SLAC Magnetic Measurements Date: 09-24-2008 Time: 16:11:48 Project: E163 Magnet Type: quad Magnet Name: PMQ3 Serial Number: 3 Run Number: 18 Measurement Device: 1 wire Operator: sda Comment: BL vx x, Slight decrease to measurement range. Test Currents (A): 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 16:13:01 Name = None, is zeroed 16:13:01 Integrated Voltage Measurement... 16:13:09 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001336 V 16:13:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002441 Vs 16:13:17 Voltage Offset Correction: v_off_ini = -0.000001250 V, v_off_fin = -0.000001260 V 16:13:17 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002410 Vs 16:13:26 Voltage Offset Correction: v_off_ini = -0.000001284 V, v_off_fin = -0.000001265 V 16:13:26 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002406 Vs 16:13:35 Voltage Offset Correction: v_off_ini = -0.000001250 V, v_off_fin = -0.000001268 V 16:13:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002426 Vs 16:13:45 Voltage Offset Correction: v_off_ini = -0.000001337 V, v_off_fin = -0.000001362 V 16:13:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002434 Vs 16:13:53 Voltage Offset Correction: v_off_ini = -0.000001150 V, v_off_fin = -0.000001197 V 16:13:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002407 Vs 16:14:02 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001193 V 16:14:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002478 Vs 16:14:10 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000001120 V 16:14:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002500 Vs 16:14:18 Voltage Offset Correction: v_off_ini = -0.000001291 V, v_off_fin = -0.000001269 V 16:14:18 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002356 Vs 16:14:27 Voltage Offset Correction: v_off_ini = -0.000001179 V, v_off_fin = -0.000001325 V 16:14:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002386 Vs 16:14:35 Voltage Offset Correction: v_off_ini = -0.000001464 V, v_off_fin = -0.000001077 V 16:14:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002395 Vs 16:14:43 Voltage Offset Correction: v_off_ini = -0.000001531 V, v_off_fin = -0.000001573 V 16:14:43 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002473 Vs 16:14:52 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = -0.000001330 V 16:14:52 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002443 Vs 16:15:00 Voltage Offset Correction: v_off_ini = -0.000001240 V, v_off_fin = -0.000001040 V 16:15:00 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002428 Vs 16:15:08 Voltage Offset Correction: v_off_ini = -0.000001298 V, v_off_fin = -0.000000980 V 16:15:08 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002473 Vs 16:15:17 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000001266 V 16:15:17 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002520 Vs 16:15:17 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002436 +- 0.000000038 Vs 16:15:17 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002436 +- 0.000000038 Vs BL = 0.00487199 +- 0.00007594 Tm 16:15:17 Integrated Voltage Measurement... 16:15:25 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001204 V 16:15:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001446 Vs 16:15:34 Voltage Offset Correction: v_off_ini = -0.000001135 V, v_off_fin = -0.000001185 V 16:15:34 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001124 Vs 16:15:42 Voltage Offset Correction: v_off_ini = -0.000001133 V, v_off_fin = -0.000001022 V 16:15:42 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001295 Vs 16:15:50 Voltage Offset Correction: v_off_ini = -0.000001370 V, v_off_fin = -0.000001259 V 16:15:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001276 Vs 16:15:59 Voltage Offset Correction: v_off_ini = -0.000001466 V, v_off_fin = -0.000001397 V 16:15:59 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001223 Vs 16:16:07 Voltage Offset Correction: v_off_ini = -0.000001150 V, v_off_fin = -0.000001731 V 16:16:07 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001076 Vs 16:16:15 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001504 V 16:16:15 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001313 Vs 16:16:24 Voltage Offset Correction: v_off_ini = -0.000001425 V, v_off_fin = -0.000001555 V 16:16:24 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001315 Vs 16:16:32 Voltage Offset Correction: v_off_ini = -0.000001160 V, v_off_fin = -0.000001267 V 16:16:32 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001242 Vs 16:16:40 Voltage Offset Correction: v_off_ini = -0.000001374 V, v_off_fin = -0.000001475 V 16:16:40 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001305 Vs 16:16:49 Voltage Offset Correction: v_off_ini = -0.000001202 V, v_off_fin = -0.000001118 V 16:16:49 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001245 Vs 16:16:57 Voltage Offset Correction: v_off_ini = -0.000001363 V, v_off_fin = -0.000001629 V 16:16:57 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001140 Vs 16:17:05 Voltage Offset Correction: v_off_ini = -0.000001590 V, v_off_fin = -0.000001457 V 16:17:05 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001225 Vs 16:17:14 Voltage Offset Correction: v_off_ini = -0.000001298 V, v_off_fin = -0.000001229 V 16:17:14 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001172 Vs 16:17:22 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000001427 V 16:17:22 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001347 Vs 16:17:30 Voltage Offset Correction: v_off_ini = -0.000001217 V, v_off_fin = -0.000001321 V 16:17:30 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001243 Vs 16:17:30 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001249 +- 0.000000056 Vs 16:17:30 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001249 +- 0.000000056 Vs BL = 0.00249848 +- 0.00011241 Tm 16:17:31 Integrated Voltage Measurement... 16:17:43 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000001452 V 16:17:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000051 Vs 16:17:51 Voltage Offset Correction: v_off_ini = -0.000001149 V, v_off_fin = -0.000001171 V 16:17:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000059 Vs 16:18:00 Voltage Offset Correction: v_off_ini = -0.000001308 V, v_off_fin = -0.000001340 V 16:18:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000052 Vs 16:18:08 Voltage Offset Correction: v_off_ini = -0.000001686 V, v_off_fin = -0.000001629 V 16:18:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000011 Vs 16:18:17 Voltage Offset Correction: v_off_ini = -0.000001370 V, v_off_fin = -0.000001296 V 16:18:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000022 Vs 16:18:25 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000001348 V 16:18:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000108 Vs 16:18:34 Voltage Offset Correction: v_off_ini = -0.000001199 V, v_off_fin = -0.000001256 V 16:18:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = -0.000000034 Vs 16:18:42 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001234 V 16:18:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000034 Vs 16:18:50 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000001183 V 16:18:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000294 Vs 16:18:59 Voltage Offset Correction: v_off_ini = -0.000001459 V, v_off_fin = -0.000001510 V 16:18:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000039 Vs 16:19:07 Voltage Offset Correction: v_off_ini = -0.000001424 V, v_off_fin = -0.000001622 V 16:19:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000027 Vs 16:19:16 Voltage Offset Correction: v_off_ini = -0.000001341 V, v_off_fin = -0.000001325 V 16:19:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000031 Vs 16:19:24 Voltage Offset Correction: v_off_ini = -0.000001238 V, v_off_fin = -0.000001454 V 16:19:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000081 Vs 16:19:32 Voltage Offset Correction: v_off_ini = -0.000001355 V, v_off_fin = -0.000001228 V 16:19:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000140 Vs 16:19:41 Voltage Offset Correction: v_off_ini = -0.000001567 V, v_off_fin = -0.000001551 V 16:19:41 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000110 Vs 16:19:49 Voltage Offset Correction: v_off_ini = -0.000001465 V, v_off_fin = -0.000001523 V 16:19:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000095 Vs 16:19:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000069 +- 0.000000052 Vs 16:19:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000069 +- 0.000000052 Vs BL = 0.00013714 +- 0.00010313 Tm 16:19:49 Integrated Voltage Measurement... 16:19:58 Voltage Offset Correction: v_off_ini = -0.000001373 V, v_off_fin = -0.000001376 V 16:19:58 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001184 Vs 16:20:06 Voltage Offset Correction: v_off_ini = -0.000001494 V, v_off_fin = -0.000001439 V 16:20:06 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001058 Vs 16:20:14 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000001284 V 16:20:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001008 Vs 16:20:23 Voltage Offset Correction: v_off_ini = -0.000001334 V, v_off_fin = -0.000001428 V 16:20:23 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001058 Vs 16:20:31 Voltage Offset Correction: v_off_ini = -0.000001422 V, v_off_fin = -0.000001519 V 16:20:31 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001157 Vs 16:20:39 Voltage Offset Correction: v_off_ini = -0.000001323 V, v_off_fin = -0.000001096 V 16:20:39 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000928 Vs 16:20:48 Voltage Offset Correction: v_off_ini = -0.000001456 V, v_off_fin = -0.000001445 V 16:20:48 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001099 Vs 16:20:56 Voltage Offset Correction: v_off_ini = -0.000001417 V, v_off_fin = -0.000001910 V 16:20:56 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001007 Vs 16:21:04 Voltage Offset Correction: v_off_ini = -0.000001460 V, v_off_fin = -0.000001421 V 16:21:04 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001163 Vs 16:21:13 Voltage Offset Correction: v_off_ini = -0.000001163 V, v_off_fin = -0.000001176 V 16:21:13 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001044 Vs 16:21:21 Voltage Offset Correction: v_off_ini = -0.000001293 V, v_off_fin = -0.000001217 V 16:21:21 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001205 Vs 16:21:29 Voltage Offset Correction: v_off_ini = -0.000001557 V, v_off_fin = -0.000001703 V 16:21:29 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001036 Vs 16:21:39 Voltage Offset Correction: v_off_ini = -0.000001315 V, v_off_fin = -0.000001294 V 16:21:39 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = 0.000000027 Vs 16:21:48 Voltage Offset Correction: v_off_ini = -0.000001349 V, v_off_fin = -0.000001201 V 16:21:48 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001071 Vs 16:21:56 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000001593 V 16:21:56 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001171 Vs 16:22:04 Voltage Offset Correction: v_off_ini = -0.000001349 V, v_off_fin = -0.000001410 V 16:22:05 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001078 Vs 16:22:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001015 +- 0.000000190 Vs 16:22:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001015 +- 0.000000190 Vs BL = -0.00202992 +- 0.00037952 Tm 16:22:05 Integrated Voltage Measurement... 16:22:13 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000000893 V 16:22:13 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002337 Vs 16:22:21 Voltage Offset Correction: v_off_ini = -0.000001655 V, v_off_fin = -0.000001519 V 16:22:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002267 Vs 16:22:30 Voltage Offset Correction: v_off_ini = -0.000001292 V, v_off_fin = -0.000001218 V 16:22:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002325 Vs 16:22:38 Voltage Offset Correction: v_off_ini = -0.000001030 V, v_off_fin = -0.000001573 V 16:22:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002498 Vs 16:22:46 Voltage Offset Correction: v_off_ini = -0.000001183 V, v_off_fin = -0.000001239 V 16:22:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002283 Vs 16:22:55 Voltage Offset Correction: v_off_ini = -0.000001135 V, v_off_fin = -0.000001011 V 16:22:55 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002291 Vs 16:23:03 Voltage Offset Correction: v_off_ini = -0.000001265 V, v_off_fin = -0.000001228 V 16:23:03 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002290 Vs 16:23:11 Voltage Offset Correction: v_off_ini = -0.000001219 V, v_off_fin = -0.000001307 V 16:23:11 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002320 Vs 16:23:20 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000000818 V 16:23:20 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002268 Vs 16:23:28 Voltage Offset Correction: v_off_ini = -0.000001065 V, v_off_fin = -0.000001281 V 16:23:28 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002099 Vs 16:23:36 Voltage Offset Correction: v_off_ini = -0.000001314 V, v_off_fin = -0.000001273 V 16:23:36 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002216 Vs 16:23:45 Voltage Offset Correction: v_off_ini = -0.000001453 V, v_off_fin = -0.000001510 V 16:23:45 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002315 Vs 16:23:53 Voltage Offset Correction: v_off_ini = -0.000001212 V, v_off_fin = -0.000001302 V 16:23:53 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002314 Vs 16:24:01 Voltage Offset Correction: v_off_ini = -0.000001263 V, v_off_fin = -0.000001203 V 16:24:01 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002266 Vs 16:24:10 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = -0.000001317 V 16:24:10 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002215 Vs 16:24:18 Voltage Offset Correction: v_off_ini = -0.000001042 V, v_off_fin = -0.000000976 V 16:24:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002227 Vs 16:24:18 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002283 +- 0.000000063 Vs 16:24:18 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000002283 +- 0.000000063 Vs BL = -0.00456604 +- 0.00012544 Tm 16:24:20 Integrated Voltage Measurement... 