SLAC Magnetic Measurements Date: 02-21-2018 Time: 17:13:07 Project: FACET_II Magnet Type: Dipole Magnet Name: 1.182D6.82T-1 Serial Number: 1 Run Number: 1 Measurement Device: 10wire Operator: sda Comment: Integrated field measurement at 300 A for coil calibration. Standardization for BEND: 15 cycles from 0.0 A to 300.0 A to 0.0 A Test Currents for BEND (A): 100.00 200.00 300.00 300.00 17:13:47 Position moved: 0.000000 m 17:14:39 Magnet Current for BEND, Imag = -0.0079 A Vtrans = -0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:14:40 Magnet Current for BEND, Imag = -0.0079 A Vtrans = -0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:14:41 Magnet Current for BEND, Imag = -0.0079 A Vtrans = -0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:14:41 Magnet Current for BEND, Imag = -0.0079 A Vtrans = -0.000079 V, Factor V/A = 0.010000 V/A, Zero Current = 0.000000 A 17:14:42 Magnet Avgerage Current Measurement for BEND : Imag = -0.0079 +- 0.0000 A 17:15:08 Initial Zero Current Measurement for BEND, Imag_zero = -0.00788493 A 17:15:08 Ambient Measurement Device(s) Being Used, type = None 17:15:08 Magnet Voltage Measurement Device(s) Being Used, type = HP34970 17:15:09 Temperature Measurement Device(s) Being Used, type = HPTHERM_HP34970 17:15:09 XMAG Device(s) Being Used, type = None 17:15:09 Ambient Measurement Device(s) Being Used, type = HP34970 17:15:09 Magnet system BEND current ramping to 300.0000 A... 18:16:44 Magnet Current for BEND, Imag = 300.0073 A Vtrans = 2.999994 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 18:16:45 MAIN (V) Voltage Measurement, V = 0.000008 V 18:16:45 Temperature Measurement, Probe Number = 0, T = 30.526000 C 18:16:46 Temperature Measurement, Probe Number = 1, T = 20.833000 C 18:16:47 Temperature Measurement, Probe Number = 2, T = 17.949000 C 18:16:47 Sensor Voltage Measurement, Sensor Number = 0, V = 2.251698 V 18:16:47 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.251698 (V, A, ohm, ...), Measured Value = 27.384688 (C, atm, Hz, ...) 18:16:48 Sensor Voltage Measurement, Sensor Number = 1, V = 2.919780 V 18:16:48 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.919780 (V, A, ohm, ...), Measured Value = 36.663611 (C, atm, Hz, ...) 18:16:49 Sensor Voltage Measurement, Sensor Number = 2, V = 2.678267 V 18:16:49 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.678267 (V, A, ohm, ...), Measured Value = 125.870002 (C, atm, Hz, ...) 18:16:49 Sensor Voltage Measurement, Sensor Number = 3, V = 1.089989 V 18:16:49 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.089989 (V, A, ohm, ...), Measured Value = 6.749160 (C, atm, Hz, ...) 18:16:49 Magnet Test Parameter Measurements P0 = BEND, Value = 300.01 P1 = MAIN (V), Value = 0.00 P2 = Coil (C), Value = 30.53 P3 = Steel (C), Value = 20.83 P4 = Ambient Temp (C), Value = 17.95 P5 = Supply Temp(C), Value = 27.38 P6 = Return Temp(C), Value = 36.66 P7 = Supply Pres(psi), Value = 125.87 P8 = Return Pres(psi), Value = 6.75 18:16:50 Magnet system BEND current ramping to 0.0000 A... 18:18:24 Magnet system BEND current ramping to 300.0000 A... 18:19:58 Magnet system BEND current ramping to 0.0000 A... 18:21:32 Magnet system BEND current ramping to 300.0000 A... 18:23:07 Magnet system BEND current ramping to 0.0000 A... 18:24:41 Magnet system BEND current ramping to 300.0000 A... 18:26:15 Magnet system BEND current ramping to 0.0000 A... 18:27:50 Magnet system BEND current ramping to 300.0000 A... 18:29:24 Magnet system BEND current ramping to 0.0000 A... 18:30:58 Magnet system BEND current ramping to 300.0000 A... 18:32:33 Magnet system BEND current ramping to 0.0000 A... 18:34:07 Magnet system BEND current ramping to 300.0000 A... 18:35:41 Magnet system BEND current ramping to 0.0000 A... 18:37:16 Magnet system BEND current ramping to 300.0000 A... 