:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001146420 Vs 13:12:14 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:12:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001160085 Vs 13:12:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001148326 Vs 13:12:30 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300353 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:12:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001158089 Vs 13:12:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001148435 Vs 13:12:46 Magnet Current for MAIN, Imag = 30.0293 A Vtrans = 0.300350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:12:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001162072 Vs 13:13:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001145309 Vs 13:13:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001153556 +- 0.000000438 Vs 13:13:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001153556 +- 0.000000438 Vs BL = -0.01153556 +- 0.00000438 Tm 13:13:05 Position moved: 0.000000 m 13:13:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01154 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01154 0.00000 -0.01154 0.00000 13:13:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01154 0.00000 SL = -0.0115356 +- 0.0000044 Tm^2/m^n 13:13:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0115356 +- 0.0000044 Tm^2/m^n Remeasure 13:13:05 Magnetic Field Measurement Measuring the magnet strength... 13:13:05 Integrated Voltage Measurement... 13:13:05 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:13:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001161687 Vs 13:13:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001143344 Vs 13:13:22 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:13:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001162173 Vs 13:13:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001145376 Vs 13:13:38 Magnet Current for MAIN, Imag = 30.0295 A Vtrans = 0.300352 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:13:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001160437 Vs 13:13:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001143528 Vs 13:13:54 Magnet Current for MAIN, Imag = 30.0293 A Vtrans = 0.300350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:14:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001159300 Vs 13:14:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001148229 Vs 13:14:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001153009 +- 0.000000783 Vs 13:14:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001153009 +- 0.000000783 Vs BL = -0.01153009 +- 0.00000783 Tm 13:14:13 Position moved: 0.000000 m 13:14:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01153 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01153 0.00001 -0.01153 0.00000 13:14:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01153 0.00001 SL = -0.0115301 +- 0.0000078 Tm^2/m^n 13:14:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0115301 +- 0.0000078 Tm^2/m^n Remeasure 13:14:13 Magnetic Field Measurement Measuring the magnet strength... 13:14:13 Integrated Voltage Measurement... 13:14:14 Magnet Current for MAIN, Imag = 30.0291 A Vtrans = 0.300349 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:14:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001159420 Vs 13:14:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001145608 Vs 13:14:31 Magnet Current for MAIN, Imag = 30.0294 A Vtrans = 0.300351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:14:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001159807 Vs 13:14:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001146971 Vs 13:14:47 Magnet Current for MAIN, Imag = 30.0292 A Vtrans = 0.300350 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:14:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001158882 Vs 13:15:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001148553 Vs 13:15:03 Magnet Current for MAIN, Imag = 30.0293 A Vtrans = 0.300351 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:15:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001161147 Vs 13:15:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001148522 Vs 13:15:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001153614 +- 0.000000831 Vs 13:15:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001153614 +- 0.000000831 Vs BL = -0.01153614 +- 0.00000831 Tm 13:15:22 Position moved: 0.000000 m 13:15:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01154 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01154 0.00001 -0.01154 0.00000 13:15:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01154 0.00001 SL = -0.0115361 +- 0.0000083 Tm^2/m^n 13:15:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0115361 +- 0.0000083 Tm^2/m^n 13:15:25 Position moved: 0.000000 m 13:15:25 Magnet system MAIN current ramping to 45.0000 A... 13:15:37 Magnet Current for MAIN, Imag = 44.9828 A Vtrans = 0.449886 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:15:37 MAIN (V) Voltage Measurement, V = 1.776084 V 13:15:41 Temperature Measurement, Probe Number = 0, T = 25.863000 C 13:15:42 Temperature Measurement, Probe Number = 1, T = 27.094000 C 13:15:42 Temperature Measurement, Probe Number = 2, T = 27.580000 C 13:15:43 Temperature Measurement, Probe Number = 3, T = 28.798000 C 13:15:43 Temperature Measurement, Probe Number = 4, T = 28.835000 C 13:15:44 Temperature Measurement, Probe Number = 5, T = 24.598000 C 13:15:44 Sensor Voltage Measurement, Sensor Number = 0, V = 2.623642 V 13:15:44 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.623642 (V, A, ohm, ...), Measured Value = 121.773165 (C, atm, Hz, ...) 13:15:45 Sensor Voltage Measurement, Sensor Number = 1, V = 1.153634 V 13:15:45 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.153634 (V, A, ohm, ...), Measured Value = 11.522565 (C, atm, Hz, ...) 13:15:45 Magnet Test Parameter Measurements P0 = MAIN, Value = 44.98 P1 = MAIN (V), Value = 1.78 P2 = Yoke, Value = 25.86 P3 = Bottom Coil, Value = 27.09 P4 = Top Coil, Value = 27.58 P5 = Water In, Value = 28.80 P6 = Water Out, Value = 28.84 P7 = Ambient, Value = 24.60 P8 = Supply Pres(psi), Value = 121.77 P9 = Return Pres(psi), Value = 11.52 13:15:45 Magnetic Field Measurement Measuring the magnet strength... 13:15:45 Integrated Voltage Measurement... 13:15:46 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:15:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001729507 Vs 13:16:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001711987 Vs 13:16:03 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:16:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001731423 Vs 13:16:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001715067 Vs 13:16:19 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:16:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001728876 Vs 13:16:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001713367 Vs 13:16:35 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:16:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001727261 Vs 13:16:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001715283 Vs 13:16:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001721596 +- 0.000000971 Vs 13:16:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001721596 +- 0.000000971 Vs BL = -0.01721596 +- 0.00000971 Tm 13:16:54 Position moved: 0.000000 m 13:16:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01722 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01722 0.00001 -0.01722 0.00000 13:16:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01722 0.00001 SL = -0.0172160 +- 0.0000097 Tm^2/m^n 13:16:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0172160 +- 0.0000097 Tm^2/m^n Remeasure 13:16:54 Magnetic Field Measurement Measuring the magnet strength... 13:16:54 Integrated Voltage Measurement... 13:16:55 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:17:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001730066 Vs 13:17:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001716039 Vs 13:17:12 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:17:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001727244 Vs 13:17:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001716997 Vs 13:17:28 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:17:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001729691 Vs 13:17:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001717720 Vs 13:17:43 Magnet Current for MAIN, Imag = 44.9822 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:17:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001730838 Vs 13:17:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001716915 Vs 13:17:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001723189 +- 0.000000689 Vs 13:17:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001723189 +- 0.000000689 Vs BL = -0.01723189 +- 0.00000689 Tm 13:18:02 Position moved: 0.000000 m 13:18:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01723 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01723 0.00001 -0.01723 0.00000 13:18:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01723 0.00001 SL = -0.0172319 +- 0.0000069 Tm^2/m^n 13:18:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0172319 +- 0.0000069 Tm^2/m^n Remeasure 13:18:02 Magnetic Field Measurement Measuring the magnet strength... 13:18:02 Integrated Voltage Measurement... 13:18:03 Magnet Current for MAIN, Imag = 44.9826 A Vtrans = 0.449883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:18:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001731935 Vs 13:18:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001718086 Vs 13:18:20 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:18:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001728244 Vs 13:18:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001715065 Vs 13:18:36 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:18:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001730156 Vs 13:18:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001717824 Vs 13:18:52 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:18:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001729129 Vs 13:19:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001713862 Vs 13:19:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001723038 +- 0.000001507 Vs 13:19:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001723038 +- 0.000001507 Vs BL = -0.01723038 +- 0.00001507 Tm 13:19:11 Position moved: 0.000000 m 13:19:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01723 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01723 0.00002 -0.01723 0.00000 13:19:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01723 0.00002 SL = -0.0172304 +- 0.0000151 Tm^2/m^n 13:19:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0172304 +- 0.0000151 Tm^2/m^n Remeasure 13:19:11 Magnetic Field Measurement Measuring the magnet strength... 13:19:11 Integrated Voltage Measurement... 13:19:12 Magnet Current for MAIN, Imag = 44.9824 A Vtrans = 0.449882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:19:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001733062 Vs 13:19:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001720693 Vs 13:19:29 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:19:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001728727 Vs 13:19:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001718338 Vs 13:19:45 Magnet Current for MAIN, Imag = 44.9824 A Vtrans = 0.449881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:19:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001724112 Vs 13:20:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001716356 Vs 13:20:01 Magnet Current for MAIN, Imag = 44.9823 A Vtrans = 0.449880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:20:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001729993 Vs 13:20:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001713476 Vs 13:20:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001723095 +- 0.000002476 Vs 13:20:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001723095 +- 0.000002476 Vs BL = -0.01723095 +- 0.00002476 Tm 13:20:20 Position moved: 0.000000 m 13:20:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01723 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01723 0.00002 -0.01723 0.00000 13:20:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01723 0.00002 SL = -0.0172309 +- 0.0000248 Tm^2/m^n 13:20:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0172309 +- 0.0000248 Tm^2/m^n Remeasure 13:20:20 Magnetic Field Measurement Measuring the magnet strength... 13:20:20 Integrated Voltage Measurement... 13:20:21 Magnet Current for MAIN, Imag = 44.9825 A Vtrans = 0.449882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:20:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001730110 Vs 13:20:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001719120 Vs 13:20:37 Magnet Current for MAIN, Imag = 44.9826 A Vtrans = 0.449883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:20:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001729411 Vs 13:20:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001717326 Vs 13:20:53 Magnet Current for MAIN, Imag = 44.9824 A Vtrans = 0.449881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:21:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001731251 Vs 13:21:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001716538 Vs 13:21:09 Magnet Current for MAIN, Imag = 44.9824 A Vtrans = 0.449881 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:21:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001731478 Vs 13:21:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001718513 Vs 13:21:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001724218 +- 0.000000630 Vs 13:21:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001724218 +- 0.000000630 Vs BL = -0.01724218 +- 0.00000630 Tm 13:21:28 Position moved: 0.000000 m 13:21:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01724 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01724 0.00001 -0.01724 0.00000 13:21:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01724 0.00001 SL = -0.0172422 +- 0.0000063 Tm^2/m^n 13:21:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0172422 +- 0.0000063 Tm^2/m^n 13:21:31 Position moved: 0.000000 m 13:21:31 Magnet system MAIN current ramping to 60.0000 A... 13:21:43 Magnet Current for MAIN, Imag = 60.0080 A Vtrans = 0.600138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:21:44 MAIN (V) Voltage Measurement, V = 2.370577 V 13:21:47 Temperature Measurement, Probe Number = 0, T = 25.883000 C 13:21:48 Temperature Measurement, Probe Number = 1, T = 27.195000 C 13:21:49 Temperature Measurement, Probe Number = 2, T = 27.550000 C 13:21:49 Temperature Measurement, Probe Number = 3, T = 28.945000 C 13:21:50 Temperature Measurement, Probe Number = 4, T = 29.025000 C 13:21:50 Temperature Measurement, Probe Number = 5, T = 24.680000 C 13:21:51 Sensor Voltage Measurement, Sensor Number = 0, V = 2.668357 V 13:21:51 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.668357 (V, A, ohm, ...), Measured Value = 125.126767 (C, atm, Hz, ...) 13:21:52 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155481 V 13:21:52 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155481 (V, A, ohm, ...), Measured Value = 11.661075 (C, atm, Hz, ...) 13:21:52 Magnet Test Parameter Measurements P0 = MAIN, Value = 60.01 P1 = MAIN (V), Value = 2.37 P2 = Yoke, Value = 25.88 P3 = Bottom Coil, Value = 27.20 P4 = Top Coil, Value = 27.55 P5 = Water In, Value = 28.95 P6 = Water Out, Value = 29.02 P7 = Ambient, Value = 24.68 P8 = Supply Pres(psi), Value = 125.13 P9 = Return Pres(psi), Value = 11.66 13:21:52 Magnetic Field Measurement Measuring the magnet strength... 13:21:52 Integrated Voltage Measurement... 13:21:52 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:22:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002305115 Vs 13:22:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002290485 Vs 13:22:09 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:22:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002295304 Vs 13:22:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002287903 Vs 13:22:25 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:22:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002295244 Vs 13:22:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002293054 Vs 13:22:41 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:22:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002303444 Vs 13:22:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002293419 Vs 13:22:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002295496 +- 0.000002779 Vs 13:22:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002295496 +- 0.000002779 Vs BL = -0.02295496 +- 0.00002779 Tm 13:23:01 Position moved: 0.000000 m 13:23:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02295 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02295 0.00003 -0.02295 0.00000 13:23:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02295 0.00003 SL = -0.0229550 +- 0.0000278 Tm^2/m^n 13:23:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0229550 +- 0.0000278 Tm^2/m^n Remeasure 13:23:01 Magnetic Field Measurement Measuring the magnet strength... 13:23:01 Integrated Voltage Measurement... 13:23:01 Magnet Current for MAIN, Imag = 60.0083 A Vtrans = 0.600140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:23:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002306712 Vs 13:23:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002294446 Vs 13:23:18 Magnet Current for MAIN, Imag = 60.0079 A Vtrans = 0.600137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:23:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002301426 Vs 13:23:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002292300 Vs 13:23:34 Magnet Current for MAIN, Imag = 60.0078 A Vtrans = 0.600135 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:23:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002302723 Vs 13:23:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002288153 Vs 13:23:50 Magnet Current for MAIN, Imag = 60.0079 A Vtrans = 0.600136 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:23:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002301326 Vs 13:24:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002292970 Vs 13:24:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002297507 +- 0.000001888 Vs 13:24:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002297507 +- 0.000001888 Vs BL = -0.02297507 +- 0.00001888 Tm 13:24:09 Position moved: 0.000000 m 13:24:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02298 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02298 0.00002 -0.02298 0.00000 13:24:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02298 0.00002 SL = -0.0229751 +- 0.0000189 Tm^2/m^n 13:24:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0229751 +- 0.0000189 Tm^2/m^n Remeasure 13:24:09 Magnetic Field Measurement Measuring the magnet strength... 13:24:09 Integrated Voltage Measurement... 13:24:10 Magnet Current for MAIN, Imag = 60.0079 A Vtrans = 0.600137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:24:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002298796 Vs 13:24:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002283881 Vs 13:24:27 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:24:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002302318 Vs 13:24:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002290791 Vs 13:24:43 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:24:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002300448 Vs 13:24:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002303382 Vs 13:24:58 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:25:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002302778 Vs 13:25:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002285604 Vs 13:25:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002296000 +- 0.000003882 Vs 13:25:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002296000 +- 0.000003882 Vs BL = -0.02296000 +- 0.00003882 Tm 13:25:18 Position moved: 0.000000 m 13:25:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02296 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02296 0.00004 -0.02296 0.00000 13:25:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02296 0.00004 SL = -0.0229600 +- 0.0000388 Tm^2/m^n 13:25:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0229600 +- 0.0000388 Tm^2/m^n Remeasure 13:25:18 Magnetic Field Measurement Measuring the magnet strength... 13:25:18 Integrated Voltage Measurement... 13:25:18 Magnet Current for MAIN, Imag = 60.0083 A Vtrans = 0.600140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:25:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002300387 Vs 13:25:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002296934 Vs 13:25:35 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:25:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002305292 Vs 13:25:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002287937 Vs 13:25:51 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:25:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002302727 Vs 13:26:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002288732 Vs 13:26:07 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:26:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002309135 Vs 13:26:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002297703 Vs 13:26:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002298606 +- 0.000002975 Vs 13:26:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002298606 +- 0.000002975 Vs BL = -0.02298606 +- 0.00002975 Tm 13:26:26 Position moved: 0.000000 m 13:26:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02299 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02299 0.00003 -0.02299 0.00000 13:26:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02299 0.00003 SL = -0.0229861 +- 0.0000298 Tm^2/m^n 13:26:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0229861 +- 0.0000298 Tm^2/m^n Remeasure 13:26:26 Magnetic Field Measurement Measuring the magnet strength... 13:26:26 Integrated Voltage Measurement... 13:26:27 Magnet Current for MAIN, Imag = 60.0084 A Vtrans = 0.600141 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:26:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002307486 Vs 13:26:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002289330 Vs 13:26:44 Magnet Current for MAIN, Imag = 60.0082 A Vtrans = 0.600139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:26:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002304434 Vs 13:26:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002287042 Vs 13:27:00 Magnet Current for MAIN, Imag = 60.0081 A Vtrans = 0.600138 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:27:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002299929 Vs 13:27:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002286695 Vs 13:27:16 Magnet Current for MAIN, Imag = 60.0083 A Vtrans = 0.600140 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:27:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002303196 Vs 13:27:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002287801 Vs 13:27:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002295739 +- 0.000001808 Vs 13:27:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002295739 +- 0.000001808 Vs BL = -0.02295739 +- 0.00001808 Tm 13:27:35 Position moved: 0.000000 m 13:27:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02296 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02296 0.00002 -0.02296 0.00000 13:27:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02296 0.00002 SL = -0.0229574 +- 0.0000181 Tm^2/m^n 13:27:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0229574 +- 0.0000181 Tm^2/m^n 13:27:38 Position moved: 0.000000 m 13:27:38 Magnet system MAIN current ramping to 75.0000 A... 13:27:50 Magnet Current for MAIN, Imag = 75.0387 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:27:51 MAIN (V) Voltage Measurement, V = 2.964879 V 13:27:54 Temperature Measurement, Probe Number = 0, T = 25.911000 C 13:27:55 Temperature Measurement, Probe Number = 1, T = 27.219000 C 13:27:55 Temperature Measurement, Probe Number = 2, T = 27.776000 C 13:27:56 Temperature Measurement, Probe Number = 3, T = 28.823000 C 13:27:57 Temperature Measurement, Probe Number = 4, T = 29.092000 C 13:27:57 Temperature Measurement, Probe Number = 5, T = 24.738000 C 13:27:58 Sensor Voltage Measurement, Sensor Number = 0, V = 2.664060 V 13:27:58 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664060 (V, A, ohm, ...), Measured Value = 124.804523 (C, atm, Hz, ...) 13:27:58 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156993 V 13:27:58 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156993 (V, A, ohm, ...), Measured Value = 11.774482 (C, atm, Hz, ...) 13:27:58 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.04 P1 = MAIN (V), Value = 2.96 P2 = Yoke, Value = 25.91 P3 = Bottom Coil, Value = 27.22 P4 = Top Coil, Value = 27.78 P5 = Water In, Value = 28.82 P6 = Water Out, Value = 29.09 P7 = Ambient, Value = 24.74 P8 = Supply Pres(psi), Value = 124.80 P9 = Return Pres(psi), Value = 11.77 13:27:58 Magnetic Field Measurement Measuring the magnet strength... 13:27:58 Integrated Voltage Measurement... 13:27:59 Magnet Current for MAIN, Imag = 75.0387 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:28:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877540 Vs 13:28:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002868830 Vs 13:28:16 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:28:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002879945 Vs 13:28:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002852118 Vs 13:28:32 Magnet Current for MAIN, Imag = 75.0387 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:28:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002873826 Vs 13:28:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002880810 Vs 13:28:48 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:28:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002874362 Vs 13:29:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002860202 Vs 13:29:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002870954 +- 0.000004560 Vs 13:29:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002870954 +- 0.000004560 Vs BL = -0.02870954 +- 0.00004560 Tm 13:29:06 Position moved: 0.000000 m 13:29:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02871 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02871 0.00005 -0.02871 0.00000 13:29:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02871 0.00005 SL = -0.0287095 +- 0.0000456 Tm^2/m^n 13:29:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287095 +- 0.0000456 Tm^2/m^n Remeasure 13:29:06 Magnetic Field Measurement Measuring the magnet strength... 13:29:06 Integrated Voltage Measurement... 13:29:07 Magnet Current for MAIN, Imag = 75.0383 A Vtrans = 0.750441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:29:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002878728 Vs 13:29:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002853236 Vs 13:29:24 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002876082 Vs 13:29:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002865237 Vs 13:29:40 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:29:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877560 Vs 13:29:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002868498 Vs 13:29:56 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002873633 Vs 13:30:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002875109 Vs 13:30:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002871010 +- 0.000003193 Vs 13:30:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002871010 +- 0.000003193 Vs BL = -0.02871010 +- 0.00003193 Tm 13:30:15 Position moved: 0.000000 m 13:30:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02871 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02871 0.00003 -0.02871 0.00000 13:30:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02871 0.00003 SL = -0.0287101 +- 0.0000319 Tm^2/m^n 13:30:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287101 +- 0.0000319 Tm^2/m^n Remeasure 13:30:15 Magnetic Field Measurement Measuring the magnet strength... 13:30:15 Integrated Voltage Measurement... 13:30:16 Magnet Current for MAIN, Imag = 75.0384 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:30:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877618 Vs 13:30:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002863841 Vs 13:30:33 Magnet Current for MAIN, Imag = 75.0383 A Vtrans = 0.750441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:30:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002875712 Vs 13:30:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002862341 Vs 13:30:49 Magnet Current for MAIN, Imag = 75.0386 A Vtrans = 0.750443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:30:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877607 Vs 13:31:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002860568 Vs 13:31:05 Magnet Current for MAIN, Imag = 75.0386 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:31:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002876577 Vs 13:31:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002859708 Vs 13:31:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002869246 +- 0.000000934 Vs 13:31:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002869246 +- 0.000000934 Vs BL = -0.02869246 +- 0.00000934 Tm 13:31:24 Position moved: 0.000000 m 13:31:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02869 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02869 0.00001 -0.02869 0.00000 13:31:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02869 0.00001 SL = -0.0286925 +- 0.0000093 Tm^2/m^n 13:31:24 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0286925 +- 0.0000093 Tm^2/m^n Remeasure 13:31:24 Magnetic Field Measurement Measuring the magnet strength... 13:31:24 Integrated Voltage Measurement... 13:31:24 Magnet Current for MAIN, Imag = 75.0387 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:31:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002876789 Vs 13:31:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002865778 Vs 13:31:42 Magnet Current for MAIN, Imag = 75.0384 A Vtrans = 0.750441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:31:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877924 Vs 13:31:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002869097 Vs 13:31:58 Magnet Current for MAIN, Imag = 75.0386 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:32:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002868360 Vs 13:32:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002878560 Vs 13:32:13 Magnet Current for MAIN, Imag = 75.0385 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:32:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002876208 Vs 13:32:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002860528 Vs 13:32:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002871656 +- 0.000002100 Vs 13:32:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002871656 +- 0.000002100 Vs BL = -0.02871656 +- 0.00002100 Tm 13:32:32 Position moved: 0.000000 m 13:32:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02872 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02872 0.00002 -0.02872 0.00000 13:32:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02872 0.00002 SL = -0.0287166 +- 0.0000210 Tm^2/m^n 13:32:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287166 +- 0.0000210 Tm^2/m^n Remeasure 13:32:32 Magnetic Field Measurement Measuring the magnet strength... 13:32:32 Integrated Voltage Measurement... 13:32:33 Magnet Current for MAIN, Imag = 75.0384 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:32:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002879968 Vs 13:32:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002861102 Vs 13:32:50 Magnet Current for MAIN, Imag = 75.0384 A Vtrans = 0.750441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:32:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002874449 Vs 13:33:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002866319 Vs 13:33:06 Magnet Current for MAIN, Imag = 75.0384 A Vtrans = 0.750442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:33:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002877124 Vs 13:33:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002866672 Vs 13:33:22 Magnet Current for MAIN, Imag = 75.0386 A Vtrans = 0.750444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:33:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002873606 Vs 13:33:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002870684 Vs 13:33:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002871240 +- 0.000000787 Vs 13:33:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002871240 +- 0.000000787 Vs BL = -0.02871240 +- 0.00000787 Tm 13:33:41 Position moved: 0.000000 m 13:33:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02871 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02871 0.00001 -0.02871 0.00000 13:33:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02871 0.00001 SL = -0.0287124 +- 0.0000079 Tm^2/m^n 13:33:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287124 +- 0.0000079 Tm^2/m^n 13:33:44 Position moved: 0.000000 m 13:33:44 Magnet system MAIN current ramping to 90.0000 A... 13:33:56 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899985 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:33:57 MAIN (V) Voltage Measurement, V = 3.556911 V 13:34:00 Temperature Measurement, Probe Number = 0, T = 25.955000 C 13:34:01 Temperature Measurement, Probe Number = 1, T = 27.369000 C 13:34:01 Temperature Measurement, Probe Number = 2, T = 27.698000 C 13:34:02 Temperature Measurement, Probe Number = 3, T = 28.832000 C 13:34:03 Temperature Measurement, Probe Number = 4, T = 29.178000 C 13:34:03 Temperature Measurement, Probe Number = 5, T = 24.794000 C 13:34:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662736 V 13:34:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662736 (V, A, ohm, ...), Measured Value = 124.705163 (C, atm, Hz, ...) 13:34:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154239 V 13:34:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154239 (V, A, ohm, ...), Measured Value = 11.567895 (C, atm, Hz, ...) 13:34:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 89.99 P1 = MAIN (V), Value = 3.56 P2 = Yoke, Value = 25.95 P3 = Bottom Coil, Value = 27.37 P4 = Top Coil, Value = 27.70 P5 = Water In, Value = 28.83 P6 = Water Out, Value = 29.18 P7 = Ambient, Value = 24.79 P8 = Supply Pres(psi), Value = 124.71 P9 = Return Pres(psi), Value = 11.57 13:34:04 Magnetic Field Measurement Measuring the magnet strength... 13:34:04 Integrated Voltage Measurement... 13:34:05 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:34:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003442529 Vs 13:34:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003428651 Vs 13:34:22 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:34:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003445656 Vs 13:34:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003432986 Vs 13:34:38 Magnet Current for MAIN, Imag = 89.9932 A Vtrans = 0.899989 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:34:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003452455 Vs 13:34:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003434447 Vs 13:34:54 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899985 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:35:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003451415 Vs 13:35:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003433677 Vs 13:35:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003440227 +- 0.000003086 Vs 13:35:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003440227 +- 0.000003086 Vs BL = -0.03440227 +- 0.00003086 Tm 13:35:13 Position moved: 0.000000 m 13:35:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03440 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03440 0.00003 -0.03440 0.00000 13:35:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03440 0.00003 SL = -0.0344023 +- 0.0000309 Tm^2/m^n 13:35:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0344023 +- 0.0000309 Tm^2/m^n Remeasure 13:35:13 Magnetic Field Measurement Measuring the magnet strength... 13:35:13 Integrated Voltage Measurement... 13:35:14 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:35:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003447331 Vs 13:35:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003429985 Vs 13:35:31 Magnet Current for MAIN, Imag = 89.9930 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:35:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003446920 Vs 13:35:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003425127 Vs 13:35:47 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:35:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003446243 Vs 13:36:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003431551 Vs 13:36:03 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899985 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:36:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003449733 Vs 13:36:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003430216 Vs 13:36:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003438388 +- 0.000001453 Vs 13:36:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003438388 +- 0.000001453 Vs BL = -0.03438388 +- 0.00001453 Tm 13:36:22 Position moved: 0.000000 m 13:36:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03438 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03438 0.00001 -0.03438 0.00000 13:36:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03438 0.00001 SL = -0.0343839 +- 0.0000145 Tm^2/m^n 13:36:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0343839 +- 0.0000145 Tm^2/m^n Remeasure 13:36:22 Magnetic Field Measurement Measuring the magnet strength... 13:36:22 Integrated Voltage Measurement... 13:36:22 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899985 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:36:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003449754 Vs 13:36:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003436075 Vs 13:36:39 Magnet Current for MAIN, Imag = 89.9930 A Vtrans = 0.899988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:36:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003445379 Vs 13:36:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003421567 Vs 13:36:55 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:37:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003449668 Vs 13:37:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003431932 Vs 13:37:11 Magnet Current for MAIN, Imag = 89.9931 A Vtrans = 0.899988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:37:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003449008 Vs 13:37:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003426715 Vs 13:37:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003438762 +- 0.000003542 Vs 13:37:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003438762 +- 0.000003542 Vs BL = -0.03438762 +- 0.00003542 Tm 13:37:30 Position moved: 0.000000 m 13:37:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03439 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03439 0.00004 -0.03439 0.00000 13:37:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03439 0.00004 SL = -0.0343876 +- 0.0000354 Tm^2/m^n 13:37:30 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0343876 +- 0.0000354 Tm^2/m^n Remeasure 13:37:30 Magnetic Field Measurement Measuring the magnet strength... 13:37:30 Integrated Voltage Measurement... 13:37:31 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:37:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003445863 Vs 13:37:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003419966 Vs 13:37:48 Magnet Current for MAIN, Imag = 89.9928 A Vtrans = 0.899986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:37:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003447274 Vs 13:38:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003432749 Vs 13:38:04 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:38:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003439899 Vs 13:38:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003436678 Vs 13:38:20 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:38:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003446420 Vs 13:38:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003429983 Vs 13:38:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003437354 +- 0.000002663 Vs 13:38:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003437354 +- 0.000002663 Vs BL = -0.03437354 +- 0.00002663 Tm 13:38:38 Position moved: 0.000000 m 13:38:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03437 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03437 0.00003 -0.03437 0.00000 13:38:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03437 0.00003 SL = -0.0343735 +- 0.0000266 Tm^2/m^n 13:38:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0343735 +- 0.0000266 Tm^2/m^n Remeasure 13:38:38 Magnetic Field Measurement Measuring the magnet strength... 13:38:38 Integrated Voltage Measurement... 13:38:39 Magnet Current for MAIN, Imag = 89.9931 A Vtrans = 0.899988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:38:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003446424 Vs 13:38:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003432350 Vs 13:38:56 Magnet Current for MAIN, Imag = 89.9930 A Vtrans = 0.899988 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:39:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003448703 Vs 13:39:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003440780 Vs 13:39:12 Magnet Current for MAIN, Imag = 89.9929 A Vtrans = 0.899987 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:39:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003445600 Vs 13:39:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003437820 Vs 13:39:28 Magnet Current for MAIN, Imag = 89.9932 A Vtrans = 0.899989 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:39:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003447075 Vs 13:39:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003433161 Vs 13:39:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003441489 +- 0.000002057 Vs 13:39:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003441489 +- 0.000002057 Vs BL = -0.03441489 +- 0.00002057 Tm 13:39:47 Position moved: 0.000000 m 13:39:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03441 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03441 0.00002 -0.03441 0.00000 13:39:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03441 0.00002 SL = -0.0344149 +- 0.0000206 Tm^2/m^n 13:39:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0344149 +- 0.0000206 Tm^2/m^n 13:39:50 Position moved: 0.000000 m 13:39:50 Magnet system MAIN current ramping to 105.0000 A... 13:40:02 Magnet Current for MAIN, Imag = 105.0209 A Vtrans = 1.050266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:40:02 MAIN (V) Voltage Measurement, V = 4.152754 V 13:40:06 Temperature Measurement, Probe Number = 0, T = 25.974000 C 13:40:07 Temperature Measurement, Probe Number = 1, T = 27.428000 C 13:40:07 Temperature Measurement, Probe Number = 2, T = 27.863000 C 13:40:08 Temperature Measurement, Probe Number = 3, T = 28.821000 C 13:40:08 Temperature Measurement, Probe Number = 4, T = 29.380000 C 13:40:09 Temperature Measurement, Probe Number = 5, T = 24.843000 C 13:40:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.674969 V 13:40:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.674969 (V, A, ohm, ...), Measured Value = 125.622645 (C, atm, Hz, ...) 13:40:10 Sensor Voltage Measurement, Sensor Number = 1, V = 1.159252 V 13:40:10 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.159252 (V, A, ohm, ...), Measured Value = 11.943892 (C, atm, Hz, ...) 13:40:10 Magnet Test Parameter Measurements P0 = MAIN, Value = 105.02 P1 = MAIN (V), Value = 4.15 P2 = Yoke, Value = 25.97 P3 = Bottom Coil, Value = 27.43 P4 = Top Coil, Value = 27.86 P5 = Water In, Value = 28.82 P6 = Water Out, Value = 29.38 P7 = Ambient, Value = 24.84 P8 = Supply Pres(psi), Value = 125.62 P9 = Return Pres(psi), Value = 11.94 13:40:10 Magnetic Field Measurement Measuring the magnet strength... 13:40:10 Integrated Voltage Measurement... 13:40:11 Magnet Current for MAIN, Imag = 105.0209 A Vtrans = 1.050266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:40:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004017148 Vs 13:40:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004003081 Vs 13:40:28 Magnet Current for MAIN, Imag = 105.0208 A Vtrans = 1.050265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:40:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004012461 Vs 13:40:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004014421 Vs 13:40:44 Magnet Current for MAIN, Imag = 105.0207 A Vtrans = 1.050265 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004019526 Vs 13:40:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004012993 Vs 13:40:59 Magnet Current for MAIN, Imag = 105.0207 A Vtrans = 1.050264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004027333 Vs 13:41:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003997138 Vs 13:41:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004013013 +- 0.000002221 Vs 13:41:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004013013 +- 0.000002221 Vs BL = -0.04013013 +- 0.00002221 Tm 13:41:18 Position moved: 0.000000 m 13:41:18 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04013 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04013 0.00002 -0.04013 0.00000 13:41:18 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04013 0.00002 SL = -0.0401301 +- 0.0000222 Tm^2/m^n 13:41:18 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0401301 +- 0.0000222 Tm^2/m^n Remeasure 13:41:18 Magnetic Field Measurement Measuring the magnet strength... 13:41:18 Integrated Voltage Measurement... 13:41:19 Magnet Current for MAIN, Imag = 105.0208 A Vtrans = 1.050266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:41:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004022618 Vs 13:41:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003997812 Vs 13:41:36 Magnet Current for MAIN, Imag = 105.0209 A Vtrans = 1.050266 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:41:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004018808 Vs 13:41:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004000856 Vs 13:41:52 Magnet Current for MAIN, Imag = 105.0206 A Vtrans = 1.050264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:42:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004016503 Vs 13:42:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004010244 Vs 13:42:08 Magnet Current for MAIN, Imag = 105.0207 A Vtrans = 1.050264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004018037 Vs 13:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004007170 Vs 13:42:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004011506 +- 0.000001513 Vs 13:42:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004011506 +- 0.000001513 Vs BL = -0.04011506 +- 0.00001513 Tm 13:42:27 Position moved: 0.000000 m 13:42:27 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04012 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04012 0.00002 -0.04012 0.00000 13:42:27 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04012 0.00002 SL = -0.0401151 +- 0.0000151 Tm^2/m^n 13:42:27 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0401151 +- 0.0000151 Tm^2/m^n Remeasure 13:42:27 Magnetic Field Measurement Measuring the magnet strength... 13:42:27 Integrated Voltage Measurement... 13:42:28 Magnet Current for MAIN, Imag = 105.0205 A Vtrans = 1.050263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:42:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004023519 Vs 13:42:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004001140 Vs 13:42:45 Magnet Current for MAIN, Imag = 105.0204 A Vtrans = 1.050262 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:42:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004017680 Vs 13:43:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004009552 Vs 13:43:01 Magnet Current for MAIN, Imag = 105.0204 A Vtrans = 1.050261 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:43:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004011332 Vs 13:43:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004009119 Vs 13:43:17 Magnet Current for MAIN, Imag = 105.0207 A Vtrans = 1.050264 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:43:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004021762 Vs 13:43:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004004574 Vs 13:43:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004012335 +- 0.000001302 Vs 13:43:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004012335 +- 0.000001302 Vs BL = -0.04012335 +- 0.00001302 Tm 13:43:36 Position moved: 0.000000 m 13:43:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04012 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04012 0.00001 -0.04012 0.00000 13:43:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04012 0.00001 SL = -0.0401233 +- 0.0000130 Tm^2/m^n 13:43:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0401233 +- 0.0000130 Tm^2/m^n 13:43:39 Position moved: 0.000000 m 13:43:39 Magnet system MAIN current ramping to 120.0000 A... 13:43:51 Magnet Current for MAIN, Imag = 120.0389 A Vtrans = 1.200447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:43:52 MAIN (V) Voltage Measurement, V = 4.749299 V 13:43:55 Temperature Measurement, Probe Number = 0, T = 25.984000 C 13:43:56 Temperature Measurement, Probe Number = 1, T = 27.468000 C 13:43:56 Temperature Measurement, Probe Number = 2, T = 27.757000 C 13:43:57 Temperature Measurement, Probe Number = 3, T = 28.824000 C 13:43:58 Temperature Measurement, Probe Number = 4, T = 29.538000 C 13:43:58 Temperature Measurement, Probe Number = 5, T = 24.844000 C 13:43:59 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656133 V 13:43:59 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656133 (V, A, ohm, ...), Measured Value = 124.209937 (C, atm, Hz, ...) 13:43:59 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156413 V 13:43:59 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156413 (V, A, ohm, ...), Measured Value = 11.730938 (C, atm, Hz, ...) 13:43:59 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.04 P1 = MAIN (V), Value = 4.75 P2 = Yoke, Value = 25.98 P3 = Bottom Coil, Value = 27.47 P4 = Top Coil, Value = 27.76 P5 = Water In, Value = 28.82 P6 = Water Out, Value = 29.54 P7 = Ambient, Value = 24.84 P8 = Supply Pres(psi), Value = 124.21 P9 = Return Pres(psi), Value = 11.73 13:43:59 Magnetic Field Measurement Measuring the magnet strength... 13:43:59 Integrated Voltage Measurement... 13:44:00 Magnet Current for MAIN, Imag = 120.0391 A Vtrans = 1.200448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:44:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004592153 Vs 13:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004570063 Vs 13:44:17 Magnet Current for MAIN, Imag = 120.0393 A Vtrans = 1.200450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:44:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004583958 Vs 13:44:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004578068 Vs 13:44:33 Magnet Current for MAIN, Imag = 120.0394 A Vtrans = 1.200452 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:44:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004587626 Vs 13:44:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004569777 Vs 13:44:49 Magnet Current for MAIN, Imag = 120.0393 A Vtrans = 1.200450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:44:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588204 Vs 13:45:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004564115 Vs 13:45:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004579245 +- 0.000002026 Vs 13:45:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004579245 +- 0.000002026 Vs BL = -0.04579245 +- 0.00002026 Tm 13:45:08 Position moved: 0.000000 m 13:45:08 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04579 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04579 0.00002 -0.04579 0.00000 13:45:08 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04579 0.00002 SL = -0.0457925 +- 0.0000203 Tm^2/m^n 13:45:08 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0457925 +- 0.0000203 Tm^2/m^n Remeasure 13:45:08 Magnetic Field Measurement Measuring the magnet strength... 13:45:08 Integrated Voltage Measurement... 