16:24:29 Voltage Offset Correction: v_off_ini = -0.000001147 V, v_off_fin = -0.000001118 V 16:24:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002572 Vs 16:24:37 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001208 V 16:24:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002628 Vs 16:24:45 Voltage Offset Correction: v_off_ini = -0.000001290 V, v_off_fin = -0.000001705 V 16:24:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002622 Vs 16:24:54 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = -0.000001032 V 16:24:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002665 Vs 16:25:02 Voltage Offset Correction: v_off_ini = -0.000001358 V, v_off_fin = -0.000001331 V 16:25:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002566 Vs 16:25:10 Voltage Offset Correction: v_off_ini = -0.000001267 V, v_off_fin = -0.000001122 V 16:25:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002546 Vs 16:25:19 Voltage Offset Correction: v_off_ini = -0.000001340 V, v_off_fin = -0.000001240 V 16:25:19 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002512 Vs 16:25:27 Voltage Offset Correction: v_off_ini = -0.000001180 V, v_off_fin = -0.000000855 V 16:25:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002650 Vs 16:25:38 Voltage Offset Correction: v_off_ini = -0.000001247 V, v_off_fin = -0.000001265 V 16:25:38 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002593 Vs 16:25:46 Voltage Offset Correction: v_off_ini = -0.000001193 V, v_off_fin = -0.000001500 V 16:25:46 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002527 Vs 16:25:54 Voltage Offset Correction: v_off_ini = -0.000001299 V, v_off_fin = -0.000001368 V 16:25:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002654 Vs 16:26:03 Voltage Offset Correction: v_off_ini = -0.000001425 V, v_off_fin = -0.000001254 V 16:26:03 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002550 Vs 16:26:11 Voltage Offset Correction: v_off_ini = -0.000001342 V, v_off_fin = -0.000001279 V 16:26:11 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002622 Vs 16:26:19 Voltage Offset Correction: v_off_ini = -0.000001064 V, v_off_fin = -0.000001362 V 16:26:19 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002679 Vs 16:26:28 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001073 V 16:26:28 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002568 Vs 16:26:36 Voltage Offset Correction: v_off_ini = -0.000001397 V, v_off_fin = -0.000001360 V 16:26:36 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002561 Vs 16:26:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002595 +- 0.000000034 Vs 16:26:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002595 +- 0.000000034 Vs BL = 0.00518909 +- 0.00006858 Tm 16:26:36 Integrated Voltage Measurement... 16:26:44 Voltage Offset Correction: v_off_ini = -0.000001309 V, v_off_fin = -0.000001274 V 16:26:44 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001395 Vs 16:26:53 Voltage Offset Correction: v_off_ini = -0.000001199 V, v_off_fin = -0.000001283 V 16:26:53 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001330 Vs 16:27:01 Voltage Offset Correction: v_off_ini = -0.000001379 V, v_off_fin = -0.000001405 V 16:27:01 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001308 Vs 16:27:10 Voltage Offset Correction: v_off_ini = -0.000001482 V, v_off_fin = -0.000001353 V 16:27:10 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001388 Vs 16:27:18 Voltage Offset Correction: v_off_ini = -0.000001283 V, v_off_fin = -0.000001482 V 16:27:18 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001376 Vs 16:27:26 Voltage Offset Correction: v_off_ini = -0.000001578 V, v_off_fin = -0.000001520 V 16:27:26 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001450 Vs 16:27:35 Voltage Offset Correction: v_off_ini = -0.000001164 V, v_off_fin = -0.000001358 V 16:27:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001267 Vs 16:27:43 Voltage Offset Correction: v_off_ini = -0.000001457 V, v_off_fin = -0.000001517 V 16:27:43 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001377 Vs 16:27:51 Voltage Offset Correction: v_off_ini = -0.000001397 V, v_off_fin = -0.000001282 V 16:27:51 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001403 Vs 16:28:00 Voltage Offset Correction: v_off_ini = -0.000001196 V, v_off_fin = -0.000001059 V 16:28:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001300 Vs 16:28:08 Voltage Offset Correction: v_off_ini = -0.000001252 V, v_off_fin = -0.000001517 V 16:28:08 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001496 Vs 16:28:16 Voltage Offset Correction: v_off_ini = -0.000001492 V, v_off_fin = -0.000001389 V 16:28:16 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001411 Vs 16:28:25 Voltage Offset Correction: v_off_ini = -0.000001253 V, v_off_fin = -0.000001263 V 16:28:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001373 Vs 16:28:33 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001114 V 16:28:33 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001278 Vs 16:28:41 Voltage Offset Correction: v_off_ini = -0.000001394 V, v_off_fin = -0.000001474 V 16:28:42 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001347 Vs 16:28:50 Voltage Offset Correction: v_off_ini = -0.000001234 V, v_off_fin = -0.000001218 V 16:28:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001368 Vs 16:28:50 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001367 +- 0.000000042 Vs 16:28:50 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001367 +- 0.000000042 Vs BL = 0.00273337 +- 0.00008368 Tm 16:28:50 Integrated Voltage Measurement... 16:28:59 Voltage Offset Correction: v_off_ini = -0.000001123 V, v_off_fin = -0.000001087 V 16:28:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000116 Vs 16:29:07 Voltage Offset Correction: v_off_ini = -0.000001444 V, v_off_fin = -0.000001452 V 16:29:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000200 Vs 16:29:16 Voltage Offset Correction: v_off_ini = -0.000001319 V, v_off_fin = -0.000001549 V 16:29:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000087 Vs 16:29:24 Voltage Offset Correction: v_off_ini = -0.000001175 V, v_off_fin = -0.000001151 V 16:29:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000168 Vs 16:29:32 Voltage Offset Correction: v_off_ini = -0.000001396 V, v_off_fin = -0.000001402 V 16:29:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000146 Vs 16:29:43 Voltage Offset Correction: v_off_ini = -0.000001233 V, v_off_fin = -0.000001134 V 16:29:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000216 Vs 16:29:52 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000000995 V 16:29:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000125 Vs 16:30:00 Voltage Offset Correction: v_off_ini = -0.000001326 V, v_off_fin = -0.000001292 V 16:30:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000071 Vs 16:30:08 Voltage Offset Correction: v_off_ini = -0.000001186 V, v_off_fin = -0.000001083 V 16:30:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000087 Vs 16:30:17 Voltage Offset Correction: v_off_ini = -0.000001247 V, v_off_fin = -0.000001228 V 16:30:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000094 Vs 16:30:25 Voltage Offset Correction: v_off_ini = -0.000001491 V, v_off_fin = -0.000001473 V 16:30:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000183 Vs 16:30:34 Voltage Offset Correction: v_off_ini = -0.000001330 V, v_off_fin = -0.000001393 V 16:30:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000171 Vs 16:30:42 Voltage Offset Correction: v_off_ini = -0.000001220 V, v_off_fin = -0.000001237 V 16:30:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000193 Vs 16:30:50 Voltage Offset Correction: v_off_ini = -0.000001232 V, v_off_fin = -0.000001283 V 16:30:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000072 Vs 16:30:59 Voltage Offset Correction: v_off_ini = -0.000001075 V, v_off_fin = -0.000001240 V 16:30:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000157 Vs 16:31:07 Voltage Offset Correction: v_off_ini = -0.000001440 V, v_off_fin = -0.000001534 V 16:31:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000188 Vs 16:31:07 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000142 +- 0.000000033 Vs 16:31:07 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000142 +- 0.000000033 Vs BL = 0.00028427 +- 0.00006632 Tm 16:31:07 Integrated Voltage Measurement... 16:31:16 Voltage Offset Correction: v_off_ini = -0.000001074 V, v_off_fin = -0.000001268 V 16:31:16 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000001009 Vs 16:31:24 Voltage Offset Correction: v_off_ini = -0.000001387 V, v_off_fin = -0.000001319 V 16:31:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000984 Vs 16:31:32 Voltage Offset Correction: v_off_ini = -0.000001440 V, v_off_fin = -0.000001409 V 16:31:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000938 Vs 16:31:41 Voltage Offset Correction: v_off_ini = -0.000001362 V, v_off_fin = -0.000001455 V 16:31:41 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001111 Vs 16:31:49 Voltage Offset Correction: v_off_ini = -0.000001532 V, v_off_fin = -0.000001372 V 16:31:49 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000934 Vs 16:31:57 Voltage Offset Correction: v_off_ini = -0.000001330 V, v_off_fin = -0.000001264 V 16:31:57 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000965 Vs 16:32:06 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000001229 V 16:32:06 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000952 Vs 16:32:14 Voltage Offset Correction: v_off_ini = -0.000001561 V, v_off_fin = -0.000001401 V 16:32:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000964 Vs 16:32:22 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000000939 V 16:32:22 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000969 Vs 16:32:31 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = -0.000001328 V 16:32:31 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000872 Vs 16:32:39 Voltage Offset Correction: v_off_ini = -0.000001301 V, v_off_fin = -0.000001378 V 16:32:39 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000862 Vs 16:32:47 Voltage Offset Correction: v_off_ini = -0.000001073 V, v_off_fin = -0.000000688 V 16:32:48 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000977 Vs 16:32:56 Voltage Offset Correction: v_off_ini = -0.000001410 V, v_off_fin = -0.000001389 V 16:32:56 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000974 Vs 16:33:04 Voltage Offset Correction: v_off_ini = -0.000001316 V, v_off_fin = -0.000001057 V 16:33:04 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000682 Vs 16:33:13 Voltage Offset Correction: v_off_ini = -0.000001158 V, v_off_fin = -0.000001165 V 16:33:13 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000942 Vs 16:33:21 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001394 V 16:33:21 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000969 Vs 16:33:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000944 +- 0.000000055 Vs 16:33:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000944 +- 0.000000055 Vs BL = -0.00188804 +- 0.00011020 Tm 16:33:21 Integrated Voltage Measurement... 