SLAC Magnetic Measurements Date: 04-07-2008 Time: 19:02:43 Project: LCLS Device Type: Undulator Data Type: Serial Number: L143-112000-39 DATASET Number: 3 Tuning Stage: Fine Tuning Run Number: 2 Measurement Type: Long Coil Scans Operator: YL Comment: check Temperature: L143-112000-39:--> top_end 20.04 --> top_mid 20.08 --> top_start 20.09 --> bottom 20.07 --> Air 20.05 --> Granite 20.06 ------------------------------------------------------------- Scan Position Raw value Integral number m Volt*sec T*m -------------------------------------------------------------