18:38:50 Magnet system BEND current ramping to 0.0000 A... 18:40:24 Magnet system BEND current ramping to 300.0000 A... 18:41:59 Magnet system BEND current ramping to 0.0000 A... 18:43:33 Magnet system BEND current ramping to 300.0000 A... 18:45:07 Magnet system BEND current ramping to 0.0000 A... 18:46:42 Magnet system BEND current ramping to 300.0000 A... 18:48:16 Magnet system BEND current ramping to 0.0000 A... 18:49:50 Magnet system BEND current ramping to 300.0000 A... 18:51:25 Magnet system BEND current ramping to 0.0000 A... 18:52:59 Magnet system BEND current ramping to 300.0000 A... 18:54:33 Magnet system BEND current ramping to 0.0000 A... 18:56:08 Magnet system BEND current ramping to 300.0000 A... 18:57:42 Magnet system BEND current ramping to 0.0000 A... 18:59:16 Magnet system BEND current ramping to 300.0000 A... 19:00:51 Magnet system BEND current ramping to 0.0000 A... 19:02:25 Magnet system BEND current ramping to 300.0000 A... 19:03:59 Magnet system BEND current ramping to 0.0000 A... 19:05:36 Position moved: 0.000000 m 19:05:39 Magnet system BEND current ramping to 100.0000 A... 19:06:18 Magnet Current for BEND, Imag = 99.9587 A Vtrans = 0.999508 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:06:19 MAIN (V) Voltage Measurement, V = 0.001409 V 19:06:19 Temperature Measurement, Probe Number = 0, T = 27.135000 C 19:06:20 Temperature Measurement, Probe Number = 1, T = 21.232000 C 19:06:21 Temperature Measurement, Probe Number = 2, T = 17.344000 C 19:06:21 Sensor Voltage Measurement, Sensor Number = 0, V = 2.245057 V 19:06:21 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.245057 (V, A, ohm, ...), Measured Value = 27.292464 (C, atm, Hz, ...) 19:06:22 Sensor Voltage Measurement, Sensor Number = 1, V = 2.476285 V 19:06:22 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.476285 (V, A, ohm, ...), Measured Value = 30.503960 (C, atm, Hz, ...) 19:06:22 Sensor Voltage Measurement, Sensor Number = 2, V = 2.679139 V 19:06:22 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.679139 (V, A, ohm, ...), Measured Value = 125.935395 (C, atm, Hz, ...) 19:06:23 Sensor Voltage Measurement, Sensor Number = 3, V = 1.087115 V 19:06:23 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.087115 (V, A, ohm, ...), Measured Value = 6.533618 (C, atm, Hz, ...) 19:06:23 Magnet Test Parameter Measurements P0 = BEND, Value = 99.96 P1 = MAIN (V), Value = 0.00 P2 = Coil (C), Value = 27.14 P3 = Steel (C), Value = 21.23 P4 = Ambient Temp (C), Value = 17.34 P5 = Supply Temp(C), Value = 27.29 P6 = Return Temp(C), Value = 30.50 P7 = Supply Pres(psi), Value = 125.94 P8 = Return Pres(psi), Value = 6.53 19:06:23 Magnetic Field Measurement Measuring the magnet strength... 19:06:23 Integrated Voltage Measurement... 19:06:24 Magnet Current for BEND, Imag = 99.9589 A Vtrans = 0.999510 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:06:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.011543656 Vs 19:06:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.011520403 Vs 19:06:40 Magnet Current for BEND, Imag = 99.9590 A Vtrans = 0.999511 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:06:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.011545633 Vs 19:06:55 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.011515862 Vs 19:06:56 Magnet Current for BEND, Imag = 99.9591 A Vtrans = 0.999512 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:07:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.011545698 Vs 19:07:10 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.011517229 Vs 19:07:11 Magnet Current for BEND, Imag = 99.9589 A Vtrans = 0.999511 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:07:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.011546997 Vs 19:07:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.011521925 