16:33:29 Voltage Offset Correction: v_off_ini = -0.000001301 V, v_off_fin = -0.000001203 V 16:33:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002043 Vs 16:33:41 Voltage Offset Correction: v_off_ini = -0.000001219 V, v_off_fin = -0.000001679 V 16:33:41 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = -0.000000031 Vs 16:33:50 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000001080 V 16:33:50 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002189 Vs 16:33:58 Voltage Offset Correction: v_off_ini = -0.000001240 V, v_off_fin = -0.000001135 V 16:33:58 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002111 Vs 16:34:06 Voltage Offset Correction: v_off_ini = -0.000001194 V, v_off_fin = -0.000001141 V 16:34:06 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002126 Vs 16:34:15 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001399 V 16:34:15 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002195 Vs 16:34:23 Voltage Offset Correction: v_off_ini = -0.000001355 V, v_off_fin = -0.000001201 V 16:34:23 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002167 Vs 16:34:31 Voltage Offset Correction: v_off_ini = -0.000001187 V, v_off_fin = -0.000001309 V 16:34:31 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002182 Vs 16:34:40 Voltage Offset Correction: v_off_ini = -0.000001202 V, v_off_fin = -0.000001298 V 16:34:40 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002147 Vs 16:34:48 Voltage Offset Correction: v_off_ini = -0.000001308 V, v_off_fin = -0.000001377 V 16:34:48 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002058 Vs 16:34:56 Voltage Offset Correction: v_off_ini = -0.000001252 V, v_off_fin = -0.000001354 V 16:34:56 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002208 Vs 16:35:05 Voltage Offset Correction: v_off_ini = -0.000001408 V, v_off_fin = -0.000000991 V 16:35:05 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002077 Vs 16:35:13 Voltage Offset Correction: v_off_ini = -0.000001444 V, v_off_fin = -0.000001338 V 16:35:13 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002180 Vs 16:35:21 Voltage Offset Correction: v_off_ini = -0.000001394 V, v_off_fin = -0.000001357 V 16:35:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002053 Vs 16:35:30 Voltage Offset Correction: v_off_ini = -0.000001099 V, v_off_fin = -0.000000469 V 16:35:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001841 Vs 16:35:38 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = -0.000001462 V 16:35:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002152 Vs 16:35:38 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001981 +- 0.000000372 Vs 16:35:38 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001981 +- 0.000000372 Vs BL = -0.00396228 +- 0.00074438 Tm 16:35:40 Integrated Voltage Measurement... 16:35:48 Voltage Offset Correction: v_off_ini = -0.000001410 V, v_off_fin = -0.000001236 V 16:35:48 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002563 Vs 16:35:57 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000001398 V 16:35:57 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002775 Vs 16:36:05 Voltage Offset Correction: v_off_ini = -0.000001417 V, v_off_fin = -0.000001359 V 16:36:05 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002690 Vs 16:36:14 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000001128 V 16:36:14 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002663 Vs 16:36:22 Voltage Offset Correction: v_off_ini = -0.000001072 V, v_off_fin = -0.000000958 V 16:36:22 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002752 Vs 16:36:30 Voltage Offset Correction: v_off_ini = -0.000001447 V, v_off_fin = -0.000001513 V 16:36:30 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002760 Vs 16:36:38 Voltage Offset Correction: v_off_ini = -0.000001294 V, v_off_fin = -0.000001343 V 16:36:39 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002684 Vs 16:36:47 Voltage Offset Correction: v_off_ini = -0.000001086 V, v_off_fin = -0.000001291 V 16:36:47 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002757 Vs 16:36:55 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000001361 V 16:36:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002628 Vs 16:37:04 Voltage Offset Correction: v_off_ini = -0.000001290 V, v_off_fin = -0.000001261 V 16:37:04 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002742 Vs 16:37:12 Voltage Offset Correction: v_off_ini = -0.000001145 V, v_off_fin = -0.000001055 V 16:37:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002725 Vs 16:37:20 Voltage Offset Correction: v_off_ini = -0.000001089 V, v_off_fin = -0.000001170 V 16:37:20 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002674 Vs 16:37:29 Voltage Offset Correction: v_off_ini = -0.000001164 V, v_off_fin = -0.000001155 V 16:37:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002708 Vs 16:37:38 Voltage Offset Correction: v_off_ini = -0.000001180 V, v_off_fin = -0.000001159 V 16:37:38 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002563 Vs 16:37:47 Voltage Offset Correction: v_off_ini = -0.000001371 V, v_off_fin = -0.000001313 V 16:37:47 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002753 Vs 16:37:55 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000000857 V 16:37:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002859 Vs 16:37:55 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002706 +- 0.000000051 Vs 16:37:55 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002706 +- 0.000000051 Vs BL = 0.00541224 +- 0.00010103 Tm 16:37:55 Integrated Voltage Measurement... 16:38:04 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = -0.000001353 V 16:38:04 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001413 Vs 16:38:12 Voltage Offset Correction: v_off_ini = -0.000001189 V, v_off_fin = -0.000001231 V 16:38:12 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001552 Vs 16:38:20 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = -0.000001322 V 16:38:20 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001532 Vs 16:38:29 Voltage Offset Correction: v_off_ini = -0.000001448 V, v_off_fin = -0.000001461 V 16:38:29 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001517 Vs 16:38:37 Voltage Offset Correction: v_off_ini = -0.000001484 V, v_off_fin = -0.000001423 V 16:38:37 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001736 Vs 16:38:45 Voltage Offset Correction: v_off_ini = -0.000001172 V, v_off_fin = -0.000000878 V 16:38:45 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001344 Vs 16:38:54 Voltage Offset Correction: v_off_ini = -0.000001412 V, v_off_fin = -0.000001463 V 16:38:54 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001453 Vs 16:39:02 Voltage Offset Correction: v_off_ini = -0.000001440 V, v_off_fin = -0.000001541 V 16:39:02 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001516 Vs 16:39:10 Voltage Offset Correction: v_off_ini = -0.000001399 V, v_off_fin = -0.000001699 V 16:39:10 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001565 Vs 16:39:19 Voltage Offset Correction: v_off_ini = -0.000001072 V, v_off_fin = -0.000001058 V 16:39:19 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001483 Vs 16:39:27 Voltage Offset Correction: v_off_ini = -0.000000960 V, v_off_fin = -0.000000779 V 16:39:27 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001683 Vs 16:39:35 Voltage Offset Correction: v_off_ini = -0.000001255 V, v_off_fin = -0.000001378 V 16:39:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001556 Vs 16:39:44 Voltage Offset Correction: v_off_ini = -0.000001388 V, v_off_fin = -0.000001481 V 16:39:44 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001499 Vs 16:39:52 Voltage Offset Correction: v_off_ini = -0.000001327 V, v_off_fin = -0.000001228 V 16:39:52 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001502 Vs 16:40:00 Voltage Offset Correction: v_off_ini = -0.000001066 V, v_off_fin = -0.000001471 V 16:40:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001634 Vs 16:40:09 Voltage Offset Correction: v_off_ini = -0.000001223 V, v_off_fin = -0.000001251 V 16:40:09 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001490 Vs 16:40:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001530 +- 0.000000042 Vs 16:40:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001530 +- 0.000000042 Vs BL = 0.00305947 +- 0.00008458 Tm 16:40:09 Integrated Voltage Measurement... 16:40:17 Voltage Offset Correction: v_off_ini = -0.000001153 V, v_off_fin = -0.000001215 V 16:40:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000263 Vs 16:40:25 Voltage Offset Correction: v_off_ini = -0.000001189 V, v_off_fin = -0.000001240 V 16:40:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000336 Vs 16:40:34 Voltage Offset Correction: v_off_ini = -0.000001211 V, v_off_fin = -0.000001125 V 16:40:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000331 Vs 16:40:42 Voltage Offset Correction: v_off_ini = -0.000001059 V, v_off_fin = -0.000001208 V 16:40:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000269 Vs 16:40:51 Voltage Offset Correction: v_off_ini = -0.000001214 V, v_off_fin = -0.000001174 V 16:40:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000299 Vs 16:40:59 Voltage Offset Correction: v_off_ini = -0.000001462 V, v_off_fin = -0.000001437 V 16:40:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000326 Vs 16:41:07 Voltage Offset Correction: v_off_ini = -0.000001340 V, v_off_fin = -0.000001493 V 16:41:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000279 Vs 16:41:16 Voltage Offset Correction: v_off_ini = -0.000001393 V, v_off_fin = -0.000001266 V 16:41:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000270 Vs 16:41:24 Voltage Offset Correction: v_off_ini = -0.000001400 V, v_off_fin = -0.000001328 V 16:41:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000269 Vs 16:41:32 Voltage Offset Correction: v_off_ini = -0.000001110 V, v_off_fin = -0.000000989 V 16:41:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000274 Vs 16:41:43 Voltage Offset Correction: v_off_ini = -0.000001348 V, v_off_fin = -0.000001444 V 16:41:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000292 Vs 16:41:52 Voltage Offset Correction: v_off_ini = -0.000001174 V, v_off_fin = -0.000001024 V 16:41:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000310 Vs 16:42:00 Voltage Offset Correction: v_off_ini = -0.000001321 V, v_off_fin = -0.000001147 V 16:42:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000201 Vs 16:42:08 Voltage Offset Correction: v_off_ini = -0.000001247 V, v_off_fin = -0.000001261 V 16:42:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000310 Vs 16:42:17 Voltage Offset Correction: v_off_ini = -0.000001248 V, v_off_fin = -0.000001501 V 16:42:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000473 Vs 16:42:25 Voltage Offset Correction: v_off_ini = -0.000001229 V, v_off_fin = -0.000001318 V 16:42:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000257 Vs 16:42:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000297 +- 0.000000031 Vs 16:42:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000297 +- 0.000000031 Vs BL = 0.00059483 +- 0.00006239 Tm 16:42:25 Integrated Voltage Measurement... 16:42:34 Voltage Offset Correction: v_off_ini = -0.000001275 V, v_off_fin = -0.000001618 V 16:42:34 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000828 Vs 16:42:42 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = -0.000001112 V 16:42:42 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000001029 Vs 16:42:50 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000001216 V 16:42:50 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000784 Vs 16:42:59 Voltage Offset Correction: v_off_ini = -0.000001292 V, v_off_fin = -0.000001049 V 16:42:59 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000818 Vs 16:43:07 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000001065 V 16:43:07 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000896 Vs 16:43:15 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = -0.000001365 V 16:43:15 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000721 Vs 16:43:24 Voltage Offset Correction: v_off_ini = -0.000001162 V, v_off_fin = -0.000001272 V 16:43:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000701 Vs 16:43:32 Voltage Offset Correction: v_off_ini = -0.000001217 V, v_off_fin = -0.000001215 V 16:43:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000798 Vs 16:43:40 Voltage Offset Correction: v_off_ini = -0.000001082 V, v_off_fin = -0.000001045 V 16:43:40 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000786 Vs 16:43:49 Voltage Offset Correction: v_off_ini = -0.000001134 V, v_off_fin = -0.000001182 V 16:43:49 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000838 Vs 16:43:57 Voltage Offset Correction: v_off_ini = -0.000000963 V, v_off_fin = -0.000000840 V 16:43:57 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000732 Vs 16:44:05 Voltage Offset Correction: v_off_ini = -0.000001316 V, v_off_fin = -0.000001435 V 16:44:05 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000776 Vs 16:44:14 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = -0.000001340 V 16:44:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000776 Vs 16:44:22 Voltage Offset Correction: v_off_ini = -0.000001071 V, v_off_fin = -0.000000906 V 16:44:22 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000682 Vs 16:44:30 Voltage Offset Correction: v_off_ini = -0.000001294 V, v_off_fin = -0.000001280 V 16:44:30 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000743 Vs 16:44:39 Voltage Offset Correction: v_off_ini = -0.000001198 V, v_off_fin = -0.000001235 V 16:44:39 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000834 Vs 16:44:39 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000796 +- 0.000000057 Vs 16:44:39 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000796 +- 0.000000057 Vs BL = -0.00159268 +- 0.00011492 Tm 16:44:39 Integrated Voltage Measurement... 