Voltage drop and individually powered peak field measurements were made on each coil of the Orion ecomp solenoid. Feb-3-2004 sa & kh Volatge drop measurements were made at ~200 A, using a Fluke multimeter. The coils are labeled left and right side 1-4, with 1 being the first coil on each side at the -z end of the solenoid. Left Side Voltage Drops Coil 1 - 1.984 V Coil 2 - 1.980 V Coil 3 - 2.022 V Coil 4 - 2.014 V Right Side Voltage Drops Coil 1 - 2.023 V Coil 2 - 2.022 V Coil 3 - 2.030 V Coil 4 - 2.028 V Peak field measurements using the axial probe with each coil powered at 51.0 A. Left Side Peak Fields Coil 1 - -176.50 Coil 2 - -161.94 Coil 3 - -158.87 Coil 4 - -173.00 Right Side Peak Fields Coil 1 - -174.13 Coil 2 - -166.33 Coil 3 - -156.28 Coil 4 - -170.92