Vs 19:07:26 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.011532175 +- 0.000001396 Vs 19:07:26 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0180000 m, Nturns = 10.0 VT = 0.011532175 +- 0.000001396 Vs BL = 0.06406764 +- 0.00000775 Tm 19:07:30 Position moved: 0.000000 m 19:07:30 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.06407 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.06407 0.00001 0.06407 0.00000 19:07:30 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.06407 0.00001 SL = 0.0640676 +- 0.0000078 Tm^2/m^n 19:07:30 Magnet Strength Measurement Harmonic Number = 1 SL = 0.0640676 +- 0.0000078 Tm^2/m^n 19:07:33 Position moved: 0.000000 m 19:07:33 Magnet system BEND current ramping to 200.0000 A... 19:08:12 Magnet Current for BEND, Imag = 200.0363 A Vtrans = 2.000284 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:08:12 MAIN (V) Voltage Measurement, V = 0.002190 V 19:08:13 Temperature Measurement, Probe Number = 0, T = 26.440000 C 19:08:14 Temperature Measurement, Probe Number = 1, T = 21.245000 C 19:08:14 Temperature Measurement, Probe Number = 2, T = 17.351000 C 19:08:15 Sensor Voltage Measurement, Sensor Number = 0, V = 2.244571 V 19:08:15 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.244571 (V, A, ohm, ...), Measured Value = 27.285703 (C, atm, Hz, ...) 19:08:16 Sensor Voltage Measurement, Sensor Number = 1, V = 2.465691 V 19:08:16 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.465691 (V, A, ohm, ...), Measured Value = 30.356815 (C, atm, Hz, ...) 19:08:16 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665665 V 19:08:16 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665665 (V, A, ohm, ...), Measured Value = 124.924890 (C, atm, Hz, ...) 19:08:17 Sensor Voltage Measurement, Sensor Number = 3, V = 1.086637 V 19:08:17 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.086637 (V, A, ohm, ...), Measured Value = 6.497775 (C, atm, Hz, ...) 19:08:17 Magnet Test Parameter Measurements P0 = BEND, Value = 200.04 P1 = MAIN (V), Value = 0.00 P2 = Coil (C), Value = 26.44 P3 = Steel (C), Value = 21.25 P4 = Ambient Temp (C), Value = 17.35 P5 = Supply Temp(C), Value = 27.29 P6 = Return Temp(C), Value = 30.36 P7 = Supply Pres(psi), Value = 124.92 P8 = Return Pres(psi), Value = 6.50 19:08:17 Magnetic Field Measurement Measuring the magnet strength... 19:08:17 Integrated Voltage Measurement... 19:08:18 Magnet Current for BEND, Imag = 200.0368 A Vtrans = 2.000289 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:08:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.023070540 Vs 19:08:33 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.023036793 Vs 19:08:34 Magnet Current for BEND, Imag = 200.0374 A Vtrans = 2.000295 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:08:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.023063980 Vs 19:08:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.023050512 Vs 19:08:50 Magnet Current for BEND, Imag = 200.0378 A Vtrans = 2.000299 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:08:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.023064544 Vs 19:09:04 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.023037834 Vs 19:09:05 Magnet Current for BEND, Imag = 200.0383 A Vtrans = 2.000304 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:09:12 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.023065466 Vs 19:09:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.023040044 Vs 19:09:20 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.023053714 +- 0.000002223 Vs 19:09:20 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0180000 m, Nturns = 10.0 VT = 0.023053714 +- 0.000002223 Vs BL = 0.12807619 +- 0.00001235 Tm 19:09:24 Position moved: 0.000000 m 19:09:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.12808 