13:45:09 Magnet Current for MAIN, Imag = 120.0391 A Vtrans = 1.200448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:45:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588523 Vs 13:45:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004582136 Vs 13:45:26 Magnet Current for MAIN, Imag = 120.0384 A Vtrans = 1.200442 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:45:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004595679 Vs 13:45:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004578207 Vs 13:45:42 Magnet Current for MAIN, Imag = 120.0387 A Vtrans = 1.200444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004585156 Vs 13:45:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004568624 Vs 13:45:58 Magnet Current for MAIN, Imag = 120.0386 A Vtrans = 1.200443 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004590161 Vs 13:46:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004582592 Vs 13:46:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004583884 +- 0.000004080 Vs 13:46:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004583884 +- 0.000004080 Vs BL = -0.04583884 +- 0.00004080 Tm 13:46:17 Position moved: 0.000000 m 13:46:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04584 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04584 0.00004 -0.04584 0.00000 13:46:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04584 0.00004 SL = -0.0458388 +- 0.0000408 Tm^2/m^n 13:46:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0458388 +- 0.0000408 Tm^2/m^n Remeasure 13:46:17 Magnetic Field Measurement Measuring the magnet strength... 13:46:17 Integrated Voltage Measurement... 13:46:17 Magnet Current for MAIN, Imag = 120.0383 A Vtrans = 1.200441 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:46:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588828 Vs 13:46:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004571620 Vs 13:46:34 Magnet Current for MAIN, Imag = 120.0394 A Vtrans = 1.200452 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:46:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004578002 Vs 13:46:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004569558 Vs 13:46:50 Magnet Current for MAIN, Imag = 120.0388 A Vtrans = 1.200446 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:46:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588274 Vs 13:47:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004569601 Vs 13:47:06 Magnet Current for MAIN, Imag = 120.0387 A Vtrans = 1.200444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:47:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004581019 Vs 13:47:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004571288 Vs 13:47:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004577274 +- 0.000002497 Vs 13:47:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004577274 +- 0.000002497 Vs BL = -0.04577274 +- 0.00002497 Tm 13:47:25 Position moved: 0.000000 m 13:47:25 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04577 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04577 0.00002 -0.04577 0.00000 13:47:25 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04577 0.00002 SL = -0.0457727 +- 0.0000250 Tm^2/m^n 13:47:25 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0457727 +- 0.0000250 Tm^2/m^n Remeasure 13:47:25 Magnetic Field Measurement Measuring the magnet strength... 13:47:25 Integrated Voltage Measurement... 13:47:26 Magnet Current for MAIN, Imag = 120.0387 A Vtrans = 1.200444 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:47:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588569 Vs 13:47:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004585664 Vs 13:47:43 Magnet Current for MAIN, Imag = 120.0391 A Vtrans = 1.200448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:47:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004592847 Vs 13:47:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004560415 Vs 13:47:59 Magnet Current for MAIN, Imag = 120.0391 A Vtrans = 1.200448 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:48:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004588302 Vs 13:48:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004554995 Vs 13:48:15 Magnet Current for MAIN, Imag = 120.0392 A Vtrans = 1.200449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:48:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004583872 Vs 13:48:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004568085 Vs 13:48:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004577844 +- 0.000005686 Vs 13:48:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004577844 +- 0.000005686 Vs BL = -0.04577844 +- 0.00005686 Tm 13:48:34 Position moved: 0.000000 m 13:48:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04578 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04578 0.00006 -0.04578 0.00000 13:48:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04578 0.00006 SL = -0.0457784 +- 0.0000569 Tm^2/m^n 13:48:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0457784 +- 0.0000569 Tm^2/m^n Remeasure 13:48:34 Magnetic Field Measurement Measuring the magnet strength... 13:48:34 Integrated Voltage Measurement... 13:48:35 Magnet Current for MAIN, Imag = 120.0389 A Vtrans = 1.200447 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:48:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004590457 Vs 13:48:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004571759 Vs 13:48:52 Magnet Current for MAIN, Imag = 120.0392 A Vtrans = 1.200449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:48:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004584506 Vs 13:49:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004581472 Vs 13:49:08 Magnet Current for MAIN, Imag = 120.0393 A Vtrans = 1.200450 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:49:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004597450 Vs 13:49:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004587319 Vs 13:49:24 Magnet Current for MAIN, Imag = 120.0392 A Vtrans = 1.200449 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:49:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004581364 Vs 13:49:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004632481 Vs 13:49:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004590851 +- 0.000010215 Vs 13:49:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004590851 +- 0.000010215 Vs BL = -0.04590851 +- 0.00010215 Tm 13:49:43 Position moved: 0.000000 m 13:49:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04591 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04591 0.00010 -0.04591 0.00000 13:49:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04591 0.00010 SL = -0.0459085 +- 0.0001021 Tm^2/m^n 13:49:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459085 +- 0.0001021 Tm^2/m^n 13:49:46 Position moved: 0.000000 m 13:49:46 Magnet system MAIN current ramping to 135.0000 A... 13:49:58 Magnet Current for MAIN, Imag = 134.9936 A Vtrans = 1.349994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:49:59 MAIN (V) Voltage Measurement, V = 5.344825 V 13:50:02 Temperature Measurement, Probe Number = 0, T = 26.026000 C 13:50:03 Temperature Measurement, Probe Number = 1, T = 27.666000 C 13:50:03 Temperature Measurement, Probe Number = 2, T = 28.215000 C 13:50:04 Temperature Measurement, Probe Number = 3, T = 28.829000 C 13:50:04 Temperature Measurement, Probe Number = 4, T = 29.855000 C 13:50:05 Temperature Measurement, Probe Number = 5, T = 25.028000 C 13:50:06 Sensor Voltage Measurement, Sensor Number = 0, V = 2.645525 V 13:50:06 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645525 (V, A, ohm, ...), Measured Value = 123.414383 (C, atm, Hz, ...) 13:50:06 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155352 V 13:50:06 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155352 (V, A, ohm, ...), Measured Value = 11.651430 (C, atm, Hz, ...) 13:50:06 Magnet Test Parameter Measurements P0 = MAIN, Value = 134.99 P1 = MAIN (V), Value = 5.34 P2 = Yoke, Value = 26.03 P3 = Bottom Coil, Value = 27.67 P4 = Top Coil, Value = 28.21 P5 = Water In, Value = 28.83 P6 = Water Out, Value = 29.86 P7 = Ambient, Value = 25.03 P8 = Supply Pres(psi), Value = 123.41 P9 = Return Pres(psi), Value = 11.65 13:50:06 Magnetic Field Measurement Measuring the magnet strength... 13:50:06 Integrated Voltage Measurement... 13:50:07 Magnet Current for MAIN, Imag = 134.9939 A Vtrans = 1.349996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:50:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005161471 Vs 13:50:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005125922 Vs 13:50:24 Magnet Current for MAIN, Imag = 134.9942 A Vtrans = 1.350000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:50:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005160670 Vs 13:50:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005132770 Vs 13:50:40 Magnet Current for MAIN, Imag = 134.9945 A Vtrans = 1.350002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:50:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005148909 Vs 13:50:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005144981 Vs 13:50:56 Magnet Current for MAIN, Imag = 134.9944 A Vtrans = 1.350001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:51:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005158705 Vs 13:51:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005135274 Vs 13:51:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005146088 +- 0.000001385 Vs 13:51:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005146088 +- 0.000001385 Vs BL = -0.05146088 +- 0.00001385 Tm 13:51:15 Position moved: 0.000000 m 13:51:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05146 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05146 0.00001 -0.05146 0.00000 13:51:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05146 0.00001 SL = -0.0514609 +- 0.0000138 Tm^2/m^n 13:51:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0514609 +- 0.0000138 Tm^2/m^n Remeasure 13:51:15 Magnetic Field Measurement Measuring the magnet strength... 13:51:15 Integrated Voltage Measurement... 13:51:16 Magnet Current for MAIN, Imag = 134.9937 A Vtrans = 1.349995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:51:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005156454 Vs 13:51:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005127398 Vs 13:51:33 Magnet Current for MAIN, Imag = 134.9942 A Vtrans = 1.350000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:51:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005157249 Vs 13:51:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005155946 Vs 13:51:49 Magnet Current for MAIN, Imag = 134.9936 A Vtrans = 1.349994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:51:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005159636 Vs 13:52:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005142697 Vs 13:52:04 Magnet Current for MAIN, Imag = 134.9934 A Vtrans = 1.349991 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:52:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005155623 Vs 13:52:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005141399 Vs 13:52:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005149550 +- 0.000005279 Vs 13:52:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005149550 +- 0.000005279 Vs BL = -0.05149550 +- 0.00005279 Tm 13:52:23 Position moved: 0.000000 m 13:52:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05150 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05150 0.00005 -0.05150 0.00000 13:52:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05150 0.00005 SL = -0.0514955 +- 0.0000528 Tm^2/m^n 13:52:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0514955 +- 0.0000528 Tm^2/m^n Remeasure 13:52:23 Magnetic Field Measurement Measuring the magnet strength... 13:52:23 Integrated Voltage Measurement... 13:52:24 Magnet Current for MAIN, Imag = 134.9937 A Vtrans = 1.349995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:52:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005148655 Vs 13:52:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005158941 Vs 13:52:41 Magnet Current for MAIN, Imag = 134.9936 A Vtrans = 1.349994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:52:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005147339 Vs 13:52:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005116833 Vs 13:52:57 Magnet Current for MAIN, Imag = 134.9940 A Vtrans = 1.349997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005151636 Vs 13:53:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005139099 Vs 13:53:13 Magnet Current for MAIN, Imag = 134.9940 A Vtrans = 1.349997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:53:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005165887 Vs 13:53:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005151379 Vs 13:53:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005147471 +- 0.000010072 Vs 13:53:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005147471 +- 0.000010072 Vs BL = -0.05147471 +- 0.00010072 Tm 13:53:32 Position moved: 0.000000 m 13:53:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05147 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05147 0.00010 -0.05147 0.00000 13:53:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05147 0.00010 SL = -0.0514747 +- 0.0001007 Tm^2/m^n 13:53:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0514747 +- 0.0001007 Tm^2/m^n Remeasure 13:53:32 Magnetic Field Measurement Measuring the magnet strength... 13:53:32 Integrated Voltage Measurement... 13:53:33 Magnet Current for MAIN, Imag = 134.9937 A Vtrans = 1.349995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:53:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005155098 Vs 13:53:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005161825 Vs 13:53:50 Magnet Current for MAIN, Imag = 134.9939 A Vtrans = 1.349996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:53:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005155269 Vs 13:54:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005163250 Vs 13:54:06 Magnet Current for MAIN, Imag = 134.9939 A Vtrans = 1.349996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:54:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005156644 Vs 13:54:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005146906 Vs 13:54:22 Magnet Current for MAIN, Imag = 134.9936 A Vtrans = 1.349994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:54:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005149980 Vs 13:54:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005154228 Vs 13:54:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005155400 +- 0.000003474 Vs 13:54:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005155400 +- 0.000003474 Vs BL = -0.05155400 +- 0.00003474 Tm 13:54:41 Position moved: 0.000000 m 13:54:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05155 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05155 0.00003 -0.05155 0.00000 13:54:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05155 0.00003 SL = -0.0515540 +- 0.0000347 Tm^2/m^n 13:54:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0515540 +- 0.0000347 Tm^2/m^n 13:54:44 Position moved: 0.000000 m 13:54:44 Magnet system MAIN current ramping to 150.0000 A... 13:54:56 Magnet Current for MAIN, Imag = 150.0290 A Vtrans = 1.500347 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:54:57 MAIN (V) Voltage Measurement, V = 5.945659 V 13:55:00 Temperature Measurement, Probe Number = 0, T = 26.071000 C 13:55:01 Temperature Measurement, Probe Number = 1, T = 27.854000 C 13:55:02 Temperature Measurement, Probe Number = 2, T = 28.369000 C 13:55:02 Temperature Measurement, Probe Number = 3, T = 28.839000 C 13:55:03 Temperature Measurement, Probe Number = 4, T = 30.128000 C 13:55:03 Temperature Measurement, Probe Number = 5, T = 24.910000 C 13:55:04 Sensor Voltage Measurement, Sensor Number = 0, V = 2.662667 V 13:55:04 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.662667 (V, A, ohm, ...), Measured Value = 124.700010 (C, atm, Hz, ...) 13:55:05 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154273 V 13:55:05 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154273 (V, A, ohm, ...), Measured Value = 11.570512 (C, atm, Hz, ...) 13:55:05 Magnet Test Parameter Measurements P0 = MAIN, Value = 150.03 P1 = MAIN (V), Value = 5.95 P2 = Yoke, Value = 26.07 P3 = Bottom Coil, Value = 27.85 P4 = Top Coil, Value = 28.37 P5 = Water In, Value = 28.84 P6 = Water Out, Value = 30.13 P7 = Ambient, Value = 24.91 P8 = Supply Pres(psi), Value = 124.70 P9 = Return Pres(psi), Value = 11.57 13:55:05 Magnetic Field Measurement Measuring the magnet strength... 13:55:05 Integrated Voltage Measurement... 13:55:05 Magnet Current for MAIN, Imag = 150.0291 A Vtrans = 1.500348 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:55:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005725219 Vs 13:55:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005711051 Vs 13:55:22 Magnet Current for MAIN, Imag = 150.0281 A Vtrans = 1.500338 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:55:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005717216 Vs 13:55:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005702061 Vs 13:55:38 Magnet Current for MAIN, Imag = 150.0275 A Vtrans = 1.500332 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:55:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005720352 Vs 13:55:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005698603 Vs 13:55:54 Magnet Current for MAIN, Imag = 150.0271 A Vtrans = 1.500328 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:56:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005740232 Vs 13:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005719162 Vs 13:56:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005716737 +- 0.000008262 Vs 13:56:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005716737 +- 0.000008262 Vs BL = -0.05716737 +- 0.00008262 Tm 13:56:13 Position moved: 0.000000 m 13:56:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05717 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05717 0.00008 -0.05717 0.00000 13:56:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05717 0.00008 SL = -0.0571674 +- 0.0000826 Tm^2/m^n 13:56:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0571674 +- 0.0000826 Tm^2/m^n Remeasure 13:56:13 Magnetic Field Measurement Measuring the magnet strength... 13:56:13 Integrated Voltage Measurement... 13:56:14 Magnet Current for MAIN, Imag = 150.0267 A Vtrans = 1.500325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:56:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005719880 Vs 13:56:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005697732 Vs 13:56:31 Magnet Current for MAIN, Imag = 150.0257 A Vtrans = 1.500315 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:56:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005718587 Vs 13:56:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005730785 Vs 13:56:47 Magnet Current for MAIN, Imag = 150.0247 A Vtrans = 1.500305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:56:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005717639 Vs 13:57:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005722657 Vs 13:57:03 Magnet Current for MAIN, Imag = 150.0242 A Vtrans = 1.500300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:57:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005721496 Vs 13:57:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005700120 Vs 13:57:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005716112 +- 0.000006544 Vs 13:57:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005716112 +- 0.000006544 Vs BL = -0.05716112 +- 0.00006544 Tm 13:57:22 Position moved: 0.000000 m 13:57:22 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05716 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05716 0.00007 -0.05716 0.00000 13:57:22 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05716 0.00007 SL = -0.0571611 +- 0.0000654 Tm^2/m^n 13:57:22 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0571611 +- 0.0000654 Tm^2/m^n Remeasure 13:57:22 Magnetic Field Measurement Measuring the magnet strength... 13:57:22 Integrated Voltage Measurement... 13:57:23 Magnet Current for MAIN, Imag = 150.0236 A Vtrans = 1.500293 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:57:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005735556 Vs 13:57:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005717653 Vs 13:57:40 Magnet Current for MAIN, Imag = 150.0237 A Vtrans = 1.500295 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:57:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005723399 Vs 13:57:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005707332 Vs 13:57:56 Magnet Current for MAIN, Imag = 150.0226 A Vtrans = 1.500283 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:58:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005716805 Vs 13:58:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005710260 Vs 13:58:12 Magnet Current for MAIN, Imag = 150.0234 A Vtrans = 1.500291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:58:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005721828 Vs 13:58:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005721518 Vs 13:58:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005719294 +- 0.000005190 Vs 13:58:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005719294 +- 0.000005190 Vs BL = -0.05719294 +- 0.00005190 Tm 13:58:31 Position moved: 0.000000 m 13:58:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05719 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05719 0.00005 -0.05719 0.00000 13:58:31 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05719 0.00005 SL = -0.0571929 +- 0.0000519 Tm^2/m^n 13:58:31 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0571929 +- 0.0000519 Tm^2/m^n Remeasure 13:58:31 Magnetic Field Measurement Measuring the magnet strength... 13:58:31 Integrated Voltage Measurement... 13:58:32 Magnet Current for MAIN, Imag = 150.0241 A Vtrans = 1.500298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:58:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005715990 Vs 13:58:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005717694 Vs 13:58:49 Magnet Current for MAIN, Imag = 150.0250 A Vtrans = 1.500307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:58:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005730299 Vs 13:59:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005708065 Vs 13:59:05 Magnet Current for MAIN, Imag = 150.0247 A Vtrans = 1.500305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:59:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005729572 Vs 13:59:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005734203 Vs 13:59:20 Magnet Current for MAIN, Imag = 150.0260 A Vtrans = 1.500317 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:59:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005720870 Vs 13:59:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005723246 Vs 13:59:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005722492 +- 0.000005730 Vs 13:59:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005722492 +- 0.000005730 Vs BL = -0.05722492 +- 0.00005730 Tm 13:59:39 Position moved: 0.000000 m 13:59:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05722 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05722 0.00006 -0.05722 0.00000 13:59:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05722 0.00006 SL = -0.0572249 +- 0.0000573 Tm^2/m^n 13:59:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0572249 +- 0.0000573 Tm^2/m^n Remeasure 13:59:39 Magnetic Field Measurement Measuring the magnet strength... 13:59:39 Integrated Voltage Measurement... 13:59:40 Magnet Current for MAIN, Imag = 150.0265 A Vtrans = 1.500322 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 13:59:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005716702 Vs 13:59:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005717586 Vs 13:59:57 Magnet Current for MAIN, Imag = 150.0246 A Vtrans = 1.500303 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:00:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005720369 Vs 14:00:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005700829 Vs 14:00:13 Magnet Current for MAIN, Imag = 150.0250 A Vtrans = 1.500307 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:00:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005730274 Vs 14:00:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005698801 Vs 14:00:29 Magnet Current for MAIN, Imag = 150.0259 A Vtrans = 1.500316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:00:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005731396 Vs 14:00:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005697975 Vs 14:00:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005714241 +- 0.000002344 Vs 14:00:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005714241 +- 0.000002344 Vs BL = -0.05714241 +- 0.00002344 Tm 14:00:48 Position moved: 0.000000 m 14:00:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05714 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05714 0.00002 -0.05714 0.00000 14:00:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05714 0.00002 SL = -0.0571424 +- 0.0000234 Tm^2/m^n 14:00:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0571424 +- 0.0000234 Tm^2/m^n 14:00:51 Position moved: 0.000000 m 14:00:51 Magnet system MAIN current ramping to 165.0000 A... 14:01:03 Magnet Current for MAIN, Imag = 164.9750 A Vtrans = 1.649808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:01:03 MAIN (V) Voltage Measurement, V = 6.545101 V 14:01:07 Temperature Measurement, Probe Number = 0, T = 26.086000 C 14:01:07 Temperature Measurement, Probe Number = 1, T = 28.080000 C 14:01:08 Temperature Measurement, Probe Number = 2, T = 28.579000 C 14:01:09 Temperature Measurement, Probe Number = 3, T = 28.915000 C 14:01:09 Temperature Measurement, Probe Number = 4, T = 30.520000 C 14:01:10 Temperature Measurement, Probe Number = 5, T = 25.106000 C 14:01:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.663691 V 14:01:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.663691 (V, A, ohm, ...), Measured Value = 124.776803 (C, atm, Hz, ...) 14:01:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.153857 V 14:01:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.153857 (V, A, ohm, ...), Measured Value = 11.539238 (C, atm, Hz, ...) 14:01:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.98 P1 = MAIN (V), Value = 6.55 P2 = Yoke, Value = 26.09 P3 = Bottom Coil, Value = 28.08 P4 = Top Coil, Value = 28.58 P5 = Water In, Value = 28.91 P6 = Water Out, Value = 30.52 P7 = Ambient, Value = 25.11 P8 = Supply Pres(psi), Value = 124.78 P9 = Return Pres(psi), Value = 11.54 14:01:11 Magnetic Field Measurement Measuring the magnet strength... 14:01:11 Integrated Voltage Measurement... 14:01:12 Magnet Current for MAIN, Imag = 164.9743 A Vtrans = 1.649800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:01:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006273794 Vs 14:01:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006274934 Vs 14:01:29 Magnet Current for MAIN, Imag = 164.9742 A Vtrans = 1.649799 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:01:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006287825 Vs 14:01:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006298422 Vs 14:01:45 Magnet Current for MAIN, Imag = 164.9733 A Vtrans = 1.649790 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:01:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006279442 Vs 14:02:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006229076 Vs 14:02:01 Magnet Current for MAIN, Imag = 164.9725 A Vtrans = 1.649783 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:02:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006282691 Vs 14:02:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006287593 Vs 14:02:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006276722 +- 0.000014578 Vs 14:02:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006276722 +- 0.000014578 Vs BL = -0.06276722 +- 0.00014578 Tm 14:02:20 Position moved: 0.000000 m 14:02:20 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06277 0.00015 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06277 0.00015 -0.06277 0.00000 14:02:20 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06277 0.00015 SL = -0.0627672 +- 0.0001458 Tm^2/m^n 14:02:20 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0627672 +- 0.0001458 Tm^2/m^n Remeasure 14:02:20 Magnetic Field Measurement Measuring the magnet strength... 14:02:20 Integrated Voltage Measurement... 14:02:21 Magnet Current for MAIN, Imag = 164.9719 A Vtrans = 1.649776 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:02:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006299021 Vs 14:02:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006248408 Vs 14:02:38 Magnet Current for MAIN, Imag = 164.9697 A Vtrans = 1.649754 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:02:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006286085 Vs 14:02:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006278228 Vs 14:02:54 Magnet Current for MAIN, Imag = 164.9688 A Vtrans = 1.649745 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:03:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006282447 Vs 14:03:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006287612 Vs 14:03:10 Magnet Current for MAIN, Imag = 164.9688 A Vtrans = 1.649745 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:03:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006290586 Vs 14:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006324816 Vs 14:03:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006287151 +- 0.000012573 Vs 14:03:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006287151 +- 0.000012573 Vs BL = -0.06287151 +- 0.00012573 Tm 14:03:29 Position moved: 0.000000 m 14:03:29 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06287 0.00013 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06287 0.00013 -0.06287 0.00000 14:03:29 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06287 0.00013 SL = -0.0628715 +- 0.0001257 Tm^2/m^n 14:03:29 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0628715 +- 0.0001257 Tm^2/m^n Remeasure 14:03:29 Magnetic Field Measurement Measuring the magnet strength... 14:03:29 Integrated Voltage Measurement... 14:03:30 Magnet Current for MAIN, Imag = 164.9695 A Vtrans = 1.649753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:03:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006294959 Vs 14:03:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006273658 Vs 14:03:47 Magnet Current for MAIN, Imag = 164.9699 A Vtrans = 1.649757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:03:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006296162 Vs 14:04:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006281819 Vs 14:04:03 Magnet Current for MAIN, Imag = 164.9704 A Vtrans = 1.649762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:04:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006290329 Vs 14:04:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006311405 Vs 14:04:19 Magnet Current for MAIN, Imag = 164.9679 A Vtrans = 1.649736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:04:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006296290 Vs 14:04:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006273476 Vs 14:04:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006289762 +- 0.000006661 Vs 14:04:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006289762 +- 0.000006661 Vs BL = -0.06289762 +- 0.00006661 Tm 14:04:38 Position moved: 0.000000 m 14:04:38 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06290 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06290 0.00007 -0.06290 0.00000 14:04:38 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06290 0.00007 SL = -0.0628976 +- 0.0000666 Tm^2/m^n 14:04:38 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0628976 +- 0.0000666 Tm^2/m^n Remeasure 14:04:38 Magnetic Field Measurement Measuring the magnet strength... 14:04:38 Integrated Voltage Measurement... 14:04:39 Magnet Current for MAIN, Imag = 164.9683 A Vtrans = 1.649740 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:04:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006273651 Vs 14:04:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006261792 Vs 14:04:56 Magnet Current for MAIN, Imag = 164.9678 A Vtrans = 1.649735 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:05:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006299712 Vs 14:05:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006288941 Vs 14:05:12 Magnet Current for MAIN, Imag = 164.9699 A Vtrans = 1.649757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:05:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006302972 Vs 14:05:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006278903 Vs 14:05:28 Magnet Current for MAIN, Imag = 164.9688 A Vtrans = 1.649745 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:05:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006279867 Vs 14:05:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006269478 Vs 14:05:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006281915 +- 0.000011061 Vs 14:05:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006281915 +- 0.000011061 Vs BL = -0.06281915 +- 0.00011061 Tm 14:05:47 Position moved: 0.000000 m 14:05:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06282 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06282 0.00011 -0.06282 0.00000 14:05:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06282 0.00011 SL = -0.0628191 +- 0.0001106 Tm^2/m^n 14:05:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0628191 +- 0.0001106 Tm^2/m^n Remeasure 14:05:47 Magnetic Field Measurement Measuring the magnet strength... 14:05:47 Integrated Voltage Measurement... 14:05:48 Magnet Current for MAIN, Imag = 164.9689 A Vtrans = 1.649747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:05:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006274753 Vs 14:06:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006256786 Vs 14:06:05 Magnet Current for MAIN, Imag = 164.9669 A Vtrans = 1.649727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006298886 Vs 14:06:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006284878 Vs 14:06:21 Magnet Current for MAIN, Imag = 164.9655 A Vtrans = 1.649713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:06:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006295544 Vs 14:06:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006275574 Vs 14:06:37 Magnet Current for MAIN, Imag = 164.9647 A Vtrans = 1.649704 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006280454 Vs 14:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006295598 Vs 14:06:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006282809 +- 0.000010093 Vs 14:06:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006282809 +- 0.000010093 Vs BL = -0.06282809 +- 0.00010093 Tm 14:06:56 Position moved: 0.000000 m 14:06:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06283 0.00010 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06283 0.00010 -0.06283 0.00000 14:06:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06283 0.00010 SL = -0.0628281 +- 0.0001009 Tm^2/m^n 14:06:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0628281 +- 0.0001009 Tm^2/m^n 14:06:59 Position moved: 0.000000 m 14:06:59 Magnet system MAIN current ramping to 180.0000 A... 14:07:11 Magnet Current for MAIN, Imag = 179.9955 A Vtrans = 1.800013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:07:11 MAIN (V) Voltage Measurement, V = 7.146035 V 14:07:15 Temperature Measurement, Probe Number = 0, T = 26.097000 C 14:07:16 Temperature Measurement, Probe Number = 1, T = 28.200000 C 14:07:16 Temperature Measurement, Probe Number = 2, T = 28.488000 C 14:07:17 Temperature Measurement, Probe Number = 3, T = 28.818000 C 14:07:17 Temperature Measurement, Probe Number = 4, T = 30.741000 C 14:07:18 Temperature Measurement, Probe Number = 5, T = 25.120000 C 14:07:19 Sensor Voltage Measurement, Sensor Number = 0, V = 2.627718 V 14:07:19 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.627718 (V, A, ohm, ...), Measured Value = 122.078842 (C, atm, Hz, ...) 14:07:19 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156477 V 14:07:19 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156477 (V, A, ohm, ...), Measured Value = 11.735805 (C, atm, Hz, ...) 14:07:19 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.00 P1 = MAIN (V), Value = 7.15 P2 = Yoke, Value = 26.10 P3 = Bottom Coil, Value = 28.20 P4 = Top Coil, Value = 28.49 P5 = Water In, Value = 28.82 P6 = Water Out, Value = 30.74 P7 = Ambient, Value = 25.12 P8 = Supply Pres(psi), Value = 122.08 P9 = Return Pres(psi), Value = 11.74 14:07:19 Magnetic Field Measurement Measuring the magnet strength... 14:07:19 Integrated Voltage Measurement... 14:07:20 Magnet Current for MAIN, Imag = 179.9955 A Vtrans = 1.800013 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:07:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006860722 Vs 14:07:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006855892 Vs 14:07:37 Magnet Current for MAIN, Imag = 179.9948 A Vtrans = 1.800005 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:07:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006854128 Vs 14:07:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006842006 Vs 14:07:53 Magnet Current for MAIN, Imag = 179.9942 A Vtrans = 1.799999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:08:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006853297 Vs 14:08:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006838609 Vs 14:08:09 Magnet Current for MAIN, Imag = 179.9939 A Vtrans = 1.799996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:08:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006858372 Vs 14:08:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006815570 Vs 14:08:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006847325 +- 0.000007587 Vs 14:08:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006847325 +- 0.000007587 Vs BL = -0.06847325 +- 0.00007587 Tm 14:08:28 Position moved: 0.000000 m 14:08:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06847 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06847 0.00008 -0.06847 0.00000 14:08:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06847 0.00008 SL = -0.0684732 +- 0.0000759 Tm^2/m^n 14:08:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0684732 +- 0.0000759 Tm^2/m^n Remeasure 14:08:28 Magnetic Field Measurement Measuring the magnet strength... 14:08:28 Integrated Voltage Measurement... 14:08:29 Magnet Current for MAIN, Imag = 179.9935 A Vtrans = 1.799993 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:08:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006859903 Vs 14:08:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006839618 Vs 14:08:46 Magnet Current for MAIN, Imag = 179.9933 A Vtrans = 1.799990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:08:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006866315 Vs 14:09:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006841254 Vs 14:09:02 Magnet Current for MAIN, Imag = 179.9940 A Vtrans = 1.799998 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:09:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006851598 Vs 14:09:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006830837 Vs 14:09:18 Magnet Current for MAIN, Imag = 179.9938 A Vtrans = 1.799995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:09:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006850872 Vs 14:09:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006828140 Vs 14:09:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006846067 +- 0.000005911 Vs 14:09:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006846067 +- 0.000005911 Vs BL = -0.06846067 +- 0.00005911 Tm 14:09:37 Position moved: 0.000000 m 14:09:37 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06846 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06846 0.00006 -0.06846 0.00000 14:09:37 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06846 0.00006 SL = -0.0684607 +- 0.0000591 Tm^2/m^n 14:09:37 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0684607 +- 0.0000591 Tm^2/m^n Remeasure 14:09:37 Magnetic Field Measurement Measuring the magnet strength... 14:09:37 Integrated Voltage Measurement... 14:09:38 Magnet Current for MAIN, Imag = 179.9954 A Vtrans = 1.800011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:09:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006863484 Vs 14:09:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006871010 Vs 14:09:55 Magnet Current for MAIN, Imag = 179.9952 A Vtrans = 1.800009 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006865315 Vs 14:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006839873 Vs 14:10:11 Magnet Current for MAIN, Imag = 179.9953 A Vtrans = 1.800010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:10:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006861495 Vs 14:10:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006844707 Vs 14:10:27 Magnet Current for MAIN, Imag = 179.9947 A Vtrans = 1.800004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:10:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006840344 Vs 14:10:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006830667 Vs 14:10:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006852112 +- 0.000011248 Vs 14:10:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006852112 +- 0.000011248 Vs BL = -0.06852112 +- 0.00011248 Tm 14:10:46 Position moved: 0.000000 m 14:10:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06852 0.00011 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06852 0.00011 -0.06852 0.00000 14:10:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06852 0.00011 SL = -0.0685211 +- 0.0001125 Tm^2/m^n 14:10:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0685211 +- 0.0001125 Tm^2/m^n Remeasure 14:10:46 Magnetic Field Measurement Measuring the magnet strength... 14:10:46 Integrated Voltage Measurement... 14:10:47 Magnet Current for MAIN, Imag = 179.9929 A Vtrans = 1.799986 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006852291 Vs 14:11:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006853021 Vs 14:11:04 Magnet Current for MAIN, Imag = 179.9920 A Vtrans = 1.799978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006857200 Vs 14:11:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006847422 Vs 14:11:20 Magnet Current for MAIN, Imag = 179.9912 A Vtrans = 1.799969 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006862465 Vs 14:11:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006818997 Vs 14:11:36 Magnet Current for MAIN, Imag = 179.9919 A Vtrans = 1.799976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:11:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006859248 Vs 14:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006837540 Vs 14:11:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006848523 +- 0.000004800 Vs 14:11:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006848523 +- 0.000004800 Vs BL = -0.06848523 +- 0.00004800 Tm 14:11:55 Position moved: 0.000000 m 14:11:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06849 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06849 0.00005 -0.06849 0.00000 14:11:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06849 0.00005 SL = -0.0684852 +- 0.0000480 Tm^2/m^n 14:11:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0684852 +- 0.0000480 Tm^2/m^n Remeasure 14:11:55 Magnetic Field Measurement Measuring the magnet strength... 14:11:55 Integrated Voltage Measurement... 14:11:56 Magnet Current for MAIN, Imag = 179.9909 A Vtrans = 1.799967 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:12:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006853336 Vs 14:12:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006857784 Vs 14:12:13 Magnet Current for MAIN, Imag = 179.9910 A Vtrans = 1.799968 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006871219 Vs 14:12:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006847457 Vs 14:12:29 Magnet Current for MAIN, Imag = 179.9914 A Vtrans = 1.799971 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:12:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006865012 Vs 14:12:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006865518 Vs 14:12:45 Magnet Current for MAIN, Imag = 179.9915 A Vtrans = 1.799973 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:12:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006868545 Vs 14:13:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006874722 Vs 14:13:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006862949 +- 0.000006091 Vs 14:13:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006862949 +- 0.000006091 Vs BL = -0.06862949 +- 0.00006091 Tm 14:13:04 Position moved: 0.000000 m 14:13:04 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06863 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06863 0.00006 -0.06863 0.00000 14:13:04 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06863 0.00006 SL = -0.0686295 +- 0.0000609 Tm^2/m^n 14:13:04 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0686295 +- 0.0000609 Tm^2/m^n 14:13:06 Position moved: 0.000000 m 14:13:06 Magnet system MAIN current ramping to 185.0000 A... 14:13:18 Magnet Current for MAIN, Imag = 185.0249 A Vtrans = 1.850306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:13:19 MAIN (V) Voltage Measurement, V = 7.348779 V 14:13:22 Temperature Measurement, Probe Number = 0, T = 26.146000 C 14:13:23 Temperature Measurement, Probe Number = 1, T = 28.362000 C 14:13:23 Temperature Measurement, Probe Number = 2, T = 28.856000 C 14:13:24 Temperature Measurement, Probe Number = 3, T = 28.768000 C 14:13:24 Temperature Measurement, Probe Number = 4, T = 31.045000 C 14:13:25 Temperature Measurement, Probe Number = 5, T = 25.199000 C 14:13:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656396 V 14:13:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656396 (V, A, ohm, ...), Measured Value = 124.229700 (C, atm, Hz, ...) 14:13:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158832 V 14:13:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158832 (V, A, ohm, ...), Measured Value = 11.912430 (C, atm, Hz, ...) 14:13:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 185.02 P1 = MAIN (V), Value = 7.35 P2 = Yoke, Value = 26.15 P3 = Bottom Coil, Value = 28.36 P4 = Top Coil, Value = 28.86 P5 = Water In, Value = 28.77 P6 = Water Out, Value = 31.05 P7 = Ambient, Value = 25.20 P8 = Supply Pres(psi), Value = 124.23 P9 = Return Pres(psi), Value = 11.91 14:13:26 Magnetic Field Measurement Measuring the magnet strength... 14:13:26 Integrated Voltage Measurement... 14:13:27 Magnet Current for MAIN, Imag = 185.0249 A Vtrans = 1.850306 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:13:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007049855 Vs 14:13:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007053110 Vs 14:13:44 Magnet Current for MAIN, Imag = 185.0253 A Vtrans = 1.850310 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007047314 Vs 14:13:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007023285 Vs 14:14:00 Magnet Current for MAIN, Imag = 185.0242 A Vtrans = 1.850299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:14:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007037509 Vs 14:14:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007023449 Vs 14:14:16 Magnet Current for MAIN, Imag = 185.0240 A Vtrans = 1.850298 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:14:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007050548 Vs 14:14:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007029013 Vs 14:14:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007039260 +- 0.000007786 Vs 14:14:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007039260 +- 0.000007786 Vs BL = -0.07039260 +- 0.00007786 Tm 14:14:35 Position moved: 0.000000 m 14:14:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07039 0.00008 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07039 0.00008 -0.07039 0.00000 14:14:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07039 0.00008 SL = -0.0703926 +- 0.0000779 Tm^2/m^n 14:14:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0703926 +- 0.0000779 Tm^2/m^n Remeasure 14:14:35 Magnetic Field Measurement Measuring the magnet strength... 14:14:35 Integrated Voltage Measurement... 14:14:36 Magnet Current for MAIN, Imag = 185.0250 A Vtrans = 1.850308 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:14:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007050290 Vs 14:14:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007023135 Vs 14:14:52 Magnet Current for MAIN, Imag = 185.0242 A Vtrans = 1.850299 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:15:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007034518 Vs 14:15:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007063187 Vs 14:15:08 Magnet Current for MAIN, Imag = 185.0239 A Vtrans = 1.850297 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:15:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007049364 Vs 14:15:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007039948 Vs 14:15:24 Magnet Current for MAIN, Imag = 185.0243 A Vtrans = 1.850300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:15:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007056415 Vs 14:15:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007010185 Vs 14:15:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007040880 +- 0.000006177 Vs 14:15:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007040880 +- 0.000006177 Vs BL = -0.07040880 +- 0.00006177 Tm 14:15:43 Position moved: 0.000000 m 14:15:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07041 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07041 0.00006 -0.07041 0.00000 14:15:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07041 0.00006 SL = -0.0704088 +- 0.0000618 Tm^2/m^n 14:15:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0704088 +- 0.0000618 Tm^2/m^n Remeasure 14:15:43 Magnetic Field Measurement Measuring the magnet strength... 14:15:43 Integrated Voltage Measurement... 14:15:44 Magnet Current for MAIN, Imag = 185.0243 A Vtrans = 1.850300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:15:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007058072 Vs 14:16:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007049819 Vs 14:16:01 Magnet Current for MAIN, Imag = 185.0243 A Vtrans = 1.850300 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:16:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007046290 Vs 14:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007026943 Vs 14:16:17 Magnet Current for MAIN, Imag = 185.0244 A Vtrans = 1.850301 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:16:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007039518 Vs 14:16:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007031658 Vs 14:16:33 Magnet Current for MAIN, Imag = 185.0245 A Vtrans = 1.850303 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:16:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007046227 Vs 14:16:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007031294 Vs 14:16:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007041227 +- 0.000007431 Vs 14:16:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007041227 +- 0.000007431 Vs BL = -0.07041227 +- 0.00007431 Tm 14:16:52 Position moved: 0.000000 m 14:16:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07041 0.00007 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07041 0.00007 -0.07041 0.00000 14:16:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07041 0.00007 SL = -0.0704123 +- 0.0000743 Tm^2/m^n 14:16:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0704123 +- 0.0000743 Tm^2/m^n Remeasure 14:16:52 Magnetic Field Measurement Measuring the magnet strength... 14:16:52 Integrated Voltage Measurement... 14:16:53 Magnet Current for MAIN, Imag = 185.0248 A Vtrans = 1.850305 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:17:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007026833 Vs 14:17:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007038981 Vs 14:17:10 Magnet Current for MAIN, Imag = 185.0252 A Vtrans = 1.850309 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:17:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007039520 Vs 14:17:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007025272 Vs 14:17:26 Magnet Current for MAIN, Imag = 185.0257 A Vtrans = 1.850314 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:17:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007048332 Vs 14:17:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007030446 Vs 14:17:42 Magnet Current for MAIN, Imag = 185.0267 A Vtrans = 1.850324 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:17:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007043670 Vs 14:17:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007036638 Vs 14:17:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007036211 +- 0.000003575 Vs 14:17:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007036211 +- 0.000003575 Vs BL = -0.07036211 +- 0.00003575 Tm 14:18:01 Position moved: 0.000000 m 14:18:01 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07036 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07036 0.00004 -0.07036 0.00000 14:18:01 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07036 0.00004 SL = -0.0703621 +- 0.0000357 Tm^2/m^n 14:18:01 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0703621 +- 0.0000357 Tm^2/m^n Remeasure 14:18:01 Magnetic Field Measurement Measuring the magnet strength... 