SLAC Magnetic Measurements Date: 08-14-2015 Time: 13:54:56 Project: LCLS Magnet Type: Undulator Magnet Name: Delta Magnet Mode: LPHMF Magnet Kind: 1 Kratio: 0.40 Run Number: 1 Measurement Device: 1wire Operator: sda Comment: Bx 1st and 2nd Integrals along centerline. Delta row values from lin_pol_horiz_field.dat Bx 1st Field Integral Distance the wire was moved = 0.000400 m Number of turns in the wire = 1 Number of measurements for averaging = 6 Main +/- sigma X Y Integral sigIntegral (A) (m) (m) (Tm) -------------+--------- ----------- ----------- ------------+------------ 0.0000 0.0000 0.000000 0.000000 0.000108 0.000010 0.0000 0.0000 0.000000 0.000000 0.000110 0.000008 0.0000 0.0000 0.000000 0.000000 0.000122 0.000019