SLAC Magnetic Measurements Date: 11-21-2008 Time: 15:44:15 Project: SSRL Magnet Type: dipole Magnet Name: ECD1 Serial Number: Run Number: 14 Measurement Device: 10 Wire Operator: sda Comment: Test Currents (A): 8.0 8.5 9.0 9.5 15:44:24 Initial Zero Current Measurement, Imag_zero = 0.0000 A 15:44:27 Name = None, is zeroed 15:44:27 Magnet current ramping to 8.0000 A... 15:45:34 Integrated Voltage Measurement... 15:45:36 Magnet Current, Imag = 7.8720 A Vtrans = 0.629761 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:45:45 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005148350 Vs 15:45:54 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005202726 Vs 15:45:55 Magnet Current, Imag = 7.8721 A Vtrans = 0.629766 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:46:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005149535 Vs 15:46:17 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005200590 Vs 15:46:17 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005175300 +- 0.000000238 Vs 15:46:17 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005175300 +- 0.000000238 Vs BL = 0.05175300 +- 0.00000238 Tm 15:46:17 Integrated Voltage Measurement... 15:46:18 Magnet Current, Imag = 7.8720 A Vtrans = 0.629759 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:46:32 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.005677995 Vs 15:46:41 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.005741332 Vs 15:46:42 Magnet Current, Imag = 7.8720 A Vtrans = 0.629764 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:46:51 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.005684390 Vs 15:47:07 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.005738329 Vs 15:47:07 Integrated Voltage Average and RMS of Measurements X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.005710512 +- 0.000000848 Vs 15:47:07 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0900000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005710512 +- 0.000000848 Vs BL = 0.05710512 +- 0.00000848 Tm 15:47:10 Magnet current ramping to 8.5000 A... 15:48:12 Integrated Voltage Measurement... 15:48:13 Magnet Current, Imag = 8.3041 A Vtrans = 0.664328 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:48:27 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005429755 Vs 15:48:36 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005481719 Vs 15:48:37 Magnet Current, Imag = 8.3072 A Vtrans = 0.664577 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:48:46 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005430977 Vs 15:48:54 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005483247 Vs 15:48:54 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005456424 +- 0.000000687 Vs 15:48:55 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005456424 +- 0.000000687 Vs BL = 0.05456424 +- 0.00000687 Tm 15:48:55 Integrated Voltage Measurement... 15:48:56 Magnet Current, Imag = 8.3069 A Vtrans = 0.664553 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:49:09 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.005988365 Vs 15:49:22 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006049469 Vs 15:49:23 Magnet Current, Imag = 8.3072 A Vtrans = 0.664579 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:49:32 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.005999599 Vs 15:49:44 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006046628 Vs 15:49:44 Integrated Voltage Average and RMS of Measurements X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006021015 +- 0.000002098 Vs 15:49:45 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0900000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006021015 +- 0.000002098 Vs BL = 0.06021015 +- 0.00002098 Tm 15:49:48 Magnet current ramping to 9.0000 A... 15:50:50 Integrated Voltage Measurement... 15:50:51 Magnet Current, Imag = 8.9015 A Vtrans = 0.712118 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:01 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005818383 Vs 15:51:10 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005862823 Vs 15:51:11 Magnet Current, Imag = 8.8982 A Vtrans = 0.711852 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:20 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005814102 Vs 15:51:29 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.005883320 Vs 15:51:29 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.005844657 +- 0.000004054 Vs 15:51:29 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.005844657 +- 0.000004054 Vs BL = 0.05844657 +- 0.00004054 Tm 15:51:29 Integrated Voltage Measurement... 15:51:30 Magnet Current, Imag = 8.9011 A Vtrans = 0.712085 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:51:44 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006406501 Vs 15:51:56 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006482557 Vs 15:51:57 Magnet Current, Imag = 8.9009 A Vtrans = 0.712069 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:52:10 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006419009 Vs 15:52:22 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006482053 Vs 15:52:22 Integrated Voltage Average and RMS of Measurements X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006447530 +- 0.000003001 Vs 15:52:22 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0900000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006447530 +- 0.000003001 Vs BL = 0.06447530 +- 0.00003001 Tm 15:52:30 Magnet current ramping to 9.5000 A... 15:53:31 Integrated Voltage Measurement... 15:53:33 Magnet Current, Imag = 9.3424 A Vtrans = 0.747394 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:53:42 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006109386 Vs 15:53:55 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006159126 Vs 15:53:56 Magnet Current, Imag = 9.3417 A Vtrans = 0.747340 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:54:08 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006105944 Vs 15:54:24 Integrated Voltage Measurement X0 = -0.0300000 m, Delta X = -0.0100000 m VT = -0.006168908 Vs 15:54:24 Integrated Voltage Average and RMS of Measurements X0 = -0.0300000 m, Delta X = 0.0100000 m VT = 0.006135841 +- 0.000001585 Vs 15:54:24 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0300000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006135841 +- 0.000001585 Vs BL = 0.06135841 +- 0.00001585 Tm 15:54:24 Integrated Voltage Measurement... 15:54:26 Magnet Current, Imag = 9.3417 A Vtrans = 0.747335 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:54:39 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006762451 Vs 15:54:48 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006810183 Vs 15:54:49 Magnet Current, Imag = 9.3435 A Vtrans = 0.747483 V, Factor V/A = 0.080000 V/A, Zero Current = 0.000000 A 15:54:58 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006746120 Vs 15:55:11 Integrated Voltage Measurement X0 = -0.0900000 m, Delta X = -0.0100000 m VT = -0.006798644 Vs 15:55:11 Integrated Voltage Average and RMS of Measurements X0 = -0.0900000 m, Delta X = 0.0100000 m VT = 0.006779350 +- 0.000006968 Vs 15:55:11 Integrated Field Strength, Average and RMS of Measurements X0 = -0.0900000 m, dx = 0.0100000 m, Nturns = 10.0 VT = 0.006779350 +- 0.000006968 Vs BL = 0.06779350 +- 0.00006968 Tm 15:55:17 Name = None, is zeroed 15:55:17 Magnet current ramping to 0.0000 A...