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.12808 0.00001 0.12808 0.00000 19:09:24 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.12808 0.00001 SL = 0.1280762 +- 0.0000124 Tm^2/m^n 19:09:24 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1280762 +- 0.0000124 Tm^2/m^n 19:09:27 Position moved: 0.000000 m 19:09:27 Magnet system BEND current ramping to 300.0000 A... 19:10:06 Magnet Current for BEND, Imag = 299.9971 A Vtrans = 2.999892 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:10:06 MAIN (V) Voltage Measurement, V = 0.000172 V 19:10:07 Temperature Measurement, Probe Number = 0, T = 26.893000 C 19:10:07 Temperature Measurement, Probe Number = 1, T = 21.257000 C 19:10:08 Temperature Measurement, Probe Number = 2, T = 17.375000 C 19:10:09 Sensor Voltage Measurement, Sensor Number = 0, V = 2.243270 V 19:10:09 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.243270 (V, A, ohm, ...), Measured Value = 27.267643 (C, atm, Hz, ...) 19:10:09 Sensor Voltage Measurement, Sensor Number = 1, V = 2.416692 V 19:10:09 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.416692 (V, A, ohm, ...), Measured Value = 29.676279 (C, atm, Hz, ...) 19:10:10 Sensor Voltage Measurement, Sensor Number = 2, V = 2.664604 V 19:10:10 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.664604 (V, A, ohm, ...), Measured Value = 124.845292 (C, atm, Hz, ...) 19:10:11 Sensor Voltage Measurement, Sensor Number = 3, V = 1.086964 V 19:10:11 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.086964 (V, A, ohm, ...), Measured Value = 6.522270 (C, atm, Hz, ...) 19:10:11 Magnet Test Parameter Measurements P0 = BEND, Value = 300.00 P1 = MAIN (V), Value = 0.00 P2 = Coil (C), Value = 26.89 P3 = Steel (C), Value = 21.26 P4 = Ambient Temp (C), Value = 17.38 P5 = Supply Temp(C), Value = 27.27 P6 = Return Temp(C), Value = 29.68 P7 = Supply Pres(psi), Value = 124.85 P8 = Return Pres(psi), Value = 6.52 19:10:11 Magnetic Field Measurement Measuring the magnet strength... 19:10:11 Integrated Voltage Measurement... 19:10:11 Magnet Current for BEND, Imag = 299.9976 A Vtrans = 2.999897 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:10:20 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034260140 Vs 19:10:27 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034247177 Vs 19:10:28 Magnet Current for BEND, Imag = 299.9988 A Vtrans = 2.999909 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:10:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034267808 Vs 19:10:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034243045 Vs 19:10:43 Magnet Current for BEND, Imag = 299.9990 A Vtrans = 2.999912 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:10:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034265166 Vs 19:10:58 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034248455 Vs 19:10:58 Magnet Current for BEND, Imag = 300.0008 A Vtrans = 2.999929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:11:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034264565 Vs 19:11:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034241096 Vs 19:11:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034254682 +- 0.000001546 Vs 19:11:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0180000 m, Nturns = 10.0 VT = 0.034254682 +- 0.000001546 Vs BL = 0.19030379 +- 0.00000859 Tm 19:11:17 Position moved: 0.000000 m 19:11:17 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.19030 0.00001 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.19030 0.00001 0.19030 0.00000 19:11:17 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.19030 0.00001 SL = 0.1903038 +- 0.0000086 Tm^2/m^n 19:11:17 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1903038 +- 0.0000086 Tm^2/m^n 19:11:20 Position moved: 0.000000 m 19:11:20 Magnet system BEND current