16:44:47 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = -0.000002104 V 16:44:47 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002425 Vs 16:44:56 Voltage Offset Correction: v_off_ini = -0.000001429 V, v_off_fin = -0.000001469 V 16:44:56 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002036 Vs 16:45:04 Voltage Offset Correction: v_off_ini = -0.000001233 V, v_off_fin = -0.000001107 V 16:45:04 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002005 Vs 16:45:12 Voltage Offset Correction: v_off_ini = -0.000001373 V, v_off_fin = -0.000001341 V 16:45:12 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002020 Vs 16:45:21 Voltage Offset Correction: v_off_ini = -0.000001201 V, v_off_fin = -0.000001238 V 16:45:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001954 Vs 16:45:29 Voltage Offset Correction: v_off_ini = -0.000001146 V, v_off_fin = -0.000001018 V 16:45:29 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002017 Vs 16:45:38 Voltage Offset Correction: v_off_ini = -0.000001263 V, v_off_fin = -0.000001291 V 16:45:39 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = 0.000000043 Vs 16:45:47 Voltage Offset Correction: v_off_ini = -0.000001267 V, v_off_fin = -0.000001317 V 16:45:47 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001928 Vs 16:45:55 Voltage Offset Correction: v_off_ini = -0.000001423 V, v_off_fin = -0.000001967 V 16:45:55 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002164 Vs 16:46:04 Voltage Offset Correction: v_off_ini = -0.000001383 V, v_off_fin = -0.000001454 V 16:46:04 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001969 Vs 16:46:12 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = -0.000001513 V 16:46:12 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000002014 Vs 16:46:20 Voltage Offset Correction: v_off_ini = -0.000001344 V, v_off_fin = -0.000001439 V 16:46:20 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001904 Vs 16:46:29 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = -0.000000982 V 16:46:29 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001997 Vs 16:46:37 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001420 V 16:46:37 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001903 Vs 16:46:45 Voltage Offset Correction: v_off_ini = -0.000001168 V, v_off_fin = -0.000001167 V 16:46:45 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001998 Vs 16:46:54 Voltage Offset Correction: v_off_ini = -0.000001174 V, v_off_fin = -0.000001072 V 16:46:54 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000002072 Vs 16:46:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001898 +- 0.000000370 Vs 16:46:54 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001898 +- 0.000000370 Vs BL = -0.00379521 +- 0.00074060 Tm 16:46:56 Integrated Voltage Measurement... 16:47:04 Voltage Offset Correction: v_off_ini = -0.000001293 V, v_off_fin = -0.000001260 V 16:47:04 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002854 Vs 16:47:12 Voltage Offset Correction: v_off_ini = -0.000001115 V, v_off_fin = -0.000001018 V 16:47:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002921 Vs 16:47:21 Voltage Offset Correction: v_off_ini = -0.000001182 V, v_off_fin = -0.000001176 V 16:47:21 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002746 Vs 16:47:29 Voltage Offset Correction: v_off_ini = -0.000001262 V, v_off_fin = -0.000001176 V 16:47:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002869 Vs 16:47:37 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001287 V 16:47:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002860 Vs 16:47:46 Voltage Offset Correction: v_off_ini = -0.000001268 V, v_off_fin = -0.000001322 V 16:47:46 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002783 Vs 16:47:54 Voltage Offset Correction: v_off_ini = -0.000001364 V, v_off_fin = -0.000000993 V 16:47:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002867 Vs 16:48:02 Voltage Offset Correction: v_off_ini = -0.000001352 V, v_off_fin = -0.000001216 V 16:48:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002807 Vs 16:48:11 Voltage Offset Correction: v_off_ini = -0.000001436 V, v_off_fin = -0.000001216 V 16:48:11 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002885 Vs 16:48:19 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000001279 V 16:48:19 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002860 Vs 16:48:27 Voltage Offset Correction: v_off_ini = -0.000001339 V, v_off_fin = -0.000001347 V 16:48:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002776 Vs 16:48:36 Voltage Offset Correction: v_off_ini = -0.000001425 V, v_off_fin = -0.000001106 V 16:48:36 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002884 Vs 16:48:44 Voltage Offset Correction: v_off_ini = -0.000001210 V, v_off_fin = -0.000001115 V 16:48:44 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002846 Vs 16:48:52 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000001094 V 16:48:52 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002840 Vs 16:49:01 Voltage Offset Correction: v_off_ini = -0.000001281 V, v_off_fin = -0.000001401 V 16:49:01 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002820 Vs 16:49:09 Voltage Offset Correction: v_off_ini = -0.000001143 V, v_off_fin = -0.000001004 V 16:49:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002900 Vs 16:49:09 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002845 +- 0.000000025 Vs 16:49:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002845 +- 0.000000025 Vs BL = 0.00568990 +- 0.00005026 Tm 16:49:09 Integrated Voltage Measurement... 16:49:18 Voltage Offset Correction: v_off_ini = -0.000001265 V, v_off_fin = -0.000001094 V 16:49:18 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001576 Vs 16:49:26 Voltage Offset Correction: v_off_ini = -0.000001228 V, v_off_fin = -0.000001422 V 16:49:26 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001577 Vs 16:49:37 Voltage Offset Correction: v_off_ini = -0.000001529 V, v_off_fin = -0.000001427 V 16:49:37 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001556 Vs 16:49:45 Voltage Offset Correction: v_off_ini = -0.000001336 V, v_off_fin = -0.000001426 V 16:49:45 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001710 Vs 16:49:53 Voltage Offset Correction: v_off_ini = -0.000001411 V, v_off_fin = -0.000001570 V 16:49:53 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001545 Vs 16:50:02 Voltage Offset Correction: v_off_ini = -0.000001289 V, v_off_fin = -0.000001311 V 16:50:02 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001631 Vs 16:50:10 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000001419 V 16:50:10 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001651 Vs 16:50:18 Voltage Offset Correction: v_off_ini = -0.000001516 V, v_off_fin = -0.000001534 V 16:50:18 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001626 Vs 16:50:27 Voltage Offset Correction: v_off_ini = -0.000001415 V, v_off_fin = -0.000001703 V 16:50:27 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001459 Vs 16:50:35 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = -0.000001300 V 16:50:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001621 Vs 16:50:43 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001361 V 16:50:43 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001598 Vs 16:50:52 Voltage Offset Correction: v_off_ini = -0.000001096 V, v_off_fin = -0.000000729 V 16:50:52 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001550 Vs 16:51:00 Voltage Offset Correction: v_off_ini = -0.000001217 V, v_off_fin = -0.000001247 V 16:51:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001665 Vs 16:51:08 Voltage Offset Correction: v_off_ini = -0.000001559 V, v_off_fin = -0.000001658 V 16:51:08 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001613 Vs 16:51:17 Voltage Offset Correction: v_off_ini = -0.000001283 V, v_off_fin = -0.000001147 V 16:51:17 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001564 Vs 16:51:25 Voltage Offset Correction: v_off_ini = -0.000001361 V, v_off_fin = -0.000001137 V 16:51:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001687 Vs 16:51:25 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001602 +- 0.000000035 Vs 16:51:25 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001602 +- 0.000000035 Vs BL = 0.00320355 +- 0.00006971 Tm 16:51:25 Integrated Voltage Measurement... 16:51:34 Voltage Offset Correction: v_off_ini = -0.000001515 V, v_off_fin = -0.000001496 V 16:51:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000473 Vs 16:51:42 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000001192 V 16:51:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000449 Vs 16:51:50 Voltage Offset Correction: v_off_ini = -0.000001336 V, v_off_fin = -0.000001913 V 16:51:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000484 Vs 16:51:59 Voltage Offset Correction: v_off_ini = -0.000001536 V, v_off_fin = -0.000001442 V 16:51:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000527 Vs 16:52:07 Voltage Offset Correction: v_off_ini = -0.000001546 V, v_off_fin = -0.000001547 V 16:52:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000505 Vs 16:52:15 Voltage Offset Correction: v_off_ini = -0.000001246 V, v_off_fin = -0.000001327 V 16:52:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000431 Vs 16:52:24 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000001194 V 16:52:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000428 Vs 16:52:32 Voltage Offset Correction: v_off_ini = -0.000001250 V, v_off_fin = -0.000001409 V 16:52:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000438 Vs 16:52:40 Voltage Offset Correction: v_off_ini = -0.000001399 V, v_off_fin = -0.000001614 V 16:52:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000447 Vs 16:52:49 Voltage Offset Correction: v_off_ini = -0.000001489 V, v_off_fin = -0.000000845 V 16:52:49 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000585 Vs 16:52:57 Voltage Offset Correction: v_off_ini = -0.000001351 V, v_off_fin = -0.000001817 V 16:52:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000640 Vs 16:53:05 Voltage Offset Correction: v_off_ini = -0.000001319 V, v_off_fin = -0.000001388 V 16:53:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000452 Vs 16:53:14 Voltage Offset Correction: v_off_ini = -0.000001279 V, v_off_fin = -0.000001181 V 16:53:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000509 Vs 16:53:22 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001702 V 16:53:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000288 Vs 16:53:30 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000001497 V 16:53:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000403 Vs 16:53:42 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = -0.000001709 V 16:53:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000073 Vs 16:53:42 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000437 +- 0.000000112 Vs 16:53:42 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000437 +- 0.000000112 Vs BL = 0.00087353 +- 0.00022352 Tm 16:53:42 Integrated Voltage Measurement... 16:53:51 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001394 V 16:53:51 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000793 Vs 16:53:59 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000001361 V 16:53:59 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000628 Vs 16:54:07 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = -0.000001467 V 16:54:07 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000722 Vs 16:54:16 Voltage Offset Correction: v_off_ini = -0.000001373 V, v_off_fin = -0.000001257 V 16:54:16 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000713 Vs 16:54:24 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000000778 V 16:54:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000831 Vs 16:54:32 Voltage Offset Correction: v_off_ini = -0.000001453 V, v_off_fin = -0.000001395 V 16:54:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000692 Vs 16:54:41 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000001327 V 16:54:41 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000683 Vs 16:54:49 Voltage Offset Correction: v_off_ini = -0.000001283 V, v_off_fin = -0.000001768 V 16:54:49 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000493 Vs 16:54:57 Voltage Offset Correction: v_off_ini = -0.000001078 V, v_off_fin = -0.000001050 V 16:54:57 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000712 Vs 16:55:06 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000001479 V 16:55:06 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000685 Vs 16:55:14 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000001427 V 16:55:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000630 Vs 16:55:22 Voltage Offset Correction: v_off_ini = -0.000001386 V, v_off_fin = -0.000001212 V 16:55:22 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000709 Vs 16:55:31 Voltage Offset Correction: v_off_ini = -0.000001182 V, v_off_fin = -0.000001460 V 16:55:31 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000716 Vs 16:55:39 Voltage Offset Correction: v_off_ini = -0.000001227 V, v_off_fin = -0.000001181 V 16:55:39 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000674 Vs 16:55:47 Voltage Offset Correction: v_off_ini = -0.000001299 V, v_off_fin = -0.000001429 V 16:55:47 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000711 Vs 16:55:56 Voltage Offset Correction: v_off_ini = -0.000001335 V, v_off_fin = -0.000001435 V 16:55:56 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000718 Vs 16:55:56 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000694 +- 0.000000047 Vs 16:55:56 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000694 +- 0.000000047 Vs BL = -0.00138861 +- 0.00009402 Tm 16:55:56 Integrated Voltage Measurement... 