Date: Thu, 12 Jan 2006 18:19:27 -0800 (PST) From: Achim W. Weidemann To: "Spencer, Cherrill M." Subject: Second 2 sets of data was/Re: Here is my QE standardization plan-revised! Hi Cherrill, The second two sets of measurements can be found on the web at http://www-group.slac.stanford.edu/met/MagMeas/MAGDATA/LCLS/quad/QE-072/ in the files ending in .r16 (after Usual Standardization) or .r17 (after Standardization 'B') Details below. Cheers, >>>Achim Here is a recap/timeline: -------------------------- 11:49-11:56 Standardized 3x(ramp to 200A, 0A) 'Usual' 11:56 Ramp to 16A,(15.993A) wait. 12:18 Ramp to 0 12:23-12:51 Run 14: 5 measurements at 16 A 'After USUSAL Std.' 13:05-13:07 Standardized 3x(ramp to 25A, 0A) 'Standardization A' 13:07 Ramp to 16A,(15.993A) wait. 13:34 Ramp to 0 13:37-14:05 Run 15: 5 measurements at 16 A 'After Standardization A' --------------- 15:38 Standardized 3x(ramp to 200A, 0A) 'Usual' 15:46 Ramp to 35A,(35.053 A) wait 15:58 Ramp to 0 16:00-16:28 Run 16: 5 measurements at 35 A 'After USUSAL Std' 16:43 Standardized 3x(ramp to 66A, 0A) 'Standardization B' 16:46 Ramp to 35 A,(35.053 A) wait 17:06 Ramp to 0 17:11-1739 Run 17: 5 measurements at 35 A 'After Standardization B' -----------------------------------------------------------------