SLAC Magnetic Measurements Date: 02-22-2006 Time: 14:45:02 Project: SSRL Magnet Type: SkewQuad Magnet Name: BL5 Serial Number: Run Number: 1 Measurement Device: 10 wire Operator: sa Comment: Test w/o ND720 Test Currents (A): 15.0 15.0 14:45:08 Initial Zero Current Measurement, Imag_zero = 0.0000 A 14:45:08 Magnet current ramping to 15.0000 A... 14:45:26 Magnet Current, Imag = 15.1069 A Vtrans = 1.208552 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:45:27 Magnet Current, Imag = 15.1067 A Vtrans = 1.208533 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:45:28 Magnet Current, Imag = 15.1064 A Vtrans = 1.208513 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:45:30 Magnet Current, Imag = 15.1061 A Vtrans = 1.208492 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:45:30 Magnet Current Measurement: Imag = 15.1065 +- 0.0003 A 14:45:30 Magnetic Field Measurement Measuring the magnet strength... 14:45:30 Integrated Voltage Measurement... 14:45:52 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000369545 Vs 14:46:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000440969 Vs 14:46:11 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000388074 Vs 14:46:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000433299 Vs 14:46:30 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000392872 Vs 14:46:39 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000429878 Vs 14:46:49 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000392034 Vs 14:46:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000430630 Vs 14:46:59 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000409663 +- 0.000002558 Vs 14:46:59 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000409663 +- 0.000002558 Vs BL = -0.00409663 +- 0.00002558 Tm 14:46:59 Integrated Voltage Measurement... 14:47:14 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000237345 Vs 14:47:24 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000312602 Vs 14:47:33 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000222548 Vs 14:47:43 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000323412 Vs 14:47:53 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000213578 Vs 14:48:02 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000324009 Vs 14:48:12 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000226497 Vs 14:48:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000310562 Vs 14:48:21 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000271319 +- 0.000002751 Vs 14:48:21 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000271319 +- 0.000002751 Vs BL = -0.00271319 +- 0.00002751 Tm 14:48:21 Integrated Voltage Measurement... 14:48:37 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000107801 Vs 14:48:47 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000151434 Vs 14:48:56 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000120036 Vs 14:49:06 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000138744 Vs 14:49:15 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000130070 Vs 14:49:25 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000132105 Vs 14:49:34 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000130585 Vs 14:49:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000136221 Vs 14:49:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000130875 +- 0.000001599 Vs 14:49:44 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000130875 +- 0.000001599 Vs BL = -0.00130875 +- 0.00001599 Tm 14:49:44 Integrated Voltage Measurement... 14:50:00 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000007628 Vs 14:50:09 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000003264 Vs 14:50:19 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000009383 Vs 14:50:28 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000001842 Vs 14:50:38 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000010389 Vs 14:50:47 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000002250 Vs 14:50:57 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000005073 Vs 14:51:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = -0.000009033 Vs 14:51:06 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000005647 +- 0.000001224 Vs 14:51:06 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000005647 +- 0.000001224 Vs BL = 0.00005647 +- 0.00001224 Tm 14:51:06 Integrated Voltage Measurement... 14:51:22 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000139646 Vs 14:51:32 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000147862 Vs 14:51:41 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000137639 Vs 14:51:51 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000147527 Vs 14:52:00 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000142082 Vs 14:52:10 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000137735 Vs 14:52:19 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000153122 Vs 14:52:29 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000129021 Vs 14:52:29 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000141829 +- 0.000001461 Vs 14:52:29 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000141829 +- 0.000001461 Vs BL = 0.00141829 +- 0.00001461 Tm 14:52:29 Integrated Voltage Measurement... 14:52:45 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000302804 Vs 14:52:54 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000247333 Vs 14:53:04 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000308623 Vs 14:53:13 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000248216 Vs 14:53:23 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000317964 Vs 14:53:32 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000232583 Vs 14:53:42 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000324963 Vs 14:53:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000233330 Vs 14:53:51 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000276977 +- 0.000001826 Vs 14:53:52 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000276977 +- 0.000001826 Vs BL = 0.00276977 +- 0.00001826 Tm 14:53:52 Integrated Voltage Measurement... 