SLAC Magnetic Measurements
Date: 01-21-2009
Time: 15:25:21

Project: E163
Magnet Type: PMQ1_blocks
Magnet Name: 1
Serial Number: 
Run Number: 3
Measurement Device: Helmholtz
Operator: sda
Comment: Magnetic moment with arrow on top.   Backing block flipped.

Helmholtz Coil Parameters:
Coil radius, R = 0.493357 m
Number of turns, N = 3045
Geometry factor, G = 1.397540

Magnetic Moment Measurement:
Projection plane: X-Y
Number of measurements for averaging = 4
Magnetic moment strength, M =   1.72396e-06 +-   1.73429e-09 Tm^3
Magnetic moment direction CCW, Theta =  -90.882 +-    0.003 deg
                      
    y   | \          
    ^   |   \        
    |   |     | +th     Mx =  -2.65273e-08 +-   9.26732e-11 Tm^3
    .z  |     | --> x   My =  -1.72375e-06 +-   1.73408e-09 Tm^3
        |     |       
        |   /         
        | /             View From Above

Temperature Measurements:
Helmholtz Coil Thermistor #0, T0 =   20.46 C
Helmholtz Coil Thermistor #1, T1 =   20.40 C