16:56:04 Voltage Offset Correction: v_off_ini = -0.000001194 V, v_off_fin = -0.000001444 V 16:56:04 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001786 Vs 16:56:13 Voltage Offset Correction: v_off_ini = -0.000001222 V, v_off_fin = -0.000001154 V 16:56:13 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001891 Vs 16:56:21 Voltage Offset Correction: v_off_ini = -0.000001124 V, v_off_fin = -0.000001072 V 16:56:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001869 Vs 16:56:29 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001105 V 16:56:29 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001880 Vs 16:56:38 Voltage Offset Correction: v_off_ini = -0.000001285 V, v_off_fin = -0.000001173 V 16:56:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001924 Vs 16:56:46 Voltage Offset Correction: v_off_ini = -0.000001249 V, v_off_fin = -0.000001499 V 16:56:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001803 Vs 16:56:55 Voltage Offset Correction: v_off_ini = -0.000001193 V, v_off_fin = -0.000001149 V 16:56:55 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001800 Vs 16:57:03 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000001415 V 16:57:03 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001877 Vs 16:57:11 Voltage Offset Correction: v_off_ini = -0.000001285 V, v_off_fin = -0.000001317 V 16:57:11 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001833 Vs 16:57:20 Voltage Offset Correction: v_off_ini = -0.000001334 V, v_off_fin = -0.000001525 V 16:57:20 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001747 Vs 16:57:28 Voltage Offset Correction: v_off_ini = -0.000001350 V, v_off_fin = -0.000001388 V 16:57:28 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001937 Vs 16:57:38 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = -0.000001391 V 16:57:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001873 Vs 16:57:46 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001283 V 16:57:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001979 Vs 16:57:55 Voltage Offset Correction: v_off_ini = -0.000001256 V, v_off_fin = -0.000001280 V 16:57:55 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001834 Vs 16:58:03 Voltage Offset Correction: v_off_ini = -0.000001499 V, v_off_fin = -0.000001107 V 16:58:03 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001789 Vs 16:58:11 Voltage Offset Correction: v_off_ini = -0.000001218 V, v_off_fin = -0.000001230 V 16:58:11 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001854 Vs 16:58:12 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001855 +- 0.000000038 Vs 16:58:12 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001855 +- 0.000000038 Vs BL = -0.00370958 +- 0.00007603 Tm 16:58:13 Integrated Voltage Measurement... 16:58:22 Voltage Offset Correction: v_off_ini = -0.000001291 V, v_off_fin = -0.000001205 V 16:58:22 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002971 Vs 16:58:30 Voltage Offset Correction: v_off_ini = -0.000001233 V, v_off_fin = -0.000001140 V 16:58:30 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003003 Vs 16:58:38 Voltage Offset Correction: v_off_ini = -0.000001256 V, v_off_fin = -0.000001301 V 16:58:38 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002952 Vs 16:58:47 Voltage Offset Correction: v_off_ini = -0.000001268 V, v_off_fin = -0.000001015 V 16:58:47 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002877 Vs 16:58:55 Voltage Offset Correction: v_off_ini = -0.000001207 V, v_off_fin = -0.000001193 V 16:58:55 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002908 Vs 16:59:04 Voltage Offset Correction: v_off_ini = -0.000001102 V, v_off_fin = -0.000001060 V 16:59:04 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002987 Vs 16:59:12 Voltage Offset Correction: v_off_ini = -0.000001394 V, v_off_fin = -0.000001256 V 16:59:12 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002906 Vs 16:59:20 Voltage Offset Correction: v_off_ini = -0.000001186 V, v_off_fin = -0.000001392 V 16:59:20 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002944 Vs 16:59:29 Voltage Offset Correction: v_off_ini = -0.000001322 V, v_off_fin = -0.000001311 V 16:59:29 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002863 Vs 16:59:37 Voltage Offset Correction: v_off_ini = -0.000001094 V, v_off_fin = -0.000001136 V 16:59:37 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002968 Vs 16:59:45 Voltage Offset Correction: v_off_ini = -0.000001209 V, v_off_fin = -0.000001302 V 16:59:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002908 Vs 16:59:54 Voltage Offset Correction: v_off_ini = -0.000001388 V, v_off_fin = -0.000001171 V 16:59:54 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002930 Vs 17:00:02 Voltage Offset Correction: v_off_ini = -0.000001300 V, v_off_fin = -0.000001113 V 17:00:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002945 Vs 17:00:10 Voltage Offset Correction: v_off_ini = -0.000001355 V, v_off_fin = -0.000001229 V 17:00:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002935 Vs 17:00:19 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = -0.000001264 V 17:00:19 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002914 Vs 17:00:27 Voltage Offset Correction: v_off_ini = -0.000001269 V, v_off_fin = -0.000001280 V 17:00:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000002924 Vs 17:00:27 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002933 +- 0.000000023 Vs 17:00:27 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002933 +- 0.000000023 Vs BL = 0.00586692 +- 0.00004647 Tm 17:00:27 Integrated Voltage Measurement... 17:00:36 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001221 V 17:00:36 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001767 Vs 17:00:44 Voltage Offset Correction: v_off_ini = -0.000001453 V, v_off_fin = -0.000001028 V 17:00:44 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001586 Vs 17:00:52 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000001254 V 17:00:52 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001766 Vs 17:01:01 Voltage Offset Correction: v_off_ini = -0.000001301 V, v_off_fin = -0.000001277 V 17:01:01 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001807 Vs 17:01:09 Voltage Offset Correction: v_off_ini = -0.000001275 V, v_off_fin = -0.000001694 V 17:01:09 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001705 Vs 17:01:17 Voltage Offset Correction: v_off_ini = -0.000001428 V, v_off_fin = -0.000001400 V 17:01:17 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001730 Vs 17:01:26 Voltage Offset Correction: v_off_ini = -0.000001188 V, v_off_fin = -0.000001278 V 17:01:26 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001746 Vs 17:01:35 Voltage Offset Correction: v_off_ini = -0.000001401 V, v_off_fin = -0.000001580 V 17:01:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001701 Vs 17:01:45 Voltage Offset Correction: v_off_ini = -0.000001299 V, v_off_fin = -0.000001340 V 17:01:45 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001665 Vs 17:01:53 Voltage Offset Correction: v_off_ini = -0.000001243 V, v_off_fin = -0.000001362 V 17:01:53 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001776 Vs 17:02:02 Voltage Offset Correction: v_off_ini = -0.000001190 V, v_off_fin = -0.000001215 V 17:02:02 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001768 Vs 17:02:10 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000001292 V 17:02:10 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001811 Vs 17:02:18 Voltage Offset Correction: v_off_ini = -0.000001437 V, v_off_fin = -0.000001416 V 17:02:18 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001727 Vs 17:02:27 Voltage Offset Correction: v_off_ini = -0.000001251 V, v_off_fin = -0.000001189 V 17:02:27 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001786 Vs 17:02:35 Voltage Offset Correction: v_off_ini = -0.000001421 V, v_off_fin = -0.000001460 V 17:02:35 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001734 Vs 17:02:43 Voltage Offset Correction: v_off_ini = -0.000001272 V, v_off_fin = -0.000001270 V 17:02:43 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001751 Vs 17:02:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001739 +- 0.000000035 Vs 17:02:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001739 +- 0.000000035 Vs BL = 0.00347829 +- 0.00007083 Tm 17:02:44 Integrated Voltage Measurement... 17:02:52 Voltage Offset Correction: v_off_ini = -0.000001268 V, v_off_fin = -0.000001185 V 17:02:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000564 Vs 17:03:00 Voltage Offset Correction: v_off_ini = -0.000001318 V, v_off_fin = -0.000001273 V 17:03:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000595 Vs 17:03:08 Voltage Offset Correction: v_off_ini = -0.000001342 V, v_off_fin = -0.000001466 V 17:03:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000527 Vs 17:03:17 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000001024 V 17:03:17 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000598 Vs 17:03:25 Voltage Offset Correction: v_off_ini = -0.000001321 V, v_off_fin = -0.000001265 V 17:03:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000593 Vs 17:03:33 Voltage Offset Correction: v_off_ini = -0.000001161 V, v_off_fin = -0.000001022 V 17:03:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000627 Vs 17:03:42 Voltage Offset Correction: v_off_ini = -0.000001467 V, v_off_fin = -0.000001476 V 17:03:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000655 Vs 17:03:50 Voltage Offset Correction: v_off_ini = -0.000001223 V, v_off_fin = -0.000001437 V 17:03:50 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000606 Vs 17:03:59 Voltage Offset Correction: v_off_ini = -0.000001240 V, v_off_fin = -0.000001189 V 17:03:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000541 Vs 17:04:07 Voltage Offset Correction: v_off_ini = -0.000001369 V, v_off_fin = -0.000001272 V 17:04:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000588 Vs 17:04:15 Voltage Offset Correction: v_off_ini = -0.000001147 V, v_off_fin = -0.000001157 V 17:04:15 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000547 Vs 17:04:23 Voltage Offset Correction: v_off_ini = -0.000001209 V, v_off_fin = -0.000001110 V 17:04:23 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000578 Vs 17:04:32 Voltage Offset Correction: v_off_ini = -0.000001151 V, v_off_fin = -0.000001131 V 17:04:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000566 Vs 17:04:40 Voltage Offset Correction: v_off_ini = -0.000001082 V, v_off_fin = -0.000001042 V 17:04:40 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000569 Vs 17:04:48 Voltage Offset Correction: v_off_ini = -0.000001275 V, v_off_fin = -0.000000691 V 17:04:48 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000805 Vs 17:04:57 Voltage Offset Correction: v_off_ini = -0.000001407 V, v_off_fin = -0.000001409 V 17:04:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000694 Vs 17:04:57 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000603 +- 0.000000060 Vs 17:04:57 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000603 +- 0.000000060 Vs BL = 0.00120658 +- 0.00012011 Tm 17:04:57 Integrated Voltage Measurement... 17:05:05 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001407 V 17:05:05 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000464 Vs 17:05:14 Voltage Offset Correction: v_off_ini = -0.000001437 V, v_off_fin = -0.000001584 V 17:05:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000616 Vs 17:05:22 Voltage Offset Correction: v_off_ini = -0.000001375 V, v_off_fin = -0.000001344 V 17:05:22 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000604 Vs 17:05:30 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001273 V 17:05:30 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000538 Vs 17:05:42 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = -0.000001392 V 17:05:42 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = 0.000000089 Vs 17:05:50 Voltage Offset Correction: v_off_ini = -0.000001496 V, v_off_fin = -0.000001369 V 17:05:51 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000683 Vs 17:05:59 Voltage Offset Correction: v_off_ini = -0.000001076 V, v_off_fin = -0.000001033 V 17:05:59 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000446 Vs 17:06:07 Voltage Offset Correction: v_off_ini = -0.000001460 V, v_off_fin = -0.000001469 V 17:06:07 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000618 Vs 17:06:16 Voltage Offset Correction: v_off_ini = -0.000001462 V, v_off_fin = -0.000001470 V 17:06:16 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000617 Vs 17:06:24 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001298 V 17:06:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000489 Vs 17:06:32 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001367 V 17:06:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000470 Vs 17:06:41 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000001170 V 17:06:41 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000596 Vs 17:06:49 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001411 V 17:06:49 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000560 Vs 17:06:57 Voltage Offset Correction: v_off_ini = -0.000001333 V, v_off_fin = -0.000001655 V 17:06:57 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000499 Vs 17:07:06 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000001140 V 17:07:06 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000527 Vs 17:07:14 Voltage Offset Correction: v_off_ini = -0.000001431 V, v_off_fin = -0.000001482 V 17:07:14 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000494 Vs 17:07:14 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000508 +- 0.000000081 Vs 17:07:14 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000508 +- 0.000000081 Vs BL = -0.00101665 +- 0.00016297 Tm 17:07:14 Integrated Voltage Measurement... 