14:18:01 Integrated Voltage Measurement... 14:18:02 Magnet Current for MAIN, Imag = 185.0259 A Vtrans = 1.850316 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:18:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007045145 Vs 14:18:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007017262 Vs 14:18:19 Magnet Current for MAIN, Imag = 185.0255 A Vtrans = 1.850313 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:18:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007040714 Vs 14:18:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007041614 Vs 14:18:35 Magnet Current for MAIN, Imag = 185.0268 A Vtrans = 1.850325 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:18:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007046924 Vs 14:18:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007039073 Vs 14:18:51 Magnet Current for MAIN, Imag = 185.0273 A Vtrans = 1.850330 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:18:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007057172 Vs 14:19:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.007016996 Vs 14:19:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.007038113 +- 0.000004527 Vs 14:19:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.007038113 +- 0.000004527 Vs BL = -0.07038113 +- 0.00004527 Tm 14:19:10 Position moved: 0.000000 m 14:19:10 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.07038 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.07038 0.00005 -0.07038 0.00000 14:19:10 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.07038 0.00005 SL = -0.0703811 +- 0.0000453 Tm^2/m^n 14:19:10 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0703811 +- 0.0000453 Tm^2/m^n 14:19:13 Position moved: 0.000000 m 14:19:13 Magnet system MAIN current ramping to 180.0000 A... 14:19:24 Magnet Current for MAIN, Imag = 179.9953 A Vtrans = 1.800010 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:19:25 MAIN (V) Voltage Measurement, V = 7.145893 V 14:19:28 Temperature Measurement, Probe Number = 0, T = 26.138000 C 14:19:29 Temperature Measurement, Probe Number = 1, T = 28.346000 C 14:19:30 Temperature Measurement, Probe Number = 2, T = 28.812000 C 14:19:30 Temperature Measurement, Probe Number = 3, T = 28.655000 C 14:19:31 Temperature Measurement, Probe Number = 4, T = 30.958000 C 14:19:31 Temperature Measurement, Probe Number = 5, T = 24.754000 C 14:19:32 Sensor Voltage Measurement, Sensor Number = 0, V = 2.653821 V 14:19:32 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.653821 (V, A, ohm, ...), Measured Value = 124.036590 (C, atm, Hz, ...) 14:19:32 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157310 V 14:19:33 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157310 (V, A, ohm, ...), Measured Value = 11.798273 (C, atm, Hz, ...) 14:19:33 Magnet Test Parameter Measurements P0 = MAIN, Value = 180.00 P1 = MAIN (V), Value = 7.15 P2 = Yoke, Value = 26.14 P3 = Bottom Coil, Value = 28.35 P4 = Top Coil, Value = 28.81 P5 = Water In, Value = 28.66 P6 = Water Out, Value = 30.96 P7 = Ambient, Value = 24.75 P8 = Supply Pres(psi), Value = 124.04 P9 = Return Pres(psi), Value = 11.80 14:19:33 Magnetic Field Measurement Measuring the magnet strength... 14:19:33 Integrated Voltage Measurement... 14:19:33 Magnet Current for MAIN, Imag = 179.9944 A Vtrans = 1.800001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:19:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006849995 Vs 14:19:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006830394 Vs 14:19:50 Magnet Current for MAIN, Imag = 179.9947 A Vtrans = 1.800004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:19:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006866465 Vs 14:20:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006835143 Vs 14:20:06 Magnet Current for MAIN, Imag = 179.9963 A Vtrans = 1.800020 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:20:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006866190 Vs 14:20:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006847529 Vs 14:20:22 Magnet Current for MAIN, Imag = 179.9954 A Vtrans = 1.800011 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:20:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006857089 Vs 14:20:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006845459 Vs 14:20:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006849783 +- 0.000006027 Vs 14:20:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006849783 +- 0.000006027 Vs BL = -0.06849783 +- 0.00006027 Tm 14:20:41 Position moved: 0.000000 m 14:20:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06850 0.00006 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06850 0.00006 -0.06850 0.00000 14:20:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06850 0.00006 SL = -0.0684978 +- 0.0000603 Tm^2/m^n 14:20:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0684978 +- 0.0000603 Tm^2/m^n Remeasure 14:20:41 Magnetic Field Measurement Measuring the magnet strength... 14:20:41 Integrated Voltage Measurement... 14:20:42 Magnet Current for MAIN, Imag = 179.9975 A Vtrans = 1.800033 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:20:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006860674 Vs 14:20:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006837966 Vs 14:20:59 Magnet Current for MAIN, Imag = 179.9964 A Vtrans = 1.800021 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:21:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006852508 Vs 14:21:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006849721 Vs 14:21:15 Magnet Current for MAIN, Imag = 179.9987 A Vtrans = 1.800044 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:21:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006859596 Vs 14:21:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006836091 Vs 14:21:31 Magnet Current for MAIN, Imag = 179.9972 A Vtrans = 1.800029 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:21:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006854060 Vs 14:21:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006850331 Vs 14:21:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006850118 +- 0.000001667 Vs 14:21:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006850118 +- 0.000001667 Vs BL = -0.06850118 +- 0.00001667 Tm 14:21:50 Position moved: 0.000000 m 14:21:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06850 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06850 0.00002 -0.06850 0.00000 14:21:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06850 0.00002 SL = -0.0685012 +- 0.0000167 Tm^2/m^n 14:21:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0685012 +- 0.0000167 Tm^2/m^n 14:21:53 Position moved: 0.000000 m 14:21:53 Magnet system MAIN current ramping to 165.0000 A... 14:22:05 Magnet Current for MAIN, Imag = 164.9607 A Vtrans = 1.649664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:22:06 MAIN (V) Voltage Measurement, V = 6.542590 V 14:22:09 Temperature Measurement, Probe Number = 0, T = 26.119000 C 14:22:10 Temperature Measurement, Probe Number = 1, T = 28.190000 C 14:22:11 Temperature Measurement, Probe Number = 2, T = 28.645000 C 14:22:11 Temperature Measurement, Probe Number = 3, T = 28.631000 C 14:22:12 Temperature Measurement, Probe Number = 4, T = 30.804000 C 14:22:12 Temperature Measurement, Probe Number = 5, T = 24.706000 C 14:22:13 Sensor Voltage Measurement, Sensor Number = 0, V = 2.640997 V 14:22:13 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.640997 (V, A, ohm, ...), Measured Value = 123.074805 (C, atm, Hz, ...) 14:22:14 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158235 V 14:22:14 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158235 (V, A, ohm, ...), Measured Value = 11.867662 (C, atm, Hz, ...) 14:22:14 Magnet Test Parameter Measurements P0 = MAIN, Value = 164.96 P1 = MAIN (V), Value = 6.54 P2 = Yoke, Value = 26.12 P3 = Bottom Coil, Value = 28.19 P4 = Top Coil, Value = 28.64 P5 = Water In, Value = 28.63 P6 = Water Out, Value = 30.80 P7 = Ambient, Value = 24.71 P8 = Supply Pres(psi), Value = 123.07 P9 = Return Pres(psi), Value = 11.87 14:22:14 Magnetic Field Measurement Measuring the magnet strength... 14:22:14 Integrated Voltage Measurement... 14:22:14 Magnet Current for MAIN, Imag = 164.9604 A Vtrans = 1.649662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:22:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006308517 Vs 14:22:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006289304 Vs 14:22:32 Magnet Current for MAIN, Imag = 164.9618 A Vtrans = 1.649675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:22:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006300962 Vs 14:22:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006281314 Vs 14:22:48 Magnet Current for MAIN, Imag = 164.9620 A Vtrans = 1.649678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:22:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006297468 Vs 14:23:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006285565 Vs 14:23:04 Magnet Current for MAIN, Imag = 164.9615 A Vtrans = 1.649673 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:23:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006298965 Vs 14:23:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006285377 Vs 14:23:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006293434 +- 0.000003183 Vs 14:23:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006293434 +- 0.000003183 Vs BL = -0.06293434 +- 0.00003183 Tm 14:23:23 Position moved: 0.000000 m 14:23:23 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06293 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06293 0.00003 -0.06293 0.00000 14:23:23 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06293 0.00003 SL = -0.0629343 +- 0.0000318 Tm^2/m^n 14:23:23 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0629343 +- 0.0000318 Tm^2/m^n Remeasure 14:23:23 Magnetic Field Measurement Measuring the magnet strength... 14:23:23 Integrated Voltage Measurement... 14:23:23 Magnet Current for MAIN, Imag = 164.9619 A Vtrans = 1.649677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:23:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006305093 Vs 14:23:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006285349 Vs 14:23:40 Magnet Current for MAIN, Imag = 164.9618 A Vtrans = 1.649675 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:23:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006311285 Vs 14:23:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006283965 Vs 14:23:56 Magnet Current for MAIN, Imag = 164.9610 A Vtrans = 1.649668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:24:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006298879 Vs 14:24:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006285933 Vs 14:24:12 Magnet Current for MAIN, Imag = 164.9607 A Vtrans = 1.649664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:24:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006300753 Vs 14:24:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006293066 Vs 14:24:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006295540 +- 0.000002009 Vs 14:24:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006295540 +- 0.000002009 Vs BL = -0.06295540 +- 0.00002009 Tm 14:24:32 Position moved: 0.000000 m 14:24:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06296 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06296 0.00002 -0.06296 0.00000 14:24:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06296 0.00002 SL = -0.0629554 +- 0.0000201 Tm^2/m^n 14:24:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0629554 +- 0.0000201 Tm^2/m^n Remeasure 14:24:32 Magnetic Field Measurement Measuring the magnet strength... 14:24:32 Integrated Voltage Measurement... 14:24:32 Magnet Current for MAIN, Imag = 164.9617 A Vtrans = 1.649674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:24:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006301214 Vs 14:24:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006280367 Vs 14:24:49 Magnet Current for MAIN, Imag = 164.9617 A Vtrans = 1.649674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:24:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006302673 Vs 14:25:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006279486 Vs 14:25:05 Magnet Current for MAIN, Imag = 164.9604 A Vtrans = 1.649662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:25:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006293886 Vs 14:25:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006290273 Vs 14:25:21 Magnet Current for MAIN, Imag = 164.9623 A Vtrans = 1.649680 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:25:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006295725 Vs 14:25:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.006292560 Vs 14:25:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.006292023 +- 0.000001314 Vs 14:25:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.006292023 +- 0.000001314 Vs BL = -0.06292023 +- 0.00001314 Tm 14:25:41 Position moved: 0.000000 m 14:25:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.06292 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.06292 0.00001 -0.06292 0.00000 14:25:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.06292 0.00001 SL = -0.0629202 +- 0.0000131 Tm^2/m^n 14:25:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0629202 +- 0.0000131 Tm^2/m^n 14:25:44 Position moved: 0.000000 m 14:25:44 Magnet system MAIN current ramping to 150.0000 A... 14:25:56 Magnet Current for MAIN, Imag = 150.0087 A Vtrans = 1.500145 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:25:56 MAIN (V) Voltage Measurement, V = 5.944829 V 14:26:00 Temperature Measurement, Probe Number = 0, T = 26.158000 C 14:26:00 Temperature Measurement, Probe Number = 1, T = 28.105000 C 14:26:01 Temperature Measurement, Probe Number = 2, T = 28.420000 C 14:26:02 Temperature Measurement, Probe Number = 3, T = 28.704000 C 14:26:02 Temperature Measurement, Probe Number = 4, T = 30.557000 C 14:26:03 Temperature Measurement, Probe Number = 5, T = 24.828000 C 14:26:03 Sensor Voltage Measurement, Sensor Number = 0, V = 2.659368 V 14:26:03 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.659368 (V, A, ohm, ...), Measured Value = 124.452585 (C, atm, Hz, ...) 14:26:04 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156321 V 14:26:04 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156321 (V, A, ohm, ...), Measured Value = 11.724098 (C, atm, Hz, ...) 14:26:04 Magnet Test Parameter Measurements P0 = MAIN, Value = 150.01 P1 = MAIN (V), Value = 5.94 P2 = Yoke, Value = 26.16 P3 = Bottom Coil, Value = 28.11 P4 = Top Coil, Value = 28.42 P5 = Water In, Value = 28.70 P6 = Water Out, Value = 30.56 P7 = Ambient, Value = 24.83 P8 = Supply Pres(psi), Value = 124.45 P9 = Return Pres(psi), Value = 11.72 14:26:04 Magnetic Field Measurement Measuring the magnet strength... 14:26:04 Integrated Voltage Measurement... 14:26:05 Magnet Current for MAIN, Imag = 150.0094 A Vtrans = 1.500151 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:26:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005738083 Vs 14:26:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005721462 Vs 14:26:22 Magnet Current for MAIN, Imag = 150.0081 A Vtrans = 1.500139 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:26:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005736495 Vs 14:26:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005718948 Vs 14:26:38 Magnet Current for MAIN, Imag = 150.0094 A Vtrans = 1.500151 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:26:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005738602 Vs 14:26:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005721877 Vs 14:26:54 Magnet Current for MAIN, Imag = 150.0080 A Vtrans = 1.500137 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:27:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005724052 Vs 14:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005731882 Vs 14:27:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005728925 +- 0.000001097 Vs 14:27:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005728925 +- 0.000001097 Vs BL = -0.05728925 +- 0.00001097 Tm 14:27:13 Position moved: 0.000000 m 14:27:13 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05729 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05729 0.00001 -0.05729 0.00000 14:27:13 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05729 0.00001 SL = -0.0572893 +- 0.0000110 Tm^2/m^n 14:27:13 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0572893 +- 0.0000110 Tm^2/m^n 14:27:15 Position moved: 0.000000 m 14:27:15 Magnet system MAIN current ramping to 135.0000 A... 14:27:28 Magnet Current for MAIN, Imag = 134.9721 A Vtrans = 1.349779 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:27:28 MAIN (V) Voltage Measurement, V = 5.344055 V 14:27:32 Temperature Measurement, Probe Number = 0, T = 26.201000 C 14:27:32 Temperature Measurement, Probe Number = 1, T = 28.063000 C 14:27:33 Temperature Measurement, Probe Number = 2, T = 28.436000 C 14:27:34 Temperature Measurement, Probe Number = 3, T = 28.733000 C 14:27:34 Temperature Measurement, Probe Number = 4, T = 30.390000 C 14:27:35 Temperature Measurement, Probe Number = 5, T = 24.868000 C 14:27:35 Sensor Voltage Measurement, Sensor Number = 0, V = 2.647620 V 14:27:35 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.647620 (V, A, ohm, ...), Measured Value = 123.571522 (C, atm, Hz, ...) 14:27:36 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157385 V 14:27:36 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157385 (V, A, ohm, ...), Measured Value = 11.803890 (C, atm, Hz, ...) 14:27:36 Magnet Test Parameter Measurements P0 = MAIN, Value = 134.97 P1 = MAIN (V), Value = 5.34 P2 = Yoke, Value = 26.20 P3 = Bottom Coil, Value = 28.06 P4 = Top Coil, Value = 28.44 P5 = Water In, Value = 28.73 P6 = Water Out, Value = 30.39 P7 = Ambient, Value = 24.87 P8 = Supply Pres(psi), Value = 123.57 P9 = Return Pres(psi), Value = 11.80 14:27:36 Magnetic Field Measurement Measuring the magnet strength... 14:27:36 Integrated Voltage Measurement... 14:27:37 Magnet Current for MAIN, Imag = 134.9718 A Vtrans = 1.349775 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:27:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005165809 Vs 14:27:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005153604 Vs 14:27:54 Magnet Current for MAIN, Imag = 134.9714 A Vtrans = 1.349771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:28:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005171648 Vs 14:28:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005154378 Vs 14:28:10 Magnet Current for MAIN, Imag = 134.9708 A Vtrans = 1.349765 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:28:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005167996 Vs 14:28:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005160168 Vs 14:28:26 Magnet Current for MAIN, Imag = 134.9709 A Vtrans = 1.349766 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:28:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005170616 Vs 14:28:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005144502 Vs 14:28:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005161090 +- 0.000002600 Vs 14:28:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005161090 +- 0.000002600 Vs BL = -0.05161090 +- 0.00002600 Tm 14:28:45 Position moved: 0.000000 m 14:28:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05161 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05161 0.00003 -0.05161 0.00000 14:28:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05161 0.00003 SL = -0.0516109 +- 0.0000260 Tm^2/m^n 14:28:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0516109 +- 0.0000260 Tm^2/m^n Remeasure 14:28:45 Magnetic Field Measurement Measuring the magnet strength... 14:28:45 Integrated Voltage Measurement... 14:28:46 Magnet Current for MAIN, Imag = 134.9708 A Vtrans = 1.349765 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:28:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005170839 Vs 14:29:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005156655 Vs 14:29:03 Magnet Current for MAIN, Imag = 134.9701 A Vtrans = 1.349759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:29:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005161722 Vs 14:29:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005142705 Vs 14:29:19 Magnet Current for MAIN, Imag = 134.9704 A Vtrans = 1.349761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:29:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005162714 Vs 14:29:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005152627 Vs 14:29:35 Magnet Current for MAIN, Imag = 134.9713 A Vtrans = 1.349770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:29:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005161944 Vs 14:29:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005167571 Vs 14:29:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005159597 +- 0.000005052 Vs 14:29:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005159597 +- 0.000005052 Vs BL = -0.05159597 +- 0.00005052 Tm 14:29:54 Position moved: 0.000000 m 14:29:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05160 0.00005 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05160 0.00005 -0.05160 0.00000 14:29:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05160 0.00005 SL = -0.0515960 +- 0.0000505 Tm^2/m^n 14:29:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0515960 +- 0.0000505 Tm^2/m^n Remeasure 14:29:54 Magnetic Field Measurement Measuring the magnet strength... 14:29:54 Integrated Voltage Measurement... 14:29:55 Magnet Current for MAIN, Imag = 134.9690 A Vtrans = 1.349748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:30:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005177527 Vs 14:30:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005151595 Vs 14:30:12 Magnet Current for MAIN, Imag = 134.9693 A Vtrans = 1.349750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:30:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005162796 Vs 14:30:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005151402 Vs 14:30:28 Magnet Current for MAIN, Imag = 134.9693 A Vtrans = 1.349750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:30:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005171718 Vs 14:30:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005158324 Vs 14:30:43 Magnet Current for MAIN, Imag = 134.9691 A Vtrans = 1.349749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:30:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005167726 Vs 14:30:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005155101 Vs 14:30:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005162024 +- 0.000003164 Vs 14:30:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005162024 +- 0.000003164 Vs BL = -0.05162024 +- 0.00003164 Tm 14:31:02 Position moved: 0.000000 m 14:31:02 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05162 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05162 0.00003 -0.05162 0.00000 14:31:02 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05162 0.00003 SL = -0.0516202 +- 0.0000316 Tm^2/m^n 14:31:02 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0516202 +- 0.0000316 Tm^2/m^n Remeasure 14:31:02 Magnetic Field Measurement Measuring the magnet strength... 14:31:02 Integrated Voltage Measurement... 14:31:03 Magnet Current for MAIN, Imag = 134.9690 A Vtrans = 1.349748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:31:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005172260 Vs 14:31:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005143672 Vs 14:31:20 Magnet Current for MAIN, Imag = 134.9691 A Vtrans = 1.349749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:31:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005165999 Vs 14:31:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005144928 Vs 14:31:36 Magnet Current for MAIN, Imag = 134.9693 A Vtrans = 1.349750 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:31:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005157449 Vs 14:31:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005156139 Vs 14:31:52 Magnet Current for MAIN, Imag = 134.9688 A Vtrans = 1.349745 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:31:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005168604 Vs 14:32:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005155467 Vs 14:32:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005158065 +- 0.000002458 Vs 14:32:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005158065 +- 0.000002458 Vs BL = -0.05158065 +- 0.00002458 Tm 14:32:11 Position moved: 0.000000 m 14:32:11 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05158 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05158 0.00002 -0.05158 0.00000 14:32:11 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05158 0.00002 SL = -0.0515806 +- 0.0000246 Tm^2/m^n 14:32:11 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0515806 +- 0.0000246 Tm^2/m^n Remeasure 14:32:11 Magnetic Field Measurement Measuring the magnet strength... 14:32:11 Integrated Voltage Measurement... 14:32:11 Magnet Current for MAIN, Imag = 134.9685 A Vtrans = 1.349743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:32:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005166094 Vs 14:32:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005146754 Vs 14:32:28 Magnet Current for MAIN, Imag = 134.9684 A Vtrans = 1.349741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:32:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005166955 Vs 14:32:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005159480 Vs 14:32:44 Magnet Current for MAIN, Imag = 134.9686 A Vtrans = 1.349744 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:32:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005178987 Vs 14:32:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005144196 Vs 14:33:00 Magnet Current for MAIN, Imag = 134.9686 A Vtrans = 1.349744 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:33:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005165335 Vs 14:33:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.005151275 Vs 14:33:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.005159885 +- 0.000002669 Vs 14:33:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.005159885 +- 0.000002669 Vs BL = -0.05159885 +- 0.00002669 Tm 14:33:19 Position moved: 0.000000 m 14:33:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.05160 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.05160 0.00003 -0.05160 0.00000 14:33:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.05160 0.00003 SL = -0.0515988 +- 0.0000267 Tm^2/m^n 14:33:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0515988 +- 0.0000267 Tm^2/m^n 14:33:22 Position moved: 0.000000 m 14:33:22 Magnet system MAIN current ramping to 120.0000 A... 14:33:34 Magnet Current for MAIN, Imag = 120.0130 A Vtrans = 1.200187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:33:35 MAIN (V) Voltage Measurement, V = 4.748196 V 14:33:38 Temperature Measurement, Probe Number = 0, T = 26.226000 C 14:33:39 Temperature Measurement, Probe Number = 1, T = 27.826000 C 14:33:39 Temperature Measurement, Probe Number = 2, T = 28.126000 C 14:33:40 Temperature Measurement, Probe Number = 3, T = 28.755000 C 14:33:41 Temperature Measurement, Probe Number = 4, T = 30.072000 C 14:33:41 Temperature Measurement, Probe Number = 5, T = 25.097000 C 14:33:42 Sensor Voltage Measurement, Sensor Number = 0, V = 2.650501 V 14:33:42 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.650501 (V, A, ohm, ...), Measured Value = 123.787575 (C, atm, Hz, ...) 14:33:42 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156378 V 14:33:42 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156378 (V, A, ohm, ...), Measured Value = 11.728313 (C, atm, Hz, ...) 14:33:42 Magnet Test Parameter Measurements P0 = MAIN, Value = 120.01 P1 = MAIN (V), Value = 4.75 P2 = Yoke, Value = 26.23 P3 = Bottom Coil, Value = 27.83 P4 = Top Coil, Value = 28.13 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 30.07 P7 = Ambient, Value = 25.10 P8 = Supply Pres(psi), Value = 123.79 P9 = Return Pres(psi), Value = 11.73 14:33:42 Magnetic Field Measurement Measuring the magnet strength... 14:33:42 Integrated Voltage Measurement... 14:33:43 Magnet Current for MAIN, Imag = 120.0133 A Vtrans = 1.200191 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:33:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004607088 Vs 14:34:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004580188 Vs 14:34:00 Magnet Current for MAIN, Imag = 120.0135 A Vtrans = 1.200192 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:34:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004600837 Vs 14:34:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004581277 Vs 14:34:16 Magnet Current for MAIN, Imag = 120.0131 A Vtrans = 1.200188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:34:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004607051 Vs 14:34:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004590595 Vs 14:34:32 Magnet Current for MAIN, Imag = 120.0131 A Vtrans = 1.200188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:34:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004600523 Vs 14:34:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004573065 Vs 14:34:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004592578 +- 0.000004356 Vs 14:34:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004592578 +- 0.000004356 Vs BL = -0.04592578 +- 0.00004356 Tm 14:34:51 Position moved: 0.000000 m 14:34:51 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04593 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04593 0.00004 -0.04593 0.00000 14:34:51 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04593 0.00004 SL = -0.0459258 +- 0.0000436 Tm^2/m^n 14:34:51 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459258 +- 0.0000436 Tm^2/m^n Remeasure 14:34:51 Magnetic Field Measurement Measuring the magnet strength... 14:34:51 Integrated Voltage Measurement... 14:34:52 Magnet Current for MAIN, Imag = 120.0130 A Vtrans = 1.200187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:35:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004607372 Vs 14:35:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004593028 Vs 14:35:09 Magnet Current for MAIN, Imag = 120.0130 A Vtrans = 1.200187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:35:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004602416 Vs 14:35:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004582241 Vs 14:35:25 Magnet Current for MAIN, Imag = 120.0127 A Vtrans = 1.200184 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:35:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004599914 Vs 14:35:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004589630 Vs 14:35:41 Magnet Current for MAIN, Imag = 120.0128 A Vtrans = 1.200186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:35:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004599522 Vs 14:35:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004583751 Vs 14:35:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004594734 +- 0.000003364 Vs 14:35:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004594734 +- 0.000003364 Vs BL = -0.04594734 +- 0.00003364 Tm 14:36:00 Position moved: 0.000000 m 14:36:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04595 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04595 0.00003 -0.04595 0.00000 14:36:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04595 0.00003 SL = -0.0459473 +- 0.0000336 Tm^2/m^n 14:36:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459473 +- 0.0000336 Tm^2/m^n Remeasure 14:36:00 Magnetic Field Measurement Measuring the magnet strength... 14:36:00 Integrated Voltage Measurement... 14:36:00 Magnet Current for MAIN, Imag = 120.0126 A Vtrans = 1.200183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:36:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004596869 Vs 14:36:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004583663 Vs 14:36:17 Magnet Current for MAIN, Imag = 120.0130 A Vtrans = 1.200187 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:36:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004606692 Vs 14:36:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004587489 Vs 14:36:33 Magnet Current for MAIN, Imag = 120.0128 A Vtrans = 1.200186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:36:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004602760 Vs 14:36:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004592716 Vs 14:36:49 Magnet Current for MAIN, Imag = 120.0127 A Vtrans = 1.200184 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:36:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004600411 Vs 14:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004587858 Vs 14:37:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004594807 +- 0.000002953 Vs 14:37:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004594807 +- 0.000002953 Vs BL = -0.04594807 +- 0.00002953 Tm 14:37:09 Position moved: 0.000000 m 14:37:09 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04595 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04595 0.00003 -0.04595 0.00000 14:37:09 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04595 0.00003 SL = -0.0459481 +- 0.0000295 Tm^2/m^n 14:37:09 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459481 +- 0.0000295 Tm^2/m^n Remeasure 14:37:09 Magnetic Field Measurement Measuring the magnet strength... 14:37:09 Integrated Voltage Measurement... 14:37:09 Magnet Current for MAIN, Imag = 120.0126 A Vtrans = 1.200183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:37:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004601440 Vs 14:37:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004584554 Vs 14:37:26 Magnet Current for MAIN, Imag = 120.0128 A Vtrans = 1.200186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:37:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004594327 Vs 14:37:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004584980 Vs 14:37:42 Magnet Current for MAIN, Imag = 120.0131 A Vtrans = 1.200188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:37:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004610739 Vs 14:37:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004586353 Vs 14:37:58 Magnet Current for MAIN, Imag = 120.0131 A Vtrans = 1.200188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:38:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004597683 Vs 14:38:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004591409 Vs 14:38:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004593936 +- 0.000003195 Vs 14:38:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004593936 +- 0.000003195 Vs BL = -0.04593936 +- 0.00003195 Tm 14:38:17 Position moved: 0.000000 m 14:38:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04594 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04594 0.00003 -0.04594 0.00000 14:38:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04594 0.00003 SL = -0.0459394 +- 0.0000320 Tm^2/m^n 14:38:17 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459394 +- 0.0000320 Tm^2/m^n Remeasure 14:38:17 Magnetic Field Measurement Measuring the magnet strength... 14:38:17 Integrated Voltage Measurement... 14:38:18 Magnet Current for MAIN, Imag = 120.0132 A Vtrans = 1.200190 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:38:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004601021 Vs 14:38:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004583809 Vs 14:38:35 Magnet Current for MAIN, Imag = 120.0128 A Vtrans = 1.200186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:38:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004599691 Vs 14:38:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004573821 Vs 14:38:50 Magnet Current for MAIN, Imag = 120.0128 A Vtrans = 1.200186 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:38:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004603791 Vs 14:39:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004582586 Vs 14:39:06 Magnet Current for MAIN, Imag = 120.0125 A Vtrans = 1.200182 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:39:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004595569 Vs 14:39:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004588492 Vs 14:39:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004591098 +- 0.000002541 Vs 14:39:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004591098 +- 0.000002541 Vs BL = -0.04591098 +- 0.00002541 Tm 14:39:26 Position moved: 0.000000 m 14:39:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04591 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04591 0.00003 -0.04591 0.00000 14:39:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04591 0.00003 SL = -0.0459110 +- 0.0000254 Tm^2/m^n 14:39:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0459110 +- 0.0000254 Tm^2/m^n 14:39:28 Position moved: 0.000000 m 14:39:28 Magnet system MAIN current ramping to 105.0000 A... 14:39:40 Magnet Current for MAIN, Imag = 104.9938 A Vtrans = 1.049995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:39:41 MAIN (V) Voltage Measurement, V = 4.152610 V 14:39:45 Temperature Measurement, Probe Number = 0, T = 26.243000 C 14:39:45 Temperature Measurement, Probe Number = 1, T = 27.742000 C 14:39:46 Temperature Measurement, Probe Number = 2, T = 28.160000 C 14:39:46 Temperature Measurement, Probe Number = 3, T = 28.749000 C 14:39:47 Temperature Measurement, Probe Number = 4, T = 29.810000 C 14:39:47 Temperature Measurement, Probe Number = 5, T = 25.144000 C 14:39:48 Sensor Voltage Measurement, Sensor Number = 0, V = 2.656628 V 14:39:48 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.656628 (V, A, ohm, ...), Measured Value = 124.247115 (C, atm, Hz, ...) 14:39:49 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157893 V 14:39:49 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157893 (V, A, ohm, ...), Measured Value = 11.842005 (C, atm, Hz, ...) 14:39:49 Magnet Test Parameter Measurements P0 = MAIN, Value = 104.99 P1 = MAIN (V), Value = 4.15 P2 = Yoke, Value = 26.24 P3 = Bottom Coil, Value = 27.74 P4 = Top Coil, Value = 28.16 P5 = Water In, Value = 28.75 P6 = Water Out, Value = 29.81 P7 = Ambient, Value = 25.14 P8 = Supply Pres(psi), Value = 124.25 P9 = Return Pres(psi), Value = 11.84 14:39:49 Magnetic Field Measurement Measuring the magnet strength... 14:39:49 Integrated Voltage Measurement... 14:39:49 Magnet Current for MAIN, Imag = 104.9939 A Vtrans = 1.049996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:39:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004030538 Vs 14:40:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004010018 Vs 14:40:06 Magnet Current for MAIN, Imag = 104.9940 A Vtrans = 1.049997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:40:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004031900 Vs 14:40:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004014718 Vs 14:40:22 Magnet Current for MAIN, Imag = 104.9936 A Vtrans = 1.049994 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:40:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004025442 Vs 14:40:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004017733 Vs 14:40:38 Magnet Current for MAIN, Imag = 104.9938 A Vtrans = 1.049995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:40:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004029408 Vs 14:40:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004015447 Vs 14:40:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004021901 +- 0.000001117 Vs 14:40:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004021901 +- 0.000001117 Vs BL = -0.04021901 +- 0.00001117 Tm 14:40:57 Position moved: 0.000000 m 14:40:57 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04022 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04022 0.00001 -0.04022 0.00000 14:40:57 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04022 0.00001 SL = -0.0402190 +- 0.0000112 Tm^2/m^n 14:40:57 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0402190 +- 0.0000112 Tm^2/m^n Remeasure 14:40:57 Magnetic Field Measurement Measuring the magnet strength... 14:40:57 Integrated Voltage Measurement... 14:40:58 Magnet Current for MAIN, Imag = 104.9939 A Vtrans = 1.049996 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004029060 Vs 14:41:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004013996 Vs 14:41:15 Magnet Current for MAIN, Imag = 104.9941 A Vtrans = 1.049999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:41:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004038862 Vs 14:41:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004016120 Vs 14:41:31 Magnet Current for MAIN, Imag = 104.9944 A Vtrans = 1.050001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:41:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004021507 Vs 14:41:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004017744 Vs 14:41:47 Magnet Current for MAIN, Imag = 104.9945 A Vtrans = 1.050002 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:41:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004024598 Vs 14:42:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004017219 Vs 14:42:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004022388 +- 0.000003025 Vs 14:42:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004022388 +- 0.000003025 Vs BL = -0.04022388 +- 0.00003025 Tm 14:42:06 Position moved: 0.000000 m 14:42:06 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04022 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04022 0.00003 -0.04022 0.00000 14:42:06 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04022 0.00003 SL = -0.0402239 +- 0.0000302 Tm^2/m^n 14:42:06 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0402239 +- 0.0000302 Tm^2/m^n Remeasure 14:42:06 Magnetic Field Measurement Measuring the magnet strength... 14:42:06 Integrated Voltage Measurement... 14:42:07 Magnet Current for MAIN, Imag = 104.9946 A Vtrans = 1.050004 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:42:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004027460 Vs 14:42:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004018589 Vs 14:42:24 Magnet Current for MAIN, Imag = 104.9941 A Vtrans = 1.049999 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:42:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004028971 Vs 14:42:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004019238 Vs 14:42:40 Magnet Current for MAIN, Imag = 104.9944 A Vtrans = 1.050001 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:42:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004024282 Vs 14:42:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004019892 Vs 14:42:56 Magnet Current for MAIN, Imag = 104.9943 A Vtrans = 1.050000 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:43:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004021137 Vs 14:43:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.004017570 Vs 14:43:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.004022142 +- 0.000001761 Vs 14:43:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.004022142 +- 0.000001761 Vs BL = -0.04022142 +- 0.00001761 Tm 14:43:15 Position moved: 0.000000 m 14:43:15 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.04022 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.04022 0.00002 -0.04022 0.00000 14:43:15 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.04022 0.00002 SL = -0.0402214 +- 0.0000176 Tm^2/m^n 14:43:15 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0402214 +- 0.0000176 Tm^2/m^n 14:43:18 Position moved: 0.000000 m 14:43:18 Magnet system MAIN current ramping to 90.0000 A... 14:43:30 Magnet Current for MAIN, Imag = 89.9658 A Vtrans = 0.899716 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:43:31 MAIN (V) Voltage Measurement, V = 3.556525 V 14:43:34 Temperature Measurement, Probe Number = 0, T = 26.197000 C 14:43:35 Temperature Measurement, Probe Number = 1, T = 27.696000 C 14:43:35 Temperature Measurement, Probe Number = 2, T = 28.232000 C 14:43:36 Temperature Measurement, Probe Number = 3, T = 28.721000 C 14:43:37 Temperature Measurement, Probe Number = 4, T = 29.569000 C 14:43:37 Temperature Measurement, Probe Number = 5, T = 24.980000 C 14:43:38 Sensor Voltage Measurement, Sensor Number = 0, V = 2.645553 V 14:43:38 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.645553 (V, A, ohm, ...), Measured Value = 123.416445 (C, atm, Hz, ...) 14:43:38 Sensor Voltage Measurement, Sensor Number = 1, V = 1.154722 V 14:43:38 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.154722 (V, A, ohm, ...), Measured Value = 11.604135 (C, atm, Hz, ...) 14:43:38 Magnet Test Parameter Measurements P0 = MAIN, Value = 89.97 P1 = MAIN (V), Value = 3.56 P2 = Yoke, Value = 26.20 P3 = Bottom Coil, Value = 27.70 P4 = Top Coil, Value = 28.23 P5 = Water In, Value = 28.72 P6 = Water Out, Value = 29.57 P7 = Ambient, Value = 24.98 P8 = Supply Pres(psi), Value = 123.42 P9 = Return Pres(psi), Value = 11.60 14:43:38 Magnetic Field Measurement Measuring the magnet strength... 14:43:38 Integrated Voltage Measurement... 14:43:39 Magnet Current for MAIN, Imag = 89.9662 A Vtrans = 0.899719 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:43:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003460357 Vs 14:43:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003443103 Vs 14:43:56 Magnet Current for MAIN, Imag = 89.9664 A Vtrans = 0.899721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:44:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003455479 Vs 14:44:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003446236 Vs 14:44:12 Magnet Current for MAIN, Imag = 89.9668 A Vtrans = 0.899726 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:44:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003457525 Vs 14:44:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003445662 Vs 14:44:28 Magnet Current for MAIN, Imag = 89.9661 A Vtrans = 0.899719 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:44:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003457245 Vs 14:44:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.003442312 Vs 14:44:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.003450990 +- 0.000000774 Vs 14:44:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.003450990 +- 0.000000774 Vs BL = -0.03450990 +- 0.00000774 Tm 14:44:47 Position moved: 0.000000 m 14:44:47 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.03451 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.03451 0.00001 -0.03451 0.00000 14:44:47 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.03451 0.00001 SL = -0.0345099 +- 0.0000077 Tm^2/m^n 14:44:47 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0345099 +- 0.0000077 Tm^2/m^n 14:44:50 Position moved: 0.000000 m 14:44:50 Magnet system MAIN current ramping to 75.0000 A... 14:45:02 Magnet Current for MAIN, Imag = 75.0111 A Vtrans = 0.750169 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:45:03 MAIN (V) Voltage Measurement, V = 2.964188 V 14:45:06 Temperature Measurement, Probe Number = 0, T = 26.249000 C 14:45:07 Temperature Measurement, Probe Number = 1, T = 27.600000 C 14:45:08 Temperature Measurement, Probe Number = 2, T = 28.099000 C 14:45:08 Temperature Measurement, Probe Number = 3, T = 28.792000 C 14:45:09 Temperature Measurement, Probe Number = 4, T = 29.443000 C 14:45:09 Temperature Measurement, Probe Number = 5, T = 25.134000 C 14:45:10 Sensor Voltage Measurement, Sensor Number = 0, V = 2.669993 V 14:45:10 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.669993 (V, A, ohm, ...), Measured Value = 125.249452 (C, atm, Hz, ...) 14:45:11 Sensor Voltage Measurement, Sensor Number = 1, V = 1.157099 V 14:45:11 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.157099 (V, A, ohm, ...), Measured Value = 11.782440 (C, atm, Hz, ...) 14:45:11 Magnet Test Parameter Measurements P0 = MAIN, Value = 75.01 P1 = MAIN (V), Value = 2.96 P2 = Yoke, Value = 26.25 P3 = Bottom Coil, Value = 27.60 P4 = Top Coil, Value = 28.10 P5 = Water In, Value = 28.79 P6 = Water Out, Value = 29.44 P7 = Ambient, Value = 25.13 P8 = Supply Pres(psi), Value = 125.25 P9 = Return Pres(psi), Value = 11.78 14:45:11 Magnetic Field Measurement Measuring the magnet strength... 14:45:11 Integrated Voltage Measurement... 14:45:11 Magnet Current for MAIN, Imag = 75.0111 A Vtrans = 0.750168 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:45:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002885972 Vs 14:45:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002874379 Vs 14:45:29 Magnet Current for MAIN, Imag = 75.0110 A Vtrans = 0.750167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:45:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002887927 Vs 14:45:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002876811 Vs 14:45:44 Magnet Current for MAIN, Imag = 75.0109 A Vtrans = 0.750166 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:45:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002888523 Vs 14:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002870589 Vs 14:46:00 Magnet Current for MAIN, Imag = 75.0111 A Vtrans = 0.750168 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:46:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002884072 Vs 14:46:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002869720 Vs 14:46:15 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002879749 +- 0.000001951 Vs 14:46:15 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002879749 +- 0.000001951 Vs BL = -0.02879749 +- 0.00001951 Tm 14:46:19 Position moved: 0.000000 m 14:46:19 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02880 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02880 0.00002 -0.02880 0.00000 14:46:19 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02880 0.00002 SL = -0.0287975 +- 0.0000195 Tm^2/m^n 14:46:19 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287975 +- 0.0000195 Tm^2/m^n Remeasure 14:46:19 Magnetic Field Measurement Measuring the magnet strength... 14:46:19 Integrated Voltage Measurement... 14:46:20 Magnet Current for MAIN, Imag = 75.0110 A Vtrans = 0.750167 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:46:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002881458 Vs 14:46:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002876321 Vs 14:46:37 Magnet Current for MAIN, Imag = 75.0111 A Vtrans = 0.750169 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:46:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002889613 Vs 14:46:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002872141 Vs 14:46:53 Magnet Current for MAIN, Imag = 75.0115 A Vtrans = 0.750173 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:47:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002886353 Vs 14:47:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002876726 Vs 14:47:09 Magnet Current for MAIN, Imag = 75.0119 A Vtrans = 0.750177 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:47:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002885257 Vs 14:47:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002858992 Vs 14:47:24 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002878358 +- 0.000003729 Vs 14:47:24 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002878358 +- 0.000003729 Vs BL = -0.02878358 +- 0.00003729 Tm 14:47:28 Position moved: 0.000000 m 14:47:28 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02878 0.00004 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02878 0.00004 -0.02878 0.00000 14:47:28 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02878 0.00004 SL = -0.0287836 +- 0.0000373 Tm^2/m^n 14:47:28 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287836 +- 0.0000373 Tm^2/m^n Remeasure 14:47:28 Magnetic Field Measurement Measuring the magnet strength... 14:47:28 Integrated Voltage Measurement... 