SLAC Magnetic Measurements Date: 02-25-2019 Time: 08:35:48 Project: LCLS-II Device Type: Undulator Data Type: Serial Number: SXU_020 DATASET Number: 1 Tuning Stage: Tuning Run Number: 15 Measurement Type: Long Coil Scans Operator: YL Comment: tuning endsl; Round 3 Type Position Raw value Integral Nominal Actual Pre-measurement Gap Actual Post-measurement Gap m Volt*sec T*m | T*m^2 Gap US - mm US Raw DS - mm DS Raw US - mm US Raw DS - mm DS Raw --------------------------------------------------------------------------------------------------------------------------------------- I2Y_VS_X 0.000E-03 1.417E-06 68.158E-06 7.20000 9.00005 4389999 9.00000 4391550 9.00015 4389997 9.00005 4391549 I2Y_VS_X 0.000E-03 1.917E-06 92.212E-06 7.20000 9.00040 4389992 9.00025 4391545 9.00040 4389992 9.00025 4391545 I2Y_VS_X 0.000E-03 1.429E-06 68.738E-06 7.20000 9.00050 4389990 9.00035 4391543 9.00055 4389989 9.00035 4391543