17:07:23 Voltage Offset Correction: v_off_ini = -0.000001232 V, v_off_fin = -0.000001460 V 17:07:23 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001723 Vs 17:07:31 Voltage Offset Correction: v_off_ini = -0.000001104 V, v_off_fin = -0.000001098 V 17:07:31 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001760 Vs 17:07:39 Voltage Offset Correction: v_off_ini = -0.000001235 V, v_off_fin = -0.000001576 V 17:07:39 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001771 Vs 17:07:48 Voltage Offset Correction: v_off_ini = -0.000001276 V, v_off_fin = -0.000001149 V 17:07:48 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001709 Vs 17:07:56 Voltage Offset Correction: v_off_ini = -0.000001356 V, v_off_fin = -0.000001561 V 17:07:56 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001770 Vs 17:08:04 Voltage Offset Correction: v_off_ini = -0.000001332 V, v_off_fin = -0.000001373 V 17:08:04 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001753 Vs 17:08:13 Voltage Offset Correction: v_off_ini = -0.000001123 V, v_off_fin = -0.000001028 V 17:08:13 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001740 Vs 17:08:21 Voltage Offset Correction: v_off_ini = -0.000001376 V, v_off_fin = -0.000001285 V 17:08:21 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001700 Vs 17:08:30 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000001243 V 17:08:30 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001712 Vs 17:08:38 Voltage Offset Correction: v_off_ini = -0.000001363 V, v_off_fin = -0.000001442 V 17:08:38 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001754 Vs 17:08:46 Voltage Offset Correction: v_off_ini = -0.000001191 V, v_off_fin = -0.000000986 V 17:08:46 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001713 Vs 17:08:55 Voltage Offset Correction: v_off_ini = -0.000001377 V, v_off_fin = -0.000001515 V 17:08:55 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001757 Vs 17:09:03 Voltage Offset Correction: v_off_ini = -0.000001402 V, v_off_fin = -0.000001326 V 17:09:03 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001696 Vs 17:09:11 Voltage Offset Correction: v_off_ini = -0.000001371 V, v_off_fin = -0.000001471 V 17:09:11 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001980 Vs 17:09:20 Voltage Offset Correction: v_off_ini = -0.000001309 V, v_off_fin = -0.000001305 V 17:09:20 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001741 Vs 17:09:28 Voltage Offset Correction: v_off_ini = -0.000001400 V, v_off_fin = -0.000001162 V 17:09:28 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001715 Vs 17:09:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001749 +- 0.000000035 Vs 17:09:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001749 +- 0.000000035 Vs BL = -0.00349895 +- 0.00007064 Tm 17:09:30 Integrated Voltage Measurement... 17:09:42 Voltage Offset Correction: v_off_ini = -0.000001194 V, v_off_fin = -0.000001304 V 17:09:42 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = -0.000000089 Vs 17:09:50 Voltage Offset Correction: v_off_ini = -0.000001454 V, v_off_fin = -0.000001388 V 17:09:50 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003180 Vs 17:09:59 Voltage Offset Correction: v_off_ini = -0.000001347 V, v_off_fin = -0.000000956 V 17:09:59 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003130 Vs 17:10:07 Voltage Offset Correction: v_off_ini = -0.000001365 V, v_off_fin = -0.000001596 V 17:10:07 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003191 Vs 17:10:15 Voltage Offset Correction: v_off_ini = -0.000001289 V, v_off_fin = -0.000001313 V 17:10:15 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003025 Vs 17:10:24 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001209 V 17:10:24 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003114 Vs 17:10:32 Voltage Offset Correction: v_off_ini = -0.000001310 V, v_off_fin = -0.000001368 V 17:10:32 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003075 Vs 17:10:40 Voltage Offset Correction: v_off_ini = -0.000001444 V, v_off_fin = -0.000001416 V 17:10:40 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003132 Vs 17:10:49 Voltage Offset Correction: v_off_ini = -0.000001233 V, v_off_fin = -0.000001389 V 17:10:49 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003097 Vs 17:10:57 Voltage Offset Correction: v_off_ini = -0.000001273 V, v_off_fin = -0.000001471 V 17:10:57 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003005 Vs 17:11:05 Voltage Offset Correction: v_off_ini = -0.000001384 V, v_off_fin = -0.000001383 V 17:11:05 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003098 Vs 17:11:14 Voltage Offset Correction: v_off_ini = -0.000001164 V, v_off_fin = -0.000001236 V 17:11:14 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003141 Vs 17:11:22 Voltage Offset Correction: v_off_ini = -0.000001451 V, v_off_fin = -0.000001105 V 17:11:22 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003275 Vs 17:11:30 Voltage Offset Correction: v_off_ini = -0.000001575 V, v_off_fin = -0.000001648 V 17:11:30 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003081 Vs 17:11:39 Voltage Offset Correction: v_off_ini = -0.000001297 V, v_off_fin = -0.000001279 V 17:11:39 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003007 Vs 17:11:47 Voltage Offset Correction: v_off_ini = -0.000001362 V, v_off_fin = -0.000001082 V 17:11:47 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003062 Vs 17:11:47 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000002908 +- 0.000000517 Vs 17:11:47 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002908 +- 0.000000517 Vs BL = 0.00581540 +- 0.00103406 Tm 17:11:47 Integrated Voltage Measurement... 17:11:55 Voltage Offset Correction: v_off_ini = -0.000001299 V, v_off_fin = -0.000001678 V 17:11:55 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001816 Vs 17:12:04 Voltage Offset Correction: v_off_ini = -0.000001427 V, v_off_fin = -0.000001485 V 17:12:04 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001923 Vs 17:12:12 Voltage Offset Correction: v_off_ini = -0.000001196 V, v_off_fin = -0.000001232 V 17:12:12 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001946 Vs 17:12:20 Voltage Offset Correction: v_off_ini = -0.000001218 V, v_off_fin = -0.000001214 V 17:12:20 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001951 Vs 17:12:29 Voltage Offset Correction: v_off_ini = -0.000001391 V, v_off_fin = -0.000001282 V 17:12:29 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001851 Vs 17:12:37 Voltage Offset Correction: v_off_ini = -0.000001224 V, v_off_fin = -0.000001108 V 17:12:37 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001908 Vs 17:12:45 Voltage Offset Correction: v_off_ini = -0.000001316 V, v_off_fin = -0.000000928 V 17:12:45 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001931 Vs 17:12:54 Voltage Offset Correction: v_off_ini = -0.000001418 V, v_off_fin = -0.000001417 V 17:12:54 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001892 Vs 17:13:02 Voltage Offset Correction: v_off_ini = -0.000001291 V, v_off_fin = -0.000001397 V 17:13:02 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001919 Vs 17:13:10 Voltage Offset Correction: v_off_ini = -0.000001469 V, v_off_fin = -0.000001412 V 17:13:10 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001897 Vs 17:13:19 Voltage Offset Correction: v_off_ini = -0.000001311 V, v_off_fin = -0.000001310 V 17:13:19 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001990 Vs 17:13:27 Voltage Offset Correction: v_off_ini = -0.000001303 V, v_off_fin = -0.000001617 V 17:13:27 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001798 Vs 17:13:38 Voltage Offset Correction: v_off_ini = -0.000001442 V, v_off_fin = -0.000001347 V 17:13:38 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001996 Vs 17:13:46 Voltage Offset Correction: v_off_ini = -0.000001458 V, v_off_fin = -0.000001566 V 17:13:46 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001846 Vs 17:13:54 Voltage Offset Correction: v_off_ini = -0.000001169 V, v_off_fin = -0.000001072 V 17:13:54 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001848 Vs 17:14:03 Voltage Offset Correction: v_off_ini = -0.000001530 V, v_off_fin = -0.000001467 V 17:14:03 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001966 Vs 17:14:03 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001905 +- 0.000000023 Vs 17:14:03 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000001905 +- 0.000000023 Vs BL = 0.00380978 +- 0.00004581 Tm 17:14:03 Integrated Voltage Measurement... 17:14:11 Voltage Offset Correction: v_off_ini = -0.000001230 V, v_off_fin = -0.000001316 V 17:14:11 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000675 Vs 17:14:19 Voltage Offset Correction: v_off_ini = -0.000001337 V, v_off_fin = -0.000001618 V 17:14:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000636 Vs 17:14:28 Voltage Offset Correction: v_off_ini = -0.000001353 V, v_off_fin = -0.000001377 V 17:14:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000572 Vs 17:14:36 Voltage Offset Correction: v_off_ini = -0.000001005 V, v_off_fin = -0.000001106 V 17:14:36 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000680 Vs 17:14:44 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = -0.000001248 V 17:14:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000746 Vs 17:14:53 Voltage Offset Correction: v_off_ini = -0.000001240 V, v_off_fin = -0.000001457 V 17:14:53 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000773 Vs 17:15:01 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001200 V 17:15:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000733 Vs 17:15:09 Voltage Offset Correction: v_off_ini = -0.000001263 V, v_off_fin = -0.000001319 V 17:15:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000648 Vs 17:15:18 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001080 V 17:15:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000693 Vs 17:15:26 Voltage Offset Correction: v_off_ini = -0.000001247 V, v_off_fin = -0.000001233 V 17:15:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000709 Vs 17:15:34 Voltage Offset Correction: v_off_ini = -0.000001463 V, v_off_fin = -0.000001382 V 17:15:34 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000731 Vs 17:15:43 Voltage Offset Correction: v_off_ini = -0.000001420 V, v_off_fin = -0.000001349 V 17:15:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000698 Vs 17:15:51 Voltage Offset Correction: v_off_ini = -0.000001193 V, v_off_fin = -0.000001019 V 17:15:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000654 Vs 17:15:59 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001485 V 17:15:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000651 Vs 17:16:08 Voltage Offset Correction: v_off_ini = -0.000001283 V, v_off_fin = -0.000000980 V 17:16:08 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000614 Vs 17:16:16 Voltage Offset Correction: v_off_ini = -0.000001246 V, v_off_fin = -0.000001423 V 17:16:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000832 Vs 17:16:16 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000690 +- 0.000000041 Vs 17:16:16 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000690 +- 0.000000041 Vs BL = 0.00138060 +- 0.00008158 Tm 17:16:16 Integrated Voltage Measurement... 