14:47:28 Magnet Current for MAIN, Imag = 75.0126 A Vtrans = 0.750183 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:47:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002880421 Vs 14:47:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002866385 Vs 14:47:45 Magnet Current for MAIN, Imag = 75.0130 A Vtrans = 0.750188 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:47:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002891171 Vs 14:48:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002869193 Vs 14:48:01 Magnet Current for MAIN, Imag = 75.0135 A Vtrans = 0.750193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:48:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002886975 Vs 14:48:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002871717 Vs 14:48:17 Magnet Current for MAIN, Imag = 75.0143 A Vtrans = 0.750201 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:48:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002891569 Vs 14:48:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002868663 Vs 14:48:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002878262 +- 0.000002824 Vs 14:48:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002878262 +- 0.000002824 Vs BL = -0.02878262 +- 0.00002824 Tm 14:48:36 Position moved: 0.000000 m 14:48:36 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02878 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02878 0.00003 -0.02878 0.00000 14:48:36 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02878 0.00003 SL = -0.0287826 +- 0.0000282 Tm^2/m^n 14:48:36 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0287826 +- 0.0000282 Tm^2/m^n Remeasure 14:48:36 Magnetic Field Measurement Measuring the magnet strength... 14:48:36 Integrated Voltage Measurement... 14:48:37 Magnet Current for MAIN, Imag = 75.0147 A Vtrans = 0.750204 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:48:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002887728 Vs 14:48:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002872389 Vs 14:48:54 Magnet Current for MAIN, Imag = 75.0150 A Vtrans = 0.750207 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:49:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002887584 Vs 14:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002872540 Vs 14:49:10 Magnet Current for MAIN, Imag = 75.0142 A Vtrans = 0.750199 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:49:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002891535 Vs 14:49:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002881220 Vs 14:49:26 Magnet Current for MAIN, Imag = 75.0139 A Vtrans = 0.750196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:49:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002885479 Vs 14:49:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002874950 Vs 14:49:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002881678 +- 0.000002714 Vs 14:49:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002881678 +- 0.000002714 Vs BL = -0.02881678 +- 0.00002714 Tm 14:49:45 Position moved: 0.000000 m 14:49:45 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02882 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02882 0.00003 -0.02882 0.00000 14:49:45 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02882 0.00003 SL = -0.0288168 +- 0.0000271 Tm^2/m^n 14:49:45 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0288168 +- 0.0000271 Tm^2/m^n Remeasure 14:49:45 Magnetic Field Measurement Measuring the magnet strength... 14:49:45 Integrated Voltage Measurement... 14:49:46 Magnet Current for MAIN, Imag = 75.0143 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:49:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002884819 Vs 14:50:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002880251 Vs 14:50:03 Magnet Current for MAIN, Imag = 75.0143 A Vtrans = 0.750200 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:50:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002893420 Vs 14:50:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002873654 Vs 14:50:19 Magnet Current for MAIN, Imag = 75.0148 A Vtrans = 0.750205 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:50:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002886154 Vs 14:50:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002882793 Vs 14:50:35 Magnet Current for MAIN, Imag = 75.0156 A Vtrans = 0.750213 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:50:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002885507 Vs 14:50:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002876788 Vs 14:50:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002882923 +- 0.000001233 Vs 14:50:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002882923 +- 0.000001233 Vs BL = -0.02882923 +- 0.00001233 Tm 14:50:54 Position moved: 0.000000 m 14:50:54 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02883 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02883 0.00001 -0.02883 0.00000 14:50:54 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02883 0.00001 SL = -0.0288292 +- 0.0000123 Tm^2/m^n 14:50:54 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0288292 +- 0.0000123 Tm^2/m^n 14:50:57 Position moved: 0.000000 m 14:50:57 Magnet system MAIN current ramping to 60.0000 A... 14:51:09 Magnet Current for MAIN, Imag = 59.9854 A Vtrans = 0.599911 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:51:10 MAIN (V) Voltage Measurement, V = 2.369794 V 14:51:13 Temperature Measurement, Probe Number = 0, T = 26.293000 C 14:51:14 Temperature Measurement, Probe Number = 1, T = 27.530000 C 14:51:14 Temperature Measurement, Probe Number = 2, T = 27.984000 C 14:51:15 Temperature Measurement, Probe Number = 3, T = 28.913000 C 14:51:16 Temperature Measurement, Probe Number = 4, T = 29.303000 C 14:51:16 Temperature Measurement, Probe Number = 5, T = 25.305000 C 14:51:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.657163 V 14:51:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.657163 (V, A, ohm, ...), Measured Value = 124.287203 (C, atm, Hz, ...) 14:51:17 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156349 V 14:51:17 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156349 (V, A, ohm, ...), Measured Value = 11.726160 (C, atm, Hz, ...) 14:51:17 Magnet Test Parameter Measurements P0 = MAIN, Value = 59.99 P1 = MAIN (V), Value = 2.37 P2 = Yoke, Value = 26.29 P3 = Bottom Coil, Value = 27.53 P4 = Top Coil, Value = 27.98 P5 = Water In, Value = 28.91 P6 = Water Out, Value = 29.30 P7 = Ambient, Value = 25.30 P8 = Supply Pres(psi), Value = 124.29 P9 = Return Pres(psi), Value = 11.73 14:51:17 Magnetic Field Measurement Measuring the magnet strength... 14:51:17 Integrated Voltage Measurement... 14:51:18 Magnet Current for MAIN, Imag = 59.9859 A Vtrans = 0.599916 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:51:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002318512 Vs 14:51:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002297711 Vs 14:51:35 Magnet Current for MAIN, Imag = 59.9855 A Vtrans = 0.599913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:51:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002313083 Vs 14:51:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002297467 Vs 14:51:51 Magnet Current for MAIN, Imag = 59.9858 A Vtrans = 0.599915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002317491 Vs 14:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002297042 Vs 14:52:07 Magnet Current for MAIN, Imag = 59.9858 A Vtrans = 0.599915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:52:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002314712 Vs 14:52:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002302453 Vs 14:52:23 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002307309 +- 0.000001265 Vs 14:52:23 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002307309 +- 0.000001265 Vs BL = -0.02307309 +- 0.00001265 Tm 14:52:26 Position moved: 0.000000 m 14:52:26 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02307 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02307 0.00001 -0.02307 0.00000 14:52:26 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02307 0.00001 SL = -0.0230731 +- 0.0000127 Tm^2/m^n 14:52:26 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0230731 +- 0.0000127 Tm^2/m^n Remeasure 14:52:26 Magnetic Field Measurement Measuring the magnet strength... 14:52:26 Integrated Voltage Measurement... 14:52:27 Magnet Current for MAIN, Imag = 59.9861 A Vtrans = 0.599918 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:52:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002316594 Vs 14:52:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002304840 Vs 14:52:44 Magnet Current for MAIN, Imag = 59.9858 A Vtrans = 0.599915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:52:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002313650 Vs 14:52:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002301772 Vs 14:53:00 Magnet Current for MAIN, Imag = 59.9863 A Vtrans = 0.599920 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:53:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002312667 Vs 14:53:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002298352 Vs 14:53:16 Magnet Current for MAIN, Imag = 59.9867 A Vtrans = 0.599924 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:53:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002313575 Vs 14:53:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002304692 Vs 14:53:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002308268 +- 0.000001915 Vs 14:53:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002308268 +- 0.000001915 Vs BL = -0.02308268 +- 0.00001915 Tm 14:53:34 Position moved: 0.000000 m 14:53:34 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02308 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02308 0.00002 -0.02308 0.00000 14:53:34 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02308 0.00002 SL = -0.0230827 +- 0.0000191 Tm^2/m^n 14:53:34 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0230827 +- 0.0000191 Tm^2/m^n Remeasure 14:53:34 Magnetic Field Measurement Measuring the magnet strength... 14:53:34 Integrated Voltage Measurement... 14:53:35 Magnet Current for MAIN, Imag = 59.9878 A Vtrans = 0.599935 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:53:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002313355 Vs 14:53:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002303337 Vs 14:53:52 Magnet Current for MAIN, Imag = 59.9892 A Vtrans = 0.599949 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:54:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002308364 Vs 14:54:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002294175 Vs 14:54:08 Magnet Current for MAIN, Imag = 59.9889 A Vtrans = 0.599947 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:54:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002309143 Vs 14:54:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002303034 Vs 14:54:24 Magnet Current for MAIN, Imag = 59.9903 A Vtrans = 0.599960 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:54:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002307670 Vs 14:54:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002301710 Vs 14:54:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002305098 +- 0.000002567 Vs 14:54:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002305098 +- 0.000002567 Vs BL = -0.02305098 +- 0.00002567 Tm 14:54:43 Position moved: 0.000000 m 14:54:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02305 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02305 0.00003 -0.02305 0.00000 14:54:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02305 0.00003 SL = -0.0230510 +- 0.0000257 Tm^2/m^n 14:54:43 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0230510 +- 0.0000257 Tm^2/m^n Remeasure 14:54:43 Magnetic Field Measurement Measuring the magnet strength... 14:54:43 Integrated Voltage Measurement... 14:54:44 Magnet Current for MAIN, Imag = 59.9906 A Vtrans = 0.599964 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:54:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002315305 Vs 14:55:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002295699 Vs 14:55:01 Magnet Current for MAIN, Imag = 59.9912 A Vtrans = 0.599970 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:55:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002310874 Vs 14:55:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002295776 Vs 14:55:16 Magnet Current for MAIN, Imag = 59.9918 A Vtrans = 0.599976 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:55:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002305502 Vs 14:55:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002302794 Vs 14:55:32 Magnet Current for MAIN, Imag = 59.9921 A Vtrans = 0.599978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:55:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002311190 Vs 14:55:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002300592 Vs 14:55:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002304716 +- 0.000001032 Vs 14:55:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002304716 +- 0.000001032 Vs BL = -0.02304716 +- 0.00001032 Tm 14:55:52 Position moved: 0.000000 m 14:55:52 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02305 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02305 0.00001 -0.02305 0.00000 14:55:52 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02305 0.00001 SL = -0.0230472 +- 0.0000103 Tm^2/m^n 14:55:52 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0230472 +- 0.0000103 Tm^2/m^n Remeasure 14:55:52 Magnetic Field Measurement Measuring the magnet strength... 14:55:52 Integrated Voltage Measurement... 14:55:52 Magnet Current for MAIN, Imag = 59.9924 A Vtrans = 0.599981 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:56:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002315088 Vs 14:56:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002306492 Vs 14:56:09 Magnet Current for MAIN, Imag = 59.9921 A Vtrans = 0.599978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:56:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002311271 Vs 14:56:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002304847 Vs 14:56:25 Magnet Current for MAIN, Imag = 59.9921 A Vtrans = 0.599978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:56:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002313471 Vs 14:56:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002305905 Vs 14:56:41 Magnet Current for MAIN, Imag = 59.9919 A Vtrans = 0.599977 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:56:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002308171 Vs 14:56:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.002298944 Vs 14:56:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.002308024 +- 0.000002755 Vs 14:56:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.002308024 +- 0.000002755 Vs BL = -0.02308024 +- 0.00002755 Tm 14:57:00 Position moved: 0.000000 m 14:57:00 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.02308 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.02308 0.00003 -0.02308 0.00000 14:57:00 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.02308 0.00003 SL = -0.0230802 +- 0.0000276 Tm^2/m^n 14:57:00 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0230802 +- 0.0000276 Tm^2/m^n 14:57:03 Position moved: 0.000000 m 14:57:03 Magnet system MAIN current ramping to 45.0000 A... 14:57:15 Magnet Current for MAIN, Imag = 44.9686 A Vtrans = 0.449743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:57:16 MAIN (V) Voltage Measurement, V = 1.775904 V 14:57:19 Temperature Measurement, Probe Number = 0, T = 26.353000 C 14:57:20 Temperature Measurement, Probe Number = 1, T = 27.527000 C 14:57:20 Temperature Measurement, Probe Number = 2, T = 28.037000 C 14:57:21 Temperature Measurement, Probe Number = 3, T = 28.934000 C 14:57:22 Temperature Measurement, Probe Number = 4, T = 29.163000 C 14:57:22 Temperature Measurement, Probe Number = 5, T = 25.450000 C 14:57:23 Sensor Voltage Measurement, Sensor Number = 0, V = 2.652619 V 14:57:23 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.652619 (V, A, ohm, ...), Measured Value = 123.946410 (C, atm, Hz, ...) 14:57:23 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156670 V 14:57:23 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156670 (V, A, ohm, ...), Measured Value = 11.750227 (C, atm, Hz, ...) 14:57:23 Magnet Test Parameter Measurements P0 = MAIN, Value = 44.97 P1 = MAIN (V), Value = 1.78 P2 = Yoke, Value = 26.35 P3 = Bottom Coil, Value = 27.53 P4 = Top Coil, Value = 28.04 P5 = Water In, Value = 28.93 P6 = Water Out, Value = 29.16 P7 = Ambient, Value = 25.45 P8 = Supply Pres(psi), Value = 123.95 P9 = Return Pres(psi), Value = 11.75 14:57:23 Magnetic Field Measurement Measuring the magnet strength... 14:57:23 Integrated Voltage Measurement... 14:57:24 Magnet Current for MAIN, Imag = 44.9678 A Vtrans = 0.449735 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:57:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001740093 Vs 14:57:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001726993 Vs 14:57:41 Magnet Current for MAIN, Imag = 44.9674 A Vtrans = 0.449731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:57:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001737751 Vs 14:57:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001733639 Vs 14:57:57 Magnet Current for MAIN, Imag = 44.9679 A Vtrans = 0.449736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:58:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001742193 Vs 14:58:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001725193 Vs 14:58:13 Magnet Current for MAIN, Imag = 44.9696 A Vtrans = 0.449753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:58:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001738341 Vs 14:58:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001734137 Vs 14:58:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001734792 +- 0.000001192 Vs 14:58:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001734792 +- 0.000001192 Vs BL = -0.01734792 +- 0.00001192 Tm 14:58:32 Position moved: 0.000000 m 14:58:32 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01735 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01735 0.00001 -0.01735 0.00000 14:58:32 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01735 0.00001 SL = -0.0173479 +- 0.0000119 Tm^2/m^n 14:58:32 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0173479 +- 0.0000119 Tm^2/m^n Remeasure 14:58:32 Magnetic Field Measurement Measuring the magnet strength... 14:58:32 Integrated Voltage Measurement... 14:58:33 Magnet Current for MAIN, Imag = 44.9716 A Vtrans = 0.449774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:58:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001732137 Vs 14:58:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001730060 Vs 14:58:50 Magnet Current for MAIN, Imag = 44.9710 A Vtrans = 0.449767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:58:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001741860 Vs 14:59:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001733003 Vs 14:59:06 Magnet Current for MAIN, Imag = 44.9713 A Vtrans = 0.449770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:59:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001742041 Vs 14:59:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001728471 Vs 14:59:22 Magnet Current for MAIN, Imag = 44.9705 A Vtrans = 0.449763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:59:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001742167 Vs 14:59:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001731647 Vs 14:59:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001735173 +- 0.000002486 Vs 14:59:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001735173 +- 0.000002486 Vs BL = -0.01735173 +- 0.00002486 Tm 14:59:41 Position moved: 0.000000 m 14:59:41 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01735 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01735 0.00002 -0.01735 0.00000 14:59:41 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01735 0.00002 SL = -0.0173517 +- 0.0000249 Tm^2/m^n 14:59:41 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0173517 +- 0.0000249 Tm^2/m^n Remeasure 14:59:41 Magnetic Field Measurement Measuring the magnet strength... 14:59:41 Integrated Voltage Measurement... 14:59:42 Magnet Current for MAIN, Imag = 44.9700 A Vtrans = 0.449757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 14:59:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001741372 Vs 14:59:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001727582 Vs 14:59:59 Magnet Current for MAIN, Imag = 44.9710 A Vtrans = 0.449767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:00:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001743216 Vs 15:00:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001729537 Vs 15:00:15 Magnet Current for MAIN, Imag = 44.9713 A Vtrans = 0.449770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:00:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001739325 Vs 15:00:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001728767 Vs 15:00:31 Magnet Current for MAIN, Imag = 44.9705 A Vtrans = 0.449763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:00:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001734935 Vs 15:00:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001727944 Vs 15:00:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001734085 +- 0.000001761 Vs 15:00:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001734085 +- 0.000001761 Vs BL = -0.01734085 +- 0.00001761 Tm 15:00:50 Position moved: 0.000000 m 15:00:50 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01734 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01734 0.00002 -0.01734 0.00000 15:00:50 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01734 0.00002 SL = -0.0173408 +- 0.0000176 Tm^2/m^n 15:00:50 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0173408 +- 0.0000176 Tm^2/m^n Remeasure 15:00:50 Magnetic Field Measurement Measuring the magnet strength... 15:00:50 Integrated Voltage Measurement... 15:00:51 Magnet Current for MAIN, Imag = 44.9712 A Vtrans = 0.449770 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:00:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001739425 Vs 15:01:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001730115 Vs 15:01:08 Magnet Current for MAIN, Imag = 44.9714 A Vtrans = 0.449771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:01:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001739593 Vs 15:01:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001728639 Vs 15:01:24 Magnet Current for MAIN, Imag = 44.9707 A Vtrans = 0.449764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:01:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001742504 Vs 15:01:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001725169 Vs 15:01:40 Magnet Current for MAIN, Imag = 44.9714 A Vtrans = 0.449771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:01:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001741024 Vs 15:01:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001729850 Vs 15:01:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001734540 +- 0.000000619 Vs 15:01:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001734540 +- 0.000000619 Vs BL = -0.01734540 +- 0.00000619 Tm 15:01:59 Position moved: 0.000000 m 15:01:59 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01735 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01735 0.00001 -0.01735 0.00000 15:01:59 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01735 0.00001 SL = -0.0173454 +- 0.0000062 Tm^2/m^n 15:01:59 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0173454 +- 0.0000062 Tm^2/m^n Remeasure 15:01:59 Magnetic Field Measurement Measuring the magnet strength... 15:01:59 Integrated Voltage Measurement... 15:02:00 Magnet Current for MAIN, Imag = 44.9720 A Vtrans = 0.449777 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:02:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001736969 Vs 15:02:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001722375 Vs 15:02:17 Magnet Current for MAIN, Imag = 44.9722 A Vtrans = 0.449779 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:02:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001741988 Vs 15:02:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001725860 Vs 15:02:32 Magnet Current for MAIN, Imag = 44.9719 A Vtrans = 0.449777 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:02:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001737880 Vs 15:02:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001724757 Vs 15:02:48 Magnet Current for MAIN, Imag = 44.9717 A Vtrans = 0.449774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:02:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001737725 Vs 15:03:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001726490 Vs 15:03:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001731755 +- 0.000001529 Vs 15:03:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001731755 +- 0.000001529 Vs BL = -0.01731755 +- 0.00001529 Tm 15:03:07 Position moved: 0.000000 m 15:03:07 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01732 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01732 0.00002 -0.01732 0.00000 15:03:07 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01732 0.00002 SL = -0.0173176 +- 0.0000153 Tm^2/m^n 15:03:07 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0173176 +- 0.0000153 Tm^2/m^n 15:03:10 Position moved: 0.000000 m 15:03:10 Magnet system MAIN current ramping to 30.0000 A... 15:03:22 Magnet Current for MAIN, Imag = 30.0200 A Vtrans = 0.300257 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:03:23 MAIN (V) Voltage Measurement, V = 1.185284 V 15:03:26 Temperature Measurement, Probe Number = 0, T = 26.378000 C 15:03:27 Temperature Measurement, Probe Number = 1, T = 27.490000 C 15:03:28 Temperature Measurement, Probe Number = 2, T = 28.052000 C 15:03:28 Temperature Measurement, Probe Number = 3, T = 28.938000 C 15:03:29 Temperature Measurement, Probe Number = 4, T = 29.101000 C 15:03:29 Temperature Measurement, Probe Number = 5, T = 25.559000 C 15:03:30 Sensor Voltage Measurement, Sensor Number = 0, V = 2.635005 V 15:03:30 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.635005 (V, A, ohm, ...), Measured Value = 122.625382 (C, atm, Hz, ...) 15:03:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156516 V 15:03:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156516 (V, A, ohm, ...), Measured Value = 11.738707 (C, atm, Hz, ...) 15:03:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 30.02 P1 = MAIN (V), Value = 1.19 P2 = Yoke, Value = 26.38 P3 = Bottom Coil, Value = 27.49 P4 = Top Coil, Value = 28.05 P5 = Water In, Value = 28.94 P6 = Water Out, Value = 29.10 P7 = Ambient, Value = 25.56 P8 = Supply Pres(psi), Value = 122.63 P9 = Return Pres(psi), Value = 11.74 15:03:31 Magnetic Field Measurement Measuring the magnet strength... 15:03:31 Integrated Voltage Measurement... 15:03:31 Magnet Current for MAIN, Imag = 30.0197 A Vtrans = 0.300254 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:03:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001166059 Vs 15:03:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001160917 Vs 15:03:48 Magnet Current for MAIN, Imag = 30.0193 A Vtrans = 0.300250 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:03:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001169370 Vs 15:04:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001157512 Vs 15:04:04 Magnet Current for MAIN, Imag = 30.0206 A Vtrans = 0.300263 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:04:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001166491 Vs 15:04:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001158405 Vs 15:04:20 Magnet Current for MAIN, Imag = 30.0217 A Vtrans = 0.300274 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:04:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168725 Vs 15:04:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001158861 Vs 15:04:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001163293 +- 0.000000506 Vs 15:04:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001163293 +- 0.000000506 Vs BL = -0.01163293 +- 0.00000506 Tm 15:04:39 Position moved: 0.000000 m 15:04:39 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01163 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01163 0.00001 -0.01163 0.00000 15:04:39 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01163 0.00001 SL = -0.0116329 +- 0.0000051 Tm^2/m^n 15:04:39 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0116329 +- 0.0000051 Tm^2/m^n Remeasure 15:04:39 Magnetic Field Measurement Measuring the magnet strength... 15:04:39 Integrated Voltage Measurement... 15:04:40 Magnet Current for MAIN, Imag = 30.0223 A Vtrans = 0.300280 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:04:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001165623 Vs 15:04:56 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001158189 Vs 15:04:57 Magnet Current for MAIN, Imag = 30.0228 A Vtrans = 0.300285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:05:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168740 Vs 15:05:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001152867 Vs 15:05:13 Magnet Current for MAIN, Imag = 30.0228 A Vtrans = 0.300285 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:05:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001171207 Vs 15:05:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001158963 Vs 15:05:29 Magnet Current for MAIN, Imag = 30.0223 A Vtrans = 0.300281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:05:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168956 Vs 15:05:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001158999 Vs 15:05:44 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001162943 +- 0.000001682 Vs 15:05:44 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001162943 +- 0.000001682 Vs BL = -0.01162943 +- 0.00001682 Tm 15:05:48 Position moved: 0.000000 m 15:05:48 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01163 0.00002 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01163 0.00002 -0.01163 0.00000 15:05:48 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01163 0.00002 SL = -0.0116294 +- 0.0000168 Tm^2/m^n 15:05:48 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0116294 +- 0.0000168 Tm^2/m^n Remeasure 15:05:48 Magnetic Field Measurement Measuring the magnet strength... 15:05:48 Integrated Voltage Measurement... 15:05:49 Magnet Current for MAIN, Imag = 30.0230 A Vtrans = 0.300287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:05:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001169968 Vs 15:06:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001151989 Vs 15:06:06 Magnet Current for MAIN, Imag = 30.0230 A Vtrans = 0.300287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:06:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001169158 Vs 15:06:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001154951 Vs 15:06:22 Magnet Current for MAIN, Imag = 30.0233 A Vtrans = 0.300291 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:06:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001170122 Vs 15:06:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001157192 Vs 15:06:37 Magnet Current for MAIN, Imag = 30.0223 A Vtrans = 0.300281 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:06:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001170275 Vs 15:06:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001152387 Vs 15:06:52 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001162005 +- 0.000001030 Vs 15:06:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001162005 +- 0.000001030 Vs BL = -0.01162005 +- 0.00001030 Tm 15:06:56 Position moved: 0.000000 m 15:06:56 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01162 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01162 0.00001 -0.01162 0.00000 15:06:56 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01162 0.00001 SL = -0.0116201 +- 0.0000103 Tm^2/m^n 15:06:56 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0116201 +- 0.0000103 Tm^2/m^n Remeasure 15:06:56 Magnetic Field Measurement Measuring the magnet strength... 15:06:56 Integrated Voltage Measurement... 15:06:57 Magnet Current for MAIN, Imag = 30.0213 A Vtrans = 0.300271 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:07:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001170466 Vs 15:07:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001154763 Vs 15:07:14 Magnet Current for MAIN, Imag = 30.0217 A Vtrans = 0.300274 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:07:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168346 Vs 15:07:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001157487 Vs 15:07:30 Magnet Current for MAIN, Imag = 30.0219 A Vtrans = 0.300277 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:07:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168926 Vs 15:07:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001160870 Vs 15:07:46 Magnet Current for MAIN, Imag = 30.0222 A Vtrans = 0.300279 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:07:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001170263 Vs 15:08:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001154711 Vs 15:08:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001163229 +- 0.000000976 Vs 15:08:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001163229 +- 0.000000976 Vs BL = -0.01163229 +- 0.00000976 Tm 15:08:05 Position moved: 0.000000 m 15:08:05 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01163 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01163 0.00001 -0.01163 0.00000 15:08:05 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01163 0.00001 SL = -0.0116323 +- 0.0000098 Tm^2/m^n 15:08:05 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0116323 +- 0.0000098 Tm^2/m^n Remeasure 15:08:05 Magnetic Field Measurement Measuring the magnet strength... 15:08:05 Integrated Voltage Measurement... 15:08:05 Magnet Current for MAIN, Imag = 30.0229 A Vtrans = 0.300287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:08:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001169983 Vs 15:08:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001156397 Vs 15:08:23 Magnet Current for MAIN, Imag = 30.0226 A Vtrans = 0.300283 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:08:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001167332 Vs 15:08:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001160879 Vs 15:08:39 Magnet Current for MAIN, Imag = 30.0230 A Vtrans = 0.300287 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:08:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001168416 Vs 15:08:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001155723 Vs 15:08:55 Magnet Current for MAIN, Imag = 30.0231 A Vtrans = 0.300288 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:09:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001171275 Vs 15:09:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.001154414 Vs 15:09:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.001163052 +- 0.000000731 Vs 15:09:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.001163052 +- 0.000000731 Vs BL = -0.01163052 +- 0.00000731 Tm 15:09:14 Position moved: 0.000000 m 15:09:14 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.01163 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.01163 0.00001 -0.01163 0.00000 15:09:14 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.01163 0.00001 SL = -0.0116305 +- 0.0000073 Tm^2/m^n 15:09:14 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0116305 +- 0.0000073 Tm^2/m^n 15:09:17 Position moved: 0.000000 m 15:09:17 Magnet system MAIN current ramping to 15.0000 A... 15:09:29 Magnet Current for MAIN, Imag = 14.9924 A Vtrans = 0.149982 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:09:29 MAIN (V) Voltage Measurement, V = 0.591925 V 15:09:33 Temperature Measurement, Probe Number = 0, T = 26.417000 C 15:09:33 Temperature Measurement, Probe Number = 1, T = 27.500000 C 15:09:34 Temperature Measurement, Probe Number = 2, T = 28.075000 C 15:09:35 Temperature Measurement, Probe Number = 3, T = 28.943000 C 15:09:35 Temperature Measurement, Probe Number = 4, T = 28.984000 C 15:09:36 Temperature Measurement, Probe Number = 5, T = 25.663000 C 15:09:36 Sensor Voltage Measurement, Sensor Number = 0, V = 2.666966 V 15:09:36 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.666966 (V, A, ohm, ...), Measured Value = 125.022443 (C, atm, Hz, ...) 15:09:37 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158277 V 15:09:37 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158277 (V, A, ohm, ...), Measured Value = 11.870753 (C, atm, Hz, ...) 15:09:37 Magnet Test Parameter Measurements P0 = MAIN, Value = 14.99 P1 = MAIN (V), Value = 0.59 P2 = Yoke, Value = 26.42 P3 = Bottom Coil, Value = 27.50 P4 = Top Coil, Value = 28.07 P5 = Water In, Value = 28.94 P6 = Water Out, Value = 28.98 P7 = Ambient, Value = 25.66 P8 = Supply Pres(psi), Value = 125.02 P9 = Return Pres(psi), Value = 11.87 15:09:37 Magnetic Field Measurement Measuring the magnet strength... 15:09:37 Integrated Voltage Measurement... 15:09:38 Magnet Current for MAIN, Imag = 14.9920 A Vtrans = 0.149978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:09:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000595993 Vs 15:09:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000583140 Vs 15:09:55 Magnet Current for MAIN, Imag = 14.9920 A Vtrans = 0.149978 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:10:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000594265 Vs 15:10:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581328 Vs 15:10:11 Magnet Current for MAIN, Imag = 14.9918 A Vtrans = 0.149975 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:10:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000596433 Vs 15:10:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581187 Vs 15:10:27 Magnet Current for MAIN, Imag = 14.9914 A Vtrans = 0.149971 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:10:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000593473 Vs 15:10:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581888 Vs 15:10:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588463 +- 0.000000774 Vs 15:10:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000588463 +- 0.000000774 Vs BL = -0.00588463 +- 0.00000774 Tm 15:10:46 Position moved: 0.000000 m 15:10:46 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00588 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00588 0.00001 -0.00588 0.00000 15:10:46 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00588 0.00001 SL = -0.0058846 +- 0.0000077 Tm^2/m^n 15:10:46 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058846 +- 0.0000077 Tm^2/m^n Remeasure 15:10:46 Magnetic Field Measurement Measuring the magnet strength... 15:10:46 Integrated Voltage Measurement... 15:10:46 Magnet Current for MAIN, Imag = 14.9925 A Vtrans = 0.149983 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:10:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000594720 Vs 15:11:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000583450 Vs 15:11:04 Magnet Current for MAIN, Imag = 14.9938 A Vtrans = 0.149995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:11:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000595153 Vs 15:11:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000580212 Vs 15:11:19 Magnet Current for MAIN, Imag = 14.9939 A Vtrans = 0.149997 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:11:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000594502 Vs 15:11:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000583611 Vs 15:11:35 Magnet Current for MAIN, Imag = 14.9936 A Vtrans = 0.149993 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:11:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000595144 Vs 15:11:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581182 Vs 15:11:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588497 +- 0.000000599 Vs 15:11:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000588497 +- 0.000000599 Vs BL = -0.00588497 +- 0.00000599 Tm 15:11:55 Position moved: 0.000000 m 15:11:55 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00588 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00588 0.00001 -0.00588 0.00000 15:11:55 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00588 0.00001 SL = -0.0058850 +- 0.0000060 Tm^2/m^n 15:11:55 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058850 +- 0.0000060 Tm^2/m^n Remeasure 15:11:55 Magnetic Field Measurement Measuring the magnet strength... 15:11:55 Integrated Voltage Measurement... 15:11:55 Magnet Current for MAIN, Imag = 14.9933 A Vtrans = 0.149990 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:12:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000596615 Vs 15:12:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581017 Vs 15:12:12 Magnet Current for MAIN, Imag = 14.9932 A Vtrans = 0.149989 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:12:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000596422 Vs 15:12:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581184 Vs 15:12:28 Magnet Current for MAIN, Imag = 14.9927 A Vtrans = 0.149984 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:12:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000595648 Vs 15:12:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581588 Vs 15:12:44 Magnet Current for MAIN, Imag = 14.9938 A Vtrans = 0.149995 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:12:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000595637 Vs 15:12:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000581655 Vs 15:12:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000588721 +- 0.000000089 Vs 15:12:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000588721 +- 0.000000089 Vs BL = -0.00588721 +- 0.00000089 Tm 15:13:03 Position moved: 0.000000 m 15:13:03 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00589 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00589 0.00000 -0.00589 0.00000 15:13:03 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00589 0.00000 SL = -0.0058872 +- 0.0000009 Tm^2/m^n 15:13:03 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0058872 +- 0.0000009 Tm^2/m^n 15:13:06 Position moved: 0.000000 m 15:13:06 Magnet system MAIN current ramping to 0.0000 A... 15:13:18 Magnet Current for MAIN, Imag = 0.0135 A Vtrans = 0.000193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:13:19 MAIN (V) Voltage Measurement, V = 0.000695 V 15:13:22 Temperature Measurement, Probe Number = 0, T = 26.426000 C 15:13:23 Temperature Measurement, Probe Number = 1, T = 27.513000 C 15:13:23 Temperature Measurement, Probe Number = 2, T = 27.933000 C 15:13:24 Temperature Measurement, Probe Number = 3, T = 28.955000 C 15:13:25 Temperature Measurement, Probe Number = 4, T = 28.990000 C 15:13:25 Temperature Measurement, Probe Number = 5, T = 25.699000 C 15:13:26 Sensor Voltage Measurement, Sensor Number = 0, V = 2.667026 V 15:13:26 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.667026 (V, A, ohm, ...), Measured Value = 125.026943 (C, atm, Hz, ...) 15:13:26 Sensor Voltage Measurement, Sensor Number = 1, V = 1.155550 V 15:13:26 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.155550 (V, A, ohm, ...), Measured Value = 11.666227 (C, atm, Hz, ...) 15:13:26 Magnet Test Parameter Measurements P0 = MAIN, Value = 0.01 P1 = MAIN (V), Value = 0.00 P2 = Yoke, Value = 26.43 P3 = Bottom Coil, Value = 27.51 P4 = Top Coil, Value = 27.93 P5 = Water In, Value = 28.95 P6 = Water Out, Value = 28.99 P7 = Ambient, Value = 25.70 P8 = Supply Pres(psi), Value = 125.03 P9 = Return Pres(psi), Value = 11.67 15:13:26 Magnetic Field Measurement Measuring the magnet strength... 15:13:26 Integrated Voltage Measurement... 15:13:27 Magnet Current for MAIN, Imag = 0.0136 A Vtrans = 0.000193 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:13:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021644 Vs 15:13:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008734 Vs 15:13:44 Magnet Current for MAIN, Imag = 0.0139 A Vtrans = 0.000196 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:13:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000020854 Vs 15:13:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008687 Vs 15:14:00 Magnet Current for MAIN, Imag = 0.0132 A Vtrans = 0.000189 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:14:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000021523 Vs 15:14:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008155 Vs 15:14:16 Magnet Current for MAIN, Imag = 0.0128 A Vtrans = 0.000185 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:14:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000022214 Vs 15:14:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000008464 Vs 15:14:31 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = -0.000015035 +- 0.000000237 Vs 15:14:31 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000015035 +- 0.000000237 Vs BL = -0.00015035 +- 0.00000237 Tm 15:14:35 Position moved: 0.000000 m 15:14:35 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 -0.00015 0.00000 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 -0.00015 0.00000 -0.00015 0.00000 15:14:35 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 -0.00015 0.00000 SL = -0.0001503 +- 0.0000024 Tm^2/m^n 15:14:35 Magnet Strength Measurement Harmonic Number = 1 SL = -0.0001503 +- 0.0000024 Tm^2/m^n 15:14:38 Position moved: 0.000000 m 15:14:38 Magnet system MAIN current ramping to 155.0000 A... 15:15:00 Magnet Current for MAIN, Imag = 154.9642 A Vtrans = 1.549699 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:15:00 MAIN (V) Voltage Measurement, V = 6.143253 V 15:15:04 Temperature Measurement, Probe Number = 0, T = 26.424000 C 15:15:04 Temperature Measurement, Probe Number = 1, T = 27.691000 C 15:15:05 Temperature Measurement, Probe Number = 2, T = 27.944000 C 15:15:06 Temperature Measurement, Probe Number = 3, T = 28.949000 C 15:15:06 Temperature Measurement, Probe Number = 4, T = 29.025000 C 15:15:07 Temperature Measurement, Probe Number = 5, T = 25.699000 C 15:15:07 Sensor Voltage Measurement, Sensor Number = 0, V = 2.670884 V 15:15:07 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.670884 (V, A, ohm, ...), Measured Value = 125.316322 (C, atm, Hz, ...) 15:15:08 Sensor Voltage Measurement, Sensor Number = 1, V = 1.156590 V 15:15:08 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.156590 (V, A, ohm, ...), Measured Value = 11.744235 (C, atm, Hz, ...) 15:15:08 Magnet Test Parameter Measurements P0 = MAIN, Value = 154.96 P1 = MAIN (V), Value = 6.14 P2 = Yoke, Value = 26.42 P3 = Bottom Coil, Value = 27.69 P4 = Top Coil, Value = 27.94 P5 = Water In, Value = 28.95 P6 = Water Out, Value = 29.02 P7 = Ambient, Value = 25.70 P8 = Supply Pres(psi), Value = 125.32 P9 = Return Pres(psi), Value = 11.74 15:15:08 Integrated Voltage Measurement... 15:15:09 Magnet Current for MAIN, Imag = 154.9643 A Vtrans = 1.549701 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:15:17 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657712 Vs 15:15:25 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636215 Vs 15:15:26 Magnet Current for MAIN, Imag = 154.9622 A Vtrans = 1.549679 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:15:34 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654232 Vs 15:15:41 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002633714 Vs 15:15:42 Magnet Current for MAIN, Imag = 154.9626 A Vtrans = 1.549683 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:15:50 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002653749 Vs 15:15:57 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639160 Vs 15:15:58 Magnet Current for MAIN, Imag = 154.9607 A Vtrans = 1.549664 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:16:05 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654273 Vs 15:16:13 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002651898 Vs 15:16:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002647619 +- 0.000003353 Vs 15:16:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002647619 +- 0.000003353 Vs BL = -0.05295238 +- 0.00006705 Tm Remeasure 15:16:13 Integrated Voltage Measurement... 15:16:14 Magnet Current for MAIN, Imag = 154.9601 A Vtrans = 1.549658 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:16:21 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655818 Vs 15:16:29 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002641247 Vs 15:16:29 Magnet Current for MAIN, Imag = 154.9597 A Vtrans = 1.549654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:16:37 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002645767 Vs 15:16:45 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639954 Vs 15:16:45 Magnet Current for MAIN, Imag = 154.9591 A Vtrans = 1.549648 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:16:53 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655768 Vs 15:17:00 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002643082 Vs 15:17:01 Magnet Current for MAIN, Imag = 154.9581 A Vtrans = 1.549638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:17:09 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002653308 Vs 15:17:16 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002634773 Vs 15:17:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002646215 +- 0.000002813 Vs 15:17:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002646215 +- 0.000002813 Vs BL = -0.05292429 +- 0.00005626 Tm Remeasure 15:17:16 Integrated Voltage Measurement... 15:17:17 Magnet Current for MAIN, Imag = 154.9568 A Vtrans = 1.549626 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:17:25 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002658225 Vs 15:17:32 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636475 Vs 15:17:33 Magnet Current for MAIN, Imag = 154.9575 A Vtrans = 1.549632 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:17:41 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002652618 Vs 15:17:48 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636729 Vs 15:17:49 Magnet Current for MAIN, Imag = 154.9565 A Vtrans = 1.549622 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:17:57 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657474 Vs 15:18:04 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002641274 Vs 15:18:05 Magnet Current for MAIN, Imag = 154.9567 A Vtrans = 1.549624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:18:13 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657027 Vs 15:18:20 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002641151 Vs 15:18:20 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002647622 +- 0.000001870 Vs 15:18:20 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002647622 +- 0.000001870 Vs BL = -0.05295244 +- 0.00003740 Tm Remeasure 15:18:20 Integrated Voltage Measurement... 15:18:21 Magnet Current for MAIN, Imag = 154.9550 A Vtrans = 1.549607 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:18:29 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002663705 Vs 15:18:36 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002632105 Vs 15:18:37 Magnet Current for MAIN, Imag = 154.9552 A Vtrans = 1.549610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:18:45 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651923 Vs 15:18:52 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002648217 Vs 15:18:53 Magnet Current for MAIN, Imag = 154.9550 A Vtrans = 1.549607 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:19:01 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659189 Vs 15:19:08 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002650489 Vs 15:19:09 Magnet Current for MAIN, Imag = 154.9541 A Vtrans = 1.549598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:19:17 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002656517 Vs 15:19:24 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640831 Vs 15:19:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002650372 +- 0.000002693 Vs 15:19:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002650372 +- 0.000002693 Vs BL = -0.05300744 +- 0.00005387 Tm Remeasure 15:19:24 Integrated Voltage Measurement... 15:19:25 Magnet Current for MAIN, Imag = 154.9543 A Vtrans = 1.549601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:19:33 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002653159 Vs 15:19:41 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002642390 Vs 15:19:41 Magnet Current for MAIN, Imag = 154.9536 A Vtrans = 1.549593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:19:49 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002660107 Vs 15:19:56 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002648850 Vs 15:19:57 Magnet Current for MAIN, Imag = 154.9545 A Vtrans = 1.549602 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:20:05 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002658786 Vs 15:20:12 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639822 Vs 15:20:13 Magnet Current for MAIN, Imag = 154.9540 A Vtrans = 1.549597 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:20:21 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002652717 Vs 15:20:28 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639569 Vs 15:20:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002649425 +- 0.000003124 Vs 15:20:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002649425 +- 0.000003124 Vs BL = -0.05298850 +- 0.00006249 Tm 15:20:28 Integrated Voltage Measurement... 