ramping to 300.0000 A... 19:11:31 Magnet Current for BEND, Imag = 300.0012 A Vtrans = 2.999933 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:11:32 MAIN (V) Voltage Measurement, V = 0.000132 V 19:11:32 Temperature Measurement, Probe Number = 0, T = 28.161000 C 19:11:33 Temperature Measurement, Probe Number = 1, T = 21.261000 C 19:11:34 Temperature Measurement, Probe Number = 2, T = 17.405000 C 19:11:34 Sensor Voltage Measurement, Sensor Number = 0, V = 2.243564 V 19:11:34 Sensor Measurement, Sensor Number = 0, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.243564 (V, A, ohm, ...), Measured Value = 27.271721 (C, atm, Hz, ...) 19:11:35 Sensor Voltage Measurement, Sensor Number = 1, V = 2.401969 V 19:11:35 Sensor Measurement, Sensor Number = 1, Sensor Type = WATER_HPLEIGHTON_T Raw Sensor Output = 2.401969 (V, A, ohm, ...), Measured Value = 29.471792 (C, atm, Hz, ...) 19:11:36 Sensor Voltage Measurement, Sensor Number = 2, V = 2.665539 V 19:11:36 Sensor Measurement, Sensor Number = 2, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 2.665539 (V, A, ohm, ...), Measured Value = 124.915455 (C, atm, Hz, ...) 19:11:36 Sensor Voltage Measurement, Sensor Number = 3, V = 1.086761 V 19:11:36 Sensor Measurement, Sensor Number = 3, Sensor Type = WATER_HPASHCROFT_P Raw Sensor Output = 1.086761 (V, A, ohm, ...), Measured Value = 6.507112 (C, atm, Hz, ...) 19:11:36 Magnet Test Parameter Measurements P0 = BEND, Value = 300.00 P1 = MAIN (V), Value = 0.00 P2 = Coil (C), Value = 28.16 P3 = Steel (C), Value = 21.26 P4 = Ambient Temp (C), Value = 17.41 P5 = Supply Temp(C), Value = 27.27 P6 = Return Temp(C), Value = 29.47 P7 = Supply Pres(psi), Value = 124.92 P8 = Return Pres(psi), Value = 6.51 19:11:36 Magnetic Field Measurement Measuring the magnet strength... 19:11:36 Integrated Voltage Measurement... 19:11:37 Magnet Current for BEND, Imag = 300.0016 A Vtrans = 2.999937 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:11:45 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034268120 Vs 19:11:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034239664 Vs 19:11:53 Magnet Current for BEND, Imag = 300.0006 A Vtrans = 2.999927 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:12:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034266246 Vs 19:12:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034252308 Vs 19:12:09 Magnet Current for BEND, Imag = 300.0008 A Vtrans = 2.999929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:12:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034264198 Vs 19:12:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034246040 Vs 19:12:24 Magnet Current for BEND, Imag = 300.0008 A Vtrans = 2.999929 V, Factor V/A = 0.010000 V/A, Zero Current = -0.007885 A 19:12:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034265745 Vs 19:12:39 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0180000 m VT = -0.034222758 Vs 19:12:39 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0180000 m VT = 0.034253135 +- 0.000005503 Vs 19:12:39 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0180000 m, Nturns = 10.0 VT = 0.034253135 +- 0.000005503 Vs BL = 0.19029519 +- 0.00003057 Tm 19:12:43 Position moved: 0.000000 m 19:12:43 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.19030 0.00003 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- 0.0000000 0.19030 0.00003 0.19030 0.00000 19:12:43 Magnet Strength Calculation Harmonic Number = 1 Number Of X0 Positions = 1 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- 0.0000 0.19030 0.00003 SL = 0.1902952 +- 0.0000306 Tm^2/m^n 19:12:43 Magnet Strength Measurement Harmonic Number = 1 SL = 0.1902952 +- 0.0000306 Tm^2/m^n 19:12:46 Position moved: 0.000000 m 19:12:49 Position moved: 0.000000 m 19:12:51 Magnet system BEND current ramping to 0.0000 A...