17:16:25 Voltage Offset Correction: v_off_ini = -0.000001360 V, v_off_fin = -0.000001432 V 17:16:25 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000556 Vs 17:16:33 Voltage Offset Correction: v_off_ini = -0.000001212 V, v_off_fin = -0.000001066 V 17:16:33 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000495 Vs 17:16:41 Voltage Offset Correction: v_off_ini = -0.000001175 V, v_off_fin = -0.000001038 V 17:16:41 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000539 Vs 17:16:50 Voltage Offset Correction: v_off_ini = -0.000001364 V, v_off_fin = -0.000001392 V 17:16:50 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000433 Vs 17:16:58 Voltage Offset Correction: v_off_ini = -0.000001352 V, v_off_fin = -0.000001347 V 17:16:58 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000517 Vs 17:17:06 Voltage Offset Correction: v_off_ini = -0.000001370 V, v_off_fin = -0.000001552 V 17:17:06 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000439 Vs 17:17:15 Voltage Offset Correction: v_off_ini = -0.000001258 V, v_off_fin = -0.000001329 V 17:17:15 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000503 Vs 17:17:23 Voltage Offset Correction: v_off_ini = -0.000001551 V, v_off_fin = -0.000001448 V 17:17:23 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000476 Vs 17:17:31 Voltage Offset Correction: v_off_ini = -0.000001216 V, v_off_fin = -0.000001367 V 17:17:31 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000542 Vs 17:17:43 Voltage Offset Correction: v_off_ini = -0.000001286 V, v_off_fin = -0.000001478 V 17:17:43 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000476 Vs 17:17:51 Voltage Offset Correction: v_off_ini = -0.000001324 V, v_off_fin = -0.000001408 V 17:17:52 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000482 Vs 17:18:00 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000001071 V 17:18:00 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000409 Vs 17:18:09 Voltage Offset Correction: v_off_ini = -0.000001395 V, v_off_fin = -0.000001268 V 17:18:09 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000425 Vs 17:18:17 Voltage Offset Correction: v_off_ini = -0.000001533 V, v_off_fin = -0.000001543 V 17:18:18 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000414 Vs 17:18:26 Voltage Offset Correction: v_off_ini = -0.000001169 V, v_off_fin = -0.000001394 V 17:18:26 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000456 Vs 17:18:35 Voltage Offset Correction: v_off_ini = -0.000001326 V, v_off_fin = -0.000001470 V 17:18:35 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000567 Vs 17:18:35 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000483 +- 0.000000033 Vs 17:18:35 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000483 +- 0.000000033 Vs BL = -0.00096628 +- 0.00006620 Tm 17:18:36 Integrated Voltage Measurement... 17:18:44 Voltage Offset Correction: v_off_ini = -0.000001280 V, v_off_fin = -0.000001195 V 17:18:44 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001757 Vs 17:18:53 Voltage Offset Correction: v_off_ini = -0.000001287 V, v_off_fin = -0.000001346 V 17:18:53 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001633 Vs 17:19:01 Voltage Offset Correction: v_off_ini = -0.000001203 V, v_off_fin = -0.000001146 V 17:19:01 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001682 Vs 17:19:10 Voltage Offset Correction: v_off_ini = -0.000001285 V, v_off_fin = -0.000001142 V 17:19:10 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001663 Vs 17:19:18 Voltage Offset Correction: v_off_ini = -0.000001527 V, v_off_fin = -0.000001271 V 17:19:18 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001715 Vs 17:19:26 Voltage Offset Correction: v_off_ini = -0.000001425 V, v_off_fin = -0.000001433 V 17:19:26 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001690 Vs 17:19:35 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001156 V 17:19:35 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001693 Vs 17:19:43 Voltage Offset Correction: v_off_ini = -0.000001351 V, v_off_fin = -0.000001349 V 17:19:43 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001626 Vs 17:19:52 Voltage Offset Correction: v_off_ini = -0.000001110 V, v_off_fin = -0.000001162 V 17:19:52 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001658 Vs 17:20:00 Voltage Offset Correction: v_off_ini = -0.000001252 V, v_off_fin = -0.000001243 V 17:20:00 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001657 Vs 17:20:08 Voltage Offset Correction: v_off_ini = -0.000001171 V, v_off_fin = -0.000001262 V 17:20:08 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001683 Vs 17:20:17 Voltage Offset Correction: v_off_ini = -0.000001406 V, v_off_fin = -0.000001352 V 17:20:17 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001618 Vs 17:20:25 Voltage Offset Correction: v_off_ini = -0.000001279 V, v_off_fin = -0.000001019 V 17:20:25 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001541 Vs 17:20:33 Voltage Offset Correction: v_off_ini = -0.000001313 V, v_off_fin = -0.000001259 V 17:20:33 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001632 Vs 17:20:42 Voltage Offset Correction: v_off_ini = -0.000001098 V, v_off_fin = -0.000001074 V 17:20:42 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001664 Vs 17:20:50 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000001247 V 17:20:50 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001700 Vs 17:20:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001663 +- 0.000000034 Vs 17:20:50 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001663 +- 0.000000034 Vs BL = -0.00332637 +- 0.00006748 Tm 17:20:52 Integrated Voltage Measurement... 17:21:00 Voltage Offset Correction: v_off_ini = -0.000001259 V, v_off_fin = -0.000001112 V 17:21:00 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003184 Vs 17:21:09 Voltage Offset Correction: v_off_ini = -0.000000996 V, v_off_fin = -0.000001003 V 17:21:09 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003212 Vs 17:21:17 Voltage Offset Correction: v_off_ini = -0.000001264 V, v_off_fin = -0.000001248 V 17:21:17 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003195 Vs 17:21:25 Voltage Offset Correction: v_off_ini = -0.000001352 V, v_off_fin = -0.000001264 V 17:21:25 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003186 Vs 17:21:35 Voltage Offset Correction: v_off_ini = -0.000001246 V, v_off_fin = -0.000001266 V 17:21:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003258 Vs 17:21:45 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = -0.000001218 V 17:21:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003165 Vs 17:21:53 Voltage Offset Correction: v_off_ini = -0.000001116 V, v_off_fin = -0.000001216 V 17:21:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003154 Vs 17:22:02 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001630 V 17:22:02 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003231 Vs 17:22:10 Voltage Offset Correction: v_off_ini = -0.000001114 V, v_off_fin = -0.000001035 V 17:22:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003259 Vs 17:22:18 Voltage Offset Correction: v_off_ini = -0.000001312 V, v_off_fin = -0.000001265 V 17:22:18 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003145 Vs 17:22:27 Voltage Offset Correction: v_off_ini = -0.000001378 V, v_off_fin = -0.000001296 V 17:22:27 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003179 Vs 17:22:35 Voltage Offset Correction: v_off_ini = -0.000001264 V, v_off_fin = -0.000001261 V 17:22:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003229 Vs 17:22:43 Voltage Offset Correction: v_off_ini = -0.000001423 V, v_off_fin = -0.000000948 V 17:22:43 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003367 Vs 17:22:52 Voltage Offset Correction: v_off_ini = -0.000001074 V, v_off_fin = -0.000001374 V 17:22:52 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003385 Vs 17:23:00 Voltage Offset Correction: v_off_ini = -0.000001344 V, v_off_fin = -0.000001518 V 17:23:00 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003265 Vs 17:23:08 Voltage Offset Correction: v_off_ini = -0.000001366 V, v_off_fin = -0.000001324 V 17:23:08 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003277 Vs 17:23:08 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003231 +- 0.000000060 Vs 17:23:09 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000003231 +- 0.000000060 Vs BL = 0.00646121 +- 0.00012020 Tm 17:23:09 Integrated Voltage Measurement... 17:23:17 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = -0.000001400 V 17:23:17 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002125 Vs 17:23:25 Voltage Offset Correction: v_off_ini = -0.000001323 V, v_off_fin = -0.000001237 V 17:23:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001993 Vs 17:23:34 Voltage Offset Correction: v_off_ini = -0.000001298 V, v_off_fin = -0.000001060 V 17:23:34 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002076 Vs 17:23:42 Voltage Offset Correction: v_off_ini = -0.000001320 V, v_off_fin = -0.000001224 V 17:23:42 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001985 Vs 17:23:50 Voltage Offset Correction: v_off_ini = -0.000001379 V, v_off_fin = -0.000001242 V 17:23:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002006 Vs 17:23:59 Voltage Offset Correction: v_off_ini = -0.000001281 V, v_off_fin = -0.000001258 V 17:23:59 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002031 Vs 17:24:07 Voltage Offset Correction: v_off_ini = -0.000001206 V, v_off_fin = -0.000001180 V 17:24:07 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002040 Vs 17:24:15 Voltage Offset Correction: v_off_ini = -0.000001141 V, v_off_fin = -0.000001317 V 17:24:15 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001997 Vs 17:24:24 Voltage Offset Correction: v_off_ini = -0.000001524 V, v_off_fin = -0.000001276 V 17:24:24 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001998 Vs 17:24:32 Voltage Offset Correction: v_off_ini = -0.000001507 V, v_off_fin = -0.000001311 V 17:24:32 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001981 Vs 17:24:40 Voltage Offset Correction: v_off_ini = -0.000001307 V, v_off_fin = -0.000001277 V 17:24:40 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002157 Vs 17:24:49 Voltage Offset Correction: v_off_ini = -0.000001331 V, v_off_fin = -0.000001282 V 17:24:49 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000001949 Vs 17:24:57 Voltage Offset Correction: v_off_ini = -0.000001615 V, v_off_fin = -0.000001563 V 17:24:57 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001997 Vs 17:25:05 Voltage Offset Correction: v_off_ini = -0.000001151 V, v_off_fin = -0.000001204 V 17:25:05 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002111 Vs 17:25:14 Voltage Offset Correction: v_off_ini = -0.000001266 V, v_off_fin = -0.000001217 V 17:25:14 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000001981 Vs 17:25:22 Voltage Offset Correction: v_off_ini = -0.000001330 V, v_off_fin = -0.000001510 V 17:25:22 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002048 Vs 17:25:22 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002030 +- 0.000000023 Vs 17:25:22 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002030 +- 0.000000023 Vs BL = 0.00405952 +- 0.00004515 Tm 17:25:22 Integrated Voltage Measurement... 17:25:31 Voltage Offset Correction: v_off_ini = -0.000001093 V, v_off_fin = -0.000001179 V 17:25:31 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000817 Vs 17:25:42 Voltage Offset Correction: v_off_ini = -0.000001297 V, v_off_fin = -0.000001241 V 17:25:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000119 Vs 17:25:51 Voltage Offset Correction: v_off_ini = -0.000001355 V, v_off_fin = -0.000001365 V 17:25:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000849 Vs 17:25:59 Voltage Offset Correction: v_off_ini = -0.000001363 V, v_off_fin = -0.000001582 V 17:25:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000794 Vs 17:26:07 Voltage Offset Correction: v_off_ini = -0.000001200 V, v_off_fin = -0.000001255 V 17:26:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000832 Vs 17:26:16 Voltage Offset Correction: v_off_ini = -0.000001209 V, v_off_fin = -0.000001173 V 17:26:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000781 Vs 17:26:24 Voltage Offset Correction: v_off_ini = -0.000001198 V, v_off_fin = -0.000001098 V 17:26:24 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000763 Vs 17:26:32 Voltage Offset Correction: v_off_ini = -0.000001357 V, v_off_fin = -0.000001364 V 17:26:32 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000795 Vs 17:26:41 Voltage Offset Correction: v_off_ini = -0.000001192 V, v_off_fin = -0.000001165 V 17:26:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000814 Vs 17:26:52 Voltage Offset Correction: v_off_ini = -0.000001434 V, v_off_fin = -0.000001005 V 17:26:52 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000655 Vs 17:27:01 Voltage Offset Correction: v_off_ini = -0.000001256 V, v_off_fin = -0.000001378 V 17:27:01 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000903 Vs 17:27:09 Voltage Offset Correction: v_off_ini = -0.000001403 V, v_off_fin = -0.000001334 V 17:27:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000786 Vs 17:27:18 Voltage Offset Correction: v_off_ini = -0.000001231 V, v_off_fin = -0.000001503 V 17:27:18 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000843 Vs 17:27:26 Voltage Offset Correction: v_off_ini = -0.000001218 V, v_off_fin = -0.000001184 V 17:27:26 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000836 Vs 17:27:34 Voltage Offset Correction: v_off_ini = -0.000001187 V, v_off_fin = -0.000001168 V 17:27:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000781 Vs 17:27:43 Voltage Offset Correction: v_off_ini = -0.000001367 V, v_off_fin = -0.000001104 V 17:27:43 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000834 Vs 17:27:43 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000763 +- 0.000000116 Vs 17:27:43 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000000763 +- 0.000000116 Vs BL = 0.00152541 +- 0.00023237 Tm 17:27:43 Integrated Voltage Measurement... 