15:20:29 Magnet Current for MAIN, Imag = 154.9541 A Vtrans = 1.549598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:20:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002820457 Vs 15:20:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002806137 Vs 15:20:46 Magnet Current for MAIN, Imag = 154.9542 A Vtrans = 1.549600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:20:54 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002818076 Vs 15:21:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801965 Vs 15:21:02 Magnet Current for MAIN, Imag = 154.9537 A Vtrans = 1.549594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:21:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002814154 Vs 15:21:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002798003 Vs 15:21:18 Magnet Current for MAIN, Imag = 154.9536 A Vtrans = 1.549593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:21:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002813697 Vs 15:21:33 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002806703 Vs 15:21:33 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002809899 +- 0.000002562 Vs 15:21:33 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002809899 +- 0.000002562 Vs BL = -0.05619798 +- 0.00005124 Tm Remeasure 15:21:33 Integrated Voltage Measurement... 15:21:34 Magnet Current for MAIN, Imag = 154.9536 A Vtrans = 1.549593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:21:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002813972 Vs 15:21:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002806376 Vs 15:21:50 Magnet Current for MAIN, Imag = 154.9541 A Vtrans = 1.549598 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:21:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002817457 Vs 15:22:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801952 Vs 15:22:06 Magnet Current for MAIN, Imag = 154.9536 A Vtrans = 1.549593 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:22:13 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815251 Vs 15:22:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002806902 Vs 15:22:22 Magnet Current for MAIN, Imag = 154.9537 A Vtrans = 1.549594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:22:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002818025 Vs 15:22:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002804116 Vs 15:22:37 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002810506 +- 0.000000591 Vs 15:22:37 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002810506 +- 0.000000591 Vs BL = -0.05621013 +- 0.00001182 Tm 15:22:37 Integrated Voltage Measurement... 15:22:38 Magnet Current for MAIN, Imag = 154.9535 A Vtrans = 1.549592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:22:46 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002892858 Vs 15:22:54 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002889901 Vs 15:22:54 Magnet Current for MAIN, Imag = 154.9538 A Vtrans = 1.549596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:23:02 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002895531 Vs 15:23:10 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885016 Vs 15:23:10 Magnet Current for MAIN, Imag = 154.9538 A Vtrans = 1.549596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:23:18 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002900431 Vs 15:23:26 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002881403 Vs 15:23:26 Magnet Current for MAIN, Imag = 154.9535 A Vtrans = 1.549592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:23:34 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002895964 Vs 15:23:41 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002889163 Vs 15:23:41 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002891283 +- 0.000000837 Vs 15:23:41 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002891283 +- 0.000000837 Vs BL = -0.05782566 +- 0.00001674 Tm Remeasure 15:23:41 Integrated Voltage Measurement... 15:23:42 Magnet Current for MAIN, Imag = 154.9533 A Vtrans = 1.549591 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:23:50 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896918 Vs 15:23:57 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002882692 Vs 15:23:58 Magnet Current for MAIN, Imag = 154.9537 A Vtrans = 1.549594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:24:06 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002903586 Vs 15:24:13 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887241 Vs 15:24:14 Magnet Current for MAIN, Imag = 154.9535 A Vtrans = 1.549592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:24:21 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002895591 Vs 15:24:29 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886023 Vs 15:24:30 Magnet Current for MAIN, Imag = 154.9538 A Vtrans = 1.549596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:24:37 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002899685 Vs 15:24:45 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002882824 Vs 15:24:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002891820 +- 0.000002140 Vs 15:24:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002891820 +- 0.000002140 Vs BL = -0.05783640 +- 0.00004280 Tm Remeasure 15:24:45 Integrated Voltage Measurement... 15:24:46 Magnet Current for MAIN, Imag = 154.9535 A Vtrans = 1.549592 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:24:54 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002898061 Vs 15:25:01 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885447 Vs 15:25:02 Magnet Current for MAIN, Imag = 154.9537 A Vtrans = 1.549594 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:25:09 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896597 Vs 15:25:17 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002883884 Vs 15:25:18 Magnet Current for MAIN, Imag = 154.9540 A Vtrans = 1.549597 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:25:25 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002897323 Vs 15:25:33 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885266 Vs 15:25:34 Magnet Current for MAIN, Imag = 154.9542 A Vtrans = 1.549600 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:25:42 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002898280 Vs 15:25:49 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887614 Vs 15:25:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002891559 +- 0.000000971 Vs 15:25:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002891559 +- 0.000000971 Vs BL = -0.05783118 +- 0.00001943 Tm 15:25:49 Integrated Voltage Measurement... 15:25:50 Magnet Current for MAIN, Imag = 154.9538 A Vtrans = 1.549596 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:25:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002940604 Vs 15:26:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923614 Vs 15:26:07 Magnet Current for MAIN, Imag = 154.9543 A Vtrans = 1.549601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:26:15 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002931486 Vs 15:26:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002929571 Vs 15:26:23 Magnet Current for MAIN, Imag = 154.9543 A Vtrans = 1.549601 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:26:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002927766 Vs 15:26:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922799 Vs 15:26:39 Magnet Current for MAIN, Imag = 154.9545 A Vtrans = 1.549602 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:26:47 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002954693 Vs 15:26:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923571 Vs 15:26:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002931763 +- 0.000004948 Vs 15:26:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002931763 +- 0.000004948 Vs BL = -0.05863526 +- 0.00009897 Tm Remeasure 15:26:54 Integrated Voltage Measurement... 15:26:55 Magnet Current for MAIN, Imag = 154.9548 A Vtrans = 1.549606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:27:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002931027 Vs 15:27:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919641 Vs 15:27:11 Magnet Current for MAIN, Imag = 154.9552 A Vtrans = 1.549610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:27:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002954201 Vs 15:27:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923185 Vs 15:27:27 Magnet Current for MAIN, Imag = 154.9548 A Vtrans = 1.549606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:27:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002934504 Vs 15:27:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924210 Vs 15:27:43 Magnet Current for MAIN, Imag = 154.9545 A Vtrans = 1.549602 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:27:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935716 Vs 15:27:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002932334 Vs 15:27:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002931852 +- 0.000005006 Vs 15:27:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002931852 +- 0.000005006 Vs BL = -0.05863705 +- 0.00010012 Tm Remeasure 15:27:58 Integrated Voltage Measurement... 15:27:58 Magnet Current for MAIN, Imag = 154.9548 A Vtrans = 1.549606 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:28:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002940188 Vs 15:28:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923958 Vs 15:28:14 Magnet Current for MAIN, Imag = 154.9553 A Vtrans = 1.549611 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:28:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002945236 Vs 15:28:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922415 Vs 15:28:30 Magnet Current for MAIN, Imag = 154.9558 A Vtrans = 1.549616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:28:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002941705 Vs 15:28:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002927353 Vs 15:28:46 Magnet Current for MAIN, Imag = 154.9558 A Vtrans = 1.549616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:28:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002928983 Vs 15:29:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002927280 Vs 15:29:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002932140 +- 0.000002481 Vs 15:29:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932140 +- 0.000002481 Vs BL = -0.05864279 +- 0.00004962 Tm Remeasure 15:29:01 Integrated Voltage Measurement... 15:29:02 Magnet Current for MAIN, Imag = 154.9555 A Vtrans = 1.549612 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:29:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935424 Vs 15:29:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924854 Vs 15:29:18 Magnet Current for MAIN, Imag = 154.9552 A Vtrans = 1.549610 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:29:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002934627 Vs 15:29:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002920400 Vs 15:29:34 Magnet Current for MAIN, Imag = 154.9560 A Vtrans = 1.549617 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:29:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002946155 Vs 15:29:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924852 Vs 15:29:50 Magnet Current for MAIN, Imag = 154.9558 A Vtrans = 1.549616 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:29:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002933130 Vs 15:30:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002918821 Vs 15:30:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002929783 +- 0.000003623 Vs 15:30:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002929783 +- 0.000003623 Vs BL = -0.05859566 +- 0.00007246 Tm Remeasure 15:30:06 Integrated Voltage Measurement... 15:30:06 Magnet Current for MAIN, Imag = 154.9557 A Vtrans = 1.549614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:30:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937471 Vs 15:30:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924261 Vs 15:30:22 Magnet Current for MAIN, Imag = 154.9557 A Vtrans = 1.549614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:30:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937610 Vs 15:30:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002926821 Vs 15:30:38 Magnet Current for MAIN, Imag = 154.9557 A Vtrans = 1.549614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:30:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939736 Vs 15:30:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919546 Vs 15:30:54 Magnet Current for MAIN, Imag = 154.9557 A Vtrans = 1.549614 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:31:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939412 Vs 15:31:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002926275 Vs 15:31:09 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002931392 +- 0.000001238 Vs 15:31:09 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002931392 +- 0.000001238 Vs BL = -0.05862783 +- 0.00002476 Tm 15:31:09 Integrated Voltage Measurement... 15:31:10 Magnet Current for MAIN, Imag = 154.9561 A Vtrans = 1.549618 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:31:19 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954054 Vs 15:31:26 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002923810 Vs 15:31:27 Magnet Current for MAIN, Imag = 154.9567 A Vtrans = 1.549624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:31:35 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953490 Vs 15:31:42 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002931127 Vs 15:31:43 Magnet Current for MAIN, Imag = 154.9567 A Vtrans = 1.549624 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:31:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955364 Vs 15:31:58 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002948424 Vs 15:31:59 Magnet Current for MAIN, Imag = 154.9563 A Vtrans = 1.549621 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:32:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953457 Vs 15:32:14 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002945818 Vs 15:32:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002945693 +- 0.000005272 Vs 15:32:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002945693 +- 0.000005272 Vs BL = -0.05891386 +- 0.00010544 Tm Remeasure 15:32:14 Integrated Voltage Measurement... 15:32:15 Magnet Current for MAIN, Imag = 154.9566 A Vtrans = 1.549623 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:32:22 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957824 Vs 15:32:30 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944837 Vs 15:32:31 Magnet Current for MAIN, Imag = 154.9570 A Vtrans = 1.549627 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:32:38 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955421 Vs 15:32:46 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002935438 Vs 15:32:47 Magnet Current for MAIN, Imag = 154.9577 A Vtrans = 1.549635 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:32:54 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002958084 Vs 15:33:02 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002931215 Vs 15:33:03 Magnet Current for MAIN, Imag = 154.9576 A Vtrans = 1.549633 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:33:10 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002952418 Vs 15:33:18 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002946722 Vs 15:33:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002947745 +- 0.000002790 Vs 15:33:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947745 +- 0.000002790 Vs BL = -0.05895490 +- 0.00005580 Tm Remeasure 15:33:18 Integrated Voltage Measurement... 15:33:19 Magnet Current for MAIN, Imag = 154.9580 A Vtrans = 1.549637 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:33:27 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955898 Vs 15:33:34 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002933352 Vs 15:33:35 Magnet Current for MAIN, Imag = 154.9581 A Vtrans = 1.549638 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:33:43 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956328 Vs 15:33:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002949170 Vs 15:33:51 Magnet Current for MAIN, Imag = 154.9583 A Vtrans = 1.549641 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:33:58 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956225 Vs 15:34:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002954028 Vs 15:34:06 Magnet Current for MAIN, Imag = 154.9578 A Vtrans = 1.549636 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:34:14 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953581 Vs 15:34:22 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002937650 Vs 15:34:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002949529 +- 0.000004502 Vs 15:34:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002949529 +- 0.000004502 Vs BL = -0.05899058 +- 0.00009004 Tm Remeasure 15:34:22 Integrated Voltage Measurement... 15:34:22 Magnet Current for MAIN, Imag = 154.9582 A Vtrans = 1.549640 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:34:30 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002951676 Vs 15:34:38 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002937436 Vs 15:34:38 Magnet Current for MAIN, Imag = 154.9585 A Vtrans = 1.549642 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:34:46 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954798 Vs 15:34:54 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002936891 Vs 15:34:54 Magnet Current for MAIN, Imag = 154.9588 A Vtrans = 1.549646 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:35:02 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956561 Vs 15:35:10 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002957921 Vs 15:35:10 Magnet Current for MAIN, Imag = 154.9588 A Vtrans = 1.549646 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:35:18 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002949529 Vs 15:35:26 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002951288 Vs 15:35:26 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002949513 +- 0.000004964 Vs 15:35:26 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002949513 +- 0.000004964 Vs BL = -0.05899025 +- 0.00009927 Tm Remeasure 15:35:26 Integrated Voltage Measurement... 15:35:26 Magnet Current for MAIN, Imag = 154.9597 A Vtrans = 1.549654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:35:34 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002952246 Vs 15:35:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002927771 Vs 15:35:42 Magnet Current for MAIN, Imag = 154.9592 A Vtrans = 1.549649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:35:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002950202 Vs 15:35:57 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002957266 Vs 15:35:58 Magnet Current for MAIN, Imag = 154.9592 A Vtrans = 1.549649 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:36:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954785 Vs 15:36:13 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944534 Vs 15:36:14 Magnet Current for MAIN, Imag = 154.9602 A Vtrans = 1.549659 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:36:22 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953788 Vs 15:36:29 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944865 Vs 15:36:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002948182 +- 0.000005028 Vs 15:36:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002948182 +- 0.000005028 Vs BL = -0.05896364 +- 0.00010056 Tm 15:36:29 Integrated Voltage Measurement... 15:36:30 Magnet Current for MAIN, Imag = 154.9605 A Vtrans = 1.549662 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:36:39 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959364 Vs 15:36:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945137 Vs 15:36:47 Magnet Current for MAIN, Imag = 154.9603 A Vtrans = 1.549661 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:36:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002955408 Vs 15:37:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945548 Vs 15:37:03 Magnet Current for MAIN, Imag = 154.9600 A Vtrans = 1.549657 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:37:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960461 Vs 15:37:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002949152 Vs 15:37:19 Magnet Current for MAIN, Imag = 154.9597 A Vtrans = 1.549654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:37:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002955086 Vs 15:37:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943650 Vs 15:37:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002951726 +- 0.000002054 Vs 15:37:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951726 +- 0.000002054 Vs BL = -0.05903451 +- 0.00004109 Tm Remeasure 15:37:34 Integrated Voltage Measurement... 15:37:34 Magnet Current for MAIN, Imag = 154.9597 A Vtrans = 1.549654 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:37:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959929 Vs 15:37:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944236 Vs 15:37:50 Magnet Current for MAIN, Imag = 154.9608 A Vtrans = 1.549666 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:37:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002963175 Vs 15:38:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945602 Vs 15:38:06 Magnet Current for MAIN, Imag = 154.9593 A Vtrans = 1.549651 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:38:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002956267 Vs 15:38:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945333 Vs 15:38:22 Magnet Current for MAIN, Imag = 154.9595 A Vtrans = 1.549652 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:38:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958415 Vs 15:38:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943461 Vs 15:38:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002952052 +- 0.000001438 Vs 15:38:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952052 +- 0.000001438 Vs BL = -0.05904105 +- 0.00002876 Tm Remeasure 15:38:38 Integrated Voltage Measurement... 15:38:38 Magnet Current for MAIN, Imag = 154.9611 A Vtrans = 1.549668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:38:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959164 Vs 15:38:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002941963 Vs 15:38:54 Magnet Current for MAIN, Imag = 154.9617 A Vtrans = 1.549674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:39:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958557 Vs 15:39:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002940622 Vs 15:39:10 Magnet Current for MAIN, Imag = 154.9608 A Vtrans = 1.549666 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:39:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958240 Vs 15:39:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943183 Vs 15:39:26 Magnet Current for MAIN, Imag = 154.9602 A Vtrans = 1.549659 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:39:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960490 Vs 15:39:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944457 Vs 15:39:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002950835 +- 0.000001040 Vs 15:39:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950835 +- 0.000001040 Vs BL = -0.05901669 +- 0.00002080 Tm Remeasure 15:39:42 Integrated Voltage Measurement... 15:39:42 Magnet Current for MAIN, Imag = 154.9606 A Vtrans = 1.549663 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:39:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958165 Vs 15:39:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943792 Vs 15:39:58 Magnet Current for MAIN, Imag = 154.9611 A Vtrans = 1.549668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:40:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960825 Vs 15:40:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002939174 Vs 15:40:14 Magnet Current for MAIN, Imag = 154.9612 A Vtrans = 1.549669 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:40:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957705 Vs 15:40:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944572 Vs 15:40:30 Magnet Current for MAIN, Imag = 154.9611 A Vtrans = 1.549668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:40:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002962397 Vs 15:40:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945043 Vs 15:40:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002951459 +- 0.000001376 Vs 15:40:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951459 +- 0.000001376 Vs BL = -0.05902918 +- 0.00002753 Tm 15:40:45 Integrated Voltage Measurement... 15:40:46 Magnet Current for MAIN, Imag = 154.9613 A Vtrans = 1.549671 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:40:55 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002961696 Vs 15:41:02 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948916 Vs 15:41:03 Magnet Current for MAIN, Imag = 154.9615 A Vtrans = 1.549672 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:41:11 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002958386 Vs 15:41:18 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002944926 Vs 15:41:19 Magnet Current for MAIN, Imag = 154.9613 A Vtrans = 1.549671 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:41:27 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002961688 Vs 15:41:34 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002945626 Vs 15:41:35 Magnet Current for MAIN, Imag = 154.9616 A Vtrans = 1.549673 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:41:43 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002962821 Vs 15:41:50 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946083 Vs 15:41:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002953768 +- 0.000001351 Vs 15:41:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953768 +- 0.000001351 Vs BL = -0.05907535 +- 0.00002703 Tm Remeasure 15:41:50 Integrated Voltage Measurement... 15:41:51 Magnet Current for MAIN, Imag = 154.9621 A Vtrans = 1.549678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:41:58 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002953502 Vs 15:42:06 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947436 Vs 15:42:07 Magnet Current for MAIN, Imag = 154.9620 A Vtrans = 1.549677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:42:14 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959230 Vs 15:42:22 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002945252 Vs 15:42:23 Magnet Current for MAIN, Imag = 154.9611 A Vtrans = 1.549668 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:42:30 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002963260 Vs 15:42:38 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947054 Vs 15:42:39 Magnet Current for MAIN, Imag = 154.9613 A Vtrans = 1.549671 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:42:46 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002956676 Vs 15:42:54 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947819 Vs 15:42:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952529 +- 0.000001682 Vs 15:42:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952529 +- 0.000001682 Vs BL = -0.05905057 +- 0.00003363 Tm Remeasure 15:42:54 Integrated Voltage Measurement... 15:42:55 Magnet Current for MAIN, Imag = 154.9617 A Vtrans = 1.549674 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:43:02 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002953609 Vs 15:43:10 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947450 Vs 15:43:11 Magnet Current for MAIN, Imag = 154.9616 A Vtrans = 1.549673 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:43:18 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002960369 Vs 15:43:26 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002945703 Vs 15:43:27 Magnet Current for MAIN, Imag = 154.9620 A Vtrans = 1.549677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:43:34 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002958841 Vs 15:43:42 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002945340 Vs 15:43:42 Magnet Current for MAIN, Imag = 154.9631 A Vtrans = 1.549688 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:43:50 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002960527 Vs 15:43:58 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946863 Vs 15:43:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952338 +- 0.000001189 Vs 15:43:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952338 +- 0.000001189 Vs BL = -0.05904675 +- 0.00002379 Tm Remeasure 15:43:58 Integrated Voltage Measurement... 15:43:58 Magnet Current for MAIN, Imag = 154.9625 A Vtrans = 1.549682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:44:06 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002958765 Vs 15:44:13 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002943839 Vs 15:44:14 Magnet Current for MAIN, Imag = 154.9623 A Vtrans = 1.549681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:44:22 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959303 Vs 15:44:29 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002942163 Vs 15:44:30 Magnet Current for MAIN, Imag = 154.9618 A Vtrans = 1.549676 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:44:38 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002957420 Vs 15:44:45 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948867 Vs 15:44:46 Magnet Current for MAIN, Imag = 154.9623 A Vtrans = 1.549681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:44:53 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959639 Vs 15:45:01 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002945477 Vs 15:45:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002951934 +- 0.000000961 Vs 15:45:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951934 +- 0.000000961 Vs BL = -0.05903868 +- 0.00001922 Tm 15:45:01 Integrated Voltage Measurement... 15:45:02 Magnet Current for MAIN, Imag = 154.9620 A Vtrans = 1.549677 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:45:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002963453 Vs 15:45:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002940726 Vs 15:45:19 Magnet Current for MAIN, Imag = 154.9625 A Vtrans = 1.549682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:45:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002961568 Vs 15:45:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002950429 Vs 15:45:35 Magnet Current for MAIN, Imag = 154.9628 A Vtrans = 1.549686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:45:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002962037 Vs 15:45:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002949603 Vs 15:45:50 Magnet Current for MAIN, Imag = 154.9631 A Vtrans = 1.549688 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:45:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002957705 Vs 15:46:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944165 Vs 15:46:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953711 +- 0.000002237 Vs 15:46:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953711 +- 0.000002237 Vs BL = -0.05907421 +- 0.00004474 Tm Remeasure 15:46:06 Integrated Voltage Measurement... 15:46:06 Magnet Current for MAIN, Imag = 154.9621 A Vtrans = 1.549678 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002962095 Vs 15:46:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947617 Vs 15:46:23 Magnet Current for MAIN, Imag = 154.9628 A Vtrans = 1.549686 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959669 Vs 15:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002946832 Vs 15:46:38 Magnet Current for MAIN, Imag = 154.9623 A Vtrans = 1.549681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:46:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959652 Vs 15:46:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944235 Vs 15:46:54 Magnet Current for MAIN, Imag = 154.9623 A Vtrans = 1.549681 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002957453 Vs 15:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002948191 Vs 15:47:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953218 +- 0.000001056 Vs 15:47:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953218 +- 0.000001056 Vs BL = -0.05906436 +- 0.00002113 Tm Remeasure 15:47:10 Integrated Voltage Measurement... 15:47:10 Magnet Current for MAIN, Imag = 154.9625 A Vtrans = 1.549682 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002956384 Vs 15:47:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947744 Vs 15:47:26 Magnet Current for MAIN, Imag = 154.9635 A Vtrans = 1.549692 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:47:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002956322 Vs 15:47:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002950647 Vs 15:47:42 Magnet Current for MAIN, Imag = 154.9632 A Vtrans = 1.549689 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:47:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002958551 Vs 15:47:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947783 Vs 15:47:58 Magnet Current for MAIN, Imag = 154.9632 A Vtrans = 1.549689 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:48:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002968186 Vs 15:48:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002946701 Vs 15:48:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002954040 +- 0.000002035 Vs 15:48:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002954040 +- 0.000002035 Vs BL = -0.05908079 +- 0.00004069 Tm Remeasure 15:48:13 Integrated Voltage Measurement... 15:48:14 Magnet Current for MAIN, Imag = 154.9635 A Vtrans = 1.549692 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:48:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002962351 Vs 15:48:29 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944721 Vs 15:48:30 Magnet Current for MAIN, Imag = 154.9627 A Vtrans = 1.549684 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:48:37 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002956293 Vs 15:48:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002945886 Vs 15:48:46 Magnet Current for MAIN, Imag = 154.9630 A Vtrans = 1.549687 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:48:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960747 Vs 15:49:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002941234 Vs 15:49:02 Magnet Current for MAIN, Imag = 154.9627 A Vtrans = 1.549684 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:49:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002964238 Vs 15:49:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002945591 Vs 15:49:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002952632 +- 0.000001666 Vs 15:49:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952632 +- 0.000001666 Vs BL = -0.05905265 +- 0.00003332 Tm Remeasure 15:49:17 Integrated Voltage Measurement... 15:49:18 Magnet Current for MAIN, Imag = 154.9637 A Vtrans = 1.549694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:49:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002958962 Vs 15:49:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002942754 Vs 15:49:34 Magnet Current for MAIN, Imag = 154.9648 A Vtrans = 1.549706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:49:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960827 Vs 15:49:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002943535 Vs 15:49:49 Magnet Current for MAIN, Imag = 154.9636 A Vtrans = 1.549693 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:49:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002958810 Vs 15:50:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002948602 Vs 15:50:05 Magnet Current for MAIN, Imag = 154.9645 A Vtrans = 1.549702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:50:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002956104 Vs 15:50:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947397 Vs 15:50:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002952124 +- 0.000001031 Vs 15:50:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952124 +- 0.000001031 Vs BL = -0.05904248 +- 0.00002061 Tm 15:50:21 Integrated Voltage Measurement... 15:50:21 Magnet Current for MAIN, Imag = 154.9647 A Vtrans = 1.549704 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:50:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002966548 Vs 15:50:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002944747 Vs 15:50:38 Magnet Current for MAIN, Imag = 154.9641 A Vtrans = 1.549698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:50:46 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002955607 Vs 15:50:54 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002942929 Vs 15:50:54 Magnet Current for MAIN, Imag = 154.9643 A Vtrans = 1.549701 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:51:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957761 Vs 15:51:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947305 Vs 15:51:10 Magnet Current for MAIN, Imag = 154.9641 A Vtrans = 1.549698 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:51:18 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961699 Vs 15:51:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002949511 Vs 15:51:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953263 +- 0.000002630 Vs 15:51:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953263 +- 0.000002630 Vs BL = -0.05906527 +- 0.00005259 Tm Remeasure 15:51:26 Integrated Voltage Measurement... 15:51:26 Magnet Current for MAIN, Imag = 154.9637 A Vtrans = 1.549694 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:51:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959387 Vs 15:51:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002944754 Vs 15:51:42 Magnet Current for MAIN, Imag = 154.9640 A Vtrans = 1.549697 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:51:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957615 Vs 15:51:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002939073 Vs 15:51:58 Magnet Current for MAIN, Imag = 154.9646 A Vtrans = 1.549703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:52:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958329 Vs 15:52:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947779 Vs 15:52:14 Magnet Current for MAIN, Imag = 154.9647 A Vtrans = 1.549704 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:52:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957671 Vs 15:52:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947511 Vs 15:52:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002951515 +- 0.000001863 Vs 15:52:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951515 +- 0.000001863 Vs BL = -0.05903030 +- 0.00003727 Tm Remeasure 15:52:29 Integrated Voltage Measurement... 15:52:30 Magnet Current for MAIN, Imag = 154.9648 A Vtrans = 1.549706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:52:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959902 Vs 15:52:45 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002943793 Vs 15:52:46 Magnet Current for MAIN, Imag = 154.9643 A Vtrans = 1.549701 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:52:54 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002964049 Vs 15:53:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002946230 Vs 15:53:02 Magnet Current for MAIN, Imag = 154.9642 A Vtrans = 1.549699 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:53:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002963558 Vs 15:53:17 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002946786 Vs 15:53:18 Magnet Current for MAIN, Imag = 154.9648 A Vtrans = 1.549706 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:53:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957356 Vs 15:53:33 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002949095 Vs 15:53:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953846 +- 0.000001397 Vs 15:53:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953846 +- 0.000001397 Vs BL = -0.05907692 +- 0.00002795 Tm Remeasure 15:53:33 Integrated Voltage Measurement... 15:53:34 Magnet Current for MAIN, Imag = 154.9642 A Vtrans = 1.549699 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:53:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958816 Vs 15:53:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002946137 Vs 15:53:50 Magnet Current for MAIN, Imag = 154.9645 A Vtrans = 1.549702 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:53:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962279 Vs 15:54:05 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945803 Vs 15:54:06 Magnet Current for MAIN, Imag = 154.9646 A Vtrans = 1.549703 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:54:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958793 Vs 15:54:21 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945734 Vs 15:54:22 Magnet Current for MAIN, Imag = 154.9642 A Vtrans = 1.549699 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:54:29 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962344 Vs 15:54:37 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945405 Vs 15:54:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953164 +- 0.000000800 Vs 15:54:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953164 +- 0.000000800 Vs BL = -0.05906328 +- 0.00001599 Tm 15:54:37 Integrated Voltage Measurement... 15:54:38 Magnet Current for MAIN, Imag = 154.9650 A Vtrans = 1.549707 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:54:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002965221 Vs 15:54:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943506 Vs 15:54:55 Magnet Current for MAIN, Imag = 154.9652 A Vtrans = 1.549709 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:55:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002956713 Vs 15:55:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002941988 Vs 15:55:11 Magnet Current for MAIN, Imag = 154.9656 A Vtrans = 1.549713 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:55:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002960098 Vs 15:55:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002944185 Vs 15:55:27 Magnet Current for MAIN, Imag = 154.9663 A Vtrans = 1.549721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:55:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002959694 Vs 15:55:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943981 Vs 15:55:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002951923 +- 0.000001777 Vs 15:55:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951923 +- 0.000001777 Vs BL = -0.05903846 +- 0.00003554 Tm Remeasure 15:55:42 Integrated Voltage Measurement... 15:55:43 Magnet Current for MAIN, Imag = 154.9657 A Vtrans = 1.549714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:55:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002957033 Vs 15:55:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942096 Vs 15:55:59 Magnet Current for MAIN, Imag = 154.9658 A Vtrans = 1.549716 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:56:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002960467 Vs 15:56:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002944917 Vs 15:56:15 Magnet Current for MAIN, Imag = 154.9660 A Vtrans = 1.549717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:56:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002958486 Vs 15:56:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942397 Vs 15:56:31 Magnet Current for MAIN, Imag = 154.9657 A Vtrans = 1.549714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:56:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002955324 Vs 15:56:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943176 Vs 15:56:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002950487 +- 0.000001346 Vs 15:56:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950487 +- 0.000001346 Vs BL = -0.05900974 +- 0.00002692 Tm Remeasure 15:56:46 Integrated Voltage Measurement... 15:56:46 Magnet Current for MAIN, Imag = 154.9657 A Vtrans = 1.549714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:56:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002957859 Vs 15:57:01 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943178 Vs 15:57:02 Magnet Current for MAIN, Imag = 154.9657 A Vtrans = 1.549714 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:57:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002957459 Vs 15:57:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002945675 Vs 15:57:18 Magnet Current for MAIN, Imag = 154.9655 A Vtrans = 1.549712 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:57:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002953795 Vs 15:57:33 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002945811 Vs 15:57:34 Magnet Current for MAIN, Imag = 154.9663 A Vtrans = 1.549721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:57:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002955927 Vs 15:57:49 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002945534 Vs 15:57:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002950655 +- 0.000000629 Vs 15:57:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950655 +- 0.000000629 Vs BL = -0.05901310 +- 0.00001258 Tm 15:57:49 Integrated Voltage Measurement... 15:57:50 Magnet Current for MAIN, Imag = 154.9665 A Vtrans = 1.549722 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:57:58 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002950980 Vs 15:58:06 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938509 Vs 15:58:07 Magnet Current for MAIN, Imag = 154.9660 A Vtrans = 1.549717 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:58:14 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953081 Vs 15:58:22 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938392 Vs 15:58:22 Magnet Current for MAIN, Imag = 154.9663 A Vtrans = 1.549721 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:58:30 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951461 Vs 15:58:37 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002942620 Vs 15:58:38 Magnet Current for MAIN, Imag = 154.9676 A Vtrans = 1.549733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:58:46 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954672 Vs 15:58:53 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002940720 Vs 15:58:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002946304 +- 0.000001144 Vs 15:58:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946304 +- 0.000001144 Vs BL = -0.05892609 +- 0.00002288 Tm Remeasure 15:58:53 Integrated Voltage Measurement... 15:58:54 Magnet Current for MAIN, Imag = 154.9672 A Vtrans = 1.549729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:59:02 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954958 Vs 15:59:09 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002941488 Vs 15:59:10 Magnet Current for MAIN, Imag = 154.9676 A Vtrans = 1.549733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:59:18 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002952528 Vs 15:59:25 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938467 Vs 15:59:26 Magnet Current for MAIN, Imag = 154.9675 A Vtrans = 1.549732 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:59:34 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002955069 Vs 15:59:41 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002935777 Vs 15:59:42 Magnet Current for MAIN, Imag = 154.9675 A Vtrans = 1.549732 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 15:59:50 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002950115 Vs 15:59:57 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002942391 Vs 15:59:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002946349 +- 0.000001130 Vs 15:59:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946349 +- 0.000001130 Vs BL = -0.05892699 +- 0.00002259 Tm Remeasure 15:59:57 Integrated Voltage Measurement... 15:59:58 Magnet Current for MAIN, Imag = 154.9668 A Vtrans = 1.549726 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:00:06 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002956653 Vs 16:00:13 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002943136 Vs 16:00:14 Magnet Current for MAIN, Imag = 154.9670 A Vtrans = 1.549727 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:00:21 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951624 Vs 16:00:29 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002942374 Vs 16:00:30 Magnet Current for MAIN, Imag = 154.9672 A Vtrans = 1.549729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:00:37 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002949718 Vs 16:00:45 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002934248 Vs 16:00:45 Magnet Current for MAIN, Imag = 154.9671 A Vtrans = 1.549728 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:00:53 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002950451 Vs 16:01:00 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002937752 Vs 16:01:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002945744 +- 0.000002985 Vs 16:01:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002945744 +- 0.000002985 Vs BL = -0.05891489 +- 0.00005970 Tm Remeasure 16:01:01 Integrated Voltage Measurement... 16:01:01 Magnet Current for MAIN, Imag = 154.9661 A Vtrans = 1.549718 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:01:09 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954955 Vs 16:01:17 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938880 Vs 16:01:17 Magnet Current for MAIN, Imag = 154.9678 A Vtrans = 1.549736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:01:25 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002955538 Vs 16:01:33 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938506 Vs 16:01:33 Magnet Current for MAIN, Imag = 154.9677 A Vtrans = 1.549734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:01:41 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953106 Vs 16:01:48 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002940854 Vs 16:01:49 Magnet Current for MAIN, Imag = 154.9680 A Vtrans = 1.549737 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:01:57 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954278 Vs 16:02:04 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938086 Vs 16:02:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002946775 +- 0.000000345 Vs 16:02:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946775 +- 0.000000345 Vs BL = -0.05893551 +- 0.00000690 Tm 16:02:04 Integrated Voltage Measurement... 16:02:05 Magnet Current for MAIN, Imag = 154.9675 A Vtrans = 1.549732 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:02:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936142 Vs 16:02:21 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002917821 Vs 16:02:22 Magnet Current for MAIN, Imag = 154.9671 A Vtrans = 1.549728 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:02:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002942611 Vs 16:02:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002925585 Vs 16:02:38 Magnet Current for MAIN, Imag = 154.9678 A Vtrans = 1.549736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:02:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936947 Vs 16:02:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923477 Vs 16:02:54 Magnet Current for MAIN, Imag = 154.9673 A Vtrans = 1.549731 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:03:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940506 Vs 16:03:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002927486 Vs 16:03:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002931322 +- 0.000002955 Vs 16:03:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002931322 +- 0.000002955 Vs BL = -0.05862644 +- 0.00005909 Tm Remeasure 16:03:09 Integrated Voltage Measurement... 16:03:10 Magnet Current for MAIN, Imag = 154.9672 A Vtrans = 1.549729 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:03:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002945077 Vs 16:03:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002921472 Vs 16:03:25 Magnet Current for MAIN, Imag = 154.9676 A Vtrans = 1.549733 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:03:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002943756 Vs 16:03:41 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923365 Vs 16:03:41 Magnet Current for MAIN, Imag = 154.9677 A Vtrans = 1.549734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:03:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939939 Vs 16:03:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924427 Vs 16:03:57 Magnet Current for MAIN, Imag = 154.9682 A Vtrans = 1.549739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:04:05 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939216 Vs 16:04:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924532 Vs 16:04:12 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002932723 +- 0.000000710 Vs 16:04:12 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932723 +- 0.000000710 Vs BL = -0.05865446 +- 0.00001421 Tm 16:04:12 Integrated Voltage Measurement... 