14:54:07 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000451423 Vs 14:54:17 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000382714 Vs 14:54:26 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000429291 Vs 14:54:36 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000405114 Vs 14:54:45 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000417504 Vs 14:54:55 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000404263 Vs 14:55:05 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000425365 Vs 14:55:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000400493 Vs 14:55:14 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000414521 +- 0.000002713 Vs 14:55:14 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000414521 +- 0.000002713 Vs BL = 0.00414521 +- 0.00002713 Tm 14:55:24 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00004 0.00001 1 0.13721 0.00047 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 -0.00410 0.00003 -0.00408 -0.00002 -0.0200000 -0.00271 0.00003 -0.00271 -0.00001 -0.0100000 -0.00131 0.00002 -0.00133 0.00002 0.0000000 0.00006 0.00001 0.00004 0.00002 0.0100000 0.00142 0.00001 0.00141 0.00001 0.0200000 0.00277 0.00002 0.00278 -0.00001 0.0300000 0.00415 0.00003 0.00416 -0.00001 14:55:24 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 -0.00410 0.00003 -0.0200 -0.00271 0.00003 -0.0100 -0.00131 0.00002 0.0000 0.00006 0.00001 0.0100 0.00142 0.00001 0.0200 0.00277 0.00002 0.0300 0.00415 0.00003 SL = 0.1372088 +- 0.0004704 Tm^2/m^n 14:55:24 Quadrupole Strength Calculation Check Slope = 0.137209 Tm/m, Inter = 0.000039 Tm, Sig_slope = 0.000345 Tm/m, Est_sig = 0.000018 Tm GL = 0.137209 +- 0.000345 T 14:55:24 Magnet Strength Measurement Harmonic Number = 2 SL = 0.1372088 +- 0.0004704 Tm^2/m^n 14:55:26 Magnet Current, Imag = 15.1008 A Vtrans = 1.208068 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:27 Magnet Current, Imag = 15.1009 A Vtrans = 1.208074 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:28 Magnet Current, Imag = 15.1009 A Vtrans = 1.208071 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:29 Magnet Current, Imag = 15.1009 A Vtrans = 1.208075 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:29 Magnet Current Measurement: Imag = 15.1009 +- 0.0000 A 14:55:29 Magnet current ramping to 15.0000 A... 14:55:33 Magnet Current, Imag = 15.1010 A Vtrans = 1.208081 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:34 Magnet Current, Imag = 15.1009 A Vtrans = 1.208071 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:35 Magnet Current, Imag = 15.1011 A Vtrans = 1.208085 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:36 Magnet Current, Imag = 15.1009 A Vtrans = 1.208071 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 14:55:37 Magnet Current Measurement: Imag = 15.1010 +- 0.0001 A 14:55:37 Magnetic Field Measurement Measuring the magnet strength... 14:55:37 Integrated Voltage Measurement... 14:55:59 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000411888 Vs 14:56:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000407822 Vs 14:56:18 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000413518 Vs 14:56:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000412955 Vs 14:56:37 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000411110 Vs 14:56:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000408430 Vs 14:56:56 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000417083 Vs 14:57:05 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = 0.000407432 Vs 14:57:05 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = -0.000411280 +- 0.000001508 Vs 14:57:05 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000411280 +- 0.000001508 Vs BL = -0.00411280 +- 0.00001508 Tm 14:57:05 Integrated Voltage Measurement... 14:57:21 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000282183 Vs 14:57:31 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000263651 Vs 14:57:40 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000271202 Vs 14:57:50 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000282344 Vs 14:57:59 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000255126 Vs 14:58:09 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000289901 Vs 14:58:18 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000248112 Vs 14:58:28 Integrated Voltage Measurement X0 = -0.0200000 m, Delta X = -0.0100000 m VT = 0.000299509 Vs 14:58:28 Integrated Voltage Average and RMS of Measurements X0 = -0.0200000 m, Delta X = 0.0100000 m VT = -0.000274004 +- 0.000001666 Vs 14:58:28 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000274004 +- 0.000001666 Vs BL = -0.00274004 +- 0.00001666 Tm 14:58:28 Integrated Voltage Measurement... 14:58:44 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000090405 Vs 14:58:53 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000185504 Vs 14:59:03 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000067672 Vs 14:59:12 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000200917 Vs 14:59:22 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000061257 Vs 14:59:31 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000196636 Vs 14:59:41 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000076226 Vs 14:59:50 Integrated Voltage Measurement X0 = -0.0100000 m, Delta X = -0.0100000 m VT = 0.000180430 Vs 14:59:50 Integrated Voltage Average and RMS of Measurements X0 = -0.0100000 m, Delta X = 0.0100000 m VT = -0.000132381 +- 0.000003967 Vs 14:59:51 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = -0.000132381 +- 0.000003967 Vs BL = -0.00132381 +- 0.00003967 Tm 14:59:51 Integrated Voltage Measurement... 