17:27:52 Voltage Offset Correction: v_off_ini = -0.000001329 V, v_off_fin = -0.000001757 V 17:27:52 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000595 Vs 17:28:00 Voltage Offset Correction: v_off_ini = -0.000001509 V, v_off_fin = -0.000001641 V 17:28:00 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000282 Vs 17:28:08 Voltage Offset Correction: v_off_ini = -0.000001094 V, v_off_fin = -0.000001041 V 17:28:08 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000419 Vs 17:28:17 Voltage Offset Correction: v_off_ini = -0.000001386 V, v_off_fin = -0.000001506 V 17:28:17 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000331 Vs 17:28:25 Voltage Offset Correction: v_off_ini = -0.000001196 V, v_off_fin = -0.000001109 V 17:28:25 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000442 Vs 17:28:33 Voltage Offset Correction: v_off_ini = -0.000001224 V, v_off_fin = -0.000000825 V 17:28:34 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000363 Vs 17:28:42 Voltage Offset Correction: v_off_ini = -0.000001112 V, v_off_fin = -0.000001239 V 17:28:42 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000361 Vs 17:28:50 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000001459 V 17:28:50 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000306 Vs 17:28:59 Voltage Offset Correction: v_off_ini = -0.000001440 V, v_off_fin = -0.000001448 V 17:28:59 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000339 Vs 17:29:07 Voltage Offset Correction: v_off_ini = -0.000001261 V, v_off_fin = -0.000001457 V 17:29:07 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000294 Vs 17:29:15 Voltage Offset Correction: v_off_ini = -0.000001281 V, v_off_fin = -0.000001264 V 17:29:15 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000326 Vs 17:29:24 Voltage Offset Correction: v_off_ini = -0.000001439 V, v_off_fin = -0.000001468 V 17:29:24 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000355 Vs 17:29:32 Voltage Offset Correction: v_off_ini = -0.000001428 V, v_off_fin = -0.000001780 V 17:29:32 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000331 Vs 17:29:43 Voltage Offset Correction: v_off_ini = -0.000001178 V, v_off_fin = -0.000001117 V 17:29:43 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000329 Vs 17:29:52 Voltage Offset Correction: v_off_ini = -0.000001527 V, v_off_fin = -0.000000970 V 17:29:52 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000381 Vs 17:30:00 Voltage Offset Correction: v_off_ini = -0.000001204 V, v_off_fin = -0.000001189 V 17:30:00 Integrated Voltage Measurement X0 = -0.0005000 m, Delta X = -0.0005000 m VT = 0.000000369 Vs 17:30:00 Integrated Voltage Average and RMS of Measurements X0 = -0.0005000 m, Delta X = 0.0005000 m VT = -0.000000364 +- 0.000000039 Vs 17:30:00 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000000364 +- 0.000000039 Vs BL = -0.00072804 +- 0.00007814 Tm 17:30:00 Integrated Voltage Measurement... 17:30:09 Voltage Offset Correction: v_off_ini = -0.000001190 V, v_off_fin = -0.000001253 V 17:30:09 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001575 Vs 17:30:17 Voltage Offset Correction: v_off_ini = -0.000001336 V, v_off_fin = -0.000001446 V 17:30:17 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001617 Vs 17:30:26 Voltage Offset Correction: v_off_ini = -0.000001380 V, v_off_fin = -0.000001479 V 17:30:26 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001614 Vs 17:30:34 Voltage Offset Correction: v_off_ini = -0.000001325 V, v_off_fin = -0.000001237 V 17:30:34 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001482 Vs 17:30:42 Voltage Offset Correction: v_off_ini = -0.000001594 V, v_off_fin = -0.000001496 V 17:30:42 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001636 Vs 17:30:51 Voltage Offset Correction: v_off_ini = -0.000001441 V, v_off_fin = -0.000001508 V 17:30:51 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001560 Vs 17:30:59 Voltage Offset Correction: v_off_ini = -0.000001213 V, v_off_fin = -0.000001107 V 17:30:59 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001588 Vs 17:31:08 Voltage Offset Correction: v_off_ini = -0.000001294 V, v_off_fin = -0.000001234 V 17:31:08 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001559 Vs 17:31:16 Voltage Offset Correction: v_off_ini = -0.000001400 V, v_off_fin = -0.000001591 V 17:31:16 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001517 Vs 17:31:25 Voltage Offset Correction: v_off_ini = -0.000001351 V, v_off_fin = -0.000001046 V 17:31:25 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001674 Vs 17:31:33 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000000898 V 17:31:33 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001785 Vs 17:31:42 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001342 V 17:31:42 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001573 Vs 17:31:50 Voltage Offset Correction: v_off_ini = -0.000001295 V, v_off_fin = -0.000001717 V 17:31:51 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001485 Vs 17:31:59 Voltage Offset Correction: v_off_ini = -0.000001319 V, v_off_fin = -0.000001386 V 17:31:59 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001564 Vs 17:32:07 Voltage Offset Correction: v_off_ini = -0.000001220 V, v_off_fin = -0.000001130 V 17:32:07 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001424 Vs 17:32:16 Voltage Offset Correction: v_off_ini = -0.000001339 V, v_off_fin = -0.000001338 V 17:32:16 Integrated Voltage Measurement X0 = -0.0010000 m, Delta X = -0.0005000 m VT = 0.000001542 Vs 17:32:16 Integrated Voltage Average and RMS of Measurements X0 = -0.0010000 m, Delta X = 0.0005000 m VT = -0.000001575 +- 0.000000055 Vs 17:32:16 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = -0.000001575 +- 0.000000055 Vs BL = -0.00314913 +- 0.00010939 Tm 17:32:18 Integrated Voltage Measurement... 17:32:26 Voltage Offset Correction: v_off_ini = -0.000001137 V, v_off_fin = -0.000001333 V 17:32:26 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003272 Vs 17:32:35 Voltage Offset Correction: v_off_ini = -0.000001447 V, v_off_fin = -0.000001435 V 17:32:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003227 Vs 17:32:43 Voltage Offset Correction: v_off_ini = -0.000001265 V, v_off_fin = -0.000001400 V 17:32:43 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003360 Vs 17:32:51 Voltage Offset Correction: v_off_ini = -0.000001409 V, v_off_fin = -0.000001355 V 17:32:51 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003257 Vs 17:33:00 Voltage Offset Correction: v_off_ini = -0.000001430 V, v_off_fin = -0.000001321 V 17:33:00 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003307 Vs 17:33:08 Voltage Offset Correction: v_off_ini = -0.000001101 V, v_off_fin = -0.000001181 V 17:33:08 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003300 Vs 17:33:16 Voltage Offset Correction: v_off_ini = -0.000001360 V, v_off_fin = -0.000001366 V 17:33:16 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003264 Vs 17:33:25 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001606 V 17:33:25 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003079 Vs 17:33:34 Voltage Offset Correction: v_off_ini = -0.000001214 V, v_off_fin = -0.000001242 V 17:33:34 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003298 Vs 17:33:45 Voltage Offset Correction: v_off_ini = -0.000001189 V, v_off_fin = -0.000000964 V 17:33:45 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003204 Vs 17:33:53 Voltage Offset Correction: v_off_ini = -0.000001457 V, v_off_fin = -0.000001548 V 17:33:53 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003202 Vs 17:34:01 Voltage Offset Correction: v_off_ini = -0.000001304 V, v_off_fin = -0.000001142 V 17:34:01 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003276 Vs 17:34:10 Voltage Offset Correction: v_off_ini = -0.000001087 V, v_off_fin = -0.000001155 V 17:34:10 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003246 Vs 17:34:18 Voltage Offset Correction: v_off_ini = -0.000001298 V, v_off_fin = -0.000000869 V 17:34:18 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003136 Vs 17:34:26 Voltage Offset Correction: v_off_ini = -0.000001317 V, v_off_fin = -0.000001179 V 17:34:26 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003256 Vs 17:34:35 Voltage Offset Correction: v_off_ini = -0.000001302 V, v_off_fin = -0.000001161 V 17:34:35 Integrated Voltage Measurement X0 = 0.0010000 m, Delta X = -0.0005000 m VT = -0.000003369 Vs 17:34:35 Integrated Voltage Average and RMS of Measurements X0 = 0.0010000 m, Delta X = 0.0005000 m VT = 0.000003253 +- 0.000000050 Vs 17:34:35 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0010000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000003253 +- 0.000000050 Vs BL = 0.00650631 +- 0.00009970 Tm 17:34:35 Integrated Voltage Measurement... 17:34:43 Voltage Offset Correction: v_off_ini = -0.000001256 V, v_off_fin = -0.000001326 V 17:34:43 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002062 Vs 17:34:52 Voltage Offset Correction: v_off_ini = -0.000001257 V, v_off_fin = -0.000001525 V 17:34:52 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002145 Vs 17:35:00 Voltage Offset Correction: v_off_ini = -0.000001400 V, v_off_fin = -0.000001304 V 17:35:00 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002175 Vs 17:35:08 Voltage Offset Correction: v_off_ini = -0.000001344 V, v_off_fin = -0.000001385 V 17:35:08 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002096 Vs 17:35:17 Voltage Offset Correction: v_off_ini = -0.000001267 V, v_off_fin = -0.000001487 V 17:35:17 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002185 Vs 17:35:25 Voltage Offset Correction: v_off_ini = -0.000001208 V, v_off_fin = -0.000001408 V 17:35:25 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002130 Vs 17:35:33 Voltage Offset Correction: v_off_ini = -0.000001368 V, v_off_fin = -0.000001406 V 17:35:33 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002180 Vs 17:35:42 Voltage Offset Correction: v_off_ini = -0.000001288 V, v_off_fin = -0.000001269 V 17:35:42 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002168 Vs 17:35:50 Voltage Offset Correction: v_off_ini = -0.000001465 V, v_off_fin = -0.000001472 V 17:35:50 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002144 Vs 17:35:58 Voltage Offset Correction: v_off_ini = -0.000001254 V, v_off_fin = -0.000001262 V 17:35:58 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002102 Vs 17:36:07 Voltage Offset Correction: v_off_ini = -0.000001099 V, v_off_fin = -0.000000781 V 17:36:07 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002242 Vs 17:36:15 Voltage Offset Correction: v_off_ini = -0.000001086 V, v_off_fin = -0.000001180 V 17:36:15 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002115 Vs 17:36:23 Voltage Offset Correction: v_off_ini = -0.000001322 V, v_off_fin = -0.000001472 V 17:36:23 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002049 Vs 17:36:32 Voltage Offset Correction: v_off_ini = -0.000001274 V, v_off_fin = -0.000001202 V 17:36:32 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002106 Vs 17:36:40 Voltage Offset Correction: v_off_ini = -0.000001481 V, v_off_fin = -0.000001411 V 17:36:40 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002162 Vs 17:36:48 Voltage Offset Correction: v_off_ini = -0.000001108 V, v_off_fin = -0.000000696 V 17:36:48 Integrated Voltage Measurement X0 = 0.0005000 m, Delta X = -0.0005000 m VT = -0.000002224 Vs 17:36:49 Integrated Voltage Average and RMS of Measurements X0 = 0.0005000 m, Delta X = 0.0005000 m VT = 0.000002143 +- 0.000000037 Vs 17:36:49 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0005000 m, dx = 0.0005000 m, Nturns = 1.0 VT = 0.000002143 +- 0.000000037 Vs BL = 0.00428560 +- 0.00007497 Tm 17:36:49 Integrated Voltage Measurement... 17:36:57 Voltage Offset Correction: v_off_ini = -0.000001237 V, v_off_fin = -0.000001158 V 17:36:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000934 Vs 17:37:05 Voltage Offset Correction: v_off_ini = -0.000001397 V, v_off_fin = -0.000001415 V 17:37:05 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000962 Vs 17:37:14 Voltage Offset Correction: v_off_ini = -0.000001513 V, v_off_fin = -0.000001190 V 17:37:14 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000902 Vs 17:37:22 Voltage Offset Correction: v_off_ini = -0.000001358 V, v_off_fin = -0.000001047 V 17:37:22 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000934 Vs 17:37:30 Voltage Offset Correction: v_off_ini = -0.000001308 V, v_off_fin = -0.000001306 V 17:37:30 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000921 Vs 17:37:42 Voltage Offset Correction: v_off_ini = -0.000001199 V, v_off_fin = -0.000001082 V 17:37:42 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = 0.000000001 Vs 17:37:51 Voltage Offset Correction: v_off_ini = -0.000001244 V, v_off_fin = -0.000001284 V 17:37:51 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000885 Vs 17:37:59 Voltage Offset Correction: v_off_ini = -0.000001354 V, v_off_fin = -0.000001500 V 17:37:59 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0005000 m VT = -0.000000893 Vs 17:38:07 Voltage Offset Correction: v_off_ini = -0.000001154 V, v_off_fin = -0.000001210 V 17:38:07 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0005000 m VT = 0.000000980 Vs