16:04:13 Magnet Current for MAIN, Imag = 154.9671 A Vtrans = 1.549728 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:04:21 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902275 Vs 16:04:29 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884953 Vs 16:04:30 Magnet Current for MAIN, Imag = 154.9677 A Vtrans = 1.549734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:04:37 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904790 Vs 16:04:45 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887217 Vs 16:04:46 Magnet Current for MAIN, Imag = 154.9677 A Vtrans = 1.549734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:04:53 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902626 Vs 16:05:01 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885058 Vs 16:05:02 Magnet Current for MAIN, Imag = 154.9677 A Vtrans = 1.549734 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:05:10 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893336 Vs 16:05:17 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887481 Vs 16:05:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893467 +- 0.000001997 Vs 16:05:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893467 +- 0.000001997 Vs BL = -0.05786934 +- 0.00003994 Tm Remeasure 16:05:17 Integrated Voltage Measurement... 16:05:18 Magnet Current for MAIN, Imag = 154.9686 A Vtrans = 1.549743 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:05:26 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902314 Vs 16:05:33 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002888133 Vs 16:05:34 Magnet Current for MAIN, Imag = 154.9689 A Vtrans = 1.549747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:05:41 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002901486 Vs 16:05:49 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002882364 Vs 16:05:50 Magnet Current for MAIN, Imag = 154.9683 A Vtrans = 1.549741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:05:57 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002903996 Vs 16:06:05 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885020 Vs 16:06:06 Magnet Current for MAIN, Imag = 154.9678 A Vtrans = 1.549736 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:06:13 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002898841 Vs 16:06:21 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887970 Vs 16:06:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893766 +- 0.000001245 Vs 16:06:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893766 +- 0.000001245 Vs BL = -0.05787531 +- 0.00002489 Tm Remeasure 16:06:21 Integrated Voltage Measurement... 16:06:22 Magnet Current for MAIN, Imag = 154.9689 A Vtrans = 1.549747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:06:29 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902412 Vs 16:06:37 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884759 Vs 16:06:37 Magnet Current for MAIN, Imag = 154.9682 A Vtrans = 1.549739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:06:45 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902025 Vs 16:06:53 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002895031 Vs 16:06:53 Magnet Current for MAIN, Imag = 154.9682 A Vtrans = 1.549739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:07:01 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002903391 Vs 16:07:09 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887271 Vs 16:07:09 Magnet Current for MAIN, Imag = 154.9682 A Vtrans = 1.549739 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:07:17 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902055 Vs 16:07:25 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885646 Vs 16:07:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002895324 +- 0.000001966 Vs 16:07:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002895324 +- 0.000001966 Vs BL = -0.05790648 +- 0.00003932 Tm Remeasure 16:07:25 Integrated Voltage Measurement... 16:07:25 Magnet Current for MAIN, Imag = 154.9683 A Vtrans = 1.549741 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:07:33 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002905274 Vs 16:07:40 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002891374 Vs 16:07:41 Magnet Current for MAIN, Imag = 154.9691 A Vtrans = 1.549748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:07:49 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002900233 Vs 16:07:56 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002890922 Vs 16:07:57 Magnet Current for MAIN, Imag = 154.9684 A Vtrans = 1.549742 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:08:05 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902829 Vs 16:08:12 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002891817 Vs 16:08:13 Magnet Current for MAIN, Imag = 154.9684 A Vtrans = 1.549742 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:08:20 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002896359 Vs 16:08:28 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887679 Vs 16:08:28 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002895811 +- 0.000002400 Vs 16:08:28 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002895811 +- 0.000002400 Vs BL = -0.05791622 +- 0.00004799 Tm Remeasure 16:08:28 Integrated Voltage Measurement... 16:08:29 Magnet Current for MAIN, Imag = 154.9692 A Vtrans = 1.549749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:08:36 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002897409 Vs 16:08:44 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002889531 Vs 16:08:45 Magnet Current for MAIN, Imag = 154.9692 A Vtrans = 1.549749 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:08:53 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002901660 Vs 16:09:00 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887197 Vs 16:09:01 Magnet Current for MAIN, Imag = 154.9688 A Vtrans = 1.549746 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:09:09 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902592 Vs 16:09:16 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002888233 Vs 16:09:17 Magnet Current for MAIN, Imag = 154.9689 A Vtrans = 1.549747 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:09:24 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002897787 Vs 16:09:32 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002892155 Vs 16:09:32 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002894570 +- 0.000000725 Vs 16:09:32 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002894570 +- 0.000000725 Vs BL = -0.05789141 +- 0.00001449 Tm 16:09:32 Integrated Voltage Measurement... 16:09:33 Magnet Current for MAIN, Imag = 154.9691 A Vtrans = 1.549748 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:09:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002820683 Vs 16:09:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809900 Vs 16:09:50 Magnet Current for MAIN, Imag = 154.9693 A Vtrans = 1.549751 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:09:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002821956 Vs 16:10:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807476 Vs 16:10:06 Magnet Current for MAIN, Imag = 154.9699 A Vtrans = 1.549757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:10:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002821720 Vs 16:10:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809908 Vs 16:10:22 Magnet Current for MAIN, Imag = 154.9694 A Vtrans = 1.549752 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:10:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002820901 Vs 16:10:37 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002806126 Vs 16:10:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002814834 +- 0.000000855 Vs 16:10:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002814834 +- 0.000000855 Vs BL = -0.05629668 +- 0.00001711 Tm Remeasure 16:10:37 Integrated Voltage Measurement... 16:10:38 Magnet Current for MAIN, Imag = 154.9697 A Vtrans = 1.549754 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:10:46 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002820457 Vs 16:10:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809715 Vs 16:10:54 Magnet Current for MAIN, Imag = 154.9702 A Vtrans = 1.549759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:11:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002819611 Vs 16:11:09 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002804725 Vs 16:11:10 Magnet Current for MAIN, Imag = 154.9699 A Vtrans = 1.549757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:11:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002825834 Vs 16:11:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809993 Vs 16:11:25 Magnet Current for MAIN, Imag = 154.9702 A Vtrans = 1.549759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:11:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815985 Vs 16:11:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002805207 Vs 16:11:41 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002813941 +- 0.000002803 Vs 16:11:41 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002813941 +- 0.000002803 Vs BL = -0.05627881 +- 0.00005606 Tm Remeasure 16:11:41 Integrated Voltage Measurement... 16:11:41 Magnet Current for MAIN, Imag = 154.9699 A Vtrans = 1.549757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:11:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815196 Vs 16:11:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807788 Vs 16:11:57 Magnet Current for MAIN, Imag = 154.9696 A Vtrans = 1.549753 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:12:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002822362 Vs 16:12:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002808119 Vs 16:12:13 Magnet Current for MAIN, Imag = 154.9701 A Vtrans = 1.549758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:12:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002817837 Vs 16:12:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002801430 Vs 16:12:29 Magnet Current for MAIN, Imag = 154.9704 A Vtrans = 1.549762 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:12:37 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002814298 Vs 16:12:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002806550 Vs 16:12:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002811698 +- 0.000002149 Vs 16:12:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002811698 +- 0.000002149 Vs BL = -0.05623395 +- 0.00004299 Tm Remeasure 16:12:45 Integrated Voltage Measurement... 16:12:45 Magnet Current for MAIN, Imag = 154.9699 A Vtrans = 1.549757 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:12:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002820479 Vs 16:13:00 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002810437 Vs 16:13:01 Magnet Current for MAIN, Imag = 154.9706 A Vtrans = 1.549763 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:13:09 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002814295 Vs 16:13:16 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002808140 Vs 16:13:17 Magnet Current for MAIN, Imag = 154.9702 A Vtrans = 1.549759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:13:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002824574 Vs 16:13:32 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002805261 Vs 16:13:33 Magnet Current for MAIN, Imag = 154.9702 A Vtrans = 1.549759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:13:40 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002816021 Vs 16:13:48 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809615 Vs 16:13:48 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002813603 +- 0.000001694 Vs 16:13:48 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002813603 +- 0.000001694 Vs BL = -0.05627205 +- 0.00003387 Tm 16:13:48 Integrated Voltage Measurement... 16:13:49 Magnet Current for MAIN, Imag = 154.9703 A Vtrans = 1.549761 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:13:57 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663271 Vs 16:14:05 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002655123 Vs 16:14:06 Magnet Current for MAIN, Imag = 154.9701 A Vtrans = 1.549758 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:14:13 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664896 Vs 16:14:21 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647939 Vs 16:14:22 Magnet Current for MAIN, Imag = 154.9707 A Vtrans = 1.549764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:14:29 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002659893 Vs 16:14:37 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002651275 Vs 16:14:38 Magnet Current for MAIN, Imag = 154.9709 A Vtrans = 1.549767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:14:45 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664816 Vs 16:14:53 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648936 Vs 16:14:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657019 +- 0.000001340 Vs 16:14:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657019 +- 0.000001340 Vs BL = -0.05314037 +- 0.00002680 Tm Remeasure 16:14:53 Integrated Voltage Measurement... 16:14:54 Magnet Current for MAIN, Imag = 154.9713 A Vtrans = 1.549771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:15:01 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002662159 Vs 16:15:09 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002650064 Vs 16:15:09 Magnet Current for MAIN, Imag = 154.9712 A Vtrans = 1.549769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:15:17 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002666427 Vs 16:15:25 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648766 Vs 16:15:25 Magnet Current for MAIN, Imag = 154.9709 A Vtrans = 1.549767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:15:33 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002670772 Vs 16:15:41 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648740 Vs 16:15:41 Magnet Current for MAIN, Imag = 154.9714 A Vtrans = 1.549772 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:15:49 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002667288 Vs 16:15:56 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647940 Vs 16:15:56 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657769 +- 0.000001299 Vs 16:15:56 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657769 +- 0.000001299 Vs BL = -0.05315539 +- 0.00002598 Tm Remeasure 16:15:56 Integrated Voltage Measurement... 16:15:57 Magnet Current for MAIN, Imag = 154.9707 A Vtrans = 1.549764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:16:05 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002672063 Vs 16:16:12 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002646878 Vs 16:16:13 Magnet Current for MAIN, Imag = 154.9707 A Vtrans = 1.549764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:16:21 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002661947 Vs 16:16:28 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645447 Vs 16:16:29 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:16:37 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002671358 Vs 16:16:44 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647002 Vs 16:16:45 Magnet Current for MAIN, Imag = 154.9714 A Vtrans = 1.549772 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:16:53 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002666504 Vs 16:17:00 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649334 Vs 16:17:00 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657567 +- 0.000002309 Vs 16:17:00 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657567 +- 0.000002309 Vs BL = -0.05315133 +- 0.00004618 Tm Remeasure 16:17:00 Integrated Voltage Measurement... 16:17:01 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:17:09 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664463 Vs 16:17:16 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002652431 Vs 16:17:17 Magnet Current for MAIN, Imag = 154.9702 A Vtrans = 1.549759 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:17:25 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663826 Vs 16:17:32 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649341 Vs 16:17:33 Magnet Current for MAIN, Imag = 154.9711 A Vtrans = 1.549768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:17:41 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664065 Vs 16:17:48 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645157 Vs 16:17:49 Magnet Current for MAIN, Imag = 154.9716 A Vtrans = 1.549773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:17:57 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002656160 Vs 16:18:04 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002646511 Vs 16:18:04 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002655244 +- 0.000002633 Vs 16:18:04 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002655244 +- 0.000002633 Vs BL = -0.05310489 +- 0.00005266 Tm Remeasure 16:18:04 Integrated Voltage Measurement... 16:18:05 Magnet Current for MAIN, Imag = 154.9711 A Vtrans = 1.549768 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:18:13 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664372 Vs 16:18:20 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002653145 Vs 16:18:21 Magnet Current for MAIN, Imag = 154.9707 A Vtrans = 1.549764 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:18:29 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002668005 Vs 16:18:36 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002652378 Vs 16:18:37 Magnet Current for MAIN, Imag = 154.9709 A Vtrans = 1.549767 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:18:45 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002661938 Vs 16:18:52 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002654834 Vs 16:18:53 Magnet Current for MAIN, Imag = 154.9708 A Vtrans = 1.549766 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:19:01 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002661866 Vs 16:19:08 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002644972 Vs 16:19:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657689 +- 0.000002556 Vs 16:19:08 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657689 +- 0.000002556 Vs BL = -0.05315377 +- 0.00005112 Tm 16:19:12 Position moved: 0.000000 m 16:19:12 Magnet system MAIN current ramping to 155.0000 A... 16:19:23 Magnet Current for MAIN, Imag = 154.9712 A Vtrans = 1.549769 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:19:24 MAIN (V) Voltage Measurement, V = 6.145942 V 16:19:27 Temperature Measurement, Probe Number = 0, T = 26.819000 C 16:19:28 Temperature Measurement, Probe Number = 1, T = 28.602000 C 16:19:28 Temperature Measurement, Probe Number = 2, T = 29.140000 C 16:19:29 Temperature Measurement, Probe Number = 3, T = 28.962000 C 16:19:30 Temperature Measurement, Probe Number = 4, T = 30.826000 C 16:19:30 Temperature Measurement, Probe Number = 5, T = 26.264000 C 16:19:31 Sensor Voltage Measurement, Sensor Number = 0, V = 2.658585 V 16:19:31 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.658585 (V, A, ohm, ...), Measured Value = 124.393868 (C, atm, Hz, ...) 16:19:31 Sensor Voltage Measurement, Sensor Number = 1, V = 1.158932 V 16:19:31 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.158932 (V, A, ohm, ...), Measured Value = 11.919923 (C, atm, Hz, ...) 16:19:31 Magnet Test Parameter Measurements P0 = MAIN, Value = 154.97 P1 = MAIN (V), Value = 6.15 P2 = Yoke, Value = 26.82 P3 = Bottom Coil, Value = 28.60 P4 = Top Coil, Value = 29.14 P5 = Water In, Value = 28.96 P6 = Water Out, Value = 30.83 P7 = Ambient, Value = 26.26 P8 = Supply Pres(psi), Value = 124.39 P9 = Return Pres(psi), Value = 11.92 16:19:31 Integrated Voltage Measurement... 16:19:32 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:19:41 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651315 Vs 16:19:48 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636001 Vs 16:19:49 Magnet Current for MAIN, Imag = 154.9719 A Vtrans = 1.549777 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:19:57 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002658219 Vs 16:20:04 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002646901 Vs 16:20:05 Magnet Current for MAIN, Imag = 154.9716 A Vtrans = 1.549773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:20:13 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002650947 Vs 16:20:20 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639162 Vs 16:20:21 Magnet Current for MAIN, Imag = 154.9718 A Vtrans = 1.549776 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:20:29 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657196 Vs 16:20:36 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002638671 Vs 16:20:36 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002647302 +- 0.000003405 Vs 16:20:36 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002647302 +- 0.000003405 Vs BL = -0.05294603 +- 0.00006810 Tm Remeasure 16:20:36 Integrated Voltage Measurement... 16:20:37 Magnet Current for MAIN, Imag = 154.9721 A Vtrans = 1.549778 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:20:44 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659647 Vs 16:20:52 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002637906 Vs 16:20:53 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:21:00 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659695 Vs 16:21:08 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640381 Vs 16:21:09 Magnet Current for MAIN, Imag = 154.9713 A Vtrans = 1.549771 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:21:16 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657528 Vs 16:21:24 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640284 Vs 16:21:25 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:21:32 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655509 Vs 16:21:40 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002637960 Vs 16:21:40 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002648614 +- 0.000001191 Vs 16:21:40 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002648614 +- 0.000001191 Vs BL = -0.05297227 +- 0.00002382 Tm Remeasure 16:21:40 Integrated Voltage Measurement... 16:21:41 Magnet Current for MAIN, Imag = 154.9719 A Vtrans = 1.549777 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:21:48 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657354 Vs 16:21:56 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002647500 Vs 16:21:57 Magnet Current for MAIN, Imag = 154.9717 A Vtrans = 1.549774 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:22:04 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654933 Vs 16:22:12 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002645746 Vs 16:22:13 Magnet Current for MAIN, Imag = 154.9722 A Vtrans = 1.549779 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:22:20 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002661074 Vs 16:22:28 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640916 Vs 16:22:29 Magnet Current for MAIN, Imag = 154.9727 A Vtrans = 1.549784 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:22:36 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659134 Vs 16:22:44 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640775 Vs 16:22:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002650929 +- 0.000000942 Vs 16:22:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002650929 +- 0.000000942 Vs BL = -0.05301858 +- 0.00001883 Tm Remeasure 16:22:44 Integrated Voltage Measurement... 16:22:45 Magnet Current for MAIN, Imag = 154.9716 A Vtrans = 1.549773 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:22:52 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659348 Vs 16:23:00 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002637703 Vs 16:23:01 Magnet Current for MAIN, Imag = 154.9721 A Vtrans = 1.549778 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:23:08 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002659270 Vs 16:23:16 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002645848 Vs 16:23:17 Magnet Current for MAIN, Imag = 154.9724 A Vtrans = 1.549782 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:23:24 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654060 Vs 16:23:32 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002635440 Vs 16:23:32 Magnet Current for MAIN, Imag = 154.9724 A Vtrans = 1.549782 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:23:40 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655825 Vs 16:23:48 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002643444 Vs 16:23:48 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002648867 +- 0.000002797 Vs 16:23:48 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002648867 +- 0.000002797 Vs BL = -0.05297734 +- 0.00005593 Tm Remeasure 16:23:48 Integrated Voltage Measurement... 16:23:48 Magnet Current for MAIN, Imag = 154.9727 A Vtrans = 1.549784 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:23:56 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002660163 Vs 16:24:04 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636536 Vs 16:24:04 Magnet Current for MAIN, Imag = 154.9733 A Vtrans = 1.549791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:24:12 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654434 Vs 16:24:20 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002646224 Vs 16:24:20 Magnet Current for MAIN, Imag = 154.9733 A Vtrans = 1.549791 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:24:28 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002653148 Vs 16:24:36 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002645105 Vs 16:24:36 Magnet Current for MAIN, Imag = 154.9727 A Vtrans = 1.549784 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:24:44 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651316 Vs 16:24:52 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002648177 Vs 16:24:52 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002649388 +- 0.000000735 Vs 16:24:52 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002649388 +- 0.000000735 Vs BL = -0.05298776 +- 0.00001470 Tm 16:24:52 Integrated Voltage Measurement... 16:24:53 Magnet Current for MAIN, Imag = 154.9729 A Vtrans = 1.549787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:25:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002826553 Vs 16:25:09 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002800516 Vs 16:25:10 Magnet Current for MAIN, Imag = 154.9728 A Vtrans = 1.549786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:25:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002819740 Vs 16:25:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002804362 Vs 16:25:25 Magnet Current for MAIN, Imag = 154.9734 A Vtrans = 1.549792 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:25:33 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002817986 Vs 16:25:41 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002805043 Vs 16:25:42 Magnet Current for MAIN, Imag = 154.9726 A Vtrans = 1.549783 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:25:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002816534 Vs 16:25:57 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002797514 Vs 16:25:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002811031 +- 0.000002429 Vs 16:25:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002811031 +- 0.000002429 Vs BL = -0.05622062 +- 0.00004858 Tm Remeasure 16:25:57 Integrated Voltage Measurement... 16:25:58 Magnet Current for MAIN, Imag = 154.9731 A Vtrans = 1.549788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:26:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002817475 Vs 16:26:13 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803218 Vs 16:26:13 Magnet Current for MAIN, Imag = 154.9728 A Vtrans = 1.549786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:26:21 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002812154 Vs 16:26:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002802869 Vs 16:26:29 Magnet Current for MAIN, Imag = 154.9736 A Vtrans = 1.549793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:26:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002818332 Vs 16:26:44 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002804800 Vs 16:26:45 Magnet Current for MAIN, Imag = 154.9731 A Vtrans = 1.549788 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:26:53 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002819284 Vs 16:27:00 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002808039 Vs 16:27:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002810771 +- 0.000002224 Vs 16:27:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002810771 +- 0.000002224 Vs BL = -0.05621543 +- 0.00004449 Tm Remeasure 16:27:00 Integrated Voltage Measurement... 16:27:01 Magnet Current for MAIN, Imag = 154.9728 A Vtrans = 1.549786 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:27:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002819148 Vs 16:27:16 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801194 Vs 16:27:17 Magnet Current for MAIN, Imag = 154.9729 A Vtrans = 1.549787 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:27:25 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002817203 Vs 16:27:32 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801450 Vs 16:27:33 Magnet Current for MAIN, Imag = 154.9736 A Vtrans = 1.549793 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:27:40 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002819487 Vs 16:27:48 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002800522 Vs 16:27:49 Magnet Current for MAIN, Imag = 154.9739 A Vtrans = 1.549797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:27:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002818450 Vs 16:28:04 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803681 Vs 16:28:04 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002810142 +- 0.000000620 Vs 16:28:04 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002810142 +- 0.000000620 Vs BL = -0.05620284 +- 0.00001240 Tm 16:28:04 Integrated Voltage Measurement... 16:28:05 Magnet Current for MAIN, Imag = 154.9739 A Vtrans = 1.549797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:28:13 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002895323 Vs 16:28:21 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002883409 Vs 16:28:22 Magnet Current for MAIN, Imag = 154.9734 A Vtrans = 1.549792 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:28:29 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896643 Vs 16:28:37 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002889840 Vs 16:28:38 Magnet Current for MAIN, Imag = 154.9737 A Vtrans = 1.549794 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:28:45 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896800 Vs 16:28:53 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886704 Vs 16:28:53 Magnet Current for MAIN, Imag = 154.9739 A Vtrans = 1.549797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:29:01 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002902303 Vs 16:29:09 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885496 Vs 16:29:09 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002892065 +- 0.000001741 Vs 16:29:09 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002892065 +- 0.000001741 Vs BL = -0.05784129 +- 0.00003483 Tm Remeasure 16:29:09 Integrated Voltage Measurement... 16:29:09 Magnet Current for MAIN, Imag = 154.9741 A Vtrans = 1.549798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:29:17 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002899434 Vs 16:29:24 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886092 Vs 16:29:25 Magnet Current for MAIN, Imag = 154.9741 A Vtrans = 1.549798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:29:33 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002901599 Vs 16:29:41 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002883711 Vs 16:29:41 Magnet Current for MAIN, Imag = 154.9739 A Vtrans = 1.549797 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:29:49 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002904124 Vs 16:29:57 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002882213 Vs 16:29:57 Magnet Current for MAIN, Imag = 154.9741 A Vtrans = 1.549798 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:30:05 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002901686 Vs 16:30:12 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885031 Vs 16:30:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002892986 +- 0.000000288 Vs 16:30:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002892986 +- 0.000000288 Vs BL = -0.05785973 +- 0.00000576 Tm 16:30:12 Integrated Voltage Measurement... 16:30:13 Magnet Current for MAIN, Imag = 154.9746 A Vtrans = 1.549803 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:30:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937457 Vs 16:30:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919794 Vs 16:30:30 Magnet Current for MAIN, Imag = 154.9743 A Vtrans = 1.549800 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:30:38 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939998 Vs 16:30:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002921634 Vs 16:30:46 Magnet Current for MAIN, Imag = 154.9749 A Vtrans = 1.549807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:30:54 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002934587 Vs 16:31:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924209 Vs 16:31:02 Magnet Current for MAIN, Imag = 154.9747 A Vtrans = 1.549804 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:31:10 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002944231 Vs 16:31:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919182 Vs 16:31:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002930137 +- 0.000001200 Vs 16:31:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002930137 +- 0.000001200 Vs BL = -0.05860273 +- 0.00002399 Tm Remeasure 16:31:18 Integrated Voltage Measurement... 16:31:18 Magnet Current for MAIN, Imag = 154.9749 A Vtrans = 1.549807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:31:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002952052 Vs 16:31:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924564 Vs 16:31:34 Magnet Current for MAIN, Imag = 154.9752 A Vtrans = 1.549809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:31:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002948775 Vs 16:31:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002930105 Vs 16:31:50 Magnet Current for MAIN, Imag = 154.9748 A Vtrans = 1.549805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:31:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002951248 Vs 16:32:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002927554 Vs 16:32:06 Magnet Current for MAIN, Imag = 154.9748 A Vtrans = 1.549805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:32:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002943950 Vs 16:32:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002921289 Vs 16:32:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937442 +- 0.000002821 Vs 16:32:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002937442 +- 0.000002821 Vs BL = -0.05874884 +- 0.00005642 Tm Remeasure 16:32:21 Integrated Voltage Measurement... 16:32:22 Magnet Current for MAIN, Imag = 154.9748 A Vtrans = 1.549805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:32:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002940843 Vs 16:32:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002920234 Vs 16:32:38 Magnet Current for MAIN, Imag = 154.9749 A Vtrans = 1.549807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:32:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002942845 Vs 16:32:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923944 Vs 16:32:54 Magnet Current for MAIN, Imag = 154.9751 A Vtrans = 1.549808 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:33:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002936637 Vs 16:33:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923715 Vs 16:33:10 Magnet Current for MAIN, Imag = 154.9752 A Vtrans = 1.549809 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:33:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002925012 Vs 16:33:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923401 Vs 16:33:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002929579 +- 0.000003343 Vs 16:33:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002929579 +- 0.000003343 Vs BL = -0.05859158 +- 0.00006686 Tm Remeasure 16:33:25 Integrated Voltage Measurement... 16:33:25 Magnet Current for MAIN, Imag = 154.9756 A Vtrans = 1.549813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:33:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002938495 Vs 16:33:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924962 Vs 16:33:41 Magnet Current for MAIN, Imag = 154.9748 A Vtrans = 1.549805 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:33:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935159 Vs 16:33:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002925009 Vs 16:33:57 Magnet Current for MAIN, Imag = 154.9753 A Vtrans = 1.549810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:34:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002949065 Vs 16:34:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002923549 Vs 16:34:13 Magnet Current for MAIN, Imag = 154.9753 A Vtrans = 1.549810 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:34:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002942401 Vs 16:34:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002920846 Vs 16:34:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002932436 +- 0.000002328 Vs 16:34:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932436 +- 0.000002328 Vs BL = -0.05864871 +- 0.00004656 Tm Remeasure 16:34:29 Integrated Voltage Measurement... 16:34:30 Magnet Current for MAIN, Imag = 154.9749 A Vtrans = 1.549807 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:34:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002930413 Vs 16:34:44 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922777 Vs 16:34:45 Magnet Current for MAIN, Imag = 154.9754 A Vtrans = 1.549812 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:34:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002938940 Vs 16:35:00 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002920369 Vs 16:35:01 Magnet Current for MAIN, Imag = 154.9758 A Vtrans = 1.549816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:35:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935423 Vs 16:35:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922904 Vs 16:35:17 Magnet Current for MAIN, Imag = 154.9763 A Vtrans = 1.549821 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:35:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939868 Vs 16:35:32 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922404 Vs 16:35:32 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002929137 +- 0.000001637 Vs 16:35:32 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002929137 +- 0.000001637 Vs BL = -0.05858274 +- 0.00003275 Tm 16:35:32 Integrated Voltage Measurement... 16:35:33 Magnet Current for MAIN, Imag = 154.9759 A Vtrans = 1.549817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:35:42 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002950789 Vs 16:35:49 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002941005 Vs 16:35:50 Magnet Current for MAIN, Imag = 154.9756 A Vtrans = 1.549813 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:35:58 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953306 Vs 16:36:05 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002960059 Vs 16:36:06 Magnet Current for MAIN, Imag = 154.9758 A Vtrans = 1.549816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:36:13 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957914 Vs 16:36:21 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002940784 Vs 16:36:22 Magnet Current for MAIN, Imag = 154.9757 A Vtrans = 1.549814 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:36:29 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955718 Vs 16:36:37 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002946407 Vs 16:36:37 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002950748 +- 0.000003899 Vs 16:36:37 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950748 +- 0.000003899 Vs BL = -0.05901496 +- 0.00007798 Tm Remeasure 16:36:37 Integrated Voltage Measurement... 16:36:37 Magnet Current for MAIN, Imag = 154.9758 A Vtrans = 1.549816 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:36:45 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956730 Vs 16:36:53 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002957273 Vs 16:36:53 Magnet Current for MAIN, Imag = 154.9761 A Vtrans = 1.549818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:37:01 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002961168 Vs 16:37:09 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944766 Vs 16:37:10 Magnet Current for MAIN, Imag = 154.9759 A Vtrans = 1.549817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:37:17 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953781 Vs 16:37:25 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002920513 Vs 16:37:26 Magnet Current for MAIN, Imag = 154.9761 A Vtrans = 1.549818 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:37:33 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956173 Vs 16:37:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944836 Vs 16:37:41 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002949405 +- 0.000007447 Vs 16:37:41 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002949405 +- 0.000007447 Vs BL = -0.05898811 +- 0.00014895 Tm Remeasure 16:37:41 Integrated Voltage Measurement... 16:37:42 Magnet Current for MAIN, Imag = 154.9759 A Vtrans = 1.549817 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:37:49 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954706 Vs 16:37:57 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002936570 Vs 16:37:58 Magnet Current for MAIN, Imag = 154.9767 A Vtrans = 1.549824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:38:05 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953929 Vs 16:38:13 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002937313 Vs 16:38:14 Magnet Current for MAIN, Imag = 154.9764 A Vtrans = 1.549822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:38:21 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002958169 Vs 16:38:29 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002934678 Vs 16:38:30 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:38:37 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956700 Vs 16:38:45 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938370 Vs 16:38:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002946304 +- 0.000000781 Vs 16:38:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946304 +- 0.000000781 Vs BL = -0.05892609 +- 0.00001562 Tm Remeasure 16:38:45 Integrated Voltage Measurement... 16:38:46 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:38:53 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957730 Vs 16:39:01 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002935638 Vs 16:39:02 Magnet Current for MAIN, Imag = 154.9766 A Vtrans = 1.549823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:39:09 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955177 Vs 16:39:17 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002934193 Vs 16:39:18 Magnet Current for MAIN, Imag = 154.9763 A Vtrans = 1.549821 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:39:25 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957634 Vs 16:39:33 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002942362 Vs 16:39:34 Magnet Current for MAIN, Imag = 154.9766 A Vtrans = 1.549823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:39:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002952375 Vs 16:39:49 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002932789 Vs 16:39:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002945987 +- 0.000002732 Vs 16:39:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002945987 +- 0.000002732 Vs BL = -0.05891974 +- 0.00005465 Tm 16:39:49 Integrated Voltage Measurement... 16:39:50 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:39:59 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002956982 Vs 16:40:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943475 Vs 16:40:07 Magnet Current for MAIN, Imag = 154.9764 A Vtrans = 1.549822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:40:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957785 Vs 16:40:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002941470 Vs 16:40:23 Magnet Current for MAIN, Imag = 154.9764 A Vtrans = 1.549822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:40:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959198 Vs 16:40:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944153 Vs 16:40:39 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:40:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002964041 Vs 16:40:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945735 Vs 16:40:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002951605 +- 0.000002036 Vs 16:40:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951605 +- 0.000002036 Vs BL = -0.05903209 +- 0.00004073 Tm Remeasure 16:40:54 Integrated Voltage Measurement... 16:40:55 Magnet Current for MAIN, Imag = 154.9767 A Vtrans = 1.549824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:41:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002961010 Vs 16:41:10 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944259 Vs 16:41:11 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:41:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002961701 Vs 16:41:26 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002946179 Vs 16:41:27 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:41:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959304 Vs 16:41:42 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002946060 Vs 16:41:43 Magnet Current for MAIN, Imag = 154.9767 A Vtrans = 1.549824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:41:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957993 Vs 16:41:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002947115 Vs 16:41:58 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002952953 +- 0.000000572 Vs 16:41:58 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952953 +- 0.000000572 Vs BL = -0.05905905 +- 0.00001144 Tm 16:41:58 Integrated Voltage Measurement... 16:41:59 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:42:07 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002960372 Vs 16:42:15 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946518 Vs 16:42:16 Magnet Current for MAIN, Imag = 154.9766 A Vtrans = 1.549823 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:42:23 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959177 Vs 16:42:31 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002944256 Vs 16:42:32 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:42:39 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002956717 Vs 16:42:47 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002943922 Vs 16:42:47 Magnet Current for MAIN, Imag = 154.9778 A Vtrans = 1.549835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:42:55 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002956970 Vs 16:43:03 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946150 Vs 16:43:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002951760 +- 0.000001113 Vs 16:43:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951760 +- 0.000001113 Vs BL = -0.05903521 +- 0.00002226 Tm Remeasure 16:43:03 Integrated Voltage Measurement... 16:43:03 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:43:11 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002956341 Vs 16:43:18 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947367 Vs 16:43:19 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:43:27 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002955456 Vs 16:43:34 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947871 Vs 16:43:35 Magnet Current for MAIN, Imag = 154.9776 A Vtrans = 1.549833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:43:43 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002956426 Vs 16:43:50 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948073 Vs 16:43:51 Magnet Current for MAIN, Imag = 154.9771 A Vtrans = 1.549828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:43:59 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002960117 Vs 16:44:06 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946577 Vs 16:44:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952279 +- 0.000000652 Vs 16:44:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952279 +- 0.000000652 Vs BL = -0.05904557 +- 0.00001304 Tm 16:44:06 Integrated Voltage Measurement... 16:44:07 Magnet Current for MAIN, Imag = 154.9767 A Vtrans = 1.549824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:44:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960605 Vs 16:44:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002949349 Vs 16:44:24 Magnet Current for MAIN, Imag = 154.9771 A Vtrans = 1.549828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:44:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960077 Vs 16:44:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002946256 Vs 16:44:40 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:44:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002958523 Vs 16:44:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002943077 Vs 16:44:56 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:45:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959598 Vs 16:45:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002948519 Vs 16:45:11 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953251 +- 0.000001553 Vs 16:45:11 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953251 +- 0.000001553 Vs BL = -0.05906501 +- 0.00003106 Tm Remeasure 16:45:11 Integrated Voltage Measurement... 16:45:12 Magnet Current for MAIN, Imag = 154.9771 A Vtrans = 1.549828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:45:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002963101 Vs 16:45:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002945015 Vs 16:45:27 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:45:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002962245 Vs 16:45:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947150 Vs 16:45:43 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:45:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959314 Vs 16:45:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002942134 Vs 16:45:59 Magnet Current for MAIN, Imag = 154.9771 A Vtrans = 1.549828 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:46:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953802 Vs 16:46:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002943355 Vs 16:46:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002952015 +- 0.000002492 Vs 16:46:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952015 +- 0.000002492 Vs BL = -0.05904029 +- 0.00004985 Tm Remeasure 16:46:14 Integrated Voltage Measurement... 16:46:15 Magnet Current for MAIN, Imag = 154.9772 A Vtrans = 1.549829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:46:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959111 Vs 16:46:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002949238 Vs 16:46:31 Magnet Current for MAIN, Imag = 154.9769 A Vtrans = 1.549827 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:46:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960942 Vs 16:46:46 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944898 Vs 16:46:47 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:46:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960571 Vs 16:47:02 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944817 Vs 16:47:02 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:47:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002965101 Vs 16:47:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002943477 Vs 16:47:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953519 +- 0.000000718 Vs 16:47:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953519 +- 0.000000718 Vs BL = -0.05907038 +- 0.00001436 Tm 16:47:18 Integrated Voltage Measurement... 