15:00:06 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000037189 Vs 15:00:16 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000034579 Vs 15:00:25 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000051828 Vs 15:00:35 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000053986 Vs 15:00:44 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000073079 Vs 15:00:54 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000066144 Vs 15:01:03 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000071293 Vs 15:01:13 Integrated Voltage Measurement X0 = 0.0000000 m, Delta X = -0.0100000 m VT = 0.000055015 Vs 15:01:13 Integrated Voltage Average and RMS of Measurements X0 = 0.0000000 m, Delta X = 0.0100000 m VT = 0.000002958 +- 0.000003396 Vs 15:01:13 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0000000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000002958 +- 0.000003396 Vs BL = 0.00002958 +- 0.00003396 Tm 15:01:13 Integrated Voltage Measurement... 15:01:29 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000197395 Vs 15:01:38 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000092356 Vs 15:01:48 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000178065 Vs 15:01:57 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000114995 Vs 15:02:07 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000168635 Vs 15:02:17 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000113140 Vs 15:02:26 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000176210 Vs 15:02:36 Integrated Voltage Measurement X0 = 0.0100000 m, Delta X = -0.0100000 m VT = -0.000097461 Vs 15:02:36 Integrated Voltage Average and RMS of Measurements X0 = 0.0100000 m, Delta X = 0.0100000 m VT = 0.000142282 +- 0.000003754 Vs 15:02:36 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0100000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000142282 +- 0.000003754 Vs BL = 0.00142282 +- 0.00003754 Tm 15:02:36 Integrated Voltage Measurement... 15:02:51 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000321474 Vs 15:03:01 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000247717 Vs 15:03:11 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000297502 Vs 15:03:20 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000267009 Vs 15:03:30 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000284127 Vs 15:03:39 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000268775 Vs 15:03:49 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000290418 Vs 15:03:58 Integrated Voltage Measurement X0 = 0.0200000 m, Delta X = -0.0100000 m VT = -0.000263831 Vs 15:03:58 Integrated Voltage Average and RMS of Measurements X0 = 0.0200000 m, Delta X = 0.0100000 m VT = 0.000280107 +- 0.000003429 Vs 15:03:58 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0200000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000280107 +- 0.000003429 Vs BL = 0.00280107 +- 0.00003429 Tm 15:03:58 Integrated Voltage Measurement... 15:04:14 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000432684 Vs 15:04:24 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000391628 Vs 15:04:33 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000437762 Vs 15:04:43 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000384065 Vs 15:04:52 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000447155 Vs 15:05:02 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000375837 Vs 15:05:11 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000443879 Vs 15:05:21 Integrated Voltage Measurement X0 = 0.0300000 m, Delta X = -0.0100000 m VT = -0.000386732 Vs 15:05:21 Integrated Voltage Average and RMS of Measurements X0 = 0.0300000 m, Delta X = 0.0100000 m VT = 0.000412468 +- 0.000001696 Vs 15:05:21 Integrated Field Strength, Average and RMS of Measurements X0 = 0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.000412468 +- 0.000001696 Vs BL = 0.00412468 +- 0.00001696 Tm 15:05:31 BL vs X Fit Coefficients: Cn sigCn n (Tm/m^n) ----- --------+-------- 0 0.00003 0.00001 1 0.13765 0.00041 Compute Fit Residuals: X0 BL sigBL BLfit BL-BLfit (m) (Tm) (Tm) (Tm) (Tm) ----------- --------+-------- -------- -------- -0.0300000 -0.00411 0.00002 -0.00410 -0.00001 -0.0200000 -0.00274 0.00002 -0.00272 -0.00002 -0.0100000 -0.00132 0.00004 -0.00135 0.00002 0.0000000 0.00003 0.00003 0.00003 0.00000 0.0100000 0.00142 0.00004 0.00141 0.00002 0.0200000 0.00280 0.00003 0.00278 0.00002 0.0300000 0.00412 0.00002 0.00416 -0.00003 15:05:31 Magnet Strength Calculation Harmonic Number = 2 Number Of X0 Positions = 7 X0 BL sigBL (m) (Tm) (Tm) -------- --------+-------- -0.0300 -0.00411 0.00002 -0.0200 -0.00274 0.00002 -0.0100 -0.00132 0.00004 0.0000 0.00003 0.00003 0.0100 0.00142 0.00004 0.0200 0.00280 0.00003 0.0300 0.00412 0.00002 SL = 0.1376474 +- 0.0004139 Tm^2/m^n 15:05:31 Quadrupole Strength Calculation Check Slope = 0.137647 Tm/m, Inter = 0.000029 Tm, Sig_slope = 0.000445 Tm/m, Est_sig = 0.000024 Tm GL = 0.137647 +- 0.000445 T 15:05:31 Magnet Strength Measurement Harmonic Number = 2 SL = 0.1376474 +- 0.0004139 Tm^2/m^n 15:05:32 Magnet Current, Imag = 15.0995 A Vtrans = 1.207961 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:05:33 Magnet Current, Imag = 15.0996 A Vtrans = 1.207964 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:05:35 Magnet Current, Imag = 15.0996 A Vtrans = 1.207971 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:05:36 Magnet Current, Imag = 15.0996 A Vtrans = 1.207970 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:05:36 Magnet Current Measurement: Imag = 15.0996 +- 0.0001 A 15:05:36 Magnet current ramping to 0.0000 A...