16:47:18 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:47:27 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002966363 Vs 16:47:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945044 Vs 16:47:35 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:47:43 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960177 Vs 16:47:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002944869 Vs 16:47:51 Magnet Current for MAIN, Imag = 154.9768 A Vtrans = 1.549826 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:47:59 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959176 Vs 16:48:07 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002941086 Vs 16:48:07 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:48:15 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958824 Vs 16:48:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002940666 Vs 16:48:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002952025 +- 0.000002375 Vs 16:48:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952025 +- 0.000002375 Vs BL = -0.05904051 +- 0.00004750 Tm Remeasure 16:48:22 Integrated Voltage Measurement... 16:48:23 Magnet Current for MAIN, Imag = 154.9772 A Vtrans = 1.549829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:48:31 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959270 Vs 16:48:39 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002941639 Vs 16:48:39 Magnet Current for MAIN, Imag = 154.9772 A Vtrans = 1.549829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:48:47 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959924 Vs 16:48:55 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945014 Vs 16:48:55 Magnet Current for MAIN, Imag = 154.9764 A Vtrans = 1.549822 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:49:03 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957792 Vs 16:49:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945770 Vs 16:49:11 Magnet Current for MAIN, Imag = 154.9767 A Vtrans = 1.549824 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:49:19 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959341 Vs 16:49:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947227 Vs 16:49:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002951997 +- 0.000001037 Vs 16:49:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951997 +- 0.000001037 Vs BL = -0.05903994 +- 0.00002075 Tm Remeasure 16:49:26 Integrated Voltage Measurement... 16:49:27 Magnet Current for MAIN, Imag = 154.9773 A Vtrans = 1.549831 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:49:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002966021 Vs 16:49:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002942206 Vs 16:49:43 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:49:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958645 Vs 16:49:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002939998 Vs 16:49:59 Magnet Current for MAIN, Imag = 154.9776 A Vtrans = 1.549833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:50:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002963828 Vs 16:50:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945134 Vs 16:50:15 Magnet Current for MAIN, Imag = 154.9777 A Vtrans = 1.549834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:50:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002963273 Vs 16:50:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945559 Vs 16:50:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953083 +- 0.000002176 Vs 16:50:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953083 +- 0.000002176 Vs BL = -0.05906166 +- 0.00004352 Tm Remeasure 16:50:30 Integrated Voltage Measurement... 16:50:31 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:50:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962991 Vs 16:50:46 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002943578 Vs 16:50:46 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:50:54 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002956452 Vs 16:51:02 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945633 Vs 16:51:03 Magnet Current for MAIN, Imag = 154.9777 A Vtrans = 1.549834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:51:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957888 Vs 16:51:18 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002950359 Vs 16:51:18 Magnet Current for MAIN, Imag = 154.9778 A Vtrans = 1.549835 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:51:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957540 Vs 16:51:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002943137 Vs 16:51:34 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002952197 +- 0.000001556 Vs 16:51:34 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952197 +- 0.000001556 Vs BL = -0.05904394 +- 0.00003111 Tm Remeasure 16:51:34 Integrated Voltage Measurement... 16:51:35 Magnet Current for MAIN, Imag = 154.9776 A Vtrans = 1.549833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:51:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002955514 Vs 16:51:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002949878 Vs 16:51:51 Magnet Current for MAIN, Imag = 154.9774 A Vtrans = 1.549832 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:51:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961765 Vs 16:52:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002943007 Vs 16:52:07 Magnet Current for MAIN, Imag = 154.9772 A Vtrans = 1.549829 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:52:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960306 Vs 16:52:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002948181 Vs 16:52:22 Magnet Current for MAIN, Imag = 154.9776 A Vtrans = 1.549833 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:52:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958854 Vs 16:52:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002941863 Vs 16:52:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002952421 +- 0.000001383 Vs 16:52:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952421 +- 0.000001383 Vs BL = -0.05904842 +- 0.00002766 Tm 16:52:38 Integrated Voltage Measurement... 16:52:38 Magnet Current for MAIN, Imag = 154.9777 A Vtrans = 1.549834 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:52:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002958500 Vs 16:52:55 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942168 Vs 16:52:55 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:53:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002957964 Vs 16:53:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942941 Vs 16:53:11 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:53:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002956734 Vs 16:53:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002945312 Vs 16:53:27 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:53:35 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002958820 Vs 16:53:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943585 Vs 16:53:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002950753 +- 0.000000368 Vs 16:53:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950753 +- 0.000000368 Vs BL = -0.05901506 +- 0.00000735 Tm 16:53:42 Integrated Voltage Measurement... 16:53:43 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:53:52 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002955375 Vs 16:53:59 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002936622 Vs 16:54:00 Magnet Current for MAIN, Imag = 154.9779 A Vtrans = 1.549837 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:54:08 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002956510 Vs 16:54:15 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002940339 Vs 16:54:16 Magnet Current for MAIN, Imag = 154.9784 A Vtrans = 1.549842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:54:24 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002948411 Vs 16:54:31 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002937299 Vs 16:54:32 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:54:40 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002958936 Vs 16:54:47 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002934577 Vs 16:54:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002946009 +- 0.000002021 Vs 16:54:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946009 +- 0.000002021 Vs BL = -0.05892017 +- 0.00004042 Tm Remeasure 16:54:47 Integrated Voltage Measurement... 16:54:48 Magnet Current for MAIN, Imag = 154.9781 A Vtrans = 1.549838 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:54:56 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002959905 Vs 16:55:03 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938241 Vs 16:55:04 Magnet Current for MAIN, Imag = 154.9784 A Vtrans = 1.549842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:55:12 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954438 Vs 16:55:19 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002936640 Vs 16:55:20 Magnet Current for MAIN, Imag = 154.9786 A Vtrans = 1.549843 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:55:27 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951708 Vs 16:55:35 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002941987 Vs 16:55:36 Magnet Current for MAIN, Imag = 154.9784 A Vtrans = 1.549842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:55:43 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953358 Vs 16:55:51 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002941257 Vs 16:55:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002947192 +- 0.000001265 Vs 16:55:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947192 +- 0.000001265 Vs BL = -0.05894384 +- 0.00002530 Tm Remeasure 16:55:51 Integrated Voltage Measurement... 16:55:52 Magnet Current for MAIN, Imag = 154.9783 A Vtrans = 1.549840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:55:59 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002952565 Vs 16:56:07 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002937952 Vs 16:56:08 Magnet Current for MAIN, Imag = 154.9788 A Vtrans = 1.549845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:56:15 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951621 Vs 16:56:23 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002939439 Vs 16:56:23 Magnet Current for MAIN, Imag = 154.9784 A Vtrans = 1.549842 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:56:31 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951744 Vs 16:56:39 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002935189 Vs 16:56:39 Magnet Current for MAIN, Imag = 154.9783 A Vtrans = 1.549840 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:56:47 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953809 Vs 16:56:55 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002933969 Vs 16:56:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002944536 +- 0.000000876 Vs 16:56:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002944536 +- 0.000000876 Vs BL = -0.05889072 +- 0.00001753 Tm 16:56:55 Integrated Voltage Measurement... 16:56:55 Magnet Current for MAIN, Imag = 154.9789 A Vtrans = 1.549847 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:57:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940511 Vs 16:57:12 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002932617 Vs 16:57:12 Magnet Current for MAIN, Imag = 154.9787 A Vtrans = 1.549844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:57:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002943295 Vs 16:57:28 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923812 Vs 16:57:28 Magnet Current for MAIN, Imag = 154.9787 A Vtrans = 1.549844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:57:36 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939843 Vs 16:57:44 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924342 Vs 16:57:44 Magnet Current for MAIN, Imag = 154.9792 A Vtrans = 1.549849 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:57:52 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940380 Vs 16:57:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002922960 Vs 16:57:59 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002933470 +- 0.000001918 Vs 16:57:59 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002933470 +- 0.000001918 Vs BL = -0.05866940 +- 0.00003837 Tm Remeasure 16:57:59 Integrated Voltage Measurement... 16:58:00 Magnet Current for MAIN, Imag = 154.9791 A Vtrans = 1.549848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:58:08 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938606 Vs 16:58:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924840 Vs 16:58:16 Magnet Current for MAIN, Imag = 154.9788 A Vtrans = 1.549845 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:58:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002947396 Vs 16:58:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002925471 Vs 16:58:32 Magnet Current for MAIN, Imag = 154.9787 A Vtrans = 1.549844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:58:40 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002937478 Vs 16:58:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924220 Vs 16:58:48 Magnet Current for MAIN, Imag = 154.9789 A Vtrans = 1.549847 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:58:56 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002937898 Vs 16:59:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923962 Vs 16:59:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002932484 +- 0.000002306 Vs 16:59:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932484 +- 0.000002306 Vs BL = -0.05864968 +- 0.00004612 Tm Remeasure 16:59:03 Integrated Voltage Measurement... 16:59:04 Magnet Current for MAIN, Imag = 154.9791 A Vtrans = 1.549848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:59:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002941065 Vs 16:59:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924349 Vs 16:59:20 Magnet Current for MAIN, Imag = 154.9787 A Vtrans = 1.549844 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:59:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002942151 Vs 16:59:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002919708 Vs 16:59:36 Magnet Current for MAIN, Imag = 154.9789 A Vtrans = 1.549847 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:59:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940704 Vs 16:59:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002926238 Vs 16:59:51 Magnet Current for MAIN, Imag = 154.9791 A Vtrans = 1.549848 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 16:59:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939801 Vs 17:00:07 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002931012 Vs 17:00:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002933128 +- 0.000001606 Vs 17:00:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002933128 +- 0.000001606 Vs BL = -0.05866257 +- 0.00003213 Tm Remeasure 17:00:07 Integrated Voltage Measurement... 17:00:07 Magnet Current for MAIN, Imag = 154.9792 A Vtrans = 1.549849 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:00:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936956 Vs 17:00:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002928363 Vs 17:00:23 Magnet Current for MAIN, Imag = 154.9796 A Vtrans = 1.549853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:00:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002932771 Vs 17:00:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002921939 Vs 17:00:39 Magnet Current for MAIN, Imag = 154.9792 A Vtrans = 1.549849 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:00:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002942353 Vs 17:00:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002929079 Vs 17:00:55 Magnet Current for MAIN, Imag = 154.9796 A Vtrans = 1.549853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:01:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938807 Vs 17:01:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002928564 Vs 17:01:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002932354 +- 0.000003089 Vs 17:01:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932354 +- 0.000003089 Vs BL = -0.05864708 +- 0.00006177 Tm Remeasure 17:01:10 Integrated Voltage Measurement... 17:01:10 Magnet Current for MAIN, Imag = 154.9796 A Vtrans = 1.549853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:01:18 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936139 Vs 17:01:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002922778 Vs 17:01:26 Magnet Current for MAIN, Imag = 154.9794 A Vtrans = 1.549852 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:01:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939265 Vs 17:01:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002919411 Vs 17:01:42 Magnet Current for MAIN, Imag = 154.9797 A Vtrans = 1.549854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:01:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938244 Vs 17:01:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002928434 Vs 17:01:58 Magnet Current for MAIN, Imag = 154.9796 A Vtrans = 1.549853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:02:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939711 Vs 17:02:14 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002928423 Vs 17:02:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002931551 +- 0.000002168 Vs 17:02:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002931551 +- 0.000002168 Vs BL = -0.05863101 +- 0.00004336 Tm 17:02:14 Integrated Voltage Measurement... 17:02:14 Magnet Current for MAIN, Imag = 154.9797 A Vtrans = 1.549854 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:02:23 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002903825 Vs 17:02:31 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884777 Vs 17:02:32 Magnet Current for MAIN, Imag = 154.9798 A Vtrans = 1.549856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:02:39 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904313 Vs 17:02:47 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002886122 Vs 17:02:48 Magnet Current for MAIN, Imag = 154.9799 A Vtrans = 1.549857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:02:55 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893099 Vs 17:03:03 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002890350 Vs 17:03:04 Magnet Current for MAIN, Imag = 154.9799 A Vtrans = 1.549857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:03:11 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902905 Vs 17:03:19 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002890137 Vs 17:03:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002894441 +- 0.000001756 Vs 17:03:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002894441 +- 0.000001756 Vs BL = -0.05788882 +- 0.00003511 Tm Remeasure 17:03:19 Integrated Voltage Measurement... 17:03:20 Magnet Current for MAIN, Imag = 154.9796 A Vtrans = 1.549853 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:03:27 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902204 Vs 17:03:35 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002889359 Vs 17:03:36 Magnet Current for MAIN, Imag = 154.9798 A Vtrans = 1.549856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:03:43 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904293 Vs 17:03:51 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002880142 Vs 17:03:52 Magnet Current for MAIN, Imag = 154.9799 A Vtrans = 1.549857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:03:59 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002897648 Vs 17:04:07 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002891745 Vs 17:04:07 Magnet Current for MAIN, Imag = 154.9801 A Vtrans = 1.549858 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:04:15 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902347 Vs 17:04:22 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884168 Vs 17:04:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893988 +- 0.000001359 Vs 17:04:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893988 +- 0.000001359 Vs BL = -0.05787976 +- 0.00002718 Tm Remeasure 17:04:22 Integrated Voltage Measurement... 17:04:23 Magnet Current for MAIN, Imag = 154.9798 A Vtrans = 1.549856 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:04:31 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902321 Vs 17:04:38 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002886497 Vs 17:04:39 Magnet Current for MAIN, Imag = 154.9799 A Vtrans = 1.549857 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:04:47 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002903850 Vs 17:04:54 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002883937 Vs 17:04:55 Magnet Current for MAIN, Imag = 154.9801 A Vtrans = 1.549858 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:05:03 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904194 Vs 17:05:10 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002886344 Vs 17:05:11 Magnet Current for MAIN, Imag = 154.9803 A Vtrans = 1.549861 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:05:18 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002900533 Vs 17:05:26 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002883285 Vs 17:05:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893870 +- 0.000001234 Vs 17:05:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893870 +- 0.000001234 Vs BL = -0.05787740 +- 0.00002469 Tm Remeasure 17:05:26 Integrated Voltage Measurement... 17:05:27 Magnet Current for MAIN, Imag = 154.9804 A Vtrans = 1.549862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:05:34 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002899863 Vs 17:05:42 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002891935 Vs 17:05:43 Magnet Current for MAIN, Imag = 154.9802 A Vtrans = 1.549859 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:05:50 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002901103 Vs 17:05:58 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002890960 Vs 17:05:59 Magnet Current for MAIN, Imag = 154.9808 A Vtrans = 1.549865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:06:06 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902296 Vs 17:06:14 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887297 Vs 17:06:15 Magnet Current for MAIN, Imag = 154.9804 A Vtrans = 1.549862 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:06:22 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904459 Vs 17:06:30 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002882953 Vs 17:06:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002895108 +- 0.000000941 Vs 17:06:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002895108 +- 0.000000941 Vs BL = -0.05790217 +- 0.00001882 Tm 17:06:30 Integrated Voltage Measurement... 17:06:31 Magnet Current for MAIN, Imag = 154.9812 A Vtrans = 1.549869 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:06:39 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002821117 Vs 17:06:47 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809089 Vs 17:06:48 Magnet Current for MAIN, Imag = 154.9809 A Vtrans = 1.549867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:06:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002823532 Vs 17:07:03 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807758 Vs 17:07:04 Magnet Current for MAIN, Imag = 154.9807 A Vtrans = 1.549864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:07:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002824033 Vs 17:07:19 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002805254 Vs 17:07:20 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:07:28 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002824573 Vs 17:07:35 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002806188 Vs 17:07:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815193 +- 0.000000370 Vs 17:07:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002815193 +- 0.000000370 Vs BL = -0.05630386 +- 0.00000741 Tm 17:07:35 Integrated Voltage Measurement... 17:07:36 Magnet Current for MAIN, Imag = 154.9809 A Vtrans = 1.549867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:07:45 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002661606 Vs 17:07:52 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002651287 Vs 17:07:53 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:08:01 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002668072 Vs 17:08:08 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645243 Vs 17:08:09 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:08:16 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002656995 Vs 17:08:24 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649948 Vs 17:08:25 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:08:32 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002670896 Vs 17:08:40 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645054 Vs 17:08:40 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002656138 +- 0.000001647 Vs 17:08:40 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002656138 +- 0.000001647 Vs BL = -0.05312275 +- 0.00003294 Tm Remeasure 17:08:40 Integrated Voltage Measurement... 17:08:40 Magnet Current for MAIN, Imag = 154.9809 A Vtrans = 1.549867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:08:48 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663570 Vs 17:08:56 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648156 Vs 17:08:56 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:09:04 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002659071 Vs 17:09:12 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649510 Vs 17:09:12 Magnet Current for MAIN, Imag = 154.9812 A Vtrans = 1.549869 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:09:20 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665709 Vs 17:09:27 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649999 Vs 17:09:28 Magnet Current for MAIN, Imag = 154.9807 A Vtrans = 1.549864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:09:36 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663898 Vs 17:09:43 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647558 Vs 17:09:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002655934 +- 0.000001269 Vs 17:09:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002655934 +- 0.000001269 Vs BL = -0.05311868 +- 0.00002537 Tm Remeasure 17:09:43 Integrated Voltage Measurement... 17:09:44 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:09:51 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002666339 Vs 17:09:59 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002652391 Vs 17:10:00 Magnet Current for MAIN, Imag = 154.9808 A Vtrans = 1.549865 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:10:07 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002670935 Vs 17:10:15 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002646581 Vs 17:10:16 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:10:23 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002667167 Vs 17:10:31 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002646551 Vs 17:10:32 Magnet Current for MAIN, Imag = 154.9807 A Vtrans = 1.549864 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:10:39 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002656365 Vs 17:10:47 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002653640 Vs 17:10:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657496 +- 0.000001711 Vs 17:10:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657496 +- 0.000001711 Vs BL = -0.05314992 +- 0.00003422 Tm Remeasure 17:10:47 Integrated Voltage Measurement... 17:10:48 Magnet Current for MAIN, Imag = 154.9811 A Vtrans = 1.549868 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:10:55 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002669445 Vs 17:11:03 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002644133 Vs 17:11:04 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:11:11 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002640742 Vs 17:11:19 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648988 Vs 17:11:20 Magnet Current for MAIN, Imag = 154.9813 A Vtrans = 1.549870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:11:27 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664910 Vs 17:11:35 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649710 Vs 17:11:35 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:11:43 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002672677 Vs 17:11:51 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648066 Vs 17:11:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002654834 +- 0.000005916 Vs 17:11:51 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002654834 +- 0.000005916 Vs BL = -0.05309667 +- 0.00011832 Tm Remeasure 17:11:51 Integrated Voltage Measurement... 17:11:51 Magnet Current for MAIN, Imag = 154.9809 A Vtrans = 1.549867 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:11:59 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002668775 Vs 17:12:07 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645305 Vs 17:12:07 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:12:15 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002670621 Vs 17:12:22 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648506 Vs 17:12:23 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:12:31 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002660239 Vs 17:12:38 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002642067 Vs 17:12:39 Magnet Current for MAIN, Imag = 154.9812 A Vtrans = 1.549869 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:12:47 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002646141 Vs 17:12:54 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002650237 Vs 17:12:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002653986 +- 0.000004529 Vs 17:12:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002653986 +- 0.000004529 Vs BL = -0.05307973 +- 0.00009059 Tm 17:12:58 Position moved: 0.000000 m 17:12:58 Magnet system MAIN current ramping to 155.0000 A... 17:13:09 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:13:10 MAIN (V) Voltage Measurement, V = 6.146688 V 17:13:14 Temperature Measurement, Probe Number = 0, T = 27.135000 C 17:13:14 Temperature Measurement, Probe Number = 1, T = 28.746000 C 17:13:15 Temperature Measurement, Probe Number = 2, T = 29.279000 C 17:13:15 Temperature Measurement, Probe Number = 3, T = 29.032000 C 17:13:16 Temperature Measurement, Probe Number = 4, T = 30.880000 C 17:13:17 Temperature Measurement, Probe Number = 5, T = 26.533000 C 17:13:17 Sensor Voltage Measurement, Sensor Number = 0, V = 2.639987 V 17:13:17 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.639987 (V, A, ohm, ...), Measured Value = 122.999040 (C, atm, Hz, ...) 17:13:18 Sensor Voltage Measurement, Sensor Number = 1, V = 1.160286 V 17:13:18 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.160286 (V, A, ohm, ...), Measured Value = 12.021435 (C, atm, Hz, ...) 17:13:18 Magnet Test Parameter Measurements P0 = MAIN, Value = 154.98 P1 = MAIN (V), Value = 6.15 P2 = Yoke, Value = 27.14 P3 = Bottom Coil, Value = 28.75 P4 = Top Coil, Value = 29.28 P5 = Water In, Value = 29.03 P6 = Water Out, Value = 30.88 P7 = Ambient, Value = 26.53 P8 = Supply Pres(psi), Value = 123.00 P9 = Return Pres(psi), Value = 12.02 17:13:18 Integrated Voltage Measurement... 17:13:18 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:13:27 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002656681 Vs 17:13:35 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640753 Vs 17:13:36 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:13:43 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654154 Vs 17:13:51 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002634005 Vs 17:13:51 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:13:59 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002662503 Vs 17:14:07 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002643781 Vs 17:14:07 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:14:15 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002656737 Vs 17:14:23 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002650227 Vs 17:14:23 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002649855 +- 0.000003828 Vs 17:14:23 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002649855 +- 0.000003828 Vs BL = -0.05299710 +- 0.00007656 Tm Remeasure 17:14:23 Integrated Voltage Measurement... 17:14:23 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:14:31 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655078 Vs 17:14:39 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002641381 Vs 17:14:39 Magnet Current for MAIN, Imag = 154.9813 A Vtrans = 1.549870 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:14:47 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002653696 Vs 17:14:55 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002646578 Vs 17:14:56 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:15:03 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654902 Vs 17:15:11 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002642869 Vs 17:15:11 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:15:19 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002654715 Vs 17:15:27 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002636933 Vs 17:15:27 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002648269 +- 0.000001569 Vs 17:15:27 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002648269 +- 0.000001569 Vs BL = -0.05296538 +- 0.00003138 Tm Remeasure 17:15:27 Integrated Voltage Measurement... 17:15:27 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:15:35 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002656991 Vs 17:15:42 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640244 Vs 17:15:43 Magnet Current for MAIN, Imag = 154.9818 A Vtrans = 1.549875 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:15:51 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657645 Vs 17:15:58 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002639266 Vs 17:15:59 Magnet Current for MAIN, Imag = 154.9816 A Vtrans = 1.549873 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:16:07 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002662273 Vs 17:16:15 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002634669 Vs 17:16:15 Magnet Current for MAIN, Imag = 154.9818 A Vtrans = 1.549875 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:16:23 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002652984 Vs 17:16:30 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002638625 Vs 17:16:30 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002647837 +- 0.000001175 Vs 17:16:30 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002647837 +- 0.000001175 Vs BL = -0.05295674 +- 0.00002351 Tm Remeasure 17:16:30 Integrated Voltage Measurement... 17:16:31 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:16:39 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002657589 Vs 17:16:46 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002637645 Vs 17:16:47 Magnet Current for MAIN, Imag = 154.9814 A Vtrans = 1.549872 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:16:55 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002652275 Vs 17:17:02 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002637559 Vs 17:17:03 Magnet Current for MAIN, Imag = 154.9819 A Vtrans = 1.549877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:17:11 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002655361 Vs 17:17:18 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002635595 Vs 17:17:19 Magnet Current for MAIN, Imag = 154.9821 A Vtrans = 1.549878 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:17:27 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651551 Vs 17:17:34 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002646633 Vs 17:17:34 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002646776 +- 0.000001674 Vs 17:17:34 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002646776 +- 0.000001674 Vs BL = -0.05293552 +- 0.00003349 Tm Remeasure 17:17:34 Integrated Voltage Measurement... 17:17:35 Magnet Current for MAIN, Imag = 154.9819 A Vtrans = 1.549877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:17:43 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002661466 Vs 17:17:50 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002646513 Vs 17:17:51 Magnet Current for MAIN, Imag = 154.9817 A Vtrans = 1.549874 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:17:58 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002662733 Vs 17:18:06 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002640852 Vs 17:18:06 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:18:14 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002658158 Vs 17:18:22 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002643580 Vs 17:18:22 Magnet Current for MAIN, Imag = 154.9819 A Vtrans = 1.549877 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:18:30 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651323 Vs 17:18:37 Integrated Voltage Measurement X0 = -0.0350000 m, Delta X = -0.0050000 m VT = 0.002643806 Vs 17:18:37 Integrated Voltage Average and RMS of Measurements X0 = -0.0350000 m, Delta X = 0.0050000 m VT = -0.002651054 +- 0.000002312 Vs 17:18:37 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002651054 +- 0.000002312 Vs BL = -0.05302108 +- 0.00004623 Tm 17:18:37 Integrated Voltage Measurement... 17:18:38 Magnet Current for MAIN, Imag = 154.9823 A Vtrans = 1.549880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:18:47 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002820539 Vs 17:18:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801149 Vs 17:18:55 Magnet Current for MAIN, Imag = 154.9818 A Vtrans = 1.549875 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:19:03 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002823474 Vs 17:19:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002805639 Vs 17:19:11 Magnet Current for MAIN, Imag = 154.9821 A Vtrans = 1.549878 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:19:19 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002822702 Vs 17:19:26 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002804236 Vs 17:19:27 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:19:35 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002825216 Vs 17:19:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803149 Vs 17:19:42 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002813263 +- 0.000001450 Vs 17:19:42 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002813263 +- 0.000001450 Vs BL = -0.05626526 +- 0.00002900 Tm Remeasure 17:19:42 Integrated Voltage Measurement... 17:19:43 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:19:51 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002822354 Vs 17:19:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002799678 Vs 17:19:59 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:20:07 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815900 Vs 17:20:14 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002804785 Vs 17:20:15 Magnet Current for MAIN, Imag = 154.9823 A Vtrans = 1.549880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:20:23 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002818469 Vs 17:20:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002805044 Vs 17:20:31 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:20:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815137 Vs 17:20:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803371 Vs 17:20:46 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002810592 +- 0.000000920 Vs 17:20:46 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002810592 +- 0.000000920 Vs BL = -0.05621184 +- 0.00001841 Tm Remeasure 17:20:46 Integrated Voltage Measurement... 17:20:47 Magnet Current for MAIN, Imag = 154.9821 A Vtrans = 1.549878 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:20:54 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002820776 Vs 17:21:02 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002801517 Vs 17:21:03 Magnet Current for MAIN, Imag = 154.9826 A Vtrans = 1.549883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:21:11 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002821416 Vs 17:21:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002805562 Vs 17:21:19 Magnet Current for MAIN, Imag = 154.9823 A Vtrans = 1.549880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:21:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002817123 Vs 17:21:34 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002805627 Vs 17:21:35 Magnet Current for MAIN, Imag = 154.9823 A Vtrans = 1.549880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:21:43 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002813510 Vs 17:21:50 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803740 Vs 17:21:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002811159 +- 0.000001725 Vs 17:21:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002811159 +- 0.000001725 Vs BL = -0.05622317 +- 0.00003449 Tm Remeasure 17:21:50 Integrated Voltage Measurement... 17:21:51 Magnet Current for MAIN, Imag = 154.9824 A Vtrans = 1.549882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:21:58 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815906 Vs 17:22:06 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002800439 Vs 17:22:07 Magnet Current for MAIN, Imag = 154.9828 A Vtrans = 1.549885 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:22:14 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815852 Vs 17:22:22 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002802563 Vs 17:22:23 Magnet Current for MAIN, Imag = 154.9823 A Vtrans = 1.549880 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:22:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002819457 Vs 17:22:38 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002803064 Vs 17:22:39 Magnet Current for MAIN, Imag = 154.9824 A Vtrans = 1.549882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:22:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002815541 Vs 17:22:54 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0050000 m VT = 0.002802122 Vs 17:22:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0050000 m VT = -0.002809368 +- 0.000001154 Vs 17:22:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002809368 +- 0.000001154 Vs BL = -0.05618736 +- 0.00002307 Tm 17:22:54 Integrated Voltage Measurement... 17:22:55 Magnet Current for MAIN, Imag = 154.9824 A Vtrans = 1.549882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:23:03 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002900222 Vs 17:23:11 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002889086 Vs 17:23:12 Magnet Current for MAIN, Imag = 154.9826 A Vtrans = 1.549883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:23:20 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002898513 Vs 17:23:27 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002888618 Vs 17:23:28 Magnet Current for MAIN, Imag = 154.9824 A Vtrans = 1.549882 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:23:35 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002887538 Vs 17:23:43 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887188 Vs 17:23:44 Magnet Current for MAIN, Imag = 154.9826 A Vtrans = 1.549883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:23:51 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002885154 Vs 17:23:59 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887022 Vs 17:23:59 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002890417 +- 0.000003739 Vs 17:23:59 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002890417 +- 0.000003739 Vs BL = -0.05780835 +- 0.00007479 Tm Remeasure 17:23:59 Integrated Voltage Measurement... 17:23:59 Magnet Current for MAIN, Imag = 154.9822 A Vtrans = 1.549879 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:24:07 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002900876 Vs 17:24:15 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887439 Vs 17:24:15 Magnet Current for MAIN, Imag = 154.9831 A Vtrans = 1.549888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:24:23 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002899148 Vs 17:24:31 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002883443 Vs 17:24:31 Magnet Current for MAIN, Imag = 154.9827 A Vtrans = 1.549884 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:24:39 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896966 Vs 17:24:46 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002884449 Vs 17:24:47 Magnet Current for MAIN, Imag = 154.9826 A Vtrans = 1.549883 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:24:55 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002895780 Vs 17:25:03 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002884065 Vs 17:25:03 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002891521 +- 0.000001598 Vs 17:25:03 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002891521 +- 0.000001598 Vs BL = -0.05783041 +- 0.00003197 Tm Remeasure 17:25:03 Integrated Voltage Measurement... 17:25:03 Magnet Current for MAIN, Imag = 154.9832 A Vtrans = 1.549889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:25:11 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002897736 Vs 17:25:18 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886224 Vs 17:25:19 Magnet Current for MAIN, Imag = 154.9828 A Vtrans = 1.549885 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:25:27 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002902373 Vs 17:25:34 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002888186 Vs 17:25:35 Magnet Current for MAIN, Imag = 154.9828 A Vtrans = 1.549885 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:25:43 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002899102 Vs 17:25:50 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002885084 Vs 17:25:51 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:25:59 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002898949 Vs 17:26:06 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002889145 Vs 17:26:06 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002893350 +- 0.000001384 Vs 17:26:06 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893350 +- 0.000001384 Vs BL = -0.05786700 +- 0.00002769 Tm Remeasure 17:26:06 Integrated Voltage Measurement... 17:26:07 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:26:15 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002901464 Vs 17:26:22 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886559 Vs 17:26:23 Magnet Current for MAIN, Imag = 154.9831 A Vtrans = 1.549888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:26:31 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002904641 Vs 17:26:38 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887719 Vs 17:26:39 Magnet Current for MAIN, Imag = 154.9829 A Vtrans = 1.549887 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:26:46 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002899423 Vs 17:26:54 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002881532 Vs 17:26:55 Magnet Current for MAIN, Imag = 154.9831 A Vtrans = 1.549888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:27:02 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002898315 Vs 17:27:10 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886760 Vs 17:27:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002893302 +- 0.000002082 Vs 17:27:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893302 +- 0.000002082 Vs BL = -0.05786603 +- 0.00004165 Tm Remeasure 17:27:10 Integrated Voltage Measurement... 17:27:11 Magnet Current for MAIN, Imag = 154.9833 A Vtrans = 1.549890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:27:18 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002902183 Vs 17:27:26 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002884123 Vs 17:27:26 Magnet Current for MAIN, Imag = 154.9836 A Vtrans = 1.549893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:27:34 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002903139 Vs 17:27:42 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002886714 Vs 17:27:42 Magnet Current for MAIN, Imag = 154.9832 A Vtrans = 1.549889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:27:50 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002896143 Vs 17:27:57 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002883148 Vs 17:27:58 Magnet Current for MAIN, Imag = 154.9832 A Vtrans = 1.549889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:28:06 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002900216 Vs 17:28:13 Integrated Voltage Measurement X0 = -0.0250000 m, Delta X = -0.0050000 m VT = 0.002887473 Vs 17:28:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0250000 m, Delta X = 0.0050000 m VT = -0.002892892 +- 0.000001978 Vs 17:28:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002892892 +- 0.000001978 Vs BL = -0.05785785 +- 0.00003957 Tm 17:28:13 Integrated Voltage Measurement... 17:28:14 Magnet Current for MAIN, Imag = 154.9832 A Vtrans = 1.549889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:28:23 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002938994 Vs 17:28:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002915846 Vs 17:28:31 Magnet Current for MAIN, Imag = 154.9836 A Vtrans = 1.549893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:28:39 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002933418 Vs 17:28:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002922038 Vs 17:28:47 Magnet Current for MAIN, Imag = 154.9832 A Vtrans = 1.549889 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:28:55 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002940890 Vs 17:29:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919318 Vs 17:29:03 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:29:11 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002940768 Vs 17:29:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924008 Vs 17:29:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002929410 +- 0.000002009 Vs 17:29:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002929410 +- 0.000002009 Vs BL = -0.05858820 +- 0.00004017 Tm Remeasure 17:29:18 Integrated Voltage Measurement... 17:29:19 Magnet Current for MAIN, Imag = 154.9831 A Vtrans = 1.549888 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:29:26 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939845 Vs 17:29:34 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002914563 Vs 17:29:35 Magnet Current for MAIN, Imag = 154.9836 A Vtrans = 1.549893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:29:42 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937011 Vs 17:29:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924794 Vs 17:29:51 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:29:58 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002932819 Vs 17:30:06 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002909579 Vs 17:30:06 Magnet Current for MAIN, Imag = 154.9833 A Vtrans = 1.549890 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:30:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002933765 Vs 17:30:22 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919626 Vs 17:30:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002926500 +- 0.000003465 Vs 17:30:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002926500 +- 0.000003465 Vs BL = -0.05853000 +- 0.00006930 Tm Remeasure 17:30:22 Integrated Voltage Measurement... 17:30:22 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:30:30 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002944616 Vs 17:30:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924410 Vs 17:30:38 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:30:46 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002949888 Vs 17:30:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924445 Vs 17:30:54 Magnet Current for MAIN, Imag = 154.9834 A Vtrans = 1.549892 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:31:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002938781 Vs 17:31:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002934758 Vs 17:31:10 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:31:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002941036 Vs 17:31:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002933033 Vs 17:31:25 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002936371 +- 0.000001082 Vs 17:31:25 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002936371 +- 0.000001082 Vs BL = -0.05872742 +- 0.00002164 Tm Remeasure 17:31:25 Integrated Voltage Measurement... 17:31:26 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:31:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002944256 Vs 17:31:41 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002925924 Vs 17:31:42 Magnet Current for MAIN, Imag = 154.9839 A Vtrans = 1.549897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:31:49 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002928515 Vs 17:31:57 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002919004 Vs 17:31:58 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:32:05 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939778 Vs 17:32:13 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002926598 Vs 17:32:14 Magnet Current for MAIN, Imag = 154.9839 A Vtrans = 1.549897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:32:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939082 Vs 17:32:29 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002941536 Vs 17:32:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002933087 +- 0.000005983 Vs 17:32:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002933087 +- 0.000005983 Vs BL = -0.05866173 +- 0.00011966 Tm Remeasure 17:32:29 Integrated Voltage Measurement... 17:32:30 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:32:37 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002937362 Vs 17:32:45 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002925968 Vs 17:32:46 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:32:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935320 Vs 17:33:01 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002909278 Vs 17:33:01 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:33:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002935950 Vs 17:33:17 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002930899 Vs 17:33:18 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:33:25 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002939075 Vs 17:33:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0050000 m VT = 0.002924928 Vs 17:33:33 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0050000 m VT = -0.002929847 +- 0.000004408 Vs 17:33:33 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002929847 +- 0.000004408 Vs BL = -0.05859695 +- 0.00008816 Tm 17:33:33 Integrated Voltage Measurement... 17:33:34 Magnet Current for MAIN, Imag = 154.9836 A Vtrans = 1.549893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:33:42 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953794 Vs 17:33:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002942310 Vs 17:33:51 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:33:58 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953687 Vs 17:34:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938151 Vs 17:34:07 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:34:14 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002952652 Vs 17:34:22 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002946389 Vs 17:34:22 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:34:30 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955536 Vs 17:34:38 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002941270 Vs 17:34:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002947974 +- 0.000001304 Vs 17:34:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947974 +- 0.000001304 Vs BL = -0.05895947 +- 0.00002608 Tm Remeasure 17:34:38 Integrated Voltage Measurement... 17:34:38 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:34:46 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956458 Vs 17:34:54 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938948 Vs 17:34:54 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:35:02 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957095 Vs 17:35:10 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002937487 Vs 17:35:10 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:35:18 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002955067 Vs 17:35:25 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938962 Vs 17:35:26 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:35:34 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002957219 Vs 17:35:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002941971 Vs 17:35:41 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002947901 +- 0.000001008 Vs 17:35:41 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947901 +- 0.000001008 Vs BL = -0.05895802 +- 0.00002017 Tm Remeasure 17:35:41 Integrated Voltage Measurement... 17:35:42 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:35:50 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954676 Vs 17:35:57 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002935438 Vs 17:35:58 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:36:06 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002958106 Vs 17:36:13 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002944429 Vs 17:36:14 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:36:21 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953565 Vs 17:36:29 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938976 Vs 17:36:30 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:36:37 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954230 Vs 17:36:45 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002943093 Vs 17:36:45 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002947814 +- 0.000002379 Vs 17:36:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947814 +- 0.000002379 Vs BL = -0.05895628 +- 0.00004757 Tm Remeasure 17:36:45 Integrated Voltage Measurement... 17:36:46 Magnet Current for MAIN, Imag = 154.9844 A Vtrans = 1.549902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:36:53 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954044 Vs 17:37:01 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002938669 Vs 17:37:02 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:37:09 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002953914 Vs 17:37:17 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002939095 Vs 17:37:18 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:37:25 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002954064 Vs 17:37:33 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002936952 Vs 17:37:34 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:37:41 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002956473 Vs 17:37:49 Integrated Voltage Measurement X0 = -0.0150000 m, Delta X = -0.0050000 m VT = 0.002942807 Vs 17:37:49 Integrated Voltage Average and RMS of Measurements X0 = -0.0150000 m, Delta X = 0.0050000 m VT = -0.002947002 +- 0.000001570 Vs 17:37:49 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947002 +- 0.000001570 Vs BL = -0.05894005 +- 0.00003139 Tm 17:37:49 Integrated Voltage Measurement... 17:37:49 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:37:58 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960437 Vs 17:38:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002948688 Vs 17:38:06 Magnet Current for MAIN, Imag = 154.9836 A Vtrans = 1.549893 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:38:14 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002956634 Vs 17:38:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002940647 Vs 17:38:22 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:38:30 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957797 Vs 17:38:38 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002948659 Vs 17:38:38 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:38:46 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958285 Vs 17:38:54 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943920 Vs 17:38:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002951883 +- 0.000002242 Vs 17:38:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951883 +- 0.000002242 Vs BL = -0.05903767 +- 0.00004485 Tm Remeasure 17:38:54 Integrated Voltage Measurement... 17:38:54 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:39:02 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958392 Vs 17:39:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002946348 Vs 17:39:10 Magnet Current for MAIN, Imag = 154.9839 A Vtrans = 1.549897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:39:18 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957883 Vs 17:39:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944203 Vs 17:39:26 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:39:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002955962 Vs 17:39:41 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943085 Vs 17:39:42 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:39:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002956168 Vs 17:39:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002942910 Vs 17:39:57 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002950619 +- 0.000001184 Vs 17:39:57 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002950619 +- 0.000001184 Vs BL = -0.05901237 +- 0.00002369 Tm Remeasure 17:39:57 Integrated Voltage Measurement... 17:39:58 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:40:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002963275 Vs 17:40:13 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002947252 Vs 17:40:14 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:40:21 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960813 Vs 17:40:29 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002944899 Vs 17:40:30 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:40:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960320 Vs 17:40:45 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002939515 Vs 17:40:46 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:40:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002959404 Vs 17:41:01 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002946373 Vs 17:41:01 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002952731 +- 0.000001895 Vs 17:41:01 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952731 +- 0.000001895 Vs BL = -0.05905463 +- 0.00003791 Tm Remeasure 17:41:01 Integrated Voltage Measurement... 17:41:02 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:41:09 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002957494 Vs 17:41:17 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002943515 Vs 17:41:18 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:41:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002960811 Vs 17:41:33 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945660 Vs 17:41:34 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:41:41 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002955870 Vs 17:41:49 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002946222 Vs 17:41:49 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:41:57 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002958929 Vs 17:42:05 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0050000 m VT = 0.002945265 Vs 17:42:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0050000 m VT = -0.002951721 +- 0.000001045 Vs 17:42:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951721 +- 0.000001045 Vs BL = -0.05903442 +- 0.00002091 Tm 17:42:05 Integrated Voltage Measurement... 17:42:05 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:42:14 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002960503 Vs 17:42:22 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947180 Vs 17:42:23 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:42:30 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002957626 Vs 17:42:38 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002944941 Vs 17:42:38 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:42:46 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002957374 Vs 17:42:54 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002946947 Vs 17:42:54 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:43:02 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959091 Vs 17:43:10 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002944645 Vs 17:43:10 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952289 +- 0.000000951 Vs 17:43:10 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952289 +- 0.000000951 Vs BL = -0.05904577 +- 0.00001901 Tm Remeasure 17:43:10 Integrated Voltage Measurement... 17:43:10 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:43:18 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959313 Vs 17:43:25 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948722 Vs 17:43:26 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:43:34 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002957495 Vs 17:43:41 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002942540 Vs 17:43:42 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:43:49 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959225 Vs 17:43:57 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002947706 Vs 17:43:58 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:44:05 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959919 Vs 17:44:13 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948445 Vs 17:44:13 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952920 +- 0.000001697 Vs 17:44:13 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952920 +- 0.000001697 Vs BL = -0.05905841 +- 0.00003394 Tm Remeasure 17:44:13 Integrated Voltage Measurement... 17:44:14 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:44:21 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002959835 Vs 17:44:29 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002942988 Vs 17:44:29 Magnet Current for MAIN, Imag = 154.9844 A Vtrans = 1.549902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:44:37 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002963977 Vs 17:44:44 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002939750 Vs 17:44:45 Magnet Current for MAIN, Imag = 154.9839 A Vtrans = 1.549897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:44:53 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002962557 Vs 17:45:00 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002942815 Vs 17:45:01 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:45:09 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002961993 Vs 17:45:16 Integrated Voltage Measurement X0 = -0.0050000 m, Delta X = -0.0050000 m VT = 0.002948412 Vs 17:45:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0050000 m, Delta X = 0.0050000 m VT = -0.002952791 +- 0.000001465 Vs 17:45:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952791 +- 0.000001465 Vs BL = -0.05905582 +- 0.00002931 Tm 17:45:16 Integrated Voltage Measurement... 17:45:17 Magnet Current for MAIN, Imag = 154.9837 A Vtrans = 1.549894 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:45:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002959784 Vs 17:45:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002947511 Vs 17:45:34 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:45:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960919 Vs 17:45:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002945902 Vs 17:45:50 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:45:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002960935 Vs 17:46:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002945904 Vs 17:46:06 Magnet Current for MAIN, Imag = 154.9843 A Vtrans = 1.549900 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:46:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002963228 Vs 17:46:21 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0050000 m VT = 0.002944910 Vs 17:46:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0050000 m VT = -0.002953637 +- 0.000000267 Vs 17:46:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953637 +- 0.000000267 Vs BL = -0.05907273 +- 0.00000534 Tm 17:46:21 Integrated Voltage Measurement... 17:46:22 Magnet Current for MAIN, Imag = 154.9844 A Vtrans = 1.549902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:46:31 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958966 Vs 17:46:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947034 Vs 17:46:39 Magnet Current for MAIN, Imag = 154.9839 A Vtrans = 1.549897 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:46:46 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960325 Vs 17:46:54 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002950745 Vs 17:46:55 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:47:03 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962635 Vs 17:47:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002950488 Vs 17:47:11 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:47:18 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002958481 Vs 17:47:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002949259 Vs 17:47:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002954741 +- 0.000001391 Vs 17:47:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002954741 +- 0.000001391 Vs BL = -0.05909483 +- 0.00002781 Tm Remeasure 17:47:26 Integrated Voltage Measurement... 17:47:27 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:47:34 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962266 Vs 17:47:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002946662 Vs 17:47:43 Magnet Current for MAIN, Imag = 154.9842 A Vtrans = 1.549899 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:47:50 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960082 Vs 17:47:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947956 Vs 17:47:59 Magnet Current for MAIN, Imag = 154.9838 A Vtrans = 1.549895 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:48:06 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960627 Vs 17:48:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945140 Vs 17:48:14 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:48:22 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002957727 Vs 17:48:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002945190 Vs 17:48:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953206 +- 0.000001162 Vs 17:48:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953206 +- 0.000001162 Vs BL = -0.05906413 +- 0.00002324 Tm Remeasure 17:48:30 Integrated Voltage Measurement... 17:48:30 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:48:38 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002960908 Vs 17:48:45 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002949378 Vs 17:48:46 Magnet Current for MAIN, Imag = 154.9841 A Vtrans = 1.549898 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:48:54 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961714 Vs 17:49:01 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002948890 Vs 17:49:02 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:49:10 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959364 Vs 17:49:17 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002951454 Vs 17:49:18 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:49:26 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002959946 Vs 17:49:33 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002943564 Vs 17:49:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002954402 +- 0.000001531 Vs 17:49:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002954402 +- 0.000001531 Vs BL = -0.05908804 +- 0.00003063 Tm Remeasure 17:49:33 Integrated Voltage Measurement... 17:49:34 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:49:42 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961344 Vs 17:49:49 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002942360 Vs 17:49:50 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:49:58 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961977 Vs 17:50:05 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002947973 Vs 17:50:06 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:50:14 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002961649 Vs 17:50:21 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002948823 Vs 17:50:22 Magnet Current for MAIN, Imag = 154.9844 A Vtrans = 1.549902 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:50:30 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002962838 Vs 17:50:37 Integrated Voltage Measurement X0 = 0.0050000 m, Delta X = -0.0050000 m VT = 0.002942721 Vs 17:50:37 Integrated Voltage Average and RMS of Measurements X0 = 0.0050000 m, Delta X = 0.0050000 m VT = -0.002953711 +- 0.000001436 Vs 17:50:37 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0050000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002953711 +- 0.000001436 Vs BL = -0.05907421 +- 0.00002872 Tm 17:50:37 Integrated Voltage Measurement... 17:50:38 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:50:47 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002961620 Vs 17:50:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943376 Vs 17:50:55 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:51:03 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002956699 Vs 17:51:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942431 Vs 17:51:11 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:51:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002962703 Vs 17:51:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942371 Vs 17:51:27 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:51:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002949951 Vs 17:51:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002939662 Vs 17:51:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002949852 +- 0.000003153 Vs 17:51:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002949852 +- 0.000003153 Vs BL = -0.05899703 +- 0.00006305 Tm Remeasure 17:51:42 Integrated Voltage Measurement... 17:51:43 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:51:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002960364 Vs 17:51:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002941890 Vs 17:51:59 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:52:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002959465 Vs 17:52:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002945091 Vs 17:52:15 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:52:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002960145 Vs 17:52:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002946628 Vs 17:52:31 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:52:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002963929 Vs 17:52:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943920 Vs 17:52:46 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002952679 +- 0.000001075 Vs 17:52:46 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952679 +- 0.000001075 Vs BL = -0.05905358 +- 0.00002149 Tm Remeasure 17:52:46 Integrated Voltage Measurement... 17:52:47 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:52:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002955884 Vs 17:53:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002943499 Vs 17:53:03 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:53:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002956407 Vs 17:53:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002946636 Vs 17:53:19 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:53:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002959265 Vs 17:53:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002940770 Vs 17:53:35 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:53:42 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002962073 Vs 17:53:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002947047 Vs 17:53:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002951448 +- 0.000001925 Vs 17:53:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951448 +- 0.000001925 Vs BL = -0.05902895 +- 0.00003850 Tm Remeasure 17:53:50 Integrated Voltage Measurement... 17:53:50 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:53:58 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002958441 Vs 17:54:06 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002940753 Vs 17:54:06 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:54:14 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002964193 Vs 17:54:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002942983 Vs 17:54:22 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:54:30 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002953670 Vs 17:54:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002946646 Vs 17:54:38 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:54:46 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002965606 Vs 17:54:54 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002946371 Vs 17:54:54 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002952333 +- 0.000002606 Vs 17:54:54 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002952333 +- 0.000002606 Vs BL = -0.05904666 +- 0.00005211 Tm Remeasure 17:54:54 Integrated Voltage Measurement... 17:54:55 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:55:02 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002959921 Vs 17:55:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002948282 Vs 17:55:10 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:55:18 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002959491 Vs 17:55:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002944370 Vs 17:55:26 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:55:34 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002957481 Vs 17:55:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002940087 Vs 17:55:42 Magnet Current for MAIN, Imag = 154.9846 A Vtrans = 1.549903 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:55:50 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002958924 Vs 17:55:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0050000 m VT = 0.002944596 Vs 17:55:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0050000 m VT = -0.002951644 +- 0.000001892 Vs 17:55:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002951644 +- 0.000001892 Vs BL = -0.05903288 +- 0.00003784 Tm 17:55:57 Integrated Voltage Measurement... 17:55:58 Magnet Current for MAIN, Imag = 154.9847 A Vtrans = 1.549904 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:56:07 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002950919 Vs 17:56:15 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938699 Vs 17:56:15 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:56:23 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002952233 Vs 17:56:31 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002943189 Vs 17:56:31 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:56:39 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953689 Vs 17:56:47 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002935696 Vs 17:56:47 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:56:55 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954006 Vs 17:57:02 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002934709 Vs 17:57:02 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002945392 +- 0.000001349 Vs 17:57:02 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002945392 +- 0.000001349 Vs BL = -0.05890784 +- 0.00002698 Tm Remeasure 17:57:02 Integrated Voltage Measurement... 17:57:03 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:57:11 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002956220 Vs 17:57:18 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002939821 Vs 17:57:19 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:57:27 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002952226 Vs 17:57:34 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002944629 Vs 17:57:35 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:57:42 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002956496 Vs 17:57:50 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002940615 Vs 17:57:51 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:57:59 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002958161 Vs 17:58:06 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002933709 Vs 17:58:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002947735 +- 0.000001058 Vs 17:58:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002947735 +- 0.000001058 Vs BL = -0.05895469 +- 0.00002115 Tm Remeasure 17:58:06 Integrated Voltage Measurement... 17:58:07 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:58:15 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002955094 Vs 17:58:22 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002928923 Vs 17:58:23 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:58:31 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002952571 Vs 17:58:38 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002931887 Vs 17:58:39 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:58:47 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954266 Vs 17:58:54 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002938506 Vs 17:58:55 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:59:03 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002956441 Vs 17:59:10 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002940131 Vs 17:59:10 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002944728 +- 0.000002695 Vs 17:59:10 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002944728 +- 0.000002695 Vs BL = -0.05889455 +- 0.00005390 Tm Remeasure 17:59:10 Integrated Voltage Measurement... 17:59:11 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:59:19 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002955251 Vs 17:59:26 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002937367 Vs 17:59:27 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:59:35 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002953258 Vs 17:59:42 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002942039 Vs 17:59:43 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 17:59:51 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002951130 Vs 17:59:58 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002935321 Vs 17:59:59 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:00:06 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002954257 Vs 18:00:14 Integrated Voltage Measurement X0 = 0.0150000 m, Delta X = -0.0050000 m VT = 0.002941190 Vs 18:00:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0150000 m, Delta X = 0.0050000 m VT = -0.002946227 +- 0.000001822 Vs 18:00:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0150000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002946227 +- 0.000001822 Vs BL = -0.05892453 +- 0.00003644 Tm 18:00:14 Integrated Voltage Measurement... 18:00:15 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:00:24 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002937295 Vs 18:00:31 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002926794 Vs 18:00:32 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:00:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938268 Vs 18:00:47 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002918812 Vs 18:00:48 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:00:55 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936717 Vs 18:01:03 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002925798 Vs 18:01:04 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:01:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002939035 Vs 18:01:19 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002920837 Vs 18:01:19 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002930445 +- 0.000001333 Vs 18:01:19 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002930445 +- 0.000001333 Vs BL = -0.05860889 +- 0.00002666 Tm Remeasure 18:01:19 Integrated Voltage Measurement... 18:01:20 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:01:27 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002937089 Vs 18:01:35 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002927566 Vs 18:01:35 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:01:43 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938438 Vs 18:01:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002922587 Vs 18:01:51 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:01:59 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936865 Vs 18:02:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002922562 Vs 18:02:07 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:02:15 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002943566 Vs 18:02:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002929431 Vs 18:02:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002932263 +- 0.000002622 Vs 18:02:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002932263 +- 0.000002622 Vs BL = -0.05864525 +- 0.00005245 Tm Remeasure 18:02:22 Integrated Voltage Measurement... 18:02:23 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:02:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002934945 Vs 18:02:38 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923777 Vs 18:02:39 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:02:46 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002933190 Vs 18:02:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002922044 Vs 18:02:54 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:03:02 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940934 Vs 18:03:10 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002928947 Vs 18:03:10 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:03:18 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940665 Vs 18:03:26 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002920187 Vs 18:03:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002930586 +- 0.000002707 Vs 18:03:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002930586 +- 0.000002707 Vs BL = -0.05861172 +- 0.00005413 Tm Remeasure 18:03:26 Integrated Voltage Measurement... 18:03:26 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:03:34 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002936309 Vs 18:03:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002919404 Vs 18:03:42 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:03:50 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002941784 Vs 18:03:57 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002921148 Vs 18:03:58 Magnet Current for MAIN, Imag = 154.9858 A Vtrans = 1.549915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:04:06 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002940357 Vs 18:04:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923149 Vs 18:04:14 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:04:22 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002937670 Vs 18:04:29 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002924222 Vs 18:04:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002930505 +- 0.000001557 Vs 18:04:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002930505 +- 0.000001557 Vs BL = -0.05861011 +- 0.00003113 Tm Remeasure 18:04:29 Integrated Voltage Measurement... 18:04:30 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:04:37 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002944257 Vs 18:04:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002921815 Vs 18:04:46 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:04:53 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002938908 Vs 18:05:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002929774 Vs 18:05:02 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:05:09 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002941117 Vs 18:05:17 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002926120 Vs 18:05:18 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:05:25 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002945584 Vs 18:05:33 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0050000 m VT = 0.002923706 Vs 18:05:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0050000 m VT = -0.002933910 +- 0.000000628 Vs 18:05:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002933910 +- 0.000000628 Vs BL = -0.05867820 +- 0.00001255 Tm 18:05:33 Integrated Voltage Measurement... 18:05:34 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:05:42 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002894962 Vs 18:05:50 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002891176 Vs 18:05:51 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:05:58 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002897774 Vs 18:06:06 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884745 Vs 18:06:07 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:06:14 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902181 Vs 18:06:22 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002888587 Vs 18:06:22 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:06:30 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002905058 Vs 18:06:38 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884552 Vs 18:06:38 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893629 +- 0.000001612 Vs 18:06:38 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893629 +- 0.000001612 Vs BL = -0.05787259 +- 0.00003223 Tm Remeasure 18:06:38 Integrated Voltage Measurement... 18:06:38 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:06:46 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902636 Vs 18:06:54 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002886553 Vs 18:06:54 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:07:02 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002906304 Vs 18:07:10 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885624 Vs 18:07:10 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:07:18 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002901348 Vs 18:07:26 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887327 Vs 18:07:26 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:07:34 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002906579 Vs 18:07:42 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002892367 Vs 18:07:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002896092 +- 0.000002048 Vs 18:07:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002896092 +- 0.000002048 Vs BL = -0.05792184 +- 0.00004095 Tm Remeasure 18:07:42 Integrated Voltage Measurement... 18:07:42 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:07:50 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902067 Vs 18:07:58 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887378 Vs 18:07:58 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:08:06 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002905671 Vs 18:08:13 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002889564 Vs 18:08:14 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:08:22 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002899827 Vs 18:08:29 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002886903 Vs 18:08:30 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:08:37 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002898663 Vs 18:08:45 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002893058 Vs 18:08:45 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002895391 +- 0.000001560 Vs 18:08:45 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002895391 +- 0.000001560 Vs BL = -0.05790783 +- 0.00003119 Tm Remeasure 18:08:45 Integrated Voltage Measurement... 18:08:46 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:08:54 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904847 Vs 18:09:01 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885190 Vs 18:09:02 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:09:09 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002901321 Vs 18:09:17 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884640 Vs 18:09:18 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:09:25 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002904771 Vs 18:09:33 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002892036 Vs 18:09:34 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:09:42 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002898646 Vs 18:09:49 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885066 Vs 18:09:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002894565 +- 0.000002489 Vs 18:09:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002894565 +- 0.000002489 Vs BL = -0.05789130 +- 0.00004979 Tm Remeasure 18:09:49 Integrated Voltage Measurement... 18:09:50 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:09:57 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002902655 Vs 18:10:05 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002885246 Vs 18:10:06 Magnet Current for MAIN, Imag = 154.9859 A Vtrans = 1.549917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:10:13 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002899550 Vs 18:10:21 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002887907 Vs 18:10:22 Magnet Current for MAIN, Imag = 154.9858 A Vtrans = 1.549915 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:10:29 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002905759 Vs 18:10:37 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002882679 Vs 18:10:38 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:10:45 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002900853 Vs 18:10:53 Integrated Voltage Measurement X0 = 0.0250000 m, Delta X = -0.0050000 m VT = 0.002884984 Vs 18:10:53 Integrated Voltage Average and RMS of Measurements X0 = 0.0250000 m, Delta X = 0.0050000 m VT = -0.002893704 +- 0.000000485 Vs 18:10:53 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0250000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002893704 +- 0.000000485 Vs BL = -0.05787408 +- 0.00000971 Tm 18:10:53 Integrated Voltage Measurement... 18:10:54 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:11:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002812020 Vs 18:11:10 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002804433 Vs 18:11:11 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:11:18 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002823105 Vs 18:11:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002803487 Vs 18:11:27 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:11:34 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002813120 Vs 18:11:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807682 Vs 18:11:43 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:11:50 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002837246 Vs 18:11:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002808231 Vs 18:11:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002813665 +- 0.000005538 Vs 18:11:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002813665 +- 0.000005538 Vs BL = -0.05627331 +- 0.00011077 Tm Remeasure 18:11:58 Integrated Voltage Measurement... 18:11:59 Magnet Current for MAIN, Imag = 154.9859 A Vtrans = 1.549917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:12:06 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002845801 Vs 18:12:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807964 Vs 18:12:15 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:12:22 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002811685 Vs 18:12:30 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807015 Vs 18:12:30 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:12:38 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002833161 Vs 18:12:46 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809732 Vs 18:12:46 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:12:54 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002804927 Vs 18:13:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002804777 Vs 18:13:01 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815633 +- 0.000008889 Vs 18:13:01 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002815633 +- 0.000008889 Vs BL = -0.05631265 +- 0.00017778 Tm Remeasure 18:13:01 Integrated Voltage Measurement... 18:13:02 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:13:10 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002832207 Vs 18:13:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002802625 Vs 18:13:18 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:13:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002816716 Vs 18:13:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807048 Vs 18:13:34 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:13:42 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002809818 Vs 18:13:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807263 Vs 18:13:50 Magnet Current for MAIN, Imag = 154.9859 A Vtrans = 1.549917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:13:58 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002816746 Vs 18:14:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002806373 Vs 18:14:05 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002812349 +- 0.000003202 Vs 18:14:05 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002812349 +- 0.000003202 Vs BL = -0.05624699 +- 0.00006405 Tm Remeasure 18:14:05 Integrated Voltage Measurement... 18:14:06 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:14:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002835852 Vs 18:14:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002803261 Vs 18:14:22 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:14:29 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002839087 Vs 18:14:37 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809200 Vs 18:14:38 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:14:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002813551 Vs 18:14:53 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002806197 Vs 18:14:54 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:15:01 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002809531 Vs 18:15:09 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002808137 Vs 18:15:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815602 +- 0.000006466 Vs 18:15:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002815602 +- 0.000006466 Vs BL = -0.05631204 +- 0.00012931 Tm Remeasure 18:15:09 Integrated Voltage Measurement... 18:15:10 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:15:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002819502 Vs 18:15:25 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002810232 Vs 18:15:26 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:15:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002815660 Vs 18:15:41 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002812436 Vs 18:15:42 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:15:49 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002835694 Vs 18:15:57 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002809247 Vs 18:15:58 Magnet Current for MAIN, Imag = 154.9851 A Vtrans = 1.549908 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:16:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002818522 Vs 18:16:13 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0050000 m VT = 0.002807434 Vs 18:16:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0050000 m VT = -0.002816091 +- 0.000003744 Vs 18:16:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002816091 +- 0.000003744 Vs BL = -0.05632182 +- 0.00007487 Tm 18:16:13 Integrated Voltage Measurement... 18:16:14 Magnet Current for MAIN, Imag = 154.9861 A Vtrans = 1.549918 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:16:22 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665288 Vs 18:16:30 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645022 Vs 18:16:31 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:16:38 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664213 Vs 18:16:46 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002655686 Vs 18:16:47 Magnet Current for MAIN, Imag = 154.9859 A Vtrans = 1.549917 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:16:54 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663905 Vs 18:17:02 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002657856 Vs 18:17:03 Magnet Current for MAIN, Imag = 154.9857 A Vtrans = 1.549914 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:17:10 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664316 Vs 18:17:18 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002641863 Vs 18:17:18 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657269 +- 0.000003247 Vs 18:17:18 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657269 +- 0.000003247 Vs BL = -0.05314537 +- 0.00006493 Tm Remeasure 18:17:18 Integrated Voltage Measurement... 18:17:19 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:17:26 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664568 Vs 18:17:34 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002651538 Vs 18:17:34 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:17:42 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002659981 Vs 18:17:50 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002639351 Vs 18:17:50 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:17:58 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002656622 Vs 18:18:06 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002644444 Vs 18:18:06 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:18:14 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002667108 Vs 18:18:22 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002646840 Vs 18:18:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002653806 +- 0.000003739 Vs 18:18:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002653806 +- 0.000003739 Vs BL = -0.05307613 +- 0.00007478 Tm Remeasure 18:18:22 Integrated Voltage Measurement... 18:18:22 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:18:30 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002668355 Vs 18:18:38 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002649187 Vs 18:18:38 Magnet Current for MAIN, Imag = 154.9852 A Vtrans = 1.549909 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:18:46 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002666128 Vs 18:18:54 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002640693 Vs 18:18:54 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:19:02 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665690 Vs 18:19:10 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002653147 Vs 18:19:10 Magnet Current for MAIN, Imag = 154.9849 A Vtrans = 1.549907 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:19:18 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002668298 Vs 18:19:26 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647717 Vs 18:19:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002657402 +- 0.000002358 Vs 18:19:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002657402 +- 0.000002358 Vs BL = -0.05314804 +- 0.00004716 Tm Remeasure 18:19:26 Integrated Voltage Measurement... 18:19:26 Magnet Current for MAIN, Imag = 154.9848 A Vtrans = 1.549905 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:19:34 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002666100 Vs 18:19:42 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002651608 Vs 18:19:42 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:19:50 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665314 Vs 18:19:58 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002648231 Vs 18:19:58 Magnet Current for MAIN, Imag = 154.9856 A Vtrans = 1.549913 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:20:06 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665448 Vs 18:20:13 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002658310 Vs 18:20:14 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:20:22 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002667447 Vs 18:20:30 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002647040 Vs 18:20:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002658687 +- 0.000001998 Vs 18:20:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002658687 +- 0.000001998 Vs BL = -0.05317374 +- 0.00003996 Tm Remeasure 18:20:30 Integrated Voltage Measurement... 18:20:30 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:20:38 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002664738 Vs 18:20:45 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002644940 Vs 18:20:46 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:20:54 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002660613 Vs 18:21:01 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002650931 Vs 18:21:02 Magnet Current for MAIN, Imag = 154.9853 A Vtrans = 1.549910 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:21:10 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002665024 Vs 18:21:17 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002650482 Vs 18:21:18 Magnet Current for MAIN, Imag = 154.9854 A Vtrans = 1.549912 V, Factor V/A = 0.010000 V/A, Zero Current = 0.005733 A 18:21:26 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002663725 Vs 18:21:33 Integrated Voltage Measurement X0 = 0.0350000 m, Delta X = -0.0050000 m VT = 0.002645138 Vs 18:21:33 Integrated Voltage Average and RMS of Measurements X0 = 0.0350000 m, Delta X = 0.0050000 m VT = -0.002655699 +- 0.000001282 Vs 18:21:33 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0350000 m, dx = 0.0050000 m, Nturns = 10.0 VT = -0.002655699 +- 0.000001282 Vs BL = -0.05311398 +- 0.00002563 Tm 18:21:37 Position moved: 0.000000 m 18:21:40 Position moved: 0.000000 m 18:21:43 Magnet system MAIN current ramping to 0.0000 A...